Loading...
HomeMy WebLinkAbout20-1268 City of Zephyrhills M P.,E R ft IT11 NUMBER 5335 Eighth Street Zephyrhills, FL 33542 BNR-001268-2020 Phone: (813)780-0020 Fax: (813)780-0021 Issue Date: 01/12/2021 Permit Type: Building New (Residential) Property Number Street 71111111 04 26 21 0120 00000 0620 6399 Bradford Woods Drive Owner Information IPermit Information Contractor Information Name: PULTE HOME COMPANY LLC Permit Type:Building New(Residential) Contractor: PULTE HOME COMPANY Class of Work:SFR Construct LLC Address: 2662 Falkenburg S Rd Building Valuation:$119,749.00 RIVERVIEW,FL 33578 Electrical Valuation:$5,493.00 Phone: (813)964-5182 Mechanical Valuation:$5,145.00 Plumbing Valuation:$5,147.00 l Total Valuation:$135,534.00 Total Fees:$14,055.68 Amount Paid:$14,055.68 Date Paid:1/12/2021 8:35:51AM Project Description CONSTRUCT SINGLE FAMILY 2,487 SQ FT OAKS OF PASCO Application I Fees Plumbing Plan Review Fee $32.87 Electrical Plan Review Fee $33.73 Plumbing Permit Fee $65.74 Sewer Connection Residential Fee $2,090.00 Water Connection Residential Fee $1,010.00 School Impact Fee $8,328.00 3/4 Water Meter Fee(Galt) $473.78 Electrical Permit Fee $67.46 Building Plan Review Fee $314.37 Mechanical Plan Review Fee $32.86 Public Safety Impact Fee-Admin $26.35 Building Permit Fee $628.74 Address Fee $30.00 Driveway Fee $45.00 SIF 1 percent Fee $83.28 Public Safety Impact Fee-Police $254.00 Mechanical Permit Fee $65.72 Irrigation 3/4 Meter(Calc) $473.78 REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each subsequent reinspection. Notice: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permit required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner:Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications add fee Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. 1� n �k T GNATURE PE IT OFFICE PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER INVOICE1111 FOR OF • BILLING CONTACT I JODY SALTER PULTE HOME COMPANY LLC 2662 FALKENBURG S RD RIVERVIEW, FL 33578 �^_1 INVOICE NUMBER INVOICE DATE INVOICE DUE DATE INVOICE STATUS INVOICE DESCRIPTION INV-00002358 12/31/2020 12/31/2020 Due NONE REFERENCE NUMBER FEE NAME TOTAL BNR-001268-2020 3/4 Water Meter Fee(Calc) $473.78 Address Fee $30.00 Building Permit Fee $628.74 Building Plan Review Fee $314.37 Driveway Fee $45.00 Electrical Permit Fee $67.46 Electrical Plan Review Fee $33.73 Irrigation 3/4 Meter(Calc) $473.78 Mechanical Permit Fee $65.72 Mechanical Plan Review Fee $32.86 Plumbing Permit Fee $65.74 Plumbing Plan Review Fee $32.87 Public Safety Impact Fee-Admin $26.35 Public Safety Impact Fee-Police $254.00 School Impact Fee $8,328.00 Sewer Connection Residential Fee $2,090.00 SIF 1 percent Fee $83.28 Water Connection Residential Fee $1,010.00 6399 Bradford Woods Drive Zephyrhills, FL 33542 SUB TOTAL $14,055.68 REMITTANCE INFORMATION TOTAL $14,055.68 City of Zephyrhills 5335 8th Street Zephyrhills, FL 33542 December 31,2020 5335 Sth Street,Zephyrhills,FL 33642 Page 1 of 1 INSTR#2020218893 OR BK 10243 PG 432 Page 1 of 1 12 22/2020 10:23 AM Rcpt 2240742 Rec:10.00 DS:0.00 IT:0.00 Nikki AlvarezSowles,Esq.,Pasco County Clerk&Comptroller Permit No. Parcel IDNo 04-26-21-0120-00000-0620 NOTICE OF COMMENCEMENT State of Florida county of Pasco THE UNDERSIGNED hereby gives notice that Improvement will be made to certain real property,and In accordance with Chapter 713.Florida Statutes, the following Information is provided in this Notice of Commencement: 1. Description of Property: Parcel Identification No. LOT 0620 BLK 00000 Oaks of Pasco Street Address: 6399 Bradford Woods Drive,Zephyrhills,FL,33542 2. General DasMplion of improvement__ New Construction-Single Family to include any construction of home. pool,screen enclosure,deck,irrigation,water,sewer,and ALL other improvements. 3. Owner Information or Lessee Information If the Lessee contracted for the improvement Pulte Home Company,LLC 2662 S.FalkenRurs Road Riverview FL Address City State Interest in Property: Fee Simple Name of Fee Simple Titleholder. (If different from Owner listed above) Address City State 4. Contractor. y Pulte Home Company,LLC 2662 SYaTalkenb=Road Riverview FL Address city State Contractors Telephone No.: 813-964-5115 5. Surety: N/A Name Address city state Amount of Bond: g Telephone No.: 8. Lender. N/A Name Address City State Lenders Telephone No.: 7. Persons within the State of Florida designated by the owner upon whom notices or other documents may be served as provided by Section 713.13(1)(a)(7),Florida Statutes: N/A Name Address City State Telephone Number of Designated Person: e. In addition to himself,the owner designates N/A of_ to receive a copy of the Llenoes Notice as provided In Section 713.13(1)(b),Florida Statutes. Telephone Number of Person or Entity Designated by Owner. 9. Expiration date of Notice of Commencement(the expiration date may not be before the completion of construction and final payment to the contractor,but will be one year from the date of recording unless a different date Is specified): WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT RESULTINIYOUR PAYINGPTWIPAYMENTS E FOR MPROVEMENTTSSPTO YOUR PROPIkRTY. A NOTIC9 FLORIDA F COMMENCEMENt MUST ee RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING.CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. Under penalty of perjury,I declare that I have read the foregoing notice of commencement and that the facts state rain a true to the best of my knowledge and belief. STATE OF FLORIDA is COUNTY OF PASCO Slgnat o r L8asee,or s or Lessee's Authorized OFficer ctor/Partner/Manager Division VP of Finan e Signatory's Thle/OfBce The foregoing Instrument was acknowledged before me this 2Lday of December,20 2g by Matthew Hurd as Attorney in Fact ( so uthority,e.g.,officer.trustee,attorney In feet)for Pulte Home Company LLC foam.or p behalf of whom In ment was executed). Personally Known®OR Produced Identification❑ Notary Signature Type of Identification Produced Name(Print) Patricia Burchett PAr�tIOW BOHCHETT * µY 00�trypS310 13,2 55171 B9fH�:N7813,2028 Beaded M,*1st Guts Imulilma wpdate/bes/neticecommencemenLpc053048 Building Department ate Received J 2 - � Phone Contact for Permitting —— 1 w nner's-Name t'" L;t+( tl o(Y)C N I 61.0 c. (,L Owner Phone Number J' wner's Address LL4,2 S' FG 14-1l bu_t-G' �1 i V��ii f t?(,t� L Owner Phone Number ?e Simple Titleholder Name Owner Phone Number Re Simple Titleholder Address" .l AC JB ADDRESS `! % /��Lv©© s G "�r✓� / 5 ��35 LOT# UBDIVISION dA;V's O ) PARCEL ID#I I — 6 __O r 0/�Q -,Woo r 0& (OBTAINED FROM PROPERTY TAX NOTICE) /ORK PROPOSED e NEW CONSTR 8 ADD/ALT SIGN = DEMOLISH INSTALL REPAIR ROPQSED USE ® SFR. 0 COMM C] OTHER YPE OF CONSTRUCTION BLOCK Q FRAME STEEL Q ESCRIPTION OF WORK IC LLJ L"C)�) fi (.�G�l SIB —��d'1!L �UILDING SIZE l_ SQ FOOTAGE HEIGHT =BUILDING $ f VALUATION OF TOTAL CONSTRUCTION =ELECTRICAL $ 3,00 AMP Ea SERVICE �;�P/R`OO� GRESS ENEERGY Q W.R.E.C. OPLUMBING $ =MECHANICAL $ 1�1 j- VALUATION OF MECHANICAL INSTALLATION =GAS O ROOFING Q SPECIALTY OTHER 'INISHED FLOOR ELEVATIONS ) FLOOD ZONE AREA OYES NO 3UILDER COMPANY NGNATURE REGISTERED Y/ N FEE CURREN Y/N Address �O���S% /C �� , �/ierJ�r�,33� License# ELECTRICIAN COMPANY c ka RGNATURE REGISTERED Y/ N FEE CURREN LILN Address License# E� CO 5 ' PLUMBER COMPANY SIGNATURE ,N, I REGISTERED Y/ N FEE CURREN YIN Address 3133/I�� "/.w J/�r/L�IGYif,FL�JL�7�� License# �ga73,177 MECHANICAL COMPANY SIGNATURE REGISTERED Y 1 N FEE CURREN R/'3 pewttV PV-,, a-5M,FL 3 q(,4a 7 License# 3 2� "Address OTHER COMPANY SIGNATURE REGISTERED Y/ N FEE CURREN lig3i�rv/' e�� Ft,3 " L L/3 5 Address i License# nQQaaQ .aneaaaAaaaaaQaQaalfaQ9itiSnaaaaa9910aaaIIaa 09a9a99aa10000a019000 RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster;Site Work Permit for subdivisions/large projects COMMERCIAL Attach(2)complete sets of Building Plans plus aLife Safety Page;(1)set of Energy Foams.R O-W Permit for new,construction. Minimum ten(10)working days after submittal date. 'Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster,Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. ****PROPERTY SURVEY required for all NEW construction. Directions: Fill out application completely. Owner&Contractor sign back of application,notarized If over$2500;a Notice of Commencement is required. (A/C upgrades over$7500) ** Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage) Driveways-Not over Counter if on public roadways..needs ROW D 1 . Q o� 4 Single Family Dwelling Plan Review'Comments 1. F.F.E. shall be a minimum of 8" above the road elevation and an engineered site plan. I Lots shall be graded to comply with R401.3 of the F.B.C. 3. Compaction test required if 24,,or-more of fill dirt is brought in at any one place. 4. Tie in survey required before pouring concrete. 5. Driveways require.a R.O.W. use permit. All 4 sides of driveway thru the sidewalk shall have expansion material. 6. All setbacks shall be met. 7. All.property markers shall be uncovered.and marked at time:of first inspection. 8. A11 A.D..A.requirements shall be met: 9. No electric,.plumbing;mechanical, or.framing shall be covered without an inspection and approval first. 10. All Garages shall comply with section R302.6 of the F.B.C. (Fire Separation). . 11. Appliances shall.not be 'installed in a location where subjed to mechanical damage unless protected by approved barriers. -M303A of the F.B.0 12. Water heaters shall comply with section P607.3 of the F:B.C: 13. Foundation supports for A/C units_shall be raised at least 3" above finished grade. M1308:1 14. Return air in all bedrooms. F.B.C. M1620.4 1-5. Smoke detectors are to be- installed in accordance with R313.1 of the' .F.B.C:. 16:All glazing requirements are to be in accordance with R308A of the F.B.-C: 17. All means of egress are to be-in accordance with R311 of the F.B.C. 18. "Green gypsum board" shall not be used as a backer in showers or tubs. R702A.2 E.B.C. 10. Combination-type AFCI breakers are required at all locations requiring an AFCI type breaker. 20. Carbon monoxide alarms will be"required in"new construction that--uses fossil-burning heating or appliances or an attached garage.-They shall be installed in accordance with the F.B.C: All plumbing,mechanical; and electrical shall be separate from unit to unit. This includes all underground plumbing and electric. 22. All 2016 N.E.C. Codes will be enforced: 23. Tamper- Resistant Receptacles in accordance with 406.11 of the.2016 N.E.0 24. Iri accordance with the Land Development Code,lots-.shall be sodded before final at least 10. feet around the structure. 25. R403.5.3Hotwater.pipe.insulation. Insulation for.hot,Water pipe.With.a minimum thermal resistance (R-value) of R-3 shall be applied to the following: -Piping-�i;inch (1.9:1 mm) and larger in.nominal diameter: Piping,serving more than;one dwelling unit. Piping located outside the conditioned space: Piping from the.water heater to a distribution manifold.- Piping.located under a floor slab: Buried in piping.: Supply and return piping in recirculation systems other than demand recirculation systems. -25.Blower door test shall be provided:before C.O: 26.A copy of the energy cacls shall be with Hermit at all times 27. Copy of finathisuldtio&ieport shall-be provided with permit before final 28..No fence,pool or screen enclosure :is issued with-this permit . F.F.E.-Finished Floor Elevation F.B.C=Florida Building Code 6t'Edition R.O.W.-Right of Way A.D.A.-.Americans with Disabilifies Act N.E.C.-National Electric Code(2016) MON speau••sAeMpeoi,ollgnd uo}I jejuno0 JOAO ION-sAeMaAIJa (a6ejaod/A9nmSAOld)s90118d OM sapelBdn eollues sigmas s916ulgs";l s;oolau (paimbei 1oellu0O;o Adoo) SNIllII111N3d HEINno3 3H1 ZI3AO awes 6ulzpoglne jeuMo w04 JO11a1 pazue;ou 411M auoawos aq pinoM(iauMo 841101)AawO)3tl IO'aMod'O 001024tJO0 aq;]0j);ua6tl (0081$JOAO sepej6dn O/y)•pajInbaJ sl;uawaouawwo0;0•03110N a 1009Z$JOAO 41 pazpelou 'uo1leolldde jO Moeq u61s jope11uo0 V iauMO 'Alalaldwoo uopeolldde}no.111d :su01138Jla S _ W i •uo11oni1suoo M3N Ile io;paimbei kamnS AINFIdMid...... •sueld p9J991J16u3}O slas(Z)WeRV lIWN3d N°JIS aouelldwoo jeew}snw sluawannbal lemewwoo py•sloalald Mau 11e 101}IwJsd VOAA a}IS•lelsdwnp I,.V saRllloed Aie;hies 'pe11e1sul 90ue:4 WS/M sueld JeWfAW101S'sueld uo1lonj;suOO'allsuo peiinba�1•ejap le111wgns 194e sAep bu1 AAA(01,)ua1 wnwlulUU -uo113nilsuoo mBu COI 11w'ad M O-d•suuOd A6Jau3}O}as(1,):a6ed A1ajeS ej!l a snid sueld 6u1P11n8;o slas alaldwoo(Z)g3eliV "IVlOa3WIN00 s}oafad 961e1/suOISIAlpgns 101}lwl9d TOM 911S:19}sdwnp 1.12 s911111Oecl tie;hies 'p911e1sul 90119A MS/M sueld la;eMwJOIS'sueld uollonilsuo0'allsuo pannbaU•a}ep le)Alwgns 19:4e sAep 6uppone(p I.)ua1 wnwlu111N 'uo11onilsum Mau 1011luu9d AN-0-8`swJOd MMEI101as(0!sueld 6ulpllne jo slas(Z)!sueld 101d(Z)40e11V W111N3alSMI I€DB90.R.RABaaBBa �i R aa -REcaaB139a $ R9ABEa -9a.D313a .32.9R9aa.sa it, D alldDa2Da10BB * O-.B@dl€ li . #asueoll \ag _ ssaJPPV ¢�1 N/A N3N8n0 333 N/A 03N31SlOE18 321n1tlNJIS �,/�1r1?1 L/ (�7>� , . /P/61,;. _F ANb'dW00 a3H10 #esueoll ssaippd N/A N3aanO 33d N/A a3N3isl93a 3ZInIVNJlS ANtldWOO 1VOINVHO3W #asueorl ssaipptl N/A N3NNno 33d N/A. a3N31SIJ3N 321n LtlNJIS ANtldWOO maawnld #esuaoll ssaJppy N/A N3NNno 33d N/A Q3N31S193N 31InitlNJIS kNVdUUOOF , - I Nb'IORIlO313. #asueoll ssaipptl N/A N3NNno 33d N/A a3N31s103N 3mniVNJIS 1' ANtldWOO m3aiine ON S3A0 H3NH 3NOZ 0001d �L1-0 SNOUVA313 MOO1d a3HSINld M31-110 AIIVIO38S SNIJOO-8 0 SVS= NOIIV'nt/1SN11VOiMdH03W d0 NOI1Hnlb'A On I f $ 1NOINVH03W0 //�� �j 0'3 2i'M 0 AMMEI SSBUS018d 0 301ANEIS dWb' 9(9 s" $ -1VOI 1103130 N0110ni31SNOO 1`d101 d0 NOIltln1HA � 7Ze $ JNlalln8= e ?, 3a3m m s 3e4a 131-b _?k Ta ?s h?z 3 �e`8 3a h9k? fi-h _ 1HJ13H Q 39b'l00d 0S �� / 3ZIS JNlallne �7. � � �� -,t5f' t�/• f �/ /JiJ/ /��,9 j��! 11210M d0 NOIldR10S3a 7 � Q 1331S �J 3Wb21d r Q / �>10018V 0 NOaon-d1.SNO3 10 3dAl z[2 / 1:19H10 — WW00 Q N3S 0 3Sn a3SOdOHd I� 2IWEIU IIV1SNl HSII0W30 Q NJIS 1Td/gab` RHISNOD M3N El a3SOdOMd MMOM (30LLON Xtll A 'dSdONd WONd Q3NItl190) #a11EIOMVd y �j ��r NOISIAlaens #l01 I.1.rC I ssamaatleor ssaippy japlogal311 aldwlS aad jagwnN au ogd JauMO / V aweN jaployal;Il aldwlS aad jegwnN auogd JaunnO 1 .,!! } ssaJPPV s,JauMO lagwnN auogd�aunnp '?� i/1 ) u'? 7 fo f aweN s,jaunnO 6u11.11waad.IOJ;oe;uo0 auogd 0 paAlaOON a;ed luewliedaa 6ulplln8 Dummy veNaiunen[ NOTICE OF DEED RESTRICTIONS:The undersigned understands that this permit may be subject to"deed"restrictions"which may be more restrictive than County regulations.The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES:If the owner has hired a contractor or contractors to undertake work,they may be required to be licensed in accordance with state and local regulations.If the'contractor is not licensed as required by law,both the owner and contractor may be cited for a misdemeanor violation under state law.If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work,they are advised to contact the Pasco County Building Inspection Division—Lid�.nsing Section at 727-847-8009. Furthermore,if the owner has hired a contractor or contractors,he is advised to have the contractor(s)sign portions of the"contractor Block'of this application for which they will be responsible.If you,as the owner sign as the contractor,that maybe an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACTIUTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings,change of use in existing buildings,or expansion of existing buildings,as specified in Pasco County Ordinance number 89-07 and 90-07,as amended.The undersigned also understands,that such fees,as may be due,will be identified at the time of permitting.It is further understood that.Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a"certificate of occupancy"or final power release,If.the project does not involve a certificate of occupancy or final power release,the fees must be paid prior to permit issuance.Furthermore,if Pasco County Water/Sewer Impact fees are due,they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713,Florida Statutes,as amended):If valuation of work is$2,500.00 or more,I certify that I,the applicant,' have been provided with a copy of the"Florida Construction Lien Law—Homeowner's Protection Guide"prepared by the Florida Department of Agriculture and Consumer Affairs.If the applicant is someone other than the"owner",I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner"prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT:I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction,zoning and land development.Application is hereby made to obtain a permit to do work and installation as indicated.I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction,County and City codes,zoning regulations,and land development regulations in the jurisdiction.I also certify that I understand that the regulations of other government agencies may apply to the intended work,and that it is my responsibility to identify what actions I must take to be in compliance.Such agencies include but are not limited to: - Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands, Water/Wastewater Treatment. - Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. - Army Corps of Engineers-Seawalls, Docks, Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. - US Environmental Protection Agency-Asbestos abatement. - Federal Aviation Authority-Runways. I understand that the following restrictions apply to the use of fill: - Use of fill is not allowed in Flood Zone W" unless expressly ptrrmitted. - If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume" will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. - If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction, I certify that fill will be used only to fill the area within the stem wall. - If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill, an engineered drainage plan is required. If I am the AGENT FOR THE OWNER,I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction.I understand that a separate permit may be required for electrical work,plumbing,signs,wells,pools,air conditioning,gas,or other installations not specifically included in the application.A permit issued shall be construed to be a license to proceed with the work and not as authority to violate,cancel,alter,or set aside any provisions of the technical codes,nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans,construction or violations of any codes.Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance,or if work authorized by the permit is suspended or abandoned for a period of six(6)months after the time the work is commenced.An extension may be requested,in writing,from the Building Official for a period not to exceed ninety(90)days and will demonstrate justifiable cause for the extension.If work ceases for ninety(90)consecutive days,the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER QR TORNEY—BEFORE REQORDING XQUILADII E COMMENCEMENT- FLORIDA JURAT(F.S. 117.03) OWNER OR AGENT A CONTRACTOR Subscribed ar�d swot g o rm e ore me this bscrib d wo ( r a i ed)b fore me this by 61� rL�'(.r/10ilS t. I y Who-is/are personally known to me or has/have produced Weds/are personally..known to me or has/have produced as identification. as identification. Notary Public �(/ Notary Public Comm' ion No. '4 6 _56J/ 7 / Commissior, r Narbe of Notary typed,printed or stamped Name of NotEiry typed,printed or stamped- PATRICIA BURCKTT ro PATRICIA BURCHETT = fin My COMMISSION#GG365171 z°tin My COMMISSION#GG265171 y EXPIRES:AUG 13,2023 EXPIRES:AUG 13,2023 �OF Bonded through 1st State Insurance � � Bonded through 1st State Insurance CITY OF ZEP 1tI-ILS ""City of Pure Water" f 5335 Eighth Street°Zephyrhills,Florida 33542-4312 (813)780-0000 Fax (813) 780-0005 GENE wHITFIELD June 13,2018 Mayor Mr.David Waronker CITY COUNCIL 1420 Celebration Blvd., Suite 200 LANCE A.SMITH Celebration,FL 34747 Council President Dear Mr.Waronker, KENNMH M.BURGESS,JR. Vice President City of Zephyrhills Ordinance 1003-08, Section 12, Paragraph 5, provides that planned unit developments (PUD) approved prior to September 30, 1988 are CHARLES E.PROCTOR exempt from paying transportation impact fees unless amended to permit additional development that would generate traffic. W.ALAN KNIGHT The Silver Oaks PUD was approved on its third and final reading on January 11, JODI wILKESON 1988, and therefore is exempt from paying transportation impact fees as stipulated in Ordinance 100308 provided the original permitted number of dwelling units remains the same.According to Todd Vande Berg, city planner,those numbers within the Silver Oaks PUD have remained constant. STEVEN F.SPINA City Manager Therefore,the Oaks at Pasco is exempt from paying these fees.A copy of LORI L.HILLMAN Ordinance 1003-08.is provided for your information. The exemption and credits City Clerk,CMC section is located on page 10. MATrBEw E.MAGGARD Sincerely, City Attorney Steven F, Spina,PhD City Manager cc: Todd Vande Berg, City Planner Bill Burgess,Building Official Matthew E. Maggard, City Attorney FASCO COUNTY, FLORIDA Permlt No. � Data Permitted �'Builder.Name/Owner. Name. �L[`f� _ ,�— Control#' County Parcel No. 2.b 2,6 g2, 66 ?e SubDIv: Address/Location Classlflcation/Type of Us@ - r TRANSPORTATION IMPACT FEE Rate: Sq:Ft Unit: Exempt .❑Yes Q No How Determined impact Fee Amount � Zone No. TAM SCHOOL IMPACT;FEE . . Account {656) SI`rigle=Famlly Detached House Amount $ � • (057) Moblte=Home (058) Ottiar,Resldentlal 123)" .Collection Fee ` Exempt Yes: Q No How Determined PARKS AND,RECREEATION FEE• Laird Account Land Credit Land Total Recreation Account Recreation Credit Recreation Total Zone TOTAL•AMOUNT $ l Exempt [}Yes Q No How Detelmined-70 `'.. LIBRAttYMEE ` Land Account Land-Credit Land Total Facility Account Facility Credit Facility Total j Exempt ❑Yes Q No How Determined Total AmountC:(�'" RESOURCE-FEE ERU TOTAL AMOUNT Prepared By t Checked By NO CERTIFICATE QF QCCUPANCY WILL BE ISSUED OR f INAL_INSPECTION PERFORMED UNTIL THE`TOTAL AM04NTS LISTED HAVE 8EEN'IAID AND RECGIPTED.FOR 9Y A CENTRAL:PERMITf'IN®OFFICE.OF PASCO COUNTY Acici"adgement below does not imply acceptance of concurrence,but simply recolpt of•a copy of thle form,placing the building permit owner on notice of this easessment and the conditions of payment for some. DATE RECEIVED BY RECEIPT NO. DATE BY PLOT PLAN DESCRIPTION:(AS FURNISHED) LOT 62, OAKS OF PASCO AS RECORDED IN PLAT BOOK 80, PAGE(S) 113-118, OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. ON LOT CALCULATIONS LOT = 5.750 SQ. FT. LIVING AREA = 1,850 SQ. FT. GARAGE = 438 SQ. FT. ENTRY = 45 SQ. FT. LANAI = 154 SQ. FT. PATIO = 0 SQ. FT. DRIVEWAY = 369 SQ. FT. A/C PAD = 9 SQ. FT. WALKWAY = 28 SQ. FT. IMPERVIOUS = 50% = 2893 SQ. FT. SOD = 2,857 SQ. FT. a OFF LOT CALCULATIONS RIGHT OF WAY = 394 SQ. FT. o DRIVE APRON = 57 SQ. FT. Z PUBLIC S/W = 250 SQ. FT. 1" = 30' SOD = 87 SQ. FT. GRAPHIC SCALE TOTALS 0 15 30 AREA = 6,144 SQ. FT. DRIVEWAY = 426 SQ. FT. SIDEWALK = 278 SQ. FT. SOD = 2,944 SQ. FT. o a I (0 ~� O go E S82•53'12,� s91a. 1pp• e I �Z O W3 1 o � o I Izs.a — z ir s� O ¢ to o I U¢¢ c0I W Ld s.0' . / ry p v W ¢ DO �i_ / �n > 3 �¢ d' ~ h� Q=x 6 a o0 2.7' 1 L ~O OIN2 O O�W .O O 1�� N 3'.. i O U a O J n Q O O 'L la10 Z V: N Z � 1— Co2F 5 .O : I IWiE 2 O I a=4 7 20.5'... �DO m Loa 31.8' A C 68.67• a N '.. :....e; OW 3V2 0 60.o I O : W � � N82'S3' 1' 9me 115,pp' 23.2' .0 w a I 12 B . 10 cc Q O I 9y5 N82.53'12'W -I U) C13 n W 0 1 20,DD• c ,16 µo (Cl Z � a O W F< I z I �' o a� N 1 PREPARED FOR: N Za o �W 0 oLL o OR 4o a a� e Xo 0.0 40 BUILDING SETBACKS FRONT: 20' REAR: 10' SIDE: 5' SIDE STREET: 15' LEGEND: NOTES: — BUILDING SETBACK LINE PI POINT OF INTERSECTION OINT OF CURVATURE 1. PROPOSED ELEVATIONS,SHOWN HEREON ARE BASED - CENTERLINE PC PPT POINT OF TANGENCY ON THE APPROVED ENGINEERING PLANS PREPARED _ _ — RIGHT OF WAY UNE RP RADIUS POINT BY CORNELISON ENGINEERING & DESIGN INC. PRC POINT OF REVERSE CURVATURE 2. ELEVATIONS ARE BASED ON NAVD 1988 PROPOSED ELEVATION PCP PERMANENT CONTROL POINT DATUM. TYP -TYPICAL PROPOSED DRAINAGE FLOW CS CONCRETE SLAB (P) PER PLAT THIS PLOT PLAN IS INTENDED FOR PERMITTING PURPOSES CONCRETE ) CALCULATED ONLY. THIS IS NOT INTENDED FOR THE CONSTRUCTION OF A/C AIR CONDITIONER (C(C PLAT BOOK THE PROPOSED STRUCTURE. THE CONTRACTOR AND/OR PGS PAGES OWNER ARE REQUIRED TO VERIFY ALL SETBACKS, BUILDING S/W SIDEWALK SQ. FT. SQUARE FEET DIMENSIONS, AND LAYOUT SHOWN HEREON PRIOR TO ANY F.E.M.A. FEDERAL EMERGENCY MANAGEMENT AGENCY CONSTRUCTION. F.I.R.M. FLOOD INSURANCE RATE MAP NAVD NORTH AMERICAN VERTICAL DATUM THIS IS NOT A SURVEY SSE SANITARY SEWER EASEMENT DE DRAINAGE EASEMENT - .. .. THIS IS A PLOT PLAN ONLY UE UTILITY EASEMENT.- FLOOD NOTE: I HAVE EXAMINED THE F.I.R.M. MAP NO. 1 21 01 00 452F SURVEYOR NOTES: DATED 09/26/2014 AND FOUND THE SUBJECT PROPERTY APPEARS TO LIE 1. THE SURVEYOR HAS NOT ABSTRACTED THE PARTIALLY IN ZONE "X' &'AE', ZONE 'X', AREAS DETERMINED TO BE OUTSIDE THE 0,29a ANNUAL CHANCE FLOOOPLAIN. ZONE'AE', AREAS LAND SHOWN HEREON FOR EASEMENTS, RIGHT DETERMINED TO BE SPECIAL FLOOD HAZARD AREAS SUBJECT TO OF WAY, RESTRICTIONS OF RECORD WHICH INUNDATION BY THE 1%ANNUAL CHANCE FLOOD EVENT, BASE FLOOD MAY AFFECT THE TITLE OR USE OF THE LAND. ELEVATIONS DETERMINED TO BE 88.5% THE SURVEYOR MAKES NO . GUARANTEES AS TO THE ABOVE INFORMATION. PLEASE CONTACT THE 2. NO UNDERGROUND IMPROVEMENTS HAVE BEEN LOCAL F.E.M.A. AGENT FOR VERIFICATION. LOCATED EXCEPT AS SHOWN. BEARING BASIS: BEARINGS SHOWN HEREON ARE BASED ON THE CENTERUNE OF A5M 3. NOT VALID WITHOUT THE AUTHENTIC BRADFORD WOODS DRIVE BEING N07'06'48'E, PER PLAT. ELECTRONIC SIGNATURE AND THE AUTHENTIC ELECTRONIC SEAL OF A FLORIDA LICENSED REVISED: �`�M E R 1 CAN SURVEYOR AND MAPPER. (FIELD DATE:) S U RV I�Y I N G 1' 30 FEET �°s�r DN:-U.-R. .1-0d eo, mw SCALE: "b IJ D 111 1 rt=Bariala,l- Sc MAPPING INC. �'°" k M A PING. N SURVEYING& - �ws�.a, MAPPING.LYC.ur-JamesW APPROVED BY: JB aemu,, CERTIFICATION OF AUTHORIZATION NUMBER L8�l6393 ,< �vo 7n@asmccrporale.com FOR 3191 MAGUIRE BOULEVARD, SUITE 200 % ,;;;,••° 'pale:zoza.rzla nsvaa-0sao THE JOB NO. 191105 LOT 62 ORLANDO, FLORIDA 32803 �� is Alone A"onac rerslon:"S'0(407) 426-7979 FIRM DRAWN BY: RMB PLOT PLAN 12 15 2020 JG WWWAMERICANSURVEYINGANDMAPPING.COM JAMES W. BOLEMAN PSM# 6485 DATE r` 74 85 84 62 --_ �87 S$ 90= 9 90 9 9,T3 2, _ 9 90 3,3 - J d i d i ; 65.; i i .,,63- i ! >g61 d a 60 o,59 d �s 58 FFI1'4d� = .1=9 F FF 1dd f P 26 4.52 ACRES 89 sD— PLOT PLAN DESCRIPTION:(AS FURNISHED) LOT 36, OAKS OF PASCO AS- RECORDED IN PLAT BOOK 80, PAGE(S) 113-118, OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. ON LOT CALCULATIONS LOT = 5,750 SQ. FT. LIVING AREA = 1,850 SQ. FT. GARAGE = 438 SQ. FT. ENTRY = 45 SQ. FT. LANAI = 154 SQ. FT. PATIO = 0 SQ. FT. DRIVEWAY = 371 SO. FT. A/C PAD = 9 SQ. FT. WALKWAY = 28 SQ. FT. IMPERVIOUS = 50% 2895 SQ. FT. SOD = 2,855 SQ. FT. a OFF LOT CALCULATIONS RIGHT OF WAY = 400 SO. FT. K DRIVE APRON = 57 SQ. FT. i PUBLIC S/W = 250 SQ. FT. 1" ='30' SOD. = 93 SQ. FT.TOTALS GRAPHIC SCALE AREA = 6,150 SQ. FT. 0 15 30 DRIVEWAY = 428 SQ. FT. SIDEWALK = 278 SQ. FT. C.) SOD = 2,948 SQ. FT. a I In a I � of � N I / S82'53'12'E �g12 0 I W 3 0/.--20.00' o �12_ �> S82.53 " o 20 o 62' IdE 115.00' � i wi S O¢ I N o I iv 51.0' o ¢ W 00 ir e pC�r 0 N. 0S . 0 rrlol d O ILI: N 20.5 v 6.0' O S.3' w-awZo- 1I3 U FWp o w9 o0:�w c0 w a Z a 2:y l . w a o - ca z4 Z 23.2' .. 68.67' / �'� F- to �� h 60.0' ICD O p Z j 6y9, N82•53'122)W 115. I � UU� g�a� egyy I _J V f 7 I \GQ� o PREPARED FOR: z��� o� �o� 0 k 0 :Ito L BUILDING SETBACKS FRONT: 20' REAR: 10' SIDE: 5' SIDE STREET: 15' LEGEND: NOTES: — BUILDING SETBACK LINE PI POINT OF INTERSECTION - 1. PROPOSED ELEVATIONS SHOWN HEREON ARE BASED — - PC POINT OF CURVATURE — CENTERLINE PT POINT OF TANGENCY ON THE APPROVED ENGINEERING PLANS PREPARED _ _ — RIGHT OF WAY LINE RP RADIUS POINT BY CORNELISON ENGINEERING & DESIGN INC. PRC POINT OF REVERSE CURVATURE 2. ELEVATIONS ARE BASED ON NAVD 1988 PROPOSED ELEVATION PCP PERMANENT CONTROL POINT DATUM. TYP TYPICAL PROPOSED DRAINAGE FLOW CS CONCRETE SLAB - ' THIS PLOT PLAN (P) PER PLAT INTENDED FOR PERMITTING PURPOSES CONCRETE (G) CALCULATED ONLY;-THIS IS NOTT INTENDED FOR THE CONSTRUCTION OF PB PLAT BOOK THE PROPOSED STRUCTURE. THE CONTRACTOR AND/OR A/C AIR CONDITIONER PGS PAGES OWNER ARE REQUIRED TO VERIFY ALL SETBACKS, BUILDING S/W SIDEWALK SO. FT. SQUARE FEET DIMENSIONS, AND LAYOUT SHOWN HEREON PRIOR TO ANY F.E.M.A. FEDERAL EMERGENCY MANAGEMENT AGENCY CONSTRUCTION. F.I.R.M. FLOOD INSURANCE RATE MAP NAVO NORTH AMERICAN VERTICAL DATUM THIS IS NOT A SURVEY SEE DSANITARY RAINAGE SEWERE EASEMENT THIS IS A PLOT PLAN ONLY UE UTILITY EASEMENT FLOOD NOTE: I HAVE EXAMINED THE F.I.R.M. MAP NO. 12101CO289F SURVEYOR NOTES: DATED 09/26/2014 AND FOUND THE SUBJECT PROPERTY APPEARS TO LIE 1. THE SURVEYOR HAS NOT ABSTRACTED THE PARTIALLY IN ZONE "X' &"AE". ZONE "X', AREAS DETERMINED TO BE LAND SHOWN HEREON FOR EASEMENTS, RIGHT DETERMIINEDETO BE SPECIAL FLOOD HAZARDPAREASZSUBJECT"TOREAS OF WAY, RESTRICTIONS OF RECORD WHICH INUNDATION.BY THE 1%ANNUAL CHANCE FLOOD EVENT, BASE FLOOD MAY AFFECT THE TITLE OR USE OF THE LAND. ELEVATIONS DETERMINED TO BE 88.5. THE SURVEYOR MAKES NO GUARANTEES AS TO THE ABOVE INFORMATION. PLEASE CONTACT THE 2. NO UNDERGROUND IMPROVEMENTS HAVE BEEN LOCAL F.E.M.A. AGENT FOR VERIFICATION. LOCATED EXCEPT AS SHOWN. BEARING BASIS: BEARINGS SHOWN HEREON ARE BASED ON THE CENTERLINE OF A5M 3. NOT VALID WITHOUT THE AUTHENTIC BRADFORD WOODS DRIVE BEING N07'06'48"E, PER PLAT. ELECTRONIC SIGNATURE AND THE AUTHENTIC ELECTRONIC SEAL OF A FLORIDA LICENSED REVISED: A M E FR I CAN SURVEYOR AND MAPPER. SCALE: 1 (FIELD DATE S U FRN/E Y I N CD ,osP:,4w:!�as� In Digitally signed by James W Boleman - �s DM—US,st=Florida,I=Orlando,, " = 30 FEET Q� �s`i•o"^uy;f —AMERICAN SURVEYING& APPROVED BY: 8c MAPPING INC. h JBF". rss+es } MAPPING,INC.cn=JamesW CERTIFICATION OF AUTHORIZATION NUMBER 1_B/J6393 B*mar%'jgoleman@asmcorpoote.com•. _ email=jboleman@asmcorporate.com FOR 3191 MAGUIRE BOULEVARD, SUITE 200 g•.,•`m•o,� THE JOB NO. 191105 LOT 36 ORLANDO, FLORIDA 32803 �.. Date:2020.12.0114:52:51-OS'00' "O�Aec '; `Adobe Acrobatversion:11.0.23 - FIRM (407) 426-7979 DATE DRAWN BY,. RMB PLOT PLAN 11 23 2020 JG WWW•AMERICANSURVFYINGANDMAP.PING.COM JAMES W. BOLEMAN PSM# 6485