Loading...
HomeMy WebLinkAbout20-982 . m o-��- T City of Zephyrhills .;p``PERMITNUMBER ; 5335 Eighth Street Zephyrhills, FL 33542 BGC-000982-2020 *r Phone: (813)780-0020 Fax: (813)780-0021 Issue Date: 10/29/2020 Permit Type: Building General (Commercial) Property-Number Street Address 35 25 21 005A 00000 1140 MIS See Description Camden Avenue Owner.lnformation Permit Information ,. , Contractorinformatiowr Name: DUKE ENERGY Permit Type:Building General(Commercial) Contractor: DUKE ENERGY Class of Work:Right of Way Temporary Use Address: 4427 Pet Ln STE 101 Building Valuation: LUTZ,FL 33559 Electrical Valuation: ,'� Phone: Mechanical Valuation: v Plumbing Valuation: Total Valuation:$0.00 Total Fees: Amount Paid: Date Paid: Pro�ec#kDescription._ _ MIS SEE DESCRIPTION 38609 CAMDEN AVE A lication Fees ,Fu REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each subsequent reinspection. Notice: In addition to the requirements of this permit,there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permit required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner:Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing, consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications add fee Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. ,q1QgL*y*-r- CONTRACTOR SIGNATURE PE IT OFFICE PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER Right of Way Use Permit CITY OF ZEPHYRHILLS - BUILDING DEPARTMENT RIGHT-OF-WAY USE PERMIT DATE: 10/15/2020 PERMIT# i No construction under ground or above ground of any facility shall be accomplished on any City Rights of Way without written approval from the City Building Department. Any application for approval of construction operations on any City owned Rights of Way shall furnish a detailed drawing showing the complete scope of the proposed work in triplicate to the office of the Building Official for approval prior to the commencement of any work. A copy of this permit is to be kept readily available at the site of the work at all times. PARCEL I.D. # 35-25-21-005A-00000-1140 CITY Zephyrhills ROAD 38609 Camden Ave. Zephyhills, FL 33540 DATE 4/2/2020 LOCATION (Legal Description) ALPHA VILLAGE ESTATES PHASE 2 PB 23 PGS 8-9 LOT 114 Permission is hereby granted to Lisa Wood of Duke Energy 4427 Pet Lane ste 101, Lutz FL, 33559 for the construction and maintenance of: Replace 150 feet of 1/0 primary cable from transfomer to transfomer, directional bore . ` I i subject to the following conditions: 1. The construction and maintenance of such utility shall not interfere with the property and rights of a prior occupant. 2. All work shall be done in keeping with the standards of the City Streets Department and under the supervision of the City Building Official, who will be notified at least one day prior to commencement of construction. 3. All materials and equipment shall be subject to inspection by the City Building Official. 4. During construction all safety regulations of the Department of Transportation shall be observed and the City shall be relieved of all responsibility from damage of any nature arising from this permit. Subject,to the same terms and conditions, the permit holder may take such safety measures, including placing and display of caution signs, as it may deem necessary in conduct of construction and maintenance work hereunder. It is the responsibility of the permittee to ???? 5. All private and all City properly shall be restored to its original condition as far as practical in the opinion of the City Building Official. 6. All underground crossing installations shall be laid at such depth as may be specified by the City Building Official. 7. The sketch covering the details of this installation shall be made a part of this permit. This permit is granted with the ,understanding that the applicant has notified all other utility users in the area covered by the permit and takes full responsibility for any damage incurred by prior installations as a result of his operations in order that they may safe guard their interests. 8. It is expressly stipulated that this permit is a license for permissive use only and that the placing of facilities upon public property pursuant to this permit shall not operate to create or to vest any property right in said holder. 9. Whenever the City decides to further exploit the City Rights of Way, any or all said poles, wires, pipes, cables, or other facilities and appurtenances authorized hereunder, shall be immediately removed from said Rights of Way, or reset or relocated thereon as required by the City Building Official at the expense of the holder of this permit. 10. The holder shall save and keep the City harmless from any and all damages, claims, or injuries that may occur by reason of the construction, maintenance, and operation of said facility. 11. The holder shall complete the requested work within days or this permit shall become null and void. In the event the work requested is not completed upon the expiration date of this permit, the City shall have the right to complete such work and to charge the holder of the permit for all costs incurred in completing said work. 12. The holder shall post a cash or surety bond with the City Manager in the sum of$ dollars to guarantee performance of the obligations herein, and to guarantee maintenance of the right-of-way described herein for a period of one (1) year following completion of the requested installation. In the event a surety bond is posted, the surety bond shall be made payable to the City and shall obligate the surety to hold the City harmless in the event the holder of this permit should fail to meet any of its obligations hereunder. The bond shall also indemnify the City for all court costs and reasonable attorneys fees in the event legal action is required to collect on said bond. SUBMITTED BY: (Permittee) Lisa Wood Duke Energy Signature &Title Address 4427 Pet Lane ste 101, Lutz, FL, 33559 coastalpermitting@duke-energy.com APPROVED BY: CITY OF ZEPHYRHILLS Building Official Date: Utilities Supervisor 4--- Date: 2® oe. �A � Public Wor 'ENO OPEN E S06 Aa blS?L me-d Date: City Manager Date: USP: BREAKER C344 Safety Reminders 1 Adverse Conditions p—e o y • P1:28.265249,-83.177675 r CAUTION: SAFETYFirst � -VEGETATION NEAR P1 D PExsoxAl Alo.—anm D Al—caaxc sAyflv -WOODEN FENCE NEAR P2 ►IuvAxo xeeoewnox REMEMBER:Work zone area conditions may have changed for this jobs Everyone is responsible for verifying the above safety information is correct prior to any work being performed each day. 11427400529040 PAD-1 14 1700529040 OPEN ACCESS _ R/I-ELBOWS 1 _ ................. e. 1 I 38609 I � ti� p y »(903;-30-Nt�ne _— PAD-11424.00529040 LdM POLE-27C3;i(�8-30-NcJat� lVl ...: CAMDEN AVE S1-150' 0_Np ic R-#2 AL UG(C I-1/0 AL UG(C) I-CONDUIT-3"-IIDPE T 0 � SCOPE OF WORK: 35610 � ` - - W workoderrvumoer 34724126 REPLACE 150 FT OF.1/0 AL UG PRIMARY CABLE FROM J II J p Customer/Contact TRANSFORMER 11427500528850 TO TRANSFORMER 11427400529040 A ` ConW Phone Job SIte Address 38609 CAMDEN AVE NEWI P. CABLE TO BE INSTALLED VIA CONDUIT s_ J 1 cn, ZEPHYRHILLS aD- e� .�u - a � u I�� county PASCO PROJECT LEAD:ALBERTO CRUZ P 427500528850 Mete,zip FL,33540 PHONE:321-316-4846 EXT.1115 Y; PAD- Designer ALBERTO CRUZ - EMAIL:ALBERTO.CRUZ@DUKE-ENERGY.COM I R/I�IJ BOWSSED ESS D.eignerrnono 321-its asas PI CONSTRUCTION NOTES: C1non e) C344 -PI IS ACCESSIBLE BY TRUCK FROM 38609 CAMDEN AVE LOCATE P1 AT SOUTH-EAST CIO PROPERTY VE PdmxryVc egp tz.a7n.2 kV -DISTANCE FROM EOP TO PI IS APPROX 19 FT TRELL15 A P®maeamwd Ve3_N4_ -LIGHT TRAFFIC AREA,MOT IS REQUIRED PenneTyp-. P-1 TypolNo._ - P2 CONSTRUCTION NOTES: _� Purmll TypoMo. -P2 IS ACCESSIBLE BY FOOT FROM 38610 CAMDEN AVE ,{, PmNr TypaMe., LOCATE P2 AT SOUTH-EAST C/O PROPERTY DUKE -P2 IS IN BACKLOT,MOT NOT REQUIRED POLE 2768962-3o-,Nonc 1 45ENERGY sla-1-6o' Legend for Construction Prints 0 Existing Overhead Install Overhead R/W C/L R IW Transformer Transformer 60' Existing Underground ' Install Underground Transformer � � Transformer I I I P Install Pedestal Install Recloser I I I i I - Existing Down Guy ) Install Down Guy FRONT YARD BACKLOT I O Existing Pole Install New Pole I I I Existing Fuse � I Install Fuse EOP EOP I Overhead Cable Closed Switch 17' 26' 17' I I GENERAL CONSTRUCTION NOTES - I DUKE ENERGYTO RESTORE RIGHTOF WAYTO EQUAL OR BETTERTHAN EXISTING CONDITION. P1 i P2 * TO AVOID CONFLICTS,CONTRACTOR WILL COORDINATE DEPTH OF UNDERGROUND APPROX.19' FACILITIES WITH THE MUNICIPALITY INSPECTOR PRIORTO BORES BEING INSTALLED. I TFMR I I I TFMR I I * MINIMUM DEPTH OF CABLE IN CONDUIT IS 36INCHES BELOW GRADE.THREE FEETOF S'EASEMENT S'SDWK 12'GRASS 12'GRASS S'SDWK S'EASEMENT SEPARATION FROM EXISTING UTILITIES AND STORM WATER/SEWERS REQUIRED. I I * ALL PULL BOX LIDS SHALL BETRAFFIC RATED WHEN INSTALLED WITHIN THE RIGHT OF WAY. I I CONTRACTOR SHALL MAINTAIN AN UNINTERRUPTED ACCESS TO ALL DRIVEWAYS, I SIDEWALKS AND SIDE STREETS ALWAYS,UNLESS OTHERWISE APPROVED ON THE MOT I I I PERMIT. I * A SEPARATE PERMITWILL BE REQUIRED FOR ANY SUBSURFACE TEST HOLES UNDER I PAVEMENT. I REPLACE 150'OF 1/0 AL UG PRIMARY CABLE IN 3" * DUKE ENERGYTO MAINTAIN 3 FEETMINIMUM COVER. I TYPICAL CROSS SECTION HDPE CONDUIT VIA DIRECTIONAL BORE FROM TRANSFORMER(P1)LOCATED IN 5'PLATTED I • ALLOTHER RIGHT OF WAY USERS AND MUNICIPALITIES IN THE IMMEDIATE VICINITY OF THE FOR CAMDEN AVE. EASEMENT CROSSING CAMDEN AVE TO PROPOSED CONSTRUCTION/INSTALLATION HAVE BEEN NOTIFIED IN WRITING. I LOOKING EAST TRANSFORMER(P2)LOCATED IN 5'PLATTED I EASEMENT IN BACK LOT I MINIMUM DEPTH OF CABLE AND CONDUIT UNDER SWALES AND DITCHES IS 3 FEET BELOW THE BOTTOM OF THE SWALES AND DITCHES. I I I MINIMUM HEIGHTOF OVERHEAD WIRES AND CABLE IS 18 FEETOVER ROADWAYS AND 16 FEET OVER DRIVEWAYS. � I **BEFORE DIGGING,CALL SUNSHINE @ 1(800)432-7770** EXIST UTILITY ABBREVIATIONS: PROJECT LOCATION: WO#34724126 f.�DUKE S-SEWER I R-RECLAIMED WATER I W-POTABLEWATER I G-GAS I E-ELECTRIC I CAMDEN AVE DRAWN: ENERGY. EXIST UTILITIES @ ASSUMED 36"MIN DEPTH,LOCATIONS ARE APPROXMATE C-COMMUNICATIONS,ALARM,SIGNAL,CABLES OR CONDUIT *NOT TO SCALE DATE:04/01/20 r - "i S-T-A uu pi _ 07- W7 jfl) se aj •.1iRr.3 '-.+4 A.: k _ �r, SYMBOLS: ® Work Area • Channelizing Device(See Index 102-600) [b Work Zone Sign Buffer Space 250' C B A LT' Flagger See �j Lane Identification+Direction of Traffic Table 1 D ROAD PREPARED �qQ p E WORN T06TOP nn AIIFAp AHEAD ,n a a b Work Area b Tangent Device Spacing(See Table 1) ROAD ONEOUE BE • WORK aRewD t�Dy iosmm n Taper Length D 50,To 100' x May Be omitted if ROAD WORK AHEAD sign is installed upstream within the project limits. A B C WITHOUT TEMPORARY RAISED RUMBLE STRIPS GENERAL NOTES: 4.When a side road intersects the highway within the TTC zone,place TABLE I and the following sheets: 1.Special Conditions may be required in accordance with these notes additional TTC devices in accordance with other applicable TCZ Indexes. DEVICE SPACING S.The two channelizing devices directly in front of the work area may be Maximum Spacing Distance A.Railroad Crossings: p clog Maximum Spacing of omitted provided vehicles in the work area have high-intensity rotating, Between a.If an active railroad crossing is extend eBcloser to the Work Area than Posted of Canes ke Type l or Type 11 Buller the queue length plus 300 feet,extend the Buffer Space as shown on flashing,oscillating,or strobe lights operating. Speed Tubular Markers Barricades/Panels/Drums Signs Space Sheet 3. p b.If the queuing of vehicles across an active railroad crossing cannot be 6.When Buffer Spare cannot be attained due[o geometric constraints,use q 9 9 the greatest attainable length,not less than 200 ft,for posted speeds On a On a On a On a avoided,provide a uniformed[raflic control officer or flagger a[the greater than 25 mph. Taper Tan en[ Taper Tangent A 8 C D highway-rall grade crossing to prevent vehicles from stopping within 25 20' SO 20' S0' 20O 200 200' 700' 155' thedew highway frail grade crossing, even if automatic[rain warning 7,ROAD WORK AHEAD and the BE PREPARED TO STOP signs may be omitted if devices are in place. 30 20' 50' 20' 50' 2001 200' 200' 100' 200' B.If the Work Area encroaches on the Centerline,use the Layout for all 01 the following conditions are me[: Temporary Lane Shift to Shoulder on Sheet 3 only if the Existing 35 20' S0' 20 50, 200' 200' 200' 100' 250' Paved Shoulder width is sufficient to provide for an 11'lane A.Work operations are 60 minutes or less. 40 20' 50, 20' 50' 200' 200' 200' 700' 305' between the Work Area and the Edge of Existing Paved Shoulder. B.Speed limit is 45 mph or less. Reduce the posted speed when appropriate. C.There are no sight obstructions to vehicles approaching the work area for 45 20' 50' 20' 50, 350' 350' 350' 17S 360' a distance equal to the Buffer Space shown in Table 1. 50 20' 50' 20' 106' 500' SO& 50U 250' 425' 2.Temporary Raised Rumble Strips: D.Vehicles in the wort area have high-intensity,rotating.flashing,oscillating, or strobe lights operating. 55 20 50' 20 100' 2640' 1500 1000' 500' 495' A.Use when both of the following conditions are met concurrently: E.Volume and complexity of the roadway has been considered. 60 20' 50' 20' too, 1640' 1500' 1000' 500' 570' a. Existing Posted Speed is 55 mph or greater; F.If a railroad crossing is present,vehicles will not queue across rail tracks. 65 20' 50' 20' 100' 2640' 1500 1000' S00' 645' b.Work duration is greater than 60 minutes. G.AFADs are not in use. B.Use a consistent Strip color throughout the work zone. 70 29 50' 20' 100' 2640' I500' 1000' 500' 730' C.Place each Rumble Strip Set transversely across the lane at locations B.See Index 102-600 for general TCZ requirements and additional information. shown. 9.Automated Flagger Assistance Devices(AFADs)may be used in accordance throughooutut work zone. D.Use Op[ 1 or Option 2 as shown on Sheet 2.Use only one option with Specifications Section 102,990 and the APL vendor drawings. 3.Additional one-way control may be provided by the following means: CONDITIONS A.Fla parrying vehicle: WHERE ANY VEHICLE,EQUIPMENT, B.Official vehicle; C.Pilot vehicles; WORKERS OR THEIR ACTIVITIES D.Traffic signals. ENCROACH THE AREA BETWEEN When flaggers are the sole means of one-way control,the flaggers THE CENTERLINE AND A LINE 2' must be in sight of each other or in direct communication at all times. OUTSIDE THE EDGE OF TRAVEL WAY. Q LAST 2 DESCRIPTION: FY 2019-20 INDEX SHEET REVISION FDOT TWO-LANE, TWO-WAY, H/01/17 W O STANDARD PLANS WORK WITH INTHETRAVELWAY 102-603 1 of 3 SYMBOLS: ® work Area Channelizing DeUlte(See lndex 102-600) C B A [p Work Zone Sign IT' Flagger N� CJ Lane Identification+Direction of Traffic ■ — PREPPRED oNE UNE SPAY RmADIF ROAD II TOSiOP � WYOUR E1RVb WY)RK AXFAD UNE AXFAD AHEAD Temporary Raised Rumble Strip Set (See GENERAL NOTE 2) D 250' 250' 250' 0 41 41 0 41 a a Work Area 250' 250' 250' D Temporary Raised Rumble Strip Set (See GENERAL NOTE 2) ROAD RUMBLE SPAY ONE UNE BE WORN biNPb INYOUR RO/D FREPMED �� AHEAD AHEM IANE gNEM TO bTOP A B C See Sheet I For Layout *May Be omitted if ROAD WORK AHEAD sign is installed upstream within the project limits. WITH TEMPORARY RAISED RUMBLE STRIPS (When Required See GENERAL NOTE 2) v e \e pD\V\SVP� v, —�pd`ev s'Oy'PP` CSYt�F\n ��a. —�'Od a's�pss z, pemD�r9 S aPe 'r`r la \oee�p e s°4j PP r�r Df sAe%o ed Eoel PJl ypl r'sAa r ely\o\dp o\VmSYtiP �hr. �DDe 1\``e) EdO Je\ Edge "Ole Ceo\\odd e ly / cye\\o1le l REMOVABLE POLYMER STRIPING TAPE MOLDED ENGINEERED POLYMER SET RUMBLE STRIP SET RUMBLE STRIP SET OPTION - 1 OPTION - 2 TEMPORARY RAISED RUMBLE STRIPS LAST 0 DESCRIPTION: REVISION : FDOn FY 2019-20 TWO-LANE, TWO-WAY fNDEX SHEET 71101117 w ��- STANDARD PLANS WORK WITHIN THETRAVELWAY 102-603 2 of 3 C Taper Length Extended Buffer Space 250' C Cont.Layout 50'To 100' oo xor Con[.Layout F srov ox Ta�CKS <= X x ------------------- �•Mork arear b Y R/15'Clear(Typ.,Each Side) •/////////� R Tracks 50'To 100, Device Spacing(See Table 1) Tangent Taper Length TEMPORARY RAILROAD CROSSING BUFFER SPACE EXTENSION Shifted Lane(I P Min) C Taper Length Buffer Space(See Table 1) Buffer Space(See Table 1) 375' C Cont. 50'To 100' r � I Layout /�Edge Of Existing Paved Shoulder(Typ.) Layout b •Nyork Areai b Edge Of Existing Travel Lane(Typ.) •jj�/ Taper Length Device Spacing(See Table 1) Tangent 50'To 100' TEMPORARY LANE SHIFT TO SHOULDER WHEN WORK AREA ENCROACHES ON THE CENTERLINE SPECIAL CONDITIONS Cross Reference: 1.See General Note 1,Sheet I for more Information. R SPECIAL CONDITIONS LAST DESCRIPTION: REVISION ti FDOT� FY 2019-20 TWO-LANE, TWO-WAY INDEX SHEET 11101117 �- STANDARD PLANS WORK WITH 'b HE T R.AVE]L WAY 102-603 3 of 3 SYMBOLS GENERAL NOTES: I ® Work Area 1.When encroaching work requires a sidewalk closure for 60 6.Provide a cross-slope with a maximum value of 0.02 for all temporary walkways. minutes or greater,provide an alternate pedestrian route. ■ Channelizing Device 7.Maintain temporary walkway surfaces and ramps that are stable,firm,slip-resistant, [p 2.For spacing of vehicular Channelizing Devices,see applicable and free of any obstructions or hazards such as holes,debris,mud,construction Work Zone Sign vehicular temporary traffic control Indexes. equipment,and stored material. CR Required Locations for Either Temporary 3.Cover or deactivate pedestrian traffic signal display(s)controlling R.Remove temporary walkways immediate) after reopening of the sidewalk,unless Or Permanent Curb Ramps. P 99 P Y Y Y P 9 closed crosswalks. otherwise noted in the plans. b Lane Identification+Direction of Traffic Pedestrian Longitudinal Channelizing Device(LCD)with 4.For post mounted signs located near or adjacent to a sidewalk, 9.Meet the requirements of Index 522-002 for temporary curb ramps. f Mounted Work Zone Sign or separate Work Zone Sign maintain a minimum 7'clearance from the bottom of the sign panel to the surface of the sidewalk. 10.Place pedestrian longitudinal channelizing device(s)across the full width of the H Pedestrian Longitudinal Channelizing Device(LCD) closed sidewalk.For temporary walkways,similar to the Sidewalk Diversion, ® Temporary Sidewalk 5.Provide a 5'wide temporary walkway,except where space restrictions place LCDs to delineate both sides of the temporary walkway. warrant a minimum width of 4'.Provide a 5'x 5'passing space for temporary walkways less than 5'in width at intervals not to 11.For sidewalk diversions,ensure that there is sufficient RYW for placement of exceed 2001. temporary sidewalk and pedestrian longitudinal channelizing devices. a _ o CR b �01 IQI Q Q [R Q II 3d3H SSOHO g I D! yjt{y 03SO10 NNM301S g K�I aT 1 O3SOlrJ w DETOUR 41- ■ � AtlMNNM NldM301S o NVINL5303d `c^ v, `L U� v, ROAD 43SOlO � Sc �tr) a AHEAD �U U �] �] SIDEWALK CLOSED PEDESTRIAN LPW a a WALKWAY � b CR N ¢ ■ � 8 ~ DETOUR Q i:in�O SIDEWA`.=CLOD 2{f10130 an O USE OTHER SIDE CR .@[ ❑ j ROAD ROAD WORK WORK $ ❑ tg ROAD ip o AHEAD AHEAD CROSSWALK CLOSURE AND SIDEWALK DETOUR SIDEWALK DIVERSION PEDESTRIAN DETOUR LAST 2O DESCRIPTION: FY 2019-20 IN SHEET REVISION FOOT PEDESTRUAN CONTROL FOR CLOSURE OF SH DEWALKS 11101117 w �— STANDARD PLANS 102-660 1 Of 1 o: Right ®f Way Use Permit CITY OF ZEPHYRHILLS - BUILDING DEPARTMENT RIGHT-OF-WAY USE PERMIT DATE: 10/15/2020j PERMIT# No construction under ground or above ground of any facility shall be accomplished on any City Rights of Way without written approval from the City Building Department. Any application for approval of construction operations on any City owned Rights of Way shall furnish a detailed drawing showing the complete scope of the proposed work in triplicate to the office of the Building Official for approval prior to the commencement of any work. A copy of this permit is to be kept readily available at the site of the work at all times. PARCEL I.D. # 35-25-21-005A-00000-1140 CITY Zephyrhills ROAD 38609 Camden Ave. Zephyhills, FL 3'1,540 DATE 4/2/2020 LOCATION (Legal Description) ALPHA VILLAGE ESTATES PHASE 2 PB 23 PGS 8-9 LOT 114 Permission is hereby granted to Lisa Wood of Duke Energy 4427 Pet Lane ste 101, Lutz FL, 33559 for the construction and maintenance of: Replace 150 feet of 1/0 primary cable from transfomer to transfomer, directional bore subject to the following conditions: 1. The construction and maintenance of such utility shall not interfere with the property and rights of a prior occupant. 2. All work shall be done in keeping with the standards of the City Streets Department and under the supervision of the City Building Official, who will be notified at least one day prior to commencement of construction. 3. All materials and equipment shall be subject to inspection by the City Building Official. 4. During construction all safety regulations of the Department of Transportation shall be observed and the City shall be relieved of all responsibility from damage of any nature arising from this permit. Subject to the same terms and conditions, the permit holder may take such safety measures, including placing and display of caution signs, as it may deem necessary in conduct of construction and maintenance work hereunder. It is the responsibility of the permittee to ???? 5. All private and all City properly shall be restored to its original condition as far as practical in the opinion of the City Building Official. 6. All underground crossing installations shall be laid at such depth as may be specified by the City Building Official. 7. The sketch covering the details of this installation shall be made a part of this permit. This permit is granted with the understanding that the applicant has notified all other utility users in,the area covered by the permit and takes full responsibility for any damage incurred by prior installations as a result of his operations in order that they may safe guard their interests. 8. It is expressly stipulated that this permit is a license for permissive use only and that the placing of facilities upon public property pursuant to this permit shall not operate to create or to vest any property right in said holder. 9. Whenever the City decides to further exploit the City Rights of Way, any or all said poles, wires, pipes, cables, or other facilities and appurtenances authorized hereunder, shall be immediately removed from said Rights of Way, or reset or relocated thereon as required.by the City Building Official at the expense of the holder of this permit. 10. The holder shall save and keep the City harmless from any and all damages, claims, or injuries that may occur by reason of the construction, maintenance, and operation of said facility. 11. The holder shall complete the requested work within days or this permit shall become null and void. In the event the work requested is not completed upon the expiration date of this permit, the City shall have the right to complete such work and to charge the holder of the permit for all costs incurred in completing said work. 12. The holder shall post a cash or surety bond with the City Manager in the sum of$ dollars to guarantee performance of the obligations herein, and to guarantee maintenance of the right-of-way described herein for a period of one (1) year following completion of the requested installation. In the event a surety bond is posted, the surety bond shall be made payable to the City and shall obligate the surety to hold the City harmless in the event the holder of this permit should fail to meet any of its obligations hereunder. The bond shall also indemnify the City for all court costs and reasonable attorneys fees in the event legal action is required to collect on said bond. SUBMITTED BY: (Permittee) Lisa Wood Duke Energy Signature &Title "eed Address 4427 Pet Lane ste 101, Lutz, FL, 33559 coastalpermitting@duke-energy.com APPROVED BY: CITY OF ZEPHYRHILLS Building Official Date: Utilities Supervisor Date: �.•?,� -�?a Public Works ENO op N PU Cler-,Iwo &C +U7511. Date: City Manager Date: Q USP: BREAKER C344 Safety Reminders/Adverse Conditions ■ P1:28.265249,•83.177675 SAFETYFirst a"eF=a CAUTION: nPEusou.«ccouu.eanY >> -VEGETATION NEAR Pl eL GY �ncmecuauc �s4�� -WOODEN FENCE NEAR P2 ►IIMAl10 mcce—N REMEMBER:Work zone area conditions may have changed for this JobI Everyone is responsible for verifying the above safety information is correct prior to any work being performed each day. I 1 y � 1 T N -_-� PI 11427400529040 PAD-1 14 1700529040 ——r --� OPEN ACCESS �'= I R/I-ELBOWS 74n :. :. . :: : :::: ..:. I 38609 _� C ..1. u-'.,,ne IPAD-11424;00529040 I 1 �� POLL-27688(8-30-NoU 1 ), f ............ .. ;..� EN AVE `` r (�No ic CAS �4 n #2 AL UG(C)) I-1/0 AL UG(G) I- "- .DPE I 38610 +A L Ll I SCOPE OF WORK: ill work Order Number 34724126 REPLACE 150 FT OF 1/0 AL UG PRIMARY CABLE FROM t TRANSFORMER 11427500528850 TO TRANSFORMER 11427400529040 I A Contact Phone �bSite nddm:e 38609 CAMDEN AVE NEW CABLETO BE INSTALLED VIA CONDUIT �,> PAD-1 1=L1,E) 3_ 6n �I 1 city ZEPHYRHILLS t County CO FL,PAS CO t. P2 state,zip PROJECT LEAD:ALBERTO CRUZ 11427500528850 I,gyp_ Designer ALBERTO CRUZ PHONE:321-316-4846 EXT.1115 CLOSED ACCESS EMAIL:ALBERTO.CRUZ@DUKE-ENERGY.COM I R/I-ELBOWS p°s,an°rPh°ne 321-316 4846 Pl CONSTRUCTION NOTES: .fu', tJ °-110 C344 -PI IS ACCESSIBLE BY TRUCK FROM 38609 CAMDEN AVE LOCATE Pl AT SOUTH-EAST C/O PROPERTY VIE Pm myV°a9, 12.47/7.2 kV -DISTANCE FROM EOP TO Pl IS APPROX 19 FT TREj,Z IS A Peml R°pM°d V°8_No_ -LIGHT TRAFFIC AREA,MOT IS REQUIRED Pe RTAP PmmIITYPotNo.2 - P2 CONSTRUCTION NOTES: P—A TypdNo -P2 IS ACCESSIBLE BY FOOT FROM 38610 CAMDEN AVE J P.O,ATY".4 LOCATE P2 AT SOUTH-EAST C/O PROPERTY -P2 IS IN BACKLOT,MOT NOT REQUIRED p DUKE Sheet POLfi 27689 -30-Non 462 ENERGY® S� 1° 6o. Legend for Construction Prints 0 Existing Overhead Install Overhead R/W C/L R/W Transformer Transformer 60' ® I Existing Underground ' Install Underground Transformer j Transformer I I I P Install Pedestal Install Recloser I I I I Existing Down Guy ) Install Down Guy FRONT YARD BACKLOT I I I O Existing Pole Install New Pole I Existing Fuse Install Fuse EOP EOP Overhead Cable Closed Switch 17' 26' 17' i I I GENERAL CONSTRUCTION NOTES I I I I • DUKE ENERGY TO RESTORE RIGHT OF WAY TO EQUAL OR BETTER THAN EXISTING CONDITION. I � P3 _ I I P2 • TO AVOID CONFLICTS,CONTRACTOR WILL COORDINATE DEPTH OF UNDERGROUND APPROX.19' FACILITIES WITH THE MUNICIPALITY INSPECTOR P.RIORTO BORES BEING INSTALLED. f TFMR I I TFMR1 I � • MINIMUM DEPTH OF CABLE IN CONDUIT IS 36INCHES BELOW GRADE.THREE FEETOF S'EASEMENT S'SDWK 12'GRASS 12'GRASS S'SDWK S'EASEMENT SEPARATION FROM EXISTING UTILITIES AND STORM WATER/SEWERS REQUIRED. , I • ALL PULL BOX LIDS SHALL BETRAFFIC RATED WHEN INSTALLED WITHIN THE RIGHT OF WAY. I I • CONTRACTOR SHALL MAINTAIN AN UNINTERRUPTED ACCESS TO ALL DRIVEWAYS, I SIDEWALKS AND SIDE STREETS ALWAYS,UNLESS OTHERWISE APPROVED ON THE MOT PERMIT. I I I I • A SEPARATE PERMIT WILL BE REQUIRED FOR ANY SUBSURFACE TEST HOLES UNDER I PAVEMENT. I REPLACE 150'OF 1/0 AL UG PRIMARY CABLE IN 3" • DUKE ENERGYTO MAINTAIN 3 FEETMINIMUM COVER. I TYPICAL CROSS SECTION HDPE CONDUIT VIA DIRECTIONAL BORE FROM TRANSFORMER(Pl)LOCATED IN 5'PLATTED • ALL OTHER RIGHT OF WAY USERS AND MUNICIPALITIES IN THE IMMEDIATE VICINITY OF THE I FOR CAMDEN AVE. EASEMENT CROSSING CAMDEN AVETO PROPOSED CONSTRUCTION/INSTALLATION HAVE BEEN NOTIFIED IN WRITING. I LOOKING EAST TRANSFORMER(P2)LOCATED IN 5'PLATTED i I EASEMENT IN BACK LOT I • MINIMUM DEPTH OF CABLE AND CONDUIT UNDER SWALES AND DITCHES IS 3 FEET BELOW I I THE BOTTOM OF THE SWALES AND DITCHES. I I � • MINIMUM HEIGHT OF OVERHEAD WIRES AND CABLE IS 18 FEET OVER ROADWAYS AND 16 FEET OVER DRIVEWAYS. I ** BEFORE DIGGING,CALL SUNSHINE @ 1(800)432-7770 EXIST UTILITY ABEV BRIATIONS: PROJECT LOCATION: WO#34724126 � DUKE ** CAMDEN AVE �ENERGY. S-SEWER�R-RECLAIMED WATER�W-POTABLEWATER I G-GAS�E-ELECTRIC�EXIST UTILITIES @ ASSUMED 36"MIN DEPTH,LOCATIONS ARE APPROXM DRAWN: ATE C-COMMUNICATIONS,ALARM,SIGNAL,CABLES OR CONDUIT "NOT TO SCALE DATE:N:/Ol/2 0 't r s n F•�r�%�/ 4 �kt, ,rye r .. �.- ��^Y .:� � -1 y�r�� �2 '3%:. `n}✓ �_. v�4 i f �4-"5 71Y. _.._tom T � +. �•ur�C. +ter.."t�� _ s #i si �( i SYMBOLS: ® work Area ■ Channelizing Device(See Index 102-600) [p Work Zone Sign Buffer Space 2501 C B A Flogger Sce b Lane Identification+Direction of Traffic Table 1 Q ROAD PIIEPIAEp DpppE MURK TO STOP µEpp AHEAD c5 ————————————————————— a———————————— -..-r. ——__—_—_—_—————_—————_———_—_——_—_— b Work Area b Tangent Device Spacing(See Table 1) ROM ONE WE SE NARK pap PPE""ia, AHEao treAa Tosrov Taper Length D 50'To 100 May Be omitted if ROAD WORK AHEAD sign is installed upstream within the project limits. rt A B C WITHOUT TEMPORARY RAISED RUMBLE STRIPS GENERAL NOTES: TABLE 1 7.Special following may be required in accordance with these notes 4.When o side road intersects the highway within the TTC zone,place and the following sheets: additional TTC devices in accordance with other applicable TCZ Indexes. DEVICE SPACING 5.The two channelizing devices directly in front of the work area may be Distance A.Railroad Crossings: Maximum Spacing Maximum Spacing o/ a.If an active railroad crossing is located closer to the Work Area than omitted provided vehicles in the work area have high-intensity rotating, posted o/Cones or Type 1 or T Between flashing,oscillating,or strobe lights operating. Type rl Signs Space the queue length plus 300 feet,extend the Buffer Space as shown on Speed Tubular Markers Barrfcades/Panels/Drums 9 Space Sheet 3. 6.When Buffer Space cannot be attained due to geometric constraints,use b.If the queuing of vehicles across an active railroad crossing cannot be the greatest attainable length,not less than 200 It.for posted speeds On a On a On a On a avoided,provide a uniformed traffic control officer or flagger at the greater than 25 mph. Taper Tangent Taper Tangent A B C D highway-rail grade crossing to prevent vehicles from stopping within the highway-rail grade crossing,even if automatic train warning 25 20' 50' 20' 50, 2001 200' 200' IOU 155' 7.ROAD WORK AHEAD and the BE PREPARED TO STOP signs may be omitted if devices are in place. 30 20' 50' 20' 50' 200' 200' 200' 100' 200' B.If the Work Area encroaches on the Centerline,use the Layout for all of the following conditions are met: Temporary Lane Shift to Shoulder on Sheet 3 only if the Existing 35 20' S0' 20' S0' 200' 200' 200' 100' 150' A Work o Paved Shoulder width is sufficient to provide for an 11'lane A. operations are 60 minutes or less. 40 20' 50, 20' 50' 20' 200' 200' 100' 305' between the Work Area and the Edge of Existing Paved Shoulder. B.Speed limit is 45 mph or less. Reduce the posted speed when appropriate. C.There are no sight obstructions to vehicles approaching the work area for 45 20' 50' 20' 50' 350' 350' 350' 175' 360' a distance equal to the Buffer Space shown in Table 1. 50 20' 50 20' 100, 500' 500' S00' g500' 730' 2.Temporary Raised Rumble Strips: D.Vehicles in the work area have high-intensity,rotating,flashing,oscillating, 55 20' S0' 20' !00' 2640' I500 1000' or strobe lights operating. A.Use when both of the following conditions are met concurrently: E.Volume and complexity of the roadway has been considered. GO 20' 50 20' 100 2640' 1500' 7000' a. Existing Posted Speed is 55 mph or greater; F.If a railroad crossing is present,vehicles will not queue across rail tracks. 65 20' 50' 20' 100' 2640' 1500' 1000' b.Work duration is greater than 60 minutes. G.AFADs are not in use. S.Use a consistent Strip color throughout the work zone. 70 20' 5a 20' 100' 2640' 1500' 1000' C.Place each Rumble Strip Set transversely across the lane at locations B.See Index 102-600 for general TCZ requirements and additional information. shown. 9.Automated Flagger Assistance Devices(AFADs)may be used in accordance D.Use Option 1 or Option 2 as shown on Sheet 2.Use only one option with Specifications Section 102.990 and the APL vendor drawings. throughout work zone. 3.Additional one-way control may be provided by the following means; CONDITIONS A.Flag-carrying vehicle; B.Official WHERE ANY VEHICLE,EQUIPMENT, C.Pilot vehicles:vehicle; _ WORKERS OR THEIR ACTIVITIES D.Traffic signals. ENCROACH THE AREA BETWEEN THE CENTERLINE AND A LINE 2' When a in erssight are the sole means of ono-waytco control,the t aggersall times, OUTSIDE THE EDGE OF TRAVEL WAY. must be in sight o/each other or in direct communication at all times. LAST Z DESCRIPTION: FY 20I9-20 INDEX SHEET REVIsrON ° FDOT TWO-]LANE, TWO-WAY, 111011117 W �— STANDARD PLANS WORK WITHXN THE TRAVEL WAY 102-603 1 Of 3 oc SYMBOLS: ® Work Area Channelizing Device(See Index 102-600) C B [p Work Zone Sign A jr' Flagger ec "250' Lane ltlentificatron+Direction of TrafficTemporary Raised Rumble Strip Se[(See GENERAL NOTE 2J1 —————————————— a a Work Area 250' 250' 250' D Temporary Raised Rumble Strip Set (See GENERAL NOTE 2) ROAD RONRO: SrRT ONE IANE OE WORK SrXwS INVOpR RM PREPMa. AMEAO MW UNE PHEN io SrOP * A B C See Sheet I For Layout *May Be omitted if ROAD WORK AHEAD sign is installed upstream within the project limits. WITH TEMPORARY RAISED RUMBLE STRIPS (When Required See GENERAL NOTE 2) e C \e poi`met l _`Pa eSSAs PPr S�r p�Safe °�iaP 's`t �a sn nn S�eA v �SYP tel E(9a�e /TyaJ / �odPo\Yn5tt1P oy rp 0 lane of ypJ / Edge bine brne Yt�.`1el Ep9a e a Edge l n / Cei\1ne / oil ne / CYeeo-0 l REMOVABLE POLYMER STRIPING TAPE MOLDED ENGINEERED POLYMER SET RUMBLE STRIP SET RUMBLE STRIP SET OPTION - 1 OPTION - 2 TEMPORARY RAISED RUMBLE STRIPS LAST Zo DESCRIPTION: FY 2019-20 INDEX SHEET REVISION h FDOT TWO-LANE, TWO-WAY, 21101117 W -- STANDARD PLANS WORK W71THIIN THE TRAVEL WAY 102-603 2Of 3 C Taper Length Extended Buffer Space 250' C Cont.Layout 50'To 10D co xor Cont.Layout srov ON � TRACKS x r �-..-.— .-.- .-r.-r.-r.—,-r,-r ————————--————————— •,Nfork Area' 1Y Clear(Typ.,Each Side) •////////// R/R Tracks 50'Tangent Taper r Length h Device Spacing(5ee Table 1) TEMPORARY RAILROAD CROSSING BUFFER SPACE EXTENSION Shifted Lane(I P Min.) C Taper Length Buffer Space(See Table 1) Buffer Space(See Table 1) 375' C Coynt. 50'To 100' Layout Edge Of Existing Paved Shoulder(Typ.) Layout — I r I — -- — •------•—•—• •-- ---- — ------------------------- Edge Of Existing Travel Lane(Typ.) Taper Length Device Spacing(See Table 1) Tangent 50'To 100' TEMPORARY LANE SHIFT TO SHOULDER WHEN WORK AREA ENCROACHES ON THE CENTERLINE SPECIAL CONDITIONS Cross Reference: 1.See General Note 1,Sheet 1 for more Information. SPECIAL CONDITIONS LAST 2 DESCRIPTION: FY 20I9-20 INDEX SHEET REVISION ° FOOT TWO-LANE, TWO-WAY, 11101117 'c sr- STANDARD PLANS t ORK WII'd HIIN TH[E 'd RAVE1L WAY 102-603 3 of 3 SYMBOLS GENERAL NOTES: ® Work Area 1.When encroaching work requires a sidewalk closure for 60 6.Provide a cross-slope with a maximum value of 0.02 for all temporary walkways. minutes or greater,provide an alternate pedestrian route. ■ Channehzing Device 7.Maintain temporary walkway surfaces and ramps that are stable,firm,slip-resistant, [p 2.For spacing of vehicular Channelizing Devices,see applicable and free of any obstructions or hazards such as holes,debris,mud,construction Work Zone Sign vehicular temporary traffic control Indexes. equipment.and stored material. CR Required Locations For Either Temporary Or Permanent Curb Ramps. 3.Cover or deactivate pedestrian traffic signal display(s)controlling B.Remove temporary walkways inomedtately after reopening of the sidewalk,unless closed crosswalks. otherwise noted in the plans. b Lane identification+Direction of Traffic Pedestrian Longitudinal Channelizing Device(LCD)with 4.For post mounted signs located near or adjacent to a sidewalk, 9.Meet the requirements of Index 522-002 for temporary curb ramps. a Mounted Work Zone Sign or separate Work Zone Sign maintain a minimum 7'clearance from the bottom of the sign panel to the surface of the sidewalk. 10.Place pedestrian longitudinal channolizing device(s)across the full width of the F■ Pedestrian Longitudinal Channelizing Device(LCD) closed sidewalk.For temporary walkways,similar to the Sidewalk Diversion, ® Temporary Srtlewalk 5.Provide a 5'wide temporary walkway,except where space restrictions place LCDs to delineate both sides of the temporary walkway. warrant a minimum width of 4'.Provide a S x 5'passing space for temporary walkways less than 5'in width at intervals not to 71.For sidewalk diversions,ensure that there is sufficient RNf for placement of exceed 200'. temporary sidewalk and pedestrian longitudinal channelizing devices. a CR b K�1 b 4 f:R d 4 3a3Hssoao DETOUR I p< yjFry 03SO10 NNM301S 8 KI anoTia O1 p I O3SOlO w DETOUR ry a ■ � AtlMNMM �S �lVM3aIS ~ NYaLs3D3a c I RE 1,1 a` — �U rn 1010 SIDEWALK CLOSED PEDESTRIAN J� G� WALKWAY/ ~ ■ DETOUR Q ano�a SIDEWALK CLOSED ano�a LP C�r � anot3a L J tr ROAD tr II ROAD riOj l t3 i�>� .gC Q j WORK WORK IO AHEAD AHEAD x�EARno ;u CROSSWALK CLOSURE AND SIDEWALK DETOUR SIDEWALK DIVERSION PEDESTRIAN DETOUR LAST :Z'O DESCRIPTION: REVISION FDOTT FY 2019-20 PEDESTRHAN CONTROL FOR CLOSURE OFSHDEWALKS INDEX SHEET 11101117 �- STANDARD PLANS 102-660 1 of 1 a