Loading...
HomeMy WebLinkAbout20-1021 Q City of Zephyrhills PERMIT NUMBER . - 5335 Eighth Street Zephyrhills, FL 33542 BGR-001021-2020 Phone: (813)780-0020 Fax: (813)780-0021 Issue Date: 11/10/2020 Permit Type: Building General (Residential) PropertyNwmber Street Address 10 26 21 0010 12800 0060 37940 6Th Avenue Owner Information Permitlnformation Contractor Information Name: JOHN PIDGEON Permit Type:Building General(Residential) Contractor: GAVIN ROOFING Class of Work:Reroof Address: Po Box 2104 Total Valuation:$2,400.00 ZEPHYRHILLS,FL 33539-2104 Total Fees:$52.00 /,{� Phone: Amount Paid:$52.0 Date Paid:11/10/2020 1:36:41PM � � l Project Description METAL REROOF Application Fees Building Permit Fee $52.00 REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each subsequent reinspection. Notice: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permit required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications add fee Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. CONTRACTOR SIGNATURE PE IT OFFICE PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department Date Received Z 2� Phone Contact for Permitting - Owner's Name 9T iv' Owner Phone Number Owner's Address : LID (0�- ✓6- Owner Phone Number Fee Simple Titleholder Name Owner Phone Number Fee Simple Titleholder Address JOB ADDRESS 3 p! /�/� (J ?� //�'• LOT# SUBDIVISION F PARCEL ID# O`,2 -,`L`� Olig- 8 D® - 019 00 (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED NEW CONSTR ADD/ALT = SIGN = = DEMOLISH R INSTALL H REPAIR PROPOSED USE = SFR = COMM = OTHER TYPE OF CONSTRUCTION = BLOCK = FRAME = STEEL Q DESCRIPTION OF WORK - 0.1-- w17 I ,5,-,f BUILDING SIZE SQ FOOTAGE= HEIGHT ILDING $ OD ✓� VALUATION OF TOTAL CONSTRUCTION =ELECTRICAL $ AMP SERVICE = PROGRESS ENERGY = W.R.E.C. =PLUMBING $ t� =MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION =GAS ROOFING 0 SPECIALTY = OTHER Wi✓ FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES NO C lllllll BUILDER COMPANY SIGNATURE REGISTERED Y/ N FEE CURREN Address License# ELECTRICIAN COMPANY SIGNATURE REGISTERED Y/ N FEE CURREN Address License# PLUMBER COMPANY SIGNATURE REGISTERED Y/ N FEE CURREN Address I License# MECHANICAL COMPANY SIGNATURE REGISTERED Y/ N FEE CURREN Address / -License# OTHER COMPANY1���✓ SIGNATURE /ram REGISTERED Y/ N_J FEE CURREN Y/N Address 0 k G el? License# Z�� RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster;Site Work Permit for subdivisionsnarge projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction. Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&'1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. ****PROPERTY SURVEY required for all NEW construction. Directions: Fill out application completely. Owner&Contractor sign..back of application,notarized If over$2500,a Notice of Commencement is required. (A/C upgrades over$7500) Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sdwers Service Upgrades A/C Fences(Plot/Survey/Footage) Driveways-Not over Counter if on public roadways..needs ROW NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed"restrictions" - which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they may be required to be licensed in accordance with-state and local•regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building.Inspection Division—Licensing Section at 727-847- 8009. Furthermore, if the owner has hired k contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is'"not properly licensed and is not entitled to permitting privileges in'Pasco County. : TRANSPORTATION IMPACT/UTILITIES.IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing.buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands, that:such fees,.as may be due, will be identified at-the time of permitting. It is further understood that Transportation.Impact Fees and Resource Recovery Fees must be paid-prior to receiving a "certificate of occupancy" or final power release. If the project.does not involve a certificate of:occupancy or final power release, the fees must be paid priori to permit issuance. Furthermore,Jf Pasco County Water/Sewer Impact fees are due, they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713, Florida Statutes, as amended): If valuation of work is$2,500.00 or more, I certify that I, the applicant, have been provided with a copy of the "Florida,Construction Lien Law—Homeowner's Protection Guide" prepared by the Florida Depa''tment of Agriculture.and Consumer Affairs. If the applicant.is someone other than the"owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner"-prior to commencement. CONTRACTOR'S/OWNER'S-AFFIDAVIT: I'certify that all the information in this application is accurate.and that all work will be done-in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has :! commenced prior to issuance of a permit and that all work will'be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land Aevelopment regulations in the jurisdiction. I also certify-that I understand that the regulations of other.government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take.to be in compliance. Such agencies include but are not limited to: Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive ...Lands,Water/Wastewater Treatment; Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. Army Corps of Engineers-Seawalls,'Docks, Navigable Waterways. Department of Health & Rehabilitative Services/Environmental Health Unit=Wells, Wastewater Treatment, Septic Tanks. . `"' US Environmental Protection Agency-Asbestos abatement. Federal Aviation Authority-Runways., I understand that the following restrictions apply to the use of fill: - Use of fill is not allowed in.Flood Zone W"unless--expressly permitted. If the fill material is to be used.in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume" wily be.subrn'itted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. If the fill material is to be used .in Flood Zone "A" in connection with a permitted building using stem:wall. construction, I certify that fill.will-be used only to fill the area within the stem Wall. If fill material is to be used in. any,iarea, 1-certify that use of such till will not adversely affect adjacent properties. If use of fill is found to.,adversely,affect adjacent properties, the owner may be-cited for violating the conditions of the building permit-:1issued:under:.the-attached permit application, for lots less than one (1) acre which are elevated�by fill, an engineered:drainage'plan"is required. If I am.the AGENT FOR THE OWNER, I promise;in-good faith:to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. [understand that a separate permit may be required .for electrical work, plumbing; signs, wells, pools, air conditioning,.gas, or other,installations not specifically included.in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of.a permit prevent the-Building Official from thereafter requiring a correction of errors in plans, construction or violations of.any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or'if work authorized by the permit is suspended or abandoned for a period of six(6)months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceasesifor-ninety(90)consecutive days,the job is considered abandoned. WARNING.TO OWNER: YOUR FAILURE_TO,RECORD.A NOTICE OF COMMENCEMENT:MAY RESULT.-IN YOUR PAYING TWICE.FOR-IMPROVEMENTS TO YOUR PROPERTY. IF YOU.INTEND TO OBTAIN'FINANCING,:CONSULT WITKYOUR LENDEKOR AN ATTORNEY BEFORE RECORDING_YOUR NOTICE.OF COMMENCEMENT. -- -FLORIDA.JURAT(F.S. 117,0 AJ - -_ — — -- — OWNER OR AGENT CONTRACTOR Subscribed and sworn to(or affirmed)before me this Subscribed and sworn to(or affirmed)before me this by by Who is/are personally known to me or has/have produced Who is/are personally known to me or has/have produced as identification. as identification. Notary Public) Notary Public Commission No. Commission No. Name of Notary typed, anted or stamped Name of Notary typed;printed or stamped ry tYP printed P Ar i FLORIDA rOPAMWaNT OF Business • ProfessionalRegulation r BCIS Home I Log In I User Registration f Hot Topic Submit Surcharge I Stats&Facts Publications E Contact Us I BCIS Site Map Links Search FI 'da Product Approval USER:Public User 8 Product Approval Menu>Product or Application Search>Application List>Application Detail FL# FL11651-113 Application Type Revision Code Version 2017 Application Status Approved Comments ALL WORX.SHAL(, ArchivedriONA❑ C ' FLORIDACQiWPLY Wiz' iq Product Manufacturer Gulf Coast Supply&Manufao"O' CITYolt ELgC-rftd� oix�008 � ��j1�(�4 Address/Phone/Email 4020 S.W.449th Street Horseshoe Beach,FL 32648®RDdN�'A''cc�CEFS° C�����HMIs � (352)498-0778 Ext 0565 jared.pearce@gulfcoastsupply.com Authorized Signature Jared Pearce jared.pearce@gulfcoastsupply.com Technical Representative David Eng i// vv Address/Phone/Email 14429 SW 2nd PI �V f�c, Ste G30 nC�T�0� IOA7-&OV Newberry,FL(352)4 8-0778 669 /�`/I A, y��/� ® 'lo Info@gulfcoastsupply.com �'11� Quality Assurance Representative David Eng Address/Phone/Email 14429 SW 2nd PI Ste G30 Newberry,FL 32669 (352)498-0778 david.eng@gulfcoastsupply.com Category Roofing Subcategory Metal Roofing Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer ❑ Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed Daniel S.Kuhn the Evaluation Report Florida License PE-75519 Quality Assurance Entity Keystone Certifications,Inc. Quality Assurance Contract Expiration Date 04/12/2024 Validated By Locke Bowden P.E. 0 Validation Checklist-Hardcopy Received Certificate of Independence FL11651 R3 COI Cert of Independence 2017-10-09.odf Referenced Standard and Year(of Standard) Standard Year FM 4471 1992 TAS 100 1995 TAS 110 2000 TAS 125 2003 UL 1897 2012 UL 580 2006 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 10/10/2017 Date Validated 10/12/2017 Date Pending FBC Approval 10/17/2017 Date Approved 12/12/2017 Summary of Products Go to Page W 0 0 Pagel/20 0 FL# Model,Number or Name Description 11651.1 0.032"Aluminum 5V Crimp Min 0.032"5 V Crimp Aluminum Roof Panel over 15/32" Plywood Limits of Use Installation Instructions Approved for use in HVHZ:No FL11651 R3 II FL11651 1 R3 Metal Roof Panel Detail- Approved for use outside HVHZ:Yes sianed.odf Impact Resistant:N/A Verified By: Dan Kuhn,P.E.75519 Design Pressure:+N/A/-108.5PSF Created by Independent Third Party:Yes Other:-108.5 psf @ 12"o.c.Install per manufacturers Evaluation Reports details. Not for use in HVHZ Zones. FL11651 R3 AE FL11651 1 R3 0325vCrimp 15- 32Plvwood NonHVHZ-signed.pdf Created by Independent Third Party:Yes 11651.2 0.032"Aluminum Gulf Lok Min 0.032"Aluminum Gulf Lok 16"Wide Roof Panel over 15/32"Plywood Limits of Use Installation Instructions Approved for use In HVHZ:No FL11651 R3 II FL11651 2 R3 Metal Roof Panel Detail- Approved for use outside HVHZ:Yes signed.pdf Impact Resistant:N/A Verified By: Dan Kuhn,P.E.75519 Design Pressure:+N/A/-116.OPSF Created by Independent Third Party:Yes Other:-52.5 psf @ 5 3/16"o.c.fastener spacing.-116.0 psf Evaluation Reports @ 5 3/16"o.c.fastener spacing.Install per manufacturers FL11651 R3 AE FL11651 2 R3 032GulfLok 16 15- details.Not for use in HVHZ Zones. 32Plvwood NonHVHZ-sianed.Ddf Created by Independent Third Party:Yes 11651.3 1"24ga.Gulf Snap 1"Gulf Snap 24 Ga. 17"wide Roof Panel over 15/32"Plywood Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL11651 R3 II FL11651 3 R3 Metal Roof Panel Detail- Approved for use outside HVHZ:Yes sioned.odf Impact Resistant:N/A Verified By: Dan Kuhn,P.E.75519 Design Pressure: +N/A/--131.OPS Created by Independent Third Party:Yes Other:-67.3 psf @ 24"o.c.clip spacing.-131 psf @ 6"o.c. Evaluation Reports clip spacing.Install per manufacturers details.For use in FL11651 R3 AE FL11651 3 R3 1 24GuIfSnao 17 15- HVHZ Zones. 32Plvwood HVHZ-sianed.odf Created by Independent Third Party:Yes 11651.4 1"24ga.VersaLoc 1"VersaLoc 24ga 16.5"Wide Roof Panel over 15/32"Plywood Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL11651 R3 II FL11651 4 R3 Metal Roof Panel Detail- Approved for use outside HVHZ:Yes sianed.pdf Impact Resistant:N/A Verified By: Dan Kuhn,P.E.75519 Design Pressure:+N/A/-138.5PSF Created by Independent Third Party:Yes Other:-71 psf @ 24"o.c.clip spacing.-138.5 psf @ 6"o.c. Evaluation Reports clip spacing.Install per manufacturers details.For use in FL11651 R3 AE FL11651 4 R3 24VersaLoc SR 16.5 15- HVHZ Zones. 32Plvwood HVHZ-sinned.odf Created by Independent Third Party:Yes 11651.5 1"VersaLoc.032"Aluminum 1"VersaLoc min .032"Aluminum over 15/32"Plywood Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL11651 R3 II FL11651 5 R3 Metal Roof Panel Detail- Approved for use outside HVHZ:Yes silaned.pdf Impact Resistant:N/A Verified By: Dan Kuhn,P.E.75519 Design Pressure:+N/A/-101.OPSF Created by Independent Third Party:Yes Other:-63.3 psf @ 24"o.c.clip spacing.-1O1.0 psf @ 6"o.c. Evaluation Reports clip spacing.Install per manufacturers details.For use in FL11651 R3 AE FL11651 5 R3 lin 032VersaLoc HVHZ Zones. SR 16 15-32Plvwood HVHZ-sioned.odf Created by Independent Third Party:Yes 11651.6 1.5"24ga.Gulf Snap 1.5"Gulf Snap 24ga. 16"Wide Roof Panel over 15/32" Plywood Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL11651 R3 II FL11651 6 113 Metal Roof Panel Detail- Approved for use outside HVHZ:Yes signed.pdf Impact Resistant:N/A Verified By: Dan Kuhn,P.E.75519 Design Pressure:+N/A/-116.OPSF Created by Independent Third Party:Yes Other:-86.0 psf @ 24"o.c.clip spacing.-108.5 psf @ 12" Evaluation Reports o.c.clip spacing.-116.0 psf @ 6"o.c.clip spacing.Install per FL11651 R3 AE FL11651 6 R3 1.5 24GulfSnao 16 15- manufacturers detals.For use in HVHZ Zones. 32Plywood HVHZ-sioned.odf Created by Independent Third Party:Yes 11651.7 1.5"24ga.VersaLoc 1.5"VersaLoc min 24ga. 16"wide Roof Panel over 15/32" Plywood Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL11651 R3 II FL11651 7 R3 Metal Roof Panel Detail- Approved for use outside HVHZ:Yes sianed.odf Impact Resistant:N/A Verified By: Dan Kuhn,P.E.75519 Design Pressure:+N/A/-123.5PSF Created by Independent Third Party:Yes Other:-59.75 psf @ 24"o.c.clip spacing.-123.5 psf @ 12" Evaluation Reports o.c.clip spacing.Install per manufacturers details. For use in FL11651 R3 AE FL11651 7 R3 1.5 24VersaLoc 16 15- HVHZ Zones. 32Plywood HVHZ-signed.pdf Created by Independent Third Party:Yes 11651.8 2"24ga.MegaLoc Min 24 Ga.2"MegaLoc 18"wide Roof Panel over 15/32" Plywood Limits of Use Installation Instructions Approved for use in HVHZ:No FL11651 R3 II FL11651 8 R3 Metal Roof Panel Detail- Approved for use outside HVHZ:Yes signed.pdf Impact Resistant:N/A Verified By: Dan Kuhn,P.E.75519 Design Pressure:+N/A/-108.5PSF Created by Independent Third Party:Yes Other:-71.0 psf @ 24"o.c.clip spacing.-108.5 psf @ 12" Evaluation Reports o.c.clip spacing.Install per manufacturers details.Not for use FL11651 R3 AE FL11651 8 R3 24VersaLoc 18 IS- in HVHZ Zones. 32Plywood NonHVHZ-sioned.odf Created by Independent Third Party:Yes 11651.9 24 Ga.Gulf Lok Min 24 Ga.Gulf Lok 16"Wide over 15/32"Plywood Limits of Use Installation Instructions Approved for use in HVHZ:No FL11651 R3 II FL11651 9 R3 Metal Roof Panel Detail- Approved for use outside HVHZ:Yes sianed.odf Impact Resistant:N/A Verified By: Dan Kuhn,P.E.75519 Design Pressure:+N/A/-96.7PSF Created by Independent Third Party:Yes Other:-81.75 psf @ 10-1/4"o.c.fastener spacing.-96.76 Evaluation Reports psf @ 5-1/8"o.c.fastener spacing.-121.75 psf @ 5-1/8" FL11651 R3 AE FL11651 9 R3 24GulfLok 16 15- fastener spacing.-161 psf @ 5-1/8"fastener spacing.Install 32Plvwood NonHVHZ-sioned.odf per manufacturers details.Not for use in HVHZ Zones. Created by Independent Third Party:Yes 11651.10 24 Ga.Gulf Seam Min 24 Ga.Gulf Seam 16"Wide Roof Panel over 1x4 Wood Purlins over 15/32"Plywood Limits of Use Installation Instructions Approved for use in HVHZ:No FL11651 R3 II FL11651 10 R3 Metal Roof Panel Detail- Approved for use outside HVHZ:Yes sioned.odf Impact Resistant:N/A Verified By: Dan Kuhn,P.E.75519 Design Pressure:+N/A/-93.513SF Created by Independent Third Party:Yes Other:-93.5 psf @ 18"o.c.Install per manufacturers details. Evaluation Reports Not for use in HVHZ Zones. FL11651 R3 AE FL11651 10 R3 24GulfSeam 16 1x4 15- 32Plvwood Non HVHZ-sioned.odf Created by Independent Third Party:Yes 11651.11 24 Ga.Gulf Seam Min 24 Ga.Gulf Seam, 1 3/4"Snap Lock, 18"Wide Roof Panel over 15/32"Plywood Limits of Use Installation Instructions Approved for use in HVHZ:No FL11651 R3 II FL11651 11 R3 Metal Roof Panel Detail- Approved for use outside HVHZ:Yes sianed.odf Impact Resistant:N/A Verified By: Dan Kuhn,P.E.75519 Design Pressure:+N/A/-108.5PSF Created by Independent Third Party:Yes Other:-69.25 psf @ 24"o.c.clip spacing.-108.5 psf @ 12" Evaluation Reports o.c.clip spacing.Install per manufacturers details.Not for use FL11651 R3 AE FL11651 11 R3 24GulfSeam 18 15- in HVHZ Zones. 32Plvwood Non HVHZ-sianed.odf Created by Independent Third Party:Yes 11651.12 26 Ga. 5V Crimp Min 26 Ga.5V Crimp Roof Panel over 15/32"Plywood Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL11651 R3 II FL11651 12 R3 Metal Roof Panel Detail- Approved for use outside HVHZ:Yes sioned.pdf Impact Resistant:N/A Verified By: Dan Kuhn,P.E.75519 Design Pressure:+N/A/-156.5PSF Created by Independent Third Party:Yes Other:-108.5 psf @ 12"o.c.fastener spacing.-156.5 psf @ Evaluation Reports FL11651 R3 AE FL11651 12 R3 265vCrimo 15- 6"o.c.fastener spacing.Install per manufacturers details.For 32Plvwood HVHZ-sioned.odf use in HVHZ Zones. Created by Independent Third Party:Yes 11651.13 26 Ga.5V Crimp Min 26 Ga.5V Crimp over 15/32"Plywood Limits of Use Installation Instructions Approved for use in HVHZ:No FL11651 R3 II FL11651 13 R3 Metal Roof Panel Detail- Approved for use outside HVHZ:Yes siioned.pdf Impact Resistant:N/A Verified By: Dan Kuhn,P.E.75519 Design Pressure:+N/A/-131.PSF Created by Independent Third Party:Yes Other:-94.25 psf @ 16"o.c.fastener pattern.-131.0 psf @ Evaluation Reports 16"o.c.fastener pattern.Install per manufacturers details. FL11651 R3 AE FL11651 13 R3 265vCrimo 15- Not for use in HVHZ Zones. 32Plvwood NonHVHZ-signed.pdf Created by Independent Third Party:Yes 11651.14 26 Ga.5V Crimp Min 26 Ga.5V Crimp Roof Panel over Ix4 Wood Purlins over 15/32"Plywood Limits of Use Installation Instructions Approved for use in HVHZ:No FL11651 R3 II FL11651 14 R3 Metal Roof Panel Detail- Approved for use outside HVHZ:Yes sianed.odf Impact Resistant:N/A Verified By: Dan Kuhn,P.E.75519 Design Pressure:+N/A/-156.SPSF Created by Independent Third Party:Yes Other:-108.5 psf @ 12"o.c.fastener spacing.-156.5 psf @ Evaluation Reports 6"o.c.fastener spacing.Install per manufacturers details.For FL11651 R3 AE FL11651 14 R3 265vCrimp 1x4 15- use in HVHZ Zones. 32Plvwood NonHVHZ-sianed.pdf Created by Independent Third Party:Yes 11651.15 26 Ga.Gulf Lok Min 26 Ga.Gulf Lok 16"Wide Roof Panel over 15/32"Plywood Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL11651 R3 II FL11651 15 R3 Metal Roof Panel Detail- Approved for use outside HVHZ:Yes sianed.pdf Impact Resistant:N/A Verified By: Dan Kuhn,P.E.75519 Design Pressure:+N/A/-161.OPSF Created by Independent Third Party:Yes Other:-63.5 psf @ 5 3/16"o.c.fastener spacing.-121.75 Evaluation Reports psf @ 5 3/16"spacing.-161.0 psf @ 5 3/16"o.c.fastener FL11651 R3 AE FL11651 15 R3 26Gulfl-ok 16 15- spacing.Install per manufacturers details.For use in HVHZ 32Plvwood HVHZ-sioned.odf Zones. Created by Independent Third Party:Yes 11651.16 26 Ga.Gulf Lok Min 26 Ga.Gulf Lok 16"Wide Roof Panel over 15/32"Plywood Limits of Use Installation Instructions Approved for use in HVHZ:No FL11651 R3 II FL11651 16 R3 Metal Roof Panel Detail- Approved for use outside HVHZ:Yes sioned.odf Impact Resistant:N/A Verified By: Dan Kuhn,P.E.75519 Design Pressure: +N/A/-63.5PSF Created by Independent Third Party:Yes Other:-63.5 psf @ 5 3/16"o.c.fastener spacing.-121.75 Evaluation Reports psf @ 5 3/16"fastener spacing.-161 psf @ 5 3/16"fastener FL11651 R3 AE FL11651 16 R3 26GulfLok 16 15- spacing.Install per manufacturers details.Not for use in 32Plywood NonHVHZ-signed.pdf HVHZ Zones. Created by Independent Third Party:Yes 11651.17 26 Ga.GulfPBR Min 26 Ga.Gulf PBR Roof Panel over 15/32"Plywood Limits of Use Installation Instructions Approved for use in HVHZ:No FL11651 R3 II FL11651 17 R3 Metal Roof Panel Detail- Approved for use outside HVHZ:Yes sianed.odf Impact Resistant:N/A Verified By: Dan Kuhn,P.E.75519 Design Pressure:+N/A/-154.7PSF Created by Independent Third Party:Yes Other:-59.25 psf @ 24"o.c.fastener pattern.-154.75 psf @ Evaluation Reports 12"o.c.fastener pattern.Install per manufacturer details.Not FL11651 R3 AE FL11651 17 R3 26GulfPBR 15- for use in HVHZ 32Plvwood NonHVHZ-signed.pdf Created by Independent Third Party:Yes 11651.18 26 Ga.GulfPBR Min 26 Ga.GulfPBR Roof Panel over 1x4 Wood Purlins over 15/32"Plywood Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL11651 R3 II FL11651 18 R3 Metal Roof Panel Detail- Approved for use outside HVHZ:Yes sianed.odf Impact Resistant:N/A Verified By: Dan Kuhn,P.E.75519 Design Pressure: +N/A/-151.7PSF Created by Independent Third Party:Yes Other:-100.5 psf @ 24"o.c.fastener spacing.-151.75 psf @ Evaluation Reports 12"fastener spacing.Install per manufacturer's details.For FL11651 R3 AE FL11651 18 R3 26GulfPBR 1x4 15- use in HVHZ Zones 32Plvwood HVHZ-sianed.Ddf Created by Independent Third Party:Yes 11651.19 26 Ga.GulfPBR Min 26 Ga.GulfPBR over 15/32"Plywood Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL11651 R3 II FL11651 19 R3 Metal Roof Panel Detail- Approved for use outside HVHZ:Yes signed.pdf Impact Resistant:N/A Verified By: Dan Kuhn,P.E.75519 Design Pressure: +N/A/-154.7PSF Created by Independent Third Party:Yes Other:-60.5 psf @ 24"o.c.fastener spacing.-154.75 psf @ Evaluation Reports FL11651 R3 AE FL11651 19 R3 26Gu)fPBR 15- 12"D.C.fastener spacing.Install per manufacturer's details. 32Plvwood HVHZ-sianed.odf For use in HVHZ Zones. Created by Independent Third Party:Yes 11651.20 26 Ga.GulfPBR Min 26 Ga.GulfPBR over 1x4 Wood Purlins over 15/32" Plywood Limits of Use Installation Instructions Approved for use In HVHZ:No FL11651 R3 II FL11651 20 R3 Metal Roof Panel Detail- Approved for use outside HVHZ:Yes sianed.odf Impact Resistant:N/A Verified By: Dan Kuhn,P.E.75519 Design Pressure:+N/A/-151.7PSF Created by Independent Third Party:Yes Other:-94.25 psf @ 24"o.c.fastener spacing.-151.75 psf @ Evaluation Reports 12"fastener spacing.Install per manufacturer's details.Not FL11651 R3 AE FL11651 20 R3 26GulfPBR 1x4 15- for use in HVHZ Zones 32Plvwood NonHVHZ-sioned.odf Created by Independent Third Party:Yes Go to Page 0110 Pagel/20 0 Back Next Contact Us::2601 Blair Stone Road.Tallahassee FL 32399 Phone:850487-1824 The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released In response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mall.If you have any questions,please contact 850.487.1395.-Pursuant to Section 455.275(1), Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address If they have one.The emaiis provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: ®® ®P Q A Credit Card _._._.. Safe