HomeMy WebLinkAbout21-1579 i
0
City of Zephyrhills PERMIT NUMBER
--, 5335 Eighth Street
Zephyrhills, FL 33542 BAR-001579-2021
Phone: (813)780-0020
Fax: (813)780-0021 Issue Date: 03/19/2021
Permit Type: Add/Alter (Residential)
Property Number Street Address
1126 21 0010 11200 0040 5661 19Th Street
Owner Information Permit Information Contractor Information
Name: SCARLETT LAWHORNE Permit Type:Add/Alter(Residential) Contractor: HOMEOWNER
Class of Work:Add/Alter Residential
Address: 5901 19Th St Building Valuation:$2,000.00
ZEPHYRHILLS,FL 33542 Electrical Valuation:$1.00
Phone: (813)780-7323 Mechanical Valuation:$1.00 P-41 Z�
Plumbing Valuation:$1.00 (�
Total Valuation:$2,003.00 �l
Total Fees:$75.00
Amount Paid:$75.00
Date Paid:3/19/2021 2:22:34PM
Project Description
LEAN TOO ROOF EXTENTION ADDED TO EXISTING SHED
Application Fees
Building Plan Review Fee $25.00 Building Permit Fee I $50.00
REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c)the
local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or
first reinspection,whichever is greater,for each subsequent remspection.
Notice: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that
may be found in the public records of this county, and there may be additional permit required from other governmental
entities such as water management, state agencies or federal agencies.
"Warning to owner:Your failure to record a notice of commencement may result in your paying twice for
improvements to your property.If you intend to obtain financing,consult with your lender or an attorney
before recording your notice of commencement."
Complete Plans,Specifications add fee Must Accompany Application.All work shall be performed in
accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O.
NO OCCUPANCY BEFORE C.O.
Y/,/�A U
NTRACTO IGNATURE PE VIT OFFICE
I
PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION
CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED
PROTECT CARD FROM WEATHER
813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021
Building Department
Date Received Phone Contact for Permitting
Ownees Name Owner Number 790732-2
ro _3
Owner's Address15l)o i ' i 9W, 5.7L Owner Phone Number
Fee Simple Titleholder Name Owner Phone Numbers i
Fee Simple Titleholder Address
JOB ADDRESS LOT#
SUBDIVISION PARCEL 10#
(OBTAINED FROM PROPERTY TAX NOTICE)
WORK PROPOSED NEW CONITRR ADDIALT SIGN DEMOLISH
e INSTALL REPAIR
PROPOSED USE SFR 0 COMM OTHER
TYPE OF CONSTRUCTION BLOCK CJ FRAME STEEL
DESCRIPTION OF WORK
BUILDING SIZE F SQ FOOTAGE HEIGHT
. . . . . . a . . . . . . . . . . . . . a . . . . . . . N . 85 . 4 . 5 . 8 . . . . . . . . . . . .
NZI)BUILDING ' VALUATION OF TOTAL CONSTRUCTION
2-1 MV I
=ELECTRICAL AMP SERVICE Q PROGRESS ENERGY Q W.R.E.C.
=PLUMBING
=MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION
=GAS Q ROOFING SPECIALTY OTHER
FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES I NO
. . . . . . . . . . . . . . . . . . . . .I. . . . . . . . . . . . . . . . . . . . . . .
BUILDER COMPANY
SIIGNATUR ........... Y/ N I FEE CURREt,
Address License#
ELECTRICIAN COMPANY
SIGNATURE' REGISTERED Y/ N FEE CURREN
Address License#
PLUMBER COMPANY
SIGNATURE REGISTERED Y/ N FEE CURREN
Address License# ll
MECHANICAL COMPANY
SIGNATURE REGISTERED FEE CURREN
Address License#
OTHER COMPANY
SIGNATURE REGISTERED Y/ N_J FEE CURREN LY/N
Address License#
RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction,
Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,StormWater Plans w/Silt Fence installed,
Sanitary Facilities&1 dumpster;Site Work Permit for subdivislonstlarge projects 1,
COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-0-I W Permit for new construction.
Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed,
Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance
SIGN PERMIT Attach(2)sets of Engineered Plans.
*"*PROPERTY SURVEY required for all NEW construction.
. . . . . . . . . . . . . ■ . r . . . . . . . . . . ■ . . . . . . . . . . . . . . . . . . . . . . .
Directions:
Fill out application completely.
Owner&Contractor sign back of application,notarized
If over$2500,a Notice of Commencement Is required. (A/C upgrades over$7500)
Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same
OVER THE COUNTER PERMITTING (copy of contract required)
Reroofs if shingles Sewers Service Upgrades A/C Fences(PlottSurvey/Footage)
Driveways-Not over Counter if on public roadways..needs ROW
813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021
Building Department
NOTICE OF DEED RESTRICTIONS:The undersigned understands that this permit may be subject to"deed"restrictions"which may be more restrictive
than County regulations.The undersigned assumes responsibility for compliance with any applicable deed restrictions.
UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES:If the owner has hired a contractor or contractors to undertake work,they
may be required to be licensed in accordance with state and local regulations.If the contractor is not licensed as required by law,both the owner and
contractor may be cited for a misdemeanor violation under state law.If the owner or intended contractor are uncertain as to what licensing requirements
may apply for the intended work,they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847-8009.
Furthermore,if the owner has hired a contractor or contractors,he is advised to have the contractor(s)sign portions of the"contractor Block"of this
application for which they will be responsible.If you,as the owner sign as the contractor,that may be an indication that he is not properly licensed and is
not entitled to permitting privileges in Pasco County.
TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES:The undersigned understands
that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings,change of use in existing buildings,or
expansion of existing buildings,as specified in Pasco County Ordinance number 89-07 and 90-07,as amended.The undersigned also understands,that
such fees,as may be due,will be identified at the time of permitting.It is further understood that Transportation Impact Fees and Resource Recovery
Fees must be paid prior to receiving a"certificate of occupancy"or final power release.If the project does not involve a certificate of occupancy or final
power release,the fees must be paid prior to permit issuance.Furthermore,if Pasco County Water/Sewer Impact fees are due,they must be paid prior
to permit issuance in accordance with applicable Pasco County ordinances.
CONSTRUCTION LIEN LAW(Chapter 713,Florida Statutes,as amended):If valuation of work is$2,500.00 or more,I certify that I,the applicant,
have been provided with a copy of the"Florida Construction Lien Law—Homeowner's Protection Guide"prepared by the Florida Department of
Agriculture and Consumer Affairs.If the applicant is someone other than the"owner",I certify that I have obtained a copy of the above described
document and promise in good faith to deliver it to the"owner"prior to commencement.
CONTRACTOR'S/OWNER'S AFFIDAVIT:I certify that all the information in this application is accurate and that all work will be done in compliance with
all applicable laws regulating construction,zoning and land development.Application is hereby made to obtain a permit to do work and installation as
indicated.I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all
laws regulating construction,County and City codes,zoning regulations,and land development regulations in the jurisdiction.I also certify that I
understand that the regulations of other government agencies may apply to the intended work,and that it is my responsibility to identify what actions I
must take to be in compliance.Such agencies include but are not limited to:
- Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive
Lands,Water/Wastewater Treatment.
- Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering
Watercourses.
- Army Corps of Engineers-Seawalls, Docks, Navigable Waterways.
- Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment,
Septic Tanks.
- US Environmental Protection Agency-Asbestos abatement.
- Federal Aviation Authority-Runways:
I understand that the following restrictions apply to the use of fill:
Use of fill is not allowed in Flood Zone W"unless expressly permitted.
If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a
"compensating volume" will be submitted at time of permitting which is prepared by a professional engineer
licensed by the State of Florida.
If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall
construction, I certify that fill will be used only to fill the area within the stem wall.
If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent
properties. If use of fill is fqund to adversely affect adjacent properties, the owner may be cited for violating
the conditions of the building permit issued under the attached permit application, for lots less than one (1)
acre which are elevated by fill, an engineered drainage plan is required.
If I am the AGENT FOR THE OWNER,I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to
commencing construction.I understand that a separate permit may be required for electrical work,plumbing,signs,wells,pools,air conditioning,gas,or
other installations not specifically included in the application.A permit issued shall be construed to be a license to proceed with the work and not as
authority to violate,cancel,alter,or set aside any provisions of the technical codes,nor shall issuance of a permit prevent the Building Official from
thereafter requiring a correction of errors in plans,construction or violations of any codes.Every permit issued shall become invalid unless the work
authorized by such permit is commenced within six months of permit issuance,or if work authorized by the permit is suspended or abandoned for a
period of six(6)months after the time the work is commenced.An extension may be requested,in writing,from the Building Official for a period not to
exceed ninety(90)•days and will demonstrate justifiable cause for the extension.If work ceases for ninety(90)consecutive days,the job is considered
abandoned.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR
PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT
FLORIDA JURAT(F.S.117.03
OWNER OR AGEN CONTRACTO
Subscribed and swo o fired) re /�tt& Subscribed an sw r?affirmed)before me this
by BrJ /Ld/ L by r>
Who is/are personally known to me or has/have produced Who is/are personally known to me or has/have produced
as identifi ion. as identification.
Notary Public Notary Public
Commission No. Commission No.
Name of Notary typed,printed or stamped Name of Notary typed,printed or stamped
DISCLOSURE STATEMENT FOR OWNER
CITY OF ZEPHYRHILLS— BUILDING DEPARTMENT
I, 8 1/,f W110 (1/1 have read and fully understand and agree to the
provisions of this instrument.
The undersigned states and affirms that he or she is desirous of constructing, renovating, adding to or
reroofing his or her own domicile, that he or she actually occupies, or will occ py by said
domicile, and same is not for rent, lease or sale. That he or she shall comply with the following
conditions:
1. That the owner and he or she alone shall act as the builder for all phases of construction.
2. That the owner will comply with all provisions of the City of Zephyrhills ordinances and codes
pertinent to the building:
3. That in the event various phases of construction are subcontracted, he will engage only
properly licensed subcontractors and will personally supervise such work.
4. That in the event the Building Inspector shall require corrections to be made, the owner will
assume full responsibility to insure they are made, and upon completion will call for a
reinspection before proceeding with the building. 1
5. That the owner shall assume full responsibility for the construction and will not expect
supervision of his work from the City of Zephyrhills Building Department.
6. That prior to final inspection any additional fees, including reinspection fees, must be paid in
full. A written request from this office shall constitute an official notice to pay additional fees.
7. That the owner shall comply with all City, State and Federal laws in regard to social security,
workman's compensation, lien laws, etc., where applicable.
8. That the owner shall comply with all the safety codes issued by the Florida Industrial
Commission. ! ' `
9. State law requires construction to be done by licensed contractors. You have applied for a
permit under an exemption to that law. The exemption allows you, as the owner of your
property, to act as your own contractor with certain restrictions even though you do not have
a license. You must provide direct onsite supervision of the construction yourself. You may
build or improve a one-family or two-family residence or a farm outbuilding. You may also
build or improve a commercial building, provided your costs dol not exceed $75,000. The
building or residence must be for your own use or occupancy. It may not be built or
substantially improved if for sale or lease, which is a violation of this exemption. You may not
hire an unlicensed person to act as your contractor or to supervise people working on your
building. It is your responsibility to make sure that people employed by you have licenses
required by state law and by county or municipal licensing ordinances. You may not delegate
the responsibility for supervising work to a licensed contractor who is not licensed to perform
the work being done. Any person working on your building who is not licensed must work
under your direct supervision and must be employed by you, which means that you must
deduct F.I.C.A. and withholding tax and provide worker's compensation for that employee, all
as prescribed by law. Your construction must comply with all applicable laws, ordinances,
building codes, and zoning regulations.
OWNER'S SIGNATURE f7f DATE r
ADDRESS f �,LI - 1 t"
PHONE
WITNESS PERMIT
I/Masterforms/OwnersAffidavit/Nov07
• OCCUPANCY GROUP: U
APPROVED PRODUCTS LIST GENERAL NOTES: CONSTRUCTION TYPE: II-B
1. THESE PLANS PERTAIN ONLY TO THE STRUCTURE,INCLUDING MAIN WIND FORCE RESISTING SYSTEM,COMPONENTS AND RISK CATEGORY: II
APPROVAL CLADDING,AND BASE RAIL ANCHORAGE. OTHER DESIGN ISSUES,INCLUDING BUT NOT LIMITED TO PLUMBING,ELECTRICAL,
PRODUCT CATEGORY SUB CATEGORY MANUFACTURER INGRESS/EGRESS,PROPERTY SET-BACKS,FINISH FLOOR ELEVATION AND SLOPE,OR OTHER LOCAL ZONING REQUIREMENTS ARE BUILDING ENCLOSURE TYPE: ENCLOSED
No.& DATE THE RESPONSIBILITY OF OTHERS.
INTERNAL PRESSURE COEFFICIENT: +0.181-0.18
2. THESE STRUCTURES ARE DESIGNED AS NON-HABITABLE UTILITY/STORAGE BUILDINGS CAPABLE OF SUPPORTING DEAD LOAD OF
STRUCTURAL COMPONENTS ROOF DECK CAROLINA CARPORTS,INC. FL6596.1-R6 THE STRUCTURE AND APPLICABLE LIVE AND WIND LOADS. IMPROVEMENTS NOT SPECIFICALLY ADDRESSED HEREIN,INCLUDING WIND EXPOSURE CATEGORY: C
26 Gauge AG Panel 12/15/20 DOORS,WINDOWS,OR OTHER COMPONENTS NOT LISTED IN THE FBC APPROVED PRODUCTS LIST(THIS SHEET),AND NOT
PROVIDED AND INSTALLED BY CAROLINA CARPORTS,INC.,WHICH EXERT ADDITIONAL LOADS ON THE STRUCTURE SHALL BE AT ULTIMATE WIND SPEED(MPH): 141
STRUCTURAL COMPONENTS STRUCTURAL WALL CAROLINA CARPORTS,INC. FL6702.1-R6 THE OWNER'S RISK. BECHTOL ENGINEERING AND TESTING,INC.,SHALL NOT BE RESPONSIBLE FOR STRUCTURAL DAMAGE OR
26 Gauge AG Panel 12/15/2O FAILURE DUE TO THE APPLICATION OF ADDITIONAL LOADS. NOMINAL DESIGN WIND SPEED(MPH): 109
3. ALL STEEL TUBING SHALL BE 50 KSI GALVANIZED STEEL. ALL FASTENERS SHALL BE GALVANIZED OR STAINLESS STEEL. MEAN ROOF HEIGHT(FEET): 10.31
4. ALL COMPONENTS AND CLADDING SHALL BE INSTALLED ACCORDING TO MANUFACTURER'S INSTALLATION INSTRUCTIONS. ROOF ANGLE(DEGREES): 14.0
5. ALL FIELD FRAMING CONNECTIONS SHALL BE#12-14 x 3/4"SELF DRILLING SCREWS WITHOUT CONTROL SEAL WASHER. ALL SHOP DESIGN PRESSURES(PSF):
FRAMING CONNECTIONS SHALL BE WELDED.
ROOF:
6. CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 2500 PSI AT 28 DAYS. THE REINFORCING STEEL SHALL BE ZONE 1: +16.0/-22.9
MINIMUM GRADE 40. CONCRETE SLAB FOUNDATIONS SHALL BE REINFORCED WITH 6X6-W1.4XW1.4 WELDED WIRE FABRIC ZONE 2: +16.0/-32.2
COMPLYING WITH ASTM A 185,OR WITH SYNTHETIC FIBER REINFORCEMENT COMPLYING WITH ASTM C1116. ZONE 3: +16.0/-50.9
DESIGN ROOF PRESSURES: +16.01-28.1
7. CONCRETE ANCHORS SHALL BE TAPCON REDHEAD LDT 1/2"x 5"OR EQUIVALENT OR WEJ-IT ANKR-TITE MODEL AT1252,OR SLEEVE
MODEL HSA 1260,OR EQUIVALENT. WALLS:
ZONE 4: +23.61-25.7
8. POST/RAFTER BRACING: BRACE ON EVERY POST/RAFTER CONNECTION,EXCEPT FOR END WALLS AND GABLE ENDS. ZONE 5: +23.6/-28.7
DESIGN WALL PRESSURES: +23.61.26.6
9. SLAB FOUNDATION SUBGRADE SOILS SHALL BE TERMITE TREATED AND COVERED WITH 6 MIL VAPOR RETARDER PER SECTION
R318.1 OF THE FLORIDA BUILDING CODE SEVENTH EDITION(2020)-RESIDENTIAL,AND SECTION 1816.1 OF THE FLORIDA BUILDING
CODE SEVENTH EDITION(2020)-BUILDING. MINIMUM ALLOWABLE FOUNDATION SOIL CONTACT BEARING PRESSURE OF 2,000 PSF
IS ASSUMED.
10. 14 GA FRAMING: 2-1/2"x 2-1/2"TUBE STEEL(TS)WITH 2-1/4"x 2-1/4"TS NIPPLES.
12 GA FRAMING: 2-1/4"x 2-1/4"TS WITH 2"x 2"TS NIPPLES. ALL WOW ,f
/I AU
CODES Ft0RND CorAPLV wf
EXISTING BUILDING-SWINGING DOOR NOTE: 12 GA �IALLCrRl�tfl�fG e0DF, R Af fNC
EXISTING BUILDING (Behind Lean-To) DfNANC DP NYR ILL
METAL FRAMING AND SIDING PREFABRICATED BY
CAROLINA CARPORTS,INC.
__ _ H
P.O.BOX 1263
DOBSON,NORTH CAROLINA 27017
, y�',
THESE ENGINEERING DRAWINGS ARE TF /�
PROPERTY OF BECHTOL ENGINEERING& (�} +•/ ppp (�
- - = TESTING,INC.AND CAROLINA CARPORT SIN O
THESE DRAWING MAY NOT BE REPRODUCED f " '1„1'+ 1E �'
WITHOUT THE WRITTEN CONSENT OF BECHTOL
ENGINEERING&TESTING,INC.,AND CAROLINAIG
-- - - CARPORTS,INC.
THIS IS TO CERTIFY THAT THE CALCULATIONS AND SPECIFICATIONS
HEREIN HAVE BEEN PREPARED BY THE UNDERSIGNED PROFESSIONAL
ENGINEER,AND ARE IN ACCORDANCE WITH THE REQUIREMENTS OF
FRONT ELEVATION RIGHT SIDE ELEVATION SECTION 1609 OF THE FLORIDA BUILDING CODE,SEVENTH EDITION
SCALE: 118" 1' SCALE: 118"=1' (2020).
GENS�
EXISTING BUILDING `��Q�••"�� c 'C.7JO ��
'7 s
EXISTING BUILDING
BECHTOL ENGINEEftG ATID TEI51IDlN ass.
605 WEST NEW YORK E
DELAND,FLORIDA 32720
(Typical) TE OF
&1'z
Thos Bechtol Sl '• ,, G \\
Florida Licens No.38538i
- f ____________________
1/1/(III '�
PROPOSED UTILITY STRUCTURE
C W 5601 19TH STREET
q I ZEPHYRHILLS, FLORIDA
LEFT I REAR ELEVATION I I " 2/3/2021
SCALE: 118" SCALE: 1/8"=1' BECHTOL ENGINEERING °R"`' MKB °`"'Y NTS
TING;
AND TES Ina
canuiTwc ccrmr"u.omaoHllotru.µo w,,Exuis hsnac warns TB j" '
°' G21001
TB SHEET 1 OF 3
EXISTING BUILDING EXISTING BUILDING
8 z s EXISTING BUILDING-•,
3
5'
4 Maximum
8
10'
9 3 3 5'
8' 7' Maximum
5 4 1 1 1 1 1 1 5 4 1 c)7' 8' 5' 12' — 20'- 12'
32'
FRONT WALL RAFTER/POST FRAMING PLAN TYPICAL INTERIOR RAFTER/POST FRAME SECTION REAR WALL RAFTER/POST FRAMING PLAN
SCALE: 1/8"=1' SCALE: 1/8"=1' (Front View) SCALE: 1/8"=1'
6 q
5' 3 3
Maximum 6-8"
3 1 3 5' 4 1
3 3 3 Maximum 3 3-
30' - - 17 3 10•
EXISTING LEFT SIDE RAFTER/POST FRAMING PLAN EXISTING RIGHT SIDE RAFTER/POST FRAMING PLAN
SCALE: 1/8"=1' SCALE: 1/8-=1'
2-1/4"FOR I 11 11 1 1116rJ
[14
GA
V2""RAMING
GA FRAMING Q�•• ENSF •���
16 GAUGE U-CHANNEL BRACE _ 3853
FASTENED TO THE POST AND 1 _
RAFTER WITH(2)#12-14 x 314"SDF'S
AT EACH END(4 PER BRACE)- STATE OF
,-
5' BRACE SECTION � � • ORP.1D -' \_ `
\\
Maximum Not To Scale // S •• "•• a
E`����
30' PROPOSED UTILITY STRUCTURE
5601 19TH STREET
LEAN-TO SIDE RAFTER/POST FRAMING PLAN ZEPHYRHILLS, FLORIDA
SCALE: 118"=1'
2/3/2021
BECHTOL ENGINEERING I°RA"Tt MKB ° NTS
AND TESTING,Inc.
TB I "°' G21001
cONsuLTRlc 0Eo7Ec"N_k..WRON4[Mu.MD WImAL5 7ESnNo 6NaNCEm
TB I SHEET 2 OF 3
INSTALL 1/2"x MINIMUM 5"TAPCON REDHEAD LDT
ANCHOR OR 1/2"x MINIMUM 5-1/2"EXPANSION
ANCHOR THROUGH BASE RAIL WITHIN 6"OF EACH 6"LONG TS NIPPLE
RAFTER POSTS ALONG SIDES AND EVERY END SECURE POST TO NIPPLE
48"16 GA U-CHANNEL BRACE
WALL POST ALONG END WALL SECTIONS WITH(4)#12-14 x 3/4"SDF's
1 BRACE ANGLE SHALL BE MIN.±45"
4"MINIMUM 2"MINIMUM NIPPLE TO' 3/16"-
- ,Y RAFTER —
_--__-__— MINIMUM 2-1/2"EMBEDMENT TS RAFTER TS RAFTER POST
II ' I'
NIPPLE TO 3/16"
° BASE RAIL
12" g• ° TS CONTINUOUS BASE RAIL
6"LONG TS NIPPLE -
R. SECURE POST TO NIPPLE WITH
--
(4)#12-14 x 3/4"SDF's
12" I i
TS RAFTER POST
MONOLITHIC CONIC.FOOTING(2500 PSI MIN.)
RE D CONCRIETEEBASE RAIL ANCHORAGE POST/BASE RAIL CONN. DETAIL
BOX EAVE RAFTER/POST DETAILCONTINUOUS Not To Scale
I — 2EI Not To Scale
Not To Scale
—TS POST
(12 GA IF ROLL-UP DOOR FRAME)
2"x 2'x 2"16 GA ANGLE CLIP
TS RAFTER POST SECURE TO POST AND TOP OF
TS TRUSSED RAFTER CHORD, HEADER,OR BOTTOM OF WINDOW
OR NON-STRUCTURAL HEADER F RAIUGIRT WITH(4)#12-14 x 3/4"SDF's
TS END POST OR DOOR/ (2)ON TOP OR BOTTOM,(2)ON SIDE
WINDOW FRAME POST
TS BASE/WINDOW RAIL OR AND RAFTER CHORD/RAIL WITH
2"x2"x2"16 GA ANGLE CLIP
SECURE TO POST(EACH SIDE)
1-1/2"x 1-1/2"x 2"16 GA CLIP -
NON-STRUCTURAL HEADER (4)#12-14 x 314"SDFs,(2)ON ANGLE SECURE TO TS NON-STRUCTURAL HEADER
(12 GA IF ROLL-UP DOOR FRAME) TOP OR BOTTOM,(2)ON SIDE • POST AND BASE RAIL 4 (12 GA IF ROLL-UP DOOR FRAME)
WITH(4)#12-14 x 3/4"SDF's,
NOTE: AT ROLL-UP DOOR (2)ON TOP,(2)ON SIDE
OPENINGS,POST SHOULD
BE FLUSH WITH RAIL END. I
CLIP POST TO RAIL ONLY ON TS WINDOW RAIL OR GIRT
SIDE OPPOSITE THE OPENING. FOR VERTICAL SIDING OPTION
TS CONTINUOUS BASE RAIL
POST TO RAIL, TRUSS CHORD, OR
NON-STRUCTURAL HEADER CONN. DETAIL END POST/BASE RAIL CONN _ NON-STRUCTURAL HEADER, WINDOW
Not To Scale f._ 6 � RAIL, OR GIRT TO POST CONN. DETAIL
To Scale
Not To Scale
TS RAFTER POST
—2"x4"16 GA PLATE(ONE REQUIRED)
SECURE TO EITHER SIDE OF NSF 7�i
• POST/RAFTER CONNECTION '• O i
I•• WITH(4)#12-14 x 3/4"SDFs, N •
2"x2"x2"16 GA ANGLE CLIP �(2)ON POST,(2)ON RAFTER� 8538
SECURE TO POST AND TS LEAN-TO RAFTER
RAFTER WITH(4)#12-14 x 3/4"
SDF's,(2)ON BOTTOM, '�
(2)ON SIDE '. STATE OFR �`•�'��
2O"x4"16 GA PLATE 1 i\` •••'•;COQ •• `L/
SECURE TO EACH SIDE OF // s RIDA•,w•`/•���\�
TS END POST POST/RAFTER CONNECTION 2"x2"x2"16 GA ANGLE CLIP /�SAO• �,,`•v\\
WITH(4)#12-14 x 314"SDF's, SECURE TO POST AND
(2)ON POST,(2)ON RAFTER RAFTER WITH(4)#12-14 x 3/4"
SDF's,(2)ON RAFTER,
(2)ON POST
END POST/RAFTER CONN. DETAIL PROPOSED UTILITY STRUCTURE
() Not To Scale 8 POST/ LEAN-TO RAFTER CONN. DETAIL 5601 19TH STREET
�;' Not To Scale
ZEPHYRHILLS, FLORIDA
.1 2/3/2021
BECHTOL ENGINEERING IRAwrc MKB ° NITS
AND TES7MG,Ina
TB 'a G21001
CDNSINWG GEa1ECHNe1L,D(I 04ENIAL.AND W,1FHW5 IES'DNG ENQNE
TB SHEET 3 OF 3