HomeMy WebLinkAbout20-1177 4
� a
f
City of Zephyrhilis PERMIT NUMBER
5335 Eighth Street
Zephyrhills, FL 33542 ELCMISC-001177-2020
f p - Phone: (813)780-0020
Fax: (813)780-0021 Issue Date: 01/06/2021
Permit Type: Electric Service Replacement/Misc
Property Number Street Address
24 26 21 0110 00000 3220 39672 Dawson Chase Drive
Owner Information Permit Information Contractor Information
Name: NICOLAS CASTANEDA Permit Type:Electric Service Replacement/M Contractor: US SO R
Class of Work:Add/Alter Residential
Address: 39672 Dawson Chase Dr Building Valuation:$23,112.00
ZEPHYRHILLS,FL 33540 Electrical Valuation:$3,000.00
Phone: (954)822-0546 Mechanical Valuation:
Plumbing Valuation:
Total Valuation:$26,112.00
Total Fees:$315.84
Amount Paid:$315.84
Date Paid:1/6/2021 11:47:07AM
Project Description
INSTALLATION ROOF MOUNT SOLAR
Application Fees
Electrical Plan Review Fee $27.50 Electrical Permit Fee $55.00
Building Permit Fee $155.56 Plan Review Fee $77.78
REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c)the
local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or
first reinspection,whichever is greater,for each subsequent reinspection.
Notice: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that
may be found in the public records of this county, and there may be additional permit required from other governmental
entities such as water management, state agencies or federal agencies.
"Warning to owner: Your failure to record a notice of commencement may result in your paying twice for
improvements to your property.If you intend to obtain financing,consult with your lender or an attorney
before recording your notice of commencement."
Complete Plans,Specifications add fee Must Accompany Application.All work shall be performed in
accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O.
NO OCCUPANCY BEFORE C.O.
CO CTOR SIGNATURE PE IT OFFICE
PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION
CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED
PROTECT CARD FROM WEATHER
r esunaing uepartmeni
Date Received 813 808 - 0218 Phone Contact for Permitting ,
aaaaaaaa
Owner's Name Nicolas Posada Owner Phone Number (954) 822-0546
Owner's Address 39672 Dawson Chase Drive,Zephyrhills,Florida 33540 Owner Phone Number
Fee Simple Titleholder Name Owner Phone Number
Fee Simple Titleholder Address
JOB ADDRESS F 39672 Dawson Chase Drive, Zephyrhills, Florida 33 440 LOT# 322
SUBDIVISION HIDDEN RIVER PHASE TW PARCEL ID# 24-26-21-0110-00000-3220
(OBTAINED FROM PROPERTY TAX NOTICE)
WORK PROPOSED B NEW CONSTR E ADD/ALT = SIGN = = DEMOLISH
INSTALL REPAIR
PROPOSED USE = SFR 0 COMM = OTHER
TYPE OF CONSTRUCTION = BLOCK Q FRAME 0 STEEL =
DESCRIPTION OF WORK ROOF MOUNTED SOLAR PANEL INSTALL
BUILDING SIZE SQ FOOTAGE HEIGHT
BUILDING $ 23,112 VALUATION OF TOTAL CONSTRUCTION
ELECTRICAL $ 35000 AMP SERVICE = PROGRESS ENERGY 0 W.R.E.C.
=PLUMBING $
=MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION
=GAS = ROOFING 0 SPECIALTY = OTHER
FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES NO
BUILDER COMPANY US SOLAR
SIGNATURE REGISTERED Y/N FEE CURREN Y/N
Address 2732 Broadway Center BLVD.Brandon, FL 33510 License# CVLr57002
ELECTRICIAN v /�I: COMPANY GENESIS ELECTRIC SERVICES LLC.
SIGNATURE j v���`� REGISTERED Y/N FEE CURREN Y/N
Address 2825 Murray Pass, Odessa FL 33556 License# 013007122
PLUMBER COMPANY
SIGNATURE REGISTERED Y/N FEE CURREN Y/N
Address License#'
MECHANICAL COMPANY
SIGNATURE REGISTERED Y/N FEE CURREN Y/N
Address License#
OTHER COMPANY
SIGNATURE REGISTERED Y/N FEE CURREN
Address License#
RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction,
Minimum ten(10)working days after submittal date.Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed,
Sanitary Facilities&1 dumpster;Site Work Permit for subdivisions/large projects
COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms. R-O-W Permit for new construction.
Minimum ten(10):vorkipg days_after-•submittal,date:Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed,,
Sanitary Facilities:&1%d.limpsfer,:Site Work,-Permit for;,all:new;`projects.All commercial requirements must meet compliance
SIGN PERMIT Attach(2)sets df,Engihb&red'P-lans:' `:3`' '",
****PROPERTYSLIRVEY,.requiredforairNEWc-'. fl ti,rr.;
Directions: '
Fill out application completely. �{
Owner&Contractor sign back of application,notarized
If over$2500,a Notice of Commencement is required.(A/C upgrades over$7500)
** Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same
OVER THE COUNTER PERMITTING (copy of contract required)
Reroofs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage)
Driveways-Not over Counter if on public roadways..needs ROW
r
tsuuamg ueparimeni ,
NOTICE OF DEED RESTRICTIONS:The undersigned understands that this permit may be subject to"deed"restrictions"which may be more restrictive
than County regulations.The undersigned assumes responsibility for compliance with any applicable deed restrictions.
UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES:If the owner has hired a contractor or contractors to undertake work,they
may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and
contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements
may apply for the intended work,they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847-8009.
Furthermore,if the owner has hired a contractor or contractors,he is advised to have the contractor(s)sign portions of the"contractor Block"of this
application for which they will be responsible.If you,as the owner sign as the contractor,that may be an indication that he is not properly licensed and is
not entitled to permitting privileges in Pasco County.
TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands
that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings,change of use in existing buildings,or
expansion of existing buildings,as specified in Pasco County Ordinance number 89-07 and 90-07,as amended.The undersigned also understands,that
such fees,as may be due,will be identified at the time of permitting.It is further understood that Transportation Impact Fees and Resource Recovery
Fees must be paid prior to receiving a"certificate of occupancy"or final power release.If the project does not involve a certificate of occupancy or final
power release,the fees must be paid prior to permit issuance.Furthermore,if Pasco County Water/Sewer Impact fees are due,they must be paid prior
to permit issuance in accordance with applicable Pasco County ordinances.
CONSTRUCTION LIEN LAW(Chapter 713,Florida Statutes,as amended):If valuation of work is$2,500.00 or more,I certify that I,the applicant,
have been provided with a copy of the"Florida Construction Lien Law—Homeowner's Protection Guide"prepared by the Florida Department of
Agriculture and Consumer Affairs.If the applicant is someone other than the"owner", I certify that I have obtained a copy of the above described
document and promise in good faith to deliver it to the"owner"prior to commencement.
CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with
all applicable laws regulating construction,zoning and land development.Application is hereby made to obtain a permit to do work and installation as
indicated.I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all
laws regulating construction,County and City codes,zoning regulations,and land development regulations in the jurisdiction.I also certify that
understand that the regulations of other government agencies may apply to the intended work,and that it is my responsibility to identify what actions I
must take to be in compliance.Such agencies include but are not limited to:
- Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive
Lands, Water/Wastewater Treatment.
- Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering
Watercourses.
- Army Corps of Engineers-Seawalls, Docks, Navigable Waterways.
- Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment,
Septic Tanks.
US Environmental Protection Agency-Asbestos abatement.
Federal Aviation Authority-Runways.
I understand that the following restrictions apply to the use of fill:
- Use of fill is not allowed in Flood Zone W" unless expressly permitted.
- If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a
"compensating volume" will be submitted at time of permitting which is prepared by a professional engineer
licensed by the State of Florida.
- If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall
construction, I certify that fill will be used only to fill the area within the stem wall. .
- If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent
properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating
the conditions of the building permit issued under the attached permit application, for lots less than one (1)
acre which are elevated by fill, an engineered drainage plan is required.
If I am the AGENT FOR THE OWNER,I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to
commencing construction. I understand that a separate permit may be required for electrical work,plumbing,signs,wells,pools,air conditioning,gas,or
other installations not specifically included in the application.A permit issued shall be construed to be a license to proceed with the work and not as
authority to violate,cancel,alter,or set'aside any provisions of the technical codes,nor shall issuance of a permit prevent the Building Official from
thereafter requiring a correction of errors in plans,construction or violations of any codes.Every permit issued shall become invalid unless the work
authorized by such permit is commenced within six months of permit issuance,or if work authorized by the permit is suspended or abandoned for a
period of six(6)months after the time the work is commenced.An extension may be requested,in writing,from the Building Official for a period not to
exceed ninety(90)days and will demonstrate justifiable cause for the extension. If work ceases for ninety(90)consecutive days,the job is considered
abandoned.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR
PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT
WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTI F COMMENCEMENT.
FLORIDA JURAT(F.S. 117.03)
OWNER OR AGENT CONTRACTOR _W_
Subscribed and sworn to(or affirmed)before me this Subscribed and swoivl.to<or affirmed)befo me this
by 12/1/20 by Seann Gates
Who is/are personally known to me or has/have produced Who is/are personall known to me or has/have produced
as identification. D as identification.
Notary Public Notary Public
Commission No. Commission No. GG 959064
Jason S. Monchgesang
Name of Notary typed,printed or stamped Name of Notary typed,printed or stamped
JASON S. MONCHGESANG —
Notary Public-State of Florida
• Commission N GG 959064
���p%�nna``�� MyFeb February 17n 024res
DocuSign Envelope ID:A61 FODCD-02EF-467F-824A-271 BODEBB86C
CONTRACT FOR SALE AND INSTALLATION OF A 6.08 SYSTEM
(hereinafter the"System")by and between US Solar Squared,LLC(hereafter"Seller"whose address is below provided)and
Nicolas Posada (hereinafter jointly or severally"Buyer")whose address is
39672 Dawson Chase Drive Zephyrhills Florida 33540 according to the terms and conditions hereafter stated. Buyer
understands and agrees that this contract is binding only when accepted by Seller by having its duly authorized company officer or member execute this
contract.Buyer further understands and agrees that the full contract price for purchase and installation of the System shall be the following price
$26-112.00 unless amended by subsequent agreement of the parties.Buyer further acknowledges and agrees that Buyer is not to give
the sales agent presenting me this contract any money or check as the sales agent is an independent contractor and is not authorized to collect
money on behalf of Seller.
TERMS AND CONDITIONS
MECHANIC'SLIENNOTICE: ACCORDING TO FLORIDA'S CONSTRUCTION LIEN
LAW (SECTIONS 713.001 - 713.37, FLORIDA STATUTES),THOSE WHO WORK ON
YOUR PROPERTY OR PROVIDE MATERIALS AND ARE NOT PAID IN FULL
HAVE A RIGHT TO ENFORCE THEIR CLAIM FOR PAYMENT AGAINST YOUR
PROPERTY IF YOUR CONTRACTOR OR SUBCONTRACTOR FAILS TO PAY
SUBCONTRACTORS, SUBSUBCONTRACTORS, OR MATERIAL SUPPLIERS. THE
PEOPLE WHO ARE OWED MONEY MAY LOOK TO YOUR PROPERTY FOR
PAYMENT, EVEN IF YOU HAVE ALREADY PAID YOUR CONTRACTOR IN FULL.
IF YOU FAIL TO PAY YOUR CONTRACTOR, YOUR CONTRACTOR MAY ALSO
HAVE A LIEN ON YOUR PROPERTY. THIS MEANS IF A LIEN IS FILED YOUR
PROPERTY COULD BE SOLD AGAINST YOUR WILL TO PAY FOR LABOR,
MATERIALS, OR OTHER SERVICES THAT YOUR CONTRACTOR OR A
SUBCONTRACTOR MAY HAVE FAILED TO PAY. TO PROTECT YOURSELF, YOU
SHOULD STIPULATE IN THIS CONTRACT THAT BEFORE ANY PAYMENT IS
MADE, YOUR CONTRACTOR IS REQUIRED TO PROVIDE YOU WITH A
WRITTEN RELEASE OF LIEN FORM ANY PERSON OR COMPANY THAT HAS
PROVIDED TO YOU A "NOTICE TO OWNER." FLORIDA'S CONSTRUCTION
LIEN LAW IS COMPLEX, AND IT IS RECOMMENDED THAT YOU CONSULT AN
ATTORNEY.
BUYER'S RIGHT TO CANCEL\
This is a home solicitation sale,and if you do not want the goods or services,you may cancel this contract by providing written
notice to the Seller in person,by telegram,or by mail.This notice must indicate that you do not want the goods or services and
must be delivered or postmarked before midnight of the third business day after you sign this contract. If you cancel this
contract,the seller may not keep all or part of any cash down payment.
Date Buyer signed this contract is: 11/12/2020 _. If Buyer decides to cancel this contract,Buyer will send the cancellation
notice to Seller at its address provided below within three business days after this date.
By signing below,Buyer agrees to the terms and conditions stated above and on the reverse side of this page.
Buyer(s): f lBoaerar e/g,Rouse must sign as well).
By. By
BiBssscoeA23asc...
ACCEPTANCE:By signing below,Seller hereby accepts Buyer's offer according to the terms and conditions stated above and on the reverse side.
DocuSlgned by:
US Solar Squared,LLC B
2732 Broadway Center Blvd. Seann Gates,Presi ent
Brandon,Florida 33510 20A494735B8B49A...
State License#CVC57002 Date Accepted 1 I/13/2020
CHAPTER 558 NOTICE OF CLAIM
CHAPTER 558, FLORIDA STATUTES, CONTAINS IMPORTANT REQUIREMENTS YOU MUST
FOLLOW BEFORE YOU MAY BRING ANY LEGAL ACTION FOR AN ALLEGED
CONSTRUCTION DEFECT. SIXTY DAYS BEFORE YOU BRING ANY LEGAL ACTION, YOU
MUST DELIVER TO THE OTHER PARTY TO THIS CONTRACT A WRITTEN NOTICE,
REFERRING TO CHAPTER 558, OF ANY CONSTRUCTION CONDITIONS YOU ALLEGE ARE
DEFECTIVE AND PROVIDE SUCH PERSON THE OPPORTUNITY TO INSPECT THE ALLEGED
CONSTRUCTION DEFECTS AND TO CONSIDER MAKING AN OFFER TO REPAIR OR PAY FOR
THE ALLEGED CONSTRUCTION DEFECTS. YOU ARE NOT OBLIGATED TO ACCEPT ANY
OFFER WHICH MAY BE MADE. THERE ARE STRICT DEADLINES AND PROCEDURES UNDER
THIS FLORIDA LAW WHICH MUST BE MET AND FOLLOWED TO PROTECT YOUR
INTERESTS. °
Installationl l.10
�t
DocuSign Envelope ID:A61 FODCD-02EF-467F-824A-271 BODEBB86C
1.INCORPORATION:The parties agree that the terms and provisions set forth on the front page are incorporated into this contract by reference.
2.JOB SPECIFICATIONS:The specifications for the System are set forth in the work order attached hereto and incorporated herein by reference.
The contract price set forth on the front page shall include i) the purchase of the System described in the work order; ii) the installation of the
System by Seller or its subcontractor, and iii) costs of supplies and materials used in the installation of the System. Buyer agrees to be fully
responsible for all sales taxes,if any,levied in connection with the purchase and installation of the System.Unless otherwise set forth in this contract,
the installation shall occur at the address of Buyer stated in the preamble.It is the obligation of the Buyer to provide Seller or its subcontractor utility
services so that Seller may properly install the System.
3. SERVICE AGREEMENT:Buyer agrees that this is not a contract governed under Chapter 672,Florida Statutes, as this is a contract primarily
for the installation of the System.Seller is not responsible for securing for Buyer any Federal Tax Credit,State or Power Company rebate,if any.
4. RESTOCKING FEE:Except for instances caused by US Solar Squared,LLC,US Solar Squared,LLC will charge the customer a restocking fee
of 15%for any cancellations after the recession period ends.
5.FINANCING:If Buyer does not have the funds readily available to pay the contract price following the installation of the System,Buyer agrees to
apply to a1mancing company to pay the contract price on forms provided by the financing company. Such application shall be undertaken by Buyer
independent of Seller whom Buyer agrees is neither Buyer's agent nor the agent of the financing company in connection with any loan application.If
Buyer applied for financing in connection with this contract, Buyer understands that Seller will not accept Buyer's offer unless the financing is
approved by a duly licensed financing institution in good standing in the State of Florida. If Seller accepts Buyer's offer and thereafter learns that the
financing has not been issued,or if issued is then withdrawn by the financing company, Seller may terminate this contract without any liability to
Buyer.
6.WARRANTY: Seller agrees,on condition that the full contract price has been paid on completion of the installation of the System,to warrant the
operation of the System for one year following its installation.If,during this one year period,the System or any its components should fail to operate
in accordance with the manufacturer's specifications, Seller agrees to replace or repair the System at its sole cost and expense, including parts,
supplies and labor.US Solar provides a 10 year Workmanship Warranty and a 5 year Roof Penetration Warranty.
7.LIMITATIONS OF WARRANTY:The warranty of repair and replacement given by Seller in paragraph 5 above shall be null and void if Buyer
or anyone else shall damage or improperly maintain or operate the System, or should injury or damage be caused the System by fire,rain, freeze,
storm(including hurricane)or any other force majeure or act of God.Furthermore,Buyer acknowledges and agrees that the proper maintenance and
operation of the System is dependent upon the conditions of proper design,construction and maintenance of Buyer's property and building(and pool
if applicable)where the System is to be installed and operated,and that the plumbing and electrical services serving Buyer's property are adequate to
maintain and operate the System as intended once installed. If the System fails to operate within the manufacturer's specifications because of the
failure of any of these conditions, then the warranty of Seller is null and void. Furthermore, it is specifically agreed that SELLER DOES NOT
PROVIDE AN IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE AS TO THE
SYSTEM BEING INSTALLED.
8. LIMITATION OF LIABILITY:The exclusive obligation and liability of Seller, and that of its officers,subcontractors,agents and employees,
to Buyer for any direct, indirect or consequential damages arising from or related to i) the failure of the System to operate according to the
manufacturer's specifications, or ii) damage to the property or building of Buyer due to a defect in the System or to the negligent or improper
installation of the System, or iii) for any personal injury (including death) caused Buyer by a defect in the System or its improper or negligent
installation is limited to the contract price;and,except to that extent,the Buyer hereby releases,discharges and waives any other claim or demand for
damages, injuries or losses of any kind or nature, or any other suit or action that Buyer may or does have against Seller, or any of its officers,
employees or agents,based upon a defect in the manufacture, installation or operation of the System, including any claim, demand, suit or action
Buyer might or could make or bring for the negligent installation of the System by Seller and its officers, subcontractors, agents and employees.
Furthermore, neither Seller nor any of its officers, subcontractors, employees or agents, shall be liable for any damage caused to the building or
property of the Buyer during the installation of the System unless Buyer serves written notice on Seller of the alleged damages within five(5) days
following installation.
9.ARBITRATION: Any dispute arising under or related to this contract,including any tort action arising out of or related to the installation of the
System,shall,if not resolved by the parties,be referred to binding arbitration.Only a court of competent jurisdiction shall have the right to determine
if the subject matter of the proposed arbitration comes within the terms of this arbitration provision if the parties disagree as to the arbitrability of the
matter. Arbitration shall be conducted in the Hillsborough County, Florida in accordance with Commercial Arbitration Rules of the American
Arbitration Association then pertaining, and judgment on any award rendered in such arbitration may be entered in any state or federal court. The
parties agree to allow the American Arbitration Association to choose the arbitrator,and its decision as to the selected arbitrator shall be binding
unless either party can show the chosen arbitrator to be incompetent or biased for or against any party.Notices in connection with such arbitration
must be served by personal delivery or certified mail, return receipt requested, on Seller at its address stated on the front page hereto. Costs of
arbitration, including the filing costs and related arbitrator fees, shall be awarded as determined by the arbitrator; but only a court having
jurisdiction over the parties may make a determination whether attorneys fees are recoverable, and if so, in what amount. Notwithstanding the
foregoing,the parties hereto,and those in privity with the parties hereto,agree that any action or suit to foreclose a mechanics lien brought pursuant to
Chapter 713,Florida Statutes,shall be exempt from the application of this arbitration agreement.
10. MERGER: This contract,if accepted by Seller,represents the final expression of the representations,terms and covenants of the relationship
established between Seller and Buyer and the installation of the System. Buyer agrees that Buyer is not relying upon any other representation or
statement made heretofore by any sales agent,independent contractor or representative of Seller to Buyer as an inducement to enter into this contract,
and Buyer releases Seller from any other inducement or representation that is not included herein, even if such representation was material to Buyer's
decision to enter into this contract.Buyer agrees that only an officer or member of Seller has the authority to bind Seller to this contract,or waive or
modify any of its terms.Furthermore,Buyer understands and agrees that no sales agent,independent contractor or employee of Seller has the right to
promise Buyer that any rebate of any sort will be made or given with respect to the purchase or installation of the System.
11.GOVERNING LAW,VENUE:This contract is to be construed under and governed by the laws of the State of Florida.Any action,suit or other
proceeding between the parties hereto, whether or not such action, suit or proceeding arises under this contract, shall be brought in Hillsborough
County,Florida; and the parties agree to waive venue in any other county.However, if the suit or action includes a mechanic's lien foreclosure,
venue shall be placed in the county where the System was installed.
12. NON-ASSIGNABILITY:Buyer may not assign this contract,nor any of Buyer's rights hereunder,to another.
13. PAYMENT:Buyer agrees to pay the full contract price on completion of the installation of the System,time being of the essence.
14. DEPOSIT:If the work order given in connection with this contract provides for Buyer to give Seller a deposit as a condition of Seller accepting
Buyer's offer, Buyer shall have the right to withdraw its offer if the amount of the deposit is not agreeable to Buyer. Payment of the deposit to
Seller's employee shall be conclusively deemed Buyer's agreement to enter into this contract and pay the deposit. Despite accepting such deposit,
Seller shall not be obligated to apply for any permit within thirty days of accepting the deposit or commence work within 90 days of the permit(s)
being issued,and the parties hereto waive application of Florida Statute§489.126(2)to the extent it applies to this contract,if at all.
15. ACCEPTANCE: If Seller does not provide notice to Buyer that Seller has accepted Buyer's offer within forty days following the date Buyer
signs this contract,Buyer's offer to enter into this contract shall expire.However, should Seller proceed to install the System following expiration of
the acceptance period with Buyer's knowledge and approval,then the parties hereto shall be bound by the terms of this contract.
Installation 11.10
2 1203899 13K 1OZZ JPG
02 1 oi- I
12,'02.'Z0?0 0'3-2,.3p,,i
-_-'32922 10.00
0 00 IT:
Permit No. Parcel ID No QL-1-9(2 ak-CM0VlJ(�oo39GO
NOTICE OF COMMENCEMENT
State of E1061*1210 County of �r 6
THE UNDERSIGNED hereby gives notice that Improvement will be made to certain real property,and In accordance with Chapter 713,Florida Statutes,
the following information Is provided in this Notice of Commencement
1. Description of Property: Parcel Identification No.
Street Address: AM C9 r+9-DAWSOVXC SQ ur,-Lepyk14'rMls V1_ S 65116
2. General Description of Improvement jZoa M0[AjaW ;<,0101r"Z) k
3. Owner Information or Lessee Information if the Lessee contracted for the Improvement:
'm i P-01 at, , ?050,m —
-gq&r4'2 D=Son C YWN)t FA=_
Address city State
Interest in Property: 06/.
Name of Fee Simple Titleholder.
(if different from Owner listed above)
Address city State
4. Contractor.
Address city State
Contractor's Telephone No.:
5. Surety:
Name
Address city State
Amount of Bond: $ Telephone No.:
6. Lender.
Name
Address city State
Lendet's Telephone No.:
7. Persons within the State of Florida designated by the owner upon whom notices or other documents may be served as provided by
Section 713.13(1)(a)(7),Florida Statutes:
Name
Address city State
Telephone Number of Designated Person:
8. In addition to himself,the owner designates of
toreceive a copy of the Lienor's Notice as provided in Section 713.13(1)(b),Florida Statutes.
Telephone Number of Person or Entity Designated by Owner.
9. Expiration date of Notice of Commencement(the expiration date may not be before the completion of construction and final payment to the
contractor,but will be one year from the date of recording unless a different date is specified):
WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT
ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13, FLORIDA STATUTES, AND CAN
RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE
RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING,CONSULT
WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT.
Under penalty of perjury,I declare that I have read the foregoing notice of commencement an hatthe facts stated therein are true to the best
of my knowledge and belief.
STATE OF FLORIDA
COUNTY OF PASCO
Signature of 9W-ror Lessee,or Owner's or Lessee's Authorized
Officer/Director/Partner/Manager
Wv"a QA9)c
Signatory's Title/Office
The foregoing Instrument was acknowledged before me this 121�dq of Alm 202g by A)iC aRS Pj0'%0,tAGL
_as i10011.9-OWyM_.r -(type of authority,e.g.,officer,trustee,attorney in fact)for
(name of pa behalf oLpA.m m.tru I was led).
Personally Known[3 QR Produced Identification)d Notary Signature
CI Z-
Type of Identification Produced Name(Print) _JCL5-'9',t :5-_Harlc_c�r_
JASON S. MONCHGESANG
Notary.Public-State of Florida
• Commission#GG 959064
My Commission Expires
wpdata/bcs/noUcecommencement_pcD53048 rrrnN February 17,2024
6.08 kW SOLAR ARRAY PLANSR
FOR 190 MODULES JECT DESCRIPTION:
SOLAR: MSE320SR8T GENERAL NOTES: No
'
19 INVERTERS - ENPHASE: 107-60-2-US 1. THIS IS TO CERTIFY THAT TO THE BEST OF
N I CO LAS P0 SA DA MY KNOWLEDGE AND BELIEF, THESE PLANS
CONFORM WITH FLORIDA BUILDING CODE 2017 O
GOVERNING CODES: WITH ALL SUPPLEMENTS AND ADDITIONS. �i
39672 DAWSON N CHASE DR 2017 FLORIDA PLUMBING CODE, 6TH EDITION 2. ALL PRODUCTS TO BE INSTALLED PER s
2017 FLORIDA BUILDING CODE, 6TH EDITION MANUFACTURER'S WRITTEN SPECIFICATIONS. ��
2017 FLORIDA MECHANICAL CODE, 6TH EDITION I, ANDREW D. HALL PE# 87479 AN ENGINEER ,``���
Z E P H Y R H I L LS FLORIDA 335 40 NEC 2014 LICENSED PURSUANT TO CHAPTER 471, CERTIFY
NFPA 1 2015 THAT THE PV ELECTRICAL SYSTEM AND
ELECTRICAL COMPONENTS ARE DESIGNED AND
APPROVED USING THE STANDARDS CONTAINED IN
THE MOST RECENT VERSION OF THE FBC, FBC
107.
TYP, EAVE
Wind Design Data
Wind Speed 140 mph
Risk Category 11
Exposure C
Gust Factor ±0.18
"A"Dimension 5.1 ft
Roof Pressure for Components and Cladding
Zone 1 16.47 psf -25.65 psf
Zone 2 16.47 psf -44.55 psf
Zone 3 16.47 psf -66.15 psf
n a
DISCONNECT
MIN. 4' CLEARANCE
PER NEC 110.26(A)
h qV ak"'iIIuIIiii
x' a
GYP_ RIDGE R '
ALL WORK SHALL COMPLY WITH PRt VA1 ING
CODES FLORIDA BUILDING COt)E,
NATIONAL ELECTRIC C00E,
AND THE CITY OF ZEPHYRHILLS
ORDINANCES
REVIEW DATE DEC 9
CITY OF ZEPHYRHILL 2020
EXAMINER
DRAWING INDEX:
LP
S-1 COVER
S-2 ARRAY LAYOUT & DETAILS
S-3 ELECTRICAL
GYP. EAVE MISSION SOLAR: S-4 NOTES
MODULE ROOF LAYOUT MSE320SRBT(OYP) S-5 SPECIFICATIONS
S-6 SPECIFICATIONS
S-7 SPECIFICATIONS
S-8 SPECIFICATIONS
♦i �./"jC"
,�• Na
S74�
PV MODULE QMR-UMC
CLIP
_______ri I __
3/8"-16 X 3/4" HEX HEAD BOLT QMR
O; CROSSRAIL LIGHT
3/8" - 16 FLANGE NUT (TYP)
SUNMODO NANO SUNMODO NANO
RAFTER MOUNT QMR RAFTER MOUNT
(np) CROSSRAIL LIGHT (TYP)
TOP VIEW
EXISTING UNDERLAYMENT NTS
EXISTING ROOF TRUSS
1/2" PLYWOOD
5/16" DIA SS LAG SCREW
2-1/2" EMBED MIN. TYPICAL SHINGLE ROOF ATTACHMENT
NTS
\ _______ _______ ______ _______ _____ _______ _______
SUNMODO NANO RAFTER MOUNT 48" MAX. O.C. QMR-UMC CLIP
(np) (np) QMR-UEC CLIP
(TYP)
w �
QMR-UEC MISSION SOLAR: MISSION SOLAR:
(�P) MSE320SR8T QMR-UMC CLIP MSE320SR8T
(TYP) (TYP) (TYP) ¢ w
w
QMR-UMC CLIP QMR-RL14 (TYP) QMR-UEC CLIP
SUNMODO NANO RAFTER MOUNT (TYP) TYPICAL LAYOUT (TYP)
(TYP) NTS
*. No
O . ST,T
Ii
#10 THWN-2 (3 CONDUCTOR) NOTE:
3/4" EMT, FMC, FOR EXTERIOR ALL INVERTERS ARE EQUIPPED
APPLICATION USE PVC OR W/ INTERNAL RAPID SHUTDOWN
LFMC/LFNMC CONDUIT #10 THWN-2 (3 CONDUCTOR)3/4" EMT, FMC, FOR EXTERIOR SYSTEM PER NEC 690.12
LOCKABLE FUSED APPLCATION USE PVC OR
MISSION SOLAR: MSE32OSR8T
PV AC DISCONNECT LFMC/LFNMC CONDUIT ENPHASE Q CABLE
30A 240V 2-POLE #10 THWN-2 (3 CONDUCTOR) ENPHASE Q CABLE 0-12-10-240 W/ ENPHASE IQ7-60-2-US
30A RK-1 FUSE 3/4" EMT, FMC, FOR EXTERIOR Q-12-10-240 (-yP) INVERTER
APPLCATION USE PVC (TYP)
OR LFMC CONDUIT
N L2 L1
METER AC AC
O L1 L1 ____ __
DC DC
L2 L2 N0. 1 NO. 10
N N SPACE I 20
SPACE
20 MR-RL14 (TYP)
20
NO. 1 NO. 9 NOTE:
ALL STRINGS TO HAVE
[#6 THWN-2 G AC1'\AC TERMINATORS & SEALING CAPS
DC DC INSTALLED PER MANUFACTURER'S
30 SOLADECK COMBINER BOX SPECIFICATIONS
NEUTRAL GROUNDFl 1 600V/ NON-FUSED
OR
SOLTECTION RESIDENTIAL
TRANSITION BOX ENPHASE 0 CABLE MISSION SOLAR: MSE320SR8T
GEC BOND AT Q-12-10-240 W/ ENPHASE IQ7-60-2-US
ENPHASE IQ COMBINER PLUS RACKING SYSTEM (hp) INVERTER
W/ (2) 20 AMP BREAKER (SEE NOTE #2)
NEUTRAL GROUND
AC PANEL 150 AMP/240V
6�O
Na
S7
NOTES:
1. ALL ASPECTS OF THE ELECTRICAL WORK REQUIRED TO COMPLETE THE PROJECT REPRESENTED IN THIS DOCUMENT
MODULE SPECIFICATION INVERTER SPECIFICATION SHALL COMPLY WITH THE MANUFACTURERS RECOMMENDATIONS/SPECIFICATIONS AND ALL CODES, STATUES AND
MODULE MAKE MISSION SOLAR INVERTER MAKE ENPHASE STANDARDS ADOPTED BY THE STATE AND THE LOCAL AUTHORITY HAVING JURISDICTION. ►
2. ALL COMPONENTS MUST BE GROUNDED PER NEC 690.43.
MODULE MODEL MSE320SR8T INVERTER MODEL IQ7-60-2-US
3. ALL EQUIPMENT SHALL BE LISTED PER NEC 690.4(D).
FSEC CERTIFICATION II MAX AC POWER OUTPUT 250 VA 4. THE INFORMATION PROVIDED IN THESE DOCUMENTS IS NOT EXHAUSTIVE. IT REMAINS THE CONTRACTORS
PMAX (STC) 320 W MAX. INPUT VOLTAGE 48 V RESPONSIBILITY TO ACHIEVE THE PROPOSED INSTALLATION, IN FULL EXERCISE OF AND COMPLIANCE WITH THE
VOC (STC) 40.80 V NOM. DC VOLTAGE ® 240V 240 V ITEMS IDENTIFIED IN NOTE 1.
VMPP (STC) 34.22 V NOM. AC VOLTAGE 16-48 V 5. PER NEC 690.17 PROVIDE A WARNING SIGN AT ALL LOCATIONS WHERE TERMINALS OF THE DISCONNECTING
MAX. CONTINUOUS OUTPUT CURRENT 1.00 A MEANS BE ENERGIZED IN THE OPEN POSITIONS. SIGN SHALL READ "WARNING-ELECTRIC SHOCK HAZARD - DO
ISC (STC) 10.03 A NOT TOUCH TERMINALS - TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN
IMPP (STC) 9.35 A MAX. DC CURRENT 15.0 A POSITION OR EQUIVALENT.
NOCT 46 C MAX. DC POWER (STC) 350 W 6. PER NEC 705.10, PROVIDE A PERMANENT PLAQUE OR DIRECTORY SHOWING ALL ELECTRIC POWER SOURCES ON
TC ISC 0.039 %/C CEC EFFICIENCY 97 % THE PREMISES AT SERVICE ENTRANCE.
TC VOC -0.280 7. INTERCONNECTION METHOD SHALL COMPLY WITH NEC 705.12.
TC PMPP -0.377 %/C 8. PV METER MAY OR MAY NOT BE REQUIRED BY THE AHJ AND/OR UTILITY FOR INTERCONNECTION.
9. CONDUCTOR SIZING OF THIS DESIGN IS BASED ON RACEWAYS LOCATED OUTSIDE ATTICS OR NOT EXPOSED
OPERATING TEMP. -40-+85 C TO DIRECT SUNLIGHT. WHERE TWO DIFFERENT AMPACITIES APPLY TO ADJACENT PORTIONS OF A CIRCUIT, THE
HIGHER AMPACITY SHALL BE PERMITTED TO BE USED BEYOND THE POINT OF TRANSITION, A DISTANCE EQUAL TO
3.OM (10ft) OR 10 PERCENT OF THE CIRCUIT LENGTH FIGURED AT THE HIGHER AMPACITY, WHICH EVER IS LESS.
NEC 310.15 (B)(2)
SAFETY LABELS AND MARKINGS GENERAL NOTES: I V AN V EMERGENCY CONTACT 10.ALL CONDUCTORS AND RACEWAYS SHALL BE SUPPORTED ON INTERVALS AND BY METHODS REQUIRED BY THE
NEC.
1 EQUIPMENT
E LABELS FOUND HEREIN SHALL B SUCH
INVERTERS
MODULES APPLIED TO SUCH U S SOLAR 12.PV ARRAY INTERCONNECTION TO BE MADE WITH BACK-FEED BREAKER.
PRE-APPLIED
13.GFI BUILT IN TO ALL INVERTERS.EQUIPMENT 2. LABELS FOR INFORMATIONAL
ANDMARKINGSSHALL BE APPLIED TO COMPONENTS IN 1 -813-4 3 4-0284
ACCORDANCE WITH THE CURRENTLY ADOPTED EDITION OF NEC.
3. ALL REQUIRED PRODUCT SAFETY AND WARNING SIGNAGE SHALL BE UV
RESISTANT OUTDOOR-RATED LAMINATED VINYL IN ACCORDANCE WITH
ANSI Z535.4-2011.
SAFETY LABELS AND MARKINGS LEGEND
A. LOCATION OF SERVICE DISCONNECTING MEANS. APPLY TO MAIN
SERVICE DISCONNECTING MEANS AND PV DISCONNECTING MEANS AT
POCC.
MAIN SERVICE DISCONNECT MARKING \ CAUTION SOLAR PHOTOVOLTAIC SYSTEM
,'4"\.
A LABEL SHALL BE PERMANENTLY AFFIXED TO THE MAIN SERVICE Ai -WARNING-
DISCONNECT PANEL SERVING ALTERNATING CURRENT (AC) AND DIRECT THIS SERVICE IS SUPPLIED BY MULTIPLE _WARNING_ ELECTRIC SHOCK HAZARD.THE DG
SOURCES. SEE DISCONNECTS BELOW. AUTHORIZED PERSONNEL ONLY CONDUCTORS OF THIS DAIC
CURRENT (DC) PHOTOVOLTAIC SYSTEMS. THE LABEL SHALL BE RED WITH SYSTEM ARE UNGROUNDED D AND
IN LEAST 3/4 . IN HEIGHT AND IN A RATED AC CURRENT: 23.8A MAY BE ENERGIZED
WHITE CAPITAL LETTERS AT
AUTHORIZED PERSONNEL ONLY
NONSERIF FONT, TO READ: "WARNING: PHOTOVOLTAIC POWER SOURCE." NOMINAL AC VOLTAGE: 240V
LOCATION: DISCONNECTS, INVERTERS,
THE MATERIALS USED FOR THE LABEL SHALL BE REFLECTIVE, WEATHER LOCATION: MAIN PV PANEL JUNCTION BOXES, OTHER ENCLOSES
RESISTANT, AND SUITABLE FOR THE ENVIRONMENT. w Ac o4sc0NNECT HOLDING DO CONDUCTORS
CIRCUIT DISCONNECTING MEANS MARKING
A PERMANENT LABEL SHALL BE AFFIXED ADJACENT TO THE CIRCUIT PHOTOVOLTAIC DISCONNECT
BREAKER CONTROLLING THE INVERTER OR OTHER PHOTOVOLTAIC SYSTEM
ELECTRICAL CONTROLLER SERVING AC AND DC PHOTOVOLTAIC SYSTEMS.
_ A /4\
THE LABEL SHALL HAVE CONTRASTING COLOR WITH CAPITAL LETTERS AT I I -WARNING-
LEAST 3/8 IN. HEIGHT AND IN A NONSERIF FONT, TO READ: ELECTRIC SHOCK HAZARD PHOTOVOLTAIC SYSTEM EQUIPPED
"PHOTOVOLTAIC DISCONNECT." THE LABEL SHALL BE CONSTRUCTED OF wARRAY DO NOT TOUCH TERMINALS.TERMINALS ON WITH RAPID SYSTEM SHUTDOWN
BOTH THE UNE AND LOAD SIDES MAY BE
DURABLE ADHESIVE MATERIAL OR OTHER APPROVED MATERIAL. ENERGIZED IN THE OPEN POSITION.
LOCATION: AC DISCONNECT(S)
'�• N°`
PERC 60CLASS LEADING ;41 -`325VJ ""cJ
Enphase IQ 7 and IQ 7+Microinverters
Electrical Parameters at Standard Test Conditions(STC) INPUT DATA(DC) 107-60-2-US 107PLU5-72-2-US I,
Module Type MSE31SSIt8T MSE32OSR8T RRSE82SSRST IEC Cbmrteeatty Used nurdufe pairings' 235W-350 W+ 235W-440W+
Power Output Pmax Wp 315 320 325 61215-61730-61701-Salt mist Module compatibility 60-cell PV modules only 60-cell and 72-cell PV modules
Module Efciency !B 19.24 Maximum input DC voltage 46 V fa0 V
UL Peak power tracking voltage 27V-37V 27V-45V
Tolerance 0'+3% 0"+3% 0+3% UL 1703 listed Operating range 16V-48V 16V-60V _
Stnrt#-Circuit Cutit ' r A 9.997 10.028 10-05D ................................................................................_..._.................. Min/Max start voltage 22V/48V 22V/60V
Open Circuit Voltage Voc V 40.44 40.80 41.14 erns CEC Meii DL shot circuit current(mf Jule lac/ 15 A 15 A
RatadCurrent In-p A 9.253 9.351 9.387 reran �. Overvoltage class DC port II 11
Rated Voltage Vmp V 34.04 34.22 34.62 DC port backfeed current O.A D A
20 2D 20 PV array configuration 1 x 1 ungrounded array;No additional DC side protection required;
Fuca Rating AC side protection requires max 20A per branch circuit
OUTPUT DATA(AC) IQ 7 Microinverter IQ 7+Microinverter
Peck output power 2.50 VA 295 VA
MSE320SR8T:320WP,60 CELL SOLAR MODULE Maximum continuous output power 240 VA 290 VA
Normal Operating Call Temperature(NOCT) 48.09°C(t2°C) CURRENT-VOLTAGE CURVE Norninal(t-1..)voltage/rangev 740V/ 208V7 240V/ 7O8 V/
/
211-264 V 183-22911 211-244 V 1 +229 V
Temperature Coefficient of Pmax -0.377%l°C
iz Maximum continuous output current 1,OA 1,15A 1.21 A 1.39 A
Tomperature Coefficients:'Voe -0280%/'C ; Cee1emp.=2s e Nominal frequency 50 hl:. 50 Hz
Tern rature Coefficient of Ise 0.039%/°C It . Incident.._...rrrd.=.1Oo5W/ntz.........,
Pe "' "" Extended frequency range 47-68 Hz 47-68 Hz
C ,g.;.... .....µ iirtet .irrd, .gep wfmx........ ..........
AC short circuit fault currant over 3 cycles 5 SArms 5.8 Alms
e. > e e Maximum units per 20 A(L-L)branch circuit' 16(240 VAC) 13(240 VAC)
octant 13(208 VAC) 11(208 VAC)
-lrrd.61r0 yY/rt?. ..
Maxtmurn System Voltage 1,000VdC u s ,` Overvrrltage class AC port ill fit -
Operating Temperature Range -40°C(-40°F)to+85°C(185'F) '< 3.... reidanf i d aas w/m?.., c„ AC port backfeed current 0 A 0 A
Maximum Series Fuse Rating 20A 2 Povier factor setting le4 [:1J
Incident )ird 200 WIm 1
., Power factor(ad)ustahie) 0.7 leading...0.7lagging 07 leading...0.7lagging
Fire Safety Classification Type 1,Class C � EFFICIENCY @240 V @208 V @240 V @208 V
front&Back Load(UL standard) 5631 P8(117 psi) e •..... ... .. ...... ... ......... .. . ... ......... P ek:FC efflclaru:y ct7 5% 47 6 97.5% 97.313
Tested to UL1703 standard o t° z° r✓ CEC weighted efficiency 97.0% 97.0% 97.0% 97.0%
Hall Safety Impact Veloe 25mm at 23 m/s Voltage(1/J
Pa ItY MECHANICAL.DATA IQ 7 Microinverter
Current-voltage characteristics with dependence on irradiance --and module temperature TAmbierit temperature range -40°C to+65'C
Relative humidity range 4%to 100%(condensing)
Solar Celts P-type mono-crystalline silicon (168 75mm) Connector type M04(or Amphenol H4 UTX with additional Q-DC(-5 adapter)
Cell Orientation 60 cells(6x10),5 busbar BASIC DESIGN(UNITS:mm) Dimensions(WxHxD) 212 mm x 175 mm x 30.2 mm(without bracket)
1676,nm x 1008mm x 40mm We 1.08 kg(2 38 the)ight
Module Dimension (65 98 in.x 39.68 in,x 1.58 In.) �a Cooling Natural convection-No fans
Weight 20 kg(441b) 3s 3s Approved for'wet iocatlons Yes
Pollution degree PD3
Fro rt Glass 3 2mm(4,126 in.)tempetwd, I1flhIIiIllIIIIIIIIIIFIHDIl r
`, s°° 4nc iovrire Class 11 dvubl!t insta ated,corrosion res;stannt polymeric enciosure
law-iron.anti-reflecbvo coating i av
Environmental category/UV exposure rating NEMA Type 6/outdoor
Frame Anodized aluminum alloy
FEATURES
Encapsutant Ethylene vityl acetate(EVA) lliiJIII!II1II1IIIIIIIIDF!I II aWn°^9
Crnraunicatfon Pnrrer Line Communication( LG) —
J-Box Protection class IP67 with 3 bypass-diodes we Monitoring Enlighten Manager and MyEnlighten monitoring options.
ll-lll-#l-I1IIIIIU-IIllIHI 111111111 Both options require installation of an Enphase IQ Envoy.
Cables faV vlrre.9m(3937th.),4mm2112 AWGill II llh1IIIDII1llhI 1 D.IcOtnecting means The AC and DG connectors leave been evaluated and epprbtieed by UL for use es the load-break
Connector MC4 Compatible disconnect required-by NEC 690.
Compliance CA Rule 21(UL 1741-SA)
UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B. ICES-0003 Class B,
■' +s g CAN/CSA-022.2 NO.107.1-01
This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and
Container FT Paileta Panels 320W NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems,for AC
°0O and DC conductors,when installed according manufacturer's instructions,
53• Double stack 36 936 299.52 kW Front View Back View 1.No enforced DC/AC ratio.See the compatibility calculator at bUa Ll�nphasQ m/an.iis t RAs[tlofodsi e�gmus ib ty.
D Double slack 28 726 23296 kW 2.Nomlral voltage range can be extended beyond nominal if required by the utility.
3.Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area.
Panels Weight Height Width Length
Pallet 26 1,1961bs 42.46" 45,50' 01 :Y • To learn more about Enphase offerings,visit enphase.com EN PHASE
MISSION SOL/\R ra:2018 tnphavt Energy.11i rights resc v5/..Al trademarks ca-brands used are the praperty of Enphaac Energy,Ina
ENERGY as ' 2!'113-02-CS
Mission Solar Energy reserves the right to make specification changes without notice Mission Solar Energy 18303 S.New erauntels Ave.,San Antonio,Texas 79235
ecc'jucsl e,c url.V.'`..;Ala H 9:'?N V:e2 ?EVI:.:IN:.AiS'".21.:C7
- infot+missionsolaccom I www.missionsoiaccom
O'
Enphase Q Cable Accessories Enphase IQ Combiner 3
MODEL.NUMBER
Q AGGREGATOR SPECIFICATIONS lt)Cumblr er 3 IQ Combiner 3 with Enphasa IQ Envoy'printed cecait 17uard for a rtegrate rseenue gimie r'V
Q Agar sgator Q EA-3 1P-60(stngirs pirtrst).Comtines up is fh ee in tr utrt enter tEren hies inia one home run. X-lQ-AMI-240.3 production metering(ANSI C12.20+1-0 5%)and up Onrtai,consumption moni aring{+,'•2 5 t
Protect with maximum 60 A,2-poteCCPL ACCESSORIES and REPLACEMENT PARTS(not included,order separately)
Q Commercial Aggregator Q-BA-3-3P-35(three-phase).Combines up to three,single-phase microinverter branches into a three- Enphase Mobile Connect'"
phase home run.Protectwi₹h maximum 40 A,3-pole OCPD. CELL MODEM-03(40/12-year data plan) Plug and play Industrial grade cellular modern with data plan for systems up to 60
CELLMODEM-01(SG/S-year data plan) microinverters.(Available in the US,Canada,Mexico,Puerto Rico,and the US Virgin Islands,
Dimensions 190 mm(W)x 227 mm(O)x 80 min(H)(7.5 in(W)x 9 in(0)x 3.2 in(H)} CELLMODEM-M1(40 based LIE-MI5-yew data plan) whereihere is adequate cellular service in the installation area.)
Homerun conductor size range #12 to#4 AWG Consumption Monitoring*CT Split core current transformers enable whole home consumption metering(+/-2.5%).
CT 200,SPLIT
Entinelirerating NEMAS Cup to 45'from horizonialj ,i 'Conwirsuanmonitoringisreduired!orEnptui'.e5tcrage Syrian's
.
Wireless USB adap*sr Installed atihe IQ Envoy.For communlcattons with Enphase Encharge°storage ants Enphase
Temperature range 40°C to+55°C(•40°F to+122'F) COMMS-KIT 01 Enpower"smart switch Includes USB cable for connection to IQ Envoy or Enphase IQ Combiner'
Compliance UL1741(assembled product)and UL6703(bulkhead connectors) arid allows redundant wireless communication with Ericharge and Enpower
Circuit Breakers Supports Eaton BR210,8R215,BR220,BR230,BR240,BR250,and BR260 circuit breakers.
CONDUCTOR SPECIFICATIONS BRK-10A-2-240 Circuit breaker,2 pole,10A,Eaton BR210
Certification UL3003(raw cable),UL 9703(cattle assemblies),DC cable BRK-15A-2-240 Circuit breaker,2 pole,15A,Eaton BR215
Flame test rating iFT4 BRK-20A-2P-240 Circuit breaker,.2 pole,20A,Felon BR220
EPLC-01 Power line carrier(communication bridge pair),quantity-one pair
C`etnplii;nae RoHS,OIL REt et,t3V teplstsnt.combined UL for the Units/States
XA-PLUG-120-3 Accessory receptacle for Power Line Carrier in IQ Combiner 3(required for EPLG-01)
Conductortype THHN7THVwN-2 dry/wet
Disconnecting means The AC and DC bulhead connectors heve been evaluated anal approved by UL for use as th;:load=break XA-LNV-PCBA-3 Replagement IQ Envoy printed circuit board(PCB)for Combiner 3
diaconneot required byy NEC 690 ELECTRICAL SPECIFICATIONS
Q CABLE TYPES 1 ORDERING OPTIONS
Rating Continuous duty
Model Number Max Nominal Voltage Connector Spacing PV Module Orientation Connector Count per Box System voltage 120/240 VAC,60 Hz
012-10-240 27.7 VAC 1.,3 m(4.2 fi} Portrait '240• Eaton BR serie.,bustearratingg 125 A
Q-1217-240 277 VAC 2.0 m(6.5 ft) Landscape(60-cell) 240 Max.continuous current rating(output to grid) 65 A.
Q t7.2V 2a0 277 VAC 2.3 m(7.5 ft) Landscape(72-cell) 200 Max.fuse/circuit rating(output) 90 A
ENPHASE 0 CABLE ACCESSORIES Branch circuits(solar and/or.storage) Up to four 2-pole.Eaton BR series Distributed Generation(DG)breakers only(not included)
Name Model Number Description — Max.Curflntrous current ratmg(Input from PV) 64 A
1dewQ Cable Q-12-RAW-200 300 meters of 12 AWG cal le with no connectors Max.total branch circuit breaker rating(input) 80A of distribi ted generation 7 90A with IQ Envoy breaker included
Field-wi€eable connector(male) Q-CONN-10M Make connections from any Q Aggregator open connector Prorkuctdon Metering CT 200 A solid core pre-installed and wired to IQ Envoy
Fiendvrireable connector(female) Q-CONN-1oF Make connections frettcaany Q Cable open connector MECHANICAL DATA
Cable Clip Q-CLIP-100 Used to fasten cabling to the racking or to secure looped cabling Dimensions fWxHxb) 49.6 x 37.5 x 16.8 csm(196x14 14 7 'r 663") 14eight Ia`,?1.06'(55. cm with mounting ttraske;M)
Disconnect tool Q U'Sc 10 )taro inect tool for 0 Cable corx:actm t•C--onnsctn*3,ynd AC module mount Weight 7.5 kg(16,5 Ibs)
0 Aggregator sealing caps(male) Q-BA-CAP-10 Seahny cap for unused aggi egator canoe i rc,n Arnbe nt temperature range 40°C to+46°r.(4t3°to 115"F)
O Cable sealing raps(female) Q-SEAL-10 One needed to corer n ch unused connector on the cabling Cooling Natural convection,plus heat shield
Terminator C-TERM-to Terminator cap for unused cable ends Enclosure environmental rating Gutdoot,NRTL-ceritfted,NEMAtype 3R,polycarbonete construcno?t
Replacement DC Adaptor(MCsil Q-DCC-2 DC adaptor to MC4(max voltage 100 VDC) Wire sizes 20 A 10 50 A breaker inputs: 14 to 4 AWG copper conductors
60 Abreaker branch input:4 to'1/0 AWG copper conductors
Replacement DC Adaptor(UT)( Q•DCC-S DC adaptor to UTX(max voltage 100:VDC) Main lug combined output: 10 to 2/0 AWG popper conductors
• Neutral and ground: 14 to 1/0 copper conductors
Always follow local code requirements for conductor sizing.
TERMINATOR S@AnINGCAPS 7o 2000 meters(5,560 feet) >
Terminatords solin for unusednd cable Sealing o oned aggregator INTERNET CONNECTION OPTIONS
ends,sold in packs often and cable connections W-
(0-TERM-t0) (Q-BA-CAP-10 and Q-SEAL:10) Iritagrateif Wl±i 2.11ti1g/n
Ethernet Optional,802.3,CatSE(or Cat 6)UTP Ethernet cable (not included)
Celular Optional,CFLLMODEM-01(3G)orCELLM0DEM-03(4G)orCFtLMODFf,4-M3 as(4GbedLTE-M) `
DISCONNECT TOOL CABLE CLIP of Inciudedi
Plan to use at least one per Used to fasten cabling to the racking COMPLIANCE
installation,sold in packs of ten or to secure looped cabling,sold in —
(Q-DISC-10) packs of ten(Q-CLIP-100) Cc�npii�t ce,Cant roar UL 1741 cAN!C A 022.2 No 1071 47 CIR,Part 15 Class 5,ICES 003
Production metering-ANSI C12 20 accuracy Class U 5(PV production)
Compliance,IQ Envoy UL 60601-1/CANCSA 22.2 No,61010-1
To learn more about Enphase offerings,visit enphase.com
To learn more about Enphase offerings,visit enphase.com 02013 Fnphasc E,orgy.All ng'its rase:ved.Eephase,the Ensi use lag:>,IQ Connbiner 3,and othertrademarks or sen-s-c earls are the
0 2018 Enphase E.'vrgy.A:1 rigor;reserved.All trademarks or brand:;used ore the property of Enphase Fwr,y.Inc. e ENPHASE, todenrarks of E::pl ase Energy,Inc. ENPHASE.
201]-1 14'14
201 Vl1-(73
*• Nod
• - . • . SUNMOMADo���
5 levels of protection. against Aesthetically pleasing
• unibody aluminum cast
SOLAR'S
F water penetration construction
A
360-degree positioning,
serrated surface on both
ATTACHMENT
sides for rail mounting
• #' t.
Versatile mounting option
includes direct-to-decking
for fast installation
• . '•
• Integrated Ultra Soft
Weather Resistant
ti silicone gasket
Alignment markers
i a a' s ■ - The NtlnoMounf Advantage enable easy installation
• * ' _ # ' ' .f The fastest roof attachment in
• solar
Versatile mounting options
y` ' including direct-to-decking
. , : , Eliminates the need to lift
* a ` shingles and prevents damage to 7Apcotion Composite shingle and rolled asphalt
shingle l High grade aluminum, 304 stainless steel hardware
• High-Velocity Hurricane Zone Finish Black powder coating
Approved - Passed TAS 100 (a) Roof Attachment Rafter and decking
Wind-Driven Rain Test Structural integrity IBC and IRC Compliant
,/ All materials are compatible with Warranty 25 years
roof shingles —SunModo, Corp.Vancouver, WA., USA • www.sunmodo.com * 360.844.0048 + infa@sunmodo.com
Structural quick Mount PVC
gip'
ENG U T c RESPECT THE ROOF
Ingenuity in Engineering
Rail Spans for Quick Mount PV QRaiI Light System
Mean Roof Height: 0<h≤15 ft Panel Orientation: Portrait
Table 3 Roof Angle: 7<0 ≤27 degrees
Exposure Category: C
Roof Ground Wind Speed(mph)
Wind Snow
Zone Load 100 110 115 120 130 140 150 160 170 175 180 190
0 81 81 81 81 81 76 71 66 52 60 59 55
10 T6 75 74 73 71. 69 67 66 67 60 59 55
20 61. 61 61 61 60 59 58 56 55 55 54 53
30 52 52 52 52 52 52 51 50 50 49 49 48
Zone 40 45 45 45 45 45 45 45 45 45 45 45 44
1 50 41 41 41 41 41 41 41 41 41 41 41 41
60 38 38 38 38 38 38 38 38 38 38 38 38
70 35 35 35 35 35 35 35 35 35 35 35 35
80 33 33 33 33 33 33 33 33 33 33 33 33
90 31 31 31 31 31 31 31 31 31 31 31 31
0 78 70 67 64 59 55 5 48 45 43 42 40
10 76 70 67 64 59 55 51 48 45 43 42 40
20 61 61 61 61 59 55 Si 48 45 43 42 40
30 52 52 52 52 52 52 Si 48 45 43 42 40
Zone 40 45 45 45 45 45 45 45 45 45 43 42 40
2 50 41 41 41 41 41 41 41 41 41 41 41 40
60 38 38 38 38 38 38 38 38 38 38 38 38
70 35 35 35 35 35 35 35 35 35 35 35 35
80 33 33 33 33 33 33 33 33 33 33 33 33
90 31 31 31 31 31 31 31 31 31 31 31 31
0 62 56 54 52 48 44 41 38 36 35 34 32
10 62 56 54 52 48 44 41 38 36 35 34 32
20 61 56 54 52 48 44 41 38 36 35 34 32
30 52 ,52 52 52 48 44 41 38 36 35 34 32
Zone 40 45 45 45 45 45 44 41 38 36 35 34 32
3 50 41 41 41 41 41 41 41 38 36 35 34 32
60 38 38 38 38 38 38 38 38 36 35 34 32
70 35 35 35 35 35 35 35 35 35 35 34 32
80 33 33 33 33 33 33 33 33 33 33 33 32
90 31 31 31 31 31 31 31 31 31 31 31 31
Notes:
1. Tables are based on critical rail span for load combinations as specified in chapter 2 of the ASCE 7-10 and
allowable design loads per the 2015 Aluminum Design Manual.
2. Panels are assumed to be in portrait orientation with a maximum length of 67.5"
959 Larchmont Court,Aurora,IL 60504 3/4/2019
630-219-1997{P)
www.structuralenginuityinc.com C3