20-1108
,1 0 � fl City of Zephyrhills °P8RMITMUM88R 5335 Eighth Street Zephyrhills, FL 33542 ELCMISC-001108-2020 Phone: (813)780-0020 Fax: (813)780-0021 Issue Date: 12/03/2020 �1 Permit Type: Electric Service Replacement/Misc Property Number Street Address 24 26 21 0100 00000 0910 3292 Kresterbrook Ln Owner Information Permit Information Contractor Information Name: AARON MCCOMBS Permit Type:Electric Service Replacement/M Contractor: GENESIS ELECTRIC Class of Work:Add/Alter Residential SERVICES Address: 3292 Kresterbrooke Ln Building Valuation:$24,044.00 ZEPHYHRILLS,FL 33542 Electrical Valuation:$3,000.00 Phone: (813)522-2088 Mechanical Valuation: Plumbing Valuation: Total Valuation:$27,044.00 Total Fees:$322.83 14z Amount Paid:$322.83 Date Paid:12/3/2020 2:56:07PM Project Description INSTALLATION ROOF MOUNT SOLAR Application Fees °-7, Electrical Plan Review Fee $27.50 Building Permit Fee $160.22 Plan Review Fee $80.11 Electrical Permit Fee $55.00 REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each subsequent reinspection. Notice: In addition to the requirements of this permit,there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permit required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing, consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications add fee Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. m -eQNZRACT R SIGNATURE PE IT OFFICE PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department Date Received — g ( 813 ) 808 - 0218 Phone Contact for Permittin lasagna# laaaaaaaaaa Owner's Name Aaron Mccombs Owner Phone Number (813) 522-2088 owner's Address 1 3292 Kresterbrooke Lane, Zephyrhills, FL 33540 Owner Phone Number Fee Simple Titleholder Name Owner Phone Number Fee Simple Titleholder Address JOB ADDRESS 3292 Kresterbrooke Lane, Zephyrhills, Florida 33540 LOT# 91 SUBDIVISION HIDDEN RIVER PHASE ONE PARCEL ID# 24-26-21-0100-00000-0910 (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED e NEW CONSTR 8 ADD/ALT SIGN Q 0 DEMOLISH INSTALL REPAIR PROPOSED USE SFR COMM OTHER TYPE OF CONSTRUCTION BLOCK - Q FRAME STEEL DESCRIPTION OF WORK ROOF MOUNTED SOLAR PANEL INSTALL BUILDING ZE SQ FOOTAGE HEIGHT 1 :1 3EX__1r JE�[bra[C yr e € � �C��� 5' €�xi-€9[-Wi i FaFr€3F F 3rX!-3-XTI-€€WI W1 BU ILDING G $ 04 VALUATION OF TOTAL CONSTRUCTION ELECTRICAL $ 3,000 AMP SERVICE 0 PROGRESS ENERGY Q W.R.E.C. OPLUMBING $ =MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION l =GAS ROOFING Q SPECIAL FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA DYES NO BUILDER . COMPANY SIGNATU I REGISTERED Y/N I FEE CURREN Y/N Addrs I License# ELECTR IAN v COMPANY GENESIS ELECTRIC SERVICES LLC. SIGN AT RE REGISTERED Y/N FEE CURREN Y/N A dress 2825 Murray Pass, Odessa FL 33556 License# EC13007122 PLU BER COMPANY SIG ATURE REGISTERED Y/N FEE CURREN Y/N Address License# M HANICAL COMPANY Sl NATURE REGISTERED Y/N FEE CURREN Y/N Address License# OTH COMPANY [Q=SSOLAR SIGNATURE REGISTERED Y/N FEE CURREN Y/N Address 2732 Broadway Center BLVD.Brandon, FL 33510 License# CVC 57002 lllllll##l #all as glass WElEllllllllll131 VIER 1113lll.11l €lll111111 €llllllall RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date.Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster;Site Work Permit for subdivisions/large projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction. Minimum ten(10)working days after submittal date.Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities,&"1'dumpster.,Site Wo_rk.Permit:for.atl new.projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets ****PROPERTY'SURVEY regdi�&d'for-all.NEW;constrLctjon:, Directions: 6 Fill out application completely. = - Owner&Contractor sign back of application,notarized If over$2500,a Notice of Commencement is required.(A/C upgrades over$7500) ** Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage) Driveways-Not over Counter if on public roadways..needs ROW 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department NOTICE OF DEED RESTRICTIONS:The und, igned understands that this permit may be subject to"deed"restrictions'which may be more restrictive than County regulations.The undersigned asses,.es responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES:If the owner has hired a contractor or contractors to undertake work,they may be required to be licensed in accordance with state and local regulations.If the contractor is not licensed as required by law,both the owner and contractor may be cited for a misdemeanor violation under state law.If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work,they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847-8009. Furthermore,if the owner has hired a contractor or contractors,he is advised to have the contractor(s)sign portions of the"contractor Block"of this application for which they will be responsible.If you,as the owner sign as the contractor,that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings,change of use in existing buildings,or expansion of existing buildings,as specified in Pasco County Ordinance number 89-07 and 90-07,as amended.The undersigned also understands,that such fees,as may be due,will be identified at the time of permitting.It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a"certificate of occupancy"or final power release.If the project does not involve a certificate of occupancy or final power release,the fees must be paid prior to permit issuance.Furthermore,if Pasco County Water/Sewer Impact fees are due,they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713,Florida Statutes,as amended):If valuation of work is$2,500.00 or more,I certify that I,the applicant, have been provided with a copy of the"Florida Construction Lien Law—Homeowner's Protection Guide"prepared by the Florida Department of Agriculture and Consumer Affairs.If the applicant is someone other than the"owner',I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner'prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT:I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction,zoning and land development.Application is hereby made to obtain a permit to do work and installation as indicated.I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction,County and City codes,zoning regulations,and land development regulations in the jurisdiction.I also certify that I understand that the regulations of other government agencies may apply to the intended work,and that it is my responsibility to identify what actions I must take to be in compliance.Such agencies include but are not limited to: - Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands,Water/Wastewater Treatment. - Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. - Army Corps of Engineers-Seawalls, Docks, Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. - US Environmental Protection Agency-Asbestos abatement. - Federal Aviation Authority-Runways. I understand that the following restrictions apply to the use of fill: - Use of fill is not allowed in Flood Zone"W unless expressly permitted. - if the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume" will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. - If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction, I certify that fill will be used only to fill the area within the stem wall. - If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill, an engineered drainage plan is required. If I am the AGENT FOR THE OWNER,I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction.I understand that a separate permit may be required for electrical work,plumbing,signs,wells,pools,air conditioning,gas,or other installations not specifically included in the application.A permit issued shall be construed to be a license to proceed with the work and not as authority to violate,cancel,alter,or set aside any provisions of the technical codes,nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans,construction or violations of any codes.Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance,or if work authorized by the permit is suspended or abandoned for a period of six(6)months after the time the work is commenced.An extension may be requested,in writing,from the Building Official for a period not to exceed ninety(90)days and will demonstrate justifiable cause for the extension. If work ceases for ninety(90)consecutive days,the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND OBTAIN FINANCING, CONSULT WITH YOUR LEWDER OR AN ATTORNEY BEFORE RECORDING FLORIDA JURAT(F.S.117.03) � OWNER OR AGENT CONTRACTOR Subscribed and sworn to(or affirmed)before me this Subscribed and sworn to(or affirmed)before me this by 11/18/2020 by Seann Gates Who-is/are personally known to me or has/have produced Who is/are personallyy known to me or has/have produced as identification. DL as identification. Notary Public Notary Public Commission No. commis on NO. GG 959064 Jason S. Monchgesang Name of Notary typed,printed or stamped Name of Notary typed,printed or stamped ,�.o;,,t' JASON S. MONCHGESANG s Notary Public-State of Florida sg = Commission# GG 959064 My Commission Expires February 17, 2024 DocuSign Envelope ID:5E84E687-281D-413C4-8D1E-82AEACB9243E , CONTRACT FOR SALE AND INSTALLATION OF A 7.04 SYSTEM (hereinafter the"System")by and between US Solar Squared,LLC(hereafter"Seller"whose address is below provided)and Aaron Mccombs (hereinafter jointly or severally"Buyer")whose address is 3292 Kresterbrooke Lane Zeph ills Florida 33540 according to the terms and conditions hereafter stated. Buyer understands and agrees that this contract is binding only when accepted by Seller by having its duly authorized company officer or member execute this contract.Buyer further understands and agrees that the full contract price for purchase and installation of the System shall be the following price $27 044.00 unless amended by subsequent agreement of the parties. Buyer further acknowledges and agrees that Buyer is not to give the sales agent presenting me this contract any money or check as the sales agent is an independent contractor and is not authorized to collect money on behalf of Seller. TERMS AND CONDITIONS MECHANIC'SLIENNOTICE: ACCORDING TO FLORIDA'S CONSTRUCTION LIEN LAW (SECTIONS 713.001 - 713.37, FLORIDA STATUTES),THOSE WHO WORK ON YOUR PROPERTY OR PROVIDE MATERIALS AND ARE NOT PAID IN FULL HAVE A RIGHT TO ENFORCE THEIR CLAIM FOR PAYMENT AGAINST YOUR PROPERTY IF YOUR CONTRACTOR OR SUBCONTRACTOR FAILS TO PAY SUBCONTRACTORS, SUBSUBCONTRACTORS, OR MATERIAL SUPPLIERS. THE PEOPLE WHO ARE OWED MONEY MAY LOOK TO YOUR PROPERTY FOR PAYMENT, EVEN IF YOU HAVE ALREADY PAID YOUR CONTRACTOR IN FULL. IF YOU FAIL TO PAY YOUR CONTRACTOR, YOUR CONTRACTOR MAY ALSO HAVE A LIEN ON YOUR PROPERTY. THIS MEANS.IF A LIEN IS FILED YOUR PROPERTY COULD BE SOLD AGAINST YOUR WILL TO PAY FOR LABOR, MATERIALS, OR OTHER SERVICES THAT YOUR CONTRACTOR OR A SUBCONTRACTOR MAY HAVE FAILED TO PAY. TO PROTECT YOURSELF, YOU SHOULD STIPULATE IN THIS CONTRACT THAT BEFORE ANY PAYMENT IS MADE, YOUR CONTRACTOR IS REQUIRED TO PROVIDE YOU WITH A WRITTEN RELEASE OF LIEN FORM ANY PERSON OR COMPANY THAT HAS PROVIDED TO YOU A "NOTICE TO OWNER." FLORIDA'S CONSTRUCTION LIEN LAW IS COMPLEX, AND IT IS RECOMMENDED THAT YOU CONSULT AN ATTORNEY. BUYER'S RIGHT TO CANCEL This is a home solicitation sale,and if you do not want the goods or services,you may cancel this contract by providing written notice to the Seller in person,by telegram,or by mail.This notice must indicate that you do not want the goods or services and must be delivered or postmarked before midnight of the third business day after you sign this contract. If you cancel this contract,the seller may not keep all or part of any cash down payment. Date Buyer signed this contract is: 10/26/2020 _.If Buyer decides to cancel this contract,Buyer will send the cancellation notice to Seller at its address provided below within three business days after this date. By signing below,Buyer agrees to the terms and conditions stated above and on the reverse side of this page. Buyer(s): If r�oare/e�esa�yuse must sign as well). By Aarnn Mrrnmhs By B37904409MBVB... ACCEPTANCE:By signing below,Seller hereby accepts Buyer's offer according to the terms and conditions stated above and on the reverse side. DocuSigned by: US Solar Squared,LLC B 2732 Broadway Center Blvd. Seann Gates,Prest ent Brandon,Florida 33510 2DA494735BBB49A... State License#CVC57002 Date Accepted 10/27/2020 CHAPTER 558 NOTICE OF CLAIM CHAPTER 558, FLORIDA STATUTES, CONTAINS IMPORTANT REQUIREMENTS YOU MUST FOLLOW BEFORE YOU MAY BRING ANY LEGAL ACTION FOR AN ALLEGED CONSTRUCTION DEFECT. SIXTY DAYS BEFORE YOU BRING ANY LEGAL ACTION, YOU MUST DELIVER TO THE OTHER PARTY TO THIS CONTRACT A WRITTEN NOTICE, REFERRING TO CHAPTER 558, OF ANY CONSTRUCTION CONDITIONS YOU ALLEGE ARE DEFECTIVE AND PROVIDE SUCH PERSON THE OPPORTUNITY TO INSPECT THE ALLEGED CONSTRUCTION-DEFECTS AND TO CONSIDER MAKING AN OFFER TO REPAIR OR PAY FOR THE ALLEGED CONSTRUCTION DEFECTS. YOU ARE NOT OBLIGATED TO ACCEPT ANY OFFER WHICH MAY BE MADE. THERE ARE STRICT DEADLINES AND PROCEDURES UNDER THIS FLORIDA LAW WHICH MUST BE MET AND FOLLOWED TO PROTECT YOUR INTERESTS. Installation11.10 Y DocuSign Envelope ID:5E84E687-281D-4BC4-8D1E-82AEACB9243E 1.INCORPORATION:The parties agree that the terms and provisions set forth on the front page are incorporated into this contract by reference. 2.JOB SPECIFICATIONS:The specifications for the System are set forth in the work order attached hereto and incorporated herein by reference. The contract price set forth on the front page shall include i) the purchase of the System described in the work order; ii) the installation of the System by Seller or its subcontractor, and iii) costs of supplies and materials used in the installation of the System. Buyer agrees to be fully responsible for all sales taxes,if any,levied in connection with the purchase and installation of the System.Unless otherwise set forth in this contract, the installation shall occur at the address of Buyer stated in the preamble.It is the obligation of the Buyer to provide Seller or its subcontractor utility services so that Seller may properly install the System. 3.SERVICE AGREEMENT: Buyer agrees that this is not a contract governed under Chapter 672,Florida Statutes, as this is a contract primarily for the installation of the System.Seller is not responsible for securing for Buyer any Federal Tax Credit,State or Power Company rebate,if any. 4.RESTOCKING FEE:Except for instances caused by US Solar Squared,LLC,US Solar Squared,LLC will charge the customer a restocking fee of 15%for any cancellations after the recession period ends. 5.FINANCING:If Buyer does not have the funds readily available to pay the contract price following the installation of the System,Buyer agrees to apply to a financing company to pay the contract price on forms provided by the financing company. Such application shall be undertaken by Buyer independent of Seller whom Buyer agrees is neither Buyer's agent nor the agent of the financing company in connection with any loan application.If Buyer applied for financing in connection with this contract, Buyer understands that Seller will not accept Buyer's offer unless the financing is approved by a duly licensed financing institution in good standing in the State of Florida.If Seller accepts Buyer's offer and thereafter leams that the financing has not been issued,or if issued is then withdrawn by the financing company, Seller may terminate this contract without any liability to Buyer. 6.WARRANTY: Seller agrees,on condition that the full contract price has been paid on completion of the installation of the System,to warrant the operation of the System for one year following its installation.If,during this one year period,the System or any its components should fail to operate in accordance with the manufacturer's specifications,Seller agrees to replace or repair the System at its sole cost and expense, including parts, supplies and labor.US Solar provides a 10 year Workmanship Warranty and a 5 year Roof Penetration Warranty. 7.LIMITATIONS OF WARRANTY:The warranty of repair and replacement given by Seller in paragraph 5 above shall be null and void if Buyer or anyone else shall damage or improperly maintain or operate the System, or should injury or damage be caused the System by fire,rain, freeze, storm (including hurricane)or any other force majeure or act of God.Furthermore,Buyer acknowledges and agrees that the proper maintenance and operation of the System is dependent upon the conditions of proper design,construction and maintenance of Buyer's property and building(and pool if applicable)where the System is to be installed and operated,and that the plumbing and electrical services serving Buyer's property are adequate to maintain and operate the System as intended once installed. If the System fails to operate within the manufacturer's specifications because of the failure of any of these conditions, then the warranty of Seller is null and void. Furthermore, it is specifically agreed that SELLER DOES NOT PROVIDE AN IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE AS TO THE SYSTEM BEING INSTALLED. 8. LIMITATION OF LIABILITY:The exclusive obligation and liability of Seller, and that of its officers,subcontractors,agents and employees, to Buyer for any direct, indirect or consequential damages arising from or related to i) the failure of the System to operate according to the manufacturer's specifications, or ii) damage to the property or building of Buyer due to a defect in the System or to the negligent or improper installation of the System, or iii) for any personal injury (including death) caused Buyer by a defect in the System or its improper or negligent installation is limited to the contract price;and,except to that extent,the Buyer hereby releases,discharges and waives any other claim or demand for damages, injuries or losses of any kind or nature, or any other suit or action that Buyer may or does have against Seller, or any of its officers, employees or agents,based upon a defect in the manufacture, installation or operation of the System, including any claim, demand, suit or action Buyer might or could make or bring for the negligent installation of the System by Seller and its officers, subcontractors, agents and employees. Furthermore,neither Seller nor any of its officers, subcontractors, employees or agents, shall be liable for any damage caused to the building or property of the Buyer during the installation of the System unless Buyer serves written notice on Seller of the alleged damages within five(5)days following installation. 9.ARBITRATION:Any dispute arising under or related to this contract,including any tort action arising out of or related to the installation of the System,shall,if not resolved by the parties,be referred to binding arbitration.Only a court of competent jurisdiction shall have the right to determine if the subject matter of the proposed arbitration comes within the terms of this arbitration provision if the parties disagree as to the arbitrability of the matter. Arbitration shall be conducted in the Hillsborough County, Florida in accordance with Commercial Arbitration Rules of the American Arbitration Association then pertaining,and judgment on any award rendered in such arbitration may be entered in any state or federal court. The parties agree to allow the American Arbitration Association to choose the arbitrator,and its decision as to the selected arbitrator shall be binding unless either party can show the chosen arbitrator to be incompetent or biased for or against any parry.Notices in connection with such arbitration must be served by personal delivery or certified mail, return receipt requested, on Seller at its address stated on the front page hereto. Costs of arbitration, including the filing costs and related arbitrator fees, shall be awarded as determined by the arbitrator; but only a court having jurisdiction over the parties may make a determination whether attorneys fees are recoverable, and if so, in what amount. Notwithstanding the foregoing,the parties hereto,and those in privity with the parties hereto,agree that any action or suit to foreclose a mechanics lien brought pursuant to Chapter 713,Florida Statutes,shall be exempt from the application of this arbitration agreement. 10. MERGER:This contract, if accepted by Seller,represents the final expression of the representations,terms and covenants of the relationship established between Seller and Buyer and the installation of the System. Buyer agrees that Buyer is not relying upon any other representation or statement made heretofore by any sales agent,independent contractor or representative of Seller to Buyer as an inducement to enter into this contract, and Buyer releases Seller from any other inducement or representation that is not included herein, even if such representation was material to Buyer's decision to enter into this contract.Buyer agrees that only an officer or member of Seller has the authority to bind Seller to this contract,or waive or modify any of its terms. Furthermore,Buyer understands and agrees that no sales agent,independent contractor or employee of Seller has the right to promise Buyer that any rebate of any sort will be made or given with respect to the purchase or installation of the System. 11.GOVERNING LAW,VENUE:This contract is to be construed under and governed by the laws of the State of Florida.Any action,suit or other proceeding between the parties hereto, whether or not such action, suit or proceeding arises under this contract, shall be brought in Hillsborough County,Florida; and the parties agree to waive venue in any other county.However, if the suit or action includes a mechanic's lien foreclosure, venue shall be placed in the county where the System was installed. 12. NON-ASSIGNABILITY:Buyer may not assign this contract,nor any of Buyer's rights hereunder,to another. 13. PAYMENT:Buyer agrees to pay the full contract price on completion of the installation of the System,time being of the essence. 14. DEPOSIT:If the work order given in connection with this contract provides for Buyer to give Seller a deposit as a condition of Seller accepting Buyer's offer, Buyer shall have the right to withdraw its offer if the amount of the deposit is not agreeable to Buyer. Payment of the deposit to Seller's employee shall be conclusively deemed Buyer's agreement to enter into this contract and pay the deposit. Despite accepting such deposit, Seller shall not be obligated to apply for any permit within thirty days of accepting the deposit or commence work within 90 days of the permit(s) being issued,and the parties hereto waive application of Florida Statute§489.126(2)to the extent it applies to this contract,if at all. - 15. ACCEPTANCE: If Seller does not provide notice to Buyer that Seller has accepted Buyer's offer within forty days following the date Buyer signs this contract,Buyer's offer to enter into this contract shall expire.However, should Seller proceed to install the System following expiration of the acceptance period with Buyer's knowledge and approval,then the parties hereto shall be bound by the terms of this contract. Installation 11.10 l INSTR#2020190510 OR BK 10213 PG 1458 Page 1 of 1 11/10/2020 09:41 AM Rcpt:22?532r0 Rec:10.00 DS:0.00 IT:0.00 Nikki Alvarez-Sowles, Esq.,Pasco County Clerk&Comptroller PeardtNa Parcel IDNo2 L�NOTICE OF OF COMMENCEMENT Mao, CaumyOf THE UNDERSIGNED tlefa6y gives rtotlCe ifs ImprovwnentvNd be made to CaM reel pmparty,ana In aoomaamm Won Chapter 713,MOM 5latutes, the ram"irtanrtadon is moAM in this Na1roe of Cmimenoement 1. DssWpWn arPMPaW.Parcel Iaemalaaaon No. H j W yl yy\mSi,nh , o PR—i( q m i Lp-i I. SbeetAdfresn: 'A'1QQ �j =F-Q WQALZ L-MT--.. z Geran&Dascilption of Implovamera-,/` M SMAIEZ'i A)El sWE' 1-1- S. Owner Intafmadon or Lessee Information If uis Lessee conbaCed forum improvement: .Pn-forn Mrt)ornnbc) ?IW- r�s�esinv>n `�epintnrh�\1s AddAM Criy state interest In Property:-1 o/b -_ - Name of Fee Simple TWerlaaec (d different fern owrmr listed above) 4. Cam or tfi 5C71 state Norma Address Ctty Slate Comraaots Teleptlone Na: ' 5. Surety: Name Address Cdy State AmotudclBond:s TeteptimNo.: e. Lander. Name Address Cdy state LeMsea TelapWa No.: 7. Parsons within bm Stale of Ftodda desoWed by the owner upon whom notices or other daaumems may be salved as provides by Seaton 713.13(1)(e)(7),Florida Stehdes: Name Address cry State '- Telephone Number of DesiWailed Pemm S. In addition to himself,the awmer designates M to recalve a copy of the UwWs Natice as provided In Section 713.13(1)(b),Flail&Statute, Telephone Number of Paeon or ErM Designated by Owmr g. E.10ratlon We of NOW at Cornmart Mend(me motanon date may not be barons the completion of consmixtion and tint Menem to the contractor,tnd will be orla you f m are tau of recording unloss adt¢oterd date Is apecl8ed): WARNING TO OWNER ANY PAYMENTS MADE BY THE OWNER AFTER THE IEMRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER71la PAfTri,SECTION713.1 FLORIDA STATUTES, AND CAN RESULT RECORDED CO YOUR PAYING N TTHE TWICE OB SrM BED O THE FIAWM RST INSPECTION R YOU INTEND TO OBTAIOF N FINANCING CONSUT'MUST LT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDINGYOUR NOTICE OF COMMENCEMENT. ofmundery prmmty of pequry,I deaere that I have read iha roregoing rrotlW of oomm ant end tl a teas stated Marein are true to the best tmolNeage and bailer. L� STATE OF FLORIDA COUNTY OFPASCO Signature of Owner or Leese*,or Owrta'e orLaoseea Authorized OIfectofPartnedMarnager �gnatwy'aTNafOttlW , The rotagoing Iaauranent v s aaarowieagea baron ma mis au day QfQ,,A0W,zojD by__P-040-n as (type ofauhodty,og.,ottt er,tntotes.a meylnfed)for 2E (marna�tp on behalf a won tnetnm s e� d). Paismady Knew o LE Proar,wa Id Notary Solatu Type atl comProduced Name(Pdnt) %)rLS0r1 S. M(t7n vLc,e& JASON S.MONCHGESANG Notary Public-State of Florida '• �= Commission i GG 959064 wpd yC053048 ,�.fill"� My ebrUary 117,2024rea `�rrrr ` 7.04kW SOLAR ARRAY PLANS N OP PROJECT DESCRIPTION: : FOR 22 MODULES - MISSION SOLAR: MSE320SR8T GENERAL NOTES: �"`��' 22 INVERTERS ENPHASE: 107-60-2-US 1. THIS IS TO CERTIFY THAT TO THE BEST OF AA R 0 N M CC O M B S MY KNOWLEDGE AND BELIEF, THESE PLANS O '. CONFORM WITH FLORIDA BUILDING CODE 2017 GOVERNING CODES: WITH ALL SUPPLEMENTS AND ADDITIONS. 2017 FLORIDA PLUMBING CODE, 6TH EDITION 2. ALL PRODUCTS TO BE INSTALLED PER ,� 3292 KRESTERBROOKE LN 2017 FLORIDA BUILDING CODE, 6TH EDITION MANUFACTURER'S WRITTEN SPECIFICATIONS. 2017 FLORIDA MECHANICAL CODE, 6TH EDITION I, ANDREW D. HALL PE# 87479 AN ENGINEER Z EP HYR H LLS, FLO R DA 33540 NFPA 1 2015 NEC 2014 LICENSED PURSUANT TO CHAPTER 471, CERTIFY THAT THE PV ELECTRICAL SYSTEM AND ELECTRICAL COMPONENTS ARE DESIGNED AND APPROVED USING THE STANDARDS CONTAINED IN THE MOST RECENT VERSION OF THE FBC, FBC 107. Wind Design Data Wind Speed 140 mph Risk Category II Exposure C TYP. EAVE GustFactor *0.18 "A"Dimension 5.1 ft DISCONNECT Rnnf Preecure for Components and Cladding MIN. 4' CLEARANCE Zone 1 16.47 psf -25.65 psf PER NEC 110.26(A) Zone 2 16.47 psf -44,55 psf Zone 3 16.47 psf -66,15 psf I? r4 Y l 'i s•_ ---? TYP. RIDGE 3' MIN. TYP tT ALL WORK SHALL COt�lPLY WITH PREVAILING COAES FLORIpq BUILDING CODE, NATIONAL ELECTRIC CODE, AR MME I OF ZEPHYRHILLS REVIEW DA 3V 2 1DR"C-1WEX: PLAN OF�EPHyRH EkAMINER S-1 COVER TYP. EAVE MISSION SOLAR: S-2 ARRAY LAYOUT & DETAILS S-3 ELECTRICAL MSE320SRBT (TYP) S-4 NOTES MODULE ROOF LAYOUT NTs S-5 SPECIFICATIONS S-6 SPECIFICATIONS S-7 SPECIFICATIONS S-8 SPECIFICATIONS <P�O GE No I y1r; s �•• S A, I/ PV MODULE QMR-UMC CLIP 3/8"-16 X 3/4" HEX HEAD BOLT QMR 3/8" - 16 FLANGE NUT © CROSSRAIL LIGHT (TYP) SUNMODO NANO SUNMODO NANO RAFTER MOUNT QMR RAFTER MOUNT (TYP) CROSSRAIL LIGHT (TYP) TOP VIEW EXISTING UNDERLAYMENT NTS EXISTING ROOF TRUSS PLYWOOD 5/16" DIA SS LAC SCREW 2-1/2" EMBED MIN. TYPICAL SHINGLE ROOF ATTACHMENT NTS SUNMODO NANO RAFTER MOUNT 48" MAX. O.C. QMR-UMC CLIP (np) (TYP) QMR-UEC CLIP (TYP) MISSION SOLAR: MISSION SOLAR: o QMR-UEC MSE320SR8T QMR-UMC CLIP MSE320SR8T (TYP) (TYP) (TYP) of N W QMR-UMC CLIP QMR-RL14 (TYP) QMR-UEC CLIP (TYP) SUNMODO NANO RAFTER MOUNT (TYP) TYPICAL LAYOUT (TYP) NTS No J s �y A� o T 11111 ,,I�s #10 THWN-2 (3 CONDUCTOR) NOTE: 3/4" EMT, FMC, FOR EXTERIOR ALL INVERTERS ARE EQUIPPED APPLICATION USE PVC OR W/ INTERNAL RAPID SHUTDOWN LFMC/LFNMC CONDUIT #10 THWN-2 (3 CONDUCTOR) SYSTEM PER NEC 690.12 3/4" EMT, FMC, FOR EXTERIOR LOCKABLE FUSED APPLCATION USE PVC OR PV AC DISCONNECT LFMC/LFNMC CONDUIT ENPHASE Q CABLE MISSION SOLAR: MSE320SR8T W/ ENPHASE IQ7-60-2-US 30A 240V 2-POLE #10 THWN-2 (3 CONDUCTOR) ENPHASE Q CABLE 30A RK-1 FUSE 3/4" EMT, FMC, FOR EXTERIOR Q-12-10-240 Q 12-10(124; INVERTER APPLCATION USE PVC (NP)OR LFMC CONDUIT N L2 L1 METER AC AC L1 L1 6� DC DC L2 L2 NO. 1 NO. 11 N N SPACE 20 20 MR RL14 (PP)SPACE 20 G NO. 1 NO. 11 NOTE: #6 THWN-2 G ALL STRINGS TO HAVE ACN AC TERMINATORS & SEALING CAPS DC DC INSTALLED PER MANUFACTURER'S 30 760OV/ NON-FFUSED MBINER BOX SPECIFICATIONS NEUTRAL GROUND R - ] SOLTECTION RESIDENTIAL TRANSITION BOX ENPHASE Q CABLE MISSION SOLAR: MSE320SR8T GEC BOND AT Q-12-10-240 W/ ENPHASE IQ7-60-2-US I. ENPHASE IQ COMBINER PLUS RACKING SYSTEM (nP) INVERTER W/ (2) 20 AMP BREAKER (SEE NOTE #2) NEUTRAL GROUND AC PANEL 150 AMP/240V �ygCiaf o 8 NOTES: ��•: 1. ALL ASPECTS OF THE ELECTRICAL WORK REQUIRED TO COMPLETE THE PROJECT REPRESENTED IN THIS DOCUMENT �� fit` '• MODULE SPECIFICATION INVERTER SPECIFICATION SHALL COMPLY WITH THE MANUFACTURERS RECOMMENDATIONS/SPECIFICATIONS AND ALL CODES, STATUES AND MODULE MAKE MISSION SOLAR INVERTER MAKE ENPHASE STANDARDS ADOPTED BY THE STATE AND THE LOCAL AUTHORITY HAVING JURISDICTION. �ttt I MODULE MODEL MSE320SR8T INVERTER MODEL IQ7-60-2-US 2. ALL COMPONENTS MUST BE GROUNDED PER NEC 690.43. 3. ALL EQUIPMENT SHALL BE LISTED PER NEC 690.4(D). FSEC CERTIFICATION # MAX AC POWER OUTPUT 250 VA 4. THE INFORMATION PROVIDED IN THESE DOCUMENTS IS NOT EXHAUSTIVE. IT REMAINS THE CONTRACTORS PMAX (STC) 320 W MAX. INPUT VOLTAGE 48 V RESPONSIBILITY TO ACHIEVE THE PROPOSED INSTALLATION, IN FULL EXERCISE OF AND COMPLIANCE WITH THE VOC (STC) 40.80 V NOM. DC VOLTAGE ® 240V 240 V ITEMS IDENTIFIED IN NOTE 1. VMPP (STC) 34.22 V NOM. AC VOLTAGE 16-48 V 5. PER NEC 690.17 PROVIDE A WARNING SIGN AT ALL LOCATIONS WHERE TERMINALS OF THE DISCONNECTING MEANS BE ENERGIZED IN THE OPEN POSITIONS. SIGN SHALL READ "WARNING-ELECTRIC SHOCK HAZARD - DO ISC (STC) 10.03 A MAX. CONTINUOUS OUTPUT CURRENT 1.00 A MAX. DC CURRENT 15.0 A NOT TOUCH TERMINALS - TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN IMPP (STC) 9.35 APOSITION OR EQUIVALENT. NOCT 46 C MAX. DC POWER (STC) 350 W 6. PER NEC 705.10, PROVIDE A PERMANENT PLAQUE OR DIRECTORY SHOWING ALL ELECTRIC POWER SOURCES ON TC ISC 0.039 %/C CEC EFFICIENCY 97 % THE PREMISES AT SERVICE ENTRANCE. TC VOC -0.280 %/C 7. INTERCONNECTION METHOD SHALL COMPLY WITH NEC 705.12. TC PMPP -0.377 %/C 8. PV METER MAY OR MAY NOT BE REQUIRED BY THE AHJ AND/OR UTILITY FOR INTERCONNECTION. OPERATING TEMP. -40-+85 C 9. CONDUCTOR SIZING OF THIS DESIGN IS BASED ON RACEWAYS LOCATED OUTSIDE ATTICS OR NOT EXPOSED TO DIRECT SUNLIGHT. WHERE TWO DIFFERENT AMPACITIES APPLY TO ADJACENT PORTIONS OF A CIRCUIT, THE HIGHER AMPACITY SHALL BE PERMITTED TO BE USED BEYOND THE POINT OF TRANSITION, A DISTANCE EQUAL TO 3.OM (loft) OR 10 PERCENT OF THE CIRCUIT LENGTH FIGURED AT THE HIGHER AMPACITY, WHICH EVER IS LESS. NEC 310.15 (B)(2) SAFETY LABELS AND MARKINGS GENERAL NOTES: N A N EMERGENCY CONTACT 10.ALL CONDUCTORS AND RACEWAYS SHALL BE SUPPORTED ON INTERVALS AND BY METHODS REQUIRED BY THE NEC. 1 SHALL EQUIPMENT SUCH LABE AS FOUND HER EIN RE N SOLAR B MODULES APPLIED TO SUCH U S S O EA R 12.PV ARRAY INTERCONNECTION TO BE MADE WITH BACK-FEED BREAKER. PRE-APPLIED 13.GFI BUILT IN TO ALL INVERTERS. EQUIPMENT FOR INFORMATIONAL PURPOSES. 2. LABELS AND MARKINGS SHALL BE APPLIED TO COMPONENTS IN 1 -813-4 3 4-0284 ACCORDANCE WITH THE CURRENTLY ADOPTED EDITION OF NEC. 3. ALL REQUIRED PRODUCT SAFETY AND WARNING SIGNAGE SHALL BE UV RESISTANT OUTDOOR-RATED LAMINATED VINYL IN ACCORDANCE WITH ANSI Z535.4-201 1. SAFETY LABELS AND MARKINGS LEGEND A. LOCATION OF SERVICE DISCONNECTING MEANS. APPLY TO MAIN SERVICE DISCONNECTING MEANS AND PV DISCONNECTING MEANS AT POCC. MAIN SERVICE DISCONNECT MARKING \ CAUTION SOLAR PHOTOVOLTAIC SYSTEM i A LABEL SHALL BE PERMANENTLY AFFIXED TO THE MAIN SERVICE ® -WARNING- -WARNING- DISCONNECT PANEL SERVING ALTERNATING CURRENT (AC) AND DIRECT THIS SERVICE IS SUPPLIED BY MULTIPLE ELECTRIC SHOCK HAZARD. THE DC PHOTOVOLTAIC CURRENT (DC) PHOTOVOLTAIC SYSTEMS. THE LABEL SHALL BE RED WITH SOURCES. SEE DISCONNECTS BELOW. AUTHORIZED PERSONNEL ONLY CONDUCT MRSYSIEM ARE U GIROU DED AND WHITE CAPITAL LETTERS AT LEAST 3/4 IN. IN HEIGHT AND IN A RATED AC CURRENT: 27.5A MAY BE ENERGIZED AUTHORIZED PERSONNEL ONLY NONSERIF FONT, TO READ: "WARNING: PHOTOVOLTAIC POWER SOURCE." NOMINAL AC VOLTAGE: 240V THE MATERIALS USED FOR THE LABEL SHALL BE REFLECTIVE, WEATHER LOCATION: MAIN PV PANEL LOCATION: DISCONNECTS, INVERTERS, JUNCTION BOXES, OTHER ENCLOSES RESISTANT, AND SUITABLE FOR THE ENVIRONMENT. HOLDING DC CONDUCTORS CIRCUIT DISCONNECTING MEANS MARKING A PERMANENT LABEL SHALL BE AFFIXED ADJACENT TO THE CIRCUIT PHOTOVOLTAIC DISCONNECT BREAKER CONTROLLING THE INVERTER OR OTHER PHOTOVOLTAIC SYSTEM ELECTRICAL CONTROLLER SERVING AC AND DC PHOTOVOLTAIC SYSTEMS. THE LABEL SHALL HAVE CONTRASTING COLOR WITH CAPITAL LETTERS AT -WARNING- LEAST 3/8 IN. HEIGHT AND IN A NONSERIF FONT, TO READ: w ARWY ELECTRIC SHOCK HAZARD PHOTOVOLTAIC SYSTEM EQUIPPED "PHOTOVOLTAIC DISCONNECT." THE LABEL SHALL BE CONSTRUCTED OF DO NOT TOUCH TERMINALS.TERMINALS ON WITH RAPID SYSTEM SHUTDOWN DURABLE ADHESIVE MATERIAL OR OTHER APPROVED MATERIAL. BOTH THE ENERGIZED IN TH LOAD sIPOS MAY BE HE OPEN P05R10N. LOCATION: AC DISCONNECT(S) pSSI NO PERC 60 CLASS LEADING 315-32ti•v�1 • Eliphase IQ 7 and IQ 7+Microinverters ,�, IS' L Electrical Parameters at Standard Test Conditions(STC) _ _ -i Ito•PUT DATA(MC) 1O7-60-2-US IQ7PLUS-72-2-US Module Type MSE315SRST MISE32DSRST MSE3255ROT IEC yPeCr s o;!w d , 01e pairings' ?35W-350W+ 235 W-445 W+ Power Output Pmax Wp 315 320 325 61215-61730-61701-Salt mist Art,:•9ule-crrpatibility 60=ce f pV modules only 60-cell and/2-cell PV modules Module Efficiency % 18.65 18.94 19.24 UL kiaximur^,l,lput DC voltage 48 V 60 V Tolerance 0-+3% 0'+3% 0-+3,, Pack porter tracking voltage 27 V-37 V 27 V-45 V UL 1703 listed Operating range 15V-48 V 16 V-60 V Short-Circuit Current Ise A Sift!? 10.1301 101 .l d _ Min/Max start voltage 22 V/48 V 22 V/60 V Open Circuit Voltage Voc V 40.44 40.80 41.14 c®us CEC 1W Max DC short circuit current(module isc) 153 15 A Rated Current Imp A 9.253 9.361 9.387 tie Overvollage class DC port II Ii Rated Voltage Vmp V 34.04 34.22 34.62 DC port backfeed current 0 A 03 PV array configuration x 1 ungrounded array;No additional DC side protection required; Fuse Rating 20 20 20 AC side protection requires max 20A per branch circuit OUTPUT DATA(AC) 1Q7 Microlnverter IQ 7+Microinverter _ • Peak output power — 250 VA 295 VA "G SE334SRST:320WP,60 CELL SOLAR MODULE Maximum continuous output power 240 VA 290 VA Normal Operating Cell Temperature(M0CT) 46.09°C(t2°C) CURRENT-VOLTAGE CURVE Nominal(L-L)voltage/ranger 240 V! 208 V/ 240 V/ 203V/ Temperature Coefficient of Pmax -0.377%1°C 211-264 V 183.229 V 211-264 V 183-229 V xx Maximum continuous output current 1.0A 1.159 1.21 A 1.39 A Temperature Coefficient of Voc -0.280%I°C cots Toss-ass Nominal frequency 60 Hz 60 Hz Temperature Coefficient of Ise 0.039°,61°C 1a _ Incident lord.=I000 W/& Extended frequency range 47-68 Hz 47-68 Hz AC short circuit fault current over 3 cycles 5.8 Arms 5,8 Arms c Irrdden! rood.=gee Wlm2 ■° i s i a — Maximum units per 20 A(L-L)branch circuit' 16(240 VAC) 13(240 VAC) Incident Irrd.=U00 WJm 13(208 VAC} 11(208 VAC) f laxlrnum System Voltage 1,DD0VdC Overvoltage class AC port Ill Ill Operating Temperature Range X10°C{-40°F}to+85°C(985°F) d Incident Imd.=400 w/m2 AC port t:eckfeed current 0 A 0 A Power factor getting 1.0 1.0 Maximum Series Fuse Rating 20A Incident trod.=zeo w/m2 Power factor ad u.,table 0.7 leadin 0.7 la ing 0.7 leadin 0.7 la in ' ( i } g... 99 g•�- 99. 9 Fire Safety Classification Type 1,Class C �'* ` EFFICIENCY @240V @208 V @240V @208 V Front&Baek Load(UL standard) 5631 Pa(117 psi) or Peak cEc efficiency 97.6% 97.6% 97.5% 913% —� Tested to UL1703 standard a r" �" " ' CEC weighted efficiency 97.0% 97.0% 97.0% 97.0% Hall Safety impact Velocity 25mm at 23 m/s Voltage M MECHANICAL DATA 107 Microinverter Current-voitage characteristics with dependence on irradlance — �—. _ _ and fnODU�tarY�TBratUre Ambient temtlorAtme rnnrjm -4floC in +6.rinr.a Relative humidity range 4%to 100%(condensing) Solar Cells P-type mono-crystalline silicon (158.75mm) Connector type MC4(or Amphenol H4 UTX with additional Q-DCC-5 adapter) Dimensions(WxHxD) 212 mm x 175 mm x 30.2 mm(without bracketl Cell Orientation 60 calla(6x10),5 bulbar BASK DESIGN(UNITS:mina) Weight 1.08 kg(2.38 Ibs) 1Module Dimension (6.98 in x 10.68 in x 40ri Cooling Natural convection-No fans {65.88 in.x 39.68 in.x 1.58 in.) Weight 20 kg(441b) ns a° Approved for wet locations Yes I]Ill_II_U_1_I_1111111111_II_I Pollution degree PD3 Front Glass 32mm(0.126efle tempered. I Iii_II_ 1_11111111111_I_1_II Encloses' Class It double-insulated,corrosion resistant polymeric enclosure IHU_II_14_Ubw-iron,anti-rofWctive nroaling na mlilfl14llllll.}_I " ,av Environmental category/UV exposure rating NEMA Type 6/outdoor Frame Anodized aluminum alloy Iifl_ ii 1r FEATUJI•'OS F_ncapsulant Ethylene vinyl acetate(EVA) llHiI_1I1JIJUIIIIIHfi1[_ii nav Communication �.F Power Line Communication(PLC)-- J-Box Protection class IP67 with 3 bypass- odes .em liiiill_I FI__I ljfl 111111 I_J_I_II Monitoring Enlighten Manager and MyEniighten monitoring options. - !1ff1fH_fllit+I+IMfthIVI(IIlI_I_II °° - Both options require installation of an Enphase IQ Envoy. Cables PV wire,1m(39.37 in.),4mmx J 12 AWGItII+114_+1-Ill_11111161111 1-114 °�"t"R Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load-break Connector MC4 Compatible Mffl1 _IIJI1IIIIII!!J]IIII!1I1 disconnect required by NEC 690. 1I11111111 lllllllllllfllllflhlfl'Il Compliance CA Rulo 21(UL 1341-SA) _ UWUUI IllhJJLULIiI1L1UI1I I �- UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B,ICES-0003 Class B. • • CAN/CSA-C22.2NO.107.1-01 i This product Is UL Lasted as PV Rapid Shut Down Equipment and conforms with NEC-2074 and Corrtainer FT Pallets Panels 320 W 1 _�� _ NEC-2017 section 690.12 and C22.1-201 5 Rule 64-218 Rapid Shutdown of PV Systems,for AC erd DC conductors,when instaSed according manufneturc'r's lnt:lraction3. Double stack 36 936 299.52 kW — — — Front View Back View I.No enforcedD'CfF,Cretlo.See thecomp alb:i.tycalcUatorat 11Ltp5eapLasc.comle n-ys/su nnonlPlftiLidtQ-cpmn,t�. 40' Double stack 28 728 232.96 kW 2.Nominal voitere ranne can be extended beyond nominal if requirod by the ut lity. 3.Lirnit rray•car.r:e`er to local regsirements tc def'ne the number of microinverters per branch in yo.:r area. Panels Weight Height Width Length Pallet 26 1,198k 42.45° 45-50' 67.00' C r�r� C /� •p'F To learn more about Enphase offerings,visit enphase.com E N PHAS E MISSI❑N SOL✓ R 7 n l 'x,r.t r,ry Al In y ie nisi Alla ri. ks-ir brands r,vi dre&e Cp'rivol nil 'F Er go Inc, ENERGY -a ' 21 t02 u8 Mission Solar Enerp��«_�.°°u,=dasn,r i,,.,ws ter+«;o..uv.�w..,,y�,,,unwt,,,,us= Mission Soli.Er.ngy i 8303 S.New Braunfels Ave..San Antonio.7cxas 7E235 r-:-. C.-, ax rr. r-t orb '.,r... s.:; InTn mis'fenselar.com l tvww.masionsolarcrm . t' O $� = �c Enphase Q Cable Accessories Enphase IQ Combiner 3 MODEL NUMBER Q AGGREGATOR SPECIFICATIONS !q Combiner 3 IQ Combiner 3 with Enphase IQ Envoy'printed circuit board for integrated revenue grade PV �- r� _T - _ X-IQ-AMl-240-3 production metering(ANSI C12.20+/-0.5t 1 and optional*consumption monitoring(i-/-2.5%). Q Aggregator Q-BA-3-1 P-60(single-phase).Combines up to three microinverter branches into one home run, Protect with maximum 60A,2-pie OCPD. ACCESSORIES and REPLACEMENT PARTS(not included.order,eparate!y) Q Commercial Aggregator Q-BA-3.3P-35(three-phase).Combines upto three,single-phase microinverter branches into a three- Enphase Mobile Ccn'feet`" phase home run.Protect with maximum 40 A,3-pole OCPD. CELLMODEM-03(4G/12-year data plan) Plug and play Industrial grade cellular modern with data plan for systems up to 60 CELLMODEM-01(3G/5-year data plan) microinverters.(Available in the US,Canada,Mexico,Puerto Rico,and the US Virgin Islands, Dimensions 190 mm(W)x 227 mm(D)x 80 mm(H)17.5 in(W)x 9 in(D)x 3.2 in(1-I)7 CELLMODEM-M1(4G based TE-M/5 year data plan) where there is adequate cellular service In the Installation area.) Homerun conductor size range #12 to#4 AWG Consumption Monitoring*CT Split core current transformers enable whole home consumption metering(+/-2-5%). CT-200-SPLIT Enclosure rating NEMAS(up to 45°from horizontal) c m :n r t m.n g.:r= :eri rar r�aat^ tr Gten� Temperature range -40'C to+55'C(-40'Flo+122'F) Wireless USd adapter Installed at the 1Q Envoy.I'or communicartions with`Enphase Encharge"storage and Enphase COMMS-KIT 01 Enpower"smart switch.Includes USR cable for connection to IQ Envoy or Enphase IQ Combiner" Compliance UL1741(assembled product)and UL6703(bulkhead connectors) and allows redundant wireless communication with Encharge and Enpower, Circuit Breakers Supports Eaton 0R210,BR215,BR220,BR230,BR240,BR250,and BR260 circuit breakers. CONDUCTOR SPECIFICATIONS BRK-1CA-2-240 Circuit breaker,2 pole,10A,Eaton BR210 Certification UL3003(raw cable).UL 9703(cable assemblies),DG cable BRK•155 2.240 Circuit breaker,2 pole,l5A,Eaton 8R215 Flame test rating FT4 BRK-20A-2P-240 Circuit breaker,2 pole.20A,Eaton BR220 EPLC-01 Power line carrier(communication bridge pair).q:iantity-one pair Compliance ROHS,OIL RES I,CE,UV resistant,combined UL forihe United States XA-PLUG 1211-3 Accessory receptacle for Power Line Carrier in IO Combiner 3(required for EPIC-Cl) Conductortype TIHNITHWN-2 dry/wet ' XA-ENV-PC-SA-;3 Replacement 1O Envoy printed circuit board{PCB)for Combiner 3 Disconnecting means The AC and DC bulhead connectors have been evaluated and approved by UL for use asthe load-break - disconnect required by'NEC 690, ELECTRICAL SPECIFICATIONS Q_CABLE TYPES/ORDERING OPTIONS hating Continuous duty Model Number Max Nominal Voltage Connector Spacing PV Module Orientation Connector Count per Box Sy_iem voltage 1201240 VAC,60 Hz Q-12-10-240 277 VAC 1,3 m(4.2ft) Portrait 240 Eutun BR serh's busbar rating 125 A 0-12-17-240 277 VAC 2.0 m(6.5 ft) Landscape(60-cell) 240 Max.continuous current rating(output to grid) 65 A Q-12-20-200 277 VAC 2,3 m(7.5 ft) Landscape(72-cell) 200 Max.fuse/circuit rating(output) 90 A ENPHASE Q CABLE ACCESSORIES Branch circuits(solar and/or storage) Up to four 2-pole Eaton BR sc,ies Distributed Generation(DG)breakers only(not included) Name Model Number Description Max.continuous current rating(input from PV) 64 A Raw Q Cable Q-12-RAW-200 300 meters of 12AWG cable with no connectors Max.total branch circuit breaker rating(input) BOA of distributed generation/90A with IQ Envoy breaker included Field-wireable connector(male) Q-CONN-10M Make connections from any Q Aggregator open connector Production Meterrrg CT 200 A solid core pre-installed and wired to IQ Envoy Field-wireabie connector(female) Q-CONN-10F Make connections from any 0 Cable open connector MECHANICAL DATA Cabe Clip Q-CLIP-100 Used to fasten cabling to the racking or to secure looped cabling Dimensions(WxHxO)� 49-5 x375 x 16.8 cm(19.5'x 14.75"x 6,63").Height is 21.06"(53.5 cm with mounting brackets). Disconnect tool Q-DISC-10 Disoonnecttool for 0 Cable connectors,DO connectors,and AC module mount Weight 7.5 kg(16.51bs) Q Aggregator sealing caps(male) Q-BA-CAP-1 D Sealing cap for unused aggregator connections Ambient temperature range -40°C to+46°C(.40°toll 5°F) Q Cable sealing caps(female) Q-SEAL-10 One needed to cover each unused connector on the cabling Croling Natural convection,plus heat shield Terminator O-TERM-10 Terminator cap for unused cable ends Enclosure rneiro.m•ntal rating Outdoor,NRTL-certified,NEMA type 3R,polycarbonate construction Replacement DC Adaptor(MC4) Q-DCC-2 DC adaptorto MC4(max voltage 100 VOC) Wire sizes • 20 A to 50 A breaker inputs: 14 to 4 AWG copper conductors Replacement DC Adaptor(UTX) 60 A breaker branch input: 4 to 1/0 AWG copper conductors p Q-DCC-5 DC adaptor to UTX(max voltage 100 VDC) • Main lug combined output: 10 to 2/0 AWG copper conductors Neutral and ground: 14 to 1/0 copper conductors _ Always foilow local code requirements for conductor sizing. TERMINATOR SEALING CAPS Altitude To 2000 meters(6,560 feet) Terminator cap cfor of sed cable for tionedaggregator tNTERHETCONNECTIONOPTIONS ends,sgld in packs of ten and cable connections Integrated Wi-Fl ______ -- -• 7;02.11b7 - ----_- _ _ __.. .. _ �..�. _ (Q-TERM-1O) (Q•BA-CAP-10 and Q-SEAL-10) 4g/n Ethernet Optional,802.3,Cet5E(or Cat 6)UTP Ethernet cable(not Included) — Cellular Optional,CELLMODEM-C1(3G)or CELLMODEM-03(4G)orCELLMOLcEM-M1(4G based LTE-M) DISCONNECT TOOL CABLE CLIP (not included) Plan to use at least one per Used to fasten cabling to the racking I COMPLIANCE installation,sold in packs often or to secure looped cabling,sold in — -- I k packs often(Q•CLIP•lDO) Gompliancr�,Combiner UL 1741,CAN/CSA C22.2 No.1071,47 CFR,Part 15,Class B,ICES 003 (Q-DISC-'10) Production metering:ANSI 012.20 accuracy class 0.5(PV production) Ccmplianrc-,lQ'rnvvy UL60601-i/CANCSA22.2 No,61010-1 To learn more about Enphase offerings,visit enphase.com To learn more about Enphase offerings,visit enphase.cam a via All rigl,te"rverved.Enphase:he En,rt,ase logo,IC CUmrner 3,sat dt tracerrarksor set vice napes err the C 2018 Enphase Energy.Al riches reserved-All uadernarks or brands usc-d are the property or Erpnasc Fnc,gy,' h'p�,J tradLmarFs 71 Erp u'x E• rly.]rrc_ eE N P H AS E. "201361-90 v ENPHASE. '21`9.1+-04 ,=z�asac Na a - . SUNM*fiPWOAL3___ rr 5 levels of protection against Aesthetically pleasing ' • water penetration unibody aluminum cost " A ■ ■ construction 360-degree positioning, serrated surface on both ATTACHMENT sides for rail mounting T _____________________________ Versatile mounting option includes direct-to-decking for fast installation . - i Integrated Ultra Soft Weather Resistant silicone gasket Alignment markers t • . • • . • • - - • The NanoMount Advantage enable easy installation -/ The fastest roof attachment in • _ solar ./ Versatile mounting options including direct-to-decking i •i i - - • i f Eliminates the need to lift • • • • • shingles and prevents damage to Application Composite shingle and rolled asphalt shingle Material High grade aluminum, 304 stainless steel hardware • i . • / High-Velocity Hurricane Zone Finish Block powder coating . . - . . - . t- Approved - Passed TAS 100 (a) Roof Attachment Rafter and decking : ' • / All materials are compatible_ Wind-Driven Rain Test Structural integrity IBC and IRC Compliant • • ' • with Warranty 25 years • • - roof shingles SunModo, Corp. Vancouver, WA., USA •www.sunmodo.com • 360.844.0048 • info@sunmodo,com No 8 m ,, . • c.r p,� ' .s' R�1 Structural Quick Mount PV' ENGINUITY RESPECT THE ROOF Ingenuity in Engineering Rail Spans for Quick Mount PV QRall Light System Mean Roof Height: 0< h 515 ft Panel Orientation: Portrait Table 3 Roof Angle: 7<0 5 27 degrees Exposure Category: C Roof Ground Wind Speed(mph) Wind Snow I Zone Load 100 110 115 120 130 140 150 160 170 175 180 190 0 81 81 81 81 81 76 71 66 62 60 59 55 10 76 75 74 73 71 69 67 66 62 60 59 55 20 61 61 61 61 60 59 58 56 55 55 54 53 30 52 52 52 52 52 52 51 50 50 49 49 48 Zone 40 45 45 45 45 45 45 45 45 45 45 45 44 1 50 41 41 41 41 41 41 41 41 41 41 41 41 60 38 38 38 38 38 38 38 38 38 38 38 38 70 35 35 35 35 35 35 35 35 35 35 35 35 80 33 33 33 33 33 33 33 33 33 33 33 33 90 31 31 31 31 31 31 31 31 31 31 31 31 0 78 70 67 64 59 55 51 48 45 43 42 40 10 76 70 67 64 59 55 51 48 45 43 42 40 20 61 61 61 61 59 55 51 48 45 43 42 40 30 52 52 52 52 52 52 51 48 45 43 42 40 Zone 40 45 45 45 45 45 45 45 45 45 43 42 40 2 50 41 41 41 41 41 41 41 41 41 41 41 40 60 38 38 38 38 38 38 38 38 38 38 38 38 70 35 35 35 35 35 35 35 35 35 35 35 35 80 33 33 33 33 33 33 33 33 33 33 33 33 90 31 31 31 31 31 31 31 31 31 31 31 31 0 62 56 54 52 48 44 41 38 36 35 34 32 10 62 56 54 52 48 44 41 38 36 35 34 32 20 61 56 54 52 48 44 41 38 36 35 34 32 30 52 52 52 52 48 44 41 38 36 35 34 32 Zone 40 45 45 45 45 45 44 41 38 36 35 34 32 3 50 41 41 41 41 41 41 41 38 36 35 34 32 60 38 38 38 38 38 38 38 38 36 35 34 32 70 35 35 35 35 35 35 35 35 35 35 34 32 80 33 33 33 33 33 33 33 33 33 33 33 32 90 31 31 31 31 31 31 31 31 31 31 31 31 Notes: 1. Tables are based on critical rail span for load combinations as specified in chapter 2 of the ASCE 7-10 and allowable design loads per the 2015 Aluminum Design Manual. 2. Panels are assumed to be in portrait orientation with a maximum length of 67.5" 959 Larchmont Court,Aurora,IL 60504 3/4/2019 630.219-1997(P) www.structuralenginuityinc.com C3