Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
20-1168
i r ' j City of Zephyrhills PERMIT NUMBER r r 'yu r 5335 Eighth Street Zephyrhills, FL 33542 FIRE-001168-2020 Phone: (813)780-0020 Fax: (813)780-0021 Issue Date: 01/05/2021 Permit Type: Fire Property Number NEEKS0171"LeU Address 15 26 21 0030 03100 0000 37737 C Avenue Owner Information Permit Information Contractor Inforration Name: SOUTHSIDE CHURCH OF CHRIST Permit Type:Fire Contractor:ADT COMMERICAL Class of Work:Fire Alarm Address: 37737 C Ave Building Valuation:$250.00 ZEPHYRHILLS,FL 33542 Electrical Valuation: Phone: (813)783-2305 Mechanical Valuation: Plumbing Valuation: cam\/n1 Total Valuation:$250.00 I �✓ Total Fees:$150.00 / Amount Paid:$150.00 Date Paid:1/5/2021 9:07:03AM Project Description INSTALLATION DEFECTIVE PANEL Application Fees System Acceptance Inspection $50.00 Fire Alarm System Plan Review $50.00 Fire Alarm Permit Fee(1-25) $50.00 REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each subsequent reinspection. Notice: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permit required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications add fee Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. CONTRACTOR SIGNATURE PE IT OFFICE PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER ADT- Commercial Powered by Experience. Driven by Excellence." Tampa Office—180 Scarlet Boulevard Oldsmar,Florida 34677 (813)925-1007 (813)925-0299-Fax EC13004155 NATIONAL FIRE ALARM CODE PAGE 1 Record Of Completion Name of Protected Property SOUTHSIDE CHURCH OF CHRIST Address 37737 C AVE ZEPHYRHILLS FL 33542 Rep.of Protected Prop.(name/phone): Authority Having Jurisdiction: Address/Phone Number. 1 Type(s)of System or Service X NFPA 72,Chapter 3-Local If Alarm is transmitted to location(s)off premise,list where received: NFPA 72,Chapter 3-Emergency Voice/Alarm Service Quantity of Voice/Alarm channels: Single: Multiple: Quantity of speakers: Quantity of speaker zones: Quantity of telephones or telephone jacks included in system: NFPA 72,Chapter 4-Auxiliary Indicate type of connection: Local Energy, shunt Parallel telephone Location and telephone number for receipt of signals: NFPA 72,Chapter 4-Remote Station Alarm: Supervisory: NFPA 72,Chapter 4-Proprietary If alarms are retransmitted to public fire service communications center or others,indicate location and telephone number of the organization receiving alarm: indicate how alarm is retransmitted: NFPA 72,Chapter 4-Central Station The Prime Contractor. Central Station Location: Means of transition of signals from the protected premise to the central station: Mcculloh Multiplex One-Way Radio X Digital Alarm Communicator Two-Way Radio Others Means of transmission of alarms to the public fire service communications center. Digital Dialer from Main Panel 2. System Location: Organization Name/Phone Representative Name/Phone Installer ADT Commercial KENNETH HAYNES JR Supplier ADT Commercial KENNETH HAYNES JR Service ADT Commercial DAWN FRANZ Location of Record(As-Built)Drawings: FACP Location of Owners Manuals: FACP Location of Test Reports: FACP a contract,Dated for test and inspection in accordance with NFPA standard(s)No.(s) dated is in effect National Fm Almon Code PAGE 2 - Record of System Installation ut after installation is complete and wiring checked for opens,shorts,ground faults,and improper branching,but) Pndr W conducting operational acceptance tests.) This System has been installed in accordance with the NFPA standards as listed below,was inspected by on includes the devices listed below and has been in service since X NFPA 72,Chapters 1 3 4 5 6 7 (circle all that apply) NFPA 70,National electrical Code,Article 760 Manufacturer's instructions other(specify): Plans and specifications Signed: Date: Organization: ADT Commercial 3. Certification of System Operation All operational features and functions of this system were tested by on and found to be operating properly in accordance with the requirements of: X NFPA 72,Chapters 1 3 4 5 6 7 (circle all that apply) NFPA 70,National Electrical Code,Article 760 Manufacturer's Instructions other(specify): Plans and specifications Signed: Date: Organization: ADT Commercial 4. Alarm Initiating Devices and Circuits (use blanks to indicate quantity of devices) a) X Manual Stations noncoded,Activating transmitters Coded b) Combination Manual Fire Alarm and Guard's Tour Coded Stations AUTOMATIC Coverage: Complete: Partial: a) X Smoke Detectors Ion Photo b) Duct Detectors Ion Photo c) Heat Detectors FT RR FT/RR RC d) Sprinkler Watertiow Switches Noncoded,activating transmitters coded e) Other(list) ,a- Supervisory Signal Initiating Devices and Circuits (use blanks to indicate quantity of devices.) GUARD'S TOUR a) Coded Stations b) Noncoded Stations Activating Transmitters c) Compulsory Guam Tour System Comprised of transmitter Stations and Intermediate Stations Note:Combination devices recorded under 4(b)and 5(a). SPRINKLER SYSTEM a) Non-Coded Valve Supervisory Signaling Attachments Valve Supervisory Switches Activating Transmitters b) Building Temperature Points c) Site Water Temperature Points d) Site Water Supply Level Points Electric Fire Pump: e) Fire Pump Power f) Fire Pump Running g) Phase Reversal Engine-Driven Fire Pump: h) Selector in Auto Position i) Engine or Control Panel Trouble j) Fire Pump Running Engine-Driven Generator. k) Selector in Auto Position 1) Control Panel Trouble m) Transfer Switches n) Engine Running NATIONAL FIRE ALARM CODE PAGE 3 Other Supervisory Function(s)(specify): :Harm Notification Appliances and Circuits Quantity of indicating appliance circuits connected to the system: Types and quantities of alarm indicating appliances installed: a) Bells Inch Speakers b) X Homs c) Chimes d) Other e) X Visual Signals Type: with audible with out audible f) 1 Local Annunciator 7. Signaling Line Circuits: Quantity and Style(See NFPA 72,Table 3-6.1)of signaling line circuits connected to system: Quantity: 1 Style: Y 8. System Power Supplies: a) Primary(Main): Nominal Voltage 120 VAC Current Rating 3 AMPS Overcurrent Protection: Type CIRCUIT BREAKER Current Rating 20 AMPS Location: b) Secondary(Standby): 2 Storage Battery: Amp-Hour Rating 7 AMP HOUR Calculated capacity to drive system,in hours. 24 60 Engine-driven generator dedicated to fire alarm system: Location of fuel storage: c) Emergency of Standby System used as backup to Primary Power Supply,instead of using a Secondary Power Supply: Emergency System described in NFPA 70,Article 700 Legally Required Standby System described in NFPA 70,Article 701 Optional Standby System described in NFPA 70,Article 702,which also meets the performance requirements of Article 700 or 701 ►stem Software a) Operating System Software Revision Level(s): b)Application Software Revision Level(s): c) Revision Completed by: KENNETH HAYNES JR ADT COMMERCIAL (name) (firth) 10. Comments: HEADIN CHANGE OUT FIRE LITE (signed)for Central Station or Alarm Service Company (title) (date) Frequency of routine tests and inspections,if other than in accordance with the referenced NFPA standard(s): System deviations from the referenced NFPA standard(s)are: (signed)for Central Station or Alarm Service Company (title) (date) ktpon comptj of the syste atisfactory test(s)witnessed(if required b the utho' having jurisdiction): signed)representative of the authority having jurisdiction (title) (date) (signed)owner representative or authority having jurisdiction (title) (date) 813-780-0020 City of Zephyrhills Fire' Fax-813-780-0021 Permit Application Date Received (�� Phone Contact for Permit 7 Owner's Name J~ (:� 'T [ Owner's Phone Number OS � Owner's Address o1 Fee Simple Titleholder Name Titleholder Phone Number Fee Simple Titleholder Address Job Address Lot# ---�� Sub Division Parcel# Bio-Hazard Waste Storage-ANNUAL F-1 Fumigation Tent QComm Exhaust Kitchen HooMuct F 7-1 Hazardous Material(Tier 11 or RQ Facility)AN U rI Controlled Burn E] Hood Installation QEmergency Generator<30 kw F7 LPMaturat Gas-Instaliatior Emergency Generator>30 kw LP/Natural Gas ANNUAL Sale 3 � r7 Fire Protection Maintenance-ANNUAL Q Places of Assembly-ANNUAL / �l[ tr emi rA—nn Other Sprinkler ❑ ❑ ❑ r Recreational Bum ' �+ V p Fire Alarm � ❑ ❑ ❑ El Sparklers � 9 Hood Cleaning ❑ ❑ I-] System Installations Hood Suppression ED ❑ ❑ ❑ Standpipes(Sprinkler Sys) Fire Alarm Installation Torch RoofingfTar Kettle QFire Pumps Waste Tire Storage ANNUAL 8 Flammable Application-ANNUAL �� Valuation of Project Fuel Tanks Other: Contractor Company (� Signature Registered Y/N Fee Current Y/N Address License# S ELECTRICIAN Company Signature Registered Y/N Fee Current Y!N . Address License# PLUMBER Company Signature Registered Y/N Fee Current Y/N., Address License# MECHANICAL Company Signature Registered Y/N Fee Current Y/N Address License# OTHER Company Signature Registered Y/N Fee Current Y!N Address License# Directions: Fill out application completely. Owner&Contractor sign back of application,notarized(Or,copy of signed contract with owner) If over$2500,a Notice of Commencement is required(Mechanical work over$5000) Supply two(2)sets of drawings with applicable documentation Allow,10-14 days for review after submittal date. Parcel#-obtained from Property Tax Notice(htip://appraiser.pascogov.com) it DAWN FRANZ MY COMMISSION#GG 186687 EXPIRES:February 28,2022 11 Bonded 7bru Notary Public Underwriters . u i� 11� �I i� �I l III III I II I I� I I� . II DF-52417:D•B-90 ANN-80 � Flre•LITe®ALarms SO-Character.Serial LCD Annunciator by Honeywell Annunciators General The ANN-80 annunciator is a compact, backlit, 80-character LCD fire annunciator that mimics the Fire Alarm Control Panel (FACP) display. It provides system status indicators for AC Power, Alarm, Trouble, Supervisory, and Alarm Silenced conditions. The ANN-80 and the FACP communicate over a two-wire serial interface employ At A - ing the ANN-Bus communication format. Connected devices are IQt powered, via two additional wires, by either the host FACP or a remote UL-listed, filtered power supply. The ANN-80 is red; for white, order ANN-80-W. The ANN-80 displays English-language text of system point informa- tion including device type,zone,independent point alarm,trouble or by,Honeywell supervisory status,as well as any custom alpha labels programmed into the control panel. It includes control switches for remote control of critical system functions. (A keyswitch prevents unauthorized operation of the control switches.) Up to eight ANN-80s may be connected to the ANN-Bus of each FACP.No programming is required,which saves time during system commissioning. Features Supervisory . • Alarm Silenced • Listed to UL Standard 864,9th Edition • Backlit 80-character LCD display(20 characters x 4 lines) Specifications • Mimics all display information from the host panel Operating voltage range: 18 VDC to 28 VDC • Control switches for System Acknowledge, Signal Silence, Drill, Current consumption @ 24 VDC nominal (filtered and non- and Reset resettable):40 mA maximum • Control switches can be independently enabled or disabled at the Ambient temperature:32°F to 120°F(0°C to 49°C) FACP Relative humidity: 93% ± 2% RH (non-condensing) at 32°C ± • Keyswitch enables/disables control switches and mechanically 2°C(90°F t 3°F) locks annunciator enclosure 5.375"(13.65 cm.)high x 6.875"(17.46 cm.)wide x 1.375'(3.49 • Keyswitch can.be enabled or disabled at the FACP cm.)deep • Enclosure supervised for tamper For use indoors in a dry location • System status LEDs for AC Power,Alarm, Trouble, Supervisory, All connections are power-limited and supervised and Alarm Silence • Local sounder can be enabled or disabled at the FACP The ANN-Bus • ANN-80 connects to the ANN-Bus terminal on the FACP and requires minimal panel programming POWERING THE DEVICES ON THE ANN-BUS FROM AUX/L- • Displays device type identifiers, individual point alarm, trouble, IARY POWER SUPPLY supervisory,zone,and custom alpha labels The ANN-Bus can be powered by an auxiliary power supply when • Time-and date display field the maximum number of ANN-Bus devices exceeds the ANN-Bus • Surface mount directly to wall or to single, double, or 4" square power requirements.See the FACP manual for more information. electrical box ANN-BUS DEVICE ADDRESSING • Semi-flush mount to single,-double, or 4" square electrical box. Each ANN-Bus device requires a unique address (ID Number) in Use ANN-SB80KIT for angled view mounting order to communicate with the FACP.A maximum of 8 devices can • Can be remotely located up to 6,000 feet (1,800 m) from the be connected to the FACP ANN-Bus communication circuit.See the panel FACP manual for more information. • Backlight turns off during AC loss to conserve battery power but WIRE REQUIREMENTS: COMMUNICATIONS CIRCUIT will turn back on if an alarm condition occurs • May be powered by 24 VDC-from the host FACP or by remote 'The ANN-80 connects to the FACP ANN-Bus communications cir- power supply(requires 24 VDC) cuit.To determine the type of wire and the maximum wiring distance • Up to eight ANN-80s can be connected on the ANN-Bus that can be used with FACP ANN-Bus.accessory modules, it is nec- essary to calculate the total worst case current draw for all modules on a single 4-conductor bus. The total worst case current draw is Controls and Indicators on by adding the individual worst case currents for each • AC Power module. • Alarm NOTE:For total"worst case current draw on a single ANN-Bus refer to • Trouble appropriate FACP manual. DF-524170•3/15/2018—Page 1 of 2 WIRE REQUIREMENTS:POWER CIRCUIT Agency Listings and Approvals • 14.to 18 AWG(0.75-2.08 mm2)wire for 24 VDC power circuit is The listings and approvals below apply to the ANN-80. In some acceptable. Power wire distance limitation is set by 1.2 volt maxi- cases,certain modules may not be listed by certain approval agen- mum line drop form source to end of circuit. cies, or listing may be in process. Consult factory for latest listing . • All connections are power-limited and supervised. status. A maximum of eight ANN-80 modules may be connected to this UL:S2424 circuit. • FM approved Ordering-Options CSFM:712070075:0211 ANN-80:Red 80 character LCD Annunciator. MEA:442-06-E ANN-80-W:White,80 character LCD Annunciator. ANN-SB80KIT-R:Red surface mount backbox with angled wedge. ANN-SB80KIT-W: White surface mount backbox with .angled wedge. Fire-Lite®Alarms is a registered trademark of Honeywell International Ind. ©2018.by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate.. ISO: SO 9001 We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. 6TCI111IMING a MMUFACTIINNG QUALITY SYSTEMS For more information,contact Fire-Lite Alarms.Phone:(800)627-3473,FAX:(877)699-4105. Country of Origin:USA WWW.firelite.coni Page 2 of 2—DF-52417:1)•M 5/2018 DF-524160•A3-20 MS-5UD(E)/MS-10UD(E) Series 8 FII'e•LITUALarl'Y1S Five Zone Fire Alarm Control .Panel Ten Zone Fire Alarm Control Panel by Honeywell . General The MS-011)-3(E) is a five-zone FACP (Fire Alarm.Control Panel)and the MS=10UD-7(E)is a ten-zone FACP.These con- trol panels provide reliable fire signaling protection for small to medium-sized commercial, industrial, and institutional build- ings. Both panels include built-in communicators for Central Station Service and remote upload/download. Each of these FACPs is compatible with System Sensor's microprocessor-based-i3 series detectors.These conventional smoke detectors can transmit a maintenance trouble signal to the FACP indicating the need for cleaning and a supervisory "freeze"signal when the ambient temperature falls below the detector rating. Additionally, both the MS-5UD-3 and MS 1OUD-7 are compatible, with conventional input devices such as two-and four-wire smoke detectors,pull stations,waterflow devices, tamper switches,. and other normally-open contact devices. Refer to the Fire-Lite Device Compatibility Document for a complete listing of compatible devices. N Outputs include four NACs (Notification Appliance Circuits), " three programmable Form-C relays (factory programmed for Alarm,Trouble;and Supervisory)and 24 VDC special applica- tion resettable and nonresettable power outputs. The FACPs supervise.all wiring, AC'voltage, battery level and telephone _Strobe Synchronization for System Sensor, Wheelock, line integrity. Gentex,Faraday,or Amseco devices. Activation of a compatible smoke detector or any normally- —Selective Silence(horn-strobe mute). open fire alarm initiating device will activate audible and visual signaling devices, illuminate an indicating LED, sound the —Temporal or Steady Signal. piezo sounder at the FACP, activate the communicator and —Silenceable or Nonsilenceable. FACP alarm relay, and operate an optional module used to Optional CAC-5X Style Z (Class A) Converter Module for notify a remote station or initiate an auxiliary control function. NACs and IDCs(2 required for MS-10UD-7). New options_include a UL listed printer, PRN-6F.and FireLite's Form-C Relays for Alarm, Trouble and Supervisory- Con- IPDACT Internet Monitoring module. The FireWatch Series' tact Ratings 2.0 ACC 30 VDC or 0.5 A @ 30 VAC(resistive). internet monitoring modules IPDACT-2 and IPDACT-2UD per- . 3.0 A total system current for MS-5UD-3. mit monitoring of alarm signals over the Internet saving the . 7.0 A total system current for MS-10UD-7. monthly cost of two telephone lines.Although not required,the secondary telephone line may be retained providing backup. Optional Dress Panel DP-51050 communication over the public switched telephone line. • Optional Trim Ring TR-CE for semi-flush:mounting. NOTE: The MS-5UD-3E and MS-10UD-7E offers the same fea- • 24 volt operation. tures as the MS-5UD-3 and MS-10UD-7 but allow connection to . Low AC voltage sense. 240 VAC. Unless otherwise specified, the information in this data . Alarm Verification. sheet applies to both the 120 VAC and the 240 VAC versions of these panels. • PAS(Positive Alarm Sequence). -NOTE:For ULC-listed models,see DF-60440. • Automatic battery trickle charger. • Up to eight-ANN-BUS annunciators: Features —Optional 8 zone Relay Module ANN-RLY. • Listed to UL Standard 864,9th edition. —Optional LED_Annunciator.Module ANN-LED, • Built-in DACT(Digital Alarm Communicator/Transmitter). —Optional Remote Annunciator ANN-80: • Style B(Class B) IDC(Initiating Device Circuit) —Optional Remote Printer Gateway ANN-S/PG. -MS-5UD-3-five IDCs. -Optional LED Annunciator Driver ANN-1/0. —MS-10UD-7-ten IDCs. Optional 4XTMF module (conventional reverse polarity/city • Style Y(Class B)NAC(Notification Appliance Circuit)-spe- box transmitter). cial application power PROGRAMMING AND SOFTWARE. —MS-5UD-3-four NACs. Can be programmed at the panel with no special software —MS-10UD-7-four NACs. or additional equipment. • Notification Appliances may be programmed as Programmable Make/Break Ratio. —Silence Inhibit. Upload/Download(local or remote)of program and:data via —Auto-Silence. integral DACT. DF-524160•07/26%2010—Page 1 of 4 USER INTERFACE. • SYSTEM RESET(lamp test) Built-in DACT(Digital Alarm Communicator/Transmitter). • DRILL • Integral 80-character LCD display with backlighting and . keypad. Terminal Blocks • Real-time clock/calendar with automatic daylight savings AC Power—TB1: adjustments. • MS-5UD-3 (FLPS-3 Power Supply): 120 VAC, 50/60 HZ, • ANN-BUS for connection to remote annunciators. 1.00 A. • Audible or silent walk test capabilities. • MS-5UD-3E (FLPS-3 Power Supply): 240 VAC, 50 HZ, • Piezo sounder for alarm,trouble,and supervisory. 0.54 A. . • MS-10UD-7 (FLPS-7 Power Supply): 120 VAC, 50/60 HZ, Controls and Indicators 3.80 A. LED INDICATORS MS-10UD-7E(FLPS-7 Power Supply): 240 VAC,50/60 HZ, 2.20 A. FIRE ALARM(red) Wire size:minimum 14 AWG(2.00 mm2)with 600 V insulation. • SUPERVISORY(yellow) Supervised,nonpower-limited. • TROUBLE(yellow) Battery(sealed lead acid only)—J12: • AC POWER(green) • Maximum Charging Circuit-Normal Flat Charge:27.6 VDC • ALARM SILENCED(yellow) @ 1.4 A.Supervised,nonpower-limited. CONTROL BUTTONS • Maximum Charger Capacity: 18 AH battery for MS-5UD- • ACKNOWLEDGE 3(E),and 26 AH battery for MS-10UD-7(E).[Two 18 Ah bat- teries can be housed in the FACP cabinet. Larger batteries • ALARM SILENCE require separate battery box such as the BB-26 or BB-55.1 Depth=5.207"(13.23 cm) Top i ( Door=16.821"(42.73 cm) � Depth= Backbox=16.65"(42.29 cm) I b•257"_ �I (13.353 cm) Door=19.26"(48.92 cm) Backbox=19.0"(48.26 cm) ' 3 Left Side Right Side ............................................•... ..............................................0. Bottom Cabinet Measurements Page 2 of 4—DF-524160•07/2 612 0 1 0 • Minimum Battery Size:7 AH. MS-10UD-7E:Same as above with 240 VAC FLPS-7. Initiating Device Circuits—TB4 (and TB 6 on MS-10UD-7 IPDACT, IPDACT 2/2UD Internet Monitoring Module: only): Mounts in bottom of enclosure with optional mounting kit(PN • Alarm Zones 1 -5 on TB 4(MS-5UD-3 and MS-10UD-7). IPBRKT). Connects to primary and secondary DACT tele- • Alarm Zones 6-10 on TB6(MS-10UD-7 only). phone output ports for internet communications over customer provided ethernet internet connection. Requires compatible • Supervised and power-limited circuitry. Teldat Visoralarm Central Station Receiver.Can-use DHCP•or • Operation:All zones Style B(Class B). static IP. (See data sheet DF-60407 for more information.) • Normal Operating Voltage: Nominal 20 VDC. IPBRKT:Mounting kit for IPDACT in common enclosure. • Alarm Current: 15 mA minimum. IPSPLT: Y Adaptor option to allow connection of both panel' • Short Circuit Current:40 mA max. dialer outputs to one cable input to IPDACT(sold separately). • Maximum Loop Resistance: 100 ohms. OPTIONAL MODULES • End-of-Line Resistor: 4.7K ohm, 1/2 watt (P/N 71252 UL- CAC-5X:Optional(Class A)Converter Module.Converts Style listed). - B(Class B) Initiating Device Circuits to Style D(Class A); and • Standby Current:2 mA. Style Y (Class B) Notification Appliance Circuits to Style Z Refer to the Fire-Lite Device Compatibility Document for listed (Class A). Connects to J2 on the MS-5UD-3 and MS-10UD- compatible devices. 7(E)main circuit board and to J7 on the MS-10UD-7(E). Notification Appliance Circuits —T135.(and TB 7 on MS- NOTE. Two Class A Converter Modules_ are required for the ten- 10UD-7 only): zone panel. • Four NACs 4XTMF:Transmitter module. Provides a supervised output for • Operation:Style Y(Class B) local energy municipal box transmitter and alarm and trouble reverse polarity. Includes a disable switch and disable trouble • Special Application power LED.A module jumper option allows the reverse polarity circuit • Supervised and power-limited circuitry to open with a system trouble condition if no alarm conditions • Normal Operating Voltage:Nominal 24 VDC exists.Mounts to the main circuit board connectors J4 and J5. Maximum Signaling Current: 3.0 A for MS-5UD-3, 2.5 A COMPATIBLE ANNUNCIATORS maximum per NAC; 7.0 A for MS-10UD-7(E), 3.0 A maxi- mum per NAC. ANN-80: Remote LCD Annunciator. Mimics the information • m, watt End-of-Line Resistor:4.7K oh 1/2 (Part#71252) displayed on the FACP's LCD. Red. (For white, order: ANN- 80-W.) • Max.Wiring Voltage Drop:2 VDC ANN-LED: LED Annunciator with three LEDs for each zone: Refer to the Fire-Lite Device Compatibility Document for com- Alarm, Trouble, and Supervisory. Mounts in the DP-51050(B) patible listed devices. dress panel.Red.(For white,order ANN-LED-W.) Form C Relays—T138: ANN-BLED: LED Annunciator with three alarm (red) indica- • Relay i(factory default programmed as Alarm Relay)_ tors for up to 30 input zones or addressable points.(Red. For • Relay 2 (factory default programmed as fail-safe Trouble white,order ANN-LED-W.) (See DF-60241). Relay) ANN-RLY: Relay module. Mounts inside the cabinet. Provides • Relay 3(factory default programmed as Supervisory Relay) ten Form C relays. Special Application Resettable Power—TB9: ANN-S/PG:Serial/parallel printer gateway.Provides a connec- • Jumper selectable by JP31 for resettable or nonresettable tion for a serial or parallel printer. power. ANN-1/0: Driver module. Provides connections to a user-sup- Operating voltage:24 VDC nominal. plied graphic annunciator. • Maximum available current: 500 mA-appropriate for pow- ACCESSORIES ering four-wire smoke detectors. DP-51050: Optional dress panel. Restricts access to the sys- • Power-limited circuit. tern wiring while allowing access to the membrane switch Refer to the Fire-Lite Device Compatibility Document for listed panel. compatible devices. BB-26: Battery backbox, holds up to two 25 AH batteries and Remote Sync Output-TB2: Remote power supply synchro- CHG-75. nization output,only required for the MS-5UD-3.24 VDC nom- BB-55: Battery backbox,holds up to two 25 AH batteries. inal special application power. Maximum current is 40 mA. End-of-Line Resistor: 4.7K ohm. Supervised and power-lim- TR-CE:Optional trim-ring for semi-flush mounted cabinets. ited circuit. PRN-6F: UL listed printer. Product Line Information MS-5UD-3: Five-zone, 24-volt Fire Alarm Control Panel (includes backbox, FLPS-3 power supply, technical manual, and a frame & post operating instruction sheet). 120 VAC operation. MS-51.113-3E: Same as MS-5UD-3 except for 240 VAC opera- tion. MS-10UD-7: Ten-zone, 24-volt Fire Alarm Control. Panel (includes backbox, FLPS-7 power supply, technical manual, and a frame&post operating instruction sheet).. DF-524160•07/26/2010—Page 3 of 4 SYSTEM SPECIFICATIONS System Capacity. Temperature and Humidity Ranges • Annunciators......................................................................8 This system meets NFPA requirements for operation at 0- 49°C/32 — 120°F and at a relative humidity.93% t 2% RH Electrical Specifications (noncondensing) at 32°C t 2°C (90°F t 30F). However, the useful life of the system's,standby batteries and the-electronic • MS-5UD-3 (FLPS-3 Power Supply): 120 VAC, 60 HZ, components may be adversely affected by extreme tempera- 1.0 A ture ranges and humidity.- Therefore, it is recommended that • MS-10UD-7 (FLPS-7 Power. Supply): 120 VAC, 60 HZ, this system and its peripherals be installed in an environment 3.90 A with a normal room temperature of 15—27°Ci60—80°F. • MS-5UD-3E (FLPS-3 Power Supply): 240 VAC, 50 HZ, 0.54 A. Agency Listings and Approvals MS-10UD-7E (FLPS-7 Power Supply): 240 VAC, 50 HZ, The listings and approvals below apply to the basic MS-5UD-3 2.20 A. and MS-10UD-7 control panels. In some cases, certain mod- • Wire size: minimum 14 AWG (2.0 mm2).with 600 V insula- ules or applications may not be listed 'by certain approval tion,supervised_,nonpower-limited agencies, or listing may in process. Consult factory for lat- est listing status. Cabinet Specifications • UL Listed:File S624 Door: 19.26" (48.92 cm.) high x 16.82" (42.73 cm.) wide x • FM Approved 0.72" (1.82 cm.) deep. Backbox: 19.00" (48.26 cm.)-high x • CSFM:7165-0075:0214 16.65" (42.29 cm.) wide x 5.25" (13.34 cm.) deep.Trim Ring . MEA: MEA:333-07-E (TR-CE):22.00"(55.88 cm.)high x 19.65"(49.91 cm.)wide. NOTE.For ULC-listed,models,see DF-60440. . Shipping Specifications NFPA Standards Dimensions: The MS-5UD-3(E) and MS-10UD-7(E) complies with the fol- lowing NFPA 72 Fire Alarm Systems requirements: —22.5 (57.15 cm.)wide —LOCAL (Automatic, Manual, Waterflow and Sprinkler 8.5"(21.59 cm.)deep. Supervisory). Weight:27 lb(12.20 kg) —AUXILIARY(Automatic, Manual and Waterflow) (requires 4XTMF). —REMOTE STATION (Automatic, Manual and Waterflovu) (Where a DACT is not accepted, the alarm, trouble and . supervisory relays may:be connected to UL 864 listed transmitters. For reverse polarity signaling of alarm and trouble,4XTMF is required.) —PROPRIETARY(Automatic,Manual and Waterflow). —CENTRAL STATION (Automatic, Manual and Waterflow, and Sprinkler Supervised). -PT, PSDN (Other Technologies, Packet-switched Data Network) FireLite® Alarms and System Sensor® are registered trademarks of Honeywell International Ind." ©2010 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. 1 S 0 9001 We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements:- ENCINBIN®8 A7ANUFACTIIIIING All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S.A. For more information,contact Fire-Lite Alarms.Phone:(800)627-3473,FAX:(877)699-4105. www.firelite.com Page 4 of 4—DF-524160.67/26/2010 Scope of Work • Southside Church of Christ 37737 C AVE Zephyremills,FL Intrusion Alarm t C FT r Fire Alarrn Control Panel .m Fire Alarm Keypad ))) Cellular Backup REVIEWDATE oZ •// •�• Z� �Q Door Contact CITY OF ZEPHYRMILLS p Overhead Door FIRE AND LIFE SAFETY EXAMINER " Contact ILL Motion Detector(Long 'Q Range) Motion Detector z ide Angle) ��p BAS01 Motion Detector C1 (Ceiling Mount Glassbreak Detector - E A_ Photo-Electric Beam Transmitter PE «� Photo-Electric Beam 4 Receiver PE " Panic Button ALL WORK SHALL COMPLY WITH 4 NFFA CODES AND.STANDARDS 4 ))) Siren p" Access Control 9:. 43 MAccess Control . Reader Q"..�:.4 4 ..6 4 Access Control Reader Access control ADT will replace the existing MS 5210 10 zone fire panel with a new MS 10 UD 10 Zone,Fire Panel with 7 amps of power for horn and horn Keypad Access Control strobes. Keypad Access Control Panel ADT will pull a permit and move all the existing equipment from the existing panel to the view panel a test. " Locking Hardware .1 PowerSupply ADT will replace the annunciator at the front,door with,a new one. Video Surveillance Dome camera We will tie the two phone lines to the panel but we can offer a proposal for cellular communicator if the Church would like to eliminate those two phone lines. Camera and Housing Approximate Field of View Network Switch Camera Power Supply Digital Video Recorder spawn Network Video :Recorder Network Attached Storage Drawing and scope ofwork details are proprietary property of Protection i and may not be copied or distributed without consent ofsa/es rep. Monitor Request for copies should be made to sales rep and fees may apply. ZEPHYRHILLS FIRE DEPARTMENT 38410 6th Ave Zephyrhills, FL 33542 FIRE''SERVICE USER FEES increase 1/1/2018 Occupancy.No.: Plan No_: Contractor: Business Name: a U l*w s .o v' C 44•c/— Billing Address: Business Address: 3 7 -7 31 C-i4-1 Business,Phone.No.: Billing-Phone No.: Business Fax No.: Billing Fax.No.: Contact:' Contact: PLAN REVIEW FEES INSPECTION FEES PERMIT FEE Annual- Education,healthcare,De tention&Correctional Public Assembly,Business, schools, Storage,Mercantile and -Churches Site Plan N/C Industrial. no charge Sprinkler $50 `Multi-Family/Commerclal :03 sf up to 800 sq ft $ 24.00• Standpipes $50 (Minimum Charge$24.00 801-1,500 sq ft $ 34.52 Fire Pump $50 0'Plan Revisions DBL. '1,501-2,500 sq ft $ 60.02 Hoods $50 2,501-3,500 sq ft $ 90.02 Fire Alarm $50 SPRINKLER SYSTEMS 3,501-5,000 sq ft $ 127.52 LP Gas $50 ff0-25-Heads $50 5,501-7,500 sq ft $ .187.52 .Natural Gas $50 26,p!ue,Heads $100 7,501-10,-000 sq ft $ 262.52 Fuel,Tanks- per tank $50 .STANDPIPE.SYSTEM :"10,001-15,000 sq ft $ 375.02 Sparklers $100 .0'Per Riser $50 . 15,001-20,000 sq ft $ 525.02 Fire Works $500 FIRE'PUMP 20,001-30,000 sq ft $ 750.02 Camp,Fire(recreation' $25 Per Pump $100 30,00140,000 sq ft $ 1,050.02 Controlled.Bum(15da: $100 FIRE:ALARM SYSTEM 40,001=60,000 sq ft $ 1,500.02 Hood/Duct $50 0-25-Devices $50 60,001=80,000 sq ft $ 2,100.02 Place of Assembly $50 Annual 80,001-($2,100.02)per 26.plus:Devices $100 ea add.1,000sq ft $ 0.06 Fire Protection $25 SUPPRESSION"SYSTEMS. . '(Business'closedvntil Flammable Application $50 Annual Wet $50 ;violations corrected) Waste Tire Storage $50 Annual Dry $50 ',,SPRINKLER SYSTEMS Generator<KW $100 CO2 $50. '.,Hydro Undergrounds $45 Generator>30 KW $100 Other $50BAcceptance HydrostaticTest $65 per system Bto-Hazard Waste $100 Annual KITCHEN EXHAUST Test $45 per system Fumigation Tenting $50 Hood/D.ucis $50 Hydrant'Flow $75 Torch.PottApplied $50 .OTHER Haz.Materials $50 Annual 8 LP.Installation.per tank $50 FIRE ALARM SYSTEM Fuel:Tarikinlitalldtion .$50.; ;Symem�Acceptance $50 (Pee'TMk)' $50 '.Recall Acceptance $50 Natural:Gas Installation $50 OTHER (Per-Systern) Flee Wall/Smoke Wall $15 per wall Spray.Booth $50 ALP Gas $25 per tank {Natural Gas $25 per system r Tent 10'x10'or greater $15 per tent 1�tre Pump $45 Fire Suppression $30 -System Acceptance 'Exhaust Hood/Duct $30 Re-Inspection DBL :(other than annual) Inspection scheduled DBL and cancelled less than 24 hours Construction Insp. N/C Emergency Vehicle Acce $50 PLANS-TOTAL INSPECTION TOTAL PERMIT TOTAL® GRAND TOTAL /CIO 94-1 Comments: Date: P;� -A3 ,.Inspector: ---�-- see.back nlh 1F r ^.��4;;�s�r.,�':��;r.:r�p�'��++gs�r��3r�..:cvxc.�-��aa��ic^ssu�fin+;nx�;.rce,.,-�,..�.c.:a-�••o�scrn.xmscws.ew*...,..�n..m�..•-...,��,,.......,,......a...d..........-.,...�..._........_._. Powered by Experience'.COCY2'CICAIDT® Driven by Excellence:" 12/3/2020. Zephyrhills Building Department Contractor Authorized Agent Affidavit I Edward Pleffner grant authorization.to the following:persons Nicole Smith and/or Mark Trio to act as my agent with._the City:of Zephyrhills while conducting activities.related to obtaining permits acid/or inspections: Sincerely, Edward Pleffner EC13004155 State of County of= -viR� u�� Th regoing instrument-was,sworn to(or affirm ,subscri d, nd acknowle i b e m ris-of vO'physical presense_onine notarization on this day of 2020,.b is b. personally known tome or has produced as identification. DAWN FRANZ FAIR*, MnOMMISSION_O GG 186687. a� EXPIRES:February 28,2022_ q w,°Q'� Bonded Thru Notary Public Underwriters Signature of Notary adt.com/commercial :1501 YAMATO ROAD, BOCA.RATON, FL 33431 ... 02020 ADT Commercial LLC.All rights reserved.