HomeMy WebLinkAbout20-1008 iron City of Zephyrhills PERMIT NUMBER :`: ' ;• 5335 Eighth Street Zephyrhills, FL 33542 BNR-001008-2020 Phone: (813)780-0020 Fax: (813)780-0021 Issue Date: 11/24/2020 Permit Type: Building New (Residential) Prop_erty�Number Street Address 04 26 210120 00000 0370 6374 Bradford Woods Drive Owner Information Pe mit Infor.,mation Contractor Information f- Name: PULTE HOME COMPANY LLC Permit Type:Building New(Residential) Contract r- PULTE HOME COMPANY Class of Work:SFR Construct LLC Address: 2662 Falkenburg S Rd Building Valuation:$119,749.00 RIVERVIEW,FL 33578 Electrical Valuation:$5,493.00 W Phone: (813)964-5182 Mechanical Valuation:$5,145.00 ogy Plumbing Valuation:$5,147.00 Total Valuation:$135,534.00 Total Fees:$14,055.68 Amount Paid:$14,055.68 Date Paid:11/24/2020 8:48:14AM Project Description CONSTRUCT SINGLE FAMILY 2,485 SID FT Application FeesWWWpM Electrical Permit Fee $67.46 Water Connection Residential Fee $1,010.00 Electrical Plan Review Fee $33.73 Plumbing Plan Review Fee $32.87 Mechanical Plan Review Fee $32.86 Driveway Fee $45.00 Address Fee $30.00 School Impact Fee $8,328.00 Public Safety Impact Fee-Police $254.00 Building Plan Review Fee $314.37 Irrigation 3/4 Meter(Calc) $473.78 SIF 1 percent Fee $83.28 Plumbing Permit Fee $65.74 Building Permit Fee $628.74 3/4 Water Meter Fee(Calc) $473.78 Sewer Connection Residential Fee $2,090.00 Public Safety Impact Fee-Admin $26.35 Mechanical Permit Fee $65.72 REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each subsequent reinspection. Notice: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permit required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner:Your failure to record a notice of commencement may result in your paying twice for improvements to your property.If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications add fee Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. AIL NTRACTOR SIGNATURE PE IT OFFICE PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER INSTR#2020182845 OR BK 10205 PG 3977 Page 1 of 1 10/29/2020 10:55 AM Rcpt:2220882 Rec:10.00 DS:0.00 IT:0.00 Nikki AlvarezSowles,Esq.,Pasco County Clerk&Comptroller Penh No. PecellDNo 04-26-21-0120-00000-0370 NOTICE OF COMMENCEMENT stateof Florida County of Pasco THE UNDERSIGNED hereby gives notice that Improvement will be made to certain real property,and In accordance wish Chapter 713.Florida Statutes, the following Information la provided in this Notice of Commencement 1. Description o(Property:Parcel Identification No. LOT 0370 BLK 00000 Oaks of Pasco Street Address: 6374 Bradford Woods Drive,Zephyrhills,FL,33542 2 General DeseipTwn of improvement New Construction-Single Family to include any construction of home. pool,screen enclosure.deck,irrigation,water,sewer,and ALL other irnproyements. 3. Owner Information or Lessee information tithe Lessee contracted for the Improvement Pulte Home Company,LLC 2662 S.Falk"&.g Road Riverview FL Address City Stsle Interest In Property: Fee Simple Name of Fee Sbmpla Tigaholder, Of different from Owner listed above) Address City State 4. contractor: y Pulte Home Company,LLC 2662 S.. alkenbura Road Riverview FL Address City Slate Contractor's Telephone No.: 813-964-5115 5. Surety. N/A Name Address City Stele Amountof Bond:$ Telephone No.: 6. Lender. N/A New Address City State Lendeh Telephone No.: 7. Persons within the State of Florida designated by the owner upon whom notions or other documents may be served as provided by Section 713.13(1)(a)(7),Florida Statutes: NIA Name Address city State Telephone Number of Designated Person: 6. In addition to himself,the owner designer es NIA of_ to receive a copy or the Llenar s Notice as provided in Section 713.13(1)(b),Florida Statutes. Telephone Number of Person or Entity Designated by Owner. 9. Expiration date of Notice of Commencement(the expiration date may not be before the completion of construction and final payment to the contractor,but wAI be one yearfrom the date of recording unless a dlfferem date Is spewed): WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT RESULT IN YOUR IMPROPER PAYMENTS FORS IMPROVEMENTS TDRYOURPPROP9 Y.SECTION&idif OFORicO ME CEMERt AND TBEBE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION.IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. Under penalty of perjury,I declare that 1 have read the foregoing notice of commencement and that the facts stale ereIna true to the best of my knowladge and belief, STATE OF FLORIDA �. COUNTY OF PASCO Signal u con r ssee,or s or Lessee's Authorized Ofti r/Padner/Manager Division VP ofFinan Signatory's TalelOtrrca The foregoing Instrument was acknowledged before me thle 2Lday of October.!020 by Matthew Hurd ea AttOIIIey III Fact of vtiority,e.g.,officer,trustee.attorney in fact)for Pulte Home Companly.LLC (nameofp behalfof*hombn nanentwesexecutedI Personalty Known KI OR Produced Identification❑ Notary Signature r 'Z�GGt� Type of Idanlification Produced Name(Print) Patricia Berthed 5gi� T ® 65171 4ancr 'ASCU COUNTY FLORIDA l _ Permit No. Date Permitted Builder Name/Owner Name ��. / fe � 3 Control W " County Parcel Noo 2G� 21 l 2Z MbDb 03_A2GubDiv: �S ,l Address/Location Classiflcation/Type of Us Q I,e. TRANSPORTATION IMPACT FEE , Rate: Sq:FtUnit- Exempt• Q Yes Q No How Determined Impact Fee Amount Zone No. TAM SCHOOLIMPACTFEE E Account (050) Single-Family Detached House Amount $ (057) Mobile Home (908) Other Residential 23}- Collection Fee 1 Exempt [�Yes..Q No How Determined PAM AAND'RECREATION FEE• Land Account Land Credit Land Total Recreation Account Recreation Credit Recreation /Total Zone TOTALAMOUNT Exempt Yes -[]No How.Determined ' LIBRAW'FEE' Land Accounf Land Credit Land Total Facility Account Facility Credit Facility Total Exempt ❑Yes 0-No How Determined Total Amount RESOURCE FEE ERU TOTAL AMOUNT Prepared By Arc U Checked By NO CERTIFICATE OF;OCCUPANCY.LWILL BE ISSUED OR FIN&JNSPECTION PER<:OIBUIED[1NTik 1'oE t6t.-L Amd.ANTS LISTED hAvit BEEN.-PJ.HAND., RECEIPTED FOR BY A CENTRAL'PERMiTiiN®'OFFics.oF PA$CO COtlNTY AOufaMedgement below does:not lmply acceptance of conaltrence,but si►ppiy receipt of a.copy of.thle form;placing tt�bu1ldtng permit cwnaFon notice of this assessment erid ttia coitidigons of payment for same. DATE RECEIVED BY RECEIPT NO. DATE BY 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department )ate Received gl . , cot V Phone Contact for Permitting rT-rrl-lam-r /I )wner's Name Rul ke. t10 ni L 1Cv iA )Cori L (� Owner Phone Number I — l4� 7wner's Address 2l1�2 S' Fa ll�nbur� .{/ t�(e�IiiP.� L Owner Phone Number Fee Simple Titleholder Name Owner Phone Number Fee Simple Titleholder Address !A JOB ADDRESS s 4�`ve f7/l/ ("L LOT# SUBDIVISION DW�S Jv PARCEL ID# -A/-D/o'j0 G�DDDD l� 70 (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED ® NEW CONSTR 8 ADD/ALT SIGN Q DEMOLISH INSTALL REPAIR PROPOSED USE Q SFR 0 COMM OTHER TYPE OF CONSTRUCTION BLOCK 0 FRAME L� STEEL DESCRIPTION OF WORK BUILDING SIZE SQ FOOTAGE �67� HEIGHT _6 =BUILDING $ ' VALUATION OF TOTAL CONSTRUCTION =ELECTRICAL Is 6Q, a- AMP SERVICE PROGRESS ENERGY Q W.R.E.C. =PLUMBING $ ]MECHANICAL $ `/�:/� VALUATION OF MECHANICAL INSTALLATION (D =GAS = ROOFING = SPECIALTY = OTHER FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES NO BUILDER COMPANY ulaz#VMC ed"Palk(l L1-L SIGNATURE , REGISTERED Y/ N FEE CURREN/- Y/N_ Address �0�8tS% �r �lxlJ llUe� /?o �3 ` License# FJaa(/Y &t5r ELECTRICIAN COMPANY �J i!� SIGNATURE REGISTERED Y/ NJ FEE CURREN �p Address L I !� Va, � i ` License# G EN6 3 3 7 PLUMBER COMPANY �`' ' 1 b6 SIGNATURE / ,I ,/REGISTERED Y/ N FEE CURREN 3�P1, Y/N Address 313�r°� �rru ,F1_-3 78� License# C Cl RTa7-7 MECHANICAL COMPANY lGY7�S /�� �-'�`�� /•r! SIGNATURE I J REGISTERED Y/ N FEE CURREN Y/N R/3 ner1TM'QV'-' RSZa1,FL 3 t�Lv7 License# Address - / OTHER COMPANY EMI I " CA� ��SIGNATURE p, REGISTERED FEE CURREN Y/N Address 11g31 AfV/n D� � �? i a,3 License# 1 6d613.?4-59 -7 i11111111111li11l1111111111i1111111111111111111l1111111111111111111 RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster;Site Work Permit for subdivisions/large projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction. Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. ****PROPERTY SURVEY required for all NEW construction. • ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ e ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ _■—■ ■ ■ ■ . ■ e ■ ■ ■ ■ ■ • ■ ■ ■ Directions: Fill out application completely. Owner&Contractor sign back of application,notarized If over$2500,a Notice of Commencement is required. (AIC upgrades over$7500) *" Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage) Driveways-Not over Counter if on public roadways..needs ROW D Q' i Single Family Dwelling Plan Review Comments 1- F:F.E;.shall be a minimum of 8" above the road elevation and an engineered site plan. 2. Lots shall be graded to com-ply with R401.3 of the F.B.C. 3. Compaction test required if 24"or more of fill dirt is brought in at any one place. 4: Tie in survey,required before pouring concrete. 5. Driveways require a R.O.W. use permit: All 4 sides of driveway thru the sidewalk shall have expansion material. 6. All setbacks shall be met. 7. All property markers shall be uncovered and marked_ at time:of first inspection. 8: All A.D.A.requirements shall be met: 9, No electric,plumbing,mechanical, or framing shall be covered without an inspection and . approval first. 10.All Garages shall comply with section R302.6 of the F.B.-C. (Fire Separation). 11. Appliances shall not be installed in a location where subject to mechanical damage unless protected by approved barriers. M303.4 of the F.B.0 12-Water heaters shall comply with section P607.3 of the F.B.C: 13. Foundation supports for AX units shall be raised at leas_t 3" above finished grade. M1308.:1 14. Return air in all bedrooms. F.B.C. M1620.4 15. Smoke detectors are to be installed in accordance with R3111 of the F.B.C. 16. All glazing requirements are to be in accordance with R308.4 of the FAC: 17. All means of egress are.to be in accordance with R311 of the F.B.C. 18. "Green gypsum board" shall not be used as a backer in showers or tubs. R702.4.2 F.B.C. 10. Combination-type AFCI breakers are required at all locations requiring an AM type breaker. 20. Carbon monoxide alarms will be- re quired in new construction that uses fossil-burning heating or appliances or an attached garage. They shall be installed in accordance with the F.B.C: 21. All plumbing,mechanical, and electrical shall be separate from unit to unit: This includes all underground plumbing and electric. 22. All 2016 N.E.C. Codes will be enforced. 23. Tamper- Resistant Receptacles in accordance with 406.11 of the 2016 N.E:C 24. In accordance with the Land Development Code, lots shall be sodded before firial at least 10 feet arounS the structure. 25. R403.5.3Hot water pipe insulation Insulation for hot water pipe with a minimum thermal resistance (R-value) of R-3 shall be applied to the following: Piping V. inch (19.1 mm) and larger in nominal diameter. Piping.serving more than one dwelling unit. Piping located outside the conditioned space. Piping from the water heater to.a.distribution manifold:. Piping.located under a floor slab. Buried in piping. Supply and return piping in recirculation systems other than demand recirculation systems. 25.Blower door test shall be provided before C.O: 26.A copy of the enerjy-cacls shall be with permit at all times 27. Copy of final insulation-report shall be provided with Permit before final .28. No fence, pool or screen enclosure :is issued with:this Permit F.F.E.-Finished Floor Elevation F.B.C-Florida Building Code 6 h Edition R.O.W.-Right of Way A.D:A.=.Americans with Disabilities Act N.E.C.-National Electric Code (2016) 813-780-0020 i City of Zephyrhills Permit Application Fax-813-780-0021 Building Department Date Received _ ;—/ � n Phone Contact for Permitting ( _ ) (�l 6 n ,/ ,i Owner's Name K/ �7?/' `` //� /3_ � � �� Owner Phone Number SOwner's Address L�k%1 � % C Owner Phone Number Fee Simple Titleholder Name 1111A Owner Phone Number Fee Simple Titleholder Address / JOB ADDRESS LOT r SUBDIVISION )0 56W PARCEL ID# (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED e NEW CONSTR H ADD/ALT 0 SIGN �] 0 DEMOLISH INSTALL REPAIR PROPOSED USE: SFR Q COMM �� OTHER jj TYPE OF CONSTRUCTION BLOCK 0 FRAME /J� STEEL DESCRIPTION OF WORK /!"/• L/ /`N�v ���� �L/ /i'�7 � i/Y(� BUILDING SIZE 1 o ix& SQ FOOTAGE 4 O�J HEIGHT BUILDING r//q VALUATION OF TOTAL CONSTRUCTION ELECTRICAL $ Q® AMP SERVICE PROGRESS ENERGY Q W.R.E.C. 6 =PLUMBING $ 6— 7r�� =MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION =GAS ROOFING Q SPECIALTY 0 OTHER FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES NO/r BUILDER i COMPANY 6 SIGNATURE REGISTERED Y/N FEE CURREN Y/N Address License# 'ELECTRICIAN COMPANY SIGNATURE REGISTERED Y/N; FEE CURREN Y/N Address License# PLUMBER COMPANY SIGNATURE REGISTERED Y/N FEE CURREN Address License# MECHANICAL COMPANY SIGNATURE REGISTERED Y/N FEE CURREN Y/N Address n License# OTHER COMPANY SIGNATURE REGISTERED Y/N FEE CURREN Y/N Address License# iiiiiiiiiil.iiiiiilt ilitiliiiiii iiiti €ilflEttfEl[t.l<tt#� 1�161t1[1f� 1 .1f1� lf �il«7 RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date.Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster;Site Work Permit for subdivisions/large projects COMMERCIAL Attach(2).complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction. Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance----. SIGN PERMIT Attach(2)sets of Engineered Plans. ****PROPERTY SURVEY required for all NEW construction. Directions:. Fill out application completely. Owner&.Contractor sign back of application,notarized If.over$2500;a Notice of Commencement is required.(A/C upgrades over$7500) ** Agent(for the contractor).or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage) Driveways-Not over Counter if on public roadways..needs ROW 0 1-'aV-VULU Ulty OT Lepnyrniiis Permit Application t-ax-ts13-tt5U-1JUZ1 Building Department NOTICE OF DEED RESTRICTIONS:The undersigned understands that this permit may be subject to"deed"restrictions"which may be more restrictive than County regulations.The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES:If the owner has hired a contractor or contractors to undertake work,they may be required to be licensed in accordance with state and local regulations.If the contractor.is not licensed as required by law,both the owner and contractor may be cited for a misdemeanor violation under state law.If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work,they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847-8009. Furthermore,if the owner has hired a contractor or contractors, he is advised to have the contractor(s)sign portions of the"contractor Block"of this application for which they will be responsible.If you,as the owner sign as the contractor,that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings,change of use in existing buildings,or expansion of existing buildings,as specified in Pasco County Ordinance number 89-07.and 90-07,as amended.The undersigned also understands,that such fees,as may be due,will be identified at the time of permitting.It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a"certificate of occupancy"or final power release.If_the project does not involve a certificate of occupancy or final power release,the fees must be paid prior to permit issuance.Furthermore,if Pasco County Water/Sewer Impact fees are due,they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713,Florida Statutes,as amended): If valuation of work is$2,500.00 or more, I certify that I,the applicant, have been provided with a copy of the"Florida Construction Lien Law—Homeowner's Protection Guide"prepared by the Florida Department of Agriculture and Consumer Affairs.If the applicant is someone other than the"owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner"prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction,zoning and land development.Application is hereby made to obtain a permit to do work and installation as indicated.I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction,County and City codes,zoning regulations,and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work,and that it is my responsibility to identify what actions I must take to be in compliance.Such agencies include but are not limited to: - Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands, Water/Wastewater Treatment. - Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. - Army Corps of Engineers-Seawalls, Docks, Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. - US Environmental Protection Agency-Asbestos abatement. - Federal Aviation Authority-Runways. I understand that the following restrictions apply to the use of fill: - Use of fill is not allowed in Flood Zone W" unless expressly permitted. - If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume" will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. - If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction, I certify that fill will be used only to fill the area within the stem wall. - If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill, an engineered drainage plan is required. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work,plumbing,signs,wells,pools,air conditioning,gas,or other installations not specifically included in the application.A permit issued shall be construed to be a license to proceed with the work and not as authority to violate,cancel,alter,or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans,construction or violations of any codes.Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance,or if work authorized by the permit is suspended or abandoned for a period of six(6)months after the time the work is commenced.An extension may be requested,in writing,from the Building Official for a period not to exceed ninety(90)days and will demonstrate justifiable cause for the extension. If work ceases for ninety(90)consecutive days,the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF.COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LEND TORNEY BEFQRE RECQRDING YQUR NOTICE chif-cM ENT. FLORIDA JURAT(F.S. 117.03) OWNER OR AGENT CONTRACTOR Subscribed�a„„nd swo to(or aff ed a ore Me this,/ Subscribed and sworn or a irme efore a this / Zt7Z?-V by 11 �%7l.LllL/�20(I�[_1�L� ���i ZD2Gby �ti Who is/ re personally known to me or has/have produced Who is/are personally. nown to me or-has/have produced as identification. as identification. Notary Public Notary Public Comm's o No. 7 Comm' No. ���° �/ Narde of Notary typed, printed or stamped Namef of Notary typed,-printed or stamped PATRICIA BU101'r' MY COMMISSION#GG365171 r P PATRICIA BURCHETf r?`'1 My COMMISSION#GG365171 AEXPIRES:AUG tat 2023 EXPIRES:AUG 13,2023 Bonded through 1st State Insurance Bonded through 1st State Insurance • , CITY OF 1EPHYRHILLS `City Of PuYe:yYater 5335 Eighth Street-Zephyrhills;Florida 33542-4312. (813)780-0000 •Fax (813) 780-0005 GENE;WHITFIELD Mayor June 13 2018 Mr. David Waronker , CITY COUNCIL 1420 Celebration Blvd., Suite 200 LANCE A.SMITH. . Celebration,FL 34747 Council President '.Dear Mr. Waronker, KENNETH M.BURGESS,JR. Vice President City of Zephyrhills Ordinance 1003-08, Section 12, Paragraph' S; provides that planned unit developments (PUD) 'approved prior to September 30; 1988 are CHARLES E.PROCTOR exempt: ,from paying transportation impact fees unless amended to permit additional development that would generate traffic: W.ALAN KNIGHT The Silver Oaks PUD was approved on.its third and final reading on January 11, . JODI WILKESON 1988, and therefore is exempt from paying:transportation impact fees as stipulated. .in Ordinance 1,00308 provided the original permitted number of dwelling-units _ remains the.same: According to.Todd Vande Berg, city planner,those numbers within the Silver Oaks PUD have remained constant. STEVEN F.SPINA City Manager r _ :Therefore, the Oaks at Pasco is exempt from paying these,fees. A copy of Ordinance 1003-08 is provided for your information. The exemption and credits LORI L.HILLMAN City clerk,CMC section is located on page 10. MATTHEW E.MAGGARD. Sincerely, City.Attorney. -Steven F, Spina,PhD City Manager . cc: Todd Vande Berg, City Planner - Bill Burgess,Building Official Matthew E. Maggard, City Attorney 91 Qx -..t gti s0 Ic S ! I 35 ! I f36 i-- 7, i t 39 I + 39 I f 40 1 C CAM `c�2.35I S F-92,1,i� I FF=g1.8� !lo 91-61 t l g1.36i .j .121 t I t 1 7�- n._ - _ - 77 74 5 7a >q fin r r PLOT PLAN DESCRIPTION:(AS FURNISHED) LOT 37, OAKS OF PASCO AS RECORDED IN PLAT BOOK 80, PAGE(S) 113-118, OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. ON LOT CALCULATIONS LOT = 5,750 SO. FT. LIVING AREA = 1,850 SQ. FT. GARAGE = 524 SO. FT. ENTRY = 21 SO. FT. LANAI = 90 SQ. FT. PATIO = 0 SO. FT. DRIVEWAY = 328 SO. FT. A/C PAD = 9 SQ. FT. WALKWAY = 41 SQ. FT. IMPERVIOUS = 50% 2863 SQ. FT. 2,887 SQ. FT.SOD a. OFF LOT CALCULATIONS RIGHT OF WAY = 400 SQ. FT. DRIVE APRON = 57 SQ. FT. PUBLIC S/W = 250 SQ. FT. ill = 30' SOD = 93 SO. FT. GRAPHIC SCALE TOTALS - AREA = 6.*150 SQ. FT. 0 15 30 DRIVEWAY = 385 SO. FT. SIDEWALK = 291 SQ. FT. SOD = 2,980 SQ. FT. 00 rn S82*53'12'E 0 L-;I.. 20.00, _j Cc o 2-53 S8 '12"E 115. 031 C) 64.o* 0 E, 64.00, .30.51 0 0 COVERED , 00 ENTRY 0 "I'll,1 20.5, 9.31 PROPOSED b L0 C) w(, L.1 cv EL ZI'l HIGHGATE cs 0 ELj FM1 - n -�: E- If 4 GARAGE EXT cs 6:R: 5.31 FINISHED FLOOW 05.uj a b p b J ELEVATION=91.61, 0 a 00 g 0 b 51.0, b 0 N82-53'12spw 115.0o'v) V) 0 PREPARED FOR: lip BUILDING SETBACKS FRONT: 20' REAR: 10, SIDE: 5- SIDE STREET- 15' LEGEND: NOTES: BUILDING SETBACK LINE pt POINT OF INTERSECTION PC POINT OF CURVATURE 1. PROPOSED ELEVATIONS SHOWN HEREON ARE BASED CENTERLINE PT PONT OF TANGENCY ON THE APPROVED ENGINEERING PLANS PREPARED RIGHT OF WAY LINE RP RADIUS POINT BY CORNELISON ENGINEERING & DESIGN INC. XX.XX PCP POINT OF REVERSE CURVATURE PROPOSED ELEVATION PCP PERMANENT CONTROL POINT 2. ELEVATIONS ARE BASED ON NAVD 1988 TYP TYPICAL DATUM. PROPOSED DRAINAGE FLOW cs CONCRETE SLAB THIS PLOT PLAN IS INTENDED FOR PERMITTING PURPOSES CONCRETE (C(p) PER PLAT) CALCULATED ONLY. THIS IS NOT INTENDED FOR THE CONSTRUCTION OF FB PLAT BOOK THE PROPOSED STRUCTURE. THE CONTRACTOR AND/OR A/C AIR CONDITIONER FIGS PAGES OWNER ARE REQUIRED TO VERIFY ALL SETBACKS, BUILDING S/W SIDEWALK SO. FT. SQUARE FEET DIMENSIONS, AND LAYOUT SHOWN HEREON PRIOR TO ANY F1R.M.F.E.M.A. FEDERAL EMERGENCY MANAGEMENT AGENCY FLOOD INSURANCE RATE MAP CONSTRUCTION. NAVD NORTH AMERICAN VERTICAL DATUM SSE SANITARY SEWER EASEMENT THIS IS NOT A SURVEY. DE DRAINAGE EASEMENT THIS IS A PLOT PLAN ONLY UE UTILITY EASEMENT FLOOD NOTE: I HAVE EXAMINED THE F.I.R.M. MAP NO. 12101CO289F SURVEYOR NOTES: DATED 09/26/2014 AND FOUND THE SUBJECT PROPERTY APPEARS TO LIE 1. THE SURVEYOR.HAS NOT ABSTRACTED THE PARTIALLY IN ZONE"X' &"AE. ZONE'X, AREAS DETERMINED TO BE LAND SHOWN HEREON FOR EASEMENTS, RIGHT OUTSIDE THE 0,2%ANNUAL CHANCE FLOODPLAIN. ZONE'AE".AREAS OF WAY, RESTRICTIONS OF RECORD WHICH' DETERMINED.TO BE SPECIAL FLOOD HAZARD AREAS SUBJECT TO MAY AFFECT THE TITLE OR USE OF THE LAND. INUNDATION BY THE 1%ANNUAL CHANCE FLOOD EVENT, BASE FLOOD ELEVATIONS DETERMINED TO BE 88.5'. THE SURVEYOR MAKES NO GUARANTEES AS TO THE ABOVE INFORMATION. PLEASE CONTACT THE 2. NO UNDERGROUND IMPROVEMENTS HAVE BEEN LOCAL F.E.M.A.AGENT FOR VERIFtGATiON. LOCATED EXCEPT AS,SHOWN. BEARING BASIS:BEARINGS SHOWN HEREON ARE.BASED ON THE CENTERLINE OF 3. NOT VALID WITHOUT.THE AUTHENTIC A5M ELECTRONIC SIGNATURE AND THE AUTHENTIC BRADFORD WOODS DRIVE BEING N07*06'48'F- PER PLAT. ELECTRONIC SEAL OF A FLORIDA LICENSED REVISED: ^M I—= F?,' I (Z,— SURVEYOR AND MAPPER. (FIELD DATE:) 4:3 u F111\/[=-"*Yl 11 " SCALE: I tl DIgItallysignedbyJamesINBoleman 30 FEET ''MAPPING, SuRVEYING& APPROVED BY; JB 8c MAPPING INC. MAPPING.INC,­Jm.1 W B.1—am CERTIFICAT10N OF AUTHORIZATION NUMBER LB#6393 ­11=14.1-.. ""'P—t-c"FOR Di,,� 11:11:06-DWINI' 3191 MAGUIRE BOULEVARD, SUITE 200 THEAdbeA­I.!-*I-1I.U3 FIRM JOB NO. 191105 LOT 37 ORLANDO, FLORIDA 32803 (407) 426-7979 DRAWN BY: RMB WWW.AMERICANSURVE'MNGANDMAPPING.COM JAMES W. BOLEMAN PSM# 6485 DATE 10/21 )22011 j PLOT PLAN INVOICE1111 FOR OF r , BILLING CONTACT JODY SALTER PULTE HOME COMPANY LLC 2662 FALKENBURG S RD RIVERVIEW, FL 33578 INVOICE NUMBER INVOICE DATE INVOICE DUE DATE INVOICE STATUS INVOICE DESCRIPTION INV-00001938 11/20/2020 11/20/2020 Due NONE REFERENCE NUMBER FEE NAME TOTAL BNR-001008-2020 3/4 Water Meter Fee(Calc) $473.78 Address Fee $30.00 Building Permit Fee (Q r $628.74 Building Plan Review Fee "L $314.37 Driveway Fee $45.00 Electrical Permit Fee I ` t $67.46 Electrical Plan Review Fee l $33.73 Irrigation 3/4 Meter(Calc) $473.78 3 Mechanical Permit Fee r� $65.72 Mechanical Plan Review Fee V $32.86 Plumbing Permit Fee `(_ I $65.74 Plumbing Plan Review Fee �C $32.87 Public Safety Impact Fee-Admin $26.35 Public Safety Impact Fee-Police $254.00 School Impact Fee $8,328.00 Sewer Connection Residential Fee $2,090.00 SIF 1 percent Fee $83.28 Water Connection Residential Fee $1,010.00 6374 Bradford Woods Drive Zephyrhills, FLORIDA 33542 SUB TOTAL $14,055.68 REMITTANCE INFORMATION TOTAL $14,055.68 City of Zephyrhills 5335 8th Street Zephyrhills, FL 33542 November 20,2020 5335 8th Street,Zephyrhills,FL 33542 Page 1 of 1