HomeMy WebLinkAbout20-1088 City of Zephyrhills °'spERMITNU.MBER �'
5335 Eighth Street {
Zephyrhills, FL 33542 ELCMISC-0010 -2020
Phone: (813)780-0020 Fax: (813)780-0021 Issue Date: 11/18/2020
f=,
Permit Type: Electric Service Replacement/Misc
Property Nlumber � ,R StreetYAddress
05 26 21 0080 00500 0030 35942 Saddle Palm Way
'Inforination` Permitanforination ` Contractor Info�matton
Name: MICHAEL OZOROWSKI Permit Type:Electric Service Replacement/M Contractor:TESLA ENERGY% ,
Class of Work:Add/Alter Residential OPERATIONS INC
Address: 35942 Saddle Palm Way Building Valuation:$0.00
ZEPHYRHILLS,FL 33542 Electrical Valuation:$17,950.00
Phone: (813)516-5487 Mechanical Valuation:
Plumbing Valuation: In /
Total Valuation:$17,950.00 ` 1 ✓�/
Total Fees:$194.63
Amount Paid:$194.63
Date Paid:11/18/2020 8:24:33AM
Project Description"
INSTALLATION TESTA POWERWALLS(2)
Appltcation Fees ry4 ; 4 = y t ;.
Electrical Permit Fee $129.75 Electrical Plan Review Fee $64.88 R
REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c)the
local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or
first reinspection,whichever is greater,for each subsequent reinspection.
Notice: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that
may be found in the public records of this county, and there may be additional permit required from other governmental
entities such as water management, state agencies or federal agencies.
"Warning to owner:Your failure to record a notice of commencement may result in your paying twice for
improvements to your property. If you intend to obtain financing,consult with your lender or an attorney
before recording your notice of commencement."
Complete Plans,Specifications add fee Must Accompany Application.All work shall be performed in
accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O.
NO OCCUPANCY BEFORE C.O.
or CONTRACTOR SIGNATUR PE IT OFFICE
PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION
CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED
PROTECT CARD FROM WEATHER
T Smwaw S; L '"w
Limited Power of Attorney
Date:07/23/2020
I
I
RE: PERMIT AUTHORIZATION
i
Lorraine Mullins
Dear Sir or Madam: Colin Winslow
Sydney Williams
This letter is to verify that Andrew Arsudo is an authorized representative of Tesla
Energy Operations and is authorized to pull any and all permits, business licenses,and other project j
related documents as needed. Please don't hesitate to call me if you have any questions.
Sincerely,
j
I
Nicholas Armstrong _
Responsible Managing Employee, License#EC13006226
Regional Vice President j
ALL-PURPOSE CERTIFICATE OF ACKNOWLEDGEMENT
i
A notary public or other officer completing this certificate verifies only the identity of the individual who j
signed the document,to which this certificate is attached, and not the truthfulness,accuracy or validity
of that document.
State of Florida
County of Hillsborough
On 07/23/2020 before me, Nicholas Armstrong personally,appeared,who proved to me on the basis
of satisfactory evidence to be the person who name is subscribed to the within instrument and
acknowledged to me that he executed the same in his authorized capacity,and that by his signature on
the instrument the person,or entity upon behalf of which the person acted,executed the instrument.
I certify under penalty of perjury under the law of the State of Florida that the foregoing paragraph is
true and cor-re_ctt..
Signatureof Notary
�vr"'p, Nolan•Fuollr_;;late of Porno-
`' �. ASNII r N
My Commission GG 149324
E xpres 1010,02021
c 5 L ii '}.w�s�kF"%'Ss'`�/. l�i'1,n/\!`,�i,•'•.n:/'ti/'�....
813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021
~- Building Department
~ Date Received I 813-460-7640
Phone Contact for Permitting
1 1 1 1 1 1 1 1 1 1 1 1 1
owner's Name Owner Phone Number 8135165487
Owner's Address 35942 Saddle Palm Way Owner Phone Number N/A
Fee Simple Titleholder Name I N/A Owner Phone Number N/A
_ Fee Simple Titleholder Address I N/A
JOB ADDRESS 35942 Saddle Palm Way,Zephyrhills, FL 33541 LOT#
SUBDIVISION Silverado Ranch PARCEL ID#1 05-26-21-0080-00500-0030
(OBTAINED FROM PROPERTY TAX NOTICE)
WORK PROPOSED e NEW CONSTR B ADD/ALT = SIGN 0 0 DEMOLISH
INSTALL REPAIR
PROPOSED USE = SFR COMM = OTHER I TESLA POWERWALLS
TYPE OF CONSTRUCTION = BLOCK 0 FRAME = STEEL =
DESCRIPTION OF WORK Installation of(2)Tesla Powerwalls
BUILDING SIZE SQ FOOTAGE HEIGHT
BUILDING $ 17,950.00 VALUATION OF TOTAL CONSTRUCTION
=ELECTRICAL $ AMP SERVICE VP/OGRESS ENERGY Q W.R.E.C.
=PLUMBING 0 G/
u c
=MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION
=GAS = ROOFING Q SPECIALTY = OTHER
FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES NO IIIYYYfffAI
TESLA ENERGY OPERATIONS,INC.
BUILDER COMPANY
SIGNATURE 01(" REGIST Y/ N FEE CURREN Y/N
Address 5012 Joanne Kearney Blvd Tampa,FL 336 License# N/A EC1300622s
ELECTRICIAN COMPANY
SIGNATURE REGISTERED I Y/ N FEE CURREN Y/N
Address 1 License#
PLUMBER COMPANY N/A
SIGNATURE REGISTERED I Y/ N FEE CURREN Y/N
0
z
0
Address N/A License# I N/A
E
MECHANICAL COMPANY N/A
0
SIGNATURE REGISTERED I Y/ N FEE CURREN YIN
o ,
m Address N/A License# I N/A
r�
C� OTHER COMPANY N/A
SIGNATURE REGISTERED I Y/ N FEE CURREN Y/N
Q
o Address N/A License# N/A
N
r � rrrrtrtrl � I � II � � tI � IIIrfl � tt � r � � � � t � rl � I � if � IIIIIrrtlrrlltil � IrII1
RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction,
Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed,
Sanitary Facilities&1 dumpster;Site Work Permit for subdivisions/large projects
COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction.
NMinimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed,
Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance
tO SIGN PERMIT Attach(2)sets of Engineered Plans.
****PROPERTY SURVEY required for all NEW construction.
m
Directions:
v' Fill out application completely.
o Owner&Contractor sign back of application,notarized
m
LL If over$2500,a Notice of Commencement is required. (A/C upgrades over$7500)
rn " Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same
m OVER THE COUNTER PERMITTING (copy of contract required)
o Reroofs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage)
Driveways-Not over Counter if on public roadways..needs ROWsyrt.
DocVerify ID:5D189590-F6BD4932-B8C6-6982779ASESA Page 2 of 3 1 26982779A5E6A I ,III rL�r,l II
www.docverify.com -- -- - — &'r
NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed"restrictions"
which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any
applicable deed restrictions.
UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or
contractors to undertake work,they may be required to be licensed in accordance with state and local regulations. If the
contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation
under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the
intended work,they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847-
8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign
portions of the "contractor Block"of this application for which they will be responsible. If you, as the owner sign as the
contractor,that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco
County.
TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands
that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings,change of
use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and
90-07,as amended. The undersigned also understands,that such fees, as may be due,will be identified at the time of
permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to
receiving a"certificate of occupancy"or final power release. If the project does not involve a certificate of occupancy or
final power release,the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact
fees are due,they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances.
CONSTRUCTION LIEN LAW(Chapter 713,Florida Statutes,as amended): If valuation of work is$2,500.00 or more,I
certify that 1, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's
Protection Guide"prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone
other than the"owner",I certify that I have obtained a copy of the above described document and promise in good faith to
deliver it to the"owner"prior to commencement.
CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work
will be done in compliance with all applicable laws regulating construction,zoning and land development. Application is
hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has
commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating
construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also
certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is
my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to:
Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive
Lands,Water/Wastewater Treatment.
Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering
Watercourses.
Army Corps of Engineers-Seawalls,Docks,Navigable Waterways.
Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment,
Septic Tanks.
- US Environmental Protection Agency-Asbestos abatement.
Federal Aviation Authority-Runways.
I understand that the following restrictions apply to the use of fill:
Use of fill is not allowed in Flood Zone W"unless expressly permitted.
If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a
"compensating volume"will be submitted at time of permitting which is prepared by a professional engineer
licensed by the State of Florida.
- If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall
construction,I certify that fill will be used only to fill the area within the stem wall.
- If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent
properties. If use of fill is found to adversely affect adjacent properties,the owner may be cited for violating
the conditions of the building permit issued under the attached permit application, for lots less than one (1) r
acre which are elevated by fill,an engineered drainage plan is required.
z If I am the AGENT FOR THE OWNER,I promise in good faith to inform the owner of the permitting conditions set forth in
this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work,
plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A
permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel,alter,or
set aside any provisions of the technical codes,nor shall issuance of a permit prevent the Building Official from thereafter
requiring a correction of errors in plans,construction or violations of any codes. Every permit issued shall become invalid
unless the work authorized by such permit is commenced within six months of permit issuance,or if work authorized by
the permit is suspended or abandoned for a period of six(6)months after the time the work is commenced. An extension
may be requested, in writing,from the Building Official for a period not to exceed ninety(90)days and will demonstrate
o justifiable cause for the extension. If work ceases for ninety(90)consecutive days,the job is considered abandoned.
o WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR
PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING,CONSULT
a WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
FLORIDAJURAT(F
a IlAichael.Ozotowsby l'%✓/Awsd
O. _ERO._AfE i_ �p CONTRACTO
cru Subscribed and sworn to(or affirmed)before me this Subscribed an o t or a�rir ed before e i
11/n3YJm�by Michael O7orn-Sky by Y 5'Ij�(�y 14L�AJ]A�
Who is/are personally known to me or has/have produced Who islare persona y known tome or has/have produced
m DL as identification. as identification.
m
rn
c
m p� Notary Public Notary Public
lommission No. HH41285Angela Presto
cam' Angela Presto Qommission#HH 41285
o Name of Notary typled:,print Notary Public-State of Florida ted or stamped
My Commission Expires Sep 10,2024
Nary 6omo:mbi
www.docv ID:5D189590•F6BD-0932-BBC6-6982779ASE6A -� ,III
Page 3 of 3 1 36982779A5E6A
www.docvenfy.com -- ---- -- --
INSTR#2020187603 OR BK 10210 PG 3625 Page 1 of 3
11/05/2020 09:03 AM Rcpt,2223486 Rec:27.00 IDS-0.00 IT:0.00
Nikki Alvarez-Sowles,Esq.,Pasco County Clerk&Comptroller
Permit No. Parcel lD No 05-25.21-0080-00500.0030 '
NOTICE OF COMMENCEMENT
state of Florida Cean:y of Pasco
THE UNDERSIGNED nereoy goes nobee that improvement mil be made to cer—real property,and In accordance wlh Chapter 713.Flonda Sletutes,
the falowinginft—ton spmv dedm1hs11.0 of Commencement
1. Desenptionofrimpahy:Parcel ldemificatior Ne.tinJi.eom —noto snuTiicnp wncavmwma a 4ssn PP'ISP 11 uocxs
Street Address: 35942 Saddle Palm Way.Zephyrhills.FL 33541
2. Geneml Desonpbon of Improvement
Installation of Testa Powerwall(s)
3 Owner Information or Lessee In`ennation dthe Lessee contracted to'the improwement*
Birth—I hznrnvreky
Name
35S42 waddle Paln tVay larinvi is FI
Address City sate
Interest m Property Homeowner
Name o`Fee Simple TNeholder N/A
(Ifdlffemnt from Owner listed above)
N/A N/A
Address Tesla Energy Operafiuns,Inc. City State
4. Canlracnr.
Name
5012 Jeanne Kearney SIA T,nma ,-
Address City Sale
Coub—1 s Telephone No. 813-460-7640
S. Surely N/A
Name
N/A NIA
Address City Sate
Amount of Bond.$NIA -e ephoneI N'N
5 Lender. NIA
Name
N/A HfA.
Add.. City Sate
Lendel's Telephone No.: NIA
7. Persons with the State on Florida des gnated by the owner 4pun wrwm no,kes or otter documents may be serval as prcaded by
Section 713.13(1)(a)(7p.rdrida Statutes.
WA
Name
N!A N/A. NIA
Address City Sale
Telephone Number of Designated Person WA
6 Inaddi:iontoldrrtselrineownerdesanales WA of NfA
Z to rew ve a copy of the Ueno(s Notice as provided in Seaim 713.'3(I)(b).Florida Satves.
be
Telephone Number of Person or Ent ty Designated by Owner. Silverade Ranch
2
9. Expiration dale of Notice of Cmnmenwmenl(the expiragon Jain nay nut be bebre the wmpluliun ur cmatrucUun end final paymm�t lu 9re
contractor,but will be one year from the date or recording uNess a ditherenl date I speonedY
WARNING TO OWNER:ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT
ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER713,PAR-1,SECTION713.-3,FLORIOA STATUTES.AND CAN
RESUL-IN YOJR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE
RECORDED AND POSTED ON THE JOB SITE BE=ORE THE FIRST INSPECTION.IF YOU INTEND TO 087.AIN FINANCING,CONSULT `
W TH YOUR-ENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT.
Under penalty of perjury,I declare that I have read the forego ng not ce of commencement and that the fads sated:herein are true to the best
of my knowledge and tvlef.
STATE OF FLORIDA l+ticiinei O orpwiity
COUNTY OF PASCO-SEMINOLE �
RSignature of Owncror Lessee,crOwncr's or Lessee's Autho—cl
Of1—/Direclpr/Pamun1Manager
Homeowner
S;mAl ry s TU.,OYco
NThe foregoing mst—wit was acanowledged befp-e me this_day 01 11/n3n02F9_by
� _ Owner (type of audwariry,e.g.,officer,Nuslee.attorney in hoop for
IN (name of pony an stv;na
mPersonal y<nown[I03 Prpducetl Identification® � Notary Slgnalu�e A �.
om Type of ldenu0caticn Produced DL Name(Pnni) Angela Presto �•
Angela Presto
Commission tt HH 41285
g Notary Public-State of Florida
My Commission Expires Sep 10.2024
DpcVedly ID:50189590-F6B0-4932•B8C6.6982779A5E6A Page 1.13 16982779A5E6A ,III&py pp'�` ,I II
www.dp�vetty—ft OaT9t�i!l
u
TSSLFi
Powerwall Purchase& Home Improvement Agreement _
This "Agreement",is between you and the-Tesla entity ("Tesla", "we" "us" or 'bur") identified below. It consist s.of..(1) the
below PriceSheet'and (2)the attached terms & conditions, and is effective on the date'you'sign the agreement.
F Powerwall Price Sheet -
Your information. =
Lauren Ozorowsky
35942 Saddle Palm Way
Zephyrhills, FL 33541
81.35165487
I Tesla_entity
_
Tesla Energy Operations Inc. of 3500 Deer Creek Road, Palo Alto, CA, 94304
888-765-2489
FL EC13006226/CCC1331559
i Powerwall Energy Storage System, Installation Services, and Purchase Price.
Powerwall -
2 x Powerwall(s) `,t $13,000:00.
1 x Backup Gateway(s) $1,000.00
Powerwall Installation $3,000.00
System Price $1.7,000.00
Taxes $950.00
Contract Price - $17,950.00
Credit for Ordet�Payment ($100.00)
Amount Due $17,850.00
i Schedule of Payments_
Paid at Order $100.00
Due Within Five (5) Days of Inspection $17,850.00.
The schedule of progress payments must specifically.•describe each phase of work, including the type and amount of work••
or services scheduled to be supplied in each•-phase,-along with the amount of each proposed progress payment:-IT IS `•,
AGAINST THE LAW FOR A CONTRACTOR TO COLLECT PAYMENT FOR WORK NOT YET COMPLETED, OR FOR
MATERIALS NOT YET DELIVERED. HOWEVER,.A CONTRACTOR MAY REQUIRE A DOWNPAYMENT.
The pricing in this Agreement is valid for 30 days after 10/25/2020. If you don't sign this Agreement and return it to us on
or prior to 30 days after 10/25/2020,,Tesla reserves the right tolreject this Agreement unless you agree"to our then,current
pricing.
You,the buyer, may cancel this transaction at any time prior to midnight of the third business day after the date
of this transaction. See the attached notice of cancellation form for an explanation of this right.
Powerwall Purchase&Home Improvement,Agreement •
V2.0,7/17/2020
Tesla,Inc. ,
4283182
Customer's Initials: L O
If you are financing your System.through one of our financing partners, the timing and amount of your payments (and any
applicable interest accrued) will be subject�'to the terms and conditions of your agreement with.your financier.`If,your
financier fails to make payment.on,your behalf;:or your financing is terminated by you or:,-'your financier, you will remain
obligated to make�,payment under the terms of'this Agreement.
FAPP:roximate Installation Start Date
7-90 days from the•.date of this Agreement
Approximate Completion.Date
7=90.days from the date of this Agreement
Your signature TeslaJ Inc.
Lauren Ozorowsky
Name: Lauren Ozorowsky
Date: 10/26/2020 4:18:49 AM +00:00
Name:Carl Peterson
Title:Senior Director, Regidential Energy
You are entitled to a completely'flled'in copy,of this Agreement, signed by both you and Tesla, before,any-work may be
started.
1
i
Powerwall Purchase&Home Improvement Agreement
V2.0,7/17/2020
Tesla,Inc. ! t
4283182-
T = S Ln
March 26, 2019
Tesla Powerwall Hardware Compliance Letter
To whom it may concern:
The installation manual for the Tesla Powerwall was reviewed for mounting considerations. Based
on the weight of the unit"and the attachment layout of the mounting bracket, it was determined that
the following fasteners should be used:
Wood Studs:
(4)-'/4'wood screws with w/2-1/2" minimum embedment
Metal Studs:
(3)—'/4" sheet metal screws at each corner w/ 1-1/2" minimum penetration (25 ga stud minimum)
(1)— W sheet metal screws at each corner w/ 1-1/2" minimum penetration (18 ga stud and thicker)
Concrete/CMU:
Schedule "A"for clear height less than 2'-9"
FASTENER SCHEDULE "A'.+
MANUF MODEL DIAMETER EMBEDr,04T
SI,%APSON T1TEN Y"¢ 1Y"
HILTI KWIK—CONK H + Yn"4 1!Z"
POWERS TAPPER + Y"0 1Y"
Schedule "B"for clear height greater than 2'-9" and/or if the governing jurisdiction requires fastener
ESR report*.
FASTENER SCHEDULE "B"*
I,'1 NUF MODEL DIAMETER EMBEDMENT ESR;"
SI&1PS0N TITEN HD %"0 23;" ESR-2713 (CONCRETE) & ESR-1056 (CMU)
HILT] KH—EZ Wo 1%" ESR-3027 (CONCRETE) & ESR-3056 (CMU)
POWERS WEDGEBOLT + %"0 lY" ESR-2526 (CONCRETE) & ESR-1678 (CMU)
E R
.0
F
ICH S R O
GOR� -�
Exp: m
0 CIVIL p
a -a
No. 2 23�j�
TESLA MOTORS, INC 3500 Deer Creek. Rd. Palo Alto, CA 94304 p 650.681.5000 f 650.681.5200
r
T S� S Ln
Tesla Standard Photovoltaic Systems - Electrical Qualification Certification Letter
Tesla is offering standard solar photovoltaic(PV) systems to simplify the ordering and install
experience, lower costs, and make solar accessible to more Americans. All applicable electrical
code/requirements have been incorporated into the decision-making process for these
standardized offerings. The material selection and installation practice of these PV systems are
fixed. Product datasheets and UL listings provided are exclusively used for this standardized PV
product and provide information on PV module and PV inverter used. The repeatability of this
standardized product offering ensures compliance with the NEC. Please refer to the design
documentation with all the code compliant wiring options that can be utilized.
Prior to commencement of installation, Tesla's Electrician/Contractor shall verify existing service
conductor and electrical panel to be in suitable condition for interconnection, not exhibiting
previous arc or physical damage on insulation of service conductors and panel busbar which
may affect ampacity and its ability to establish proper connection between the PV inverter and
utility grid. The interconnection is performed ensuring that any one of the methods discussed in
NEC section 705.12 is followed.
The system can be interconnected to the utility grid in two ways:
1. Supply side connection as covered by NEC Section 230.82(6) and NEC Section
705.12(A), The sum of the ratings of all PV over-current protection device connected
shall not exceed the rating of the service.
2. Load side connection as covered by NEC article 705.12(D)(2). The section specifies
that interconnection is permitted, provided one of the methods of interconnection to
busbar are followed. Approved load side interconnection methods are listed in the
following:
- Feeder in accordance with NEC 705.12(D)(2)(1)
- Load side tap in accordance with NEC 705.12(D)(2)(2)
- Breaker tie-in on busbar in accordance with NEC 705.12(D)(2)(3)
I certify that installation of Tesla standard photovoltaic (PV) systems with interconnection to an
electrical service meets the criteria outlined in NEC article 690, 705 and related articles in NEC
and is therefore permitted by code. The PV system design described in the design document,
when properly installed and maintained, meets the minimum recommended practices
established by the Florida Solar Energy Center(FSEC) certification and those requirements set
forth by the most recent edition of Florida Building code(FBC). This approval does not imply
endorsement or warranty of the mo;yiV& lain erter.
���P�p,NO 'SF/r���i
♦ '9
•
Chidanand Sekar, P.E. ♦ Cj;• v�GENSF••'•.9 ��.�
Electrical Engineer, Tesla : No 83534
csekar(cDtesla.com *;
Direct. 614 256 5685 Exr 4*60 z1jr
Licensed in Florida 9'; STATE OF :I-'Z
%i O •. R Q:•_���
Chid Digitally signed �����••• O R �?\
,',by Chid Sekar �� O N A
Date:.2019.06.05
S e ka r, / 16:24:48-07'00'
ELECTRICAL?ONLY