e
City of Zephyrhills PERMIT NUMBER
5335 Eighth Street
Zephyrhills, FL 33542 BNR-001103-2020
f Phone: 813 780-0020
y Fax: (813) 780-0021 Issue Date: 12/22I2020
Permit Type: Building New (Residential)
Property Number Street Address
2821 Lytton Hall Drive
Owner Information Perrnit Information Contractor Information
Name: LENNAR HOMES LLC Permit Type:Building New(Residential) Contractor: LENNAR HOMES LLC
Class of Work:SFR Construct
Address: 4600 W Cypress St 200 Building Valuation:$256,391.40
TAMPA,FL 33607 Electrical Valuation:$38,458.71
Phone: (813)574-5700 Mechanical Valuation:$17,947.40
Plumbing Valuation:$25,639.14
Total Valuation:$338,436.65
Total Fees:$19,505.25
Amount Paid:$19,505.25
Date Paid:12/22/2020 8:35:31AM
P.roj FRONT ription
CONSTRUCT SINGLE FAMILY 2,276 SQ FT HIDDEN RIVER
Application Fees
Mechanical Permit Fee $129.74 3/4 Water Meter Fee(Calc) $473.78
Water Connection Residential Fee $1,010.00 SIF 1 percent Fee $83.28
Plumbing Permit Fee $168.20 Electrical Plan Review Fee $116.14
Address Fee $30.00 Plumbing Plan Review Fee $84.10
Mechanical Plan Review Fee $64.87 Transportation Impact Fee-City $36.32
Public Safety Impact Fee-Admin $26.35 School Impact Fee $8,328.00
Transportation Impact Fee $3,595.68 Building Permit Fee $1,311.96
Driveway Fee $45.00 Public Safety Impact Fee-Police $254.00
Building Plan Review Fee $655.98 Sewer Connection Residential Fee $2,090.00
Electrical Permit Fee $232.29 Park Impact Fee-Single Familyrrownhome $769.56
REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c)the
local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or
first reinspection,whichever is greater,for each subsequent reinspection.
Notice: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that
may be found in the public records of this county, and there may be additional permit required from other governmental
entities such as water management, state agencies or federal agencies.
"Warning to owner:Your failure to record a notice of commencement may result in your paying twice for
improvements to your property. If you intend to obtain financing,consult with your lender or an attorney
before recording your notice of commencement."
Complete Plans, Specifications add fee Must Accompany Application.All work shall be performed in
accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O.
NO OCCUPANCY BEFORE C.O.
I
'SdNTRACTOK SIGNATURE PE 7MIT OFFICE
PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION
CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED
PROTECT CARD FROM WEATHER
PASCO COUNTY Receipt Date: 04/07/2021
BUILDING CONSTRUCTION SERVICES Receipt Number: 2033876
PASCA....., 6181 Citizens Drive
COUNTY' FLo. �Ay Suite 230
Omr,,SrAm. 61111UNT 15LACS New Port Richey, FL 34654
727-847-8126 1 :5 q q,,7 7-2--
iNOT A PERMIT "
Paid By -Check# CC Auth'ft Cashier ID Workstation
Check 01501436 MLARNOLD BCCCP47L
Fee Description Amount Paid
Impact Fee Residential Solid Waste Single Family 50.58
8
Total Payments: $50-.58
Pavor Address Phone
LENNAR HOMES
Comments:
25-26-21-0110-00000-1726
2821 LYTTON HALL DR
While you will be paying your bill With Pasco County Building Construction Services,the full amount of the credit card or e;cheEk fees,,NOT shown above,Is collected by First
611iing payment services:
myreportslreportallproductionIPASCOICustomer Receipt vlfr pt Print Date: 04/01/2021 Page 1 of 1
INVOICE1111 1
FOR OF
BILLING CONTACT
STEVE SMITH
LENNAR HOMES LLC
4600 W CYPRESS ST
TAMPA, FL 33607
INVOICE NUMBER INVOICE DATE INVOICE DUE DATE INVOICE STATUS INVOICE DESCRIPTION
INV-00002033 12/08/2020 12/08/2020 Due NONE
REFERENCE NUMBER FEE NAME TOTAL
BNR-001103-2020 3/4 Water Meter Fee(Calc) $473.78
Address Fee $30.00
Building Permit Fee $1,311.96
Building Plan Review Fee $655.98
Driveway Fee $45.00
Electrical Permit Fee $232.29
Electrical Plan Review Fee $116.14
Mechanical Permit Fee $129.74
Mechanical Plan Review Fee $64.87
Park Impact Fee-Single Family/Townhome $769.56
Plumbing Permit Fee $168.20
Plumbing Plan Review Fee $84.10
Public Safety Impact Fee-Admin $26.35
Public Safety Impact Fee-Police $254.00
School Impact Fee $8,328.00
Sewer Connection Residential Fee $2,090.00
SIF 1 percent Fee $83.28
Transportation Impact Fee $3,595.68
Transportation Impact Fee-City $36.32
Water Connection Residential Fee $1,010.00
2821 Lytton Hall Drive Zephyrhills, FLORIDA 33540 SUB TOTAL $19,505.25
REMITTANCE INFORMATION TOTAL $19,505.25
City of Zephyrhills
5335 8th Street
Zephyrhills, FL 33542
December 08,2020 5335 8th Street,Zephyrhills,FL 33542 Page 1 of 1
813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021
Building Department
Date Received U
Phone Contact for Permitting 813 363 __ 2891
—
Owner's Name Lennar Homes,LLC Owner Phone Number r813.574.5700
Owner's Address 1
4600 W.Cypress St.Ste.200,Tampa,FL 33607 Owner Phone Number
Fee Simple Titleholder Name I N/A Owner Phone Number
Fee Simple Titleholder Address N/A
JOB ADDRESS 2821 Lytton Hall Drive LOT# 0172
SUBDIVISION Hidden River Phase 2 PARCEL ID# 25-26-21-0110-00000-1720
,�� (OBTAINED FROM PROPERTY TAX NOTICE)
WORK PROPOSED II./ II NEW CONSTR e ADD/ALT 0 SIGN Q DEMOLISH
INSTALL REPAIR
PROPOSED USE SFR 0 COMM OTHER
TYPE OF CONSTRUCTION BLOCK Q FRAME STEEL 0
DESCRIPTION OF WORK Single Family Residence/Pool/Screen Enclosure/Fence
BUILDING SIZE U/R SF 2276 SQ FOOTAGE 1817 HEIGHT 1 Story
�—OBUILDING $ $256,391.40 VALUATION OF TOTAL CONSTRUCTION
ELECTRICAL $ $38,458.71 AMP SERVICE ® PROGRESS ENERGY Q W.R.E.C.
r
PLUMBING $ $25,639.141 W 11 n j
iMECHANICAL $ $17,947.40 VALUATION OF MECHANICAL INSTALLATION
„ •=GAS W1 ROOFING Q SPECIALTY 0 OTHER
FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA E]YES Do
BUILDER COMPANY I Lennar Homes,LLC
SIGNATURE REGISTERED Y/ N FEE CURREN Y/N
Address 4600 W.Cypress St.Ste.200,Tampa,F 33607 License# I CGC1518166
ELECTRICIAN COMPANY Kdrnonson Electric, Inc.
SIGNATURE GISTERED Y/ N FEE CURREN
Address 1034 Skipper Road,Tampa, FL 3361 License# EC13005408
PLUMBER COMPANY Bayonet Plumbing, Heating &AC, Inc
SIGNATURE REGISTERED I Y/ N I FEE CURREN I Y/N
Address P.O. Box 5308, Bayonet, FL 34674-5 8 License# I CFC042998
MECHANICAL COMPANY I Bayonet Plumbing, Heating &AC, Inc
SIGNATURE REGISTERED Y/ N FEE CURREN I Y/N
Address P.O. Box 5308, Bayonet, FL 34674 308 License# I CAC058062
OTHER COMPANY C Sterling Quality Roofing, Inc
SIGNATURE REGISTERED Y/ I FEE CURREN Y/N
Address 4211 Shoal Line Blvd, Spring Hill, FL 34607 License# 1 CCC057991
1111111111111111111111111111111111111111111111111111111111111111111
RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction,
Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed,
Sanitary Facilities&1 dumpster;Site Work Permit for subdivisions/large projects
COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction.
Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed,
Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance
SIGN PERMIT Attach(2)sets of Engineered Plans.
****PROPERTY SURVEY required for all NEW construction.
Directions:
Fill out application completely.
Owner&Contractor sign back,of application,notarized
If over$2500,a Notice of Commencement is required. (A/C upgrades over$7500)
** Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same
OVER THE COUNTER PERMITTING (copy of contract required)
Reroofs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage)
Driveways-Not over Counter if on public roadways..needs ROW
NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed" restrictions"
which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any
applicable deed restrictions.
UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or
contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the
contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation
under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the
intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847-
8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign
portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the
contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco
County.
TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands
that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of
use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and
90-07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of
permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to
receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or
final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact
fees are due,they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances.
CONSTRUCTION LIEN LAW(Chapter 713, Florida Statutes, as amended): If valuation of work is$2,500.00 or more, I
certify that I, the applicant, .have been provided with a copy of the "Florida Construction Lien Law—Homeowner's
Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone
other than the"owner", I certify that I have obtained a copy of the above described document and promise in good faith to
deliver it to the"owner"prior to commencement.
CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work
will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is
hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has
commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating
construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also
certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is
my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to:
- Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive
Lands, Water/Wastewater Treatment.
- Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering
Watercourses.
- Army Corps of Engineers-Seawalls, Docks, Navigable Waterways.
- Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment,
Septic Tanks.
- US Environmental Protection Agency-Asbestos abatement.
- Federal Aviation Authority-Runways.
I understand that the following restrictions apply to the use of fill:
- Use of fill is not allowed in Flood Zone"V" unless expressly permitted.
- If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a
"compensating volume" will be submitted at time of permitting which is prepared by a professional engineer
licensed by the State of Florida.
- If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall
construction, I certify that fill will be used only to fill the area within the stem wall.
- If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent
properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating
the conditions of the building permit issued under the attached permit application, for lots less than one (1)
acre which are elevated by fill, an engineered drainage plan is required.
If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in
this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work,
plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A
permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or
set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter
requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid
unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by
the permit is suspended or abandoned for a period of six(6) months after the time the work is commenced. An extension
may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate
justifiable cause for the extension. If work ceases for ninety(90)consecutive days, the job is considered abandoned.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR
PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT
WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR E OF COMMENCEMENT.
FLORIDA JURAT-(F.S. 1-17.03)-F
---- -- _ ,- - -- -- - - --- --- -
OWNER OR AGENT CONTRACTOR
Subscribed and sworn to( r affi a before me this Subscribed and sworn to(or affirmed)before me this
LO—VGI—LU by Ashlee 2e-oc,-20 by Ashlee Callahan
Who is/are personally known to me or Who is/are personally known to me or
as identification. as identification.
Notary Public Notary Public
Commission No. HH 000460 Commission No. HH 000460
Elissa M.Holleran Elissa M.Holleran
Name of Notary typed,printed or stamped Name of Notary typed,printed or stamped
---------------------
VY ELISSAM.HOLLERAN ELISSAM.HOLLERAN
Commission#HH 000460 a Commission#HH 000460
Expires June 6,2024 Explres June 6,2024
9„tQ Bonded Ttw Troy Fain Insurance 800 386 70f0 Bonded Tlw Troy Fain Insurance 000.M7019
r
Single .Family Dwelling .
Plan Review Comments
1. FXX shall be a minimum of 8" above the road elevation and an engineered site plan.
2! Lots shall be graded to comply with R401.3 of the F:B.C.
3. Compaction test required if 24" or more of fill dirt is brought in at any one-place.
4: Tie in survey required before pouring concrete.
5. Driveways'require a R.O.M. use permit: All 4 sides of driveway thru the sidewalk shall have
expansion material.
6. All setbacks shall be"met.
7. All property markers shall be uncovered.and marked At time of first inspection.
8: All A.D.A. requirements shall be' met:
9. No electric,plumbing,mechanical"or framing shall be:covered without an inspection and .
approval first.
10: All Garages shall comply with section R302.6 of the F.B.C. (Fire Separation):
11. Appliances shall not be installed in a location where subject to:meclianicai damage unless
protected by approved barriers. M303:4 of the F.B.0
II.Water heaters shall comply with section P607.3 of the F.B*C..
13:Foundation supports for A/C units.-shall be raised at least 3" above finished grade. M1308:1
14. Return air in all bedrooms: F.B.C.: M.16204
15. Smoke detectors are to be.installed iri"accordance with R313.1 of the F.B.C.
16: All"glazing requirements are to be in accordance with R308:4 of the F.B.C:
17. All means of egress are to be in accordance with R311 of the F.&C..
18. "Green gypsum board" shall not be used as a backer in showers or tubs. R702.4:2 F.B.C.
19..Combination-type AFCI breakers are required at all locations requiring an AFCI type breaker. .
20. Carbon monoxide alarms will be required in new construction that.uses fossil-burning heating
- or appliances or an attached garage. They shall be installed in accordance with the F.B.C:
21. All plumbing,mechanical; and electrical shall be separate from unit to unit: This includes,all
underground.plumbing and electric.
22. All 2016 N:E.C. Codes will be enforced:
y
21 Tamper- Resistant Receptacles in accordance with 406.l l of the 2016-N.E:C
24. In accordance with the Land Development Code,lots shall be sodded before final at least 10
feet around the structure.
25. R403.5.3Hot water pipe insulation,
Insulation for hot.water pipe with a minimum thermal resistance(R-value) of R-3 shall be applied to the
following:
Piping-1;inch (19.1 mm)and larger in nominal diameter..
Piping serving more than.one dwelling unit.
Piping located,outside the conditioned space.-
Piping from the water heater to a distribution manifold..
Piping.located under a floor slab.
Buried in piping,.
Supply and return piping in recirculation systems other than demand recirculation systems.
25. Blower door test shall be provided before.
26. A copy of the enemy.cacls shall be with permit at all times.
27.. Cony of riinal insulation'report shall be provided with Permit before fnab
28.No fence,pool or screen enclosure .is issued with this permit
F.F.E.-Finished Floor Elevation
F.B.C- Florida Building Code 6t'Edition
R.O.W..-Right of Way
A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code(2016)
f A r r 4 I FF EL .t a1
rb
s k 1VVVV
` FFFi 7Fl:
�
. 16 t ,
""'PHASE I
"'{ � I r A j r I•t�� � I+ ,� 1 � i / } t R J fr
FF EL+`r
167
S ` f 73,10vj
\ x
\
sty �j� � w''+ ��'1 r f;{{fYr'•,,�`#�fR ,�l � ,� �a ''ft i`t
168
FF EL
169
EL
70 FF EL
r to e{ 73.40 {/ ,� t 6{t��' FFEL ` 17L1.
L
40
•y K. �A� �F Ei.
ti4w 4r` Y 171 73.504
�s�}+,4 {l1�''•'S�,` +}L y����f' FI �� j }: Y �� f,!—CLFF EL
�t}L '}\sli�t '" 1+:+•..' d ) 4 r•t+7..`J.".7 �'a. ° f tr i'£ .
�+��^1�`i VM1�I�it �t -`� 7 .A���r� �t � f i �, t�` ' �( €• r,
174, k�� !
i:•,:F. 51��Pt S,."• `. ? 's� i �}1 r i jr t'•i �, `.
173,
Si^f
'° .
�,>} `1`€}1'4�'14,.fit•k+ .�• ;� � �� �'x '*� ,� R 1`f l� 1 t j v�
t �F
�j °'V
�� t t.;ltt t�,4.�a:• "w'S; 'k.1 v 'h, r l J
a}4`LF.I�'t��ty'+ty'�L.��y51tt.�1..e'.4 '� ,.�•?-�.`- �.,.,�t f 1 l '� ,�" �t!��'�`�
w � �!4�`ta�y,M1�a+'t tt `'•'M1y� t t 6 ^��eq" ��Pk t ✓ �
It} L 'w5 i4rilyy\,,� Lt,it4 ei Y 1r� ,f A
I
155�tyy�l,'' ti"�.5?*. tr
+ sl t�751 1 '1t i y
i
: PASCO COUNTY, FLORIDA
k _ _ Permit No.
/ Date Permitted -— Zd
Builder Name/Owner Name f1 Carr Control#' "
County Parcel No. 2-,5 Z4 Z 1 6.//O dI oe)172 /SubDiv: of e
Address/Locatlan
Classiticatton/Type of Usq
TRANSPORTATION IMPACT FEE Rate: Sq.Ft Unit
Exempt (]l(es E] No How Determined
Impact Fee Amount $,' -57;6 3q• Zone No. TAZ:
SCHOOL IMPACT FEE
Amount (056) Single-Family Detached House Amount $ l/
j I (057) ' Moblle Home
(058) Other Restdentlal
4 123) Collection Fee
Exempt [�Yes. Q No How Determined
PARKS.AND RECREATION FEE-
Land Account Land Credit Land Total
Recreation Account Recreation Credit Recreation Total
Zone TOTAL AMOUNT $° �6
Exempt Yes No Haw Detetmined'&
LIBRARY FEE
Land Account Land Credit Land Total
Facility Account Facility.Credit Facility Total
Exempt ❑Yes 0 No How Determined Total!Amount-_'_�
RESOURCE FEE ERU
TOTAL AMOUNT
Prepared By + Checked By
NO CERTIFICATE,OF,OCCUP.,ANCY WILL BE ISSUEIDOR.FINALINSPECTION
PERFORMED UNTIL THE.TOTAL Amdt kTS LISTED FFAVE
BEEN-PAID AND
RECEIPTEb FOR BY A CENTRAL`PERmirnNO OFFICE•OF.PASCO COUNTY
Aok bAedgement below does not Imply acceptance of oonaurence,but simply Ncelpt 9Fa copyi of.fhle torte,placing the bull g;pennit ownei on notice of thle assessment and tha conditlons of payment for same.
DATE RECEIVED BY
RECEIPT NO. DATE BY
SKETCH ONLY SEC. 25 TWP. 26 S, RNG. 21 E.
PLOT PLAN NOT A BOUNDARY SURVEY
LOT 172 BEARING BASIS:
HIDDEN RIVER PHASE 2 WEST BOUNDARY OF SUBJECT PLAT BEING N 00'23'02" E
PASCO COUNTY, FLORIDA. DO NOT SCALE THIS PRINT. DIMENSIONS AND
PRELIMINARY DRAWING: NOTES TAKE PREFERENCE.
THIS PLAN IS FOR PERMITTING PURPOSES T ALL DATA SHOWN HEREON BASED ON THE
ONLY, NOT FOR CONSTRUCTION. VERIFY 1� ENGINEERING PLANS OF KIMLEY-HORN AND
ALL DIMENSIONS BEFORE ANY CONSTRUCTION. ASSOCIATES, INC., PROVIDED BY LENNAR HOMES.
LEGEND:
ww� = PROPOSED DRAINAGE FLOW M * = 10' PUBLIC UTILITY EASEMENT
II
(00.00) = PROPOSED GRADE
E-00.00 = EXISTING GRADE
4i
NOTES: a
LOT GRADING TYPE = A V)
PROPOSED PAD ELEVATION =
FRONT SETBACK = 20'
SIDE SETBACK = 10'
REAR SETBACK = 10' y� PCP(P)
RADIUS
51 0�.•'' POINT
a S 6'S.•..
LY 7ON HALL
DRIVE
(72.00') (PRIVATE R/W VARIES)
LOT 171 (TRACT B)
\ ` CZ.
\ o0
�•`�'�� LOT 172
� •� r' `'�ha°' Ado 00 /034,...�
A p rye• ..
F
S.
E
\ as.,J. .................. (FpF7'- sJJ 000:" o ON LOT AREA CALCULATIONS
\ � ffo, LOT =_8031_74-SQ. FT.9i `o° it- LIVING AREA = 1838 SQ. FT.
•'1, c s 6� ENTRY = 32 ---SQ. FT.
\ .tih boo• ^�� GARAGE =__406 ---SQ. FT.
\ R7 LOT 173 COVERED LANAI = 1A---SO. FT.
PATIO =__23 ---SQ. FT.
q�. CONC. DRIVE =__41_0---SQ. FT.
n/ A/C & CONC PAD = 9-----SQ. FT.
"?3�4 (� PRIVATE SIDEWALK = 72 IMPERVIOUS ----SQ. FT.
o0 %
' __\ C90 = 35
ya ___2790 __SQ. FT.
J �< \ rop SOD =--5242 --SQ. FT.
�O \ TRACT "C" OFF LOT AREA CALCULATIONS
y DRAINAGE EASEMENT RIGHT OF WAY =__aq_67_SQ. FT.
\ HIDDEN RIVER PHASE ONE A
\(PLAT BOOK 74, PAGES 101-121) PLAT DRIVE APRON 7_34 SQ. FT.
BOUNDARY PUBLIC SIDEWALK 150 ---SQ. FT.
SOD ---SQ. FT.
?s, TOTALS
\ AREA =__8421_41-SQ. FT.
DRIVEWAY = 54_4SQ. FT.
\ SIDEWALK =__222___SQ. FT.
SOD =__5348 _-SQ. FT.
CURVE RADIUS ARC CHORD BEARING DELTA
PROPOSED:
C90 173.00' 1o7.2z' 105.51' N 50'17'47" W 35'30'35^ LOWEST FLOOR ELEVATIONS:
C9B 63.00' 38.81' 38.20' S 49'51'15" E 35'17'56^ LIVING AREA: 73.65'
I
DESCRIPTION: GARAGE AREA:
ELEVATIONS REFERENCED TO
LOT 172, MAP OR PLAT ENTITLED "HIDDEN RIVER PHASE 2", NATIONAL GEODETIC VERTICAL
AS RECORDED IN PLAT BOOK 079, PAGES 102 THROUGH . DATUM OF 1929. MEAN SEA
110, OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. LEVEL= 00.00 FT.
APPARENT FLOOD HAZARD ZONE: "X" COMMUNITY PANEL NO. 12101 C 0458 F EFFECTIVE DATE: 09 26/2014
Square Feet: 8031.74 f LENNAR HOMES
LEGEND:
(C)= CALCULATED DATA, (D)= DEED DATA, (M)= MEASURED DATA, (P)= PLAT DATA, q= CENTERLINE, A/C= AIR CONDITIONER, B/C= BACK OF CURB, C/S=
CONCRETE SLAB, CH= CHORD, CHB= CHORD BEARING, CLF= CHAIN LINK FENCE, CONC= CONCRETE, COV.= COVERED, E/P= EDGE OF PAVEMENT, ESM'T= EASEMENT,
F/C= FENCE CORNER, FCM= FOUND CONCRETE MONUMENT, FIP= FOUND IRON PIPE, FIR= FOUND IRON ROD, FN&D= FOUND-NAIL & DISK, FPP= FOUND PINCHED
PIPE, LFE= LOWEST FLOOR ELEVATION, MAS.= MASONRY, OR= OFFICIAL RECORD BOOK, PB= PLAT BOOK, PCP= PERMANENT CONTROL POINT, PRM= PERMANENT
REFERENCE MONUMENT, R/W= RIGHT OF WAY, R= RADIUS, SIR=SET 1/2" IRON ROD & CAP No. 4493, SN&D= SET NAIL & DISK No.4493, TBM= TEMPORARY
BENCHMARK U P= UTILITY POLE W F= WOOD FENCE
JOHN R.BEACH&ASSOCIATES, INC. Drawn By:
SMS
SURVEYORS AND MAPPERS
911 WEST ST. PETERSBURG DRIVE Checked By:
ONE OLDSMAR, FLORIDA 34677 JRB
WAY (813) 854-1276 FAX (813) 855-8370 Scale:
1"=30'
NOT VALID WITHOUT ORIGINAL SIGNATURE Date: PLOT PLAN 11/3/20 JBS
AND SEAL OF A FLORIDA LICENSED CC- �A_
SURVEYOR AND MAPPER6"a (I (D
Revisions: S AT D E
JOHN R. B CH
FLORIDA REG. LAND SURVEYOR No. 2984 LB 4493