Loading...
HomeMy WebLinkAbout20-1082 • m OntOn City of Zephyrhilis PERMIT NUMBER a. P ...,. . 5335 Eighth Street Zephyrhills, FL 33542 BNR-001082-2020 Phone: (813)780-0020 Ff. Fax: (813)780-0021 Issue Date: 12/15/2020 Permit Type: Building New (Residential) Streeet Address 6880 Shelby Lynn Way ,wij r Information, =. y Perm_it;lnformation C„�ontractor ln_formation Name: LINKS AT CALUSA SPRINGS LLC Permit Type:Building New(Residential) Contractor: K HOVNANIAN FLORIDA Class of Work:SFR Construct OPERATIONS LLC Address: 2301 Lucien Way 260 Building Valuation:$172,287.00 MAITLAND,FL 32751 Electrical Valuation:$6,300.00 Phone: Mechanical Valuation:$5,200.00 \ Plumbing Valuation:$5,900.00 ,n Total Valuation:$189,687.00 0 Total Fees:$14,979.71 � Amount Paid:$14,979.71 Date Paid:12/15/2020 12:40:18PM Project Desc iption, CONSTRUCT SINGLE FAMILY 2,790 SQ FT LINKS AT CALUSA �Apphcation Fees : _ Building Permit Fee $891.44^Mechanical Plan Review Fee $33.00 Electrical Plan Review Fee $35.75 Irrigation 3/4 Meter(Calc) $732.71 Water Connection Residential Fee $1,010.00 Public Safety Impact Fee-Admin $26.35 Address Fee $30.00 Public Safety Impact Fee-Police $254.00 Sewer Connection Residential Fee $2,090.00 Driveway Fee $45.00 SIF 1 percent Fee $83.28 Plumbing Permit Fee $69.50 Mechanical Permit Fee $66.00 Building Plan Review Fee $445.72 3/4 Water Meter Fee(Calc) $732.71 Electrical Permit Fee $71.50 Plumbing Plan Review Fee $34.75 School Impact Fee $8,328.00 REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each subsequent reinspection. Notice: In addition to the requirements of this permit,there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permit required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications add fee Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. 'rRA OR SIGNA-VAE PE IT OFFICE PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER INVOICE1111 14. FOR CITY O; ZEPHYRHILILS BILLING CONTACT lid JAMES CLARK K HOVNANIAN FLORIDA OPERATIONS LLC 2301 LUCIEN WAY STE 260 MAITLAND, FL 32751 I INVOICE NUMBER INVOICE DATE INVOICE DUE DATE INVOICE STATUS INVOICE DESCRIPTION INV-00002046 12/08/2020 12/08/2020 Due NONE REFERENCE NUMBER FEE NAME TOTAL BNR-001082-2020 3/4 Water Meter Fee(Calc) $732.71 Address Fee $30.00 Building Permit Fee $891.44 Building Plan Review Fee $445.72 Driveway Fee $45.00 Electrical Permit Fee $71.50 Electrical Plan Review Fee $35.75 Irrigation 3/4 Meter(Calc) $732.71 Mechanical Permit Fee $66.00 Mechanical Plan Review Fee $33.00 Plumbing Permit Fee $69.50 Plumbing Plan Review Fee $34.75 Public Safety Impact Fee-Admin $26.35 Public Safety Impact Fee-Police $254.00 School Impact Fee $8,328.00 Sewer Connection Residential Fee $2,090.00 SIF 1 percent Fee $83.28 Water Connection Residential Fee $1,010.00 6880 Shelby Lynn Way Zephyrhills,FL 33542 SUB TOTAL $14,979.71 REMITTANCE INFORMATION TOTAL $14,979.71 City of Zephyrhills 5335 8th Street Zephyrhills, FL 33542 December 08,2020 5335 8th Street,Zephyrhills,FL 33542 Page 1 of 1 I ai �sa0020 City of Zephyrhills Permit Application FAX-813a$0-0021 Building-Department Date Received Phone Contact for Permittin ' 407 257 , owneesNariie LINKS AT_CALUSA SPRINGS. LL' ownerPhaneNumber 407-257-6940 .Owner's Address 2301 Lucien Way, Ste 260 Owner Phone Number Fee simple Titleholder Name N/A Owner Phone Number Fee Simple:Titleholder Address NIA .ros ADDRESS t,3'a 2e.j2k M rh`r 1l S. i'L.33 2 LOTS SU61*lsioly LINKS AT CALUSA SPRINGS 1 PARCEL ID#04-26-21-0260- 0000.0) (OBTAINED_ FROM PROPI*WTAKNOTICE) WORK PROPOSED NEW CONM� ADDIALT � SIGN � � DEMOLISH •INSTALL REPAIR PROPOSED USE SFR X COMM OTHER TYPE OF CONSTRUCTION BLOCK [ FRAME U STEEL Q aESCRiPT161NO owoRK NEW SINGE FAMIILY.HOME TotalSqf � } BUILDING SIZE. OTAL Under Rooms - °SQ FOG►tAGE �ng��-�1 HEIGHT BUILDING $ VALUATION OF TOTAL.CONSTRUCTION ELECTRICAL AMP SERVICE150 PROGRESS°ENERGY C] WA.E.C. ZIPLUMSING $5,900.00 MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION L]GAS [ ROOFING 'Q SPECIALTY C] OTHER FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA C]YES® NO- BUILDER` COMPANY SIGNATURE -� �3 REGISTERED Y! N F>EeuRKl+:_ Y./;N_ Address License.# ELECTRICIAN .:COMPANY SIGNATURE ( —'� y REGISTERED Y/. N . FEE CURREN Y 1 N .Address gg����I�11 License 1RILUIPI8Erit _ h 3rt� h COMPANY -f C.anclm"c4 �' S SIGNATURE *'` �L REGISTERED Y7'N 'FEE Y!N Address P.O. lab x 1'1 c y r_�l Uer FL 33v2') ..Ucense# 0 o o a 4,) -202 0� -lY .1 MECHANICAL F COMPANY SIGNATURE ~�^ REGISTERED' Y! N FEE CORREN Y!N Address Ucense# F__ I -tHERROOFER COMPANY SIGNATURE ( T�`9. REGISTERM I Y! N-, Fad WRR&\ Y l.N Address Ucense# RESIDENTIAL Attach'(2)Plot Plans; Building Plans;'(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(16)working:days aftersubmittal date. Required onsite,Construdliion Ptaris;.Stbimwater Plans W/.Slit Fence installed, Sanitary FaciliUess&1 dumoMbi—,,Site Work Permit for*subdivisionsliarge projects: COMMERCIAL Attach(2)'complete sels of Building Plans plus'a Life Safety Page;(1)set:of Energy Forms:R-O-W Permit for.;new.canstruction.. Minirm.0I4eh(10)Worldfig days after submittal date. Required onsite;Construction Plans„St6rrnwatO Plans wl Silt Fence instalied, Sanitary Facilities&1 dumpster.Site Work Permit for all new projects:All commercial requirements must meetoompliance SIGN PERMIT Attach(2)sets of Engineered Plans. ""PROPERTY SURVEY required fordll NEW.construction. .;Dirrections: . Fill out application completely Owner&Contractbr sign:babk of application,notarized If over O500,a Notice of Commencement is requir(id. .WC upgrades over$7600) Agent(far the contractor).or Power of Attorney(far the owner)would,be someone with notarized letter from owner authorizing,same 'OVER7HE COUNTER,PERMITTiNG (copy of contract required) Retools if shingles Sewers Service Upgrades AIC ' Fences(Plot1Survey/Footage) Driveways-N6t over Counter if on public roadways-needs ROW h� 613-780-0020 City of Zephyrhills Permit Application Fax-813 780-0021 Building Department Date Received Phone Contact for Permitting F, 407 257 _6940 Owners Name LINKS AT CALUSA SPRINGS. LLC Owner Phone Number 407-257-6940 Owner's Address 2301 Lucien Way, Ste 260, Maitland FL 32751 Owner Phone Number Fee Simple Titleholder Name NIA Owner Phone Number Fee Simple Titleholder Address N/A JOB ADDRESS & h e l L r'1 r% Uo,:j Z e ?n r h,11.5 FL 3354 LOT# SUBDIVISION LINKS AT CALUSA SPRINGS PARCEL ID,1 04-26-21-0260-00000 eel y 0 (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED ® KNEW CONm 8 ADD/AL'T SIGN DEMOLISH INSTALL REPAIR PROPOSED USE ® SFR X Q COMM i i OTHER TYPE OF CONSTRUCTION ® BLOCK Q FRAME STEEL C] DESCRIPTION OF WORK NEW SINGLE FAMILY HOME Total Sq F ,g°l c3 TOTAL Under Roo Lilting BUILDING SIZE .00 SQ FOOTAGE HEIGHT C� ®BUILDING kfflTr7$ as VALUATION OF TOTAL CONSTRUCTION MELECTRICAL $ 6,300,00 AMP SERVICE 160 PROGRESS ENERGY W.R.E.C. MPLUM31NG $ 5,900.00 [K]MECHANICAL $ 5,200.00 VALUATION OF MECHANICAL INSTALLATION =GAS ® ROOFING F7 SPECIALTY OTHER FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES ®NO BUILDER COMPANY K HOVNANIAN FLORIDA OPERATIONS,LLC SIGNATURE � 4-M.— �^'�' REGISTERED Y/ N FEEOLIRREI, LILNJ Address 2301 Lucien Way,Ste 260,Maitland FL 32751 License#1 CBC1263047 ELECTRICIAN gy COMPANY ROBERSTON ELECTRICAL SERVICES,INC SIGNATURk 's 1• REGISTERED Y/ N FEE CURREp Y!N Address 16812 Silver Shoves Lane Odessa FL Licesise# EC13002645 PLUMBER ._ COMPANY BAYONET PLUMBING,HEATING&AIR-COND.LL SIGNATURE ( ' - REGISTERED Y 1 N FEE CURRD LyjN Address P.O.Box 5308,Bayonet POlrlt,FL34674 License# CFC042998 � MECHANICAL COMPANY *`EAIR:F:LOW DESIGNS,INC. SIGNATURE $ «. REGISTERED Y I N FEE CURREN LUNJ Address 250 Jasmine Rd.,Casselbeny FL 32707 71 License# CAC1814423 QTHER ROOFER COMPANY HUGH MACDONALD/ALVAREZ ROOFING 41ONATURE REGISTERED YIN FEE GURREA Y t N Address 10825 Tom Folsom Rd.,Mmotmassa FL 33592 License# I CCC1329562 RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plan;(1)set ofEnergy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date. Required iinslte,Construction Plans,Stormwater Plans w/Silt Fennce fr s ll'ed, Sanitary Facilities&1 dumpster,Site Worts Permitfor subdivislonsliarge projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction. Minimum.ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans wl Silt Fence installed, Sanitary Facilities&11 dumpster.Site-Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets.of Engineered Plans. ""PROPERTY SURVEY required for all NEW construction. Directions: Fill out application completely. Owner&Contractor sign back k of application,notarized If over$2500,a Notice of Commencement Is required. (ACC upgrades over$7500) Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized fetter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences(PlotlSurveyiFootage) Driveways-Not over Counter if on public roadways..needs ROW PI¢a5¢ a :rrrigA-hot) SQbCor,.lr%r-+Car, Grovnclscapes 'Soc. /ba�`t2. D Q L a 4 i V Single Family Dwelling Plan Review Comments 1. F:F.E.. shall.be a minimum of 8" above the road elevation and an engineered site plan. 2: Lots shall be graded to comply with.R401.3 of the F.-B.C. 3: Compaction test required if 24"or:more of fill dirt is brought in at any one place. -4: Tie in survey required before pouring concrete: 5. Driveways require.a R.O.W. use permit. All 4 sides of driveway thru the sidewalk shall have expansion material. 6. All setbacks shall be met. 7. All property markers shall be uncovered and marked at time of first inspection. 8: All A.D.A.'requirements shall be met: 9-. No electric,plumbing,mechanical, or.framing shall be:covered without an inspection and approval first. 10: All Garages shall comply with section R302:6 of the,F.B:C. (Fire Separation).: 11. Appliances shall.not be'installed in a location where_subject to meclanical.damage unless protected by approved barriers. M3034 of the F:B.0 12. Water heaters shall:comply with section P607.3 of-the F.B.C. 13. Foundation supports for A/C units shall be raised at least 3" above fnished grade. M1308:1 14. Return air in.all bedrooms. F.B.C. M1620.4 15. Smoke detectors are to be installed in accordance witli_R313:1 of the.F.B.C.. 16: All glazing reguirenients are to be in accordance:with R308.4 of the F.B.C: 17. All means of egress are to be in accordance with R3l l of the RB.C. 18. "Green gypsum-board"shall not be used as a backer=in showers or tubs. R702:4.2 F:&C. 10 Co,m* bination-type AM breakers are required at all locations requiring an AM type breaker. 20. Carbon monoxide alarms will be required in new construction that uses fossil-burning heating or appliances or an attached garage. They shall be installed in accordance-with the F.B.C. 2.1. All plumbing,mechanical; and electrical shall'be separate from unit to unit: This includes all underground plumbing and electric. 22. All 2016 N.E.C. Codeswill be enforced: 21 Tamper- Resistant.Receptacles in accordance with 406.11 of the 2016 N.E.0 24. In accordance with the Land Development Code,lots shall be-sodded before final at least 10 feet around the structure. 25:.R403.5.3Hot water.pipe insulation Insulation forhot;water pipe with a minimum thermal resistance (R-value) of R-3 shall be applied to the follovving:. Piping'14 inch (19.1 mm)and larger in nominal diameter. Piping serving more than:one dwelling unit. Piping located outside the conditioned space. Piping from the water heater to a distribution manifold: Piping located under a floor slab. Buried in piping. Supply and return piping in recirculation systems other than demand recirculation systems. 25. Blower door test shall be provided before C.O. 26 A copy of the energy cacls shall be with'permit at all times 27.. Copy of final insulation report shall be provided with permit before rinab 28.No fenee, pool or screen enclosure :is issued with:this permit. F.F.E.-Finished Floor Elevation F.B.C- Florida Building Code 6th Edition R.O.W.-Right of Way A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code(2016) 4v PASCO COUNTYLORIDA Permit No. Date Permitted 'Builder Name/owner Name I t"Control#• " 'r • r rIf/� r County Parcel No. 67 2W*1 b660QD7C(p'.. SubDiv: yI CL'I`cA9►u$ Address/Location t: Lf Lunn IA" ClassiticatioNType of Use) 4M["IV TRANSPORTATION IMPACT FEE Rate: Sq.Ft Unit: Exempt []1(es Q No How Determined Impact Fee Amount 4c�- Zone No. TAM SCHOOL IMPACT FEE C��/ E Account (058) Slrigle=Family Detached House Amount $ �, r l ( . (057) Mobile Home (058) Other Residential 4 123) Collection Fee Exempt a"Yes. E]No How Determined PARKS'AND.RECREATIOWFEE. Land Account Land Credit Land Total Recreation Account Recreation Credit Recreation Total Zone TOTAL.AMOUNT Exempt Yes O No How DeteftlneA LIBRAI FEE Land Account Land Credit Land Total Facility Account Facility Credit Facility Total Exempt Yes No How Determined Total`Amou . RESOURCE'FEE ERU TOTAL AMOUNT Prepared By _ Checked By NO CERTIFICATE OF;O,CCUPANCY.WILL BE;ISSUEQ OR:FINAL INSPECTION PERFOR D UNTIL THE TOTAL"AlOOt1NTS"L ISTED HAVE BEEN PAID AND: RECEIPTED FOR BY A CENTRAL;PERMITTINO`OFFICE•OF PASCO,COUNTY Ackitowledgement;below.doesnot Unply.sccaptance of cancunenoe,but s"ply receipt of a copy<of thla;form,placing tl�e penult owner"on'notice of this esseseinent and thq conditions of payment for same. DATE RECEIVED BY RECEIPT NO. DATE BY NOTICE'OF DEED RESTRICTIONS: The undersigned understands that this permit may subject to"deed"restrictions° which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work,they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor maybe cited for a misdemeanor violation under state law. If the owner or intended contractor-are uncertain as to what licensing requirements may apply for the intended work,they are advised to contact the Pasco CountyBuilding Inspection Division—Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he .is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. if you, as the owner sign as the contractor, that may be an indication that he is.not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACTIUTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be.paid prior to receiving a "certificate of occupancy"or final power release. if the project does not involve a certificate of occupancy or final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County.Water/Sewer impact fees are due,they must be.paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713,Florida Statutes,as amended): If valuation of work is$2,500:00 or more l certify that 1, the applicant; have been provided with a. copy of the "Florida Construction Lien Law--Homeowner's Protection Guide"prepared by the Florida'Departmerit of Agriculture and Consumer Affairs. If the applicant is someone other than the°owner", I certify that1 have-obtained a copy of the above described document and promise in good faith to deliver it to the"owner"prior to commencement. CONTRACTOR'SIOWNEWS'AfFIDAVIT:` .I,certify,that-.all.the information in this application is accurate and that all work Will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to -obtain a permit to do work and `installation as indicated. I certify that no work.or installation has commenced prior to issuance of a permit and that:all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that i understand that the regulations of other-'government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: - Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands,WaterMlastewater Treatment. , - Southwest Florida Water Management District Wells, Cypress Bayheads, Wetiand Areas, Altering Watercourses. - Army Corps of Engineers-Seawalls,Docks, Navigable Waterways. - Departrrtent of Health & Rehabilitative Serves/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. - US Environmental Protection Agency-Asbestos abatement. - Federal Aviation Authority-Runways. I understand that the•following restrictions.apply to the use of fill: Use of fill is not allowed in Flood Zone"V"unless expressly permitted. If the till material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume"will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. If the fill material is to be.used'in Flood Zone "A" in connection with a permitted building using stem wall construction;I certify that fill will be used only to fill the area within the stem wall. If fill material is to be used in any area; I certify that use of such fill will not adversely affect adjacent properties. -If use of fill is found to adversely affect adjacent properties,the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one(1) acre wtiich,are,,elevated by fill,an engineered drainage plan is required. If I am.the AGENT,FOR�THE:OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit'prlor to commencing.construction. I understand thata separate permit may be required for electrical work, pfumhingaigns,`wells; pools, air conditioning, gas, or other installations not specifically included in the application. A permit W46d shall be construed to be a license to proceed with the'work and not as authority to violate,.cancel, alter,or set aside=any provision ';of-thd�W&nical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring-arcorrectionW errors°in plans,construction or violations of any codes: Every permit issued shall become invalid unless the vuork.authorized:by such permit is commenced within six months of permit issuance, or if work authorized�by the perMitis suspended er abandoned for a period of six(6)months after the time the work is commenced. An extension may be requested, in writing,from the Building Official for a period-not to exceed ninety(90)days and will.demonstrate justifiable cause for the extension; °if work ceases for ninety(90)consecutive days,the job is considered abandoned. WARNING TO OWNER:.. YOUR,-FAILURE TO RECORD A NOTICE OF.COMMENCEMENT MAY RESULT IN YOUR PAYING WACE'FO$ 1MPR0V1=1U(I=NTS TO YOUI PROOfATTY.'=IF YOU INTEND TO-OBTAIN FINANCING,CONSULT WITH YOURLENDER OR AN-ATTORIVEY`BEFORE'RECORDING YOUR'NOTiCE'OF COMMENCEMENT. FLORIDA URAT tFJ- 1,7.103) O ER OR AGENT CONTRA•TO Su scd edandsworaffirm before a this Su scri� to��ffo�raffirme--d))__beforemethis b S MA N ANTES BOWIE CLARK o are personally known r haslhave produced �o is/are personalty known to—meter hasihave produced as identification. N/A as identiftcation. l Notary Public Notary Public Commission No.GG 308696 Commission.No. GG 308696 Daphne Clark Daphne Clark Name of Notary typed,printed or stamped Name of Notary typed,printed o{ _ ed DAPHNE A.CLARK DAPHNE A.CI ARK ° Commission#GG 308696 r VFS commisslon#GG 308696 aExpires June 27,2023 Expires June 27,2022 FOFP .or 00WWThru9udgetNctaryServlces *�O �� , 04-26-21-0260-00000-0740 1 Pasco County Property Appraiser http://search.pascopa.com/pareel.aspx?parcel=2126040260000000740 Parcel ID 04-26-21-0260-00000-0740 (Card: 1 of 1) Classification 00000-Vacant Mailing Address Property Value LINKS AT CALUSA SPRINGS LLC Ag Land $0 2301 LUCIEN WAY STE 260 Land $25,025 MAITLAND, FL 32751 Building $0 Extra Features $0 Physical Address 6880 SHELBY LYNN WAY, Just Value $25,025 ZEPHYRHILLS, FL 33542 Assessed (Non-School Amendment 1) $25,025 Legal Descri tt� ion (First 200 characters) See Plat for this Non-School Taxable Value $25,025 School District Taxable Value $25,025 Subdivision LINKS AT CALUSA SPRINGS PB 81 PG 074 LOT 74 Jurisdiction CITY OF ZEPHYRHILLS Land Detail (Card: 1 of 1) Line ;Use 'Code ;Description Zoning Units ;Type_ 'Price iConditionValue . 1 10100V i CP1-1 SFR ! OPUD 5,500.00 SF I $6.50 0.70 $25,025 Additional Land Information _._____._-.._._....._.._.......-----_._--.........._....._...____.___.._......... _._......._.__ ,Acres I _Tax Area _ FEMA Code __._...__-__..._..._._ _ Neighborhood Code(s) -_------- 0.13 30ZH -- LKCS Building Information (Card: 1 of 1) Unimproved Parcel Extra Features (Card: 1 of 1) _------__. Line Code ;Description Year Units :Value No Extra Features Sales History Previous Owner: UNITED CAPITAL FUNDING CORP Month/Year Book/Page _ iType _ 1DOR Code (Condition Amount 10/2019 9987 / 0218 - j Warranty Deed 05 Vacant $2,760,000 - _._. -- 04/2016 ' - ._ ... I -- ...._._. . 9350 / 2262 1 Certificate of Title 12 Vacant $0 --...-. _.-__. -----..__ 12/2011 86391 3248 i Warranty Deed 05 ! Vacant $0 11/2011 1 8627 / 0126 Warranty Deed 12 Vacant I $0 -- -------- - ---- .�_......_.. - -- -.-..------ - 05/2008 ! 7848 / 0427 Quit Claim Deed I i Vacant $0 05/2008 7836 / 1714 Certificate of Title ! i Vacant 1 of 1 10/25/2020, 10:47 PM STATE COPY FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: KH02127 Palmera(TAM) Builder Name: K Hovnanian Homes Street: 6880 Shelby Lynn Way Permit Office: City of Zephyrhills City,State,Zip: FL, 33542 Permit Number: Owner: Jurisdiction: Design Location: FL,Tampa County: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(1908.1 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1636.60 ft2 b.Frame-Wood,Adjacent R=11.0 271.56 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 4 d. N/A R= ft2 5. Is this a worst case? Yes 10.Ceiling Types (2127.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 2127.00 ft2 6. Conditioned floor area above grade(ft2) 2127 b.N/A R= ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 11.Ducts R ft2 7. Windows(174.3 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 273 a. U-Factor: Dbl,U=0.34 118.12 ft2 SHGC: SHGC=0.23 b. U-Factor: Dbl,U=0.63 40.00 ft2 12.Cooling systems kBtu/hr Efficiency" SHGC: SHGC=0.32 a.Central Unit 33.1 SEER:15.00 c. U-Factor: Dbl,U=0.34 16.19 ft2 SHGC: SHGC=0.29 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 32.6 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 3.295 ft. Area Weighted Average SHGC: 0.266 14.Hot water systems 8. Floor Types (2127.0 sqft.) Insulation Area a. Electric Cap:50 gallons a.Slab-On-Grade Edge Insulation R=0.0 2127.00 ft2 b. Conservation features EF:0.950 b.N/A R= ft2 None c.N/A R= ft2 15.Credits Pstat Glass/Floor Area: 0.082 Total Proposed Modified Loads: 65.69 PASS Total Baseline Loads: 66.16 I hereby certify that the plans and specifications covered by Review of the plans and O AjIE S7,q�� " this calculation are in compliance with the Florida Energy specifications covered by this ,� __ ,. •Off, Code. calculation indicates compliance with the Florida Energy Code. PREPARED BY: .�/�/.R/e� Before construction is completed wl� �, DATE: this building will be inspected for compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance Florida Statutes. - with the Florida Energy Code. OWNER/AGENT:- SARAH RIVE'RA BUILDING OFFICIAL: DATE: 11/12/2020 DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). 9/30/2020 11:11 AM EnergyGauge®USA 6.0.02(Rev.1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 1 of 4 DESCRIPTION:LOT 74, PLOT PLAN (NOT A SURVEY) LINKS AT CALUSA SPRINGS, N AS RECORDED IN PLAT BOOK 81, II BASIS OF BEARINGS: PAGES 74-79,OF THE PUBLIC RECORDS OF PASCO COUNTY,FLORIDA. THE CIL OF RiW OF SHELBY LYNN WAY BEARS M THE PROPERTY DESCRIBED HEREON N.02°03'37"E.PER PLAT. rn IS LOCATED IN FLOOD ZONE W PER FLOOD INSURANCE RATE MAP _ NUMBER 12101C 0289F,EFFECTIVE DATE SEPTEMBER 26,2014,COMMUNITY No.120235 PANEL 0289 F. I I I I I I LOT 75 I o . I I LO�6� O 1 11 1 q I S.87 56 23 E. 110.00 LO }I 25.2o.. 5'SideSetback I o I i szr 14.80' _ Q ¢ O 15.0a'�1 O Lo O PADUE-Proposdd .i Slab on Grade I O Z Q Lo I Wal Con hOmn LOT 74 j z I—= 25.20' 1zo' Proposed $�— !� co LU Entry a I- w II _ Q J �' 25.2D' I " " ProposedHDuse O 7.J' �o y j M I 12o' PL-Patera AsplD A O I (� m C'M ! Garage-RIGHT O I M WI O Proposed Lowest Floor I O =I w 8o I�a7>`°$� Elev=1a5.20'per I °O ~ En Z o. IN y I N y A` Approved Grading Plan. ^I i N I �� O i 70.00' a a i cd 25.20' 70.e' 5'SideSetback 14.8D' N.87056'23"W. 110.00, �I IUi I LOT 73 j LEGEND: C< 0FFNWI—S qw= NaNAEdD]sN.- 6AoaBJYAREFENCE NME$$DTHEIM1NSENUrEDI FRR$•F01119 RALRGAebP9n: CcWRJE (�°GLmAAJED —E-H EPAMEA50.5500.4n0N GN'G3ETe.ENNON PoEER ImPE=XN310ENEI]Y P0.YETHYIFIE r5•midmaFANNa qPE CIX•CEArt9®roRi1FRNEC0PD9 m•UENIIFY LMIN PA9P•PFR Pf4NWID NDRYAt](ftAN rm0•CGWaXIIYDEVELtlHENT Ie=U919aJUUEWEbd P6'PRGPERnIdE DISnN. 15=W0NME RC=P0.YNMi G6WDE CH=wltlm IS•L]ffNb®bURrEYDR IRI'RADIAL m=CwORdEr NEG=NAtdFA9niDGP10E RAD=RADNb mF=mUm UNNFFME NN=YAroI tE RCP.REIN(M[EDCDNCREIEPIPE ' [ID•[ONCIIGHTPDLE (Mq=NpLRIDW. PEG•REGwTER® i®IAEfN qPE WAVD=NdViHANEMGW P/N•MCNTLFWAY CUNC°NNCNE]E VERIYMDAi1M 19B9 (51=5U car=arvaFTAvrA =tunaXx DEaDEnc sEc°s— anoN G•[Bn9aWE=D VENOTT ANNI9H LW4•TDW DEPMUr£EAJENEM Nib.NDTTDSCNE -RANGa E ® =WATERNETER DdAE•DIUNPLEANDACCEbs OR=DFFlWI Po:CD105 9R=N9'SEi1R0NR0D FADURItteNEd 'WATERVN.VE ONE'DNINAGEA'OINGRESS£GflE55 P�FU T"R SN-0�SEINAl.ND19N1e J91] �•nRE Hi➢RRNL EA9ELelr LE•FFNAIEADZbE gN/ATEdWNAGE SRt'EEr PARxFRRAlON NAL D]U=ORAINAGEMm UINIY NPUa1CUgl1YEASFAIENr SWJIME9i RN1DAWATe! � •HUad TACK SET azvAnon PAGP=q:RMPR04ID GPADWGRAN �wDHUGFMFMD19iPoc} - E➢tHCENARdNENTAlPRD1ECTIDN PAGiDP wPeiAWRDVEO GRNNNG 1@l•iBA]NIRPAYGFN[MAAAN •UTH eET wsvGvoPlw.�oRoucx — TYP.•Ngcu ��{( [PPnT Fe=MTBWK 1AelE=anon PFDDPNNAGE }'l.MeiYPCIE F9Ai=FAS@AENi q=PtlNt0FLN1ER9EC1bN W[AE55£GRESb EASeAFM m CGNPAEJENGNWElrt pC.pGINTGFdMVANRE LLE=U1111V FAS&EM iP=FGPm NNigPE P6•PCIMKCWPoIINDCIIRI£ WC•YdiNE55C0RYER yCT'=FIEV.(PAGP) PA•iCFPJM]NDNRW,UJ]91] FCP=FF101ANENTCUNIRtt PdM NCEL•VhlW000N9ERVAnDN �. ryNF55G116nWISEND1E01 FRC=gyNi OF REIN..1RVE FASENQITeNE iNJ.FDIBC] PDB=PqM OFRECINMNe YTA9.=N£rW0CNN9ERVAnGN RK=Fgem PMNaU410NNA6 GGC•PpXr DFCWNENCBIBIi SEIeACX11NE FAF.WF.CL.E.'RORmAGPNEMU F101=PWIM`EMIiEFERENCFMGNUNENr --a FPEFNYA11a]gbHCdAlI55mN iL5=PP0FE5g0NALUNbbURVEYDR YABE=WALL WDSGWEA'meUFFEA � fAN9BNAn0NEA9ENEM PSN=PPDFE590NKSMVEYtlid NAPPER FAseAENT a SOD AND CONCRETE CALCS Drainage Total Sod Area in Flow 6•i Total Lot Area in Square Feel t Total RNV Sod Total Conc.Walk Arrow cSquare Feet t (Includes dghtal-way area between Square Feet t Square Feel 2 property[au end hack of Curb) Sidewalks&Gutters per approved N PAVING,GRADING AND DRAINAGE PLAN-A. a 5500 2026 NIA 285 Datum Conversion I A/C Pad Percent Proposed Lot NGVD 1929-0.84'= (NAVD 1988). Total Conc.Driveway Total Conc.Apron TotalquRNV Walk Lot I IIIIII IIIII II II I III III III I IIIIII I IIIIII I IIIII IIIII I III IIIII II II IIIIIIII -m Square Grading Type ul ll(I Square Feel d: Square Fe al t Square Feel t Coverage VERTICAL DATUM NOTE: w. Feel t 9 (PAGP) THE ELEVATIONS SHOWN HEREON -.291 N/A N/A 9 47% Bm ARE REFERENCED TO NGVD 1929. m1e zzozataa 19 m This Sketch Prepared For : K.Hovnanian Homes N REVISIONS Di illy signed a Description Date Own. Ck'd Order No. �� R. frob r COCA�� y Cott R D o ,b ler o a RoRma te: 2020.10.20 Engineering&Surveying Corporation a LAND 8:28:25 -04'00' 8515 Palm River Road Tampa,Florida 33619 ° (813)621-7841 (813)664-1832(fax) on si Drawn:Ds 10-15-20 Client No:2018 SCOTT R. FOWLER SIGNATURE vrwvv,Iesc.com L.B.#3913 a o Checked: FLORIDA REGISTERED LAND SURVEYOR NO. 5185 +, Original No.: 22024439 ICLrrent No.:22024439 Survey Date: N/A Sec.: 4 Two.: 26 S Rge.: 21 E