HomeMy WebLinkAbout20-1166 Ffi0f11UH City Of ZephyrhillS LLB„ PERMIT NUMBER
5335 Eighth Streetµ ,
-= Zephyrhills, FL 33542 ELCMISC-001166-2020
Phone: (813)780-0020
Fax: (813)780-0021 Issue Date: 12/17/2020
i t
Permit Type: Electric Service Replacement/Misc
Property Nurriber -Street`Add'cess° :gin,77
:
03 26 21 0160 00000 0810 6819 Stephens Path
Owner�flnfortnatwn .` Permit Information Conga or In"formation "4-
Name: VIVIAN DELGADO ERNESTO Permit Type:Electric Service Replacement/M Contractor: FLORIDA POWER
ARAUJO Class of Work:Add/Alter Residential MANAGEMENT
Address: 6819 Stephen Path Building Valuation:$0.00
ZEPHYRHILLS,FL 33542 Electrical Valuation:$35,784.00
Phone: Mechanical Valuation:
Plumbing Valuation: \ /�
Total Valuation:$35,784.00
Total Fees:$328.38 �✓
Amount Paid:$328.38
Date Paid:12/17/2020 1:27:23PM
I?rofect`Description
INSTALLATION ROOF MOUNT PV SOLAR
Electrical Plan Review Fee $109.46 Electrical Permit Fee $218.92
REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c)the
local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or
first reinspection,whichever is greater,for each subsequent reinspection.
Notice: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that
may be found in the public records of this county, and there may be additional permit required from other governmental
entities such as water management, state agencies or federal agencies.
"Warning to owner:Your failure to record a notice of commencement may result in your paying twice for
improvements to your property. If you intend to obtain financing,consult with your lender or an attorney
before recording your notice of commencement."
Complete Plans,Specifications add fee Must Accompany Application.All work shall be performed in
accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O.
NO OCCUPANCY BEFORE C.O.
CO CTOR SIGNATURE PEf IT OFFICE
PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION
CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED
PROTECT CARD FROM WEATHER
Florida Patter M nagp:nerit
1331Green Forest Ct
Unit 3
FLORID _ :.: WER Winter Carden.FL 34787
Ems} A' N A G`°E.,,`>� E -N T
Phone:(407)554-2047
ftoridapomrmanagernenLcorn
EC1300854
May 21,2020
To Whom it may concern,
I authorize Nicole Wallace to act as the permit runner for Florida Power Management. She is
authorizer to drop off, pickup and pay for perrilits and may make any mirror corrections to permit
apes as needed.
Thank you,
Richard Lon g .!o'R.
License Holder
Ngtay PugiiC Sk�;o of FIOriCp
Niaoie 8yington
4r�1 � < lJ.y Commis titm GG 927579
'ar nod Exprns'SU�2912g23
2,1 � a20
stk6sc rt 6 m� : P ja; P►rA Uvm,)a Sr.
813-780.0020 City of Zephyrhills Permit Application Fax-813-700-0021
Building Department
Date Ro%Wed - J T
Phone Contact for Permitting[a
Owner's Nam. VivianJ at[
'Delgado Owner Phone Number 813 440-8145
owner's Address Eii7STEPHENSOwner Phone Number
Fee Simple Titleholder Name Owner Phone Number
Fee Simpla Titleholder Address
JOB ADDRESS 1 6819 STEPHENS PATH LOT III 81
SUBofV,S,ONSte ens en at i V r `1SLtoq 03-26-21-0160-00000-0810
(OBTAINED FROM PROPERTY TAR NOTICE)
WORK PROPOSED B NEW CONSTR 8 ADD/ALT = SIGN = = DEMOLISH
INSTALL REPAIR
PROPOSED USE = SFR Q COMM 0 OTHER
TYPE OF CONSTRUCTION BLOCK FRAME = STEEL
DESCRIPTION OF WORK Foof mounted PV solar
BUILDING SIZE SO FOOTAGE HEIGHT
'CCCCCL"CCCCCCS"C'CCCCCCCRZTCC['C4"CLZ"CCC'R'CCCCC CCC'CCCL�CCCCCCr,
=BUILDING $ VALUATION OF TOTAL CONSTRUCTION 35784
=ELECTRICAL $ AMP SERVICEMPROG,yRESS/pEJNERGY Q W.R.E.C.
=PLUMBING $ n
=MECHANICAL s VALUATION OF MECHANICAL INSTALLATION f
=GAS = ROOFING Q SPECIALTY = OTHER
FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES NO LF`
BUILDER COMPANY
SIGNATURE REGISTERED I Y/N FEE CURREN Y/N
Address y� License q
ELECTRICIAN O ANY V Y, . G �O�Y
SIGNATURE IS RED /N /FEE CURREN Y/N
Address License#
PLUMBER COMPANY
SIGNATURE REGISTERED Y/N I FEECU Y/N
Address License If
4ECHANICALF COMPANY'
fGNATURE REGISTERED YIN FEE CURREN Y/N
Address License it
OTHER COMPANY
SIGNATURE REGISTERED Y/N FEE CURREN Y/N
Address License q
IIII.ItItltilttl.tltltltttt[t[[{t[tl[lit[l[I[[1l[tlltll11tt11111f11ttt
RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction,
Minimum ten(10)working days after submittal dale.Required onsile,Construction Plans,Slornwater Plans w/Sill Fence installed,
Sanitary Facilities&1 dumpsler,Site Work Permit for subdivisions/large projects
COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction.
Minimum len'(10)working days after submittal date.Required onsite,Construction Plans,Stornwater Plans w/Silt Fence installed,
Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance
SIGN PERMIT Attach(2)sets of Engineered Plans.
*—PROPERTY SURVEY required for all NEW construction.
Directions:
Fig out application completely.
Owner&Contractor sign back of application,notarized
If over$2500,a Notico of Commonaement Is required.(A/C upgrades over$75(10)
Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same
OVER THE COUNTER PERMITTING (copy of contract required)
Reroofs if shingles Sowers Service Upgrades A/C Fences(Plot/SurveylFootage)
Driveways-Nat over Counter if on public roadways..needs ROW
813.780.0020 City of Zephyrhills Permit Application Fox-813.780-0021
Building Department
NOTICE OF DEED RESTRICTIONS:The undersigned understands that this peril may be subject to'deed'restrictions'which may be more restrictive
than County regulations.The undersigned assumes resporisbiliity for compliance with any applicable deed restrictions.
UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES:If the owner has hired a contractor or contractors to undertake work,they
may be required to be licensed in accordance with state and local regulations.If the contractor is not licensed as required by law,both the owner and
contractor may be tiled for a misdemeanor violation understate law.If the owner or intended contractor are uncertain as to what licensing requirements
may apply.for the intended work,they are advised to contact the Pasco County Building Inspection Division—Llcensing Section at 727-847-8009.,
Furthermore,it the owner has tilted a contractor or contractors,he is advised to have the contrectogs)sign portions of the-contractor Block-of this
application for which theywill be responsible.If you,as the owner sign as the contractor•that may be an indication that he is not properly licensed and is
not entitled to permitting privileges in Pasco County.
TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY-FEES:The undersigned understands
[hat Transportation Impact Foes and Recourse Recovery Fees may apply to the construction of new buildings;change of use in existing buildings,or
expansion of existing buildings,as specified in Pasco County Ordinance number 89.07 and 90-07,as amended.The undersigned also understands,Thal
such fees,as may be due,will be identified at the time of permitting.It is further understood that Transportation Impact Fees and Resource Recovery
Fees must be paid prior to receiving a'cerfificate of occupancy"or final power release.If the project does not involve a certificate of occupancy or final
power release,the fees must be paid prior to peril issuance.Furthermore.if Pasco County Water/Sewer Impact fees are duo,they must be paid prior
to peril issuance in accordance with applicable Pasco County ordinances.
CONSTRUCTION LIEN LAW(Chapter 713,Florida Statutes,as amended):If valuation of work is$2,500.00 or more,I certify that 1,the applicant,
have been provided with a copy of the'Florida Construction Lien Law—Homeowners Protection Guide prepared by the Florida Department of
Agriculture and Consumer Affairs.If the applicant is someone other than the'owner,I certify that I have obtained a copy of the above described
document and promise in good faith to deliver it to[he'owner prior to commencement.
CONTRACTOR'SIOWNER'S AFFIDAVIT:I certify that all the information in this application is accurate and that all work will be done In compliance with
all applicable laws regulating construction,zoning and land development.Application is hereby made to obtain a permit to do work and installation as
Indicated.1 certify that no work or installation has commenced prior to issuance of a peril and that all work will be performed to meet standards of all
laws regulating construction,County and City codes,zoning regulations•and land development regulations in the jurisdiction.I also certify.that I
understand that the regulations of other government agencies may apply to the intended work,and that it is my responsibility to Identify what actions I
must lake to bain compliance.Such agencies include but are not limited to:
Department of Environmental Protection,Cypress Bayheads,Weiland Areas and Environmentally Sensitive
Lands,Water/Wastewater Treatment.
Southwest Florida Water Management District-Wells, Cypress Bayheads, Weiland Areas, Altering
Watercourses.
Army Corps of Engineers-Seawalls,Docks,Navigable Waterways.
Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment,
Septic Tanks.
US Environmental Protection Agency-Asbestos abatement.
Federal Aviation Authority-Runways.
I understand that the following restrictions apply to the use of rill:
Use of fill is not allowed in Flood Zone'V"unless expressly permitted.
If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a
"compensating volume"will be submitted at time of permitting which is prepared by a professional engineer
licensed by the Slate of Florida.
If the fill material is to be used in Flood Zone"A" in connection with a permitted building using stem wall
construction,I certify that fill will be used only to fill the area within the stem wall.
If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent
properties. If use of fill is found to adversely-affect adjacent properties,the owner may be cited for violating
the conditions of the building permit issued under the attached permit application,for lots less than one(1)
acre which are elevated by fill,an engineered drainage plan is required.
If I am the AGENT FOR THE OWNER.I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to
commencing construction.I understand that a separate peril may be required for electrical work,plumbing,signs,wells,pools,air conditioning,gas,or
other Installations not specifically included In the application.A peril issued shall be construed to be a license to proceed with the work and not as
authority to violate•cancel,alter,or set aside any provisions of the technical codes•nor shall issuance of a permit prevent the Building Official from
thereafter requiring a correction of errors in plans,construction or violations of any codes.Every permit issued shall become invalid unless the work
authorized by such permit is commenced within six months of permit Issuance,or if work authorized by the permit is suspended or abandoned for a
period of six(8)months after the time the work is commenced.An extension may be requested•in writing,from the Building Official for a period not to
exceed ninety(90)days and will demonstrate justifiable cause for the extension.If work ceases forninely(90)consecutive days,the job Is considered
abandoned.
WARNING TO OWNER:YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR
PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY.IF YOU INTEND TO OBTAIN FINANCING,CONSULT
WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT,
FLORIDA JURAT(F.S.117.03) -
OWNER ORAGENT CONTRACTOR " Q
Subscribed and sworn to(or affirmed)before me this Subscribed and swo to for affirmed beta .me this f'
by (tAMA
Who islare personally known to me or hasihave produced he Ware a on y known to me or has avelroduced
as identification. as identification.
Notary Public Notary Public
Commission No. mmission No. 61 ar
Name of Notary typed•printed or stamped Name of Notary typed,printed or stamped
Notary Public State of Florida
Matthew LeStarge
My tom
mission GG Expires 04 09/2022 205154
INSTR#2020192537 OR BK 10215 PG 978 Page 1 of 1
11/16/2020-09:11 AM Rcpt•.2226490 Roe:10.00 DS:0.00 IT:0.00
Nikki AlvarezSowles,Esq.,Pasco County Clerk&Comptroller
7%spate for neeby C7crL of 11x cvrnit Court ody.
NOTICE OF COMMENCEMENT
Parnil Numha: '
Twt Folio No.•b &o—oo0oo —oeto
Tie ondertlg.ed hmby Siw oodtc lint lwpruvammb will be raaae to ecrwn r I Properly,tied In aceordmmee eNb Settim 70.13 of the
Rend-St t ftl.the following infarmadou Is pro.rdal in the NOLLT1'1('E OF MMMENCEMI.".
1. I.cgtd Ika<Tiptiun ofpropeay(wwtaddras regvitcd):JT2 p�l�h�i �1 eh a t.Sl Iy2r �/{4/e 31 PC,;
F L 2
�33
2. ('-eneraldeaecioondlimproxe mu:_F.D Qu{7�e( Pv-"!( �Qr ._
31, 0111.Nanw V V t a ��--p�..,,}l1'1 eiS�Ya �Q !—
Crum=Addtess:-6 �5� 2k1.�C1.CJh, tT!c lt IFL
3b. OAnla's intact in site:A01t41h 6I'
3c. Fee Simple Title holder(ofodne;amv%voa)
Address: _�,.J,,, }�
4. contraaor xatne: Flo�rJ_�t�1dp-tL�..�o_1�.tey a
Addre56: �GEliYw7J!—SGY ( - 7 Nmnc.:A-O.L.�L4 �
S. Surely meant of 6Oad: �_�--
Addrex:_._�-. Phone: _
2 Le nla Narria— ---- contact -�
7. Pason Aithia the State of Florida daienated by owna Wi wltnm ootfces cr otber doatnxnts tray be smcd as psovid,-d by
Section 113.I3(IXA)7.Hiinda Statnres
Name: Addrm,- _.,
PlRme Number
R. In addition to himself.(Tuner desiprows the fo00w7ng person to receive a copy of the Llellor%Noti(c ns providw m Section
713.1 30)(b),Florida Sraanes.
Addn:x;Phone Nunftr. _
9- Expiration dax of Notice of Co movocaneat(espicntim date is me(I)year from date of recording unlee:t a different dete is —
specified).
WARNTNCTOOANER:ANY PAYTtE.YISMAOEU"IEOV'?MRAFft:RTIIEL[PIRATIONOFT1tEKOTILZIWCCMTMEWV.hIt TARL
CONSIDERED LiIMOPEti PAYatENTS UNLER C1tAPTTR 7O1.CART I.SECIIfAY J1,Ytr,A7DR1M STATLTT$ANR CAN RMILY M vORR
PAMIS TAT(4 FOR MPROYEAIENTSTO YOUR PROPERTY.A KOTI[R or t:/)mmEKr.Emm-r MUST RE RFr ORn1.D AND POSTED(kN 7jO:
JOR SrI'E BEFORE 71i[FTRCT fYSI'F;CITOV-IF YOU INRGYO TOONTAIK FIKANMC CO11$UI.TATrt1 Y(RIR I3WOER OR AN.\TT()<MT\'
REPOItE COAME.Y[IKI:WORK OR RECORDLYG YOUR NOTI('E P(T)AUNENCP3fEM.
Si�ttture oC LcaS,e,a Uwvcr's or).essec's Authotiztd 0(fitrrlDirectollPortnerManager
Sigattary"s TrtlNOftict
STATE OF FWRIDA
COUNTY OF f CISC.0
Tlx`f�..1�`oL�tQ u tupncwhd lwdure Inc dx.1_.&Y of l V OVI''NL 0Y r
hy �r�JO_—=�--- — -----fa--- - ----
�etsunaay Etnlwn O[[Nii RoCawd Identificat�o _ M
�TYR
�sdr N018rY Public State of Flonele
MDOle Byiflgton
a MY CMIMM +on GG 92757E�iO1�t EmmsTtA'nrm:i j.
U"de I J .• that the fa(as pnu 1 in u ate true w the xal of knowlcd5c acd bclieY
\X _
Si=tmurc of N ores{ ,ep Signing Above —_�-
U�cy-<frnytra.w.4 rWr•1 KPCw+r ai rnvBrn�Koir not;!a�['amrptCpvll UtWen rPIV YNI1
1
GODWIN ENGINEERING AND DESIGN, LLC
8378 Foxtail Loop,Pensacola,FL 32526 1 (850)712-4219 chad(@godwineng.com
October 28, 2020
To: Zephyrhills Building Department
5335 8th St.
Zephyrhills, FL 33542
Re: Delgado-Residential PV Roof Mount Installation
6819 Stephens Path
Zephyrhills, FL 33542
Plan Reviewer,
This letter is regarding the installation of a new roof mounted Solar PV System on the existing
residential structure at the address above.I have reviewed the attachment plan and have
determined that the roof mounted PV system is in compliance with the applicable sections of the
following Codes as amended and adopted by the jurisdiction:
2017 Florida Building Code 6th Edition,FBC
ASCE 7 Min.Design Loads for Buildings&Other Structures
Per 2017 FBC,the Roof Mounted PV system will be subject to the following design criteria:
Design Wind Speed(V„It) - 140mph 3sec gust, Exposure Category-B
The PV System consist of the modules,railing,and connection hardware.The system will add a
dead load of approximately 3 psf to the roof.
The existing roof covering is Asphalt Shingle with min.1/z"plywood decking and 2"x 4"roof trusses
24" O.C. The roofing,decking,and roof trusses are in good condition.The existing structure will be
adequate for supporting the additional PV dead load and wind loads.
The securement method of the PV system is to be flush mounted to the asphalt shingle roof with the
Quickmount Q-rail Light railing and the Sunmodo Nano Mounts.The attachments can be attached
up to 48"apart.The mounts should be staggered,where possible,to allow distribution of the design
loads evenly to the structure.The mounts shall be installed with a min.5/16"lag screw with
minimum 2-5/16"thread length.
Please see attached documents and contact me should you have any questions.
Sincerely,
D.Chad Godwin,PE 81360 \ ��1111I1►I//�,,
Exp. 02/28/2021 \���\'- lE C.
81 Z
d 1 O 1
1 1 �
�0� SPAT OF
0 N.
�`
,,,,� ///i
BUILDING DESIGN PROPERTIES SYMBOL VALUE UNIT
BASIC WIND SPEED UK
mph Figure 26.5-1C,page 249a
ROOF PITCH degrees
MEAN ROOF HEIGHT ft
ROOF SETBACK ftADJUSTMENT FACTOR FOR BUILDING Figure 30.5-1,pg 347
HEIGHTAND EXPOSURE
TOPIGRAPHICAL FACTOR Figure 26.8-1,pg 252
EXPOSURE EFFECTIVE WIND AREA sf
ZONE ZONE ZONE3
-E UNIT REFERENCE:ASCE 7-10
VARIABLE DESCRIPTION SYMBOL VALUE VALUE VALUE
NET DESIGN WIND PRESSURE(UPLIFT) P_ 32.3 56.2 -83.1 psf Figure 30.5-1,pg 346
NET DESIGN WIND PRESSURE(DOWN) P„.: 20.3 20.3 20.3 psf Figure 30.5-1,pg 346
NET DESIGN WIND PRESSURE(UP) P„Er„i, -32.30 -56.20 -83.10 psf Calculation:P,, ,=A x Kz,x P°r,3o
NET DESIGN WIND PRESSURE(DOWN) P°.r d°w° 01 20.301 20.30 psf Calculation:P-d°,„,=Xx Kztx P°e3u
DESCRIPTION SYMBOL VALUE VALUE VALUE UNIT
DEAD LOAD D P3230
3 3 psf
SNOW LOAD S 0 0 psf
DESIGN WIND LOAD W -56.20 -83.10 psf
ASO DESIGN LOAD(UPLIFT) P,,, -22.70 -41.21 -62.05 psf Calculation:Pd�jv=D+SQRT(0.6)W(asd)
,i DOWNFORCE CASE 1 Pdr'° 3 3 3 psf Calculation:Pde 1p=S.OD+I.OS
DOWNFORCE CASE 2 Peraen 23.30 23.30 23.30 n:psf Calculatio Pd.o=1,0D+1.0W
DOWNFORCE CASE 3 Pdesrsn 18.23 18.23 18.23 psf Calculation:Pdesja°=1.OD+0.75S+0.75W
DESIGN FACTORS&CALCULATIONS FOR THE USE OF L-FOOT TO ROOF TRUSS
DESCRIPTION SYMBOL VALUE-VALUE VALUE UNIT
MODULE LENGTH C 5A2 ft
MODULEWIDTH B 3.33 ft
DESIGN LOAD PER MODULE T -410.04 -744.5 -1120.95 Ibs Calculation:T=Area"W
DISTRIBUTED LOAD(UPLIFT) w -61.51 -111.68 -168.14pif Calculation:w=T/B'2"`�:umezzraitcve<r°-
DISTRIBUTED LOAD(DOWNFORCE) w 38.83 38.83 38.83pif Calculation:w=PB/2
RAIL SPAN BETWEEN ANCHORS POINTS L 4 4 4 ft
POINT LOAD(UPUFr) R -2,46.02 -446.70 -672.57lbs calculation:R=PLB/2"'v90"1Sz"�hveftlW
POINT LOAD(DOWNFORCE) R 155.33 155.33 155.33 Ibs Calculation:R=PLB/2"'�:°me:zrain cerrow
L-FOOT CONNECTED BY LAG SCREW TO
ROOF TRUSS)RAFTER
Specific Gravity,Rafter Gr0,3125
0.55 0.55 Table 11.2A,NDS 2005,page 68(Southern Pine)
Min.Dia.of lag Screw,5/16 D 0,3125 0.3125 In /l '
Pullout Value of W 306.87 306.87 Ibs/in W=1800 G D#of Lag screws 1 1
Thread Length Td 2.8 2.8 In Table L2,NDS 2005
Design Pullout Value per Mount WL 859.235 859.235 Wr=W'#of Lags'Td
SAFTEY FACTOR SF 3.49 1.92 1.28 Calculation:SF=WvR(Uplift)
aep a:nela<mlerllmJyavrr•nrl<uedl '
u,i°:�fw.xsnW.lL.rJ...acr<maaa nc�.not:n:..
innlw.a onw.iinroa_ Hnrpp°,i+t'+,h{.a<n°cmaWpc.
u.,em4 lcl+airn rulrnw lar D^'gv<m I.le<•rM.71oe
1.s,nr]wa.rtin]M!Y]4rf 2
Itrue'2}•,r1eW Mdhir•]a wagdrocf! .
F W Roof Nip RoO(7'<I s 27•)
100 ,
Gate Rear l05,7•�" Gable Reel
C.
�! a. 136
.. 7
Intnn Zonet Ld,Z- C-7-, i7hh0 .
u�h.7tw! ZA
i�ra<nSQSn7Cf.M•Me+>r{aMMh•lro NR4+bov.O.ca•A p.l. M�� , J� I ��.