Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
21-1676
i I III tin.. City of Zephyrhills PERMIT NUMBER 5335 Eighth Street Zephyrhills, FL 33542 ELCMISC-001676-2021 Phone: (813)780-0020 Fax: (813)780-0021 Issue Date: 04/02/2021 Permit Type: Electric Service Replacement/Misc Property Number Street Address 04 26 21 0070 00100 0330 36041 Stable Wilk Avenue Owner Information Permit Information Contractor Information Name: MICHAEL SHOOK Permit Type:Electric Service Replacement/M Contractor: EFFICIENT HOME Class of Work:Add/Alter Residential SERVICES OF FLORIDA LLC Address: 36041 Stable Wilk Ave Building Valuation:$0.00 ZEPHYRHILLS,FL 33541 Electrical Valuation:$33,000.00 Phone: (330)321-8418 Mechanical Valuation: Plumbing Valuation: C _ Total Valuation:$33,000.00 Total Fees:$307.50 Amount Paid:$307.50 \' Date Paid:4/2/2021 11:30:13AM Project Description INSTALLATION ROOF MOUNT SOLAR SYSTEM Application Fees Electrical Plan Review Fee $102.50 Electrical Permit Fee $205.00 REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each subsequent reinspection. Notice: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permit required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications add fee Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. RACTOR �//IPZ coEXPIRESRIN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER 813-780-0020 City of Zephyrh'ills Permit Application Fax-813-780-0021 Building Department /� Date Received Phone Contact for Permitting '(7 9 — 6 •§laIaa III II aaI■I Owner's Name ],, vU/p—` Owner Phone Number 1 Owner's Address 4V U _ -/ Owner Phone Number Fee Simple Titleholder Name Owner Phone Number Fee Simple Titleholder^A�dd^resss`q�1l� JOB ADDRESS OT# Y ,�,,�aL SUBDIVISION S' ��w�� PARCEL ID# D Ll-Zb- Z�- ��� b �,U �3 (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED e NEW CONSTR e ADD/ALT SIGN = = DEMOLISH INSTALL REPAIR PROPOSED USE SFR = COMM = OTHER TYPE OF CONSTRUCTION = BLOCK = FRAME = STEEL = DESCRIPTION OF WORK e \ 4 roci—n'Na nLaA BUILDING SIZE SQ FOOTAGE HEIGHT -CC><ICC ICTICTIC�-Ci-�C�CL'Z'Ct`Clot€-¢"ICE"E"����>C�'S-6-t`S"SS'IE�CIC'�-ICC>e-tZ�C��'ICL'i"'CS-C�S�CICI-'�S� UILDING $ VALUATION OF TOTAL CONSTRUCTION =ELECTRICAL $ AMP SERVICE = PROGRESS ENERGY Q W.R.E.C. =PLUM6ING $ =MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION �J � IIIJJJ =GAS = ROOFING 0 SPECIALTY = OTHER FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES NO. BUILDER COMPANY SIGNATURE REGISTERED I Y/N FEE CURREN Y/N Address License# ELECTRICIAN COMPANY tjW(J` , OrAl r,101J u-S � �_C' SIGNATURE REGISTERED I Y/N FEE CURREN Y/N Address `Q Q License# Z:Ie 3—s:C 1y .PLUMBER COMPANY SIGNATURE REGISTERED Y/N FEE CURREN Y/N Address License# MECHANICAL COMPANY SIGNATURE REGISTERED Y/N FEE CURREN Y/N Address License# OTHER COMPANY SIGNATURE REGISTERED Y/N FEE CURREN Address License# till-Lltall![ata.I Islas[11.111111lllllitialll.l71[II% 6i[I7liltt§21.II1.221 RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date.Required onsite,Construction Plans,Stormwater Plans w/Silt Fence Installed, Sanitary Facilities&1 dumpster;Site Work Permit for subdivisions/large projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction. Minimum ten(10)working days after submittal date.Required onsite,Construction Plans,Stornwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. ****PROPERTY SURVEY required for all NEW construction. Directions; Fill out application completely. Owner&Contractor sign back of application,notarized If over$2500,a Notice of Commencement is required.(AIC upgrades over$7500) •• Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage) Driveways-Not over Counter if on public roadways..needs ROW 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department NOTICE OF DEED RESTRICTIONS:The undersigned understands that this permit may be subject to"deed"restrictions"which may be more restrictive than County regulations.The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES:If the owner has hired a contractor or contractors to undertake work,they may be required to be licensed in accordance with state and local regulations.If the contractor is not licensed as required by law,both the owner and contractor may be cited for a misdemeanor violation under state law.If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work,they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847-8009. Furthermore,if the owner has hired a contractor or contractors,he is advised to have the contractor(s)sign portions of the"contractor Block"of this application for which they will be responsible.If you,as the owner sign as the contractor,that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACTIUTILITIES IMPACT AND RESOURCE RECOVERY FEES:The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings,change of use in existing buildings,or expansion of existing buildings,as specified in Pasco County Ordinance number 89-07 and 90-07,as amended.The undersigned also understands,that such fees,as may be due,will be identified at the time of permitting.It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a"certificate of occupancy"or final power release.If the project does not involve a certificate of occupancy or final power release,the fees must be paid prior to permit issuance.Furthermore,if Pasco County Water/Sewer Impact fees are due,they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713,Florida Statutes,as amended):If valuation of work is$2,500.00 or more,I certify that 1,the applicant, have been provided with a copy of the"Florida Construction Lien Law—Homeowner's Protection Guide"prepared by the Florida Department of Agriculture and Consumer Affairs.If the applicant is someone other than the"owner",I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner"prior to commencement. CONTRACTOR'SIOWNER'S AFFIDAVIT:I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction,zoning and land development.Application is hereby made to obtain a permit to do work and installation as indicated.I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction,County and City codes,zoning regulations,and land development regulations in the jurisdiction.I also certify that I understand that the regulations of other government agencies may apply to the intended work,and that it is my responsibility to identify what actions I must take to be in compliance.Such agencies include but are not limited to: Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands,Water/Wastewater Treatment. Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. Army Corps of Engineers-Seawalls,Docks,Navigable Waterways. Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. US Environmental Protection Agency-Asbestos abatement. Federal Aviation Authority-Runways. I understand that the following restrictions apply to the use of fill: Use of fill is not allowed in Flood Zone"W unless expressly permitted. If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume"will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction,I certify that fill will be used only to fill the area within the stemwall. If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties,the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill,an engineered drainage plan is required. If I am the AGENT FOR THE OWNER,I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction.I understand that a separate permit may be required for electrical work,plumbing,signs,wells,pools,air conditioning,gas,or other installations not specifically included in the application.A permit issued shall be construed to be a license to proceed with the work and not as authority to violate,cancel,alter,or set aside any provisions of the technical codes,nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans,construction or violations of any codes.Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance,or if work authorized by the permit is suspended or abandoned for a period of six(6)months after the time the work is commenced.An extension may be requested,in writing,from the Building Official for a period not to exceed ninety(90)days and will demonstrate justifiable cause for the extension.If work ceases for ninety(90)consecutive days,the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY:IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER QR AN ATTORN-Y BEFORE REC `�R NOTICE OF COMMENCEMENT- FLORIDA JURAT(F.S.117.03) OWNER OR AGENT CONTRACTOR 3�ibe and ssuuyyorn to((or affirmepd)before me this s ri ed an sworn (or ffumed)b�Jo_re,me this by MI('In \InC Ok b in10 t C�fi�S Wit i are PPersonally known to me or has/have produced Who is/ar erson a or has/have produced Y d.�'9,C as identification. ( as identification. Notary Public Notary Public Commission No. 717 )�)Il Commission rNo. V G 3 O Name of Notary typed,Printed of stamped Name of Notary typed,printed or stamped r d�•., LAWREN PHILLIPS Li•,4WRf§Pftblg Notary Public-State of Florida �ypy4i�, e�Fl Commission GG 91351017*. ®�A: My Comm.Expires Sep 16,2023 �� rb,F623 Banded through National Notary Assn. P1r IC16N a'li 10� fy.e4sSt1. DIRECTORY OF PAGES SCOPE OF WORK P-1 54765 PV-1 PROJECT SUMMARY THIS PROJECT INVOLVES THE INSTALLATION OF A GRID- PV-2 SITE PLAN INTERACTIVE PV SYSTEM.PV MODULES WILL BE MOUNTED USING A PREENGINEERED MOUNTING SYSTEM.THE MODULES PV-3 SINGLE-LINE DIAGRAM WILL BE ELECTRICALLY CONNECTED WITH DC TO AC POWER INVERTERS AND INTERCONNECTED TO THE LOCAL UTILITY PV-4 SAFETY LABELS USING MEANS AND METHODS CONSISTENT WITH THE RULES ENFORCED BY THE LOCAL UTILITY AND PERMITTING PV-5.1 ATTACHMENT PLAN 5.1 JURISDICTION. PV-5.2 ATTACHMENT PLAN 5.2 PV-5.3 ATTACHMENT PLAN 5.3 THIS DOCUMENT HAS BEEN PREPARED FOR THE PURPOSE OF DESCRIBING THE DESIGN OF A PROPOSED PV SYSTEM WITH LU PV-6 ATTACHMENT DETAILS ENOUGH DETAIL TO DEMONSTRATE COMPLIANCE WITH PV-7 FIRE SAFETY PLAN APPLICABLE CODES AND REGULATIONS.THE DOCUMENT R,t SHALL NOT BE RELIED UPON AS A SUBSTITUTE FOR > > MODULE DATASHEET m 1e �� FOLLOWING MANUFACTURER INSTALLATION INSTRUCTIONS. Cl) Q LC) THE SYSTEM SHALL COMPLY WITH ALL MANUFACTURERS C) o• X INVERTER DATASHEET y Stab Witk LISTING AND INSTALLATION INSTRUCTIONS,AS WELL ALL Y CY) n APPLICABLE CODES.NOTHING IN THIS DOCUMENT SHALL BE w J J MOUNTING SYSTEM DATASHEETa- INTERPRETED INAWAYTHAT OVERRIDES THEM. MOUNTING SYSTEM ENGINEERING LETTER � SjaIDNO pye CONTRACTOR IS RESPONSIBLE FOR VERIFICATION OF ALL O a. ts• CONDITIONS,DIMENSIONS,AND DETAILS IN THIS DOCUMENT. cL cL LJJ (ii J J UL 2703 GROUND AND BONDING CERTIFICATION ANCHOR DATASHEET .•. SYSTEM DETAILS Q = DESCRIPTION NEW GRID-INTERACTIVE PV SYSTEM O w PROJECT DETAILS 1 PLOT WITH NO ENERGY STORAGE w >_ PROPERTY ADDRESS 0 36041 STABLE WILK AVE, PV-1 SCALE: NTS DC RATING OF SYSTEM 10.23KW � ZEPHYRHILLS,FL 33541 US - AC RATING OF SYSTEM 7.44KW W W ZONING RESIDENTIAL M N AC OUTPUT CURRENT 31.0A USE AND OCCUPANCY ONE-OR TWO-FAMILY DWELLING CLASSIFICATION GROUP(GROUP R3) INVERTER(S) 31 X ENPHASE IQ7-60-2-US UTILITY COMPANY DUKE ENERGY FLORIDA MODULE APTOS SOLAR DNA 120 330 ELECTRICAL CODE 2017 NEC(NFPA 70) (1)BRANCH OF 16 IQ7-60-2-US MICROINVERTERS ARRAY WIRING FIRE CODE 2018 NFPA 1BRANCH UEL RL 1 RA BNCH OF 15 IQ7-60-2-US 2 US ?°'•• ••I HrR S MICROINVERTERS , N.88991 OTHER BUILDING 2020 FL BUILDING CODE CODES INTERCONNECTION DETAILS STATE OF :¢ CONTRACTOR INFORMATION NEW LOAD-SIDE AC CONNECTION S10NAL ENG POINT OF CONNECTION CONTRACTOR RR Thisiitem has PER NEC 705.12(B)(2)(3)(B)AT MSP easolIy signed n: yes Ruiz been digitally SIGNATURE UTILITY SERVICE 120/240V 1( signed and sealed by Reyes Ruiz ' Donate.Printed copies of this document Fii11S MAIN SERVICE PANEL W/200A are not considered signed and sealed -Kytiive Lary, -Hills 9 i�reser.' LOCATION BUSBAR 200A MCB and the sgnature must be verified on C1 any electronic copies. Zephyfhilis Date:2021.03.0312:39:44-0500' South SITE DETAILS ASHRAE EXTREME LOW 1°C(34°F) PROJECT 3J hap* '''gP ASHRAE 2%HIGH 34-C(93°F) SUMMARY LOCALE CLIMATE DATA SOURCE ST.PETERSBURG CLEAR(KSPG) DOC ID:154765-190719-1 WIND SPEED 140 MPH(ASCE7-10) DATE:3/3/21 PV-1 SCALE:NTS CREATOR: RISK CATEGORY II REVIEWER: WIND EXPOSURE CATEGORY B REVISIONS I REYES M RUIZ DONATE PE#88991 AN ENGINEER LICENSED PURSUANT TO CHAP TER 491, CERTIFY THAT THE PV ELECTRICAL SYSTEM AND ELECTRICAL COMPONENTS ARE DESIGNED AND APPROVED USING THE STANDARDS CONTAINED IN THE MOST RECENT VERSION OP THE FLORIDA BUILDING CODE. PV_ 1 GENERAL NOTES P-1 54765 OEQUIPMENT LIKELY TO BE WORKED UPON WHILE 1 ENERGIZED SHALL BE INSTALLED IN LOCATIONS THAT SATISFY MINIMUM WORKING CLEARANCES PER NEC 110.26. ^ CONTRACTOR SHALL USE ONLY COMPONENTS LISTED L BY A NATIONALLY RECOGNIZED TESTING LABORATORY FOR THE INTENDED USE CONTRACTOR IS RESPONSIBLE FOR FURNISHING ALL EQUIPMENT,CABLES,ADDITIONAL CONDUITS, RACEWAYS,AND OTHER ACCESSORIES NECESSARY W 2 FORA COMPLETE AND OPERATIONAL PV SYSTEM. C!� > HOTOVOLTAIC CI) LO 1O ARRAY.5:112(D°)S OPEOD ROOF,12 PV MODULES CM 3 (BLACK FRAME,BLACK BACKSHEET),78°AZIMUTH W -J (N)PROPOSED ROOF-MOUNTED PHOTOVOLTAIC 4 2O ARRAY.5:12(23°)SLOPED ROOF,12 PV MODULES 0 LL_ (BLACK FRAME,BLACK BACKSHEET),257°AZIMUTH W J 5 (N)PROPOSED ROOF-MOUNTED PHOTOVOLTAIC m J 3O ARRAY.5:12(23°)SLOPED ROOF,7 PV MODULES (BLACK FRAME,BLACK BACKSHEET),257°AZIMUTH J < = 6 7 (N)AC COMBINER,OUTDOOR,OUTPUT CIRCUIT 0 � CONDUCTORS SHALL BE RUN IN PVC-40 CONDUIT 8 OVER ROOF NO CLOSER THAN 0.5"ABOVE ROOF SURFACE 0 (N)VISIBLE,LOCKABLE,READILY-ACCESSIBLE AC W W ® DISCONNECT LOCATED WITHIN 10 FT OF UTILITY I- Ch N METER,OUTDOOR 0 S 6O (E)UTILITY METER,OUTDOOR (N)TRANSITION BOX,OUTDOOR,OUTPUT CIRCUIT U9 O CONDUCTORS SHALL BE RUN IN FLEXIBLE STEEL CONDUIT THROUGH THE INTERIOR OF THE BUILDING , ► ,,,,t� SO (E)MAIN SERVICE PANEL(MSP),OUTDOOR ��k5�r��CENSF•;O" ROADWAY No 88991 •'9'�' = ALL ARRAY CIRCUITS SHALL BE ROUTED THROUGH *� •** _ THE INTERIOR OF THE BUILDING,AND WHERE SITE PLAN 10 POSSIBLE,ALONG THE BOTTOM OF LOAD BEARING E.-ø° STATE OF :/4s MEMBERS.NO CONDUIT SHALL BE INSTALLED ABOVE PV-2 SCALE: 1'=20' THE ROOF. ;��•'• FZ 0 R l0 P•:���'� " E S��NA y SITE PLAN DOC ID:154765-190719-1 DATE:3/3/21 CREATOR: REVIEWER: REVISIONS This layout is subject to change, but panels are never allowed to be placed on the fire safety pathways. The existing structure will be adequate for supporting the additional PV dead load and wind loads. PV-2 _, PV MODULE PM1-311 MODULES GENERAL ELECTRICAL P-154165 330W MICROINVERTER REF. QTY. MAKEAND MODEL PMAX PTC ISC IMP VOC VMP TEMP.COEFF.OF VOC FUSE RATING A A PM1-31 31 APTOS SOLAR DNA-120 330 330W 304W 10.51A 10.02A 40.3V 32.9V -0.123VFC(-0.31%1°C) 20A NOTES I !- 00 INVERTERS UTILITY HAS 24-HR UNRESTRICTED QTY. MAKE AND MODEL AC VOLTAGE GROUND RATED POWER MAX OUTPUT CURRENT MAX INPUT CURRENT MAX INPUT VOLTAGE CEC WEIGHTED EFFICIENCY ACCESS TO ALL PHOTOVOLTAIC '6N 11-31 31 MAKE 240V NOT SOLIDLYGROUNDED 240W-US1.0A 150A 48V 97.0% 1 SYSTEM COMPONENTS LOCATED AT rr1 ' Ig'5°:V ©A 8R NCH ?FNCH II DISCONNECTS OCPDS THE SERVICE ENTRANCE. I + 7 REF. QTY. MAKE 2UKtl OR RATED CURRENT MAX RATED VOLTAGE REF. QTY. F RATEDCURRENT MAX VOLTAGE CONDUCTORS EXPOSED TO __ SW1 ! EATON DG222UR8 OR EQUIV. 60A 240VAC 261-2 2 20A 240VAC r CB3 1 40A 240VAC SUNLIGHT SHALL BE LISTED AS SYSTEM SUMMARY NOTES 2 SUNLIGHT RESISTANT PER NEC BRANCH 1 BRANCH 2 ©THE DC AND AC CONNECTORS OF THE ENPHASE 1O7-60-2-US AND ARE LISTED TO MEET REQUIREMENTS ASA DISCONNECT MEANS AS ALLOWED BY NEC 690.15(D).MATING CONNECTORS SHALL COMPLY ARTICLE 300.6(C)(1)AND ARTICLE p S PER BRANCH 16 15 310.10(D). RRENT WITH NEC 690.33. 1^oA 15AJUNCTION BOX TPUT 3,840W 3,600W ® THE ENPHASE IQ7-60-2-US HAS ACLASS II DOUBLE-INSULATED RATINGAND DOES NOT REQUIRE GROUNDING ELECTRODE CONDUCTORS{GEC)OR EQUIPMENT GROUNDING CONDUCTORS(EGC).THE CONDUCTORS EXPOSED TO WETwL- J61 C POWER 10230W RATING INCLUDES GROUND FAULT PROTECTION(GFP).TO SUPPORT GFP,USE ONLY PV MODULES EQUIPPED WITH DC CABLES LABELED PV WIRE OR PV CABLE. LOCATIONS SHALL BE SUITABLE FORC POWER 9,434W 3USE IN WET LOCATIONS PER NEC 12 RRENT 31A ®ENPHASE SYSTEM MEETS REQUIREMENTS FOR PHOTOVOLTAIC RAPID SHUTDOWN SYSTEM(PVRSS),AS PER NEC 690.12(B). wWERWER 744oW ARTICLE 310.10(C).AC COMBINER C POWER OUTPUT 7,44000 ®MICROINVERTER BRANCH CIRCUIT CONDUCTORS ARE MANUFACTURED ENPHASE Q CABLES LISTED FOR USE IN 20A OR LESS CIRCUITS OF ENPHASE IQ MICROINVERTERS.THEY ARE ROHS,OIL Q L�) - 61 C62 A RESISTANT,AND UV RESISTANT.THEY CONTAIN TWO 12 AWG CONDUCTORS OF TYPE THHN/THWN-2 DRYMET AND CERTIFIED TO ULM03AND UL 9703. CYJ r- OA �A Cl GROUNDING NOTES Lu 1 ®DC PV CONDUCTORS ARE NOT SOLIDLYROUNDEDNO DC PVCONDUCTORSHBEWHITEOR GRAYOLORED G . ALL - C ALL EQUIPMENT SHALL BE 0 I 3 L.L ALL METAL ENCLOSURES,RACEWAYS,CABLES AND EXPOSED NONCURRENT-CARRYING METAL PARTS OF EQUIPMENT SHALL BE GROUNDED TO EARTH AS REQUIRED BY NEC 250.4(A)AND PART III OF 1 PROPERLY GROUNDED PER THE PV DISCONNECT ®ARTICLE 250 AND EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED ACCORDING TO NEC 690.45.THE GROUNDING ELECTRODE SYSTEM SHALL ADHERE TO NEC 690.47(A)AND NEC 250.169.THE DC REQUIREMENTS OF NEC ARTICLES W --� u<N1 GROUNDING ELECTRODE SHALL BE SIZED ACCORDING TO NEC 250.16"o AND INSTALLED IN COMPLIANCE WITH NEC 250.64. 250&690r - GSA I 4 PV MODULES SHALL BE GROUNDED <5 _ ®MAX DC VOLTAGE OF PV MODULE IS 432V AT 1°C(1°C-25°C)X-0.123V/C.40.27V=43.2V). TO MOUNTING RAILS USING MODULE 0 H UM 120V PANS ®AC AGGREGATION PANEL BUSBAR AND THE OVERCURRENT PROTECTION PROTECTING THE BUSBAR SHALL BE SIZED IN ACCORDANCE WITH NEC 705.12(BX2)(3)(C) LUGS OR RACKING INTEGRATED Cl) >- 40A CB3 (E)2401120Vip,3✓t L_� 2)0AMII1BR GROUNDING CLAMPS AS ALLOWED 2h1A MAIN BREAKER r APOINT-OF-CONNECTION IS ON LOADSIDEOFSERVICE DISCONNECT,INCOMPLIANCE WITH NEC705.12(BX2)(3)(B).OUTPUTISBACKFED THROUGH BREAKERIN MAIN PANEL. 2 BY LOCAL JURISDICTION.ALL OTHER W EXPOSED METAL PARTS SHALL BE LOADS I� M N (E)200A AA THE BREAKER SHALL BE LOCATED AT THE OPPOSITE END OF THE BUSBARFROMTHEMAINBREAKER.THEBREAKERSHALLNOTBEMARKEDFOR'LINE'AND*LOAD'. GROUNDED USING UL LISTED LAY-IN AC Q GEC cne A A PV SYSTEM DISCONNECT SHALL BE A VISIBLE KNIFE-BLADE TYPE DISCONNECT THAT IS ACCESSIBLE AND LOCKABLE BY THE UTILITY.THE DISCONNECT SHALL BE LOCATED WITHIN 10 FT OF UTILITY LUGS. IUTILITYMETER METER DISCONNECT SHALL INSTALLER SHALL CONFIRM THAT '^ II CONDUCTOR AND CONDUIT SCHEDULE W/ELECTRICAL CALCULATIONS MOUNTING SYSTEM HAS BEEN �J L EVALUATED FOR COMPLIANCE WITH CURRENT-CARRYING M� ID TYPICAL CONDUCTOR CONDUIT/CABLE CONDUCTORSIN OCPD EGG TEMP.CORR. CONY. DEBATED TERM. AMP.@TERM. 3 FILL FACTOR CURRENT BASEAMP UL 2703"GROUNDING AND BONDING" CONDUIT/CABLE FACTOR CURRENT (125%) AMP. TEMP.RATING TEMP.RATING WHEN USED WITH PROPOSED PV ��'*' J,,1," 1 10.5'DIA.FLEXIBLE 10 AWG THWN-2,COPPER STEEL 4 29A 12AWGTHWN-2,COPPER 0.76{54°C) 0.8 16A 20A 30A 18.24A 90°C 30A MODULE. .`� PANEL�(!Z �'. 2 1 WAWGTH 2 COPPER 0.5 DSTEELXIBLE �` cy�.•'�C E N5 ••�O 4 29A 12AWGTHWN-2,COPPER 0.76(54°C) 0.8 15A 1B.75A 30A 18.24A 90°C 30A IF THE EXISTING MAIN SERVICE STEEL 3 t SAWGTHWN-2 COPPER 0.75"DIAPVC 40 3 40A 8AWGTHWN-2,COPPER 0.96(34C) 1.0 31A 38.75A 75A 72A 75°C 65A PANEL DOES NOT HAVE A a No 88991 •• 4 1 8AWGTHWN-2 COPPER 0.75'DIAPVC-00 40A 5AWGTHWN-2,COPPER 0.96(34°C) 1.0 31A 38.75A 75A 72A 75°C 65A VERIFIABLE GROUNDING ' • •* 4 ELECTRODE, IT IS THE CONTRACTOR'S RESPONSIBILITY TO -o STATE OF :Q INSTALL A SUPPLEMENTAL ��O�'•.•F •��� GROUNDING ELECTRODE. �'.FS•��R1QQ•G��� AC SYSTEM GROUNDING -S, tiit ONAN��� ELECTRODE CONDUCTOR(GEC) 5 SHALL BE A MINIMUM SIZE#8AWG WHEN INSULATED,#6AWG IF BARE WIRE. EQUIPMENT GROUNDING SINGLE-LINE DIAGRAM CONDUCTORS SHALL BE SIZED ACCORDING TO NEC ARTICLE 690.45, 6 AND BEA MINIMUM OF#10AWG PROJECT ID: 154765 WHEN NOT EXPOSED TO DAMAGE, DATE: 03/03/21 AND#6AWG SHALL BE USED WHEN CREATED BY: SDT EXPOSED TO DAMAGE GROUNDING AND BONDING CHECKED BY: CONDUCTORS,IF INSULATED,SHALL REVISIONS 7 BE COLOR CODED GREEN,OR MARKED GREEN IF#4AWG OR LARGER SINGLE-LINE DIAGRAM C1-AC COMBINER LABELING NOTES P-154765 ENPHASE IQ COMBINER-) SEE NOTE N0.4(MSP) AC COMBINER PANEL(Cl) EACH DISCONNECTING MEANS FOR PHOTOVOLTAIC EQUIPMENT(SW1) ALL PLAQUES AND SIGNAGE REQUIRED BY 2017 NEC AND 2018 NFPA 1 WILL BE INSTALLED AS REQUIRED. `• WARNING I WARNING I LABELS,WARNING(S)AND MARKING SHALL COMPLY SW1-DISCONNECT • THIS EQUIPMENT FED BY MULTIPLE SOURCES. ELECTRIC SHOCK HAZARD.TERMINALS ON BOTH WITH ANSI Z535.4,WHICH REQUIRES THAT DANGER, EATON DG222URB I • ■■ TOTAL RATING OF ALL OVERCURRENT DEVICES, WARNING,AND CAUTION SIGNS USED THE STANDARD • • EXCLUDING MAIN OVERCURRENT DEVICE SHALL LINE AND LOAD SIDES MAY BE ENERGIZED IN 2 HEADER COLORS,HEADER TEXT,AND SAFE ALERT NOT EXCEED AMPACITY OF BUSBAR. THE OPEN POSITION. SYMBOL ON EACH LABEL.THE ANSI STANDARD TURN RAPID SHUTDOWN NEC705.12(B)(2)(3)(C) NEC690.13(B) REQUIRES A HEADING THAT IS AT LEAST 50%TALLER SWITCH TO THE'OFF' THAN THE BODY TEXT,IN ACCORDANCE WITH NEC POSITION TO SHUT DOWN 110.21(B). W MSP-MAIN SERVICE PANEL THE ENTIRE PV SYSTEM. AC SOLAR DISCONNECT(SWI,CB3 IN MSP) 5 AC DISCONNECT(SW1,CB3 IN MSP) A PERMANENT PLAQUE OR DIRECTORY SHALL BE I-- O O O O O INSTALLED PROVIDING THE LOCATION OF THE SERVICE Cf) W r 3 DISCONNECTING MEANS AND THE PHOTOVOLTAIC C SYSTEM DISCONNECTING MEANS IF NOT IN THE SAME LOCATION IN ACCORDANCE WITH NEC 690.56(B). LY < (Y)NFPA 111.12.2.1.1.1.1,11.12.2.1.4 AND NEC690.56(C)(1) LABEL(S)WITH MARKING,"TURN RAPID SHUTDOWN M SWITCH TO THE'OFF'POSITION TO SHUT DOWN THE J J ENTIRE PV SYSTEM,"SHALL BE LOCATED WITHIN 3 FT OF LL NEC690.13(B) NEC690.54 SERVICE DISCONNECTING MEANS THE TITLE SHALL UTILIZE CAPITALIZED LETTERS WITH A MINIMUM HEIGHT W U) KDANYAC ELECTRICAL PANEL THAT IS FED BY OF 3/8"IN BLACK ON A RED BACKGROUND,AND J J BOTH THE UTILITY AND THE PHOTOVOLTAIC 7 SOLAR BREAKER(MSP) REMAINING TEXT SHALL BE CAPITALIZED WITH A m SYSTEM(MSP) MINIMUM HEIGHT OF 3/16"IN BLACK ON WHITE ¢ Q = BACKGROUND L POW 0 U) I WARNING I I WARNING I (1) DUAER SOURCE.SECOND SOURCE IS INVERTER OUTPUT CONNECTION,DO N07 0 PHOTOVOLTAIC SYSTEM. RELOCATE THIS OVERCURRENT DEVICE. IJJ co W cr N NEC705.12(B)(3) NEC705.12(B)(2)(3)(B) NUEL Ru, "r, No 88991 '. * ^a'. STATE OF :•�Z sIQNA i'V;00%% SAFETY LABELS DOC ID:154765-190719-1 DATE:3/3/21 CREATOR: REVIEWER REVISIONS PV-4 ROOF PROPERTIES P-154765 ROOF MATERIAL COMPOSITION SHINGLE(1 LAYER) SLOPE 5/12(22.6°) MEAN ROOF HEIGHT 22.9FT DECK SHEATHING 15/32"OSB CONSTRUCTION TRUSSES(2X4 TOP-CHORD),241N OC RIDGE 75 MODULE MECHANICAL PROPERTIES i W MODEL APTOS SOLAR DNA-120 330 (- DIMENSIONS(AREA) 66.31N X 39.41N X 1.4IN(18.2 SQ FT) WEIGHT 41.9LB < MOUNTING SYSTEM PROPERTIES W J ç() I RAIL MODEL QUICK MOUNT PV QRAIL QMR-RL QUICK MOUNT PV QMLM FLASHED Q ANCHOR MODEL LOIN AIR GAP (FLASHED), J J m J FASTENING METHOD 3.5 INCH EMBEDMENT INTO TRUSSES J WITH(1)5/161N DIA.FASTENER MAX. O ALLOW.RAIL SPAN 72.01N(ZONE 1) /4 I 48.01N(ZONES 2 AND 3) I cO _ MAX.MOUNT SPACING 72.01N(ZONE 1) O 0 C- 48.OIN(ZONES 2 AND 3) W C W MAX.ALLOW. 23.81N(ZONE 1) cy N CANTILEVER 15.81N(ZONES 2 AND 3) GROUNDING AND INTEGRAL GROUNDING CERTIFIED I CD BONDING TO UL 2703 REQUIREMENTS y�� Ur DEAD LOAD CALCULATIONS PNUEI RU/2 EAVE c��.• �CENS••.O LOAD QTY LBS TOTAL LBS �k.•• •'L9 MODULES 12 41.9 502.7 :*`4;' No 88991 MICROINVERTERS 12 1,1 13.0 _ - LINEARFEET OF RAIL 82 FT 0.5 41.1 WIND ZONE I WIND ZONE II WIND ZONE III �-o; STATE OF :•Q7: ANCHORS 26 1.0 26.5 '���F••F�OR1C�p`••���.`� DISTANCE a IS EQUAL TO 10%OF THE BUILDING'S LEAST HORIZONTAL DIMENSION OR 40%OF THE MEAN ROOF HEIGHT,WHICHEVER IS SMALLER,BUT NOT LESS THAN 4%OF THE LEAST HORIZONTAL DIMENSION OR 3 FEET(ACSE 7- " r`'S O••••• c�` MISC.HARDWARE 11.4 11.4 10).THESE SETBACKS ARE APPLIED TO THE BUILDING FOOTPRINT AND PROJECTED TO THE PLANES OF ROOF CORNERS,RAKES,HIPS,EAVES,MANSARDS,AND RIDGES OF ROOF FACES. �Nq1�EN�. TOTAL ARRAY WEIGHT 594.7 LBS a=MAX(MIN(0.4*MEAN ROOF HEIGHT,0.1*LEAST HORIZONTAL DIMENSION), 0.04*LEAST HORIZONTAL DIMENSION,3 FT) AREA NAME QTY SQFT TOTAL SQFT 3.2 FT=MAX(MIN(0.4*22.9 FT,0.1*32.4 FT), 0.04*32.4 FT,3 FT) MODULES 112 18.2 218.4 ATTACHMENT POINT LOAD(594.7 LBS/26 ATTACHMENTS) 22.9 LBS ATTACHMENT PLAN (ORTHOGONAL PROJECTION PLAN DIST.LOAD(594.7 LBS/218.4 SQFT) 2.72 PSF . SCALE:3116"=1' DOC ID:154765-190719-1 NOTES DATE:3/3/21 CREATOR: TRUSS LOCATIONS ARE APPROXIMATE.ACTUAL REVIEWER: 1 LOCATIONS MAY DIFFER AND CONTRACTOR MAY NEED TO ADJUST MOUNT LOCATIONS.IN NO CASE SHALL THE REVISIONS MOUNT SPACING EXCEED"MAX.MOUNT SPACING" PV-5 . 1 ROOF PROPERTIES I P-154765 ROOF MATERIAL COMPOSITION SHINGLE(1 LAYER) SLOPE 5/12(22.6°) MEAN ROOF HEIGHT 13.9FT DECK SHEATHING 15/32"OSB CONSTRUCTION TRUSSES(2X4 TOP-CHORD),241N OC MODULE MECHANICAL PROPERTIES 75 w MODEL APTOS SOLAR DNA-120 330 DIMENSIONS(AREA) 66.31N X 39.41N X 1.41N(18.2 SQ FT) Co >- w < WEIGHT 41.9LB Co � W co MOUNTING SYSTEM PROPERTIES w RAIL MODEL QUICK MOUNT PV QRAIL QMR-RL 0 = RIDGE ANCHOR MODEL QUICK MOUNT QMLM(FLASHED), 3 LOIN AIR GAP J PV J m J FASTENING METHOD 3.5 INCH EMBEDMENT INTO TRUSSES ^ I- WITH(1)5/161N DIA.FASTENER O Cl) MAX.ALLOW. RAIL SPAN 72.01N(ZONE 1) (1) 48.OIN(ZONES 2 AND 3) MAX.MOUNT SPACING 48 72.01N(ZONE 1 DIN(ZONES 2 AND 3) a W N MAX.ALLOW. 23.8IN(ZONE 1) cy) CANTILEVER 15.81N(ZONES 2 AND 3) GROUNDINGAND INTEGRAL GROUNDING CERTIFIED CD BONDING TO UL 2703 REQUIREMENTS Ur +,`�ssssierrr��� DEAD LOAD CALCULATIONS PNLlEL RUI. LOAD QTY LBS TOTAL LBS EAVE y�`';•'��OE�SF''�2'� MODULES 7 41.9 293.2 *k'. No 88991 •* MICROINVERTERS 7 1.1 7,6 LINEAR FEET OF RAIL 48 FT 0.5 23.8 WIND ZONE I WIND ZONE I. LII WIND ZONE III -- ;•• STATE OF /��:` ANCHORS 17 1.0 17.4 ;��F•:,�O R l0 P•'��`;� MISC.HARDWARE 7,0 7.0 DISTANCE a IS EQUAL TO 10%OF THE BUILDING'S LEAST HORIZONTAL DIMENSION OR 40%OF THE MEAN ROOF HEIGHT,WHICHEVER IS SMALLER,BUT NOT LESS THAN 4%OF THE LEAST HORIZONTAL DIMENSION OR 3 FEET(ACSE 7- ";S / 10).THESE SETBACKS ARE APPLIED TO THE BUILDING FOOTPRINT AND PROJECTED TO THE PLANES OF ROOF CORNERS,RAKES,HIPS,EAVES,MANSARDS,AND RIDGES OF ROOF FACES. �1�"I'' TOTAL ARRAY WEIGHT 349.0 LBS a=MAX(MIN(0.4*MEAN ROOF HEIGHT,0.1*LEAST HORIZONTAL DIMENSION), 0.04*LEAST HORIZONTAL DIMENSION,3 FT) AREA NAME QTY SQFT TOTAL SQFT 3.2 FT=MAX(MIN(0.4'13.9 FT,0.1'32.4 FT), 0.04*32.4 FT,3 FT) MODULES 17 118.2 ,27.4 ATTACHMENT POINT LOAD(349.0 LBS/17 ATTACHMENTS) 20.5 LBS 1 ATTACHMENT PLAN (ORTHOGONAL PROJECTION PLAN DIST.LOAD(349.0 LBS/127.4 SQFT) 2.74 PSF - . SCALE: 1/4"= 1' DOC ID:154765-190719-1 NOTES DATE:3/3/21 CREATOR: TRUSS LOCATIONS ARE APPROXIMATE.ACTUAL REVIEWER: 1 LOCATIONS MAY DIFFER AND CONTRACTOR MAY NEED TO ADJUST MOUNT LOCATIONS.IN NO CASE SHALL THE REVISIONS MOUNT SPACING EXCEED"MAX.MOUNT SPACING" -1 PV-5.2 ROOF PROPERTIES P-154765 ROOF MATERIAL COMPOSITION SHINGLE(1 LAYER) SLOPE 5/12(22.6°) MEAN ROOF HEIGHT 22.9FT DECK SHEATHING 15/32"OSB CONSTRUCTION TRUSSES(2X4 TOP-CHORD),241N OC RIDGE MODULE MECHANICAL PROPERTIES I w MODEL APTOS SOLAR DNA-120 330 ui DIMENSIONS(AREA) 66.31N X 39.4IN X 1.41N(18.2 SQ FT) Cl) W Cl) > - WEIGHT 41.9LB M MOUNTING SYSTEM PROPERTIES ti% W -' O � - RAIL MODEL QUICK MOUNT PV QRAIL QMR-RL RIDGE QUICK MOUNT PV QMLM(FLASHED), J J ANCHOR MODEL m J LOIN AIR GAP FASTENING METHOD 3.5 INCH EMBEDMENT INTO TRUSSES WITH(1)5/161N DIA.FASTENER oac 72.01N(ZONE 1) I 0 Cl) MAX.ALLOW.RAIL SPAN 48 01N(ZONES 2 AND 3) i Cl) _ 0 � 0- MAX.MOUNT SPACING 72.OIN(ZONE 1) SAVE W C) N 48.DIN(ZONES 2 AND 3) I M MAX.ALLOW. 23.81N(ZONE 1) 0 CANTILEVER 15.81N(ZONES 2 AND 3) GROUNDING AND INTEGRAL GROUNDING CERTIFIED BONDING TO UL 2703 REQUIREMENTS fJ WIND ZONE I a WIND ZONE II WIND ZONE III 0 DEAD LOAD CALCULATIONS DISTANCE a IS EQUAL TO 10%OF THE BUILDING'S LEAST HORIZONTAL DIMENSION OR 40%OF THE MEAN ROOF HEIGHT,WHICHEVER IS SMALLER,BUT NOT LESS THAN 4%OF THE LEAST HORIZONTAL DIMENSION OR 3 FEET(ACSE 7- 'R(//����� 10).THESE SETBACKS ARE APPLIED TO THE BUILDING FOOTPRINT AND PROJECTED TO THE PLANES OF ROOF CORNERS,RAKES,HIPS,EAVES,MANSARDS, �`j`P'•CENS •••••• I� �� LOAD QTY LBS TOTAL LBS AND RIDGES OF ROOF FACES. ��5..•� F•:O,L9•� a=MAX(MIN(0.4*MEAN ROOF HEIGHT,0.1*LEAST HORIZONTAL DIMENSION), 0.04*LEAST HORIZONTAL DIMENSION,3 FT) i�"�• No 88991 •: MODULES 12 41.9 502.7 3.2 FT=MAX(MIN(0.4*22.9 FT,0.1*32.4 FT), 0.04*32.4 FT,3 FT) MICROINVERTERS 12 1.1 13.0 • LINEAR FEET OF RAIL 83 FT 0.5 41,3 -a• STATE OF :4 1 ATTACHMENT PLAN (ORTHOGONAL PROJECTION ••. oR`o•• ,�;: ANCHORS 25 1.0 25.5 MISC.HARDWARE 11.3 11.3 V-5.3 SCALE: 118"_ 1' ''''III'"' �•• TOTAL ARRAY WEIGHT 593.7 LBS AREA NAME QTY SQFT TOTAL SQFT MODULES 12 18.2 218.4 ATTACHMENT POINT LOAD(593.7 LBS/25 ATTACHMENTS) 23.7 LBS P LAN DIST.LOAD(593.7 LBS/218.4 SQFT) 2.72 PSF DOC ID:154765-190719-1 NOTES DATE:3/3/21 CREATOR. TRUSS LOCATIONS ARE APPROXIMATE.ACTUAL REVIEWER: 1 LOCATIONS MAY DIFFER AND CONTRACTOR MAY NEED TO ADJUST MOUNT LOCATIONS.IN NO CASE SHALL THE REVISIONS MOUNT SPACING EXCEED"MAX.MOUNT SPACING" PER ENGINEERING,CANTILEVER("RAIL END 2 OVERHANG")IS NOT TO EXCEED 33%OF ACCEPTABLE RAIL SPAN"DEFINED IN THIS DOCUMENT AS"MAX. ALLOW.RAIL SPAN". PV-5.3 MOUNTING SYSTEM NOTES r -154765 i FLASHING SHALL BE APPLIED IN ACCORDANCE WITH MANUFACTURERS'INSTRUCTIONS. IF THERE IS ANY CONFLICT BETWEEN WHAT IS DEPICTED HERE AND INSTRUCTIONS 2 PROVIDED BY A MANUFACTURER,THE MANUFACTURER'S INSTRUCTIONS SHALL SUPERCEDE. RAIL CLAMPING ZONE f f �% (I)QMPV UNIVERSAL /'-- -� W MID CLAMP >.`i -ROOF FRAMING PV MODULE , W J /� �l QMPV QRAIL LIGHT J PV MODULE �` �\ - L.L W W Cn COMP.SHINGLE-� w O �� ROOFING � SLIDE FLASHING UNDER THE 3RD COURSE OF SHINGLES 0 PV 6 !�',' LJJ W ROOF UNDERLAYMENT .:� /-- ROOF FRAMING M N ROOF DECKING <- '� -----�` LAG/STRUCTURAL SCREWS EMBEDDED INTO ROOF FRAMING / A RACKING ELEVATION (TRANSVERSE VIEW) ATTACHMENT DETAIL (TRANSVERSE VIEW) "111"'''� NPV-6 SCALE: NTS P N�.�Pr1UELRU�Zo.,�� P` 6 SCALE: NTS ' 9 "- �` , �': No 88991 .4 PV PV MODULE '�'. STATE OF :•�: QMPV UNIVERSAL-, J QMPV UNIVERSAL MID CLAMP ,—PV MODULE �O•'• ,c •�t.�`': END CLAMP :'�` �ORiDP•'•���� QMPV QRAILLIGHT—, "1— /! ^ `v =1 / / COMP.SHINGLE • - ROOFING QMPVQRAILk J U QMLM/QMLM-ST) ATTACHMENT LIGHT DETAILS -ROOF DECKING I COMP.SHINGLE D` j/ DOC ID:154765-190719-1 ROOFING N / ,' INSTALL FLASHING DATE:3/3121 ROOF FRAMING SPACING R- ROOF UNDERLAYMENT�' / f \ , CREATOR: ATTACHMENT SPAN -ROOF FRAMING ROOF DECKING_1<... ,/ �` ' ,LAG/STRUCTURAL SCREWS REVIEWER: ROOF FRAMING-' - - - -- EMBEDDED INTO ROOF REVISIONS FRAMING 7g RACKING ELEVATION (LONGITUDINAL VIEW ("i5 ATTACHMENT DETAIL (LONGITUDINAL VIEW) SCALE: NTS SCALE: NTS PV-6 N GENERAL NOTES P-154755 ACCESS AND SPACING REQUIREMENTS SHALL BE 2 1 REQUIRED TO PROVIDE EMERGENCY ACCESS TO THE ROOF,PROVIDE PATHWAYS TO SPECIFIC AREAS OF THE ROOF,PROVIDE FOR SMOKE VENTILATION OPPORTUNITY AREAS,AND TO PROVIDE EMERGENCY EGRESSION FROM THE ROOF.THE AHJ SHALL BE 3 2 PERMITTED TO REDUCED OR MODIFY ROOF ACCESS BASED UPON FIRE DEPARTMENT VENTILATION PROCEDURES ORALTNERATIVE METHODS THAT 4 ENSURE ADEQUATE FIRE DEPARTMENT ACCESS, PATWAYS,AND SMOKE VENTILATION.(NFPA 1 11.12.2.2.1) LJJ 4 5 1 NOT LESS THAN TWO 36 IN.(914 MM)WIDE PATHWAYS Cl) L1J ON SEPARATE ROOF PLANES,FROM GUTTER TO RIDGE, >- > SHALL BE PROVIDED ON ALL BUILDINGS.ONE PATHWAY (j) Lo SHALL BE PROVIDED ON THE STREET OR DRIVEWAY SIDE OF THE ROOF.FOR EACH ROOF PLAN WITH A PV M 6 - 2 J ARRAY,A36 IN.(914 MM)WIDE PATHWAY FROM GUTTER W J 2 TO RIDGE SHALL BE PROVIDED ON THE SAME ROOF I_L. 7 PLANE AS THE PV ARRAY,ON AN ADJACENT ROOF 1 PLANE OR STRADDLING THE SAME AND ADJACENT ROOF PLANES.PATHWAYS SHALL BE LOCATED IN _ J J AREAS WITH MINIMAL OBSTRUCTIONS SUCH AS VENT 1 4 PIPES,CONDUIT,OR MECHANICAL EQUIPMENT.(NFPA 1 m J 11.12.2.2.2.1) 3 FOR PV ARRAYS OCCUPYING UP TO 33 PERCENT OF THE 0 Cl) PLAN VIEW ROOF AREA,A MINIMUM 18 IN.(457 MM) Cl) 1 6 4 PATHWAY SHALL BE PROVIDED ON EITHER SIDE OF A çj- 3 HORIZONTAL RIDGE.FOR PV ARRAYS OCCUPYING MORE 0 THAN 33 PERCENT OF THE PLAN VIEW ROOF AREA,A W U J MINIMUM OF 36 IN.(914 MM)PATHWAY SHALL BE M N PROVIDED ON EITHER SIDE OF A HORIZONTAL RIDGE. (NFPA 111.12.2.2.2.2) 0 8 � 1O ROOF ACCESS POINT 2O 1.5 FT.WIDE FIRE ACCESS PATHWAY ` NIJEL RU//', PV MODULES INSTALLED ON ROOF WITH QUICK MOUNT c�`�;•'ti�CENSF•,O,L PV QRAIL MOUNTING SYSTEM.THE MOUNTING SYSTEM 3O IS UL 1703 CLASS A FIRE RATED ON A 5/12 SLOPED =*�: No 88991 •'9*'_ • ROOF WHEN INSTALLED WITH TYPE 1 OR 2 MODULES. - * ; = THE APTOS SOLAR DNA-120 330 IS TYPE 1. _ ' = 1 'FIRE •SAFETY PLAN 3.0 FT.WIDE SMOKE-VENTILATION SETBACK,PER NFPA �'° STATE pF :�� PV-7 SCALE: 1'=20' 0 111.12.2.2.2.2 ;�0�;•,•a�OR��Q ;�w�`': PV MODULES INSTALLED ON ROOF WITH EVEREST r`SS O ' • N��`�`, CROSSRAIL MOUNTING SYSTEM.THE MOUNTING //l NA Elt�` Irrili+{ O5 SYSTEM IS UL 1703 CLASS A FIRE RATED ON A 5/12 SLOPED ROOF WHEN INSTALLED WITH TYPE 1,2, OR 3 MODULES.THE APTOS SOLAR DNA-120 330 IS TYPE 1. O3.0 FT.WIDE FIRE ACCESS PATHWAY,PER NFPA 1 Fl REPS�AFETY 11.12.2.2.2.1 O7 N 0.5 FT.WIDE FIRE ACCESS PATHWAY DOC ID:154765-190719-1 OS ROADWAY DATE:3/3/21 TOTAL PLAN VIEW ARRAY AREA IS 533.6 SQ.FT,WHICH CREATOR: 9 REPRESENTS 27.3%OF TOTAL PLAN VIEW ROOF AREA REVIEWER: (1954.0 SQ.FT) THIS SYSTEM UTILIZES MICROINVERTERS.THERE ARE REVISIONS 10 NO DC CIRCUITS OUTSIDE OF THE ARRAY PERIMETER OR INSIDE THE BUILDING. Pv-7 A • s ��,' •�• o 0 • C =D:� m * z, - t- DNA- 120 ALL - BLACK DNA 1 20 . 4 =•,_ 330W I 325W 1 320W aptos lar Lechnoiogy • ♦ f �� ■ DNA-'20-MF23-320W DNA-r20-MF23-325W DNA'20-MF23-"s30W STCrated output Pmpp(W) 320 325 330 a 73.9 rT Module Efficiency 18.96% 19.25% 19.54% Open Circuit Voltage V.c0(V) 39.92 40.10 40.27 S .rwre NW.pewA' N!9 Short Circuit Current Isc(A) 10.35 10.43 10.51 A.....r.....t•wAA .r: Rated Voltage Vmmp(V) 32.51 32.71 32.91 ` ..•....w.3».M• Rated Current I (A) 9.84 9.93 10.02 Standard Test Conditions for front-face of panel: 0 t 1000 W/m2,25°C,measurement uncertainty≤3% • a '° Div » a a ■ ■ A ■ , Temperature Coefficients Pmpp -0.40%/°C Temperature Coefficients I.. +0.046%/°C Cell Type Monocrystalline Temperature Coefficients V. -0.306%/°C Glass Low Iron,Tempered R'9r .areLsiiii ! ! f ! Normal Operating Cell ° Temperature(NOCT) 45°C Frame Anodized Aluminum Alloy OPERATING i = Junction Box IP67 Maximum Series Fuse 20A Dimension 1684 x 1002 x 35mm ' • -• - • .• ••. ■- • Output Cable 4mm'(EU)12AWG, Maximum System Voltage 1,500 VDC(UL&IEC) p 39.37in(1000mm) Maximum Load Capacity(Per 5,400PA Snow Load Weight 41.9lbs.(19kg) UL1703) 175mph Wind Rating - - • • • Fire Performance Class Class C/Type 1 Cable Length 1200mm liii A II 1.1 X11 ' • •. • Number of Modules per Pallet 30 • • • • • Number of Pallets per 40ft HQ 26 Container Pallet Dimensions(mm) 1720X 1140 X 1140 �` - •-• .• = Pallet weight(kg) 620 Container weight(kg) 16120 PRODUCT ' 1 . .• • L'SIEO r1AC tae_a C'.,Z Blvd Ste 2 .., aanta Clara.CA.1- 054 A. CD2mm 35mm 952mm • • DtlA-120-MF23-XXXW Aptos Solar Technology reserves the right to make specification changes w'thout notice REST EN'[AL COMMERCIAL 1111f/!I// `0�) u, 0 _ •• •,l/v2 * cc z:r �r :p 0 c y-C iC• �0� Enphase Enphase IQ 7 and IQ 7+ Microinverters ''f�/111Itt�'` Enphase Microinverters :' •;.` J, a INPUT DATA(DC) __ IQ7-60-2-US I IQ7-60-B-US IQ7PLUS-72-2-US 11Q7PLUS-72-B-US Commonly used module pairings' 235W-350W+ ' 235 W-440 W+ Module compatibility 60-cell PVrnodules only 60-cell and 72-cell PV modules Maximum input DC voltage 48V 60V Peak power tracking voltage 27 V-37 V 27 V-45 V Operating range 16V-48V 16V-60V Min/Max start voltage 22 V y 48 V 22V/60V Max DC short circuit current(module Ise) 15A 15 A Enphase The high-powered smart grid-ready Overvoltage class DC port II II Enphase IQ 7 Micro' and Enphase IQ 7+Micro DC port backfeed current DA 0 A PV array configuration 1 x 1 ungrounded array;No additional DC side protection required; 7 and IQ 7+ dramatically simplify the installation process while AC side protection requires max 20A per branch circuit achieving the highest system efficiency. OUTPUT DATA(AC) IQ 7 Microinverter IQ 7+Microinverter Microinverters Peak output power 250 VA 295 VA Part of the Enphase IQ System,the IQ 7 and Maximum continuous output power 240 VA 290 VA IQ 7+Microinverters integrate with the Enphase Nominal(L-L)vohage/range2 240 VI 208V! 240V/ 208V/ 211-264V 183-229V 211-264 V 183-229V IQ Envoy",Enphase IQ Battery',and the Enphase Maximum continuous output current 1.04(2401/) 1.15 A(208 V) 1.21 A(240V) 1.39A(208V) Enlighten' monitoring and analysis software. Nominal frequency 6D Hz 60 Hz Extended frequency rarge 47-58 Hz 47-68 Hz IQ Series Microinverters extend the reliability AC short circuit fault current over 3 cycles 5.8 Arms 5.8 Arms Maximum units per 20 A(L--L)branch circuits 16(240 VACj 13(208 VAC) 13(240 VAC) 11(208 VAC) standards set forth by previous generations and Overvoltageclass AC port ;l= Ill undergo over a million hours of power-on testing, AC port backfeed ctrren! 0 A 0 A enabling Enphase to provide an industry-leading Power factor setting 1.0 1.0 Power factor{adjustable) 0.85 leading...D.85lagging 0.85 leadin ...0.85 lagging warranty of up to 25 years. EFFICIENCY @240 V @208 V @240 V @20811 Peak efficiency 9 .6% 97.6% 97.5% 97.3% CEO weighted efficiency 97.0% 97.0% 97.0% 97.0% _ MECHANICAL DATA Ambient temperature range -40"Cto+65uC Relative humidity range 4%to 100%(condensing) Easy to Install Connector type(IQ7-60-2-US&io7PLUS 72-2-US) MC4(or Amphenol H4 UTX with additional Q-DCC-5 adapter) • Lightweight and simple Connectortype(IQ7-60-B-US 81o7P1i S-72-B=J5j Friends PV2(MC4 intermateable). Adaptors for modules with MC4 or UTX connectors: • Faster installation with improved,lighter two-wire cabling -PV2to MC4:order ECA-520-S22 -PV2 to UTX:order ECA-320-S25 Built-in rapid shutdown compliant(NEC 2014&2017) Dimensions(WxHxD) 212 mm x 175 mm x 30.2 mm(without bracket) Weight 1.08 kg(2.38 Ibs) Productive and Reliable Cooling Natural convection-No fans Approved for wet locations Yes • Optimized for high powered 60-cell and 72-cell*modules Pollution degree PD3 • More than a million hours of testing Enclosure Class II double-insulated,corrosion resistant polymeric enclosure • Class II double-insulated enclosure Environmental category/UV exposure rating NEMA Type 6!outdoor UL listed FEATURES Communication Power Line Communication(PLC) Monitoring Enlighten Manager and MyEnlighten monitoring options. Smart Grid Ready Both options require installation of an Enphase IQ Envoy. Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load-break Complies with advanced grid support,voltage and disconnect required by NEC 690. frequency ride-through requirements Compliance CA Rule 21(UL 1741-SA) • Remotely updates to respond to charging UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B, ICES-0003 Class B, grid requirements CAN/CSA-C22.2 NO.107.1-01 Configurable for varying grid profiles This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems,for AC • Meets CA Rule 21(UL 1741-SA) and DC conductors,when installed according manufacturer's instructions. UL *The IQ 7+Micro i3 required to support 72-cell modules. 1.No enforced DC/AC ratio.Seethe compatibility calculator at httos//enohase com/en-us/support/module-com atibili 2.Nominal voltage range can be extended beyond nominal if required by the utility. 3.Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. p EN PHASE. To learn more about Enphase offerings,visit enphase.com EN PHASE. To iearn n-ore a ut En ase offer117 S,"/751#en haSe. m CO +7 2018 Enpna a Energy.t eights teser red,f trademarks or;•a ds-rt are the crocerty of Enphase E erg 2018-1119 { •. T ____ ITM QRai — Fully Integrated Mounting and Racking System Fast, Simple Installation: It Just Clicks The QRail Series is a strong and versatile solar array mounting system that provides unrivaled benefits to solar QCIickTechnologyrM designers and installers.Combined with Quick Mount PV's industry-leading waterproof mounts,QRail offers a The universal mid and end clamps use patented QClick complete racking solution for mounting solar modules on any roof, technology to simply"click" into the rail channel and _+ remain upright, ready to accept the module.The ° Easily design array configurations with the QDesign software pre-assembled clamps fit virtually all module frames and ii �,— application.Generate complete engineering reports and calculate require no extra hardware,eliminating pre-loading and --tr5e- a precise bill of materials for all the mounting, racking and reducing installation time. accessories needed for a complete solar array. --� UNIVERSAL END CLAMP UNIVERSAL BONDED MID CLAMP 1 �� 2 3 2 clamps for modules from 2 clamps for modules from 30-45mm or38-50mm thick 30-45mm or 38-50mm thick Corn pre ensive, One-Source Solution Installing isaseosyas1-2-3 click! QRail,together with Quick Mount PV's waterproof mounting products, provides the benefit of a single-sourced, QS1IiCe Technology seamlessly integrated rooftop installation that works with all roof types—composition/asphalt shingles, QRail's innovative internal QSplice installs in seconds, requiring no flat or curved tile, metal shingle,shake,slate and low slope roofs.The QRail system also works with any roof tools or screws.Simply insert QSplice into the rail and slide the other attachment system for maximum flexibility, rail on to create a fully structural, bonded splice.An external splice is WQSIIIICI also available. Superior Strength and Versatility 1 2 3 QRail is engineered for optimal structural performance.The system is certified to UL 2703,fully code compliant and backed by a 25-year H Installs in seconds—no tools or hardware required warranty.QRail is available in Light,Standard and Heavy versions to with match all geographic locations.QRail is compatibleSTANDARD virtually all Fully Integrated Electrical Bonding modules and works on a wide range of pitched roof surfaces. Modules LIGHT QRails come in two lengths— The QRail system provides an integrated electrical bonding path,ensuring that all exposed metal parts and can be mounted in portrait or landscape orientation in standard or 168 inches(14 ft)and 208 inches(17.3 ft) the solar module frames are electrically connected.All electrical bonds are created when the components are shared-rail configurations. Mill and Block Finish installed and tightened down.. ........ i lII1//,/ ITEM • THIS EDGE TOWARDS ROOF RIDGE NO. DESCRIPTION QTY. o 1 FLASHING, ROUNDED CORNERS, 9�" X 12" X .040", .438" HOLE, 5052, 1 9 0 *MIL c`` o 2 L-FOOT, 2" X 3.30" FOR .438" O.D. FASTENER, 2-1/16" SLOT, 6061- 1 6/6005A T61, MILL 3 WASHER, SEALING, 5/16" ID X 3/4" OD, EPDM BONDED SS 1 4 LAG SCREW, HEX HEAD, 5/16" x4", 18-8SS 1 *5 STRUCTURAL SCREW, QMPV, T-30 HEX WASHER HEAD, 5/16" X 4-1/2", 1 18-8SS 12.00 *5 4 3.00 ( 4.20 ) 3 * STRUCTURAL SCREW AVAILABLE ON QMLM-ST 4.50 I VERSIONS ONLY 9.00 2 I 2.00 1 .00 C� .397 8 2.09 1 AVAILABLE IN MILL, AND BLACK FINISHES +040U c Mount P 4f f - TITLE: 13.541 ( 2.50 ) 2 75 4.04 QMLM & QMLM-ST: L-MOUNT, .1 - 2-1 /16" SLOT QMLM QMLM-ST UNLESS OTHERWISE SPECIFIED: SIZE DRAWN BY: RAD REV DIMENSIONS ARE IN INCHES TOLERANCES: A DATE: 7/16/2018 9 PROPRIETARY AND CONFIDENTIAL FRACTIONAL± 1/8 THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF QUICK MOUNT PV. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE DO NOT SCALE DRAWING TWO PLACE DECIMAL ±.19 WRITTEN PERMISSION OF QUICK MOUNT PV IS PROHIBITED. COPYRIGHT©2016 QUICK MOUNT PV THREE PLACE DECIMAL ±.094 SCALE: 1:4 WEIGHT:1.0723 SHEET 1 OF 1