Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
20-1080
City of Zephyrhills PERMIT NUMBER 5335 Eighth Street Zephyrhills, FL 33542 ELCMISC-001080-2020 Phone: (813)780-0020 Issue Date: 12/07/2020 r' Fax: (813)780-0021 �f Permit Type: Electric Service Replacement/Misc Pr01—lI y Number Street Address 03 26 21 0120 00000 0580 6622 Foxmoor Drive Owner Information Permit Information Contractor Information Name: ALFRED CASTRO TASHA CASTRO Permit Type:Electric Service Replacement/M Contractor: SUNTUITY ELECTRIC LLC Class of Work:Add/Alter Residential Address: 6622 Foxmoor Dr Building Valuation:$0.00 ZEPHYRHILLS,FL 33542 Electrical Valuation:$40,950.00 Phone: (813)469-0776 Mechanical Valuation: , Plumbing Valuation: Total Valuation:$40,950.00 Total Fees:$367.13 [� Amount Paid.$367.13 Date Paid:12/7/2020 11:41:34AM V Project Description INSTALLATION ROOF MOUNT SOLAR PV PANELS Application Fees Electrical Permit Fee $244.75 Electrical Plan Review Fee $122.38 REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each subsequent reinspection. Notice: In addition to the requirements of this permit,there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permit required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner:Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing, consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications add fee Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. CON TOR SIGNATURE PE IT OFFICE PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER aw aaatai:aa scs � CRWROALFRM&SROTASHA I �ssFsae (8Y3� mod&. a��taAe�ms � t�i�[�1l�Li.sa�3�� Osm�f?Stasltas. - FeaSlzsplSF53r.'.e�dszlLtgt ... O�airP�aafhaaLer E.rSFsspGe iddTsas , ,1QSIla 6M F®XWCR bk ZEPHYMMS.FE 33542 w . s lrssaeN -C;Bv mails. IPtR 1iDs t i-Z&-2Y-0� fl .- .psiaastDTs�s�isrrTsize,4aiCi1 .-.. .. . rslot:ycPRnTOSJ3f U rcAU: . ::=® l�aDuls Q gm DW i REPM PROPOSEDUSE Cl : :SFR ET GOit1A ED OTHM s.... Z1fPEOFCONSTRICII[M p ': 81000 E3 FRAM: p STM_:p : OESCIU 1O1NOFt 3i ttQ;,btian of moo earef3tTTftd PV paTlds - 8alrcfD�resta�E sam FOLDINGFolstAsl: 11E1G1NT. -l"ALCONSUCCM QPL1l Cwm 7s . . ... - :7- : . . VARLKIIIO NOF.f tOf 17m vC7GA .. ®: SPE .A.L.T.Y CiOTHER S ROOFING . .' . FD15i$O1 t3EYAT1ON5 FLOOD ONEAREA � E Y NO Si>iLOER ANY FEtCUue----------------- . Addrssa Ucaroof.- :: AHY SU d)t ELea ,U.0 StGfNASU1tE TIN:' :RZCL MLtt 1G/ la Addnesa.. 2i3�R�� 35Tt Not "_ f:3cccrz�G PLUkfew : : :COMPANY .. ::SIGNATURE IF>7.rsTO11 D T►N R nvMeH YIN AddRss. .. . .. .- sicmTURE n[CaTzm TIN . :. rf!a mutem Y Addms UCense OTHER :: .:.: : - COt#PAN1f..: SIGNATURE aasTTeelo YIN fa:easMr�1 TIN Addnsa Eke" 1is gas 11111'111111111/Rig 1lflftliflttl�llif11.9912111i1111•1:111111121111:21 RESIDENTIAL. Attach(2)Pbt Piero.(2)sats d Brdldnl Plm:(1)set of EhM.Forms:R•O•W Permli for naw conirudloa, IAtidRnm lerl(10 orn4uFlon Plan,SlariTnraler Plans T�f S11 Fence Nntstled) 'days aM1er a�itirriSp date Requkad oilsla.C"" Saisry Fadit as a'1 duMp$W.SYe WO%PerwA foruhdbhbnsAaW eds .. ::COMMERCIAL Attach(I)mngllete fiats of I)WM Plans 0 s:a)Na STdety Pape(1)aN of Energy Farms.R-&W Peril for new CoiWJLCtWL . MGdnnm len(1Q)'worilnp.drlo eflarsr Mld"dal::Re�rirad•onslm, am Carts UL Plaia',SlampWerPisns wISO Fenn Ynt�od. ... Ssnllay FwA%m a 1 drmSnWl Saa We*Pam*for all new projects AI cernnerdel mqw march must moat=npw a SIGN PERINIT:: :Attach(2)sets of Enpa+oered Pidra ""'PROPERTY SURVEYro9�terau NEW corotc>rtllon-: .:. Oirsetloas: . Fil:ouf appllutlan mnipitley; owMra Gmtmcor alpn bade of eppI I tion;roadlad: .. . ... If ovii f�10,a Notka of Comnrenarnsnt Is nqulrsd(AfC uPlradas over fT!)00). Apart por the )or Poierer of Attbmey-poi tlid caner)v�ould w saneone velar natsdtad truer t+om orinei auliorlibip surm... OVER THE Comm PERMITTING. (cmof MgUV*M Reioots N etdr+ples Sewers::: : 9ervita Uftnades NC. Fences(PbVSurv*yiFoolape) Drlvirways-Nol over CouMerif on puMc roadrioys needs ROW + Fmc•a 13-7L2-0C�1 ar�.�tsx�zo City of Zeptyrltats f�errrstL AppGcattoa . tzceasteat>cm� Gdaeeaeaslatitffia�s .ctssza:C�Cas� �1.1=1 OLT- aa�rrsxa�c:e��a - �xs-sza;a..t�ses.c��ra � as�s�ss� --- �7 1rzsCac "kss rcdt �. �c �t Fx+:zC�r Ess•dr�3 r 6is*sue—a S zsmtTFT-K:-was. E+ssdaescca�Ctcs[r�P.asffifxffaa�amrersraac�s he sac°rFsedta�a�etts:sz ;s;s�s C�+"m`ss38is'"sE�crtlss . +t3sttic'3itte{it�7Cers'Cri>:L"re�ryGt s3E�¢�flCssQcffsA�Ls tn°r'�ytosssatrE�ctft�Reisffi[ i�uadunds rSOLenL"titd bt3cs0�7e�Fn PssmCcsa'.3g TRAHSPORTA=1d MPAt:SmnuTtw WPAOT AltD R£50URCE RECOVERY FEES.The IttzdeMk=d 0tW3tari1s ttsaZTiL afai6t t essaad tt�apE�s s t3Cmeoo sedaasD .drra rdaseb tw �d�rgt�sss�s�JbFstxoC�ETRrmeesats>�eatbsF+F6ds�5atlf.asamee:edTlsa�miatss . sa�sL4is�seaThedn~wrsrast�E'fei9�t�apseotpet�aty�[ia�s�ecatla[TrsoLr{�Faesi�dt'�tg.: Feasa�asDesa'slpiz��t eat4o�dao�q�ariesdpaaereslme iCeapa�e48eesses s cclad poieata�lesss aYtllSo�¢szEt Sbs3sibpems2 fbp%mmm. WPasaofCaa it* S15caat ar~sR4S�tb� 6Qpadtad� ae�a�raa���asamaoaa�e..�.r�r.at.a�tss2saafla=s[�[ce[rrta,.�et_es�- . . lW=bxn 9ai caccpgdaa'Rwida ties ;:PscteQaeC�ta ysrya[tr3ty>Artr Qesanmasd AasdGarsgeQAts RICaaFpieavt�smtarsalltateaafss toesLlytl�aitlrtoao9Ctatida ►eTiLaa .. �ord�iar�b�odb'1Ds�ct[osIDr't+�ta�pSortvmrt .. �lastr+tr t�tauasear�n��,+e�a�arz�s�xsa.a�ad.b,e� � att�eot:sanp�sa �saaaa�osec.Itppies�{t'stsess�r rsade b a6�is a�i>o lbw end its haoena loseyeve®.arcQsa,teaw �or[ot �apdasaatezte�ort.�ea �ie aaz tesracegat>drigemoft ran G_fftrardCPr_W=,a ksmajawk2m[ito oa:3y=l nade�asattasta.a�s>z� ss +sass�ytre�is .a�and e�satsm�imsa�ca�ai naattsbatnmzyLmoa 9ndsa<yeadest� buGsiwaaztm[adb,_, Dqwbnwd of Emtollroenial ftutertL�m s Bap earls,.WEftul.Areas and Emftmaa4aYy Se isifiee qL l arils,WT[easstteo3:. . : ... - Sa[tlmrest Flaslds W.W. O -VYtft. Qpess;Bayhea&, V61adaad.:was. .AReft Wakizourses. 9I1ai>?rrrsys. - .,. D of ti&mt Nl; Set+ a�lErs�ratazterttat HeatUt.th*-Wfells. Tma!r ant &!pftTaak& US Erzvhonirterttal PraMftn Agert4lAsbestas abatentenf Federal Avb t n Autltorily-Ritaways. tn+a�is�naemiasetaaostnpc�atazmis�eatiausaazta . - Use bf®Is clot a!leWed hf Badd Zane'lr Wenescptesralyi P It the ®materisal Is to be ttsed:in Flood Zone W.It Is understood that a drainage planaddiesskm a '=VensattttQ vnhmte wN be subndlted et:ttme .d permitiirtp Which ls:ptt�ared by a proiessrartal:enghtEer 6oertsed by the State of Florida.. .. .. It the®tttaterial Isla be tired hs Flood Zane A.in mrtriedlon with a permr�ted tiw3dm�tnarg sum wag tortstrucfiorl,I earthy that IM v a be used only to fill itis Brea ivChfra Ole stemvi.-a.: _ If�'m3lifW is.to be used 10:arty srea.'1 Certtfy tttal use of stigt'� VA [sol adversely attr add ptoperttes.it use of IM Is f iund to adversely erect adjacent pmped1w the at+[Iter may ke cited for vldaft ttte•martdltlarts of the bu➢ft pffm t!sued under the.attagied'ptimil appowttae%for lots teas Oran one.(1) acre w!aidz we eIrdaWd by fill,an engtrimmul drainage plan Is rerlttfrad. ulamttrei[tEtt>•FOR7lEtpNlttil:RtpRistsaiipooatattetalr�mtna.00aaerdthato�so�n.sezto�znsii:a[s<aa,tspeo.m . carQnad.�pmiatnsNoitlumfe amAmmasepardapffmameybamq+todford�fcalw4.p4a>�fnp d, .wela.pmts.alt dbut :rdaK nd pedC 01csdrrtbvowock6w azas :ealhorttybrlotaze.�l.al�r,orsiatosldreryprau6twsadtbetsdnldmdes.tasdutltrsuarsdapemipreres0r8�sQQadd6om zheseallerregstde+a.assrradasidaua�stnp[ans,mrstudaetarrdotatloiaarsrrycoda.EvaryDdmltas�dalwGbemmeiaisidaiessMwuprk. ... audbatadby such pamd1scmm lwazisid:mac adpaastlis>wr�eii.arYwakaidhytlnpes�alisaiapmdedor�as�adiasa period of a!s eaorr s aRer h t6m theworA Es airraenod M e>da+nton_mry zia !! ,to wdt>Ap rrom_CW B�irdtap 0ftW rar a period ft b, a d nbNY IQ days W4vA demaentr*}aliEahis�far ere ammsion Cwat toasts rnr nobly t90}mnaesat[re dens,the lob Is cansSdared xbandosbd. .. .... WARNING TO OWNER YOUR FAILURE TO RECORD.A NOTICE OF COMMENCEMENT MAY:RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY.IF YOU INTEND TO.Ot3TAIN FINANCING,C NSUL7 FLORIOA,tUi7AT(F QR 1311a: 1 CCNTMt: - subiab a Su or ed sro ems, II s t1i�alH Va r, :. .... s o isram pmwu ty kwm b me trhaaRttut pi0duad Who Brsro Wh penoisegy kr�ovm to me orhastl�nre pioduad on�n u. iclv!t a: .::: tdenitb[Nea Diary Pab0c ... Fab[c Canar�isabn Ho oa Ho.. mna err.S=rqmd REMwy arusra JORD. AN .D ENOYO , M JORDAN D MENOYO: ;�'. e-No Public-StateC�o! Florida �+ e'% i. � `t,�Notary Public-State of•Florida - Commission a G, 300899 - =� = s• -pot # GG 300899 My Commission Exp:ires,:: «•� - mission Ex Tres �� My Commission p February 12,2023 '%�q;;��•� "February 12, 2023 Suntuit FOWERTO CHANGEYOUR WORLD Y_ Suntuity Electric LLC 3030 Reynolds Rd, Ste 5 Lakeland,.FL 33803 Power of Attorney - Permit Authorization Date: 11/13/2020 I hereby name and appoint De Lossing, Henry Ferguson,.Jordan Menoyo, Jessica Griffis Of:S.untuity Electri:c.LLC to be my lawful attorney-in-fact to act forme, and.apply to the Division of Building.for a Electrical / Solar permit for work to be performed at the location. : described.as and wherein the City of -Le p rWI s Owner of Property::ALL PERMITS ..: Project Address: City/State/Zip: and to sign my name and.do all things necessary to this appointment. Contractor: Nestor Montalvo nse: E 13009276 Contractor Signature The_foregoing instrument was acknowledged before me this ay Of p of 20 .Y,:b . e� �Y)& I/l) who is. ers.onall .. Y . . know to me. Notary ..-.-Seal, n . Notary.Publ'a$rate of Flo da ,g' Pamela M Grantham pres 01H.112022 17 4919 EY d X Notary Signature: 2137 Route 35 N,Holmdel,NJ 07733 1 Phone:732.979.2400 I Fax:732.979.2401 1 www.suntuity.com INS I Hrf LULU 1 OLODU UH HK I W&LP0 NCB J/ 16 Page 1 of 1 10/29/2020 10:44 AM Rcpt:2220855 Rec:10.00 DS:0.00 IT:0.00 Nikki Alvarez-Sowles,Esq.,Pasco County Clerk&Comptroller NOTICE OF COMMENCEMENT Permit No. Property Identification No.03.2e-11.01204 oaa-osso THE UNDERSIGNED hereby gives notice that improvements will be made to certain real property,and in accordance with Section 713.13 of the Florida Statutes,the following information is provided in the NOTICE OF COMMENCEMENT. 1. Description ofproperty(legal description.) a^ ee area.uuno mnurunnrtuorane eesramno ntmanmewan a) Street Address:SM FOxMODR DRIVE.ZEPWPMIS,FL 335C 2. General description of improvements buw1a16ana1n0n P'wn% 3. Owner information a) Name and address:cASrRO ALLFROD a cAsrRO TAsHA 6m Fo)(1400R DRIVE,TEPHYRHILLS.PL 33542 b) Name and address of fee simple titleholder(if other than owner) c) Interest in property owner 4. Contractor Information a) Name and address:SunWar eocar,LLc 3030 Rapddr Rd,Silto S rake",FL 33M b) Telephone No.:6tt Wfl6w Fax No.(Opt.) 5. Surety Information a) Name and address: b) Amount ofBond: c) Telephone No,: Fax No.(Opt.) 6. Lender a) Name and address: 7. Identity of person within the State of Florida designated by owner upon whom notices or other documents may be served; a) Name and address: b) Telephone No.: Fax No.(Opt) 8. In addition to himself,owner designates the following person to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b),Florida Statutes: a) Name and address: b) Telephone No.: Fax No.(Opt.) 9. Expiration date of Notice of Commencement(the expiration date is one year from the date of recording unless a different date is specified): WARNING TO OWNER:ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713,PART 1,SECTION 713.13, FLORIDA STATUTES AND CAN RESULT IN YOUR PAYING TWICE FOR IPROVEMENTS TO YOUR PROPERTY.A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION.IF YOU INTEND TO OBTAIN FINANCING,CONSULT YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOU NOTICE OF COMME�NT. STATE OF FLORIDA COUNTY OF PASCO JON CONNE ON i OF Ownerar w er's Auth6nccd Ofriccr/Director/Panner/M6nager R STyP ro"F State of Florida Notary ubllc s. Commission M GG 255103 tName My Commission Ex 485 The foregoing instrume 'w of oL eV 20 ap�by 41F&J C A SfrQ (type of authority,e.g.officer,trustee,attorney in fact)for 1 (name of parry on behalf of whom instrument was executed). Personally Known_OR Produced Identification f9< Notary Signature-- L�Ni /L-. /� Type ofldentificationProduced bfi&4C6 Ike.& Name(print) Verification pursuant to Section 92.525,Florida Statutes,Under penalties of perjury,I declare that I have rend the foregoing and that the facts stated in it are true to the best ofmy knowledge and belief. FORM&NOC—M00r ____-- TYPA ®IoTsuLTaNG Wyssling Consulting- : 76 North Meadowbrook Drive. Alpine, UT 84004 Scott-E. Wyssling,'PE,PP, CME office.(201) 874-3483 swyssling@wysslingconsulting:com. November 2, 2020 Suntuity Solar 2137 Route 35 Holmdel, NJ 07733 Re:. Engineering Services Castro Residence 6622.Foxmoor Drive, Zephyrhills FL 650 13. kW System To Whom It May Concern: Pursuant to:your:request, we have reviewed the following_information regarding solar panel installation on the roof of the above referenced-home: . . . ... I.: Site Visit/Verification:Form re ared'b .a Suntui Solar.:representative identifying:specific P P Y tY. . P 9 P site information including size and spacing of rafters1or the existing roof structure. 2. Design drawings of the proposed system including a site plan, roof;plan and connection.::. details for the solar-panels. This information was prepared by Suntuity Solar and will be utilized for approval:and construction'of the proposed system. 3. Photographs of the interior.and exterior of the roof system identifying:existing structural. . members and their conditions. Based.on the above information we have evaluated the structural. capacity of the existing roof system to support.the additional loads imposed by:the solar panels and have the following comments related to our review and evaluation: Description of Residence. The existing residence is typical wood.framing'construction with'the roof system consisting of truss,system with all chords constructed of 2 x;4 dimensional lumber at 24" on center. The attic space is unfinished and photos.indicate that.there was free access.to visually inspect the size and condition of the.roof rafters. .All.. wood material utilized for the roof system is,assumed to be Doug-Fir#2 or better with standard construction components. The existing roofing material consists of composite.asphalt shingles. Photos of the dwelling P 9 9. P P 9 9 also indicate that there is a permanent foundation. A. --Loading Criteria Used • 145 MPH wind loading based.on ASCE 7-10 Exposure Category"B"at a slope of 23 degrees sw •- 7 PSF= Dead Load roofing/framing Live Load=20.PSF/0 PSF(where:panels are installed): . • 3 PSF= Dead Load solar panels/mounting hardware Total Dead Load=10 PSF The above values:are within acceptable limits of recognized industry standards for similar structures in accordance with the (FBC 2017, 6th Edition). Analysis performed of the existing roof structure:utilizing the above loading criteria indicates that the existing rafters will support the additional panel loading without damage, if installed correctly. Page 2 of 2 B. Solar Panel Anchorage 1. The solar panels shall be mounted in'accordance with the most recent "Ecofasten Installation Manual", which can be found on the Ecofasten website (http://ecofasten.coml). If during solar panel installation, the roof framing members appear unstable or deflect non-uniformly, our office should be notified before proceeding with the installation. 2. Maximum allowable pullout per lag screw is 235 Ibs/inch of penetration as identified in the National Design Standards (NDS) of timber construction specifications -for Doug-Fir (North -Lumber) assumed.. Based on our evaluation, the pullout value, utilizing a penetration depth of 2 1/2", is less than what is allowable per connection and therefore is adequate. Based on.the variable factors for the existing roof framing and installation tolerances, using.a thread depth of 2 '/2" with a minimum size of 5/16" lag screw per attachment-point for panel anchor mounts should be adequate with a sufficient factor of safety. 3. Considering the roof slopes; the size, spacing; condition of roof, the panel supports shall be placed no greater than 48".o/c. . 4. Panel supports connections shall be staggered to distribute_load to adjacent trusses. Based on the above evaluation, it is the,opinion of this office that with appropriate;panel anchors being utilized the roof system will adequately support the additional loading imposed by the solar panels. This evaluation is.in conformance with the FBC 2017, 6th Edition,- current industry and-standards, and based on information supplied to us at the time of this report. Should you have any questions regarding the above or if you require further information do not hesitate to contact me. V truly yours; Scott E.Wyssli , PE Florida License No. THIS PLAN HAS BEEN ELECTRONICALLY SIGNED AND ,t�„tj t 9111/1!I SEALED BY SCOTT WYSSllNG,PE USING A DIGTT'.AL \� ��✓ SIGNATURE AND DATE. PRINTED COPIES'OFTWS DOCUMENT ARE-NOT CONSIDERED SIGNED AND SEALED AND THE SIGNATURE MUST BE VERIFIED �\ ,`� . .•• ._� �j� _ ... ON A14Y ELECTRONIC COPIES- -- - ` ••`G�.N Scott E 11N.' tir=sgoad by ta.L1EWyssling p ON:C=US,Wy1sh,L=Alpine,O=Wyssling Consulgng, ,1 9 CN=Smt1 E Wyssling ';E-swyssling@wysslingmnsulgng.mm 16,"a 1—the authorofthlsdocument - Wys s l i n g Lomgori:your signing locgtl T O'e 1 L '--Fote:Y020A1A21VorsT 3-0T00' -'FoxltPhgnlnmPOFVarslon:10.1.0 ► TA7t=OF O11AL 1 t1ti1 WCONSULTING ® ® � ' ® B � , - �mtmumu�muu�amn vuamm�mmuu�nu�n�m 370,-M ' uuu111111n11 Hmrmn NEW (uu�immmunmtmiu�umim uwumnmuullnnmumuum�m �uummiaw�mmtuwumm) _ uummmiWuummiuwummi uumm1muum l IIII I mim mwrmmimwim�muuwmm� uw�immuu�mmiuuurLow LID Mono, . iyu �m1 fl: I Illi 12ryear Warranty for Materials v�mtam�runwAmn (mm�,�uumamoa� . Processing; 25-year'Warranty for Extra UnearPower Output ., . 25 year Power Additional ty .. Vaiue from LO '`, Power Attenuation NGi Soiars 91.2% _- 87.7/0 ----=--^-^- -=----'.- `--- - -- lines wer llrarran11351/6 1 5 10 15 20 25 Complete System and Product Certifications Positive power tolerance(0 +5W)guaranteed 'JEC61215,IEC61730,UL61730 :.I50 9001:2008;ISO Quality Management System High module conversion efficiency(up to 20.3%) ISO 14001:zoos:ISO Environment Management system Slower.power degradation enabled by.Low LID Mono PERC technology:first year<2%, TS62941:Guideline for module design qualification and type approval 0.559/.year 2-25 9HSA518001:2007 Occupational Health and Safety - - Solid PID resistance ensured by solar cell process optimization and careful module BOM L� selection Sus �. Reduced resistive loss with lower-operating current •'Specifications subject tgtechnicat changes and tests. Higher energy yield with lower operating temperature " ..:LONGi Solar reserves the right of interpretation. - Reduced hot spot risk with optimized electrical design and lower operating current [ Room 801,Tower 3,Lujiazui Financial Plaza,No.826 Century Avenue,Pudong Shanghai,260126,China Tel:+86-21-80162606 E-mail:module@longi-silicon.com Facebook:www.facebook.com/LONGi Solar Note:Due to continuous technical innovation,R&D and improvement,technical data above mentioned may be of modification accordingly.LONG have the sole right to make such modification at anytime without further notice;Demanding party shall request for the latest datasheet for such as contract need,and make it a consisting and binding part of lawful documentation duly signed by both parties. 2020041OV11 for US-D LR4-60HPB 345~3 0 ® . ra 5 1038 Cell Orientation:120(6x20) Operational Temperature:40 C +85 C II 1 u i nut I n11 I 11111 l ❑IIII IIIIIIIJI Hill 9 Junction Box:IP68,three diodes Power Output Tolerance:0-+5W Output Cable:4mm',1200mm in length Voc and Isc Tolerance:±3% I II 1 Glass:Single glass Maximum System Voltage:DC1000V(IEC/tJL) 3.2mm coated tempered glass Maximum Series Fuse Rating:20A ^m g lT! `$ =n Frame:Anodized aluminum alloy frame Nominal Operating Cell Temperature:45±2 C 1 A-A Weight:19.5kg Safety Class:Class II I Unks:mm(infi) Dimension:1755x1038x35mm Fire Rating:ULtype1or2 I 1 ran : nM 1mm Packaging:30pcs per pallet Tole 997 Veda±celmm 1 III HNht±Imm 180pcs per 20'GP I I I I Rlfirox-xlmm 780pcs per 40'HC Model Number LR4-60HPB-345M .,LR4-60HPB-350M LR4-60HPB-355M LR4-60HPB-360.M, LR4-60HPB-365M LR4-60HPB-370M_- Testing Condition :STC: NOCT STC NOCT STC NOCT STC NOCT STC NOCT STC NOCT --- _ Maximum Power(Pmax/W) " 345 25Z.6', 350 261.4 355 I', •265:1-F 360 268.8 365 272:6 370 276:3, Open Circuit Voltage(Voc/V) T 40.2 .37:7.' 40.4 I 37.9 40.6 38.1:: 40.8 38.2 41.0 38.4 41.2 1 38.6' Short Circuit Current(Isc/A)_ 11.06" 1 8.95 11.16 9.02 11.25 9.019 i 11.33 •9:16-_; 11.41 9.23 , 11.50 9.30 Voltage at Maximum Power(Vmp/V) 34.2 j 31.8 34.4 j 32.0 34.6 321.2.- 34.8 32.4 35.0, 1 32.6 35.2 32.8 J. Current at Maximum Power(Imp/A):T 10.09 „ ,:8:09. ;10:18 8.16 10.27 ; -•8.23::i 10.35- 8.30 ):10.43.: 8.36 i 10.52 ,- 8.43 Module Eff ciency(%).. 18.9 19.2 19.5 19.8 20.0 20.3 - STC(Standard Testing Conditions):Irradiance 1000W/m7,Cell Temperature 25 C,Spectra at AM1.5 .. NOCT(Nominal Operating Cell Temperature):Irradiance 800W/m2,Ambient Temperature 20 C,Spectra,at AM1.5,Wind at 1m/SkW - Loading Temperature Coefficient of Isc +0.048%/C Front Side Maximum Static Loading 540CPa Temperature Coefficient;of Voc -0.270%/C Rear Side Maximum Static Loading 2400Pa Temperature Coefficient of Pmax -0.350%/C Hailstone Test 25mm Hailstone at the speed of 23m/s iW Curve Current-Voltage Curve(LR4-60HPB-360M) Power-Voltage Curve(LR4-60HPB-3609) Current-Voltage Curve(LR4-60HPB-360M) 12 400 Cell temp=25C 12 Cell Temp=25C 10 350 _l000w/m' 10. :lo0ow/m' .. Indent l.d.=11IM/m' 300 -800- ' 80ow/1' g' -Cell Temp=25C 3 250 d00w/m' g Q -Cell Temp=35C "' -20?/ml a 60Uw - w B -Cell Temp=45C d 200 fi -Cell Temp=55C 4 -Cell Temp=65C- o' 150 U 4 400w/m' -Cell Temp=751C 100 .. 2. 50 _ 2 200w/0 - 0 0 0 - .0 - 10 _ 20 30 40 50 0 30 20 30 40 50 0 10 20 30 40 s0 - - Voltage(v) Voltage(v) Voltage(v) N%vl Room 801,Tower 3,LujiazuI Financial Plaza,No.826 Century Avenue,Pudong Shanghai,200120,China Tel:+86-21-80162606 E-mail:module@longi-silicon.com Facebook:www.facebook.com/LONGi Solar Note:Due to continuous technical innovation,R&D and Improvement,technical data above mentioned may be of modification accordingly.LONGi have the sole right to make such modification at anytime without further notice;-Demanding party shall request for the latest datasheet for such as contract need,and make it a consisting and binding part of lawful documentation duly signed by both parties. 2020041OV11for US-D Data Sheei Enphase Microinverters Region:AMERICAS . nphase The high-powered smart grid-ready Enphase IQ 7 Micro's" and Enphase IQ 7-r Micro"" .a nd IQ 7+ dramatically simplify the installation process while ® a achieving the highest system efficiency. � roinverters Part of the Enphase IQ System,the IQ 7 and IQ 7+ Microinverters integrate with the Enphase IQ Envoy", Enphase IQ BatteryTM, and the Enphase Enlighten" monitoring and analysis software. IQ Series Microinverters extend the reliability standards,set forth by previous.generations and:: :. undergo over a million.hours of power-on testing, enabling Enphase to provide an industry-leading warranty.pf,up to 25 years. .:.Easy to Install .. Lightweight-and simple Faster installation with improved,lighter two-wire cabling Built-in rapid shutdown compliant(NEC 2014&2017). Productive and Reliable Optimized for high powered 60-cell and 72-cell*modules • More than a million hours of testing • Class II double-insulated enclosure UL listed 0 Smart Grid Ready Complies with advanced grid support,voltage and . frequency ride-through requirements -•r-• Remotely updates to respond to changing grid requirements • Configurable for varying,grid profiles • Meets CA.RuIe 21 (UL 1741-SA) ,*The IQ 7+Micro is required to support 72-cell modules. To learn more about Enphase offerings,visit enphase.com E . PHAS • Enphase IQ 7 and IQ 7+ Micr®inverters INPUT DATA(DC) IQ7-60-2-US IQ7PLUS-72-2-US Commonly used module pairings' 235 W-350 W+ 235 W-440 W+ Module compatibility 60-cell PV modules only 60-cell and 72-cell PV modules Maximum input DC voltage 48 V 60 V Peak power tracking voltage 27 V-37 V 27 V-45 V Operating range 16 V-48 V 16 V-60 V Min/Max start voltage 22 V/48 V 22 V/60 V Max DC short circuit current(module Isc) 15 A 15 A Overvoltage class DC port II II DC port backfeed current, 0 A 0 A PV array configuration 1 x 1 ungrounded array;No additional DC side protection required; AC side protection requires max 20A per branch circuit OUTPUT DATA(AC) IQ 7 Microinverter IQ 7+Microinverter Peak output power 250 VA 295 VA Maximum continuous output power 240 VA 290 VA Nominal(L-L)voltage/range2 240 V/ 208 V/ 240 V/ 208 V/ 211-264 V 183-229 V 211-264 V 183-229 V Maximum continuous output current 1.0 A(240 V) 1.15 A(208 V) 1.21 A(240 V) 1.39 A(208 V) Nominal frequency 60 Hz 60 Hz Extended frequency range 47-68 Hz 47-68 Hz AC short circuit fault current over 3.cycles 5.8 Arms 5.8 Arms Maximum units per 20 A(L-L)branch circuit' 16(240 VAC) 13(208 VAC) 13(240 VAC) 11.-(208 VAC) Overvoltage class AC port III III AC port backfeed current 18 mA 18 MA Power factor setting 1.0 1.0 Power factor(adjustable) 0.85 leading...0.85 lagging 0.85 leading...0.85 lagging EFFICIENCY @240 V @208 V @240 V @208 V Peak efficiency `ry � - - -97.6% 97.6% -� 97.5% 97.3% .�����~��� CEC weighted efficiency 97.0% 97.0% 97.0% 97.0% MECHANICAL DATA Ambient temperature_range_____ -400C to+65°C Relative humidity range 4%to 100%(condensing) Connector type MC4(or Amphenol H4 UTX with additional Q-DCC-5 adapter) Dimensions(HxWxD) 212 mm x 175 mm x 30.2 mm(without bracket) Weight 1.08 kg(2.38 Ibs) Cooling Natural convection-No fans Approved for wet locations Yes Pollution degree PD3 Enclosure Class II double-insulated,corrosion resistant polymeric enclosure Environmental category/UV exposure rating NEMA Type 6/outdoor FEATURES Communication Power Line Communication(PLC) Monitoring Enlighten Manager and MyEnlighten monitoring options. Both options require installation of an Enphase IQ Envoy. Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load-break disconnect required by NEC 690. Compliance CA Rule 21 (UL 1741-SA) UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO.107.1-01 This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems,for AC and DC conductors,when installed according manufacturer's instructions. 1.No enforced DC/AC ratio.See the compatibility calculator at https:Henphase.com/en-us/support/module-compatibility. 2.Nominal voltage range can be extended beyond nominal if required by the utility. 3.Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. To learn more about Enphase offerings,visit enphase.com ENPHASE. ©2020 Enphase Energy.All rights reserved.Enphase,the Enphase logo,Enphase IQ 7,Enphase IQ 7+,Enphase IQ Battery, Enphase Enlighten,Enphase IQ Envoy,and other trademarks or service names are the trademarks of Enphase Energy,Inc.Data subject to change.2020-01-06 ROCK-IT SYSTeM 3.0 Designed with the installer in mind. EcoFasten Solar specializes in solar roof attachments that are fast and easy to install,straightforward,secure and cost-effective.Eco Fasten offers a wide variety of standard products as well as custom solutions,for a one-stop source for all of your rooftop anchoring needs.Products are rigorously tested and approved above and beyond industry standards in4wuse and by third party agencies.Ecol=asten°s patented c®nicaE sealing systern has.been in service in the snow guard and solar industries for over two decades. FeaTures - New and improved design - North-South adjustability- Fastest,easiest to level system on the market - Only one tool required 0/2-deep viell socket) Integrated electrical bonding - Vertical adjustment of3'-4' SIMPLE-only 4 components SgST.Qm comPonenTS* - RequlreD MI • .. .. ROCK_-IT SLIDe ROCK-IT 3.0: ROCK-IT 3.0 ROCK-IT 3.0 4, Or 8" I ounT COUPLIr1G anD Array SKIrT -W,W_';; LOAD BearinG FOOT SYSTem comPonenTS* - oPTIonaL t aK EcoFasten :J ROCK-IT CUP SS Solar 1 (ReFerTO PG.7) Ecol'astenSolarproducts are protectedbythefollowing .'. U.S.Patents:. 8,151,522 8,153,700 8,181,398 8,-166,713.8,146,299 8,209,914'8,245,454 8,272,1A 8,225,557 0,010,038 . ROCK-IT 3.0 ti ROCK-IT 3.0 9,134,040 9,175,4789,212,833 HyBrID MOUIIT Array SKIT-r (ReFerTO PG.5) Er1D,CaPS (EnD caps come ROCK-IT CLIP 2.0 Pre=insraLt_eD on EasT .. . . . . (ReFer TO PG.7) eno of sKir r secTlons) www.ecofastensolar.com info@ecofastensolar.com 877-859-3947 1 Data Sheet Enphase Networking nphase The Enphase IQ Combiner 3' with Enphase IQ Envoy"' consolidates interconnection iner equipment into a single enclosure and (X-IQ-AM1-240-3) streamlines PV and storage installations by providing a consistent, pre-wired solution for residential applications. It offers up to four 2-pole input circuits and Eaton BR series busbar assembly. Smart d' Includes.IQ Envoy for communication and control n;; 1. Flexible networking supports Wi-Fi, L © - © 1' Ethernet,or cellular LI' Optional AC receptacle available for PLC a ' ; bridge j� ;K i• �' -. Provides production metering and optional consumption monitoring Simple •\ Reduced size from previous combiner ' Centered mounting brackets support single •. f stud mounting • Supports back and side conduit entry • Up to four 2-pole branch circuits for 240-VAC I�� u plug-in breakers(not included) • 80 A total PV or storage branch circuits. Reliable • Durable NRTL certified NEMA type . 3R enclosure U� • Five-year limited warranty • UL listed LISTED To learn more about Enphase offerings,visit enphase.com E N P HAS E• Enphase IQ Combiner 3 MODEL NUMBER IQ Combiner 3 _.____ ._ ^_ __IQ Combiner 3 with Enphase IQ Envoy'printed circuit board for integrated revenue grade PV X-IQ-AM1-240-3 production metering(ANSI C12.20+/-0.5%)and optional*consumption monitoring(+/-2.5%). ACCESSORIES and REPLACEMENT PARTS(not included,order separately) -_._.._._ ___�. -_Co______' Enphase Mobile Connect" CELLMODEM-03(4G/12-year data plan) Plug and play industrial grade cellular modem with data plan for systems up to 60 CELLMODEM-01 (3G/5-year data plan) microinverters.(Available in the US,Canada,Mexico,Puerto Rico,and the US Virgin Islands, CELLMODEM-M1 (4G based LTE-M/5-year data plan) where there is adequate cellular service in the installation area.) Consumption Monitoring*CT Split core current transformers enable whole home consumption metering(+/-2.5%). CT-200-SPLIT *Consumption monitoring is required for Enphase Storage Systems Wireless USB adapter Installed at the IQ Envoy.For communications with Enphase Encharge'storage and Enphase COMMS-KIT-01 Enpower'°smart switch.Includes USB cable for connection to IQ Envoy or Enphase IQ Combiner" and allows redundant wireless communication with Encharge and Enpower. Circuit Breakers Supports Eaton BR210,BR215,BR220,BR230,BR240,BR250,and BR260 circuit breakers. BRK-10A-2-240 Circuit breaker,2 pole,10A,Eaton BR210 BRK-15A-2-240 Circuit breaker,2 pole,15A,Eaton BR215 BRK-20A-2P-240 Circuit breaker,2 pole,20A,Eaton BR220 EPLC-01 Power line carrier(communication bridge pair),quantity-one pair XA-PLUG-120-3 Accessory receptacle for Power Line Carrier in IQ Combiner 3(required for EPLC-01) XA-ENV-PCBA-3 Replacement IQ Envoy printed circuit board(PCB)for Combiner 3 ELECTRICAL SPECIFICATIONS Rating Continuous duty System voltage 120/240 VAC,60 Hz Eaton BR series busbar rating 125 A Max.continuous current rating(output to grid) 65 A Max.fuse/circuit rating(output) 90 A Branch circuits(solar and/or storage) Up to four 2-pole Eaton BR series Distributed Generation(DG)breakers only(not included) Max.continuous current rating(input from PV) 64 A Max.total branch circuit breaker rating(input) 80A of distributed generation/90A with IQ Envoy breaker included Production Metering CT 200 A solid core pre-installed and wired to IQ Envoy MECHANICAL DATA Dimensions(WxHxD) ___ 49.5 x 37.5 x 16.8 Tcm(19.5"x 14.75"x 6.63").Height is 21.06"(53.5 cm with mounting brackets). Weight 7.5 kg(16.5 Ibs) Ambient temperature range -400 C to+460 C(-400 to 1150 F) Cooling Natural convection,plus heat shield Enclosure environmental rating Outdoor,NRTL-certified,NEMA type 3R,polycarbonate construction Wire sizes 20 A to 50 A breaker inputs: 14 to 4 AWG copper conductors • 60 A breaker branch input: 4 to 1/0 AWG copper conductors • Main lug combined output: 10 to 2/0 AWG copper conductors • Neutral and ground: 14 to 1/0 copper conductors Always follow local code requirements for conductor sizing. Altitude To 2000 meters(6,566 feet) INTERNET CONNECTION OPTIONS Integrated Wi-Fi 802.11b/g/n � � Ethernet Optional,802.3,Cat5E(or Cat 6)UTP Ethernet cable (not included) Cellular Optional,CELLMODEM-01 (3G)or CELLMODEM-03(4G)or CELLMODEM-M1(4G based LTE-M) (not included) COMPLIANCE Compliance,Combiner UL 1741, CAN/CSA C22.2 No.107.1,47 CFR,Part 15,Class B,ICES 003 Production metering:ANSI C12.20 accuracy class 0.5(PV production) Compliance,IQ Envoy UL 60601-1/CANCSA 22.2 No.61010-1 To learn more about Enphase offerings,visit enphase.com ©2018 Enphase Energy.All rights reserved.Enphase,the Enphase logo,IQ Combiner 3,and other trademarks or service names are the trademarks of Enphase Energy,Inc. P H /tl S E• 2019-11-04 /'1 D nip FUMED TV ROOF44OUNT COMMER[ENCLOSUIRE Basic Features 6 Stamped Seamless Construction •• - ' ' 18 Gauge Galvanized Steel • Powder Coated Surfaces ' Flashes into.the roof deck ` • 3 Roof deck knockouts .5"; .7511, 1" - • 5 Centering dimples for entry/exit fittings or conduit • 2 Position Ground lug installed • Mounting Hardware Included SolaDeck Model SD 0783 SolaDeck UL50 Type 311 Enclosures Available Models: Model SD 0783-(3"fixed Din Rail) =� f Model SD 0786-(67 slotted Diri Rail) SolaDeck UL 1741 Combiner/Enclosures Models SD 0783-41 and SD 0786-41 are labeled and ETL listed UL STD 1741 according to the UL STD 1741 for photovoltaic combiner enclosures. Max Rated-60OVDC, 120AMPS Model SD 0783-41 3" Fixed Din Rail fastened using Norlock System Typical System Configuration ' -- - 4-Din Rail Mounted Fuse Holders 60OVDC 30 AMP 1- Power Distribution Block 60OVDC 175AMP . - 1-Bus Bar with UL lug Model SD 0786-41 6"Slotted Din Rail fastened using steel studs. **Typical System Configuration 4-Din Rail Mounted Fuse Holders 60OVDC 30 AMP 4-Din Rail Mounted Terminal Blocks Bus Bars with UL lug **Fuse holders and terminal blocks added in the field must be,UL listed or d recognized and meet 600 VDC 30 AMP 110C for fuse holders,600V 50 AMP =" 90C for rail mounted terminal blocks• and 600 V 175 AMP 90C for-Power Distribution Blocks. Use Copper Wire Conductors. r Cover is trimmed to allow Model SD 0783-41,wired with Model SD 0786-41,wired with conduit or fittings, base is Din Rail mounted fuse holders, Din Rail mounted fuse holders, _ center dimpled for fitting bus bar and power distribution terminal blocks and bus bars. locations. block. RSTC Enterprises, Inc , 2219 Heimstead Road .Eau Cliare, Wl 54703 For product information call 1(866) 367-7782 a Light Duty Safety Switches by Schneider Electric Class 3130/Refer to Catalog 3100CT1602 s ch ne lder-electric.us Light Duty—Visible Blades 10 kA Short Circuit Current Rating The Square D light duty enclosed switch is ideal for home applications in disconnecting power to workshops,hobby rooms,furnaces,and garages.The light duty safety switch has visible blades and a ground lug as standard features. Table 3.1:Fusible K'9evrs--�n6i-w 2 Wire(1 Blades and Fuseholders,1 Neutral)7120 Vac 30 Plug .. L111N L221N 3 Wlre(2 Blades and'Fuseholders,l Neutral)-120/240 Vac Q Q Plug L211N 1/2 2 1-1/2 3 30 Cart L221N 1/2 2 1-1/2 3 General Duty—Up To 100 kA Short Circuit Current Rating General duty safety switches are designed for residential and commercial applications where durability and economy are prime considerations.Typical loads are lighting,air conditioning,and appliances.They are suitable for use as service equipment when equipped with a factory or field-installed neutral assembly or a field-installed service grounding kit,(see page 3-5)as applicable. General duty safety switches are UL Listed,File E2875,and'meet or exceed the NEMA Standard KS1. 240 Volt—Single Throw Fusible Switches Table 3.2:Fusible i - i 2 Wire(1 Blade and Fuseholder l Neutral)-120 Vac, { 4 30. Plug Use Light Duty Device for this Application C (see above) - }8 30 Cart. Use three-wire devices for this application. L3 Wlre 2 Blades and Fuseholders,1 Neutral '120/240 Vac Plu)240 Vac Cart Maximum — 'ii 30 Plug D211N D211NRB — 1-1/2 — 3 7-1/2 D223N Q 4 30.. Cart. D221N D221W13 DRK30 1-1/2 3[3] 3 [31 S4/ 60, Cart. D222N D222NRB RFK03H 3 7-1/2[31 10 1513] b b 100 Cart. D223N D223NRB RFK10 7-1/2 15[3] 15 30[3] b 200 Cart. D224N.[4] D224NRB[4] HRK1020 15 25[3] 60[3] 400 Cart. D225N D225NR DRK40 — — — — 600[51 Cart. D226N D226NR DRK600_ — i 4 Wire 3 Blades and Fuseholders,1 Neutral 240 Vac Maximum 30 Cart. D321N D321NRB DRK30 1-1/2 3 3 7-1/ 2 60 Cart. D322N D322NRB RFK03H 3 7-1/2[61 10 15[6] 100 Cart. D323N D323NRB RFK10 7-1/2 15[6] 15 30[6] 200 Cart. D324N[4] D324NRB[4J HRK1020 15 25[6] — 60[6] 400 Cart. 1)325N D325NR DRK40 50 125 400(7] Class T D325NT D325NTR 50 600[5] Cart. D326N D326NR DRK600 75 150 600171 Class T D326NT D326NTR 75 800[71 1 Class T I T327N T327NR 100 [1] Bolt-on hubs—Referto Rainproof Bolt-On Hubs,Table 1.27,page s-1A. [2] When properly Installed,the Class R Fuse Kit rejects all but Class R fuses. 13] For comer grounded delta systems only.Use switching poles for ungrounded conductors.See data bulletin 270ODBO202 far additional information. 14] For 200%neutral,order(1)additional neutral kitSN20A and(1)neutral jumper kit SN20NI. [51 Order Class J Fuse Kit GDJK600 if using Class J fuses. [61 If comer grounded delta,use outer switching poles for ungrounded conductors. [7] D325NT,D325NTR,D326NT,D326NTR,T327N and T327NR accept only 300Vac Class T fuses. ©2018 Schneider Electric 3-3 All Rights Reserved 0 810 612 01 8 General Duty Safety Switches General Duty—Up to 100 kA Short Circuit y Current Rating by Schneider E l eccr lc Class 3130/Refer to Catalog 3100CT1602 schnelder-electric.us 240 Volt—Single Throw Non-Fusible Switches Table 3.3:Non-Fusible I 2 Wire(2 Blades)-240 Vac Maximum ... 30 DU221RB - 3 p 60 DU222RB 10 I 60 Q0260NATS [9][10] Q0200TR [9][10][11] 10 — r� 100 Q02000NS [9][101 Q02000NRB[9][111 20 — b 200 Use 3P Switch Use 3P Switch 400 Use 3P Switch Use 3P Switch 600 Use 3P Switch Use 3P Switch &Wire(3 Blades�240 Vac Maximum _ - -- - — __ _-, — -- -- _----- -- -— — - 30 DU3_.21 DU321 RB 3 7-1/2 O a O 60 DU322 DU322RB 10 15 I/ 100 DU323(12] DU323RB(12] 15 40 200 DU324(131 DU324RB(13] 15 60 bbb ddd E 400 DU325 125 600 DU326(14] 150 UL Listed Maximum Short Circuit Current Ratings—AC Only Table 3A Fusible Safety Switch Short Circuit Current Rating Plug 10 kA H,K 10 kA J(151,R 100 kA T(16] 100 kA Non-Fusible Safety Switches Systems equal or less than 10 WR SCCR Any brand of circuit breaker or fuse not exceeding the ampere rating of the switch may be used in conjunction with a non-fusible safety switch. Systems above 10 WR SCCR—The UL Listed short circuit current rating for Square D non-fusible switches is based upon the switch being used in conjunction with fuses or Square D circuit breakers or Mag-Gard motor circuit protectors. Table 3.5:Non-Fusible Safety Switch Short Circuit Current Rating Any Brand Circuit Breaker 10 kA H or J Powerl act Circuit Breaker Up to 65 kA(18] H,K 10 kA J,R 100 kA[19] T 100 kA[20] 18] Bolt-on hubs—Refer to Hubs,page 5-1 A. 191 Enclosed molded case switch—Refer to Section 1. [10] Includes factory-installed grounding kit. (11] Not service entrance rated—Refer to hole u.sa for more Information. 114 If a neutral assembly is required,order and field Install SNO610. [13] If a neutral assembly Is required,order and field install a SN20A Neutral Assembly Kit.For a 200%neutral application,order and field Install(2)SN20A Neutral Assembly Kits and(1) SN20NI Neutral Jumper Kit. [14] If a neutral assembly Is required,order and field Install D600SN. [15] Only applicable to 200 A-600 A except D325NT,D325NTR,D326NTand D326NTR. [16] Only applicable to D325NT,D325NTR,D326NT,D326NTR,T327N and T327NR. (171 Ampere rating of fuse or circuit breaker not to exceed switch ampere rating. (181 Only applicable to DU324 and DU324RB.HD,JD=25 kA maximum. (191 SCCR=50 kA,applicable to DU222RB,DU322 and DU322RB. 1201 Only applicable to DU323,DU323RB,DU325 and DU326. 3-4 ©2018 Schneider Electric All Rights Reserved 0 810 6/201 8