HomeMy WebLinkAbout21-1637 ;-o
o,
City & ZephyrhiIIS PERMIT NUMBER
5335 Eighth Street
Zephyrhills, FL 33542 BNR-001637-2021
:- Phone: (813)780-0020
Fax: (813)780-0021 Issue Date: 03/29I2021
Permit Type: Building New (Residential)
'Property,Number Street Address
24 26 210110 00000 2410 39800 Harvest Creek Lane
Owner Information. Permit Information Contractor Information
Name: LENNAR HOMES LLC Permit Type:Building New(Residential) Contractor: LENNAR HOMES LLC
Class of Work:SFR Construct
Address: 4600 W Cypress St 200 Building Valuation:$267,205.80
TAMPA,FL 33607 Electrical Valuation:$40,080.87 I
Phone: (813)574-5700 Mechanical Valuation:$18,704.41
Plumbing Valuation:$26,720.58
Total Valuation:$352,711.66
Total Fees:$19,612.30
Amount Paid:$19,612.30
Date Paid:3/29/2021 8:37:51AM
Project Description
CONSTRUCT SINGLE FAMILY 2,372 SQ FT
Application Fees
Transportation Impact Fee-City $36.32 Address Fee $30.00
Building Plan Review Fee $683.02 Mechanical Plan Review Fee $66.76
SIF 1 percent Fee $83.28 3/4 Water Meter Fee(Calc) $473.78
Electrical Permit Fee $240.40 Mechanical Permit Fee $133.52
Electrical Plan Review Fee $120.20 Driveway Fee $45.00
Transportation Impact Fee $3,595.68 Plumbing Plan Review Fee $86.80
School Impact Fee $8,328.00 Sewer Connection Residential Fee $2,090.00
Public Safety Impact Fee-Admin $26.35 Public Safety Impact Fee-Police $254.00
Building Permit Fee $1,366.03 Water Connection Residential Fee $1,010.00
Plumbing Permit Fee $173.60 Park Impact Fee-Single Familylrownhome $769.56
REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c)the
local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or
first reinspection,whichever is greater,for each subsequent reinspection.
Notice: In addition to the requirements of this permit,there may be additional restrictions applicable to this property that
may be found in the public records of this county, and there may be additional permit required from other governmental
entities such as water management, state agencies or federal agencies.
"Warning to owner:Your failure to record a notice of commencement may result in your paying twice for
improvements to your property.If you intend to obtain financing,consult with your lender or an attorney
before recording your notice of commencement."
Complete Plans,Specifications add fee Must Accompany Application.All work shall be performed in
accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O.
NO OCCUPANCY BEFORE C.O.
'
TOR SIGNATURE PE IT OFFICE
PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION
CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED
PROTECT CARD FROM WEATHER
INVOICE1111 '
FOR •
BILLING CONTACT
STEVE SMITH '
LENNAR HOMES LLC .
4600 W CYPRESS ST
TAMPA, FL 33607
INVOICE NUMBER INVOICE DATE INVOICE DUE DATE INVOICE STATUS INVOICE DESCRIPTION
INV-00002917 03/23/2021 03/23/2021 Due NONE
REFERENCE NUMBER FEE NAME TOTAL
BNR-001637-2021 3/4 Water Meter Fee(Calc) $473.78
Address Fee $30.00
Building Permit Fee $1,366.03
Building Plan Review Fee $683.02
Driveway Fee $45.00
Electrical Permit Fee $240.40
Electrical Plan Review Fee $120.20
Mechanical Permit Fee $133.52
Mechanical Plan Review Fee $66.76
Park Impact Fee-Single Family/Townhome $769.56
Plumbing Permit Fee $173.60
Plumbing Plan Review Fee $86.80
Public Safety Impact Fee-Admin $26.35
Public Safety Impact Fee-Police $254.00
School Impact Fee $8,328.00
Sewer Connection Residential Fee $2,090.00
SIF 1 percent Fee $83.28
Transportation Impact Fee $3,595.68
Transportation Impact Fee-City $36.32
Water Connection Residential Fee $1,010.00
39800 Harvest Creek Lane Zephyrhills, FL 33540 SUB TOTAL $19,612.30
REMITTANCE INFORMATION TOTAL $19,612.30
City of Zephyrhills
5335 8th Street
Zephyrhills, FL 33542
March 23,2021 � � :� � 5335 8th Street,Zephyrhills,FL 33542 v Page 1 of 1
PASCO COUNTY Receipt Date: 04/09/2 021
D A S C BUILDING CONSTRUCTION SERVICES Receipt Number: 2034489
8731 Citizens Drive
COUNTY FL06VA Suite 230
0Pr-x Srvim.I/imumr ftr,,cr-s. New Port Richey, FL 34654
72-7-847-8126 1-7
NOT A PER"'Mff
Paid By Check# CC Auth# Cashier ID Workstation
Check 01591466 MLARNOLD BCCCP47L
Fee Description Amount Paid
IMpact Fee Residential Solid Waste Single Family 50.58
Total Payments: $50.58
Pavor Address Phone
LENNAR
Comments:
24-26-21-0110-00000-2410
39800 HARVEST CREEK LANE
While you will be paying your bill with Pasco County Building Construction Services,the full amount of the credit card or e-check fees,NOT shown above,Is collected by First
Billing payment services.
myreportslreportsllproductionIPASCOICustomer Receipt vlfrpt Print Date: 04/0-9/2021 Page 1 of 1
813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021
Building Department
Date Received Phone Contact for Permitting 813 363 2891
,
Owner's Name Lermar Homes,LLC Owner Phone Number r8l 35 7 4.5 7 00
Owner's Address 4600 W.Cypress St.Ste.200,Tampa,FL 33607 Owner Phone Number
Fee Simple Titleholder Name N/A Owner Phone Number
Fee Simple Titleholder Address N/A
JOB ADDRESS 39800 Harvest Creek Lane LOT# 6241
SUBDIVISION Hidden River Phase 2 1 PARCEL ID#1 24-26-21-0110-00000-2410
(OBTAINED FROM PROPERTY TAX NOTICE)
WORK PROPOSED NEW CONSTR 8 ADD/ALT SIGN, DEMOLISH
INSTALL REPAIR
PROPOSED USE SFR F__1 COMM OTHER-,'-I
TYPE OF CONSTRUCTION BLOCK FRAME STEEL
DESCRIPTION OF WORK Single Family Residence Pool Screen Enclosure/Fence
U/R SF 2372 1 Story-,
BUILDING SIZE SCI FOOTAGE HEIGHT
. . . . . . . . . . . .
BUILDING $ $267,205.80 VALUATION OF TOTAL CONSTRUCTION
OELECTRICAL 1$ $40,080.87 1 AMP SERVICE FX_� PROGRESS ENERGY W.R.E.C.
PLUMBING $ $26,720.58
MECHANICAL ' $18,704.41 VALUATION OF MECHANICAL INSTALLATIN
=GAS 0 ROOFING Q "SPECIALTY = OTHER
FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA DYES Do
. . ..6-2 a E a a a . . .. . . . . . . . . . . .
BUILDER COMPANY Len mar Homes,LLC
SIGNATURE REGISTERED Y/ N FEE CURREN LLLN_j
Address 4600 W. ess St.Ste.200,Tampa,FL 33607 License# I CGC1518166
ELECTRICIAN- COMPANY Edmonson Electric, Inc.
SIGNATURE REGISTERED Y1 IN FEE CURREN
Address 11034 Skipper Riad,Tampa, FL 33613 License# [EC13005408.
PLUMBER
COMPANY 1Bayonet Plumbing, Heating &AC, Inc
REGISTERED YIN FEE CURREN SIGNATURE LYIN
Address P.O. Box 5308, Bayon1t, FL 34674-5308 License# I CFC042998
1 MECHANICAL COMPANY Bayonet Plumbing, Heating &AC, Inc
SIGNATURE REGISTERED Y1 N FEE CURREN Y/N
Address P.O. Box 5308, Bayoneti FL V4674-5308 License# CAC058062
OTHER COMPANY I C Sterling Quality Roofing, Inc
SIGNATURE REGISTERED Y/ N FEE CURREN I Y/N
Address 14211 Shoal Line Blvd, Spril 9 Hill, FL 34607-7 License# 1 CCC057991
RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction,
Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans wl Silt Fence installed,
Sanitary Facilities&I dumpster;Site Work Permit for subdivisions/large projects
COMMERCIAL Attach(2)complete sets of Building Plan2s'plus a Life Safety Page;(1)set of Energy Forms.R-O-W.Permit for new construction.
Minimum ten(10)working days after subIrnittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed,
Sanitary Facilities&I clumpster.Sitb'Work Permit for all new projects.All commercial requirements must meet compliance
SIGN PERMIT Attach(2)sets of Engineered Plans.
****PROPERTY SURVEY required for all NEW construction.
. . . . . . . . . . . . . . . .
Directitas:
Fill out application completely.
Owner&Contractor sign back of application,notarized;.;``-,..
If over$2500,a Notice of Commencement Is required. (AIC upgrades over$7500)
Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same
OVER THE COUNTER PERMITTING (copy of contract required)
Reroofs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage)
Driveways-Not over Counter if on public roadways..needs ROW
NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed"restrictions"
which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any
applicable deed restrictions.
UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or
contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the
contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation
under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the
intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847-
8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign
portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the
contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco
County.
TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands
that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of
use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and — -
90-07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of
permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to .. ..
receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or
final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact
fees are due, they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances.
CONSTRUCTION LIEN LAW(Chapter 713, Florida Statutes, as amended): If valuation of work is$2,500.00 or more, I
certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's
Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone
other than the"owner", I certify that I have obtained a copy of the above described document and promise in good faith to
deliver it to the"owner" prior to commencement.
CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work
will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is
hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has
commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating
construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also
certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is
my responsjbility to identify what actipns I must take to be in compliance. Such agencies include but are not limited to:
Department 8f tvironr lbntal Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive
Lands 'Water/1Nastewat" Treatment.
- Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering
Watercourses.
- Army Corps of Engineers-Seawalls, Docks, Navigable Waterways.
- Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment,
Septic Tanks.
- US Environmental Protection Agency-Asbestos abatement.
- Federal Aviation Authority-Runways.
I understand that the following restrictions apply to the use of fill:
- Use of fill is not allowed in Flood Zone W" unless expressly permitted.
- If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a
"compensating volume" will be submitted at time of permitting which is prepared by a professional engineer
licensed by the State of Florida.
- If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall
construction, I certify that fill will be used only to fill the area within the stem wall.
- If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent
properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating
the conditions of the building permit issued under the attached permit application, for lots less than one (1)
acre which are elevated by fill, an engineered drainage plan is required.
If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of,the permitting conditions set forth in
this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work,
plumbing, signs, wells, pools, air conditioning, gas, or qther installations not specifically included in the application. A
permit issued shall be construed to be a license to proceQd with the work and not as authority to violate, cancel, alter, or
set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter
requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid
unless the work authorized by such permit is commenced within six months_of permit issuance, or if work authorized by
the permit is suspended or abandoned for a period of six(6) months after the time the work is commenced. An extension
may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate
justifiable cause for the extension. If work ceases for ninety(90)consecutive days, the job is considered abandoned.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR
PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT
WITH YOUR LENDER OP.AN ATTORNEY BEFORE RECORDING YOUR N I E OF COMMENCEMENT.
FLORIDA JURAT(F.S.
—OWNER OR AGENT CONTRACTOR-
Subscribed --
and sworn to or efore me this Subscribed and sworn to r a d)before me this
e4-rev-L r by Ashlee i za-Feb-zi by Ashlee khan
Who is/are personally known to me or Who is/are personally known to me or
as identification. as identification.
Notary Public Notary Public
Commission No. HH 000460 Commission No. HH 000460
Elissa M.Holleran Elissa M.Holleran
Name of Notary typed,printed or stamped Name of Notary typed,printed or stamped
"'�►,; ELISSAM,HOLLERAN r �► ELISSAM.HOLLERAN
' Commission#HH 000400 . Commission#HH 000460
Expires June 0,2024 �,R. Q o Expires June 0,2024
Am, Bor&d7W Troy Fafnlneurance800.388.7010 „t� BorAWTtwTroyFalnlnsurance600.385-7019
I
y [
E
PASCO COUNTY, FLORIDA
Permit No. 3
Date Permitted 3—.
"Builder Name/Owner Name +' Control#' "
County Parcel No. N26 7,1 b1100(&Q.7_!j(2 SubDiv:
Address/Location 1&9d0
CiassificationIType of Usq 6G' 4 l _ 4vik
TRANSPORTATION IMPACT FEE Rate: Sq.Ft Unit: a 72--
Exempt ❑Yes n No How Determined
Impact Fee Amount $. l Zone No. TAZ:
SCHOOL IMPACT FEE
Account (056) Single-Family Detached House Amount $ � Z-
(057) Mobile Home
(058) Other Residential
23) Collection Fee
Exempt d Yes ❑No Now Determined
I
. PARKS AND RECREATION FEE-
Land Account Land Credit Land Total
Recreation Account Recreation Credit Recreation Total
i —��
Zone TOTAL AMOUNT $ ,7�l�j�,)'F''
} Exempt ❑Yes ❑No How Determined
i LIBRARY-FEE
Land Account Land Credit Land Total
Facility Account Facility Credit Facility Total %
Exempt ❑Yes ❑ No How Determined Total Amount
{
RESOURCE FEE ERU
TOTAL AMOUNT;
Prepared By e — Checked By
NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINAL INSPECTION
PERFORMED UNTIL THE TOTAL AMOUNTS LISTED HAVE
BEEN PAID.AND.
RECEIPTED FOR BY A CENTRAL PERMITTING OFFICE OF PASCO COUNTY
Acknowledgement below does not Imply acceptance of concurrence,but simply receipt of-a copy of this form,placing the building permit owner.on notice of this assessment and the condltions of payment for same.
DATE RECEIVED BY
RECEIPT NO. DATE BY
Single Family Dwelling
Plan Review Comments
1- F:F.E;.shall:be a minimum of 8" above the road elevation and an engineered site plan.
2: .Lots shall be graded to comply with R401-.3:of the F:B.C.,
Compaction test required.if 24"-or more of fill_dirt is brought in at any one place.
4: Tie in survey required-bore concrete.
5-. .Driveways require.a R.O:W. use permit: All 4 sides of driveway thru the sidewalk shall have
expansion material.:
6: All setbacks shall bo-met.
p p .y:
7: All, ro ert markers shall be uncovered,and:marked at time of first inspection. . -
8: All A.D.A. requirerrients shall-be met:.
9-. No electric,.plumbing;mechanical, or framing shall be:covered without an inspection and
approval first:
10: All Garages shall comply with section R302.6 of the F.B.-C. (Fire Sepdration).:
11. Appliances.shall.not be-installed in a location.where subject to mecharucai.damage unless
l
protected by'approved barriers. M303;4 of the FR C
12. Water heaters shall comply with section P607.3 of the F.B.C:
13:Foundation supports for A/C units.shall.be rdised at least 3" above finished grade. M1308.1
14. Return air in all bedrooms. F.B.-C. M1620.4
1.5. smoke.detectors.are to be installed in accordance with R313:1_of.the F.B.C.
16. All glazing requirements are to be in accordance with R308.4 of the F.B.-C.
17..All means.of egress are.to be'in accordance with POI of the F.B.C:.
18: "Green gypsum board" shall* Abe used as a backer in showers or tubs. R702:4-2 F.B.C.
19: Combination-type AFCI,breakers are required at all locations requiring an AFCI type breaker.
.
20. Carbon monoxide alarms will be required in new construction that.uses fossil-burning heating.
or appliances or an attached garage. They shall be installed in accordance with the F.B.C:
2:1..All plumbing,inechanical, and electrical shall be separate from unit to unit: This includes all
underground:plumbing and -electric.
22: All 2016 N.E.C. Codes will be enforced:
23. Tamper-Resistant Receptacles in accordance with 406.11 ofthe 2016 N..E.0
24. In accordance with the Land Development Code, lots.shall.be sodded'before final at leas_t 10
feet around the structure.
25. R403.5.3Hot.water.pipe insulation.
Insulation for hot water pipe with a minimum thermal resistance (R-value) of R-3 shall be applied to the
following: .
Piping�1,inch'(1,9.1 mm) and larger in.nominal diameter. .
Piping,serving more than one dwelling unit.
Piping located outside the conditioned space..
Piping from the:water heater to a distribution manifold:
Piping.located under.a floor slab.-
Buried in piping.
Supply and return piping in recirculation systems other than demand recirculation systems.
25. Blower:door test shall be provided before C.O:
26.A copy of the enemy=cacls shall be ivith permit at all limes
27. Copt/of Fnal insulation reO6it shaff be provided with permit before fnaL
28. No fence,pool or screen enclosure :is issued with:this permit.
F.F.E.-Finished Floor Elevation
F.B.C--Florida Building Code.6 h Edition
R.O.W.-Right of Way.
A.D.A.-Americans with Disabilities Act. N.E.C.-National Electric.Code (2016)
a. �...... �\�' f/'' 1 . --"" " �u ��`'' J;+'�`.,.° ram+' .ir�� ♦ �' �\ � � 'k�� c
tF t 1 '/f~ �� _„tea„ �_• � „r'.v' ,.r �r s;'� �^ \ A.
FF FL244
�h e� ] v. s' ram'*�� r� t ?
73.80
73 A } �r
� �,a�:r. s`'r� ��, �,�' ul- �;•" \ , \ ,� \ \ .fir,
FF EL 243 � "� �, ''
73.60 " f i x
73.10
ol
/242
,a� � - 7{;t \ tip \� .i'r r ! ,s A ter•
�*'*" �` � �•�, -�'-� � .Y� �\ ,�+ } r ,,,�f �y„F f`� � \ 7',
249
`,�_ 1 EL
73.50 \.,r;w.�,-..dL
} �� ` ` _
l _
\ r
V
SKETCH ONLY SEC. 24 . TWP. 26 S, RNG. 2E.
PLOT PLAN NOT A 1 BOUNDARY SURVEY
LOT 241 BEARING BASIS:
HIDDEN RIVER PHASE 2 SOUTHWEST BOUNDARY OF SUBJECT LOT BEING N 34!25'41" W
PASCO COUNTY, FLORIDA. DO NOT SCALE THIS PRINT. DIMENSIONS AND
PRELIMINARY DRAWING: N NOTES TAKE PREFERENCE.
THIS PLAN IS FOR PERMITTING PURPOSES ALL DATA SHOWN HEREON BASED ON THE
ONLY, NOT FOR CONSTRUCTION. VERIFY ENGINEERING PLANS OF KIMLEY—HORN AND
ALL DIMENSIONS BEFORE ANY CONSTRUCTION. M ASSOCIATES, INC., PROVIDED BY LENNAR HOMES.
LEGEND: II
10' PUBLIC UTILITY EASEMENT
-,A�,-v = PROPOSED DRAINAGE FLOW
(00.00) = PROPOSED GRADE
E-00.00 = EXISTING GRADE
V)
NOTES:
LOT GRADING TYPE = A
PROPOSED PAD ELEVATION
FRONT SETBACK = 20'
SIDE SETBACK = 10'
REAR SETBACK = 10'
LP V;��
4)
72-29)
0
0'
Is,
Yl
.9�^ �t, ,.oa s},. �,y
LOT 242
It,
0
00 1,
GF IQ.
3r.kp.
ON LOT AREA CALCULATIONS
LOT FT. 4--
LIVING AREA FT.
ENTRY FT.
-(72.8,9,)GARAGE ---SQ. FT.
COVERED LANAI ---SQ. FT. LOT 240
PATIO FT.
CONC, DRIVE =-522—SQ, FT. LOT 251
A/C & CONC PAD --A-----SO. FT.
PRIVATE SIDEWALK =--a---SQ. FT.
IMPERVIOUS ..0
2955 _—SO. FT.
SOD =--�KILEL--SQ. FT.
OFF LOT AREA CALCULATIONS C-) LOT 252
RIGHT OF WAY FT. rN
DRIVE APRON FT.
PUBLIC SIDEWALK FT.
SOD ---SQ. FT. LOT 253
10 TOTALS
AREA FT.
< DRIVEWAY 64
ca —__SO. FT.
EE SIDEWALK FT.
SOD FT.
-0
PROPOSED:
DESCRIPTION: LOWEST FLOOR ELEVATIONS:
m C, LOT 241, MAP OR PLAT ENTITLED 'HIDDEN RIVER PHASE 2", LIVING AREA: 73.70'
1>
AS RECORDED IN PLAT BOOK 079, PAGES 102 THROUGH GARAGE AREA:
CL
- 110, OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. ELEVATIONS REFERENCED TO
In I CURVE I MONS I ARC I CHORD I BEARING I DELTA NATIONAL GEODETIC VERTICAL
C299 1 275.00- 1 9.09, 9.09. S 56!31'07" W 1 01-53-36" DATUM OF 1929. MEAN SEA
C300 1 275.00- 1 16.95' 1 16.95' N 59-13-51- E I 03'31-52" LEVEL= 00.00 FT.
rn
APPARENT FLOOD HAZARD ZONE: "X" COMMUNITY PANEL NO. 12101C 0458 F EFFECTIVE DATE: 09/26/2014
7T7;le Feet: 6623.11 t LENNAR HOMES
o LEGEND:
(C)= CALCULATED DATA, (D)= DEED DATA, (M)= MEASURED DATA, (P)= PLAT DATA, %= CENTERLINE, A/C= AIR CONDITIONER, B/C= BACK OF CURB, C/S=
CONCRETE SLAB, CH= CHORD, CHB= CHORD BEARING, CLF= CHAIN LINK FENCE, CONC= CONCRETE, COV.= COVERED, E/P= EDGE OF PAVEMENT, ESM'T= EASEMENT,
F/C= FENCE CORNER, FCM= FOUND CONCRETE MONUMENT, FIP= FOUND IRON PIPE, FIR= FOUND IRON ROD, FN&D= FOUND NAIL & DISK, FPP= FOUND PINCHED
PIPE, LFE= LOWEST FLOOR ELEVATION, MAS.= MASONRY, OR= OFFICIAL RECORD BOOK, PB= PLAT BOOK, PCP= PERMANENT CONTROL POINT, PRM= PERMANENT
& REFERENCE MONUMENT, R/W= RIGHT OF WAY, R= RADIUS, SIR=SET 1/2" IRON ROD & CAP No. 4493, SN&D= SET NAIL & DISK No,4493, TBM= TEMPORARY
BENCHMARK, U/P= UTILITY POLE, W/F= WOOD FENCE
o JOHN R.BEACH&ASSOCIATES,INC. Drawn By:
o sms
SURVEYORS AND MAPPERS
t
x Ch By:911 WEST ST. PETERSBURG DRIVE JRBecked
ONE OLDSMAR, FLORIDA 34677
WAY (813) 854-1276 FAX (813) 855-8370 S1"=cale:
30'
NOT VALID WITHOUT ORIGINAL SIGNATURE Date: PLOT PLAN 2/19/2021 ACS
AND SEAL OF A FLORIDA LICENSED
ISURVEYOR AND MAPPER
Revisions: SI ATU DATE
r OHN R. CH
FLORIDA'o R.
. LAND SURVEYOR No. 2984 LB#4493
Vi
C
Vi
INSTR#2021050732 OR BK 10300 PG 139 Page 1 of 1
03/12/2021 03:43 PM Rcpt:2272738 Rec:10.00 DS:0.00 IT:0.00
Nikki AlvarezSowles,Esq.,Pasco County Clerk&Comptroller
Permit No. Parcel ID No 24-26-21-0110-00000-2410
NOTICE OF COMMENCEMENT
state of Florida County of Pasco
THE UNDERSIGNED hereby gives notice that Improvement will be made to certain reel property,and in accordance with Chapter 713,Florida Statutes,
the following Wormation Is provided in this Notice of Commencement:
1. Description of Property:legal HIDDEN RIVER PHASE 2 PB 79 PGS 102-110 LOT 241 „ L6 ,r•
street Address: 39800 Harvest Creek Lane Zephryhills FL 33541 r �
r` a
. 2. General Description of Improvement Single Family Residence/Pool I Screen Enclosure/Fence & ®.
A
3. Owner Information: Lennar Homes,LLC.
Name
�600 W Cypress St.Ste 200 Tampa FL 33607
Address City State
Interest In Property:
Name of Fee simple Titleholder. N/A
Of other than owner) i
Address City State
4. Contractor._ Lennar Homes,LLC
Name
4600 W Cypress St,Ste 200 Tampa FLU 33607
Address City State
Contractor's Telephone No.: 813.574.5700
5. surety: .' NIA
Name W J fz
Address City State tZ`� to O U
Amount of Bond:$ Telephone No.: 1L = cr_
6. Lender. N/A O 0 N 0.
Name N 0 2 Ln W O W
Address City State a W Z J C.) ❑
Lenders Telephone No.: CL•O
ca
7. Persons within the State of Florida designated by the owner upon whom notices or other documents may be served as provided by O LL LL- 0: U
Section 713.13(1)(o)M,Florida statutes: } LLl O O LL W
Lennar Homes,LLC Z F= LL
- d W O
Name
WI-- P
IZ'4600 W Cypress St.Ste 200 Tampa FL_607 CO,) = V U
Address city State t— � J
Telephone Number of Designated Person: 813.574.5700 QA L) m ❑ u-
B. In addition to himself,the owner designates N/A of p tr CL Q ?
rr (r 11 2 Q N
to receive a copy ofthe Uenoes Notice as provided in Section 713.13(1)(b),Florida Statutes. 0 W O O } ❑ Uj
Telephone Number of Person or Entity Designated by Owner. LL O ❑ O >
iretion date o1 Notice of Commencement la one 9. Exp year from the date of recording unless a different date Is specified: O N Z J (n a
LL,WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT W LL Y
ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13, FLORIDA STATUTES, AND CAN Q ❑ Y
RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE t.. = lY Z
RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING,CONSULT (/$ H (- 0 Z m
1MTH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT.
STATE OF FLORIDA
COUNTY OF PINELIAS Tf
SWsAufbvf1OWner ollOwnees Authorized Otficer/Diredor/Partner/Manager
Vice President
Signatory'*Title/Office
The foregoing Instrument was admowledged before me Ws 24 day of February by
Steve Robert Smith es Vice President (type of atd car,trustee,attorney In fad)for
_Lennar Homes,LLC (name� Bafwhom Instrument was executed).
Personally Known 0 OR Produced Identification❑ Notary S
Type of Identification Produced Name(Print) Elissa Holleran
Verification pursuant to Section 92.525.Florida Statutes. Under penalties of penury,I declare that l have read the foregoing and that the fads staled in
It are true to the best of my Imowled a and befief.
13J8811tLI10tLERIIN �~� .
COI�tdRklliNHl10D10g Signature of Natural Person Signing Above r
Et�llrJmuQIQtA
+ SootN11oa11gldrYmstoH0041b•7010
wpdats/bcsrbca fo