HomeMy WebLinkAbout20-1267 City of Zephyrhills IIIIIIIIIIIIP&E 0 u
_. 5335 Eighth Street
tm
Zephyrhills, FL 33542 BNR-001267-2020
fa Phone: (813)780-0020
I Fax: (813)780-0021 Issue Date: 01/21/2021
i
Permit Type: Building New (Residential)
Property Number Street Address
04 26 21 0120 00000 0300 6308 Bradford Woods Drive
Owner Information Permit Information Contractor Information
Name: PULTE HOME COMPANY LLC Permit Type:Building New(Residential) Contractor: PULTE HOME COMPANY
Class of Work:SFR Construct LLC
Address: 2662 Falkenburg S Rd Building Valuation:$119,749.00
RIVERVIEW,FL 33578 Electrical Valuation:$5,493.00
Phone: (813)964-5182 Mechanical Valuation:$5,145.00
Plumbing Valuation: 5 00
Total Valuation:$135,534.0.00 � ll
Total Fees:$14,055.68
Amount Paid:$14,055.68 •/ (J
Date Paid:1/21/2021 9:34:02AM
,P.roject Descrip "on
CONSTRUCT SINGLE FAMILY 2,399 SQ FT-OAKS OF PASCO
pplication Fees
Mechanical Permit Fee $65.72 Public Safety Impact Fee-Police $254.00
Public Safety Impact Fee-Admin $26.35 Electrical Permit Fee $67.46
Water Connection Residential Fee $1,010.00 Address Fee $30.00
Plumbing Permit Fee $65.74 School Impact Fee $8,328.00
Irrigation 314 Meter(Calc) $473.78 Electrical Plan Review Fee $33.73
SIF 1 percent Fee $83.28 Building Permit Fee $628.74
Sewer Connection Residential Fee $2,090.00 3/4 Water Meter Fee(Calc) $473.78
Mechanical Plan Review Fee $32.86 Plumbing Plan Review Fee $32.87
Driveway Fee $45.00 Building Plan Review Fee $314.37
REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c)the
local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or
first reinspection,whichever is greater,for each subsequent reinspection.
Notice: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that
may be found in the public records of this county, and there may be additional permit required from other governmental
entities such as water management, state agencies or federal agencies.
"Warning to owner:Your failure to record a notice of commencement may result in your paying twice for
improvements to your property. If you intend to obtain financing,consult with your lender or an attorney
before recording your notice of commencement."
Complete Plans,Specifications add fee Must Accompany Application.All work shall be performed in
accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O.
NO OCCUPANCY BEFORE C.O.
RAC OR SIGNATURE PE70 IT OFFICE
PERMIT EXPIRESIN 6 MONTHS WITHOUT APPROVED INSPECTION
CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED
PROTECT CARD FROM WEATHER
INSTR#2020215704 OR BK 10239 Pc 3838 Page 1 of 1
12/17/2020 11:50 AM Rcpt 2239073 Rec:10.00 DS:0.00 IT:0.00
Nikki Aivarez•Sowles,Esq.,Pasco County Clerk&Comptroller
permit No. Parce110No 04-26-21-0120-00000-0300
NOTICE OF COMMENCEMENT
stataof Florida County of Pasco
THE UNDERSIGNED hereby gives notice that improvement will be made to certain real property,and In accordance with Chapter 713,Florida Statutes,
the following Information Is provided In this Notice of Commencement
1. Description of Property:Parcel ldenraication No. LOT 0300 BLK 00000 Oaks of Pasco
Street Address: 6308 Bradford Woods Drive,LephyrhiUs,FL,33542
2. General Description of improvement New Construction-Single Family to include any construction of home.
pool,screen enclosure,deck,irrigation.water,sewer,and ALL other improvements.
3. Owner Information or Lessee Information t1the Lessee contracted forthe Improvement
Pulte Home Company,LLC
2662 S.Falkengurg Road Riverview FL
Address City State
Interest in Property: Fee Simple
Name of Fee Simple Titlaholdar.
Of different from Owner fisted above)
4. Contra&.. Pulte Home Company,LLC city state
No
2662 S.Talkenburg Road Riverview FL
Address city State
Contractor's Telephone No.: 813-964-5115
5. Surety: NIA
Name
Address City State
Amountof Bond:S Telephone No.:
S. Lender. N/A
Name
Address CIry State
Lenders Telephone No.:
7. Persons within the State of Florida designated by the owner upon whom notices or other documents may be served as provided by
Section?13.13(I)(a)C7),Florida Statutes:
NIA
Name
Address City State
Telephone Number of Designated Person:
a. In addition to himself,the owner designates N/A Ot—
to receive a copy of the Uences Notice as provided in Section 713.13(1)(b),Florida Statutes.
Telephone Number of Person or Entity Designated by Owner.
9. Expiration data of N011w of Comm nencemerd(the expiration date may not be before the completion of construction and final payment to the
contractor,but will he one year from live date of recording unless a different data o specified):
WARNING TO OWNER ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION O THE NOTICE OF COMMENCEMENT
CONSIDEREDARE PER IS UNDER SKP N71313 FLORIDA
CAN
N YOUR PAYING FOR IMPROVEMENTS TO YOUR ROPMTY. AN g OFCOMMENCMINit MUST
RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION.IF YOU INTEND TO OBTAIN FINANCING.CONSULT
WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT.
Under penalty of perjury,I declare chat 1 have mad the foregoing notice of commenamerd and that the fads state t mine W s to the best
of my knowledge and belief.
STATE OF FLORIDA
COUNTY OF PASCO
Sig natu r ssee,or sou Lessee's Authorized
dodPadrrerlManager
DIvision W of F.
Signatory's TgL-Mce
The foregoing Instrument was acknowledged before me this 16 day of December,202_0 by Matthew Hurd
as Attomey in Fact 11f.oGauthmay,e.g.,ofhcer•trustee,attorney in fact)for
Pulte Home Company.LLC (name of �/h behalf of*hom i erdwas executed).
Personally Known KI 4B Produced identification❑ Notary Signature
Type or Identification Produced Name(Print) Patricia Burchett
om�
517123urece
wpdatalbcslnogceoommencemenLpC053048
INVOICE1111
FOR OF
BILLING CONTACT
JODY SALTER r..
PULTE HOME COMPANY LLC
2662 FALKENBURG S RD
RIVERVIEW, FL 33578L . �_:_�
INVOICE NUMBER INVOICE DATE INVOICE DUE DATE INVOICE STATUS INVOICE DESCRIPTION
INV-00002415 01/11/2021 01/11/2021 Due NONE
REFERENCE NUMBER FEE NAME TOTAL
BNR-001267-2020 3/4 Water Meter Fee(Calc) $473.78
Address Fee $30.00
Building Permit Fee $628.74
Building Plan Review Fee $314.37
Driveway Fee $45.00
Electrical Permit Fee $67.46
Electrical Plan Review Fee $33.73
Irrigation 3/4 Meter(Calc) $473.78
Mechanical Permit Fee $65.72
Mechanical Plan Review Fee $32.86
Plumbing Permit Fee $65.74
Plumbing Plan Review Fee $32.87
Public Safety Impact Fee-Admin $26.35
Public Safety Impact Fee-Police $254.00
School Impact Fee $8,328.00
Sewer Connection Residential Fee $2,090.00
SIF 1 percent Fee $83.28
Water Connection Residential Fee $1,010.00
6308 Bradford Woods Drive Zephyrhills, FL 33542 SUB TOTAL $14,055.68
REMITTANCE INFORMATION TOTAL $14,055.68
City of Zephyrhills
5335 8th Street
Zephyrhills, FL 33542
January 11,2021 5335 8th Street,Zephyrhills,FL 33542 Page 1 of 1
Building Department
ate Received Z —ZZ Phone Contact for Permitting
-A-fl-lT-p-gam-p- --
. r r�
wner's Name PILLJk( U�'l C 00 N� x'u) LL G Owner Phone Number l C�� �� •�
J
F��lk�i�d�ur�' ( iV�rblli:�r� L
wner's Address 1 Owner Phone Number
!Q ,
�e Simple Titleholder Name / !4 Owner Phone Number
se Simple Titleholder Address !!'t
DB ADDRESS r Vl1l� �V G I� 536 LOT# D
UBDIVISION �D�;�S J�S�Cl PARCEL ID# D - a 'D�vt/"DODC,? ) O Dv
(OBTAINED FROM PROPERTY TAX NOTICE)
/ORK PROPOSED a NEW CONSTR R ADD/ALT SIGN Q DEMOLISH
INSTALL REPAIR
ROPOSED USE ® SFR. 0 COMM OTHER
YPE OF CONSTRUCTION `BLOCK [_] FRAME STEEL =
1ESCRIPTION'OF WORK
IUILDING SIZE SQ FOOTAGE HEIGHT _ 5116;0�A-
BUILDING I7,; VALUATION OF TOTAL CONSTRUCTION
=ELECTRICAL $ �`o� AMP SERVICE Q PROGRESS ENERGY 0 W.R.E.C.
1 f�
=PLUMBING $ l . 0 O
=MECHANICAL $ I VALUATION OF MECHANICAL INSTALLATION
0/1417
=GAS ROOFING Q SPECIALTY OTHER
7INISHED FLOOR ELEVATIONS /} n ! FLOOD ZONE AREA =YES NO
3UILDER COMPANY tale ��. �f�apm ,
SIGNATURE REGISTERED Y/ N FEE CURREN Y/N
Address ��S• 9 ! a V76(lea?,077.33T11?lLicense# L 67'a 44 Qf -
ELECTRICIAN COMPANY cJvG-da �GL° !G
SIGNATURE REGISTERED YIN FEE CURREN
Address SCc 1 h [a. TWO, a/J�z., [ n r
License# �C. 3C,0�7
PLUMBER COMPANY
SIGNATURE ,,/ �N, ,1 REGISTERED YIN FEE CURREN
Address 3133d 3-r"' ( / Jrl�� //F��l�7rg5" License
,,#,a
MECHANICAL COMPANY 17MY 6 '►'Y ((��L/(lDyllf f x �r//�
SIGNATURE REGISTERED Y/ N FEE CURREN LYINJ
R/3 i7Gr.Lti5Y7 d5tv1,�L 3�1�(v License# % % 3�7
Address Al /
OTHER COMPANY r- /"` ' C`�o /�`'G
SIGNATURE REGISTERED Y/ N FEE CURREN Y/N
/19I�iv/� �r e Git /cll /3 •L/3 �g '
Address i License# 3
00001a .0a1101afl00a0lAaaa1111II00a00a0111101111001190011811a010a100aa
RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction,
Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence Installed,
Sanitary Facilities&1 dumpster,Site Work Pen-nit for subdivisions/large projects
COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Fomns.R O-W Permit for new construction.
Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed,
Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance
SIGN PERMIT Attach(2)sets of Engineered Plans.
"*"PROPERTY SURVEY required for all NEW construction.
Directions,
Fill out application completely.
Owner&Contractor sign back of application, notarized
If-over$2500,a Notice of Commencement is required. (A/C upgrades over$7500)
*` Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same
OVER THE COUNTER PERMITTING (copy of contract required)
Reroofs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage)
Driveways-Not over Counter if on public roadways..needs ROW
D
Q 5�
•
Single Family Dwelling
Plan Review Comments
1. F.F.E. shall be a minimum of 8" above the road elevation and an engineered site plan.
2: Lots sliall.be graded to.comply with R401.3 of the F.B.C.
3:- Compaction test required if 24" or more of fill.dirt is brought in at any one place.
4: ,Tie in survey required before pouring concrete.
5: Driveways require a R.O.W. use permit. All 4 sides of driveway-thru the sidewalk shall have
expansion material..
6: All setbacks shall be met.
-7: All property markers shall be uncovered,and marked at time:of first inspection.
8: All A.D.A.requirements shall.be met.
.9: No electric,plumbing; mechanical, or framing shall.be_covered without an inspection.and
approval first.
10. All Garages shall-comply with section R302:6 of the F.B:I (Fire Separation):
11. Appliances shall not be installed in a location.where subject to mechanical damage unless
protected by approved barriers. M303A f-the F.B.0
12..Water heaters shall comply with section P607.3 of the F.B.C."
13. Foundation supports for A/C units shall be raised at least 3" above finished grade. M1308:1
14. Return air in all bedrooms. F.B.C. M1620:4
1-5. Smoke detectors are to be in in accordance with R313.1 of the F.B.C.
16. All glazing requirements are to be in' accordance with R308A of the F.B:C:
17. All means of egress are to be in accordance=with R3l l of the F.B.C.
18. "Green gypsum board" shall not be used as-a backer,in showers or tubs. R702.4.2 F.B.C. .
19. Combination-type AFCI breakers are required at all locations requiring an AFCI.type breaker.
20. Carbon monoxide.alarms will be required in new construction that.uses fossil-burning heating
or appliances or an attached garage. They shall be-installed in-accordance with the F.B.C:
21. All plumbing, mechanical, and electrical,shall be separate from unit to unit: This includes all
underground plumbing and electric.
22. All 20T6 M.E.C. Codes will be enforced:
23. Tamper- Resistant.Receptacles in accordance with 406.11 of the,2016 N.E.0
24. In accordance with the Land Development Code, lots shall.be sodded before final at least 10
feet around the structure:
25-.'R403.5.3Hot water.pipe insulation
Insulation for hot water pipe with a minimum thermal resistance (R-value) of R-3 shall.be applied to the
following:
Piping 3!. inch (19.1 mm)and larger in nominal diameter.
Piping,serving more than one dwelling unit.
Piping located outside the conditioned space:
Piping from the water heater to a distribution manifold:_
Piping.located under a floor slab..
Buried in piping.
Supply and return piping in recirculation systems other than demand recirculation systems.
-25.Blower door test shall be provided before C.O.
26. A copy of the enemy cacls shall be with permit at all times
27.. Copy of final insulation-redort shall be provided ivith permit before rina�
28. No fence, pool or screen-enclosure is issued with.this-permit.
F.F.E.-Finished Floor Elevation
F.B.C-Florida Building Code 6d Edition
R.O.W.-Right of Way
A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code(2016)
Building Department
Date Received Phone Contact for Permitting
EMI � r .22caa
Y n �" �d Owner Phone Number
Owner's Name . r FG• (. . �/ L• ��
Owner's Address , (r% rr./7j I' '� f Owner Phone Number
Fee Simple Titleholder Name Owner Phone Number
Fee Simple Titleholder Address WMA
JOB ADDRESS ,�r ��G,i� ) (�, .. ' -) 1i '� "/ LOT# . O3o
SUBDIVISION r'/f/, f. (/ PARCEL ID# 6 _6�1 40P cV -o'PO—v0®w V 3vv
(OBTAINED FROM PROPERTY TAX NOTICE)
WORK PROPOSED R NEW CONSTR R ADD/ALT 0 SIGN 0 Q DEMOLISH
INSTALL REPAIR
PROPOSED USE Q SFR 0 COMM OTHER
TYPE OF CONSTRUCTION. BLOCK 0 FRAME STEEL
DESCRIPTION OF WORK S JtZ �l /ZZ,1/0 1rrl
BUILDING SIZE f'/ �l'D/ SQ FOOTAGE pZ3% HEIGHT
'IK-1Z 7L IL 5L W CIE I Ec.AL q.M CEQ LL IL dL BE-E, k. 5E kart 3
BUILDING $ 11 q VALUATION OF TOTAL CONSTRUCTION
=ELECTRICAL Is 5 i%q , 190 AMP SERVICE 0 PROGRESS ENERGY Q; W.R.E.C.
=PLUMBING $ 6 i i 7,0
0
=MECHANICAL $ //�� Of� VALUATION OF MECHANICAL INSTALLATION
=GAS 0 ROOFING Q SPECIALTY 0 OTHER
FINISHED FLOOR ELEVATIONS /,�n `9),71 FLOOD ZONE AREA DYES NO
BUILDER COMPANY +i
SIGNATURE REGISTERED Y/N FEE CURREN Y/N
Address License#
ELECTRICIAN COMPANY
SIGNATURE REGISTERED Y/N FEE CURREN Y/N
Address License#
PLUMBER COMPANY
SIGNATURE REGISTERED Y/N FEE CURREN Y/N
Address License#
MECHANICAL COMPANY
SIGNATURE REGISTERED LZIN__j FEE CURREN Y/N
Address �) License#
OTHER COMPANY
SIGNATURE AREGISTERED Y/N FEE CURREN �Y/N �
Address rj I V�� License#
@Rag@:.gag@II1.9a aug`IE OttfaNil0% a-a itEi f3 fi ld6t tt3 00 ttizeggagfRI_@ oal
RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new.construction,
Minimum ten(10)working days after submittal date.Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed,
Sanitary Facilities&1 dumpster;Site Work Permit for subdivisions/large projects
COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction.'
Minimum ten(10)working days after submittal date.Required onsite,Construction Plans;Stormwater Plans w/Silt Fence installed,
Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance
SIGN PERMIT Attach(2)sets of Engineered Plans.
****PROPERTY SURVEY required for all NEW construction.
Directions:
Fill out application completely.
Owner&Contractor sign back of application,notarized
If over$2500,a Notice of Commencement is required.(A/C upgrades over$7500)
** Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same
OVER THE COUNTER PERMITTING (copy of contract required)
Reroofs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage)
Driveways-Not over Counter if on public roadways..needs ROW
ouuumg ueparrment
NOTICE OF DEED RESTRICTIONS:The undersigned understands that this permit maybe subject to"deed"restrictions"which maybe more restrictive
than County regulations.The undersigned assumes responsibility for compliance with any applicable deed restrictions.
UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES:If the owner has hired a contractor or contractors to undertake work,they
may be required to be licensed in accordance with state and local regulations.If the contractor is not licensed as required by law,both the owner and
contractor may be cited for a misdemeanor violation under state law.If the owner or intended contractor are uncertain as to what licensing requirements
may apply for the intended work,they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847-8009.
Furthermore,if the owner has hired a contractor or contractors,he is advised to have the contractor(s)sign portions of the"contractor Block"of this
application for which they will be responsible. If you,as the owner sign as the contractor,that may be an indication that he is not properly licensed and is
not entitled to permitting privileges in Pasco County.
TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands
that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings,change of use in existing buildings,or
expansion of existing buildings,as specified in Pasco County Ordinance number 89-07 and 90-07,as amended.The undersigned also understands,that
such fees,as may be due,will be identified at the time of permitting.It is further understood that-Transportation Impact Fees and Resource Recovery
Fees must be paid prior to receiving a"certificate of occupancy"or final power release.If:the projept does not involve a certificate of occupancy or final
power release,the fees must be paid prior to permit issuance.Furthermore,if Pasco County Water/Sewer Impact fees are due,they must be paid prior
to permit issuance in accordance with applicable Pasco County ordinances.
CONSTRUCTION LIEN LAW(Chapter 713,Florida Statutes,as amended):If valuation of work is$2,500.00 or more,I certify that I,the applicant,
have been provided with a copy of the"Florida Construction Lien Law—Homeowner's Protection Guide"prepared by the Florida Department of
Agriculture and Consumer Affairs.If the applicant is someone other than the"owner",I certify that I have obtained a copy of the above described
document and promise in good faith to deliver it to the"owner"prior to commencement.
CONTRACTOR'S/OWNER'S AFFIDAVIT:I certify that all the information in this application is accurate and that all work will be done in compliance with
all applicable laws regulating construction,zoning and land development.Application is hereby made to obtain a permit to do work and installation as
indicated.I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all
laws regulating construction,County and City codes,zoning regulations,and land development regulations in the jurisdiction.I also certify that I
understand that the regulations of other government agencies may apply to the intended work,and that it is my responsibility to identify what actions I
must take to be in compliance.Such agencies include but are not limited to:
- Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive
Lands, WaterNVastewater Treatment.
- Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering
Watercourses.
- Army Corps of Engineers-Seawalls, Docks, Navigable Waterways.
- Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment,
Septic Tanks.
- US Environmental Protection Agency-Asbestos abatement.
- Federal Aviation Authority-Runways.
I understand that the following restrictions apply to the use of fill:
- Use of fill is not allowed in Flood Zone W" unless expressly permitted.
- If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a
"compensating volume" will be submitted at time of permitting which is prepared by a professional engineer
licensed by the State of Florida.
- If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall
construction, I certify that fill will be used only to fill the area within the stem wall.
- If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent
properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating
the conditions of the building permit issued under the attached permit application, for lots less than one (1)
acre which are elevated by fill, an engineered drainage plan is required.
If I am the AGENT FOR THE OWNER,I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to
commencing construction.I understand that a separate permit may be required for electrical work,plumbing,signs,wells,pools,air conditioning,gas,or
other installations not specifically included in the application.A permit issued shall be construed to be a license to proceed with the work and not as
authority to violate,cancel,alter,or set aside any provisions of the technical codes,nor shall issuance of a permit prevent the Building Official from
thereafter requiring a correction of errors in plans,construction or violations of any codes.Every permit issued shall become invalid unless the work
authorized by such permit is commenced within six months of permit issuance,or if work authorized by the permit is suspended or abandoned for a
period of six(6)months after the time the work is commenced.An extension may be requested,in writing,from the Building Official for a period not to
exceed ninety(90)days and will demonstrate justifiable cause for the extension.If work ceases for ninety(90)consecutive flays,the job is considered
abandoned.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COM NCEMENT MAY RESULT IN YOUR
PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTE TO BTAIN FINANCING, CONSULT
,_1! "
FLORIDA JURAT(F.S. 117.03)
OWNER OR AGENT CONTRACTOR
ubs ribed and sw to(or affirm before 'sue / Subscribed and swom^(or affirmed)be f re me this
j I by 2G A&Z lll�tl� / by �t�o�-�17�_ /lD✓�f���-
Who is/are personally known to me or has/have produced Who is�onally.known to me or has/have produced
Ya",
as identification. as identification.
mmwtNotary Public 4441� / Notary Public
Comm'l(si No. Commission
P �
Name of Notary typed,printd9d or stamped Name of Notary typed,printed or stamped
PATRICIA BURCHETr
MY COMMISSION#GG365171 PATRICIA BURCHE17
D(PIRES:AUG 13,2023
r°rY�4A�o MY COMMISSION#GG365171
Bonded through 1 st State Insurance EXPIRES:AUG 13,2023
°F^ Bonded through 1st State Insurance
CI�TT OF EPHYRHILI�
"City of Pure Water"
5335 Eighth Street° Zephyrhills,Florida 33542-4312
(813)780-0000 o Fax(813) 780-0005
GENE WHITFIELD June 13,2018
Mayor
Mr.David Waronker
CITY COUNCIL 1420 Celebration Blvd., Suite 200
LANCE A.SMITH Celebration,FL 34747
Council President
Dear Mr.Waronker,
KENNMH M.BURGESS,JR
Vice President City of Zephyrhills Ordinance 1003-08, Section 12, Paragraph 5, provides that
planned unit developments (PUD) approved prior to September 30, 1988 are
CHARLES E.PROCTOR exempt from paying transportation impact, fees unless amended to permit
additional development that would generate traffic.
W.ALAN KNIGHT
The Silver Oaks PUP was approved on its third and final reading on January 11,
JODI WILKESON 1988, and therefore is exempt from paying transportation impact fees as stipulated
in Ordinance 100308 provided the original permitted number of dwelling units
remains the same.According to Todd Vande Berg, city planner,those numbers
within the Silver Oaks PUD have remained constant.
STEVEN F.SPINA
City Manager
Therefore,the Oaks at Pasco is exempt from paying these fees. A copy of
LORI L.HILLMAN Ordinance 1003-08.is provided for your information.The exemption and credits
City clerk,CMC section is located on page 10.
MATrBEW E.MAGGARD Sincerely,
City Attorney
Steven F, Spina,PhD
City Manager
cc: Todd Vande Berg, City Planner
Bill Burgess,Building Official
Matthew E. Maggard, City Attorney
PLOT PLAN
DESCRIPTION:(AS FURNISHED)
LOT 30, OAKS OF PASCO
AS, RECORDED IN PLAT BOOK 80, PAGE(S) 113-118, OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA.
ON LOT CALCULATIONS
LOT = 5,750 SQ. FT.
LIVING AREA = 1.860 SQ. FT.
GARAGE = 438 SQ. FT.
ENTRY = 21 SQ. FT.
LANAI = 90 SO. FT.
PATIO = 0 SQ. FT.
DRIVEWAY = 328 SQ. FT.
A/C PAD = 9 SQ. FT.
WALKWAY = 29 SQ. FT.
IMPERVIOUS = 48%
= 2775 SQ. FT. a
SOD = 2,975 SQ. FT.
OFF LOT CALCULATIONS
0
RIGHT OF WAY = 400 SQ. FT. z
DRIVE APRON = 57 SQ. FT. 1" = 30'
PUBLIC S/W = 250 SQ. FT. GRAPHIC SCALE
SOD = 93 SO. FT. 0 15 30
TOTALS
AREA = 6,150 SQ. FT.
DRIVEWAY = 385 SO. FT.
SIDEWALK = 279 SO. FT.
SOD = 3,068 SQ. FT.
a z
z
oa
a�
WQ
z�
J W W
I I X OWt1LL 6
W 1 O Z
� I
N 4W N
( ~ Xp O
} U) °S82'53'12'E Sg O 0o a s I o
3 1 __20.00'_ 90 J �a N
o - S82.53'1
0 2 cy
o = I" 0 2d5' 115.00' 9.1
_o r: ., . o
60.01
A/C -34.5'
0] I O 2 O rY
~ 7 W O CO)JO N ,^
Cc
J U Q 2O.S' S.3'U N 1 4 O0 Co
a ZI W ' 5.0'a OQWO O W— h / O �W W
QQ W o ( 5.3' aUZj v �¢ / F�-lai 3
`or I . `.. : / �s.o 00 O
a d 0-
LW 20.5' o UT
mo ~OO w�
Z
I�aF ?3 — N82 53'12»W — � -3
15.00'
PREPARED FOR: I tia
O) 9,• g0�0
�. CV
a � I
Ite j ;
BUILDING SETBACKS
FRONT: 20'
REAR: 10'
SIDE: 5'
SIDE STREET: 15'
LEGEND:
NOTES: — BUILDING SETBACK LINE PI POINT OF INTERSECTION
1. PROPOSED ELEVATIONS SHOWN HEREON ARE BASED — PC POINT OF CURVATURE
ON THE APPROVED ENGINEERING PLANS PREPARED CENTERLINE PT POINT OF TANGENCY
RIGHT OF WAY LINE RP RADIUS POINT
BY CORNELISON ENGINEERING & DESIGN INC. PRC POINT OF REVERSE CURVATURE
2. ELEVATIONS ARE BASED ON NAVD 1988 PROPOSED ELEVATION PCP PERMANENT CONTROL POINT
DATUM. TYP TYPICAL
PROPOSED DRAINAGE FLOW CS CONCRETE SLAB
THIS PLOT PLAN IS INTENDED FOR PERMITTING PURPOSES I (P) PER PLAT
CONCRETE (C) CALCULATED
CON
ONLY. THIS IS NOT INTENDED FOR THE CONSTRUCTION OF A/C AIR CONDITIONER PB PLAT BOOK
THE PROPOSED STRUCTURE. THE CONTRACTOR AND/OR PBS PAGES
OWNER ARE REQUIRED TO VERIFY ALL SETBACKS, BUILDING S/W SIDEWALK SQ. FT. SQUARE FEET
DIMENSIONS, AND LAYOUT SHOWN HEREON PRIOR TO ANY F.E.M.A. FEDERAL EMERGENCY MANAGEMENT AGENCY
CONSTRUCTION. F.I.R.M. FLOOD INSURANCE RATE MAP
NAVD NORTH AMERICAN VERTICAL DATUM
THIS IS NOT A SURVEY SSE SANITARY SEWER EASEMENT
DE DRAINAGE EASEMENT .. ..
THIS IS A PLOT PLAN ONLY uE UTILITY EASEMENT
FLOOD NOTE: 1 HAVE EXAMINED THE F.I.R.M. MAP NO. 12101CO452F - SURVEYOR NOTES:
DATED 09/26/2014 AND FOUND THE SUBJECT PROPERTY APPEARS TO UE S THE SURVEYOR HAS NOT ABSTRACTED THE
PARTIALLY IN ZONE'X' de'AE". ZONE 'X', AREAS DETERMINED TO BE 1.
OUTSIDE THE 0.2%ANNUAL CHANCE FLOOOPLAIN. ZONE'AE" AREAS LAND SHOWN HEREON FOR EASEMENTS, RIGHT
DETERMINED TO BE SPECIAL FLOOD HAZARD AREAS SUBJECT r 6 OF WAY, RESTRICTIONS OF RECORD WHICH
INUNDATION BY THE 19.ANNUAL CHANCE FLOOD EVENT, BASE FLOOD MAY AFFECT THE TITLE OR USE OF THE LAND.
ELEVATIONS DETERMINED TO BE 88.5'. THE SURVEYOR MAKES NO
GUARANTEES AS TO THE ABOVE INFORMATION. PLEASE CONTACT THE 2. NO UNDERGROUND IMPROVEMENTS HAVE BEEN
LOCAL F.E.M.A. AGENT FOR VERIFICATION. LOCATED EXCEPT AS SHOWN.
BEARING BASIS:
BEARINGS SHOWN HEREON ARE BASED ON THE CENTERLINE OF- 3. NOT VALID WITHOUT THE AUTHENTIC
BRADFORD WOODS DRIVE BEING N07-06'48'E, PER PLAT. A5MELECTRONIC SIGNATURE AND THE-AUTHENTIC
ELECTRONIC SEAL OF A FLORIDA LICENSED
(FIELD DATE:)
REVISED: A M E R I CA N SURVEYOR AND MAPPER.
1" = 30 FEET SURVEY 1 N G �„«�w o ,(Digitally signed by James W Bateman
SCALE: a 5:o,.H••.t DI c=US,st=Florida,I-0dando,
S& MAPPING INC.
�� ' -AMERICAN SURVEYING&MAPPING,
APPROVED BY: JB INC.,cn=James W Boleman,
CERTIFICATION OF AUTHORIZATION NUMBER LB#6393 5=t,s-ra a.'• —^email=boleman@asmcor orate.com FOR
x` 1 P
3191 MAGUIRE BOULEVARD, SUITE 200 ¢• =Date:2020.12.1513.01:20-05'00'
JOB NO. 191105 LOT 30 ORLANDO, FLORIDA 32803 ••••' �'•a,` AdobeAcrobaty sion:11.0.23 THE
' '" ';' FIRM
(407) 426-7979 -
DRAWN BY.' RMB PLOT PLAN 12 11 2020 JG WWW.AMERICANSURVEYINGANDMAPPING.COM JAMES W. BOLEMAN PSM# 6485 DATE
Men authonzalon mWadapWon by Comabon EroMiMing&Design,IroG(CM sh
ad bowMwut gab
i 4 I l� f
1 ~ m i
o �31 N j
� J- _�
4 ' `o
o
f �m N r 1
IQ
r is
ED
k So
!, d
ETC
to r
,�b
PROJECT NAME
D THE OAKS-AT PASCO
ED BY
ELAND BLVD-&SIMONS ROAD,ZEPWRHILLS,FLORIDA
Ab
PROJECT NAME
D THE'OAKS AT PASCO
ED BY
EOAND BLVD.&SIMONS ROAD,ZEPHYRHILtA FLORIDA
!_—
FZ
40
d ! I ! —I
� Am7d ! 31
(pan
AM
94NMI f
—
U is
82
79
\ 1
w
:PA5CO_COUNTY, FLORIDA
k' •
.47
r�r
Permit No.
i, Date Permitted
'Bullder,Name/OwnerName ,2,. i v1i;8 Control
County:Per'cel SubDiv: 0
Address/Locatlon3; V LL1 c!t
ClassiflcatloMypeof:.Usg c r:
TI AWPORTAMQICIMPACT FE fete: Sq.Ft Unit: ,399
Exempt (]Yes Q No How Determined
imppct Fee.Amourtt .$ Zone No. TAM
Accrount ;IMPACTFEE(056); Single*Famlly pstdohed House Amount $ „78 /1
° (067} Mobile;Moat#
Me). :0*11i'Resldential
dYei-"0146'
23) :Collectin Fee
Exempt How Determined
PA' RK$'ANt3 RECREATIONFEE
Lan1 Account Land Credit Land Total
ftdriatlon Account Recreation'Credit Recreation Total
Zone ., TOTAL-AmOUNT ''
Exempt Yes ( No How Detaunlned
LIBRAR. ME � ..—.
Land:Acdcunf . Land Crt3dlt Land Total
Facility Account Facility Credit Facility Total
II
Exempt ❑Yes ❑.No How Determined Total Amo 4
RESOURCE FEE ERU
TOTAL AMOUNT
Prepered-By r Checked By
NO.CERTIFICATE.`0F•.000.UPANCY WILL bF.ISSUED.'OR FINAL INSPECTION
PERT D r NTiL TH.*,T,-T. Is:AMb0isi ftt:ISTED HAVE
WON.PAIMAND.
RECEIPTED.FOR BY A CENTRAL PERMIT IWG'Od FICE•OF PASCO COUNTY
Ackr(owledgement below does not,imply aooeptanos of concurrence,but simply receipt of•a copq of this form,placing
the bWlftg paimit owner,on notice of this assesament'and the conditions of payment for some;
DATE -RECEIVED BY
RECEIPT NO. DATE BY