Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
21-1611
1 � Q riu�+rirn City of Zephyrhills PERMIT NUMBER - 5335 Eighth Street Zephyrhills, FL 33542 ELCMISC-001611-2021 ' Phone: (813)780-0020 Fax: (813)780-0021 Issue Date: 03/17/2021 Permit Type: Electric Service Replacement/Misc Property Number Street Address 12 26 210310 00000 0580 39435 8Th Avenue Owner Information Permit Information Contractor Information Name: ERIC VEGA ALVAREZ Permit Type:Electric Service ReplacemenVM Contractor: SOLAR BEAR LLC Class of Work:Add/Alter Residential Address: 39435 8Th Ave Building Valuation:$0.00 ZEPHYRHILLS,FL 33542 Electrical Valuation:$38,125.60 Phone: (813)479-3516 Mechanical Valuation: PlumbingValuation: Total Valuation:$38,125.60 l/ Total Fees:$345.95 Amount Paid:$345.95 Date Paid:3/17/2021 2:31:39PM Project Description INSTALLATION ROOF MOUNT SOLAR SYSTEM Application Fees Electrical Plan Review Fee $115.32 Electrical Permit Fee $230.63 REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each subsequent reinspection. Notice: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permit required from other governmental ` entities such as water management, state agencies or federal agencies. "Warning to owner:Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications add fee Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. ONT CTOR SIGNATURE PE IT OFFICE PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 -3-.1- Building Department Date Received ✓ Phone Contact for Permitting aaaaaa.a aaaaa Owners Name ERIC ALVAREZ Owner Phone Number (813)389-1005 Owner's Address 394358THAVE ZEPHYRHILLS, FL33542 Owner Phone Number Fee Simple Titleholder Name Owner Phone Number Fee Simple Titleholder Address JOB ADDRESS 39435 8TH AVENUE ZEPHYRHILLS, FL33542 LOT# 58 SUBDIVISION SUNSETESTATES02 PB 16 PG 3-4 LOT 58 PARCEL ID# 12-26-21-0310-00000-0580 (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED B NEW CONSTR B ADD/ALT = SIGN = = DEMOLISH INSTALL REPAIR PROPOSED USE SFR = COMM = OTHER TYPE OF CONSTRUCTION BLOCK FRAME = STEEL DESCRIPTION OF WORK ROOF MOUNTED SOLAR PV SYSTEMINSTALLATION-11.55 KW BUILDING SIZE I SO FOOTAGE HEIGHT BUILDING 1$ VALUATION OF TOTAL CONSTRUCTION ELECTRICAL $$38,125.60 AMP SERVICE = PROGRESS ENERGY = W.R.E.C. =PLUMBING $ =MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION ►Y(/ C =GAS = ROOFING SPECIALTY = OTHER FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES NO BUILDER � COMPANY SIGNATURE — REGISTERED Y/N FEE CURREN Y/N Address License# db1, ' () ELECTRICIAN COMPANY SIGNATURE REGISTERED Y/N FEECURREN YIN Address License# PLUMBER COMPANY SIGNATURE REGISTERED Y/N FEE CURREN Y/N Address License# MECHANICAL COMPANY SIGNATURE REGISTERED Y/N FEE CURREN Y/N Address License# OTHER COMPANY SIGNATURE REGISTERED Y/N FEE CURREN Y/N Address License# Il"1111 l[YIJa[E[! - Sunmodo Nano Mount are secured to rafters - Sunmodo Nano Mount are secured to plywood decking Install will be done t° Manufacturer Spec �iiiiir @ 72" O.C. in Zone 1, @ 72" O.C in Zone 2e, @48" O.C. in Zone 1 , @ 48" O.C in Zone 2e, �``;E c. c/''%, @ 48" O.C. in Zone 2n, @ 48" O.C. in Zone 2r, @ 24" O.C. in Zone 2n, @ 24" O.C. in Zone 2r Godwin Engineering and 4 8" O.C in Zone 3 e & 4 8" O.C. in Zone 3 r 'n Zone 3 r Design, LLC o:@ @ @ 24 O.C in Zone 3e, & @ 24 O.C. i o e 8378 Foxtail Loop 236o * using 5/16" x 4.75" stainless steel Lag bolts. Pensacola, FL 32526 using (4) #6.3mm x 76.2mm stainless steel Lag bolts. D. Chad Godwin, PE ='o'•, sr OF •`�`�= - Subject roof has One layer. - Subject roof has One layer. Chad@godwineng.com ' - All penetrations are sealed. - Allpenetrations are sealed. �°"A;,� 1 r��i� ii Roof Section Pitch Roof Rafter and Spacing Overhang Notes: , R1 -R3 4/12 2"x4" @ 24 O.C. 21 " Truss SOLAR BEAR 6101 Johns Rd, Ste 8 -Designed as per ASCE7-16 Customer Info: Tampa, FL 33634 Inverter Type: Enphase IQ7-60-2-US 727-471-7442 -Modules mounted flush to roof no higher PV Panel: (35) Silfab-SIL-330NL than 6" above surface. Racking: Iron Ridge XR100 Eric Alvarez Date: 2/17/2021 -Per 2020 FBC, the Roof Mounted PV System Total Wattage: 11,550W 39435 8th Ave Drawn by: ZU will be subject to the following design criteria: Roof Type: Composition Shingles Revised b : Wind Load: 7 to 20 Deg Zephyrhills, FL Rev #: 00 Date: Wind Speed(Vult) - 137mph 3 sec gust, Fastener Type: Use Sunmodo Nano Mounts 33542 Rev Datteo: Exposure Category - B Page: S-2 SOLAR PV SYSTEM EQUIPPED 318 IN MIN.TEXT WITH RAPID SHUTDOWN i I;. _ WARNING. 11 DUAL POWER SUPPLY INVERTER OUTPUT CONNECTION: Enphase Output Ckt Per String TURN RAPID SHUTDOWN S SOURCES:UTILITY GRID AND WITCH T PV SOLAR ELECTRIC SYSTEM DO NOT RELOCATE THIS 3/16 IN MIN.TE THE"OFF"POSITION T ,vP.�, OVERCURRENT DEVICE To Overcurrent Protection Device SHUT DOWN PV SYSTEM AND REDUCE Photovoltaics: AC Max Output Current 16 SHOCK HAZARD IN THE AC Max Output Current * 1.25% 20.0 ARRAY. Enphase (35) SilfbSIL330NL IQ Trunk Cable a - - Q-12-240 p POWER SOURCE OUTPUT CONNECTION: Overcurrent Protection(A) 20 DO NOT RELOCATE THIS OVERCURRENT #12AWG THHN-THWN-2 No. of Current Carrying Cond <4 DEVICE IUL 9703 Inverters: Conductor Gauge(AWG) 10 (35) Enphase IQ7-60-2-US Micro Inverters Enphase Total Output Ckt rto rounding Conductor Circuits: AC Max Output Current 35 be bare#8 Awg (1) circuit of(16)Modules AC Max Output Current * 1.25% 43.8 (1) circuit of(7) Modules Overcurrent Protection(A) 50 NEMA 3R (1) circuit of(12) Modules No. of Current Carrying Cond <4 Junction Box Roof Maximum Inverters Per 20A Circuit (16) Conductor Gauge(AWG) 6 #12 AWG THWN for Home runs under 100' Black Ll 1110 AWG THWN for Home runs over 100' Red-L2 NEC LABEL NOTES: (1)Line I -Green-Ground 1. THE WARNING SIGN(S)OR LABEL(S)SHALL COMPLY (l)Line 2 WITH NEC 110.21(B) Per Circuit 2. LABELS SHALL BE SUITABLE FOR THE ENVIRONMENT #8 AWG THWN WHERE THEY ARE INSTALLED. (l)EGC N. 3. LABELS TO BE A MIN LETTER HEIGHT OF 3/8"AND Inside @ least 3/4"Conduit(tbd on site) Meter PERMANENTLY AFFIXED. 4. LABELS SHALL ALSO COMPLY WITH THE SPECIFIC LQ REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION. Main Distribution Panel 150A Main Line Side Tap ARNiNG PHC]TQVOLTA • sa l= RATED AC OUTPUT CURRENT: 35A NOMINAL OPERATING VOLTAGE: 240VAC Manual Lockable Disconnect 60A Service Rated Fused Disconnect `\\`�,l l l l tf���/� Enphase Combiner Box Neutral Dis Ground Bond Godwin Engineering and 1 20A Breaker — — 50A Fuse (1)-Per Circuit Design, LLC p; F ,may 3 Circuits 8378 Foxtail Loop o Disconnect Located Adjacent to Utility Meter Pensacola, FL 32526 =. Solar Combiner Box #6 AWG THWN #6 AWG THWN D. Chad Godwin PE i� + SATE OF #X-IQ-AMI-240 (1)Line I (1)Line I . A (1)Line2 @gg. // - R►DP-�'���\\ (I)Line2 (#8(1)EGC (1)Neutral Chad odwinencom ,/ass/O AL in @ least 3/4"Conduit Typically in cy least 3/4"Conduit Typically In Compliance 2ith NEC 705(D)L.) (l)#8 AWG EGC&GEC Refer to NEC 312.8 for SOLAR BEAR Conditions on taps in switch ,,,+o.,+. . o..uu.••nror..:n. and over current devices Enclosures. 6101 Johns Rd, Ste 8 If the conditions are not met a tap box will System meets the grounding requirements of NEC 690.43 need to be installed. Tampa, FL 33634 Including the label below Note: GEC NOTES Customer Info: 727-471-7442 Provide a grounding electrode system for an -All wiring to meet the 2017 NEC and In Case of Emer enc Call Eric Alvarez ungrounded system per 690.47(C)(3). Date: 2/17/2021 g y Florida electric codes. - GEC must be installed per 250.64 Inverter Type: Drawn by: ZU Enphase IQ7-60-2-US Solar Bear - GEC must be continuous un-spliced or irreversibly spliced from En p Q 60A Disconnect inverter to existing service ground system or continuous from the 39435 8th Ave PV Panel: at 727-471-7442 arrays to the existing service ground system. ReV1Sed b (35) -Type of conduit to be determined - If GEC is not continuous from the array to the existing service ground Zephyrhills, FL Rev #: 00 Silfab-SIL-330NL EC #: EC 13006630 on site by contractor. an additional ground system must be provided from the arrays to a Total Wattage: grounding electrode per 690.47(D) 33542 Rev Date: - GEC must be min#8 AWG and installed in conduit 11,550W Install will be done to Manufacturer Spec - If GEC is not in conduit,it must be#6 min per NEC 690.54 Page: E-1 37'-9" 50'-7" 37'-9 ' Hot Water Heater 15'-7" O IA ° L AAE4 23'-9" 28'-3" 23'-9" R-1 R-2 R-3 # Modules (6) # Modules (17) # Modules (12) Pitch: 18° Pitch: 18° Pitch: 18° Azimuth: 270° Azimuth: 180° Azimuth: 90° 3'-3" Max cantilever is 24" as per manufacturer spec. Zone 1: * 1 * " Plans satisfy zones FBC-1510.7.1 Max Cantilever = Max Span (3)=72 (3)=24 Install will be done to Manufacturer Spec Max cantilever is 24" as per manufacturer spec. Zone 2e: 1 1 Max Cantilever = Max Span * (3)=72��*(3)=24 Godwin Engineering and O:, F •,� Max cantilever is 16" as per manufacturer spec. Design, LLC Zone 2n:Max Cantilever = Max Span (3)=48 *(3)=16 8378 Foxtail Loop Iron Ridge Rail * 1 _ ►� 1 _ �� XR-100 17' 2 Pensacola, FL 32526 r OF Max cantilever is 16" asspec.per manufacturer o • Zone 2r: D. Chad Godwin, PE i �`�. L RtioP 15 Max Cantilever = Max Span * (3)=48"*(3)=16" Chad@godwineng.com Max cantilever is 16" as per manufacturer spec. ���►�� 11� ��y���� Zone 3e: * I _ „* 1 _ „ Max Cantilever = Max Span (3)=48 (3)=16 Max cantilever is 16" as per manufacturer spec. - Splice Bar 10 Zone 3r: * I „* 1 SOLAR BEAR Max Cantilever = Max Span (3)=48 (3)=16 Sunmodo Nano Mounts 51 ........... ............,,,.,.. Iron Ridge UFO's 80 6101 Johns Rd, Ste 8 Iron Ridge Sleeves/End Caps 20 Customer Info: Tampa, FL 33634 Flashed Combiner 3 Inverter Type: Enphase IQ7-60-2-US 727-471-7442 Iron Ridge Ground Lugs 5 PV Panel: (35) Silfab-SIL-330NL Silfab-SIL-330NL 35 Eric Alvarez Date: 2/17/2021 Enphase IQ7-60-2-US 35 Racking: Iron Ridge XR100 60A Fused Disconnect 1 Total Wattage: 11,550W 39435 8th Ave Drawn by: ZU 50A Fuses 2 Roof Type: Composition Shingles Zephyrhills, FL Revised by: 20A Breakers 3 Wind Load: 7 to 20 Deg Rev #: 00 Enphase Combiner Box 1 33542 Fastener Type: Use Sunmodo Nano Mounts Rev Date: Page: S-l A .....:• ..... . • Test Conditions STC NOCT ;;;t;•t�� Module Power(Pmax) WI:, 330 235 • - Maximum power voltage(V max) V 33.3 30.2 Maximum power current(I max) A 9.92 _ Open circuit voltage(Voc) _ V 40.5 36.7 - E5 ' Short circuit current(Isc) A 10.42 8.2 1 1 Module efficiency % _ 19.4 _ SOLAR Maximum system voltage(VDC) _ _ V� 1000 Max series fuse rating A 20 Power Tolerance W 0 to+10 Measurement conditions:STC 1000 W/m2•AM 1.5•Temperature 25°C•NOCT 800 W/mz•AM 1.5•Measurement uncertainty 5 3% •Sun simulator calibration reference modules from Fraunhofer Institute.Electrical characteristics may vary by±5%and power by 0 to+10W. AUT0r1kTFD °nlv�L Temperature Coefficient Isc 0.064%/°C _ Temperature Coefficient Voc _ _• -0.28%/°C Temperature Coefficient Pmax -0.36%/°C NOCT(±2°C) 46°C ooerating temperature -40/+85°C INDUSTRY LEADING WARRANTY .. ' All our products include an industry ■ a leading 25-year product workmanship Module weight _ 18.6 kg±0.2 kg 41 ±0.4 lbs and 30-year performance warranty. Dimensions(H x L x D) 1700 mm x 1000 mm x 38 mm 66.9 in x 39.4 in x 1.5 in Maximum surface load(wind/snow)* 4000 Pa rear load/5400 Pa front load N/m2 83,51112.81b/ftA2 35+ YEARS OF SOLAR INNOVATION Hail impact resistance o 25 mm at 83 km/h ol in at 51.6 mph 60-Si mono PERC-5 busbar 66-5 mono PERC-5 busbar Leveraging over 35+years of worldwide Cells 158.75 x 158.75 mm 6.25-x 6.25 Inch experience in the solar industry,Silfab Glass 3.2 mm high transmittance,tempered,DSMI0.126 in high transmittance,tempered,DSM is dedicated to superior manufacturing anthr fl�cty coat!ng aiiti retlectiv2 Qtating Cables and connectors(refer to installation manual) 1200 mm,05.7 mm,MC4 from Staubli 47.2 in,00.22 in(12AWG),MC4 from Staubli processes and innovations such as High durability,superior hydrolysis and UV resistance,multi-layer dielectric film, Bifacial and Back Contact technologies, Backsheet fluorine-free PV backsheet to ensure our partners have the latest in Frame _ _ Anodized Aluminum(Black) _ solar innovation. Bypass diodes 3 diodes-30SQ045T(45V max DC blockingvoltage,30A max forward rectified current) - unction Box UL 3730 Certified,IEC 62790 Certified,IP67 rated NORTH AMERICAN QUALITY Silfab is the leading automated solar Module product workmanship warranty 25 years** - _ _ module manufacturer in North America. power performance guarantee th 30 years m o Linear ≥97,1%end 1 year ≥91.6%end.12 year ≥85.1%end 25 year ≥82.6%end 30 year IN Utilizing premium quality materials and _ J.fi '.l_.nss,ssxI In strict quality control management to deliver ULC ORD C1703,UL1 703,CEC listed***,UL 61215-11-1-11-2,UL 61730-11-2,IEC 61215-1/- the highest efficiency,premium quality Product 1-1/-2***.IEC 61730-1/-2***,CSA C22.2#61730-1/-2***,IEC 62716 Ammonia Corrosion; PV modules. IEC61701:2011 Salt Mist Corrosion Certifed,UL Fire Rating:Type 2 Factory ISO9001:2015 _ iii Modules Per Pallet:26 Effvs.Irr Performance SL-330 NL Pallets Per Truck:36 ••••••«••••••••••.. 10°c iii Modules Per Truck:936 20 ' I`l *A Warning.Read the Safety and Installation Manual 19 25°C '" for mounting specifications and before handling 4o^c installing and operating modules. 18 • **12 year extendable to 25 years subject to regis- 17 55°c • • . • tration and conditions outlined under"Warranty'at 70°C www.silfabsolar.com. 16 , e • • - -■. • • 11 • _ ***Certification and CEC listing in progress.August S 1 s 1 2020 expected completion date for CEC listing,IEC m • -• .. •. - -.. • ■ •' •. . ■ 61730/61215 and CSA C22.2#61730-1/-2 14 ' g ! : 1hiF • . . Third-party generated pan files from Fraunhofer-IuI • - r • Institute for Solar Energy Systems ISE are available E 1 r ! for download at:www I 1 I L[,.1 .silfabsolar.com/downloads 120 200 400 600 a00 1000 I t • • • _ c • • r ' • Irradiance(W/m') c . e'L .�,ar i2eanl • ■. • • •111` • r • • r • r� a�t+a. a . . .. .. . EE• gDrarwtbSilfab Solar I nc. `!__ _____ii 33.,, ml •240 Courtneypark Drive East L 33ri10s0 ml - J• , •. • nada Z :1• S % Tel+1 905-255-2501 1 Fax+1 905-696-0267• info@silfabsolar.com I www.silfabsolar.com z ri © ® Silfab Solar Inc. x2020 TOP PERFORMER d 800 Cornwall Ave I ev i I Bellingham WA 98225 USA py MODULE NNGL Tel+1 360-569-4733 RELIABILITY SCORECARD Data Sheet Enphase IQ 7 and IQ 7+ Microinverters Enphase Microinverters Region:AMERICAS INPUT DATA(DC) IQ7-60-2-US/IQ7-60-B-US IQ7PLUS-72-2-US/IQ7PLUS-72-B-US Commonly used module pairings' 235W-350W+ 235 W-440W+ Module compatibility 60-cell PV modules only 60-cell and 72-cell PV modules Maximum input DC voltage r,i,`. Peak power tracking voltage 27 V-37 V 27 V-45 V Operating range +6 V•48V 16 V-60 V Min/Max start voltage 22 V/48 V 22 V/GO V Max DC short circuit current(module Ise) 15A 15A The high-powered smart grid-ready Overvoltage class DC port II II Enphase Enphase IQ 7 MicroTM and Enphase IQ 7+ Micro" DC port backfeed current 0 A n Q 7 and I Q 7+ dramatically simplify li the installation p rocess while PV array configuration 1 x 1 ungrounded array;No additional OC side protection required; AC side protection requires max 20A per branch circuit achieving the highest system efficiency. OUTPUT DATA(AC) IQ 7 Microinverter IQ7+Microinverter Microinverters Part of the Enphase IQ System,the IQ 7 and Peak output power 250 VA 295 VA Maximum continuous output power 240 VA 290 VA IQ 7+ Microinverters integrate with the Enphase Nominal(L:L)voltage/range 24t1 Vi 1 208 v/ 240 V/ 208V/ 211-264 V 183-229 V 211-264 V 183-229V IQ Envoy , Enphase IQ Battery1M, and the Enphase Maximum continuous output current 1.0 A(240 V) 1.15 A(208 V) 1.21A(240V) 1.39 A(208 V) EnlightenTM monitoring and analysis software. Nominal freq�iency 60 Hz 60 Hz Extended frequency range 47-68 Hz 41-68 Hz IQ Series Microinverters extend the reliability AC short circuit fault current over 3 cycles 5.8 Arms 5.8 Arms standards set forth by previous generations and Maximum units per 20 A(L-L)branch circuit' 16(240 VAC) 13(208 VAC) 13(240 VAC) 11 (208 VAC) Overvoltage class AC port III undergo over a million hours of power-on testing, 0 AC port backfeed current 0 A 0 A enabling Enphase to provide an industry-leading Power factor setting 1 t! 1.0 warranty of up to 25 years. Power factor(adjustable) 0.7 leading...0.7'lagging 0.7 leading...07lagging EFFICIENCY @240 V @208 V @240 V @208 V fi Peak CEC efcienev c . 9t- GEC weighted efficiency 97.0% 97.0% 97,0% 97.0% MECHANICAL DATA Ambient temperature range -40°C tc'+65°C Relative humidity range 496 to 100%(condensing) Easy to Install Connector type(IQ7-60.2-US&IQ7PLUS-72-2-US) MC4(or Amphenol H4 UT?with additional Q-DCC-5 adapter) Connector type(IQ7-60-B-US&IQ7PLUS72-8-US) Friends PV2(MC4 intermateable), Lightweight and simple Adaptors for modules with MC4 or UTX connectors: • -PV2 to MC4;order ECA-S20-S22 Faster installation with improved,lighter two-wire cabling PV2 to UTX,order ECA-S20-S25 • Built-in rapid shutdown compliant(NEC 2014&2017) Dimensions(WxHxOl 212 mm x 175 mm x 30.2 mm(without bracket) Weight 1.08 kg(2.38 Ibs) Productive and Reliable coofirtt, Natural convection-No far-.. Approved for wet locations Yes • Optimized for high powered 60-cell and 72-cell*modules Pollution degree PD3 • More than a million hours of testing Enclosure Class It double-insulated,corrosion resistant polymeric enclosure • Class II double-insulated enclosure Environmental category UV exposure rating NEMA Type 6/outdoor • UL listed FEATURES Gomm Power Line t,ommunicatlon(PLC j �� Monitoring Enlighten Manager and MyEnlighten monitoring options. j Smart Grid Ready Both options require installation of an Enphase IQ Envoy, :. Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load-break �lA�f Complies with advanced grid support,voltage and disconnect required by NEC r,90. r c..r ' ; • frequency ride-through requirements Compliance CA Rule 21 (UL 1741-SA) • Remotely updates to respond to changing UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B. ICES-0003 Class B, grid requirements CAN/CSA-C22.2 NO.107.1-01 This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and • Configurable for varying grid profiles NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems,for AC • Meets CA Rule 21 (UL 1741-SA) and DC conductors,when installed according manufacturer's instructions. *The IQ 7+Micro is required to support 72-cell modules. 1.No enforced DC/AC ratio.Seethe compatibility calculator at https://enphase.com/en-us/supPort/module-camPatibilitY. com/en-uslsiipport/module-com atibility, 2.Nominal voltage range can be extended beyond nominal if required by the utility. 3.Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. EN PHASE. To learn more about Enphase offerings,visit enphase.com EN PHASE. To learn more about Enphase offerings,visit enphase.com V ©2018 Enphase Energy.All rights reserved.All trademarks or brands used are the property of Enphase Energy,Inc. 2018-05-24 IRONRIDGE XR Rail Family XR Rail Family The XR Rail Family offers the strength of a curved rail in three targeted sizes. Each size supports specific design loads, while minimizing material costs. Depending on your location, there is an XR Rail to match. Solar IS Not Always Sunny Over their lifetime, solar panels experience countless extreme weather events. Not just the worst storms in years, ------ A but the worst storms in 40 years. High winds capable of ripping panels from a roof, and snowfalls weighing ' f- VV enough to buckle!a panel frame. XR Rails are the structural backbone preventing XR10 XR100 XR1000 these results. They resist uplift, protect against buckling and safely and efficiently XR1 0 is a sleek,low-profile mounting XR1 00 is the ultimate residential XR1 000 is a heavyweight among transfer loads into the building structure. rail,designed for regions with light or mounting rail.It supports a range of solar mounting rails.It's built to handle Their superior capability no snow.It achieves 6 foot spans,while wind and snow conditions,while also extreme climates and spans up to 12 Thee requires fewer roof spanning capability remaining light and economical. maximizing spans up to 8 feet. feet for commercial applications. attareducing the number of roof 6'spanning capability • 8'spanning capability • 12'spanning capability penetrations and the amount Moderate load capability • Heavy load capability • Extreme load capability Clear&black anodized finish Clear&black anodized finish • Clear anodized finish of installation time. Internal splices available Internal splices available Internal splices available Rail Selection The following table was prepared in compliance with applicable engineering codes and standards. Values are based on the following criteria:ASCE 7-10, Roof Zone 1, Exposure B, Roof Slope of 7 to 27 degrees and Mean Building Height of 30 ft. Visit lronRidge.com for detailed span tables and certifications. ■ 3 t Force-Stabilizing Curve 100 Sloped roofs generate both vertical and lateral 120 forces on mounting rails which can cause them None to bend and twist.The curved shape of XR Rails 140 XR10 XR100 XR1000 spa cally_designed to increase strength in both directions while resisting the twisting.This unique 160 feature ensures greater security during extreme weather and a longer system lifetime. 100 I 120 10-20 140 160 100 30 160 Compatible with Flat&Pitched Roofs Corrosion-Resistant Materials - XR Rails are IronRidge otters All XR Rails are made of 6000-series 40 compatible with a range of tilt leg r aluminum alloy,then protected with an 1.60 FlashFoot and options for flat anodized finish.Anodizing prevents surface other pitched roof roof mounting and structural corrosion,while also providing 50-70 160 attachments. applications. a more attractive appearance + 80-90 160