HomeMy WebLinkAbout20-955 City of Zephyrhills ;� PERMIT NUMBER�� .. - 5335 Eighth Street Zephyrhills, FL 33542 ELCMISC-000966-2020 f Phone: (813)780-0020 Fax: (813)780-0021 Issue Date: 11/05/2020 Permit Type: Electric Service Replacem_ ent/Misc P, operfy Number s ` i'" :"u' $treetA'dil�ess...�:� =#' �,:. 35 25 210140 00700 0100 7963 Sail Clover Lane :x�'^'.i�i•,T-.r.;-<�i - x"� '- �..:: ,, ..'�..e -. - k, rk ,s.;,'w- Fy "_ ;.4iS6 =.✓'an..w_ :.,.,.'3. ;,_ ;;Owrier,hiforination Permit�lnformation t. ;. Contractorinformat on `; Name: SHANE STONE TAYLOR Permit Type:Electric Service Replacement/M Contractor: FREEDOM SOLAR ENERGY SINGLETARY Class of Work:Add/Alter Residential Address: 7963 Sail Clover Ln Building Valuation:$0.00 ZEPHYRHILLS,FL 33542 Electrical Valuation:$39,435.40 Phone: (813)255-4486 Mechanical Valuation: Plumbing Valuation: G Total Valuation:$39,435.40 Total Fees:$355.77 Amount Paid:$355.77 Date Paid:11/5/2020 2:01:41 PM Project Description " fi ' �q4 f' . r y}, �'�X ,- INSTALLATION ROOF MOUNT SOLAR PV SYSTEM -��x:+a+e:==. _ _'�'�»: .APPlicatioii'Fees; Electrical Permit Fee $237.18 Electrical Plan Review Fee $118.59 REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each subsequent reinspection. Notice: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permit required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner:Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications add fee Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. L-*rn CONTRACTOR SIGNATURE PE IT OFFICE PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER 1 813-780-0020 City of Zephyrhills Permit App' a ion Fax-813a80-0021 Building Department Date Received Phone Contact for Permittin 727 940 256 tttttttt ttt t Owner's Name STONE SHANE&SINGLETARY TAYLOR wrier Phone mber 8132554486 Owner's Address 7963 SAIL CLOVER LANE,ZEPHYRHILLS,FL 33541 Owner Phone Number Fee Simple Titleholder Name I Owner Phone Number Fee Simple Titleholder Address JOB ADDRESS 1 7963 SAIL CLOVER LANE LOT# 10 SUBDIVISION ZEPHYR LAKES SUBDIVISION pARCEL ID# 35-25-21-0140-00700-0100 (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED B NEW CONSTR B ADD/ALT SIGN = DEMOLISH INSTALL REPAIR PROPOSED USE 0 SFR = COMM = OTHER TYPE OF CONSTRUCTION = BLOCK = FRAME = STEEL = DESCRIPTION OF WORK INSTALL ROOF MOUNTED SOLAR PV SYSTEM. 10.14kw BUILDING SIZE I I SQ FOOTAGE HEIGHT =BUILDING $ VALUATION OF TOTAL CONSTRUCTION =ELECTRICAL $ $39,435.40 AMP SERVICE = PROGRESS ENERGY = W.R.E.C. =PLUMBING $ �� D r 0=MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION � � I =GAS =^ ROOFING 0 SPECIALTY = OTHER FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES NO Illlltltlltltltlltitlllllitlltttlllla—t ' �� AAf BUILDER COMPANY SIGNATURE REGISTERED >License# F Address ELECTRICIAN P5739 -" _ COMPANY �`REEDOM SOLAR ENERGY SIGNATURE - �-"JJ REGISTERED N FEE CURREN Y/N Address ALL BLVD ZEPHYRHILLS FL 33542 License# CVC56 PLUMBER COMPANY SIGNATURE REGISTERED Y/ N FEE CURREA Address License# MECHANICAL COMPANY SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address I License# OTHER COMPANY SIGNATURE REGISTERED I Y/ N FEE CURREK Address License# It1tt111t1I1111111I1I1111111111111111it1t1111illlltlltlttllllllt111 RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Farms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stonnwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster;Site Work Permit for subdivisionsAerge projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction. Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence Installed, Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. "PROPERTY SURVEY required for all NEW construction. Directions:• Fill out application completely. Owner&Contractor sign back of application,notarized If over$2500,a Notice of Commencement is required. (A/C upgrades over$7500) Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage) Driveways-Not over Counter if on public roadways..needs ROW NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed"restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work,they may be required to be licensed in accordance with state and local regulations.'If the contractor is not licensed as required by law, both the.owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work,they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the"contractor Block"of this application for which they will be responsible. If you, as the owner sign as the contractor,that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings,change of use in existing buildings,or expansion of existing buildings,as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands,that such fees,as may be due,will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a"certificate of occupancy"or final power release. If the project does not involve a certificate of occupancy or final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due,they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713,Florida Statutes,as amended):,If valuation of work is$2,500.00 or more,I certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowners Protection Guide"prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the"owner',I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner'prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction,zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: - Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands,Water/Wastewater Treatment. - Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. - Army Corps of Engineers-Seawalls,Docks,Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. - US Environmental Protection Agency-Asbestos abatement. - Federal Aviation Authority-Runways. I understand that the following restrictions apply to the use of fill: Use of fill is not allowed in Flood Zone W"unless expressly permitted. - If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume"will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction,I certify that fill will be used only to fill the area within the stem wall. If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties,the owner may be cited for violating the conditions of the building permit issued under the attached permit application,for lots less than one(1) . acre which are elevated by fill,an engineered drainage plan is required. If I am the AGENT FOR THE OWNER,I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate,cancel,alter,or set aside any provisions of the technical codes,nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans,construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance,or if work authorized by the permit is suspended or abandoned for a period of six(6)months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety(90)days and will demonstrate justifiable cause for the extension. If work ceases for ninety(90)consecutive days,the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTOR EY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. FLORIDA JURAT(F.S.117 3) r� OWNER OR AGENT 49-1- CONTRACTOR IZ— — Subscribed and sworn to(or affir ore me this Subscribed and sworn to(or_ irit jad)�I ore me this �f by by r 1✓=�Y✓G biS: t. I�L Who is/are personally known to me or has/have produced Who is/are personally known to me or hasthave produced DL as identification. DL as identification. Notary Public Notary Public Commission No. Commission No. Name of Notary typed,printed or stamped Name of Notary typed,printed or stamped INSTR#2020184569ORBK10207PG2946 page 1 of 1 1110212020 09:32AM Ropt:2221810 Rec:10.00 DS:0.00 IT:0.00 Nikki Alvarez-Sowles,Esq.,Pasco County Clerk&Comptroller PAEPAAED BY:FREEDOM SOLAR EPN R Y 5739 GALL BLVD ZEPHYRHILLS FL 33542 Permit Number ParCeIII)Number NOTICE OF COMMENCEMENT State of Florida County Of PASCO THE UNDERSIGNED hereby gives notes that improvements will be made to certain real property,and in accordance with Section 713.13 of the Florida Statutes,the following Information Is provided In this NOTICE OF COMMENCEMENT. I.Dgggg 9n of lnpldescjfirtfon).,ZEPHYR LAKES SUBDIVISION PHASES 1 A 2A 2B&4A PB 80 PG 37 BLOCK 7 LOT 10 7963 Sail Clover Lane, 2 JR,,..99p .Me provements: Install Photovoltaic system on the roof 3.&wnO-r Information or Lessee information If the Lessee contracted for the Improvement, Shane Stone,Taylor§in%detarv7963 Sail Clover Lane,Zep_hy 11 33540 b)Name and address offee simple titleholder(If different than Owner fisted above) a)Interest in property: 10DIA 4.Contractor Information a)Name and address: -Gary Kernper-I-rLvdom Solar Energy-5739 Call.Blvd,Zephyrhillb,Fl,33542 b)Telephone No.: 813-395-5956 Fax No.:(optional) NIA 5.Surety(if applicable,a copy of the payment bond is attached) a)Name and address: NIA b)Telephone No.: ---------.......... c)Amount of Bond. 6.Lender a)Nam and address: NIA b)Telephone No.: 7.Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by Section 713.13(1)(a)T,Florida Statutes: a)Name and address; N/A ...... b)Telephone No-, FatcNo.:(optional) ...... &aJn addition to himself or herself,Owner designates N/A ............_ of .......... to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b),Florida Statutes, b)Phone Number of Person or entity designated by Owner. 9.Expiration date of notice of commencement(the expiration date may not be before the complelion of construction and final payment to the contracto,bud will be 1 year from B a date of rerng uNess afferent date is specfiad): 20 WARNING TO OWNER:ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713,PART 1,SECTION 713,13,FLORIDA STATUTES,AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY,A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION.IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. Un I.ejury,II—declare that I have read the foregoing notice of commencement and that the facts stated therein are true to the beat of my 1 a dglief-.1i _5kgte Stome_Taylor Singletary The foregoing instrument was aolotowfedged before me this ...... dayof by ............._ as __17�4Hic No.t.ary ....... (typo ofeutharity.eq.offioer,trustee.allarvyin fed) for _fkhar!t.Sjioqg,Taylor S�!irje r v�Ln- Mme of Person) (type.F.Wbority 9.9.Acer.trust-,elt—y in Wit for (name of party on behalf of Mom Instrument was executed}. Personalfit Know iiWUDE_ID Type of ID DL Notary Signature Printname Tashollw.ss. --------- M. comniwmtk"016743 EV1n*A*1,2024 JY SCOPE OF WORK P-1 47299 THIS PROJECT INVOLVES THE INSTALLATION OF A PHOTOVOLTAIC POWER SYSTEM.SOLAR PANELS WILL BE RACKED USING A PREENGINEERED RACKING SYSTEM.THE RACKED MODULES WILL BE ELECTRICALLY CONNECTED WITH DC TO AC POWER INVERTERS AND INTERCONNECTED TO THE LOCAL UTILITY USING MEANS AND METHODS CONSISTENTe O WITH THE RULES FOT C D BY THE LOCAL UTILITY AND PERMITTING JURISD Q , THIS DOCUMENT HAS BEEN PREPARED FOR THE PURPOSE OF Sylvan Learning DESCRIBING THE DESIGN OF A PROPOSED PV SYSTEM WITH Ll.l of Zephyrhills ENOUGH DETAIL TO DEMONSTRATE COMPLIANCE WITH H APPLICABLE CODES AND REGULATIONS.THE DOCUMENT C') SHALL NOT BE RELIED UPON AS A SUBSTITUTE FOR >- P�2 FOLLOWING MANUFACTURER INSTALLATION INSTRUCTIONS. Cl) LLJ THE SYSTEM SHALL COMPLY WITH ALL MANUFACTURERS U LL 5d LISTING AND INSTALLATION INSTRUCTIONS,AS WELL AS ALL LLi Z APPLICABLE CODES.NOTHING IN THIS DOCUMENT SHALL BE 11.1INTERPRETED IN A WAY THAT OVERRIDES THEM. j CONTRACTOR IS RESPONSIBLE FOR VERIFICATION OF ALL CONDITIONS,DIMENSIONS,AND DETAILS IN THIS DOCUMENT. ..• Mapcata SYSTEM DETAILS PROJECT DETAILS NEW GRID-INTERACTIVE 0 Z a PROPERTY OWNER SHANE STONE 1 PLOT DESCRIPTION PHOTOVOLTAIC SYSTEM WITH NO wPROPERTY ADDRESS ZEPHYRHILLS,FL US PV-1 SCALE:NTS 0 BATTERY STORAGE N DC RATING OF SYSTEM 10.14KW a w U) ZONING RESIDENTIAL USE AND OCCUPANCY ONE-OR TWO-FAMILY DWELLING / Richland AC RATING OF SYSTEM 9.77KW I. CLASSIFICATION GROUP(GROUP R3) .1 AC OUTPUT CURRENT 40.6A 0 UTILITY COMPANY DUKE ENERGY FLORIDA INVERTER(S) N/A ELECTRICAL CODE 2014 NEC(NFPA 70) s}5 MODULE SUNPOWER SPR-E20-327-E-AC 327-E-AC FIRE CODE 2015 NFPA 1 zephyr hills (2)BRANCH OF 10 MICROINCH MICROINVERTERS S OTHER BUILDINGIQ7X-96-2 US f� ARRAY WIRING (1)BRANCH OF 11 IQ7X-96-2-US CODES 2017 FL BUILDING CODE MICROINVERTERS Zephyrhills 7uah -hells Upper INTERCONNECTION DETAILS CONTRACTOR INFORMATION West Hillsborough COMPANY FREEDOM SOLAR ENERGYf Skydive City/Z-Hills 19 Preserve NEW SUPPLY SIDE AC CONNECTION POINT OF CONNECTION PER NEC 705.12(A) LICENSE NUMBER 56990(CVC) Zephyrhilly ADDRESS 36139 PINE BLUFF LOOP,DADE CITY, South UTILITY SERVICE 120/240V 1 0FL 33525 INSIDE PANELBOARD,PROTECTED LOCATION BY FUSED EATON DG222NRB,2- PHONE NUMBER (813)300-3382 POLE,60A, 240VAC CONTRACTOR SIGNATURE PROJECT Crystal Snnngs ,f9RatA Win. SUMMARY ALL WORK SHALL COMPLY WI I H I'P V MLII'i DOC ID:147299-181829-1 2 LOCALE CODES FLORIDA BUILDING CODE, NATIONAL ELECTRIC CODE, DATE:10/19/20 PV-1 SCALE: NTS AND THE CITY OF ZEPHYRHILLS CREATOR:J.V. ORDINANCES REVIEWER: REVISIONS REVIEW DATE � 207.0 CITY OF ZEPHY I PLAN EXAMINER . Pv-� PM1-31 `AC MODULE MODULES GENERAL ELECTRICAL NOTES P-141299 �__ 327W / REF. OTY. MAKE AND MODEL PMAX(AC) MAX OUTPUT CURRENT AC VOLTAGE CECWEIGHTEDEFFICIENCY UTILITY HAS 24-HR UNRESTRICTED ACCESS TO ALL / PMI-31 31 SUNPOWERSPR-E20327-E-AC 315W 1.3A 240.OV s7.s% 1 PHOTOVOLTAIC SYSTEM COMPONENTS LOCATED AT THE i 1 I PASS-THRU BOXES AND COMBINERS 1 111N 1 ,01N 1 10 IN SERVICE ENTRANCE. I I I Q Q REF. QTY. MAKE AND MODEL RATED CURRENT MAX RATED VOLTAGE JB1 I SOLADECK0799.5 WITH 01613 KITOREQUIV. 30A 240VAC/600VDC 2 MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. BRANCH BRANCH BRANCH Q Q 64A 240VAC 1 I ICONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS Cl I ENPHASE 10 COMBINER+OR EQUIV. I 1 I DISCONNECTS I I OCPDS I 3 SUNLIGHT RESISTANT PER NEC ARTICLE 300.6(C)(1)AND ; REF. QTY. MAKE AND MODEL RATED CURRENT MAX RATED VOLTAGE REF. 1 QTY.1 RATED CURRENT MAX VOLTAGE ARTICLE 310.10(D). r L -J SW1 1 EATON DG222NRB OR EQUIV. 60A 240VAC CB1-3 3 20A 240VAC I Fl-2 2 60A 240VAC CONDUCTORS EXPOSED TO WET LOCATIONS SHALL BE L, FUNCTION Box SYSTEM SUMMARY NOTES 4 SUITABLE FOR USE IN WET LOCATIONS PER NEC ARTICLE JB1 BRANCH 1 BRANCH 2 BRANCH 3 0 ENPHASE SYSTEM MEETS REQUIREMENTS FOR PHOTOVOLTAIC RAPID SHUTDOWN SYSTEM(PVRSS),AS PER NEC 690.12. 310.10(C). 2 NVERTERS PER BRANCH 11 10 10 w AX AC CURRENT 14.41A 13.1A 13.1A MICROINVERTER BRANCH CIRCUIT CONDUCTORS ARE MANUFACTURED ENPHASE Q CABLES LISTED FOR USE IN 20A OR LESS CIRCUITS OF ENPHASE IQ GROUNDING NOTES 3 AX AC OUTPUT 3,465W 3,150W 3,150W ®MICROINVERTERS.THEY ARE ROHS,OIL RESISTANT,AND UV RESISTANT.THEY CONTAIN TWO 12 AWG CONDUCTORS OF TYPE THHN/THWN-2 DRY/WET AND (J) ARRAY STC POWER 10,137W CERTIFIED TO UL3003 AND UL 9703.THE CABLE'S DOUBLE INSULATED RATING REQUIRES NO NEUTRAL OR GROUNDED CONDUCTOR. AC COMBINER ALL EQUIPMENT SHALL BE PROPERLY GROUNDED PER THE ARRAY PTC POWER 9,390W 1- L B1 B2 53 AX AC CURRENT 41A UNGROUNDED SYSTEM DC CONDUCTORS SHALL BE COLOR-CODED AS FOLLOWS.DC POSITIVE SHALL BE RED(OR MARKED RED)AND DC NEGATIVE SHALL BE REQUIREMENTS OF NEC ARTICLES 250&690 w r� OA oA A c1 MAX AC POWER OUTPUT 9,765W BLACK(OR MARKED BLACK) PV MODULES SHALL BE GROUNDED TO MOUNTING RAILS -' ERATED AC POWER OUTPUT 9,155W U ALL METAL ENCLOSURES,RACEWAYS,CABLES AND EXPOSED NONCURRENT-CARRYING METAL PARTS OF EQUIPMENT SHALL BE GROUNDED TO EARTH AS USING MODULE LUGS OR RACKING INTEGRATED w 4. REQUIRED BY NEC 250.4(B)AND PART III OF ARTICLE 250 AND EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED ACCORDING TO NEC 690.45(A).THE 2 GROUNDING CLAMPS AS ALLOWED BY LOCAL JURISDICTION. LU MF1-2 GROUNDING ELECTRODE SYSTEM SHALL ADHERE TO NEC 690.47 AND NEC 250.169.THE DC GROUNDING ELECTRODE SHALL BE SIZED ACCORDING TO NEC �DISCONTEECT 250.166 AND INSTALLED IN COMPLIANCE WITH NEC 250.64. ALL OTHER EXPOSED METAL PARTS SHALL BE GROUNDED - J r sw1 USING UL-LISTED LAY-IN LUGS. 60A PV SYSTEM DISCONNECT SHALL BE A VISIBLE KNIFE-BLADE TYPE DISCONNECT THAT IS ACCESSIBLE AND LOCKABLE BY THE UTILITY. ® THE DISCONNECT SHALL INSTALLER SHALL CONFIRM THAT MOUNTING SYSTEM HAS WLL BE LOCATED WITHIN 10 FT OF UTILITY METER.DISCONNECT SHALL BE GROUPED IN ACCORDANCE WITH NEC 230.72. BEEN EVALUATED FOR COMPLIANCE WITH UL 2703 1 >_ (200A MSP W/200A MCB) POINT-OF-CONNECTION IS ON THE SUPPLY SIDE OF SERVICE DISCONNECT,INSIDE PANELBOARD ENCLOSURE USING UNUSED TERMINALS,TERMINALS THAT 3 °GROUNDING AND BONDING"WHEN USED WITH PROPOSED Q I ® ARE SUITABLE FOR DOUBLE LUGGING,OR USING OTHER LOCALLY-APPROVED METHODS AND HARDWARE,IN COMPLIANCE WITH NEC 705.12(A).THE C O z PV MODULE. PANELBOARD SHALL HAVE SUFFICIENT SPACE TO ALLOW FOR ANY TAP HARDWARE AS REQUIRED BY NEC 110.3 AND NEC 312.8 - 1 LOADS 4 ALL GROUNDING SYSTEM COMPONENTS SHALL BE LISTED 0 OF- N }_ __ Q O CONDUCTOR AND CONDUIT SCHEDULE W/ELECTRICAL CALCULATIONS FOR THEIR PURPOSE LL C/) CURRENT-CARRYING IF THE EXISTING MAIN SERVICE PANEL DOES NOT HAVE A F- DTYPICAL CONDUCTOR CONDUIT/CABLE CONDUCTORS IN CONDUIT OCPD EGC - TEMP.CORR. FILL CONT. MAX.CURRENT BASE DEBATED TERM. AMP.@TERM. /CABLE FACTOR FACTOR CURRENT (125%) AMP. AMP. TEMP.RATING TEMP.RATING 5 VERIFIABLE GROUNDING ELECTRODE,IT IS THE UTILITY METER 12 AWG THWN-2, 0.5"DIA FLEXIBLE 12 AWG THWN-2, Ac IM/HR 240/120V 1m,3W 1 1 6 20A 0.76(54C) 0.8 14.41A 18.OtA 30A ,s.zaA 90°c 30A CONTRACTOR'S RESPONSIBILITY TO INSTALL A SUPPLEMENTAL GROUNDING ELECTRODE. GEC 2 1 12 AWG THWN-2, 0.5"DIA.FLEXIBLE 6 20A 12 AWG THWN-2, 0.76(54°C) 0.8 13.1A 16.38A 30A 18.24A 90°c 30A COPPER STEEL COPPER AC SYSTEM GROUNDING ELECTRODE CONDUCTOR(GEC) 1 12 AWG THWN-2, 0.5"DIA.FLEXIBLE 6 20A 3 12 AWG THWN-2, 0.76(54`C) 0.8 13.1A 16.38A 30A 18.24A 90°C 30A 6 SHALL BEA MINIMUM SIZE#8AWG WHEN INSULATED,#6AWG COPPER STEEL COPPER COPPER STEEL COPPER 6 AWG THWN-2, 10 AWG THWN-2, 4 1 0.75"DIA.EMT 2 N/A 0.71(56°C) 1.0 40.61A 50.76A 75A 53.25A 75°C 65A IF BARE WIRE. COPPER COPPER EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED 5 1 6 AWG THWN-2, 0.75"DIA.EMT 2 60A X2 2 N/A 0.96(34C) 1.0 40.61A 50.76A 75A 72A 75°C 65A COPPER ACCORDING TO NEC ARTICLE 690.45,AND BE A MINIMUM OF #10AWG WHEN NOT EXPOSED TO DAMAGE,AND#6AWG SHALL BE USED WHEN EXPOSED TO DAMAGE GROUNDING AND BONDING CONDUCTORS,IF INSULATED, 8 SHALL BE COLOR CODED GREEN,OR MARKED GREEN IF #4AWG OR LARGER SINGLE-LINE DIAGRAM PROJECT ID: 147299 DATE: 10119120 CREATED BY: J.V. CHECKED BY: REVISIONS SINGLE-LINE DIAGRAM PV-2 SCALE: NTS Pv 2 SW1 -DISCONNECT EACH DISCONNECTING MEANS FOR POINT-OF-INTERCONNECTION OR AT MAIN LABELING NOTES P-1 47299 EATON DG222NRB O PHOTOVOLTAIC EQUIPMENT(SW1) O SERVICE DISCONNECT(MSP) O AC DISCONNECT(SW1) O O O O O ALL N PLAQUES015NF AND SIGNAGE LLBENTALLE REQUIRED BREQ1 I NEC AND 2015 NFPA 1 WILL BE INSTALLED AS REQUIRED. I WARNING ! I CAUTION I LABELS,WITH ASI Z535.4GWH CHAND MARKING REQUIR S THAT COMPLY DANGER, ELECTRIC SHOCK HAZARD.DO NOT TOUCH POWER TO THIS BUILDING IS ALSO FROM ROOF 1° IMUM AC OPERATING Cu RRENT 45. MSP-MAIN SERVICE PANEL TERMINALS.TERMINALS ON BOTH LINE ANDWARNING,AND CAUTION SIGNS USED THE STANDARD LOAD SIDES MAY BE ENERGIZED IN THE OPEN MOUNTED SOLAR ARRAY WITH SAFETY P.1AXIhIiJAh AC L3l4TihIG VOL 240V 2 HEADER COLORS,HEADER TEXT,AND SAFETY ALERT DISCONNECTS AS SHOWN SYMBOL ON EACH LABEL.THE ANSI STANDARD O O POSITION. REQUIRES A HEADING THAT IS AT LEAST 50%TALLER NEC 690.17(E) NEC 690.56(B) AND NEC 705.10 NEC 690.54 THAN THE BODY TEXT,IN ACCORDANCE WITH NEC 110.21(B). w ANY AC ELECTRICAL PANEL THAT IS FED BY AC SOLAR DISCONNECT(SW1) 5 SEE NOTE NO.4(SW1) BOTH THE UTILITY AND THE PHOTOVOLTAIC A PERMANENT PLAQUE OR DIRECTORY SHALL BE I- SYSTEM(SW1,MSP) INSTALLED PROVIDING THE LOCATION OF THE SERVICE (f) 3 DISCONNECTING MEANS AND THE PHOTOVOLTAIC >_ SYSTEM DISCONNECTING MEANS IF NOT IN THE SAME W LOCATION IN ACCORDANCE WITH NEC 690.56(B). J PHOTOVOLTAIC AC DISC , •• , DUAL POWER SODURC�E.8EVCOND SOURCE IS LABEL(S)WITH MARKING,"PHOTOVOLTAIC SYSTEM w • EQUIPPED WITH RAPID SHUTDOWN,"SHALL BE LOCATED W PHOTOVOLTAIC SYSTEM. 4 AT POINT-OF-INTERCONNECTION OR AT MAIN SERVICE in_ DISCONNECT THE LABEL SHALL HAVE 3/8"TALL Q J NEC 690.13(B) NEC 690.12 AND NEC 690.56(C) NEC 705.12(D)(3) LETTERS AND BE REFLECTIVE WITH WHITE TEXT ON A RED BACKGROUND w J W = O Ow O U N W 1=_ (9 SAFETY LABELS DOC ID:147299-181829-1 DATE:10/19/20 CREATOR:J.V. REVIEWER: REVISIONS PV-3 ROOF PROPERTIES P-147299 ROOF MATERIAL COMPOSITION SHINGLE(1 LAYER) SLOPE 6/12(26.6 ) DECK SHEATHING 15/32"OSB CONSTRUCTION TRUSSES(2X4 TOP-CHORD),241N OC MODULE MECHANICAL PROPERTIES RIDGE MODEL SUNPOWER SPR-E20-327-E-AC UJ DIMENSIONS(AREA) 61.31N X 41.21N X 1.81N(17.5 SQ FT) (n WEIGHT 41LB C- LlJ MOUNTING SYSTEM PROPERTIES W w 72.01N(ZONE 1) D .j MAX.ALLOW.RAIL SPAN 48.01N(ZONE 2) 0 J 24.01N(ZONE 3) _w = 72.01N(ZONE 1) of � MAX.MOUNT SPACING 48.0IN(ZONE 2) 24.0IN(ZONE 3) JMAX.ALLOW. LJJ 28.81N(ZONE 1) Q 0 Z CANTILEVER 19.21N(ZONE 2) 2 U) 0 LLJ 9.61N(ZONE 3) Q N GROUNDING AND INTEGRAL GROUNDING CERTIFIED Luj BONDING TO UL 2703 REQUIREMENTS - NOTES TRUSS LOCATIONS ARE APPROXIMATE.ACTUAL I (' 1 LOCATIONS MAY DIFFER AND CONTRACTOR MAY NEED TO ADJUST MOUNT LOCATIONS.IN NO CASE SHALL THE MOUNT SPACING EXCEED"MAX.MOUNT SPACING" SAVE WIND ZONE I ❑ WIND ZONE 11 WIND ZONE III ATTACHMENT PLAN (ORTHOGONAL PROJECTION ATTACHMENT FV-4 SCALE: 1/8"=1' PLAN DOC ID:147299-181829-1 DATE:10/19/20 CREATOR:J.V. REVIEWER: REVISIONS PV-4 E-Series:E20-327 I E19-320 SunPower®Residential AC Module SUN POWER' - inverter Model:Enphase IQ 7XS(1Q7xs-96-ACM-US) @240 VAC @2D8 VAC _.._----------...................................................-----_-........-.--.......-..-.._...."..-..............._................._.......--....._"-..---.....__........... :eak Oulrut nowe ..0\A a0 VA - SunPower®E-Series: E20-327 I E19-320 J,a ,,,t ,.nn_t�--L? ;P ..rya•,`r.. ,. -_'la/211-?64 2.08/183.._29 -- SunPower Residential 1 ?(single phi )..-.-.-.. 10(: 0 pole)vrye-._ 97.51. •.:•nr_ AC Module -------------- --........""....... ---............... ......._._...._.......---........--------..._------------------------_....--.-- —. ----------..-----........_._..._.....-.. . i_ S.R A rms Built specifically for use with the SunPower Equinoxlm system,the only fully integrated solution designed,engineered,and warranted kyyone III --------_..._..-----------.._._._._------------------------.....------- ._...-------------- .._............._._.....; manufacturer. - 18 mH i .I-r a*;S7a1I(- lag _......-...._..............-....-..-._...... �,. Maximum Power.Minimalist Design. ......................_._-_._...__.___.."--._..__._.._..........--_-...._._.—._....__._..._.._....._.-_.___..._°-._.__.............. ..................... �i Industry-leading efficiency means more, wer and savings - - --.-..-.___............... ............._._.-----........_------......__............_.___.-.....-, per available space.With fewer modules required and sr<-b2u-su-e-A� SPR-E19.320-E-AC Warran:ie _ --.... ..._... ....._. ......_......_ hidden microinverters,less is truly more. __...._..-..-..... ..._. .. _ .trc=.lit w C:n r, Nom.Prwer"(Pnum' ......3._7.14.. 320 VV ... -- .__--------...._..........__....................._ ........__.................-....__..._..._......_._.__...-"......... .. ,........._.......__............-•--ii ---- Puwer : Highest Lifetime Energy and Savings. Moduli:Efric rncV -o .1 Cc "'r at' n . ft 1711 AC MModul`(Ty(",e 2 fire rated) L f i E .Temp"C.Oei tr esr.,1 (1�, nt•�r r, 4;° •UL�-'R?9 1/I (r�I UJ? Designed to deliver 60%more energy over 25 years ir• _.........._..__... _. to:npllan�e r , s real-world conditions likepartial shade and high temperatures.' rlr e bvl: d,cd s •Icr CSA-(laa 8 Shade i'rrl Integrat/lie.•dult le,:.l maaimw?1 .i;1N CS1-:.�.2....NO 1Q".1 O1 power po hitacking CA Rule-,.'1(Ut.1741 SA)= �•- (n ildnn 4nlLlai alid Reauiv..Power riiuihy) Fundamentally Different. p Max Ambie,`T;,•i ....-._..;an,-w I 40"Ctu*8s•:C> _._._......_..._._ _._.._ ill`adP�"R.1pd4:hutlownEgiiipmenr i.ee, U to F nables installation In accord r e with: And Better. >, nua 60% .........__-_......--.._.-..__......_...__...._._._........_._.__._....,,...._...._ -....._....._._._._.._._...._.._. Wind:62 pat3000 Pa,305 kg/m2 front&back NEC 690.12 Rapid Shutdown(inside and outside the array) more Max.Lea 7 ;now:125 psf,6000 Pa•611 kglm�front ...,_..,_._................._.__......................._........... ..... .. NEC 69(1.15 AC Connectors,690.33(A)(F7(1) nn�.. lifetime ................._..._........................_._._.................................. -Impart Rasis'ariCE 1 inch(25 mm)clinmeter hail at S2 mph(23 m's) energy - -------- .\rrc n used with Invi.i,ounr racking and Invisitlouon acnrworiC$ (UL_'t'9): N a)lar Cells 96 Kloncays(alline Maxeon Gen ule III Mud pr'oundinp,and bonding through InvisiMarnt st - Class A fire rated The SunPower,'MaxeoneSolar Cell Front Glass µigh-tr,nsrnission tempered glass with When used with AC module Q Cables and accessories(t4.€:/LA arm Years of operation anti.reflective coating I UL,2278'.. ...........:.._...._..........._......................._......-............................._...............,..,,........_......,.....,..................................... • Enables highest-efficiency Rated for load break di curmpct modules available.° 3 o n'imental Raring Outdoor rated _ ___ .--__. . Best Reliability.Best Warranty. name (is s 1 blank a„adi ed(highesiAA2;rArat,ng) I Flt)te5c IcienUal induced degradation lice • Unmatched reliability' , Weight 42.9 lbs(19 5 kF) 656 mm(61 im.1 • Patented solid metal foundation With more than 25 million modules deployed arounc, . .......:.. ........_....._....................-.................................................__................_._...._......... ............-.......... the world,SunPower technology isproven to last.That's Recommended Max 1.3 in.(33 mm) prevents breakage anticorrosion Mudule.S acin P € Why we stand behind our module and microinverter -...................................................... ................................................................................ .0 ,SunPower 3,0 cn'nparen me a car,ven?m,ha revaduie in name-;,l,md array,I,'bO w uhf a6 mm with the industry's best 25-year Combined Power and €fficient,approx E h ,4%rr r ,:r y>erwartr•,a>donrhrd-partyr,ar',.c tt"6m> haracterizat ion and PVSom„ 7 ft yrsivwerntraar or,(C.muea.,Z Fab."Sun Pcwr. Product Warranty,including the highest Power Warran Module oegrad or :r t p?wP whi '0l3 ≥Ba>ed on scare.,cf.ra.ashb.t?.+9c.,.,fomwe.»;t._s o0 tob to manr:Pa tin,r lri.aso 10a6mm -.3a mm in solar. )anuary2017. (41• .2 ina 3#11ankin"Fraunhofe,PV ra,arac,i,ty in,tiaove jrSlAar Gpodules'Pa?t3."CVTecnp®x• px. r« Maga2me,201'S.Cans.aiCa.2,rrt ai."tu,,r owerMnduir Deg adation rate:'≥um"owe wr,1 t i pape,,2013. Co.A 4FaCrory setto1 I7a20!4d fart e, ays CA Rule 2 i de!aot mte,ngsp rPi, a.tuann 393 mm Factory-integrated MIcroinverte r a rommsz,oninp ne k[lunn r r I,' n: ,de 4sre ,11 i.r more nbrn n6sln( Sstandatd re c Cr,ct+7n s, 00 CCPm<.r ad nc.Ara1 r)Nr2 ea ,t • Simpler,fester installation c ^" ;tanda,d:sorts r Lp.(Cn Cf inn an,rafri.All tin v ak- ,ui:yr,r a e:'Chin' f o .:a' module• a3v mm • Integrated wire managertient, EuS. 12% 6 Ths produces JL e.o tl a. CR E.nd, neo n• with NEC,nR and NEC 211 7 9 az Oz21r) rapid shurdown • -_- more and(22.1-2015 i use 6.r-218 1 p 1 O'Ndown or 6 V lyaterm,u's,AC And DC.C power who r installe0 ac 6 d IN CO S Cuc,br c c • [nklnee ad and calibrated by m ` � in year 5c x w toe 3V er mr +P 43 mu rete n<..ltorrr it, .+wovennwn+ so Sunl'ownr for Sun Power moll l leS m ,tx 25 c rrtrsd?ta!•_es enS-ndeS.^a,euiwea wwv�,_0unpower.eorr,resacasr,eF, - ' /I •�' W 3,,y' a If a,i'aas ndlo 1,inti1 iNunhhnCare subin t Co cha uFra witho,i1m : LISTED S �✓ N P Y * ♦ E '2011 'LrEEr ne rrf,aoe9',in A.i Ri hus Ra cored.SUNEO!'FO.,Ins Mole Fee Pafamance:Type 2 •t dP d.P lop? •d MAXpr I, e0ls,r a r ade ,rks of Sun?6wn, Years of operation r r,n:` ,,.F e•I S a••i,u00 t.,-n'-ca.n , i il 2 JN°O'EP .' - r.a4 •e S, ,Ty and Insr.?vatic;Instrucunns to,details 331948 RevA P, •• • RSTC Enterprises, Inc. 2214 Heimstead Road Eau Claire, WI 54703 ( LADECK 715-830-9997 FLASHED PV ROOF-MOUNT COMBINER/ENCLOSURES Outdoor Photovoltaic Enclosures 0799 Series Composition/Cedar Roof System ETL listed and labeled Report#3171411 PRT-002 Revised May, 2018 _____________ L • UL50 Type 3R, 11 Edition Electrical equipment enclosures • CSA C22.2 No.290 Nema Type 3R III • Conforms to UL 1741 Standard 0799 Series Includes: SolaDeck 0799-2S 0799-2 Wire size 2/0-14 0799-5 Wire size 14-6 0799-D Wire size 14-8 Models available in Grey,Black or Stainless Steel Basic Specifications Material options: • Powder coated, 18 gauge galvanized 90 steel (1,100 hours salt spray) • Stainless steel SoleDeck 0799-5G Process-Seamless draw(stamped) Flashing- 15.25"x 17.25" Height-3" Cavity-255 Cubic inches Base Plate: • Fastened to base using toggle fastening system - • 5 roof deck knockouts — • Knockout sizes: (3).5", (1).75"and (1) 1" • 8", 35mm slotted din rail • Ground Block Passthrough and combiner kits are available for either SolaDeck0799-DG AC or DC applications. Product compliance: No Data F.T*N _______________ Powering Business Worldwide pe.eaton.com ©2016 Eaton. All rights reserved. Eaton general duty cartridge fuse safety switch DG222NRB UPC:782113144221 Dimensions: • Height: 14.38 IN • Length: 14.8 IN • Width: 9.7 IN Weight:10 LB Notes:Maximum hp ratings apply only when dual element fuses are used. 3-Phase hp rating shown is a grounded B phase rating, UL listed. Warranties: • Eaton Selling Policy 25-000, one (1)year from the date of installation of the Product or eighteen (18)months from the date of shipment of the Product, whichever occurs first. Specifications: • Type: General duty, cartridge fused • Amperage Rating: 60A • Enclosure: NEMA 3R • Enclosure Material: Painted galvanized steel • Fuse Class Provision: Class H fuses • Fuse Configuration: Fusible with neutral • Number Of Poles: Two-pole • Number Of Wires: Three-wire • Product Category: General duty safety switch •Voltage Rating: 240V Supporting documents: • Eatons Volume 2-Commercial Distribution • Eaton Specification Sheet- DG222NRB Certifications: • UL Listed Enphase IQ 7X Microinverter Enphase Microinverters AP✓1ERIi INPUT DATA(DC) IQ7X-96-2-US and IQ7X-96-8-US Commonly used module pairings' 320W-460W+ Module compatibility 96-cell PV modules Maximum input DC voltage 79.5 V Peak power tracking voltage 53 V-64 V Operating range 25 V-795 V Min/Max start voltage 33 V/79.5 V The high-powered smart grid-ready Max DC short circuit current(module Isc) 10 A Enphase Enphase IQ 7X Micro'° dramatically simplifies the overvoltage class DC port 11 DC port backfeed current 0 A Q 7X M i e ro i nve rte r installation process while achieving the highest pV array configuration 1 x 1 ungrounded array;No additional DC side protection required; system efficiency for systems with 96-cell modules. AC side protection requires max 20A per branch circuit OUTPUT DATA(AC) @ 240 VAC @ 208 VAC Part of the Enphase IQ System,the IQ 7X Micro Peak output power 320 VA integrates with the Enphase IQ Envoy'°,Enphase IQ Maximum continuous output power 315 VA Nominal(L-L)voltage/range' 240 V/211-264 V 208 V/183-229 V Battery'°,and the Enphase Enlighten" monitoring Maximum continuous output current 1.31 A(240 VAC) 1.51 A(208 vac) and analysis Software. Nominal frequency 60 Hz Extended frequency range 47-68 Hz The IQ Series Microinverters extend the reliability AC short circuit fault current over 3 cycles 5.8 Arms standards set forth by previous generations and Maximum units per 20 A(L-L)branch circuit' 12(240 VAC) 10(208 VAC) Overvoltage class AC port III undergo over a million hours of power-on testing, AC port backfeed current 18 mA enabling Enphase to provide an industry-leading Power factor setting 1.0 warranty of up to 25 years. Power factor(adjustable) 0.85 leading...0.85 legging EFFICIENCY @240 VAC @208 VAC CEC weighted efflcien a 97.5% 70% MECHANICAL DATA Ambient temperature range -40°C to+60°C Relative humidity range 4%to 100%(condensing) Connector type(IQ7X-96-2-US) MC4(or Amphenol H4 UTX with optional Q-DCC-5 adapter) Easy to Install Connector type(IQ7X-96-B-US) Friends PV2,may require adapters for modules with MC4 or UTX connectors: PV2 to MC4:order ECA-S20-S22 Lightweight and simply -PV2 to UTX:order ECA-S20-S25 1 Faster installation with improved,lighter two-wire cabling Dimensions(WxHxD) 212 mm x 175 mm x 30.2 mm(without bracket) • Built-in rapid shutdown compliant(NEC 2014&2017) Weight 1.08 kg(2.38 Ibs) Cooling Natural convection-No fans Approved for wet location:. Yes Efficient and Reliable Pollution degree PDL3 Enclosure Class II double insulated,corrosion resistant polymeric enclosure • Optimized for high powered 96-cell*modules Environmental category/UV exposure rating NEMA Type 6/outdoor • Highest CEC efficiency of 97.5% FEATURES 4• • More than a million hours of testing Communication Power Line Communication(PLC) • Class II double-insulated enclosure Monitoring Enlighten Manager and MyEnlighten monitoring options _ =f UL listed Compatible with Enphase IQ Envoj Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load-break disconnect required by NEC 690, Smart Grid Ready Compliance CA Pule 21(UL 1741-SA) UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B, ICES-0003 Class B, Complies with advanced grid support,voltage and CAN/CSA-C22.2 NO.107.1-01 frequency ride through requirements This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems,for AC • Remotely updates to respond to changing and DC conductors,when installed according menufacturer's instructions, grid requirements • Configurable for varying grid profiles Meets CA Rule 21 (UL 1741-SA) 1.No enforced DC/AC ratio.See tha compatibility calculator at httos t/enoha n oml - s upport/mo dule•compatibility. The 10 7X is required to support 96-cell modules. 2.Nominal voltage range can be extended beyond nominal if required by the utility. 3.Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. To learn more about Enphase offerings,visit enphase.com EN PHASE. To learn more about Enphase offerings,visit enphase.com u E N PHASE. 2tn8 Enphase 4 nerr.All rights reserved.All trademarks or brands:ised rare the proprrty of rnphase Enp•�y.Inc. 201811.19 f IRONRIDGE Flush Mount System XPRailsC XR10 Rail XR100 Rail XR1000 Rail Bonded Splices A low-profile mounting rail The ultimate residential A heavyweight mounting All rails use internal splices for regions with light snow. solar mounting rail. rail for commercial projects. for seamless connections. • 6'spanning capability • 8'spanning capability • 12'spanning capability Self-drilling screws • Moderate load capability • Heavy load capability • Extreme load capability • Varying versions for rails • Clear and black finish • Clear and black finish Clear anodized finish Forms secure bonding -- Clamps&Grounding O j UFOs Stopper Sleeves CAMO Grounding Lugs Universal Fastening Objects Snap onto the UFO to turn Bond modules to rails while Connect arrays to bond modules to rails. into a bonded end clamp, staying completely hidden. equipment ground. • Fully assembled&lubed • Bonds modules to rails • Universal end-cam clamp Low profile • Single, universal size • Sized to match modules Tool-less installation • Single tool installation • Clear and black finish • Clear and black finish • Fully assembled Mounts in any direction Built for solar's toughest roofs. Attachments O IronRidge builds the strongest mounting system for pitched roofs in solar. Every component has been tested to the limit and proven in extreme environments. FlashFoot2 Conduit Mount Slotted L-Feet Bonding Hardware Our rigorous approach has led to unique structural features,such as curved rails and reinforced flashings, and is also why our products are fully certified, code compliant and backed by a 25-year warranty. Strength Tested PE Certified All components evaluated for superior Pre-stamped engineering letters Flash and mount XR Rails Flash and mount conduit, Drop-in design for rapid rail Bond and attach XR Rails structural performance. available in most states. with superior waterproofing. strut,or junction boxes. attachment. to roof attachments. • Twist-on Cap eases install • Twist-on Cap eases install • Secure rail connections • T&Square Bolt options • Wind-driven rain tested Wind-driven rain tested • Slot for vertical adjusting • Nut uses 7/16"socket flClass A Fire Rating Design Assistant Mill and black finish • Secures 3/4"or 1"conduit Clear and black finish • Assembled and lubricated Certified to maintain the fire resistance ® Online software makes it simple to rating of the existing roof. create, share, and price projects. Resources Design Assistant NABCEP Certified Training UL 2703 Listed System 25-Year Warranty Go from rough layout to fully NABCEP 1 Earn free continuing education credits, Entire system and components meet Productsguaranteed to be free engineered system.For free. while learning more about our systems. y p Go to IronRidge.com/training Go to lronRidge.com/design newest effective UL 2703 standard. of impairing defects. . ter,. IRON RIDGE Class A Fire Rating Frequently Asked Questions What is a"module type"? What attachments and flashings are deemed compatible with Class A? The new UL1703 standard introduces the concept of a Background —■_ . PV module type, based on 4 construction parameters Attachments and their respective flashings are not All roofing products are tested and and 2 fire performance parameters.The purpose of constituents of the rating at this time.All code-compliant classified for their ability to resist fire. Test Setup this classification is to certify mounting systems without flashing methods are acceptable from a fire rating Solar Modules needing to test it with every module. standpoint. Recently, these fire resistance standards Solar modules are given a Type were expanded to include solar equipment classification based on their as part of the roof system. Specifically,this materials and construction. What roofing materials are covered? What mounting height is acceptable? requires the modules, mounting hardware Mounting System q All fire rated roofing materials are covered within this UL fire testing was performed with a gap of 5",which is and roof covering to be tested together as Mounting is tested as part of asystem that includes type-tested certification including composition shingle, clay and considered worst case in the standard.Therefore,the a system to ensure they achieve the same modules and fire-rated roof covering, cement tile, metal,and membrane roofs. rating is applicable to any module to roof gap. fire rating as the original roof covering. Roof Covering Roof covering products are given a These new requirements are being adopted Fire Class Rating of A,B or C based What if I have a Class C roof,but the jurisdiction Am I required to install skirting to meet the fire throughout on their tested fire resistance. the country in 2016. now requires Class A or B. code? Generally,older roofs will typically be"grandfathered No, IronRidge achieved a Class A fire rating without any Burning Brand Test in", and will not require re-roofing. However, if 50%or additional racking components. IronRidge Certification _>♦ more of the roofing material is replaced for the solar installation the code requirement will be enforced. What determines Fire Classification? IronRidge was the first company to receive a Class A Fire Rating—the highest Where is the new fire rating requirement code listed? Fire Classification refers to a fire-resistance rating system for roof covering materials based on their ability possible rating—from Intertek Group plc., a Nationally Recognized Testing Laboratory. — 2012 IBC: 1509.7.2 Fire classification. Rooftop to withstand fire exposure. A burning wooden block is placed on module as a fan blows at 12 mph. mounted photovoltaic systems shall have the same fire IronRidge Flush Mount and Tilt Mount Flame cannot be seen on underside of roof within 90 minutes. classification as the roof assembly required by Section Class A-effective against severe fire Class B-effective against moderate fir exposure xposure Systems were tested on sloped and flat — 1505. Class C-effective against light fire exposure roofs in accordance with the new UL 1703 Spread of Flame Test & UL 2703 test standards.The testing Where is a Class A Fire Rating required? What if the roof covering is not Class A rated? evaluated the system's ability to resist flame spread, burning material and The general requirement for roofing systems in the IBC structural to the roof.damage refers to a Class C fire rating. Class A or B is required for The IronRidge Class A rating will not diminish the fire g areas such as Wildland Urban Interface areas(WUI) and rating of the roof,whether Class A, B,or C. for very high fire severity areas. Many of these areas are Refer to the table below to determine the found throughout the western United States.California What tilts is the tilt mount system fire rated for? requirements for achieving a Class A Fire T has the most Class A and B roof fire rating requirements, Rating on your next project. Flame at southern edge of roof is aimed up the roof as a fan blows at 12 due to wild fire concerns. The tilt mount system is rated for 1 degrees and up and mph.The flame cannot spread 6 feet or more in 10 minutes. any roof to module gap, or mounting height. Are standard mid clamps covered? ■ ■ _ ��s.{ 1 _ Mid clamps and end clamps are considered part of the PV"system",and are covered in the certification. Flush Mount Any Slope Type 1, 2, &3 Class A More Resources — Tilt Mount Installation Manuals Engineering Certification Letters s 6 Degrees Type 1, 2, &3 Class A Visit our website for manuals that include UL • We offer complete engineering resources 2703 Listing and Fire Rating Classification. and pre-stamped certification letters. Go to IronRidge.com Go to IronRidge.com Class A rated PV systems can be installed on Class A,B,and C roofs. . l" 1IIl. liii, IPI. : . II. RT-MINI is suitable for Engineered to ASTM D 1761 (Standard Test Methods for Mechanical Fasteners in Wood) Components Dimensions in (mm) mounting any rail system RT2-00-MINIBK ° with a conventional L-Foot. �...� PAT PENDING o 0 ° 31/2 (90) 2 (5031 - MINI base : 20 ea. Rafter installation v z Screw : 40 ea. Extra RT-Butyl . 10 ea. RT-Butyl is Roof Tech's flexible flashing used in 550,000 residential PV systems for the last 20 years. It is the first PV mounting system with Flexible Flashing ____ certified by the ICC. Metal Flashing Retrofit Flexible Flashing Deck installation Dual bolt design M8 or 5/16" for L-Foot & 1 /4 for EMC Easy tapping 1/4" Hex Bolt o screw guide, upper channel Shedding water? 100/ Waterproof ICC ICC ESR-3575 ASTM2140 testing UV testing(7500 hrs.) M8 or 5/16" / / ICC ESR 3575 Flat lip for Hex Bolt _- I PV Cable, 'bottom channel Y Call Now for more details clips 858-935-6064 - P.E.Stamped Letters available at www.roof-tech.us/support 1 . / 1 - • • YRIDRY YA1m RY -R1D00Nw1 eon4d Sam* _ _ _ x I Ol ENOINEEPoNG NOTES..-____ _ : % Proper Flashing Placement A!warMF.r aa+w,0•i nr:I,!„ruM.q+am+v A,rmY+,+W'1 __ t• - A RAFTER OJSTALLATKWS-- ^`o+.'^*'9 N. k�:�1e•naoewrn _._ IRW1RIDfa'E xR RAIL m..epx,•"+"n:,px vmw Fan.„wx-y ra., .r 1a m.r+,«x...a'=xclx y anMeaa mmw-1,aa 1 A •6e00 cepen.ry 0*eo000 cep mwy 1I{un•e.O ADssw, SI4.d '5 v.+eva y'. J IROWi1DGE L-FOOT •HOdpala 006w Hea'.Y.D 01 - OD raPaean -F s,w 8808.OabDlV Vafl fl le•.ac,amr,a:a _. .-•'-_ . . J _ •tw.rd u.n,e-..n -ew.a"•I ba<M noxn •ees a,mray 51 ,m em,Dm Fexsaa , 1}@7 TYPICAL 886511)KiOtILY.SELF-FIwSHW6. BOLTS FLANGE NUr 1.-.�...� ^ 1 _ SOUR ROOF ATTACHMENT Wn/f OPTPGNAL• (TORON TO IQ __ s l REI)UNO/WT WATERMtOOFINGMPEARANCE INsBWTNMUMI O j MAY VARY-0BNSORRLVOYE. RTLEIASLANT UFOs mgiP.,.Me,n CANTO f+ueMiq L.,Ix - • .._ . �.. MM4 BASE `� 1 B 00- S f _ (WATERPRDOOOFING) — — ----------— IRONRIDGE PV RAIL GENERIC INSTALLATION PLAN 3yt3.�w ® EXL5TMJGRO LRD-ASPHALT 1. THIS"PAPER"PLAN IS INTENDED TO PROVIDE THE ESSENTIAL INFORMATION # _ _ f 1 �L `SMLE � � �C NEEDED BY AHJ(AUTHORITY HAVING JURISDICTION AKA BUILDING DEPARTMENT)AND c sY Fase•g Cgcm s>pD mm•uFommm eDx vawaamFd•d e c«f a+,.•m SHEATHING "* INSTALLERS.CONTRACTOR SHALL INDICATE TO AHJ WHICH METHOD HE/SHE WILL USE. DonD Dwwx m.a»s Dm a uw,d.a ow namD. nx+F,a�aamlen"ana.,. aD,. _wo,aa yr•=w.� «awn •B a.-..nAxa,a. n ..+MDR.,• rn -s ++a (2)swwsN000Sc00WS 2. THIS PLAN SHALL BE USED SOLELY FOR PROJECTS IN AREAS WHERE WIND SPEED IS - •s"aD,4m�mDwm1 9 COMPU S REDUNDIN NTWPTMENT Vult 170 MPH OR LESS.INSTALLATIONS IN HIGHER WIND AREAS SHALL REQUIRE SELLMe1.rID I»aG Mvrt `w"»"d"a`,*,a5A r"-">s.`x"°" »'�`R""°`«"" WTiRE°uuuwrY TaacEr g• -' qq SITE-SPECIFIC ENGINEERING. FFASe1HRO INOA TTAOMIENTPNOTOS �_ G . !1 3. THIS PLAN OFFERS THREE INSTALLATION METHODS. 7 F44KDp3 Cw&A+1Aan1 Eb1Yd L-FM 80808lHard'"a1e � -J - 1 -- OSBIPLYWOOO.ONLY CONNECTION .A a.FRAMING METHOD.SEE DRAWINGS. 4 S ATTERN PLAN b.SHEATHING METHOD.SEE DRAWINGs. CREW P 12 }— `" •� T4N.MAX.TO TOP OFRAIL---- C. STANDING SEAM/PBR(PURLIN-BEARING)METAL ROOF.USE CLAMP/BRACKET OF .. y � r y I /� AT RAFTER INSTALLATIONS/- CHOICE; 1,? P l7 ( ACE.http://www.pmcind.com/aceclamp/ r„y, 1tl rxW xR Ha'b fW1R aro rre„•f xwAnt L\co+n b+g-br.tA.a arA aM a0xn%R pan ,Y 1 R2ONRx1GE FOOT .a"+P«A..+'�*'A^•^ ,",A.n,V+poDe.".x ,a,. a,.xx.aao»>Wx» � ry ' - - / �$.1�� � 5-5.https://www.s-S.com/products/clamps-brackets/s-5-u-clamps/ I— C.—xyax Tm!-0nc Dah551'Salvaa s.nxa n::arr+c"IDs rf SQ%e Bob. j...-` / —ss304 Y1 F-ta IEx w-mss o � � BDLTaFLANGENur https://www.s-5.com/products/clamps-brackets/proteabracket/ •WnEArva»,»n NH1N1 W.+04n' ..n, SK:I[.ren.:s r0•+'r9 Nu uiu•a t:,b'aacxW - (TORQUE TO140 L»»aro er ,•.•A wH..+,.,.+ _ Gxs•am xm nr.,+ •ww.,mnrdraw"..Aw I --- j--- IN.LBM"mu.) m .mn.0.lxm 4. CONTRACTORSHALL MAKE CLEAR TO AHJ WHICH INSTALLATION DETAILS WILL BE FLORIDA ROOF ATTACHMENT SPACING(FEET):ROOF HEIGHT<30-FT 8 ROOF SLOPE C 30' 23/16 8a PftOTEA BRACKET L-i RTIEI MOGNT Lrn Bomi USED. WINO(MPH) P21 PZ2 PZ3 IRONRIDGE RAIL MINIeA M Roersealant 5. SOLAR EQUIPMENT ADDS LESS THAN 4-PSF GRAVITY LOAD TO STRUCTURE. 110 8 6 4 XR-10 t` 1 11116 ► _/ ///---BUm.SPACER lam 6. THERE SHALL BE A PV MODULE TO RAIL MOUNTING CLAMP AT EVERY MODULE/RAIL 3{� �, M'ATERPROOFlNG) 5A R®F CROSSING POINT WITH MINIMUM 4 CLAMPS PER MODULE. ADJOINING MODULES SHALL 130 8 6 2 XR-10 35/16 ` *R.mm..Dd.LL Prodtst SHARE MID CLAMPS.MODULES MAYBE LANDSCAPE OR PORTRAIT AT CONTRACTOR 130 6 4 2 XR-100 a.--.L= .1�: I _.. �..�.t_ sN 'H.�y:2MR,sea,M�.Dw OPTION. 140 6 4 2 XR-100 5l16� MINIMUM ACE CLAMP EnISTwGROLLED-ASPKALT •G.Dab'B$84(ff:.eU 3-INCH u OR wMPOSREASPHALT •8.9m:7Lmn.hth.RDDr 7. THERE SHALL BE A MINIMUM OF TWO RAILS UNDER EACH PV MODULE. 150 6 4 2 XR-100 SHINGLE ROOF •BDe:39a DBeHL) THREAD - . : 8, RAILS SHALL NOT CANTILEVER BEYOND OUTSIDE OF END ROOF ATTACHMENT BY _( 160 6 4 2 XR-1000 EMBEDMENT 55aoesoDxD.xe06'e TbpIndurtdalEdeBl.terSM 00 MORE THAN 1 FOOT 170 4 4 XR-1000 `^--"� " .:. WOW SCREWS •Chem Wlt:Mi ®IROt♦RIDGE FIASHFOOTT APPROVEDMETALROOFCIAMPS&BRhCIDiT __-... -1 9. RAILS SHALL ALTERNATELY ATTACH TO ROOFTHRU IRONRIDGE L-FEET AND ROOF ROOF TECH RT MINI INSTALLATIONDETAILS 1B0 it „".:,� sratEwvnTTERN I RAFTER Oz TECH RT MINI ROOF ATTACHMENT ASSEMBLY AS SHOWN IN FIGURE 02.CONTRACTOR O , ,i GONNECf1011 SGIE:MI6 rRON1TI NE WERooFM9DNrsrsTEMcoMPONrs FLAN - SHALL ENSURE THATTHE EXISTING ROOFING,ROOF SHEATHING,RAFTERS/TRUSSES AND >3 1086 sea OTHER STRUCTURAL MEMBERS CAN SUPPORT THE ARRAY UNDER ASCE 7-14 CODE LOADING CONDITIONS. 10. L-FEET REQUIRE FLASHINGS WHICH CAN BERT MINI BUTYL TAPE(FIG.02)OR MIN 4" x 8"x 26 GA.GALV,0.032 ALUM,OR INDUSTRY STANDARD OEM FLASHINGS OVER GROUNDING PV MODULE GROUNDING Pv*RA -C MIDANP ATTACHMENTS LAGGED INTO ROOF FRAMING OR SHEATHING-ONLY(FIG.02),E.G.SOLAR MID-CLAMP MID-CLAMP MOUNT,IRONRIDGE FLASHFOOT 1 OR 2,OTHER ACCEPTABLE TO AHJ. PV RAIL EXI - 3/8 1683/4 HEX HEAD BOLT Pv RAIL 11. CONTRACTOR SHALL REFER TO ASCE7-14 WIND PRESSURE ZONES INSTRUCTIONS PV RAIL 3/8 ROOF TI3/8-26 FLANGE NUT HEX HEAD BOLT D&RAIL,C-C ROOF ATTACHMENTSPAN.THE IRONRIDGE TABLE T 13)FOR APPROPRIATE WIND SPEED, 3/8-16 FLANGE NUT PV MODULE EXssr.DECKINGROOF 12. ALL FLESHINGS SI IALL BC INSTALLED IN A GENEROUS BCD OF FLORIDA PRODUCT L-FOOT SERRATED L ON ROOF CONTROL APPROVED(PCA)POLYURETHANE ROOF SEALANT. ROOFROOF MOUNT 13. LONG L-FEET&/OR STANDOFFS ARE PERMITTED AS NEEDED FOR ROOF CLEARANCE. TILE 55 METAL PLATE, SQUARE OR ROUND ROOF SHEATHING SEE NOTE#10 -RLLCAVfrYWITH WATER ROOFSTAANDOWATE1 FINGM EXISTING FRAMING-XISTINGASPHALT SHEATHING -EXISTING OR LOTIHSONIWSRC CODE: FBC 2017 (6TH EDITION) SHINGLE ROOF FOAM L-FOOT . - P-1 OR EQUAL TH 5/16'CRS.LAG W/3" READ EMBEDMENT FLORIDA PRODUCT FRAMING ADHESIVE I'BEYOND BOTTOM OF DECK POLYURETHANE CAULK IN tILOCIGNG,101ST,ORTRl155 FLORIDA BUILDING CODE FRAMING-METAL ROOF AITACHLffM; 4 MINIMUM APPROVED SEALANT ^#12 X 2-INCH, EXISTING FOUR#14 CRS ■ 1BMRELT EROOFATTADHME rt V; ®ROOFCOVERMIGCOIADBESHWGLE.TNE.ORSMGLEPLY. SCREW51"BEYOND "ALE`"" - /+ �) 160mph SS,SMS UNDERLAYMENT "" ;�I BOTTOM OFDECK YYIND- DESIGNED FOR VUIt- ®SHINGLE,TIE.SINGLE FLY FLAT TILE ROOF ATTACHMENT _.«• - RISK II EXPOSURE B. SCALE:Iu1S SUIE:NT6 810 ) 3/6-16 x 3/4 PV RAIL - k FLASHFDOT 2 f 3/8-16 k! �i'• �I" N— �i.- --'—' FLANGE SEE.FIGURE II -_ , ,�C `,_ �.y.,__.• PV ' FkIRDof HlcRndil•<B52T'I EXISTING _ MODULE I '• >" : � I CERTIFY THAT THE SHEETING AND FRAMING OF THIS `SPHALT =" �` = } =I- '� STRUCTURE WILL SAFELY ACCOMMODATE CALCULATE SHINGLE 1 - �•" °" •. ROOF _ _ � 1� -:'� ,:.yl >� _ '„ WWD UPLIFT AND LATERAL FORCES '' ss PROTEA ` �+-"�'Y - -_ AND EQUIPMENT DEAD LOADS.THIS IS ATTESTED TO BY MY SIGNATURE AND SEAL ON THIS DRAWING RONF -EXISTING GableRWL.1s7' SHEATHING FRAMING METAL �� ' AT THE LOWER RIGHT BOTTOM. 5/16"CRS.LAG W/3" 6MM X 25 MM BI-7 \ / PER PROFILE PZ2:ROOF INTERIOR THREAD EMBEDMENT IN METAL SHEET SCREW .•./a P22:ROOF PERIMETER ER BLOCKING,JOIST,OR TRUSS (MIN.3'&LEAST OF 40%EASE HEIGHT OR 10%BUILDING LAW. PZ3:OUTSIDE CORNERS FLASHFOOT 2 SHINGLE ROOF ATTACHMENT S5 PROTEA BRACKET METAL ROOF ATTACHMENT L&W=PZ2..=PZ2 WIDTH..IT=EAVE HEIGHT. 05 61515:N1i SCALE:016 ASCE 7.10 COMPONENTS CLAWING WINDPRESSURE ZONES. � sTA1E:Ins• Permit manager: Description: Solar Panel Details * Widup, P.E. SHEET: Bay Area Project Solutions, LLC Location: FLORIDA 39905 Grays Airport Road 1501 S. Pinellas Ave, Suite N, BAY AREA Tarpon Springs, FL 34689 Date: 12/31/2019 Lady Lake, FL 32159 ,')\ TV-S M Phone:727-940-3256 Revision Date: P.E. No. 60302 r