Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
20-1157
D ioe City Of Zephyrhilis PERMIT;NUMSER l= 5335 Eighth Street k �< Zephyrhills, FL 33542 BGR-001157-2020 Phone: (813)780-0020 Fax: (813)780-0021 Issue Date: 12/16/2020 Permit Type: Building General (Residential) Property Number StreetAddress 14 26 210000 00200 0000 38022 Winters Dr Owner Information Permit Information Contractor-Information Name: KEYSTONE WINTERS LLC Permit Type:Building General(Residential) Contractor: FLA POOLS INC Class of Work:In Ground Swimming Pool Address: 17633 Gunn Hwy 335 Building Valuation:$106,000.00 ODESSA,FL 33556 Electrical Valuation:$5,500.00 Phone: (813)714-9610 Mechanical Valuation:$0.00 Plumbing Valuation:$10,500.00 Total Valuation:$122,000.00 % r� Total Fees:$1,080.0080.00 Amount Paid:$1,080.00 �J Date Paid:12/16/2020 10:02:21AM Project Description INSTALLATION POOL 20 X 50 .Application'Fees Electrical Permit Fee $67.50 Plumbing Plan Review Fee $46.25 Building Permit Fee $560.00 Plumbing Permit Fee $92.50 Building Plan Review Fee $280.00 Electrical Plan Review Fee $33.75 REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each subsequent reinspection. Notice: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permit required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner:Your failure,to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications add fee Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. M CONTRACTOR SIGNATURE PE IT OFFICE PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER Fla Pools INC . 1212 N. Parsons Ave,Brandon, FL 33510 Commercial&Residential 813-839-POOL (7665) Fax 813-835-SWIM(7946) I,Robert Sicignano Contractor License# CPC1457671 Hereby authorized the following to act as my agent(s) in obtaining permits in Dade City county of Zephyrhills,Florida. Emma Greene Currently authorized agent will remain on file. It is the responsibility of the License Holder to Notify this office or agent removal. License Holder's Signature 1 z•/G •Z al State of: County of. Before me,personally appeared, ��L-� r, - C>,who produced as identification or iOqi2a?,2020 o me, and who did affirm and subscribed before me this 1 Lp day of Signature of the Notary Affix Seal or Stamp I0 "� •; �D�oy ,n,fie - ,�: Name of Notary Typed, printed and stamped eOnded 1h�° �e,'QQ�� 1 gbh`u`�� � � My Commission Expires 3 23 www.flapools.com /info(a,flapools.com State Certified CPC1457671 CITY OF " " BUILDING ZEPHYRHILLSNOTICE DEPARTMENT OF ADDITION OR CORRECTION D • NOT REMOVE ADDRESS DATE PERMIT 3�0 P/- q�- / THIS JOB HAS NOT BEEN COMPLETED. The following additions or corrections shall be made before the job will be accepted. C 1���1r�y h l ��r� C• It is unlawful for any Carpenter,Contractor,Builder,or other persons,to AFTER CORRECTIONS ARE MADE CALL cover or cause to be covered,any part of the work with flooring,lath,earth or other material,until the proper inspector has had ample time to approve 780-0020 FOR RE-INSPECTION the installation. OFFICE HOURS 8:00 AM-4:30 PM MON.-FRI. INSPECTOR t*� DUKE ENERGY® WR#39034417 December 10,2020 Florida Pools emma@flapools.com Subject: 38022 WINTER DR Dear Florida Pools Thank you for contacting Duke Energy Florida, LLC for a letter of no conflict regarding your pool construction. NO CONFLICT: Duke Energy Florida,LLC has reviewed our existing facilities at the above referenced address and has found no apparent conflict at the proposed pool location. According to the drawing(s)you have provided Duke Energy Florida,LLC has no objection to the proposed fl construction. Note: Florida law requires excavators to dial Sunshine State One Call of Florida at 811 to locate existing underground utilities prior to digging to avoid personal injury and damage to equipment. Sincerely, Adrianna Caputo Project Coordinator Duke Energy Florida, LLC 4121 Saint Lawrence Dr,New Port Richey, FL 34653 1 1 City of ZephyrhilIs BUILDING PLAN REVIEW COMMENTS Contractor/Homeowner: Date Received: Site: oa� G-Xts 7 5)n- Permit Type: L ® Approved w/no comments:❑ Approved w/the below comments: Denied w/the below comments: ❑ b 2 (>r 001 C-4 Ifi- — iz-�yY: Ste-i �Lf ® C5 - -n k� Lf 514 Ec�,J_ MiLLIeflt 46 / c j L This comment sheet shall be kept with the permit and/or plans. Bil urgess--Buildig Official Date Contractor and/or Homeowner (Required when comments are present) t 813-7810-0020 City of Zephyrhilis Permit Application---- Fax- ,13-7s0-0o21 Building Department Date Received f 2- 2-Z /3 0 13 9 ` 1 ,� Phone Contact for Permitting € €€€€€€ EXIOEX213=Owner's Name Ke S+oAIE L.C Owner Phone Number rea - Owner's Address 3 83022 A I N TE;R i- Zoo' RK/ Owner Phone Number Fee Simple Titleholder Name Owner Phone Number Fee Simple Titleholder Add s Q 4 JOB ADDRESS ,$Ozz i4twrERS br ZePh r2H/i_c.S ' FL LOT#- oe SUBDIVISION & ?rgrFP s M l-t/" PARCEL ID# 14 '2 4- 2 1 - c © ©© - &0,9-© (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED NEW CONSTR ADD/ALT = SIGN = = DEMOLISH Pq INSTALL R. REPAIR PROPOSED USE = SFR Q COMM = OTHER TYPE OF CONSTRUCTION = BLOCK 0 FRAME = STEEL = DESCRIPTION OF WORK �Y / '��L E ?/9 yeg_ Ecl BUILDING SIZE C;�c , t o , SQ FOOTAGE /�vOd HEIGHT .LLL_LLLL.LE;LLLLLL'LLLkLL'L'LLEkIL LLLLLLLILLE;LLLLL'L' LL'LL'�ELLL3EL.L'LLL'L'LL"EL"L � EBUILDING POv/ $ VALUATION OF TOTAL CONSTRUCTION =ELECTRICAL $ I _9 06 o^ AMP SERVICE PROGRESS ENERGY = W.R.E.C. =PLUMBING $ I O �O�m ±ANNSTALLATION �h L� L C1 � B . $ VALUATION OF M =GAS = ROOFING 0 SPECIALTY .0 OTHER FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES NO _ BUILDER r� COMPANY l^4A T SIGNATURE REGISTERED �_ Y _N; E FEEURREt3— Address - z 12 /1/• PRR$ow-f/4✓r �R'19A D O1J License# CPC 14.6 ELECTRICIAN COMPANY CA SIGNATURE O REGISTERED N FEE CURREN Y/N Address �� /1���{�/€w //�' /1/y,-Rw/EV_J License# PLUMBER COMPANY rA / 00.4.S SAAC, SIGNATURE REGISTERED Y/N FEE CURREN Y/N . Address 12/z n4. PQ qso q5 xke /53R/J Dal✓ ?e:� License# MECHANICAL COMPANY SIGNATURE REGISTERED Y/N I FEE CURREN Y/N Address License# OTHER COMPANY SIGNATURE REGISTERED YIN FEE CURREN Y/N Address License# IEEIFI�i >FI[ItIEii €Il..ii.I€"I6IE-ICIE. IE [ i'I6IliIEtIIf: E.II €a,fE"E€[sIF11IEI[ Ea! >€ ti.[ If €.ti.I[1,11.i.IItlI 111I RESIDENTIAL Attach(2)Plot,Plans;(2)sets of Building Plans;(1)set'of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date.Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 durripster;Site Work Permit for subdivisions/large projects COMMERCIAL Attach-(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction. Minimum ten(10)working days.after submittal date.Required onsite,Construction Plans,Stormwater.Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. ****PROPERTY SURVEY,required for all NEW construction. Directions: Fill out application completely. Owner&Contractor sign back of application,notarized If over$2500,a Notice of-Commencement is required.(A/C upgrades over$7500) •' Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage) Driveways-Not over Counter if on public roadways..needs ROW 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department NOTICE OF DEED RESTRICTIONS:The undersigned understands that this permit may be subject to"deed"restrictions"which may be more restrictive than County regulations.The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES:If the owner has hired a contractor or contractors to undertake work,they may be required to be licensed in accordance with state and local regulations.If the contractor is not licensed as required by law,both the owner and contractor may be cited for a misdemeanor violation under state law.If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work,they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847-8009. Furthermore,if the owner has hired a contractor or contractors,he is advised to have the contractor(s)sign portions of the"contractor Block"of this application for which they will be responsible.If you,as the owner sign as the contractor,that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES:The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings,change of use in existing buildings,or expansion of existing buildings,as specified in Pasco County Ordinance number 89-07 and 90-07,as amended.The undersigned also understands,that such fees,as may be due,will be identified at the time of permitting.It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a"certificate of occupancy"or final power release.If the project does not involve a certificate of occupancy or final power release,the fees must be paid prior to permit issuance.Furthermore,if Pasco County Water/Sewer Impact fees are due,they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713,Florida Statutes,as amended):If valuation of work is$2,500.00 or more,I certify that I,the applicant, have been provided with a copy of the"Florida Construction Lien Law—Homeowner's Protection Guide"prepared by the Florida Department of Agriculture and Consumer Affairs.If the applicant is someone other than the"owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner"prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction,zoning and land development.Application is hereby made to obtain a permit to do work and installation as indicated.I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction,County and City codes,zoning regulations,and land development regulations in the jurisdiction.I also certify that I understand that the regulations of other government agencies may apply to the intended work,and that it is my responsibility to identify what actions I must take to be in compliance.Such agencies include but are not limited to: Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands,Water/Wastewater Treatment. Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. Army Corps of Engineers-Seawalls, Docks, Navigable Waterways. Department of Health $ Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. US Environmental Protection Agency-Asbestos abatement. Federal Aviation Authority-Runways. I understand that the following restrictions apply to the use of fill: - Use of fill is not allowed in Flood Zone"V'unless expressly permitted. - If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume" will be submitted at time of permitting which'is prepared by a professional engineer licensed by the State of Florida. - If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction, I certify that fill will be used only to fill the area within the stem wall. - If fill material is to be used in-any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill, an engineered drainage plan is required. If I am the AGENT FOR THE OWNER,I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction.I understand that a separate permit may be required for electrical work,plumbing,signs,.wells,pools,air conditioning,gas,or other installations not specifically included in the application.A permit issued shall be construed to be a license to proceed with the work and not as authority to violate,cancel,alter,or set aside any provisions of the technical codes,nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans,construction or violations of any codes.Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance,or if work authorized by the permit is suspended or abandoned for a period of six(6)months after the time the work is commenced.An extension may be requested,in writing,from the Building Official for a period not to exceed ninety(90)days and will demonstrate justifiable cause for the extension.If work ceases for ninety(90)consecutive days,the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT, FLORIDA JURAT(F.S. 117.03 OWNER OR AGENT 1 o CONTRACTOR Subscribed and swom to(or affirmed)before me this Subscribed and sw to(or affirmed before me this by by r 1✓ I U Who 1p/are personally known to me or has/have produced Who is/are personally known tome or has/h a produced S as identification. as identification. /l /� 1 Notary Public ( Notary Public Commission No.C C4A�trN Commission No. fls� 1 ?_�,o Gov l ry.l i Z V,4A'P— I fbn QQ V i Iv )T 2 Name of Notary typed,printed or stamped Name of Notary typed,printed or stamped \`��a�uulurryr� \`����111uurrNrr�i %gpDOV/iy���ii��i SODO�jN� W GH23,2 / i p� GH23, i oW 972417 #GG 972417 1 �01'�/dyp�nded«e c��•�Q �'y�,, ;�?e�nded�h�° �sp.�•�&D tic Und �.��� �i"rY �bkc UrAt O ��� ''''''fi r 11 SI O'\ Fla Pools' INC . 1212 N. Parsons Ave, Brandon, FL 33510 Commercial&Residential 813-839-POOL (7665) Fax 813-835-SWIM M46) I, Robert Sicignano Contractor License# CPC1457671 Hereby authorized the following to act as my agent (s) in obtaining permits in Dade City county of ZephyrhiIis, Florida. ArNOM =G tGk)A110 J06 j ,n H; C-A\ Alv id 1)A I-i- l4ex r e Currently authorized agent will remain on file. It is the responsibility of the License Holder to Notify this office or agent removal. License.Holder's Signature' Date 1 -° State of FjorCt V Q" County of. 11 40-6 Y Before me,personally appeared, T���`�� � L"�'�`�'"�``� , who produced as identification or is personally known to me, and who did affirm and subscribed before me this t day of tloV ,2020 Signature of the Notary Affix Seal or Stamp \\\\`\���t��BQDQ����///��� �� 0 sslo RGN2Jz�or•. iK 10 Do y { M k *: ? Name of Notary Typed,printed and stamped 99G 972417 eO�ded �1 ��� My.Commission Expires "LL4� 11 to www.flapools.com/ info(a7flapools.com State Certified CPC1457671 INSTR#20201962G4 OR BK 10218 PG 2926 Page 1 of 1 11/18/2020 02:27 PM Rcpt:2228611 Rec:10.00 DS:0.00 IT:0.00 re Nikki Alvaz-Sowles,Esq.,Pasco County Clerk&Comptroller Permit No. Parcel ID No f- NOTICE OF COMMENCEMENT State of F�02,Dia County of a19 5 c 0 THE UNDERSIGNED hereby gives notice that Improvement will be made to certain real property,and In accordance with Chapter 713,Florida Statutes,- the following Information Is provided in this Notice of Commencement 1. Description of Property: Parcel Identiticallon No. 2/ ©.0 n B 0 C 9 2,.®0 O n e`J Street Address: 3 SD?-2 ill N TER- D r- Ze a A r, h,,//s. FL 2. General Description of Improvement 7'r O/^b/ r7 c re. e oori/ With Day".r-dedect- 3. Owner Inforrmation or Lessee Information If the Lessee contracted for the Improvement: 38°0 .me 11 Y[r r' AIFIt's Address Cily —V state Interest In Property: N s Name of Fee Simple Titleholder. (if different from Owner listed above) a U Address pp--� City State rn cc) 0- � U Q 4. Contrector. rI-A '!!��00"SANG Name ro E 4= — 04 /Z17 Al. PARSQA/S Aux- J�ltc�ndon m (D s Address /� / Gty State u�0 Contrector's Telephone No.: �� �3 7 (O �, 'c) .- i6� V � o 5. Surety o p o W Name a Co Address City State o ro Qr Amount of Bond:E Telephone No.: 4 o 0 LL` 6. Lender. G � L - 0 }' Name o .� Ucs Address City State c 0tu� a �o Lenders Telephone No.: -0- 7. Persons within the State of Florida designated by the owner upon whom notices or other documents may be served as provided by ta`8 t- Section 713.13(1)(a)(7),Florida Statutes: Name Address City State Telephone Number of Designated Person: V S. In addition to himself,the owner designates of— to receive a copy of the Llenor's Notice as provided in Section 713.13(1)(b),Florida Statutes. Telephone Number of Person or Entity Designated by Owner. h V co 9. Expiration date of Notice of Commencement(the expiration date may not be before the completion of construction and final payment to the . O contractor,but will be one year from the date of recording unless a differenfdate Is specified): O WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT • e ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13 FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICEr OF COMMENCEMENT MUST BE tt__ RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING,CONSULT "7 WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. '��• • Under penalty of per)ury,I declare that 1 have read the foregoing notice of commencement and that the facts stated therein are true to the best of my knowledge and belief. STATE OF FLORIDA COUNTY OF PASCO S gnature of Owner o e,Or Owners or Lessee's Authorized Officer/Dlrector/Partner/Manager Signatorys TItI The foregoing Instrument was acknowledged before me this L1 day of ; Y .2oekly � �1 as HARtto't/- (type of authority.e.g.,Wee, Bomey in tact)for (na partygn beha s executed). Personalty Known O 2B Produced IdentHicagn V Notary Signatu►r/@ t11111U Type of Identification Produced %tf M A"*-; Name(Print) �(aYl ���� - a���� "•� Ty��i�� • �:yam";i170972�17. •• �l wpdataf cslnoUcecommenoemenLpc053048 HISItNNN PRIVATE SWIMMING POOLS AND SPAS REQUIRED INFORMATION FOR INSPECTIONS AND POOL APPLICATIONS FLORIDA BUILDING CODE 2017, CHAPTER R4501 Pasco County requires the following information to process applications for private swimming pools. Applicants are required to provide a pool layout showing: 1. The pool with a complete plumbing plan showing the location of the mechanical equipment and the plumbing lines, vent lines, pipe sizes, flow rates, and pressures. 2. The layout of the pool with dimensions showing steps, swimouts, ladders, and other features. 3. The spa with a plumbing plan. 4. The deck with dimension showing relationship to the house. 5. Location of windows and doors that have access to the pool from the house. 6. The location of the child barrier fence. Applicants are required to provide the following information: 1. Pool volume: 3011 N gallons 2.. Pump Mfg.: . T 'h 1-61 j r Model No.: 0-,- Yb Turnover Rate: GPM HP.: V 3. Filter Mfg.: C lPah 4 Q16A '+ccj09zu Model No.: l; Zl'7 Flow Rate:GPM 4. Pool Heater Mfg.: 2.e Vj-jn)lr MWy' m(2 L'DDkodel No.: WOO 5. Anti-Vortex Covers Mfg.: (-VIAA S-i-Ci.r'' 12-110V Model No.: 1 Z 11V y� Applicants are required to provide design drawings showing pool and spa requirements designed to meet the Florida Building Code 2017, with any supplements, certified by a Florida registered engineer or architect. The applicant shall provide two copies of all the above information. This information shall be supplemental to the normal permitting materials necessary at intake. RESIDENTIAL SWIMMING POOL, SPA, AND/OR HOT TUB SAFETY ACT NOTICE OF REQUIREMENTS I (We) acknowledge that a new swimming pool, spa, or hot tub will be constructed or installed at (please print street address) nU21 w0oigit F1, 335 LI2— and hereby affirm that one of the following methods will be used to meet ter uirements of Florida Statutes (F.S.) 515: Please initial the method(s)to be used for your pool. _ The pool will be isolated from access to the home by an enclosure that meets the pool barrier requirements of F.S. 515.29. The pool will be equipped with an approved, safety-pool cover that complies with ASTM F1346-91 (Standard Performance Specifications for Safety Covers for Swimming Pools, Spas, and Hot Tubs). All doors and windows providing direct access from the home to the pool and located within the enclosure/fence required by the Pasco-County Land Development Code (LDC), Section 530.4(D), will be equipped with an exit alarm that has a minimum sound pressure rating of 85 decibels at ten feet. All doors providing direct access from the home to the pool and located within the enclosure/fence required by the Pasco County LDC, Section 530.4(D),will be equipped with self-closing, self-latching devices with release mechanisms placed no lower than 54 inches above the floor or deck. In addition to the enclosure/fence required by the Pasco County LDC, Section 530.4 (D), a swimming pool alarm that,when placed in a pool, sounds an alarm upon detection of an accidental or unauthorized entrance into the water. Such pool alarm must meet and be independently certified to ASTM Standard F2208, titled "Standard Safety Specification for Residential Pool Alarms," which includes surface motion, pressure, sonar, laser, and infrared alarms. For purposes of this paragraph, the term "swimming pool alarm" does not include any swimming protection alarm device designed for individual use, such as an alarm attached to a child that sounds when the child exceeds a certain distance or becomes submerged in water. I UNDERSTAND AND AGREE THAT NOT HAVING AT LEAST ONE OF THE ABOVE INSTALLED AT THE TIME OF FINAL INSPECTION OR WHEN THE POOL IS COMPLETED FOR CONTRACT PURPOSES WILL CONSTITUTE A VIOLATION OF F.S. 515, AND WILL BE CONSIDERED AS COMMITTING A MISDEMEANOR OF THE SECOND DEGREE, PUNISHABLE BY FINES UP TO $500.00 AND/OR UP TO 60 DAYS IN JAIL AS ESTABLISHED IN F.S. 775. R4501.17.1.10: Where an aboveground pool structure is used as a barrier or where the barrier is mounted on top of the pool structure and the means of access is a ladder or steps, the ladder or steps shall either be capable of being secure, locked, or removed to prevent access, or the ladder or steps shall be surrounded by a barrier which meets the requirements of R4501.17.1.1 through R4501.17.19 and R4501.17.12 through R4501.17.14. When the ladder or steps are secured, locked, or removed, any opening created shall not allow the passage of a four-inch diameter sphere. I FURTHER UNDERSTAND AND AGREE THAT THE OWNER AND/OR CONTRACTOR WILL COMPLY WITH THE FOLLOWING REGULATIONS CONCERNING SWIMMING POOL, SPA, AND/OR HOT TUB ENCLOSURES IMMEDIATELY UPON COMPLETION OF THE SWIMMING POOL, SPA, OR HOT TUB, IN COMPLIANCE WITH THE PASCO COUNTY LDC, SECTION 530.4(D): 1. Construct around the swimming pool, spa, or hot tub a MINIMUM FOUR-FOOT-HIGH FENCE with self-closing, self-latching gates. The fence must not have any gaps, openings, indentations, protrusions, or structural components that could allow a young child to crawl under, squeeze through, or climb over the fence. Gates must open outward, away from the pool area. The releasing mechanism of the latching device must be located on the pool side of the gate and so placed that it cannot be reached by a young child over the top or through any opening or gap. No opening in the fence may be large enough to admit a four-inch sphere. 2. Construct a screen enclosure around the swimming pool, spa, or hot tub with self-closing, self-latching, screen doors. Latches on exterior, screen doors must be a minimum of 54 inches from the exterior access standing surface. All screen enclosures require Building Permits. SWORN AND SUBSCRIBED BEFORE ME THIS DAY OF 20)b OWNS OR CONTRACTOR SIGNATURE TO yvi Ba I/ vk-a'tf NOTARY PUBLIC PLEASE TYPE OR PRINT NAME�BOVE Natwy PuW Sift of Fiwda ROBERT SICIGNANO My CommWion GG 9W793 Exkft05rAV2024 --RESIBENTLAA,SWIMMING POOL, SPA, AND/OR HOT TUB SAFETY ACT NOTICE OF REQUIREMENTS I (We) acknowledge that a new swimming pool, spa, or hot tub will be constructed or installed at (please print street address) aU 1;J { { Y ! q25 LI 2- and hereby affirm that one of the following methods will be used to meet ter uirements of Florida Statutes (F.S.) 515: Please initial the method(s)to be used for your pool. The pool will be isolated from access to the home by an enclosure that meets the pool barrier requirements of F.S. 515.29. The pool will be equipped with an approved, safety-pool cover that complies with ASTM F1346-91 (Standard Performance Specifications for Safety Covers for Swimming Pools, Spas, and Hot Tubs). All doors and windows providing direct access from the home to the pool and located within the enclosure/fence required by the Pasco-County Land Development Code (LDC), Section 530.4(D), will be . equipped with an exit alarm that has a minimum sound pressure rating of 85 decibels at ten feet. All doors providing direct access from the home to the pool and located within the enclosure/fence required by the Pasco County LDC, Section 530.4(D),will be equipped with self-closing, self-latching devices with release mechanisms placed no lower than 54 inches above the floor or deck. 1 In addition to the enclosure/fence required by the Pasco County LDC, Section 530.4 (D), a swimming pool alarm that, when placed in a pool, sounds an alarm upon detection of an accidental or unauthorized entrance into the water. Such pool alarm must meet and be independently certified to ASTM Standard F2208, titled "Standard Safety Specification for Residential Pool Alarms,"which includes surface motion, pressure, sonar, laser, and infrared alarms. For purposes of this paragraph, the term "swimming pool alarm" does not include any swimming protection alarm device designed for individual use, such as an alarm attached to a child that sounds when the child exceeds a certain distance or becomes submerged in water. I UNDERSTAND AND AGREE THAT NOT HAVING AT LEAST ONE OF THE ABOVE INSTALLED AT THE TIME OF FINAL INSPECTION OR WHEN THE POOL IS COMPLETED FOR CONTRACT PURPOSES WILL CONSTITUTE A VIOLATION OF F.S. 515, AND WILL BE CONSIDERED AS COMMITTING A MISDEMEANOR OF THE SECOND DEGREE, PUNISHABLE BY FINES UP TO $500.00 AND/OR UP TO 60 DAYS IN JAIL AS ESTABLISHED IN F.S. 775. R4501.17.1.10: Where an aboveground pool structure is used as a barrier or where the barrier is mounted on top of the pool structure and the means of access is a ladder or steps, the ladder or steps shall either be capable of being secure, locked, or removed to prevent access, or the ladder or steps shall be surrounded by a barrier which meets the requirements of R4501.17.1.1 through R4501.17.19 and R4501.17.12 through R4501.17.14. When the ladder or steps are secured, locked, or removed, any opening created shall not allow the passage of a four-inch diameter sphere. I FURTHER UNDERSTAND AND AGREE THAT THE OWNER AND/OR CONTRACTOR WILL COMPLY WITH THE FOLLOWING' REGULATIONS CONCERNING SWIMMING POOL, SPA, AND/OR HOT TUB ENCLOSURES IMMEDIATELY UPON COMPLETION OF THE SWIMMING POOL, SPA, OR HOT TUB, IN COMPLIANCE WITH THE PASCO COUNTY LDC, SECTION 530.4(D): 1. Construct around the swimming pool, spa, or hot tub a MINIMUM FOUR-FOOT-HIGH FENCE with self-closing, self-latching gates. The fence must not have any gaps, openings, indentations, protrusions, or structural components that could allow a young child to crawl under, squeeze through, or climb over the fence. Gates must open outward, away from the pool area. The releasing mechanism of the latching device must be located on the pool side of the gate and so placed that it cannot be reached by a young child over the top or through any opening or gap. No opening in the fence may be large enough to admit a four-inch sphere. 2. Construct a screen enclosure around the swimming pool, spa, or hot tub with self-closing, self-latching, screen doors. Latches on exterior, screen doors must be a minimum of 54 inches from the exterior access standing surface. ,Ali screen enclosures require Building Permits. SWORN AND SUBSCRIBED BEFORE ME THIS DAY OF Af,),f4 20,/\O OWNEWOR CONTRACTOR SIGNATURE NOTARY PUBLIC PLEASE TYPE OR PRINT NAME"ABOVE YNatwy Public Stet at FWda ROBERT SICIGNANO 0' 953793 ou MCWu=jf