Loading...
HomeMy WebLinkAbout20-1086 � - D r r City of Zephyrhills M ER 5335 Eighth Street - Zephyrhills, FL 33542 BNR-001086-2020 Phone: (813)780-0020 Fax: (813)780-0021 Issue Date: 12/15/2020 Permit Type: Building New (Residential) YRroperty Number. Sfreet;Address.. 04 26 21 0120 00000 0380 6382 Bradford Woods Drive „Permitlnformation X Contactor Info "mation-° Name: PULTE HOME COMPANY LLC Permit Type:Building New(Residential) Contractor: PULTE HOME COMPANY Class of Work:SFR Construct LLC Address: 2662 Falkenburg S Rd Building Valuation:$127,176.00 RIVERVIEW,FL 33578 Electrical Valuation:$5,689.00 Phone: (813)964-5182 Mechanical Valuation:$4,745.00 Plumbing Valuation:$5,147.00 I }4 Total Valuation:$142,757.00 1 Total Fees:$14,109.86 I Ol Amount Paid:$14,109.86 Date Paid:12/15/2020 8:07:56AM Project,DescriptIon,- CONSTRUCT SINGLE FAMILY 2,972 SQ FT-OAKS OF PASCO Application Fees." Building Permit Fee $665.88 Address Fee $30.00 Public Safety Impact Fee-Police $254.00 Irrigation 3/4 Meter(Calc) $473.78 3/4 Water Meter Fee(Calc) $473.78 Sewer Connection Residential Fee $2,090.00 Mechanical Permit Fee $63.72 SIF 1 percent Fee $83.28 Building Plan Review Fee $332.94 Driveway Fee $45.00 Mechanical Plan Review Fee $31.86 Electrical Permit Fee $68.44 Plumbing Plan Review Fee $32.87 Public Safety Impact Fee-Admin $26.35 Water Connection Residential Fee $1,010.00 School Impact Fee $8,328.00 Electrical Plan Review Fee $34.22 Plumbing Permit Fee $65.74 REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each subsequent reinspection. Notice: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permit required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner:Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications add fee Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. C SI NATURE PE IT OFFICE PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER INVOICE1111 1 • ' CITY OF ' BILLING.CONTACT P JODY SALTER PULTE HOME COMPANY LLC 2662'FALKENBURG S RD RIVERVIEW, FL 33578 . INVOICE NUMBER INVOICE DATE INVOICE DUE DATE. INVOICE STATUS. INVOICE DESCRIPTION INV-00002032 12/07/202.0 1.2/07/2020 Invoiced,_Past,Due NONE REFERENCE NUMBER FEE NAME TOTAL . B.NR-001086-2020 3/4 Water Meter Fee(Calc) $473.78 Address Fee $30.00 , Building Permit Fee $665.88 Building Plan.Review.Fee -$332.94- Driveway.Fee $45.00 . Electrical Permit Fee $68.44 Electrical Plan Review Fee .$34.22 Irrigation 3/4 Meter(Calc) $473.78 Mechanical Permit Fee . $63.72 Mechanical Plan Review Fee $3t86 Plumbing Permit Fee, $65.74 Plumbing Plan Review Fee .$32.87 Public Safety Impact Fee-Admin $26.35 Public Safety Impact Fee.-Police $254.00 School Impact Feb $8,328:00 Sewer Connection Residential Fee: $2,090.00 SIF 1 percent Fee $83.28 Water Connection Residential Fee $1,010.00 6382'Bradford Woods Drive Zephyrhills, FLORIDA 33542 SUB TOTAL . $14,109.86 REMITTANCE INFORMATION TOTAL $14,109.86 City of Zephyrhills 4 5335 Sth:Street Zephyrhills, FL 33542 December_08,2020 5335 8th Street,Zephyrhills,FL 33542 Page.I of 1 .. VI Ly V1 Z-VP1 1y111111J r G111 nL nNNm,auvl l ,�^ •�-•��-���, Building Department late Received Phone Contact for Permittin rr rr r-e e�-i-C71717 )wner's Name P�LI�t � D(1�L CD IVY A.1)t. I✓�G Owner Phone Number )wner`s Address 2bU2 S' Fa-l4nbu!� 0/ iJer�'f L Owner Phone Number 'ee Simple Titleholder Name / Owner Phone Number 'ee Simple Titleholder Address I A IOB ADDRESS ( �82� ( ODGr�S �e/ !'����5� G 3 LOT# IN >UBDIVISION 01v%S0 M00 PARCEL ID# (/! a�Ll' -Al 0/;Z0 -D 30L (OBTAINED FROM PROPERTY TAX NOTICE) NORK PROPOSED M NEW CONSTR R ADD/ALT l� SIGN = DEMOLISH INSTALL REPAIR IROPOSED USE ® SFR 0 COMM [ OTHER TYPE OF CONSTRUCTION 1 BLOCK 0 FRAME t^_J STEEL = )ESCRIPTION OF WORK >7 GV "(/n fi^uG�i n lCGLr`Y1 r l 3UILDING:SIZE � �PLTSQFOOTAGE�' HEIGHT 1 =- BUILDING $ Dd VALUATION OF TOTAL CONSTRUCTION .=ELECTRICAL $� , AMP SERVICE = PRPR-OGRESS ENEERGY W.R.E.C. (L� ► ✓� �✓LL� Ln�r l,. =PLUMBING $ =MECHANICAL $ ` ///i/� ,� VALUATION OF MECHANICAL INSTALLATION =GAS = ROOFING 0 SPECIALTY = OTHER =INISHED FLOOR ELEVATIONS 6?1,3 /^ / FLOOD ZONE AREA =YES NO BUILDER COMPANY SIGNATURE ,/ REGISTERED Y/ N FEE CURREN/}/1 Y//N_ Address ����5� n6 r� ;VN1e,ofrt+3�� ` License# tZia(Y a5- ELECTRICIAN COMPANY cJkGdA SIGNATURE y REGISTERED Y/ N FEE CURREN Y/ !� N Address / / , �/ ` License# ?e<�J PLUMBER COMPANY SIGNATURE REGISTERED Y/ N FEE CURREK Address : 3133��3 r ��Gvr/�IGYY�,Fl,3 78� License# C e,l ya_7a_7 MECHANICAL COMPANY SIGNATURE REGISTERED Y/ N FEE CURREN Y/N �h11� d5La1,FL 3 eP(v License# 3 2� Address / OTHER COMPANY �"L A"CA�79�`G SIGNATURE REGISTERED Y/ N FEE CURREN Y/N /Ig3� iv/n IJr Di?` icl7 1=Z,3 Address i License# RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed; Sanitary Facilities&1 dumpster;Site Work Permit for subdivisions/large projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction. Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. -PROPERTY SURVEY required for all NEW construction. Directions: Fill out application completely. Owner&Contractor sign back of application, notarized If over$2500,a Notice of Commencement is required. (A/C upgrades over$7500) *" Agent(for the contractor)or-Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy.of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage) Driveways-Not over Counter if on public roadways..needs ROW V IJ-/UV-VVLV Ully UT Lepnyrniiis t'erma Hppucauon rax-o io-tou-uut I Building Department Date Received Phone Contact for Permitting ( Owner's Name , ° (i(j7�/ ���� Owner Phone Number �3' ' , Owner's Address , 01 % G Owner Phone Number .Fee Simple Titleholder Name Owner Phone Number Fee Simple Titleholder Address / 2 �^ JOB ADDRESS �Jvv, f OGl'S G _ `�� � �L �J LOT# i SUBDIVISION `. � PARCEL ID# D '�, (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED e NEW CONSTR B ADD/ALT SIGN Q DEMOLISH INSTALL REPAIR PROPOSED USE. SFR Q Comm OTHER I TIV D Z) TYPE OF CONSTRUCTION BLOCK 0 FRAME STEEL DESCRIPTION OF WORK S/��G2�/ Irn �• 7 �j �!(J BUILDING SIZE I o!X _7 D, I SQ FOOTAGE oS% !4j HEIGHT =BUILDING $ VALUATION OF TOTAL CONSTRUCTION =ELECTRICAL $ AMP SERVICE PROGRESS ENERGY Q W.R.E.C. =PLUMBING $ =MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION =GAS ROOFING Q SPECIALTY OTHER FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA DYES NO BUILDER COMPANY IS SIGNATURE REGISTERED Y/N FEE CURREN Y/N Address License# ELECTRICIAN COMPANY SIGNATURE REGISTERED Y/N FEE CURREN Address License# PLUMBER COMPANY SIGNATURE REGISTERED Y/N FEE CURREN Y/N Address License# 'MECHANICAL COMPANY SIGNATURE REGISTERED Y/N FEE CURREN Y/N Address License# OTHER COMPANY SIGNATURE, REGISTERED Y/N FEE CURREN Y/N � Address License# —�� 11621 .adaaaaa.aaasaai aaaaaaaaaaa aaa_aI[ aa.1aaa41 # aaaaaaaaaaaa1gaVltaIaaaaI RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date.Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed,. Sanitary Facilities&1 dumpster;Site Work Permit for subdivisions/large projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction. Minimum ten(10)working days after submittal date.Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance :SIGN PERMIT Attach(2)sets of Engineered Plans. ****PROPERTY SURVEY required for all NEW construction. Directions: Fill out application completely. Owner&Contractor sign back of application, notarized If over$2500,a Notice of.Commencement is required.(A/C.upgrades over$7500) ** ..Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy.of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage) Driveways-Not over Counter if on public roadways..needs ROW Building Department NOTICE OF DEED RESTRICTIONS:The undersigned understands that this permit may be subject to"deed"restrictions"which may be more restrictive than County regulations.The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES:If the owner has hired a contractor or contractors to undertake work,they may be required to be licensed in accordance with state and local regulations. If the contractor,is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work,they are advised to contact the Pasco County Building Inspection Division—Lic$nsing Section at 727-847-8009. Furthermore, if the owner has hired a contractor or contractors,he is advised to have the contractor(s)sign portions of the"contractor Block"of this application for which they will be responsible. If you,as the owner sign as the contractor,that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings,change of use in existing buildings,or expansion of existing buildings,as specified in Pasco County Ordinance number 89-07 and 90-07,as amended.The undersigned also understands,that such fees,as may be due,will be identified at the time of permitting.It is further understood that=Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a"certificate of occupancy"or final power release. If the project does not involve a certificate of occupancy or final power release,the fees must be paid prior to permit issuance.Furthermore,if Pasco County Water_/Sewer Impact fees are due,they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713,Florida Statutes,as amended): If valuation of work is$2,500.00 or more, I certify that I,the applicant, have been provided with a copy of the"Florida Construction Lien Law—Homeowner's Protection Guide"prepared by the Florida Department of Agriculture and Consumer Affairs.If the applicant is someone other than the"owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner"prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction,zoning and land development.Application is hereby made to obtain a permit to do work and installation as indicated.I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction,County and City codes,zoning regulations,and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work,and that it is my responsibility to identify what actions I must take to be in compliance.Such agencies include but are not limited to: - Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands, WaterAlVastewater Treatment. - Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. - Army Corps of Engineers-Seawalls, Docks, Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. - US Environmental Protection Agency-Asbestos abatement. - Federal Aviation Authority-Runways. I understand that the following restrictions apply to the use of fill: - Use of fill is not allowed in Flood Zone W" unless expressly permitted. - If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume" will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. - If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction, I certify that fill will be used only to fill the area within the stem wall. - If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill, an engineered drainage plan is required. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work,plumbing,signs,wells,pools,air conditioning,gas,or other installations not specifically included in the application.A permit issued shall be construed to be a license to proceed with,the work and not as authority to violate,cancel,alter,or set aside any provisions of the technical codes,nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans,construction or violations of any codes.Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance,or if work authorized by the permit is suspended or abandoned for a period of six(6)months after the time the work is commenced.An extension may be requested,in writing,from the Building Official for a period not to exceed ninety(90)days and will demonstrate justifiable cause for the extension. If work ceases for ninety(90)consecutive days,the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF.",COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU IN1TE O OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR TTORNEY BEFORE RECORDINO .. ENCEMENT. FLORIDA JURAT(F.S. 117.03) OWNER OR AGENT - CONTRACTOR Subscribed and savor to or affirme ore me,this Sub cr'bed ands ornA affirm )-be 'me this iDND1�ADZO by � SjLF.Z- /�by Who is/are personally known to me or has/have produced Who is/are personal ly.kriown to me or has/have produced as identification. E: as identification. a otary Public LJ lx,��6&,Z_Notary ,, Public Corm ion No. 6F � .J�S - Corn 1No. �` S �� N me of Notary typed,printed or stamped Name of Notary typed,printed or stamped PATRICIA BURCHETT x° y p MY COMMISSION#GG365171 PATRICIA BURCHETT EXPIRES:AUG 13,2023 r°1r..,.y�o MY COMMISSION#GG365171 Bonded through 1 st State Insurance p EXPIRES:AUG 13,2023 °� Bonded through 1st State Insurance PLOT PLAN DESCRIPTION:(AS FURNISHED) LOT 38, OAKS OF PASCO AS .RECORDED .IN PLAT BOOK 80, PAGE(S) 113-118, OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. ON LOT CALCULATIONS LOT = 5,750 SQ. FT. LIVING AREA = 2,162 SQ. FT. GARAGE = 482 SQ. FT. ENTRY = 34 SQ. FT. LANAI 260 SQ. FT. PATIO = 0 SQ. FT. DRIVEWAY = 328 SQ. FT. A/C PAD = 9 SQ. FT. WALKWAY = 44 SQ. FT. IMPERVIOUS = 58% = 3319 SQ. FT. a SOD = 2,431 SQ. FT, v OFF LOT CALCULATIONS RIGHT OF WAY = 400. SQ. FT. z DRIVE APRON = 57 SQ. FT. V. _ 30, PUBLIC S/W = 250 SQ. FT. GRAPHIC SCALE SOD 93 SQ. FT. TOTALS 0 15 30 AREA = 6,150 SQ. FT. DRIVEWAY = 385 SQ. FT. SIDEWALK = 294 SQ. FT. SOD = 2,524 SQ. FT. U 2 f d �Q O4Q a y Vs 6 OO O� 2� OLL p0 O O OW \��W OW O I L W 3 ^S82'S3'12'E 22 O \o)N I LL o J t---20.00• $g. O " o S82.53'12„ \ o h o 126s E 115.00' \9Oa, sass O�_¢ 1 ¢�� Y DO co a 00 I o M Pw o o^"i QQ W o ..,.o..'I:_��:,:rso•Li m¢� 1-1 V7 WCL Wl _Z o � a z • wO �Wa o p 03 1= Z 20.5' _0 80.00' 0o w g CU � 70.0' I Z Ibg� N82•53P12 w `o 14.s vpi PREPARED FOR: 1 115.00' I I 5 BUILDING SETBACKS FRONT: 20' REAR: 10' SIDE: 5' SIDE STREET: 15' LEGEND: NOTES: — BUILDING SETBACK LINE PI POINT OF INTERSECTION PC POINT OF CURVATURE 1. PROPOSED ELEVATIONS SHOWN HEREON ARE BASED - - - CENTERLINE PT POINT of TANGENCY ON THE APPROVED.ENGINEERING PLANS PREPARED _ - RIGHT OF WAY LINE RP RADIUS POINT BY CORNELISON ENGINEERING & DESIGN INC. PRC POINT OF REVERSE CURVATURE 2. ELEVATIONS ARE BASED ON NAVD 1988 PROPOSED ELEVATION PCP PERMANENT CONTROL POINT . DATUM. TYP TYPICAL PROPOSED DRAINAGE FLOW CS CONCRETE SLAB THIS PLOT PLAN IS INTENDED FOR PERMITTING PURPOSES CONCRETE (C) CALCULATED(P) PER PLAT ONLY. THIS IS NOT INTENDED FOR THE CONSTRUCTION OF A/C AIR CONDITIONER PB PLAT BOOK THE PROPOSED STRUCTURE. THE CONTRACTOR AND/OR PGS PAGES OWNER ARE REQUIRED TO VERIFY ALL SETBACKS, BUILDING S/W SIDEWALK SO. FT. SQUARE FEET DIMENSIONS, AND LAYOUT SHOWN HEREON PRIOR TO ANY F:E.M.A. FEDERAL EMERGENCY MANAGEMENT AGENCY CONSTRUCTION. _ F.I.R.M. FLOOD INSURANCE RATE MAP NAVD NORTH AMERICAN VERTICAL DATUM THIS IS NOT A SURVEY DE SSE DRAINAGE SEWEERE EASEMENT THIS IS A PLOT PLAN.ONLY UE UTILITY EASEMENT. FLOOD NOTE: I HAVE EXAMINED THE F.I.R.M. MAP NO. 12101CO289F SURVEYOR NOTES: DATED 09/26/2014 AND FOUND THE SUBJECT PROPERTY APPEARS TO LIE 1. THE SURVEYOR HAS NOT ABSTRACTED :THE PARTIALLY IN ZONE'X'.&'AE". ZONE"X', AREAS DETERMINED TO BE LAND SHOWN HEREON FOR EASEMENTS; RIGHT OUTSIDE�THE 0.2%ANNUAL CHANCE FLOODPLAIN. ZONE'AE', AREAS DETERMINED TO BE SPECIAL FLOOD HAZARD AREAS SUBJECT TO OF WAY, RESTRICTIONS OF RECORD WHICH INUNDATION,BY THE 1%ANNUAL CHANCE FLOOD EVENT, BASE FLOOD MAY AFFECT THE,TITLE OR USE OF THE LAND. ELEVATIONS DETERMINED TO BE 88.5'. THE SURVEYOR MAKES NO GUARANTEES AS TO THE ABOVE INFORMATION. PLEASE CONTACT THE 2. NO UNDERGROUND IMPROVEMENTS HAVE BEEN LOCAL F.E.M.A. AGENT FOR VERIFICATION. LOCATED EXCEPT AS SHOWN. BEARING BASIS: BEARINGS SHOWN HEREON ARE BASED ON THE CENTERLINE OF A5M 3. NOT VALID WITHOUT THE AUTHENTIC BRADFORD WOODS BEING 1407-a6'48"E, PER PLAT. ELECTRONIC SIGNATURE AND THE AUTHENTIC ELECTRONIC SEAL OF A FLORIDA LICENSED REVISED: A M E R I CA N SURVEYOR AND MAPPER. -(FIELD DATE:) SURVEY 1 N G °°",";°°° 1' = 30 FEET �w+a ee e I Digitally signed by James W Boleman SCALE: '.�e:.H, DN:c L!S,st=Florida,l=0dando, $c MAPPING INC. io=AMERICAN SURVEYING&MAPPING, APPROVED BY: JB = Gv ' °s 1 .. •INC,cn=James WBoleman, CERTIFICATION OF AUTHORIZATION NUMBER 63#6393 or .a& r email=Jholeman@asmcorporate.cam FOR 3191 MAGUIRE BOULEVARD, SUITE 200 +� —Date:2020.11.02009s:24-0s00• 191105 LOT 38 ��'"�'::;_ �� Adobe Acrobat version:11.023 THE JOB NO. ORLANDO, FLORIDA 32803 ��nnvm FIRM (407) 426-7979 DRAWN BY- RMB PLOT PLAN 10-29-2020 JSO WWW.AMERICANSURVE)INGANDMAPPING.COM JAMES W. BOLEMAN PSM# 6485 DATE CITY OF-.ZEP YRHILLS "City of Pure Water" 5335 Eighth Street•Zephyrhills,Florida 33542-4312 (813)780-0000_-Fax (813) 780-0005 GENE WHITFIELD June 13,.2018 Mayor Mr.David Waronker CITY COUNCIL 1420 Celebration Blvd., Suite 200 LANCE A.SMITH Celebration,FL 34747 Council.President Dear Mr.Waronker, KENNETH M.BURGESS,JF- VicePresident City of Zephyrhills Ordinance 1003-08, Section 12, Paragraph 5, provides that planned unit developments (PUD) approved prior to September 30, 1988 are CHARLES E.PROCTOR exempt from paying transportation impact fees unless amended to permit additional development that would:generate traffic. W.ALAN KNIGHT The Silver Oaks PUD was approved on its third and final reading on January 11, JODI WILKESON 1988, and therefore is exempt from paying transportation impact fees as stipulated in Ordinance 100308 provided the original permitted number of dwelling units remains the same.According to Todd Vande Berg, city planneri those numbers within the Silver Oaks PUD have remained constant. STEVEN F.SPINA City Manager Therefore,the Oaks at Pasco is exempt from paying these fees'...A copy of Ordinance 1003-08 is provided for your information.The exemption and credits LORI L.HILLMAN City Clerk,CMc section is located on page 10. MATTHEW E.MAGGARD Sincerely, -City Attorney Steven F, Spina,PhD City Manager cc: Todd Vande Berg, City Planner Bill Burgess,Building Official Matthew E. Maggard, City Attorney New Account:: � RESIDENTIAL COMMERCIAL Name Doing Business As Serv'rc A Mailing Address (if different) Phone Number D �' % E Mail Address(optional) _ For E-Bills Date to Connect Service Dumpster Note:Copy of rental agreement.or lease must be shown if applicant does Ilot own the property, The City of Zephyrhills recognizes that an individual's driver's license number is a unique form of identification that can be utilized to obtain sensitive information regarding that particular individual.However,the City of Zephyrhills must collect Drivers License numbers under certain circumstances in order for the City to be able to properly perform its duties and functions as a municipal corporation and in order to ensure that such duties and functions are performed accurately and efficiently. THE CITY OF ZEPHYRHILLS COLLECTS YOUR DRIVERS LICENSE NUMBER ONLY FOR THE FOLLOWING PURPOSES: CLASSIFICATION OF ACCOUNTS IDENTIFICATION CREDITWORTHINESS OR COLLECTIONS BILLING AND PAYMENTS DATA COLLECTION, RECONCILIATION AND TRACKING NEW UTILITY ACCOUNT APPLICATION POLICE STATEMENTS AND ARRESTS FOR THE VERIFICATION OF IDENTITY Each individual who provides a Drivers License number to the City of Zephyrhills shall be provided with a copy of this notice Signarure Date kr E9, 3D 90 47 J 1 I` X _ d 3 d:;3 d 37 I �- � 139 ! 4q : J 41 d �( �92,1,1 FF= .1.86� F=91.61 1:3 ; FF..-�31.121 d g1.1'6 FF=9 i. 6 sQ t 90 d J I A i i d , I a r — 77 78 --74 RETAININr- D Q r t t Single .Family Dwelling Plan Review Comments 1. F.F.E. shall be a minimum of 8" above the road elevation and an engineered site plan. 2! Lots shall be.graded to comply with R401.3:'of the.F.B.C. . .5: Compaction test required if 24"or more of fill dirt is brought in at any one.place. 4: Tie in surveyrequired before.pouring concrete. 5; Driveways require.a R.O.W. use permit: All 4 sides of driveway thru the sidewalk shall have expansion material. 6. All setbacks shall be met. 1. All,property markers shall be uncovered,and marked at time of first inspection. 8: All A.D.A.requirerrients shall be met: .. 9.. No electric,plumbing;mechanical,or framing shall.be covered without an inspection and approval first. 10. All Garages,shall comply with section R302.6 of the F.B.C. (Fire Separation).. 11. Appliances shall not be installed in a location where subject to mechanical damage unless protected. approved barriers. M3034 of the F:B:C 12. Water heaters shall comply with section P607.3 of the F.B:C.. 13.-Foundation suppbrts for A/C units shall.be raised at least 3"above finislie_d grade. M1308:1 14:Return air in all bedrooms. F.B:C. M1620.4 1.5. Smoke detectors are to be installed in accordance with R3111-of the F.B.C. 16:All glazing reguirenients are to be i ' accordance with R308.4 of the F.B.C: 17. All means of egress are to be'in accordance with R311 of the F.B.C. 18. "Green gypsum.board" shall not be used as a backer in showers or tubs. R702.4.2 F.B.C. 10. Combination-type AFCI breakers are required at all locations requiring an AFCI type breaker. 20. Carbon monoxide.alarms will be required in new construction that uses fossil-burning heating or appliances or an attached garage. They shall be installed in accordance with the F.B.C. 21. All plumbing,mechanical, and electrical shall be separate from unit.to unit: This includes all underground plumbing and electric. 22: All 2016 N.E.C. Codes will be enforced. 23. Tamper- Resistant Receptacles in accordance with 406.11 of the.2016 N..E.0 24. In accordance with the Land Development Code, lots.shall.be sodded before final at least 10 feet around the structure. 25; R403.5.3Hot water pipe insulation Insulation for hot water'pipe with a minimum thermal resistance (R-value) of R-3 shall.be applied to the following: Piping �1;inch (19.1 mm)and larger in. nominal diameter. Piping serving more than one dwelling unit: Piping located outside'the conditioned spate.. Piping from the water heater to a distribution manifold:. Piping located under a floor slab. Buried in piping. Supply and return piping in recirculation systems other than demand recirculation systems: 25:Blower.door test shall be provided before C,O. 26. A copy ofthe enerizy cacls shall be with yermit at all times: 27.. CoPV ohUal insulation:report-shall be provided with permit before final 28. No fence, pool or screen enclosure :is issued with:this permit F.F.E.-Finished Floor Elevation F.B.C-Florida Building Code 6 h Edition R.O.W.-Right of Way A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code(2016)