Loading...
HomeMy WebLinkAbout20-923 ` a _ _ City p Y of Ze h rhills PERMIT NUMBER 5335 Eighth Street Zephyrhills, FL 33542 BNR-000923-2020 Phone: (813)780-0020 ffra, Fax: (813)780-0021 Issue Date: 11/24/2020 A Permit Type: Building New (Residential) �'' Property Number Str et Address � .H = - - 04 26 210120 00000 0590 6423 Bradford Woods Drive Owner Information "": r Permit Information Contractor�lnfocmation Name: PULTE HOME COMPANY LLC Permit Type:Building New(Residential) Contractor: PULTE HOME COMPANY Class of Work:SFR'Construct LLC Address: 2662 Falkenburg S Rd Building Valuation:$154,859.00 RIVERVIEW,FL 33578 Electrical Valuation:$7,325.00 Phone: (813)964-5182 Mechanical Valuation:$6,640.00 Plumbing Valuation:$6,087.00 Total Valuation:$174,911.00 nt& Total Fees:$14,351.03 Amount Paid:$14,351.03 Date Paid:11/24/2020 8:54:45AM Project Description _ CONSTRUCT SINGLE FAMILY 3,670 Application Flees Plumbing Plan Review Fee $35.22 Building Permit Fee $804.30 SIF 1 percent Fee $83.28 Electrical Permit Fee $76.62 3/4 Water Meter Fee(Calc) $473.78 Plumbing Permit Fee $70.44 Mechanical Permit Fee $73.20 Address Fee $30.00 Electrical Plan Review Fee $38.31 Sewer Connection Residential Fee $2,090.00 Public Safety Impact Fee-Admin $26.35 Driveway Fee $45.00 Building Plan Review Fee $402.15 Water Connection Residential Fee $1,010.00 Irrigation 314 Meter(Calc) $473.78 School Impact Fee $8,328.00 Mechanical Plan Review Fee $36.60 Public Safety Impact Fee-Police $254.00 REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each subsequent reinspection. Notice: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permit required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner:Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications add fee Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. ON CT SIGNATURE PE IT OFFICE PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER y Ayr /3 7X- INSTR#2020173419 OR BK 10197 PG 2643 Page 1 of 1 10/15/2020 03:16 PM Rcpt:2215853 Rec:10.00 DS:0.00 IT:0.00 Nikki AlvarezSowles,Esq.,Pasco County Clerk&Comptroller Permit No. PerceIIDNo 04-26-21-0120-00000-0590 NOTICE OF COMMENCEMENT state of Florida county of Pasco THE UNDERSIGNED hereby gives notice that Improvement will be made to certain real property,and In accordance with Chapter 713.Florida Statutes• the following Information is provided in this Notice of Commencement 1. Description of Property,Parcel Identification No. LOT o590 BLK 01 streetAdaress: 6423 Bradford Woods Drive.Zephyrhi ls,FL,33542 Oaks of Pasco 2 General Description of Improvement_ New Construction-Single Family 3. Owner Information or Lessee Information ifthe Lessee contracted for the Improvement Pulte Home Company,LLC 2662 S.FalkenReM Road Riverview FL Address city Is Interest In Property: Fee Simple Name of Fee Simple Titleholder, (If different from Owner gated above) ress 4. Contractor. Pulte Home Company,LLC city smle 2662�.Taalkenburg Road Riverview FL Address city State Contractor's Telephone No.: 813-964-5115 5. Surely: N/A Name Address City state AmountofSond:S TelaphoneNo.: S. Lender. 1;1A Name Address city, state Lenders Telephone No.: 7. Persons within the State of Florida designated by the owner upon whom notices or other documents may be served as provided by Section 713.13(1)(a)(7),Florida Statutes: N/A Name Address City State Telephone Number of Designated Person: S. In addition to himself,the owner designates NIA of_ to receive a copy of the Llenors Notice as provided In Section 713.13(1)(b),Florida Statutes. Telephone Number of Person or Entity Designated by Owner. g. Expiration date of Notice of Commencement(the expiration data may riot be before the completion of construction and gnat payment to the contractor,but will be one year from the data of recording unless a different date is specified): WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT RESU 7tINlYOURIMPROPER AYING T ICE FOR IMPROVEMENTS UNDER O YOUR PROPER Y. A NOTICE' FLORIDAFCM NCEMERt MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING.CONSULT WITH YOUR LENDER GRAN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. Under penalty of perjury,I declare that 1 have reed the foregoing notice of commencement and that the facts state reins tr re to the best of my knowledge and belief. STATE OF FLORIDA �+ COUNTY OFPASCO Signal of r Lessee,or or Lessee's Aulhor'¢ed tbdor/PartnerlManager Division VP of Finance Signora"TalerOfgcs The foregoing instrument was acknowledged before me this 1_5 day of October 202Qby Matthew Hurd as Attorney In Fact (�a of ulhority,e.g.,officer•trustee.attorney In fad)for Pulte Home Compally.LLC (name oly behaVofYhomlI{r{ryypp,uu,mmentw'asexeee}utted). Personally Knawn®2E Produced Identification❑ Notary Signature IZ.GG(. Type of Identification Produced Name(Print) PaUtcia BurdneU PA1RIlaA gUBCSETT HYCOMMI0174133MIT1 BPgIW.001S,2MMS IiodeEf000Pt Imsote Yrartras INVOICE • • FOR CITY OF ZEPHYRHILLS BILLING CONTACT f 9 JODY SALTER PULTE HOME COMPANY LLC 2662 FALKENBURG S RD RIVERVIEW, FL 33578 INVOICE NUMBER INVOICE DATE INVOICE DUE DATE INVOICE STATUS INVOICE DESCRIPTION INV-00001826 11/05/2020 11/05/2020 Due NONE REFERENCE NUMBER FEE NAME TOTAL BNR-000923-2020 3/4 Water Meter Fee(Calc) $473.78 Address Fee $30.00 Building Permit Fee + 6 , `� $804.30 Building Plan Review Fee l `1 $402.15 Driveway Fee $45.00 Electrical Permit Fee IrC4-q3 $76.62 Electrical Plan Review Fee $38.31 Irrigation 3/4 Meter(Calc) $473.78 Mechanical Permit Fee (09, 60 $73.20 Mechanical Plan Review Fee $36.60 Plumbing Permit Fee l �(� $70.44 Plumbing Plan Review Fee $35.22 Public Safety Impact Fee-Admin $26.35 Public Safety Impact Fee-Police $254.00 School Impact Fee $8,328.00 Sewer Connection Residential Fee $2,090.00 SIF 1 percent Fee $83.28 . Water.Connection Residential Fee $1,010.00 6423 Bradford Woods Drive Zephyrhills, FLORIDA 33542 SUB TOTAL $14,351.03 REMITTANCE INFORMATION TOTAL $14,351.03 City of Zephyrhills 5335 8th Street Zephyrhills, FL 33542 --t4j-5 49 November 05,2020 5335 8th Street,Zephyrhills,FL 33542 Page 1 of 1 Viiy vi" _wpi Iyi i imo rri I I IR r'1LJVin cIuVl 1_ r an-u w-r w-vu�r Building Department )ate:ReceivedLO� ) of Phone Contact for Permitting /3 )wner's.Name PL4_1 k C "I o m t Cv P A( t. (-LC-, Owner Phone Number ).wner's Address 2lrlr 2 S, Fa lien bUr� 0/. ilvad l2j t] L Owner Phone Number 'ee Simple"Titieholder Name !� Owner Phone Number °ee Simple Titleholder Address, i08 ADDRESSZoe ( LOT# iUBDIVISION DW��D SSG'D PARCEL ID# (OBTAINED FROM PROPERTY TAX NOTICE) NORK PROPOSED. NEW CONSTR ADD/ALT SIGN Q Q DEMOLISH Pq INSTALL R REPAIR )ROPOSED USE FX_J SFR Q COMM OTHER TYPE OF CONSTRUCTION BLOCK 0 FRAME STEEL Q )ESCRIPTION.OF WORK. IZ:NJ WILDING SIZE �� SQ FOOTAGE HEIGHT Q BUILDING $ VALUATION OF TOTAL CONSTRUCTION QELECTRICAL $ 17 g AMP SERVICE Q PROGRESS ENERGY Q W.R.E.C." =PLUMBING =MECHANICAL VALUATION OF MECHANICAL INSTALLATION. =GAS Q ROOFING 0 SPECIALTY Q OTHER =INISHED FLOOR ELEVATIONS / / FLOOD ZONE AREA =YES NO 3UILDER COMPANY SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address A5; 4� ,t141e4 W1R-,339VJLicens'e # NX. � LECTRICIAN COMPANY 5 T ad w !/� 316NATURE REGISTERED Y/ N_J FEE CURREN Address ! / L License.# E� 3?�5 PLUMBER J COMPANY �J� / �✓'�/ SIGNATURE ,,/ �i�, // ' f ,,,// REGISTERED Y/ N FEE CURREN Address: 3!33/I/� 37 (j�/r�Gbu v�.1��L31,�785' License#: l ya�a�:-7 MECHANICAL COMPANY =/W/7 '/f/'t 6)W/hAit�6 f'I SIGNATURE' REGISTERED Y/ N FEE CURREN R/3 ne,1 �� ash►,FL 3Cl ,&-7 : Address License# OTHER- COMPANY SIGNATURE REGISTERED Y/ N" FEE CURREN Address; - "l gel�/7/!;? A) W D/?` iGh 1 FLI 3 License# RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, " Minimum ten.(10)working days after submittal date."Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, " Sanitary Facilities&1 dumpster,Site Work Permit for subdivisions/large projects COMMERCIAL Attach(2)complete sets:of Building Plans.plus a Life:Safety Page;(1)set of Energy Foims:R-O-W Permit=for new construction: Minimum ten(10)working days after"submittal date. Required onsitee,Construction Plans;Stormwater Plans w/Silt Fence installed, Sanitary Facilities,&1 dumpster.Site Work Permit for all new projects._All commercial requirements must meet compliance SIGN PERMIT:. Attach.(2)sets of Engineered Plans. ****PROPERTY SURVEY required for all NEW Construction. Directions: Fill.out application completely. Owner&Contractor sign back of application,notarized If over$2500,a Notice of Commencement is required. (A!C upgrades over:$7500) "* Agent(for the contractor)or-Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage) Driveways-Not over Counter if on:public roadways..needs ROW r' oiriov-uuty L;lty OT.LepTlyrnuis h'ermit.Application rax-ti73-R3U-UU17' Building:Department. Date Received Phone Contact for Permitting aaa.aaaia IN it aaaaa Owner`s Name kl 6 gy Owner Phone Number Owner's.Address ? l '. j L Owner Phone Number Fee Simple:Titleholder Name Owner Phone Number Fee Simple Titleholder Address412A JOB ADDRESS J ©� [ ... /�Il�� � LOT SUBDIVISION PARCEL'ID# Gr 4'a?(0r 1"01® l/+U04Jo (o5qo (OBTAINED-FROM PROPERTY TAX NOTICE): WORK PROPOSED NEW e CONSTR ADD/ALT u SIGN Q_ Q DEMOLISH- INSTALL 8 REPAIR PROPOSED USE SFR Q COMM [s r OTHER TYPE:OF CONSTRUCTION. BLOCK Q FRAME STEEL Q DESCRIPTION OF WORK :BUILDING.SIZE �(//` ! SQ FOOTAGE[/y� HEIGHT - € +€� =BUILDING $ / � P /, VALUATION OF TOTAL CONSTRUCTION [ELECTRICAL $ 0 7` AMP SERVICE 0 PROGRESS ENERGY Q W.R.E.C. PLUMBING rs� 0 =MECHANICAL 1$ VALUATION OF MECHANICAL INSTALLATION =GAS Q ; ROOFING. 0 SPECIALTY OTHER FINISHED FLOOR ELEVATIONS q1, p FLOOD ZONE AREA =YES :NO BUILDER COMPANY ,S SIGNATURE REGISTERED Y/N FEE CURREN Y/N Address' , License# :ELECTRICIAN COMPANY SIGNATURE REGISTERED Y/N FEE CURREN Y-/N Address License# PLUMBER COMPANY SIGNATURE REGISTERED Y I N FEE CURREN Y/N Address License# MECHANICAL COMPANY SIGNATURE REGISTERED Y/N FEE CURREN Address . License# F- OTHER COMPANY 0=§1� � SIGNATURE REGISTERED Y/N FEE CURREN Address �, License# IIt-2.11tt1alt.Val aaati:ItZ 11 flags Ra [Itaga & I€IF:astaltllf:IEltltaIitall . ... RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction; Minimum ten(10)working days after submittal date.Required.onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster,Site Work Permit for subdivisions/large projects COMMERCIAL Attach(2)'6omplete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction. Minimum ten(10)working days after submittal date:Required,onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster.Site-Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. **"PROPERTY SURVEY required for all NEW-construction: Directions' .Fill out application completely. Owner&Contractor sign back of application,notarized If over$2600,a Notice of Commencement is required.(A/C upgrades over$7500) * Agent(for"the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same- OVER THE COUNTER PERMITTING; (copy of contract required) Reroofs if.shingles Sewers Service Upgrades A/C Fences(PlottSurvey/Footage) Driveways-Not over Counter if on public roadways..needs ROW .....� ... ._vr....y...nw . v...na i•NN.wuuv„ ...._._ ..... ....�. Building Department NOTICE OF DEED RESTRICTIONS:The undersigned understands that this permit may be subject to"deed"restrictions"which may be more restrictive than County regulations.The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES:If the owner has hired a contractor or contractors to undertake work,they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law,both the owner and contractor may be cited for a misdemeanor violation under state law.If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work,they are advised to contact the Pasco County Building Inspection Division—Lic.$nsing Section at 727-847-8009. Furthermore,if the owner has hired a contractor or contractors,he is advised to have the contractar(s)sign portions of the"contractor Block"of this application for which they will be responsible. If you,as the owner sign as the contractor,that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACTIUTILITIES IMPACT AND RESOURCE,RECOVERY FEES:,The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings,change of use in existing buildings,or expansion of existing buildings,as specified in Pasco County Ordinance number 89-07 and 90m07,as amended.The undersigned also understands,that such fees,as may be due,will be identified at the time of permitting.It is further understood that:Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a"certificate of occupancy"or final power release.If the project does not involve a certificate of occupancy or final power release,the fees must be paid prior to permit issuance.Furthermore,if Pasco County Water/Sewer Impact fees are due,they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713,Florida Statutes,as amended):If valuation of work is$2,500.00 or more, I certify that I,the applicant, have been provided with a copy of the"Florida Construction Lien Law—Homeowner's Protection Guide"prepared by the Florida Department of Agriculture and Consumer Affairs.If the applicant is someone other than the'owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner"prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT:I certify that;all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction,zoning and land development.Application is hereby made to obtain a permit to do work and installation as indicated.I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction,County and City codes,zoning regulations,and land development regulations in the jurisdiction.I also certify that I understand that the regulations of other government agencies may apply to the intended work,and that it is my responsibility to identify what actions must take to be in compliance.Such agencies include but are not limited to: Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands, Water/Wastewater Treatment. Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. Army Corps of Engineers-Seawalls, Docks, Navigable Waterways. Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. US Environmental Protection Agency-Asbestos abatement. - Federal Aviation Authority-Runways. I understand that the following restrictions apply to the use of fill: - Use of fill is not allowed in Flood Zone W" unless expressly permitted. If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume" will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. - If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction, I certify that fill will be used only to fill the area within the stem wall. - If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill, an engineered drainage plan is required. If I am the AGENT FOR THE OWNER,I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work,plumbing,,signs,wells,pools,air conditioning,gas,or other installations not specifically included in the application.A permit issued shall be construed to be a license to proceed with,the work and not as authority to violate,cancel,alter,or set aside any provisions of the technical codes,nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans,construction or violations of any codes.Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance,or if work authorized by the permit is suspended or abandoned for a period of six(6)months after the time the work is commenced.An extension may be requested,in writing,from the Building.Official for a period not to exceed ninety(90)days and will demonstrate justifiable cause for the extension.If work ceases for ninety(90)consecutive days,the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF.�.COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMP RO MENTS TO YOUR PROPERTY. IF YOU INTEND-TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER 0 ORNEY BEFORE RECORDING..YOU COMMENCEMENT. FLORIDA JURAT(F.S. 117.03) /0 �Z' OWNER OR AGENT CONTRACTOR scribed and sworn or affi ed)-VW e this, ub ri a nd swor4 a firmed)befor a this f Who is/are personally known to me or has/have produced W-134 i a e personally_known to me or has/have produced as identification. as identification. Pig"— Notary Public Notary Public Commiss o. Commis ' o. S 171 Name 9f No ary typed,printed or stamped Namd of Notary typed,printed c r stamped PATRICIA BURCHETT .P�1; PATRICIA BURCHETT MY COMMISSION#GG365171 MY COMMISSION#GG365171 EXPIRES:AUG 13,2023 WIRES:AUG 13,2023 OF" Bonded through 1st State Insurance °pf� Bonded through 1st State Insurance PA CO COUNTY, FLORIDA Permit No. 9 Date Permitted Builder Name/Owner Name &41A�_W_ ,�Control W County Parcel No. 41 ZO 060 SubDly: `ks� ��=�/ Address/Location 9 ClassificationfType of Use TRANSPORTATION.IMPACT FEE Rate. Sq.Ft Unit: 3 Exempt ❑Ves 0 No How Determined I ` Impact Fee Amount _ � � Zone Na. TAZ: SCHOOL IMPACT FEE Account (058) Single-Family Detached House Amount $ A kZ1 4 (057) Mobile Home _ :L�:�-- i (058) Other Residential 123) Collection fee Exempt [ Yes..Q No How Determined PARKS'AND RECREATION.FEE- Land Account Land Credit Land Total Recreation Account Recreation Credit Recreation Total Zone TOTAL AMOUNT $ ' Jfo�4 Exempt ❑Yes ❑No How Determined` s — LIBRARY FEE Land Accaunf Land Credit Land Total Facility Account Facility Credit Facility Total Exempt ❑Yes Q-No How Determined Total Amount RESOURCE FEE ERU TOTAL AMOUNT Prepared By ! Checked By NO CERTIFICATE OF OCCUPANCY WILL BE ISSUEf7-OR FINAL INSPECTION PERFORMED UNTIL THE TOTAL AMOUNTS;LISTED HAVE ' BL=EN PAID AND.. .'. RECEIPTED FOR BY A CENTRAL-.PERM.ITTIN©OFFICE-OF PASCO COUNTY Ackdoydedgement below does not Mply acceptance of contcqrrence,but aimply receipt of wook.of thin form,placing the bulldina permit owner on notice of thle'assessment and the conditlons of payment for same. DATE RECEIVED BY RECEIPT NO. DATE BY i f i —— �`a t ! ! I ! t ( 1 1 � �--• �1 1 57 a �52 f >,161. ! ,*60 a �� �s5'���! �s 58 FF- Q 1 FF=91.35� I FF--91,4 - o-z$ zs bt- f 16+00 40r 90 t ! t !, a i t a. a D. 4 Single Family Dwelling Plan Review Comments 1. F. .E; shall be a minimum of 8" above the road elevation and an engineered site plan. 2. Lots shall be. graded to.comply with R401.3 of the F.-B.C. 3. Compaction test required if 24" or more of fill dirt is brought in at any one place. 4. Tie in survey required before pouring concrete. 5. Driveways require a R.O.W. use permit. All 4 sides of driveway thru the sidewalk shall have expansion material. 6. All setbacks shall be met. T All property markers shall be uncovered and marked at time of first inspection. 8. All A.D.A. requirements shall be met: 9. No electric, plumbing,mechanical, or framing shall be-covered without an inspection and approval first. 10. All Garages shall comply with section R302.6 of the F.B.C. (Fire Separation). 11. Appliances shall not be installed in a location where subject to mechanical damage unless protected by approved barriers. M303.4 of the F.B.0 12. Water heaters-shall comply with section P607.3 of the F.B.C: 13. Foundation supports for A/C units shall be raised at least 3" above finished grade. M1308.1- 14. Return air in all bedrooms. F.B.C. M1620.4 15. Smoke detectors are to be installed in accordance_ with R313.1 of the F.B.C. 16. All glazing requirements are to be in accordance with R308.4 of the F..B:C; 17. All means of egress are to be in accordance'with R311 of the F.B.C. 18. "Green gypsum_board"shall not be used as a backer in showers or tubs. R702.4.2 F.B.C. 10. Combination-type AFCI breakers are required at all locations requiring an AFCI type breaker. 20. Carbon monoxide alarms will be required in new construction that uses fossil-burning heating or appliances or an attached garage. They shall be installed in accordance with the F.B.C: 21. All plumbing, mechanical, and electrical shall be separate from unit to unit. This includes all underground plumbing and eleI .ctric. 22. All 201'6 N.E.C. Codes will be enforced: 23. Tamper- Resistant Receptacles in accordance with 406.11 of the 2016 N.E.0 24. In accordance with the Land Development Code,lots shall be sodded before final at-least 10 feet around the structure. 25: 14403.5.3Hot water pipe insulation Insulation for hot water pipe with a minimum thermal resistance (R.-value) of R-3 shall.be applied to the following: Piping 3/: inch (1.9.1 mm)and larger in nominal diameter. Piping serving more than one dwelling unit. Piping located outsid,e'the conditioned space;. Piping from the water heater to a distribution manifold. Piping:located under a floor slab. Buried in piping. Supply and return piping in recirculation systems other than demand recirculation systems. 25.Slower door test shall be provided before C.O: 26.A copy of the ener�y-cacls shall be with permit at all times 27.. Copy of jnalinsulation report shall be provided with permit before Tnal 28. No fence, pool or enclosure .is issued with ahis perynit F.F.E.-Finished Floor Elevation F.B.C-Florida Building Code 6t'Edition R.O.W.-Right of Way A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code (2016) °y CITY OF , EP YRHILLS "City of Pure Water 5335 Eighth Street•Zephyrhills,Florida 33542-4312 (813)780-0000• Fax (813) 780-0005 GENE WHITF�ELD Mayor June 13, 2018 Mr.David Waronker CITY COUNCIL 1420 Celebration Blvd., Suite 200 LANCE A.SMITH Celebration,FL 34747 Council President Dear Mr.Waronker, KENNEM M.BURGESS,JP, Vice President City of Zephyrhills Ordinance 1.003708, Section 12, Paragraph 5, provides that planned unit developments (PUD) approved prior to September 30, 1988 are CHARLES E.PROCTOR exempt from paying transportation impact fees unless amended to permit additional development that would generate traffic. W.A.LAN KNIGHT The Silver Oaks PUD was approved on its third and final reading on January 11, JODI WILKESON 1988, and therefore is exempt from paying transportation impact fees as stipulated in Ordinance 100308 provided the original permitted number of dwelling units remains the same. According to Todd Vande Berg, city planner,those numbers within the Silver Oaks PUD have remained constant. STEVEN F.SPINA City Manager Therefore,the Oaks at Pasco is exempt from paying these fees. A copy of Ordinance 1003-08 is provided for your information.The exemption and credits City Clerk, CMC page L L. M section is located a e 1.0. C on MATMW E.MAGGARD Sincerely, City Attorney 47 Steven F, Spina,PhD City Manager cc: Todd Vande Berg, City Planner Bill Burgess,Building Official Matthew E. Maggard, City Attorney PLOT PLAN DESCRIPTION:(AS FURNISHED) LOT 59, OAKS OF PASCO. AS RECORDED IN PLAT BOOK 80, PAGE(S) 113-118, OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. ON LOT CALCULATIONS LOT = 5,750 SQ. FT. LIVING AREA = 1,651 SQ. FT. GARAGE = 416 SQ. FT. ENTRY = 100 SQ. FT. LANAI = 260 SQ. FT. PA110 = 0 SQ. FT. DRIVEWAY = 328 SQ. FT. A/C PAD = 9 SQ. FT. WALKWAY = 30 SQ. FT. IMPERVIOUS = 49% = 2794 SQ. FT. a SOD = 2,956 SQ. FT. OFF LOT CALCULATIONS RIGHT OF WAY = 400 SQ. FT. i DRIVE APRON = 57 SQ. FT. _ PUBLIC S/W = 250 SQ. FT. GRAPHIC SCALE SOD = 93 SQ. FT. TOTALS 0 15 30 AREA = 6,150 SO. FT. DRIVEWAY = 385 SQ. FT. SIDEWALK = 280 SQ. FT. SOD = 3,049 SQ. FT. I 00 L0 I I I— e9 O 6 o 0 115.00'. O 29.8' wi S82•53'12„E e9 a s W o ,o.o � co Lw W U).-C� o.�a. a 5.0 215' 0co 0 bO peg I I \ 0 PROPOSED ,p' I I I W 3 c1+ N NS z , lo (p C3 0 0' FINISHED 92 00R TION a 0 0 6. , 20.5'COVERED -I z O I ENTRY .:;..::. 00 wW O¢_ plo ow zir 90N82'53' I 12" � \ 09 hS N82'53'12"W c o m O 20.00' o I in o W W I c0 \ I o v a m \ I al PREPARED FOR: N a I N U I $ o aW o �e < - 0 yoffz�;� o W BUILDING SETBACKS CL<N FRONT: 20' REAR: 10' SIDE: 5' SIDE STREET: 15' LEGEND: NOTES: — BUILDING SETBACK LINE PI POINT OF INTERSECTION POINT OF CURVATURE 1. PROPOSED ELEVATIONS SHOWN HEREON ARE BASED — - CENTERLINE PC POPT POINT OF TANGENCY" ON THE APPROVED ENGINEERING PLANS PREPARED — - - — RIGHT OF WAY LINE RP RADIUS POINT BY CORNELISON ENGINEERING & DESIGN INC. PRC POINT OF REVERSE CURVATURE 2. ELEVATIONS ARE BASED ON NAVD 1988 PROPOSED ELEVATION PCP PERMANENT'CONTROL POINT DATUM. TYP TYPICAL PROPOSED DRAINAGE FLOW CS CONCRETE SLAB THIS PLOT PLAN IS INTENDED FOR PERMITTING PURPOSES CONCRETE (p) CALCULATED(P) PER PLAT ONLY. THIS IS NOT INTENDED FOR THE CONSTRUCTION OF PB PLAT BOOK" THE PROPOSED STRUCTURE. THE CONTRACTOR AND/OR A/C AIR CONDITIONER PGS PAGES OWNER ARE REQUIRED TO VERIFY ALL SETBACKS, BUILDING S/W SIDEWALK SQ. FT. SQUARE FEET DIMENSIONS, AND LAYOUT SHOWN HEREON PRIOR TO ANY F.E.M.A. FEDERAL EMERGENCY-MANAGEMENT AGENCY CONSTRUCTION. F.I.R.M. FLOOD INSURANCE RATE MAP NAVD NORTH AMERICAN VERTICAL DATUM THIS IS NOT A SURVEY DEE DRAINAGE EASEMENT EVENT THIS IS A PLOT PLAN ONLY UE UTILITY EASEMENT FLOOD NOTE: I HAVE EXAMINED THE F.I.R.M. MAP NO. 12101CO289F' SURVEYOR NOTES: - - DATED 09/26/2014 AND FOUND THE SUBJECT PROPERTY APPEARS TO LIE 1. •THE SURVEYOR HAS NOT ABSTRACTED THE PARTIALLY IN ZONE "X' & °AE". ZONE"X', AREAS DETERMINED TO BE LAND SHOWN HEREON FOR EASEMENTS,"RIGHT OUTSIDE ETO BE SPECIAL FLOOD HAZARDPARREASZSUBJECT"TOREAS OF WAY, RESTRICTIONS OF RECORD WHICH INUNDATION BY THE 1%ANNUAL CHANCE FLOOD EVENT, BASE FLOOD MAY AFFECT THE TITLE OR USE OF THE LAND. ELEVATIONS DETERMINED TO BE 88.5', THE SURVEYOR MAKES NO GUARANTEES AS TO THE ABOVE INFORMATION. PLEASE CONTACT THE 2. NO UNDERGROUND IMPROVEMENTS HAVE BEEN LOCAL F.E.M.A. AGENT FOR VERIFICATION. LOCATED EXCEPT AS SHOWN. BEARING BASIS: BEARINGS SHOWN HEREON ARE BASED ON THE CENTERLINE OF A5 3. NOT VALID WITHOUT-THE AUTHENTIC BRADFORD WOODS DRIVE BEING N07i06'48"E, PER PLAT. ELECTRONIC SIGNATURE AND THE AUTHENTIC ELECTRONIC SEAL OF A FLORIDA LICENSED REVISED: A M E FZ' I CA N SURVEYOR AND MAPPER. (FIELD DATE:) S U RV E No'I N G p j Digitally signed by James W Weman dstc''we 1 DN:c=US,st=Flodda,l-0rlando, SCALE: 1' = 30 FEET $c MAPPING INC. '+'�'"��^• �f`' I—AMERICAN SURVEYING& JB � sse+s},s , A"*MAPPING,INC,cn=lames W APPROVED BY: -- ` —�' CERTIFICATION OF AUTHORIZATION NUMBER LB//6393 :•d� � Boleeman„ 3191 MAGUIRE BOULEVARD, SUITE 200 %; a'°�. F` r a _-email=jbbleman@asmco po ate.com FOR JOB No 191105 LOT 59 ORLANDO, FLORIDA 32803 =o....@as Date:2020A9300937:40-04'00' FIRM (407) 426-7979 Adobe Acmbat venion:11.0.23 DRAWN BY: RMB WWW.AMERICANSURVEYINGANDMAPPING.COM JAMES W."BOLEMAN PSM 6485 DATE PLOT PLAN 09 24 2020 JG