Loading...
HomeMy WebLinkAbout21-1688 D r;uiiidn City of Zephyrhills PERMIT NUMBER 5335 Eighth Street '..- Zephyrhills, FL 33542 ELCMISC-001688-2021 Phone: (813)780-0020 Fax: (813)780-0021 Issue Date: 03/17/2021 Permit Type: Electric Service Replacement/Misc Property Number Street Address 26 25 210140 00200 0010 8100 Wheat Stone Drive Owner Information Permit Information Contractor Information Name: ALLEN PETRIE Permit Type:Electric Service Replacement/M Contractor: US SOLAR Class of Work:Add/Alter Residential Address: 8100 Wheat Stone Dr Building Valuation:$28,252.00 ZEPHYRHILLS,FL 33540 Electrical Valuation:$5,000.00 Phone: (813)480-4654 Mechanical Valuation: Plumbing Valuation: Total Valuation:$33,252.00 Total Fees:$246.26 Amount Paid:$246.26 Date Paid:3/17/2021 1:15:21 PM Project Description INSTALLATION ROOF MOUNT SOLAR Application Fees Building Permit Fee $181.26 Electrical Permit Fee $65.00 REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each subsequent reinspection. Notice: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permit required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property.If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications add fee Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. alaL4-)L-Jrn CONT CTOR SIGNATURE PE IT OFFICE PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department / �1 Date Received ( pone Contact for Permitting ( 813 ) 947 _ 2521 Owner's Name -Ai" Petrie Owner Phone Number (813) 480 - 4654 Owner's Address 1 8100 Wheat Stone Drive,Zephyrhills, Florida 33540 Owner Phone Number Fee Simple Titleholder Name Owner Phone Number Fee Simple Titleholder Address JOB ADDRESS 8100 Wheat Stone Drive, Zephyrhills, Florida 33540 LOT# Q SUBDIVISION &4A ZEPHYR LAKES PH 1A,2A,2B SUBDIVISION A PARCEL ID# 26-25-21 -0140-00200-0010 (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED R NEW CONSTR 8 ADD/ALT = SIGN = DEMOLISH INSTALL REPAIR PROPOSED USE SFR COMM = OTHER TYPE OF CONSTRUCTION BLOCK 0 FRAME = STEEL DESCRIPTION OF WORK ROOF MOUNTED SOLAR PANEL INSTALL BUILDING SIZE SQ FOOTAGE HEIGHT BUILDING $ 28,252 VALUATION OF TOTAL CONSTRUCTION ELECTRICAL $ 5,000 1AMP SERVICE = PROGRESS ENERGY 0 W.R.E.C. PLUMBING $ =MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION =GAS ROOFING 0 SPECIALTY = OTHER " FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES NO BUILDER COMPANY US SOLAR SIGNATURE REGISTERED Y/N FEE CURREN Address 2732 Broadway Center BLVD.Brandon,FL 33510 License# CVC57002 ELECTRICIAN v COMPANY GENESIS ELECTRIC SERVICES LLC. SIGNATURE REGISTERED Y/N FEE CURREN Address 2825 Murray Pass, Odessa FL 33556 License# EC 13007122 PLUMBER COMPANY E_ SIGNATURE REGISTERED Y/N FEE CURREN Y/N Address License# MECHANICAL COMPANY SIGNATURE REGISTERED Y/N FEE CURREN Address I License# OTHER COMPANY SIGNATURE REGISTERED Y/N J FEE CURREN Y/N Address License# iftlt[ tll�iill ilttlilEt<iElillttEi� � �i1i�#I�te� lt€It€ t10 ���t1I111 �I�i ���it1 � �1t �ltllEYi 1E ;f�t€I3 RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date.Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster;Site Work Permit for subdivisions/large projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms. R-O-W Permit for new construction. Minimum ten_(10)working:days•after submittal date.Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1,dumpster.,Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT '_ :Attach.'(2):sets,of Engineered'kl ns. •. **** � PROPERTYiSURVEY;required:for all NEW construction. 4 Directions:.._ .... Fill out application completely. ""' Owner&Contractor sign back of application,notarized If over$2500,a Notice of Commencement is required.(A/C upgrades over$7500) ** Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (Copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C. Fences(Plot/Survey/Footage) Driveways-Not over Counter if on public roadways..needs ROW Solar Local Experts who Care 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department i NOTICE OF DEED RESTRICTIONS:The undersigned understands that this permit may be subject to"deed"restrictions"which may be more restrictive than County regulations.The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES:If the owner has hired a contractor or contractors to undertake work,they may be required to be licensed in accordance with state and local regulations.If the contractor is not licensed as required by law,both the owner and contractor may be cited for a misdemeanor violation under state law.If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work,they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847-8009. Furthermore,if the owner has hired a contractor or contractors,he is advised to have the contractor(s)sign portions of the"contractor Block"of this application for which they will be responsible.If you,as the owner sign as the contractor,that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES:The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings,change of use in existing buildings,or expansion of existing buildings,as specified in Pasco County Ordinance number 89-07 and 90-07,as amended.The undersigned also understands,that such fees,as may be due,will be identified at the time of permitting.It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a"certificate of occupancy"or final power release.If the project does not involve a certificate of occupancy or final power release,the fees must be paid prior to permit issuance.Furthermore,if Pasco County Water/Sewer Impact fees are due;they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713,Florida Statutes,as amended):If valuation of work is$2,500.00 or more,I certify that I,the applicant, have been provided with a copy of the"Florida Construction Lien Law—Homeowner's Protection Guide"prepared by the Florida Department of Agriculture and Consumer Affairs.If the applicant is someone other than the"owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner"prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT:I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction,zoning and land development.Application is hereby made to obtain a permit to do work and installation as indicated.I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction,County and City codes,zoning regulations,and land development regulations in the jurisdiction.I also certify that I understand that the regulations of other government agencies may apply to the intended work,and that it is my responsibility to identify what actions I must take to be in compliance.Such agencies include but are not limited to: - Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands,Water/Wastewater Treatment. - Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. - Army Corps of Engineers-Seawalls, Docks, Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. - US Environmental Protection Agency-Asbestos abatement. - Federal Aviation Authority-Runways. I understand that the following restrictions apply to the use of fill: - Use of fill is not allowed in Flood Zone W" unless expressly permitted. - If the fill material is to be used in Flood Zone "A", it is understood that a drainage, plan addressing a "compensating volume" will be submitted at time of permitting which is prepared by a pr,,ofessional engineer licensed by the State of Florida. - If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction, I certify that fill will be used only to fill the area within the stem wall. - If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill, an engineered drainage plan is required. If I am the AGENT FOR THE OWNER,I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work,plumbing,signs,wells,poolsi air conditioning,gas,or other installations not specifically included in the application.A permit issued shall be construed to be a license to proceed with the work and not as authority to violate,cancel,alter,or set aside any provisions of the technical codes,nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans,construction or violations of any codes.Every permit issued'shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance,or if work authorized by the permit is suspended for abandoned for a period of six(6)months after the time the work is commenced.An extension may be requested,in writing,from the Building Official for a period not to exceed ninety(90)days and will demonstrate justifiable cause for the extension.If work ceases for ninety(90)consecutive days,the job is considered abandoned. I WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY(RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YQUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NQTI COMMENCE I MENT. FLORIDA JURAT(F.S.117.03) I OWNER OR AGENT CONTRACTOR Subscribed and sworn to(or affirmed)before me this Subscribed and sworn to(or affirmed)before me this by 03/10/2021 by Seann Gates Who is/are personally known to me or has/have produced Who is/are personallyy known to me or has/have produced as identification. DL as identification. ,I i Notary Public Notary Public Commission No. Commission No. GG 959064 Jason S. Monchgesang Name of Notary typed,printed or stamped Name of Notary typed,printed or stamped E JASON S. MONCHGESANG Notary Public-State of Florida Commission#GG 959064 �� My Commission Expires `� February 17, 2024 olar Local Experts who Care Docu51gn Envelope ID:D3(:75B2E-F(;50-46D0-9276-573FEEBDC381 CONTRACT FOR SALE AND INSTALLATION OF A 7.69 SYSTEM (hereinafter the"System")by and between US Solar Squared,LLC(hereafter"Seller"whose address is below provided)and Amy Petrie Allen Petrie (hereinafter jointly or severally`Buyer")whose address is Qt nn wheat Stone Drive Zephyrhills Florida 33540 according to the terms and conditions hereafter stated. Buyer understands and agrees that this contract is binding only when accepted by Seller by having its duly authorized company officer or member execute this contract.Buyer further understands and agrees that the full contract price for purchase and installation of the System shall be the following price $33,252.00 unless amended by subsequent agreement of the parties. Buyer further acknowledges and agrees that Buyer is not to give the sales agent presenting me this contract any money or check as the sales agent is an independent contractor and is not authorized to collect money on behalf of Seller. TERMS AND CONDITIONS MECHANIC'SLIENNOTICE: ACCORDING TO FLORIDA'S CONSTRUCTION LIEN LAW (SECTIONS 713.001 - 713.37, FLORIDA STATUTES),THOSE WHO WORK ON YOUR PROPERTY OR PROVIDE MATERIALS AND ARE NOT PAID IN FULL HAVE A RIGHT TO ENFORCE THEIR CLAIM FOR PAYMENT AGAINST YOUR PROPERTY IF YOUR CONTRACTOR OR SUBCONTRACTOR FAILS TO PAY SUBCONTRACTORS, SUBSUBCONTRACTORS, OR MATERIAL SUPPLIERS. THE PEOPLE WHO ARE OWED MONEY MAY LOOK TO YOUR PROPERTY FOR PAYMENT, EVEN IF YOU HAVE ALREADY PAID YOUR CONTRACTOR IN FULL. IF YOU FAIL TO PAY YOUR CONTRACTOR, YOUR CONTRACTOR MAY ALSO HAVE A LIEN ON YOUR PROPERTY. THIS MEANS IF A LIEN IS FILED YOUR PROPERTY COULD BE SOLD AGAINST YOUR WILL TO PAY FOR LABOR, MATERIALS, OR OTHER SERVICES THAT YOUR CONTRACTOR OR A SUBCONTRACTOR MAY HAVE FAILED TO PAY. TO PROTECT YOURSELF, YOU SHOULD STIPULATE IN THIS CONTRACT THAT BEFORE ANY PAYMENT IS MADE, YOUR CONTRACTOR IS REQUIRED TO PROVIDE YOU WITH A WRITTEN RELEASE OF LIEN FORM ANY PERSON OR COMPANY THAT HAS PROVIDED TO YOU A "NOTICE TO OWNER." FLORIDA'S CONSTRUCTION LIEN LAW IS COMPLEX, AND IT IS RECOMMENDED THAT YOU CONSULT AN ATTORNEY. BUYER'S RIGHT TO CANCEL This is a home solicitation sale,and if you do not want the goods or services,you may cancel this contract by providing written notice to the Seller in person,by telegram,or by mail.This notice must indicate that you do not want the goods or services and must be delivered or postmarked before midnight of the third business day after you sign this contract. If you cancel this contract,the seller may not keep all or part of any cash,down payment. Date Buyer signed this contract is: 2/24/2021 _. If Buyer decides to cancel this contract,Buyer will send the cancellation notice to Seller at its address provided below within three business days after this date. i By signing below,Buyer agrees to the terms and conditions stated above and on the reverse side of this page. Buyer(s): If t$oaneouse must sign as well). D1'o--cusi9nea by: By e By FMAAMA83BD495... FMAAMAWBD495... ACCEPTANCE:By signing below,Seller hereby accepts Buyer's offer according to the terns and conditions stated above and on the reverse side. DocuSigned by: US Solar Squared,LLC B 2732 Broadway Center Blvd. Seannate Gs, rest ent Brandon,Florida 33510 20A494735B8B49A.. I State License#CVC57002 Date Accepted 2/26/2021 CHAPTER 658 NOTICE OF CLAIM CHAPTER 558, FLORIDA STATUTES, CONTAINS IMPORTANT REQUIREMENTS YOU MUST FOLLOW BEFORE YOU MAY BRING ANY LEGAL ACTION FOR AN ALLEGED CONSTRUCTION DEFECT. SIXTY DAYS BEFORE YOU BRING ANY LEGAL ACTION, YOU MUST DELIVER TO THE OTHER PARTY TO THIS CONTRACT A WRITTEN NOTICE, REFERRING TO.CHAPTER 558, OF ANY CONSTRUCTION CONDITIONS YOU ALLEGE ARE _ DEFECTIVE.AND PROVIDE SUCH PERSON THE OPPORTUNITY TO INSPECT THE ALLEGED CONSTRUCTION DEFECTS AND TO CONSIDER MAKING AN OFFER TO REPAIR OR PAY FOR THE ALLEGED CONSTRUCTION DEFECTS. YOU ARE NOT OBLIGATED TO ACCEPT ANY OFFER WHICH MAY BE MADE. THERE ARE STRICT DEADLINES AND PROCEDURES UNDER THIS FLORIDA LAW WHICH MUST 'BE MET AND FOLLOWED TO PROTECT YOUR INTERESTS. Installation 11.10 DocuSign Envelope ID:D3(;7562E-FC50-46D0-9276-573FEE8DC381 1.INCORPORATION:The parties agree that the terms and provisions set forth on the front page are incorporated into this contract by reference. 2.JOB SPECIFICATIONS: The specifications for the System are set forth in the work order attached hereto and incorporated herein by reference. The contract price set forth on the front page shall include i) the purchase of the System described in the work order; ii) the installation of the System by Seller or its subcontractor, and iii) costs of supplies and materials used in the installation of the System. Buyer agrees to be fully responsible for all sales taxes,if any,levied in connection with the purchase and installation of the System.Unless otherwise set forth in this contract, the installation shall occur at the address of Buyer stated in the preamble.It is the obligation of the Buyer to provide Seller or its subcontractor utility services so that Seller may properly install the System. 3. SERVICE AGREEMENT:Buyer agrees that this is not a contract governed under Chapter 672,Florida Statutes, as this is a contract primarily for the installation of the System.Seller is not responsible for securing for Buyer any Federal Tax Credit,State or Power Company rebate,if any. 4.RESTOCKING FEE:Except for instances caused by US Solar Squared,LLC,US Solar Squared,LLC will charge the customer a restocking fee of 15%for any cancellations after the recession period ends. 5.FINANCING:If Buyer does not have the funds readily available to pay the contract price following the installation of the System,Buyer agrees to apply to a financing company to pay the contract price on forms provided by the financing company. Such application shall be undertaken by Buyer independent of Seller whom Buyer agrees is neither Buyer's agent nor the agent of the financing company in connection with any loan application.If Buyer applied for financing in connection with this contract, Buyer understands that Seller will not accept Buyer's offer unless the financing is approved by a duly licensed financing institution in good standing in the State of Florida. If Seller accepts Buyer's offer and thereafter learns that the financing has not been issued, or if issued is then withdrawn by the financing company, Seller may terminate this contract without any liability to Buyer. 6.WARRANTY: Seller agrees, on condition that the full contract price has been paid on completion of the installation of the System,to warrant the operation of the System for one year following its installation.If,during this one year period,the System or any its components should fail to operate in accordance with the manufacturer's specifications, Seller agrees to replace or repair the System at its sole cost and expense, including parts, supplies and labor.US Solar provides a 10 year Workmanship Warranty and a 5 year Roof Penetration Warranty. 7.LIMITATIONS OF WARRANTY:The warranty of repair and replacement given by Seller in paragraph 5 above shall be null and void if Buyer or anyone else shall damage or improperly maintain or operate the System, or should injury or damage be caused the System by fire, rain, freeze, storm(including hurricane)or any other force majeure or act of God. Furthermore,Buyer acknowledges and agrees that the proper maintenance and operation of the System is dependent upon the conditions of proper design,construction and maintenance of Buyer's property and building(and pool if applicable)where the System is to be installed and operated,and that the plumbing and electrical services serving Buyer's property are adequate to maintain and operate the System as intended once installed. If the System fails to operate within the manufacturer's specifications because of the failure of any of these conditions, then the warranty of Seller is null and void. Furthermore, it is specifically agreed that SELLER DOES NOT PROVIDE AN IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE AS TO THE SYSTEM BEING INSTALLED. 8. LIMITATION OF LIABILITY:The exclusive obligation and liability of Seller, and that of its officers,subcontractors,agents and employees, to Buyer for any direct, indirect or consequential damages arising from or related to i) the failure of the System to operate according to the manufacturer's specifications, or ii) damage to the property or building of Buyer due to a defect in the System or to the negligent or improper installation of the System, or iii) for any personal injury (including death) caused Buyer by a defect in the System or its improper or negligent installation is limited to the contract price; and,except to that extent,the Buyer hereby releases,discharges and waives any other claim or demand for damages, injuries or losses of any kind or nature, or any other suit or action that Buyer may or does have against Seller, or any of its officers, employees or agents,based upon a defect in the manufacture, installation or operation of the System, including any claim, demand, suit or action Buyer might or could make or bring for the negligent installation of the System by Seller and its officers, subcontractors, agents and employees. Furthermore, neither Seller nor any of its officers, subcontractors, employees or agents, shall be liable for any damage caused to the building or property of the Buyer during the installation of the System unless Buyer serves written notice on Seller of the alleged damages within five (5)days following installation. 9. ARBITRATION: Any dispute arising under or related to this contract, including any tort action arising out of or related to the installation of the System,shall,if not resolved by the parties,be referred to binding arbitration.Only a court of competent jurisdiction shall have the right to determine if the subject matter of the proposed arbitration comes within the terms of this arbitration provision if the parties disagree as to the arbitrability of the matter. Arbitration shall be conducted in the Hillsborough County, Florida in accordance with Commercial Arbitration Rules of the American Arbitration Association then pertaining, and judgment on any award rendered in such arbitration may be entered in any state or federal court. The parties agree to allow the American Arbitration Association to choose the arbitrator, and its decision as to the selected arbitrator shall be binding unless either party can show the chosen arbitrator to be incompetent or biased for or against any party.Notices in connection with such arbitration must be served by personal delivery or certified mail, return receipt requested, on Seller at its address stated on the front page hereto. Costs of arbitration, including the filing costs and related arbitrator fees, shall be awarded as determined by the arbitrator; but only a court having jurisdiction over the parties may make a determination whether attorneys fees are recoverable, and if so, in what amount. Notwithstanding the foregoing,the parties hereto,and those in privity with the parties hereto,agree that any action or suit to foreclose a mechanics lien brought pursuant to Chapter 713,Florida Statutes,shall be exempt from the application of this arbitration agreement. 10. MERGER:This contract,if accepted by Seller,represents the final expression of the representations,terms and covenants of the relationship established between Seller and Buyer and the installation of the System. Buyer agrees that Buyer is not relying upon any other representation or statement made heretofore by any sales agent,independent contractor or representative of Seller to Buyer as an inducement to enter into this contract, and Buyer releases Seller from any other inducement or representation that is not included herein, even if such representation was material to Buyer's decision to enter into this contract. Buyer agrees that only an officer or member of Seller has the authority to bind Seller to this contract,or waive or modify any of its terms.Furthermore,Buyer understands and agrees that no sales agent,independent contractor or employee of Seller has the right to promise Buyer that any rebate of any sort will be made or given with respect to the purchase or installation of the System. 11.GOVERNING LAW,VENUE:This contract is to be construed under and governed by the laws of the State of Florida.Any action, suit or other proceeding between the parties hereto, whether or not such action, suit or proceeding arises tinder this contract, shall be brought in Hillsborough County, Florida;and the parties agree to waive venue in any other county. However, if the suit or action includes a mechanic's lien foreclosure, venue shall be placed in the county where the System was installed. 12. NON-ASSIGNABILITY:Buyer may not assign this contract,nor any of Buyer's rights hereunder,to another. 13. PAYMENT:Buyer agrees to pay the full contract price on completion of the installation of the System,time being of the essence. 14. DEPOSIT:If the work order given in connection with this contract provides for Buyer to give Seller a deposit as a condition of Seller accepting Buyer's offer, Buyer shall have the right to withdraw its offer if the amount of the deposit is not agreeable to Buyer. Payment of the deposit to Seller's employee shall be conclusively-deemed Buyer's agreement to enter into this contract and pay the deposit. Despite accepting such deposit, Seller shall not be obligated to apply for any permit within thirty days of accepting the deposit or commence work within 90 days of the permit(s) being issued,and the parties hereto waive application of Florida Statute§489.126(2)to the extent it applies to this contract,if atall. 15. ACCEPTANCE: If Seller does not provide notice to Buyer that Seller has accepted Buyer's offer within forty days following the date Buyer signs this contract,Buyer's offer to enter into this contract shall expire.However, should Seller proceed to install the System following expiration of the acceptance period with Buyer's knowledge and approval,then the parties hereto shall be bound by the terms of this contract. Installation 11.10 INSTR#2021045954 OR BK 10295 PG 1 294 Page 1 of 1 03/08/2021 10:13 AM Rcpt:2270015 Rec:10.00 DS:0.00 IT:0.00 Nikki Alvarez-Sowles,Esq.,Pasco County Clerk&Comptroller PeanttNa Patae110NclC O�J�`-��� IV�UVdUV-VV(.0 NOTICE OF COMMENCEMENT sated� L comfy or `�I sw- the UNDERSIGNED thereby ghrea arise ttM imp ovememwAl be made to certain real pmpary,and in accordance with Chapter713,Flodde Staudes, mefoflovdnylydotmatlonlsptovtdedfithbNotleedCommegpgnent�� 1. Desolpson d Ptope /w�//Pa�w Iderttldmtlon No.�1l 1� ,r� ) tili r� j 2. General Desatptlon of Improvartiam 3. Owner Infortmaton or lessee h tmiation Nihe Leseee contrasted for the improvement AmA Q l� �� e AddressCRY State mta 100 YestinPropatry: / Name of Fee Simple Titleholder. At dlferenttram Owner hated above) Aar. U S 501� cny �"° 4. ContranireCo ar- 'Sw er,3road�d�l,�l vtdn/ - Aaftew �L cny State C*aadoe3 Telephone No.:l-f50C) ��C� 5. smirf. Name Address Gpr State Amami of Bond:s Telephone No.: a. Lender. Name Addmu CRY State LondWa Toiephro Na: 7. Peroons wuhin the State or Fiords dedprteled by the owner upon wham whoee or other dountenfs may be seared as provided by Serbon 713.13(1)(a)(7),Flalde StetiRes: Name Address City Stale Telephone Weriber d Designated Person: 6. In adddan to hynsetf,the owner des*ateo Of— to moehra a copy of the Uenor s Notice as provided in SeCbn 713.13(1)(b),Florida Stetims. Telephone Number of Person or EMlty Designated by Owner. 9. Expiration date of Notice of Commenoernent(the ertproaon date may not be before the completion of=WrInfion and flnel payment to the contractor,but wflt be one yearhom the date ofreowdaig untm a dmerord data to spe filled): WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 71 PART 1 SECTION 713.13 f10RIDA STATUTES AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE+OF COMMENCEMFslI MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING CONSULT WRHYOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMEa Under ry i art"off and 1eLdetlere that I have road the roregdng notice oJ�mmertoeyert a�dn Rt the i stand Uterein era true to the test STATE OFFLORIDA C COUNTY OF PASCO - dOwner a a Leseee'e admd C9Aoar/DiradalP aneget Siignsta"TrtlelOffice A The fmregdep inttila eat was etlaroWedged batarb mo thlaaday of 2QJ by� n/1 -- s3 1 J QAASt.OLA (type a out", .g.,dew. btni®e,atlaroy in fad)far (nW"ofparty of ono Inetrianerawea Pamon*Known 0 OR Prod r,,Bddd�Identtlrimgon� Notary Signature TypedldedieemtamPtodumd�Jt� Name(Prim) JASON S.MONCHGESANG Notary Public-State of Florida ='• •= Commission ti GO 959054 rr a+ My Commission Expires February 17.2024 7.68kW SOLAR ARRAY PLANS PROJECT DESCRIPTION; �� FOR 24 MODULES - MISSION SOLAR: MSE320SR8T GENERAL NOTES 24 INVERTERS - ENPHASE: IQ7-60-2-US 1. THIS IS TO CERTIFY THAT TO THE BEST OF AMY P ETR E MY KNOWLEDGE AND BELIEF, THESE PLANS CONFORM WITH FLORIDA BUILDING CODE 2020 �i� •JJ�` GOVERNING CODES: WITH ALL SUPPLEMENTS AND ADDITIONS. 0 WHEAT STO E D R 2020 FLORIDA PLUMBING CODE, 7TH EDITION 2. ALL PRODUCTS TO BE INSTALLED PER 810 2020 FLORIDA BUILDING CODE, 7TH EDITION MANUFACTURER'S WRITTEN SPECIFICATIONS. 2020 FLORIDA MECHANICAL CODE, 7TH EDITION I, ANDREW D. HALL PE# 87479 AN ENGINEER ZEPHYR H I LLS, FLO R DA 33540 NFPA 1 2018 NEC 2017 LICENSED PURSUANT TO CHAPTER 471, CERTIFY THAT THE PV ELECTRICAL SYSTEM AND ELECTRICAL COMPONENTS ARE DESIGNED AND APPROVED USING THE STANDARDS CONTAINED IN THE MOST RECENT VERSION OF THE FBC, FBC DRIVEWAY 107. EAVE Wind Design Data Wind Speed 140 mph Risk Category II Exposure C Gust Factor ±0.18 "A"Dimension 5.1 ft Roof Pressure for Components and Cladding Zone 1 16.47 psf -25.65 psf Zone 2 16.47 psf -44.55 psf Zone 3 16.47 psf -66.15 psf DISCONNECT MW. 4' CLEARANCE PER NEC 110.26(A) ffi _ iJ . . . . . . ta TYP. RIDGE OBSTRUCTION MISSION SOLAR: MSE320SR8T(TYP) DRAWING INDEX: 3' MIN.TYP S-1 COVER S-2 ARRAY LAYOUT & DETAILS S-3 ELECTRICAL S-4 NOTES S-5 SPECIFICATIONS S-6 SPECIFICATIONS T1P. EAVE MODULE ROO L. S-7 SPECIFICATIONS N� S-8 SPECIFICATIONS N�k dy PV MODULE QMR-UMC ��r CLIP QMR 3/8"-16 X 3/4" HEM( HEAD BOLT O> CROSSRAIL LIGHT 3/8" - 16 FLANGE NUT (TYP) SUNMODO NANO SUNMODO NANO RAFTER MOUNT QMR RAFTER MOUNT CROSSRAIL LIGHT (lP) TOP VIEW EXISTING UNDERLAYMENT NTS EXISTING ROOF TRUSS V1/2" PLYWOOD 5/16" DIA SS LAG SCREW 2-1/2" EMBED MIN. TYPICAL SHINGLE ROOF ATTACHMENT NTS SUNMODO NANO RAFTER MOUNT 48" MAX. O.C. QMR-UMC CLIP (�P) (nP) QMR-UEC CLIP Ti (TYP) w c„ QMR-UEC MISSION SOLAR: MISSION SOLAR: < E MSE320SR8T QMR-UMC CLIP MSE320SR8T � o U H (nP) TYP (TYP) (TYP) ¢ LJ ( ) W QMR-UMC CLIP QMR-RL14 (TYP) QMR-UEC CLIP SUNMODO NANO RAFTER MOUNT (TYP) TYPICAL LAYOUT (lP) (TYP) NTS 6s ® �c #10 THWN-2 (3 CONDUCTOR) NOTE: 3/4" EMT, FMC, FOR EXTERIOR ALL INVERTERS ARE EQUIPPED APPLICATION USE PVC OR #10 THWN-2 (3 CONDUCTOR) W/ INTERNAL RAPID SHUTDOWN LFMC/LFNMC CONDUIT SYSTEM PER NEC 690.12 3/4" EMT, FMC, FOR EXTERIOR LOCKABLE FUSED APPLCATION USE PVC OR PV AC DISCONNECT LFMC/LFNMC CONDUIT ENPHASE Q CABLE MISSION SOLAR: MSE320SR8T 30A 240V 2-POLE #10 THWN-2 (3 CONDUCTOR) ENPHASE Q CABLE Q-12-10-240 W/ ENPHASE 107-60-2-US .30A RK-1 FUSE 3/4" EMT, FMC, FOR EXTERIOR Q-12-10-240 (TYP) INVERTER APPLCATION USE PVC (TYP) OR LFMC CONDUIT N L2 L1 METER I - ____ DC AC DC AC L1 L1 L2 L2 NO. 1 NO. 12 N N SPACE I 20 2a QMR—RL14 (TYP) SPACE 20 20 G N0. 1 N0. 12 ALL/NOTSTRINGSTO HAVE #6 THWN-2 G AC AC II II TERMINATORS & SEALING CAPS DC DC INSTALLED PER MANUFACTURER'S 30 7KBBINER BOX SPECIFICATIONS NEUTRAL GROUND USEDSIDENTIALX ENPHASE Q CABLE MISSION SOLAR: MSE320SR8T BOND AT Q-12-10-240 W/ ENPHASE IQ7-60-2-US ENPHAii _________________ SE IQ COMBINER PLG SYSTEM (TYP) INVERTER W/ (2) 20 AMP BREAKER (SEE NOTE #2) NEUTRAL GROUND AC PANEL 150 AMP/240V No NOTES: ' �o•.,� 1. ALL ASPECTS OF THE ELECTRICAL WORK REQUIRED TO COMPLETE THE PROJECT REPRESENTED IN THIS DOCUMENT ����'•rD1 MODULE SPECIFICATION INVERTER SPECIFICATION SHALL COMPLY WITH THE MANUFACTURERS RECOMMENDATIONS/SPECIFICATIONS AND ALL CODES, STATUES AND STANDARDS ADOPTED BY THE STATE AND THE LOCAL AUTHORITY HAVING JURISDICTION. MODULE MAKE MISSION SOLAR INVERTER MAKE ENPHASE 2. ALL COMPONENTS MUST BE GROUNDED PER NEC 690.43. MODULE MODEL MSE320SR8T INVERTER MODEL IQ7-60-2-US 3. ALL EQUIPMENT SHALL BE LISTED PER NEC 690.4(0). FSEC CERTIFICATION MAX AC POWER OUTPUT 250 VA 4. THE INFORMATION PROVIDED IN THESE DOCUMENTS IS NOT EXHAUSTIVE. IT REMAINS THE CONTRACTORS PMAX (STC) 320 W MAX. INPUT VOLTAGE 48 V RESPONSIBILITY TO ACHIEVE THE PROPOSED INSTALLATION, IN FULL EXERCISE OF AND COMPLIANCE WITH THE VOC (STC) 40.80 V NOM. DC VOLTAGE @ 240V 240 V ITEMS IDENTIFIED IN NOTE 1. VMPP (STC) 34.22 V NOM. AC VOLTAGE 16-48 V 5. PER NEC 690.17 PROVIDE A WARNING SIGN AT ALL LOCATIONS WHERE TERMINALS OF THE DISCONNECTING NTINUOUS OUTPUT CURRENT 1.00 A MEANS BE ENERGIZED IN THE OPEN POSITIONS. SIGN SHALL READ "WARNING-ELECTRIC SHOCK HAZARD - DO MAX.. ISC (STC) 10.03 ANOT TOUCH TERMINALS - TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN IMPP (STC) 9.35 A MAX. DC CURRENT 15.0 A POSITION OR EQUIVALENT. NOCT 46 C MAX. DC POWER (STC) 350 W 6. PER NEC 705.10, PROVIDE A PERMANENT PLAQUE OR DIRECTORY SHOWING ALL ELECTRIC POWER SOURCES ON TC ISC 0.039 %/C CEC EFFICIENCY 97 % THE PREMISES AT SERVICE ENTRANCE. TC VOC -0.280 %/C 7. INTERCONNECTION METHOD SHALL COMPLY WITH NEC 705.12. TC PMPP -0.377 %/C 8. PV METER MAY OR MAY NOT BE REQUIRED BY THE AHJ AND/OR UTILITY FOR INTERCONNECTION. 9. CONDUCTOR SIZING OF THIS DESIGN IS BASED ON RACEWAYS LOCATED OUTSIDE ATTICS OR NOT EXPOSED OPERATING TEMP. -40-+85 C TO DIRECT SUNLIGHT. WHERE TWO DIFFERENT AMPACITIES APPLY TO ADJACENT PORTIONS OF A CIRCUIT, THE HIGHER AMPACITY SHALL BE PERMITTED TO BE USED BEYOND THE POINT OF TRANSITION, A DISTANCE EQUAL TO 3.OM (10ft) OR 10 PERCENT OF THE CIRCUIT LENGTH FIGURED AT THE HIGHER AMPACITY, WHICH EVER IS LESS. NEC 310.15 (B)(2) SAFETY LABELS AND MARKINGS GENERAL NOTES: N A N EM ER CE N CY Co NTACT 10.ALL CONDUCTORS AND RACEWAYS SHALL BE SUPPORTED ON INTERVALS AND BY METHODS REQUIRED BY THE NEC. 1 EQUIPMENT APPLIED LABELS FOUND HEREIN SH B SUCH INVERTERS SOLAR ALL MODULES APPLIED TO SUCH U S SOLAR 12.PV ARRAY INTERCONNECTION TO BE MADE WITH BACK-FEED BREAKER. PRE 13.GFI BUILT IN TO ALL INVERTERS.EQUIPMENT 2. LABELS FOR INFORMATIONAL ANDMARKINGSSHAL BE APPLIED TO COMPONENTS IN 1 -813-434-0284 ACCORDANCE WITH THE CURRENTLY ADOPTED EDITION OF NEC. 3. ALL REQUIRED PRODUCT SAFETY AND WARNING SIGNAGE SHALL BE UV RESISTANT OUTDOOR-RATED LAMINATED VINYL IN ACCORDANCE WITH ANSI Z535.4-2011. SAFETY LABELS AND MARKINGS LEGEND S A E ETY LA LOCATION OF SERVICE DISCONNECTING MEANS. APPLY TO MAIN SERVICE DISCONNECTING MEANS AND PV DISCONNECTING MEANS AT POCC. SOLAR PHOTOVOLTAIC SYSTEM MAIN SERVICE DISCONNECT MARKING Ai -WARNING- A LABEL SHALL BE PERMANENTLY AFFIXED TO THE MAIN SERVICE -WARNING- ELECTRIC SHOCK HAZARD. THE DC AUTHORIZED PERSONNEL ONLY CONDUCTORS OF THIS PHOTOVOLTAIC DISCONNECT PANEL SERVING ALTERNATING CURRENT (AC) AND DIRECT SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED CURRENT (DC) PHOTOVOLTAIC SYSTEMS. THE LABEL SHALL BE RED WITH RATED AC CURRENT: 30A AUTHORIZED PERSONNEL ONLY WHITE CAPITAL LETTERS AT LEAST 3/4 IN. IN HEIGHT AND IN A NOMINAL AC VOLTAGE: 240V LOCATION: DISCONNECTS, INVERTERS, NONSERIF FONT, TO READ: "WARNING: PHOTOVOLTAIC POWER SOURCE." LOCA11ON: MAIN PV PANEL JUNCTION BOXES, OTHER ENCLOSES HOLDING DC CONDUCTORS THE MATERIALS USED FOR THE LABEL SHALL BE REFLECTIVE, WEATHER RESISTANT, AND SUITABLE FOR THE ENVIRONMENT. CIRCUIT DISCONNECTING MEANS MARKING PHOTOVOLTAIC DISCONNECT SOLAR PV SYSTEM EQUIPPED A PERMANENT LABEL SHALL BE AFFIXED ADJACENT TO THE CIRCUIT WITH RAPID SHUTDOWN BREAKER CONTROLLING THE INVERTER OR OTHER PHOTOVOLTAIC SYSTEM TURN RAPID ELECTRICAL CONTROLLER SERVING AC AND DC PHOTOVOLTAIC SYSTEMS. —WARNING— SHUTDOWN SWITCH TO 'OFF" w ryas THE LABEL SHALL HAVE CONTRASTING COLOR WITH CAPITAL L ELECTRI ETTERS AT C SHOCK HAZARD THE POSiON TO SHUT DOWN PV LEAST 3/8 IN. HEIGHT AND IN A NONSERIF FONT, TO READ: DO NOT TOUCH TERMINALS. TERMINALS ON SYSTEM AND REDUCE / BOTH THE LINE AND LOAD SIDES MAY BE SHOCK HAZARD IN "PHOTOVOLTAIC DISCONNECT." THE LABEL SHALL BE CONSTRUCTED OF ENERGIZED IN THE OPEN POSITION, THE ARRAY DURABLE ADHESIVE MATERIAL OR OTHER APPROVED MATERIAL. LOCATION; AC DISCONNECT(S) S A PERC 6O LA,,'S LEADING 315-325W Enphase IQ 7 and IQ 7+ Microinverters lY Electrical Parameters at Standard Test Conditions(STC) INPUT DATA(DC) IQ7-60-2-US IQ7PLUS-72-2-US _______Y Module Type MSF3Y55R8T MSES2OSR8T MSE32SSRST IEC Commonly used module pairings 235W-350W+ 235W 440 W+ Power Output Pmax Wp 315 320 325 61215-61730-61701-Salt mist Module compatibility 60-cell PV modules only 60-cell and 72-cell PV modules Module E(ftcieney If. 1 B.U5 18 94 19.24 Ma-0n)Um lllp,st DC volLaye UL Peak power tracking voltage 27V-37V 27V-45V Tolerance 0'+3°Jo 0"+3°1 0"+3% UL 1703 listed Operating range 1&V-48V 16 V-60 V Short-Circuit Current lec A 0997 10.028 10060 Min/Max start volts e 22V/48V 22 V 160 V Open Circuit Voltage Voc V 40.44 40.80 41.14 C®et CEC MaxDCohartcircuitcurrerlt(modtllels) ISA 15A Rated Current Imp p 3.253 9.351 9.387 tares Overvoltage class DC port II II Rated Voltage Vmp V 34.04 34.22 34.62 DC pert mfeed r•urrent 0 A 0 A Fuse Rating 2t0 2d 2C PV array configuration AC side protection requires max 20Aipe branch DC side protection required; circuit OUTPUT DATA(AC) IQ 7 Microinverter IQ 7+Microinverter Peak output power 25!r VA 2ra5 VA M5E32DS128T:32OVdP,80 CELL SOLAR MODULE Maximum continuous output power 240 VA 290 VA Normal Opexatlt tall Temperature{NOVT) 48.09°C(±2°C) CURRENT-VOLTAGE CURVE Itorrlt+aal(t L)voltage/ranger 740 V f 208'V f 240 V/ 208V/ • 211-264 V 183-229V 211-264 V 183-229 V Temperature Coefficient of Pmax -0.377%!°C 12 Maximum continuous output current 1.0 A 1,15 A 1,21 A 1.39 A Temperature Coefficient of Voc -0280%1°C seat Temp.-25 C: Nofiinai frequency 60 Hz 60 Ha ...Incident....lard.--1o0OW/m...... Temperature Coefficient of Ise 0.039°k/°C m z ""' "' Extended frequency range 47-68 Hz 47-68 Hz AC short circuit fault current over 3 c yeses 5,8 Amts 58 Arms g ,._.. ..incident _..rrrd...80O....W/mx....... .....,:... ......_....... P l ) a ( ) ( ) s, N a w Maximum units er 20 A L-L branch circuit 16 240 VAC 13 240 VAC w ardent 13(208 VAC) 11(208 VAC) ...er .lrrd_.649 W/rtt.....,._ 2 Maximum System Voltage 1,OOtIVdC ' , Overvoltage class AC port tit Ill Operating Temperature Range -40°C(-40°F)to+85°C(185°F) a - Incident Irrd 40o yr/mz AC par:backfeed current 0 A 0 A 1 Fowerfactor setting 1.0 1.C MaxlmumSeriesFuseRatIng 20A incident Irrd.=2W W/m2 �l z 1 ..._.,,.,_ Powerfactor(attirig(adjustable) 0.7 leading...0.71agging 0.7 leading...0.7lagging Fire Safety Classification Type 1,Class C �� ' EFFICIENCY @240 V @208 V @240 V @208 V Front&Baok Load(iiI.standard) 5$39 Pa(117 psi) o Peak CEC efficiwicy 9776`R 97.6 4 575% 0735 Tested to UL4703 standard ° .. x e CEC weighted efficiency 97.0% 9/.0% 97.0% 97,0% Hall Safety Impact Velocity 25mm at 23 mils Voltage(V) MECHANICAL DATA IQ 7 Microinverter Current-voltage characteristics with dependence on irradiance Amfilant terrrperature range __._—. 4+3°C to*65'0 s, and module temperature Relative humidity range 4°b to 100%(condensing) Solar Celts P-type mono-crystalline silicon (168.75nma) Connector tysc' MC4(or Amphenoi H4 CTX w:th additional Q-DCC-5 adaptor) Cell Orientation tirl cells(6x10),5 busbar BASIC DESIGN(UNITS:rata) Dimensions(WxHxD) 212 mm x 175 mm x 30.2 mm(without bracke₹) 676mm x 1008mm x 40mm a°a . Cooling 7.08 (2 38 @hs) Module Dimenlston (66.98 in,x 39,68 irt.x 1.88 in Cooling Natural convection-No fans Weight 20 kg(441b) Approved for wet locations Yes 35 as Pollution degree PD3 3.2mm;(Q 1`26in.)tempered; �KatttQlass �� " e-.nci0sure Class it double insulated,corrosion resistant polymer+¢ensure krw-htut,aret-reflective coatrt J v° Environmental category/UV exposure rating NEMA Type 6/outdoor Frame Anodized aluminum alloy a3 f FEATURES Encaprautant Eth$ete vinyl acetate(EVA) Oomrnunieetion Power Line Conlrminicatloft(PLC) J-Box Protection class IP67 with 3 bypass-diodes 11111111111 If Iii I Ifi III If 11111 Monitoring Enlighten Manager and MyEnlighten monitoring options. s Both options require installation of an Enphase IQ Envoy. Cables PV wire.4m(3837 inm),4murta 1 12 AW>3 IlllllllIllIlIllLlIl1ll1ll 11801111R, D:s nneet,rx means The AC and DC connectors have been evaluated srici approved by-1i-for t,sr as the load-break Connector MC4 Compatible disconnectrequiredbyNECti0O- Fl If III II FIFI IliflilIllil 11111 se Compliance CA Rule 21(UL 1741-SA) t UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B,ICES-0003 Class B, a i I CAN/CSA-C22.2 NO.107.1-01 This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and container FT Palters Petrels 31 W NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems,for AC °0B and DC conductors,when installed according manufacturer's instructions, 53' Double stack 36 936 299.52 kW Front View Back View 1.No enlorred DC/AC ratio.See the compatibility caicuiator at P Y h1tRELLellphase,&attlllmL.us/.suRp4ztia1RS1s11ec4.mR8fibiity. •k7 Doubts stack 28 728 232 96 kW 2.Nominal voltage range can be extended beyond nominal if required by the utility. 3.Lint?s may vary.Refer to local requirements to definethe number of microinverters per branch in your area. Panels Weight Height Width Length Pallet >� To learn more about Enphase offerings,visit enphase.com EN PHASE 26 9,4981hs 42.45^ 45.50" 67.00° �--- P 9 P MISSION SOLAR -" c.2018 Enchase Ermrgy.Ail nigh<is resc.ved.Aii trademarks on brands used are the property of Enphase Er>nrgy,Inc ENERGY ' 2uit3-0?:',a Mission Solar Energy reserves the right to make specification changes without notice Mission Solar Energy 18803 S.New erauntels Ave.,San Antonio,Texas 78235 C.JCUMz.?:;r;L.t'12R.(.iT.3CC•3 R iISO:JY:N2 ftL`ii:ipN t��Te:.`-:23:'r2C 1nt Ofgm13510n50iar.COm I WWW.mIS510flS018 r.COm N: Enphase Q Cable Accessories Enphase IQ Combiner 3 MODEL NUMBER Q AGGREGATOR SPECIFICATIONS iQCombiner3 to Combiner 3 with Eniphase IQ Envoly"printed circuit board orintegratedrevenuegradePV X-IQ-AM1-240.3 prodstctien metering(ANSI C12.2O+1-0.5%)and optinnaI 000suiriplion mon ring(e/25%). Q Aggr etor C 8A-3 1 P40(single phase)Crrriitsirtec up to three micro inverterbrstsct e&.Into erne haute run. ACCESSORIES and REPLACEMENT PARTS(not included,order separately) Ar�tecz with maximum Ott.A,2-pole OCPO. _ .,_ „- ..,._.._.,.,....,- ...,..,...4,_..,...- Q Commercial Aggregator 0-BA -SP-35(three•phase).Combines up to three,single-phase microinverter branches into a three- nphaie Monrlye t nnnect" phase horn run.Protect with maximum 40 A,3-pole OCPD, CF_LLMODEM O'1(4Gr11 year data plan) Plug and play inducts al grade cellular modern with data plan for systems up to 60 CGLLMODEM-Ot(3G15-year data plsn) micromverters.(Available in the US,Canada,Mexico,Puerto Rico,and the US Virgin Islands, O'mensrons 1°O mm(W)x 227 mm(0)x 80 rnm(H)(7.5 in(qtr)x 9 in(C)it'2 in(H)) GELL 40DEM-Ml(40 based LTE-M/5-year data plan) where there is adequate cellular service in the in'steliatlort area.) Homerun conductor size range z17:o ti Consumption Monitoring*CT Split core current transformers enable whole home consumption metering(+j-2.5%). CT 200-SPLIT Enclosure rating NEMAS(up to 45'from horizontal) *Consumnton monitoring is retuired`or Enphase Storage Systems Temperature range 40 C to eSS'C(-d0 F Io+122'F) Wireless USB adapter Installed at the IQ Ettvoy.Fo'communications with Enphase Encharge'storage and Enphase COMMS-KIT-D1 Enpower"smart switch includes USB cable for connection to 1O Envoy or Enphase IQ Combiner' Compliance UL1741(assembled product)and Ui..6-103(btulkhead cent",tors) and allows redundant wireless communication with Fnoharg+?and Enpnwer Circuit Breakers Supports Eaton BR210,BR215,BR220,BR230,BR240,BR250,and BR260 circuit breakers. CONDUCTOR SPECIFICATIONS BRK-10A-2-240 Circuit breaker,2 pole,10A,Eaton BR210 CC,erdifioation UL3003(raw cable),UL 9763(cable assembllee,DG cable BRK-15A-2-240 Circuit breaker,2 pole.,15A,Eaton BR215 BRK 20A-2P-240 Circuit breaker,2 pole,20A,Eaton BR220 Flame test rating FT4 EFLC^U I Power line carrier(communication bridge pair),quantity cue p&ir Compliance FWHS•Ott,RES I,CE,UV reasistsn r.combined UL for Site United Sic as XA-PLUG-120 3 Accessory receptacle for Power Line Carrier in IQ Combiner 3(required for EPLC-01) Conductortype THHNITHWN-2 dry/wet XA-ENV-PCB.A-3 Replacement JO Envoy printed circuit board(PCB)for Combiner 3 ,..sconnect ng mear:s The AC and AC tardhead connectors have been eve-used and approved by UL for use as thu load-break disconnect iequlred by NEC.690. ELECTRICAL SPECIFICATIONS Q CABLE TYPES/ORDERING OPTIONS Rating Continuous duty Model Number Max Nominal Voltage Connector Spacing PV Module Orientation Connector Count per Box System voltage 120/240 VAC,60 Hz Q t2-10-240 27.7 VAC 1.3 m i4.2 ft) Portrait 240 Eaton BR series busbar rating 125 A Q-1217-240 277 VAC 2.0 m(6.5 ft) Landscape(60-cell) 240 Max.continuous current rating(output to grid) 65 A. 0-12-20-200 277 VAC 2 3 in(7:5 ff) Landscape(72-cell) 200 Max,fuse/circuit rating(output) 90 A ENPHASE Q CABLE ACCESSORIES Branch circuits(solar and/or storage) Up₹o four 2-pole Eaton BR series Distributed Generation(DG)breakers only(not included) Name Model Number Description Max.continuous current rating(input from PV) 64 A `-A r, Rawa Cable Q-12-RAW-200 300 meters of 12 AWG cable with no cCnneeiors Max.total branch circuit breaker rating(input) 80A of distributed generation/90A with IQ Envoy breaker included Field-wireable connector(male) Q-CONN-1OM Make connections from any Q Aggregator open connector Production Metering CT 200 A said core pre-installed and wired to IQ Envoy Field-wireabieconnector(female) Q-CONN-1DF Make connections from any 0 Cable Open COME Lt)F MECHANICAL DATA Cable Clip Q-CLIP-100 Used to fasten cabling to the racking or to secure looped cabling Dina-nsin as(L"lxkfxG) 44 5 8 x ib. cm(19 5°x 14.7x"x 6.63).Height is 21.06 r53. r ii w ntonmitng braCTrets. Gisronnec1 tool Q DISC-i0 Disconnecttool for QCable connectors,DC connectors,and AC module mount Weight 7.5 kg(16.5 Ibs) Q Aggregator sealing caps(male) Q-BA-CAP-10 Sealing cap for unused aggregator connections Ambient temperature range •40°C to 4.444°r;(-40°to 115°F) O Cable sealing caps(female) O-SEAL-10 One needed to cover each unused conttet:tor on the cabling Cooling Natural convection,plus heat shield Terminator Q-TERM-10 Terminator cap for unused cable ends Enclosurvervironinemelratln5 Outdoor,NRTLcertified,NElAlype3R,polycarbcnatecoustructron Replacement DCAdaptor(MC.i) Q-OCC-2 DC adaptor toMC4(maxvoltage100VPC) Wire sizes • 20 Ate 50Abreakerinputs: 14to 4 AWG copper conductors 60 A breaker branch input.-4to 1/0 AWG copper conductors Replacement DC.Adaptor(UTX) Q-DCC-5 DC adaptor to UTX(max voltage 100 VDC) Main lug combined output: 10 to 2/0 AWG copper conductors Neutral and ground; 14tol/0 copper conductors Always follow local code requirements for conductor sizing. TERMINATOR SEALING CAPS Atntede To 21300 meters(6,S6O feet) Terminator cap for unused cable Sealing caps for unused aggregator INTERNET CONNECTION OPTIONS sol d sold in packs often and cable connections -•-- —µ ----- - ---- ------•------- —�-°�--�-^d- --�— (Q-TERM-10) (Q-BA-CAP-1 O and Q-SEAL-10) Integrated Wi-hi 80 ,1 lb/gin Ethernet Optional,802.3,Cat5E(or Cat 6)UTP Ethernet cable (not included) DISCONNECT TOOL CABLE CLIP Ce'lular Optional,CELLMf3DFM-Ot(3G)or CFLLMODSM-03(4S)or CELT MODEM-Mb(4G based U TE-4 friar included l Plan to use at least one per Used to fasten cabling to the racking COMPLIANCE installation,sold in packs of ten or to secure looped cabling,sold in Comffiinr c , ombinr;r Ut-1341,CAN(CSA 022.2 No 147,1,47 CF fi Part 75,Class t3,ICES.03 (Q-DISC-10) packs of ten(Q-CLIP-100) Production metering'ANSI C12.2 accuracy class 0:5(PV production) Compliance,IQ Envoy UL 60601-1fCANCSA 22.2 No.61010-1 To learn more about Enphase offerings,visit enphase.com To learn more about Enphase offerings,visit enphase.com :r)2014 ra':phase testy.Al riOs-resaned.Enph3se,rt,•e Errpi:ase logo;10 Combiner 3,and other trademarks or service nsrnes ar the u 2018 Enphane Enwgy.Al:rights reserved.Ail trademarks or baste used c a Ise property of Enphase tusvrgy.Inc. EN P H AS E. tredcnl3"�s cf Enpbose ESC ,h;c. ENPHASE. 2018ut-02 e *; No = '• ST - . SUNMGAv6,FhZ3':zr - 5 levels of protection against Aesthetically pleasing • • unibody aluminum cast water penetration SOLAR'S • construction 360-degree positioning, serrated surface on both sides for rail mounting ATTACHMENT • • • Versatile mounting option includes direct-to-decking for fast installation • • •. • Integrated Ultra Soft Weather Resistant silicone gasket Alignment markers ,� �, - _ The NanoMount Advantage enable easy installation o - a • " ' " ,/ The fastest roof attachment in • • " solar J Versatile mounting options • ` " a '" " ' including direct-to-decking o a . a - . � . • a a - - a w ' Eliminates the need to lift shingles and prevents damage to Application Composite shingle and rolled asphalt shingle Material High grade aluminum, 304 stainless steel hardware / High Velocity Hurricane Zone Finish Black powder coating w a a - m o - s - Approved - Passed TAS 100 (a) Roof Attachment Rafter and decking _ - . a a a _ Wind-Driven Rain Test Structural integrity IBC and IRC Compliant • ° a a ,/ All materials are compatible with p Warranty 25 years - roof shingles SunModo, Corp. Vancouver, WA., USA •www.sunmodo.com • 360.844.0048 • info@sunmodo.com ' o ✓�7s7'PL'� Structural Quick Mount ingenuity in Engineefing Rail Spans for Quick Mount PV QRail Light System Mean Roof Height: 0<h≤15 ft Panel Orientation: Portrait Table 3 Roof Angle: 7<0 ≤27 degrees Exposure Category: C Roof Ground Wind Speed(mph) Wind Snow Zone Load 100 110 115 120 130 140 150 15'0 170 175 180 190 0 81 81 81 81 81 76 71 66 62 60 59 55 10 76 75 74 73 71 69 67 I 66 62 60 59 55 20 61 61 61 61 60 59 58 56 55 55 54 53 30 52 52 52 52 52 52 51 50 50 49 49 48 Zone 40 45 45 45 45 45 45 45 45 45 45 45 44 1 50 41 41 41 41 41 41 41 41 41 41 41 41 60 38 38 38 38 38 38 38 38 38 38 38 38 70 35 35 35 35 35 35 35 35 35 35 35 35 80 33 33 33 33 33 33 33 33 33 33 33 33 90 31 31 31 31 31 31 31 31 31 31 31 31 0 78 70 67 64 59 55 51 48 45 43 42 40 10 76 70 67 64 59 55 51 48 45 43 42 40 20 61 61 61 61 59 55 51 48 45 43 42 40 30 52 52 52 52 52 52 51 48 45 43 42 40 Zone 40 45 45 45 45 45 45 45 45 45 43 42 40 2 50 41 41 41 41 41 41 41 41 41 41 41 40 60 38 38 38 38 38 38 38 38 38 38 38 38 70 35 35 35 35 35 35 35 35 35 35 35 35 80 33 33 33 33 33 33 33 33 33 33 33 33 90 E62J 31 31 31 31 31 31 31 31 31 31 31 0 556 54 52 48 44 41 38 36 35 34 32 10 56 54 52 48 44 41 38 36 35 34 32 20 61 56 54 52 48 44 41 38 36 35 34 32 30 52 52 52 52 48 44 41 38 36 35 34 32 Zone 40 45 45 45 45 45 44 41 38 36 35 34 32 3 50 41 41 41 41 41 41 41 38 36 35 34 32 60 38 38 38 38 38 38 38 38 36 35 34 32 70 35 35 35 35 35 35 35 35 35 35 34 32 80 33 33 33 33 33 33 33 33 33 33 33 32 90 31 31 31 31 31 31 31 31 31 31 31 31 Notes: 1. Tables are based on critical rail span for load combinations as specified in chapter 2 of the ASCE 7-10 and allowable design loads per the 2015 Aluminum Design Manual. 2. Panels are assumed to be in portrait orientation with a maximum length of 67.5" 959 Larchmont Court,Aurora,IL 60504 3/4/2019 630-219-1997(P) www.structuralenginuityinc.com C3