Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
20-1243
f City of Zephyrhills PERMIT NUMBER 5335 Eighth Street Zephyrhills, FL 33542 ELCMISC-001243-2020 Phone: (813)780-0020 r' Fax: (813)780-0021 Issue Date: 01/26/2021 I Permit Type: Electric Service Replacement/Misc Property Number Street Address 1126 210010 03600 0010 5835 11 Th Street Owner information Permit Information Contractor Information Name: HARRY ALONSO Permit Type:Electric Service Replacement/M Contractor:TITAN SOLAR POWER FL Class of Work:Add/Alter Residential INC j Address: 5835 11Th St Building Valuation:$0.00 1 ZEPHYRHILLS,FL 33542 Electrical Valuation:$15,000.00 Phone: (813)363-6652 Mechanical Valuation: Plumbing Valuation: Total Valuation:$15,000.00 Total Fees:$172.50 Amount Paid:$172.50 Date Paid:1/26/2021 10:23:51AM R—Ko I WE ti Description INSTALLATION ROOF MOUNT SOLAR PV Application Fees Electrical Plan Review Fee $57.50 Electrical Permit Fee $115.00 REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each subsequent reinspection. Notice: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permit required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner:Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications add fee Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. CONTRACTOR SIGNATURE ^` _' =' PE IT OFFICE - ---PERMIT EXPIRES IN 6 MONTHS=WITHOUT APPROVED INSPECTION' i� -- -- CALL FOR INSPECTION=8-HOUR_NOTICE REQUIRED --- - -- - PROTECT CARD FROM WEATHER 1 0- 813-780.0020 ofZephyrhil(s PermitApplicatl Fax8i- 3-70 ez 1 Building Department Dale Recei d _ Q Phan Con ctfG Ii n ( � ): sect si _ q - Owr;er' Name �' \ caner o or Ow er's Address` j��S� _ `a0wn_orPhone Number Fe Simple Titleholder Name Owner Phone Number Fee Simple �tdrress�s `�` �{ r�T JOB ADDRESS ::303 V\ �• ,��1`,��J�`y`S- �"..��^7-'�`'"l'[ LION# SUBDIVISION PARCEL IDS I 1 z(s G.. IOOTAiNEO FROM PROPERTY TAX NOTICE) WORK PROPOSED NEVJroNsiR® ADD/ALT [_] SIGN {= DEMOLISH 11 INSTALL REPAIR PROPOSED USE SFR = Comm ® OTHER -7 1, L TYPE OF CONSTRUCTION Q BLOCK FRAME 1 L] STEEL DESCRIPTION OF WORK } BUILDING SIZE SQFOOTAGE= HEIGHT L'-S'a K:C'[-L'C Q-[L4C1E C S U ct'Ar x["CL 6"L A[`[-[ft L C[6 C L'i-C[l;["C C>i C C 4 C C"[X IC'C["r =BUILDING 1.g-r VALUATION OF TOTAL CONSTRUCTION ELECTRICAL S".� � e�I AMP SERVICE PROGRESS ENERGY = W.R.E.C. =PLUMBING $.. I /� n ^ n I; =MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION =GAS = ROOFING Q SPECIALTY = OTHER 5 v FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES NO BUILDER COMPANY SIGNATURE REGISTERED YIN. FtEcLVFFa N- IT Address - -- . . License# ELECTRICIANS COM ANY Y�N FEE CURREN Y SIGNATURE � --r1'14 Address t G..ti l( \ DJJ�L License#` • "_ �`� `. . PLUMBER COMPANY - - SIGNATURE ftEGISTCREO ^!_jam FEECURREN 1 Address License#f MECHANICAL COMPANY SIGNATURE REGISTERED I Y1N FEE curlReNY/N- Address License# OTHER COMPANY SIGNATURE REGISTERED Yl•N FEECURREN Ya.N Address License# is l,t,iflr6lfR'4'B'Q1,lYlove tt Write it at l If all-142 its fe.101tter'E4iC-11V-tG`REIIlDftt44i its glut RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit fornew construction, _Minimum ten(10)working days after submittal dale,Required onsite,Construction Plans,Stormwaler Plans wl Sill Fence installed, _.._ .- . ItalyVamfM flIIftt�tSl£P'SIt2fVGfHf trfftlCfUt90Utlt415tCii^uRf[gtTtRoJL ... .-..___._.._.. .._..._ - ..-._.. _.--_.,-. ._ -. .. .._.. COMMERCIAL AtInch(2),complete refs al:B ill'!, 11,11 'p14 a Lifd Sstety`Pnge;(1)snt Gf.En4fity Forms.R-O-W Pornit tpr 11ew Construction. f:4inimum ten(14)wwkii.1 days aitD7 sobniitfnt.date..Requlmd'onsite;Constriction Plans,$Iomtwaler Plnns.ti/Silt Faroe Installed,. Sitnlite !, 1(it(es:61;duii11a5ter.S11d,Nr<irk'f i@n,if tot 1 flaw pfcJecis:'AR c+�mtnalcfaJ`regUirem_stiss must tract compliance SIGN PERMIT Attach(2)sets of Engineered Plans. ""PROPERTY SURVEY required for all NEW construction. Dlrectians: _ Fill oul application completely. Owner&Contractor sign back of application,notarized If over$2600,a Notice of Commencement Is required.(AIC upgrades over$7500) Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs If shingles. Sewers Service Upgrades AIC Fences(PIoUSurvey/Footage) - - Driveways-Not over Counter If on public roadways..needs ROW - INSTR#ZUZU I 1,ZU'I U OR BK'I U'l yb PG-I 4U( Page 1 of 1 10/14/2020 09:35 AM Rcpt:2215057 Rec:10.00 DS:0.00 IT:0.00 Nikki Alvarez-Sowles,Esq.,Pasco.County Clerk&Comptroller Permit No Parcel ID No 11-26-21-0010.03600-0010 NOTICE OF COMMENCEMENT Qr Stale of FL County of Pasco THE UNDERSIGNED hereby gives notice that Improvement will be made to certain real property,and In accordance with Chapter 713,Florida Statutes, the following information Is provided in this Notice of Commencement: 1. Description of Property:Parcel Identification No.11-26-21-0010-03600-0010 Street Address: 5835 11th St Zephyrhills FL 33542 2. General Description of Improvement solar PV installation CL_ 3 Owner Information or Lessee information if the Lessee contracted for the improvement: 1✓ Harry Alonso.Ramona Amadis Name 5835 11 th St Z,phyrhills FL 33542 Address City State Interest in Property: owner Name of Fee Simple Tltieholder. (If different from Owner listed above) Address city Slate 4. Contractor. Titan Solar Power FL Name 12221 N US T01 Thonotosassa FL 33592 Address city Stale Contractors Telephone No,: 8139829001 5. Surety: _ Name Address -City State Amount of Bond:E Telephone No.: 6. Lender. Name Address City State Lenders Telephone No.: 7. Persons within the Slate or Flodda designated by the owner upon whom notices or other documents may be served as provided by - Section 713 13(t)(a)(7),Flodda Statutes: Name Address city Slate Telephone Number of Designated Person: 8. In addition to himself,the comer designates of to receive a copy of the Uenors Notice as provided in Section 713.13(1)(b),Florida Statutes. Telephone Number of Person or Entity Designated by Owner. 9. Expiration date of Notice of Commencement(the expiration date may not be before the completion of construction and final payment to the contractor,but will be one year from the date of recording unless a different dale is specified): WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER713, PART1, SECTION713.13,FLORIDA STATUTES,AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION.IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. Under penalty of perjury,I declare that I have read the foregoing notice ofmmoncement and that the facts stated therein are We to the best of my knowledge and belief. STATE OF FLORIDA COUNTY OF PASCO / Signature of Owne ssee, tors or Lessee's Authorized DHIcadDireclor; erRNan g 9 Signatory's Tille/Oflice The loregam msimment was acknowledged bbAot��oro me this a3 da or A 20 f1 by�J Nw N err1�� _ _as Al OAS d q(I (type of authority.e.g.,officer,trustee,attorney in fact)for .! (name ojpa�iy on behalfom instrument was executed).Personally Known[:1 PR Produced Identification ly Notary Signature, ✓`�" Type of Identification Produced DL Name(Pdnl)_ V r I L VICTOR BONILLA "�J:-�;,•,Notary Public-State of Florida I• Commission#GG 951943 My Commission Expires January 28,2024 wpdatalbcslnoll.mmmenmmenlyc053048 "'•"' •- 613-780-0020 City of Zephyrhills Permit Application Fax-M-780-0021 Building Department NOTICE OF DEED RESTRICTIONS:The undersigned understands that this permit may be subject to'deed'restdclione which may be more restrictive than County regulations.The undersigned assumes responsibility for compliatico with any applicalKe deed restdClons. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES:If the owner has hired a contractoror contractors to undertake work,they may be required to be licensed in accordance with state and local regulations,If the contractor is not licensed as required by law,both the owner and contractor may be cited for a misdemeanor violation under slate law.,((the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work,they are advised to contact(he Pasco County Building Inspection Division—Licensing Section at 727-847-8009, Furthor4nofe,i(llu owner ties hired a contractor or contractors,he is advised to have the contmctof(s)sign portions of the"contractor Block',a[•lhis application far whilcll tlfey will be responsible.If you,as the owner sign as the contractor,that may be an Indication that he is not property licensed and is not entitled to permilling privileges Id Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES:The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings,change of use in existing buildings,or expansion of existing buildings,as specified In Pasco County Ordinance number 89.07 and 90-D7,as amended;The undersigned also understands,that such fees,as may be due,will be Identified at the time of permitting.It is further understood that Transportation Impact Fees and Resource Recovery 'Foos must be paid pilot to recelvifig a'cetOuoare 6f 6=paficy'orfirtal powerrelease.if the project•fides not Involve a certificslo of occupancy 6r final IW,.ver release,the'ioCs must be'gold pdoi to petmU.Issaance,.Furifictmore,if Pucco County WalorlSe' r impact fees aredu0,they must be paid Fdor ld permit issuance in accoidance;vdlti appl ca le Pasco County ordinances• CONSTRUCTION LIEN LAW(Cbopter-719,Florida Statutes,as-amended):If valuation of work Is$2.500.00 or more,I certify that I,the applicant, have been provided with a copy of the'Flodda Construction Lien Law—Homeowners Protection Guide'prepared by the Florida Department of Agriculture and Consumer Affairs.If the applicant is someone other than the'owner,I certify that I have obtained a copy of the above described document and promise In good faith to deliver It fo the"owner'prior to commencement. CONTRACTOR`SIOWNEWS AFFIDAVIT:I certify Ihat,all the information In this application is accurate and that all work will be done,ln compliance with all applicable laws regulating construction,zoning and land development,Applicalon Is hereby made to obtain a permit to.do work and lnssAalion as indicated.I certify that no work or Installation has commenced prior to issuanco,of a permit.and that all vrorf.wjii b6.p_rforflted'lo meet standards of all taws regulating construction,County and City codes,zoning regulations,and land development regulations in the jurisdiction.I also certify that I understand that the regulations of other govemment agencies may apply to the Intended work,and that it is my responsibility to Identify what actions 1 must take to be in compliance.Such agencies include but are not limited to: Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands,Water/Wastewater Treatment. Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. Army Corps of Engineers-Seawalls,Docks,Navigable Waterways. Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. US Environmental Protection Agency-Asbestos abatement. Federal Aviation Authority-Runways. I understand that the following resldcllons apply to the use of fill: Use of fill is not allowed in Flood Zone"V"unless expressly permitted. If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume"will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction,I certify that fill will be used only to fill the area within the stemwail. If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties,If use of fill is found to adversely affect adjacent properties,the owner may be cited for violating the conditions of the building permit Issued under the attached permit application,for lots less than one(1) acre which are elevated by fill,an engineered drainage plan is,requinid, Ill am the AGENT FOR THE OWNER,I promise In good faith to inform Ihe_tilvnerof the permuting coisdifions set forth in this affidavit prior to commencing construction.I understand(hate separate permit maybe required for electrical work,plumbing,signs,wells,pools,air conditioning,gas,or other Installations not specifically Included In the application.A permit Issued shall be construed to be a license to proceed with the work and not as authority to violate,cancel,alter,or set aside any provisions of the technical codes,norshall Issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans,donstructidn orvio)attuns of any.codds.Every pormlflssydd shall become Invalid uniess the work authorized by such penpif fs,commenced within six months of pertrilt issuance,or it work authmfied*the"permills`suspotided of ebandoned fora period of six(6)months after the time the work is commenced.An extension maybe requested,In writing,from the eulldlgg Ofgclal for a'parlud notdo exceed ninety(90)days and will demonstrate justifiable cause for the extension.if v&k ceases for ninety(90)consecuuve:daysi'he job Is considered abandoned. WARNING TO OWNER:YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY.IF YOU INTEND TO OBTAIN FINANCING,CONSULT xjtlTFt YOtfR LENbF�j`OR AN'ATTORNEY-B .FORE'RECORQING YYOU�O33GE OF COMMENCEMENT ,FLORIDAJVFAT.,(F.S;;117;03)" OWNER OR AGENT ',CO!NTRACTOR Subscdbed an bswam to(or affirmed)before me this SubscriEedund m' (ar r ed).betaN ma.lhis• y ►t t� Who islare personally known to me or hasfhave pioduced lhhii;lslero'ptitsoltally kn Yr41 ta;me or}irrztjravapiudue�id 4ildenfificallon. ii ttfanfi(t dloa} Nolii"ry,Pub�c NolaryPublic ommission_No' Commission ido. �"•�''`-- = - - J;' amnai otruylypad;pf(nta or5iwnped NattleotNotary•'lyped orstampaq �;arup. CORE DEE PORASiK Notary Public-State 0f Florida Commission P GG 310262 ?,pares My Cdhimi�sion Expires !fill' March 'I'l, 2023 PROJECT DESCRIPTION SYSTEM CAPACITY:6.825 KW DC/6.0 KW AC NORTH PV PANELS:(21)Q.PEAK DUO-G5 325W BY QCELLS OPTIMIZERS:(21)P340 BY SOLAREDGE N Q`G`NGS INVERTER:(1)SE6000H RGM-US BY SOLAREDGE `O(G RACKING SYSTEM:CROSS RAIL 48 XL EVEREST PROJECT INFORMATION QUO P'J STRING INVERTER 61 PROJECT LATITUDE 28.242511 MIN AMBIENTTEMP 1 °C 4 PV DISCONNECT PROJECT LONGITUDE -82.180846 MAX AMBIENT TEMP 35°C 1MND EXPOSURE B EXIS'T:hi ELECTRICAL 1 TER AHJ ZEPHYRHILLS MAX WIND SPEED 138 MPH /I DRAWINGS INDEX 2 LOCATION MAP / WIND ZONES C-1 COVER SHEET N.T.S. C-2 SAFETY PLANS i E-1 ONE LINE RISER DIAGRAM E-2 SAFETY LABELS S-1 STRUCTURAL PLAN S-2 RACKING PLAN D-1 PV MODULES DATA SHEET D-2 SMART MONITORING DATA SHEET t�OO D-3 INVERTER DATA SHEET _ F GENERAL NOTES PER FL.STATUTE 377.705(REVISED 7/1/2017),I RAFAEL A.GONZALEZ SOTO, P.E.83104 AN ENGINEER LICENSED PURSUANT TO CHAPTER 471, CERTIFY THAT THE PV ELECTRICAL SYSTEM AND ELECTRICAL .. :: COMPONENTS ARE DESIGNED AND APPROVED USING THE STANDARDS CONTAINED IN THE MOST RECENT VERSION OF THE i FLORIDA BUILDING CODE. APPLICABLE CODES:2017 FLORIDA BUILDING CODE 6TH,ASCE 7-10 MINIMUM DESIGN LOADS FOR BUILDING AND OTHER STRUCTURES, ,, NEC 2014 ELECTRICAL CODE�: =1� yy ��poF ALL WIND DESIGN CRITERIA AND PARAMETERS ARE FOR HIP AND ALL WORK SHALL COMPLY W �OOFS,CONSIDERING FROM A 7°TO A MAXIMUM IRRADIANCE MAP y CODES FLORIDABUILDING IIOI G C EN AL O MAXIMUM 61T PITCH ROOF IN SCHEF H EI ALL IOENTIAL ROOFS SHALL NOT EXCEED 30'-0"MEAN ROOF HEIGHT. 3 NATIONAL ELECTRIC ROOF SEALANTS SHALL CONFORM TO ASTM C920 AND ASTM 6511, N.T.S. D 2 op AND THE CITY OF ZEPHYRHI ESPONSIBILITY OF THE CONTRACTOR TOPILOT FILL ALL HOLES. CONTRACTOR SHALL ENSURE ALL ROOF PENETRATIONS TO BE pL� i �S�&. ORDINANCES INSTALLED AND SEALED PER 2017 FLORIDA BUILDING CODE OR <,o' . LOCAL GOVERNING CODE. 3 I ' per '9� L WIRING METHODS AND INSTALLATION PRACTICES SHALL YC'/ �F.O ' DEC 3 1 NFORM TO THE NATIONAL ELECTRICAL CODE(NEC)2014, LOCAL 7 _ yn� C>, C� REVIEW DATE TATE CODES, AND OTHER APPLICABLE LOCAL CODES. MEANS Z ,•'�- _ '� r- i' °i(��j G� CITY OF ZEPHYRHILL SHALL BE PROVIDED TO DISCONNECT ALL CURRENT CARRYING ;. �jy r Cy A CONDUCTORS OF THE PHOTOVOLTAIC POWER SOURCE FROM ALL PLAN EXAMINER OTHER CONDUCTORS IN THE BUILDING. CONNECTORS TO BE RQUED PER DEVICE LISTING, OR MANUFACTURERS _� RECOMMENDATIONS.NON-CURRENT CARRYING METAL PARTS SHALL `��� I I I /// BE CHECKED FOR PROPER GROUNDING. ` ���L� REQUIRED SAFETY SIGNS AND LABELS SHALL BE PERMANENTLY �` v�' �` �� ATTACHED BY ADHESIVE,OR OTHER MECHANICAL MEANS,LABELS �/ �P �dCE�s� 55 '� WITH SHALL COMPLY ARTICLE 690 VI OF THE NEC 2014 OR OTHER � ��� NO S 0 APPLICABLE STATE AND LOCAL CODES.SEE LABELS AND MARKING �C_ * 83104 p PAGE FOR MORE INFORMATION. - - RACKING ROOF MOUNT SYSTEM SHALL BE INSTALLED FOLLOWING 1_- .. ''(_ �► ,�,1f 7� �c 1 MANUFACTURERS INSTRUCTION SPECS,INCLUDING ALL GROUNDING J WEEK CLIPS,GROUND LUGS,AND RAIL SPLICE KITS FOR ELECTRICAL o STQ� {6 �y` CONTINUITY. [ e� El �� 3D RENDERING OOF PLAN VIEW ! BOS LOCATION ORlF5A•. • �� M ILDINGDTDESIGN WIND P ESSUR ARE A LCULATNCLOSED ��P �® �\ ASCE17-GO EQUATION 30160.ALL NOTESSINAFGURESC SCE 7010 30!4G N.T.S. N.T.S. AL AND HEIGHT 30.4-2(A,B ST BANDE $67C) HN VE60 FBEEN INCORPORATED. MEAN ROOF ISSUED FOR PERMIT 09-01-2020 ENGINEER CONTACT INFORMATION ENGINEERING STAMP CONTRACTOR CONTACT INFORMATION CONTRACTOR LOGO CUSTOMER: SHEET NAME: RAMONA AMADIS REV DESCRIPTION DATE ENGIPARTNERS, LLC TITAN SOLAR POWER FL Digitally si 255 GIRALDA AVE gned PROJECT ADDRESS: COVER SHEET C.A.32661 ; rby 12221 N US HIGHWAY 301,; Rafael A * TITAN E 5835 11TH ST CORAL GABLES,FL 33134 ;-r'I*/,n `i_Gonzalez Soto THONOTASASSA,FL 33592 ZEPHYRHILLS,FL 33542 PROJECT ID: ENGINEER OF RECORD: SHEET TITLE: ,an /Date: S 0 L A R P O W E R ENG.RAFAEL A.GONZALEZ SOTO,PE C-1 DESIGN@ENGIPARTNERS.COM 2020.09.03 (813)982-9001 - TSP50689 � 07:59:47-04'00' PARCEL NUMBER: DATE: SHEETS: •,,,,,,, 11-26-21-0010-03600-0010 09-01-2020 1 OF 9 786-393-4740 '• #EC13008093 - NORTh "PROPERTY SIDE FACING STREET" PV STRING INVERTER#1 PVDESCONiSEGT I EXISTING ELECTRICAL METER FLAT ROOF is I � L FLAT ROOF M1 , LOCATION OF NEAREST URGENT CARE FACILITY p GQN ... ,// ............ /, NAME: V F s0 ADDRESS: cr`z NO. 83104 PHONE NUMBER: * �C ��l, ar NOTES: STATE, I l o/<.' &1 1. INSTALLERS SHALL DRAW IN DESIGNATED SAFETY AREA AROUND HOME ED pCQR1�P, ; 2. INSTALLERS SHALL UPDATE NAME ADDRESS AND PHONE NUMBER OF NEAREST SAFETY PLAN ��j�S�, .•••'•' ��� URGENT CAR FACILITY RELATIVE TO THE SITE BEFORE STARTING WORK N.T.S. ISSUED FOR PERMIT 09-01-2020 ENGINEER CONTACT INFORMATION ENGINEERING STAMP CONTRACTOR CONTACT INFORMATION CONTRACTOR LOGO CUSTOMER: SHEET NAME: REV DESCRIPTION DATE ENGIPARTNERS, LLC Igl y RAMONAAMADIS TITAN SOLAR POWER FL signed by PROJECT ADDRESS: SAFETY PLAN TITAN C.A.32661 ;`eE a.t«..,E,s Rafael A 12221 N US HIGHWAY 301 255 GIRALDA AVE `" y. Gonzalez Soto 5835 11TH ST CORAL GABLES,FL 33134 '" °0^ ' THONOTASASSA,FL 33592 ZEPHYRHILLS,FL 33542 PROJECT ID: ENGINEER OF RECORD: SHEET TITLE: e5r 'Date: S 0 L A P P 0 W E P ENG.RAFAEL A.GONZALEZ SOTO,PE C-2 2020.09.03 DESIGN@ENGIPARTNERSCOM '+;Fss;oHq'E : (813)982-9001 TSP50689 (� 07.59.55 PARCEL NUMBER: DATE: SHEETS 786-393-4740 -0400 #EC13008093 9 : 11-26-21-0010-03600-0010 09-01-2020 2 ' 2 OF WIRE SIZES,QUANTITY&TYPE RACEWAY SIZE,TYPE,LOCATION&INFO. WIRE AMPACITY CALCULATIONS ADDITIONAL INFORMATION 1 I125%OF WIRE DE-RATED CALCULATION WIRE TAG CONDUCTOR NEUTRAL GROUND RACEWAY RACEWAY RACEWAY HEIGHT OUTPUT MIN VOLTAGE CONDUIT QTY.SIZE&TYPE QTY.SIZE&TYPE QTY.SIZE&TYPE SIZE&TYPE LOCATION ABOVE ROOF CURRENT OUTPUT OCPD WIRE AMBIENT #OF FINAL DIST. VOLTAGE DROP% FILL% CURRRENT RATING TEMP COND. AMPACITY DC(BEFORE JB) (2)#10 AWG PV WIRE N/A (1)#8 AWG BARE COPPER NOT APPLICABLE UNDER ARRAY 1/2"TO 3-1/2" 15A 18.8A 20A 40A X 0.76 X 1 =30.4 A 10 FT. 350V 0.11% 6.4% DC(AFTER JB) (4)#10 AWG THWN-2 N/A (1)#8 AWG THWN-2 3/4"EMT CONDUIT ABOVE ROOF 1/2"TO 3-1/2" 15A 18.8A 20A 40A X 0.76 X 0.8=24.3 A 20 FT. 350V 0.21% 8.1% AC(INVERTER TO METER) (2)#8 AWG THWN-2 (1)#8AWG THWN-2 (1)#8 AWG THWN-2 3/4"EMT CONDUIT EXTERIOR WALL "N/A" 25A 31.25A 35A 55A X 0.76 X 1 =41.8 A 5 FT. 240V 0.1% 7.7% STRING#1 A1.1 A1.2 A1.3 A1.4 A1.5 A1.6 A1.7 A1.8 A1.9 A1.10 A1.11 2 3 4 5 PV RAILS TO BE BONDED WITH#8 BARE WIRE] S / STRING#2 6 8 10 ? NEW 200A LINE SIDE __ __ I�j UNFUSED A 9 35A SOLAR READY SIEMENS A2.1 1iT B2.3 62.4 B2.5 B2.6 B2.7 B2.8 B2.9 B2.10 `� T / 7 Q MC4040S1200SC 1 240V/120V 200A BUS BAR NEMA3R 2OOA OR EQUIVALENT OVERHEAD SERVICE INVERTER TOTAL OUTPUT: 25A SAFETY RATING (125%): 31.25A TOTAL PV SYSTEM OCPD: 35A MAIN BREAKER RATING: 200A MAIN PANEL RATING: 200A 120% BACKFEED RATING: 40A ONE LINE RISER DIAGRAM N.T.S. LEGEND: ``\ . 12#10 PV WIRE a` �ti^• , ol ,�i� (21)Q.PEAK DUO G5 325W BY QCELLS 2 1 #8 BARE WIRE GROUND 3 NEMA3R JUNCTION BOX -REFER TO D-1 SHEET s3` i 3/4" EMT CONDUIT 4#10 THWN-2 2#8 L1,L2 THWN-2 1 #8 TWHN 2 GROUND �o' 83 D L� 1 #8 THWN-2 GROUND 5 SE6000H RGM-US BY SOLAREDGE-REFER TO D 3 SHEET 6 1 #8 THWN-2 NEUTRAL 3/4"EMT CONDUIT QQ O = 3/4"EMT CONDUIT 2#8 L1, PV INTERCONNECTION POINT S • �4T 7 PV SYSTEM DISCONNECT RATED 60A 8 1 #8 THWN-2 NEUTRAL 3/4" EMT CONDUIT 9 i�� '•�� ���' �'� 10 NEW UTILITY ELECTRICAL SERVICE ",14'4L ISSUED FOR PERMIT 09-01-2020 ENGINEER CONTACT INFORMATION ENGINEERING STAMP CONTRACTOR CONTACT INFORMATION CONTRACTOR LOGO CUSTOMER: SHEET NAME: REV DESCRIPTION DATE ENGIPARTNERS, LLC Digitally TITAN SOLAR POWER FL RAMONAAMADIs ONE LINE RISER DIAGRAM 'igned by PROJECT ADDRESS: C.A.32661 ,�'a.co++4�F'-., 12221 N US HIGHWAY 301 T I •T A N 255 GIRALDA AVE `�� :_s, Rafael A 583511TH ST , =Gonzalez Soto THONOTASASSA,FL 33592 ZEPHYRHILLS,FL 33542 PROJECT ID: ENGINEER OF RECORD: SHEET TITLE : CORAL GABLES,FL 33134 = n- ,q�.,,,ry+=_ SOLAR POWER ENG.RAFAELA.GONZALEZSOTO,PE I E-1 - DESIGN@ENGIPARTNERS.COM 2020.09.03 (813)982-9001 TSP50689 PARCEL NUMBER: DATE: SHEETS: " 08:00:03 11-26-21-0010-03600-0010 09-01.2020 3 OF 9 766-393-4740 -04'00 #EC13008093 INVERTER#1 TQVQLTA SY STEM YSTEM w T LABEL LOCATION: WARN N�± DO AIC T ®WARNING DUAL POWEI .SOURCE POINT OF _ PHOTOVOLTAIC SYSTEM`Iw CIRCUIT IS,BACKIF INTERCONNECTION ELECTRICAL SHOCK HAZARD I RATED MPP CURRENT 15 AMPS LABEL LOCATION: PER CODE:NEC 690.64 -' - LABEL LOCATION: INVERTER NEC 705.12(D)(4) DO NOT TOUCH TERMINALS AC DISCONNECT, RATED MPP VOLTAGE 500 VOLTS TERMINALS ON BOTH LINE AND % UA� fR -•--- PER CODE: NEC 690.52 LABEL LOCATION: POINT OF INTERCONNECTION - WARNING N LOAD SIDES MAY BE ENERGIZED PER CODE: NEC 690.17(E) haFAx SYSTEM VOLTAGE ! 480 VDC POINT OF IN THE OPEN POSITION V MAX CiRCUrT CURRENT 25 AMPS r INVERTER OUTPUT ONNECTIO . ?NOT L RELOCATE THIS OVERCURRENT DEVICE INTERCONNECTION PER CODE:NEC 690.64 NEC 705.12(D)(4) PHOTOVOLTAIC AC DISCON1NECTfl LABEL LOCATION I A CAI LABEL LOCATION: 11[I A D A I MAXIMUM AC OPERATING CURRENT. 25 A AC DISCONNECT t i14 MAIN SERVICE PANEL 1[ R t N PER CODE: NEC 690.54 PHOTOVOLTAIC SYSTEM CIRCUIT IS BACKFED PER CODE: NEC 705.10 NOMINAL OPERATING AC VOLTAGE: I 240V NEC 690.45(B)(5) ELECTRICAL SHOCK HAZARD LABEL LOCATION: IF A GROUND FAULT IS INDICATED INVERTER NORMALLY GROUNDED CONDUCTORS PER CODE: NEC 690.05(C) DO NOT DISCONNECT • LABEL LOCATION: MAYBE UNGROUNDED AND ENERGIZED PHOTOVOLTAIC POINT OF UNDER LOAD INTERCONNECTION PER CODE: LABEL LOCATION: NEC 690.33(E)(2) AC DISCONNECT LABEL LOCATION: , POINT OF INTERCONNECTION P -._ -- L--_A JDC DISCONNECT WARNING PER CODE: NEC 690.58(C) ^ _ PER CODE: NEC 690.14(C)(2), LABEL LOCATION: • • DC D I SCON ECT NEC 690.53 TURN OFF PHOTVOLTAIC AC DISCONNECT, MAIN PANEL PER CODE: NEC 110.27(C) AC DISCONNECT PRIOR TO OSHA 1910.145(1)(7) WORKING INSIDE PANEL CAUTION: SOLAR ELECTRIC _ SYSTEM CONNECTED MAINPHOTOVOLTAIC LABEL LOCATION: LABEL LOCATION: POINT OF INTERCONNECTION JjI [ AC DISCONNECT PER CODE:NEC 690.15, NEC 690.13(B) ARNIN PER CODE: NEC 690.54 LABEL LOCATION: SYSTEM DISCONNECT �����iIfill, ELECTRICAL SHOCK HAZARD /i - DC DISCONNECT, INVERTER --- - � THE DC CONDUCTORS OF THIS PER CODE: NEC 690.35(F) Q L�CEN•�'C� ••• PHOTOVOLTAIC SYSTEM ARE UNGROUNDED z •. NA. AND MAY BE ENERGIZED �___ o 3704 WARNING: PHOTOVOLTAIC 1 MAIN S RVIICESS DISCONNECT, DC CONDUIT A SJ ;� Srar POWER SOURCE j PER CODE: NEC 690.31 (E)(3)( j PV SAFETY LABELS DATA ,M4L N.T.S. ISSUED FOR PERMIT 09-01-2020 ENGINEER CONTACT INFORMATION ENGINEERING STAMP CONTRACTOR CONTACT INFORMATION CONTRACTOR LOGO CUSTOMER: SHEET NAME: REV DESCRIPTION DATE ENGIPARTNERS, LLC TITAN SOLAR POWER FL RAMONA AMADIS PROJECT ADDRESS: SAFETY LABELS itll C Dig a y signed .A.32661 -,.`'a.�'SE�:zo, 12221 N US HIGHWAY 301 255 GIRALDA AVE by Rafael A @TITAN 5635 11TH ST CORAL GABLES,FL 33134 a"a,, ,Gonzalez Soto THONOTASASSA,FL 33592 ZEPHYRHILLS,FL 33542 PROJECT ID: ENGINEER OF RECORD: SHEET TITLE: Date: S 0 L A R P 0 W E R ENGIPARTNERS.COM %o :`4oa�o5 E ENO.RAFAEL A.GONZALEZ SOTO,PE E-2 DESIGN @ ,-,'SsroNp` �'3 2020.09.03 (813)982-9001 PARCEL NUMBER: TS P50689 DATE: SHEETS: 4 OF 9 08:00:14-0400' 11-26-21-0010-03600-0010 00-01-2020 786-393-4740 #EC13008093 ULTIMATE WIND SPEED 140 mph NOMINAL WIND SPEED 138 mph NORTy R&K CATEGORY 1I EXPOSURE CATEGORY B ROOF SLOPE ° 27 ROOF TYPE GABLED / "PROPERTY SIDE FACING STREET" PRESSURE ZONE: 1&2 V MEAN ROOF HEIGHT: 13.425 PERIMETER WIDTH: 4 0.85 4 KzT 1.0 ...._� KZ 0.85 VELOCITY PRESSURE(q)=0.00256*K K V 4 VELOCITY PRESSURE (ASD) 14.29 EXTERNAL PRESSURE COEFFICIENT Z1 0.5 -0.9 EXTERNAL PRESSURE COEFFICIENT Z2 0.5 -1.7 EXISTING ELECTRIC METER-1EXTERNAL PRESSURE COEFFICIENT Z3 0.5 -2.6 FLAT ROOF PV DISCONNECT ARRAY B INTERNAL PRESSURE COEFFICIENT 0.18 PV STRING INVERTER SOLAR MODULE TILT=27° ZONES (PRESSURES MAX. MAX. TYP.SEE 2-1 AZIMUTH=336°(NW) (PSF) SPAN(FT CANTILEVER(IN) 1 -18.81 6 24 2 -32.75 4' 16" OBS slti 13 ( -48.43 4' 16" , e -_- TOTAL ROOF AREA 2170026Q.-ft ' - I , TOTAL PHOTOVOLTAIC AREA: 380.89 s . ft , E WIND LOAD(PSF): -48.43 I . t TOTAL WIND LOAD(LBS): -18,446.4 � Ii I I TOTAL ROOF MOUNTS: 71 f TENSION FORCE PER MOUNT(LBS): 259.8 LEGEND & SYMBOLS OBS ROOF OBSTRUCTIONS T ARRAY# FLAT ROOF �___t A1.11 XX.X MODULE# m STRING# ' M A, 1 PV MODULES i i f TRUSSES OR RAFTERS -WOOD TRUSSES/RAFTERS LOCATION-INSTALLER U U ROOF MOUNTS & RAIL MUST VERIFY IN FIELD ROOF SLOPE 1L1THE RAIL EXTENDS A MINIMUM OF 3" BAR RAY A OCOA ED AT CENTER FROM THE EDGE OF THE MODULE-TYP. TILT=27° OF ROOF TRUSS-TYP. AZIMUTH=156°(SE) UL 1703 CERTIFIED MAX.PV MODULE SURFACE LOAD:113.00 psf APPLIED WIND LOAD:-48.43 psf i NOTES: �� GOiy ®'9,J► Q.PEAK -INSTALL MID CLAMPS BETWEEN � h ........ .. ° DUO-G5 gg.34" MODULES AND ENDS CLAMPS AT THE 325W END OF EACH ROW OF MODULES. .�. � '. 0 y -ALUMINUM RAILS SHOULD ALWAYS BE No. 83'04 •' "' FOOTING SUPPORTED ON BY MORE SIDES ON F ONE OF THE • I 1SPLICE. STRUCTURAL ROOF PLAN & PV MODULES LAYOUT �� <or�>IDp 4 SOLAR MODULE ISSUED FOR PERMIT 09-01-2020 ENGINEER CONTACT INFORMATION ENGINEERING STAMP CONTRACTOR CONTACT INFORMATION CONTRACTOR LOGO CUSTOMER: SHEET NAME: RAMONAAMADIS STRUCTURAL PLAN REV DESCRIPTION DATE ENGIPARTNERS, LLC ,,,,, TITAN SOLAR POWER FL Digitally signe PROJECT ADDRESS: CA.32661 s�pr P3�EvsF Fra. by Rafael A 12221 N US HIGHWAY 301 T I T A N 255 GIRALDA AVE ? _:. ^P Gonzalez Soto 5835 11TH ST CORAL GABLES,FL 33134 5*-4i. yF,�,1;1 ° THONOTASASSA,FL 33592 ZEPHYRHILLS,FL 33542 PROJECT ID: ENGINEER OF RECORD: SHEET TITLE: s1Ax+�i d _Date: S O L A R P 0 W E B ENG.RAFAEL A.GONZALEZ SOTO,PE S-1 - DESIGN@ENGIPARTNERS.COM '.90 'ox.\4P'`a J 2020.09.03 (813)982-9001 TSP50689 - - �''•;SSO;m`EH�" PARCEL NUMBER: DATE: SHEETS: •n,,,,,,,,,,,, 08:00:32-0400 11-26-21-0010-03600-0010 09-01-2020 5 OF 9 786-393-4740 #EC13008093 P� �� _.._._.. R FLOEXS�EAL /FLEXSEAL LV 037 CrossRall End Clam CrossRail Mid Clam CrossRaii 48-XL CL-Foot - � --- ' � - Asp R � I a All Season ah Patch -' 1 , •$LptNool Leaks •Adrems lnl4e[UrprYrr.dilian f i � � ,-,, i�� " ^ •IhrMLnvel GraAe t Z}� •Greco Frc Nasty HepaM Mechanical Properties �: I p piiz Pw IdrrrN corm a u'bn+x.x.a srrYA+ l 'rats a? ,t 4 t ,. .,. .,u.'rv+nr ,ter< �.r..:.�r. "�.n 3y.NR..w:i•_.e ss.rmr.mr iii --r— 5 $ ♦� .,..,,�...rnSection Properties j i' "`'`°"'"M„,"a".s""`�"'�' •" " "° .y ^'^" s'"_...._ ...ia ¢.:,�,� _ .. � :r.,w._hrabaa _—,_ ,..;r-.. . ,._... I {� — r,.. ..,. „Yala #i,l t,.. hl :...rl,. - '3 .. M waab I i 1'• OPCOAT"FLEXSEAL' FLE%SFAL'IVTEdINICAL DATA H-are :3.n sear,. a - '.. 1 u ., a ," e, , T _ —_. r ',a� x xYa E0reErna Ras Lmala va�kl+�w. ' ..aoon,c rsun � ir aror od �,z- 50fl 'sz>,. m Technical data T.w.9..e W.oe rv.r rev �.,�,.,...r..,'a Technical data Techni -e Pe vcal data "° T .Nx ry are ary t'Fl a55pa:,m f..z, r. a' -sz�. 1 =:orvarraeliaw' L;..-"a ::�'3;...uJ A� ,+NMK aexrt 50 2be urr c`"*,rr"mr3 ' 055 lirmn 1,10, Weeu- xF'ra<r r,.recr-no,a e Ivey Cimerv0,, "4"o5os atne+'$VYw'r tktLkre river rbtpRy tl 5rvz,Yz**m+A aa. YixzPa'rsz,a —._ 5✓enPrir 37 kx TGD, _ •.._— -- E 2ES Here a Goon,.u-t ixn4c e-nm trio iosws:a .v+vFren .1.s.+w.nw.sa .. F� 'A. .,:..c rr. r,, �y.� tryrL�.i,.asa:.w,...mtb.-u,.,.r,..,r srnc._e..�: e. o,., •c,z•m ,r^: --,a..rn z x:a�a5f=:,:[�7 td c:..i..z.:, e;:n 1 /a _5+. , 0,,00000 - 1E�sr Gsr.:,, w .,rn let 336]556,9 __. , n .. —...,v•,•xx,v,;<a -.,r..s. —"crt.:� or,• „oxM.a�,..wran�,sc,{. .. �. -,-k n�u ,.a _ uLl6son.0.B SHa9TamPa FledN L�_i e13,3g 3,01 NVSI'n["C-1Dx CROSSRAIL END CLAMP FLUSH MOUNT SYSTEM SPAN TABLE(inches) PORTRAIT INSTALLATION(MAXIMUM MODULE Fl� Y-e LAG BOLT LENGTH 66.38"x40")EXPOSURE C na,a.ir5on, �NG�N FLASHING ROOF WIND GROUND SNOW:0 psf ATTACHMENT DIAGRAM 2 ROWS OF RAILS PER MODULE J�°' SLOPE1 SPEED c25)M (degs.) (mph) ZONE 1 ZONE 2 ZONE 3 EXIST.2X WD. 't': TRUSSES OR I 110 94 80 65 C) y RAFTERS L 115 92 76 62 120 91 72 59 1/4"SS 18-8 BOLT 130 86 67 55 FLANGE NUT °P n"r,7. d 1/4"SS SERRATED 2� 7°-27° 140 81 62 51 am rob t PLACE BOLT 00500nfio weer Pe.x o,n.eu,°' 150 77 58 48 orr.ar u1 b0 PV.k •a+. sn s'" r� . <6„srrs post;_use lml AT C.L.OF 160 72 54 44 steers EQ. TRUSS OR 170 67 51 42 wttdnM EQ, 180 64 48 39 c.w n� x,Mwnnmr SEALANT 0.,3'3 Yr wN1Nd,a EVEREST CROSS RAIL(48-XL VERSION - SECTION "A-A" LAG BOLT PULL OUT CALCULATIONS N.T.S. Spruce,Pine, Per inch Thread Depth 2661bs L-FOOT - SS Lag Bolt 5/16"x 4" Min.Thread Depth 0'-3" REFER TO DATA SHEET FOR SPEC' Quick Mount PV' e000noeao05ovon Wood Strength x Thread Depth=Pull Out Strength TITLE: 266 lbs.x 3 in=798 lbs. QMLM:L-MOUNT,5/16"LAG,9" Allowable Pull Out Strength per Lag Bolt 798 lbs. 2X4 TRUSSES 24"O. X 12"FLASHING Max.Pull Out Strength Required per Lag Bolt 259.8 .>- ...,._ .t.r .. ,+,.. .... SIZE oceano I,, van Rev Lag Bolt Pull Out Strength Safety Factor 307 Lag Screw Installation Guidelines QUICK MOUNT A DA E: s,e 6 Uni-Rac Specs.Lag pull-out(withdrawal)capacities pbs) 1.Determine to nst for the Mount on roof by SEE DATA SHEET I DET.ABOVE .P ASPHALT "NYC ='2 drilling through the center of truss from bottom with in typical roof lumber ASD SHINGLES 5/32"drill bit. ��--- 2. Mark mounting holes for Mount on STAINLESS STEEL Lag screw specifications QMLM2: undedayment.Mounting holes should be centered NOTE: i 5/16"SS LAG BOLT 2 X.75"SLOT on the trusses, Specific 5/6"shaft,a VERSION 3.Drill 15/64"pilot hale. SEAL BASE MOUNT TO EXISTING 5116"SS FENDER WASHER H OPTIONAL s 6 4.Apply sealant to bottom of Mount, gravity perinch thread depth ROOF UNDERLAYMENT WITH ROOF I II i5.n Place Mount over roof untlerlayment w h holes in roof. Douglas Fir,Larch 0.50 266 •SEALANT AND MEMBRANE 7 Notes:(1)Thread must be embedded in the side grain of a Trusses or other structural 6.Apply sealant to bottom of Mount,apply sealant 1 (2 J-- member integral with the building structure. to lag screws and fasten Mount securely to Douglas Fir,South 0.46 235 (2) Lag Bolts must be located in the middle third of the structural member, wanes. (3) These values are not valid for wet services. 7.Apply additional sealant to top assembly to be Engelman Spruce,Lodgepole Pine 0.46 235 ROOF UNDERLAYMENT WITH ROOF sure all enetrations are sealed. (MSR 1650 f&higher) (4) This table does qo rtc�}J�a eeppr capacities.it necessary,contact a local engineer to P SEALANT AND MEMBRANE specify lag bbll�s 4sEthregdrdtl n forces. ASCF7-rEvewmyreess"e \ f Hem,Fir,Redwood(close grain) 0.43 212 (5) Install I bolls Ith 1t��aa ¢¢,,W herfl s!< surface(no gap).Do nor over-torque. ,s,c=°wzssna rc°rcan (6) witk4)'a�wal dews vdld tboiogghc c s1 ions shall be multiplied by applicable L pct Hem,Fir(North) 0.46 235 j adbstm �etofs d decessaA/r 5eb��Of.�S�Y ire the American Wood Council NDS z 0 0) Q \_•� Wrw mtm,I( ENS V- •:- nw �ce :area er,mee.aan�,rwn 0.55 307 0 ¢` �_ mho rreue. Southern Pine SHINGLE ROOF MOUNT DETAIL & DATA - �° - 6a,�7 � ' -� m17-'��� "am�em�� d �� ep dm c mzmva Sp ace,Pine,Fir 0.42 205 No. 83104 O — Pa.bra,a"a, �,aaa.ea,�w,aR.m�.eP 5 7�a�a3r�„5P,� T Spruce,Pine,Fir N. .S. R —p- , �mm m.d:n" a m,m" oS R0 oi,e (E of 2 million psi and higher AVAILABLE INr.rCcfyFGo3MILL,AANDTS IBLACK FINISHES Xy grades of MSR and MEL) 0.50 266 +[� •� �e«.m��ere.�e me'r. o'b a::„med Sources:American Wood Council,NDS 2005,Table 11.2A,11.3A. orreries:. ISSUED FOR PERMIT 09-01-2020 ENGINEER CONTACT INFORMATION ENGINEERING STAMP CONTRACTOR CONTACT INFORMATION CONTRAGTORZL'hoO STATE OF • J MER: SHEET NAME: or. RAMONA AMADIS REV DESCRIPTION DATE ENGIPARTNERS, LLC e� —, ••P TITAN SOLAR POWER FL r �O ► a, RACKING PLAN Digitallysigned OJECT ADDRESS: 'N., ;0> 12221 NUS HIGHWAY 301 C.A.32661 a e by Rafael A `° rç 5835 11TH ST 255 GIR GABLES, AVE \� } 7 i3r0+` Gonzalez Soto / r 1 , ZEPHYRHILLS,FL 33542 PROJECT ID: ENGINEER OF RECORD: SHEET TITLE: CORAL GABLES,FL 33134 `ie: THONOTASASSA,FL 33592 ii ��tt T. Date: S 0 L A NJ fF,tl(W R ENG.RAFAELA.GONZALEZSOTO,PE S-2 2020.09.03 DESIGN@ENGIPARTNERS,COM `'•,`'ssouaa'';;,•' (813)982-9001 PARCEL NUMBER: TSP50689 DATE: SHEETS: 11-26-21-0010-03600-0010 09.01-2020 6 OF 9 786-393-4740 #EC13D06093 6 d O L ozoz-10-60 0100-009CO-O LO0-LZ-9z-L L £6090061,03# 0,tio-85:oo:80 05L5-C6E-92Z S133HS :Alva 838W0N 13O9Vd EO'60'OZOZ >'ea"'.n�S , 6990SdSl Laos-Z86(EL9) :,a:o,yo,y o6, WOO'S213N121Vd1`E)N3@7N`01S3O 1Y—a 3d'01OS23lb2NO0'Vl3V9Va'ON3 a 3 M 0 d 8 v'1 0 S o ea o o 311LL133HS :08O039 dO a33NION9 :OI1J3foad Z19££ld'SIIIH9AHd3Z Z6S09 id'VSSVSVlONOHl OdOS Z9EZU09_y: T ` ,yJ: i._ 4E 999 id'S3l8VO 1VSOO IS 519 9.9999 9Av V[IIVaIO SSZ H I 321 e 0 '35N3??1- ^,; L99ZE V O 9.09 J.VMHJIH Sf]N LZZZL Aq pau6ls `'''•�diuca"„••°• 13 H S V. V a A 1^a O� Ad SS3900tl lO3fOad ' ,,,�,,,...• a`J 111 id�I�MOd 2!`d1OS Ntflll /clle;1614 011 S2i�Nl�lb'dIJN3 31tlO NOI1d190S30 0391 slaVwtl vNowva :9WVN.933HS :931901990 00019010591NOO NOLLVWBOdNI 1051900 SO1Otld1NOO dWV1S ONI833NION3 N0ILVW80dNI 10tl1N00 933NION3 0000-90-60 1119934 9106 O9nSSI \�®���+ ALIewaa0 ui paaaOUPU3 AueLuies ui paiaaulaq S113� 511 3) Ulp lnq 9 — ux+asjlaab moo wcrsllaa-6gsals l;`!:31000£Z-669$464£(0)617+T.`:)1444£Z`6ti 99 tr6tr£(O)Eb+ 0uew:a0'ualIoM-01911510999190 TZ-L[aaneuauuoS icul5nP1 Ul ia.u�lawa `.+.0101!04 IP13aG001 _ Hnw0 Sll30H eymuen uO009- 9)06 u0 s.4w.e 101!£4_- rO O : yy�— :a Uj NOtIfliOS 1V3013H1• L 8 'ON T o 'UOIlew!Olu11eg4!rq i0] i lonpwd si4l]o esn pue Sea!US laags elep 00S .e �• �S•■ •,i� ` s� 0 01(9 1 9 511!panadde uo uo9awolw.1041n!10J luawiedap ao1n{a:lealu4oai mn(90)000. leeuem gugp/ado pue uopellelsul 00)aaS Pa1•01109 99990W suopanllsu!uonene;su!y1ON 01891'6400ST—)9 POI1WW �i y X71"1 V o s 'si0z'i-voszs s.UO3i 01 / y ,� - 3w !0000suol(IPuoo Isalld7 ,p c�olougoal Wf111Vtl']J q}lrA.$ulJlrA andlenouul Pup ' ...� ,` } II }i Q ona iNf11NV'O uol 010495 9191 apa Sul no 5901 woo ,�! 3 ' 30 �t9fE al A3O1OHH33131H€Olt'_-1N+ 3H1#O 31V1S NIO4F+K x-0!IAwO=,: ej ep 5141 .. .�M: rye"- 'z flu 2Jlem GouewJollad 55% 909196626[I 002C403 -'2'P3TEIS 031 991]'=i'-!Izi;300 r1Gr, P91Ps1 svtnno leauil lean-g pue-:AluelleM gonpold leaA j anlsnloul i ,� ,r * €4 34`JLS3A i1 379VI13N V 61141 snono]Wo0 u0 ($LZL9331 411M aauep,0aae ul p8el-11911 0,58+o do 0,05- onueladmaleelpoW Pe[1lmied 0004/0905 [ed] Pi nnd/4snd (0400017)Spe01.pwM pus ed OOba)-AAOUS.u$I]] O 89]]e8an1 oz 101 tll Wa,Fi0es000gmn�Lxe]y 0., J01 palllj683'2we]}..91011e Wniulwnle U34-UBIH ) sselt 6tates 0001 [Al 111A $ IIOA metsOs mnIH]zeW f LO 9 1i1 13HL 3Nti 3V3N1X3 I 1. L' aaxe4mdol' wlb'e31A1!len�j @jgeaael_L pue 109]014 aod5laH 'TASOiougaal 1A S5 [Oa] SOON 510121edwel]IelaullemdOI9-I N £9 C— ]NJ%] A d90Wap0IOUDa,nleledINSI � � Old I1LIV15o10u .,a l 4` 1 all !buy gtrtu,!}1]0095 plalh 0999} u0'4 8Z'O— 131%] II '°AWlua[a!ll600amlu,admal 500+ [N1%] 10 "Iloluap01a03ainleladmal 51 }` .. 19-0 *_* .1l 3 # (tyN€Y$ d[[91N!4N144fl 1:3. SlN3lDili3DD 3811108391931 'izlu0(9ooQT'O;SZ):510lllpu003j9ol uosueduno - 0ro ' o;•"u�q:w::mn'„'°.�'°.a in0Inei(aq alnleladwa}-pus ul suoglpuoc$009-pe°!1 001 45009 9091600094 a1npow Iealddj w n 4 )l-IA01 }uallaOXrd)a11M lagaeaM aq}]anagegm spjsIr1 lewlldp 61rrxuaaxvlatieal AN0111tiHP?.1.4l 44.0 3M-11Y 3A11 A0NNi Nlun000.)094sw/nu,10 doileslue8io ... .,. - salesS1110D94100S0)1006409100 r I I I i 941 417m 95110010000 w sailueilem IIn6- r: _ 609'61 of do 10 a1e:1-9oua!oltl.a ue pue'sGssejo sa0uvalol luawamseaW u!4l!mRlep py o s •.°�'=/eekgZ of do la00d leululou;o 5559 " lamod 1ay81q `SlSOO SOO ] M0] '0910 9001105 lad 0(911!lau�IH Vr z (08059 slea0OT 0(dn l0001 IOulwou s 1111�L1N13313 3(1,1.SQ`,){13S113R31(441 AJO111NH 311h18111iF'1t ---- O1 m 1e a sea /009 096 uo1 a ¢191 - ATE57 IIV' l F P � w -.- ' I ' %49'0 09-w J$118619116,4899 Is/4 . . ,00010$0 L____ . __3__ 1 m,et Suunp:amod 12-!.u(0.648610881(V 399451989191 M911V3ON9W80483a ;vNVHdYj&99N84t8Du83d 911331) j •SAep uawwus Jualo `joy Ua-se ii2M s4 a!19?6eiusa0lenler(e-sanlenle,idl) 10195101(?ads'130191119008c %Sv30N1%E=01Sseauei91oi1wivapseay9, OS'TW6wngaad,'0•SZzw/MOOUI, I u01jelpeJ Jos Ajlsuaju}-MO qtw9. aq uaijipuo i apun@3UW 100E OL'TE 59519 L0'L£ LAI d°'A .ddW1ea3e1IOA e a -x0�jad urpuexsn0 u�,a�laoe snyj 11i.�isap iegsnq-xis a pue slim lle� 091 09"L 92L 1S'L [V] """I ,d4W Ie1WSIJOO .8 50'8£ SLIP 55'LE. 0510 [A] °A +e9fllOA]piallOuadO a Itjjin3ji0 2J -aqj-jo-ajejs gjiML paUli{W0o uaaq MOu Set( jdanu0= 1190 a.Z'a 51'9 418 608 Im "I ,wOJINOI[na,q],agS 9oIPEOy-pa00aa-PIJ0Ms;wn1NV'O'a3ejans hews a uo a3u[≤w.1o;jad 4$6� 9 550 6'OSZ S LOS 0995 [MI "a"d zddWlela004 !!!t'1nalij:led saEq.e'ua g3iL M`914 o(0UL� aj, .1 e]t ...e 11, 'fl ahijehL3uUi.04 30N`SNOWON000NIlV83dOivL90NIV30NY519069 1511[W1NIW sassaidw!.511331)WCJJ alnpoW mos G -0 f m U 241 9615 9610 0612 1810 1%] if A3U81s0A 66£5 59'EE ZE'EE 86'ZE [A] -A .4419 le682110A IL. 996 09'6 95 6 ftl] d°"I +ddV R.Wa11Lq 9900 05'05 EI'0ti £8'6E [10 '°A .'aBvimAI2L31 Uad0 c I ! a r I OZ'01 171'01 6001 5001 IV] °$I JUSIM3 LAL3l ]1O 090 939 OZE 910 [Ml """d rddW 1918Mod (MO—i MO+3ON08310183MOd):OlS'SNOI110NOOJS3108VUNV1S1V 3ONVW80183d WOWINIW • 0£E 999 08£ SIE Ss.'1:]213MOd I T 8941 Put 5941'7019 l?£1000-!11019 lolaauuoa ww 001 I(—)'W W 0011.(+1;a)ge?68)05 zww 7 2(]103 W•�n,a sapolp ssedlq 441M'L9dl 15210 80l4Da5o1d . - wwIZ-£[zww0L-0g,0)1949-0L x0quogaun9 51103}leg 10105 Wl'11NV'0 awpPIsL10ouow OZ x,9 1193 wnlwwnle paslpoue Belo amelj wiq aj!sodwoo 1aagD 51388 Mojougaa4 uol4aagai-pue 9510 952)8 passalls-a/d dllewlay;ww Z E IUM3 00016 8h 1'81 1421aM (awes)8un 1pIOU1)ww9Ex ww 0009 X e WUJ9591 tmmj [O fl'Cl _ s e ,. w Aq pNod I Power Optimizer For North America P32 1 P3401! 370 I P400 I P401 j P405 / P485 / P505 Power Optimizer .'- For North America •• ' ' P320 P340 P370/ P400 / P401 / P405 / P485 ✓ P505 m INPUT Rated Input DC Powerm 320 340 370 400 405I 435 505 W Absolute h-larmurn InputVoltage 48 60 80 60 -125M 83"r Wf (vo at loweD temperature). h1PPTOperabng Range 8-48 8-60 8-80 8-60 12.5-105 12.5-83Vac 1 (� Maxrmurr:Short Circuit Current 11 10.1 11.75 11 14 Ado {I5 Maximum DC Input Current 13.75 125 14-65 125 175 Ado Wei4h ed Efficiency 99.5 weighted,Efioency 98.8 `+8.5 Onervoltage.Category I OUTPUT DURING OPERATION(POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER) Maximum Output Current 15 Ado Maximum Output Voltage 6D 85 ,Qc OUTPUT DURING STANDBY(POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTEROFF) Safety Output voltage per Power Optlmaer r 1 °Jdc STANDARD COMPLIANCE ■ EMC FCC ParttS Class 8,iEC61000-6-2;IEC610C-0-6-3 NSafety iEC62109-1(lass II safety),LIL1741 Material UL94 vv-[0,t1V Resistant m60H5. Yes INSTALLATION SPECIFICATIONS Maxmum Allowed Sys!≥m 1000 Vtic V6ftage Compatible inverters All SoiarEdgz Single Phase and Three Phase inverters DimensiormL5WSLXH) 129x153eD 5 5-1v6vll 129x153s33.S129v153x29.5 129x159x49.5/5.1h6.3a1.9- 129x162x59/ mm /5.1X x13 /S.tx6x1:16 S7 x6,4x 2.3 tin Weight(including cables) 630/1.4 75011.7 655/1` 845;14 1064/23 gr/ID Snaie or dual Input Corrector MC4r31 h+t=41n Input Wire Length 0.16/0.52 Output Wire Type!Connector Double Insulated,MC4 Output Wire Length 0.9./0.9i/2_95 J 1:2,13.9 m/ft PV power optimization at the module-level Operating Temperature Rangedm 4U-i85/-40-+185 / r Protection Rating IP68/NEMF6P Relative Humidity 0-i00 96 Specifically designed to work with SolarEdge I Fast installation with a single bolt (t;Rated power ofinemodolvatsrcwilr, em:eedrreopwoaz r•eamedr1PutDCPdrte•M lerninnuptnet%puwe toleranceareal!owed 121:555 2017 requees mom rnorm daee be netmo•e than 8LN inverters (3)Fro other cornecmtsr r.pes3ease cerraa SclarEdge I Next genera ton maintenance with module (4)Frmc`ual ersinnfaprallel t°"ne icr'ef"r'olnodeles use P485-4Ir.1DMRM.In the case of an aid nunber of CV modules in are sang ir.gallingo.ne P485 dualversm power opurnizercome d g rated Pvrrmlule Wren Snit ern e3 a single module seal the unused input ameadrs w th the aipplixJ pair of weals: I Up to 25%more energy level monitoring 151 Cut amt ent temCzaure ab re+35C(!185'Fpowr de-rating isapplied Refer to wer OptrruzmsTemrerature De-Ratinn Tednicrl rirtieierrnmedetelo I Superior efficiency(99.5x6) 1 Meets NEC requirements for arc fault �. , . . protection(AFCI)and Photovoltaic Rapid • • \�,1 I I l 1 f/ � I Mitigates all types of module mismatch losses, Shutdown System (PVRSS) Minimums?n Length F3211.P34C.P370. 2 10 1s ♦ �. A GoA // v 9 1=4j_ro.P4.1 � P� . 2, ii from manufacturing tolerance to partial (Poser optier cc) <C P405,P485,P505 6 8. 14 �,` _ 1.I C'•E s shading 1 Module-level voltage shutdown for installer F.aximumString.Length(PowerOpttmizers) 25 25 501°' ���•.� �� and firefighter safety 5,0316000v.th I * Na Maximum Puwer per String SE7600- SF 1400 5250 6000!'1 127501"1 W I Flexible system design for maximum space US-U51 !t • 374 :O utilization Parallel Strings of Different Lengths or Orierta0ons Yes y * O {o)r,x detailed s,ng mizire infotmaaen toter no h[y^�liwvFx.nolaredye°.aNs[esldeau[/files/nmrrg siung_ne pdf e 4 +� t7)r me ilowmd ter a e405/P485/P 05 Sets P32t/P340/P370/P4004401 in ale string ,���qs/J 10-A shiny with more than 30 opnrnizers does not meet NEC rapid shutdown regwrements salerysmltage will be above the 30V requirernnret {9)-Ft 208.`grd rt,s allrsxed to i sta,l up w s,5uGW per story white Ure mawm..m paNr tlilhrence between each snnu is l,Ly7uti i .•lot, C C—,v k s o I a r Y( t ( )Fc 2 /4A0v g id 4 rs 311ewedte nsall u m 15,000) per Nog mete rnanrcum pov r diCarence wi n Sad 3rinp rs Z000 1� W E( , t oR,DA t�, : solaredge.eom �' � A geOar5 CCogv Lra AJrAaht wtl 50 arrcet heiala.Fdgxl go,OC'97EDBY3IXgREb6Eare°adpmarl,x ,teed do hrte'rEAgeTa�doy trc. CVuo RoHS / O....... . � . 109 al an r dams-Ismmt"ne4nerercx Iaaeni.A�dthev�°PM ew ve rers.Dale n4nnzou^znrvc NArA smelled to rn•n9em e.tnan rhli,. Intertekf!1\\\: ISSUED FOR PERMIT 09-07-2020 ENGINEER CONTACT INFORMATION ENGINEERING STAMP CONTRACTOR CONTACT INFORMATION CONTRACTOR LOGO CUSTOMER: SHEET NAME: REV DESCRIPTION DATE ENGIPARTNERS, LLC TITAN SOLAR POWER FL FRAMONAAMADIS SMART MONITORING DATASHEET lo' Digitally sign PROJECT ADDRESS: C.A.32661 ;,s.,-OErsue.. by Rafael A 12221 N US HIGHWAY 301 * TITAN 255 GIRALDA AVE a 5835 11TH ST ?a>'cre Gonzalez Sot THONOTASASSA,FL 33592 ZEPHYRHILLS,FL 33542 PROJECT ID: ENGINEER OF RECORD: SHEET TITLE: CORAL GABLES,FL 33134 -Date: S 0 L A R P 0 W E R ENG.RAFAEL A.GONZALEZ SOTO,PE �twn�r : D-2 DESIGN@ENGIPARTNERS.COM c``•`.toRtoS`.� 2020.09.03 (813)982-9001 TSP50689 ' ' ` PARCEL NUMBER: DATE: SHEETS: "'%Sr'°';^„Ea•.' 08:00:57-04' 0' 11-26-21-0010-03600-0010 09-o,Q020 8 OF 9 786-393-4740 #EC13008093 Single Phase Inverter With H D-Wave Technology for North America Single Phase Inverter SE3000H-US SE3800H-US / SE5000H-US SE6000H-US Y SE7600H-US / SE1000OH-US / SE11400H-US with HD-".,.,' ... ave Technology for North America _ "' ` • SE3000H-US l SE3800H-US / SES000H-US / SESC6 000H-US � OUTPUT �+- �"�--+� -_•- 3800 @ 240V 6000 @ 240V i 1140.0 @ 240V VA SE7600H-US / SE10000H-US / SE11400H-US Rated AC PowerOutpuf 3000 5000 7600 10000 33OO©20811 5000©208V I 10Q00 @208V 208V Maximum AC Power Output 3000 3800 @ 240V 5000 6000 @ 24(i'J 7600 10000 k 11400 @ 240V VA 3300@ 208V 5000 @ 208V ' I 10000@ 208V —ULIR AC Output Voltaget,Ain.:Nom.-Max ✓ ✓ ✓ ✓ ✓ ✓ i .✓ Uac (211-240-264j (IS3-208-22tageMin.-Nom.-Max: ✓ _ A,Adjusltable-01.85t.' _ _ i ✓ Vac (183•208-229) AC-Frequency(Nom ina 9 HZ Maximum Continuous Output 12:5. 16 2Y32 1 42 i 47.5 A Current O240V Maximum Continuous Output - 16 - - - Current O208V $'f >m Power Factor .85 A q • GEDI Threshold A Utility Monitoring Islanding Protestloll Country Configurable Thresholds Yes INPUT Maximum DC Power @240V 4650 5900 7750 9300- 11800 i 15500 i 17650 W O Sofa '"'Fo"''•' Nb p ,..#• ?,. _ # Maximum DC Power @208V - 5100 - 1 7750 - - ; 15500 J W x .-r _ ,Y n' _ � ^ Transformer-les3 Ungrounded Yes r Q Maximum Input Voltage 480 Vdc Nominal DC Input Voltage 380 400 Vdc O imI Maximum Input Current @240V'I 8.5 1 10.5 135 1 16.5 20 27 ( 30.5 Aoc Maximum Input Current @208Vm - 9 - 13.5 27 Ads Max Input Short Circuit Current 45 Ads o 15 * S Reverse-Polarity Protection Yes ._ Ground-Fault Isolation Detection 600ka Sensitivity Maximum Inverter Efficiency 99 99.2 CEC Weighted Efficiency 99. 9S 5 @ 208V % Nighttime Power Convmption -r 2.5 W Optimized installation with HD-Wave technology e For other regional settings please crxltacr Solar Edge support CA higher current source may be used,the nnerta will limitit:input:a[rerltto the values stated I Specifically designed to work with power optimizers I UL1741 SA certified,for CPUC Rule 21 grid compliance I Record-breaking 99%weighted efficiency I Small,lightweight,and easy to install both outdoors or indoors I Quick and easy inverter commissioning directly from a smartphone using the SolarEdge SetApp guilt in module level monitoring \`'\e\�`,`A G0 , ,',, I Fixed voltage inverter for longer strings I Optional:Faster installations with built-in consumption metering(1%accuracy)and production revenue grade �, . S'..• c' B Integrated arc fault protection and rapid metering (O.5%accuracy,ANSI C12.2O) N shutdown for NEC 2014 and 2017,per article � * O 37®4 •• O 690.11 and 690.12 - o solaredge.com solar * i ;�l. %,��,��•. g a ISSUED FOR PERMIT 09-01-2020 ENGINEER CONTACT INFORMATION ENGINEERING STAMP CONTRACTOR CONTACT INFORMATION CONTRACTOR LOGO CUSTOMER: SHEET NAME: RAMONAAMADIS REV DESCRIPTION DATE ENGIPARTNERS, LLC Y PROJECT ADDRESS,Digitally TITAN SOLAR POWER FL INVERTER DATASHEET 9 CA.32661 ,o"yp�coeza�Frs,, Rafael signed by 12221 N US HIGHWAY 301 fT _'. T I T/""� ■ 255 GIRALDA AVE '4"�"� v"o.=Rafael A 5835 11TH ST 1 " THONOTASASSA,FL 33592 ZEPHYRHILLS,FL 33542 PROJECT ID: ENGINEER OF RECORD: SHEET TITLE: CORAL GABLES,FL 33134 =+' Gonzalez Soto D_3 ,rar�3F S 0 L A R P 0 IN E R ENG.RAFAEL A.GONZALEZ SOTO,PE `a3r•.F,oa,q.•Wps Date: DESIGN@ENGIPARTNERS.COM . _..... - (813)982-9001 TSP50689 - - rv".••' 2020.09.03 PARCEL NUMBER: DATE: SHEETS: " 08:01:05-0400 11-26-21-0010-03600-0070 09-01-2020 9 OF 9 786-393-4740 #EC13008093