HomeMy WebLinkAbout20-1021 Q
City of Zephyrhills PERMIT NUMBER
. - 5335 Eighth Street
Zephyrhills, FL 33542 BGR-001021-2020
Phone: (813)780-0020
Fax: (813)780-0021 Issue Date: 11/10/2020
Permit Type: Building General (Residential)
PropertyNwmber Street Address
10 26 21 0010 12800 0060 37940 6Th Avenue
Owner Information Permitlnformation Contractor Information
Name: JOHN PIDGEON Permit Type:Building General(Residential) Contractor: GAVIN ROOFING
Class of Work:Reroof
Address: Po Box 2104 Total Valuation:$2,400.00
ZEPHYRHILLS,FL 33539-2104 Total Fees:$52.00 /,{�
Phone: Amount Paid:$52.0
Date Paid:11/10/2020 1:36:41PM �
� l
Project Description
METAL REROOF
Application Fees
Building Permit Fee $52.00
REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c)the
local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or
first reinspection,whichever is greater,for each subsequent reinspection.
Notice: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that
may be found in the public records of this county, and there may be additional permit required from other governmental
entities such as water management, state agencies or federal agencies.
"Warning to owner: Your failure to record a notice of commencement may result in your paying twice for
improvements to your property. If you intend to obtain financing,consult with your lender or an attorney
before recording your notice of commencement."
Complete Plans,Specifications add fee Must Accompany Application.All work shall be performed in
accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O.
NO OCCUPANCY BEFORE C.O.
CONTRACTOR SIGNATURE PE IT OFFICE
PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION
CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED
PROTECT CARD FROM WEATHER
813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021
Building Department
Date Received Z 2� Phone Contact for Permitting -
Owner's Name 9T iv' Owner Phone Number
Owner's Address : LID (0�- ✓6- Owner Phone Number
Fee Simple Titleholder Name Owner Phone Number
Fee Simple Titleholder Address
JOB ADDRESS 3 p! /�/� (J ?� //�'• LOT#
SUBDIVISION F PARCEL ID# O`,2 -,`L`� Olig- 8 D® - 019 00
(OBTAINED FROM PROPERTY TAX NOTICE)
WORK PROPOSED NEW CONSTR ADD/ALT = SIGN = = DEMOLISH
R INSTALL H REPAIR
PROPOSED USE = SFR = COMM = OTHER
TYPE OF CONSTRUCTION = BLOCK = FRAME = STEEL Q
DESCRIPTION OF WORK - 0.1-- w17 I ,5,-,f
BUILDING SIZE SQ FOOTAGE= HEIGHT
ILDING $ OD ✓� VALUATION OF TOTAL CONSTRUCTION
=ELECTRICAL $ AMP SERVICE = PROGRESS ENERGY = W.R.E.C.
=PLUMBING $ t�
=MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION
=GAS ROOFING 0 SPECIALTY = OTHER Wi✓
FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES NO C lllllll
BUILDER COMPANY
SIGNATURE REGISTERED Y/ N FEE CURREN
Address License#
ELECTRICIAN COMPANY
SIGNATURE REGISTERED Y/ N FEE CURREN
Address License#
PLUMBER COMPANY
SIGNATURE REGISTERED Y/ N FEE CURREN
Address I License#
MECHANICAL COMPANY
SIGNATURE REGISTERED Y/ N FEE CURREN
Address / -License#
OTHER COMPANY1���✓
SIGNATURE /ram REGISTERED Y/ N_J FEE CURREN Y/N
Address 0 k G el? License# Z��
RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy forms;R-O-W Permit for new construction,
Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed,
Sanitary Facilities&1 dumpster;Site Work Permit for subdivisionsnarge projects
COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction.
Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed,
Sanitary Facilities&'1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance
SIGN PERMIT Attach(2)sets of Engineered Plans.
****PROPERTY SURVEY required for all NEW construction.
Directions:
Fill out application completely.
Owner&Contractor sign..back of application,notarized
If over$2500,a Notice of Commencement is required. (A/C upgrades over$7500)
Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same
OVER THE COUNTER PERMITTING (copy of contract required)
Reroofs if shingles Sdwers Service Upgrades A/C Fences(Plot/Survey/Footage)
Driveways-Not over Counter if on public roadways..needs ROW
NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed"restrictions" -
which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any
applicable deed restrictions.
UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or
contractors to undertake work, they may be required to be licensed in accordance with-state and local•regulations. If the
contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation
under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the
intended work, they are advised to contact the Pasco County Building.Inspection Division—Licensing Section at 727-847-
8009. Furthermore, if the owner has hired k contractor or contractors, he is advised to have the contractor(s) sign
portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the
contractor, that may be an indication that he is'"not properly licensed and is not entitled to permitting privileges in'Pasco
County. :
TRANSPORTATION IMPACT/UTILITIES.IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands
that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of
use in existing.buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and
90-07, as amended. The undersigned also understands, that:such fees,.as may be due, will be identified at-the time of
permitting. It is further understood that Transportation.Impact Fees and Resource Recovery Fees must be paid-prior to
receiving a "certificate of occupancy" or final power release. If the project.does not involve a certificate of:occupancy or
final power release, the fees must be paid priori to permit issuance. Furthermore,Jf Pasco County Water/Sewer Impact
fees are due, they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances.
CONSTRUCTION LIEN LAW(Chapter 713, Florida Statutes, as amended): If valuation of work is$2,500.00 or more, I
certify that I, the applicant, have been provided with a copy of the "Florida,Construction Lien Law—Homeowner's
Protection Guide" prepared by the Florida Depa''tment of Agriculture.and Consumer Affairs. If the applicant.is someone
other than the"owner", I certify that I have obtained a copy of the above described document and promise in good faith to
deliver it to the"owner"-prior to commencement.
CONTRACTOR'S/OWNER'S-AFFIDAVIT: I'certify that all the information in this application is accurate.and that all work
will be done-in compliance with all applicable laws regulating construction, zoning and land development. Application is
hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has :!
commenced prior to issuance of a permit and that all work will'be performed to meet standards of all laws regulating
construction, County and City codes, zoning regulations, and land Aevelopment regulations in the jurisdiction. I also
certify-that I understand that the regulations of other.government agencies may apply to the intended work, and that it is
my responsibility to identify what actions I must take.to be in compliance. Such agencies include but are not limited to:
Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive
...Lands,Water/Wastewater Treatment;
Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering
Watercourses.
Army Corps of Engineers-Seawalls,'Docks, Navigable Waterways.
Department of Health & Rehabilitative Services/Environmental Health Unit=Wells, Wastewater Treatment,
Septic Tanks. . `"'
US Environmental Protection Agency-Asbestos abatement.
Federal Aviation Authority-Runways.,
I understand that the following restrictions apply to the use of fill:
- Use of fill is not allowed in.Flood Zone W"unless--expressly permitted.
If the fill material is to be used.in Flood Zone "A", it is understood that a drainage plan addressing a
"compensating volume" wily be.subrn'itted at time of permitting which is prepared by a professional engineer
licensed by the State of Florida.
If the fill material is to be used .in Flood Zone "A" in connection with a permitted building using stem:wall.
construction, I certify that fill.will-be used only to fill the area within the stem Wall.
If fill material is to be used in. any,iarea, 1-certify that use of such till will not adversely affect adjacent
properties. If use of fill is found to.,adversely,affect adjacent properties, the owner may be-cited for violating
the conditions of the building permit-:1issued:under:.the-attached permit application, for lots less than one (1)
acre which are elevated�by fill, an engineered:drainage'plan"is required.
If I am.the AGENT FOR THE OWNER, I promise;in-good faith:to inform the owner of the permitting conditions set forth in
this affidavit prior to commencing construction. [understand that a separate permit may be required .for electrical work,
plumbing; signs, wells, pools, air conditioning,.gas, or other,installations not specifically included.in the application. A
permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or
set aside any provisions of the technical codes, nor shall issuance of.a permit prevent the-Building Official from thereafter
requiring a correction of errors in plans, construction or violations of.any codes. Every permit issued shall become invalid
unless the work authorized by such permit is commenced within six months of permit issuance, or'if work authorized by
the permit is suspended or abandoned for a period of six(6)months after the time the work is commenced. An extension
may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate
justifiable cause for the extension. If work ceasesifor-ninety(90)consecutive days,the job is considered abandoned.
WARNING.TO OWNER: YOUR FAILURE_TO,RECORD.A NOTICE OF COMMENCEMENT:MAY RESULT.-IN YOUR
PAYING TWICE.FOR-IMPROVEMENTS TO YOUR PROPERTY. IF YOU.INTEND TO OBTAIN'FINANCING,:CONSULT
WITKYOUR LENDEKOR AN ATTORNEY BEFORE RECORDING_YOUR NOTICE.OF COMMENCEMENT.
-- -FLORIDA.JURAT(F.S. 117,0 AJ
- -_ — — -- —
OWNER OR AGENT CONTRACTOR
Subscribed and sworn to(or affirmed)before me this Subscribed and sworn to(or affirmed)before me this
by by
Who is/are personally known to me or has/have produced Who is/are personally known to me or has/have produced
as identification. as identification.
Notary Public) Notary Public
Commission No. Commission No.
Name of Notary typed, anted or stamped
Name of Notary typed;printed or stamped ry tYP printed P
Ar i
FLORIDA rOPAMWaNT OF
Business • ProfessionalRegulation
r
BCIS Home I Log In I User Registration f Hot Topic Submit Surcharge I Stats&Facts Publications E Contact Us I BCIS Site Map Links Search
FI 'da
Product Approval
USER:Public User
8
Product Approval Menu>Product or Application Search>Application List>Application Detail
FL# FL11651-113
Application Type Revision
Code Version 2017
Application Status Approved
Comments ALL WORX.SHAL(,
ArchivedriONA❑ C ' FLORIDACQiWPLY Wiz'
iq Product Manufacturer Gulf Coast Supply&Manufao"O' CITYolt ELgC-rftd� oix�008 � ��j1�(�4
Address/Phone/Email 4020 S.W.449th Street Horseshoe Beach,FL 32648®RDdN�'A''cc�CEFS° C�����HMIs �
(352)498-0778 Ext 0565
jared.pearce@gulfcoastsupply.com
Authorized Signature Jared Pearce
jared.pearce@gulfcoastsupply.com
Technical Representative David Eng i// vv
Address/Phone/Email 14429 SW 2nd PI �V f�c,
Ste G30 nC�T�0� IOA7-&OV
Newberry,FL(352)4 8-0778 669 /�`/I A, y��/� ® 'lo
Info@gulfcoastsupply.com �'11�
Quality Assurance Representative David Eng
Address/Phone/Email 14429 SW 2nd PI
Ste G30
Newberry,FL 32669
(352)498-0778
david.eng@gulfcoastsupply.com
Category Roofing
Subcategory Metal Roofing
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
❑ Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed Daniel S.Kuhn
the Evaluation Report
Florida License PE-75519
Quality Assurance Entity Keystone Certifications,Inc.
Quality Assurance Contract Expiration Date 04/12/2024
Validated By Locke Bowden P.E.
0 Validation Checklist-Hardcopy Received
Certificate of Independence FL11651 R3 COI Cert of Independence 2017-10-09.odf
Referenced Standard and Year(of Standard) Standard Year
FM 4471 1992
TAS 100 1995
TAS 110 2000
TAS 125 2003
UL 1897 2012
UL 580 2006
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 10/10/2017
Date Validated 10/12/2017
Date Pending FBC Approval 10/17/2017
Date Approved 12/12/2017
Summary of Products
Go to Page W 0 0 Pagel/20 0
FL# Model,Number or Name Description
11651.1 0.032"Aluminum 5V Crimp Min 0.032"5 V Crimp Aluminum Roof Panel over 15/32"
Plywood
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL11651 R3 II FL11651 1 R3 Metal Roof Panel Detail-
Approved for use outside HVHZ:Yes sianed.odf
Impact Resistant:N/A Verified By: Dan Kuhn,P.E.75519
Design Pressure:+N/A/-108.5PSF Created by Independent Third Party:Yes
Other:-108.5 psf @ 12"o.c.Install per manufacturers Evaluation Reports
details. Not for use in HVHZ Zones. FL11651 R3 AE FL11651 1 R3 0325vCrimp 15-
32Plvwood NonHVHZ-signed.pdf
Created by Independent Third Party:Yes
11651.2 0.032"Aluminum Gulf Lok Min 0.032"Aluminum Gulf Lok 16"Wide Roof Panel over
15/32"Plywood
Limits of Use Installation Instructions
Approved for use In HVHZ:No FL11651 R3 II FL11651 2 R3 Metal Roof Panel Detail-
Approved for use outside HVHZ:Yes signed.pdf
Impact Resistant:N/A Verified By: Dan Kuhn,P.E.75519
Design Pressure:+N/A/-116.OPSF Created by Independent Third Party:Yes
Other:-52.5 psf @ 5 3/16"o.c.fastener spacing.-116.0 psf Evaluation Reports
@ 5 3/16"o.c.fastener spacing.Install per manufacturers FL11651 R3 AE FL11651 2 R3 032GulfLok 16 15-
details.Not for use in HVHZ Zones. 32Plvwood NonHVHZ-sianed.Ddf
Created by Independent Third Party:Yes
11651.3 1"24ga.Gulf Snap 1"Gulf Snap 24 Ga. 17"wide Roof Panel over 15/32"Plywood
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL11651 R3 II FL11651 3 R3 Metal Roof Panel Detail-
Approved for use outside HVHZ:Yes sioned.odf
Impact Resistant:N/A Verified By: Dan Kuhn,P.E.75519
Design Pressure: +N/A/--131.OPS Created by Independent Third Party:Yes
Other:-67.3 psf @ 24"o.c.clip spacing.-131 psf @ 6"o.c. Evaluation Reports
clip spacing.Install per manufacturers details.For use in FL11651 R3 AE FL11651 3 R3 1 24GuIfSnao 17 15-
HVHZ Zones. 32Plvwood HVHZ-sianed.odf
Created by Independent Third Party:Yes
11651.4 1"24ga.VersaLoc 1"VersaLoc 24ga 16.5"Wide Roof Panel over 15/32"Plywood
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL11651 R3 II FL11651 4 R3 Metal Roof Panel Detail-
Approved for use outside HVHZ:Yes sianed.pdf
Impact Resistant:N/A Verified By: Dan Kuhn,P.E.75519
Design Pressure:+N/A/-138.5PSF Created by Independent Third Party:Yes
Other:-71 psf @ 24"o.c.clip spacing.-138.5 psf @ 6"o.c. Evaluation Reports
clip spacing.Install per manufacturers details.For use in FL11651 R3 AE FL11651 4 R3 24VersaLoc SR 16.5 15-
HVHZ Zones. 32Plvwood HVHZ-sinned.odf
Created by Independent Third Party:Yes
11651.5 1"VersaLoc.032"Aluminum 1"VersaLoc min .032"Aluminum over 15/32"Plywood
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL11651 R3 II FL11651 5 R3 Metal Roof Panel Detail-
Approved for use outside HVHZ:Yes silaned.pdf
Impact Resistant:N/A Verified By: Dan Kuhn,P.E.75519
Design Pressure:+N/A/-101.OPSF Created by Independent Third Party:Yes
Other:-63.3 psf @ 24"o.c.clip spacing.-1O1.0 psf @ 6"o.c. Evaluation Reports
clip spacing.Install per manufacturers details.For use in FL11651 R3 AE FL11651 5 R3 lin 032VersaLoc
HVHZ Zones. SR 16 15-32Plvwood HVHZ-sioned.odf
Created by Independent Third Party:Yes
11651.6 1.5"24ga.Gulf Snap 1.5"Gulf Snap 24ga. 16"Wide Roof Panel over 15/32"
Plywood
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL11651 R3 II FL11651 6 113 Metal Roof Panel Detail-
Approved for use outside HVHZ:Yes signed.pdf
Impact Resistant:N/A Verified By: Dan Kuhn,P.E.75519
Design Pressure:+N/A/-116.OPSF Created by Independent Third Party:Yes
Other:-86.0 psf @ 24"o.c.clip spacing.-108.5 psf @ 12" Evaluation Reports
o.c.clip spacing.-116.0 psf @ 6"o.c.clip spacing.Install per FL11651 R3 AE FL11651 6 R3 1.5 24GulfSnao 16 15-
manufacturers detals.For use in HVHZ Zones. 32Plywood HVHZ-sioned.odf
Created by Independent Third Party:Yes
11651.7 1.5"24ga.VersaLoc 1.5"VersaLoc min 24ga. 16"wide Roof Panel over 15/32"
Plywood
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL11651 R3 II FL11651 7 R3 Metal Roof Panel Detail-
Approved for use outside HVHZ:Yes sianed.odf
Impact Resistant:N/A Verified By: Dan Kuhn,P.E.75519
Design Pressure:+N/A/-123.5PSF Created by Independent Third Party:Yes
Other:-59.75 psf @ 24"o.c.clip spacing.-123.5 psf @ 12" Evaluation Reports
o.c.clip spacing.Install per manufacturers details. For use in FL11651 R3 AE FL11651 7 R3 1.5 24VersaLoc 16 15-
HVHZ Zones. 32Plywood HVHZ-signed.pdf
Created by Independent Third Party:Yes
11651.8 2"24ga.MegaLoc Min 24 Ga.2"MegaLoc 18"wide Roof Panel over 15/32"
Plywood
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL11651 R3 II FL11651 8 R3 Metal Roof Panel Detail-
Approved for use outside HVHZ:Yes signed.pdf
Impact Resistant:N/A Verified By: Dan Kuhn,P.E.75519
Design Pressure:+N/A/-108.5PSF Created by Independent Third Party:Yes
Other:-71.0 psf @ 24"o.c.clip spacing.-108.5 psf @ 12" Evaluation Reports
o.c.clip spacing.Install per manufacturers details.Not for use FL11651 R3 AE FL11651 8 R3 24VersaLoc 18 IS-
in HVHZ Zones. 32Plywood NonHVHZ-sioned.odf
Created by Independent Third Party:Yes
11651.9 24 Ga.Gulf Lok Min 24 Ga.Gulf Lok 16"Wide over 15/32"Plywood
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL11651 R3 II FL11651 9 R3 Metal Roof Panel Detail-
Approved for use outside HVHZ:Yes sianed.odf
Impact Resistant:N/A Verified By: Dan Kuhn,P.E.75519
Design Pressure:+N/A/-96.7PSF Created by Independent Third Party:Yes
Other:-81.75 psf @ 10-1/4"o.c.fastener spacing.-96.76 Evaluation Reports
psf @ 5-1/8"o.c.fastener spacing.-121.75 psf @ 5-1/8" FL11651 R3 AE FL11651 9 R3 24GulfLok 16 15-
fastener spacing.-161 psf @ 5-1/8"fastener spacing.Install 32Plvwood NonHVHZ-sioned.odf
per manufacturers details.Not for use in HVHZ Zones. Created by Independent Third Party:Yes
11651.10 24 Ga.Gulf Seam Min 24 Ga.Gulf Seam 16"Wide Roof Panel over 1x4 Wood
Purlins over 15/32"Plywood
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL11651 R3 II FL11651 10 R3 Metal Roof Panel Detail-
Approved for use outside HVHZ:Yes sioned.odf
Impact Resistant:N/A Verified By: Dan Kuhn,P.E.75519
Design Pressure:+N/A/-93.513SF Created by Independent Third Party:Yes
Other:-93.5 psf @ 18"o.c.Install per manufacturers details. Evaluation Reports
Not for use in HVHZ Zones. FL11651 R3 AE FL11651 10 R3 24GulfSeam 16 1x4 15-
32Plvwood Non HVHZ-sioned.odf
Created by Independent Third Party:Yes
11651.11 24 Ga.Gulf Seam Min 24 Ga.Gulf Seam, 1 3/4"Snap Lock, 18"Wide Roof Panel
over 15/32"Plywood
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL11651 R3 II FL11651 11 R3 Metal Roof Panel Detail-
Approved for use outside HVHZ:Yes sianed.odf
Impact Resistant:N/A Verified By: Dan Kuhn,P.E.75519
Design Pressure:+N/A/-108.5PSF Created by Independent Third Party:Yes
Other:-69.25 psf @ 24"o.c.clip spacing.-108.5 psf @ 12" Evaluation Reports
o.c.clip spacing.Install per manufacturers details.Not for use FL11651 R3 AE FL11651 11 R3 24GulfSeam 18 15-
in HVHZ Zones. 32Plvwood Non HVHZ-sianed.odf
Created by Independent Third Party:Yes
11651.12 26 Ga. 5V Crimp Min 26 Ga.5V Crimp Roof Panel over 15/32"Plywood
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL11651 R3 II FL11651 12 R3 Metal Roof Panel Detail-
Approved for use outside HVHZ:Yes sioned.pdf
Impact Resistant:N/A Verified By: Dan Kuhn,P.E.75519
Design Pressure:+N/A/-156.5PSF Created by Independent Third Party:Yes
Other:-108.5 psf @ 12"o.c.fastener spacing.-156.5 psf @ Evaluation Reports
FL11651 R3 AE FL11651 12 R3 265vCrimo 15-
6"o.c.fastener spacing.Install per manufacturers details.For 32Plvwood HVHZ-sioned.odf
use in HVHZ Zones. Created by Independent Third Party:Yes
11651.13 26 Ga.5V Crimp Min 26 Ga.5V Crimp over 15/32"Plywood
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL11651 R3 II FL11651 13 R3 Metal Roof Panel Detail-
Approved for use outside HVHZ:Yes siioned.pdf
Impact Resistant:N/A Verified By: Dan Kuhn,P.E.75519
Design Pressure:+N/A/-131.PSF Created by Independent Third Party:Yes
Other:-94.25 psf @ 16"o.c.fastener pattern.-131.0 psf @ Evaluation Reports
16"o.c.fastener pattern.Install per manufacturers details. FL11651 R3 AE FL11651 13 R3 265vCrimo 15-
Not for use in HVHZ Zones. 32Plvwood NonHVHZ-signed.pdf
Created by Independent Third Party:Yes
11651.14 26 Ga.5V Crimp Min 26 Ga.5V Crimp Roof Panel over Ix4 Wood Purlins over
15/32"Plywood
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL11651 R3 II FL11651 14 R3 Metal Roof Panel Detail-
Approved for use outside HVHZ:Yes sianed.odf
Impact Resistant:N/A Verified By: Dan Kuhn,P.E.75519
Design Pressure:+N/A/-156.SPSF Created by Independent Third Party:Yes
Other:-108.5 psf @ 12"o.c.fastener spacing.-156.5 psf @ Evaluation Reports
6"o.c.fastener spacing.Install per manufacturers details.For FL11651 R3 AE FL11651 14 R3 265vCrimp 1x4 15-
use in HVHZ Zones. 32Plvwood NonHVHZ-sianed.pdf
Created by Independent Third Party:Yes
11651.15 26 Ga.Gulf Lok Min 26 Ga.Gulf Lok 16"Wide Roof Panel over 15/32"Plywood
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL11651 R3 II FL11651 15 R3 Metal Roof Panel Detail-
Approved for use outside HVHZ:Yes sianed.pdf
Impact Resistant:N/A Verified By: Dan Kuhn,P.E.75519
Design Pressure:+N/A/-161.OPSF Created by Independent Third Party:Yes
Other:-63.5 psf @ 5 3/16"o.c.fastener spacing.-121.75 Evaluation Reports
psf @ 5 3/16"spacing.-161.0 psf @ 5 3/16"o.c.fastener FL11651 R3 AE FL11651 15 R3 26Gulfl-ok 16 15-
spacing.Install per manufacturers details.For use in HVHZ 32Plvwood HVHZ-sioned.odf
Zones. Created by Independent Third Party:Yes
11651.16 26 Ga.Gulf Lok Min 26 Ga.Gulf Lok 16"Wide Roof Panel over 15/32"Plywood
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL11651 R3 II FL11651 16 R3 Metal Roof Panel Detail-
Approved for use outside HVHZ:Yes sioned.odf
Impact Resistant:N/A Verified By: Dan Kuhn,P.E.75519
Design Pressure: +N/A/-63.5PSF Created by Independent Third Party:Yes
Other:-63.5 psf @ 5 3/16"o.c.fastener spacing.-121.75 Evaluation Reports
psf @ 5 3/16"fastener spacing.-161 psf @ 5 3/16"fastener FL11651 R3 AE FL11651 16 R3 26GulfLok 16 15-
spacing.Install per manufacturers details.Not for use in 32Plywood NonHVHZ-signed.pdf
HVHZ Zones. Created by Independent Third Party:Yes
11651.17 26 Ga.GulfPBR Min 26 Ga.Gulf PBR Roof Panel over 15/32"Plywood
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL11651 R3 II FL11651 17 R3 Metal Roof Panel Detail-
Approved for use outside HVHZ:Yes sianed.odf
Impact Resistant:N/A Verified By: Dan Kuhn,P.E.75519
Design Pressure:+N/A/-154.7PSF Created by Independent Third Party:Yes
Other:-59.25 psf @ 24"o.c.fastener pattern.-154.75 psf @ Evaluation Reports
12"o.c.fastener pattern.Install per manufacturer details.Not FL11651 R3 AE FL11651 17 R3 26GulfPBR 15-
for use in HVHZ 32Plvwood NonHVHZ-signed.pdf
Created by Independent Third Party:Yes
11651.18 26 Ga.GulfPBR Min 26 Ga.GulfPBR Roof Panel over 1x4 Wood Purlins over
15/32"Plywood
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL11651 R3 II FL11651 18 R3 Metal Roof Panel Detail-
Approved for use outside HVHZ:Yes sianed.odf
Impact Resistant:N/A Verified By: Dan Kuhn,P.E.75519
Design Pressure: +N/A/-151.7PSF Created by Independent Third Party:Yes
Other:-100.5 psf @ 24"o.c.fastener spacing.-151.75 psf @ Evaluation Reports
12"fastener spacing.Install per manufacturer's details.For FL11651 R3 AE FL11651 18 R3 26GulfPBR 1x4 15-
use in HVHZ Zones 32Plvwood HVHZ-sianed.Ddf
Created by Independent Third Party:Yes
11651.19 26 Ga.GulfPBR Min 26 Ga.GulfPBR over 15/32"Plywood
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL11651 R3 II FL11651 19 R3 Metal Roof Panel Detail-
Approved for use outside HVHZ:Yes signed.pdf
Impact Resistant:N/A Verified By: Dan Kuhn,P.E.75519
Design Pressure: +N/A/-154.7PSF Created by Independent Third Party:Yes
Other:-60.5 psf @ 24"o.c.fastener spacing.-154.75 psf @ Evaluation Reports
FL11651 R3 AE FL11651 19 R3 26Gu)fPBR 15-
12"D.C.fastener spacing.Install per manufacturer's details. 32Plvwood HVHZ-sianed.odf
For use in HVHZ Zones. Created by Independent Third Party:Yes
11651.20 26 Ga.GulfPBR Min 26 Ga.GulfPBR over 1x4 Wood Purlins over 15/32"
Plywood
Limits of Use Installation Instructions
Approved for use In HVHZ:No FL11651 R3 II FL11651 20 R3 Metal Roof Panel Detail-
Approved for use outside HVHZ:Yes sianed.odf
Impact Resistant:N/A Verified By: Dan Kuhn,P.E.75519
Design Pressure:+N/A/-151.7PSF Created by Independent Third Party:Yes
Other:-94.25 psf @ 24"o.c.fastener spacing.-151.75 psf @ Evaluation Reports
12"fastener spacing.Install per manufacturer's details.Not FL11651 R3 AE FL11651 20 R3 26GulfPBR 1x4 15-
for use in HVHZ Zones 32Plvwood NonHVHZ-sioned.odf
Created by Independent Third Party:Yes
Go to Page 0110 Pagel/20 0
Back Next
Contact Us::2601 Blair Stone Road.Tallahassee FL 32399 Phone:850487-1824
The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released In response to a public-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mall.If you have any questions,please contact 850.487.1395.-Pursuant to Section 455.275(1),
Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address If they have one.The emaiis
provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please
provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here.
Product Approval Accepts:
®® ®P Q
A Credit Card _._._..
Safe