HomeMy WebLinkAbout20-1037 T; i ` (111�Ufl City of Zephyrhills PERMIT NUMBER a — — j� ry' 5335 Eighth Street Zephyrhills, FL 33542 ELCMISC-001037-2020 Phone: (813)780-0020 Fax: (813)780-0021 Issue Date: 12/04/2020 Permit Type: Electric Service Replacement/Misc r S t Ad eedqProperyNum _ 32 25 21 0100 01800 0060 7161 Boxer Round PI MOM O ner Informattony� Permitglnforma Contractor Information Name: MILAGROS IRIZARRY-BATISTA Permit Type:Electric Service Replacement/M Contractor:VIVINT SOLAR DEVELOPEF Class of Work:Add/Alter Residential LLC Address: 7161 Boxer Round PI Building Valuation:$4,862.00 ZEPHYRHILLS,FL 33541-3900 Electrical Valuation:$19,448.00 Phone: (929)408-1468 Mechanical Valuation: � /� Plumbing Valuation: VD ` (�y Total Valuation:$24,310.00 Total Fees:$302.33 1' Amount Paid:$302.33 `\ Date Paid:12/4/2020 11:40:57AM •waa �++.-gig: :max. ,�_ t. P�roject�Description , --m ,;� ., ^a .�..4 ;R, INSTALLATION ROOF MOUNT PV SOLAR Application.Fees :, `p ,. :. 3 . Electrical Plan Review Fee $68.62 Plan Review Fee $32.16 Building Permit Fee $64.31 Electrical Permit Fee $137.24 REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each subsequent reinspection. Notice: In addition to the requirements of this permit,there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permit required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner:Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications add fee Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. ,q)Q L-"rn CONTFACTOR SIGNATURE PE IT OFFICE PERMIT dxPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER ' INSTR#2020204910 OR BK 1 0228 PG 1137 Page 1 of 1 12/04/2020 10:09 AM Rcpt:2233639 Rec:10.00 DS:0.00 IT:0.00 Nikki Alvarez-Sowles,Esq.,Pasco County Clerk&Comptroller Pen it No. ParcelIDNo 32-Zd'2l-0100 -0/700 -019(L0 NOTICE OF COMMENCEMENT swocf F(orlda County of Pasco . THE UNDERSIGNED hereby gives notice that improvement will be made to certain real property,and in accordance with Chapter713,Florida Statutes, the following information b provided in this Notice of Commencement 1. Description of Property:Parcel Identification No. Street Address: G 1 WOE G OL/ t R Y r 9 2 Gederai Description of improvement Installation of a roof-mounded solar photovoltaI6 system 3. Owner Informatip or Lessee information if the Lessee contracted forth i eme.- M; 'j161 Mx-e-( Ceund, PL FL Address . City State Interest In Property: Name of Fee Simple Titleholder: . (If different from Owner listed above) 4. Corrba� Vivint Solar Developer,LLC coy Name �� 51100 W Hanna Ave Tampa F(L 3VS34 �1 . Address City Slate f �'•• o�� ✓ ` 4 Contractor's Telephone No.: (813)359-0634 -+6 :.�'A S. Surety: _ ; s �.f.- Name Address City Stem .. NK':, �m ryS "'F41 Amount of Bonds Telephone No.: 8. Larder. Name Address City Larder's Telephone No.: `-"3�' 41 7. Persons within the State of Florida designated by the owner upon whom notlees or other dooumerrte may be served as provided by Section 713.13(1)(a)(7),Florida Statutes: Name Address City State Telephone Numberof Designated Person: e. In addition to himself.the owner desigrmtes of to receive a copy of the Lienoes Notice as provided in Section 713.13(1)(b),Florida StaNtes. U W Telephone Number of Person or Entity Designated by Owner. Q z 0 J W U) LtJ LL• U) O —U 9. Expiration date of Notice of Commencement(the expiration date may not be before the complmi of co/n�'sstrtrpp�grYiren am}/,Hnal paym�/el1yd ro Me W � U contractor,but wilt be one year from the date of recording unless a different date is specified): I VL 2 Jl 7 c z U O F•- }' WARNING TO OMER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF I*mmENCEME rr 0 ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13, FLORIDA STATUTES, AND CAN (a O O = Q � f2 RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE 4x O Q LLl RECORDED AND POSTED ON THE J08'SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING,CONSULT (; tJJ W O (n U Q WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. rr _ ? J Under penalty of perjury,1 declare that I have read the foregoi notice of co ecernenlea at the stated therein are true to the Crest O ~ Q ¢ Y of my ImoWedge and belief. - L J O O W COUSTANTY OF P RASCO a LU O d U Signature erar arOwn Authorized p Q O �.Q �. O(f�fio�er/((D��inxtor/Partne alter V = U U Z l`u�t0. f H J Q J SgnaWs Office 0 U m Q 0 0) �tL� /�� a� (� �[ � Z O O The foregoing instmmentwas acknowledged before_me�ra day of �0 2ous�by/x\)I f�7 t]''V�V�� 'f I_ (y = Q N as OW (type of authority,e.g.,officer,trustee,attorney in fact)to" W U O } Q W (name of pa It of wham i ecuted), IL Q Q Q Personalty Known❑Qa Produced Identifiea' Notary Signature '� ~ Z W �D to Q O Type of Identification Produced Name(Print) Q ram/ — W =U W _ N � LL IZ- Y o3 z m ==11=4 ublic State of Fltlrkla BefboneiAAAA OV4 rdett m GG 963833 wpdatelbarnoticeoorrarte„eemen[yc053048 _-_� __—_r__�________ __.._.___rr••---�•• ---- Building Department Oahe Received �7 /3Ill 4 O`7 Owners Name EaMPOL 7 -r,2pr2/1R y Owner Phone Number Owners Address L) /'L• Owner Phone Number Fee Simple Titleholder Name Owner Phone Number Fee SimpleriitleholderAddress — r JOB ADDRESS �y—�� LOT# SUBDIVISION !r vcAmb0 po9V C . PARCEL Itw Z' S--21-U1 0 0- O l O DO• Q 0(a d �'-- (OBTAINED FROM PROPERTYTA%NOTICE WORK PROPOSED a NEW CONMR ADDIALT = SIGN = DEMOLISH INSTALL REPAIR PROPOSED USE = SFR 0 COMM = OTHER TYPE OF CONSTRUCTION = BLOCK 0 FRAME = STEEL = DESCIUPTION OF WORK ILMSERLIAEMAI OF AQ0Qr-HQ()AJ(Z7,b BUILDING SIZE SO FOOTAGE HEIGHT 3 y S' BUILDING Is fe 2 'ff VALUATION OF p ELECTRICAL $ 0 AMP S FROG ERGY 0 W.R.E.C. `. = -Ive PLUMBING n q_ =MECHANICAL MEGHANICAL 1 =GAS = ROOFING 0 S CIALTY ER FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES NO L' BUILDER COMPANY WE-Zr SIGNATURE REGISTERED Y/ N I FEECURREA Y!N Address ® License# G3 ELECTRICIAN COMPANY l SIGNATURE REGISTERED I Y/ N I FEE CURREN LILN AddressSLIM W- aP-A(AJffLicense#52 136007Y 0 PLUMBER COMPANY SIGNATURE REGISTERED Y/ N FEECURREn Y/N Address License# MECHANICAL COMPANY SIGNATURE REGISTERED I Y/ N I FEECURl Address License# DER COMPANY SIGNATURE REGISTERED Y/ N FEECURREA LILN Address License# 1111111111111111111111111111111111111111111111111111111111111111111 ` RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Fortes;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 du mpster,Site Work Permit for subdivisionsllarge projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Fortes.R-O-W Permit for new construction. Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Storrnwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster_Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. —PROPERTY SURVEY required for all NEW construction. Drreetions. Fill out application completely. Owner&Contractor sign back of application,notarized If over$2500,a Notice of Commencement is required. (A/C upgrades over$7500) Agent(for the contractor)or Power of Attorney(for the owner)would-be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroafs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage) Driveways-Not over Counter if an public roadways..needs ROW NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed"restrictions! which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work,they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law,both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work,they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor-or contractors, he is advised to have the contractor(s) sign portions of the'contractor Bloch'of this application for which they will be responsible. if you,as the owner sign as the contractor,that may be an indication that he is not property licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACTIUTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings,change of use in existing buildings,or expansion of existing buildings,as specified in Pasco County Ordinance number 89-07 and 90,-07,as amended. The undersigned also understands,that such fees,as may be due,Will be identified at the time of permitting. it is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a"certificate of occupancy"or final power release. If the project does not involve a certificate of occupancy or final power release,the fees must be paid prior to permit issuance. Furthermore,9 Pasco County Water/Sewer Impact fees are due,they must be paid prior to permit issuance in accordance With applicable Pasco County ordinances. CONSTRUCTION UEN LAW(Chapter 713,Florida Statutes,as amended): If valuation of work is$2,500.00 or more,I certify that 1, the applicant, have been provided with a copy of the *Florida Construction Lien Law—Homeowner's Protection Guider prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant Is someone other than the"owner",I ceirtffy that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner"prior to commencement CONTRACTOR'S/OWNER'S AFFIDAVIT. I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction,zoning and land development Application is hereby made to obtain a permit to do work and installation as indicated. I certify that,no work or installation has commenced prior to issuance of a permit and that all work Will be performed-to meet standards of all laws regulating construction, County and City codes,zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work,and that it is my responsibility to identify,what actions I must take to be in complian6i. Such agencies include but are not limited to, Department of Environmental Protection-Cypress Bayheads,Wetland Areas and Environmentally Sensitive Lands,Water/Wastewater Treatment - Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. . I - Army Corps of Engineers-Seawalls,Docks,Navigable Waterways. - Department of Health &Rehabilitative Services(Environmental Health Unit-Welts, Wastewater Treatment, Septic Tanks. - US Environmental Protection Agency-Asbestos abatement - Federal Aviation Authority-Runways. I understand that the following restrictions apply to the use of fill: - Use of fill is not allowed in Flood Zone Nr unless expressly permitted. - If the fill material is to be used in Flood Zone 'A7, it is understood that a drainage plan addressing a "compensating volume"will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. - If the fill material is to be used in Flood Zone"X in connection with a permitted building using stem Wall construction,I certify that fill will be used only to fill the area within the stem wall. - If fill material is to be used in any area, I certify,that use of such fill Will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties,the owner may be cited for violating the conditions of the building pennit issued under the attached permit application,for lots less than one(1) acre which are elevated by fill,an engineered drainage plan is required. If I am the AGENT FOR THE OWNER,I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing,signs,wells, peals,air conditioning,gas,or other installations not,specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate,cancel,after,or set aside any provisions of the technical codes,nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans,construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance,or if work authorized by the permit is suspended or abandoned for a period of six(6)months after the time the work is commenced. An extension may be requested,in writing,from the Building Official for a period not to exceed ninety(90)days and will demonstrate justifiable cause for the extension. If work ceases for ninety(90)consecutive days,the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS T UR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENgW OR AN ATT012EYORE RECORDING YOUR NOTICE OF COMMENCEMENT. FLORIDA JURAT(F. 1 .03) OWNER OR AGEN CONTRACTOR ornlo or affirm to this Subscribed and swam to(or affirmed)before me this by ME-J.3.8p[Sami own to me or hasthave produced Who Ware personally ImI to me or ttasihave,produced as identification. as identification. _140tary Public Notary Public Commission NO. Commission NCL* Name of Notary typed,printed or stamped Name of Notary typed,printed or stamped ,,o NNotafypuW5t9Ieo(FlI a James Quillen My Commission HH 012750 Fodes 09125t2024 vivant Solare 1800 W Ashton Blvd. iill Lehi, UT 84043 A sunrun COMPANY J.Matthew Walsh, PE Kirk M.Nelson, SE Samuel Brown, PE- Civil Director of Engineering Structural Engineering Structural Engineering james.walsh@sunrun.com kirk.nelson@sunrun.com sam.brown@sunrun.com November 03, 2020 Re: Structural Engineering Services Irizarry Structure 7161 Boxer Round PI, Zephyrhills, FL S-6496067; FL-01 To Whom It May Concern: We have reviewed the following information regarding solar panel installation on the roof of the above referenced structure: 1. Site Visit by a representative from our office under my supervision identifying specific interior and exterior site information including the condition of the existing roof system and the size, spacing, and condition of existing structural framing members. Information gathered during the site visit includes photographs, sketches, and verification forms. 2. Design drawings of the proposed PV System layout, including details to mount the new solar panels to the existing roof. Based on the above information, we have evaluated the structural capacity of the existing roof system to support the additional loads imposed by the solar panels and have the following comments related to our review and evaluation: A. Description of Structure: The existing structure has typical wood framing construction with a maximum of two layers of composite shingle roofing. All wood material utilized for the roof system is assumed to be Southern Pine#2 or better with standard construction components. The designed areas of the home consist of the following framing methods: • Roof Section: Prefabricated trusses at 24"on center. Survey photos indicate that there was free access to verify the framing size and spacing. • Roof Section: Prefabricated trusses at 24"on center. Survey photos indicate that there was free access to verify the framing size and spacing. • Roof Section: Prefabricated trusses at 24" on center. Survey photos indicate that there was free access to verify the framing size and spacing. • Roof Section: Prefabricated trusses at 24" on center. Survey photos indicate that there was free access to verify the framing size and spacing. B. Loading Criteria 14.66 PSF= Dead Load (roofing/framing) 3.00 PSF= Dead Load (solar panels/mounting hardware) 17.66 PSF=Total Dead Load 20 PSF= Roof Live Load (based on local requirements) Wind speed of 145 mph (based on Exposure Category D-the total area subject to wind uplift is calculated for the Interior, Edge, and Corner Zones of the dwelling.) vivant®Sol ara Page 1 of A 'sunrun COMPANY C. Required Structural Repairs The analysis performed has indicated that the existing roof will require the following repairs prior to installation of the photovoltaic array: Hip/Cross-Slope Framing - The mounting hardware is not designed to support the array with the roof framing running horizontally (cross-slope). At locations where mounting hardware will be installed, install blocks between existing framing members in accordance with detail SK-7. D. Solar Panel Anchorage 1. Installation shall proceed in accordance with the applicable guidelines and recommendations indicated below. If, during solar panel installation, the roof framing members appear unstable or deflect non-uniformly, our office should be notified before proceeding with the installation. • SnapNrack Installation Manual, which can be found on the SnapNrack website (https://snapnrack.com/). 2. The solar panels are 1%' thick. At no. time will the panels be mounted higher than 10" above the existing surface of the roof. 3. The following mounting types shall be used. Please refer to the mounting details for the associated mounting method requirements. Based on our evaluation, the uplift demand is less than the maximum allowable per mount and therefore is adequate. • RL-U SpeedSeal: (1) 5/16" lag screw. Pullout capacity based on National Design Specifications (NDS) of timber construction specifications for Southern Pine is 235 Ibs/inch penetration. I 4. Fasteners are installed to meet industry standards and this document satisfies requirements in 2017 FBC 2303.4.5 verifying that the fasteners will not adversely affect the roof framing. 5. The maximum allowed spacing was calculated for the Wind Speed shown in paragraph B above, using the wind load uplift procedures of ASCE 7-10. These spacing requirements apply to all mount types indicated above. The following values have been verified by in-house testing and the mounting hardware manufacturers' data, which are available upon request. Panel support connections should be staggered, where possible, to distribute load to adjacent members. Modules in Landscape Modules in Portrait Roof Zone Interior Ede Corner Interior Ede Corner Max Vertical Spacing in 40 40 40 66 66 66 Max Horizontal Spacing in 48 48 48 37 35 37 Cantilever in 16 16 16 12 12 12 E. Summary Based on the above evaluation, with the structural repairs completed as prescribed and appropriate panel anchors being utilized, the roof system designed on will adequately support the additional loading imposed by the solar panels, if installed correctly. This evaluation has been performed for the structural elements only and verifies that they are in conformance with the 2017 Florida Building Code-Residential 6th Edition, current industry standards and practice, and the information supplied to us at the time of this report. vivint®S®lare Page 2of8 A SUflfl n COMPANY If there are any questions regarding the above, or if more information is required, please contact me. Regards, \\\\\��P,��1-IE6►Y J. Matthew Walsh, PE •,S FL License No. 84923 = No 84y�� ; �i STATE OF ;40 z 1/111111 11/03/2020 vivint®Solar° Page 3of8 A sunrufl COMPANY �' �I f • Blvd. s Y Lehi, UT 84043 AsunrunCOMPANY Nelson,J. Matthew Walsh, PE Kirk M. • Directorof • • Structural Engineering Structural Engineering james.waish@sunrun.com • r ' �M1.i J' ;��.T'!���i-'M"' - ::ia�wr=...;.,,,i-�w.rwn...wr.'•.r,�-�w,... vivint.Sol •T R�'� ..Ir �3+ � F�.. 4„ n .l,. f r� Y � �pZ(yZn '�� .. ? , *•t } ,R- ��+. w _. 1rµ��'�• f ,..i y,. ., �O I l2 �-dF �'�+.,*; r,"li^F��,. f• � �,w •� ...� �;. mil.+t f i p♦ �:,;�'1ak�x' �"�3w,, '• "..Yt���t+�'�.wxa�k . +a€q '+A• ct„w... „ � h"�L • Page 4 of 8 AsunrunCOMPANY C • E r• t •�'� � y f y .. �• . � � fps% 3 � l f + µ Y needed vivint Solar° 180011Lehi, T 4043 • Lehi, UT 84043 A sunrun COMPANY J. Matthew Walsh, PE Kirk M.-Nelson, SE Samuel Brown, PE- Civil Director of Engineering Structural Engineering Structural Engineering james.walsh@sunrun.com kirk.nelson@sunrun.com sam.brown@sunrun.com a s r^ y �ti.r 1 4q 11'f } vivi 1t.S®Iarg Page 6of8 A sunrun COMPANY • • 0 1800 W Ashton Blvd. vivint•S®lar Lehi, UT 84043 A sunrun COMPANY J. Matthew Walsh, PE Kirk M. Nelson, SE Samuel Brown, PE- Civil Director of Engineering Structural Engineering Structural Engineering james.walsh@sunrun.com kirk.nelson@sunrun.com sam.brown@sunrun.com •F :a. r if Ii:i V '• 31"1 - �+ vivint.S®lar° Page 7of8 A sunrun COMPANY NOTES 1. WHERE BLOCKING TO BE ADDED,IF THE HORIZONTAL DISTANCE BETWEEN SURROUNDING CROSS-SLOPE FRAMING ' IS GREATER THAN 4%BLOCKING SHALL BE THE SAME SIZE AS THE (E) ROOFING MATERIAL CROSS-SLOPE FRAMING MEMBERS. 2. ADDED BLOCKING MUST USE CLIPS ON EACH END,AS SHOWN.TOE NAIL (E)CROSS-SLOPE CONNECTIONS ARE NOT ALLOWED. FRAMING, TYP. —� (E)- EXISTING - %� (N)- NEW (E) ROOF SHEATHING HE W � I �%CENSF- `S1 N 84v23 STATE OF W (N)2X4 MIN. @ MOUNTING FEET f - LOCATIONS, SEE NOTE 1. VIVI11t.SOIar i (N) SIMPSON A34 ANGLE 385.715.6237 WITH (8) SIMPSON N8 NAILS (OR EQUIV.), TYP. HOME UPGRADE STRUCTURAL DETAIL I i CROSS SLOPE FRAMING VERSION: - 1 (NOT TO SCALE) DATE: 8/24/2020 DRAWN BY:DJH vivint.S®lar% Page 8of8 A sunrun COMPANY Ashton Blvd. v'vi tsSolar 1800 w hi, UT 84043 A Sunrufl COMPANY J. Matthew Walsh, PE Kirk M. Nelson, SE Samuel Brown, PE-Civil Director of Engineering Structural Engineering Structural Engineering james.wa/sh@sunrun.com kirk.nelson@sunrun.com sam.brown@sunrun.com Structural Design Criteria Project Address Date: November 3,2020 Irizarry Residence 7161 Boxer Round PI Zephyrhills,FL S-6496067 \\���P,�i H E W bk Residence \�� �,, Risk Category II 1• Roof Area 1917 sf 8-4y /3 + _- Upper Floor Area 0 sf Number of Stories 1 STATE OF Mean Roof height 15 ft r/% 0'. k/ Upper Floor height 0 ft �i, �`�'.'QC OR10P,'��� � Location Parameters �s`S10NAL Latitude 28.261389 ���1/>✓2�UYAaQ1\��\\ Longitude -82.226111 Site Class D(Default) Risk Category II Existing Gravity Parameters Roof Dead Load 5 psf Composite Shingle 2 psf 3/4"Plywood Sheathing 2 psf Roof Framing @ 24 in.o.c. 3 psf Ceiling,Mechanical,Electrical 2 psf Miscellaneous 15 psf TOTAL Roof Live Load 20 psf Wall Dead Load Ground Snow Load 0 psf 8 ft Wall Height Flat Roof Snow Load 0 psf 300 ft Wall Length 12 psf Wall Weight New Gravity Parameters Roof Dead Load 3.00 psf Solar Panel Weight Roof Live Load with Solar Panels 0 psf Roof Slope Factor 0.8 Roof Slope Factor(ASCE 7-10 Fig.7-2b) Roof Snow Load 0 psf ASCE 7-10 Eq.7.4-1 Seismic Parameters SS= 0.067 g 0.2 sec Spectral Response Acceleration S1 = 0.034 g 1.0 sec Spectral Response Acceleration Fa= 1.600 g Site Coefficient from ASCE 7-10,Table 11.4-1 F„= 2.400 Site Coefficient from ASCE 7-10,Table 11.4-2 SDS= 0.071 g Short Period Design Spectral Acceleration SD1 = 0.054 g 1 Second Period Design Spectral Acceleration vNint.Solar° Page 1 of 4 A Suflrufl COMPANY Wind Parameters Wind Speed 145 mph Exposure Category D Roof Angle, Q 22.0 deg Product Information No.of Panels 34 Weight 3.00 psf including mounting system Installed Area 617.2 ft2 No.of Connectors 45 Total Existing Roof Load=Roof Dead Load+(Roof Live Load or Snow)x Spacing 69.32 plf Total New Roof Load=Roof Dead Load+Added Dead Load+(Roof Live Load or Snow)x Spacing) 35.32 plf Change in Demand=(Total New Load-Existing Load)/Existing Load -49.05% Total New Gravity Loads are less than Existing Loads. OK 2015 IEBC Section 707.2 states: "Where addition or replacement of roofing or replacement of equipment results'in additional dead loads,structural components supporting such reroofing or equipment shall comply with the gravity load requirements of the International Building Code. EXCEPTION 1.Structural elements where the additional dead load from the roofing or equipment does not increase the force in the element by more than 5 percent." 2015 IRC Section AJ501.4 states: "The minimum design loads for the structure shall be the loads applicable at the time the building was constructed,provided that a dangerous condition is not created.Structural elements that are uncovered during the course of the alteration and that are found to be unsound or dangerous shall be made to comply with the applicable requirements of this code." 2017 FBC Section AJ104.1 states: "Detached one-or two-family dwellings that are not irregular buildings under Section R301.2.2.2.5 and are not undergoing an extensive reconstruction shall not be required to be evaluated." Page 2 of 4 vivint.Solar' A sunrufl COMPANY vivint.S®lar° 18®®1NAshton Lehi, UT 840434043 A SUf1Irun COMPANY J.Matthew Walsh, PE Kirk M. Nelson, SE Samuel Brown, PE-Civil Director of Engineering Structural Engineering Structural Engineering james.walsh@sunrun.com kirk.n els on as un run.c o m sam.brown@sunrun.com Mount Spacing Calculation ASCE 7-10 Simplified Procedure for Components and Cladding NDS Section 12 [CC Code Cycle 2015 Wind speed (V) 145 mph Exposure Category D Roof Slope (0) 22.0 deg Effective Wind Area 20 sf Least Horizontal Dimension 30.00 ft Adjustment Factor(It) 1.47 Topographic(Kt) 1 Panel Dead Load TO 3 psf Ground Snow Load 0 psf Flat Roof Snow Load (pf) 0 psf ASCE 7-10 Eq. 7.3-1 Slope Factor(CS) 0.80 ASCE 7-10 Fig. 7-2b Panel Snow Load 0 psf PfCS Total Dead Load (D) 3 psf Panel Dead Load + Roof Snow Load Portrait Landscape Vertical Spacing (L) 67 in 39 in Based on length of the panel Wind Pressure Zone 1 Zone 2 Zone 3 Lookup Pressure (Pnet30) 31 psf 49 psf 89 psf ASCE 7-10 Fig. 30.5-1 Uplift Pressure W 46 psf 72 psf 131 psf A*Kzt*Pnet30 Fastener Type 5/16 Yield Equations NDS Table 12.3.1A Diameter 5/16 in I m 656 Ibs Fasteners 1 1 s 1238lbs Embedment(Dpen) 2 1/2 in II 364 Ibs Load Duration (Cd) 1.6 III m 377 Ibs Pullout per Inch (W) 235 lb/in III s 394 Ibs IV 340 Ibs Uplift Capacity 939 Ibs DpenCdW Shear Capacity 340 Ibs Based on equations from NDS 12.3.1A vivint.Solar° Page 3 of 4 A sunrun COMPANY vivint.Solaro 1800 W Ashton Blvd. Lehi, UT 84043 4043 A SUf�run COMPANY J. Matthew Walsh, PE Kirk M. Nelson, SE Samuel Brown,_PE-Civil Director of Engineering Structural Engineering Structural Engineering james.walsh@sunrun.com kirk.nelson@sunrun.com sam.brown@sunrun.com Mount Types: Uplift Shear Fasteners (Capacities based on manufacturer testing) RL-U S eedSeal 443 Ibs 238 Ibs 1 Fastener Capacity 939 Ibs 340 Ibs Controlling Capacity 443lbs 238lbs Portrait Zone 1 Zone 2 Zone 3 Uplift 37 in 35 in 37 in Shear 456 in 686 in 1372 in Capacity Manufacturer or AHJ 48 in 48 in 48 in L*SIN(6)*D Controlling Spacing 37 in 35 in 37 in Landscape Zone 1 Zone 2 Zone 3 Capacity Uplift 63 in 59 in 64 in L*0.6(D-W) Shear 782 in 1176 in 2352 in Capacity Manufacturer or AHJ 48 1n 48 in 48 in L*SIN(A)*D Controlling Spacing j 48 in j 48 in j 48 in Tributary Area (Atr;b) Zone 1 Zone 2 Zone 3 Mount Spacing *Vertical Spacing Portrait 17 sf 11 sf 6 sf Landscape 13 sf 9 sf 4 sf Demand in Uplift Acmb*0.6(Pd-W) Portrait 44311bs 44311bs 443lbs Landscape 338lbs 359lbs 333lbs Capacity in Uplift 443 Ibs 443 Ibs 443 Ibs Max Utilization=1.00 Demand in Shear Amb*SIN(A)*D Portrait 19lbs 12lbs 6lbs Landscape 15lbs 10lbs 5lbs Capacity in Shear 238 Ibs 238 Ibs 238 Ibs Max Utilization=0.08 vivint.Solar' Page 4 of 4 A sunrun COMPANY ;anc otar s Canad M0t4®pERC module H,®pCK H19h density P►l.�-'BL 3201N 340,w0'33513A0Ms CS,IN'320 W- MARE pOwEB area, warranty on materials ht absorption roduct ize the lig to 20.16 ojo 15 enhanced P Maxtor t and w°rkmanship* uP zo module efflciencY uP 20.1610 years F erature coefficient °o tPmaxl• ^,.°" l ow tem 1p C linear power°utPut warranty* ; �� arranty statement. �, years ................ solariimttedW ....._......-- '""" a licableCanadian �..- tolerance to the PP .According "'..•... shading . ................. } getter ,nFICAtE MANAGEMENT SYSS' 9ementsystem management system safety I50 9001:2015 t Qual ndards for environd,, for ocwPat1p°al health&mental m MORE RELIABLE ISO 14001:20151 to international standards oHSaS 18001:z 00-7 1ernal current CT CERRpjCATES* �oweC snot spot temperature PRODV q VDE t CE t MC5 U5)t FSEC NS Florida 1 lowerh C61730: CEClisted( ton. IEc 61215 t IE etformance: in srrfall reg c 61215 P �pE t iEG 62716:VDE risk limited u11703 t IE tli cSA I IEC 61701 ED2' Cell crack module reliab� ty uu17o3: /� _ Qenhance the mod TakeV e'Way V ''C R arkets,Please 1e Yo t e°ur u to 5404 Pa. pVE Cous� �� s e licab snow load P * Uirementsindtcftcce flcatesaPP Keahl u to 2400 Pe o iricatton"ta%lve for the P be used. 3e© wind load p different cries rePYe�he P ucts are service As there are Solar s es re, ....Co^.. rod high focal cans "COmmitted to PrOvtdin9 In the region products ................. 5 t P ....... 5 C 15 quality Ot AR IN Solar system solutions an tier for CANp,01P cts. le supP quality solar Pro nd the world.NO.1 Module Customer Insight Usto ers arou in IKS d manufacturer GustoerfOrmanCe.19 c, ratio er an d the world and Pe ding Pn Per�3g Gw d ployed around survey-Ps a lea of solar m odu►es with ................ sinceCA ................. ................. solar.com anual. 5°Iar.GOm. suPpof t@canadian It information.Please refer to clarion. Canada, Nvffi.canadian t For data ....- ... 1 E6. CAN .............OLARINC ontanoN1 ....Np'D�N SO west,Guelph 545 5peedvale Avenue ENGINEERING DRAWING(mm) CS1 H-330MS/I-V CURVES Rear View Frame Cross Section A-A A A 12 __ _ ___ __________ ____ "- 35 __�• 35 _ - 10 --" -"______-_-_.-"__---______-__ 10 __ ____________________________ __ -_9 -.___ _ __ -_""_ "_--_ - - 9 un a-140 m 7._--- ---- - -- --- 7 --'------ ---- MeunlingFY - -- - 5 5 _- _ ____ ____ _________ 4 __ _- 4 f - .. Mounting Hole 3 3 2 --- - ----- 2 --- --- -------- -- - ------ -. - ° v ° - v 15 20 25 30 35 40 45 5 5 10 15 20 25 30 35 40 45 50 5 10 0 1000 W/m' 5-c E A:__A i I ® BOO w1w 25'C i 600 MW 45-C 400 W/m' 65-C 992 � 200 W/m' ELECTRICAL DATA STC* MECHANICAL DATA CS1H 320MS 325MSj 330MS 335MS 340MS Specification Data Nominal Max.Power(Pmax) 320 W 325 W 1 330 W 335 W 340 W Cell Type Mono-crystalline Opt.Operating Voltage(Vmp) 36.2 V 36.6 V 137.0 V 37.4 V 37.8 V Dimensions 1700 x992 x35 mm Opt.Operating Current(Imp) 8.85 A 8.88 A 8.92 A 8.96 A 9.00 A (66.9 x39.1 x 1.38 in) Open Circuit Voltage(Voc) 44.0 V 44.1 V 44.2 V 44.3 V 44.5 V Weight 19.2 kg(42.3 Ibs) Short Circuit Current(Isc) 9.41 A 9.45 A 9.49 A 9.53 A 9.57 A Front Cover 3.2 mm tempered glass Module Efficiency 18.98% 19.27%1 19.57%19.86% 20.16% Frame Anodized aluminium alloy Operating Temperature -40°C-+85°C J-Box IP68,3 bypass diodes Max.System Voltage 1000V(IEC/UL) Cable 4.0 mm2(IEC),12 AWG(UL) TYPE 1 (UL 1703)Ior Cable Length 1350 mm(53.1 in) Module Fire Performance (Including Connector) CLASS C(IEC 617;30) Max.Series Fuse Rating 15 A Connector T4 series or H4 UTX or MC4-EV02 I Application Classification Class A Per Pallet 30 pieces Power Tolerance 0-+5 W Per Container(40'HQ) 780 pieces *Under Standard Test Conditions(STC)of irradiance of 1000 W/m',spectrum AM 1.5 and cell temperature of 25°C. ELECTRICAL DATA I NMOT* TEMPERATURE CHARACTERISTICS CS1H 320MS 325MS! 330MS 335MS 340MS Specification Data Nominal Max.Power(Pmax) 236 W 240 W! 243 W 247 W 251 W Temperature Coefficient(Pmax) -0.37%/°C Opt.Operating Voltage(Vmp) 33.4 V 33.7 V 34.1 V 34.5 V 34.8 V Temperature Coefficient(Voc) -0.29%/°C Opt.Operating Current(Imp) 7.07 A 7.11 A 7.14 A 7.17 A 7.20 A Temperature Coefficient(Isc) 0.05%/°C Open Circuit Voltage(Voc) 41.0 V 41.1 V 41.2 V 41.3 V 41.5 V Nominal Module Operating Temperature 44±3°C Short Circuit Current(Isc) 7.60 A 7.63 A 7.66 A 7.70 A 7.73 A_ *Under Nominal Module Operating Temperature(NMOT),irradiance of 800 W/m'•spectrum AM 1.5,ambient temperature 20°C,wind speed 1 m/s. PARTNER SECTION I I The specifications and key features contained in this datasheet may deviate slightly from our actual products due to the on-going innovation and product enhancement.Canadian Solar Inc.reserves the right to make necessary adjustment to the information described herein at any time without further notice. Please be kindly advised that PV modules should be handled and installed by qualified people who have professional skills and please carefully read the safety and installation instructions before using our PV modules. .......................................................................................................... ................................................................................................................................................................................................................................................ CANADIAN SOLAR INC. I 545 Speedvale Avenue West,Guelph,Ontario N1 K 1 E6,Canada,www.canadiansolar.com,support@canadiansolar.com December 2019.All rights reserved,PV Module Product Datasheet V5.583 EN I I Single Phase Inverter with H- D-Wavelechnolo C gy m, for North America SE3000K-US j SE380OH-US / SE500OH-US J SE6000H'-US SE760OH-US / SE1 OOOOH-US / SE11400H.-US M 'C solar,�,�' ti.•�i�f.�rc ;I Optimized installation with HD-Wave technology / Specifically designed to work with / Extremely small power optimizers / Record-breaking efficiency / Built-in module-level monitoring / Fixed voltage inverter for longer strings / Outdoor and indoor installation / Integrated arc fault protection and rapid shutdown for / Optional: Revenue grade data,ANSI C12.20 NEC 2014 and 2017, per article 690.11 and 690.12 Class 0.5 (0.5%accuracy) / UL1741 SA certified,for CPUC Rule 21 grid compliance solaredge.com solar=@@ / Single Phase Inverter with H D-Wave Technology for North America SE3000H-US / SE380OH-US / SE5000H-US / SE6000H-US/ I SE760OH-US / SE10000H-US / SE1140OH-US OUTPUT Rated AC Power Output 3000 3800 @ 240V 5000 6000 @ 240V 7600 10000 11400 @ 240V VA 3300 @ 208V 5000 @ 208V 10000 @ 208V Maximum AC Power Output 3000 3800 @ 240V 5000 6000 @ 240V 7600 10000 11400 @ 240V VA 3300 @ 268V 5000 @ 208V 10000 @ 208V AC Output Voltage Min.-Nom.-Max. ✓ ✓ ; ✓ ✓ ✓ ✓ ✓ (211-240-264) Vac AC Output Voltage Min.-Nom.-Max. ✓ ✓ ✓ Vac (183-208-229) AC Frequency(Nominal) j 59.3-60-6051 Hz Maximum Continuous Output i Current @240V 12.5 16 f 21 25 32 42 47.5 A Maximum Continuous Output _ Current @208V 16 24 48.5 A GFDI Threshold 1 A Utility Monitoring,Islanding Protection, Yes Country Configurable Thresholds INPUT Maximum DC Power @240V 4650 5900{ 7750 9300 11800 15500 17650 W Maximum DC Power @208V - 5100 j 7750 15500 W Transformer-less,Ungrounded Yes Maximum Input Voltage i 480 Vdc Nominal DC Input Voltage j 380 400 Vdc Maximum Input Current @240V91 8.5 10.5 1 13.5 16.5 20 27 30.5 Adc Maximum Input Current @208VR) 9 13.5 27 Adc Max.Input Short Circuit Current 45 Adc Reverse-Polarity Protection Yes Ground-Fault Isolation Detection 600ksr Sensitivity Maximum Inverter Efficiency 99 99.2 % CEC Weighted Efficiency j 99 99 @ 240V % 1 98.5 @ 208V Nighttime Power Consumption j <2.5 I W ADDITIONAL FEATURES j Supported Communication Interfaces RS485,Ethernet,ZigBee(optional),Cellular(optional) Revenue Grade Data,ANSI C1220 Optional(" Rapid Shutdown-NEC 2014 and Automatic Rapid Shutdown upon AC Grid Disconnect 2017 690.12 STANDARD COMPLIANCE Safety ,UL1741,UL1741 SA,UL1699B,CSA C22.2,Canadian AFCI according to T.I.L.M-07 Grid Connection Standards IEEE1547,Rule 21,Rule 14(HI) Emissions FCC Part 15 Class B INSTALLATION SPECIFICATIONS AC Output Conduit Size/AWG Range I"Maximum/14-6 AWG 1'Maximum/14-4 AWG DC Input Conduit Size/#of Strings/AWG Range ;1"Maximum/1-2 strings/14-6 AWG 1"Maximum/1-3 strings/14-6 AWG Dimensions with Safety Switch 17.7 x 14.6 x 6.8 /450 x 370 x 174 21.3 x 14.6 x 7.3/540 x 370 x 185 In/ (HxWxD) mm Weight with Safety Switch 22110 25.1/11.4 1 26.2/11.9 38.8/17.6 lb/kg Noise <25 <50 dBA Cooling Natural Convection Operating Temperature Range -13 to+140/-25 to+60t4l(-40'F/-40'C option)(=) `F/-C Protection Rating NEMA 4X(Inverter with Safety Switch) 'For other regional settings please contact SolarEdge support �A higher current source may be used;the inverter will limit its input current to the values stated �Revenue grade inverter P/N:SEx H-USOOONNC2 For power de-rating information refer to:https,//v .solaredge.com/sites/default/files/se-temperature-derating-note-na.pdf s-40 version P/N:SEocxxH-US000NNU4 2.SolarEdge Technologies,Inc.All rights reserved.SOLAREDGE the S01arEdge logo,OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies,Inc.All ® other trademarks mentioned herein are trademarks of their respective owners.Date:03/2019N Ill®H01/ENG NAM.Subject to change without notice. S I