Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
20-1239
City of Zephyrhills PERMIT NUMBER ' 5335 Eighth Street Zephyrhills, FL 33542 ELCMISC-001239-2020 Phone: (813)780-0020 ° Issue Date: 01/06l2021 Fax: (813)780-0021 I i Permit Type: Electric Service Replacement/Misc Prop�elrty Number Street Address 04 26 210070 00100 0060 6436 Silverado Ranch Boulevard Owner Information Permit lff VFRMNUM EEEContractor fgffffi—atip�-51111111111 Name: CHAVEZ JOSE Permit Type:Electric Service Replacement/M Contractor: EFFICIENT HOME Class of Work:Add/Alter Residential SERVICES OF FLORIDA LLC Address: 6436 Silverado Ranch Boulevard Building Valuation:$0.00 ZEPHYRHILLS,FL 33541 Electrical Valuation:$32,732.00 Phone: (727)877-9089 Mechanical Valuation: Plumbing Valuation: Total Valuation:$32,732.00 Total Fees: Amount Paid:d:$305.$305.49 Date Paid:1/6/2021 8:48:24AM P.rewject Description INSTALLATION ROOF MOUNT PHOTOVOLTAIC SOLAR Application Fees Electrical Plan Review Fee $101.83 Electrical Permit Fee $203.66 REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each subsequent reinspection. Notice: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permit required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner:Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications add fee Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. C CTOR RE PE IT OFFICE PERMI EXPIiZtS IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER lNsTR#2020201245 OR BK 10224 PG 1389 Page 1 of 1 11/30/2020 09:48AM Rcpt:2231693 Rec:10.00 DS:0.00 IT:0.00 Nikki AlvarezSowles,Esq.,Pasco County Clerk&Comptroller PREPARED BY:Steffan King EFFICIENT HOME SERVICES OF FLORIDA,LLC 9416 INTERNATIONAL CT N. ST PETERSBURG.FL 33716 Permit Number Parcel ID Number 04-26.21-DO70.00100-0060 NOTICE OF COMMENCEMENT State of Florida County of Pasco THE UNDERSIGNED hereby gives notice that improvements will be made to certain real property,and in accordance with Section 713.13 of the Florida Statutes,the following Information is provided in this NOTICE OF COMMENCEMENT. 1.Description of property(legal description): SILVERADO RANCH SUBDIVISION PHASES 2,3&4 PB 73 PG 059 BLOCK 1 LOT 6 a)Street(job)Address: 6436 SILVERADO RANCH BLVD ZEPHYRHILLS,FL 33541-2903 2.General description of improvements: INSTALL SOLAR PV SYSTEM 3.Owner Information or Lessee information If the Lessee contracted for the improvement: a)Name and address: JOSE R CHAVEZ 6436 SILVERADO RANCH BLVD ZEPHYRHILLS,FL 33541-2903 b)Name and address of fee simple titleholder(if different than Owner listed above) N/A c)Interest In property: 100% 4.Contractor Information a)Name and address: DANIEL YATES-EFFICIENT HOME SERVICES OF FLORIDA,LLC 9416 INTERNATIONAL CT N ST PETERSBURG FL 33716 b)Telephone No.: 844.778.8810 Fax No.:(optional) N/A &Surety(if applicable,a copy of the payment bond is attached) a)Name and address: N/A b)Telephone No.: c)Amount of Bond: $ S.Lender a)Name and address: NIA b)Telephone No.: 7.Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by Section 713.13(1)(a)7.,Florida Statutes: a)Name and address: NIA b)Telephone No.: Fax No.:(optional) 8.a.ln addition to himself or herself,Owner designates wA of to receive a copy of the Uenor's Notice as provided in Section 713.13(1)(b),Florida Statutes. b)Phone Number of Person or entity designated by Owner. 9.Expiration date of notice of commencement(the expiration date may not be before the completion of construction and final payment to the contractor,but will be 1 year from the date of recording unless a different date is specified): 20 WARNING TO OWNER.ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713,PART 1,SECTION 713.13,FLORIDA STATUTES,AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY.A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION.IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. Under penalty of perjury,I clare that I e d the aregoing notice of commencement and that the facts stated therein are true to the best of my knowledge and belief. JOSE R CHAVEZ (Signature of Owner or)eysee,orOwneesor s(Au(horizedOftcer0rector/ParhredManegar) (Print Name and Provide SignabaysTWOffice) The foregoing instrum nt was acknowledge before me this 20 day of November ,20 20 by JOSE R CHAVEZ as Homeowner (type of authority,a g.officer,trustee,attorney in fact) for JOSE R CHAVEZ 'as (Name of Person) (type of authority,...e.g.officer,trustee,attorney In fad) for (name of party an behalf of whom Instrument was executed). Personalty Known ❑ Produced ID ❑� Type of ID DL Notary Signature Print name Steffan IGng "V Notary Public Stale of Florida Steffen Kingg y My Commlas)an GG 253520 1-13V Expires 0612NO22 813a60-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department Data Received 844 778 _ 8810 Phone Contact for Permitting ( ) a a aaacaa aaaaa Owners Name [C4HAVEZ JOSE R Owner Phone Number 6436 SILVERADO RANCH BLVD Owners Address ZEPHYRHILLS,FL 33541-2903 Owner Phone Number Fee Simple Titleholder Name I Owner Phone Number Fee Simple Titleholder Address JOB ADDRESS 6436 SILVERADO RANCH BLVD ZEPHYRHILLS,FL 33541-2903 LOT# F SUBDIVISION SILVERADO RANCH PARCEL ID# 04-26-21-0070-00100-0060 (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED e NEW CONSTR e ADD/ALT Q SIGN = = DEMOLISH INSTALL REPAIR PROPOSED USE 0 SFR = COMM = OTHER I Solar TYPE OF CONSTRUCTION = BLOCK = FRAME = STEEL ISolar DESCRIPTION OF WORK Installing a roof mounted photovoltaic solar system BUILDING SIZE SQ FOOTAGE HEIGHT =BUILDING $32,732 VALUATION OF TOTAL CONSTRUCTION =ELECTRICAL $ AMP SERVICE 0 PROGRESS ENERGY = W.R.E.C. =PLUMBING $ =MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION G ��/ =GAS = ROOFING 0 SPECIALTY = OTHER FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES NO BUILDER F _ COMPANY SIGNATURE REGISTERED I Y/N FEE CURREN Y/N Address License# ELECTRICIAN COMPANY EfiaentHomeServicesofFlorida SIGNATURE REGISTERED I Y/N FEE CURREN TIT N Addres License# PLUMBER COMPANY SIGNATURE REGISTERED Y/N FEE CURREN Address License# MECHANICAL - COMPANY SIGNATURE REGISTERED Y/N FEE CURREN Y/N - Address License# OTHER COMPANY SIGNATURE REGISTERED Y/N FEE CURREN I Y/N Address License# RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date.Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster,Site Work Permit for subdivisions/large projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Fortes.R-O-W Permit for new construction. Minimum ten(10)working days after submittal date.Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans, "PROPERTY SURVEY required for all NEW construction. 444 Directions: Fill out application completely. Owner&Contractor sign back of application,notarized If over$2600,a Notice of Commencement is required.(A/C upgrades over$7500) Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences(PloVSurvey/Footage) Driveways-Not over Counter if on public roadways..needs ROW T 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department NOTICE OF DEED RESTRICTIONS:The undersigned understands that this permit may be subject to"deed"restrictions"which may be more restrictive than County regulations.The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES:If the owner has hired a contractor or contractors to undertake work,they may be required to be licensed in accordance with state and local regulations.If the contractor is not licensed as required by law,both the owner and contractor may be cited for a misdemeanor violation under state law.If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work,they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847-8009. Furthermore,if the owner has hired a contractor or contractors,he is advised to have the contractor(s)sign portions of the"contractor Block"of this application for which they will be responsible.If you,as the owner sign as the contractor,that may be an indication that he is not property licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES:The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings,change of use in existing buildings,or expansion of existing buildings,as specified in Pasco County Ordinance number 89-07 and 90-07,as amended.The undersigned also understands,that such fees,as may be due,will be identified at the time of permitting.It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a"certificate of occupancy"or final power release.If the project does not involve a certificate of occupancy or final power release,the fees must be paid prior to permit issuance.Furthermore,if Pasco County Water/Sewer Impact fees are due,they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713,Florida Statutes,as amended):If valuation of work is$2,500.00 or more,I certify that I,the applicant, have been provided with a copy of the"Florida Construction Lien Law—Homeowner's Protection Guide°prepared by the Florida Department of Agriculture and Consumer Affairs.if the applicant is someone other than the"owner,I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner"prior to commencement CONTRACTOR'S/OWNER'S AFFIDAVIT:I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction,zoning and land development.Application is hereby made to obtain a permit to do work and installation as indicated.I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction,County and City codes,zoning regulations,and land development regulations in the jurisdiction.I also certify that 1 understand that the regulations of other government agencies may apply to the intended work,and that it is my responsibility to identify what actions I must take to be in compliance.Such agencies include but are not limited to: Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands,Water/Wastewater Treatment. Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. Army Corps of Engineers-Seawalls,Docks,Navigable Waterways. Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. US Environmental Protection Agency-Asbestos abatement. - Federal Aviation Authority-Runways. I understand that the following restrictions apply to the use of fill: Use of fill is not allowed in Flood Zone"V"unless expressly permitted. If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume"will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. If the fill material is to be used in Flood Zone"A" in connection with a permitted building using stem wall construction,I certify that fill will be used only to fill the area within the stem wall. If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties,the owner may be cited for violating the conditions of the building permit issued under the attached permit application,for lots less than one(1) acre which are elevated by fill,an engineered drainage plan is required. If I am the AGENT FOR THE OWNER I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction.I understand that a separate permit may be required for electrical work,plumbing,signs,wells,pools,air conditioning,gas,or other installations not specifically included in the application.A permit issued shall be construed to be a license to proceed with the work and not as authority to violate,cancel,alter,or set aside any provisions of the technical codes,nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans,construction or violations of any codes.Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance,or if work authorized by the permit is suspended or abandoned for a period of six(6)months after the time the work is commenced.An extension may be requested,in writing,from the Building Official for a period not to exceed ninety(90)days and will demonstrate justifiable cause for the extension.If work ceases for ninety(90)consecutive days,the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY.IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ' RNEY-BEFORE RECORDING YOU NOTICE OF COMMENCEMENT. FLORIDA JURAT(F.S.11 03) OWNER OR AGENT le CONTRACTOR Subscribed and swo (or affirmed)before this Subscribed and swo (or firmed)before me this 11/27/2020 by D el Yates 11/27/2020 by Da iel tes Who is/are persona known to me or has ave produced Who is/are ppersonally known to me or hasihave produced DL as identification. DL as identification. Notary Public Notary Public GG 2 3520 G 352 inion Nq Com isvoy No. Steffan k ng teffan king Name of Notary typed,printed or stamped Name of Notary typed,printed or stamped 00 Pt`�t• Notary Public State of Florida Rig State of Florida Steffan King g y g My Commission GG 253520 ion GG 253520 �jq�o Expires 0812812022 8I2022 DIRECTORY OF PAGES SCOPE OF WORK P-1 49743 PV-1 PROJECT SUMMARY THIS PROJECT INVOLVES THE INSTALLATION OF A PV-2 SITE PLAN PHOTOVOLTAIC POWER SYSTEM.SOLAR PANELS WILL BE RACKED USING A PREENGINEERED RACKING SYSTEM.THE PV-3 SINGLE-LINE DIAGRAM RACKED MODULES WILL BE ELECTRICALLY CONNECTED WITH DC TO AC POWER INVERTERS AND INTERCONNECTED TO THE PV-4 SAFETY LABELS LOCAL UTILITY USING MEANS AND METHODS CONSISTENT WITH THE RULES ENFORCED BY THE LOCAL UTILITY AND PV-5 ATTACHMENT PLAN PERMITTING JURISDICTION. PV-6 ATTACHMENT DETAILS THIS DOCUMENT HAS BEEN PREPARED FOR THE PURPOSE OF PV-7 FIRE SAFETY PLAN W 0 DESCRIBING THE DESIGN OF A PROPOSED PV SYSTEM WITH MODULE DATASHEET ENOUGH DETAIL TO DEMONSTRATE COMPLIANCE WITH > APPLICABLE CODES AND REGULATIONS.THE DOCUMENT Cl) J ARRAY WIRING BOX DATASHEET SHALL NOT BE RELIED UPON AS A SUBSTITUTE FOR >- m X INVERTER DATASHEET FOLLOWING MANUFACTURER INSTALLATION INSTRUCTIONS. Cn = Lf) THE SYSTEM SHALL COMPLY WITH ALL MANUFACTURERS M MOUNTING SYSTEM DATASHEET LISTING AND INSTALLATION INSTRUCTIONS,AS WELL AS ALL w z a. APPLICABLE CODES.NOTHING IN THIS DOCUMENT SHALL BE J Q MOUNTING SYSTEM ENGINEERING LETTER INTERPRETED IN A WAY THAT OVERRIDES THEM. CONTRACTOR IS RESPONSIBLE FOR VERIFICATION OF ALL UL 2703 GROUND AND BONDING CERTIFICATION '. CONDITIONS,DIMENSIONS,AND DETAILS IN THIS DOCUMENT 0 O Cn ANCHOR DATASHEET y'°r Q J •• 0 MapdataO2020 SYSTEM DETAILS Q _ PROJECT DETAILS NEW GRID-INTERACTIVE O LV 6436 SILVERADO RANCH BLVD, 1 PLOT DESCRIPTION PHOTOVOLTAIC SYSTEM WITH NO >- PROPERTY ADDRESS BATTERY STORAGE > C/, _ ZEPHYRHILLS,FL 33541 US PV-1 SCALE: NTS Q J ZONING RESIDENTIAL DC RATING OF SYSTEM 10.72KW LLl \(n LL.I USE AND OCCUPANCY ONE-OR TWO-FAMILY DWELLING sr� AC RATING OF SYSTEM 7.92KW ?� (0 N CLASSIFICATION GROUP(GROUP R3) AC OUTPUT CURRENT 33.OA 0 UTILITY COMPANY DUKE ENERGY FLORIDA INVERTER(S) 33 X ENPHASE IQ7-60-2-US ELECTRICAL CODE 2014 NEC(NFPA 70) MODULE APTOS SOLAR DNA-120 325 FIRE CODE 2015 NFPA 1 (2)BRANCH OF 16 IQ7-60-2-US MICROINVERTERS OTHER BUILDING 2017 FL BUILDING CODE s3s ARRAY WIRING a++�++ CODES (1)BRANCH OF 1 IQ7-60-2-US 2 US +rr� MICROINVERTERS ' CONTRACTOR INFORMATION ® zeN® North =ti��•• ••••�,/`�2 COMPANY EFFICIENT HOME SERVICES INTERCONNECTION DETAILS _ :y o : CHAP NEW LOAD-SIDE AC CONNECTION ; w;uwi F POINT OF CONNE 9416 INTERNATIONAL CT,ST. PER NEC 705.12(D)(2)(3)(B)AT MSP o a � ADDRESS Zephyrhills Zephyrhdls ; CTION PETTERSBURG,FL 32907 West UTILITY SERVICE 120/240V1 •J c�� PHONE NUMBER (844)778-8810 — ' :;er', LOCATION MAIN SERVICE PANEL W/200A �'�,�3.(�j• ••'Q,OI ` CONTRACTOR Zephyrhdls BUSBAR 175A MCB(DEBATED) SIGNATURE South SITE DETAILS •, � SUMMARY hapel ASHRAE EXTREME LOW 1°C(34°F) PROJECT This item has been signed and sealed by ASHRAE 2%HIGH 34°C(93°F) Reyes Manuel Ruiz Donate, 88991 PE on 11/19/2020 Di itall si ned DOC ID:149743-184646-1 using a Digital Signature. Re es Digitally g 2 LOCALE CLIMATE DATA SOURCE ST.PETERSBURG CLEAR(KSPG) DATE:11/19/20 Y by Reyes Ruiz- pV 1 SCALE: NTS • Donate WIND SPEED 140 MPH(ASCE7-10) CREATOR: Printed copies of this document are not considered Ru IZ- RISK CATEGORY II REVIEWER: signed and sealed and the SHA authentication code Date: must be verified on any electronic copies. 2020.11.19 WIND EXPOSURE B REVISIONS Donate 15:30:15-05'00' ALL WORK SHALL COMPLY WITMVAIUNG CODES FLORIDA SUil")ING COD REVIEW DATED 1 020 I REYES M RUIZ DONATE PE# 88991 AN ENGINEER LICENSED PURSUANT TO CHAPTER 471, NATIOPNALFLECTREC .c7DE CERTIFY THAT THE PV ELECTRICAL SYSTEM AND ELECTRICAL COMPONENTS ARE AND THE C TY O 1 PHYRHILLS CITY OF ZEPHYRHI L DESIGNED AND APPROVED USING THE STANDARDS CONTAINED IN THE MOST RECENT `'"`'" PLAN EXAMINER VERSION OF THE FLORIDA BUILDING CODE. PV-1 N GENERAL NOTES P-149743 EQUIPMENT LIKELY TO BE WORKED UPON WHILE 1 ENERGIZED SHALL BE INSTALLED IN LOCATIONS THAT SATISFY MINIMUM WORKING CLEARANCES PER NEC 110.26. CONTRACTOR SHALL USE ONLY COMPONENTS LISTED 2 BY A NATIONALLY RECOGNIZED TESTING LABORATORY FOR THE INTENDED USE. CONTRACTOR IS RESPONSIBLE FOR FURNISHING ALL 3 EQUIPMENT,CABLES,ADDITIONAL CONDUITS, RACEWAYS,AND OTHER ACCESSORIES NECESSARY W O FOR A COMPLETE AND OPERATIONAL PV SYSTEM. (N)PROPOSED ROOF-MOUNTED PHOTOVOLTAIC = M ARRAY.6:12(27°)SLOPED ROOF,33 PV MODULES (� (BLACK FRAME,BLACK BACKSHEET),254°AZIMUTH w Z J (N)AC COMBINER(Cl),OUTDOOR,OUTPUT CIRCUIT i O CONDUCTORS SHALL BE RUN IN PVC-40 CONDUIT O SURFACE O ROOF NO CLOSER THAN 0.5"ABOVE ROOF () (N)VISIBLE,LOCKABLE,LABELED AC DISCONNECT LOCATED WITHIN 10 FT OF UTILITY METER(SW1), J2 = O (E)MAIN SERVICE PANEL(MSP),OUTDOOR O > 8 O5 (E)UTILITY METER,OUTDOOR 5 W ROADWAY I— \ N O 1 4 5 (9 III111N. ___ 1//tt J:y rn - �•z O O� a- J �• S•' 'i,/3,. °° ttt��. Ii11 Q0N SITE PLAN SITE PLAN PV-2 ) SCALE: 1"=20' DOC ID:149743-184646-1 DATE:11/19/20 CREATOR: REVIEWER: REVISIONS THIS LAYOUT IS SUBJECT TO CHANGE DUE TO ROOF OBSRUCTIONS. BUT PANELS ARE NOT ALLOWED TO BE PLACED IN THE FIRE SAFETY PATHWAYS. PV-2 PM1-33 P-149743 3 PVMODULE MODULES GENERAL ELECTRICAL NOTES REF. QTY. F MAKE AND MODEL I PMAX I PTC I SC I IMP r VOC I VMP I TEMP.COEFF.OF VOC I FUSE RATING MICRO- PM1-33 33 APTOS SOLAR DNA-120325 39 300W 10.43A 9.93A 40.1V32.7V -0.123V/-C(-0.31%d°C) 20A UTILITY HAS 24 HR UNRESTRICTED ACCESS TO ALL I I I- INVERTER 1 PHOTOVOLTAIC SYSTEM COMPONENTS LOCATED AT THE Q O I INVERTERS SERVICE ENTRANCE. I I I REF. QTY. MAKE AND MODEL AC VOLTAGE GROUND MAX OCPD RATING RATED POWER MAX OUTPUT CURRENT MAX INPUT CURRENT MAX INPUT VOLTAGE CEC WEIGHTED EFFICIENCY I 181N 1 161N 1 1 IN A® 11-33 33 ENPHASE IQ7-60-2-US 240V I UNGROUNDED 240W 1.OA 15.OA 48V I I 2 MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. BRANCH BRANCH BRANCH PASS-THRU BOXES AND COMBINERS I CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS + I + I © I+ L REF. QTY. MAKEANDMODEL RATED CURRENT MAX RATED VOLTAGE 3 SUNLIGHT RESISTANT PER NEC ARTICLE 300.6(C)(1)AND I Cl I ENPHASE0AGGREGATOROREQUIV. I 48A I 240VAC I ARTICLE 310.10(D). I I I DISCONNECTS I OCPDS CONDUCTORS EXPOSED TO WET LOCATIONS SHALL BE REF. QTY. MAKE AND MODEL RATED CURRENT MAX RATED VOLTAGE REF. QTY. RATED CURRENT MAX VOLTAGE rJ L —J B1 swi 1 EATONDG222URB OREQUIV. 60A 240VAC CB1 3 20A 240VAC 1 4 SUITABLE FOR USE IN WET LOCATIONS PER NEC ARTICLE 1 45A 240VAC 310.10(C). CB2 1 175A 240VAC AC COMBINER w SYSTEM SUMMARY NOTES GROUNDING NOTES ~F1 F2 F3 BRANCH 1 BRANCH 2 BRANCH 3 1 THE DC AND AC CONNECTORS OF THE ENPHASE 1O7-60-2-US AND ARE LISTED TO MEET REQUIREMENTS AS A DISCONNECT MEANS AS ALLOWED BY NEC C')r 20A 20A 20A Cl NVERTERSPERBRANCH 16 16 1 0 690.15(A).MATINGCONNECTORSSHALLCOMPLYWITHNEC690.17(E). ALL EQUIPMENT SHALL BE PROPERLY GROUNDED PER THE J AC CURRENT 16A I16A 1A 1 1 AC OUTPUT 3,840W 3,840W 24OW ®ENPHASE SYSTEM MEETS REQUIREMENTS FOR PHOTOVOLTAIC RAPID SHUTDOWN SYSTEM(PVRSS),AS PER NEC 690.12. REQUIREMENTS OF NEC ARTICLES 250&690 PV DISCONNECT RAY STC POWER 10,725W PV MODULES SHALL BE GROUNDED TO MOUNTING RAILS IC )ARRAY PTC POWER 9,886W MICROINVERTER BRANCH CIRCUIT CONDUCTORS ARE MANUFACTURED ENPHASE 0 CABLES LISTED FOR USE IN 20A OR LESS CIRCUITS OF ENPHASE IQ USING MODULE LUGS OR RACKING INTEGRATED L- SW1 AX AC CURRENT 33A ®MICROINVERTERS.THEY ARE ROHS,OIL RESISTANT,AND UV RESISTANT.THEY CONTAIN TWO 12 AWG CONDUCTORS OF TYPE THHN/THWN-2 DRY/WET AND Z �� F- BOA AC POWER OUTPUT 7,920W CERTIFIED TO UL3003 AND UL 9703.THE CABLE'S DOUBLE INSULATED RATING REQUIRES NO NEUTRAL OR GROUNDED CONDUCTOR. 2 GROUNDING CLAMPS AS ALLOWED BY LOCAL JURISDICTION. ¢ LL 2 ERATED AC POWER OUTPUT 7,920W ALL OTHER EXPOSED METAL PARTS SHALL BE GROUNDED 0 A UNGROUNDED SYSTEM DC CONDUCTORS SHALL BE COLOR-CODED AS FOLLOWS.DC POSITIVE SHALL BE RED(OR MARKED RED)AND DC NEGATIVE SHALL BE C61 MAIN SERVICE PANEL BLACK(OR MARKED BLACK) USING UL-LISTED LAY-IN LUGS. Q J 45A (E)2401120V16,3W INSTALLER SHALL CONFIRM THAT MOUNTING SYSTEM HAS J L200ABUSBAR ALL METAL ENCLOSURES,RACEWAYS,CABLES AND EXPOSED NONCURRENT-CARRYING METAL PARTS OF EQUIPMENT SHALL BE GROUNDED TO EARTH AS (NI175AMAINBREAKER ®REQUIRED BY NEC 250.4(B)AND PART Ill OF ARI1CLE 250 AND EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED ACCORDING TO NEC 690.45(A).THE 3 BEEN EVALUATED FOR COMPLIANCE WITH UL 2703 i I rGROUNDING ELECTRODE SYSTEM SHALL ADHERE TO NEC 690.47 AND NEC 250.169.THE DC GROUNDING ELECTRODE SHALL BE SIZED ACCORDING TO NEC "GROUNDING AND BONDING"WHEN USED WITH PROPOSED V„ 250.166 AND INSTALLED IN COMPLIANCE WITH NEC 250.64. 0 PV MODULE. Cl) .l. CB2 LOADS ®MAX DC VOLTAGEOFPVMODULEISEXPECTEDTOBE43.1VAT1'C(1•C-25^C)X-0.123WC+40.1V=43.1V). 4 ALL GROUNDING SYSTEM COMPONENTS SHALL BE LISTED J AC 175A A A 6 PV SYSTEM DISCONNECT SHALL BE A VISIBLE KNIFE-BLADE TYPE DISCONNECT THAT IS ACCESSIBLE AND LOCKABLE BY THE UTILITY.THE DISCONNECT SHALL FOR THEIR PURPOSE L LI w GEC A A BE LOCATED WITHIN 10 FT OF UTILITY METER.DISCONNECT SHALL BE GROUPED IN ACCORDANCE WITH NEC 230.72. IF THE EXISTING MAIN SERVICE PANEL DOES NOT HAVE A I- c.o IV ® 5 VERIFIABLE GROUNDING ELECTRODE,IT IS THE (E)200A MAIN BREAKER DERATED TO(N)175A M CONTRACTOR'S RESPONSIBILITY TO INSTALL A (fl KWHR UTILITY METER ®POINT-OF-CONNECTION IS ON LOAD SIDE OF SERVICE DISCONNECT,IN COMPLIANCE WITH NEC 705.12(D)(2)(3)(B).OUTPUT IS BACKFED THROUGH BREAKER IN SUPPLEMENTAL GROUNDING ELECTRODE. C9 MAIN PANEL. AC SYSTEM GROUNDING ELECTRODE CONDUCTOR(GEC) L/ THEPVBREAKERSHALLNOTBEMARKEDFOR"LINE"AND'LOAD'. 6 SHALL BE A MINIMUM SIZE#8AWG WHEN INSULATED,#6AWG L THE PV BREAKER SHALL BE LOCATED AT THE OPPOSITE END OF THE BUSBAR FROM THE MAIN BREAKER. IF BARE WIRE. EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED CONDUCTOR AND CONDUIT SCHEDULE W/ELECTRICAL CALCULATIONS ACCORDING TO NEC ARTICLE 690.45,AND BE A MINIMUM OF CURRENT-CARRYING 7 TYPICAL CONDUCTOR CONDUIT! CONDUCTORS IN CONDUIT I OCPD EGC TEMP.CORR. FILL CONi. MAX.CURRENT BASE DEBATED TERM. AMP.@TERM. #10AWG WHEN NOT EXPOSED TO DAMAGE,AND#6AWG �� ��.•'•••••'•;�� �� CABLE FACTOR FACTOR CURRENT (125%) AMP. AMP. TEMP.RATING TEMP.RATING Q0•. .�/� CABLE SHALL BE USED WHEN EXPOSED TO DAMAGE 1 1 B AWG THWN-2, 0.75"DIA PVC-40 3 N/A 10 AWG THWN2, 0.71(56-C) 1.0 33A 41.25A 75A 53.25A 75"C 65A COPPER COPPERGROUNDING AND BONDING CONDUCTORS,IF INSULATED, - :� O o• 8 AWG THWN-2, 10 AWG THWN-2, " C:Z ON .-•�~ 2 1 COPPER 0.75'DIA PVC40 3 45A CAPPER 0.96(34°C) 1.0 33A 41.25A 55A 52.8A 75°C 50A 8 SHALL BE COLOR CODED GREEN,OR MARKED GREEN IF = #4AWG OR LARGER :2• ' O SINGLE-LINE DIAGRAM PROJECT ID: 149743 DATE: 11/19/20 CREATED BY: SDT CHECKED BY: REVISIONS PV-3 SINGLE-LINE DIAGRAM SCALE: NTS PV-3 SW1 -DISCONNECT 1 EACH DISCONNECTING MEANS FOR 2 POINT-OF-INTERCONNECTION OR AT MAIN SERVICE DISCONNECT(MSP) LABELING NOTES P-149743 (EATON DG222URB PHOTOVOLTAIC EQUIPMENT(SW1) O 1 ALL PLAQUES AND SIGNAGE REQUIRED BY 2014 NEC O O O I AND 2015 NFPA 1 WILL BE INSTALLED AS REQUIRED. I WARNING I I CAUTION I LABELS,WARNING(S)AND MARKING SHALL COMPLY ELECTRIC SHOCK HAZARD.DO NOT TOUCH POWER TO THIS BUILDING IS ALSO FROM ROOF MOUNTED SOLAR ARRAY WITH SAFETY DISCONNECTS WITH ANSI Z535.4,WHICH REQUIRES THAT DANGER, MSP-MAIN SERVICE PANEL TERMINALS TERMINALS ON BOTH LINE AND AS SHOWN WARNING,AND CAUTION SIGNS USED THE STANDARD O _ _ O O LOAD SIDES MAYBE ENERGIZED IN THE OPEN 2 HEADER COLORS,HEADER TEXT,AND SAFETY ALERT / POSITION SYMBOL ON EACH LABEL.THE ANSI STANDARD REQUIRES A HEADING THAT IS AT LEAST 50%TALLER NEC 690.17(E) THAN THE BODY TEXT,IN ACCORDANCE WITH NEC 110.21(B). LJJ 0 AC SOLAR DISCONNECT(SW1,CBI IN MSP) A PERMANENT PLAQUE OR DIRECTORY SHALL BE I INSTALLED PROVIDING THE LOCATION OF THE SERVICE (n J SOLAR ARRAY 3 DISCONNECTING MEANS AND THE PHOTOVOLTAIC > SYSTEM DISCONNECTING MEANS IF NOT IN THE SAME LOCATION IN ACCORDANCE WITH NEC 690.56(B). 0g LABEL(S)WITH MARKING,"PHOTOVOLTAIC SYSTEM • 4 EQUIPPED WITH RAPID SHUTDOWN,"SHALL BE LOCATED AT POINT-OF-INTERCONNECTION OR AT MAIN SERVICE DISCONNECT THE LABEL SHALL HAVE 3/8"TALL NEC 690.13(B) LETTERS AND BE REFLECTIVE WITH WHITE TEXT ON A O 3 OISCONNEC RED BACKGROUND 0j OAC DISCONNECT(SW1,CB1 IN MSP) MAIN PANEL AC COMBINER Q _ C/)O > 0 INSTALLED BY EFFICIENT HOME SERVICES • 8447788810 H � cfl N NEC 690.54 NEC 690.56(B) AND NEC 705.10 ANY AC ELECTRICAL PANEL THAT IS FED BY (. \� SOLAR BREAKER(MSP) SEE NOTE NO.4(MSP) �7 BOTH THE UTILITY AND THE PHOTOVOLTAIC SYSTEM(MSP) Ii������ • • • • . • -- . I WARNING I ,•�'�A�•• •••�:��y�•, - • DUAL POWER SOURCE.SECOND SOURCE ISIIIi O�� '•.�0 iA PHOTOVOLTAIC SYSTEM. . ~: u�= ujs. NEC 690.12 AND NEC 690.56(C) NEC 705.12(D)(3) �• # +' ' ��d OSOLAR BREAKER(MSP) �'�s3•'•• ••..••••'���h� I WARNING I INVERTER OUTPUT CONNECTION DO NOT I SAFETY LABELS RELOCATE THIS OVERCURRENT DEVICE. DOC ID:149743-184646-1 NEC 705.12(D)(2)(3)(B) DATE:11/19/20 CREATOR: REVIEWER: REVISIONS PV-4 ROOF PROPERTIES P-149743 ROOF MATERIAL COMPOSITION SHINGLE(1 LAYER) SLOPE 6/12(26.6°) MEAN ROOF HEIGHT 16.9FT DECK SHEATHING 15/32"OSB CONSTRUCTION RAFTERS(2X4'S),241N OC RIDGE I MODULE MECHANICAL PROPERTIES I I I I I W p MODEL APTOS SOLAR DNA-120 325 I I I 1 > DIMENSIONS(AREA) 66.31N X 39.4IN X 1.41N(18.2 SQ FT) I I w >- m v- WEIGHT 41.9LB 7 - I I I 4 U M MOUNTING SYSTEM PROPERTIES I I Z RAIL MODEL QUICK MOUNT PV QRAIL QMR-RL ANCHOR MODEL QUICK MOUNT PV QMLM(FLASHED), RIDGE J LOIN AIR GAP I ( I 3.5 INCH EMBEDMENT INTO RAFTERS 1 I J FASTENING METHOD WITH(1)5/161N DIA.FASTENER I I Q LLJ MAX.ALLOW.RAIL SPAN 72.01N(ZONE 1) i Y (n 48.0IN(ZONES 2 AND 3) < p J MAX.MOUNT SPACING 72.0IN(ZONE 1) I I I I I i I i I I I 1 I W W I I I I 48.0IN(ZONES 2 AND 3) I I I I I I I I I I I 1 I I I 1 MAX.ALLOW. 23.81N(ZONE 1) CANTILEVER 15.81N(ZONES 2 AND 3) EAVE GROUNDING AND INTEGRAL GROUNDING CERTIFIED TO UL 2703 REQUIREMENTS BONDING DEAD LOAD CALCULATIONS LIWIND ZONE I WIND ZONE II WIND ZONE III iii, LOAD QTY LBS TOTAL LBS ���`�pS •�1� ��,� .`ao�;:•'' • '••.;Lim. MODULES 33 41.9 1382.3 DISTANCE a IS EQUAL TO 10%OF THE BUILDING'S LEAST HORIZONTAL DIMENSION OR 40%OF THE MEAN ROOF HEIGHT,WHICHEVER IS SMALLER,BUT NOT LESS THAN 4%OF THE LEAST HORIZONTAL DIMENSION OR 3 FEET(ACSE 7- • 10).THESE SETBACKS ARE APPLIED TO THE BUILDING FOOTPRINT AND PROJECTED TO THE PLANES OF ROOF CORNERS,RAKES,HIPS,EAVES,MANSARDS,AND RIDGES OF ROOF FACES. • 2' MICROINVERTERS 33 1.1 35.6 ) � ;h LINEAR FEET OF RAIL 226 FT 0.5 113.2 a=MAX(MIN(0.4*MEAN ROOF HEIGHT,0.1*LEAST HORIZONTAL DIMENSION), 0.04*LEAST HORIZONTAL DIMENSION,3 FT) _ w:w 5.3 FT=MAX(MIN(0.4*16.9 FT,0.1*52.7 FT), 0.04°52.7 FT,3 FT) = '% o O'O ANCHORS 54 1.0 55.1 • MISC.HARDWARE 26.1 26.1 ATTACHMENT PLAN (ORTHOGONAL PROJECTION TOTAL ARRAY WEIGHT 1612.3 LBS PV 5 SCALE:3/32"' Ii AREA NAME QTY 1 SQFT TOTAL SQFT MODULES 33 18.2 600.6 ATTACHMENT POINT LOAD(1612.3 LBS/54 ATTACHMENTS) 29.9 LBS PLAN DIST.LOAD(1612.3 LBS/600.6 SQFT) 2.68 PSF DOC ID:149743-184646-1 DATE:11/19/20 NOTES CREATOR: RAFTER LOCATIONS ARE APPROXIMATE.ACTUAL REVIEWER: 1 LOCATIONS MAY DIFFER AND CONTRACTOR MAY NEED TO ADJUST MOUNT LOCATIONS.IN NO CASE SHALL THE REVISIONS MOUNT SPACING EXCEED"MAX.MOUNT SPACING" The existing structure will be adequate for supporting the additional PV dead load and wind loads. PV-5 MOUNTING SYSTEM NOTES P-149743 FLASHING SHALL BE APPLIED IN ACCORDANCE WITH MANUFACTURERS'INSTRUCTIONS. IF THERE IS ANY CONFLICT BETWEEN WHAT IS DEPICTED HERE AND INSTRUCTIONS 2 PROVIDED BY A MANUFACTURER,THE MANUFACTURER'S INSTRUCTIONS SHALL SUPERCEDE. RAIL CLAMPING ZONE QMPVUNIVERSAL--, /- -\ c m PV MODULE \/ ROOF FRAMING �� .r QMPV QRAIL LIGHT W z J PV MODULE r�C_ \ `• % QMPV L-MOUNT O -\ + C J - c COMP.SHINGLE \I 0 W + ROOFING + SLIDE FLASHING > >- �� ' ✓��� UNDER THE 3RD J = B j ,� COURSE OF SHINGLES 0 �- \_/ 1 �, r w V J w PV-6 ROOF UNDERLAYMENT \`/ ' ROOF FRAMING H M N ROOF DECKING • c. LAG/STRUCTURAL SCREWS EMBEDDED INTO ROOF FRAMING ( A RACKING ELEVATION (TRANSVERSE VIEW) C ATTACHMENT DETAIL (TRANSVERSE VIEW) SCALE: NTS PV-6 SCALE: NTS ��! " i, ' 7 PV MODULE = w��+' �TJ F �' ' QMPV UNIVERSAL MID CLAMP QMPV UNIVERSAL- ' j j-PV MODULE ' END CLAMP /- `�/ j �. QMPV QRAIL LIGHT �. ' �� 1I f 1 ; +` - ��j�*.....p� COMP.SHINGLE 1 J ROOFING QMPV L-MOUNT - -- - �� - QMPV L ' (QMLM/QMLM-ST) - -- - -=--- QRAIL j- LIGHT �,� --- DETAILS I" ', .I ROOF DECKING I COMP.SHINGLE / c � DOC ID:149743-184646-1 ROOFING �\ ,"/ // � /%INSTALL FLASHING DATE:11/19/20 ROOF FRAMING SPACING ATTACHMENT SPAN ROOF UNDERLAYMENT j CREATOR: -ROOF FRAMING ROOF DECKING- , / _LAG/STRUCTURAL SCREWS REVIEWER: ROOF FRAMING= EMBEDDED INTO ROOF REVISIONS FRAMING B RACKING ELEVATION (LONGITUDINAL VIEW) D ATTACHMENT DETAIL (LONGITUDINAL VIEW } P�-�•' SCALE: NTS PV-6 SCALE: NTS PV-6 O GENERAL NOTES P-149743 ROOF ACCESS POINTS SHALL BE DEFINED AS AREAS WHERE FIRE DEPARTMENT LADDERS ARE NOT PLACED OVER OPENINGS(WINDOWS OR DOORS),ARE LOCATED AT STRONG POINTS OF BUILDING CONSTRUCTION,AND ARE IN LOCATIONS WHERE THEY WILL NOT CONFLICT WITH OVERHEAD OBSTRUCTIONS(TREE LIMBS,WIRES, OR SIGNS).(NFPA 111.12.2.2.1.3) PHOTOVOLTAIC MODULES SHALL BE LOCATED IN A MANNER THAT PROVIDES A 3 FT WIDE CLEAR ACCESS PATHWAY FROM THE EAVE TO THE RIDGE OF EACH 2 ROOF SLOPE WHERE THE PHOTOVOLTAIC MODULES WO ARE LOCATED.THE ACCESS PATHWAY SHALL BE F- LOCATED AT A STRUCTURALLY STRONG LOCATION OF Cl) THE BUILDING,SUCH AS A BEARING WALL,EXCEPT >- cu WHERE ADJOINING ROOF PLANES PROVIDE A 3 FT WIDE Cn = Lo CLEAR ACCESS PATHWAY.(NFPA 111.12.2.2.2.1.1) M w U ch 3 PHOTOVOLTAIC MODULES SHALL BE LOCATED NO LESS W Z THAN 3 FT BELOW THE RIDGE.(NFPA 1 11.12.2.2.2.2) LJ L 0 0 o3 1O 1.5 FT.WIDE FIRE ACCESS PATHWAY O J 2 PV MODULES INSTALLED ON ROOF WITH QUICK MOUNT Q _ ' PV QRAIL MOUNTING SYSTEM.THE MOUNTING SYSTEM J 2O IS UL 1703 CLASS A FIRE RATED ON A 6/12 SLOPED 0 W ROOF WHEN INSTALLED WITH TYPE 1 OR 2 MODULES. Cl) > THE APTOS SOLAR DNA-120 325 IS TYPE 1. Q 3.0 FT.WIDE SMOKE VENTILATION SETBACK,PER NFPA W C!) W S 111.12.2.2.2.2 F- co N O 3.0 FT.WIDE FIRE ACCESS PATHWAY,PER NFPA 1 Q' 5 4 11.12.2.2.2.1.1 $ 7 6 O5 ROOF ACCESS POINT o 3.0 FT.WIDE SMOKE-VENTILATION SETBACK,PER NFPA 6 111.12.2.2.2.2 O 3.0 FT.WIDE FIRE ACCESS PATHWAY,PER NFPA 1 ,�++"' ►r,,� 9 11.12.2.2.2.1.1 ,,�,���E*••. •,y��y��+ OB ROOF ACCESS POINT O9 ROADWAY Q' Q J. lJJ TOTAL PLAN VIEW ARRAY AREA IS 548.3 SQ.FT,WHICH W o ;z` 10 REPRESENTS 14.7%OF TOTAL PLAN VIEW ROOF AREA .yy;' O (3729.3 SQ.FT) : !y•. h`': <Q, THIS SYSTEM UTILIZES MICROINVERTERS.THERE ARE '�����lic '•• 11 NO DC CIRCUITS OUTSIDE OF THE ARRAY PERIMETER ',,, r OR INSIDE THE BUILDING. CABLES,WHEN RUN ARRAYS,SHALL BE 12 ENCLOSED N CONDUIT FIRE SAFETY EIIFIRE SAFETY PLAN PLAN SCALE: 1"=20' DOC ID:149743-184646-1 DATE:11/19/20 CREATOR: REVIEWER: REVISIONS PV-7 UEL RU/20�'�. �5•� CENSF• No 88991 •: - *• :3t - -0 STATE OF ;•�; .DNA- 120 ALL - BLACK DESIGN 330W 1325W 1320W BLACK FRAME, BLACK BACKSHEET aptOSTM HIGH EFFICIENCY HALF-CUT CELL PANEL solar technology iL• 1 ' _ GNA-120-MF23.320W 0NA-12-MF23-325W DNA-120-MF23.330W fI STCrated output Pmpp 320 325 330 w. s1••w Module Efficiency 18.96% 19.25% 19.54% MAWMN..•00NMM va • Open Circuit Voltage V.(V) 39.92 40.10 40.27 a bm..FM.•»x•. t 6] Short Circuit Current I.°(A) 10.35 10.43 10.51 ,cw.r„W.•oo wr• 11•• Rated Voltage Vinmp(V) 32.51 32.71 32.91 .wwm•.»°wS1 n.w Rated Current Immp(A) 9.84 9.93 10.02 2 — - Standard Test Conditions for front-face of panel: 1000 W/m 2,25°C,measurement uncertainty s3% to » » .• �• Temperature Coefficients Pmpp -0.40%/°C • Temperature Coefficients Is. +0.046%fC Cell Type MonocrystaIline Temperature Coefficients V. -0.306%I°C Glass Low Iron,Tempered kA9 • Normal Operating Cell Temperature(NOCT) 45°C Frame Anodized Aluminum Alloy - • • 1 • Junction Box IP67 Maximum Series Fuse 20A Dimension 1684 x 1002 x 35mm • -• - • •• ••• )12AWG, Maximum System Voltage Output Cable 39.37io 1J000rlun Y 9 1,500 VDC(UL&IEC) ( ) • • - - • Maximum Load Capacity(Per 5,400PA Snow Load Weight 41.91bs.(19kg) • UL1703) 175mph Wind Rating conditionsFire Performance Class Class C/Type 1 Cable Length 1200mm X11 '. • •.• t • 1 1 • Number of Modules per Pallet 30 • •- • • • Number of Pallets per 40ft HQ 26 • Container Pallet Dimensions(mm) 1720X 1140 X 1140 t ) Pallet weight(kg) 620 l��/) • • ' • Container weight(kg) 16120 • • E E E m 1 ' • Our 1 • • • r LISTED 31400e 1002mm i 35mm 952mm • • • DNA-120-MF23-XXXW • • 11.333. Aptos Solar Technology reserves the right to make specification changes without notice RESIDENTIAL I COMMERCIAL % trrerrifi �\CEN •O'- p . No 88991 o . STATE OF = Enphase IQ 7 and IQ 7+ Microinverters Enphase Microinverters INPUT DATA(DC) IQ7-60-2-US/IQ7-60-B-US IQ7PLUS-72-2-US/IQ7PLUS-72-B-US Region:- Commonly used module pairings' 235W-350W+ 235W235W-440W+ Module compatibility 60-cell PV modules only 60-cell and 72-cell PV modules Maximum input DC voltage 48 V 60 V Peak power tracking voltage 27 V-37 V 27 V-45 V Operating range 16 V-48 V 16 V-60 V Min/Max start voltage 22 V/48 V 22 V/60 V Max DC short circuit current(module Isc) 15 A 15 A Enphase The high-powered smart grid-ready Overvoltage class DC port 11 II Enphase IQ 7 Micro"and Enphase IQ 7+Micro'" DC port backfeed current 0 A 0 A Q 7 a n d I Q 7 y p PV array configuration 1 x 1 ungrounded array;No additional DC side protection required; ♦ dramaticall sim lify the installation p rocess while AC side protection requires max 20A per branch circuit achieving the highest system efficiency. OUTPUT DATA(AC) IQ 7 Microinverter IQ 7+Microinverter Microinverters Peak output power 250 VA 295 VA Part of the Enphase IQ System,the IQ 7 and Maximum continuous output power 240 VA 290 VA IQ 7+Microinverters integrate with the Enphase Nominal(L-L)voltage/range2 240 V/ 208 V/ 240 V/ 208V/ g P 211-264 V 183-229V 211-264 V 183-229 V IQ Envoy'",Enphase IQ Battery-,and the Enphase Maximum continuous output current 1.0 A(240 V) 1.15A(208v) 1.21 A(240V) 1.39A(208V) Noz Enlighten'"monitoring and analysis software. Extendeal d uency 47-6 47-6 Extended frequency range 47-68 Hz 47-68 Hz IQ Series Microinverters extend the reliability AC short circuit fault current over 3 cycles 5.8 Arms 5.8 Arms Maximum units per 20 A(L-L)branch circuit' 16(240 VAC) 13(208 VAC) 13(240 VAC) 11(208 VAC) standards set forth by previous generations and Overvoltage class AC port III III undergo over a million hours of power-on testing, AC port backfeed current 0 A 0 A Power factor setting 1.0 enabling Enphase to provide an industry-leading 1.0 0 Power factor(adjustable) 0-85 leading...0.85 lagging 0.85 leading...0.85 lagging warranty of up t0 25 years. EFFICIENCY @240 V @208 V @240 V @208 V Peak efficiency 97.6% 97.6% 97.5% 97.3% CEC weighted efficiency 97.0% 97.0% 97.0% 97.0% MECHANICAL DATA Ambient temperature range -40°C to+65°C Relative humidity range 4%to 100%(condensing) Easy to Install Connector type(IQ7-60-2-US&IQ7PLUS-72-2-US) MC4(or Amphenol H4 UTX with additional Q-DCC-5 adapter) Connectortype(IQ7-60-B-US&IQ7PLUS-72-B-US) Friends PV2(MC4 intermateable). • Lightweight and simple Adaptors for modules with MC4 or UTX connectors: • Faster installation with improved,lighter two-wire cabling -PV2 to MC4:order ECA-S20-S22 PV2 to UTX:order ECA-S20-S25 • Built-in rapid shutdown compliant(NEC 2014&2017) Dimensions(WxHxD) 212 mm x 175 mm x 30.2 mm(without bracket) Weight 1.08 kg(2.38 Ibs) Productive and Reliable Cooling Natural convection-No fans Approved for wet locations Yes • Optimized for high powered 60-cell and 72-cell*modules Pollution degree PD3 • More than a million hours of testing Enclosure Class 11 double-insulated,corrosion resistant polymeric enclosure • Class 11 double-insulated enclosure Environmental category/UV exposure rating NEMA Type 6/outdoor • UL listed FEATURES Communication Power Line Communication(PLC) Monitoring Enlighten Manager and MyEnlighten monitoring options. Smart Grid Ready Both options require installation of an Enphase IQ Envoy. Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load-break • Complies with advanced grid support,voltage and disconnect required by NEC 690. frequency ride-through requirements Compliance CA Rule 21(UL 1741-SA) • Remotely updates to respond to changing UL 62109-1,UL1741/lEEE1547,FCC Part 15 Class B, ICES-0003 Class B, grid requirements CAN/CSA-C22.2 NO.107.1-01 This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and • Configurable for varying grid profiles NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems,for AC • Meets CA Rule 21 (UL 1741-SA) and DC conductors,when installed according manufacturer's instructions. *The 107+Micro is required to support 72-cell modules. 1.No enforced DC/AC ratio.See the compatibility calculator at httos://enphase com/en-us/suonort/module-com atip bility. 2.Nominal voltage range can be extended beyond nominal if required by the utility. 3.Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. EN PHASE. To learn more about Enphase offerings,visit enphase.com EN PHASE. To learn more about Enphase offerings,visit enphase.com �./ Enphase Energy, i QRailTM— Fully Integrated Mounting and Racking System Fast, Simple Installation: It Just Clicks The QRail Series is a strong and versatile solar array mounting system that provides unrivaled benefits to solar QCIickTechnologym designers and installers. Combined with Quick Mount PV's industry-leading waterproof mounts,QRail offers a The universal mid and end clamps use patented QClick complete racking solution for mounting solar modules on any roof, technology to simply"click" into the rail channel and remain upright, ready to accept the module.The ri Easily design array configurations with the QDesign software pre-assembled clamps fit virtually all module frames and application.Generate complete engineering reports and calculate require no extra hardware,eliminating pre-loading and rt a precise bill of materials for all the mounting, racking and reducing installation time. accessories needed for a complete solar array. UNIVERSAL END CLAMP UNIVERSAL BONDED MID CLAMP '•�` 2 clamps for modules from 2 clamps for modules from 1 2 3 30-45mm or 38-50mm thick 30-45mm or 38-50mm thick click! Comprehensive, One-Source Solution Installing is as easy as 1-2-3(�(�n QRail,togetherwith Quick Mount PV's waterproof mounting products, provides the benefit of a single-sourced, QSplkce"Technology seamlessly integrated rooftop installation that works with all roof types—composition/asphalt shingles, QRail's innovative internal QSplice installs in seconds, requiring no flat or curved tile, metal shingle,shake,slate and low slope roofs.The QRail system also works with any roof tools or screws. Simply insert QSplice into the rail and slide the other rail on to create a fully structural, bonded splice.An external splice is attachment system for maximum flexibility. QSPLICE also available. Superior Strength and Versatility 1 2 3 QRail is engineered for optimal structural performance.The system is certified to UL 2703,fully code compliant and backed by a 25-year EEAvr Installs in seconds—no tools or hardware required warranty.QRail is available in Light,Standard and Heavy versions to match all geographic locations. QRail is compatible with virtually all STAHUARU Fully Integrated Electrical Bonding LIGHT modules and works on a wide range of pitched roof surfaces. Modules QRails come in two lengths— The QRail system provides an integrated electrical bonding path,ensuring that all exposed metal parts and can be mounted in portrait or landscape orientation in standard or the solar module frames are electrically connected.All electrical bonds are created when the compone�Qt$1 168 inches(14 ft)and 208 inches(17.3 ft) ,, shared-rail configurations. Mill and Black Finish installed and tightened down. �.�'`pNu�.../<,�''•, ��y..•��_ENSF•.oy No 88991 •'q'� o•'. STATE OF ;•�; %11 1 1 1 1"1,/ ITEM �,..•... .,o NO. I DESCRIPTION QTY. ��5;• ti�cEivsF ;o�;, THIS EDGE TOWARDS ROOF RIDGE 1 FLASHING, ROUNDED CORNERS, 9" X 12" X .040", .438" HOLE, 5052, 1 '*:' No 8s •��* MILL 2 L-FOOT, 2" X 3.30" FOR .438" O.D. FASTENER, 2-1/16" SLOT, 6061- 1 =A;• STATE OF •:�� T6/6005A-T61 , MILL 3 WASHER, SEALING, 5/16" ID X 3/4" OD, EPDM BONDED SS 1 4 i LAG SCREW, HEX HEAD, 5/16" x 4", 18-8 SS 1 *5 STRUCTURAL SCREW, QMPV, T-30 HEX WASHER HEAD, 5/16" X 4-1/2", 1 18-8SS 12.00 *5 4 � I / 4.20 ) /�* STRUCTURAL 3.00 3 SCREW AVAILABLE ON QMLM-ST I- 4.50 VERSIONS ONLY 2 9.00 2.00 0 .397 1 .00 2.09 3.30 .90 ) 1 AVAILABLE IN MILL, AND BLACK FINISHES ph � 9 Mount PV; .040 j-T- TITLE: ( 3.54 ) 4.04 QMLM & QMLM-ST: L-MOUNT, ( 2.50 ) 2.75 2-1 /16" SLOT QMLM QMLM-ST UNLESS OTHERWISE SPECIFIED: SIZE DRAWN BY: RAD REV DIMENSIONS ARE IN INCHES TOLERANCES: A DATE: 7/16/2018 FRACTIONAL± 1/8 PROPRIETARY AND CONFIDENTIAL DECIMAL ±.19 THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF QUICK MOUNT PV. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE DO NOT SCALE DRAWING TWO PLACE PLACE ACE ACEDECIMAL ±.094 SCALE: 1:4 WEIGHT:1.0723 SHEET 1 OF 1 WRITTEN PERMISSION OF QUICK MOUNT PV IS PROHIBITED. COPYRIGHT©2016 QUICK MOUNT PV 5 4 3 2 1