HomeMy WebLinkAbout20-1240 i City of Zephyrhills PE- MIT NUMBER 5335 Eighth Street Zephyrhills, FL 33542 ELCMISC-001240-2020 Phone: (813)780-0020 Issue Date: 01/06/2021 Fax: (813)780-0021 Permit Type: Electric Service Replacement/Misc Property Number Street Address 11 04 26 21 0070 00100 0040 6402 Silverado Ranch Boulevard Owner Information Permit Information Contractor Information Name: FRANCIS IRVING JR&ROSEMARIE Permit Type:Electric Service Replacement/M Contractor: EFFICIENT HOME MINNIX Class of Work:Add/Alter Residential SERVICES OF FLORIDA LLC Address: 6402 Silverado Ranch Boulevard Building Valuation:$0.00 ZEPHYRHILLS,FL 33541 Electrical Valuation:$18,076.00 Phone: (813)395-1581 Mechanical Valuation: Plumbing Valuation: ` Total Valuation:$18,076.00 s�� Total Fees: 5 Amount Paid::$1$195.57 Date Paid:1/6/2021 8:48:24AM Project Description INSTALLATION ROOF MOUNT PHOTOVOLTIC SOLAR Application Fees Electrical Plan Review Fee $65.19 Electrical Permit Fee $130.38 REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each subsequent reinspection. Notice: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permit required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications add fee Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. C T TO SIGN TURE PE IT OFFICE PERMI EX S N 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department Date Received i Z ^ S Phone Contact for Permitting ( 844 778 _ 8810 Owners Name MINNIX,FRANCIS Owner Phone Number (813)395-1581 Owners Address 1402 SILVERADO RANCH BOULEVARD ZEPHYRHILLS Owner Phone Number Fee Simple Titleholder Name I Owner Phone Number Fee Simple Titleholder Address JOB ADDRESS 6402 SILVERADO RANCH BOULEVARD ZEPHYRHILLS FL 33541 LOT# SUBDIVISION SILVERADO RANCH PARCEL ID#1 04-26-21-0070-00100-0040 (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED a NEW CONSTR e ADD/ALT = SIGN Q 0 DEMOLISH INSTALL REPAIR PROPOSED USE XD SFR 0 COMM = OTHER TYPE OF CONSTRUCTION = BLOCK 0 FRAME = STEEL = DESCRIPTION OF WORK INSTALLING A ROOF MOUNTED SOLAR PHOTOVOLTSIC SYSTEM BUILDING SIZE SQ FOOTAGE HEIGHT =BUILDING $ VALUATION OF TOTAL CONSTRUCTION 18076 =X ELECTRICAL $ 18076 AMP SERVICE 150 PROGRESS ENERGY Q W.R.E.C. / =PLUMBING $ ( 1/� / MECHANICAL $ VALUATION ONICAL INSTALLATION v =GAS = ROOFING 0 SPECIALTY = OTHER FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES NO\& BUILDER COMPANY SIGNATURE REGISTERED Y/N FEE CURREN Y/N Address License# ELECTRICIAN r COMPANY EFFICIENT HOME SERVICES OF FLORIDA SIGNATURE REGISTERED Y/N FEE CURREN Y/N Addr s 9 6 N ERNA ON AL N ST TERSBURG FL 33716 License# EC13008759 PLUMBER COMPANY SIGNATURE REGISTERED Y/N FEECURREN Y/N Address License# MECHANICAL COMPANY SIGNATURE REGISTERED Y/N FEE CURREN Y/N Address License# OTHER COMPANY SIGNATURE REGISTERED Y/N FEE CURREN Y/N Address License# ■ttttttttttt■t■ttttttttitttttttttt■tittttttttttttittttt,tttttttttttt9 RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of.Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date.Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster,Site Work Permit for subdivisions/large projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Fortes.R-O-W Permit for new construction. Minimum ten(10)working days after submittal date.Required omite,Construction Plans,Stornwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. —PROPERTY SURVEY required for all NEW construction. Directions: Fill out application completely. Owner&Contractor sign back of application,notarized If over$2500,a Notice of Commencement is required.(A/C upgrades over$7600) Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage) Driveways-Not over Counter if on public roadways..needs ROW 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department NOTICE OF DEED RESTRICTIONS:The undersigned understands that this permit may be subject to"deed"restrictions"which may be more restrictive than County regulations.The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES:If the owner has hired a contractor or contractors to undertake work,they may be required to be licensed in accordance with state and local regulations.If the contractor is not licensed as required by law,both the owner and contractor may be cited for a misdemeanor violation under state law.If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work,they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847-8009. Furthermore,If the owner has hired a contractor or contractors,he is advised to have the contractor(s)sign portions of the"contractor Block"of this application for which they will be responsible.If you,as the owner sign as the contractor,that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES:The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings,change of use in existing buildings,or expansion of existing buildings,as specified in Pasco County Ordinance number 89-07 and 90-07,as amended.The undersigned also understands,that such fees,as may be due,will be identified at the time of permitting.It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a"certificate of occupancy"or final power release.If the project does not involve a certificate of occupancy or final power release,the fees must be paid prior to permit issuance.Furthermore,if Pasco County Water/Sewer Impact fees are due,they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713,Florida Statutes,as amended):If valuation of work is$2,500.00 or more,I certify that I,the applicant, have been provided with a copy of the"Florida Construction Lien Law—Homeowner's Protection Guide"prepared by the Florida Department of Agriculture and Consumer Affairs.If the applicant is someone other than the"owner",I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner"prior to commencement CONTRACTOR'S/OWNER'S AFFIDAVIT:I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction,zoning and land development.Application is hereby made to obtain a permit to do work and installation as indicated.I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction,County and City codes,zoning regulations,and land development regulations in the jurisdiction.I also certify that I understand that the regulations of other government agencies may apply to the intended work,and that it is my responsibility to identify what actions I must take to be in compliance.Such agencies include but are not limited to: - Department of Environmental Protection-Cypress Bayheads, Wetland Areas and,Environmentally Sensitive Lands,Water/Wastewater Treatment. Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. Army Corps of Engineers-Seawalls,Docks,Navigable Waterways. Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. US Environmental Protection Agency-Asbestos abatement. Federal Aviation Authority-Runways. I understand that the following restrictions apply to the use of fill: Use of fill is not allowed in Flood Zone"V"unless expressly permitted. If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a .compensating volume"will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. If the fill material is to be used in Flood Zone"A" in connection with a permitted building using stem wall construction,I certify that fill will be used only to fill the area within the stem wall. If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties,the owner may be cited for violating the conditions of the building permit issued under the attached permit application,for lots less than one(1) acre which are elevated by fill;an engineered drainage plan is required. If I am the AGENT FOR THE OWNER,I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction.I understand that a separate permit may be required for electrical work,plumbing,signs,wells,pools,air conditioning,gas,or other installations not specifically included in the application.A permit issued shall be construed to be a license to proceed with the work and not as authority to violate,cancel,alter,or set aside any provisions of the technical codes,nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans,construction or violations of any codes.Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance,or if work authorized by the permit is suspended or abandoned for a period of six(6)months after the time the work is commenced.An extension may be requested,in writing,from the Building Official for a period not to exceed ninety(90)days and will demonstrate justifiable cause for the extension.If work ceases for ninety(90)consecutive days,the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY.IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER QR AN ATTORNEY BEFORE RECORDING YO TICE OF CQMMFNCFMFNT_ FLORIDA JURAT(F.S.117.03) OW14ER OR AGENT CONTRACTOR �Cyvfsbv swo rRaKleMqejs 1 d swo o r I e i�byois/r soAa y know or haoduced o is a personall now to me or hasgiave produced 1•• as—identification. _ Identificatio JA h lic V Public. Commission No. ommission No. Name of Notary typed,printed or stamped Name of Notary typed,printed or stamped Notery.PZigttate of Florida p`y Notary Public State of Florida utledge -�Fn GG 249046 , Danielle is Rutledge 0 22 � My Commission GG 249046 ®p n Expires 06/15/2022 DIRECTORY OF PAGES SCOPE OF WORK P-1 50633 PV-1 PROJECT SUMMARY THIS PROJECT INVOLVES THE INSTALLATION OF A GRID- INTERACTIVE PV SYSTEM.PV MODULES WILL BE MOUNTED USING A PREENGINEERED MOUNTING SYSTEM.THE MODULES EEL PV-2 SITE PLAN WILL BE ELECTRICALLY CONNECTED WITH DC TO AC POWER EELPV 3 SINGLE LINE DIAGRAM INVERTERS AND INTERCONNECTED TO THE LOCAL UTILITY USING MEANS AND METHODS CONSISTENT WITH THE RULES PV-4 SAFETY LABELS ENFORCED BY THE LOCAL UTILITY AND PERMITTING PV-5 ATTACHMENT PLAN JURISDICTION. PV-6 ATTACHMENT DETAILS y THIS DOCUMENT HAS BEEN PREPARED FOR THE PURPOSE OF PV-7 FIRE SAFETY PLAN � DESCRIBING THE DESIGN OF A PROPOSED PV SYSTEM WITH H 0 ENOUGH DETAIL TO DEMONSTRATE COMPLIANCE WITH Cl) > MODULE DATASHEET . APPLICABLE CODES AND REGULATIONS.THE DOCUMENT V- ARRAY WIRING BOX DATASHEET SHALL NOT BE RELIED UPON AS A SUBSTITUTE FOR > CO FOLLOWING MANUFACTURER INSTALLATION INSTRUCTIONS. U M ALL WORK SHALL COMPLY THE SYSTEM SHALL COMPLY WITH ALL MANUFACTURERS WITH PREVAILING LISTING AND INSTALLATION INSTRUCTIONS,AS WELL AS ALL X INVERTER DATASHEET CODES FLORIDA 80ILDINIS CODE, z NATIONAL ELECTRIC CODE, APPLICABLE CODES.NOTHING IN THIS DOCUMENT SHALL BE W Z LL MOUNTING SYSTEM DATASHEET a AND THE CITY OF�E '�11'fHILLS INTERPRETED IN A WAY THAT OVERRIDES THEM. L.L Q MOUNTING SYSTEM ENGINEERING LETTER ORDINANCES CONTRACTOR IS RESPONSIBLE FOR VERIFICATION OF ALL CONDITIONS,DIMENSIONS,AND DETAILS IN THIS DOCUMENT. O3 UL 2703 GROUND AND BONDING CERTIFICATION ANCHOR DATASHEET t �aofP� MapdataO2020 SYSTEM DETAILS PROJECT DETAILS R VIEW DATE I 7112o DESCRIPTION NEW GRID-INTERACTIVE GP SYSTEM 6402 SILVERADO RANCH BLVD, CITY OF ZEPHYRHIL 1 PLOT WITH NO ENERGY STORAGE J = PROPERTY ADDRESS ZEPHYRHILLS,ILLS,FL 33541 US PLAN EXAMINER4iPV 1 SCALE: NTS DC RATING OF SYSTEM 6.17KW 0 ZONING RESIDENTIAL _ AC RATING OF SYSTEM 4.56KW Ui O N AC OUTPUT CURRENT 19.0A USE AND OCCUPANCY ONE-OR TWO-FAMILY DWELLING ® s� 0 CLASSIFICATION GROUP(GROUP R3) (. INVERTER(S) 19 X ENPHASE IQ7-60-2-US UTILITY COMPANY PROGRESS ENERGY FLORIDA INC MODULE APTOS SOLAR DNA-120 325 Richlaad o ELECTRICAL CODE 2014 NEC(NFPA 70) (1)BRANCH OF 9 IQ7-60-2-US FIRE CODE 2015 NFPA 1 it ARRAY WIRING MICROINVERTERS (1)BRANCH OF 10 IQ7-60-2-US OTHER BUILDING 2017 FL BU sss MICROINVERTERS '►+++'►rr� BUILDING CODE CODES ELR(rj�o�,�, y •�� NSF .O,L Zephyrhdls INTERCONNECTION DETAILS CONTRACTOR INFORMATION ® North No 91 POINT OF CONNECTION NEW LOAD SIDE AC CONNECTION *;• COMPANY EFFICIENT HOME SERVICES S PER NEC 705.12(D)(2)(3)(A)AT MSP UTILITY SERVICE 120/240V 1� ADDRESS 9416 INTERNATIONAL CT,ST. .r Upper :4'. PETTERSBURG,FL 32907 _. Hillsborough . SO-•' F MAIN SERVICE PANEL W/200A '•. ORI�- ���.` PHONE NUMBER (844)778-8810 Skydive City/Z Hills 4 Preserve LOCATION BUSBAR 150A MCB CONTRACTOR SIGNATURE SITE DETAILS PROJECT ASHRAE EXTREME LOW 1°C(34°F) SUMMARY Lapel r sa' ASHRAE 2%HIGH 34°C(93°F) This item has been signed and sealed by - DOC ID:150633-185713-1 Reyes Manuel Ruiz Donate, 88991 PE on 12/9/2020 CLIMATE DATA SOURCE ST.PETERSBURG CLEAR(KSPG) using a Digital Signature. Reyes Digitally signed 2 LOCALE WIND SPEED 140 MPH(ASCE7-10) DATE:12/9/20 SCALE: NTS CREATOR: by Reyes Ruiz- PV-1 RISK CATEGORY II REVIEWER: Printed copies of this document are not considered Ruiz- Donate WIND EXPOSURE B signed and sealed and the SHA authentication code Date:2020.12.09 CADGOPO REVISIONS must be verified on any electronic copies. Donate 13:18:15-O5'OO' I REYES M RUIZ DONATE PE# 88991 AN ENGINEER LICENSED PURSUANT TO CHAPTER 471, CERTIFY THAT THE PV ELECTRICAL SYSTEM AND ELECTRICAL COMPONENTS ARE DESIGNED AND APPROVED USING THE STANDARDS CONTAINED IN THE MOST RECENT PV- 1VERSION OF THE FLORIDA BUILDING CODE. GENERAL NOTES P-1 50633 EQUIPMENT LIKELY TO BE WORKED UPON WHILE 1 ENERGIZED SHALL BE INSTALLED IN LOCATIONS THAT SATISFY MINIMUM WORKING CLEARANCES PER NEC 110.26. \- CONTRACTOR SHALL USE ONLY COMPONENTS LISTED 2 BY A NATIONALLY RECOGNIZED TESTING LABORATORY FOR THE INTENDED USE. CONTRACTOR IS RESPONSIBLE FOR FURNISHING ALL 3 EQUIPMENT,CABLES,ADDITIONAL CONDUITS, RACEWAYS,AND OTHER ACCESSORIES NECESSARY UJ FOR A COMPLETE AND OPERATIONAL PV SYSTEM. PROPOSED ROOF-MOUNTED PHOTOVOLTAIC = M (N) W z M ARRAY.5:12(23°)SLOPED ROOF,19 PV MODULES (BLACK FRAME,BLACK BACKSHEET),108°AZIMUTH (N)AC COMBINER,OUTDOOR,OUTPUT CIRCUIT IL O CONDUCTORS SHALL BE RUN IN PVC-40 CONDUIT OVER ROOF NO CLOSER THAN 0.5"ABOVE ROOF ) 0 SURFACE J (N)VISIBLE,LOCKABLE,READILY-ACCESSIBLE AC 0 _ 2 O3 DISCONNECT LOCATED WITHIN 10 FT OF UTILITY METER,OUTDOOR Q W ci S O (E)UTILITY METER,OUTDOOR C/) 0 J O (E)MAIN SERVICE PANEL(MSP),OUTDOOR W C ) W 4 CV N :, O6 ROADWAY 5 '�� No 91 rn 1 SITE PLAN \Fy$J SCALE: 1"=20' SITE PLAN DOC ID:150633-185713-1 DATE:12/9/20 CREATOR: REVIEWER: REVISIONS THIS LAYOUT IS SUBJECT TO CHANGE DUE TO ROOF OBSTRUCTIONS, BUT PANELS ARE NOT ALLOWED TO BE PLACED IN THE FIRE SAFETY PATHWAYS. PV-2 The existing structure will be adequate for supporting the additional PV dead load and wind loads. _____________________ GENERAL ELECTRICAL NOTES P-150633 r - 1jTJ- 11i1TTT ' UTILITY HAS 24-HR UNRESTRICTED ACCESS TO ALL OM MICROINVERTER1 PHOTOVOLTAIC SYSTEM COMPONENTS LOCATED AT THEAPTOS SOLAR DNA-100INVERTERS SERVICE ENTRANCE. MODULES CONFORM TOAND ARE LISTED UNDER UL1703.REF. QTY. MAKEANDMODEL AC VOLTAGE GROUND RATED POWER MAX OUTPUT CURRENT MAX INPUT CURRENT MAX INPUT VOLTAGE CEC WEIG aD E FFICIENCY 11-19 19 ENPHASEIQ7-b0-2-US 2aov UNGROUNDED 24oW 1MA 15.OA 48V CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS a� 10IN 19IN AA DISCONNECTS OCPDS �.. + H + H 7 REF. QTY. MAKE AND MODEL RATED CURRENT MAX RATED VOLTAGE F1 QZ. RATED CURRENT MAX VOLTAGE3 ARSUTICLE 310.10 LIGHT 1(D). NT PER NEC ARTICLE 300.6(C)(1)AND I I SW1 1 EATON DG221URB OR EQUIV. 30A 240VAC CBI 1 30A 240VAC -_ CONDUCTORS EXPOSED TO WET LOCATIONS SHALL BE ff�jLR7562W YSTEM SUMMARY NOTES 4 SUITABLE FOR USE IN WET LOCATIONS PER NEC ARTICLE BRANCH 1 BRANCH 2 ©THE DC AND AC CONNECTORS OF THE ENPHASE IQ7-60-2-US AND ARE LISTED TO MEET REQUIREMENTS AS A DISCONNECT MEANS AS ALLOWED BY NEC 690.15(A).MATING 310.10(C). W ER BRANCH 10 9 CONNECTORS SHALL COMPLY WITH NEC 690.17(E). RENT 10A 9A PUT 2,400W 2,160W THE ENPHASEIQ7-60-2-US NASA CLASS II DOUBLE-INSULATED RATING AND DOES NOT REQUIRE GROUNDING ELECTRODE CONDUCTORS(GEC)OR EQUIPMENT GROUNDING NOTES AC COMBINER ®GROUNDING CONDUCTORS(EGC).THE RATING INCLUDES GROUND FAULT PROTECTION(GFP).TO SUPPORT GFP,USE ONLY PV MODULES EQUIPPED WITH DC CABLES J POWER 6,175W LABELED PV WIRE OR PV CABLE. ALL EQUIPMENT SHALL BE PROPERLY GROUNDED PER THE m L- F1 F2 5,692W 20A 20A C1 POWER RENT 19A ®ENPHASE SYSTEM MEETS REQUIREMENTS FOR PHOTOVOLTAIC RAPID SHUTDOWN SYSTEM(PVRSS),AS PER NEC 690.12. 1 REQUIREMENTS OF NEC ARTICLES 250&690 EROUTPUT 4,56oW PV MODULES SHALL BE GROUNDED TO MOUNTING RAILS POWER OUTPUT 4,`56OW MICROINVERTER BRANCH CIRCUIT CONDUCTORS ARE MANUFACTURED ENPHASE 0 CABLES LISTED FOR USE IN 20A OR LESS CIRCUITS OF ENPHASE IQ MICROINVERTERS. U C'7 r- DISCONNECT THEY ARE ROHS,OIL RESISTANT,AND UV RESISTANT.THEY CONTAIN TWO 12 AWG CONDUCTORS OF TYPE THHN/THWN-2 DRY1WEf AND CERTIFIED TO UL3003 AND UL 9703. USING MODULE LUGS OR RACKING INTEGRATED w z �J L- I SW1 © UNGROUNDED SYSTEM DC CONDUCTORS SHALL BE COLORLODED AS FOLLOWS.DC POSITIVE SHALL BE RED(OR MARKED RED)AND DC NEGATIVE SHALL BE BLACK(OR 2 GROUNDING CLAMPS AS ALLOWED BY LOCAL JURISDICTION. 0 V�-_ I2 ©MARKED BLACK) ALL OTHER EXPOSED METAL PARTS SHALL BE GROUNDEDALL METAL ENCLOSURES,RACEWAYS,CABLES AND EXPOSED NONCURRENT-CARRYING METAL PARTS OF EQUIPMENT SHALL BE GROUNDED TO EARTH AS REQUIRED BY USING UL-LISTED LAY-IN LUGS. QJMAIN SERWCE PANEL NEC 250.4(B)AND PART III OF ARTICLE 250 AND EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED ACCORDING TO NEC 690.45(A).THE GROUNDING ELECTRODES SYSTEM SHALL ADHERE TO NEC 690.47 AND NEC 250.169.THE DC GROUNDING ELECTRODE SHALL BE SIZED ACCORDING TO NEC 250.166 AND INSTALLED IN COMPLIANCEINSTALLER SHALL CONFIRM THAT MOUNTING SYSTEM HA(E124011 #3W BEEN EVALUATED FOR COMPLIANCE WITH UL 270312WABUSBAR WITH NEC 250.64.�150AMAINBREAKER 3GROUNDING AND BONDING"WHEN USED WITH PROPOSED 06 MAX DC VOLTAGE OF PV MODULE IS43.1VAT1°C(1°C-25'C)X-0.123VIC+40AV=43.1V).LOADSI Q ®PV SYSTEM DISCONNECT SHALL BEA VISIBLE KNIFE-BLADE TYPE DISCONNECTTHAT IS ACCESSIBLE AND LOCKABLE BY THE UTILITY.THE DISCONNECT SHALL BE LOCATED PV MODULE. �1 g WITHIN 10 FT OF UTILITY METER.DISCONNECT SHALL BE GROUPED IN ACCORDANCEWITH NEc 230.72. ALL GROUNDING SYSTEM COMPONENTS SHALL BE LISTED uj -4 FOR THEIR PURPOSE LlV®POINT-OF-CONNECTION IS ON LOAD SIDE OF SERVICE DISCONNECT,IN COMPLIANCE WITH NEC 705.12(D)(2)(3)(Aj.OUTPUTI5BACKFEDTHROUGHBREAKER IN MAIN PANEL. IF THE EXISTING MAIN SERVICE PANEL DOES NOT HAVE A �1 _ CV N KWHR UTILITYMEfER VERIFIABLE GROUNDING ELECTRODE,IT IS THE �_ = Co�O CONDUCTOR AND CONDUIT SCHEDULE WIELECTRICAL CALCULATIONS MAX. TERM 5 CONTRACTOR'S RESPONSIBILITY TO INSTALL A --- -� CURREM-CARRYIN TEMP.CORR. IRE . DEBATEDTE AMP.@ TERM. fflOA CODUCTOR CONDUITICABLE GCONDUCTORSIN OCPD ;,, EGC FACTOR FILL FACTORNT C(125°M BASE AMP. AMPMNG TEMp.RATING SUPPLEMENTAL GROUNDING ELECTRODE.CONDUITICABLE ACSYSTEM GROUNDING ELECTRODE CONDUCTOR(GEC) WG THWN-2,COPPER 0.5"DIA PVCAO 30A THWN-2,COPPER 0.71(56C) 1.0 23.75A 40A 26.4A 75°C 35AWGTHWN-2,COPPER 0.5"DIA.PVC-00 30A THWN-2,COPPER 0.96(34°C) 1.0 23.75A 40A 36.4A 75°C 35A 6 SHALL BEA MINIMUM SIZE#8AWG WHEN INSULATED,#6AWG EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZEDACCORDING TO NEC ARTICLE 690.45,AND BE A MINIMUM 4 �� 7 #10AWG WHEN NOT EXPOSED TO DAMAGE,AND#6 AWG OF ��,, ���V'N....... 2. �, .•��CENSF-.O,y SHALL BE USED WHEN EXPOSED TO DAMAGE GROUNDING AND BONDING CONDUCTORS,IF INSULATED, No 88991 9�+ 8 SHALL BE COLOR CODED GREEN,OR MARKED GREEN IF *_ #4AWGORLARGER � o ' TAE OF .� c :�,c� • ;��50R10P•����• Cap SINGLE-LINE DIAGRAM PROJECT ID: 150633 DATE: 12/09/20 CREATED BY: SDT CHECKED BY: REVISIONS SINGLE-LINE DIAGRAM PV 3 SCALE: NTS PV-3 LABELING NOTES P-1 50633 SW1 -DISCONNECT EACH DISCONNECTING MEANS FOR AC SOLAR DISCONNECT(SW1,CB1 IN MSP) AC DISCONNECT(SW1,CB1 IN MSP) ALL PLAQUES AND SIGNAGE REQUIRED BY 2014 NEC EATON DG221URB;) 1 PHOTOVOLTAIC EQUIPMENT(SW1) 1 AND 2015 NFPA 1 WILL BE INSTALLED AS REQUIRED. L@ (1i) ('c> !WARNING I LABELS,WARNING(S)AND MARKING SHALL COMPLY WITH ANSI Z535.4,WHICH REQUIRES THAT DANGER, ELECTRIC SHOCK HAZARD.DO NOT TOUCH WARNING,AND CAUTION SIGNS USED THE STANDARD _ __ MSP-MAIN SERVICE PANEL TERMINALS.TERMINALS ON BOTH LINE AND 2 HEADER COLORS,HEADER TEXT,AND SAFETY ALERT LOAD SIDES MAY BE ENERGIZED IN THE OPEN SYMBOL ON EACH LABEL.THE ANSI STANDARD POSITION. REQUIRES A HEADING THAT IS AT LEAST 50%TALLER La O O NEC 690.17(E) NEC 690.13(8) NEC 690.54 THAN THE BODY TEXT,IN ACCORDANCE WITH NEC 110.21(B). W ANY AC ELECTRICAL PANEL THAT IS FED BY A PERMANENT PLAQUE OR DIRECTORY SHALL BE I--'SEE NOTE NO.4(MSP) O BOTH THE UTILITY AND THE PHOTOVOLTAIC INSTALLED PROVIDING THE LOCATION OF THE SERVICE (J) J SYSTEM(MSP) 3 DISCONNECTING MEANS AND THE PHOTOVOLTAIC >_ m .� { SYSTEM DISCONNECTING MEANS IF NOT IN THE SAME 1 LOCATION IN ACCORDANCE WITH NEC 690.56(B). U M I WARNING ! LABEL(S)WITH MARKING,"PHOTOVOLTAIC SYSTEM iii z • DUAL POWER SOURCE SECOND SOURCE IS EQUIPPED WITH RAPID SHUTDOWN,"SHALL BE LOCATED PHOTOVOLTAIC SYSTEM, 4 AT POINT-OF-INTERCONNECTION OR AT MAIN SERVICE DISCONNECT THE LABEL SHALL HAVE 318"TALL 0U) NEC 705.12 D)(3) LETTERS AND BE REFLECTIVE WITH WHITE TEXT ON A O J NEC 690.12 AND NEC 690.56(C) ( RED BACKGROUND o J Q W O J = Q W C\J N o d- CO 01 DC "IIIirlrr,i �h.•�\CENSF•.O • �9� No 88991 �tn SINE OF �rrrrrillll�� SAFETY LABELS DOC ID:150633-185713-1 DATE:1219120 CREATOR: REVIEWER: REVISIONS Pv-4 ROOF MATERIAL COMPOSITION SHINGLE(1 LAYER) P-150633 ROOF PROPERTIES SLOPE 5/12(22.6°) EH S MEAN ROOF HEIGHT 14.3FT Efficient Home Services RIDGE DECK SHEATHING 15/32"OSB CONSTRUCTION TRUSSES(2X4 TOP-CHORD),241N OC MODULE MECHANICAL PROP ERTIES RIDGE I-- MODEL APTOS SOLAR DNA-120 325 I Cn J w � DIMENSIONS(AREA) 66.31N X 39.41N X 1.41N(18.2 SQ FT) Y C/) = M I I I WEIGHT 41.9LB ± w z RIDGE MOUNTING SYSTEM PROPERTIES C/) RAIL MODEL QUICK MOUNT PV QRAIL QMR-RL �" ANCHOR MODEL QUICK MOUNT PV QMLM(FLASHED), LOIN AIR GAP i J FASTENING METHOD 3.5 INCH EMBEDMENT INTO TRUSSES O W >_ WITH(1)5/161N DIA.FASTENER EAVE C/) J MAX.ALLOW.RAIL SPAN 72.OIN(ZONE 1)48.OIN(ZONES 2 AND 3) C� W 72.01N(ZONE 1) WIND ZONE III W O N MAX.MOUNT SPACING 48.OIN(ZONES 2 AND 3) ❑ WIND ZONE I WIND ZONE II O �, CO MAX.ALLOW. 23.81N(ZONE 1) CANTILEVER 15.81N(ZONES 2 AND 3) GROUNDING AND INTEGRAL GROUNDING CERTIFIED DISTANCE a IS EQUAL TO 10%OF THE BUILDING'S LEAST HORIZONTAL DIMENSION OR 40%OF THE MEAN ROOF HEIGHT,WHICHEVER IS SMALLER,BUT NOT LESS THAN 4%OF THE LEAST HORIZONTAL DIMENSION OR 3 FEET(ACSE 7- BONDIN 10 THESE SETBACKS ARE APPLIED TO THE BUILDING FOOTPRINT AND PROJECTED TO THE PLANES OF ROOF CORNERS,RAKES,HIPS,EAVES,MANSARDS,AND RIDGES OF ROOF FACES. BONDING TO UL 2703 REQUIREMENTS ) a=MAX(MIN(0.4*MEAN ROOF HEIGHT,0.1*LEAST HORIZONTAL DIMENSION), 0.04*LEAST HORIZONTAL DIMENSION,3 FT) DEAD LOAD CALCULATIONS 4.2 FT=MAX(MIN(0.4*14.3 FT,0.1*42.2 FT), 0.04*42.2 FT,3 FT) < t t r uEL RU7I�,�� LOAD QTY LBS TOTAL LBS 1 ATTACHMENT PLAN (ORTHOGONAL PROJECTION; ;�� ;••��cErosF•• MODULES 19 41.9 795.9PV-5 �� No 8f1991 SCALE: 118"= 1' _ *, MICROINVERTERS 19 1.1 20.5 = LINEAR FEET OF RAIL 129 FT 0.5 64.4 °'• cv�� %gyp••.• k.: ANCHORS 36 1.0 36.7 NA MISC.HARDWARE 15.7 15.7 ' TOTAL ARRAY WEIGHT 933.3 LBS AREA NAME QTY SQFT TOTAL SQFT ATTACHMENT MODULES ]1918.2 345.8 PLAN POINT LOAD(933.3 LBS/36 ATTACHMENTS) 25.9 LBS DOC ID:150633-185713-1 DIST.LOAD(933.3 LBS/345.8 SQFT) 2.7 PSF DATE:12/9/20 CREATOR: NOTES REVIEWER: TRUSS LOCATIONS ARE APPROXIMATE.ACTUAL REVISIONS 1 LOCATIONS MAY DIFFER AND CONTRACTOR MAY NEED TO ADJUST MOUNT LOCATIONS.IN NO CASE SHALL THE MOUNT SPACING EXCEED"MAX.MOUNT SPACING" PV-5 MOUNTING SYSTEM NOTES P-I 50633 FLASHING SHALL BE APPLIED IN ACCORDANCE WITH MANUFACTURERS'INSTRUCTIONS. IF THERE IS ANY CONFLICT BETWEEN WHAT IS DEPICTED HERE AND INSTRUCTIONS EH S 2 PROVIDED BY A MANUFACTURER,THE MANUFACTURER'S INSTRUCTIONS SHALL _J Efficient i-f on a Services 1SUPERCEDE. - - RAIL CLAMPING ZONE-\ W 0 J QMPV UNIVERSAL / L!) /- MID CLAMP -\ �• = M / \ _ ch PV MODULE �� U by_\ -�I QMPV QRAIL LIGHT w z J -ROOF FRAMING r LL PVMODULE� _ W COMP.SHINGLE ROOFING ` ' SLIDE FLASHING U) > _ UNDER THE 3RD J 0 COURSE OF SHINGLES W V) LLI B '` � ;� R_ \. ' cal IV ROOF UNDERLAYMENT � / ROOF FRAMING O PV-6 ROOF DECKING-' `. /' Q -- LAG/STRUCTURAL SCREWS EMBEDDED INTO ROOF FRAMING (' RACKING ELEVATION (TRANSVERSE VIEW) C ATTACHMENT DETAIL (TRANSVERSE VIEW V SCALE: NTS P\-,j SCALE: NTS ``�� '• • EL R(��ZOO No8891 •rn D PV MODULE - —QMPV UNIVERSAL MID CLAMP /�PV MODULE / ;0•.• p P;�� )ç QMPV UNIVERSAL � ' � � RI•' •��.`�` END CLAMP N. � - rf - - LI '• S/ QMPV GRAIL LIGHT-. L! i ( I - COMP.SHINGLE ` )-QMPV L-MOUNT ATTACHMENT r' ' (QMLMlQMLM ST) DETAILS ROOFING N :i ;ii:ii . QMPV QRAIL + - - - LIGHT - % ` J-j DOC ID:150633-185713-1 1 ; ROOF DECKING COMP.SHINGLE /ROOFING \ / /'INSTALL FLASHING DATE:12/9/20 \ N ROOFUNDERLAYMENT \\ / CREATOR: - ROOF FRAMING SPACING - � ATTACHMENT SPAN ROOF FRAMING ROOF DECKING \ ^ LAG/STRUCTURAL SCREWS REVIEWER: ROOF FRAMING-' ---'� EMBEDDED INTO ROOF REVISIONS FRAMING RACKING ELEVATION (LONGITUDINAL VIEW D ATTACHMENT DETAIL LONGITUDINAL VIEW PV-6 SCALE: NTS P: -6 SCALE: NTS D\ /-C GENERAL NOTES 1--150633 0ROOF ACCESS POINTS SHALL BE DEFINED AS AREAS WHERE FIRE DEPARTMENT LADDERS ARE NOT PLACED OVER OPENINGS(WINDOWS OR DOORS),ARE LOCATED AT STRONG POINTS OF BUILDING CONSTRUCTION,AND EH S ARE IN LOCATIONS WHERE THEY WILL NOT CONFLICT Efficient Home SrV ices WITH OVERHEAD OBSTRUCTIONS(TREE LIMBS,WIRES, OR SIGNS).(NFPA 1 11.12.2.2.1.3) 2 PHOTOVOLTAIC MODULES SHALL BE LOCATED IN A MANNER THAT PROVIDES A 3 FT WIDE CLEAR ACCESS PATHWAY FROM THE EAVE TO THE RIDGE OF EACH 3 2 ROOF SLOPE WHERE THE PHOTOVOLTAIC MODULES W O ARE LOCATED.THE ACCESS PATHWAY SHALL BE (- LOCATED AT A STRUCTURALLY STRONG LOCATION OF C/) -J THE BUILDING,SUCH AS A BEARING WALL,EXCEPT C_ _ WHERE ADJOINING ROOF PLANES PROVIDE A 3 FT WIDE 4 CLEAR ACCESS PATHWAY.(NFPA 1 11.12.2.2.2.1.1) U M 3 PHOTOVOLTAIC MODULES SHALL BE LOCATED NO LESS Ui Z J THAN 3 FT BELOW THE RIDGE.(NFPA 111.12.2.2.2.2) LL 0 5 6 m O _j 1.5 FT.WIDE FIRE ACCESS PATHWAY L.L 2O ROOF ACCESS POINT J 0 w 7 O3 ROOF ACCESS POINT Cn > O3.0 FT.WIDE SMOKE-VENTILATION SETBACK,PER NFPA o 1 11.12.2.2.2.2 W W O5 1.5 FT.WIDE FIRE ACCESS PATHWAY j N IV PV MODULES INSTALLED ON ROOF WITH QUICK MOUNT O 9 8 co PV QRAIL MOUNTING SYSTEM.THE MOUNTING SYSTEM \ IS UL 1703 CLASS A FIRE RATED ON A 5112 SLOPED !� 10 ROOF WHEN INSTALLED WITH TYPE 1 OR 2 MODULES. C� THE APTOS SOLAR DNA-1 20 325 IS TYPE 1. I/P 3.0 FT.WIDE SMOKE-VENTILATION SETBACK,PER NFPA 111.12.2.2.2.2 +�"'+rrrr O3.0 FT.WIDE SMOKE-VENTILATION SETBACK,PER NFPA 1 11.12.2.2.2.2 t�y ' SF••02 O3.0 FT.WIDE FIRE ACCESS PATHWAY,PER NFPA 1 ./ No_ 391 •'�� 9 11.12.2.2.2.1.1 * �`\ 10 3.0 FT.WIDE FIRE ACCESS PATHWAY,PER NFPA 1 11.12.2.2.2.1.1 11 ROADWAY ��F• Z R10..•����.` TOTAL PLAN VIEW ARRAY AREA IS 324.4 SQ.FT,WHICH FIRE SAFETY PLAN 12 REPRESENTS 12.4%OF TOTAL PLAN VIEW ROOF AREA (2611.8 STT) FIRE SAFETY PV-7 SCALE: 1"=20' THIS SYSTEM UTILIZES MICROINVERTERS.THERE ARE PLAN 13 NO DC CIRCUITS OUTSIDE OF THE ARRAY PERIMETER OR INSIDE THE BUILDING. 14 CABLES,WHEN RUN BETWEEN ARRAYS,SHALL BE DOC ID:150633-185713-1 ENCLOSED IN CONDUIT. DATE:12/9/20 CREATOR: REVIEWER: REVISIONS IPV-71 `*,,ova • *RFyFs. co '- o �� X % :•v o DNA- 120 DNA ALL - BLACK DESIGN tp' 'tos'" 330W I 325W 1 320W BLACK FRAME, solartechndogy HIGH EFFICIENCY HALF-CUT CELL PANEL . . • DNA-120•MF23.320W DNA-120 MF23-32&W DNA-120MF23•300 u ure•2S'C STCrated output Rapp(W) 320 325 330 ••...,•..•.a 3utw Module Efficiency 18.96% 19.25% 19.54% M,•N••„r Open Circuit Voltage V20 (V) 39.92 40.10 40.27 Short Circuit Current I•e(A) 10.35 10.43 10.51 • � „• Rated Voltage Vmmp(V) 32.51 32.71 32.91 Rated Current lmmp(A) 9.84 9.93 10.02 2 Standard Test Conditions for front-face of panel: 9• 20 : r w to 1000 W/m2,25°C,measurement uncertainty≤3% 1 __________________________ "+•wM . . - Temperature Coefficients Pmpp -0.40%/°C Temperature Coefficients l +0.046%/°C Cell Type Monocrystalline Temperature Coefficients Va. -0.306%/°C Glass Low Iron,Tempered ■ 111,11111, Normal Operating Cell 45°C Frame Anodized Aluminum Alloy • Temperature(NOCT) • • , - Junction Box IP67 9Jtc 20A Dimension 1684 x 1002 x 35mm Maximum Series Fuse 4mm2(EU)12AWG, • Maximum System Voltage 1,500 VDC(UL&IEC) Output Cable 39.37in(1000mm) • -• • •. ••• 41.9lbs. 19k9) ' •• •- • Weight ( UL1703 175mph Wind Rating Fire Performance Class Class C/Type 1 • Cable Length 1200mm A • a • •.• Maximum Load Capacity(Per 5,400PA Snow Load • • •. • • � • 30 Number of Modules per Pallet Number of Pallets per 40ft HQ 26 Container Pallet Dimensions(mm) 1720X 1140 X 1140 wool Pallet weight(kg) 620 Container weight(kg) 16120 • '• • E • • E E E • F m o • , ■I. -i I I . • 2 , • •. . 1 -- -yir ► _. • . • • • • _ j LISTED O- 1DDzmm 3Smm 952mm DNA-120-MF23-XXXW RESIDENTIAL COMMERCIAL Aptos Solar Technology reserves the right to make specification changes without notice I,.,.• +rr', =^� O ���G: Vo 'I• 00 Z m to z:x Data Enphase IQ 7 and IQ 7+ Microinverters Enphase Microinverters INPUT DATA IQ7-60-2-US/IQ7-60-B-US IQ7PLUS 72-2-US/IQ7PLUS-72 IQ7PLUS-72-B-US _ .F,; Commonly used module pairings' 235W-350W+ 235W-440W+ Module compatibility 60-cell PV modules only 60-cell and 72-cell PV modules Maximum input DC voltage 48 V 60 V Peak power tracking voltage 27 V-37 V 27V-45V Operating range 16V-48 V 16 V-60 V Min/Max start voltage 22 V/48 V 22 V/60 V Max DC short circuit current(module Isc) 15 A 15 A Overvoltage class DC port II II Enhose The high-powered smart grid-ready DC port backfeed current 0 A 0 A pEnphase IQ 7 Micro"and Enphase IQ 7+Micro" PV array configuration 1 x 1 ungrounded array;No additional DC side protection required; Q 7 and IQ 7+ dramatically simplify the installation process while AC side protection requires max 20A per branch circuit OUTPUT DATA(AC) IQ 7 Microinverter IQ 7+Microinverter achieving the highest system efficiency. Peak output power 250 VA 295 VA Microinverters Part of the Enphase IQ System,the IQ 7 and Maximum continuous output power 240 VA 290 VA Nominal(L-L)voltage/range2 240 V/ 208 V/ 240 V/ 208V/ IQ 7+Microinverters integrate with the Enphase 211-264 V 183-229 V 211-264V 183-229V IQ Envoy"',Enphase IQ Battery"',and the Enphase Maximum continuous output current 1.0 A(240 V) 1.15A(208V) 1.21 A(240V) 1.39A(208V) Nominal frequency 60 Hz 60 Hz Enlighten'"monitoring and analysis Software. Extended frequency range 47-68 Hz 47-68 Hz IQ Series Microinverters extend the reliability AC short circuit fault current over 3 cycles 5.8 Arms 5.8 Arms Maximum units per 20 A(L-L)branch circuit' 16(240 VAC) 13(208 VAC) 13(240 VAC) 11(208 VAC) standards set forth by previous generations and overvoltage class AC port III Ill AC port backfeed current 0 A 0 A undergo over a million hours of power on testing, Power factor setting 1.0 1.0 enabling Enphase to provide an industry-leading Power factor(adjustable) 0.85 leading...0.85 lagging 0.85 leading...0.85 lagging Warranty of up to 25 years. EFFICIENCY @240 V @208 V —@240 V @208 V Peak efficiency 97.6% 97.6% 97.5 CEC weighted efficiency 97.0% 97.0% 97.0% 97.0% MECHANICAL DATA Ambient temperature range -40°C to+65°C Relative humidity range 4%to 100%(condensing) Easy to Install Connectortype(IQ7-60-2-US&IQ7PLUS-72-2-US) MC4(or Amphenol H4 UTX with additional Q-DCC-5 adapter) Connector type(IQ7-60-B-US&IQ7PLUS-72-B-US) Friends PV2(MC4 intermateable). • Lightweight and simple Adaptors for modules with MC4 or UTX connectors: -PV2 to MC4:order ECA-S20-S22 • Faster installation with improved,lighter two-wire cabling -PV2 to UTX:order ECA-S20-S25 • Built-in rapid shutdown compliant(NEC 2014&2017) Dimensions(WxHxD) 212 mm x 175 mm x 30.2 mm(without bracket) Weight 1.08 kg(2.38 Ibs) Cooling Natural convection-No fans Productive and Reliable Approved for wet locations Yes Optimized for high powered 60-cell and 72-cell*modules Pollution degree PD3 More than a million hours of testing Enclosure Class II double-insulated,corrosion resistant polymeric enclosure • Class II double-insulated enclosure Environmental category/UV exposure rating NEMA Type 6/outdoor FEATURES _ UL listed Communication Power Line Communication(PLC) Monitoring Enlighten Manager and MyEnlighten monitoring options. Smart Grid Ready Both options require installation of an Enphase IQ Envoy. "'- Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load break • Complies with advanced grid support,voltage and disconnect required by NEC 690. frequency ride through requirements Compliance CA Rule 21(UL 1741-SA) UL 62109-9-1,UL1741/IEEE1547,FCC Part 15 Class B, ICES-0003 Class B,• Remotely updates to respond to changing CAN/CSA-C22.2 NO.107.1-01 grid requirements This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and • Configurable for varying grid profiles NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems,for AC and DC conductors,when installed according manufacturer's instructions. — — Meets CA Rule 21 (UL 1741-SA) U L *The IQ 7+Micro is required to support 72-cell modules. . No enforced DC/AC ratio.See the compatibility calculator at htto /s /ennh^se com/en-us/support/module-comoatib ty 2-Nominal voltage range can be extended beyond nominal if required by the utility. 3.Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. ENPHASE. To learn more about Enphase offerings,visit enphase.com ENPHASE. To learn more about Enphase offerings,visit enphase.com have Energy All rights reserved.All trademarks or brands used are the property of Enphase Enerc.Inc 2018-11-19 __ - RaiiTM- Fully Integrated Mounting and Racking System Fast, Simple Installation: It Just Clicks Q g The QRail Series is a strong and versatile solar array mounting system that provides unrivaled benefits to solar QCIickTechnolo�y"" designers and installers.Combined with Quick Mount PV's industry-leading waterproof mounts,QRail offers a The universal mid and end clamps use patented QClick complete racking solution for mounting solar modules on any roof. technology to simply"click" into the rail channel and remain upright, ready to accept the module.The *v pre-assembled clamps fit virtually all module frames and -�—,. Easily design array configurations with the QDesign software require no extra hardware,eliminating pre-loading and ' application.Generate complete engineering reports and calculate ter- reducing installation time. a precise bill of materials for all the mounting,racking and UNIVERSAL END CLAMP UNIVERSAL BONDED MID CLAMP accessories needed fora complete solar array. 1 2 � 3 '"�" 2clampsformodulesfrom 2clampsformodulesfrom 30-45mm or38-50mm thick 30-45mm or 38-50mm thick click! Installing is as easy as 1-2-3 Comprehensive, One-Source Solution QRail,together with Quick Mount PV's waterproof mounting products, provides the benefit of a single-sourced, QSplice"TochnoIogy QRail's innovative internal QSplice installs in seconds, requiring no seamlessly integrated rooftop installation that works with all roof types—composition/asphalt shingles, Simply insert QSplice into the rail and slide the other flat or curved tile, metal shingle,shake,slate and low slope roofs.The QRaiI system also works with any roof QSPLICE tools or screws. rail on to create a fully structural, bonded splice.An external splice is attachment system for maximum flexibility. also available. 1 2 3 Superior Strength and Versatility QRai1 is engineered for optimal structural performance.The system Installs in seconds—no tools or hardware required is certified to UL 2703,fully code compliant and backed by a 25-year HEAW warranty. QRail is available in Light,Standard and Heavy versions to Fully Integrated Electrical Bonding STANDARD match all geographic locations.QRail is compatible with virtually all LIGHT QRoils come in two lengths— The QRail system provides an integrated electrical bonding path,ensuring that all exposed metal parts and modules and works on a wide range of pitched roof surfaces. Modules can be mounted in portrait or landscape orientation in standard or the solar module frames are electrically connected.All electrical bonds are created when the component II re 168 inches(14 ft)and 208 inches(17.3 ft) .�` ' shared-rail configurations. Mill and Black Finish installed and tightened down. .`Oda•• i2•p ate'1, C1�O� ''�,IIIIIt L'`` ITEM DESCRIPTION QTY. * . THIS EDGE TOWARDS ROOF RIDGE NO FLASHING, ROUNDED CORNERS, 9" X 12" X .040", .438" HOLE, 5052, 1 fig ti MILL L-FOOT, 2" X 3.30" FOR .438" O.D. FASTENER, 2-1/16" SLOT, 6061- 1 2 '�,�'FFR•••••*�id�°�`' T6/6005A-T61, MILL 3 WASHER, SEALING, 5/16" ID X 3/4" OD, EPDM BONDED SS 1 4 LAG SCREW, HEX HEAD, 5/16" x 4", 18-8 SS 1 J*5 STRUCTURAL SCREW, QMPV, T-30 HEX WASHER HEAD, 5/16" X 4-1/2", 1 18-8SS 12.00 *5 4 -* STRUCTURAL ( 4.20 ) 3 SCREW 3.00 AVAILABLE ON QMLM-ST VERSIONS ONLY 2 9.00 2.00 1 I 0 .397 .00 2.09 U1 AVAILABLE IN MILL, 3.30 ( •90 AND BLACK FINISHES yick Mount P � 040 - - TITLE: 4.04 QMLM & QMLM-ST: L-MOUNT, ( 2.50 ) ( 3.54 ) 2.75 2-1 /16' SLOT QMLM QMLM-ST UNLESS OTHERWISE SPECIFIED: SIZE DRAWN BY: RAD REV DIMENSIONS ARE IN INCHES TOLERANCES: DATE: 7/16/2018 9 FRACTIONAL± 1/8 TWO PLACE DECIMAL ±.19 PROPRIETARY AND CONFIDENTIAL .094 SCALE: 1:4 WEIGHT:1.0723 SHEET 1 OF 1 THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF QUICK MOUNT PV. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE DO NOT SCALE DRAWING WRITTEN PERMISSION OF QUICK MOUNT PV IS PROHIBITED. COPYRIGHT©2016 QUICK MOUNT PV THREE PLACE DECIMAL ± 5 4 3 2 1