Loading...
HomeMy WebLinkAbout20-1068 I O ' A City Ze of h p Yrhills PERMIT NUM EB R 5335 Eighth Street Zephyrhills, FL 33542 BNR-001068-2020 { Phone: (813)780-0020 Fax: (813)780-0021 Issue Date: 12/17/2020 >_ Permit Type: Building New (Residential) Pro a Number 'I _ ,�,„ap,arty _ � - ..,;._ Street Address 32 25 210040 01300 0120 135821 Iron Redding Court Owner Information &: P,rrmitlnfocmation Contractor Information Name: D R HORTON Permit Type:Building New(Residential) Contractor: D R HORTON INC Class of Work:SFR Construct Address: 12602 Telecom Dr Building Valuation:$160,000.00 TAMPA,FL 33637 Electrical Valuation:$8,200.00 Phone: (813)549-1968 Mechanical Valuation:$6,000.00 Plumbing Valuation:$9,500.00 Total Valuation:$183,700.00 Total Fees:$14,770.94 70. —„ Amount Paid:$14,770.94 /��f Date Paid:12/17/2020 1:05:13PM P oject Description CONSTRUCT SINGLE FAMILY 3,713 SQ FT-SILVERADO ! P. plicafiion Fees Address Fee $30.00 Electrical Permit Fee $81.00 School Impact Fee $8,328.00 Building Plan Review Fee $415.00 Mechanical Permit Fee $70.00 Driveway Fee $45.00 Plumbing Permit Fee $87.50 Plumbing Plan Review Fee $43.75 Transportation Impact Fee-City $36.32 Building Permit Fee $830.00 Transportation Impact Fee $3,595.68 Mechanical Plan Review Fee $35.00 Public Safety Impact Fee-Police $254.00 Park Impact Fee-Single Familyfrownhome $769.56 Electrical Plan Review Fee $40.50 Public Safety Impact Fee-Admin $26.35 SIF 1 percent Fee $83.28 REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each subsequent reinspection. Notice: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permit required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner:Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications add fee Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. CONTRACTOR SIGNATURE PE IT OFFICE PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER ~'~-'""_u"4" City of Zephyrhills Permit Application Fa»8 3-78O-0021 Bull8ing Department . . Phone Contact for Permitting I I I-1-V IF_L 11—1 _IL a I a I I I A 71 1 1 1 A A A a a I A ! I a 1 -.1 A—A. Owner's Name ' �6 c�m �n c Owner Phone Number "Fee Simple Titleholder Name Own'er Phone Number Fee Simple Titleholder Address BUILDING SIZE SQ FOOTAGE HEIGHT JOB ADDRESS 7# LOT# (OBTAINED rROfA PROPERTY TAX NOTICE) WORK PROPOSED NEW CONSTR ADD/ALT SIGN DEMOLISH E5 INSTALL L__J REPAIR PROPOSED USE SFR COMM OTHER TYPE OF CONSTRUCTION BLOCK FRAME STEEL ' 5i . . a A a . . . . I I a �--iBU�D�G VALUATION OF TOTAL CONSTRUCTION �--�ELECTRCA� AMP �--1 PROGREGOEN2RGY �—� VKR�I. �_-� =PLUMBING =MECMANICAL MECHANICAL INSTALLATION =GA8 [—�� 'ROOFING SPECIALTY � l OTHER FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES NO BUILDER COMPANY ELECTRICIAN COMPANY C Address 16S 9two License# [EE 0 039-1 S_ P�U���� �o�7xNY SIGNATUREnsa/ar�nso L_��_�_� r�ecunn�^ L_l��L_| `~ Address License# MECHANICAL SIGNATURE L —1 ` L��LNI_ pseounnEN [LLLN_J Address D License# OTHER cuMpxmr SIGNATURE nso/arsnso L_l/_N_J rEEoum~E^ LYIN_J~' Address License# RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(1O)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans wl Silt Fence installed, Sanitary Facilities&I dumpster;Site Work Permit for subdivisions/large projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page-,(1)set of Energy Forms.R-O-W Permit for new construction. Minimum ten(1U)working days after submittal date. Required onx)te.Construction Plans,Gtormvwatnr Plans v/Silt Fence installed, Sanitary Facilities&1 dumoster.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(z)sets of Engineered Plans. °~**PROPERTY SURVEY required for all NEW construction. ' Fill out application completely. Owner&Contractor sign back of application,notarized If over$2aoV^a Notice of Commencement isrequired. (Vo upgrades over$750V) � Agent(for the contractor)or Power ofAttorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy uf contract required) Romofsifshingles Sewers Service Upgrades A/C Fenouu(P|oVSumey/FootoQ6) ^ Driveways-Not over Counter ifon public madvmyo..needuROW ' NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to "deed" restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired' a contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as.required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing-Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly.licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACTIUTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Fees"and Resource Recovery Fees must be paid prior to receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or final power.release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due, they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW (Chapter 713, Florida Statutes, as amended): If valuation of work is $2,500.00 or more, I certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the"owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner" prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: - Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands, Water/Wastewater Treatment. - Southwest Florida Water Management District-Wells', Cypress Bayheads, Wetland Areas, Altering Watercourses. - Army Corps of Engineers-Seawalls, Docks, Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. - US Environmental Protection Agency-Asbestos abatement. - Federal Aviation Authority-Runways. I understand that the following restrictions-apply to the use of fill: - Use of fill is not allowed in Flood Zone"V" unless expressly permitted. - If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume" will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. - If the fill,material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction, I certify that fill will be used only to fill the area within the stem wall. - If fill material is to be used in any area, I certify that use of such fill will not adversely .affect adjacent properties. If use of fill is found to adversely affect adjacent properties, the'owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill, an engineered drainage plan is required. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior. to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six (6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety(90) consecutive days, the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. FLORIDA JURAT(F.S. 117.03) " OWNER OR AGENT CONTRACTOR Subscribed and sworn to(or affir d)before this Subscribed and sworn to(or affirmed)before me this bySI m by Who is/are personally known to me or has/have pro d Who is/are personally known to me or has/have produced as identification. as identification. _,4/P/Jljl��91K9-7 Notary Public Notary Public Commission No. Commission No. Name of Notary typed,printed or t 90Q AName of Notary typed,printed or stamped Pue� Not Public Sta4e of Florida " Michelle Moyes e a My Commission GG 057321 or 7V EXPIM612121I2020 a PASCO COUNTY, FLORIDA Permit No. 1 ) Date Permitted //—!(>�20 Builder Name/Owner Name 1� Control#' ' County Parcel No. 32- 2�6 z t oo�O Q13t>b 0/2.Q SubDly. lye Address/Locatlon 367 82( •c�,,,,�_©_� hr�_ �-'a� ClassiflcatioruType•of Usg �� TRANSPORTATION IMPACT FEE . Rate: Sq.Ft Unit: 36,71' Exempt ❑Yes [ No ' How Determined Impact Fee Amount $, i (P 53A , Zone No. TAZ: K SCHOOL IMPACT FEE' = Account (058) Single-Family Detached House Amount $ (057) Nlabile'Home I (068) Other Residential 123)_ Collection Fee Exempt [ Yes..0 No How Determined PARK&AND'RECREATION FEE• Land Account Land Credit Land Total Recreation Account Recreation Credit Recreation Total Zane _4 TOTAL AMOUNT s'7� '; Exempt ❑Yes []No How DetermIned�' LIBRARmy.FEE Land Account Land-Credit Land Total Facility Account Facility Credit Facility Total Exempt ❑Yes ❑ No How Determined Total Amount t;) RESOURCE FEE — � ERU TOTALAMOUNT Prepared By ` C7 Checked By NO CERTIFICATEv.OF OCCUPANCY WILL8E,18SUED OR;t*IM, INSPECTION PERFORMED t1NTIL THE>TO'fAL AMOUNTS I:I$M HAVE 85E14 PIAID.AND. RECEIPTED.FOR BY A CENTRAL PERMITTING OFFICE•OF PASCO COUNTY AckiuxWedgementt!elow;tlaea not Unply acceptmce of acncutrenca;butalmpV recelpf ota copy;of this=form,placing the bulMm permit owwr on notice of the assessment and the conditions of payment far afte'. DATE RECEIVED'BY RECEIPT NO. DATE BY PLOT PLAN DESCRIPTION:(AS FURNISHED) LOT 12, BLOCK 13, SILVERADO RANCH SUBDIVISION PHASE 10A AS RECORDED IN PLAT BOOK 80. PAGE(S) 107-112, OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. ON LOT CALCULATIONS LOT = 8,887 SO. FT, LIVING AREA = 2,836 SO. FT. GARAGE = 619 SQ. FT. ENTRY = 65 so. FT. LANAI = 193 SO. FT. MULTI GEN = 25 SO. FT. DRIVEWAY = 825 SO. FT. A/C PAD - 12 SO. FT. WALKWAY = 0 SO. FT. 7�r?4CT IMPERVIOUS 4 f?C - 4575 SO. FT. SOD = 4,312 SO. FT. 0A cl %144 A4 - OFF LOT CALCULATIONS ?0 5,n p -0 RIGHT OF WAY = 1035 SQ. FT. IV 'IV DRIVE APRON = 264 SQ. FT, 1. 30 (a El PUBLIC S/W = 343 SO. FT. SCALE--, 6 . SOD = 428 SO. FT. 0 15 30 't, TOTALS AREA = 9,922 SO. FT. DRIVEWAY = 1,089 SO. Fr. SIDEWALK = 343 SO. Fr. SOD = 4.740 SO. FT. A,,.A) A) 0 ik fs! FO V d �,p ;0-0 ,lfj,%Q& IV fV *4 4% AD Cb P A, CV' 01 Al 7 c? Curve Table PREPARED FOR: Ile AIV Chard Bearing Chord 40pop `SSA Curve 0 Length Radius Delta --B--6 0-M-UN W"IT m/ I Cl 68.72! 192-00- 20W2W N73-40-38*W 68,36' BUILDING SETBACKS 0�1 "l FRONT 2. 0' ou L REAR: 1w SIDE* 5- (50- LOTS) 7.5- (55- & 60- WIDTH LOTS) SIDE STREET: 1W NOTES: 1. ELEVATIONS SHOWN ARE PER LOT GRADING PLANS PROVIDED BY THE CLIENT. LEGEND: 2. ELEVATIONS ARE BASED ON NAVD 1988 DATUM. BUILDING SETBACK LINE PI POINT OF INTERSECTION 3. FOR ALL LOTS WHERE SIDE—YARD PC POINT OF CURVATURE CENTERLINE PT POINT OF TANGENCY SETBACKS ARE LESS THAN 7.50 FEET, A RIGHT OF WAY LINE RP RADIUS POINT MINIMUM 5.00 FOOT WIDE DRAINAGE AND PRC POINT OF REVERSE CURVATURE PCP POINT OF COMPOUND CURVATURE PROPOSED ELEVATION ACCESS EASEMENT IS REQUIRED PER PASCO TYP TYPICAL COUNTY LAND DEVELOPMENT CODE. PROPOSED DRAINAGE FLOW CS CONCRETE SLAB �P) PER PLAT THIS PLOT PLAN IS INTENDED FOR PERMITTING PURPOSES CONCRETE C) CALCULATED ONLY. THIS IS NOT INTENDED FOR THE CONSTRUCTION OF THE PROPOSED HOUSE. REFER TO HOUSE PLAN AND A/C AIR CONDITIONER PGS PAGES OPTION LIST FOR CONSTRUCTION. ALL BUILDING SET BACK S/w SIDEWALK SO. FT. SQUARE FEET LINES SHOWN HEREON IS PER DATA FURNISHED BY CLIENT F.E.M.A* FEDERAL EMERGENCY MANAGEMENT AGENCY F.I.R.M. FLOOD INSURANCE RATE MAP AND IS FOR INFORMATIONAL PURPOSES ONLY. NAVD NORTH AMERICAN VERTICAL DATUM Nm NATIONAL GEODETIC VERTICAL DATUM THIS IS NOT A SURVEY D&UE DRAINAGE&UTILITY EASEMENT PRIVATE THIS IS A PLOT PLAN ONLY PDE PUE PUBLIC UTILITYDRAINAGE EASEMENEASEMENTT FLOOD NOTE: SURVEYOR NOTES- I HAVE EXAMINED THE F.I.R.M.MAP NO.12101C8288F. 1. THE SURVEYOR HAS NOT ABSTRACTED THE DAIEC SEPTEMBER 26, 2014, AND FOUND THE SUBJECT PROPERTY LAND SHOWN HEREON FOR EASEMENTS, RIGHT APPEARS TO UE IN ZONE*X". AREAS DETERMINED TO BE OUTSIDE THE OF WAY, RESTRICTIONS OF RECORD WHICH 0.2X ANNUAL CHANCE FLOODPLAIN.THE SURVEYOR MAKES NO MAY AFFECT THE TITLE OR USE OF THE LAND. GUARANTEES AS TO THE ABOVE INFORMATION,PLEASE CONTACT THE LOCAL F.LM.A. AGENT FOR VERIFICATION. 2. NO UNDERGROUND IMPROVEMENTS HAVE BEEN LOCATED EXCEPT AS SHOWN. BEARING BASIS: BEARINGS SHOWN HEREON ARE BASED ON THE CENTIERUNE OF IRON 3. NOT VAUD WITHOUT THE AUTHENTIC RMDING COURT BEING N58`O4!O4`W.PER PLAT. ELECTRONIC SIGNATURE AND THE AUTHENTIC ELECTRONIC SEAL OF A FLORIDA LICENSED (FIELD DATE:) REVISED: M F—== F:;,* I C,— SURVEYOR AND MAPPER. 4s U F:;,- I 4Z3 WlqUifysI9ndbyJa SW601— SCALE. 1*- 30 FEET DN:�USst-FlormdMdando, -& MAPPING INC. -AMERICAN SURVEYING&MAPPING, APPROVED BY: is INC.—jameswBoleman, CERTIFICATION OF AUTHORIZATION NUMBER LB#6393 a cmaIkqboIemaaL—wyPwatexcm FOR 200647 LOT 12, 3191 MAGUIRE BOULEVARD. SUITE 200 Dt.2020.07.0608,46-18-00W THE JOB NO. BLOCK 13 ORLANDO, FLORIDA 32803 FIRM (407) 426-7979 DRAWN BY: Osa 1 PLOT PLAN 06-29-2020 iso WWW.AMER[Ck'4,SURVEYINGANDMAPPING.COM JAMES W. BOLEMAN PSM# 6485 DATE PASCO COUNTY Receipt Date: 07/15/2021 DAS C -,. BUILDING CONSTRUCTION SERVICES Receipt Number: 2057618 8731 Citizens Drive COUNTY FLORIDA Suite 230 OPu.S1410E-S.VIrIu tx,'PLACES. New Port Richey, FL 34654 727-847-8126 ** NOT A PERMIT ** Paid By Check# CC Auth# Cashier ID Workstation Check 1324976 RRICHTER BCCCP53L Fee Description Amount Paid Impact Fee Residential Solid Waste Single Family 31.88 Total Payments: $31.88 Payor Address Phone DR Horton Comments: City of Zephyrhills-Solid Waste 35821 Iron Redding Ct 32-25-21-0040-01300-0120 While you will be paying your bill with Pasco County Building Construction Services,the full amount of the credit card ore-check fees,NOT shown above,is collected by First Billing payment services. myreports/reports//production/PASCO/Customer Receipt vlfrpt Print Date: 07/15/2021 Page 1 of 1 r`n an Cityof Ze h p Y rhills PERMITrNUMBER ..``` 5335 Eighth Street ; Zephyrhills, FL 33542 BGR-002368-2021 Phone: (813)780-0020 ` Fax: (813)780-0021 Issue Date: 06/24/2021 Permit Type: Building General (Residential) Property Number Street Address 32 25 210040 01300 0120 35821 Iron Redding Court Owner Information Permit Information Contractor Information Name: D R HORTON Permit Type:Building General(Residential) Contractor: LAWN MEDIC Class of work:Irrigation LANDSCAPING& IRRIGATION LLC Address: 12602 Telecom Dr Building Valuation: TAMPA,FL 33637 Electrical Valuation: Phone: (813)549-1968 Mechanical Valuation: Plumbing Valuation: Total Valuation:$0.00 Total Fees: n Amount Paid:d:$45.$45.00 l% Date Paid:6/29/2021 8:42:04AM Project Description. IRRIGATION CONNECT ONLY'*"'•' Application Fees Irrigation Connect Fee $45.00 REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each subsequent reinspection. Notice: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permit required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications add fee Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. O RACTOR SIGNATURE PE IT OFFICE PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER City of Zephyrhil(s Permit Application Building Department Date Received 40k a Phone contact for permitting CQ Owner Phone Number own e.Na.: Owner's Address F7- Owner Phone Number Fee Simple Intlehold rName Phone Ii Fee Simple Titleholdir Address JOB ADDRESS LoTip lU SUBDIVISION PARCELID01 52-�3- 94 QUO 0(3o-0 OFIC) (OSTAltrEDFROM PROPERTY TAX NOTICE) WORK PROPOSED I NEW CONSTRR ADDIALT SIGN DEMOLISH INSTALL REPAIR PROPOSED use SPR ryw-44 OT-r--, TYPE OF CONSTRUCTION 0 BLOCK Q FRAME Q STEEL i, DrSCRIPTION Of WORK BUILDINO SIZE SQ FOOTAGE HEIGHT . . . . . . . . . . . . . . . . . . I . . . . . . . . . . . . UILDING i. VALUATION OF TOTAL CONSTRUCTION =ELECTRICAL� AMP SERVICE Q PROGRESS ENERGY r7 W.R.E.C. &271KU—MBING =MECFIANICAL S VALUATION OF MECHANICAL INSTALLATION it =GAS = ROOFING Q SPECIALTY = OTHER FINISHED FLOOR ELEYA-11ONS FLOOD ZONE AREA =YES NO COMPANY SIGNATURE i REGISTERED I YIN FEE CURREN LYIN Address Llcense# ELECTRICIAN COMPANY SIGNATURE REGISTERED YIN FEE CURREN AddressI license# PLUMBER COMPANY Z FSIGNATURE hEbbIERED �OLESCURREN YIN Address Licenset: MECHANICAL COMPANY SIGNATURE REGIsrEREe YIN FEECURREN LxLN-J Address License V OTHER COMPANY SIGNATURE REGISTERED YIN FEE CURRENl Lj Address it License# RESIDENTIAL Anson,(2)Hot Flans', Sets Or 110cling Hans;(1)set or tnergy Forms;H-U-VV I-ermit for new construction, Minimum ten(10)working days after submittal date, Required onsite,Construction Plans,Stormwater Plans W Sift Fence Installed, Sanitary Facilities&t dumpster,Site Work Permit for subdivisionstlarge projects COMMERCIAL Aftach�(2)complete sets of Building Plans plus a Lie Safety Page;(1)wof Energy Forms,R-O-W Permit for now construction. Minimum ten(10)working days after submittal date. Required onsite,Constructon Plans,Stommater Plans wf Silt Fence Installed, Sanitary Facilities&I clumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance SION PERMIT Attach,,(2)sets of Engineered Plans. I PR�FPSRTY SURVEY required for ail NEW construction, Diro,64 16 MI!out 3poic-aticn,--Zmplem"'. 0.&Contractoritgn back of application,r.clarizea If over$2500,a Notice of Commencement Is required. (AIG upgrades over S7600) Agent(tor tlio conlru�ot)or Poftl OT Allorney(forlhe owner)Would be someone with notarized letter from owner authorizing some I OVER THE COUNTER PERMITTING (copy of contract required) Roroofs If shingles Bowers . Sorvico Upgrades A/C Fences(Plot/Suivey/Footage) GrIveways-Not over Counter if on public roadways-needs ROW NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to'deed"restrictions" vliliCil Illay 6C Alum:ICa6i6i1VV ii1a111.U61,11i mmwa,"110. 1116 ulrv610P6,mV OCOLrnW iGC�AgrOrvrO•➢fvi�.v �/uGIrW nnn o�� applicable deed;restrictions. UNLICENSED 'CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work,they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state raw If the owner or intended contactor are uncertain as to what licensing requirements may apply for the intended work,they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the"contractor B1ocK'of this application for which they will be responsible. If you,as the owner sign as the contractor,thavmay be an indication that he is not property licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPAC IIU I IL.11 it,IP1fYAU I ANU Kt,UUKI:t Kt1:UVtKT I-Ct6: I ne undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings,change of use in existing buildings,or expansion of existing buildings,as specified in Pasco County Ordinance number 89.07 and 90-07,as amended. The undersigned also understands,that such fees,as may be due,will be Identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a'certificate of occupancy"or final pourer release. If the project does not involve a certificate of occupancy or final power release,the fees must be paid prior to permit issuance. Furthermore,if Pasco County Water/Sewer Impact fees are due,they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION UEN LAW(Chapter 713,Florida Statutes,as amended): If valuation of work is$2,500.00 or more,I certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's Protection Guide'prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant Is someone ^thcr than thc';c,:ne ',I certiAl,that I have obtnired a cops of the above dcccribcd document and promiso In good faith to deliver it to the"owner"prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done incompliance with all applicable laws regulating construction,zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that i understand that the regulations of other government agencies may apply to the intended work,and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies Include but are not limited to: - Department of Environmental Protection-Cypress Bayheads,Wetland Areas and Environmentally Sensitive Lands Water/WastewaterTreatment. - Southwest Florida Water Management District-Welts, Cypress Bayheads, Wetland Areas, Altering Watercourses. - Army Corps of Engineers-SeawaIts,Docks,Navigable Watermays. - Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. - US'Environmental Protection Agency-Asbestos abatement. - Federal Aviation Authority-Runlorays_ I understand that the following restrictions apply to the use of fill: Use of fill Is not allowed In Flood Zone"V"unless expressly permitted. If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a .: c•li^..•,nl.rmc•"r.,ill ho cr,hmiHe.l al limo nF nermiHin^luhirh ie nrenararr by a nrnfac " =I anninaar Iiocnzad by the State of Floridia. - If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction,I certify that fill will be used only to fill the area-within the stem wall. - If(ill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of rill is found to adversely affect adjacent properties,the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one(1) acre which are elevated by rill,an engineered drainage plan Is required. If 1 am the AGENT FOR THE OWNER,I promise in good faith to Inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs,wells, pools, air conditioning, gas,or other installations not specifically included in the application. A _ -J..:aL aL- .-.1. .•col...a^ ..ai.�.J..a^ �Iwa.. col ..la^ Vellllll iaOUOV JtiO11 iic i.Viroiiucu iv uc c iiacnoc v�.----cu �.n•u• vv vr••ur ....•��� r •y . i �^�" ' �- set aside any provisions of the technical codes,nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans,construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit Issuance,or if work authorized by the permit is suspended or abandoned for a period of six(6)months after the time the work is commenced. An extension may be requested,in writing,from the Building Official for a period not to exceed ninety(90)days and will demonstrate Justifiable cause for the extension. If work ceases for ninety(90)consecutive days,the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOU NDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COM ENCE EN . OtNNER OR AGE r CONTRACTOR Subscribed ands r affirmed)before me tht5 p„� ;u 'bed an by or a. d)hefor�nn?this io 1sfare I so ally kno i to me or has/have produced VJ N o isl parse y to me orhaslhav�e produced as identi ioation. as identification. ----__ Notary Notary Public � 1 Commission No_' Commission No, �i"' I t r V a ' �yllb •r I, CfS�J1i4fi38tw� ,_ M�Cf� jj:�t5`#GG 925496 EXPIRES:February 23,2024 s, =" 'O' UndenvTiters a o: EXPIRES:February 23,2024 uUlic 'rFodv�?� Bonded Thru Notary P Bonded Thru Notary Public Underwriters 1, D Q r. t • Single Family Dwelling Plan Review Comments I. F RE; shall be a minimum of 8" above the road elevation and an engineered site plan. 2: Lots shall be graded to comply with R401.3 -of the F.B.C. 3. Compaction test required if 24"or more of fill.dirt is brought in at any one place. 4: Tie in survey required before pouring concrete. 5-. Driveways require a R.OV. use permit. All 4 sides of driveway thru the sidewalk shall have expansion material. 6: All setbacks shall be nret. 7. All property markers shall be uncovered,and marked at time:of first inspection. 8. All A.D.A.requirements shall be met: 9. No electric, plumbing;mechanical, or framing shall be covered without an inspection.and . .- - approval first: 10.. All Garages_shall comply with section R302:6 of the F.B:C. (Fire Separation): 11. Appliances shall not be installed in a location where subject to mechanical.damage unless protected by approved barriers. M303.4 of the RB:C 12. water heaters shall comply with section P607.3 of the F.B.C: 13. Foundation supports for A/C units shall be raised at least 3" above finished grade. M1308.:1 14. Return air in all bedrooms. F.B.C. M1620.4 15. Smoke detectors are to be installed in accordance with R313-.1 of the F.B.C. 16.All glazing requirements are to be.in accordance-With R308.4 of the F.B:C: 17. All means of egress are.to be in accordance'with R311 of the F.B.C. 18. "Green gypsum.board"shall not be used as a backer,in showers or tubs. R702.4.2 F.B.C. 19. Combination-type AFCI breakers are required at all locations requiring an AFCI_type breaker. 20. Carbon monoxide alarms will be required in new construction that uses fossil-burning heating or appliances or an attached garage. They shall be installed in accordance with the F.B.C. 21. All plumbing,mechanical; and electrical shall be separate from unit to unit. This includes all underground:plumbing and electric. 22. All 2016-N.E.C. Codes will be enforced. 4 23. Tamper- Resistant.Receptacles in accordance with 406.11 of the,2016 N.E.0 24. In accordance with the Land Development Code, lots_ shall be sodded before final at least 10 feet around the structure. 25. R403.5.3Hot water pipe insulation. Insulation for hot water. pipe with a minimum thermal resistance (R-value) of R-3 shall be applied to the following: Piping.1<inch (1.9.1 mm)and larger in nominal diameter. Piping,serving more than.one dwelling unit. Piping located outside the conditioned space: Piping from the water heater to a distribution manifold: _Piping.located under.a floor slab. Buried in-piping, Supply and return piping in recirculation systems other than demand recirculation systems. 25. Blower door test shall be provided before C.O: 26 A copy 6fthe en er y each shall be with permit at all times. 27. Copy offnal'insulation'report shall be provided ivith permit before rtnab 28. No fence, pool or screen enclosure .is issued with This permit. F.F.E:-Finished Floor Elevation F.B.C-Florida Building Code 6th Edition R.O.W.-Right of Way A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code (2016)