HomeMy WebLinkAbout20-1215 �1 City of Zephyrhills i BER
5335 Eighth Street
Zephyrhills, FL 33542 ELCMISC-001215-2020
,.y Phone: (813)780-0020 Issue Date: 01/26/2021
Fax: (813)780-0021
Permit Type: Electric Service Replacement/Misc
Prope,Lrty Number Street Address
35 25 21 0140 00900 0420 7827 Davie Ray Drive
Owner Information000Permfflaformation Contractor l. _r1mation
Name: LUIS PENA AMABLEYCEL Permit Type:Electric Service Replacement/M Contractor:TITAN SOLAR POWER FL
ANDERSON Class of Work:Add/Alter Residential INC
Address: 7827 Davie Ray Dr Building Valuation:$0.00
ZEPHYRHILLS,FL 33542 Electrical Valuation:$43,000.00
Phone: (832)385-2745 Mechanical Valuation:
Plumbing Valuation:
Total Valuation:$43,000.00
Total Fees:$382.50
Amount Paid:$382.50
Date Paid:1/26/2021 10:23:51AM
P.no i Wall Dow
escription
INSTALLATION PV SOLAR ROOF MOUNT
Application Fees
Electrical Permit Fee $255.00 Electrical Plan Review Fee $127.50
REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c)the
local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or
first reinspection,whichever is greater,for each subsequent reinspection.
Notice: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that
may be found in the public records of this county, and there may be additional permit required from other governmental
entities such as water management, state agencies or federal agencies.
"Warning to owner:Your failure to record a notice of commencement may result in your paying twice for
improvements to your property.If you intend to obtain financing,consult with your lender or an attorney
before recording your notice of commencement."
Complete Plans,Specifications add fee Must Accompany Application.All work shall be performed in
accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O.
NO OCCUPANCY BEFORE C.O.
-->,
CONTRACTOR'SIGNATURE= PE IT OFFICE
PERMIT_EXPI ESN '6 MONTHS WITHOUT APPROVED_:INSPECTION'
--CALL FOR-INSPECTION - 8 HOUR NOTICE-REQUIRED----' -
PROTECT CARD FROM WEATHER
t3i�ieov it City"oflephyrhillsPOrinitApplication Pacers- 2t
. - -,`�tJflGing oepartrseM" .; ,
Dato.Raw(ved pkhacoafnciforParm>hi (- 262$$O97?�`L-
------------
owmiaNal inu oxrterP�aeetiumhcr : :$323$52745 .. :_
7827bavleR2 pr7e 1 F
Dwnata md..s Y_- ,PhY?,? _4.3354 Ovmer,PhanaNuvwbu"r,._��y
2
Fee 5lmpta tlUe}taS Porf�mo, O fw Pden►Numbar `
FaeStmpteitUehofd4rAddtesa ..- ..�:. - - . _ ..
JOBA-noRESS' 27 Davie Ray pr-Z—e�hy-i fil(s'Ft
SUODMSION: i` -P,3meL, -35-. .--otat1-W090U-fl 2rr'."
"WORK PROPOSED ttGVlcowna� � AbWAL'r', -� "SIGN"
INSTALC:•.L,».r RE4'AI .
>PRL?Pf]SEq US!" Q .SFR... ..] .CC;JI67" [%�; _OTYt`R: : - '
TYi'+EOF,t'.ONS'iR11GTi0fii. : __13LbGiCC3--- -" �
OESCMIMONOEYtORK IaotarPVisist841ga6tiit - - ':
BUIWWGSt2E�. ^- .: -I- SOFD6TAGC - , 'H=iGHr - - -
sirsccaae';'ztc_cescsca:VC tv-%:V c+Clopt%xxv, ;cKatziccc�cre 'esxccrXexx'wrrzccn.
QoIJttAfNC+•,- S.- . - VtJ,ItA41Q150FTQTA.CO•`iSTt7UCTIQHQ,CJ- -
I;l-ECTRiCAI. S '- lW SMOGE "® PF2GCRr.SS LIVERGY -p tN fZE.c - '
., '
(�PLurttat _ s:
Cjc>rs [Q raaoFr�, `p srertwrr[� ,.orR�R `
t`t!JSFtcDFt�REtt"VATtCNS FLODUYOC1t:AR£A :- � td0:
WILDER L I COEEf+arSY
SIGNATURE- LLL YJN 2,FeeewersJ, Ytra•-
- -
,
e
-addraz y i N US3Q1 Thorwto°3ssa F1335s2`... • Ltranu YF';�Ci34t?9924 - . ._. _``` -
P•tUlASc72' GOGtEANY
•SIGIU1tTUR£ '' Moi9TCREt1 o
e�tacNtisCAa couPaNx t
StGNA7URC i ttla SleRt9 Ytt1 M_ s[�Ccf `7 YtN
a:.tl[tViSfl�
. .. . Addrew
OTFM
SIGNATURE dYUstitltE� - YJN ..- tRCir!+R[N YFN - _
i7Gdrizs-. - 4taut�e'
'.RESIDENM--At1SM(2)PM PAIY.;(2l sots at alkl?U Plats,(1)'8 crE,p ai f Rtti .R-O-Yf PMma(crnew'cxaroc�Jm
_" '.�:t�snmt,�miea(Ea)w�tfd�dcf.§sfizsiw'.iiiSitai rtaia Rczfit3amatc+:fi.±�s�uetiaa"P1mr�.Siim�w�tnr E'tanss�Sr7t F'aam lrwttliod.. - _ '
. --^S:mibry fiad�t�c s 7 OcnnF�'Ito Wgaic PI.^ttal!Wt cuoc£�4�uaw'ta(p Ptvlaets'. ," "_ -- .
_ COiInmtRdmL, A090(2)cc�si*lerrAso25uu&nPtx,41t*rQLtteS�iCtYP o b)3otzCLnergyFasm�I3 WPems�formrrJc�inaeY�rt,
_ _,:.htlglmliftltr:R(1P}ssi}�HGny��4trsilbmafr,Fdste•RequbBdo)Mite:Gs�sbroeSaTP4ns;5tarnns:�isP�nsti+QS[ttre�vccrt%c_aT,eC,
SarmltayFneYSGesaShcsnttSl�SAF'tlAlkFBtils3raCsatb[!V�Vptq)apa..ekm2tm--rtitdlFgquiSactemR�+.dttk.CS-G7t11�1FAt -
StGNPERAAdT At�tr(2jrei.,atfroyre'oraiiPtatas -: ;'..
�N'ROPcR1Y'SURV�tFeRctndturNEYdawtmtllon -
Birectlor�
Unrfsrr a Cmatuctoirs�mck ut�ptic�bi):+sasaslzed.: '
.. - It erer 325QC s}taUca ar Comas.ixcameottsraggJtad,(AfG upgxadca ovacS7�). - -- - --- .;;
, ,. .. ': 'Agrn!(axlM13 font¢Ylwy caP(�"rd'ALaf7•sry(fGrtit^t7+x�Mwau!ii�Os¢'�wa+e NiRl natetiz¢C Ii�Ctkam cHitar�UiuiSi2l ao:Te.'
.OVERYNECQUtrTERfLRLStFicHr3-'. -r�M4i#CmRV�Satrepuirad} -
.".'Etorarira#Wang{ca :', :':Sp^,1WUp(Er:7d.�sAtC ' Fenws(Prat�lSutv�'Ftsai�a} "
lkFnwunys.tlotc�n.4Caunlfritcm�bl�crcnib�^rys.oa+a6a.RCM
eta zeo uuio City of Zopftyrhills_Permit Application:Fax-0t3 raa eD2t.
� �AaxldbD>kF3rtmcm- -
NOTICE OF DEED=TRICTIONS:Tlw underrigned undcis-itdU thei lNe petmn mw/tie sib}eet to char rM ictiotirw tuh may W mtio ter diivc
umCWNyn ialrG'Is.TtiR_t1MiKsiRTC'dassintiC-.ru'�7IIn5firb:Y.fOrCl2Rlt�'.iIOL•Wlrtl why appS/�bAde@d rmIIICftta: _
UNLICENSED CONTPACTORS AND.CONTRACTOR RESPONWIr:ms,"themrerbaa t>veaaaoflu3clmwtonitacd t4 UtMrRatce wit,tlt�i. r, ,
may bu itll fired to be flGensM in acz i vice wM size rind loaaf icguta:ictfs.q tlYi,t:ori^apod F nq Gana:cd mW&cM by16 both ew ow wr i". '
cow-raciormaybeatedforami:kloineworvotsflanfirderfdptctav,llthoaenoror6,lendvdcarivst�nrouict .iha6tatti,tsotprci'>rit9mge,1•omeras.:.
awapWY for tna Intended WOOL diuy ae advi:od to orxtnct Ilia Pn=Cou*BuVding 1wpeafrco Oirrdofi=LlwMft saacbai al727147-WW.
, - f"w�r,maa,erha orsitcc rs�t�,v9armfine',�rcreanirtetarwtwis a4.ced tat�a ma uafracros{e}si*,In:��orsc�erilm•amtr3gaF3kufC of fhb
3ppIcagain foc atdch theyv%9 bC rtoUpmsibto.-H you,is tic cicr4r,3 t'pi as the cart dal.tt antra}area indiGAicnihat tie I teat property licensed and is
not entted to poml ing prfalegec in Parxd Coonty:
TRANSPORTA710N fNIFACTNTiL17iES IPRFIICT AND RESOURCE RECOVERYPCES:The undersigned understands
.th3l Tfa9sptYkTVan Impta Fees aM eecour„o fit :e'ky Fi�zs mtTy z+pply to k'to Ccrrtlrticbett of ne+v bi.�.'dfCR charg0 of rw in oads&l;au36nys,or
ezp3leannfc>i agbrdldtig~. .EporiTitdtoParmaCawityteCinancelsut Et9-07ssad> iH,os.a:sr�WFd.The wda5tgnotAisowiftltards.ttrat.
writ feeT,;>u irsy tredua,wD bo i',nn4�d a4llt tlrnc of prmdtinp.t(c#.trthertvld^_tsiwd that Tronspad�:ur+inpactfoas and Rasolnco Retrnhrp
' -Foes ineinl ba_paid Arlan fo rouKifag a'mfl�aM�oawparx�a Ordit power(b'CaSa.Ytrro pralcC di�MI trNNve o GCrlifiG.ts of cat,poncy ar fErrd
povor ailtaao,Ilea teas rrallSt bfl paid prier la.pattlS115Ui8a:re.FUIalMmarB.If Pasai Cfi,nty N'ab,rl5traer Impact fai We die,they Iiri it to p,'dtf pror
' - : ropcm�S3uetrceiridacmdamvdlnapcll,-s.GlePasooCosm:ycc'detarrcce.' . .
•COt2STRtlCTIDN CIENtArtl{Chapzer713;ftartara Statatao,as amoadudjCftvalaa%andvuri 1;52,5CD,Door. vtVaitt;gnapocart,
Aa;e 6ttat pry i�d wtth a arsyof era•ForMa Cori;lntc2on tlwn t.aw-Fintneeemc�,"s protetiiaK C�irCa-frepxad by,tho Florida Depwtmera of
�.-Apiaffluraand Con:i txAlfairs.DVie appEtant Is cofactsao oCtoftlwultito'awrior,ICwLly that l how abWhwd a copyoffhe above tic-,. Mi
- ' 'dau`mrcTat and prtiinlso et good f�m[odr.Vvcrltto.th?'Gw1^pl pdorl0 asrocnanrav+ar.',�- - .
. : 'CONTRACTOtYSfOWN:3t'SAFFIDAVfT';4catdrydrataptt�4uoi'sns+iei2ln'rtt��prir�aa�ac�craroffiidfEliaiaitai,rktvIIbed�`ai»m:ry�t:Ittav,�;rs -
ala;.prootJ4i-rs+rs nyp.Cifirij.eaasn,cnon.zGtvnA Cmd rkveFri�ancnk. IcaWnishorabymadato-avtain apenratodo e�vntandkrsiafa2was- .
faSratert'1 cvfify that.no walk or Inctall.Coo bns emtvnmacdpAar to Insaana,of a Vomit and Gu^A an avrk v ill to ptarlamw 10 i kil elnMmtAr of a!J..
Irw regttiapag ma•kuthan,Corutryarq Cay t'tJden,=TiUV putiticuio,grad land dsvdlapmettil tegitaGorts In VM patsdoU`At I woo ww Ma t
aadetc:etld V:at me ragila6ons er odor gmvmm�tt,rginralts moy apply Na me IrdarWcO work.artd mat it is riey tesparaxDfn}?to klenGPjxmal rn:'Ilats t
musttaka
i nartmcfrt of Ernfronmentsi'F'r6teciion Cypress Bayticads,Viteslarid:iSreas.and C-nvirorimentatly Scnsi iV0..
t.a?ii3a,ah'aLrMtastevrotor-Treatment__;`;•''„ :. � -
SDutMvest 'Flofida 4^later°ldanogemerit 1?is1dG YVclls,.Cypress &_yyhcads; Wetland Areas,-AlEering
+rYatartxafl#scs, - -. =;,.. ' '.':.....; .::-�.. .. � . . • --
- Army:Corps of ErigineerSSeaivapv:Dor.3�:,Naaigabte WatenvayN,�•.. '
- Department of'Hearsh:'&RthtlbTrtaGvc.:SeiviatstEnvironmentat,.Heallh Uitit-Wclls.`Wastewater Treatment,'
Septic T;inks.
US Eslvironnidntat Protect 66Agttngy=A:bostas attatement
Federal Avialron Authority Run+toys;
.. I arAcrstaoil ukd mo 61U r nraira gpp*to tIlo,rs*.9 of cat._Use of fill is not allov,ed ImEtood Zorte'W unless'ezpTessly pcimiited_;:
- It"th :matAciat:is to,lie a es1'ni F3dDd'7-, 6-A! it is`uriGeistood'thaf a drainage plah'addM:ssing a
e.fli
'cornpDnsalirlg volume'will be'.submitred at Gme;of perm 6_ng which is piepareil.by'a professional engineer,`.
ticettsEd by the Slate of Florida _: .°. -.
1f%6x fill;material is to be;t ei3.itt F16otl ions A'Ili connection v,ith a peim tei3 baadisig;using-stern Won
construction:,I aertiry that fdi'mi be`ttsed;only to f€i the aiea Within,the steritwoti:
If rill material'is-to-be:u:Ied,at..Driy-area;i,.eertity-thwt use of cutlr ftvnli-not:edvetsrity'atiect:adJacent
properties:If tise'af fig is ttriirld"to advcr�eFj atiLot.Rojacept properties.t w otivnermay"be fated:fdc v�tating
file co ldifiors'of the bulgdu>g germll lssyed under tito auaifitert permit application,for tots'tcss-shall:one{4}';
acro4Nrh are etavated by'Gp,an engineered drain je ptbn rdgti¢ed__
It t am'4ho AC NT FOR THE OWNER I promise ki good ralm to thorns the aemct*tho porrol t o ccr4udas aut faith in this tffilmll pitor to
oatair>crrrktA eoa&trurfibn:[imCaretaod mat a sc-parste pamtit may be icgiared fortfoZricul vmfK plami si,;pa,voUls,tools:air 00cid1Gea1tog.gout.ci
ourerla5 taf mninsl4> `raYy lada d of via 411co tot.A pamg lsstasa sirai be cutslnu to boa lceasn to prodded iMh ll a work cad itd as_
tovidiata;eanw;alld,s cat aside any pmi6sltns of Lhet�irkalwta,'rwraliaV issuance ofa,pdrt`rit pretcat the lliugikrg C4Wftm-
Chgen£cr ru'giisirig,a,CprroC9oli of eaars in jba;, sVrroti4a cr Yla:tliwa of any oiama.EvttY pariiilt(esaed 1SIt3p ixanitn Im711d uitic u G1a w01ir
. •.aramotiadbOichpennllKcammaarrod well ictMinoamsofpam;kbodwIca,or9imrk put horlaic'�dbytiepogi,lil;suspendedorotrarA dfora-
_'
period ofa8t(6)month3�un'4metbew.akisiomrnonoe.Anar%altsoaa-may burcgrtteilcd,in%%t&g,from_triaBWctrtitOrfkiatfcrapersadroita
=ccodninety(w)(lin andiyll tojirAC.ab6arausoWVcrxttitSlori.tfvmitwasaafofniidty(ED}carisrrutivad,7Y::ttaaJvDlsoansddrn*9,. .. - ..
7.
WARNING.TQ 0WKER:.YOUR'FAILURE TO RECORD'A NO TICE.OF.COM57ENCEMENT MAY,RESULT IN YOUR-
,' '.
PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY:tE YOU IN END 1 O'ABFAJN FINANCING,CONSULT=
Y9 vat tcEClf? FiOR tS�tt�28�tEY arm�Rh:KSt_ni_i:fz.y6uRK6 tcE.oi:.d i AmE-i cFmENL:-
F�ORIDANJRAT -
AG£NT'.: �'..i'h :„� - --�• COHTRACTOR- -
SIt SFtI'AdartdLWViBN(ardifirnF:id}hofatotria tti•L" _':. - - j-tiff"
a 7 aars.�rn��.{drain it j4enP
Y. -' ti 'rfJ{f d:'bY X��U `tCl `'.
.. :: ""Per. Y�nrixn Wrrkh diaaavraw ptod�wod�" - m p�ersrnr9yFowwn to ran at tunur mpntoll"d
_aY xFCntiGrs,Han: -
t%ORUryefrall sac - - - - -. _ ;; ..•, .;'t,41� - _�" - ':G w `'solo; �- - - - -
Ndiiry'Pth'Aad ._ tLJr:..�
. _. _ i• . tQ�� Lr�:
all mlmyrype nocder pea INafciylyp�ed prvledor pedl
tr"ORI DEE.P.ORkS1K
�•�•
# Not®ry:Public-Sthto of Florida
}= Conimissitin*GG 3102u2.-
d :lly Commission Expires--
MofCh I is 2023,..'
PROJECT DESCRIPTION
• r SYSTEM CAPACITY:11.6 KW DC/10.0 KW AC
� - NORTH
PV PANELS:(40)Q.PEAK BLK-G4.1 290W BY QCELL
OPTIMIZERS:(40)P320 BY SOLAREDGE
INVERTER:(1)SE10000H-US BY SOLAREDGE
V RACKING SYSTEM:CROSS RAIL 48XL BY EVEREST
PROJECT INFORMATION
PROJECT LATITUDE I 29.28592 MIN AMBIENT TEMP I 1 .C�
PROJECT LONGITUDE -82.177645 MAXAMBIENTTEMP 35°C
WIND EXPOSURE B
AHJ ZEPHYRHILLB
MAX WIND SPEED 137 MPH
DRAWINGS INDEX
® LOCATIONMAP / WINDZONES
J Y C-1 COVER SHEET
N.T.S. , C-2 SAFETY PLANS
1 E-1 ONE LINE RISER DIAGRAM
E-2 SAFETY LABELS
S•1 STRUCTURAL PLAN
S-2 RACKING PLAN
D-1 PV MODULES DATA SHEET
D-2 SMART MONITORING DATA SHEET
D-3 INVERTER DATA SHE
' I ET GENERAL NOTES
n 1 PER FL.STATUTE 377.705(REVISED 711/2017),I RAFAEL A.GONZALEZ
SOTO,P.E.83104 AN ENGINEER LICENSED PURSUANT TO CHAPTER
471, CERTIFY THAT THE PV ELECTRICAL SYSTEM AND ELECTRICAL
COMPONENTS ARE DESIGNED AND APPROVED USING THE
STANDARDS CONTAINED IN THE MOST RECENT VERSION OF THE
FLORIDA BUILDING CODE.
A
APPLICABLE CODES:2017 FLORIDA BUILDING CODE 6TH,ASCE 7-10
MINIMUM DESIGN LOADS FOR BUILDING AND OTHER STRUCTURES,
NEC 2014 ELECTRICAL CODE
III f
'Lt AL NIR
ND DESIGN CRITERIA AND PARAMETERS ARE FOR HIP AND
TIAL ROOFS,CONSIDERING FROM A 7°TO A MAXIMUM
REVIEW DATE (211214 MAXIMUM 6/12 PITCH ROOF IN SCHEDULE. ALL
TLAL ROOFS SHALL NOT EXCEED 30'-0"MEAN ROOF HEIGHT.
3 IRRADIANCE MAP EXISTING ELECTRICAL METER-...I CITY OF ZEPHYRHI SEALANTS SHALL CONFORM TO ASTM C920 AND ASTM 6511,
N.T.S. PV DISCONNECT---_I PLAN EXAMINER IS ESPONSIBILITY OF THE CONTRACTOR TO PILOT FILL ALL HOLES.
PV STRING INVERTER#1 -__ SHALL ENSURE ALL ROOF PENETRATIONS TO BE
FOI�CjAL,jGOVERNING
AND SEALED PER 2017 FLORIDA BUILDING CODE OR
CALGOVERNING ALL WORK SHALL COMPLY WIA1LLINf CODE.
.,_►; .,. CODES FLORIDA BUILDING C WIRING METHODS AND INSTALLATION PRACTICES SHALL
rr.•iG,v '� NFORM TO THE NATIONAL ELECTRICAL CODE(NEC)2014, LOCAL
NATIONAL ELECTRIC CODE, ' STATE CODES, AND OTHER APPLICABLE LOCAL CODES. MEANS
CITY OF ZEPHYRHIL 6HALL BE PROVIDED TO DISCONNECT ALL CURRENT CARRYING
ONDUM ALL
p.CUNG ST L ANCES OTHER CCONDUCTORS TORS OF THE PHOTOVOLTAIC
BUILDING. CONNECTORS ROTO BE
�► S1pE TORQUED PER DEVICE LISTING, OR MANUFACTURERS
RECOMMENDATIONS.NON-CURRENT CARRYING METAL PARTS SHALL
IiiI''I►/ BE CHECKED FOR PROPER GROUNDING.
•� �•�,� ������ , O l�Z ` 2/,/ REQUIRED�j ATTACHED BY ADHESIVE,OR OTHER MECHANICAL MEANS,LABELSFTHE
Z� +' ETY SIGNS AND LABELS SHALL BE PERMANENTLY
tN`�� S SHALL COMPLY WITH ARTICLE 690 VI OF THE NEC 2014 OR OTHER
APPLICABLE STATE AND LOCAL CODES.SEE LABELS AND MARKING
8x3.04 PAGE FOR MORE INFORMATION.RACKING ROOF MOUNT SYSTEM SHALL BE INSTALLED FOLLOWING
` - MANUFACTURERS INSTRUCTION SPEC'S,INCLUDING ALL GROUNDING
WEEB CLIPS,GROUND LUGS,AND RAIL SPLICE KITS FOR ELECTRICAL
CONTINUITY.
OF
® 3D RENDERING ROOF PLAN VIEW / BOS LOCATION � ` R' .•. MECDWGDTDOL IS ESIGN BASED U ARELOADSCALCULATED
USING
�Il BUILDINGS. DESIGN WIND PRESSURES ARE CALCULATED USING
ASCE 7-10 EQUATION IN FIGURES ASCE 7-10 30.4-1
N.T.S. N.T.S. ,/// ` AND 30.4-2(AB AND/67C)HAVE BEEN-1.ALL SINCORPORATED.MEAN ROOF
/`/•�,P r��\1, HEIGHT MUST BE LESS THAN 60 FEET.
DOCUMENT CONTROL DATE CAD DC ENGINEER CONTACT INFORMATION ENGINEERING STAMP CONTRACTOR CONTACT INFORMATION CONTRACTOR LOGO CUSTOMER: SHEET NAME:
ISSUED FOR PERMIT 11-19-20 AC DM ENGIPARTNERS LLC ,11,,11,, TITAN SOLAR POWER FL LUIS PENH -
REV DESCRIPTION DATE AD QC ,,.•'GONz , DIJItaIIy 51(311" PROJECT ADDRESS: COVER SHEET
C.A.32661 °EeENSEFrso by Rafael A 12221 N US HIGHWAY 301 * TITAN
255 GIRALDA AVE ?e:' en a4 ' EGOf1ZaIeZ SD10 7827 DAVIE RAY OR
CORAL GABLES,FL 33134 ` A � Date: THONOTASASSA,FL 33592 ZEPHYRHILLS,FL 33540 PROJECT ID: ENGINEER OF RECORD: SHEET TITLE:
�� S 0 L A R POWER ENG.RAFAEL A.GONZALEZ SOTO,PE C-1
DESIGN ENGIPARTNERS.COM %o'+:o°}og.W.c 2020.1114 (813)982-9001 SHEETS:TSP58443 DATE:ONnl ENva 57:09-0500 PARCEL NUMBER:
35-25-21-0140-00900-0420 11-19-2020 1 OF 9
833-888-3644 #5013008093
NORTH
' V
EXISTING ELECTRICAL METER--[
PV DISCONNECT-� -_
PV STRING INVERTER
;r# ,III►►,i,,, LOCATION OF NEAREST URGENT CARE FACILITY
ADDRESS:
No 83104 % PHONE NUMBER:
"PROPERTY SIDE FACING STREET" (
* Z NOTES:
F
1fl `•,5 ��1OI� �� 1. INSTALLERS SHALL DRAW IN DESIGNATED SAFETY AREA AROUND HOME
� ` ••,• a .i 2. INSTALLERS SHALL UPDATE NAME ADDRESS AND PHONE NUMBER OF NEAREST
SAFETY PLAN �� t`.` ' � URGENT CAR FACILITY RELATIVE TO THE SITE BEFORE STARTING WORK
N.T.S.
DOCUMENT CONTROL DATE OC ENGINEER CONTACT INFORMATION ENGINEERING STAMP CONTRACTOR CONTACT INFORMATION CONTRACTOR LOGO CUSTOMER: SHEET NAME:
ISSUED FOR PERMIT 10 AC DM ENGIPARTNERS LLC TITAN SOLAR POWER FL LUIS PENH
REV DESCPoPTION DATE D OC ,,.."""""` Dlgltally signed ������► PROJECT ADDRESS: SAFETY PLAN
C.A.32661 °E P:G°.".Z"fez°•,, 12221 N US HIGHWAY 301
255GIRALOAAVE AVE b Rafael A T I T A N
p;:,�ExsA.., y A 7827 DAVIE RAY DR
CORAL GABLES,FL 33134 '•y,G,(/u� _-Gonzalez Soto THONOTASASSA,FL 33592 ZEPHYRHILLS,FL 33540 PROJECT ID: ENGINEER OF RECORD: SHEET TITLE:
t°yea Date: 5 0 L A R P O W E R ENG.RAFAEL A.GONZALEZ SOTO,PE C-2
- DESIGN@ENGIPARTNERS.COM �. '�<oxio!• c`2020.11.24 ' ' (813)982-9001 PARCEL NUMBER: TSP58443 DATE: SHEETS:
833-888-3644 04:57:17-0500 #EC13008093 35-25.21-0140-00900-0420 2 O F 9
tt-tazazo
WIRE SIZES,QUANTITY,&TYPE RACEWAY SIZE,TYPE,LOCATION&INFO. WIRE AMPACITY CALCULATIONS ADDITIONAL INFORMATION
125%OF WIRE DE-RATED CALCULATION
CONDUCTOR NEUTRAL GROUND RACEWAY RACEWAY RACEWAY HEIGHT OUTPUT OUTPUT MIN - VOLTAGE CONDUIT
WIRE TAG DIST. VOLTA
QTY.SIZE&TYPE QTY.SIZE&TYPE QTY.SIZE&TYPE SIZE&TYPE LOCATION ABOVE ROOF CURRENT CURRRENT OU OCPD WIRE AMBIENT #OF FINAL DROP% FILL%
RATING TEMP COND. AMPACITY
DC(BEFORE JB) 6 #10 AWG PV WIRE N/A (1)#8 AWG BARE COPPER NOT APPLICABLE UNDER ARRAY 1/2"TO 3-112" 15A 18.8A 20A 40A X 0.76 X 1 =30.4 A 10 FT, 350V 0.11% 6.4%
DC(AFTER JB) (6)#10 AWG THWN-2 N/A (1)#8 AWG THWN-2 3/4"EMT CONDUIT ABOVE ROOF i 1/2"TO 3-1/2" 15A 18.8A 20A 40A X 0.76 X 0.8=24.3 A 20 FT. 350V 0.21% 8.1%
AC(INVERTER TO METER) (2)#6 AWG THWN-2 (1)#6AWG THWN-2 (1)#8 AWG THWN-2 3/4"EMT CONDUIT EXTERIOR WALL "N/A" 42A 52.5A 60A 75A X 0.76 X 1 =57.0 A 5 FT. 240V 0.1% 7.7%
STRING#1
A1.1 A1.2 A1.3 A1.4 A1.5 A1.6 A1.7 At$ A1.9 A1.10 A1.11 A1.12 A1.13 A1.14
1 � r�
EXISTING UNDERGROUND SERVICE
STRING#2 240V/120V 200A BUS BAR
3#2/0 THWN-2
82.1 132.2 B2.3 B2.4 B2.5 B2.6 B2.7 C2.8 C2.9 C2.10 C2.11 C2.12 C2.13 0
/i1, INVERTER TOTAL OUTPUT:42A
= _ • '
= _ +_ 10 SAFETY RATING(125%): 52.5A
• TOTAL PV SYSTEM OCPD: 60A
2
STRING#3 PV RAILS TO BE BONDED WITH#8 BARE WIRE 6___________ / 4JUNFUSE1,_116A13 9 )150A MAIN BREAKER RATING: 150A
GOA BUS BAR RATING: 200A
C3.1 C3.2 C3.3 C3.4 C3.5 C3.6 C3.7 C3.8 C3.9 03.10 D3.11 D3.12 D3.13 7 C�
120%BACKFEED RATING: 90A
1 iL/L NEMA3R 1#6 THWN-2
ONE LINE RISER DIAGRAM
N.T.S.
LEGEND:
6#10 PV WIRE
(40)Q.PEAK BLK-G4.1 290W BY QCELL- v' , ) d.
2 1 #8 BARE WIRE GROUND 3 NEMA3R JUNCTION BOX Y � •....
REFER TO D-1 SHEET 3/4"EMT CONDUIT 'k '• ` c'-4
6#10 THWN-2 2#6 L1,L2 THWN-2 1 #8 TWHN-2 GROUND _� E:Q '
4 1 #8 THWN-2 GROUND 5 SE1000OH-US BY SOLAREDGE-REFER TO D-3 SHEET 6 1 #6 THWN-2 NEUTRAL 3/4"EMT CONDUIT N�. 83104
3/4"EMT CONDUIT
2#6 L1,L2 THWN-2
7 PV SYSTEM DISCONNECT RATED 60A 8 1 #6 THWN-2 NEUTRAL 9 PV INTERCONNECTION POINT j 1
3/4 EMT CONDUIT
10 UTILITY ELECTRICAL SERVICE 11 NOT USED 12 NOT USED
DOCUMENT CONTROL DATE D DC ENGINEER CONTACT INFORMATION ENGINEERING STAMP CONTRACTOR CONTACT INFORMATION CONTRACTOR LOGO CUSTOMER: I SHEET NAME:
ISSUED FOR PERMIT 11-18-2° AC DM ENGIPARTNERS LLC ,,,,,,,,, TITAN SOLAR POWER FL LUIS PENA III
REV DESCRIPTION DATE D OC ll ,, Digitally signe PROJECT ADDRESS: ONE LINE RISER DIAGRAM
C.A.32661 Ptis•"a�EFo.,by Rafael A 12221 N US HIGHWAY 301 T I T A N
255 GIRAES,AVE =GOnzaleZ Soto 7827 YRHI RAYDR
CORAL GABLES,FL 33134 'i .3109 +_ THONOTASASSA,FL 33592 ZEPHYRHILLS,FL 33540 PROJECT ID: ENGINEER OF RECORD: SHEET TITLE:
/-Date: SOLAR POWER ENG.RAFAEL A.GONZALEZ SOTO,PE E-1 toalo?'
DESIGN@ENGIPARTNERS.COM •....... �e,••' 2020.11.24 (813)982-9001 PARCEL NUMBER: TSP58443
o,SSION�L EN,. 045725-050 DATE: SHEETS:
"��•.,,�,,,.,�' 35-25-210140-00900-0420 11-182020 3 OF 9
833-668-3844 #EC13008093
INVERTER#1
LABEL LOCATION:
WARNING ; ; &WARNING DUAL POWER SOURCE i POINT OF
PHOTOVOLTAIC SYSTEM CIRCUIT IS BACKFED INTERCONNECTION
ELECTRICAL SHOCK HAZARD LABEL LOCATION: '` 15 AMPS LABEL LOCATION: PER CODE:NEC 690.64
DO NOT TOUCH TERMINALS AC DISCONNECT, •. •• 500 VOLTS INVERTER NEC 705.12(D)(4)
TERMINALS ON BOTH LINE AND PER CODE:NEC 690.52 LABEL LOCATION:
POINT D INTERCONNECTION 480 VDC ,WARN LNG
LOAD SIDES MAY BE ENERGIZED PER CODE:NEC 690.17(E) POINT OF
IN THE OPEN POSITION IDIuJIIuJiiI 42 AMPS INVERTER OUTPUT CONNECTION.DO NOT
RELOCATE THIS OVERCURRENT DEVICE INTERCONNECTION
PER CODE: NEC 690.64
NEC 705.12(D)(4)
WF11
LABEL LOCATION: aCAUTI ON LABEL LOCATION:
42 A AC DISCONNECT MAIN SERVICE PANEL
WARNING PER CODE: NEC 690,54 PHOTOVOLTAIC SYSTEM CIRCUIT IS BACKFED PER CODE:NEC 705.10
• 1 •• •A 240V NEC 690.45(B)(5)
ELECTRICAL SHOCK HAZARD
LABEL LOCATION:
IF A GROUND FAULT IS INDICATED INVERTER
NORMALLY GROUNDED CONDUCTORS PER CODE:NEC 690.05(C) LABEL LOCATION:
POINT OF
MAY BE UNGROUNDED AND ENERGIZED • • • INTERCONNECTION
PER CODE:
LABEL LOCATION:
NEC 690.33(E)(2)
AC DISCONNECT
` POINT OF INTERCONNECTION LABEL LOCATION:
R
PER CODE:NEC 690.58(C) DC DISCONNECT
WANINGR PER CODE:NEC 690.14(C)(2),
LABEL LOCATION: SHUTDOWN
NEC 690.53
TURN OFF PHOTVOLTAIC AC DISCONNECT, MAIN PANEL -
PER CODE: NEC 110.27(C)
AC DISCONNECT PRIOR TO OSHA 1910.145(f)(7)
WORKING INSIDE PANEL CAUTION: SOLAR ELECTRIC
SYSTEM CONNECTED
1
• • • LABEL LOCATION: LABEL LOCATION:POINT OF INTERCONNECTION
WARNING AC DISCONNECT PER CODE:NEC 690.15,NEC 690.13(B)
• PER CODE: NEC 690.54
ELECTRICAL SHOCK HAZARD LABEL LOCATION:
DC DISCONNECT, INVERTER j �i��
THE DC CONDUCTORS OF THIS PER CODE:NEC 690.35(F) .
N
PHOTOVOLTAIC SYSTEM ARE UNGROUNDED
AND MAY BE ENERGIZED
' ■ • • • • "; No. 83104
i ® STA� OF 41
SAFETY LABELS DATA % �` !�LORtD@PV N.T.S. LABEL LOCATION:
MAIN SERVICES DISCONNECT,DC CONDUIT
PER CODE:NEC 690.31 (E)(3)
DOCUMENT CONTROL DATE AD DC ENGINEER CONTACT INFORMATION ENGINEERING STAMP CONTRACTOR CONTACT INFORMATION CONTRACTOR LOGO CUSTOMER: SHEET NAME:
ISSUED FOR PERMIT 11-18-40 AC DM ENGIPARTNERS LLC LUIS PENA
TITAN SOLAR POWER FL PROJECT ADDRESS:
Digitally signed
SAFETY LABELS
REV DESCRIPTION DATE D DC C.A.32661 `•p.GONZAf1.,� 12221 N US HIGHWAY 301
255 GIRALDA AVE a4 ''3�rysF••:fo''%by Rafael A 41r TITAN 7827 DAVIE RAY DR
T' e3w ' Gonzalez Soto ZEPHYRHILLS,FL 33540 PROJECT ID: SHEET
ENGINEER OF RECORD: TITLE:
CORAL GABLES,FL 33134 ;+y,,G��y�o,"� += THONOTASASSA,FL 33592
' STA Date: S 0 L A R P 0 W E R ENG.RAFAEL A.GONZALEZ SOTO,PE E-2
DESIGN ENGIPARTNERS.COM '�o•:ton,uS'' 2020.11.24 (813)982-9001 — — — TSP58443
EI •••0457:37-0500� PARCEL NUMBER: TSP58443
DATE:35-2&21-0140-00900-0420 11.1_zozo I8NT
ETS: 4 OF
9
833-888-3644 #EC13008093
r
ULTIMATE WIND SPEED 140 mph
NORTH NOMINAL WIND SPEED 137 mph
RISK CATEGORY II
EXPOSURE CATEGORY B
ROOF SLOPE 23
ROOF TYPE HIPPED
PRESSURE ZONE: 1&2
ARRAY "B" MEAN ROOF HEIGHT: 23.05
TILT=23° PERIMETER WIDTH: 4
AZIMUTH=351°(N) 4' 0.85
KZT 1.0
KH 0.701
4' VELOCITY PRESSURE =0.60*0.00256* K V
1 VELOCITY PRESSURE ASD 17.17
i oss EXTERNAL PRESSURE COEFFICIENT Z1 0.5 -0.9
OBS EXTERNAL PRESSURE COEFFICIENT Z2 0.5 -1.7
zs .. Bza t /r EXTERNAL
_L4 EXTERNAL PRESSURE COEFFICIENT Z3 0.5 -2.6
I SOLAR MODULE
INTERNAL PRESSURE COEFFICIENT 0.18
° TYP.SEE 2-1
ZONES PRESSURES MAX. I MAX.
OBS (PSF) SPAN(FTp CANTILEVER(IN):
-
_ .- ROOF MOUNTS 1 -18.54 6' 24"
OBS \' LOCATED AT CENTER 2 -32.28 4' 16"
_ .__.� OF ROOF TRUSS-TYP. 3 -32.28 _4' 16"
TOTAL ROOF AREA 1 s .-ft
TOTAL MODULES: 40
— moss �._ _ WOOD TRUSSES/RAFTERS TOTAL PHOTOVOLTAIC AREA: 718.9 .-ft
• - ° LOCATION-INSTALLER
OBS MUST VERIFY IN FIELD WIND LOAD. PSF : -32.28
I ■ - _LiiI- - TOTAL WIND LOAD LBS : -23 207.4
_ OBS OBS _ TOTAL ROOF MOUNTS: 87
ARRAY "C" OBS - - -� TENSION FORCE PER MOUNT LBS: 266.8
AZIMUT 1_. - ARRAY "A" LEGEND & SYMBOLS
AZIMUTH=261°(W) TZIMUT
AZIMUTH=81°(E)
_-H /\ L 1 OBS ROOF OBSTRUCTIONS
- ` ARRAY#
I X MODULE #
--- � STRING #
PV MODULES
• ° - - - - - - TRUSSES OR RAFTERS
EXISTING ELECTRIC METER"
PV DISCONNECT-. THE RAIL EXTENDS A MINIMUM OF 3" ROOF MOUNTS & RAIL
FROM THE EDGE OF THE MODULE-TYP.
PV STRING INVERTER
ROOF SLOPE
L_ J
ROOF'S GENERAL NOTES: T
1-CONTRACTOR/INSTALLER TO VERIFY ROOF
CONDITIONS FOR PROPER INSTALLATION OF THE •PV SYSTEM. UL 1703 CERTIFIED
2-CONTRACTOR/INSTALLER TO NOTIFY THE 3.11 I,.* .13
MAX.PV MODULE SURFACE LOAD:55.60 psf
OWNER IMMEDIATELY OF ANY ROOF I Li APPLIED WIND LOAD:32.28 psf
DEFICIENCIES AND/OR REPAIR REQUIRED TO f f I f 1! I NOTES:
INSTALL THE PV SYSTEM. �+ /�/ Q.PEAK I -INSTALL MID CLAMPS BETWEEN
3-FOR DOES NOT ASSUME ANY RESPONSIBILITY ; GO NZA( 1//i BLK-G4.1 65.74" MODULES AND ENDS CLAMPS AT THE
FOR THE INSTALLATION OF ANY PV SYSTEM ON II " ti i� 290W END OF EACH ROW OF MODULES.
DEFICIENT ROOFS. ARRAY D �,,• OEp+l S
TILT=23° i ssa -ALUMINUM RAILS SHOULD ALWAYS BE
4-CONTRACTOR/INSTALLER ASSUMES ALL AZIMUTH=171°(S) ` ` d i SUPPORTED BY MORE THAN ONE
RESPONSIBILITY TO INSTALL AS PER K Ho x 83104 FOOTING ON BOTH SIDES OF THE
• 1 SPLICE.
MANUFACTURER STANDARDS. "PROPERTY SIDE FACING STREET" 1 7�
• � ', 39.37"--I
`�� SOLAR MODULE
STRUCTURAL ROOF PLAN & PV MODULES LAYOUT r ' ,
(j STRUCTURAL '_N.T.S. , �.ofeoDp ' N.T.S.
DOCUMENT CONTROL DATE DI QC ENGINEER CONTACT INFORMATION ENGINEERING STAMP CONTRACTOR CONTACT INFORMATION CONTRACTOR LOGO CUSTOMER: - A c i , SHEET NAME:
ISSUED FOR PERMIT 11.19.20 ACIDM ENGIPARTNERS LLC .......... TITAN SOLAR POWER FL LUIS PENH
REV DESCRIP110N DATE D OC ••"'G°xZq°"'•, Digitally signed PROJECT ADDRESS:
STRUCTURAL PLAN
C.A.32861 ;"er'BENS`F�''' by Rafael A 12221 N US HIGHWAY 301 ST I T A N
255 GIRALDA AVE ��� J e'�°o= 7827 DAVIE RAY DR
ryc e31w -Gonzalez Soto
CORAL GABLES,FL 33134 * A�'`Date: THONOTASASSA,FL 33592 ZEPHYRHILLS,FL 33540 PROJECT ID: ENGINEER OF RECORD: SHEET TITLE: �+
+/J_y� S 0 L A R P O W E R ENG.RAFAEL A.GONZALEZ SOTO,PE S-1
'°"•:100. .` . .
DESIGN(�ENGIPARTNERS.COM gg........1°,68- 20201124
, (813)982-9001 PARCEL NUMBER: TSP58443 DATE: SHEETS:
833-888-3644I #EC13008093 35-25-21-0140-00900-0420 11"18-2020 5 OF 9
CrossRail End Clamp L-Foot CrossRail Mid Clamp ' • Wet--DrI'
CrossRail 48-XL All-Season Asphalt Patch
t1 � � TTSI
•
`/ �1. 7 1 ;AaietiahWetDryCaMhbn
Mechanical Properties (� )1l + V541313,1714H
Q-� Wiz..
a4]ald ::�' tivnl 1 3 Xmas°muknu°.a,ur.ar.ruugmaefb°.re N..n
rn
rlvnia.i°r,rp+r....rga )rcr•., `—. a a ow�wroW-arme"..n..gwl va+rs°i.mwrw.gauswed wmuro°or°mare rFr.a�am.:exh
v,:hd�x.ncrh rrs...• °'°"im".nmexanyed d.Kam WdaaNva,m•d�.+a"empmw
pnwelr.aw+.o"dwwmr.w.°rrrod..rcw,°w,w+...,N.u.�rdpyw rrmew ar..r and w w°w.uw+m m reoa'a eanma ml°arm wrd axmw AIm uomN"a"a.M.nanawr
In�r1 / a ���� M'awwra.uquM•s°radr+ulrvPmuNr.atlCM'°ma"
. .sl�,•rr4eea � T� - y5RM nwa• r.-Eur1'R
ii 'e-ulN ar
Section Properties J+1
parmx�i°..rza.•..v«emas wawwnox,dr°Na.,aela.d,.,.rdeKaM�Nm,atewNa°,r.N,W.wr�.ua.daard,,d,N.som¢a,.v
a.,:mg gtaxN.d+ed tle.er.wlnne
ta'.nns" ,+m,..,. «»q.wr•da,. ApplrcAlmMATP'I gm,men"m.xw«ww Ira..vwrrc.n.m m..wr c.w.+rxva..."hm d"we n a
( Y4 " n waves:• des•dawa�.na+rmta-mw.,,rw°,isnn. aK..nvwmawr.r...eNr+ov��r...�waur ..m
g.ral4rn'(aMkird/ — )a nAh aeNva UnNeM p°40hfl r.b4. iAb ban=aw wmrad,.W aawen.rmre lv.a°aaa rom.e
Axa"d4n apgod:ecn ccsna,.xisnm.sh„eu sF aysmm ama n'° r a" No
;°�,rwm„„�„San.°nor.+r...+oa•r..roal„darw=Mrr.dm.roorl..Doalo)urr,'°Ica."wr
N cytdw' s we .wwa.+r.,w,.».rw ,.�yw.ndrrr.umrcar.�n.n.arwrw.mTros.Nmla.,.wn.,mv'..°IwKlmem«.n
♦ef.5MMxrl vasty rw ra Nadi ..s•urw+. 4Dbe3DCR FC omk.00-boo.Slrved Rl 10-nor .�"s„q ww.rY wwa9Ts_vrtnr�a.awbva-n • '°',°'0700 uvnlloMIO'elar Nara Fas°brm$000 w4k044 w°rm nlx°d..tiamuMrUw
I,.
Ir°"+p("i" 4001402 Cl SIC Don.»armor.L,erMR3p.)mm 4aedvem"vrt uNwoadMaru.°rrtN,rmasama"pNrro.v°smmrar.IFsw°°ewq.
3 Fnd Camp r Oerre4LffeeltMo.o CDxravg[Mm Caw 00.00 P 523.40+pdb°xMnpm00.0.3
I Mid tlemp 'd704141mm S,'140 701304*,a04 %epwgth.p ....oeq�v"tl rs dW 003 240340.9070100.00.32071
"v""a1°m,dad4"m°man"°'tliw«p°w...N
aTrt•D r e wwxe""w�u"''°m[saA��+c nest/ raa t a m
3 ,la' w3rx+a•dgcwiw[ gmwmrl"aacmoraehkN,.d"dnewm gd.cJwmam tadmnrwnyamrocdamnardra Domtd°nR
s ... hol � [saa,er=Naeau.w.»T.am �.ra.°n°r'm.�.°"ae�a�nea may."aw.wa. N°«a and Nr+gm°�r"—"—Pe qr ud,"agArmywsallve.u.laeamsrtv tyres..src»
Y M%3Mo3 Nr.F a,ae«arywi.ey,py�t:"gr,eyy'p ° wame.•mrnapua "'°M t°p+F De rq rrm 60µ T°6.RC"dM WMh,tMetkwrMr.xlMeNvyWnora�6m
Technical data r..normxaess«umaw,..:. a`p xk—.a..aa. aw ,w.r .0�um.TMwnmm.wrrarr..
Technical data Technical data .N a oxM m a aim m o� " `" r ncr
..,4wa n«e..aa,aaa°w.an o-rd rad
w.aaa..M.ma,p%am ma,m worn mr
sl pplotion opeaf a Used w+A e!lof wrCre dWil pores ___ _ w dA°°"rv°'" ���].�•�
. syrtmns .-. ��.�.. Stxpe oI+pWWnde _ ...., �?reYM a•gy«mmtrn armrrnmann ,p�ppry aaa.°.ow°�e)'1"°�
..` vmn - - brwg Naawr°ert!3aN"rra" ma"a"°ni.CmMw�e
... 40044400. 1599 -r+aar, v+v+w+wr.M NaNxa.s .+• amr/Wewea M
ahverPprKN M+aal Mha •
knetM VertWl°rhaaemal e.rtlelb ''1 -•~•••••••a 9fi,.Wgi9yermar&ipn rwryw .+"^a- ,W wNwN�+Ycsrma«.vamrnv°ha,s nor _�a�eaa,ntnaerKNamx.�
Yrdtl,rrumM 09o2480,1000000 n nvtlr.ma ."etc ,�Nel"u. yowl b.20 w. AVA! li r3r]
30.500 )wea•MerW eodnmm lrm.o.o 3aMd.md.r, M not Dom. No Nrm
pmMenwdWe kame am 303pTm Not NI Evxed t-footpmN(eC—ring Plti[arMWsa dL-0 Nw ti"seine utrvsb"gxvn •• _ nrM.eNna,Me-H"..erbra lre.de.a"U nk .a" /r . °°I't r'x Yd r,s• toflm. rih msysm3nm
on. eMK The"wnppgn"Mtmva U"w,ashunwall0 54040423241104044011442101 w<wnxm.mwxw°.Im-.we. ,.�ar.aa.r,wM.auu °rweweawp o3]a:4 ta. a)5'sbr0))S' Pflg1104100 I slw ]lea m3Mml]tq
00100007140
vr3XOWIrr3Sn3s°"eh"arMla'400 'lva+dnry 1.1 re++ '"n"ya.Mpamy>pnpryeea.ra WYrrc aw.uarrM.0000.00,w.eay. oils-oA 3q6 IYfl1Ya M1T ITSylllal ssib. iu. 3o5W3)3o3
W+°5tn'1ra.°K.rx<+hnrmnW YwJ:nr°uMmr".°mmr"ra
armsaa°.elarat"w."scamn Mfbnn raMewam.n•narl.dae./ram".ern• wg•rdM.-ylbar.mrn
GarmrerGWTon•PPtho. 43,04 mpa,ngltle33«]SSM9
7 3w.waeer"1!War],Tan„e"e anti-mWmmmnss°m — w'w"eYemst+oaNYrranv.idn eaeeWyarerrv.ttan n.w+...-w.. ^' %r"rc l.r3i]IF]toT k)T
rM[°m.nr..w p+n:Y"Irt�e wryn .ra.•"aeun nwd.°rca•ax,pwl mgavnrvanpe"prrn -.ire -..,.n...,..ii'a'�wr.e,ae4ry.nuyn .nana,«n ew4,m+M•+: nq:w
SPAN TABLE FOR RT MINI ANCHORAGE SYSTEM
Oto6 1 9E % 96 9666 % 9678 68 0106 FUll II!Ii I ! III !
i 8 0 8 8 6 s s 4 4
CROSSRAIL END CLAMP _-c6_ ."—x _ De ees z 6 =5= 15= =41113113 2 2 2
l 7027 1 96 % 96 % % % 93 82 73 71.27 1 a a a S 7 6 5 4 4
LAG BOLT ! 74 H 45 4I 42 n C g!e:!!!. 2 6 5 5 4 3 3 2 2 2
2t0 1 95 96 96 96 96 90 79 70 63 2830 45 1 8 8 8 7 6 5 4 4 3
! 2 96 9e %_ 96 86 75 Ss SI 72 •De es 2 8 7 6 S 5 4 3 3 3
FLASHING - 0108 1 % 96 96 96 % 90 78 68 6D Oto6 1 8 8 8 7 6 5 4 3 3
2 33 Art 77 5. 47 u 3s 32 De rees 2 5 4 4 3 3 2 2 2 0
7 k727 1 % % % % % 93 82 Ta 64 700 27 1— -J4 3 _
T. EQ.
EXIST.2X WD. I 2 92 A4 77 e5 $6 do 42 37 51 C De rees 2 5 4 4 3 3 2 2 2OTRUSSES OR p1 96 % % % 9D 79 69 61 ss 28 to45 1 a 7 7 6 5 4 4 3 ATTACHMENT DIAGRAM 2 ROWS OF RAILS PER MODULE �� RAFTERS 2 96 96 96 87 75 66 se 51 46 Degrees 2 7 6 6 s 4 3 3 3 2
1 96 96 96 96 96 96 % % % Oto6 18 8 8 8 8 8 7 6
2 96 96 % % % 52 Da rees 2 8 8 8 7 6 5 !4 f 3
C7to27 1 a 8 8 a 8 8 7
s 2 % m % 98 96 9! 82 72 64 De rees 2 8 B 8 7 68 8 8 a 8 PLACE BOLT De ee. 2 % % % % 96 % % e9 Oearees1/4"SS 18-8 BOLTAT C.L.OF114"SS SERRATED FLANGE NUT P 2 TRUSS OR O.RAFTER LAG BOLT PULL OUT CALCULATIO • .NS,'=
Spruce,Pine, Per inch Thread Depth 266Itis � No. 83104 O
" " FLUSH MOUNT SYSTEM SPAN TABLE(Inches) SS Lag Bolt 5116"x 4" ' Min.Thread Depth 0'. ! •
SECTION "A-A"
60 CELLS PORTRAIT OR LANDSCAPE Wood Strength x Thread Depth=Pull Out Strength,,;
EVEREST CROSS RAIL(48-XL VERSION N.T.S. • EXPOSURE B 266 lbs.x 3 in=798Ibs.
SEALANT - R � ', A ��/ '
Allowable Pull Out Strength per Lag Bolt 798 I� ��jjj
ROOF WIND GROUND SNOW:0 pelf Max.Pull Out Strength Required per Lag Bolt 266,8 8
SLOPE SPEED ZONE 1 ZONE 2 ZONE 3 Lag Bolt Pull Out Strength Safety Factor 2.99 � `. ` ►t7�`
R
Engineered to ASTM D 1761 ea..x= a. . n'.,a.« I (delta.) (mph) (inches) (inches) (inches) �e 1� 040444' \�
L-FOOT i"' components Dimensions In(mm 110 96 89Lag A�
Screw Installation Guidelines Uni-Rac Specs,Lag pull out(withdrawal)capa i
arz'oa°-- ,�'MImN'°Isl( sU11 n' 115 96 86 74 1.Determine location for the Mount on roof by in typical roof lumber(A$D) ° ( ( \ `
3r 1S0r drilling through the center of truss from bottom with
MMlbre:ggw � • ° ° eel 120 96 84 70 6132°drill bit, STAINLESS STEEL Lag screw speciFcations
_
2X4 RAFTERS 24"O.C. �. �iow. aafterinstallatton a 2. Merle mountIng holes for Mount on
undedayment.Mounting holes should be centered Specific °%o"Shaft,
s,m,,,,ln,m„a,°o,,ea,=,,.n°g:,ma.,, 7-27° 140 91 73 60 on the W .
RI MINI anedwrxw n =+- iWev 150 87 68 56 3.Drill I5J64^pilot hole, gravity per inch thread depth
SEE DATA SHEET ABOVE — 5rt..W 11 n°a*.m'•fi aN.taarmg—d m 4,Apply sealant to bottom of Mount
pot ASPHALT rso,000 l.dd.,r.wgmm.mrna.rz.heue 160 93 64 53 5.Place Mount over roof undedayment with holes Douglas Fir,Larch 0.50 266
SHINGLES °N w.uupv mo rvny.y.NmwlrorN m"
pw+eq,adlue ayt"Icc. 170 80 60 49 6.roof.
sealant t°bottom of Mount, PPh'sealant a
Mml nenrrclrwmha rindbN nasMrrg _ . . APPM Douglas Fir,South 0.46 235
180 75 57 48 to lag screws end fasten Mount securely to
NOTE: 5/16"SS LAG BOLT Susses. Engelman Spruce,Lodgepole Pine 0.46 235
Deck inctalla5on 7.Apply additional sealant to top assembly to be (MSR 1650 f&higher)
SEAL BASE MOUNT TO EXISTING 5/16"SS FENDER WASHER ' } sure all penetrations are seated.
ROOF UNDERLAYMENT WITH ROOF I I Asa o.t000 oa rre,w. Hem,Fir,Redwood(dose grain) 0.43 212
SEALANT AND MEMBRANE Aeddn"ddwT ZOOlbwdra p ppt m+fl•DDo00flwknse a L
Asnoo,wr.wM w--r.,lnmu..l wnw Hem,Fir(North) 0.46 235 W
°�•Ncameem"ant"'rid""""`°°""a`F 40 Southern Pine 0.55 307
r.;.� Notes:(1)Thread must be embedded in the side grain of a Trusses or other structural � w ww.r=p.m"q.mt c 1
f member integral with the building structure, ores wm°Yao w..d`"g,w"m',mm Aece,.,o mm aNe"d m..amr.ar-20d Spruce,Pine,Fir 0.42 205
(2) Lag Bolts must be located In the middle third of the structural member. eo.ed e"p.ar gm2:ec.
vs,sNex.dt.d..aere (3) These values are not valid for wet sendces. Ae efl 007141.Mep arry lm'Im d,.".a,rca .O.0.400 m.dm
SHINGLE ROOF MOUNT DETAIL & DATA "°� dng..mr��da�,pd.,�aww.•a.,7p�D sptiCe,Pine,psi
1 (4) This table does not Include shear capacities.If necessary,contact a local engineer to ro mN es,m„,s" °aroa"n m pw decoct.m. ores (E of 2 million psi entl higher
spedfy lag boIt size with regard to shear forces. a m mWr.m d".n.a e"mmnudg I",Ma eeveeeery m"Nv
(5) Install lag bolts with heed ad washer flush to surface(no gap).Do nor over-torque. gmaekm. grades of MSR and MEL) 0.50266
N.T.S. (5) Withdrawal design values for lag screw connections shall be multiplied by applicable 61'r�` Sourasa:ArneAcan Wood co 'I,NDS 2006,Table 11.2A,11.3.4.
adjustment factors If necessary.See table 10.3.1 In the American Wood Council NDS d00,44834.4.002020.0000040.0.0.0.79.710001� egad 0071
for Wood Construction.
DOCUMENT CONTROL DATE lAD QC ENGINEER CONTACT INFORMATION ENGINEERING STAMP CONTRACTOR CONTACT INFORMATION CONTRACTOR LOGO CUSTOMER: SHEET NAME: RACKING PLAN
ISSUED FOR PERMIT — - -11-1e-2o Ac DM ENGIPARTNERS LLC Digitally TITAN SOLAR POWER FL LUIS PENH
REV DESCRIPTION DATE AD DC •"' GGNIA�hq. signed by 12711 N US HIGHWAY 301 PROJECT ADDRESS:
C.A.32661
�`� :Rafael A * TITAN
7(127 DAVIE RAY DR
_ 255 GIRALDA AVE 3e�t' asrw
CORAL GABLES,FL 33134 =i .C_,�� /=Gonzalez Soto THONOTASASSA,FL 33592 ZEPHYRHILLS,FL 33540 PROJECT ID: ENGINEER OF RECORD: SHEET TITLE:
�A'"n v=Date: S 0 L A R P 0 W E R ENG.RAFAEL A.GONZALEZ SOTO,PE S-2
DESIGN ENGIPARTNERS.COM s%o'°s°p19" (813)982-9001 TSP58443
2020.11.24 ( ) PARCEL NUMBER: DATE: SHEETS: 6 OF 9
833-888-3644 04:5758-050 #EC13006093 35.25-21-0140.00900-0420 11-19-2020
r
Format 657inx39.4inxI.26in(includingframe)
(1670mmx1000mmx32mm) a "r
WBlgbt 41 451bs(18.8 kg) axe• "°"°'"
Front Cover 0.13 in(3.2 mm)thermally pre-stressed glass with anti-reflection technology
fl
Back Cover Composite film
Frame Black anodised aluminum { :bet +
Cell 6x 10 monocrystalline Q.ANTUM solar cells
lunctlonbox 2 60-3.03in x 4.37-3.54in x 0.59-0,75 in
(66-77 mm x 11I-90 mm x 15-19 mm),Protection class IP67,with bypass diodes .a.a,lcnwanruaw °°coy"`
Cable 4 mm2 Solar cable;(+)≥39.37 in(1000mm),(-)≥39 37 in(1000mm) J °r�a °
Connector Multi-Contact MC4 m MC4 iritermateable,IP68 I o�<Hem1I To cos»,
Y
POWER CLASS 286 290 295
MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS,STC'(POWER TOLERANCE+5W 1-OW)
Power at MPP2 P , [WI 285 290 295
+ „ ' , Shoit Circuit arrrent° 1sc (Al 956 9.63 9.70
e Open Circuit Voltage* Vat IV] 38.91 39.19 39.48
i3erent at MPP° la„ (Al 8.98 9.07 9,17
Voltage at MPP" V ,, [V] 31.73 31.96 32.19
With its top performance and completely black design the new F1Rciency, n [%) 2171 17.4 ≥17.7
td•PEAk BLK-ls+.1 is the Ideal solution for all residential rooftop applications MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS,NOCa
thahks to Its innovative cell technology Q.A"T1JM. The world-record cell Power at MPP2 P (WI 210.7 214,4 218.1
design was developed to achieve the best performance under real condi- StwiCircuitQrrenl' fsc (Al 7.71 777 782
tions—even with low radiation intensity and on clear,hot summer days. Ourreld tMPP*aga° V0, [V] 36.38 36.65 36.92
CurremafMPP• I, [Al 704 7.12 720
G
ELECTf ICITY CENERATI(1N COSTSVeegeatMPP° V,&P IV] 29.92 30.12 3030
'1000W/nna,25'C,spectrumAM 15G 'Measurement tolerances STC*3%i NOC.5% aSOOWrm2,NOC,spectrumAM 1.5G 'typical values,actual valuesmaydlffer
Higher yield per surface area and lower BOS costs thanks to
higher pother classes and an efficiency rate of up to 18.0%.. 9 CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE
--
- --------
Gs°100 acau At least 98%of nominal power during firstyear, X,m
x Thereafter max 05%degradation per year, G
INNOVATIVE ALL-WEATHER TECHNOLa61 =0°6 ----�' tr w' At least 92.6%of nominal power up to 10 years,
a W,,, ' '
Opti atoll yields,whatever the weather with excel lent low-light s, At least 836%of nominal power up to 25 years.
All data within measurement tolerances --r-----r-----i-----------
arxl temperature behavior. Full vramanties in accordance with the war anty S
terms of the B CELLS sales organisation of-your ar _ i I i
respective country.
ENDURING HIGH PERFORMANCErRAoaN[ttwm=1
Long-term yield security with Anti-PI D Technology', '
L W 1a w e x as Typical module performance under low irradiance conditions in
Hot-Spat-Protect and Traceable Qual iiy Try.Q'r"•. P �a a��"s rrzo°, tiracs comparison to STC conditions(25°C,1000W/m').
1b
EXTREME WEATHER RATING GCRtS TEMPERATURE COEFFICIENTS
_ . +xasw err r Temperature COetliCleIN of Isc a [%/K] +0.04 Temperature Coefficient of Vac 11 [%/K] -0.28
High-tech aluminum alloy frame,certified for high snow T4�MMMly[!II mp r, y [%/K) -0.39 Normal OperatigCellTempeattre HOOF ('Fl 113±54(45±3°C)
(540OPa)and wind loads(400OPa) regarding IEC. re ag�re CoeNidem orP
fAf1 •• , r• r _ — yj
MPJ(IMUM COST REDUCTIONS Maximum System VolrageVs c [VI 1000(JEC)11000(UL) safety Class II
Up to'l O% loaner logistics costs due to higher module Maxtmlmt SedesFuse Rating (ADO] 20 Fire Rating C(IEC)/TYPE I(UL)
Ucapacity0%Lowe Design load,push(UL)2 [ibs/ff2] 75(3600 Pa) Permitted Modde temperature -40°F up to+185°F
��� on coldfnuous duty (-40°C up to+85°C)
box
E"ter Design load,pull(ULP [Ibs/R2] 55.6(2666 Pa) 2 see installation manual
� E
od itA RELIAEiLE INVESTMENT mlfrrgAit 2t1R4
Inclusive 12 par product warranty and 25-year e r r r e
2 IU dU032587 ow ' UL 1703:VDE Quality Tested:CE-complient; Number of Modules per Pallet 32 8
linear perfoimance.guarantee-, IEC 61215(Ed,2);IEC 61730(Ed.1)application class A
Number of Pallas pet 53'Coma[ner 30 `
Number IN Pallets per 4D'Container 26��
? AFTtstcondRions:Cells at-1500V • �'
DVE CE Pallet Dimensions(LxWxH) 68,7inx45.3inx46.4hi k ' ,ICE '' •
again g/ntatded,with cdnduct Ira c r•, us
.1 (1745mmx1150mmx117Q1hm) ' ' .Chi
tai foi I muered module surface,25"C,
THE IDEAL SOLUTION FOR: 166h PaletWeight 14351Lis(61 No. 83
O
2 See data sheet 6n rear for further- NOTE:Installation instructions must be followed.See the installation and operating manual or contact our technical service department for further information on approved installatiewal usl 4 ' �.
Roo MIW5c) -information. of this product, $ "'
resdernim buitHrgs
Hanwha O CELLS America Inc. 1
300 Spectrum Center Drive,Suite 1250,Irvine,CA 92618,USA I TEL+1 949 748 59 96 I EMAIL inquiryeus.q-cells.com I WEB w,vw.q-Cells.us Y//1 ,• r;,
rl/N{1 s
EfWner Vd In GQ[7Mily CELLS —�.�
DOCUMENT CONTROL DATE AD OC ENGINEER CONTACT INFORMATION I ENGINEERING STAMP CONTRACTOR CONTACT INFORMATION CONTRACTOR LOGO CUSTOMER: SHEET NAME:
LUIS
ISSUED FOR PERMIT 11-19-20 AC DM PENA PV MODULES DATASHEET
E ET
ENGIPARTNERS LLC Digitally TITAN SOLAR POWER FL PROJECT ADDRESS:
W REV DESCRIPTION DATE ADoc C.A.32661 F`p,�GGZi�E• signed by 12221 N US HIGHWAY 301 T I T A N
° caws s 7827 DAVIE RAY DR
_ 255 GIRALDA AVE 'Qe`J F.r o':Rafael A
CORAL GABLES,FL 33134 '+�,"y,�J�ysia� +°Gonzalez Soto THONOTASASSA,FL 33592 ZEPHYRHILLS,FL 33540 PROJECT ID: I ENGINEER OF RECORD: ISHEETTITLE:
5 0 L A R P O W E R ENG.RAFAEL A.GONZALEZ SOTO,PE I D-1 ENGIPARTNERS.COM 'a?o'` toa,o!•`�� Date: 813 982-9001 TSP58443
�S8IJNAl � 2QZQ•]]•24 ( ) PARCEL NUMBER: DATE: SHEETS:
35-25-21-0140-00900-0420 11-19-2020 7 OF 9
833-888-3844 04:5807-05'00' #EC130o8093
/ Power Optimizer
11110
For North America
Power Optirnizer P320 / 340 / P370 P400 / P401 / P405 / P485 / P505
For North America •
IP3201 P340 / P370 / P400 / P401 / P405 / P485 / P505
I
m INPUT
Rated Input DC Powerm 320 340 370 400 405 485 505 W
Absolute Maximum Input Voltage 48 60 80 60 125m 831 Vdc
(Voc at lowest temperature)
MPPT Operating Range 8-48 8-60 8-80 8-60 12.5-105 12.5-83 Vdcr
J lUII!AYJILIIdIUP Q ______________________ ________________________________ _________ _________ ____________________ _________
Maximum Short Circuit Current 11 10.1 11.75 11 14 Adc
Maximum DC Input Current 13 75 12.5 14.65 12.5 17.5 Adc
Maximum Efficiency 99.5. %
—Weighted Efficiency 98.8 j 98.6 %
Overvoltage CategoryII
OUTPUT DURING OPERATION(POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER)
Maximum Output Current I 15 Adc
Maximum Output Voltage 60 85 Vdc
OUTPUT DURING STANDBY(POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF)
Safety Output Voltage per Power
Optimizer 1±0.1 vt)c
STANDARD COMPLIANCE
EMC FCC Part15 Class B,IEC6100 0-6-2,IEC61000-6-3
Safety IEC62109-1(class II safety),UL1741
Material UL94V-0 UV Resistant
MRoHS Yes _
INSTALLATION SPECIFICATIONS
Maximum Allowed System
Voltage 1000 Vtic
Compatible inverters All SolarEdge Single Phase and Three Phase inverters
129±153x335 129x153 x29.5 129x162x59/ mm
Dimensions(WxLxH) 120±153x27.5/5.ix6±51 /5.1±6x1.3 /5.1±6x1.16 129x159x49.5/5.1x6.3x1.9 5.1±6.4x23 /in
Weight(including cables) 630/1.4 750/1.7 655/1.5 845/19 1064/2.3 gr/Ib
Input Connector MC41'l Single or dual MC4R
MC4mi'I
Input Wire Length 0.16/0.52 m/ft
Output Wire Type/Connector Double Insulated/MC4
Output Wire Length 0.9/2.95 1.2/3.9 m/ft
PV power optimization at the module-level Operating TemperatureRangefi 40--a85/-40-+185 C/'F
Protection Rating IP68/NEMAGP
Relative Humidity 0-100 96
Specifically designed to work with SolarEdge I Fast installation with a single bolt 11)Rated power of the module at SIC will rgtexceed the optirtazer•Rated hput DC Power'.Modules with up to tderance are allowed
(2)NEC 2017 requires max input voltage be not more than BOV
inverters (3)For other corrector types please cettact SolarEdge
I Nextgeneration maintenance with module- 14)For dual version for parallel mnnecscn of two modules use P485-4NMDMRM.In the case of an odd number of PV modules in one string,installing one P485 dual version power optimizer connected
to one PV module.When connecting a single module seal the unused Input connectors with the supplied pair of seals
■ Up to 25%more energy level monitoring (5)For ambient temperature abc e.85'C/+185•F power de-ratng is applied.Refer to Power Optimizers Temperature De-Rating Technical Note for more detals
I Superior efficiency(99.5%) / Meets NEC requirements for arc fault . _ .
protection(AFCI)and Photovoltaic Rapid
1 Mitigates all types of module mismatch losses, Shutdown System(PVRSS) Minimum String Length P320,P34L,P370, 8 10 18 h:_ ,,
from manufacturing tolerance to partial (Power Optimizers) P400,P401 '' f/,
P405,P485,P505 6 8 14
shading in GUav2
I Module-level voltage shutdown for installer Maximum String Length(PowerOptlmizer� 25 25 so .4 .,, 4�`
and firefighter safety 5700(6000 with I
Flexible system design for maximum space Maximum Power per String SE7600-US-5811400- i 5250 600U 1275Dm W t{ re•` NSF
utilization Parallel Strings of Different Lengths or Orientations Yes � - i1
No. 83j
16)For detailed string sizing information refer to http//eesolaredge.cmrsrtdt/default/iles/dnng,,sizing.,rra.pdf
m solaredge. m/sites/defauft/iles/stnng-sizin�na.pdf
(7)his riot allowed to mix P405/P485/P505 with P320/P340/P3701P400/P401 in one string
(8)A string with more than 30 optimizers does not meet NEC rapid shutdown requirements safety vdtage will be above the 30V requirement —'
(9)0 1cr gnIV Igrsallowed to installtollnptl pw15,perstring when whmaximumpower wen dcabetween each ch is tSXtDW
is2 '� S �
p0)For 277/480V grid:rt is allowed to install up to 15,ODOW per string when the maximum power difference between each string Is 2,(100W �� • '
solar �
solaredge-com @ i . '
O SdasfdgeTedtndogiosLtd All d9Msresersed SOLAREDGE,rheSderedge logo,oPttMtZED BVSOLAREDGE eretradanarta or registered pedemerla of towedgaTsmnorogiey tic. ROH �, �40r�RIp Cl site tredsnm,tam.M,orndhe,wn aetredersol¢oftta,rrasr rva owners.Date:0472020/w02,/ENGNAM Subjectlo cherga.wehurn notice la/
lC �� .....
DOCUMENT CONTROL DATE ICAD DC ENGINEER CONTACT INFORMATION I ENGINEERING STAMP CONTRACTOR CONTACT INFORMATION CONTRACTOR LOGO CUSTOMER: SHEET NAME: /f
ISSUED FOR PERMIT 11-19-20 AC DM ENGIPARTNERS LLC .............: igl y TITAN SOLAR POWER FL LUIS PENH
REV DESCRIPTION DATE AD DC -•`,,.�yA,GON2q�F,,, signed by PROJECT ADDRESS:
SMART MONITORING DATASHEET
C.A.32aa1 p;:}CENSF.,aa's R 12221 N US HIGHWAY 301 * TITAN 7827 DAME RAY DR
255GIRALDAAVE -'mPt a3tw o afaelA
CORAL GABLES,FL 33134 =* �dv'. 7,sq,'*'-Gonzalez Sot THONOTASASSA,FL 33592 ZEPHYRHILLS,FL 33540 PROJECT ID: ENGINEER OF RECORD: SHEET TITLE:
sTATEYlF S 0 L A R P 0 W E R ENG.RAFAEL A.GONZALEZ SOTO,PE D-2
';o, :toato!>•;'m Date:DESIGN ENGIPARTNERS.COM ss/0..NALEN�,.+ 2020.11.24 (813) PARCEL NUMBER:. 982-9001 TSP58443 DATE: SHEET
"i, r�
S: 8 OF
833-888-3644 ",r," 04:58:29-05-0 - #EC13008093 35-25-21-014o-00900-0420 11-19-2020 9
/ Single Phase Inverter
With H D-Wave Technology for North America
Single Phase Inverter 3000H-US SE3800 -Us SE5000H-Us SE6000H-US SE / H / / /
C
With HD-Wave Technology SE7600H-US SE10000H-U5 SE11400H-US
for North America
SE3000H-US / SE380OH-US/ SE5000H-US / SE600OH-US / OUTPUT
S E7 600 H-U S f S E 10000 H-U S /,S E 11400H-US Rated AC Power Output 3000 3300 @ 208V 5000 6000@240V 7600 10000 11400@240V00 VA
3300 @ 208V 5000 @ 208V 10000 @ 208V
3800 @ 240V 6000 @ 240V 11400 @ 240V
Maximum AC Power Output 3000 3300 @ 208V 5000 5000 @ 208V 7600 10000 10000 @ 208V VA
AC Output Voltage Mm -Horn-Max ✓ ✓ ✓ ✓ ✓ ✓ ✓ Vac
(211-240-264)
AC Output Voltage Min.-Nom.-Max ✓ ✓ ✓ Vac
(183-208-229)
AC Frequency(Nominap 59.3-60-60.5°1 Hz
O
Maximum Continuous Output 12.5 16. 21 25 32 42 47.5 A
Current @240V
Maximum Continuous Output 16 - 24 48.5 A
Current @208V
Power Factor 1,Adjustable-0.85 to 0.85
o GFDI Threshold 1 A
Utility Monitoring,Islanding Protection,
Country Configurable Thresholds Yes
INPUT
Maximum DC Power @240V 4650 r __ 5900 I 7750 I 9300 f 11800 1 15500 I 17650 W
'3 �' O Maximum DC Power @208V - 5100 - 7750 J - 15500 W
- Transformer-less Ungrounded Yes
Maximum Input Voltage. 480 Vdc
d o Nominal DC Input Voltage 380 J 400 Vdc
I . Maximum Input Current @240VPI 8.5 f 10.5. 13.5 16.5 f 20 27 1 30.5 Adc
Maximum Input Current @208Vi i 9 13.5 I 27 Adc
WI Max Input Short Circuit Current 45 Adc
Q _ n Reverse-Polarity Protection Yes
: Ground-Fault Isolation Detection 600kn Sensitivity
Maximum Inverter Efficiency 99 99.2 %
99 @ 240V
CEC Weighted Efficiency 99 96
98.5@ 208V
Nighttime Power Consumption 2.5 W
Optimized installation with HD-Wave technology 0)Foi other tegional settings please contact SolarEdge support
BA higher current source maybe used;the inverter will limitits input ainerrtto the values stated
I Specifically designed to work with power optimizers I UL1741 SA certified,for CPUC Rule 21 grid compliance
/ Record-breaking 99%weighted efficiency I Small,lightweight,and easy to install both outdoors
or indoors
/ Quick and easy inverter commissioning directly y1t 41 t I 1!!
from a smartphone using the SolarEdge SetApp I Built-in module level monitoring � CO
/ Fixed voltage inverter for longer strings I Optional:Faster installations with built-in consumption .��'� '''' tCEN , " tP •-
metering (1%accuracy)and production revenue grade
a O0/ Integrated arc fault protection and rapid metering(0.5%accuracy,ANSI C12.20) No. 831O
shutdown for NEC 2014 and 2017,per article *.
690.11 and 690.12 , Il/'
VVVttt 1�:. ,
solaredge.com Sol a r s - 'ifM`
DOCUMENT CONTROL I DATE Di QC ENGINEER CONTACT INFORMATION ENGINEERING STAMP CONTRACTOR CONTACT INFORMATION CONTRACTOR LOGO CUSTOMER: SHEET NAME:
ISSUED FOR PERMIT 11-19.20 AC OM ENGIPARTNERS LLC LUIS PENH
REV DESCRIPTION DATE D QC ,,.."����� Digitally sign TITAN SOLAR POWER FL INVERTER DATASHEET
PROJECT ADDRESS:
C.A.32661 �„GGNZq�F1'•. 12221 N US HIGHWAY 301 % TITAN
°pF•acexs ' Rafael A 7827 DAVIE RAY DR
255 GIRALDA AVE •4'`' e'.,o'';by
CORAL GABLES,FL 33134 = `Gonzalez Soto THONOTASASSA,FL 33592 ZEPHYRHILLS,FL 33540 PROJECT ID: ENGINEER OF RECORD: SHEET TITLE:
sra •e'Date: S 0 L A R P 0 W E R ENG.RAFAEL A.GONZALEZ SOTO,PE D-3
" toaw�' ¢r 2020,11.24 DATE: SHEETS:
DESIGN@ENGIPARTNERS.COM "1'ZZoNq`E , (813)982-9001 PARCEL NUMBER: TSP58443
04:58:4005'0 35-25-21-0140-00900-0420 ii-tazozo 9 OF 9
833-888-364.4 #EC13008093