HomeMy WebLinkAbout21-1593 f Q Fr�rrnr!+ t City of Zephyrhills PERMIT NUMBER s � 5335 Eighth Street Zephyrhills, FL 33542 ELCMISC-001593-2021 Phone: (813)780-0020 Fax: (813)780-0021 Issue Date: 03/17/2021 Permit Type: Electric Service Replacement/Misc Property Number Street Address 24 26 21 0110 00000 0070 39910 Dawson Chase Drive Owner Information Permit Information Contractor Information Name: MITCHELL HARTNELL&ANA Permit Type:Electric Service Replacement/M Contractor: SOLAR ENERGY WORLD BEATRIZ ROCHA Class of Work:Add/Alter Residential LLC Address: 39910 Dawson Chase Dr Building Valuation:$27,000.00 ZEPHYRHILLS,FL 33540 Electrical Valuation:$1.00 Phone: (813)528-5883 Mechanical Valuation: Plumbing Valuation: Total Valuation:$27,001.00 Total Fees:$330.00 l / Amount Paid:$330.00 Date Paid:3/17/2021 1:38:45PM Project Description INSTALLATION ROOF MOUNT SOLAR Application Fees Building Valuation Fee $87.50 Electrical Permit Fee $45.00 Electrical Plan Review Fee $22.50 Building Permit Fee $175.00 REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each subsequent reinspection. Notice: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permit required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner:Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing, consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications add fee Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. CONTRACTOR SIGNATURE PE IT OFFICE PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER 813 ado-0ozo.' City of Z,ephyrhills Permit Application Fax-e13-7e0-0021 Building bepartment' '. Date Received. Ph Contact for Permitting I — gal Owners Name Owner Phone Number Y _ Owners_Address�v'�'I1) l:�(�llk)S (� �. Owner Phone Number 77 Fee Simple Titleholder Name_ Owner Phone Number '. Fee Simple Titleholder Address . JOB ADDRESS:. ►1 r(.': LOT#. CA r� .'SUBDIVISION .. ARCEL ID# (OBTAINED FROM PROPERTY'TAX NOTICE)~ WORK PROPOSED NEW CONglk B' ADP/ALT- _ SIGN Q Q. DEMOLISH STALL. REPAIR PROPOSED.USE SFR: ' . 0 COMM" OTHER=' :. TYPE'OF CONSTRUCTION. BLOCK •Q. :_FRAME _ :_STEEL 0 DESCRIPTION OF WORK . . i( ' S!1 ,'-`�/ 'AnC,^eQ ilWQStC,Pe-�A P 'BUILDING SIZE SO FOOTAGE HEIGHT 0 $ • BUILDING AL (� . V UgTION OF.TOTAL CONSTRUCTION .. v =ELECTRICAL $. AMP SERVICE _ '_ PROGRESS ENERGY- = W.R.E.C:, ;=PLUMBING $ 3 ''MECHANICAL' $. - VALUATION OF MECHANICAL INSTALLATION ' =GAS . 0": ROOFING Q:"=SPECIALTY.Q' : OTHER. . �V FINISHED FLOOR ELEVATIONS FLOOD ZONE-AREA =YES _ No -BUILDER : COMPANY . . . . - SIGNATURE. - 'REGISTERED. Y/N "FEE CURREN'. . Y/N .Address License# �f ELECTRICIAN. �'. COMPANY . . SIGNATURES .- - .''..REGISTERED -I ,Y/N FE C RREN Y/N - Address License# wo*1 3 -33b1� . . PLUMBER .. COMPANY' .. SIGNATURE ...REGISTERED. .Y/N .FFr CURREN .'Y/N. - Address'.. License#„ MECHANICAL . COMPANY .. SIGNATURE .- . .- - . . .REGISTERED Y/N "''FEE CURREN - 'Y/N• - - - . Address .. :License# OTHER:- L COMPANY U6 r•.(✓. ( y l . ... SIGNATURE" ' .. - -" "'REGISTERED.' . Y!N FEE CURREN Y/N .. .. �-1 .. Address r *mil; Q. License# V ' 7 Q. Ef.[[i.[.E■5■i[[■:[ .[[E [[ [:[ [_Inall-a.[[. ■[[■7:124■[.[[[[ l ,[_[[Ean-[ E[[ [:.[ [E[I[,[/[1. .' :. RESIDENTIAL ' 'Attach(2)Plot Pians;'(2)sets of Building Plans;(1)set,of Energy Forms;R-O-W'Permit for new'construction; Minimum ten(10)working days after submittal date:Required onsite,Construction Plans,Sto_6w'ater Plans w/Si(t.Fence installed,. Sanitary.Facilities&1 duimpster,Site Work Permit for subdivislons/large projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;.(1)set of Energy Forms.R-0 W Permit for new Construction. Min(mum ten'(10)working days after submittal date.Required onsite;Construction Plans,Stomiwater plans W/Si(t.Fence installed, Sanitary'Facilities&4 dumpster.Site Work Permit for all new projects:All commercial requirements must meet compliance SIGN PERMIT. . Attach(2)sets of Engineered Plans: ""PROPERTY SURVEY required for all NEW•constuction. Directions:. Fill out application completely. Owner&Contractor sign back of application,notarized _ _If over$2500,a Notice of Commencement Is required:(AlC-upgrades over$Mlle) Agent(for the contractor)or Power of Attomey(for the owner)would-be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) 'Reroofs if shingles Sewers Service Upgrades rades A/C 'Fences PloUSurve/Foote e 9 .. (. .. . Y 9 ) Driveways=Not over Counter if on public.roadways..needs ROW :. 1313-780-Ub20 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department NOTICE OF DEED RESTRICTIONS:The undersigned understands that this permit may be subject to"deed"restrictions"which maybe more restrictive than County regulations:The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES:If the owner.has hired a contractor or contractors to undertake work,they may be required to be licensed in accordance with state and local regulations.If the contractor is not licensed as required by law,.both the owner and contractor may be cited for misdemeanor violation under state law.If the owner or intended contractor are uncertain as to what licensing requirements- may apply for the intended work;they are.advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847-8009. ' Furthermore,'if the'ownerhas hired a contractor or contractors,he is advised to have the contractors)sign portions of the"contractor Block"of this. applicationfor which they will be responsible.If you,as the owner sign as the,contractor,that may be indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND-RESOURCE RECOVERY FEES:The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to'the construction of new buildings,change of use in,existing buildings,or expansion of existing buildings,as specified in Pasco County Ordinancer number.89-07 and 90-07,as amended.The undersigned also understands,that . such fees,as may be due,will be identified at the time of permitting.It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a"certificate of occupancy"or final power release.If the project does not involve a certificate of occupancy or final power release,the fees must be paid prior to permit issuance.Furthermore;if Pasco County Water/Sewer Impact fees are due,they must be paid prior 'to permit issuance in accordance.with applicable Pasco County ordinances., 'CONSTRUCTION LIEN LAW(Chapter 713,Florida Statutes,as amended):If valuation of work is$2,500.00 or more,I certify that I,the applicant, have been provided with a copy of the"Florida Construction Lien Law—Homeowners Protection Guide°prepared by the Florida Department of Agriculture and Consumer Affairs.If the applicant is someone other than the"owner',I certify that I have obtained a copy of the a above described document and promise in good faith to deliver it to the"owner"prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT:I certify that all the information in this application isaccurate and that all work will be done in compliance with all applicable:laws regulating construction,zoning and land development.Application is hereby made to obtain apermit to do work and installation as indicated.I certify'that no work or installation has commenced prior to issuance.of a'permit and that all.work will be performed to meet standards of all laws regulating,construction,:Countyand City codes,zoning regulations,and land development regulations in the jurisdiction.,I also certify that I understand that the regulations of other government agencies may apply to the intended work;and that it is my responsibility to identify what actions I must take to be in compliance..Such agencies include but are not limited to: - . Department of.Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive- Lands,WaterMastewater Treatment.. Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses: - . Army Corps of Engineers-Seawalls,Docks,-Navigable Waterways. - Department of,'Health & Rehabilitative'Services/Environmental Health Unit-Wells, Wastewater Treatment,.. Septic Tanks: US Environmental Protection Agency-Asbestos.abatement. Federal Aviation Authority-Runways. l.undenitand that the following restrictions apply to the use of fill: - Use of fill is not'ailowed In Flood Zone W"Unless expressly permitted.. - If the fill material is to be used in Flood Zone "A it is. understood_that a drainage plan_addressing a "compensating volume"will,be submitted at time of permitting which is prepared,by a professional.engineer licensed by the State of Florida. - If.the fill,material-is to be used in Flood Zone "A" in connection With a permitted building using stem wall construction,I certify that fill will be used only to fill the area within the-stem wall. If fill material is to be used in any area, I certify that use.of such fill will not adversely affect adjacent properties.If use of fill,is found to adversely affect adjacent properties, the owner may be cited'for violating the conditions of the building permit issued under the attached-permit application,for lots less than one.(1) acre which are.elevated by fill,an engineered drainage plan is-required. If I am the AGENT FOR THE OWNER,I;promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing'construction.I understand that'a separate permit may be required'for electrical work,plumbing,signs,wells;pools,air conditioning,gas,or other installations'not specifically included in the application.A permit issued shall be,construed to be a license to proceed with the work and not as authority to violate,cancel,alter,or set aside any provisions of the technical codes,nor shall issuance of a'permit prevent the Building Official from thereafter requiring a correction of errors in plans,.construction or violations of any codes.Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance,or if work authorized by the permit is suspended or abandoned for a. period of six(6)months after the time the work is commenced.An extension may be requested,in writing,from the Building Official for a-period not to exceed ninety(90)days and will demonstrate justifiable cause for the extension.If work ceases for ninety(90)consecutive days,the job is considered abandoned. WARNING TO-OWNER:'YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENTMAY RESULT. IN YOUR PAYING.TWICE FOR-IMPROVEMENTS TO YOUR PROPERTY:IF YOU-INTEND-TO OBTAIN FINANCING,.CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT, FLORIDA JURAT(F.S.11L.p3) OWNER ORAGENT- CONTRACTOR *su !;rnl and swom t (or affirmed)before"me this bsc d swo��or a irtned)befonby I -nd)(AV Z r so �1IX kn99wn to me or has/have produced is/ re er�ona y two n tome o as/ ave produced '!( as identification. 9�- as'identification. Notary Public Notary Public Com 'ssion No. t/ Commi sion No. - ,. . Name of Notary typed,printed or stamped Name of Notdry typed,printed or.stamped- ALICE ANDRADE ��!;VP;/4.,;; ALICE ANDRADE '.'Notary Public-State of Florida ••� . Notary.Public-State of Florida Co�rtmission#GG,945509 Commission#GG 945509 My Commission Expires '•. r •� My Commission Expires January 08, 2024 January 08,2024 rrrr�t` INSTR#2021028734 OR BK 1 0278 PG 415 Page 1 of 1 02/11/2021 11:46 AM Rcpt:2260243 Rec: 10.00 DS:0.00 IT:0.00 Nikki Alvarez-Sowles, Esq., Pasco County Clerk&Comptroller Permit No. PIMIIDNo T 1-OI10'00000-00-7 0 NOTICE OF COMMENCEM T Stateof W Countyof�() THE UNDERSIGNED hereby gives notice that Improvement will be made to certain real properly,and In accordance with Chapter 713,Florida Stande% the foDawing bdormallon Is provided In this Notice of Commencement: 1. Description of Properly: Parcel ldenti loaflon No. 44 10'000 00-00-70 Street Address:�'IA0110 Dawmn O.1/I - t)f. ?WhYrki1 0- .3.3 54D 2 GenerelDesWptionoflmprovemeM lnr4atlina 06,F SAW ftu& 3. Owner Information or Lessee Information V the lasses contracted for the improvement: Dili kAw l �4a' - a t l :5�0110 J!JuDsbet C0 �tZ� CRYp nhurYi�ll� Interest In Property: Name of Fee Simple Titleholder. 1`1 lW War Of different from Owner listed above) �Lilt AddreContractor m _ yalV j f�"1sy sla 4. 'Addressy ��!. S� V �Y1 I�I C�/„g?yei State Contractor's Telephone No- R(J�'1� / I f T 5. Surety: � )jo- _ Name 1�1! — city Amoursrtt of Bond: S n��1✓"� Telephone No.: w state 6. Lender. Vella Name 1`� ! Address �" city ` state Lenders Telephone No.: 7. Persons within the State of Florida designated by the owner upon wham notices or ether documents may be served as provided by Section 713.13(1)(a)(7),Flatda statutes: Name N i� v�lw- Address ��'A City state IFS Telephone Number of Designated Person: a. In addition to hlmself, owner designates K)11d el— m s to receive a copy of the Lmnors Notice as provided In Sedan 713.13(1)(b),Florida Statutes. Telephone Number of Person or Entity Designated by Owner. IA 9. ExpIre6on data of Notice of Commeneemerd(the expiration dam may not be before the completion of construction and fatal payment to the contractor,but will be one yearfrom the date of recording unless,a different date Is spedfied): WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT RRESUL IINIYOURR PAYING TVNCE FO IRIMMPRNOVEMENCTS TOYOURPA 1, SEC1 ANN 10TIC9 OFOCOMMENCEMENT MS BEBE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION.IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. Urrder penelry of per)ury 1 declare that 1 have read the foregoing notice of commencem nt and that the fads stated therein are true m the best of my Inowmdga and bebaf. STATE 0 COUNTY P ALICE ANDRADE NOtaryPUblic-State OfFtOfldo SlgewreorowrarorL.s:..,orownersorLassee'sAuthodzed e e Commission M GG 846608 t„itcer/Director/PadneNManager My Commission Expires n( -�/ January 08.2024 ignato aTRWOffice The foregoing ant was acknowledged fore me this day as (type of authority,a g.,officer,trustee,attorney in fact)for (name y of ehalf of Jo IrL nstnanerd was enacted). Parsonatly Known❑2$Produced Iderdificatla I-, Notary Slgnatrae Type of IdeMlicallon Produced L J�1 Vf�.fI (.1 0 Name(Print) j wpdataftWnotleeoommeneemonLp W53048 Data Sheet Enphase Microinverters Region:AMERICAS T Enphase Enphase Q 7 Micro" and Enpiiase.IQ 7+ Micros" IQ-:7. •an. � I Q..7+ dramatically,simplify the.installation.process while • achieving the highest system efficiency. M icro nvet ers Part of the:Enphase.IQ Syst er1i,the.IQ 7:and IQ 7+ Microinvertersintegrate with the Enphase voyTM, Enphase IQ Battery."",-and the.Enphase.. IQ En . ten"" 'Moni toring nitoring and analysis software: . IQ Series Microfnverters extend the reliability standards set-forth:by previous,generatibris,and - ing, . . undergo over a.million.iiours of power on test enabling Enphase to proVide.an.'industry.- leading warranty.of up:to 25 years Ea sy Install.: •. Lightweight and simple. - I Faster installation with•mproved lighter two=wire cabling . Built-in rapid shutdown.compliant(NEC 2014&2017) Productive,and.Reliable .optimized for high powered,607cell and 72-cell*modules More than amillion hours of testing Class II double-insulated enclosure UL listed m Smart Grid Ready :. - Complies.with.advanced grid support,voltage and 'frequency ride-through requirements Re motely updates to respond to changing;. grid requirements . . Configurable for-varying grid profiles • Meets CA Rule 21 (U 1L 741-SA).' *The IQ 7+Micro is required to support 72-cell modules. ENPHASE. TOearn more about Enphase:offerings,visit enphasexorri V. . . . .Enphase IQ.7 and IQ 7+ Microinverters INPUT DATA(PC) IQ7-60-2-US IQ713LUS=72-2-US Commonly used module pairings' 235 W-350 W+ 235 W-440 W+ Module compatibility, 60-cell PV modules only 60-cell and 72=cell P.V modules Maximum input DC voltage 48 V 60 V Peak.power tracking voltage 27 V_-37 V 27 V-45 V Operating range 16 V-48 V 16 V-60 V Min/Max start voltage 22 V/48 V 22 V/60 V Max DC short circuit current(module Is_c) 15 A 15 A Overvoltage class DC port II II D.0 port backfeed current 0 A 0 A PV array configuration' 1 x 1 ungrounded array;.No additional DC side protection required; AC side protection requires max 20A per branch circuit. OUTPUT DATA(AC) IQ 7 Microinverter IQ 7+Microinverter Peak output power 250 VA 295 VA ' Maximum continuous output power 240 VA 290 VA Nominal(L-L)voltage/range2 240 V/ 208 V/ 240 V% 208 V% 211-264 V 183-229 V 211-264 V 183-229 V Maximum continuous output current . . 1.0 A(240 V) 1,15 A(208 V) 1,.21 A(240 V) 1.39 A(208 V) Nominal frequency 60 Hz 60 Hz Extended frequency range 47-68 Hz 47-68 Hz AC short circuit fault current over 3 cycles 5.8 Arms 5.8 Arms Maximum units per 20 A(L L)branch circuit' _ 16:(240 VAC) 13(208 VAC) -13(240 VAC) 11 (208 VAC) ;.Overvolta e class AC port III III AC port backfeed current 0 A 0 A Power factor setting 1.0 1.0 Powerfactor(adjustable),. 0.85 leading...0.85 lagging :, : . . 0.85leading_.0.85lagging EFFICIENCY. @240 V @208.V @240 V . @208 V Peak.efficiency 97.6% 97.6% 97.5% 97.3.% CEC weighted efficiency. 97:0°i 97.0% 97.0°i 97.0°i 'MECHANICAL DATA Ambient temperature range -40°C to+65°C Relative humidity range 4%to-T00,%(condensing) " Connector type(IQ7-60=2-US&IQ7PLUS-72-2-US) MC4'(orAmphenol H4 UTX with additional Q-DCC-S adapter) Dimensions(WxHxD) 212 mm x 175 mm x;30.2 mm(without bracket) . Weight 1.08 kg(2.38 Ibs) Cooling Natural convection-No fans Approved for wet locations Yes - Pollution degree PD3 Enclosure Class II double-insulated,corrosion resistant polymeric enclosure Environmental category/UV exposure rating NEMA Type 6/outdoor FEATURES. Communication Power Line Communication'(PLC) Monitoring Enlighten Manager and,MyEn lighten.monitoring options: Both options require installation of an Enphase IQ Envoy: . Disconnecting means The ACJancl DC connectors have been evaluated and approved by UL for use as the load break disconnect required by NEC 690. Compliance CA Rule 21 (UL 1741-SA) . UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B, ICES-0003 Class B,. CAN/CSA-C22.2 N0.107.1=01 This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and. NEC=2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of.PV Systems,for AC and DC conductors,when installed according manufacturer's instructions. 1.No enforced DC/AC ratio.See the compatibility calculator at htt 'sp //enohase.com%en-us/suppdrt/module-compatibility. 2.Nominal voltage range can be extended beyond nominal if required by the utility. 3.Limits may vary.Refer to local requirements to define the number of micro inverters per branch in your area: To learn more about Enphase offerings,visit enphasexom .,,, E NPHASE. '@'2019 Enphase.Energy+'All rights reserved:All trademarks or brands used are the.propeity of Enphase Energy,Inc: 2019-3-26, . powered by.. . DUO 0 EAK DU'O BLK=G5',,300-w32 Q. AR MODULE The new.QTEAK DUO BLK=G5 solar module from Q CELLB impresses-with'' its 'outstanding-visual appearance and particuiarly .high. performance: on_a.small:surtace thanks to.the..innovative.'Q.ANTUM DU.O Technology: Q:ANTUM's world=record-holding�cell:concept.has now-been combined with'state-of-the=art.circuitry. half•cells .and.a six=busbar.design::thus' :- :: achieving 'outstanding"performance under real..conditions both.With low-intensity.solar radiation as well as onhot,, .clear summer days. Q ANTUM.TECHNOLOGY:LOW.LEVELIZED COST OF ELECTRICITY. Hi her. > g :yield per surface area, lower BOS costs, higher-power classes;and an.efficiency rate of up to 19.3%. INNOVATIVE ALL-WEATHER;TECHNOLOGY.lei . Optimal yields,,whatever the weatherwith excellent low=light and.temperature behavior. ENDURING.HIGH PERFORMANCE . . Long-term yield security with Anti LiD jechnology, . , . 0CELLS. ' 111 .�, -Anti PID Technoiogy', Hot-Spot Protect.and:Traceable QualityTra,QTm. ,TOPawANDvv_ i�.Eooie EXTREME"WEATHER RATING High-tech aluminum alloy frame;certified for high snow. . Z 18 . (5400Pa).and wind loads(4000Pa)regarding.lEC: A.RELIABLE INVESTMENT ■ Inclusivej?- ear roductwarrantyand_25-year. .. . . y P _ - .Quality Tested bM linear performance guarantee2. 03 2587 OfSTATE OF THE ART MODULE TECHNOLOGY. Q.ANTUM DUO combines cutting edge cell separation ' and innovative wiring,with Q.ANTUM Technology: 1_'APi test conditionsaccoraingto IEWS 62804-1:2015; . method B( 1500V,168h) 2.See data sheet on'rear for,further THE IDEAUSOLUTION FOR;NNW information ' Rooftop arrays on � residential buildings Engineered•iri.Germany . . MECHANICAL 1 Format 66.3in':x 39.4in x_1.26 in(including frame) °aw m iS 1iw7w ,zr a>z�w• .(1685 mm x 1000 minx m x 32r Weight .41.2lbs"(18.7kg) Front Cover 0,13 in.0.2 mm)thermally pre=stressed glass with anti-reflection technology Back Cover Composite film 37-(951� Frame Black anodized.aluminum. •a, ® pv."` � Cell 6 x 20.monocrystalline Q.ANTUM solar half-cells Junction box" 2,76=3.35 in x 1.97-2.76 in x 0.51-0:83 in (70-85mm x 50=70mm x 13-21mm),decentralized,IP67 y 4•W (°RuLN '•0i�"A" Cable 4mm2 Solar cable;(+)t43.3in(1100mm),(=)a43.3in(1100mm) '. -Qlosir�esnm Connector Multi-Contact MC4,IP68 °�su<•SmmI -- ELECTRICALCHARACTERISTICS POWER CLASS 300 305 310 315 .320 MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS,STC'(POWER TOLERANCE+5 W/:-C W) Power at MPP' Pw. [W] 366 - . 305 310. 315 320 Short,Circuit'Current': Isc 141 .9.72 9.78 9.83 9.89 9.94 Open Circuit Voltage' V.C. IV] 39.48 39.75 40.02 40.29 40.56 g 'Current at MPP. IYPP [A] 9.25 9.31 9.36 9.41 9.47' Voltage at MPP VM;P IV]' 32:43' 32.78 33:12 33.46 33.80 Efficiency' 0 [%] ' 217.8 218.1 218.4 z 18.7. 219.0 MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS,NMOT' - Power at MPP PAP. [W] _ 224.1 _ 227.8 231.6 235.3 239.1 E . Short.Circgit Current Is°- [A] 7.83- 7.818, 7.92 . 7.97 8.01 -. E • 'Open Circuit Voltage V 37.15 _ 37.40 371.66 37.91,• 38.17 AE Current at MPPI ,eP [Al 7:28 7.32 7.37 7:41 7.45 Voltage at MPP V,,' [V1 30.78. 31.11 31.44 31.76 32.08 'Measurement tolerances.!`„,t3%;Ix,Vo°t5%at'STC:106OW/m2,25s2°C,AM 1.5G according to IEC 60904-3-'800 W/m2,NMOT,spectrum AM 1.5G - 6 CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE . y-ioo h ii - . .__T__--_T__,__At least98%of nominal power during first year. a?.reafter max 0 54%a--------- The degradation per year. At least93.1%ofnominalpowerup.tol0.years. W g At least 85%.of nominal power up to 25 years. W All data within measurement tolerances. '-= --==- --==.-,---==-�--__-j P- u Full warranties in accordance with the warianty terms of the Q CELLS'sales organization'of your .. respective country. 20° aaa eao ,000 - - - .INRAOIANCE[W/m'1 �s,dw em bi,�.s.am.for o 2u a reeRs Typical module performance under low irradiance conditions in u,.nymP.�,�u,.4ir ?,.m•.sw�po comparison to STC conditions'(25°C,1000W/m2). TEMPERATURE COEFFICIENTS o . Temperature Coefficient of Is° a.. [%/Kl .+6.04 :.Temperature Coefficient;of Vo° p -0.28. o , Temperature Coefficient of P,,P. . . y [%/K] -0.37 ..Normal Operating Module Temperature NMOT . ['F] 109 t5.4(43 t3°C) PROPERTIES1' I m 0 Maximum System Voltage Vs, [VI 1000(IEC)/1000(UL). Safety Class II Y . Maximum Series Fuse Rating. [A DC] 26 Ffre Rating. - C(IEC)./.TYPE.1.(UL.) - a Max.Design Load,Push/Pull(UQY [Ibs/ff'] 75(3600 Pa)/55(2667.Pa). _Permitted module.temperature', -40"F up to+185°F on continuous duty' (-40°C up to+85°C) Max.Test Load;Push/Pull(UL)2 [Ibs/ft?] 113(5400 Pa)/84(4000 Pa) a see installation manual QUALIFICATIONS AND CERTIFICATES PACKAGING INFORMATION UL 1763;.VDE Quality Tested;CE-compliant; - Numherof Modules perPallet 32 IEC;61215:2016;IEC 61730:2016;Application class A . . -: - Numberof Pallets per 53'Trailer. 30. - S Number of Pallets per 40'High Cube Container. ' 26 s wE. C E `�� Pallet Dimensions(L x W.x.H) 69.3in x 45.3in x 46.9in C v.d US °„7°° (1760mm x 1150mm x'119.O.mm) Pallet Weight 1415lbs(642kg) NOTE:.Installation instructions must be followed.See the installation and operating manual or contact our technical service department for further information on approved installation and use ' of this product. "" H Hanwha Q CELLS America Inc. 300 Spectrum Center Drive,Suite 1250,Irvine,CA 92618,USA I TEL+1 949 748 59.96 1 EMAIL Inquiry®us.q-cells.com I WEB www.q-cells.us _ , ShOpNrdt1c Solar Mounting.Solutloes, SpeedSealT"' Foot Training Guide - Standard Composition Overview,. . .This training .guide outlines.best:practices. fo.r installing th.e.-SDeedSealT ' foot . fleshless sealing L Foot on composition shingle roofs. This -Guide is meant to supplement the-,Ultra Rail -Installation Manual 'and provide :detailed instructions :on installation .practices that.produce high.-quality systems-and maintain construction efficient-y: The target,audience of.this guide is exp.erience.d rooftop �ol 'r installers.. . with a strohg:under'sta.nding of sol,ar:constructi_on :best pra.ctices;.an:d a basic und.erstarnding of:the.Ultra Rail mounting system; Reglui:red:Tools 0'Drill With 3/16„ Pilot..DriIC Bit .'. 0. caulking,Gun with approved Roof.Sealant :.0 Impact.Driver.with Socket . Component Details.". SpeedSeaITM.Foot 5/16" Sealing.Lag Screw _ SpeedSea ITm Foot Installation • La out S Y peedS_ealTM Foot locations on roof .and:_ma:rk locations:.for fasteners usin marking crayon or chalk based .on rafter. :lo.cation an.d these rules: 1a- Pilot hole should be. located 1.5�3" from the bottomed of shingle course above 2) :SpeedSealT`" Foot.should never be installed acrostjwo shingle courses SpeedSealtAi:Fdot.may be instidled over the vertka!seam= . _ . between singles.in.the same row. ur►. z :Vsing locations draws on roof during .system layout, .drill a 3/16 pilot hole into .roof : fram member: . • Remove any. dirt or: debris #rom_roof _ rfade and properly seal :any .missed pilot holes :with a flashing .card before SpeedSea.IT'" :Fo:ot is :installed.:: Turn ..Sp.eedSea1T'" 1=oot over and apply. roof . . . seaaant, filling •the cavity formed. by the'. sealant .ring. . . 2 Attach. SpeedSea:ITm' Foot to roof using ® .. *' f a 5/16" sealing .lag screw. Drive the lag screw into the pilot hole and- rafter fora .. - �31iy� recommended minimum -2-1/2" embedment .. ;'.�ajz_aL�=R:#+'- , A:JR"c6?ff•-�v,;"�y4i±'i�':, - -As-the lag screw is- being driven into the u derside _F roof; watch rubber gasket on n of se.alin.g washer for compression. Stop driving the lag screw when the-gasket becomes visible. around the edge of the washer: . ay TL t S_ �,�u J), w�:�Tl �1-'�i{;frjr Over tightening the lag screw will damage the rubber gasket. .As SpeedSealT". Foot it tightened to the roof sealant will ooze from the, Lower cavity of the. L Foot as an indicator-of proper sealing: If_no sealant is seen, remove SpeedSealT"' Foot .from roof and add more sealant before reinstalling. Sp.ee.dSe.alTm Foot .is now. ready for the remaining Ultra Rail a.nd. . module: installation. Notes: 877-732-2860 www.snapnrack.com contact@snapnrack.com ©2020 by SnapNrack Solar Mounting Solutions.All rights reserved 3. JAMES A. CLANCY PROFESSIONAL ENGINEER 601 ASBUR Y AVENUE NATIONAL PARK, NJ 08063 (856) 358-1125 FAX: (856) 358-1511 Construction Code Office Date: February 18,2021 Re: Structural Roof Certification Subj: Hartnell Residence,39910 Dawson Chase Dr.,Zephyrhills FL 33540 We have provided a review of the house roof constriction of the above named property in regards to verifying the capacity of the existing roof for installation of a new Solar Panel Array. We have found the residence to be of wood frame construction bearing walls with a truss framed roof system. The roofs are of 2x4 @ 24" o.c. trus5k and is sheathed with 1/2" ext-ply sheathing and a single layer of asphalt shingle roofing. The wood framed roof structure bears directly upon the framed exterior wall system. The wood framed roof structure bears directly upon the framed exterior wall system. The existing members meet FRC- 2017 and IRC-2017 design span ratings with sufficient capacity to carry the 4#/sf additional load imposed by the proposed solar array per the details below: Per FL stature 377.705 (revised 7/1/2017) I, James A Clancy PE#64848 licensed pursuant to chapter 471, certify that the PV electrical system and electrical components are designed using the standards contained in the most recent version of the Florida Building Code. Installation of solar rack systems shall be as follows: Each panel row shall be supported upon 2 mounting rails. Rails shall be screw anchored through roof and directly to rafters or purlins.below. Rail attachment points to rafters shall be staggered each row with exception to the first fastener row from the gable end which is attached to two adjacent rafters/trusses with Stainless Steel fasteners. Rail attachment to roof shall be fastened 24"o.c.at corners and 48"o.c.through the field. Rails are to be placed at 24-48"o.c.on the roof. Solar panel mounting systems installed parallel to the plane of a roof shall be no more than 12"above the roof when measured perpendicular to the roof surface. When installed per the above specifications the system shall meet the required 145 MPH wind load and 0 PSF ground snow load requirements. Should you have any further questions or comments please feel free to contact our office. Respectfully, �.,a�� James A. Cl Professional n to FL License 6 4 �Q�•. cTATE GF • 1 i