HomeMy WebLinkAbout20-1190 ►�►>I� ,.,: City of Zephyrhills 11111111111118ERMIT NUMBER 5335 Eighth Street Zephyrhills, FL 33542 BNR-001190-2020 • Phone: (813)780-0020 �.. Fax: (813)780-0021 Issue Date: 01/14/2021 Permit Type: Building New (Residential) Prop�0 Number Street Address 32 25 210040 01300 0130 7054 Steer Blade Drive Owner Information Permit Information Contractor Information Name: D R HORTON Permit Type:Building New(Residential) Contractor: D R HORTON INC Class of Work:SFR Construct Address: 12602 Telecom Dr Building Valuation:$160,000.00 TAMPA,FL 33637 Electrical Valuation:$8,200.00 Phone: (813)549-1968 Mechanical Valuation:$6,000.00 Plumbing Valuation:$9,500.00 Total Valuation:$183,700.00 Total Fees:$14,770.94 Amount Paid:$14,770.94 _ Date Paid:1/14/2021 1:40:20PM Puoject Description CONSTRUCT SINGLE FAMILY 3,713 SQ FT-SILVERADO Application Fees SIF 1 percent Fee $83.28 Mechanical Plan Review Fee $35.00 Public Safety Impact Fee-Admin $26.35 Electrical Plan Review Fee $40.50 Building Plan Review Fee $415.00 School Impact Fee $8,328.00 Electrical Permit Fee $81.00 Mechanical Permit Fee $70.00 Public Safety Impact Fee-Police $254.00 Park Impact Fee-Single Family/Townhome $769.56 Driveway Fee $45.00 Plumbing Permit Fee $87.50 Transportation Impact Fee $3,595.68 Transportation Impact Fee-City $36.32 Plumbing Plan Review Fee $43.75 Building Permit Fee $830.00 Address Fee $30.00 REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each subsequent reinspection. Notice: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permit required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner:Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications add fee Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. CONTRACTOR SIGNATURE PE IT OFFICE PERMIT EXPIRES-IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER INVOICE1111 • ' CITY OF BILLING CONTACT DAVID GUDE D R HORTON INC 12602 TELECOM DR TAMPA, FL 33637 I INVOICE NUMBER INVOICE DATE INVOICE DUE DATE INVOICE STATUS INVOICE DESCRIPTION INV-00002433 01/11/2021 01/11/2021 Due NONE REFERENCE NUMBER FEE NAME TOTAL BNR-001190-2020 Address Fee $30.00 Building Permit Fee $830.00 Building Plan Review Fee $415.00 Driveway Fee $45.00 Electrical Permit Fee $81.00 Electrical Plan Review Fee $40.50 Mechanical Permit Fee $70.00 Mechanical Plan Review Fee $35.00 Park Impact Fee-Single Family/Townhome $769.56 Plumbing Permit Fee $87.50 Plumbing Plan Review Fee $43.75 Public Safety Impact Fee-Admin $26.35 Public Safety Impact Fee-Police $254.00 School Impact Fee $8,328.00 SIF 1 percent Fee $83.28 Transportation Impact Fee $3,595.68 Transportation Impact Fee-City $36.32 7054 Steer Blade Drive Zephyrhills, FL 33541 SUB TOTAL $14,770.94 REMITTANCE INFORMATION TOTAL $14,770.94 City of Zephyrhills 5335 8th Street Zephyrhills, FL 33542 January 11,2021 5335 8th Street,Zephyrhills,FL 33542 Page 1 of 1 y . D Q Single Family Dwelling Plan Review Comments 1. F:RE; shall be a minimum of 8" above the road elevation and an engineered site plan. 2: Lots shall be graded to.comply with R401.3 of the V.-B.C.. 3. Corripactiori:test required.if 24".or more,of fill dirt is brought in at any one place. 4: Tie in survey required before pouring concrete: S: Driveways require.a R.O.W.use permit: All 4 sides ofdrivewaythru the sidewalk shall have -expansion material. 6: All setbacks shall be met. 7., All property markers shall be uncovered,andmarked at time of first inspection. 8: All A.D.A.-requirements shall be met: 9: No electric,.plumbing;iechanical, or framing shall be covered without an inspection and . „_ .. . . approval first: 10:.A11 Garages shall comply with section R302.6 of the F.B.-C. (Fire Separation). 11. P opececi by approved barrierseaM303 4 otf the F.B C where ubject.to mechanical damage unless 12.-Waterheaters.shall:comply with section P607.3 ofthe F:B.C: -11 Foundation:supports for A/C units shall.be raised at least 3" above finished_ grade. M1308.:1; 14. Return air in all bedrooms. F.B.C. M1620:4 1.5. Smoke.detectors.are to be-installed in accordance with.R313;1 of the,F.B.C. 16:All glazing reguirenients are to be in accordance with R308A of the F.B.C: 17. All means of egress are to:be in accordance with R311 of the F.B.C. 18. "Green gypsum board"shall not be used as a backer in showers or tubs.R702:4.2 F.B.C. 19. Combination-type AFCI breakers are required at-all.locations requiring an-AFCI.type breaker. _20. C:arbon monoxide alarms will be required in new construction that.uses fossil-burning heating. or appliances or an attached garage. They shall be installed in accordance with the F.B.C: .21. All plumbing,mechanical,:arid electrical_shall he separate.from unit to unit: This includes_ all underground plumbing and electric. 22. All 2016 N.E.C. Codes will be enforced. 21 Tamper-'Resistant.Receptacles in accordance with 406.11 of the 2016 N.E.0 24. In accordance with the Land Development Code,lots-.shall be sodded before final_ at least 10 feet around the structure. 25: R403.5.3Hot water-pipe insulation Insulation for hot Water pipe With a minimum thermal resistance_(R-_value) of R-3 shall be applied to the followin Piping:-/:inch (19.1 mm)and'larger in:nominal diameter. Piping.serving more than one dwelling unit. Piping I cated.outside'the conditioned space:_. Piping from the Water heater to a'distribution manifold: Piping:located under a floor slab: Buried in piping. Supply and return piping in recirculation systems other than demand recirculation systems. 25. Blower door test shall be provided before C.O: 26 A copy of the energy cacls shall be with permit at all times. 27, Copy offMalinsulatiot report shall be provided ivith permit before r1 nal 28-No fence, pool onscreen enclosure :is issued with this permit' F.F.E.=Finished Floor Elevation F.B.C- Florida Building Code Wh Edition R.O.W.-Right of Way A.D.A.-Americans with Disabilities Act. N.E.C.-National Electric.Code-(2016) • City of Zephyrhills Permit Application Fax 813-780-0021 Building Department Date Received Phone Contact for Permitting asio CCCAUC� Caw— . . . . . . . .Owner's Name r nc Owner Phone Number Owner's Address Z 7-apApA 3?- Owner Phone Number Fee Simple Titleholder Name :sn Owner Phone Number Fee Simple Titleholder Address JOB ADDRESS ho r i/I LOTO SUBDIVISION PARCELID# 0136() QB CS (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED NEW CONSTR ADD/ALT SIGN = DEMOLISH INSTALL 8 REPAIR PROPOSED USE Q SFR 0 COMM OTHER TYPE OF CONSTRUCTION BLOCK FRAME STEEL DESCRIPTION OF WORK Net,) '5-4mle Piwdm reslJ#rc_(_ a& BUILDING SIZE F_ SQ FOOTAGE HEIGHT =BUILDING VALUATION OF TOTAL CONSTRUCTION so I =ELECTRICAL Z AMP SERVICE PROGRESS ENERGY = W.R.E.C. =PLUMBING 0*% Alt C7-c�b 1 9 Ar =MECHANICAL $ s6 VALUATION OF MECHANICAL INSTALLATION =GAS ROOFING QSPECIALTY OTHER EY FINISHED FLOOR ELEVATIONS oo FLOOD ZONE AREA AYES NO . . . . . . .. . . . . . . . . . . . . ■. . . W . . . . . . . BUILDER COMPANY V\L C SIGNATURE REGISTERED Y/ N FEt CURREh L]LLN_J Address 12 OIf License# Fc-,—B E o ELECTRICIAN COMPANY . S+r-n CA Elerf-6 SIGNATURE REGISTERED Y/ N ' FEE—CORREN I Y_/N Address 13400 'S+ JABS &Au License# I Ec S 0 b3-�- '3_ PlumhPLUMBER > COMPANY - lnr4 6 SIGNATURE ,f/-, REGISTERED Y/ N 'FEE CURKtr, 1 Y/N Address .6, 73w IWA3 I License# C_F C 69141- MECHANICAL COMPANY A-IV, SIGNATURE E REGISTERED FEECURREN Address 0 han lvr & esA License# �cc,33 1 OTHER COMPANY G. SIGNATURE REGISTERED Y/ N FEE CURREN L_Z_LN Address Nia F CA f-i dw '3�(05---s License# la:]S 252 3 3 RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Slit Fence installed, Sanitary Facilities&I dumpster;Site Work Permit for subdivisions/large projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction. Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans W/Silt Fence installed, Sanitary Facilities&I dumoster.Site Work Permit for all new projects.All commercial requirements must'meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. ""PROPERTY SURVEY required for all NEW construction. Directions:- - - - --- - - - - - - - - - - - Fill out application completely. Owner&Contractor sign back of application,notarized If over$2500,a Notice of Commencement is required. (A/C upgrades over$7500) Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footag6) Driveways-Not over Counter if on public roadways..needs ROW NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject\o"daed reatrictions" . which may be more restrictive than County regulations. The undersigned ouaumearemponmibUityforoomp|ionoevvdhany applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired anontroctor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as.required by law, both the owner and contractor may be cited for a misdemeanor violation under state |evv. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing.Section at.727-847- 8009, Fu[tharnnora, if the owner has hired a contractor or coDtreotors, he is advised to have thb contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign an the contractor, that may bean indication that heie notpropedy]imanoed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION (KOPACTIUTILIT\ES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and,Recourse Recovery Fees may apply to the construction of new buUdings, change of use in existing bui|dings, or expansion of existing buildings, as specified in Pasco County Ordinance nunnber8Q'O7 and 90-07. as amended. The undersigned also underetanda, that such fees, as may be due, will be identified et the time of permitting. It is further understood that Transportation Impact Feea'and Resource Recovery Fees must be paid prior to receiving o "certificate of occupancy" or final power na\aase. If the project does not involve a certificate of occupancy or final power.release, the fees must be paid prior to permit issuance. Furthermore, if P000n County Water/Sewer Impact fees are due,they must;be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW (Chapter 713. Florida Statutes, aaamneoded): |f valuation cf work io $2.5OO.00or more, | certify that |, the applicant, have been provided with o copy of the "Florida Construction Lien Law—Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the"owner", | certify that | have obtained a copy of the above described document and promise in good faith to deliver itto the"ovvnn[~prior tocommencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: | certify that all the information in this application is accurate and that all work will be done in compliance with all applicable }suwo regulating condTuciion, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. | certify that no work or installation has commenced prior to issuance of permit and that all work will be performed to meet standards of all |ovvo regulating construction, County and City codes, zoning regulations, and land development regulations iD the jurisdiction. \ also certify that | understand that the regulations of other government agencies may apply to the intended vvorh, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: - Department ofEnvironmental Protection-Cypress Bayheade' Wetland Areas and Environmentally Sensitive Lands,VVohac8WaotevvetarTreatmoOt. - Southwest Florida Water Management District-Wells', Cypress Bayheadu, Wetland Areas, Altering Watercourses. ' - Army Corps ofEngineers+Ge8vvoUs, Docks, Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, VVnatevvoter Treatment, Septic Tanks. - UG Environmental Protection Agency-Asbestos abatement. - Federal Aviation Autho[\ty-Runvveya. ' | understand that the following restrictions-apply tothe use of fill: - Use offill is not allowed in Flood Zone"\y' unless expressly permitted. - \f the fill rnatade| is to be used in Flood Zone 'N'. it is understood that a drainage plan addressing a 99co0paneating vol.ume" wiU be submitted at time of permitting vvh\uh is prepared by o professional engineer licensed by the State of Florida. - If the fill,material is to be used in Flood Zone "A" in connection with a permitted building using stern vve\| construction, | certify that fill will be used only to fill the area within the stem wall. - If fill material is to be used in any area, ( certify that use of such #U will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent prDpertios, the'owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill, an engineered drainage plan ierequired. |f \ amthe AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to oonnrOeOoing construction. l understand that o separate permit may be required for electrical work, p|Umbing, signs, vvo|\s, poo|s, air conditioning, goo, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the vvod< authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six(6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninaty (QO) days and will demonstrate justifiable cause for the extension. If work ceases for ninety(90) consecutive days, the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR —PROPERTY.—IF—YOU NTE0��0-OBGA-IN-FlNAN{%]WG�-00NSULT — WITH-Y-OURLENDER-ORAN-ATTORN5Y-t�tFORE RECORDING YOUR NOTICE OF COMMENCEMENT. OWNER OR AGENT CONTRACTOR Subscribed and sworn to(or affirr��d)beforgm�this Subscribed and sworn to(or affirmed)before me this Who is/are p or has/have prodtZed Who islare personally knov�n to me or has/have produced as identification. as identification. Notary Public Notary Public Commission No. Commission No. e FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Camden 2795 Elev F,.,cw"'Multi Gen Builder Name: 11 Horton Street: S 1( ��ua,��t/ Permit Office: (;(' % r fV City,State,Zip: ephyrhills,FL, -6 ( Permit Number: /4c Owner: 7 ®. Jurisdiction: (0/1&ot> Design Location: FL,Tampa I 3 County: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(2331.8 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1956.90 ft2 b.Frame-Wood,Adjacent R=13.0 374.89 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 4 d.N/A R= ft2 10.Ceiling Types (3024.0 sqft.) Insulation Area 5. Is this a worst case? No a.Under Attic(Vented) R=30.0 2836.00 ft2 6. Conditioned floor area above grade(ft2) 2836 b.Knee Wall(Vented) R=19.0 188.00 ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 11. Ducts R ft2 7. Windows(330.0 sqft.) Description Area a.Sup:Attic,Ret:Attic,AH:Main 6 529 a. U-Factor: Dbl,U=0.34 258.00 ft2 SHGC: SHGC=0.31 b. U-Factor: Dbl,U=0.55 72.00 ft2 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.34 a.Central Unit 41.5 SEER:15.00 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 42.0 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 4.214 ft. Area Weighted Average SHGC: 0.317 14.Hot water systems 8. Floor Types (2836.0 sqft.) Insulation Area a.Electric Cap:50 gallons EF:0.950 a.Slab-On-Grade Edge Insulation R=0.0 2836.00 ft2 b. Conservation features b.N/A R= ft2 None c.N/A R= ft2 15.Credits Pstat Glass/Floor Area: 0.116 Total Proposed Modified Loads: 84.99 PASS Total Baseline Loads: 87.48 I hereby certify that the plans and specifications covered by Review of the plans and EVE ST�g�, this calculation are in compliance with the Florida Energy specifications covered by this ti�o Apt Code. calculation indicates compliance with the Florida Energy Code. PREPARED BY: ��11a Before construction is completed r '' DATE: 11-20-20 this building will be inspected for compliance with Section 553.908 I hereby certify that this building, as desi ned,is in compliance Florida Statutes. with the Florida Energy Code. �. COI)yVE OWNER/AGENT: � BUILDING OFF'CIAL: DATE: DATE: ..ddAlt .14 - Compliance requires certification by the air handler unit manufacturer that the air handier enc osure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier.and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380,is not greater than 0.060 Qn for whole house. 11/20/2020 2:39 PM EnergyGauge®USA 6.0.02(Rev.1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 1 of 4 FORM R405-2017 FLORIDA ENERGY EFFICIENCY,CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Camden 2795 Elevv F lwMulti Gen Builder Name: DR Horton . Street: -1-osl - t0 °ti-�t� p l Permit Office: City,State,Zip: Zephyrhills,FL, � Permit Number: Owner: Jurisdiction: Design Location: FL,Tamps �3 County: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(2331.8 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1956.90 ftz b.Frame-Wood,Adjacent R=13.0 374.89 ft 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 4 d.N/A R= ft2 5. Is this a worst case? No 10.Ceiling Types (3024.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 2836.00 ftz 6. Conditioned floor area above grade(ft2) 2836 b.Knee Wall(Vented) R=19.0 188.00 ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 11.Ducts R ft2 7. Windows(330.0 sqft.) Description Area a.Sup:Attic,Ret:Attic,AH:Main 6 529 a. U-Factor: Dbl,U=0.34 258.00 ft2 SHGC: SHGC=0.31 b. U-Factor: Dbl,U=0.55 72.00 ft2 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.34 a.Central Unit 41.5 SEER:15.00 c. U-Factor: N/A ft2 -SHGC: 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 42.0 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 4.214 ft. Area Weighted Average SHGC: 0.317 14.Hot water systems a.Electric Cap:50 gallons 8. Floor Types (2836.0 sqft.) Insulation Area EF:0.950 a.Slab-On-Grade Edge Insulation R=0.0 2836.00 ft2 b. Conservation features b.N/A R= ft2 None c.N/A R= ft2 15.Credits Pstat Glass/Floor Area: 0.116 Total Proposed Modified Loads: 84.99 PASS Total Baseline Loads: 87.48 I hereby certify that the plans and specifications covered by Review of the plans and this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance �ijiri, '' _`a���.�` ✓-� with the Florida Energy Code. rrrr� % := ,; " �� �4 PREPARED BY: Before construction is completed DATE: " '�-200-20 this building will be inspected for compliance with Section 553.908 I hereby certify that this building, as desi ned,is in compliance Florida Statutes. with the Florida Energy Code. OWNER/AGENT: - BUILDING dMCI DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). - Compliance with a proposed duct leakage On requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380,is not greater than 0.060 On for whole house. 11/20/2020 2:39 PM EnergyGauge e0 USA 6.0.02(Rev.1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 1 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: Camden 2795 Elev F w Multi Bedrooms: 4 Address Type: Lot Information Building Type: User Conditioned Area: 2836 Lot# 13/13 Owner Name: Total Stories: 1 Block/Subdivision: Silverado #of Units: I Worst Case: No PlatBook: Builder Name: DR Horton Rotate Angle: 315 Street: Permit Office: Cross Ventilation: County: Pasco Jurisdiction: Whole House Fan: City,State,Zip: Zephyrhills, Family Type: Single-family FL, New/Existing: New(From Plans) Comment: Garage L Face NW CLIMATE Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Tampa FL—TAMPA—INTERNATI 39 91 70 75 645.5 54 Medium BLOCKS Number Name Area Volume 1 Blockl 2836 26374.8 SPACES " Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 Main 2836 26374.8 Yes 5 4 1 Yes Yes Yes FLOORS y # Floor Type Space Perimeter R-Value Area Tile Wood Carpet I Slab-On-Grade Edge Insulatio Main 248 ft 0 2836 ft2 ---- 0.5 0 0.5 ROOF Roof Gable Roof Red Solar SA EmItt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 3072 ft2 0 ft2 Dark Y 0.92 No 0.9 No 0 22.6 ATTIC V # Type Ventilation Vent Ratio(1 in) Area FIBS IRCC 1 Full attic Vented 300 2836 ft2 Y N CEILING Ceiling Type Space R-Value Ins Type Area Framing Frac, Truss Type .1 Under Attic(Vented) Main 30 Blown 2836 ft2 0.11 Wood 2 Knee Wall(Vented) Main 19 Blown 188 ft2 0.11 Wood 11/20/2020 2:39 PM EnergyGauge@ USA 6.0.02(Rev.1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 2 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS g- nrnt F Adjacent Space Cavity Width Height Sheathing Framing Solar Below 10 Wall-Type- R-V;1I1 -i IP Et In Et In Aron P-1/alue Fraction Abso I N=>NW Exterior Concrete Block-Int Insul Main 4.0999 20 4 9 4 189.8 ft2 0 0.6 0 2 E=>NE Exterior Concrete Block-Int Insul Main 4.0999 60 8 9 4 566.2 ft2 0 0.6 0 3 S=>SE Exterior Concrete Block-Int Insul Main 4.0999 50 0 9 4 466.7 ft2 0 0.6 0 4 W=>SW Exterior Concrete Block-Int Insul Main 4.0999 74 0 9 4 690.7 ft2 0 0.6 0 5 N=>NW Garage Frame-Wood Main 13 27 0 9 4 252.0 ft2 0.23 0.01 0 6 W=>SW Garage Frame-Wood Main 13 2 0 9 4 18.7 ft2 0.23 0.01 0 7 E=>NE Garage Frame-Wood Main 13 11 2 9 4 104.2 ft2 0.23 0.01 0 8 NE=>N Exterior Concrete Block-Int Insul Main 4.0999 4 8 9 4 43.6 ft2 0 0.600000 0 DOORS V # Omt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 N=>NW Insulated Main None .4 3 8 24 ft2 2 N=>NW Wood Main None .46 2 8 8 21.3 112 3 NE=>N Insulated Main None .4 3 8 24 ft2 WINDOWS Orientation shown is the entered orientation(=>)changed to As Built(rotated 315 degrees). Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening I N=>NW I Vinyl Low-E Double Yes 0.34 0.31 N 30.0 ft2 1 It 0 in 0ft11 in None Exterior 5 2 E=>NE 2 Vinyl Low-E Double Yes 0.34 0.31 N 45.0 ft2 1 It 0 in 0 ft 11 in None Exterior 5 3 E=>NE 2 Vinyl Low-E Double Yes 0.34 0.31 N 18.0 ft2 I ft 0 in 0 ft 11 in None Exterior 5 4 S=>SE 3 Vinyl Low-E Double Yes 0.34 0.31 N 45.0 ft2 1 ft 0 in 0 ft 10 in None Exterior 5 5 S=>SE 3 Vinyl Low-E Double Yes 0.34 0.31 N 22.5 ft2 I ft 0 In 0 ft 10 in None Exterior 5 6 S=>SE 3 Metal Low-E Double Yes 0.55 0.34 N 72.0 ft2 10 It 0 in 0 ft 2 in None Exterior 5 7 W=>SW 4 Vinyl Low-E Double Yes 0.34 0.31 N 22.5 ft2 19 ft 4 in 0 It 2 in None Exterior 5 8 W=>SW 4 Vinyl Low-E Double Yes 0.34 0.31 N 75.0 ft2 1 ft 0 in oft 11 in None Exterior 5 GARAGE V # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 619.038 ft2 619.038 ft2 62.2 It 9.3 ft 0 INFILTRATION # Scope Method SLA CFM 50 ELA EqLA ACH ACH 50 1 Wholehouse Proposed ACH(50) 000414 3077.1 168.93 317.69 .1609 7 '11/20/2020 2:39 PM EnergyGauge@ USA 6.0.02(Rev.1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 3 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT HEATING SYSTEM V - # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ None Singl HSPF:8.5 42 kBtu/hr 1 sys#1 COOLING SYSTEM V # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ None Singl SEER:15 41.5 kBtu/hr 1245 cfm 0,75 1 sys#1 HOT WATER SYSTEM V # System Type SubType Location EF Cap Use SetPnt Conservation I Electric None Garage 0.95 50 gal 70 gal 120 deg None SOLAR HOT WATER SYSTEM VFSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ft2 DUCTS ----Supply---- ----Return---- Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool I Attic 6 529 ft2 Attic 99 ft2 Proposed Qn Main ---cfm 170.2 cfm 0.06 0.60 1 1 TEMPERATURES Programable Thermostat:Y Gelling Fans: I Cooling Jan Feb Mar Apr May Jun Jul Auep Oct Nov Dec He, Jan Feb M Apr May Jun Jul Aug9 Sep Oct Nov Dec Vel Jan Feb M Apr May Ju n Jul Aug X Sep Oct Nov II Dec ThermostatSchedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 so PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default lbs/sq.ft. 0 ft2 Oft 0.3 Main 11/20/2020*2:39 PM EnergyGauge@ USA 6.0.02(Rev.1)-FlaRes2017 FBG 6th Edition(2017) Compliant Software Page 4 of 4 t 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 97 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New(From Plans) 12. Ducts, location &insulation level a)Supply ducts R 6.0 2.Single-family or multiple-family 2. Single-family b) Return ducts R 6.0 c)AHU location Main 3.No.of units(if multiple-family) 3. 1 4.Number of bedrooms 4. 4 13.Cooling system: Capacity 41.5 a)Split system SEER 5. Is this a worst case?(yes/no) 5. No b)Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area(sq.ft.) 6. 2836 d) Room unit/PTAC EER e)Other 15.0 7.Windows,type and area a) U-factor:(weighted average) 7a. 0.386 b) Solar Heat Gain Coefficient(SHGC) 7b. 0.317 14. Heating system: Capacity 42.0 c)Area 7c. 330.0 a)Split system heat pump HSPF b)Single package heat pump HSPF 8.Skylights` c) Electric resistance COP a) U-f actor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b)Solar Heat Gain Coefficient(SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 8.50 9. Floor type,insulation level: a)Slab-on-grade(R-value) 9a. 0.0 b)Wood,raised(R-value) 9b. 15.Water heating system c)Concrete,raised(R-value) 9c. a) Electric resistance EF 0.95 b) Gas fired,natural gas EF 10.Wall type and insulation: c)Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1.Wood frame(insulation R-value) 10A1. e) Dedicated heat pump with tank EF 2. Masonry(Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec% B.Adjacent: g) Other 1.Wood frame(Insulation R-value) 10131. 13.0 2.Masonry(insulation R-value) 10132. 16.HVAC credits claimed(Performance Method) 11.Ceiling type and insulation level a) Ceiling fans a) Under attic 11 a. 30.0 b)Cross ventilation No b)Single assembly 11 b. c)Whole house fan No c) Knee walls/skylight walls 11 c. 19.0 d) Multizone cooling credit d) Radiant barrier installed 11d. Yes e) Multizone heating credit f) Programmable thermostat Yes "Label required by Section R303.1.3 of the Florida Building Code,Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation,through the above energy saving features which will be installed(or exceeded) in this home before final inspection.Otherwise,a new EPL display card will be completed based on installed code compliant features. Builder Signature: �� .e' Date: Address of New Home. ��� /��� Y' City/FL Zip: Zephyrhills FL 11/20/2020 2:39:39 PM EnergyGauge@ USA 6.0.04(Rev. 1)-FlaRes2017 FBC 6th Edition(2017)Compliant Software Page 1 of 1 Florida Building Code, Energy Conservation, 6th Edition (2017) Mandato Requirements for Residential Performance, Prescriptive and ERI Methods ADDRESS: Permit Number: Zephyrhills,FL, MANDATORY REQUIREMENTS See individual code sections for full details. V/ SECTION R401 GENERAL FjR401.3 Energy Performance Level(EPL)display card(Mandatory). The building official shall require that an energy performance level(EPL) display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy.Florida law (Section 553.9085,Florida Statutes)requires the EPL display card to be included as an addendum to each sales contract for both presold and nonpresold residential buildings.The EPL display card contains information indicating the energy performance level and efficiencies of components installed in a dwelling unit.The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans and specifications submitted to demonstrate code compliance for the building.A copy of the EPL display card can be found in Appendix RD. R402.4 Air leakage(Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of Sections R402.4.1 through R402.4.5. Exception: Dwelling units of R-2 Occupancies and multiple attached single family dwellings shall be permitted to comply with Section C402.5. R402.4.1 Building thermal enveloW building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2. The sealing methods between dissimilar materials shall allow for differential expansion and contraction. R402.4.1.1 Installation.The components-of the building-thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance with the manufacturer's instructions and the criteria listed in Table R402.4.1.1,as applicable to the method of construction.Where required by the code official,an approved third party shall inspect all components and verify compliance. R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate not exceeding seven air changes per hour in Climate Zones 1 and 2,and three air changes per hour in Climate Zones 3 through 8.Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g. (50 pascals).Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7),Florida Statutes,or individuals licensed as set forth in Section 489.105(3)(f),(g)or(i)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. Exception: Testing is not required for additions,alterations,renovations,or repairs,of the building thermal envelope of existing buildings in which the new construction is less than 85 percent of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures. 2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures. 3.Interior doors,if installed at the time of the test,shall be open. 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.Heating and cooling systems,if installed at the time of the test,shall be turned off. 6.Supply and return registers,if installed at the time of the test,shall be fully open. R402.4.2 Fireplaces. New wood-burning fireplaces shall have tight-fitting flue dampers or doors,and outdoor combustion air.Where using tight-fitting doors on factory-built fireplaces listed and labeled in accordance with UL 127,the doors shall be tested and listed for the fireplace.Where using tight-fitting doors on masonry fireplaces,the doors shall be listed and labeled in accordance with UL 907. R402.4.3 Fenestration air Ieakage.Windows,skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm per square foot(1.5 Us/m2),and swinging doors no more than 0.5 cfm per square toot(2.6 Us/m2),when tested according to NFRC 400 or AAMA/WDMA/CSA 101/I.S.2/A440 by an accredited,independent laboratory and listed and labeled by the manufacturer. Exception: Site-built windows,skylights and doors. 11/20/2020 2:39 PM EnergyGaugeO USA 6.0.02(Rev. 1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 1 of 5 MANDATORY REQUIREMENTS - (Continued) R402.4.4 Rooms containing fuel-burning appliances. In Climate Zones 3 through 8,where open combustion air ducts provide combustion air to open combustion fuel burning appliances,the appliances and combustion air opening shall be located outside the building thermal envelope or enclosed in a room,isolated from inside the thermal envelope.Such rooms shall be sealed and insulated in accordance with the envelope requirements of Table R402.1.2,where the walls,floors and ceilings shall meet not less than the basement wall R-value requirement.The door into the room shall be fully gasketed and any water lines and ducts in the room insulated in accordance with Section R403.The combustion air duct shall be insulated where it passes through conditioned space to a minimum of R-8. Exceptions: 1. Direct vent appliances with both intake and exhaust pipes installed continuous to the outside. 2. Fireplaces and stoves complying with Section R402.4.2 and Section R1006 of the Florida Building Code,Residential. R402.4.5 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage between conditioned and unconditioned spaces.All recessed luminaires shall be IC-rated and labeled as having an air leakage rate not more than 2.0 cfm(0.944 Us)when tested in accordance with ASTM E283 at a 1.57 psf(75 Pa)pressure differential.All recessed luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering. R403.1 Controls. SECTION R403 SYSTEMS R403.1.1 Thermostat provision(Mandatory). At least one thermostat shall be provided for each separate heating and cooling system. R4011.3 Heat pump supplementary heat(Mandatory). Heat pumps having supplementary electric-resistance heat shall have controls that,except during defrost,prevent supplemental heat operation when the heat pump compressor can meet the heating load. R403.3.2 Sealing(Mandatory) All ducts,air handlers,filter boxes and building cavities that form the primary air containment passageways for air distribution systems shall be considered ducts or plenum chambers,shall be constructed and sealed in accordance with Section C403.2.9.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria below. Duct tightness shall be verified by testing in accordance with ANSI/RESNET/ICC 380 by either individuals as defined in Section 553.993(5)or (7),Florida Statutes,or individuals licensed as set forth in Section 489.105(3)(f),(g)or(i),Florida Statutes,to be"substantially leak free"in accordance with Section R403.3.3. R403.3.2.1 Sealed air handler. Air handlers shall have a manufacturer's designation for an air leakage of no more than 2 percent of the design airflow rate when tested in accordance with ASH RAE 193. R403.3.3 Duct testing(Mandatory). Ducts shall be pressure tested to determine air leakage by one of the following methods: 1, Rough-in test:Total leakage shall be measured with a pressure differential of 0.1 inch w.g.(25 Pa)across the system,including the manufacturer's air handler enclosure if installed at the time of the test.All registers shall be taped or otherwise sealed during the test. 2. Postconstruction test:Total leakage shall be measured with a pressure differential of 0.1 inch w.g.(25 Pa)across the entire system,including the manufacturer's air handler enclosure.Registers shall be taped or otherwise sealed during the test. Exceptions: 1. A duct air leakage test shall not be required where the ducts and air handlers are located entirely within the building thermal envelope. 2. Duct testing is not mandatory for buildings complying by Section 405 of this code. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. ❑R403.3.5 Building cavities(Mandatory). Building framing cavities shall not be used as ducts or plenums. R403.4 Mechanical system piping insulation(Mandatory). Mechanical system piping capable of carrying fluids above 105°F(41°C) or below 55°F(13°C)shall be insulated to a minimum of R-3. R403.4.1 Protection of piping insulation. Piping insulation exposed to weather shall be protected from damage,including that FJ caused by sunlight,moisture,equipment maintenance and wind,and shall provide shielding from solar radiation that can cause degradation of the material.Adhesive tape shall not be permitted. Fi R403.5.1 Heated water circulation and temperature maintenance systems(Mandatory). Heated water circulation systems shall be in accordance with Section R403.5.1.1.Heat trace temperature maintenance systems shall be in accordance with Section R403.5.1.2. Automatic controls,temperature sensors and pumps shall be accessible.Manual controls shall be readily accessible. R403.5.1.1 Circulation systems. Heated water circulation systems shall be provided with a circulation pump.The system return Qpipe shall be a dedicated return pipe or a cold water supply pipe.Gravity and thermosiphon circulation systems shall be prohibited. Controls for circulating hot water system pumps shall start the pump based on the identification of a demand for hot water within the occupancy.The controls shall automatically turn off the pump when the water in the circulation loop is at the desired temperature and when there is no demand for hot water. ❑ R403.5.1.2 Heat trace systems. Electric heat trace systems shall comply with IEEE 515.1 or UL 515.Controls for such systems shall automatically adjust the energy input to the heat tracing to maintain the desired water temperature in the piping in accordance with the times when heated water is used in the occupancy. 11/20/2020 2:39 PM EnergyGauge@ USA 6.0.02(Rev. 1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 2 of 5 MANDATORY REQUIREMENTS - (Continued) o R403.5.5 Heat traps(Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have heat traps installed on both the inlets and outlets.External heat traps shall consist of either a commercially available heat trap or a downward and upward bend of at least 3 1/2 inches(89 mm)in the hot water distribution line and cold water line located as close as possible to the storage tank. R403.5.6 Water heater efficiencies(Mandatory). . R403.5.6.1.1 Automatic controls. Service water-heating systems shall be equipped with automatic temperature controls capable of adjustment from the lowest to the highest acceptable temperature settings for the intended use.The minimum temperature setting range shall be from 1001F to 140°F(38°C to 60°C). R403.5.6.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to electric service systems to be turned off.A separate valve shall be provided to permit the energy supplied to the main burner(s)of combustion types of service water-heating systems to be turned off. EJ R403.5.6.2 Water-heating equipment. Water-heating equipment installed in residential units shall meet the minimum efficiencies of Table C404.2 in Chapter 4 of the Florida Building Code,Energy Conservation,Commercial Provisions,for the type of equipment installed. Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water-heating category.Solar water heaters shall meet the criteria of Section R403.5.6.2.1. EJ R403.5.6.2.1 Solar water-heating systems. Solar systems for domestic hot water production are rated by the annual solar energy factor of the system.The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of Certified Solar Systems.Solar collectors shall be tested in accordance with ISO Standard 9806,Test Methods for Solar Collectors, and SRCC Standard TM-1,Solar Domestic Hot Water System and Component Test Protocol.Collectors in installed solar water-heating systems should meet the following criteria: 1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal;and 2. Be installed at an orientation within 45 degrees of true south. R403.6 Mechanical ventilation(Mandatory). The building shall be provided with ventilation that meets the requirements of the Florida Building Code,Residential,or Florida Building Code,Mechanical,as applicable,or with other approved means of ventilation including:Natural,Infiltration or Mechanical means.Outdoor air intakes and exhausts shall have automatic or gravity dampers that . close when the ventilation system is not operating. ❑ R403.6.1 Whole-house mechanical ventilation system fan efficacy. When installed to function as a whole-house mechanical ventilation system,fans shall meet the efficacy requirements of Table R403.6.1. Exception: Where whole-house mechanical ventilation fans are integral to tested and listed HVAC equipment,they shall be powered by an electronically commutated motor. R403.6.2 Ventilation air. Residential buildings designed to be operated at a positive indoor pressure or for mechanical ventilation shall meet the following criteria: 1. The design air change per hour minimums for residential buildings in ASHRAE 62.2,Ventilation for Acceptable Indoor Air Quality,shall be the maximum rates allowed for residential applications. 2. No ventilation or air-conditioning system make-up air shall be provided to conditioned space from attics, crawlspaces,attached enclosed garages or outdoor spaces adjacent to swimming pools or spas. 3. If ventilation air is drawn from enclosed space(s),then the walls of the space(s)from which air is drawn shall be insulated to a minimum of R-11 and the ceiling shall be insulated to a minimum of R-19,space permitting,or R-10 otherwise. R403.7 Heating and cooling equipment(Mandatory). ❑ R403.7.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies, based on building loads for the directional orientation of the building.The manufacturer and model number of the outdoor and indoor units(if split system)shall be submitted along with the sensible and total cooling capacities at the design conditions described in Section R302.1.This Code does not allow designer safety factors,provisions for future expansion or other factors that affect equipment sizing.System sizing calculations shall not include loads created by local intermittent mechanical ventilation such as standard kitchen and bathroom exhaust systems.New or replacement heating and cooling equipment shall have an efficiency rating equal to or greater than the minimum required by federal law for the geographic location where the equipment is installed. TABLE R403.6.1 WHOLE-HOUSE MECHANICAL VENTILATION SYSTEM FAN EFFICACY FAN LOCATION AIRFLOW RATE MINIMUM MINIMUM EFFICACY a AIRFLOW RATE MAXIMU (CFM) (CFM/WATT) (CFM) Range hoods Any 2.8 cfm/watt Any In-line fan Any 2.8 cfm/watt Any Bathroom,utility room 10 1.4 cfm/watt <90 Bathroom,utility room 90 2.8 cfm/watt Any For S1:1 cfm=28.3 L/min. a. When tested in accordance with HVI Standard 916 11/20/2020 2:39 PM' EnergyGaugeO USA 6.0.02(Rev. 1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 3 of 5 MANDATORY REQUIREMENTS - (Continued) ❑ R403.7.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less than the calculated total load but not more than 1.15 times greater than the total load calculated according to the procedure selected in Section 403.7,or the closest available size provided by the manufacturer's product lines.The corresponding latent capacity of the equipment shall not be less than the calculated latent load. The published value for AHRI total capacity is a nominal,rating-test value and shall not be used for equipment sizing.Manufacturer's expanded performance data shall be used to select cooling-only equipment.This selection shall be based on the outdoor design dry-bulb temperature for the load calculation(or entering water temperature for water-source equipment),the blower CFM provided by the expanded performance data,the design value for entering wet-bulb temperature and the design value for entering dry-bulb temperature. Design values for entering wet-bulb and dry-bulb temperatures shall be for the indoor dry bulb and relative humidity used for the load calculation and shall be adjusted for return side gains if the return duct(s)is installed in an unconditioned space. Exceptions: 1. Attached single-and multiple-family residential equipment sizing may be selected so that its cooling capacity is less than the calculated total sensible load but not less than 80 percent of that load. 2. When signed and sealed by a Florida-registered engineer,in attached single-and multiple-family units,the capacity of equipment may be sized in accordance with good design practice. R403.7.1.2 Heating equipment capacity. ❑ R403.7.1.2.1 Heat pumps. Heat pump sizing shall be based on the cooling requirements as calculated according to Section R403.7.1.1,and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load even if the design heating load is 1.15 times greater than the design cooling load. ❑ R403.7.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design requirements calculated according to the procedure selected in Section R403.7.1. ❑ R403.7.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners shall not be less than the design load calculated in accordance with Section R403.7.1. ❑ R403.7.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an intermittent basis,such as anticipated additional loads caused by major entertainment events,shall have equipment sized or controlled to prevent continuous space cooling or heating within that space by one or more of the following options: 1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas. 2. A variable capacity system sized for optimum performance during base load periods is utilized. R403.8 Systems serving multiple dwelling units(Mandatory). Systems serving multiple dwelling units shall comply with Sections ❑ C403 and C404 of the IECC—Commercial Provisions in lieu of Section R403. ❑ R403.9 Snow melt and ice system controls(Mandatory) Snow-and ice-melting systems,supplied through energy service to the building, shall include automatic controls capable of shutting off the system when the pavement temperature is above 50°F(10°C),and no precipitation is failing and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40oF(4.8°C). ❑ R403.10 Pools and permanent spa energy consumption(Mandatory). The energy consumption of pools and permanent spas shall be in accordance with Sections R403.10.1 through R403.10.5. ❑ R403.10.1 Heaters. The electric power to heaters shall be controlled by a readily accessible on-off switch that is an integral part of the heater mounted on the exterior of the heater,or external to and within 3 feet(914 mm)of the heater.Operation of such switch shall not change the setting of the heater thermostat.Such switches shall be in addition to a circuit breaker for the power to the heater.Gas-fired heaters shall not be equipped with continuously burning ignition pilots. ❑ R403.10.2 Time switches. Time switches or other control methods that can automatically turn off and on according to a preset schedule shall be installed for heaters and pump motors:Heaters and pump motors that have built-in time switches shall be in compliance with this section. Exceptions: 1. Where public health standards require 24-hour pump operation. 2. Pumps that operate solar-and waste-heat-recovery pool heating systems. 3. Where pumps are powered exclusively from on-site renewable generation. R403.10.3 Covers. Outdoor heated swimming pools and outdoor permanent spas shall be equipped with a vapor-retardant cover on or at El the water surface or a liquid cover or other means proven to reduce heat loss. Exception: Where more than 70 percent of the energy for heating,computed over an operation season,is from site-recovered energy,such as from a heat.pump or solar energy source,covers or other vapor-retardant means shall not be required. R403.10.4 Gas-and oil-fired pool and spa heaters. All gas-and oil-fired pool and spa heaters shall have a minimum thermal ❑ efficiency of 82 percent for heaters manufactured on or after April 16,2013,when tested in accordance with ANSI Z 21.56.Pool heaters fired by natural or LP gas shall not have continuously burning pilot lights. 11/20/2020 2:39 PM EnergyGaugeO USA 6.0.02(Rev. 1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 4 of 5 R403.10.5 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance with AHRI 1160,Table 2,Standard Rating Conditions-Low Air Temperature.A test report from an independent laboratory is required to verify procedure compliance.Geothermal swimming pool heat pumps are not required to meet this standard. R403.11 Portable spas(Mandatorg)he energy consumption of electric-powered portable spas shall be controlled by the requirements of APSP-14. SECTION R404 ELECTRICAL POWER AND LIGHTING SYSTEMS R404.1 Lighting equipment(Mandatory). Not less than 75 percent of the lamps in permanently installed lighting fixtures shall be high-efficacy lamps or not less than 75 percent of the permanently installed lighting fixtures shall contain only high-efficacy lamps. Exception:Low-voltage lighting. R404.1.1 Lighting equipment(Mandatory).Fuel gas lighting systems shall not have continuously burning pilot lights. 11/20/2020 2:39 PM EnergyGaugeO USA 6.0.02(Rev.1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 5 of 5 2017- AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: Camden 2795 Elev F w Multi Gen Builder Name: DR Horton Street: Permit Office: City,State,Zip: Zephyrhills,FL, Permit Number: Y Owner: Jurisdiction: Lu Design Location: FL,Tampa COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air-permeable insulation shall The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. requirements Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit the Insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings,drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed, with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows,skylights The space between window/door iambs and framing,and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above-garage subfloor decking,or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing,or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation,insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace Shafts,penetrations Duct shafts,utility penetrations,and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit,or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spa c 3s. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls,or insulation that on installation readily conforms to available space shall Pyti-nri behind piping and wiring. Shower/tub The air barrier Installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air-sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed'to the sub-floor or drywall. Concealed When required to be sealed,concealed fire sprinklers shall only be I sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids I between fire 2 " I a.In addition,inspection of log walls shall MH�5ft'spig�O�T5o�ICC-400. 11/20/2020 2:39 PM EnergyGauge@ USA 6.0.02(Rev. 1)-FIaRes2017 FBC 6th Edition(2017) Compliant Software Page 1 of 1 Envelope Leakage Test Report (Blower Door Test) Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Permit#: Job:Iriformatjpn Builder: DR Horton Community: Lot: 13/13 Address: City: Zephyrhills State: FL Zip: -Ort r k TV T9511 Results; 'ith z:- .6- �heaka e-rate*o lnot�exc .1 TIVEIMETHOD�Thp� !�i!PfIES�cf b-1161- --- d fl' - 'If 'N'I'l-b O 6fi4jkg6§' ho iaWa,P-�4s guri-e 0-'Qz!nc'H'w]."g; Pascals)!" - 4h O'kndtb Zones I and 2:Q' 99 E-6'f f--'h-'!'M..o b P--4-fi ''--d " , . , - - gq �pqpe-,a-s a-, - - - - - - - the;selected .valuP P§-IPWn Pn. -rm,74054'2047(P&f6 An .-;R40672017!(ERI),-9ection 1�5eledl-s ififiitfdti -At - H 0 . -A on iForm -1 7-,FO&�9F-;'0 a 16(PO?f6n- h7ijriq W134 Q6-201,7,(ER 1) Z000 $0).specified —x 60 26375 Method for calculating building volume: CFM(50) Building Volume ACH(50) 0 Retrieved from architectural plans 1-1 PASS IS Code software calculated L E]When ACH(50) is less than 3, Mechanical Ventilation installation 0 Field measured and calculated must be verified by building department. R402.4.1.2 Testing.Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g.(50 Pascals) Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7),Florida Statues.or individuals licensed as set forth in Section 489.105(3)(f),(g),or(i)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to thecode official,Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,'beyond the intended weatherstripping or other infiltration control measures. 2.Dampers including exhaust,intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures. 3.Interior doors,if installed at the time of the test,shall be open. 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.Heating and cooling systems,if installed at the time of the test,shall be turned off. 6.Supply and return registers,if installed at the time of the test,shall be fully open. in .1.0-Oftip ,,y' Company Name: Phone: I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: Date of Test: Printed Name of Tester: License/Certification#: Issuing Authority: 11/20/2020 2:40:04 PM EnergyGauge@ USA 6.0.04(Rev. 1)-FlaRes2017 FBC 6th Edition(2017)Compliant Software Page 1 of 1 Duct Leakage Test Report Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Permit#: Builder: DR Horton Community: Lot: 13/13 Address: City: Zephyrhills State: FL Zip: 1 h0014 1pvpW-t _0O9' Per or nOAOMth* System I cfm25 ,0,413rb9dr1 01-V �p,.q Iy!I6dk-;f�66f'(an!T6tdl�hl System 2 cfm25 equal to 0 04 If alr handler unit is Jiristalleci: "h-"" ust g-andi ariuniflW.,it. q Me. -iji A 4_e§,.,r,-,.3,,, System 3 cfm25 th- -t"4h' Y wiffi-86c !pqpm _g, 19M -9, _5 e rpq tr pin;,go 4-"th er�unl uhv- 011 1 s� e,,,air;,a Sum of any cfm25 ' ' *--,- ," Total of all cfm25 0Po tI OrW- aft ERFMOOO:: i? Tb _h; n_,t0 ,,q-U-611fy- 19,1h�g: _, #f0at0_g a 2836 = Qn "Proposed duct e'a.1 Age 1QP dcf- ibd;9 h;Fo rm:�R4'054 Q;j7 t 40 Tote of all Total Conditioned systems Square Footage 'i r".M -M V i � 4Q4 '99Q� ly'_O��$QRC 4_Q5-2017 i toy 04*2W Y1 PIOW� PASS FAIL i Proposed Qn 0.06 - - ----------------- Duct tightness shall be verified by testing in accordance with ANSI/RESNET/lOC380 by either individuals as defined in Section 553.993(5) or(7),Florida Statutes,or individuals licensed as set forth in Section 489.105(3)(f), (g) or(i),Florida Statutes. 7' '7 F 'Y MA Company Name: Phone: I hereby verify that the above duct leakage testing results are in accordance with the Florida Building Code requirements with the selected compliance path as stated above,either the Prescriptive Method or Performance Method. Signature of Tester: Date of Test: Printed Name of Tester: License/Certification#: Issuing Authority: 1112012020 2:40:12 PM EnergyGauge@ USA 6.0.04(Rev.1)-FlaRes2017 FBC 6th Edition(2017)Compliant Software Page 1 of 1 Job: wrightsoft, Manual S Compliance Report Date: Entire House By: Progressive Air Systems, Inc Plan: Plan 2795 Camden 5907 Dasher Ct,Port Richey,FL 34668 Phone:727-847-3898 Fax:727-815-3399 License:CAG033669 For: DR Horton Lot 13 Blk 13 Silverado, Zephyrhills, FL .",Cooling 'E quipment Design Conditions Outdoor design DB: 91.2°F Sensible gain: 33992 Btuh Entering coil DB: 77.1OF Outdoor design WB: 77.1 OF Latent gain: 5252 Btuh Entering coil WB: 63.6°F Indoor design DB: 75.0°F Total gain: 39244 Btuh Indoor RH: 50% Estimated airflow: 1383 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Bryant Model: 215BNA042+FX4DN(B,F)043 Actual airflow: 1383 cfm Sensible capacity: 33904 Btuh 100%of load Latent capacity: 5871 Btuh 112%of load Total capacity: 39775 Btuh 101%of load SHR: 85% Hdatihg Equioment Design Conditions Outdoor design DB: 40.0°F Heat loss: 32348 Btuh Entering coil DB: 69.2°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Bryant Model: 215BNA042+FX4DN(B,F)043 Actual airflow: 1383 cfm Output capacity: 37812 Btuh 1170%of load Capacity balance: 33 OF Supplemental heat required: 0 Btuh Economic balance: -99 OF Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 1383 cfm Output capacity: 9.6 kW 102%of load Temp. rise: 22 OF Meets are all requirements of ACCA Manual S. .�+ wri htsoft, 2020-Nov-20 14:age I Z 9 Right-SuiteO Universal 2017 17.0.21 RSU25554 Page G—K ...tsoft Files\SF Tampa\2795 w Multi gen suite.rup Calc=MJ8 House Front faces:NW ' , . � Load Form ShortJob:^ — ��mtiom ��^n � ~~^=~ ^~~�=e By: Plan: P�n��s��omuan Progressive Air Inc 5907ousho ct,Port Richey,pLu46o Phone:727**7-389 Fax:727-815-3399 uoe",o:oxccmonoo For: DR Horton Lot 130k13 Si|veredn.2ephyrhiUo' FL Htg Cig KnN[tnatinn Outside db 40 91 Method Simplified Inside db 70 75 Construction quality Semi-tight Doe|gnT0 ("F) 30 16 Fireplaces O Daily range ' L Inside humidity(%) 50 50 Moisture difference(gr/lb) 26 54 HEATING EQUIPMENT COOLING EQUIPMENT Make Bryant Make Bryant Trade LEGACY LINE pURON HP Trade LEGACY LINE PURON HP - Model 215BNA042 Cond 215BNA042 AHR| ref Coll FX4DN(B'F)043 AHR| rof Efficiency D.GHSPF Efficiency 12.5EER. 158EER Heating input Sensible cooling 31125 8tuh Heating output 42000 BtuhC@47"F Latent cooling 10375 Btuh Temperature rise 28 OF Total cooling 41500 Btuh Actual aJrUmw 1388 ofm Actual air flow 1383 cfm Air flow factor 0.043 nfn/EDuh Air flow factor 0.041 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H20 Space thermostat Load sensible heat ratio 0.87 Capacity balance point=38"F Backup: ROOM NAME Area Htg load CIg load Htg AVF CIg AVF ,... "" =5 142 ° n bec/muldroom 188 2019 1802 80 77 UetU2 52 88 131 4 5 w|c2 38 U D 0 U multi/living 244 3206 4303 137 175 great 620 6867 7896 294 819 dining 175 1874 1712 80 70 bed8 185 1754 1585 75 64 bath3 | 38 | 736 | 326 | 31 | 13 B8vunity | 33 | D | O | O 0 Calculations approved byACCAtomeet all requirements nf Manual J0hEd. bed2 181 4606 3403 197 138 foyer 77 1487 1065 64 43 a/c 22 0 0 0 0 laundry 79 122 866 5 35 powder 41 239 176 10 7 Entire House d 2798 32348 33992 1383 1383 Other equip loads 0 0 Equip. Qa 1.00 RSM 33992 Latent cooling 5252 TOTALS 2798 32348 39244 1383 1383 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. A:L wri htsoft9 2020-Nov-20 14: ge 2 z�, 9 Right-Suite®Universal 2017 17.0.21 RSU25554 Page 2 A ...tsoft Files\SF Tampa\2795 w Multi gen suite.rup Calc=MJ8 House Front faces:NW FORM R405-2017 RESIDENTIAL ENERGY CONSERVATION CODE DOCUMENTATION CHECKLIST Florida Department of Business and Professional Regulation Simulated Performance Alternative(Performance)Method Applications for compliance with the 2017 Florida Building Code, Energy Conservation via the residential Simulated Performance Method shall include: ❑ This checklist ❑ A Form R405 report that documents that the Proposed Design complies with Section R405.3 of the Florida Energy Code. This form shall include a summary page indicating home address, e-ratio and the pass or fall status along with summary areas and types of components, whether the home was simulated as a worst-case orientation, name and version of the compliance software tool, name of individual completing the compliance report(one page)and an input summary checklist that can be used for field verification(usually four pages/may be greater). ❑ Energy Performance Level(EPL)Display Card(one page) ❑ HVAC system sizing and selection based on ACCA Manual S or per exceptions provided in Section R403.7 ❑ Mandatory Requirements(five pages) Required prior to CO for the Performance Method. ❑ Air Barrier and Insulation Inspection Component Criteria checklist(Table R402.4.1.1 - one page) ❑ A completed Envelope Leakage Test Report(usually one page) ❑ If Form R405 duct leakage type indicates anything other than "default leakage", then a completed Form R405 Duct Leakage Test Report(usually one page) 11/20/2020 2:54:07 PM EnergyGauge@)USA 6.0.04(Rev.1)-RaRes2017 FBC 6th Edition(2017)Compliant Software Page 1 of 1 1 r PLOT PLAN DESCRIPTION:(AS FURNISHED) LOT 13, BLOCK 13, SILVERADO RANCH SUBDIVISION PHASE 10A AS RECORDED IN PLAT BOOK 80, PAGE(S) 107-112, OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. Curve Table ON LOT CALCULATIONS Curve f Length Radlus Delta Chord Bening Chord LOT — 9,324 SQ. FT. C1 43.91' 330.00' 7'37'2a' N39.11'13'E 43.88' LIVING AREA = 2.836 SO. FT. GARAGE = 619 SO. FT. C2 35.88' 25.OW 81'48'10' S02W52'W 32.73' ENTRY = 65 SO. FT. C3 BZ61' 192.00' 243911" s51V5'49'E 61.98' LANAI = 193 SO. FT. MULTI—GEN = 25 SQ. FT. C4 272 SW 300.00' 52'07'49' N2557'46'E 263.84' DRIVEWAY = 671 SO. FT. C5 1 85.86' 1300.OW I 1833'03'I N43'45'09'E I 86.3W A/C PAD = 12 SO. FT. WALKWAY = 0 SQ. FT. CB 186.29'130O.OW 3534'46'1 N17'41'15'E 1 153.31' IMPERVIOUS = 47% = 4421 SO. FT. a 4~ SOD = 4,903 SQ. FT. Una Table OFF LOT CALCULATIONS LIne f Dlrodion Length RIGHT OF WAY = 3738 SQ. F7. Z DRIVE APRON = 374 SO. FT. L7 N38-46.13-W 20.46' PUBLIC S/W = 1094 SO. FT. 1" = 30' SOD = Z270 SO. FT. GRAPHIC SCALE TOTALS 0 15 30 AREA = 13,062 SO. FT. DRIVEWAY - 1.045 SO. FT. SIDEWALK - 1094 SQ. FT. SOD = 7.173 SQ. FT. 80 fit. 44 •;�;r'",<�:. ._ . • ^� �s , �, OA,c� .: 6 \ y. 110. \ 4Y \ \ \ /.0. 00, 0 � 0• Ilk. 9�90yc \ ♦\`\ \ / ,fie A,V� O PREPARED FOR: 0, 12�ss BUILDING SETBACKS. \ FRONT: 22' \ ` REAR: 13' \ SIDE: 5' (50' LOTS) 7.5' (55' & 60' WIDTH LOTS) SIDE STREET: 15' \ LEGEND: NOTES: — — — BUILDING SETBACK LINE PI POINT OF INTERSECTION PC POINT OF CURVATURE 1. ELEVATIONS SHOWN ARE PER LOT GRADING ——— CENTERLINE PT POINT OF TANGENCY PLANS PROVIDED BY THE CLIENT. ———— RIGHT OF WAY LINE RP RADIUS POINT 2 ELEVATIONS ARE BASED ON NAVD 1988 10t PRC POINT OF REVERSE CURVATURE DATUM. PROPOSED ELEVATION PCC POINT OF COMPOUND CURVATURE TYP TYPICAL PROPOSED DRAINAGE FLOW CS CONCRETE SLAB THIS PLOT PLAN IS INTENDED FOR PERMITTING PURPOSES P) PER PLAT CONCRETE CALCULATED ONLY. THIS IS NOT INTENDED FOR THE CONSTRUCTION OF C PLAT BOOK THE PROPOSED HOUSE. REFER TO HOUSE PLAN AND A/C AIR CONDITIONER PB PG5 PAGES OPTION LIST FOR CONSTRUCTION. ALL BUILDING SET BACK S/W SIDEWALK SO.FT. SQUARE FEET LINES SHOWN HEREON IS PER DATA FURNISHED BY CLIENT F.E.M.A. FEDERAL EMERGENCY MANAGEMENT AGENCY AND IS FOR INFORMATIONAL PURPOSES ONLY. F.I.R.M. FLOOD INSURANCE RATE MAP NAVD NORTH AMERICAN VERTICAL DATUM THIS IS NOT A SURVEY NGVD NATIONAL GEODETIC VERTICAL DATUM D&UE DRAINAGE&UTILITY EASEMENT THIS IS A PLOT PLAN ONLY PDE PRIVATE DRAINAGE EASEMENT PUE PUBLIC UTILITY EASEMENT FLOOD NOTE: SURVEYOR NOTES: I HAVE EXAMINED THE F.I.R.M.MAP NO. 12101CO288F, 1. THE SURVEYOR HAS NOT ABSTRACTED THE ED DAT SEPTEMBER 28.2014. AND FOUND THE SUBJECT PROPERTY LAND SHOWN HEREON FOR EASEMENTS, RIGHT APPEARS TO LIE IN ZONE-X', AREAS DETERMINED TO BE OUTSIDE THE OF WAY, RESTRICTIONS OF RECORD WHICH 0.2%ANNUAL CHANCE FLOODPLAIN. THE SURVEYOR MAKES NO MAY AFFECT THE TITLE OR USE OF THE LAND, GUARANTEES AS TO THE ABOVE INFORMATION. Pig CONTACT THE LOCAL F.E.M.A. AGENT FOR VERIFICATION. 2. NO UNDERGROUND IMPROVEMENTS HAVE BEEN BEARING BASIS: LOCATED EXCEPT AS SHOWN. BEARINGS SHOWN HEREON ARE BASED ON THE NORTHEASTERLY LINE 3. NOT VALID WITHOUT THE AUTHENTIC OF LOT 13 BLOCK 13 SONG 55538'57'E,PER PLAT. ELECTRONIC'SIGNATURE AND THE AUTHENTIC ELECTRONIC SEAL OF A FLORIDA LICENSED (FIELD DATE:) REVISED: M E fR 1 CAN SURVEYOR AND MAPPER. _ S U RV EY I N G SCALE 1' 30 FEET 4 a gc;;NeG DlgitallyslgnedbyJamesWBoleman MAPPING INC. `'' ""'` DN:rUS,st=Florlda,l=0dando, '"� �''�'` o—AMEBICAN SURVEYING&MAPPING, �'" r_sss„ APPROVED BY: '� 6 .`IN4 cn=James W Boleman, CERTIFICATION OF AUTHORIZATION NUMBER LBf6393 -\. *•�^•+x G email=jholeman@asmco porate.com FOR 3191 MAGUIRE BOULEVARD, SUITE 200 s'•` "m:•s' Date 2020.11.100e:1em3-0s0n JOB No. 200647 LOT 13.BLOCK 13 ORLANDO. FLORIDA 32803 mnouima��°�� AdobeAcmbatvealom11.0.23 PLOT PLAN 1 FIRM 0JSO THE RMB (407) 426-7979 - DRAWN BY. 1—OS-202 WWW.AMERICANSURVEYINGANDMAPPING.COM JAMES W. BOLEMAN PSM 6485 DATE PASCO COUNTY, FLORIDA Permit No. Date Permitted Builder Name/Owner-Name IJ k Control County Parcel No. 3 2—2_6 2-1/) (/a h ,3DQ Z 15-0 SubDly: Address/Location 0 Class{ficattonlType of Use S i TRANSPORTATIORIMPACTFEE . Rate: Sq.FtUnit: Exempt []Yes [] No How Determined lmpect Fee Amount Zone No. TAM SCHOOL IMPACT FEE Account (056) Single-Family Detached House Amount $ �. 2W. (057) Mobile Home -- ? (058) Other.Resldenttat dyei 23) Collection Fee Exempt . [[No How.Datermined PAR MAND`REGREAI ION FEE .� Land Account Land Credit Land Total Recreation Account Racteaon-Credit Recreatton:Tota1 Zone �� TOTAL=AMOUNT $ ' ' Exempt ❑Yes []No How.I7eteirnlned' ` LIB :FEE RAliy ` Land Account Land-Credit Land Total Facility Account;; Facility Credit. Facility Total .Exempt Yes [[�NQ How Determined Total Amount ''{.'•�?roc. . RE3 VRM FEE" ERt1 XOTAr AMOUNT Prepared By - checked By NO CERTIFICA'FE..OF OCCUPANCY,`WILL'BEISSUER;OR;FINAL:INSPECTION PERFOi�UIEd`E!N'tit,T!#Efi+DTAL.-A tbUNTS't t8TED FfAVE `BEEI!I P. dt+lp . . RECEIPTED•FOR'BY A-CEN°I'RAIaPERMITI'INO OFFICE-OF PASCOvOUNTY AatiRawledgementbelawdo@anot1mply;acceptenceof'concunence.bytslmPly,recelgt,o�acopf:oftil(efom�;Ptacing. _ ' the titiltdifip penidtow»eccsi roHee otthis easesefnent and t6�'condfi�ons•of paying focssme. DATE RECEIVED'"BY RECEIPTM. DATE BY