Loading...
HomeMy WebLinkAbout21-1695 sL m Q r.inyir�ea City Of Zephyrhilis PERMIT NUMBER 5335 Eighth Street Zephyrhills, FL 33542 BAR-001695-2021 Phone: (813)780-0020 Fax: (813)780-0021 Issue Date: 04/07/2021 4 Permit Type: Add/Alter (Residential); Property Number Street Address 02.26 210230 00000 0230 6932 Oakcrest Way Owner Information Permit Information Contractor Information Name: JOHN REEL Permit Type:Add/Alter(Residential) Contractor: LIPTON WINDOW& DOOR Class of Work:Add/Alter Residential Address: 6932 Oakcrest Way Building Valuation:$7,936.00 ZEPHYRHILLS,FL 33542 Electrical Valuation:$0.00 Phone: (813)326-2539 Mechanical Valuation:$0.00 Plumbing Valuation:$0.00 Total Valuation:$7,936.00 Total Fees:$119.52 Amount Paid:$119.52 Date Paid:4/7/2021 8:23:34AM Project Description, REPLACE WINDOW&3 DOORS Application Fees Building Permit Fee $79.68 Building Plan Review Fee $39.84 REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c).the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each subsequent reinspection. Notice: In addition to the requirements of this permit,.there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permit required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner:Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications add fee Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. 141QL,1* CONTRACTOR SIGNATURE PE IT OFFICE PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER a' 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department Date Received Phone Contact for Permitting 813 06-9895_ )99122 99 991 morel Owner's Name John Reel Owner Phone Number 813-326-2539 owners Address 16932 Oakcrest Way Owner Phone Number Fee Simple Titleholder Name Owner Phone Number Fee Simple Titleholder Address JOB ADDRESS 6932 Oakcrest Way LOT# 23 SUBDIVISION Oak Crest Estates PARCEL ID# 02-26-21-0230-00000-0230 (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED NEW CONSTR ADD/ALT = SIGN = = DEMOLISH B INSTALL B REPAIR PROPOSED USE = SFR 0 COMM = OTHER TYPE OF CONSTRUCTION = BLOCK 0 FRAME = STEEL = DESCRIPTION OF WORK Replace size for size 1 Window,3 Doors BUILDING SIZE SO FOOTAGE HEIGHT ®BUILDING $7936 VALUATION OF TOTAL CONSTRUCTION =ELECTRICAL $ AMP SERVICE = PROGRESS ENERGY = W.R.E.C. 1 =PLUMBING $ / =MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION =GAS = ROOFING = SPECIALTY = OTHER FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES NO t5)J J BUILDER COMPANY Lipton Window and Door 1 SIGNATURE f� � REGISTERED Y/N FEE CURREN Address 17335 Gunlock Rd Lutz FL 33558 License# CBC1258461 ELECTRICIAN COMPANY SIGNATURE REGISTERED I Y/N FEE CURREN I Y/N Address I License# PLUMBER COMPANY SIGNATURE REGISTERED Y/N FEE CURREN Y/N Address I License# MECHANICAL COMPANY SIGNATURE REGISTERED Y/N I FEE CURREN Y/N Address I License# OTHER COMPANY SIGNATURE REGISTERED Y/N FEE CURREN Y/N Address License# 3.■[[.[1 CCi[_i.[[.[[.l.i i,r[.!!.["1.[".[_i•C!I[[![1!.[..[I_[[.CCi--[_([>t.!_[-[.[.!9.11.1.1 RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-OW Permit for new construction, Minimum ten(10)working days after submittal date.Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster,Site Work Permit for subdivision0arge projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction. Minimum ten(10)working days after submittal date.Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet Compliance SIGN PERMIT Attach(2)sets of Engineered Plans. —PROPERTY SURVEY required for all NEW construction. Directions: Fill out application completely. Owner&Contractor sign back of application,notarized If over$2500,a Notice of Commencement is required.(A/C upgrades over$7500) •• Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage) Driveways-Not over Counter if on public roadways..needs ROW , 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department NOTICE OF DEED RESTRICTIONS:The undersigned understands that this permit may be subject to"deed'restrictions"which may be more restrictive than County regulations.The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES:If the owner has hired a contractor or contractors to undertake work,they may be required to be licensed in accordance with state and local regulations.If the contractor is not licensed as required by law,both the owner and contractor may be cited for a misdemeanor violation under state law.If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work,they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847-8009. Furthermore,If the owner has hired a contractor or contractors,he is advised to have the contractor(s)sign portions of the"contractor Block"of this application for which they will be responsible.If you,as the owner sign as the contractor,that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES:The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings,change of use in existing buildings,or expansion of existing buildings,as specified In Pasco County Ordinance number 89-07 and 90-07,as amended.The undersigned also understands,that such fees,as may be due,will be identified at the time of permitting.It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a"certificate of occupancy"or final power release.If the project does not involve a certificate of occupancy or final power release,the fees must be paid prior to permit Issuance.Furthermore,if Pasco County Water/Sewer Impact fees are due,they must be paid prior to permit issuance In accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713,Florida Statutes,as amended):If valuation of work Is$2,500.00 or more,I certify that I,the applicant, have been provided with a copy of the"Florida Construction Lien Law—Homeowner's Protection Guide'prepared by the Florida Department of Agriculture and Consumer Affairs.If the applicant is someone other than the"owner",I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner'prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT:I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction,zoning and land development.Application is hereby made to obtain a permit to do work and installation as Indicated.I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction,County and City codes,zoning regulations,and land development regulations in the jurisdiction.I also certify that I understand that the regulations of other government agencies may apply to the intended work,and that it is my responsibility to identify what actions I must take to be In compliance.Such agencies Include but are not limited to: - Department of Environmental Protection-Cypress Bayheads,Wetland Areas and Environmentally Sensitive Lands,WaterMastewater Treatment. - Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. - Army Corps of Engineers-Seawalls,Docks,Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. - US Environmental Protection Agency-Asbestos abatement. - Federal Aviation Authority-Runways. I understand that the following restrictions apply to the use of fill: - Use of fill is not allowed in Flood Zone"V"unless expressly permitted. - If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume"will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. - If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction,I certify that fill will be used;only to fill the area within the stem wall. - if fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties,the owner may be cited for violating the conditions of the building permit issued under the attached permit application,for lots less than one (1) acre which are elevated by fill,an engineered drainage plan is required. If I am the AGENT FOR THE OWNER,I promise in good faith to inform the owner of the permitting conditions set forth In this affidavit prior to commencing construction.I understand that a separate permit may be required for electrical work,plumbing,signs,wells,pools,air conditioning,gas,or other installations not specifically included in the application.A permit issued shall be construed to be a license to proceed with the work and not as authority to violate,cancel,alter,or set aside any provisions of the technical codes,nor shall Issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans,construction or violations of any codes.Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance,or If work authorized by the permit is suspended or abandoned for a period of six(6)months after the time the work is commenced.An extension may be requested,in writing,from the Building Official for a period not to exceed ninety(90)days and will demonstrate justifiable cause for the extension.If work ceases for ninety(90)consecutive days,the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR-PROPERTY.IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT FLORIDA JURAT(F.S.117.03) OWNER OR AGENT CONTRACTO Su scribed ndbswo or affirmed)before rrge this S�ubsc;b bed s om to or affyme )before me this �y y 0/ n/w\�� o slate ersona known to me or has/have produced ho is/ar p sonally known t me or ha have produced as Identification. —� as identification. Notary Public utx�t��t�spJ�� Notary Public mission No. V� /�t�Z� Commission No. 97 b 1���� ,3 KEJ t/V 1�0 v�/�LL S K�YiN thL)1 t O''I� Name of Notary typed,printed or stamped Name of Notary typed,printed or stamped JAMES KEVIN HOWELL JAMES K:#G WELL log �B: ;otpR e�; Notary Public-State of Florida ;?; �= Notary Public of FloridaCommission q GG 910202Commissio910202My Comm.Expires Sep 4,2023 ?of F ` My Comm.Exep 4,2023 Bonded through National Notary Assn. Bonded through Naotary Assn. INSTR# 2021049919 Bt< 10299P� 1224 03/12/2021 09:37am Page 1 of 1 ,Permit Ni rube t r'15 t. z ~+ . 4 a Rcp 227236 Rec: 10.00 n � Parcel ID NumbereS?rl�-A6-ter,'(/��J��O-c70000-oa, v O`' 0.00 IT: 0.00 Nikki Alv z-Sowles Esq.NOTICE OF COMMENCEMENT Pasco County CJ k $Co111Ft roller Y i State of Floridatr`",n-_: : .1;i4„Y.G'�frF�};;:t�''y nri``�'?i::.:F.;:: ic,:+=1;�;�:�'i:' : r......e:. �r."•�". County of Ptmafterr�as THE UNDERSIGNED hereby.gives notice that improvements will be made to certain real property, and in accordance with Section 713.13 of the Florida Statutes,the following information is provided in this NOTICE OFCOMMENCZ7r- T. 1. Description of property(legal description):r�/a//�r�r/ %�s ONr, 3�P(S 4/7-4/9- e;,9i a3 •(a)Street(job)Address:(0 3 a 0O G r e_s+ we 1-kVrk/I(S. [_L_ 2.General description-of improvements: / - 3.Owner Information or Lessee information if the Lessee contracted for the improvement: 'ra)Name and address:S�kh S,, R-eel, 6 93_1 6akGreSt iJaV, Z e-pi(ph"Its, b)Name and address of fee simple titleholder(if different than Owner listed above) c)Interest in property:_ 4.Contractor Information a)Name and address: Lipton Window and Door2438 Merchant Ave Suite 103,Odessa,FL.33556 b)Telephone No.: 727-372-2455 Fax No.:(optional) 5.Surety(if applicable,a copy of the payment bond is attached) a)Name and address: b)Telephone No.: c)Amount of Bond:$ 6.Lender a)Name and address: b)Telephone No.: 7.Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by Section 713.13(1)(a)7.,Florida Statutes: a)Name and address: b)Telephone No.: Fax No.:(optional) 8.a)In addition to himself or herself,Owner designates of to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b),Florida Statutes. b)Phone Number of Person or entity designated by Owner: 9.Expiration date of notice of commencement(the expiration date may not be before the completion of construction and final payment to the contractor,but will be 1 year from the date of recording unless a different date is specified): ..20 WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1,SECTION 713.13, FLORIDA STATUTES,AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. Under penalty of perjury,I declare that I have read the foregoing notice of commencement and that the facts stated therein are true to the best of my knowl e a d belief. )Gigndt4 of Owner or Lessee,or Owner's or Lessee's(Authorized Officer/Director/Partner ager) f Pnnt Name and Provide Signator/sTitle/Office) The foregoing instrument was acknowledged before me by means of [physical presence or Lj on-line notarization,this day of 03 20 / by ( as f7T � (type of authority,e.g.officer,trustee,attorney in fact) <for 'Q—. 'i i S, ev� ,as 4 (Name of Person) (type of authority,e.g.officer,trustee,attomey in fact) for (name of party on behalf of om. ment wasexecuted). Personally Known ❑ Produced ID Type of ID ��O tl-'�7 ^ 041— D Notary Signature Print name 4 .✓ Notary Public State of Florida Shawn Duggan My Commission GG 826354 p* Expires 10/27/2023 COUNTY OF li�ASCO FFC A fir `"`�t' •`n STATEOFFLORIDA, m�• .��'yw,�,�. THIS IS TO CERTIFY THAT THE FOREGOING IS A TRUE AND CORRECT COPY OF THE DOCUMENT ON FILE OR OF PUBLIC RECORD IN THIS OFFICE ' =ESSY HAND AND OFFICIAL SEAL THIS '=�,��'=�-�. �^ Ti use DAY OF S 2 � NIKKI AREZ-S LE CLERK&CO MPTROL BY DEPUTY CLERK ; �l[ltiN �• K��L V4GU4T/OIJ= 7935� 3Z 64-Koz5g7- WAY Pw= 878q, ; zEP ye.r itLS. 27 . bnoP- 30lS` pal , booj2 Z = /J Z/31 /7 ti COOS, 10 �l! 3 OP SzXz3Vw 0 � _ 53X81 000P, _ ,�O,VT B usiness & Professional Regulation � YI�IYY_IYiIOA ... �4 SCIS Home I Log In I User Registration Hot Topics Submit Surcharge Stats&Facts Publications Contact Us SCIS Site Map Links search Gc , Product Approval 1f USER:Public User Product ADeroVal Menu>Product or Agpligatipn search>ggpligatlon List a ItppllcatlomDetall FL# FC8784-R13 Application Type oevislj� n Code Version 2020 Application Status IApproved—:: *Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by j the POC and/or the Commission if necessary. Comments Archived Product Manufacturer VI Win Tech Address/Phone/Email 2400 Irvin Cobb Drive Paducah,KY 42003 (270)538-4431 swheeler@vlwintech.com r Authorized Signature Steven Wheeler 4 swheeler@viwintech.com ` Technical Representative Steve Wheeler Address/Phone/Email 2400 Irvin Cobb Dr i Paducah,KY 42003 (270)538-4431 c swheeler@viwintech.com Quality Assurance Representative Ronnie WIlliams Address/Phone/Email 2400 Irvin Cobb Dr Paducah,KY 42003 (270)538-4437 1wlBllammss@viwintech.com l ows �. Category Vll�ows—....-- Subcategory CF7 d Compliance Method Certification Mark or Listing Certification Agency National Accreditation&Management Institute Validated By Scott Wolters,PE 0 Validation Checklist-Hardcopy Received Referenced Standard and Year(of Standard) Standard Year AAMA/WDMA/CSA101/I.S.2/A440 2008 r TAS 201 1994 TAS 202 1994 TAS 203 1994 9 t 1 Equivalence of Product Standards Certified By Florida Lkensed Professional Engineer or Architect FL8784 -U Eauiy FL8784 Eauivalencv pyf t E Product Approval Method Method 1 Option A 4 Date Submitted 12/30/2020 i• Date Validated 01/04/2021 Date Pending FBC Approval k Date Approved 01/12/2021 k Summary of Products I FL# Model,Number or Name Description k 8784.1 SL 31001 PW 7872 ShoreLlne Picture Window 3100 Profile,Impact,78x72. FW- I C60.SGP Innerlayer,Jamb, Fin,Flange Install, Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL8784 R13 C CAC NI008088.01-R9.pff Approved for use outside HVHZ:Yes FL8784 R13 C CAC NI008088.02-R9.D& Impact Resistant:Yes Quality Assurance Contract Expiration Date Design Pressure:+60/-60 05/31/2023 I Other:When used in HVHZ color of frames to be WHITE only Installation Instructions rigid PVC, FRAME MATERIAL TO BE RIGID PVC FROM VISION FL8784 R13 II 08-00204E.pd EXTRUSIONS LTD.AAMA CERTIFIED(VEX-1), "NOT TO BE Verified By: Luis R. Lomas,P.E. FL 62514 INSTALLED 30'OR HIGHER ABOVE GROUND LEVEL"-GLASS Created by Independent Third Party:Yes INTERLAYER COMPLIES WITH THE REQUIREMENTS OF THE Evaluation Reports iFLORIDA BUILDING CODE ACCORDING TO MIAMI-DADE NOA FL8784 R13 AE 511139-1E.plif FOR KURARAY(FORMERLY DUPONT)INTERLAYERS-"Safety Created by Independent Third Party:Yes Glass on outside pane required in HVHZ zones" f .84.2 SL 3300 PW-7272= j SHORELINi:.3ik,P f URA WIND0IN Llritlts of Use Certification Agency Certificate Approved for use In HVHZ:No FL8784 R13 C CAC NI009173.01-R6.Ddf Approved for use outside HVHZ:Yes 'FL8784 R13 C CAC NI009173-R7.pdf Impact Resistant: No Quality Assurance Contract Expiration Date Design Pressure: N/A 06/30/2023 I' Other:REFER TO APPROVAL DOCUMENT FOR DESIGN Installation Instructions PRESSURE RATINGS.FRAME MATERIAL TO BE RIGID PVC FROM FL8784 R13 II 08-00320C.R VISION EXTRUSIONS LTD.AAMA CERTIFIED(VEX-1), Verified By: Luis Roberto Lomas 62514 Created by Independent Third Party:Yes Evaluation Reports FL8784 R13 AE 510422D_pgf G Created by Independent Third Party:Yes Back rNext l li r Contact Us Tallahassee FL 32399 Phone:850-487-1824 a The State of Florida Is an �p AA/EEO employer. Ryjjeht 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,emall addresses are public records.If you do not want your e-mall address released In response to a public-records request,do not send electronic mall to this entity.Instead,contact the office by phone or by tmdltlonal mall.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1), Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an emall address If they have one.The emalis P provided may be used for official communication with the licensee.However emall addresses are public record.If you do not wish to supply a personal address,please 1 provide the Department with an emall address which can be made available to the public.To determine if you are a licensee under Chapter 455,F S.,please cllck here. Product Approval Accepts: f, ®® room CredifCar&.,'.­`T I I Ar REVISIONS REV DESCRIPTION DATE APPROVE A UPDATE TO 2007 FBC 1/17/09 R.L. 8 REVISED NOTES 3/09/12 R.L. C REVISED INSTALLATION DETAILS 07/20/15 R.L. NOTES: 15. FOR ANCHORING THROUGH FRAME INTO WOOD FRAMING OR 2X BUCK USE #10 WOOD 1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO REQUIREMENTS OF THE FLORIDA BUILDING CODE. SUBSTRATE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. 2. WOOD FRAMING AND MASONRY OPENING TO BE DESIGNED AND ANCHORED TO PROPERLY TRANSFER ALL LOADS TO STRUCTURE. FRAMING AND MASONRY OPENING IS THE 16. FOR ANCHORING THROUGH FRAME INTO MASONRY/CONCRETE USE 3/16" TAPCONS WITH RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE WITH 2 3. 1X BUCK OVER MASONRY/CONCRETE IS OPTIONAL. 1/2" MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND 4. WHERE SHIM OR BUCK THICKNESS IS LESS THAN 1-1/2" WINDOW UNITS MUST BE INSTALLATION DETAILS. ANCHORED THROUGH THE FRAME IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED 17. FOR ANCHORING THROUGH FRAME INTO METAL STRUCTURE USE #10 SMS OR SELF INSTALLATION INSTRUCTIONS. ANCHORS SHALL BE SECURELY FASTENED DIRECTLY INTO DRILLING SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE 3 THREADS MINIMUM BEYOND MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE MATERIAL. STRUCTURE INTERIOR WALL. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION 5. WHERE WOOD BUCK THICKNESS IS 1-1/2" OR GREATER, BUCK SHALL BE SECURELY DETAILS. FASTENED TO MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE. WINDOW UNITS MAY 18. ALL FASTENERS TO BE CORROSION RESISTANT. BE ANCHORED THROUGH FRAME TO SECURED WOOD BUCK IN ACCORDANCE WITH 19. INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS. MANUFACTURER'S INSTALLATION INSTRUCTIONS AND ANCHORS SHALL NOT BE USED IN 6. WHERE 1X BUCK IS NOT USED DISSIMILAR MATERIALS MUST BE SEPARATED WITH APPROVED SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BELOW: A. WOOD: MINIMUM SPECIFIC GRAVITY OF G=0.42 COATING OR MEMBRANE. SELECTION OF COATING OR MEMBRANE IS THE RESPONSIBILITY OF B. CONCRETE: MINIMUM COMPRESSIVE STRENGTH OF 2,000 PSI. THE ARCHITECT OR ENGINEER OF RECORD. C. MASONRY: HOLLOW/FILLED BLOCK PER ASTM C90 WITH f'm=2,OODPSI MINIMUM. 7. BUCKS SHALL EXTEND BEYOND WINDOW INTERIOR FACE SO THAT FULL FRAME SUPPORT IS D. METAL STRUCTURE: STEEL 18GA (.048") FY=33KSI/FU=52KSI OR PROVIDED. ALUMINUM 6063—T5 FU=30KSI 1/8" THICK MINIMUM 8. FOR FIN INSTALLATION SHIM AS NEEDED. FOR FRAME INSTALLATION SHIM AS REQUIRED AT 20.GEOMETRIC SHAPES ARE ALSO APPROVED. APPROVED GEOMETRIC SHAPES DIMENSIONS EACH ANCHOR LOCATION WITH LOAD BEARING SHIM. SHIM WHERE SPACE OF 1/16" OR SHALL NOT EXCEED INSCRIBED DIMENSIONS OF APPROVED RECTANGULAR ASSEMBLY SHOWN GREATER OCCURS. MAXIMUM ALLOWABLE SHIM STACK TO BE 1/4". IN SHEET 2. 9. SHIMS SHALL BE LOCATED, APPLIED AND MADE FROM MATERIALS AND THICKNESS CAPABLE OF SUSTAINING APPLICABLE LOADS. 10. WIND LOAD DURATION FACTOR Cd=1.6 WAS USED FOR WOOD ANCHOR CALCULATIONS. 11. FRAME MATERIAL: EXTRUDED RIGID PVC. 12. UNITS MUST BE GLAZED PER ASTM E1300-04, SEE SHEET 2 FOR GLASS DETAILS. 13. APPROVED IMPACT PROTECTIVE SYSTEM IS REQUIRED FOR THIS PRODUCT IN WIND BORNE DEBRIS REGIONS. 14. FOR ANCHORING THROUGH FIN INTO WOOD FRAMING OR 2X BUCK USE #8 WOOD SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. SIGNED:07/21/2015 VINYL WaooCIRVINEcoeBCD�vEES, INC ` 51P.I+`Z//z/'. PADUCAH, KY 42002 ��v•��CENs�9U+�`� TABLE OF CONTENTS SHORELINE SL 3100 PW 7272 =*• p„gy( fit= SHEEP N0. DESCRIPTION 72" X 72" NON IMPACT NOTES STATE OF "�� 1 NOTES DRAWN: DWG NO. REV 2 ELEVATIONS R.L. O8 s00E320 c 3 — 9 INSTALLATION DETAILSiscALENTS �� 7/25/07 1 OF 9 REVISIONS REV DESCRIPTION DATE APPROVED A UPDATE TO 2007 FBC 1/17/09 R.L. B REVISED NOTES 3/09/12 R.L. C REVISED INSTALLATION DETAILS 07/20/15 R.L. 72" MAX FRAME WIDTH 72" MAX FRAME WIDTH 6" MAX rT MAX O.C. 6" MAX 6" MAX MAX 20.C. '{ 6" MAX 6" MAX 6" MAX MAX O.C. 12" I MAX O.C. 72" MAX T MAX MAX FRAME FRAME HEIGHT HEIGHT 6" MAX 6" MAX SHORELINE SL 3100 PW 7272 SHORELINE SL 3100 PIN 7272 EXTERIOR VIEW EXTERIOR VIEW FRAME FLUSH INSTALLATION FIN INSTALLATION DESIGN PRESSURE RATING IMPACT RATING DESIGN PRESSURE RATING IMPACT RATING ±95.OPSF NONE ±70.OPSF NONE SIGNED:0712112015 NOTES: VINYL WINDOW TECHNOLOGIES, INC 1. MAXIMUM D.L.O.: 72 1/4" X 66 1/2" J < PADUCAH, KY 42002 `.r••��GENs�'9s+<� SHORELINE SL 3100 PW 7272 *•. 0;;6�'b yt 72" X 72" NON IMPACT ELEVATIONS ' STATE.OF DRAWN: DWG NO. REV ��•.�C R.L.ALE DATE 08 SOOE320 c NTS 7/25/07 2 OF 9 REVISIONS 1/2" MIN. REV DESCRIPTION DATE APPROVED EDGE DISTANCE 3/4" MIN A UPDATE TO 2007 FBC 1/17/09 R.L. WOOD FRAMING EDGE DISTANCE I B REVISED NOTES 3/09/12 R.L. OR 2X BUCK I I BY OTHERS 1 1/4" MIN. 1/4" MAX. (IREVISED INSTALLATION DETAILS 07/20/15 R.L. EMBEDMENT METAL SHIM SPACE t STRUCTURE BY OTHERS BACKER ROD O a 1/4" MAX. APPROVED & APPROVED SHIM SPACE SEALANT SEALANT n El O #10 SMS OR #10 WOOD SCREW SELF DRILLING SCREW EXTERIOR INTERIOR EXTERIOR INTERIOR #10 WOOD SCREW #10 SMS OR SELF DRILLING ❑ � ❑ SCREW BACKER ROD BACKER ROD �� & APPROVED 1/4" MAX. & APPROVED SEALANT SHIM SPACE SEALANT 1/4" MAX. O SHIM SPACE WOOD FRAMING METAL OR 2X BUCK STRUCTURE BY OTHERS 1 MIN. BY OTHERS EMBEDMENT 3/4" MIN. 1/2" MIN. EDGE DISTANCE EDGE DISTANCE VERTICAL CROSS SECTION VERTICAL CROSS SECTION WOOD FRAMING OR 2X BUCK INSTALLATION METAL STRUCTURE INSTALLATION HEAD AND SILL SHOWN,JAMBS SIMILAR HEAD AND SILL SHOWN,JAMBS SIMILAR SIGNED:0712112015 VINYL Waoo�RVINEcOBBODROIVEES, INC \N%RI!Lo ' NOTES: PADUCAH, KY 42002 `r,•v\GENS�,•S+,/� 1. INTERIOR AND EXTERIOR FINISHES,BY OTHERS, �' NOT SHOWN FOR CLARITY. SHORELINE SL 3100 PW 7272 *• 0 � 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE 72" X 72" NON IMPACT �,0 � C DESIGNED IN ACCORDANCE WITH ASTM E2112 FLUSH INSTALLATION DETAILS TAT OF tv� i�.c`•� `ki` DRAWN: DWG N0. REVIORIOP SALE NTS DATE 7/25/07 08 SHEET 3300F 9 C ,/��%/jONA',�?\���_ REVISIONS 2 1/2" MIN. �{ REV DESCRIPTION DATE I APPROVED EDGE DISTANCE I A UPDATE TO 2007 FBC 1/17/09 R.L CONCRETE/MASONRY I B REVISED NOTES 3/09/12 R.L. BY OTHERS `° C C REVISED INSTALLATION DETAILS 07/20/15 R.L. C° a ° ° ° 1 1/4" MIN. OPTIONAL 1 X BUCK " ' ° ° ° G `< EMBEDMENT SEE NOTES 3 — 7 SHEET 1 BACKER ROD & APPROVED 1 MAX. SEALANT SHIM SPACE O ❑ D 3/16" TAPCON -------EXTERIOR-- - INTERIOR BACKER ROD O 3/16" TAPCON & APPROVED IJ� SEALANT UU OPTIONAL 1 X BUCK 1/4" MAX. SEE NOTE 3 — 7 SHIM SPACE SHEET 1 CONCRETE/MASONRY BY OTHERS 1 . ° a NOTES: 4' EMBEDMENT 1. INTERIOR AND EXTERIOR FINISHES,BY OTHERS, a ° ° NOT SHOWN FOR CLARITY. a 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE G DESIGNED IN ACCORDANCE WITH ASTM E2112 2 1/2" MIN. EDGE DISTANCE SIGNED:0712112015 VERTICAL CROSS SECTIONCONCRET&MASONRY INSTALLATION VINYL WINDOW TECHNOLOGIES INC HEAD AND SILL SHOWN,JAMBS SIMILAR 2400 IRVINCAH, K COBB DRIVE . �. GENB:yd+�� SHORELINE SL 3100 PW 7272 ir• p *k 72" X 72" NON IMPACT �GC� FLUSH INSTALLATION DETAILS : • TAT OF °t�� DRAWN: DWG NO. REV O�•• C P • \ R.L. 08-00320 C ���sS OR`OGI�G\��\ SCALE NTS DATE 7/25/07 SHEET4 OF 9 / 'ONA;11�`��` i i REVISIONS 1/2" MIN. REV DESCRIPTION DATE APPROVED ' EDGE DISTANCE 3/4" MIN A UPDATE TO 2007 FBC 1/17/09 R.L. WOOD FRAMING EDGE DISTANCE B REVISED NOTES 3/09/12 R.L OR 2X BUCK BY OTHERS 1 1/4" MIN. 1/4" MAX. C REVISED INSTALLATION DETAILS 07/20/15 R.L. EMBEDMENT METAL SHIM SPACE t { STRUCTURE BY OTHERS BACKER ROD 1/4" MAX. APPROVED & APPROVED SHIM SPACE SEALANT SEALANT CID ❑ O O #10 SMS OR #10 WOOD SCREW SELF DRILLING SCREW EXTERIOR INTERIOR EXTERIOR INTERIOR #10-SMS OR .#10 WOOD SCREW - - - - - - - --- - - - - - - ----- n SELF DRILLING SCREW �� BACKER ROD BACKER ROD & APPROVED 1/4" MAX. APPROVED SEALANT SHIM SPACE SEALANT 1/4" MAX. SHIM SPACE WOOD FRAMING METAL OR 2X BUCK STRUCTURE r BY OTHERS 1 BED MIN. BY OTHERS I EMBEDMENT t� 3/4" MIN. 1/2" MIN. EDGE DISTANCE EDGE DISTANCE VERTICAL CROSS SECTION VERTICAL CROSS SECTION WOOD FRAMING OR 2X BUCK INSTALLATION METAL STRUCTURE INSTALLATION HEAD AND SILL SHOWN,JAMBS SIMILAR HEAD AND SILL SHOWN,JAMBS SIMILAR SIGNED:07/21/2015 VINYL WINDOW TECHNOLOGIES, INC J•`5y 1 'NlSF 1•iRLp�aooRVINcoesDvE NOTES: ` PADUCAH, KY 42002 1. INTERIOR AND EXTERIOR FINISHES,BY OTHERS, NOT SHOWN FOR CLARITY. SHORELINE SL 3100 PW 7272 f 0' 1 2. PERIMETER AND JOINT SEALANTBY OTHERS TO BE 72" X 72" NON IMPACT DESIGNED IN ACCORDANCE WITH ASTM E2112 FLANGE INSTALLATION DETAILS � AT DRAWN: DWG NO. REV /O• P•• \. R.L. 08-00320 C OR�O'l1G`t�� SCALE NTS DATE 7/25/07 ISHEET5 OF 9 REVISIONS 2 1/2" MIN. —�{ REV DESCRIPTION DATE 11 APPROVED , EDGE DISTANCE I A UPDATE TO 2007 FBC 1/17/09 R.L. CONCRETE/MASONRY I B REVISED NOTES 3/09/12 R.L. BY OTHERS - °p e C REVISED INSTALLATION DETAILS 07/20/15 R.L. a ° ° 1 1/4" MIN. OPTIONAL 1 X BUCK ° ° ° a EMBEDMENT SEE NOTES 3 — 7 SHEET 1 BACKER ROD& APPROVED 1/4" MAX. SEALANT SHIM SPACE D3/16" TAPCON EXTERIOR INTERIOR BACKER ROD 3/16" TAPCON & APPROVED f7� SEALANT UU OPTIONAL 1X BUCK 1 MAX. SEE NOTE 3 — 7 SHI M M SPACE SHEET 1 CONCRETE/MASONRY 1 BY OTHERS ° ° a NOTES: EMBEDMENT 1. INTERIOR AND EXTERIOR FINISHES,BY OTHERS, °' NOT SHOWN FOR CLARITY. ° G ° ° '° 2. PERIMETER AND JOINT SEALANT BYOTHERS TO BE n DESIGNED IN ACCORDANCE WITH ASTM E2112 2 1/2" MIN. EDGE DISTANCE SIGNED:0712112015 VERTICAL CROSS SECTION VINYL WINDOW TECHNOLOGIES INC 11 i CONCRETEIMASONRYINSTALLATION 2IND IRVIN COBS DRIVE "\\\\`51RIIt0%Y/// HEADANOSILLSHOWN,JAMBSS/MILAR PADUCAH, KY 42002 `�"`��CEAf,* +�y SHORELINE SL 3100 PIN 7272 72" X 72" NON IMPACT FLANGE INSTALLATION DETAILS 0;. T OF DRAWN: DWG N0. REV // �[pR10Q:G\�\ GALE DATE 08 SOOE320 C /11 NITS 7/25/07 6 OF 9 REVISIONS 1/2" MIN. REV DESCRIPTION DATE APPROVED ` EDGE DISTANCE 3/4" MIN A UPDATE TO 2007 FBC 1/17/09 R.L. WOOD FRAMING EDGE DISTANCE I I B REVISED NOTES 3/09/12 R.L. OR 2X BUCK I I C REVISED INSTALLATION DETAILS 07/20/15 R.L. BY OTHERS 1 1/4" MIN. 1/4" MAX. EMBEDMENT METAL SHIM SPACE 1 STRUCTURE BY OTHERS BACKER ROD 1/4" MAX. APPROVED 0 a & APPROVED SHIM SPACE SEALANT SEALANT E) o #10 SMS OR #10 WOOD SCREW SELF DRILLING SCREW EXTERIOR INTERIOR EXTERIOR INTERIOR #10 WOOD SCREW - - --- O #10 SMS OR SELF DRILLING SCREW �� BACKER ROD BACKER ROD & APPROVED 1/4" MAX. & APPROVED SEALANT SHIM.SPACE SEALANT 0 1/4" MAX. SHIM SPACE WOOD FRAMING METAL OR 2X BUCK STRUCTURE —� BY OTHERS 1 MIN. BY OTHERS EMBEDMENT 1/2" MIN. 3/4" MIN. EDGE DISTANCE EDGE DISTANCE VERTICAL CROSS SECTION VERTICAL CROSS SECTION WOOD FRAMING OR 2X BUCK INSTALLATION METAL STRUCTURE INSTALLATION HEAD AND SILL SHOWN,JAMBS SIMILAR HEAD AND SILL SHOWN,JAMBS SIMILAR SIGNED:0712112015 VINYL WaooCIRVINEcoBBCD�VEES, INC \\`\�`s��Rl�.�/0 ����, NOTES. PADUCAH, KY 42002 "`ter•v\CENSF'9s��, 1. INTERIOR AND EXTERIOR FINISHES,BY OTHERS, NOT SHOWN FOR CLARITY. SHORELINE SL 3100 PW 7272 o 6�Jj�''_ •,*� 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE 72" X 72" NON IMPACT t DESIGNED INACCORDANCE WITH ASTM E2112 FRAME INSTALLATION DETAILS �yD• TAT OF DRAWN: DWG N0. REV SCALE DATE 08 s00E320 C �� NA 1`�;\\��\ NTS 7/25/07 7 OF 9 REVISIONS 2 1/2" MIN. REV DESCRIPTION DATE 'APPROVED , EDGE DISTANCE A UPDATE TO 2007 FBC 1/17/09 R.L. CONCRETE/MASONRY B REVISED NOTES 3/09/12 R.L. BY OTHERS C REVISED INSTALLATION DETAILS 07/20/15 R.L. a 1 1/4" MIN. OPTIONAL 1X BUCK ° ° G' 'd EMBEDMENT SEE NOTES 3 — 7 SHEET 1 BACKER ROD & APPROVED 1 MAX. SEALANT SHIM SPACE O 3/16" TAPCON EXTERIOR INTERIOR BACKER ROD O 3/16" TAPCON & APPROVED ( 7� SEALANT1/4" UU OPTIONAL IX BUCK HIM MAX. SEE NOTE 3 — 7 SHIM SPACE SHEET 1 —7 CONCRETE/MASONRY BY OTHERS ° ° ° a NOTES: 1EMBEDMENT 1. INTERIOR AND EXTERIOR FINISHES,BY OTHERS, n NOT SHOWN FOR CLARITY. a 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE a DESIGNED IN ACCORDANCE WITH ASTM E2112 2 1/2" MIN. EDGE DISTANCE SIGNED:0712112015 VERTICAL CROSS SECTIONCONCRET ASONRY INSTALLATION VINYL WINDOW TECHNOLOGIES INC �Illulrrlli HEAD AND�SHOWIV,JAMBS SIMILAR 2400 IN COBB DRIVE PADUCA KY 42002 SHORELINE SL 3100 PW 7272 _*• 0;;66 7M X 72" NON IMPACT ^'� C FRAME INSTALLATION DETAILS !gt• $TAT OF •ty� DRAWN; DWG N0. REV O •'QC,OIRIOCQ;`�IF-1 SCALE NT$ DATE 7/2rJ/07 DB SOOE3800F 9 D ',,,/ss101fAl 'E\X\N REVISIONS APPROVED REV DESCRIPTION DATE APPROVED SEALANT BEHIND FIN 1 1/4" MIN. A UPDATE TO 2007 FBC 1/17/09 R.L. WOOD EMBEDMENT B REVISED NOTES 3/09/12 R.L. #8 WOOD FRAMING SCREW BY OTHERS C REVISED INSTALLATION DETAILS 07/20/15 R.L. 7/16" MIN EDGE DISTANCE 1/4" MAX. SHIM SPACE a 0 p EXTERIOR INTERIOR O 1/4" MAX SHIM SPACE 7/16" MIN EDGE DISTANCE NOTES. #8 WOOD WOOD 1. INTERIOR AND EXTERIOR FINISHES,BYOTHERS, NOT SHOWN FOR CLARITY. SCREW 1 1/4" MIN. BYAOTHERS 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE APPROVED EMBEDMENT DESIGNED IN ACCORDANCE WITH ASTM E2112 SEALANT BEHIND FIN VERTICAL CROSS SECTION WOOD FRAMING OR 2X BUCK INSTALLATION HEAD AND SILL SHOWN,JAMBS SIMILAR SIGNED:0712112015 VINYL WINDOW TECHNOLOGIES, C � ES, INC ` •S�\�+EI\ aooRVINcBBDVE `` \ PADUCAH, KY 42002 SHORELINE SL 3100 PW 7272 *• p 77 c•0�9k X 72" NON IMPACT FININ AT INSTALLATION DETAILS �yD• TAT OF `y� DRAWN: DWG NO. REV �s'c[pR10P,G�\� SCALE DATE 08 500320 C 'VA"0a\�`\ NTS 7/25/07 9 OF 9if 1 4.a i 7'F'k° to •`�.� ® � • S Y tl ® m ® tl •0 BCIS Home I Log In I User Registration I Hot Topics I Submit Surcharge I Stats&Facts I Publications I Contact Us BCIS Site Map Links I Search a as Product Approval ,� iS5 USER:Public User d,0Si Product Approval Menu>Product or Application Search>Application List>Application Detail ® FL# FL15213=R4 Application Type Revision. Code Version 2020 Application Status Approved Comments Archived !�1 Product Manufacturer Plastpro Inc./Nanya Plastics Corp. Address/Phone/Email 5200 W CENTURY BLVD. LOS ANGELES,CA 90045 (440)969-9773 Ext16 rickw@rwbldgconsuitants.com Authorized Signature Vivian Wright rickw@rwbldgconsultants.com Technical Representative Scott Johnson Address/Phone/Email 5200 W Century Blvd. Los Angeles,CA 90045 (440)969-9773 Ext18 scottjohnson@plastproinc.com Quality Assurance Representative Ron O'Connell Address/Phone/Email 5200 W Century Blvd. Los Angeles,CA 90045 (440)969-9773 Ext16 ronoconnell@plastpro.com Category Exterior_Doors, t .rter.rs, _. ., .. Subcategory Swinging Exterior Door Assemblles Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed the Lyndon F. Schmidt, P.E. Evaluation Report Florida License PE-43409 Quality Assurance Entity National Accreditation and Management Institute Quality Assurance Contract Expiration Date 12/31/2021 Validated By Ryan J. King, P.E. .) Validation Checklist-Hardcopy Received Certificate of Independence FL15213 R4 COI (c)Certificate of Independence.pd Referenced Standard and Year(of Standard) Standard Year 101/I.S.2 1997 101/I.S.2/NAFS 2002 ASTM E1886 2002 ASTM E1886 2005 ASTM E1996 2009 ASTM E1996 2002 ASTM E330 2002 additional use limitations,installation instructions and product FL15213 R4 AE (b),Eval 15213.11,12d particulars. Created by Independent Third Party:Yes 15213.12 1.Smooth/Wood Grain/White Wood 6'8"Nan-Impact"Glazed Fiberglass Double Door utilizing "Snap Grain/Rustic/Mahogany Series N Frame"Glazing-Inswing/Outswing(XX-Configuration) Fiberglass Door Limits of Use Installation Instructions Approved for use in HVHZ: No FL15213 R4 II (b) Inst I5213.12.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt,RE.43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other:See INST 15213.12 for Design Pressure Ratings,any FL15213 R4 AE (b) Eval 15213.12.pdf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 15213.13 m.Smooth/Wood Grain/White Wood 6'8"Non-Impact"Glazed Fiberglass Double Door with Sidelites Grain/Rustic/Mahogany Series N utilizing "Snap Frame"Glazing-Inswing/Outswing(OXXO- Flberglass Door Configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No FL15213 R4 II (b) Inst 15213.13.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other:See INST 15213.13 for Design Pressure Ratings,any FL15213 R4 AE ( Eval 15213.13.pdf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 15213.14 n.Smooth/Wood Grain/White Wood 6'8"Non-Impact"Glazed Fiberglass Single Door utilizing"Lip Grain/Rustic/Mahogany Series N Lite"Glazing-Inswing/Outswing (X-Configuration) Fiberglass Door Limits of Use Installation Instructions Approved for use in HVHZ: No FL15213 R4 1 (b) Inst 15213.14.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other:See INST 15213.14 for Design Pressure Ratings,any FL15213 R4 AE (b)Eval 15213.14.pd additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 15213.15 _ _, o. Smooth/Wood Grain/White Wood 6'8"Non-Impact"Glazed Fiberglass Single Door with Sldelite Grain%Rustic%Mahogany Series N`' ''Utilizing."Lip-Llte"Glazing-Inswing/Outswing (OX or XO- 1 -Fiberglass Door Configuration"s) -^ - Limits of Use Installation Instructions Approved for use in HVHZ: No FL15213 R4 II (b)Inst 15213.15.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F Schmidt,P.E.43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other:See INST 15213.15 for Design Pressure Ratings,any FL15213 R4 AE (b)Eva) 15213.15.pldf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 15213.16 p. Smooth/Wood Grain/White Wood 6'8"Non-Impact"Glazed Fiberglass Single Door with Sideiites Grain/Rustic/Mahogany Series N utilizing"Lip Lite"Glazing-Inswing/Outswing (OXO- Fiberglass Door Configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No FL15213 R4 II (b)Inst 15213.16.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt, P.E.43409 Impact Resistant: No Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other:See INST 15213.16 for Design Pressure Ratings,any FL15213 R4 AE (b)Eval 15213.16.pdf additional use limitations, installation instructions and product Created by Independent Third Party:Yes particulars. 15213 17__- — q.-Smo`oth%Wood Grain/White Wood 6'8"Non-Impact"Glazed Fiberglass Double Door utilizing"Lip Grain/Rustic/Mahogany Series N Lite"Glazing-Inswing/Outswing(XX-Configuration) Fiberglass Door Limits of Use Installation Instructions Approved for use in HVHZ: No FL15213 R4 Ii (b)Inst 15213,17.pd Approved for use outside HVHZ:Yes Verified By: Lyndon F Schmidt,P.E.43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other:See INST 15213.17 for Design Pressure Ratings,any EL15213 R4 AE (b}Eva[15213.17.pd additional use limitations, installation instructions and product Created by Independent Third Party:Yes particulars. 15213.18 r. Smooth/Wood Grain/White Wood 6'8"Non-Impact"Glazed Fiberglass Double Door with Sidelites Grain/Rustic/Mahogany Series N utilizing"Lip Lite"Glazing-Inswing/Outswing(OXXO- Fiberglass Door Configuration) TAS 201,202,203 1994 Equivalence of Product Standards Certified By Florida Licensed Professional Engineer or Architect FL15213 R4 Eauiv of Standards(d),.p_df Sections from the Code Product Approval Method Method 1 Option D Date Submitted 07/21/2020 Date Validated 08/25/2020 Date Pending FBC Approval 08/26/2020 Date Approved 10/13/2020 Summary of Products Go to Page = 0 (0 Page 1/2 Y� FL# Model,Number or Name Description 15213.1-----•-- --- -;a Smooth/Wood-Grain/White Wood -6.'8 Impact!'-Opaque Fiberglass Single Door- Grairi%R'ustic%Ma ogf-i any Series- Inswing/Outswing( rati�on) Fiberglass Door Limits of Use Installation Instructions Approved for use in HVHZ: No FL15213 R4 II (b)Inst 15 113.1 pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt, P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other:See INST 15213.1 for Design Pressure Ratings,any FL15213 R4 AE Eval 15213.1.pd additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 15213.2 b, Smooth/Wood Grain/White Wood 6'8"Impact"Opaque Fiberglass Single Door with Sidelite Grain/Rustic/Mahogany Series utilizing"Snap Frame"Glazing -Inswing/Outswing(OX or XO- Fiberglass Door Configurations) Limits of Use Installation Instructions Approved for use In HVHZ: No FL15213 R4 II (j?)Inst 15213.2.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt, P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other:See INST 15213.2 for Design Pressure Ratings,any FLi5213 R4 AE (b) Eval 15213.2.pdf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 15213.3 c. Smooth/Wood Grain/White Wood 6'8"Impact"Opaque Fiberglass Single Door with Sidelites Grain/Rustic/Mahogany Series utilizing"Snap Frame"Glazing-Inswing/Outswing (OXO- Fiberglass Door Configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No FL15213 R4 II W Inst 15213.3.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other:See INST 15213.3 for Design Pressure Ratings,any FL15213 R4 AE (b)Eval 15213.3.pdf additional use limitations,installation instructions and product Created by Independent Third Party: Yes particulars. 15213.4 d.Smooth/Wood Grain/White Wood 6'8"Impact"Opaque Fiberglass Single Door with Sidelite Grain/Rustic/Mahogany Series utilizing"Lip Lite"Glazing-Inswing/Outswing (OX or XO- Fiberglass Door Configurations) Limits of Use Installation Instructions Approved for use in HVHZ: No FL15213 R4 II (bJ Inst 15213.4.p_df Approved for use outside HVHZ:Yes Verified By: Lyndon F Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other:See INST 15213.4 for Design Pressure Ratings,any FL15213 R4 AE (¢J Eval 15213.4.pdf additional use limitations, installation instructions and product Created by Independent Third Party:Yes particulars. 15213.5 e. Smooth/Wood Grain/White Wood 6'8"Impact"Opaque Fiberglass Single Door with Sidelites Grain/Rustic/Mahogany Series utilizing "Lip Lite"Glazing-Inswing/Outswing (OXO- Fiberglass Door Configuration) Iasipro p - �• �•-tlI ,o L'J=b M 5200 W. CENTURY BLVD. _U A 52 75"Max OVERALL =w titAMEwtDTH LOS ANGELES CA 90045 1s25"MAX ',,��• •,•• ?°Z FRAME WIDTH i��i�''T * \\� i n m 11 1\\ 8 N..10 Smooth/ Wood Grain / White Wood Grain § o to 9 m'W Rustic/Mahogany a N m a a Series N Fiberglass Door' € oZ INSWING/OUTSWING 'NON-►MPACr' Z Z A Z Q tnZ SE ci p(9 �Q 2A = 0 GENERAL NOTES - -- y O N Ed 1. This product has been evaluated and_is in compliance with the 7th Edition(2D20)Florida /� ® �m Building Code(FBC)structural requirements excluding the"High Velocity Hurricane Zone" Q o a w �W (HVHZ) o o ¢ a 2. Product anchors shall be as listed and spaced as shown on details.Anchor embedment to ¢ a a base material shall be beyond wall dressing or stucco. m fV � 3. When used in areas requiring wind bome debris protection this product is required to be protected with an impact resistant covering that complies with FBC Sections 1609.1.2& 12 T R301.21.2 0F.i N ^ O O O 4. For 2x stud framing construction,anchoring of these units shall be the some as that shown for z 2x buck masonry construction. w W Ln 5. Site conditions that deviate from the details of this drawing require further engineering analysis Q o 0 by a ricensed engineer or registered architect. TABLE OF CONTENTS SHEET• DESCRIPTION a O1 1 Typical elevation,design pressures,&general notes N^ w z Door panel details N o ,:;::._;,; :::: :;::cveha�1:::::_ noon-::_ S1pElJfE;:;;;::: DESIGN:RRESSURE: s.< ^ z 3 Sidelrte,panel detals :.:...__. ... .:,.,..,: :.:::..:::.. ......... ......_.....:: �1.. o 63 4 Horizontal cross sectionsYP D:LQ« POSITNE.:--.NEGA7NE,.;; 5 Vertical cross sections -::=::_DIMENSfON_:' _;::flfWIEN_.SION:_:::>3::DTMENSION _.:. :._.._... �02 16/12 z -- ... _ 6 Vertical cross sections INSWING 52.75"x 82.0" 21.0"x 63.0" 7.0"x 63.0" +48.0 -50.0 s - N.T.S. 2 7 Buck and frame anchoring-2X buck masonry construction Gl UM BY: JK m' B 1 Frame anchoring-1 X buck masonry construction arx.rn, LFS. 4. 9 Bill of materials,glazing decal 8 components OUTSWING 52.75"x BOX 21.0"x 63.0" 7.0"x 63.0" +50.0 -50.0 � DPAWUIC NO.: FL-15213.15 ro 0 SHEET__L OF J R:\Clients\Plastpro,Inc PERMANENT\A-Florida Product ApprwalsVI.-15213 Fiberglass Door-Inswing-OutsWng\C-Drawings\FL 15213(2020)\FL-15213.12-10.dwg,2.15 79.2,r MAX.DOOR PANEL HEIGHT 63.0"MAX.�D.L.O.HEGHT —{ d0 pa x o V `3 P1.75 g-�_7 32 pa v alp ® o I° � x � O r �0 w a cT-o a tT A Z Z 0 0 Yn'rt� . > 7=C 3 a �z a (� z Z m rn K r m n n rn v O ro -o NN A O. a s n . ,,ttNltrttrp/ A No.43409 0 P August 5,2020 .t PRODUCT: Doaum.nt. Proparod r Lyndon F. So hmtdtfZCRlQF••••• .ym. P.E. No. 43409 �i $'•........ IN ro PLASTPRO INC. / ��NAL N z 3 7 27 zo UPDATE To 7TH ED. 2020 F&C LFs FIBERGLASS DOOR /� rrrrtuttltt� Z 10 19 T7 UPDATE TO 67H ED. 2017 FBC tF'S PART OR ASSET SLY: �K BUILDING CONSULTANTS, INC. Ito w x •L~1 � 7 4 22 15 UPDATE TO 5TH ED. 2014 FBC JK J IC �n N NO DATE By DOOR PANEL DETAILS yv P•O. Box 230. Voldco, FL 33595 Phone No.: 813.559.9197 REVISIONS FBPE Registry No. 9813 •0'dOl9 R.W.BIlII.DINa CG NeL1LTANTe INo. R.,\Clients\Plastpro,Inc PERMANENM-Florida Product Approvals\FL-15213 Fiberglass Door-Inswing-Outswlng\C-Drawings\FL 15213(2020)\FL-15213,12-18.dwg,3.15 79.25"MAX,SIDELITE PANEL HEIGHT 0 63,0r MAX.D.L.O.HEIGHT ro Ovs 0 22 < ri S; x 0 1 0 0 0 1.75' Q Z'- > 00 2!: C)::� D? 50 z M -G 00 .... ...... >0 ;0 z 0 1 > > 0 M M ;v m m m m 0 m 0 I gS: Q F Is9m 22 C'. Z No,43409 August 5,2020 JAI PRODUCT. 11—urnants=d "I, Lyndon F. cit. PLASTPRO INC. P.E. No. 43409 • LFS FIBERGLASS DOOR ICA U1 -71-2 772 5 UPDATE To 77H ED. 16-�KONAL L, 1-1 10/19/17 UPDATE TO 6TH ED. PART OR ASSEMBLY: BUILDING CONSULTANTS. INC. in 04/22/15 UPDATE TO 5TH ED. (2014) FOC P•0. Box 230, VoIricc, FL 33595 i� -R-0. 'I' SMELITE PANEL DETAILS r.n DATE JBY P,hona No.: 813.659.9197 —REVISIO"- MPE Registry No. 9813 02012 R.W.B—DING CONSULTANTS INC. 1 2rl'V 2 1-1/47MIN. 5 5 6 6 EMB.(TYP.) `�Q'�r •� m m ' SEE =Z•a�' o&:.J�=n 4 4 $0 35 M NOTEI =U * bla—'r! INTERIOR i 21 20 ao m 20 21 'v%: /// /%/ q 8 M °v , ` a N NOTE 1 EXTERIOR '''��«tfi 11� d — EXTERIOR 7 1 18 3 N 3 z ° ^ 4 o N og 9p`oa m dad 4 x EXTERIOR w E� � o � ��I 21 20 oa INTERIOR / 4 17 13 35 50 /// /// Cr U INTERIOR 40 27 i i J Z o V) C om o z Ln g> 4 HORIZONTAL CROSS SECTION 4 D �1 HORIZONTAL CROSS SECTION E 3 w ¢ Q Inswing configuration 4 Shown w/1Xsubbuck am E- o 3 4 3 4 y 5 6 6 EMB.(1YP.J o 1-1/4"MIN. 5 _ o' EMB.(TYP.) NOTE: E �a a 1.SideGte panel secured to the sidelite 0 frame with(4)of item#M located �S m C 0.15" 10".30.5,5 1"and 71.5"from top of M SEE p ° CSINK each jamb and(2)of item#M in SEE NOTE 1 L I (TYP.) the head,3"from each end L NOTE 1 M 35 50 50 35 fn E°la a I INTERIOR o n � 20 21 21 20 ° N N N N N y Z N ] 8 000 40 INTERIOR 7 W W a ��o EXTERIOR L o n m m a N W Z 20 21 `o W Z I Z U CSINK a,E 02 16/12 0 R 10 EXTERIOR 13 sue: N.T.S. 8 11 40 y] ) C 8 owc.er: JK m o9J cxK er: LFS 3 E 1 HORIZONTAL CROSS SECTION �1 HORIZONTAL CROSS SECTION 3 HORIZONTAL CROSS SECDON o MD•: 4 Ougn shown-Inswi CQJOuts hgconfi configuration N olso approved g 4 al o approved inswing F1-15213.15 N 0 Vsrtfr 4 or 9 R:\Cllents\Plastpro,Inc PERMANENT\A-Florida Product Approvals\FL-15213 Fiberglass Door-Inswing-Out swing\C-Drawings\FL 15213(2020)\FL-15213.12-18dwg,5.15 1-1/4"MIN. EMB.(TYP.) m 0 ww g m g n W • A A oc 00T: Q t11 • � .i G ro n .T m ti 3 Z m Z m m 2 ° r ao A _ IA ' ♦ oG . • ; �. a. 0.15" + C'SINK • ° m FYN r 0' 1-1/4"MIN. EMB,(TYP.) 1-XMIN. EMB.(TYP.) .. m . • v a p T O a V A • °. X n ° ,•�. w � c y ,�. G ;13 n n <' 0 r .° 2 • IF n ..' � CD ,. m e a D ° 0 n m 1-1/4"MIN. EMB.(TYP.) 8CH►Fi��� i No.43409 August 5,2020 a v oP PRODUCT: Dooum�rd�PnpanE Lyndon. E. No F43409 m! '��/ S"t«RDN,,.• ``�� I g g N PLASTPRO INC. IN Cn Z 3 7 27 20 UPDATE TO 7TH ED. 2020 FBC LFS FIBERGLASS DOOR 2 10 19 17 UPDATE TO 6TH ED. 2017 FBC LFS PART OR ASSEMBLY: BUILDING CONSULTANTS, INC. It ( to x '~i1\ 1 VERTICAL 04 22 15 UPDATE TO 5TH ED. 2014) FBC JK CROSS SECTIONS P.O. Box 230. Volrloo, Fl.33595 iv NO DATE gY Phone No.: 813.559.9197 REVISIONS FBPE Reglaby No. 9813 • 0 201 2 R.W.BUILDING CONSULTANTS IN.. R:\06entAPlastpro,Inc PERMANENT\A-Florida Product Approvals\FL-15213 Fiberglass Door-Inswing-Outswing\C-Drawings\FL 15213(2020)\FL-15213.12.18.dwS 6.15 1-1/4"MIN. m EMS.(CYP.) C w • 4 -n 0.15, e— C`SINK +1 a + o W (TYP-) I s I� Qrn z 0o rlip o .. . p O O z N W. A -ap 4 m m a 1-1/4'MIN. EMS.(TYP.) z W� H �n � Qrn 3 m�04 re i ID C ' 3 a p((a 0.'3 00 @ 3o0m. a In �0Q. m rn 1-1/4"MIN. > EMS.(TYP.) r. +p au o•A � v � rn O z 7rp �� °. ti•• � Qvr �� a..• �~ O �7n0 d VO 012 �s c n' ^} o- MN � °' 'P rn � 4 •. . Cl Z �+' 3• n Z IQ p m Z 1-1/4"MIN. ,Q• o �A EMS.(TYP.) No.43409 August 5.2020 g P1 PRODUCT: Documontb PmPorod ey.� ; Lyndon F. Schmidt �p••�•: WON••• \��, IO1 I N PLASTPRO INC. P.E. No. 43409 YQNAL ��\ N -Z-i J 7 27 20 UPDATE TO 7TH E0. 2020 FOC LFS F2 R SS OOR /� 2 10119117 UPDATE TO 67N ED. 2017)FE1G LFS PART OR ASSEMBLY: x��f BUILDING? CONSULTANTS. INC. I� N N 5n t 04 22 15 UPDATE TO 5TN ED. 20141 F&C JK VERTICAL CROSS SECTIONS r/i••!r(/ P'O. Box 234• Voirlco, FL 33595 tJ NO DATE BY Phone No.: 813.659.9197 REVISIONS FTBPE R.91,try No. 9813 • 02012 R.W.BUILDING CONSULTANTS INC. �0.; 'P •a X. on� 4" � �" I �� �VNi� * �•a Z� in 0� •, `` D III :o rtlilt� 4 y p N o � n v_ L7 O Z o &JAMBES III iYP.HEAD& — N o E m m o MASONRY MASONRY JAMBS a rn o a m DD.� N 8 LL m OPENING I I � N OPENINGo III L) Q � 'Z W c h1 z S '�a III b z 0 ^0 NZ W W 8 = FRAME — z L) o U MUWON III Fv z Z o zZ 2X BUCK SHOWN FOR ^O o rn KNy WV REFERENCE II a 3 m ONLY III N 2X BUCK w o o no C� zcn III F _ � < o c, Y U TYP.@ SILL F w a m o' m En � C U mUm U O f N�- n o00 N N N En z BUCKANCHORING HINGEJAMS FRAMEANCHORING SIRIKE JAMS S Masonry 2X buck construction `r' CONCRETEANCHORNOTES: 1.Concrete anchor locations at the comers may be adjusted to maintain the min. o o Q edge distance to mortarjoints. a 2.Concrete anchor locations noted as MAX.ON CENTER"must be adjusted to 0 0 0 amaintain the min.edge distance to mortarjoints,additional concrete anchors R may be required to ensure the MAX ON CENTER"dimension are not exceeded. 9_ 3. Concrete anchor table: 9 13 N g N F a is :JNIW CLEA0NCrF-WIN>CIE}IRiCNO LL :ANCHOR.ANLHOit;y ::.M11U€:2 ';...::.................................... :::...........;.......;..::........,,: �MBEDMLNT 70:MASONRY;.;.;,;:._70ADJACENT.:;.,. 10 ::::,:::.......:.... >i:'::i;;......::.`•:;>a::; •:::>.;•:::.. C TAPCON.......: ...: ...................................... ...............EDGE:::::.::::::.::::::.::.AN'HOR......... 11 scuE N.T.S.z D a ITW ® 1/4" 1-1/4" 2" 4" 13 ❑ DATE-02/16/12 zz DeWALT Dwc.BY: JK m' ULTRACON 1/4" 1-1/4" 1" 4" 27 cHw BY: LFS 3 WOOD SCREW INSTALLATION NOTES: DBAwwc No.: 1.Maintain a minimum 5/8"edge distance,I"end distance,8.1"o.c.spacing of HINGE DETAIL LATCH d DEADBOLTDEMIL FL-15213.15 =' wood screws to prevent the splitting of wood. a sHEEr 7 or 9 N V a �.�A.: n p Z �•�O` OOm ` O z° 10 H �4rr*r �� M o n o UN•• O Y v p 9 Z K TYP.HEAD& — 11 N E m m og o a 3 MASONRY IAMBS "' a N r m a a o OPENING r T 4 N E Vz EE w (� L 0 3d vl U TYP.@ FRAME _1 MUW IL ON HINGE DETAIL w oz coo �U �0 �o -0 r 2 to H J 0Z m U 1XBUCK h 28 W Zo wo a a O F. o I TYP.@ SILL F 13 a a _ D �m 1 f f 27 p C U U U ona N - a o00 N N N rn HINGEJAMB FRAMEANCHORING STRIKEJAMS LATCH&DEADBOITDETAIL w w w g Masonry 1X buck construction m FF� CONCRETE ANCHOR NOTES: 6 a1.Concrete anchor locations of the comers may be adjusted to maintain the min. o 0 0 $ - edge distance to mortarjoints.- - a 2.Concrete anchor locations noted as"MAX.ON CENTER"must be adjusted to a a a o maintain the min.edge distance to mortarjoints,additional concrete anchors may be required to ensure the MAX.ON CENTER"dimension are not exceeded. v N 0 3.Concrete anchor table; ^ N a F " :;;s;:+: ;;,:.y:,:::.;::.:,,•w /iNCHOR; 'ACOR:r:::•.;>r :. ...:.: TIN,.CIEARANGE.t.:.M...I.:N:..:C..L.:E:A.:'R...A.:NN GE..... `?iM :: . ... .... ..........::::s::.........,..................NH : y NYO.ADJACE¢fMM ::'iO:::;M-A..S. . t :.:;iii::Az Ei L ..M::-i . , .. .;.. G ;• : . . ....r. :. :.:...... o0 TTW cAT 02/16/12 i TAPCON® T/4" 1-1/4" 2" 4" srxLL- N.T.S. 9 m' DeWALT ® 1/4" 1-1/4" 1" 4" DWG.BY. JK ULTRACON64 mix.ar: LFS 3 WOOD SCREW INSTALLATION NOTES: muwNG NO•= n 1.Maintain a minimum 51W edge distance,1"end distance,B 1"o.c.spacing of FL—15213.15 n wood screws to prevent the splitting of wood. SHEET 8 or 9 BILL OF MATERIALS ITEM DESCRIPTION MATERIAL A 1 X BUCK SG>=0.55 WOOD B 2X BUCK SG>=0.55 WOOD '_•'g p <-i"' C 1/4 MAX.SHIM SPACE - 'V'c * �•��_r'a ro tA; z rc',3p` D 1/4"X 23/47PFH DeWALT OR RVN CONCRETE SCREW STEEL MASONRY-3,000 PSI MIN.CONCRETE CONFORMING TO ACI CONCRETE `�i 4S6" '�;� ` ~- E ....... ��` >>°0Z 301 OR HOLLOW BLOCK CONFORMING TO ASTM C90 I� % m F 1/4"X 23/4"PFH ITW CONCRETE SCREW STEEL I'll till i1 11 =C,1D H 1/4"x 3-IX PFH ITW CONCRETE SCREW STEELtF77 U o a I 1/4"X 2-1/4"PFH ITW CONCRETE SCREW STEEL o o v i m z°rc Em o J 1/4'X 33/4 PFH ITW CONCRETE SCREW STEEL m a mo I° K #10 X 2"PFH WOOD SCREW STEEL I--2.4,r L #8 X 2-1/7'PFH WOOD SCREW 1.15 MIN.EMBEDMENT STEEL E ;z° M #8 X 7'PFH WOOD SCREW STEEL DE 21 Pdyfibe SIDE lamb 9i`w 7 FORCE 5 WEATHER STRIPPING BY ENDURA FOAM a 8 COMPRESSION WEATHER STRIP QLON 650 BY SCHLEGEL FOAM 9 4"X 4"BUTT HINGE STEEL ?�„ 10 #9 X 1"PFH WOOD SCREW STEEL 4.56" --�i U o z 11 #9 X 314'PFH WOOD SCREW STEEL I o 13 #8 X 1-112"PFH WOOD SCREW STEEL o��„ ._ s 17 KWIKSET KEYED ENTRY-SIGNATURE SERIES STEEL 18 KWIKSETDEADBOLT-SIGNATURE SERIES(780 STEEL 7_ I - 5w N � 20 FINGER JOINTED PINE FRAME,HEAD 1L HINGE JAMBS WOOD i �—2 44• 2.13 4 o 21 POLYFIBER JAMB COMP./VINYL 27 LATCH STRIKE PLATE STEEL 'o m q' 28 DTADBOLT STRIKE PLATE STEEL 20 HEAD 3 SIDE a a 29 SIDELITE SPACER PVC 30 INSWING VINYL DOOR BOTTOM SWEEP BY ENDURA VINYL m 0 31 OUTSWING BUMP THRESHOLD ALUM. 5 63" 32 VINYL DOOR BOTTOM SWEEP#3628 BY HOLM IND. PVC I - F35 INSWING ADJUSTABLE THRESHOLD BY ENDURA ALUM./WOOD 4.56" INSWING ADJUSTABLE ALUMINUM THRESHOLD BY DLP ALUM./WOOD SHOE MOULD 5/8"X 3/8" WOOD m DOOR PANEL-SEE DOOR PANEL DETAIL SHEET FOR CONSTRUCTION DETAILS - W W W U) DOOR SKIN MIN.0.075'THIC FIBERGLASS TOP RAIL CELLULAR/PVCe LATCH&HINGE STILE �ZADJUSTABIf INSWING iHRESHO[D 34 ADJUSTABLE INSWING THRESHOLD CELLULAR/PVCw w 44 REINFORCEMENT WOOD FOR LOCKS(2(Y'LONG) WOOD a a a e 45 BOTTOM RAIL CELLULAR/PVC 3 e 46 POLYURETHANE FOAM BY NAN YA POLYURETHANE 4 69' 47 CONTINUOUS LATCH&HINGE STILE REINFORCEMENT WOOD N q N Q 49 GLAZING COMPOUND SILICONE ry o c 50 SIDELITE PANEL-SEE SIDEUTE PANEL DETAIL SHEET FOR CONSTRUCTION DETAILS SILICONE „a-z o° 8,z 51 SIDELITE TOP BOTTOM RAIL BY NAN YA CELLULAR/PVC a 55 UP LITE ODL/WESTERN REFLECTIONS HP POLYPROPYLENE —02 16112 i SCALE. N.T.S. 9 56 ALUM.GLAZING SPACER ALUM. 31 OUISWING BUMP iHRESHOID DM.BY: a 57 #8 x 1-1/2'PFH LITE FRAME SCREW STEEL CHw ar: LFS 3 DRAWING No- FL—15213.15 0 u SHEET 9 OF 9 rc t,-y, T �:O' plastpro 5200 W. CENTURY BLVD. y7 Z :0; q LOS ANGELES, CA 90045 '�.,�'•- - m o Smooth / Wood Grain/ White Wood Grain 74A"AAAX DVEItALLFRAMEWII�TH N e Em =m aIL N n g 9 OIL c W Rustic/Mahogany $ 4 M d`a 12 Series N Fiberglass Door i s= INSWING/OUTSWING $ a 'o "NON-IMPACT z�o AU N Z 3 zo o � GENERAL NOTES 5: L v, O 1. This product has been evaluated and is in compliance with the 7th Edition(2020)Ronda 3 Building Code(FBC)structural requirements excluding the"High Velocity Hurricane Zone" X S X c (HVHZ). a a a 2. Product anchors shall be as fisted and spaced as shown on details.,Anchor embedment to m base material shall be beyond wall dressing or stucco. p o 3. When used In areas requiring wind bome debris protection this product is required to be protected with an impact resistant covering that comprres with FBC Sections 1609.1.2& €� N R301.2.1.2. N ,n z 4. For 2x stud framing construction,anchoring of these units shall be the some as that shown for W En 2x buck masonry construction. 000 bL5. Site conditions that deviate from the details of this drawing require further engineering analysis 121, by a licensed engineer or registered architect. I�g 6 $ TABLE OF COMENrS SHEET DESCRIMON 1 Typical elevation,design pressures,&general notes 0 a .,"OVERALL'i.':.)``'s'''DOOR: t: :.r:;::1.:::.: ; E`IG" P,'E:..:,.,:•.E::.::;. n m 2 Door panel details ,GL:�4SS'.;�,S N,ftl;$$uR, (PSFJ, o 0 z al :,..:,:....,: nw— 3 Horizontal cross sections � z ;TYPE':::: z ;;>DIMENSfON_.`: DIMENSIONS;; :;>::' `tP�QSR'IVE:'. ;MEGATIVE'• DAM � 4 Vertical cross secikxs 02116112 s W 5 Buck and frame anchoring-2X buck masonry construction INSWING 74.0"x 82.0" 21.0"x 63.0" +47.0 47.0 N.T.S. 6 Frame anchoring-9X buck masonry construction G 1 BM BY. JK m 0 7 Endura astragal details OUTSWING 74.0"x 80.5' 21:0"x 63.0" +50.0 -50.0 Mr.BY. LFS 8 Bill of materials,"ng detail&components MWM No.: W. FL-15213.17 5 ° SHEET 1 OF 8 N o a R.\ClientskPlastpro,Inc PERMANENAA-Florida Product Approvals\FL-1 5213 Fiberglass Door-lns%ving-Outswing\C-Drawings\FL 15213(2020)\FL-1 5213.1 2.18.dwg,2.17 79.26'MAX.DOOR PANEL HEIGHT 63.9'MAX.D.L.O.HEIGHT T Po Pi b ta I B7Y--�-7 0.97" F1 p rn .... .... .... ........... z a 0 1.59" z iiiii ................. 0 > Q G) -CA 5;01 0 Z ZO M M 0 �> 0 < M m z ;o ;o L m z n m Iun pa tn 22 0 No. 09 August 5,2020 PRODUCT: ocauments PmPar"d Byer W, P.E. No Lyndon F. hmldt PLASTPRO INC. 4.3409 F7BERGLASS DOOR 3 -772-7/-20—UPDATE TO 7TH ED. (2020)FBC Al- r- c 10119117 UPDATE TO 6TH ED. Q017) FBG PART OR ASSEMBLY: BUILDING CONSULTANTS, INC. inn 1 04/22/15 UPDATE TO 5TH ED. (2014)FSC LS XU(P.O. Box 230, Voldc.. Fl.33595 I, DOOR PANEL DETAI NO. DATE BY Phone No.. 513.659.9197 REVISIONS FBPE Re tat No. 9813 201 2 R.W.BUILDING CONOULTANTB INC. Irk 4 4 EMB.(TYP.) Q.• t a 21 20 C A �Ok i * 1 a 4 2 4'n zIM &tp� Ems 18 ca 8 7 o o a m o rm 9 .w }^ 3 v 3 INTERIOR 00. 40 ® '�a rn m a I'L b , 4 X 3 X 4 g �z m 3 2w 17 y / / O / EXTERIOR 10 H z y 9 11 0 N a m U 11 D EWE 4 HORIZONTAL CROSS SECTION o o 3 4 3 Shownw/lxsub-buck o N o' EMB. MIP. 4 4 1TY ) -1/,'MIN. al 2 61 EMB.(TYP.) NOTE: m 1.As noted in the test report astragal was attached 0.1� C o C51NK to the inactive leaf with(10)#8 x T psh sms and CSINK o L r gyp.) (4)#10 x 2-1/2 pfh sms for all 6'-9'(outswing). (TYP.) L 9!T E2a a I Astragal was attached to the inactive leaf with 20 21 (9)#8 x T psh sms and(4)#10 x 2-1/2"pfh sms In21 20 $ for all 6'-8"(inswing). o 0 0 N N N y Z 4 8 7 8 8 7 R Do 40 INTERIOR 40 7 4() INTERIOR w a n O m a a f (( 10 EXTERIOR 1 SEE EXTERIOR 10 p smE* 16 12 0 M K N.T.S. 8 11 9 27 2 NOTE 1 9 11 8 MG.BY. JKCHIC.ft m s E 1 HORIZONTAL CROSS SECTION r2�HORIZONTAL CROSS SECTION ��HORIZONTAL CROSS SECTION E DRAWING NO.: LFS d 3 Outswing shown-insving 3 Outswing shown-inswing 3 Ouhwing shown-bowing FL-15213.17 N also approved ako approved also approved a SHEET 3 OF $ d V a2 ' R:1Cllents\Plastpro,Inc PERMANENT\A-Florida Ptoduct Approvals\FL-15213 Fiberglass Door-Inswing-Outswing\C-Drawings\FL 15213(2020)\FL-15213.12-16.dwg,4.17 WX MIN. EMB.(TYPJ rn v g M M22 g �' 4.w 22 46— O 22 • ° 0 30 O $Om 4_ 4 > ,a ro� atmn ° • C h 9wo :. a< 4 lV lV d C'SINK J e • ° M, (TYP.) P., 1.1/4"MIN. EMB.(TYP.) 1-1/4"MIN, EMS.(TYP.) m _ 0 •P ° • O 9 ..,fit M0 tl� Q O •. A 4► � cc�iYY�ii o p IM . n c0 .. v 0 Go V ., 1-1/4"MIN. EMB.(TYP.} m No.43409 August 5,2020 Q PRODUCT. Doourn-t.Pnpar.d By.••,,, O r Lyndon F. Schmidt ,N'.'•�DR1D�•'`• i N PLASTPRO INC. P.E. No. 43409 �fQfyAj,"1'�♦ } N y J 7 27 20 UPDATE 7Q 7TN ED. 2820 FEC' LFS F78 RGLAS DOOR '!lJJ/iiti111�� 2 10 19 17 UPDATE TO 6TH ED. 2017) FBC LFS pART OR ASSEMBLY; /C^ /�BUILDING CONSULTANTS, INC. y y x P, 1 04 22 15 UPDATE TO 5TH ED. 2014 FEC JK VERTICAL CROSS SECTIONS V 4MY P.O. Box 230, Valriao, FL 33595 14 tv NO. DATE BY Phone No.: 813.659.9197 REVISIONS FBPE Registry No. OS13 tD 2O1 2 R.W.SUILCINa CONSULTANTS INC. �- .% n 4-4 1 l � a %'1 Z * 1 fill � umm N \ O SEE DETAIL -•• co L, oil MASONRY TYP.HEAD MASONRYTYP.HEAD& ii E o0 OPENING &JAMBS OPENING JAMBS 9 a o L 7 _ II 4r m a a 2X BUCK—,, ASTRAGAL I I FRAME ASTRAGAL I i ¢u aZ SHOWN FOR I SHOWN FOR REFERENCE I I I b 2X BUCK REFONI YCE I o° a ONLY II 1 F ��" ' No s II ^° II U Z� SEE DETAIL III 1 TYP.@ SILL :T Z o o� '-O ci � II "1 �0 zo II Win} A� 28 a Yy M o' BUCKANCHORING HINGEJAMB FRAMEANCHORING ASMGALSMIKEJAMS a a minMasonry 2X buck construction ° ' aV31y LATCH&MADBOLTDETAIL N N N CONCRETEANCHORNOTES: ' ' Ep 2 1.Concrete anchor locations at the comers may be adjusted to maintain the min. N edge distance to mortar joints. e 2 Concrete anchor locations noted as MAX.ON CENTER"must be adjusted to DETAIL 2 9 o 0 maintain the min.edge distance to mortar joints,additional concrete anchors < may be required to ensure the MAX.ON CENTER"dimension ore not exceeded. K a a a d 8 3.Concrete anchor table: 3 »> 3 a ........ n N o `:ANCHQR3i !IN;;Cl.�4RA:NG_E.':M ..G1EARAENNSN O ADJACa....... Y%MBEDMET; M ... . ; ......... ...... ; EDGE. . . : ;::;•:::•;:: = :•:;;ANCHOR','::;::;: o o m ITW ® z Z TAPCON 1/4" 1-1/4 2" 4" n a^Z DAM 02 16 12 a DeWALT 1/4" 1.1/4" 1" 4" o W ULTRACONt 3 scus N.T.S. ITW N DWG.ar: JK m' ® 3/16" 1-1/4" 3" 1-1/2" HINGE DETAIL o TAPCON anc a LFS 3 WOOD SCREW INSTALLATION NOTES: DETAIL 1 DETAIL 1 WAMUG NO.: - 1.Maintain a minimum 5/8"ed a distance,1"end distance,&1"o.c.spacing of Inswing configuration Oulswing configuration N wood screws to prevent the splitting of wood. p F1-15213.17 N sir 5 or 8 d In z -MA 10 SEE DETAIL 11,1111 it% z ,o v a x=o N ! E Z m®¢ TYP.HEAD& I I N g o g 9 `o a JAMBS I I t a N"� an d to MASONRY HINGE DETAIL ? d OPENING I I E oz Q5 v ^ ' I � 3a hvC, ASTRAGAL 03z FRAME SHOWN FOR 28 mo II REFERENCE ONLY ��, mo O �� U .. 2:(Q cc En rtz Z 1_n m =U V1XBUCK I I ^0 27 a wo 0 �¢ F a � II 0 9 SEE DETAIL 1 TYP.®SILL a a "I" I I LATCH d DEADBOLTDETAIL j E? m `o G 000 .. . owe a o00 N Z HINGE JAMB FRAME ANCHORING ASTRAGAL STRIKE JAMB CC, w o Masonry 1 X buck construction � CONCREIE ANCHOR NOTES: 1O"� Cr 0 1.Concrete anchor locations at the comers may be adjusted to maintain the min. o 0 0 aedge distance to mortarjoints. _ _ 2 Concrete anchor locations noted as MAX ON CENTER"must be adjusted to 0 o Qo maintain the min.edge distance to mortar joints,additional concrete anchors DRAIL 2 >j may be required to ensure the MAX ON CENTER'dimension are not exceeded. o n a m v 3.Concrete anchor table: � $ n m N a LL :...:......:.:....... MIN: ANCy.QR`;ANCHOR, i.. ?::;::. TbMASONRY;:S4:i:IOAUJACENL o a :.:.:,. .. EMBEDMENT: : ::::;....-ri;,.SIZEz;i d:... :................. ........:. _o i ::.•::::.::..:::::::.:.::..::.._..:.:.EDGE;::;:rir:i:'. ::'':'ANCHOR>i:ii:`: 0 0 0 Z ITW 1/4" 1-1/4" z o TAPCON -w--0217 6112 i w DeWALT ® 1/4" 1-1/4" 3 owc By: N ULTRACON+ g TAITW 0 3/16" 1-1/4" 3" 1-1/2" N Cwc rr: LFS 3 INSTALLATION NOTES: ow�wixc NO.: WOOD SCREW DETAIL 1 DETAIL 1 w as 1.Maintain a minimum 5/8"edge distance,1"end distance,&1"o.c.spactrg of Inswing Configuration Outswing configuration FL-15213.7 7 a wood screws to prevent the splitting of wood. sNcrr 6 or 0 ct R,.\CIients\PIIUtprc,Inc PERMANENT\A-Florida Product Approvals\FL-15213 Fiberglass Door-lnswing-Outswlng\C-Dmmdnqs\FL 15213(2020)\FL-15213,12-18.dwg,7.17 C= 65 m ro I z C= M ;v - 0 C" > z m 0 —2.6.7 z :n Oq CD 0SX TOP a 0 U m q C; R > z V z >0 0 > 0 Or '01 BOTTOM Lq ow C "S ......... No.43499 J IT August 5,2020 PRODUCT: ttooumente Prepared Op-1W, -W-- o PLASTPRO INC. Kdon F. SC A40"N .......... No. 43409 A. FIBERGLASS DOOR ;hmtdt jog" 0 UPDATE TO 7TH ED, (2020)FBC —Lff I 1 0 !LPDAIC TFO po r'! '0 LFS PART OR ASSEMBLY: 1 4 22 15 C BUILDING CONSULTANTS. INC. In�� Up.. T.', " !P a- -TK- P.O. Box 230.VaIrloo, FL 33593 Do A . -- '. (201 FBC j I ;� NO NDATE BY ASTRAGAL DETAILS Phone No.: 813.859.9107 14 REVISIONS (ULTIMATE HURRICANE) 18PE Registry No. 9813 02012 R.W.BUILDING CQUISULTANT5$Nfl, BILL OF MATERIALS REM DESCRIPTION MATERIAL ITEM DESCRIPTION MATERIAL �' A 1X BUCK SG>=0.55 WOOD 20 FINGER JOINTED PINE FRAME,HEAD&HINGE JAMBS WOOD B 2X BUCK SG>=0.55 WOOD 21 POLYFIBER JAMB COMP./VINYL C 1/4"MAX.SHIM SPACE - 27 LATCH STRIKE PLATE STEEL D 1/4"X 2-3/4"PFH DeWALT OR ITW CONCRETE SCREW STEEL 28 DEADBOLT STRIKE PLATE STEEL '.�• Z. ra s 6 30 in E 301SONRY-OR HOLLOW BLOCK CONFORMING PSI MIN. TOO ASTM CONFORMING TO ACI CONCRETE 31 OUTSWING BUMP O 6�7 HOLM INDUSTRIES ALUM./WOOD�ANYL '''��'///•*• •1 1 `` o n°`O Z 11 111 p t4 F 1/4"X 2-3/4"PFH ITW CONCRETE SCREW STEEL 32 VINYL DOOR BOTTOM SWEEP#3628 BY HOLM IND. PVC ° q y a O o Z G 3/16"X 3-1/4"PFH ITW CONCRETE SCREW STEEL 33 INSWING ADJUSTABLE THRESHOLD BY ENDURA ALUM./WOOD ` i m Z a,cm @ w H 1 XX 3-1/4"PFH ITW CONCRETE SCREW STEEL 34 INSWING ADJUSTABLE ALUMINUM THRESHOLD BY DLP ALUM./WOOD t u a 5 c m I 1/4"X 2-1/4"PFH ITW CONCRETE SCREW STEEL 40 DOOR PANEL-SEE DOOR PANEL DETAIL SHEET FOR CONSTRUCTION DETAILS "� m d a J 1/4"X 3-3/4"PFH FFW CONCRETE SCREW STEEL 41 DOOR SKIN MIN.0.075"THICK) FIBERGLASS c o K #9X 2-1/2"PFH WOOD SCREW STEEL 42 TOP RAIL CELLULAR PVC Q oZ L #10 X 2-1/2"PFH WOOD SCREW 1.15"MIN.EMBEDMENT STEEL 43 LATCH&HINGE STILE CELLULAR PVC M #9 X 2-1/4"PFH WOOD SCREW STEEL 44 LOCK REINFORCEMENT WOOD o N 3/16"X 3-1 IT PFH ITW CONCRETE SCREW STEEL 45 BOTTOM RAIL CELLULAR PVC z c O 3/16 X 1-1/2'PFH ITW CONCRETE SCREW STEEL 46 POLYURETHANE FOAM BY NAN YA POLYURETHANE Q: W 1 #10 X 2-1/2'PFH SMS STEEL 47 CONTINUOUS LATCH&HINGE STILE REINFORCEMENT WOOD z o "o 2 #8 X 3"PSH SMS STEEL 49 GLAZING COMPOUND DOW 995 SILICONE a 3 FLUSH BOLT STRIKE PLATE STEEL 55 UP LITE ODL/WESTERN REFLECTIONS HP POLYPROPYLENE a 5 7 Q-LON 650 WEATHER STRIP SCHLEGEL FOAM 56 ALUM.GLAZING SPACER ALUM. 'U m 8 COMPRESSION WEATHER STRIP QLON 650 BY SCHLEGEL FOAM 57 #8 X 1-1/2'PFH LITE FRAME SCREW STEEL a m L- 9 4"X 4"BUTT HINGE STEEL 61 BOLT RETAINER NYLON � o o 10 #9 X I"PFH WOOD SCREW STEEL 65 ASTRAGAL BY ENDURA PRODUCTS ALUMINUM of m 0 11 #9 X 3/4"PFH WOOD SCREW STEEL 67 SLIDE BOLT ROD STEEL 17 KWIKSET KEYED ENTRY-SIGNATURE SERIES STEEL 12 a a 18 KWIKSEf DEADBOLT-SIGNATURESERIES 780 STEEL 'm 4.69' S6 4 4 4 I h N^ N N N N h Z W W w O Cn f�244" 2.13" �i 3i OUFSWING BUMP THRESHOLD 0 2 2 a 20 HEAD d SIDE N I,-w Jamb 8 N 4S6" = v' I _ I 4.56"�� n w^z [°i _ m I I �h 02/16 12 i a 2.44" SCALE N.T.S. 9 •By HEAD d SIDE 21 cm BY. LFS 3 a 33 ADJUSTAELEINSWINGTHRESHOID ADJUSiABlE1NSWINGTHRESHOLD P°IyfiberJ°mb MAWNG NO.. n FL-15213.17 o SHEET 8 OF $ N V G %%%%% plastpro � . �..5200 W. CENTURY BLVD. - > Zo LOS ANGELES, CA 90045 `•... .• ' �`� F37S MAX.OA N>-z FRAME WIDTH � �i�� �c ���� z oN m rrrrrl 111�� $ •:'� v z o nZO W 9mCz� Smooth/ Wood Grain /White Wood Grain a 21 p�0 t Rustic/Mahogany � m 4 a cq Series Fiberglass Door 9= INSWING/OUTSWING s a 'IMPACT" Z Z A m z 00 o wow rs � zo zw (� o� �w � J ¢C7 GENERAL NOTES - ^ 1. This product has been evaluated and is in compliance with the 7th Edition o o of n (2D20)Florida Building Code(FBC)structural requirements excluding the"High X c 1]2 a Velocity Hurricane Zone"(HVHZ) I g a o 2. Product anchors shall be as fisted and spaced as shown on details.Anchor m o m a0 embedment to base material shag be beyond wall dressing or stucco. IEJE 3. When used in areas requiring wind bome debris protection this product R complies with FBC Sections 1609.1.2&R301.2.1.2 and does not require an R NEn N M impact resistant covering.This product meets missile.level"D"and includes Wind z Zone 4 as defined in ASTM E1996 and.FBC Sections 1609.1.2.2&R3012.1.21. 4. For 2x stud framing construction,anchoring of these units shall be the some as b that shown for 2x buck masonry construction. o o a o00 5. Site conditions that deviate from the details of this drawing require further engineering analysis by a licensed engineernr registered architect. ° O IV^H Q F TABLE OF CONfEtO z SHEETS DFSCRIPflON = -_ _-_ _-_ ___ _. _ .._ .-- .- -- "'"'-z a° DES/GN PRESSURE. _S ° a 1 Typical elevation,design pressures.&general notes .__. — - DATE 02/16/12 z ,.SWING ==; _-___=:FRAiItE"n `'. -_:�:----------- Door - 2 panel detals =_--_ __= -' _ - ° 3 Hor¢ontalarosssections _ _= _ _=__ = -bENSION P03R1YE'?:NEGA7i1!E_ � N.T.S. d - M.er. JK m 4 Vertical cross sectioru INSWING 37.5'x 82.0" +65.0 -70.0 a,K er: LFS 3 a 5 Buck and frame anchoring-2X,buck masonry construction O(L1N7NC NO.: R g 6 Frame anchoring-IX buck masonry corction OUTSWING 37.5"x80.37" +65.0 -65.0 FL-15213.1 n utru 7 Bill of materials&components sNccr 1 of 7 u a R:\Cllents\Plastpro,Inc PERMANENT\N-Florida Product Approvals\FL-15213 Fiberglass Door-Inswing-0utswing\C•Drawings\FL 15213(2020)\FL-15213.1-.8.dwg,2.1 79.25"MAX.DOOR PANEL HEIGHT tv LLJ N n g ¢ppp �C P30t~'3 A cr X NN �O 4 .o N --i 1.2T �-- o R-T M1 �,/�a 7t7 7tT N 0 �z ��•--•1.58" —�� �� s� 1 t�1.52' 3� 1s a 1C�'s •C1 O A O N to Z 'O O No,43409 4AUgust5,2020 o n Q PRODUCT: Doeummto Papand ey:rf ,• `� F1. Lyndon F. Schmidt �✓j ••• AXORID�:•••�``�� PLASTPRO INC. P.E. No. 43409 [NO, 7 27 20 UPDATE TO 7TH ED. 2020 FBC LFS FIBERGLASS DOOR DLf0 19 17 UPDATE TO 6TH ED. 2017 FBCLFS PART OR ASSEMBLY: r BUILDING CONSULTANTS, INC. Z !A\ 4 22 15 UPDATE TO 5TH ED. 2014) FBC JK DOOR PANEL DETAILS UY P•0• Boz 230, Valrleo, FL 33899 tvDATE BY Phone No.: 813.659.9197 REVISIONS I FBPE Registry No. 9813 0 2012 R.W.BUILCINC CCNeULTANT9 INC. R:\Clients\Plastpro,Inc PERMANEN'M-Florida Product Approvals\FL-15213 Fiberglass Door-Inswing-Outswing\C-Drawings\FL 15213(2020)\FL-15213.1-.8.dwg,3.1 m- �A 3z W N oO O W N c O 7e go O p e m o• t0 N e N � O• (�� •Q a d: ' `� N `�� z ,p � o W W N N mZ w A Cc) Co s 3? M O 70 M X j N ° 09� a a CD w n•� y A m O z 5 Lo 7 O O W W W N ���777777 Q A W 0 W� C O• o. N 3y0 L•X� Q o3OS 0 3 � W_. V pa f�D 0 S V P gy 7ne A W l0 H N m W Cn Z p 1111111111/�� 1F No.43409 August 5,2020 S2 q g Q PRODUCT: Document.P.Pond ey:1,F� ..... �. . r7, Lyndon F. Schmidt , ..... IW 2 DOOR r ro 3 7 7 20 UPDATE i0 7TH ED. 2020 FBC IFS FLAS �S� C. P.E. No. 43409 �j�7��� A`lt `�\� r N `' •—Zf 2 10 19 17 UPDATE 70 6TH ED. 2017 FBC LFS PART OR ASSEMBLY: /t- BUILDING CONSULTANTS, INC. 1 4 22 15 UPDATE TO STH ED. 2014) FBC J!C J l��P.O. Box 230, Valrico, FL 33595 to HORIZONTAL CROSS SECTIONS n� NO DATE BY Phone No.: 813.659.9197 REVISIONS FBPE Registry No. 9813 0 2012 R.W.BUILDING CONSULTANTa IND. _ R.NCllents\Plastpro,Inc PERMANENTVk-Florida Product Approvals\FL-15213 Fiberglass Door-Inw4ng•Outswing\C-Drawings\FL 15213(2020)\FL-15213.1•.BAwg,4.1 g g A W 70 A y 222 .. .p ; 01 oarO-:z ' F O CL s 4'. M s O. A ° ° 4 •� ♦ W l a ° 4 0.151, ° ° C SINK L A, (TYP.) a 4 P. 1-1/4"MIN. EMB.(TYP.) gn to v Ara M $ N AA ,,n ° x I" n. 7 r'o n Sri n 0 �n 22 C1 °. C ° 0 1-1/4"MIN. EMB.(TYP.J ``��\111111t111 ' F•SCH%, .,,. z� No.43409 August 5,2020 Q PRODUCT: Document. Prepona Eyw•„r `� 1' t� Lyndon F. Schmidt / R4......•• �� E PtASTPRO INC. P.E. No. 43409 3 7 27 20 UPDATE TO 7TH ED. 2020 F8C [LIF. FIBERCLASS DOOR j*44 11110% o "0., � y rn 2 10 19 17 UPDATE TO 6TH ED. 2017 FBC LFS PART OR ASSEMBLY: ems- / BUILDING CONSULTANTS, INC. W (4\ 1 04 22 15 UPDATE TO 57H ED. 2014 FBC JK VERTICAL CROSS SECTIONS sl l• P•0. Box 230, Valrlco, FL 33595 V N NO DATE $Y Phone No.. 813.659.9197 REVISIONS FBPE Registry No. 9813 �.20r2 R.W.BIIILaINa 00NBDLTANTB IND. i�• • �OIm 1 >• �omo ••-•••• •• ` N' Z C m — 5 E Oov t, 0 Z o Ea z o¢ TYP.HEAD&JAMBS "' m m a a 2x7 BUCK E oz a _TYP.HEAD& 2X JAMBS o BUCK 11= � F" z~ FRAME h z o zo ¢o O� •• W � � w a5 m �z MASONRY MASONRY OPENING •o Z OPENING U CL a vs m �O _ z0 9 Yx a jj 0 mm O o o N o U mUm U !d ' O O O _ N N N � z BUCKANCHORING HINGEJAMB FRAMEANCHORING STRIKEJAMS w w 0 Masonry 2X buck construction i--ir-4 CONCRETE ANCHOR NOTES: ^ >, 1.Concrete anchor locations at the comers maybe adusted to maintain The min. o 0 0 a edge 'stance To morfarjoirifs. n 2.Concrete anchor locations noted as MAX.ON CENTER"must be adjusted to a a a o o maintain the min.edge distance to mortar joints,additional concrete anchors 21 13 >>> b may be required to ensure The MAX.ON CENTER"dimension are not exceeded. 6 It O 26 N W a 3.Concrete anchor fable: a N!R i LL ::_;::;:;:.:=<:;: •:x.;:;.:::.:;;;::::•:::•:'e;::::::.::::::::.:: ;; futlNCLEARANCt;:;MIN+>CLEARANCE N N ao 1 4NC'NOR:.'A:NCHOR,; ;i i :::.;.::•:.......................................................................... .o a o :.::.:::....:.::.::,..:. ::.,:;...:::-::;•;;:;: .....,.........,:._.,....:i:::::70MASONRY,..:: y:;LOA:DIAGENL',{ g 27 o n '::SIZE;isi EMBEIIDMWT:: is :..::..::;;::;;t.:-r:;.::t>:::::: :. ri EDGE:..:.:::::.::.: z D a ......... ....... .::..............................._.......ITW osh 02/16/12 i f o 1/4" 1-1/4' 2" 4" n "c TAPCON sruc• N.T.S. •+ DeWALT M.BY. JK o' ULTRACON4 1/4" 1-1/� 1" 4" HINGEJAMB STRIKE PLATE DETAIL CM ErY` LFS 3 WOOD SCREW INSTALLATION NOTES: DRAWNG NO, � 1.Maintain a minimum S/6"edge distance,I"end distance,&i"o.c.spacing of FL-15213.1 " wood screws to prevent the spgfing of wood. °ro V SHEET S OF 7 C °s. f iw�'• ••gZl�.. �o m o n /JJJtfil{ tit��', ti n..n :o 0 •o 30 - - - - - i ozr0 TYP.HEAD& _ N E�`vn< 9 cis a n. JAMBS 4 m a a 1X OE `0z BUCK �a �O z P FRAME zo =� LL V)i5 m az MASONRY- 2W �w N �� OPENING ^z ° o o $ co a � k o LU n Z HINGE JAMB FRAMEANCHORING STRIKE JAMB w w w o Masonry 1X buck construction v CONCREl-ANCHOR NOTES., m a t.Concrete onchortocaltons at the comers may be adjusted to maintain the min. o 0 2 S edge distance to mortarjoints. o o a 2.Concrete anchor locations noted as"MAX.ON CEMEW must be adjusted to maintain the min.edge distance to modar joints,additional concrete anchors >> emay be required to ensure the"MAX.ON CEMER'durtension are not exceeded. 21 a 3.Concrete anchor table: a :..... ::-::.: ::::.: .. .. MIN:<:CtEARANCE :'MIN CLEARANGE 31 26 � N W n O,N H arvcHOR ,dNcroa;>::>;.::n+rn�:';>i;;s. ....... . N •-N d µ TO:141i9YOMRY¢:= 'Ap7ACENF:;; � 7YPfi r EMSEDME1i[F: >_' v o :.-:.:..::.::....`- :e.:ra;:::;>::.:.:::.......,.........."..EDGE:;&:::r::: ;;;:eANCHOR:;:::;-:: 2T Z n N^z a° z 33 TAPC NO 1/4• 1-1/4" r 4' DATE O2 16 72 c 2 DeWALT 1/4' 1-114, r I scuE N.T.S. a llLTRACON � UY; JIC m c ITW ® 3/16' 1-1/4" 3' 1-11r CHc Hy; LFS 3 g TAPCON HINGEJAMB SMIX PLATE DETAR �wc,o": rc „' WOOD SCREW INSTALLATIONNO7ES: ro i,Maintotn o minimum 5/8"edge distance,t"end distance,&i'o.c.spacing of FL—t 5273.} n e wood screws to prevent the spritting of wood. sHtar 6 or 7 n v c BILL OF MATERIALS A, 0��• ITEM DESCRIPTION MATERIAL g MASONRY-3,000 PSI MIN.CONCRETE CONFORMING TO ACI 1 301 OR HOLLOW BLOCK CONFORMING TO ASTM C90 CONCRETE . 2 1XBUCKSGy=-0.55 WOOD %V.; Z �jQ� 4 2X BUMAX HIM SPACE WOOD ',//rlrr �` ;`����` wZ> z 5 1/4"X 2-3X PFH DeWALT OR TTW CONCRETE SCREW STEEL O N.. 6 #10 x 2-1/2"PFH WOOD SCREW 1.15"MIN.EMBEDMENT) STEEL o v Z o Z 8 #9 x 3/4"PFH WOOD SCREW STEEL 4j r rn N r W 9 m c w 9 DOOR SKIN MIN.0.075'THICK FIBERGLASS 4.56' �^ 4S6" "' va 7 'm 4a`a 10 INSWING VINYL DOOR BOTTOM SWEEP BY ENDURA VINYL I 4 10A VINYL DOOR BOTTOM SWEEP#3628 BY HOLM IND. VINYL 7 E `o z 11 REINFORCEMENT WOOD FOR LOCK WOOD '3�c wa 12 FINGER JOINTED PINE JAMB WOOD [tj�13 #9 x 2-1/4"Pfli WOOD SCREW STEEL �2-12917 �2.12T � 0 14 BOTTOM RAIL CELLULAR PVC I_ 15 INSWING ADJUSTABLE THRESHOLD BY ENDURA ALUM./WOOD 243" 243' o JN 15A INSWING ADJUSTABLE ALUMINUM THRESHOLD BY DLP ALUM./WOOD (3o ww 16 FORCE 5 WEATHER STRIPPING BY ENDURA FOAM 1Y JAMB POLYFlBERJAMB 16A COMPRESSION WEATHER STRIP QLON 650 BY SCHLEGEL FOAM a w U-ME 17 KWIKSEFKEYEDENTRY-SIGNATURESERIES STEEL ��N 00 18 KWIKSETDEADBOLT-SIGNATURE SERIES 780 STEEL am_< �QY 20 POLYURETHANE FOAM BY NANYA POLYURETHANE �I o m K 21 4"x C BUTT HINGE STEEL g 0 23 POLY FIBER JAMB COMP./VINYL m a 24 HINGE 8.LATCH STILE CELLULAR PVC - H r 25 TOP RAIL CELLULAR PVC 4.58' m 4.56" a r3O DEADBOLT STRIKE PLATE STEEL LATCH STRIKE PLATE STEEL r OUTSWING BUMP THRESHOLD ALUM./WOOD R a HINGE✓£LATCH STILE REINFORCEMENT LVL o 0 0 1/4"X 3-3/4"PFH ITW CONCRETE SCREW STEEL N`Nz#9 x 1"PFH WOOD SCREW STEEL 1/4'x 3-1/4"PFH ITW CONCRETE SCREW STEEL �1ApJU5iA8[EINSWINGSILL OIRSWINGBUMPTHRESHOID 33 3/16"X3.1/4"PFH ITW CONCRETE SCREW STEEL 2B o00 40 DOOR PANEL-SEE DOOR PANEL DETAIL SHEET FOR CONSTRUCTION DETAILS 2 o00 aaa ti n> z o^ zq N^ w z O 5.6T N�Np 7 ^O O q z Z nNZ Ll a ah 02116 12 12 SCALE. N.T.S. S DWG.a1: JK m c cw_BY: LFS 3 15 ADJUSTABLE INSWING SILL DRIWNG N0: FL-15213.1 u SNP 7 or 7 V a