Loading...
HomeMy WebLinkAbout20-1251 City of Zephyrhilis PERMIT NUMBER 5335 Eighth Street Zephyrhills, FL 33542 BNR-001251-2020 Phone: (813)780-0020 Issue Date: 01/14/2021 Fax: (813)780-0021 Permit Type: Building New (Residential) Propeyty N Street , Uiffiffra �W 32 25 21 0040 01400 0060 1 7097 Steer Blade Drive Owner liifgr—imatiInformation— I I I Contractor Information Name: D R HORTON Permit Type:Building New(Residential) Contractor: D R HORTON INC Class of Work:SFR Construct Address: 12602 Telecom Dr Building Valuation:$160,000.00 TAMPA,FL 33637 Electrical Valuation:$8,200.00 Phone: (813)549-1968 Mechanical Valuation:$6,000.00 Plumbing Valuation:$9,500.00 Total Valuation:$183,700.00 Total Fees:$14,770.94 Amount Paid:$14,770.94 Date Paid:1/1412021 1:40:20PM `��o�(-'dl Project jl[Os—aff,ji"QnIII CONSTRUCT SINGLE FAMILY 3,713 SQ FT SILVERADO Appl ication Mechanical Plan Review Fee $35.00 Building Permit Fee $830.00 Address Fee $30.00 Public Safety Impact Fee-Admin $26.35 Electrical Permit Fee $81.00 Plumbing Permit Fee $87.50 Electrical Plan Review Fee $40.50 Transportation Impact Fee $3,595.68 Building Plan Review Fee $415.00 Mechanical Permit Fee $70.00 Public Safety Impact Fee-Police $254.00 Plumbing Plan Review Fee $43.75 Driveway Fee $45.00 SIF 1 percent Fee $83.28 Transportation Impact Fee-City $36.32 School Impact Fee $8,328.00 Park Impact Fee-Single Familyrrownhome $769.56 REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each subsequent reinspection. Notice: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permit required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications add fee Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. CONTRACTOR SIGNATURE PE IT OFFICE[) PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER INVOICE1111 . • ' CITY OF BILLING CONTACT DAVID GLIDE D R HORTON INC / 12602 TELECOM DR TAMPA, FL 33637 INVOICE NUMBER INVOICE DATE INVOICE DUE DATE INVOICE STATUS INVOICE DESCRIPTION INV-00002426 01/11/2021 01/11/2021 Due NONE REFERENCE NUMBER FEE NAME TOTAL BNR-001251-2020 Address Fee $30.00 Building Permit Fee $830.00 Building Plan Review Fee $415.00 Driveway Fee $45.00 Electrical Permit Fee $81.00 Electrical Plan Review Fee $40.50 Mechanical Permit Fee $70.00 Mechanical Plan Review Fee $35.00 Park Impact Fee-Single Family/Townhome $769.56 Plumbing Permit Fee $87.50 Plumbing Plan Review Fee $43.75 Public Safety Impact Fee-Admin $26.35 Public Safety Impact Fee-Police $254.00 School Impact Fee $8,328.00 SIF 1 percent Fee $83.28 Transportation Impact Fee $3,595.68 Transportation Impact Fee-City $36.32 7097 Steer Blade Drive Zephyrhills, FL 33541 SUB TOTAL $14,770.94 REMITTANCE INFORMATION TOTAL $14,770.94 City of Zephyrhills 5335 8th Street Zephyrhills, FL 33542 January 11,2021 5335 8th Street,Zephyrhills,FL 33542 Page 1 of 1 41 CO COUNTY, FLORIDA Permit No. r z J t Date Permitted Z 7 guilder Name/Owner Name 4 Control# County Parcel No. 32 Z.,S Z!. Wit.pt q-00 OD60 SubDiv. —5JUerCJ QQ 1 ,�. Address/Locatlon 7 C q� 3�Y B)ccC�i�c_t~��'1, 1 ; ClasslflcadbnIType of UsQ TRANSFORTATION:IMPACT FEE . Rate: Sq.FtUnit: 3,713' Exempt Yes Q No How Determined Impact Fee Amount -$. t,t,32 Zone No. TAZ: SCHOOL-IMPACT-FEE Account (658) 'Single-Family Detached House Amount $ t (057) Mobileftme i (068). Other Residential Colle 123)_. ctiomi;ee Exempt �j Yes: Q No How Determined PARKS'AND.RECW TtON'FEE' Land Account Land Credit Land Total Recreation Account Recreation Credit Recreation;l'otat; . Zone TOTAL-AMOUNT $ . Exempt []'Yes ❑No How.Determined UBRi4ti i FEE Land Account Land Credit LandTotal Facility Account Facility Credit Facility Total Exempt ❑Yes Q No HowDetermined TotatAniountr::'. r RE 10URCE`PEE. ERU' TOTAL AMOUNT Prepared.By Ck _ Checked'Sy NO CERTIFICAT .:OF:OCCUPANCY-WI4L'BE I SUE0.':bR*jNAL;IN6PECTION. PERFORMED UNTILT{17t1 AMOt)N'[S.l:t$TED'.tfAVE RECEIPTED FOR BY:A CEN't`RAL:`PERMt7TIN0`:Ot FICE Ot?.PASCO,COUNTX Ackfft i*dgemant 1R10W.tloes onot Imply acceptance of concurrence,liuEsLnply reoelpt of a_copyr of ttUs fo r;placU►g - ` Uie titiitdlnp`p�simit wiu�on natlt�`of iltba assessrtient`arut.the`condlflonscf patent f6r sera:" . DATE RECEIVED.BY RECEIPT NO. DATE BY ~­v City of ZephVrhU ��� P8�� AopUCati F�0���2 OO � ao Building Department Date Recei�ed Phone Contact for Permitting 190 enyc�a i ac(V�CA ek or�m C-0 M ' T OwnerPhoneNu' be, ct, Owner's Name �QL - Owner's AddressFH-t,(am,' :t�:'JCCOMIY- 7-PADA 330�L Owner Phone Number 'Fee Simple Titleholder Name -sn yviz— Owner Phone Number Fee Simple Titleholder Address (OBTAINIED FROM PROPERTY TAX NOTICE) WORK PROPOSED NEW ADD/ALT SIGN DEMOLISH [��| INSTALL | \ REPAIR PROPOSED USE F--1 � aFR [—� COMM F--1 OTHER TYPE OFCONSTRUCTION - BLOCK �-� FRAME �--� STEEL ' =BV|LDING VALUATION OF TOTAL�—'�ELECTR|��L �--1 pROG�E8�ENEREY F-- VY�.E.�� -__' =PLUMBING �� =MECHANk}AL ON F--lG/V� ���' �]DF|Nn F—� � SPECIALTY OTHER OTHER FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YEo NO BUILDER COMPANY SIGNATURE REGISTERED LY/ N_ psI'-ouRREx LYLN_� Address P. Uuanen# ELECTRICIAN COMPANY SIGNATUREFC_0� I _y/ N I ' pssconmsN [_Y1 NL� Address Lioemee# PLUMBER COMPANY SIGNATURE Fo REG/STERED p0_Nl 'rssooR_R�t^ L)!/N� u' Auumms License# MECHANICAL F COMPANY &)-1,( 4� SIGNATURE REGISTERED , [��/lV_1 pEEconnsx -�,M,N_] . Address License# OTHER7 COMPANY SIGNATURE nea/orsnEo `A1N_ FEEouRRex 'I 'yiY�_�; Address Unonan# x u III x x x x m m u u x u m m x x m x n n1 u x n n u-x 1 K III u x n Kill u K u K o u x K 11 n n 11 u 11 m m x x x x x m KGG|OENTuUL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;F-O-W Permit for new construction, Minimum ten(1o)working days after submittal date. Required mnai0a.Construction Plans,Gtomnwoter Plans v/Slit Fence installed, Sanitary Facilities&1 dumpster,Site Work Permit for subdiAsions/large projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction. Minimum ten(1O)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Slit Fence installed, Sanitary Facilities&I dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(z)sets of Engineered Plans. ^°^°PROPERTYSURVEY required for all NEW construction, ' Fill out application completely, Owner m Contractor sign back nf application,notarized n over*usoo^a Notice o*Commencement|srequired. (AIo upgrades over$7n0o) � Agent(for the contractor)or Power of Attorne�(for the owner)would be someone with notarized letter from owner authorizing same ovER THE COUNTER pERMD � PERMITTING (copy of Romofs if shingles Sewers Service Upgrades A/C Fenmm(P|ot/Sumey/Fuotag6) Driveways-Not over Counter ifon public madwayo..nnodmROW ' NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to "deed" restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a -contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as.required by law, both the owner and contractor may be cited fora misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing.Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly.licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Fees'and Resource Recovery Fees must be paid prior to receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or final power.release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due, they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW (Chapter 713, Florida Statutes, as amended): If valuation of work is$2,500.00 or more, I certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the"owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner" prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: - Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands, Water/Wastewater Treatment. - Southwest Florida Water Management District-Wells; Cypress Bayheads, Wetland Areas, Altering Watercourses. - Army Corps of Engineers-Seawalls, Docks, Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. - US Environmental Protection Agency-Asbestos abatement. - Federal Aviation Authority-Runways. I understand that the following restrictions-apply to the use of fill: - Use of fill is not allowed in Flood Zone W"unless expressly permitted. - If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume" will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. - If the fill'material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction, I certify that fill will be used only to fill the area within the stem wall. - If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill, an engineered drainage plan is required. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells,. pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six(6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety(90) consecutive days, the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH-YGUR L-ENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.-­­- FLORIDA JURAT(F.S.117.03) OWNER OR AGENT CONTRACTOR Subscribed and sworn to(or affir d)befor me this Subscribed and sworn to(or affirmed)before me this byQul i p by Who is/are personally known to me or has/have prodtized Who is/are personally known to me or has/have produced as identification. as identification. Notary Public Notary Public Commission No. Commission No. Name of Notary typed,printed or st�d Name of Notary typed,printed or stamped °peg Notary Public State of Florida Michelle Moyes e c. My Commission GG 057321 or ci Expired 12/21/2020 D Q Single Family Dwelling Plan Review Comments 1. F.F.E.. shall be a minimum of 8" above the road elevation and an engineered site plan. 2. Lots shall be graded to comply with R401.3 of the F.B.C. 3: Compaction test required if 24"or more of fill dirt is brought in at any one.place. 4: Tie in survey required before pouring concrete. 5. Driveways require.a R.O.W. use permit. All 4 sides of driveway_ thru the sidewalk shall have expansion material. 6. All setbacks-shall be in et. 7: All.property markers shall be uncovered and marked at time of first inspection. 8. All A.D.A. requirernents shall be met:_ 9: No electric,.plumbing;mechanical, or framing shall be covered without an inspection and approval first. 10.All Garages shall comply with section�R302.6 of the F.B:C. (Fire Separation): 1.1. Appliances shall not be installed in a location where subject to mechanical damage unless protected by approved:barriers. M303.4 of the F.B.0 12. Water heaters shall comply with section P607.3 of the F.B:C.- 13. Foundation suliports for A/C units-shall.be raised at least 3" above finished grade. M1308.1 . 14. Return air in all bedrooms: F.B.C. M1620.4 1.5. Smoke detectors are to be installed in accordance with R313.1 of the F.B.C. 16.All glazing requirements are to be in accordance with R308.4 of the F.B.C. 17. All means of egress are to be in accordance-with R311 of the F.B.C. 18. "Green gypsum board" shall not be used as a backer in showers or tubs. R702A.2 F.B.C. 10. Combination-type AFCI breakers are required at all locations requiring an AFCI.type breaker. 20. Carbon monoxide alarms will be required in new construction that uses fossil-burning heating or appliances or an attached garage. They shall be installed in accordance with the F.B.C. 21. All plumbing, mechanical, and electrical shall he separate from unit to unit: This includes all underground.plumbing and.electric. 22: All 2016 N.E.C. Codes will be enforced: 23. Tamper-Resistant Receptacles in accordance with 406.11 of the 2016 N.E.0 24. In accordance'with the Land Development Code,lots shall be sodded before final at least 10 feet around the structure. 25: R403.5.3Hot water pipe insulation. Insulation for.hot water pipe With a minimum thermal resistance (-R-value) of R-3 shall.be applied to the following: Piping 31; inch (1.9.1 mm) and larger in nominal diameter._ Piping serving more than one dwelling unit. Piping located outside'the conditioned space. Piping from the W;titer heater to a distribution manifold: Piping located under,a floor slab. Buried in piping. Supply and return piping in recirculation systems other than demand recirculation-systems. 25. Blower.door'test shall be provided.before C.O: 26.A copy of the energy cacls shall be.with werniit at all times 27. Copy offnal insulation-report shall be provided with permit before fnah 28.1 No fence, pool or screen'enclosure Is issued with:this-permit RRE,Finished Floor Elevation F.B.C- Florida Building Code 6a'Edition R.O.W.-Right of Way A.D.A.=Americans with Disabilities Act N.E.C.-National Electric Code(2016) r' PLOT PLAN DESCRIPTION:(AS FURNISHED) LOT 6, BLOCK 14, SILVERADO RANCH SUBDIVISION PHASE 10A AS RECORDED IN PLAT BOOK 80, PAGE(S) 107-112, OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. Curve Table ON LOT CALCULATIONS LOT = 9.321 SO. FT. Curve/ Length Radius Delta Chord Bearing Chord LIVING AREA Z836 SO. FT. Ci 69.10' 270.00' 14'39'52' NO7'1X48'E 68.92' GARAGE = 619 SO. FT. ENTRY 65 SO. FT. C2 272.95' 30D.00' =r49' N255Y48'E 263.64' LANAI 193 SO. FT. C3 198.17' 300.00' 372T57' N33'1742'E 192.69, PATIO 0 SO. FT. DRIVEWAY = 630 SO. FT. C4 78.78' 300.00' 14'39'52' NO7-IX4S'E 78.5Y A/C PAD - 12 SO. FT. WALKWAY 23 SQ. FT. Una Table IMPERVIOUS = 47X 4378 SO. FT. a Una 0 Direction Length SOD = 4.943 SO. FT. L7 SOOT06'O8'E 24.41' OFF LOT CALCULATIONS RIGHT OF WAY = 1725 SQ. FT. z L2 524MS58'W 5.9Y DRIVE APRON = 374 SO. FT. 1" = 30' L3 N1813'OB'E 41.01' PUBLIC S/W = 471 SQ. FT. GRAPHICSCALE SOD = 880 SO. FT. I L4 NOD'08'OB'W 16.52' TOTALS 0 15 30 AREA = 11.046 SQ. FT. DRIVEWAY = 1,004 SO. FT. 'd' SIDEWALK = 494 SO. FT. SOD = 5,823 SO. FT. ~y m 00 -------------------1- ------------ --- m om s Z,.N89'53'52"E 115.00' � 'g I Ro I — — ---------------- -------o--- -- j J I t 75.0' / 75.00' 20!5' �a 41 Lj 12 �3 m a9 cl Re ::J:• i V i; a 84 0' I I g r �W tzYI - 1 0 o 16 - y 24.46, to ^ �� PREPARED FOR: BUILDING SETBACKS FRONT: ' 15 REAR: 15' a SIDE: 5' (50' LOTS) 7.5' (55' do 60' WIDTH LOTS) LEGEND: SIDE STREET: 15' —•— BUILDING SETBACK LINE PI POINT OF INTERSECTION NOTES: PC POINT OF CURVATURE CENTERUNE PT POINT OF TANGENCY 1. ELEVATIONS SHOWN ARE PER LOT GRADING —--— RIGHT OF WAY LINE RP RADIUS POINT PLANS PROVIDED BY THE CLIENT. ptX% PROPOSED ELEVATION PRC POINT OF REVERSE CURVATURE 2. ELEVATIONS ARE BASED ON NAVD 1988 TYP TYPICAL PCC POINT OF COMPOUND CURVATURE DATUM. PROPOSED DRAINAGE FLOW CS CONCRETE SLAB THIS PLOT PLAN IS INTENDED FOR PERMITTING PURPOSES r,•-.' CONCRETE CALCULATEDPER P) ONLY. THIS IS NOT INTENDED FOR THE CONSTRUCTION OF A/C AIR CONDITIONER PB PUT BOOK THE PROPOSED HOUSE. REFER TO HOUSE PLAN AND S/W SIDEWALK SO. SAGES 0. FT. SQUARE FEET OPTION LIST FOR CONSTRUCTION. ALL BUILDING SET BACK F.E.M.A. FEDERAL EMERGENCY MANAGEMENT AGENCY LINES SHOWN HEREON IS PER DATA FURNISHED BY CLIENT F.I.R.M. FLOOD INSURANCE RATE MAP AND IS FOR INFORMATIONAL PURPOSES ONLY. NAVD NORTH AMERICAN VERTICAL DATUM NGVD NATIONAL GEODETIC VERTICAL DATUM THIS IS NOT A SURVEY POEE PRIVATE DRAINAGE EADRAINAGE&UTILITY S1°ENTT THIS IS A PLOT PLAN ONLY UEE UTILITY UEAASLIEMENTTY PRIIVVATE) FLOOD NOTE: SURVEYOR NOTES: I HAVE EXAMINED THE RI.R.M.MAP NO.1210ICO288F, 1. THE SURVEYOR HAS NOT ABSTRACTED THE DATED SEPTEMBER 26,2014,AND FOUND THE SUBJECT PROPERTY LAND SHOWN HEREON FOR EASEMENTS, RIGHT APPEARS TO UE IN ZONE-X', AREAS DETERMINED TO BE OUTSIDE THE OF WAY RESTRICTIONS OF RECORD WHICH 0.21E ANNUAL CHANCE FLOOOPLAIN, THE SURVEYOR MAKES NO MAY AFI:'ECT THE TITLE OR USE OF THE LAND. GUARANTEES AS TO THE ABOVE INFORMATION. PLEASE CONTACT THE LOCAL F.E,M.A. AGENT FOR VERIFICATION. 2. NO UNDERGROUND IMPROVEMENTS HAVE BEEN BEARING BASIS: LOCATED EXCEPT AS SHOWN. BEARINGS SHOWN HEREON ARE BASED ON THE SOUTHWESTERLY LINE A5hA 3. NOT VALID WITHOUT THE AUTHENTIC OF LOT 6 BLOCK 14 BEING N7528'16-W,PER PLAT. ELECTRONIC SIGNATURE AND THE AUTHENTIC MERICAN ELECTRONIC SEAL OF A FLORIDA LICENSED (FIELD DATE:) REVISED: SURVEYOR AND MAPPER. SU RV EY I N G uey Dlgitallysignedby.1—INBoleman SCALE 1'— 30 FEET a, ... o $c MAPPING INC. ':° �''ltF DN:c=UICANSURVEING&M0. '�.o=AMERICAN SURVEYING&MAPPING, APPROVED BY: J13 INC,cn=James IN Boleman, CERTIFICATION OF AUTHORIZATION NUMBER LB/8393 9 srare�n ':d emall�bolema @asmco porate.comFOR 2WO47 LOT S.BLOCK 14 3181 MAGUIRE BOULEVARD, SUITE 200 k.,,,,,,,+�y Date:2020.11.1008:14:36.05'00' THE JOB NO. ORLANDO. FLORIDA 32803 '•'•'' Adobe Acrobat verslore11.0.23 FIRM DRAWN BY: RMB PLOT PLAN WWW.AMERICANSURVEYINGANDMAPPING.COM JAMES W. BOLEMAN PSM 6485 DATE 11-OS-2020 JSO