HomeMy WebLinkAbout20-1060 fit fl
City Of Z@phyrhlllS PERMIT NUMBER
r,
5335 Eighth Street
Zephyrhills, FL 33542 BNR-001060-2020
Phone: (813)780-0020
,`' •� `` Fax: (813)780-0021
Issue Date: 12/04/2020
Permit Type: Building New (Residential)
Prope„�rtyyNumber � �;�° _ Street Address•
/ 32 25 21 0040 01300 0110 35835 Iron Redding Court
Owner Information PTermit Information Crontractor Information
Name: D R HORTON Permit Type:Building New(Residential) Contractor: D R HORTON INC
Class of Work:SFR Construct
Address: 12602 Telecom Dr Building Valuation:$130,000.00
TAMPA,FL 33637 Electrical Valuation:$7,000.00
Phone: (813)549-1968 Mechanical Valuation:$4,500.00
Plumbing Valuation:$7,200.00
Total Valuation:$148,700.00
Total Fees:$18,556.00
Amount Paid:$18,556.00
Date Paid:12/4/2020 1:17:54PM
Project Description
CONSTRUCT SINGLE FAMILY 2,755 SQ FT-SILVERADO
Application gees '
School Impact Fee $8,328.00 Mechanical Permit Fee $62.50
Transportation Impact Fee $3,595.68 Public Safety Impact Fee-Admin $26.35
Mechanical Plan Review Fee $31.25 Plumbing Permit Fee $76.00
Electrical Plan Review Fee $37.50 Plumbing Plan Review Fee $38.00
Park Impact Fee-Single Family/Townhome $769.56 Sewer Connection Residential Fee $2,090.00
Building Permit Fee $680.00 3/4 Water Meter Fee(Galt) $473.78
Driveway Fee $45.00 Irrigation 3/4 Meter(Cale) $473.78
Building Plan Review Fee $340.00 SIF 1 percent Fee $83.28
Address Fee $30.00 Electrical Permit Fee $75.00
Transportation Impact Fee-City $36.32 Water Connection Residential Fee $1,010.00
Public Safety Impact Fee-Police $254.00
REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c)the
local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or
first reinspection,whichever is greater,for each subsequent reinspection.
Notice: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that
may be found in the public records of this county, and there may be additional permit required from other governmental
entities such as water management, state agencies or federal agencies.
"Warning to owner:Your failure to record a notice of commencement may result in your paying twice for
improvements to your property. If you intend to obtain financing,consult with your lender or an attorney
before recording your notice of commencement."
Complete Plans,Specifications add fee Must Accompany Application.All work shall be performed in
accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O.
NO OCCUPANCY BEFORE C.O.
CONTRACTOR SIGNATURE PE IT OFFICE
PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION
CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED
PROTECT CARD FROM WEATHER
~'~-1""_%J"4v City of ZenhY[hiU8 Permit Application Fa»813-780-0021
Building Department
Date Re�eived com
Phone Contact for Permitting
Owner's Name C= Owner Phone Number
Owner'sAddressl 17_(,0o-?_,-_.Tdecom'Dy- Ma 3�L Owner Phone Number
Tee Simple Titleholder Name f\4LJZ_ Owner Phone Number
Fee Simple Titleholder Address
JOB ADDRESS 5S15-Z31;- MlKmi U C-6 zqok g k;11:3, R 3.-L" LOT# 11/k3
ouomwmKON F El 1k, xRcELuD#
(OB'.MiE"FROM PROPERTY TAX NOTICE)
WORK PROPOSED wewcomsrn F7 aDO/ALT F---1 a|GN �--� [--� DEMOLISH
INSTALL [ � REPAIR
PROPOSED USE �--� ' aFR �-1 COMM F---1 oTHER
TYPE OF CONSTRUCTION ' BLOCK �—1 FRAME �--1 STEEL
BUILDING SIZE SQ FOOTAGE 4r-t HEIGHT
F--�8U|LD|N�
�—� VALUATION OF TOTAL CONSTRUCTION
=ELECTR[AL AMP SERVICE �--� PROGRESS ENERGY �—1 VY.R.E.C.$ 2-4 0L]=pLUMs(NG
=MEOH8N)CAL $ VALUATION OF MECHANICAL INSTALLATION
~~.~ V7 � =' ��/�
/
=GAG EY RoOF\No F—l � SPECIALTY �--� OTHER
FINISHED FLOOR ELEVATIONS 07FLOOD ZONE AREA =YE8 NO
BV/LDER COMPANY
SIGNATURE nso/STEneo FEft CUnRsI�
Address Lioynso#
ELECTRICIAN COMPANY .
SIGNATURE nsoIcnsnso ` pEEE�o6nwcN
Address ibblog ph. Lioonsa#
PLUMBER
Ilk-
SIGNATURE
Address
MECHANICAL COMPANY
SIGNATURE FEE CURREN
Address Liconso#
OTHER COMPANY
SIGNATURE neo/��nso
FEE CURREN ____'
Address NAU PA 6&u License#
xxxxx � mmxxnuxxuwmnunuxn 'mxunu �� xmumxxxuxmx � mxxxuxmm � uxxxxxDNVxoxnxxm
RESIDENTIAL Attach U4 Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction,
Minimum ten(1O)working days after submittal date. Required una\te.Cunotruo§on Plans,GUonnwmter Plans vl Silt Fence installed,
Sanitary Facilities&I dumpster;Site Work Permit for subdivisions/large projects
COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit forniew construction.
Minimum ten(1O)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Pence installed,
Sanitary Facilifies&1 dumoster.Site Work Permit for all new projects.All commercial require m* ents must meet compliance
SIGN PERMIT Attaoh(2)sets oY Engineered Pliaoo.
**°^PROPERTY SURVEY required for all NEW construction. '
Flit out application completely.
Owner&Contractor sign back of application,notarized
If over$osuu^a Notice pf Commencement|srequired. (VC upgrades over*75VV)
Agent(for the contractor)or Power of Attorne�(for the owner)would be someone with notarized letter from owner authorizingsame
OVER THE COUNTER PERMITTING (copy of contract required)
Remofsifshingles So*aro Service Upgrades A/C Fonoen(P|nVGumey/Footage') `
Driveways-Not over Counter ifon public modvayo..nuednROW
. ^^ �
� \
� \ '
NOTICE CJF DEED RESTRICTIONS: The undersigned understands thai this permit may ba subject tn "dead" restrictions" .
which may ba more restrictive than County regulations, The undersigned assumes responsibility for compliance with any
applicable deed restrictions.
UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has h\reda -contrector or
contractors to undertake
vvnrk` they may be required to be licensed in accordance with state and local regulations. If the
contractor is not licensed as.required by |avv, both the owner and contractor n7�ay be cited for m misdemeanor violation
under state |ovv. If the owner or intended contractor one uncertain as to what licensing requirements may apply for the
intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing-Section at 727-847-
8009, Furthermore, if the owner has hired a contractor or contractors, he is advised to have thb contractor(s) sign
portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as,the
ountroctor, that may be an indication that he is notproper|y]iconsed and is not entitled to permitting privileges in Pasco
County.
TRANSPORTATION lD8PACT/UTlL|T|ES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands
that Tnanaporbadon )nnpaotFees and Recourse Recovery Fees may apply to the oonsbucUonnf new buildings, change of
use in existing bu||d|ngm, or expansion of existing bui|dingu, as specified in Pasco County Ordinance number 88'07 and
QO-O7. oaamended. The undersigned also understands, that such fees, as may be due, will be identified at the time of
permitting. It in further understood that Transportation Impact Foee'ond Resource Recovery Fees must be paid prior to
receiving o "certificate of occupancy" or final power release. If the project dome not involve n certificate of occupancy or
final power.release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact
fees are due,they must�be paid prior to permit issuance in accordance with applicable Pasco County ordinances.
CONSTRUCTION L|EN LAW (Chapter 713, Florida Statutes, aemomoodod): If valuation of work|n$2.5D0.O8or more, |
certify that i, the app|\uant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's
Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone
other than the"owner", I certify that I have obtained a copy of the above described document and promise in good faith to
deliver itto the"mvvna/' prior tocommencement.
CO0TRACT0R'SVOVVNER'S AFFIDAVIT: i certify that all the information in this application in accurate and that all work
will ba done in compliance with all applicable |ovva regulating construction, zoning and land development. Application is
hereby made to obtain a permit to do work and installation an indicated, ! certify that no work or installation has
oornrnanoed prior to issuance of permit and that all work will be performed to meet standards of ail \avva regulating
construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. | also
certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is
my responsibility to identify what actions I must take to be in compliance, Such agencies include but are not limited to:
- Department ufEnvironmental Protection-Cypress 8oyhaads` Wetland Areas and Environmentally Sensitive
Lands,Water/Wastewater Treatment.
' Southwest Florida Water Management District-Wells', Cypress Beyheada, Wetland Areas, /Uhsdng
VVatencnuneao.
- /\rOny Corps ofEngineere'Geavva||a. Doohg' Navigable Waterways.
- Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment,
Septic Tanks.
- UG Environmental Protection Agency-Asbestos abatement.
- Federal Aviation Authodty'RuDvvayo.
| understand that the following restrictions apply to the use of fill:
- Use of fill |a not allowed \n Flood Zone"V'un|ena expressly permitted.
- If the fill material is to be used in Flood Zone 'A', it is understood that a drainage plan addressing a
"compensating vol.Vrne" will be submitted at time of permitting which is prepared by a professional engineer
licensed by-the State OfFlorida.
- If the fill,material is to be used in Flood Zone 'YY' in connection with o permitted building using otmrO vv8\|
construction, I certify that fill will be used only to fill the area within the stem wall.
- If fill material is to be used in any area, I certify that use of such f||| will not adversely affect adjacent
properties. If use of fill is found to adversely affect adjacent properties, the'owner may be cited for violating
the conditions of the building permit issued under the attached permit application, for lots |eee than one /1\
acre which are elevated by fill, an engineered drainage plan isrequired.
If\ am the AGENT FOR THE OWNER, i promise in good faith to inform the owner of the permitting conditions set forth in
this affidavit prior to commencing construction. | understand that a separate permit may be required for electrical work,
p|u[Db|ng, signs, vvaUa' po0|s, air conditioning, gas, or other installations not specifically included in the application. A
permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or
set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter
requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid
un|000 the work authorized by such permit is :o[nnOeDood within six months Of permit issuance, or if work authorized by
the permit is suspended or abandoned for a period of six(6) months after the time' the work is commenced. An extension
may be requested, in Vvriting, from the Building Official for a period not to exceed ninety (AO) days and will demonstrate
justifiable cause for the extension. If work ceases for ninety(90)consecutive days, the job is considered abandoned.
.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF C(380K8ENCE. ENT K8AY RESULT IN YOUR
PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT
WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
- ' __- --_'--__-----_--�-___
oWncRomAo � CONTRACTOR
Subscribed and sworn to(or afflm)Ndg)bef 9 this Subscribed and sworn to(or afflrmed)before me this
Who islare p or has/have prodtraed star-e personally knov�n to me or has/have produced
as identification. as identification.
=�~ otaryPub|io
/ cr
Commission No. Commission No.
'
s PASCO COUNTY,-FLORIDA
Permit No.
p Date Permitted
'Builder Name/Owner Neme D F— Control#'
County Parcel No. 3 2-..Zc_Z_1 f�6 O 1,3tb 0//,0 SubDIv. �S f ItJe
Address/Location c � 3S CZ —ClYi
ClissiticationlType of Usk r
TRANSPORTAT-ION,IMPACT FEE . Rate: Sq.Ft Unit:
Exempt L]Yes [].No How Determined
ImpdcrFee Amount $,3l 43 2 Zone No. TAZ:
SCHOOL'IMPACTFEE_.,
Account ' ( e), SlriWe=Family petached House Amount $
i '(057) Mobile'Home
(055) Other Residential
423)• Collection Fee
` Exempt [ Yet..Q No How Determined
PARKS`ANtl-RECWTION'fEE-
L.and-Abcount Land Credit • Land Total
Recreation Account Recreation Credit Recreation Total
Zone _ TOTAL AMOUNT $ '2 6
Exempt Q Yes []No How Determined
LIB,RW FEE
Lan0.Account Land-Credit Land Total
Facility Account Facility Credit Facility Total
Exempt ❑Yes ❑No How Determined Total Amount
RESOURCE FEE ERU
TOTALAMOUNT
Prepared By -; Checked By
NO CERTIFICAT-0 OF;OCCUPANCY WILL BE ISSUED.OR FINAL INSPECTION
PERFORMED.UNTIL THE TOTAL:AMCLlNTS LISTED HAVE
BEEN'PAID AND
RECEIPTED FOR SY A CENTRAL PERMLT A 00ACE.OF PASCO COUNTY
Ackitowledgement.below does hot Imply acceptance of concurrence,but simply racelpt of.p copq..of this form,placing
the;diultdtng pahalt owner on notice of this assessment Md-tho conditions of payment for same.
DATE RECEIVED BY
RECEIPT NO. DATE BY
D
Q'
ti
i
Single Family Dwelling
Plan Review Comments
1. F.F.E.. shall be a minim6m of 8"above the road elevation and an engineered site plan.
2. Lots shall be- graded to.comply with-R401.3.of the.F.B.C.
3. Compaction test required if 24".or more of fill dirt is brought in at any one place.
4. Tie in survey required before pouring concrete.
.5. Driveways require.a R.O.W. use_ perm_it: All 4 sides_ of driveway thru the sidewalk shall have
expansion material.
6. All setbacks shall be met.
7. All property markers shall be uncovered and marked at time of first inspection.
8: All AD.A.requirerrients shall be met:
9. No electric, plumbing, mechanical, or.framing shall be:covered without an inspection and
approval first.
10. All.Garages shall comply with section R302.6 of the F.B.C. (Fire Separation).
1 I.. Appliances shall not be installed in a location where subject to mechanical damage unless
protected by approved barriers. M303.4 of the F.B.0
12. Water heaters shall comply with section P607.3 of the F.B.C.
13.-Foundation supports for A/C units shall b:e-raised at least 3" above finished grade. M1308.1
14, Return air in all bedrooms. F.B.C. M1620.4
1-5. Smoke detectors are to be installed in accordance with R3111 of the.F.B.C.
16.-All glazing requirenients are to b.e in accordance with R308.4 of the F.B.C:
17. All means of egress are to be in accordance with R311 of the F.B.C.
18. `-`Green gypsum board"shall not be used as a backer in showers or tubs. R702A.2 F.B.C.
19:.Combinatiori-type AFCI breakers are required at all locations requiring an AFCI type breaker.
20. Carbon monoxide alarms will be required in' new construction that uses fossil-burning heating or-appliances or an attached garage. They shall be installed in accordance with the F.B.C:
21. All plumbing, mechanical, and electrical shall'be separate.from unit to unit: This includes all
underground plumbing and electric.
22. All 2016 N.E.C. Codes will be enforced.
1
t:
23: Tamper- Resistant Receptacles in accordance with 406.11 of the 2016 N.E.0
24. Iri accordance with the Land Development'Code,lots..shall be sod_ ded before fuial at least 10
feet around the structure.
25-. R403.5.3Hot.water,pipe insulation
Insulation for hot_Water pipe with'a minimum thermal resistance (R-value) of R-3 shall be applied to the
following:
Piping.31.inch (19.1 mm)and larger in.nominal diameter..
Piping,serving more than one dwelling unit.
Piping located outside the conditioned space:.
Piping'from the.water heater to a distribution manifold:, .
Piping.located under.a floor slab.
Buried in piping.
Supply and retum piping in recirculation systems other than demand recirculation systems.
25:Blower,door test shall be provided:before C,O:
26.A copy of the-enerky cacls shall be with permit at all times
27.. Copu of rnal:insulation report shall be provided with Permit before FnaL
28. No fence, pool or'scre-en enclosure :is issued with:this.permit
F.F.E.-Finished Floor Elevation
F.B.C-Florida Building Code 6t'Edition
R.O.W.-Right of Way.
A.D.A.-.Americans with Disabilities Act. N.E.C:-National Electric Code (2016)
PLOT PLAN
DESCRIPTION:(AS FURNISHED)
LOT 11, BLOCK 13, SILVERADO RANCH SUBDIVISION PHASE 10A
AS RECORDED IN PLAT BOOK 80, PAGE(S) 107-112, OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA.
ON LOT CALCULATIONS
LOT = 7.849 SO. FT.
LIVING AREA = 2,045 SQ. FT.
GARAGE = 454 SQ. FT.
ENTRY = 35 SQ. FT.
PATIO
DRIVEWAY = 404 SQ. FT. \ \ �� jORi�q"'t q q a
129.2
A/C PAD - 12 SQ. FT. CF qR
WALKWAY = 45 SQ. FT.
IMPERVIOUS = 41%
= 3216 SQ. FT. m'
SOD = 4,633 SQ. FT.
OFF LOT CALCULATIONS i
RIGHT OF WAY = 1169 SQ. FT. Z
DRIVE APRON = 60 SQ. FT. GRAPH 1' = 3S0�'p�'
PUBLIC S/W = 359 SQ. FT. BIC / \
SOD = 750 SQ. FT. 0 15 30
AREALS 9,018 SQ. FT. ���� �/ �
DRIVEWAY = 464 SQ. FT.
SIDEWALK 404 SO. FT. a � �T
`� / ( +60
SOD = 5.383 SQ. FT. v0
� /
0 / �U e�0+s SCE J 1
12B•5
/• yam. N��O�)�
127.4
�'�� // • '`�a „'�'; -:.a @7•
A,
PC / 126.76
s /
N
FOR/ RFOp � �9• Line Table
r(y/��gQl.0 7lt Une f Direction Length
Off,CYr F. CO 4s•
PREPARED FOR: �qR/ J�q �/ip� R�\ L2 S67'SZ32•E 23.95'
D'11'HOR1[ N-� � (k kF�� L3 S58'15'24'E 31.08'
�SG'NlCGi'S�ldF6G2'�16 �14Y
PI
Curve Table
BUILDING SETBACKS Curve I Length Radlue Delta Chord Bearing Chard
FRONT: 22' C1 28.73' 192.00' B34'26' NBB'13'05-W 1 28.70'
REAR: 13'
SIDE: 5' (50' LOTS) C2 43.23' 55.00' 45-01'50' N6959'23'W 42.12'
7.5' (55' k 60' WIDTH LOTS)
SIDE STREET: 15'
NOTES:
1. ELEVATIONS SHOWN ARE PER LOT GRADING
PLANS PROVIDED BY THE CLIENT. LEGEND:
2. ELEVATIONS ARE BASED ON NAVD 1988
DATUM. — •—•— BUILDING SETBACK UNE PI POINT OF INTERSECTION
3. FOR ALL LOTS WHERE SIDE—YARD —— — CENTERLINE PPC POINT OF T POINT OF CURVATURE
SETBACKS ARE LESS THAN 7.50 FEET, ATANGENCY
MINIMUM 5.00 FOOT WIDE DRAINAGE AND —--— RIGHT OF WAY LINE RP RADIUS POINT
ACCESS EASEMENT IS REQUIRED PER PASCO XX.XX PROPOSED ELEVATION PRC PONTF REVERSE CURVATURE
PCC POINT NT OF COMPOUND CURVATURE
COUNTY LAND DEVELOPMENT CODE. PROPOSED DRAINAGE FLOW TYP CS TYPICAL CONCRETE SLAB
THIS PLOT PLAN IS INTENDED FOR PERMITTING PURPOSES ;;. CONCRETE �P) OALCULLAATED
ONLY. THIS IS NOT INTENDED FOR THE CONSTRUCTION OF (C PLAT BOOK
THE PROPOSED HOUSE REFER TO HOUSE PLAN AND A/C AIR CONDITIONER PB PGS PAGES
OPTION LIST FOR CONSTRUCTION. ALL BUILDING SET BACK S/W SIDEWALK SO. FT. SQUARE FEET
LINES SHOWN HEREON IS PER DATA FURNISHED BY CLIENT F.E.M.A. FEDERAL EMERGENCY MANAGEMENT AGENCY
AND IS FOR INFORMATIONAL PURPOSES ONLY. F.I.R.M. FLOOD INSURANCE RATE MAP
NAVD NORTH AMERICAN VERTICAL DATUM
THIS IS NOT A SURVEY NGVD NATIONAL GEODETIC VERTICAL DATUM
D&UE DRAINAGE&UTIUTY EASEMENT
POE PRIVATE DRAINAGE THIS IS A PLOT PLAN ONLY PUE PUBLIC UTILITY EASEMENTENT
FLOOD NOTE: SURVEYOR NOTES:
I HAVE EXAMINED THE F.I.R.M. MAP NO. 12101CO28BF, 1. THE SURVEYOR HAS NOT ABSTRACTED THE
DATED SEPTEMBER 26, 2014. AND FOUND THE SUBJECT PROPERTY LAND SHOWN HEREON FOR EASEMENTS, RIGHT
APPEARS TO LIE IN ZONE-X', AREAS DETERMINED TO BE OUTSIDE THE OF WAY, RESTRICTIONS OF RECORD WHICH
0,211 ANNUAL CHANCE FLOODPLAN. THE SURVEYOR MAKES NO MAY AFFECT THE TITLE OR USE OF THE LAND.
GUARANTEES AS TO THE ABOVE INFORMATION. PLEASE CONTACT THE
LOCAL F.E.M.A. AGENT FOR VERIFICATION. 2. NO UNDERGROUND IMPROVEMENTS HAVE BEEN
BEARING BASIS: LOCATED EXCEPT AS SHOWN.
A!5hA
BEARINGS SHOWN HEREON ARE BASED ON THE CENTERUNE OF IRON 3. NOT VALID WITHOUT THE AUTHENTIC
REDDING COURT BEING N58o4'04'W,PER PUT. ELECTRONIC SIGNATURE AND THE AUTHENTIC
A M E FZ I CA N ELECTRONIC SEAL OF A FLORIDA LICENSED
(FIELD DATE:) REVISED: SURVEYOR AND MAPPER.
SU F2�/IE=Y I N G Digitally signed bylames W
SCALE: 1' 30 FEET
DN BolerUS,st=Florida,l=0dando,
8cMAPPING --1RI-N SURVEYING&
APPROVED BY: jajam• r_MAPPING,Mr.cn=i—W
CERTIFICATION OF AUTHORIZATION NUMBER LBa6393 k '.m a Boieman. FOR
200647 LOT 11, 3191 MAGUIRE BOULEVARD, SUITE 200
...;;. email=jboleman@asmcorporate.co FIRM
JOB NO. BLOCK 13 ORLANDO, FLORIDA 32803 ,, `""'°' ,• m FIRM
PLOT PLAN 2 08 11 2020 JG (407) 426-7979 n.m�mnna sa tcmmn man
DRAWN BY: DSB PLOT PLAN 08-29-20 SO WWW.AMERICANSURVEYINGANDMAPPING.COM JAMES W. BOLEMAN PSM 6485 DATE
20 J