Loading...
HomeMy WebLinkAbout20-1133 9 City Of ZephyrhiliS �RERMIT NUMBER 5335 Eighth Street Zephyrhills, FL 33542 BNR-001133-2020 ' Phone: (813)780-0020 x Fax: (813)780-0021 Issue Date: 12/15/2020 Permit Type: Building New (Residential) ter% "Propertjl Number "44.- Street Add ress°r 24 26 21 0110 00000 2310 39673 Harvest Creek Lane aOrwner9nf6rrration,;,. Pormit Information, Contractor Information = _ Name: LENNAR HOMES LLC Permit Type:Building New(Residential) Contractor: LENNAR HOMES LLC Class of Work:SFR Construct Address: 4600 W Cypress St 200 Building Valuation:$225,863.25 TAMPA,FL 33607 Electrical Valuation:$33,879.49 Phone: (813)574-5700 Mechanical Valuation:$15,810.43 16 Plumbing Valuation:$22,586.33 Total Valuation:$298,139.50 Total Fees:$18,729.23 Amount Paid:$18,729.23 Date Paid:12/15/2020 8:25:06AM Pt�otectDescription 4 ` CONSTRUCT SINGLE FAMILY 2,005 SQ FT-HIDDEN RIVER Application°Fees k w. Building Plan Review Fee $579.66 SIF 1 percent Fee $83.28 Electrical Plan Review Fee $104.70 Park Impact Fee-Single Family/Townhome $769.56 Driveway Fee $45.00 Plumbing Plan Review Fee $76.46 Mechanical Permit Fee $119.05 School Impact Fee $8,328.00 Building Permit Fee $1,159.32 Transportation Impact Fee-City $36.32 Sewer Connection Residential Fee $2,090.00 Transportation Impact Fee $3,595.68 Electrical Permit Fee $209.40 Public Safety Impact Fee-Police $254.00 Plumbing Permit Fee $152.93 Mechanical Plan Review Fee $59.52 Water Connection Residential Fee $1,010.00 Public Safety Impact Fee-Admin $26.35 Address Fee $30.00 REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each subsequent reinspection. Notice: In addition to the requirements of this permit,there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permit required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner:Your failure to record a notice of commencement may result in your paying twice for improvements to your property.If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications add fee Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. CONTRACTOR SIGNATURE PEP IT OFFICE PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER INVOICE1111 ' : FOR OF BILLING CONTACT STEVE SMITH LENNAR HOMES LLC 4600 W CYPRESS ST TAMPA, FL 33607 i INVOICE NUMBER INVOICE DATE INVOICE DUE DATE INVOICE STATUS INVOICE DESCRIPTION INV-00001982 11/24/2020 11/24/2020 Invoiced, Past Due NONE REFERENCE NUMBER FEE NAME TOTAL BNR-001133-2020 Address Fee $30.00 Building Permit Fee $1,159.32 Building Plan Review Fee $579.66 Driveway Fee $45.00 Electrical Permit Fee $209.40 Electrical Plan Review Fee $104.70 Mechanical Permit Fee $119.05 Mechanical Plan Review Fee $59.52 Park Impact Fee-Single Family/Townhome $769.56 Plumbing Permit Fee $152.93 Plumbing Plan Review Fee $76.46 Public Safety Impact Fee-Admin $26.35 Public Safety Impact Fee-Police $254.00 School Impact Fee $8,328.00 Sewer Connection Residential Fee $2,090.00 SIF 1 percent Fee $83.28 Transportation Impact Fee $3,595.68 Transportation Impact Fee-City $36.32 Water Connection Residential Fee $1,010.00 39673 Harvest Creek Lane Zephyrhills, FLORIDA 33540 SUB TOTAL $18,729.23 REMITTANCE INFORMATION TOTAL $18,729.23 City of Zephyrhills 5335 8th Street Zephyrhills, FL 33542 November 25,2020 5335 8th Street,Zephyrhills,FL 33542 Page 1 of 1 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department Date Received Phone Contact for Permitting 813 363 2891 -U-U-r 1_r-r- Owner's Name Lennar Homes,LLC Owner Phone Number 7813'5274.5700 0 Owner's Address 1 4600 W.Cypress St.Ste.200,Tampa,FL 33607 Owner Phone Number Fee Simple Titleholder Name I N/A Owner Phone Number Fee Simple Titleholder Address N/A JOB ADDRESS 39673 Harvest Creek Lane LOT# 0231 SUBDIVISION Hidden River Phase 2 PARCEL ID# 24-26-21-0110-00000-2310 �� (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED II./ II NEW CONSTR e ADD/ALT SIGN DEMOLISH INSTALL REPAIR PROPOSED USE SFR Q COMM OTHER TYPE OF CONSTRUCTION BLOCK 0 FRAME STEEL 0 DESCRIPTION OF WORK Single Family Residence/Pool/Screen Enclosure/Fence BUILDING SIZE U/R SF 2005 SQ FOOTAGE 1555 HEIGHT 1 Story ��✓ BUILDING $ $225,863.25 VALUATION OF TOTAL CONSTRUCTION W) $33,879.49 AMP SERVICE ELECTRICAL $ ® PROGRESS ENERGY Q W.R.E.C. ,��i„...... «rrrr PLUMBING $ $22,586.33 1 4+4W, 1 ,�MECHANICAL $ $15,810.43 VALUATION OF MECHANICAL INSTALLATION „=GAS ROOFING Q SPECIALTY 0 OTHER i FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA YES Do -��1�.�1--Fl�ll-ill-CFI-MITI--1--�I�II-CFI--1--1-�1--�Il��ll-4•1-11�-4-11-��11-�H• '�'-'-• II-III-UHF BUILDER COMPANY I Lennar Homes,LLC SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address 4600 W.Cypress St.Ste.200,Ta a,FL 33607 License# CGC1518166 ELECTRICIAN COMPANY Edmonson Electric, Inc. SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address 1034 Skipper Road,Tampa, L 33613 License# EC13005408 PLUMBER COMPANY Bayonet Plumbing, Heating &AC, Inc SIGNATURE REGISTERED Y/ N FEE CURREN Address P.O. Box 5308, Bayonet, FL 4674- 08 License# CFC042998 MECHANICAL COMPANY Bayonet Plumbing, Heating &AC, Inc SIGNATURE REGISTERED Y/ N FEE CURREN I Y/N Address P.O. Box 5308, Bayonet, FL 346 -5308 License# 7CAC058062 OTHER COMPANY C Sterling Quality Roofing, Inc SIGNATURE REGISTERED Y/ N FEE CURREN Address 4211 Shoal Line Blvd, Spring Hill, FL 34607 License# 1 CCC057991 1111111111111111111111111111111111111111111111111111111111111111111 RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster;Site Work Permit for subdivisions/large projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction. Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. ****PROPERTY SURVEY required for all NEW construction. Directions: Fill out application completely. Owner&Contractor sign back of application,notarized If over$2500,a Notice of Commencement is required. (A/C upgrades over$7500) ** Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage) Driveways-Not over Counter if on public roadways..needs ROW i NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed" restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due,they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713, Florida Statutes, as amended): If valuation of work is$2,500.00 or more, I certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the"owner', I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner"prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what,actions I must take to be in compliance. Such agencies include but are not limited to: - Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands, Water/Wastewater Treatment. - Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. - Army Corps of Engineers-Seawalls, Docks, Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. - US Environmental Protection Agency-Asbestos abatement. - Federal Aviation Authority-Runways. I understand that the following restrictions apply to the use of fill: - Use of fill is not allowed in Flood Zone"V" unless expressly permitted. - If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume" will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. - If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction, I certify that fill will be used only to fill the area within the stem wall. - If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill, an engineered drainage plan is required. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six(6)months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety(90)consecutive days, the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT _ W-ITM YOUR LENDER OR AINLATTORNEY BEFORE RECORDING YOUR NOTICE COMMENCEMENT. FLORIDA JURAT(F.S.117.03) - - - — — OWNER OR AGENT CONTRACTOR Subscribed and sworn to(or affi before me this Subscribed and sworn to(or affirmed)before me this ZO—UG[—LU by Ashlee Callahan zs-ool-zo by Ashlee Callahan Who is/are personally known to me or CL Who is/are personally known to me or identification. as identification. Notary Public Notary Public Commission No. HH 000460 Commission No. HH 000460 Elissa M.Holleran Elissa M.Holleran Name of Notary typed,printed or stamped Name of Notary typed,printed or stamped ELISSAM.HOLLERAN ELISSAM.HOLLERAN ;,,Commission#HH 000460 ,,• ■_.Commission#HH 000460 o' Exp(res.Juno 6,2024 _ e`/Expires June 6,2024 ••.$,•t.••' BonMft Troy Faln Insurance 000.39&7010 R„t••' BondWTtuu Troy Faln Insurance 800.385.7010 i I , PASCO COUNTY, FLORIDA PBrptit No.. J� . Date Pennlitad 77- Bulider.NemelOwner.Name Control#' �,'` �p1 C 1 County parcel No. !�7.6 2i1. 6/�d QQ�a���SutiDiv: Address/Location ClassiflcallonlType of Usq cg'/ e TRANSPORTAMON IMPACT.FEE Rate: SqA Unit: Q os Exempt ❑Yes ❑No How Determined Impact Fae Amount c7i�3Z Zone No. TAZ: I SCHOOL IMPACT FEE l� Account (Otte) Single-Family Detached House Amount S f (057) Mobile Home (058) Other Residential 123) Collection Fee f Exempt Yes ❑No How Determined PARKS AND.RECREATION FEE. Land Account - Land Credit Land Total j Recreation Account Recreation Credit .Recreations TTow Zone TOTAL AMOUNT $ L �� 6-6_ I Exempt D Yes ❑No How Determined LIBRARY,FEE Land Account Lend Credit Land Total Facillty.Accdunt Facility Credit FacllltyTotal Exempt Q Yes ❑No How Determined Total Amount RESOURCE FEE , ERU TOTALAMOUNT Prepared By Checked By NO CERTIFICATE OF.OCCUPANCY WILL:IBEISSUED.OR;FINAL INSPECTION PERFbamsDUNTILTHE TOTAL AMOIINT$'.LISTEDHAVE " •BLEEN.PAID AND° RECEIPTED FOR BY A CENTRAL PERMI7TINO OFFICEOF PASCO COUNTY Adwwwleyomont lulaw does not ImPb ocoopterwe of cancyrcencsc qid simply mceiplofa copy of tlila form,placing the�g psfmit owner on'=of M asseaement a1ld.the conaGns of payment for adme. DATE RECEIVED BY RECEIPT NO. DATE BY • w D Q Single Family Dwelling Plan Review Comments 1. F.F.E.. shall be a minimum of 8" above the road elevation and an engineered site plan. 2. Lots shall be graded to comply with R401.3 'of the F.B.C. 3. Compaction test required if 24" or more of fill dirt is brought in at any one.place. 4: Tie in survey required before pouring concrete. 5. Driveways require a R.O.W. use permit. All 4 sides of driveway thru the sidewalk shall have expansion material. 6! All setbacks shall be met. 7: All property markers shall be uncovered and marked at time of first inspection. 8: All A.D.A.--requirements shall be met: 9. No electric,plumbing, mechanical, or framing shall be covered without an inspection and approval first. 10. All Garages shall comply with section R302.6 of the F.B.-C. (Fire Separation). 1.1. Appliances shall not be installed in a location where subject to mechanical damage unless protected by approved barriers. M303.4 of the F.B.0 12. Water heaters shall comply with section P607.3 of the F.B.C. 13. Foundation supports for A/C units shall be raised at least 3" above finished grade. M1308.1. 14. Return air iri all bedrooms. F.B.-C. M1620A 1.5. Smoke detecto is.are to be installed in accordance with R313.1 of the F.B.C. 16.All glazing requirements are to be in accordance with R308.4 of the F.B.C. 17. All means of egress are to be in accordance with R311 of the F.B.C. 18. "Green gypsum board" shall riot be used as a backer in showers or tubs. R702A.2 F.B.C. 10. Combination-type AFCI breakers are.required at all locations requiring an AFCI type breaker-. 20. Carbon monoxide alarms will:be required in new construction that uses fossil-burning heating or appliances or an attached garage. They shall be installed in accordance with the F.B.C. 21. All plumbing,mechanical, and electrical shall be separate from unit to unit: This includes all underground plumbing and electric. 21 All 2016 N.-E.C. Codes will be enforced: 21 Tamper- Resistant.Receptacles in accordance with 406.11 of the 2016 N.E.0 24. In accordance with the Land Development Code, lots_ shall be sodded before final at least_ 10 feet around the structure. 25. R403.5.3Hot water pipe insulation insulation for hot water pipe with.a minimum thermal resistance (R-value) of R-3 shall be applied to the following: Piping 1,h inch (19.1 mm)and larger in nominal diameter, Piping serving more than.one dwelling unit. Piping located outside the conditioned space. Piping from the water heater to a distribution manifold. Piping.located under a floor slab. Buried in piping. Supply and return piping in recirculation systems other than demand recirculation systems. 25.Blower door test shall be provided.liefore' C.O; 26.A copy of the energy cacls shall be with permit at all times 27. Cope of rMaI'ihsulation-ieyort shalhbe provided with permit before fnaL 28. No fence, pool or screen-enclosure is-issued with this permit F.F.H.-Finished Floor Elevation F.B.C-.Florida Building Code 6ffi Edition R.O.W.-Right of Way A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code (2016) W �1'0 \ \ .f'r _ter" •� �. �''� �r" � .� � ! � 1 � -�3� •� �,.�I � "-,._ _ cn fi • _r p T[ f �l � /� f•' /��� /� ,�r f! CFn In -,a -r¢ •,\ � '�, o m � �,•F::tom �S �-�, ,s---- f` � '� `s r�-�_`- �-�� .l�.� l ' `'�`� '`���'�/ \ ��:,� ', �- �'�+,'' � �, � �n � y� � o ram- f I f°� y j' � •° � � �, •�\ co *\ :� ` rho ��f i'j. •' �j 7YV` 1 ` t 4a" W Irm- 4 C� " /J J t °,, ��., �' y '� �,+ j'F '"' '�• �*;'- ,t1� I C7 ;`+*tip, SKETCH ONLY SEC. 24 TWP. 26 S, RNG. 21 E. PLAT PLAN NOT A BOUNDARY SURVEY LOT 231 BEARING BASIS: HIDDEN RIVER PHASE 2 WEST BOUNDARY OF SUBJECT PLAT BEING N 0923'02" E PASCO COUNTY, FLORIDA. DO NOT SCALE THIS PRINT. DIMENSIONS AND PRELIMINARY DRAWING: ON LOT AREACALCULATIONS N NOTES TAKE PREFERENCE. THIS PLAN IS FOR PERMITTING PURPOSES LOT —6-600 APLSO. FT. ALL DATA SHOWN HEREON BASED ON THE ONLY, NOT FOR CONSTRUCTION. VERIFY LIVING AREA FT. '0 ENGINEERING PLANS OF KIMLEY—HORN AND ALL DIMENSIONS BEFORE ANY CONSTRUCTION. ENTRY FT. ASSOCIATES, INC., PROVIDED BY LENNAR HOMES. GARAGE 408---SQ. FT, LEGEND: COVERED LANAI _—_SO. FT, 10' PUBLIC UTILITY EASEMENT 2 ,L ---SQ. FT, — PROPOSED DRAINAGE FLOW PATIO --a. (00.00) = PROPOSED GRADE CONC. DRIVE =--A!!L---SQ. FT. E-00.00 = EXISTING GRADE A/C & CONC PAD =--!_____SO. FT. < PRIVATE SIDEWALK =--Zl----SQ. FT. NOTES: IMPERVIOUS + LOT GRADING TYPE = A =--Z!!22--SQ. FT. SOD =--iQLk---SQ. FT. PROPOSED PAD ELEVATION FRONT SETBACK = 20' OFF LOT AREA CALCULATIONS SIDE SETBACK = 10' RIGHT OF WAY FT. REAR SETBACK = 10' DRIVE APRON FT. PUBLIC SIDEWALK FT. SOD 33 L6----SQ. FT. TOTALS AREA FT. DRIVEWAY ---SQ. FT. SIDEWALK FT. SOD FT. a LOT 230 q b3 N CD ;p LOT 263 .0. 'a0�o ng ",o ;A ':S�k- '0 LOT 262 0. pp C> LOT 232 0 LOT 261 PROPOSED: LOWEST FLOOR ELEVATIONS: LIVING AREA: 72.50' GRAGE DESCRIPTION: ELAEVATIONSAREA: REFERENCED TO LOT 231, MAP OR PLAT ENTITLED "HIDDEN RIVER PHASE 2", NATIONAL GEODETIC VERTICAL AS RECORDED IN PLAT BOOK 079, PAGES 102 THROUGH DATUM* OF 1929. MEAN SEA 110, OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. LEVEL= 00.00 FT. APPARENT FLOOD HAZARD ZONE: X' COMMUNITY PANEL NO. 12101CO458F EFFECTIVE DATE: 09/26/2014 o T—Square Feet: . 6600.00 t LENNAR HOMES LEGEND: (C)= CALCULATED DATA, (D)= DEED DATA, (M)= MEASURED DATA, (P)=, PLAT DATA, q= CENTERLINE, A/C=_AIR CONDITIONER, B/C= BACK OF CURB, C/S= N CONCRETE SLAB, CH= CHORD, CHB= CHORD BEARING, CLF= CHAIN LINK FENCE, CONC= CONCRETE, COV.= COVERED, E/P= EDGE OF PAVEMENT, ESM'T= EASEMENT, F/C= FENCE CORNER, FCM- FOUND CONCRETE MONUMENT, FIP= FOUND IRON PIPE, FIR= FOUND IRON ROD, FN&D= FOUND NAIL & DISK, FPP= FOUND PINCHED PIPE, LFE= LOWEST FLOOR ELEVATION, MAS.= MASONRY, OR= OFFICIAL RECORD BOOK, PB= PLAT BOOK, PCP= PERMANENT CONTROL POINT, PRM= PERMANENT REFERENCE MONUMENT, R/W= RIGHT OF WAY, R= RADIUS, SIR=SET 1/2" IRON ROD & CAP No. 4493, SN&D= SET NAIL_& D!5K No.4493, TBM= TEMPORARY BENCHMARK, U/P= UTILITY POLE, W,/F= WOOD FENCE z Drawn By: JOHN R.BEACH&ASSOCIATES, INC. SMS SURVEYORS AND MAPPERS Checked By: 911 WEST ST. PETERSBURG DRIVE ONE OLDSMAR, FLORIDA 34677 WAY (813) 854-1276 FAX (813) 855-8370 Scale: 1.1=3o. NOT VALID WITHOUT ORIGINAL SIGNATURE Date: PLOT PLAN 9/21/2020 ACS AND SEAL OF A FLORIDA LICENSED SURVEYOR AND MAPPERtf - 7 1: Revisions: ,?rGNAT 9kF-1 N JOHN R. B H FLORIDA REG.)LAND 'SURVEYOR No.' 2984 LB#4493 PASCOCOUNTY Receipt Date: 04/091421 BUILDING CONSTRUCTION SERVICES Receipt Number: 9014461, PAS C 8731 Citizens-Drive I COUNTY FLoi (DAIW Suite,2'30 Om-tv SPACES.Vinibli-vi-PLAcEs. Now Pbrt Richey,FL 34654 1:5/9q,74 0�1 727-847-8126 NoT A. PERMIT `* Paid.13y Check# CC Auth# Cashier ID Workstation Check 01591456 MLARNOLD BCCCP47L Fed Descriptidn Amount Paid I mpad.Fee Residential Solid Waste,Single Family 50.58 Total.Payments: $50.58 Pavor Address Phone LENNAR ,Comments: -24-261-21w01 10-00660-2310 39673 HARVEST CREEK LANE While you Will be paying your bi h4lih Pasco County Building ConstructionServIcis,the full amouht of the credit card or e-check,feqs,NOT shown above,Is collected by First , Billing payment services. myreportslrepottq/lproductionIPA8COICustomer Receipt vlf.rpt Print bate: 04/09/2021 Page 1 of 1