Loading...
HomeMy WebLinkAbout5931 Gall Blvd (3)r 1] PHASE 2 TENANT FINISH A. ALL WORK SHALL CONFORM TO THE 6th EDITION OF THE FLORIDA BUILDING CODE (2017), AND ALL OTHER APPLICABLE CODES, STANDARDS, AND REGULATIONS OF THE CITY OF ZEPHYRHILLS, FLORIDA. B. IT IS INTENDED THAT A COMPLETE OCCUPIABLE BUILDING PROJECT IS PROVIDED. C. THE GENERAL CONDITIONS OF THE CONTRACT FOR CONSTRUCTION (A.I.A. A201 LATEST EDITION) ARE A PART OF THESE CONTRACT DOCUMENTS. A COPY IS ON FILE AT THE ARCHITECT'S OFFICE. D. DRAWINGS ARE BASED ON A SURVEY, DATED DECEMBER 1, 2015, PREPARED BY J.W. KENNEDY, AND IS INCLUDED IN THESE DOCUMENTS. E. DO NOT SCALE THESE DRAWINGS. VERIFY ALL DIMENSIONS AND CONDITIONS IN THE FIELD. ANY DISCREPANCIES IN THESE DRAWINGS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR TO STARTING WORK. F. ALL PROPOSED SUBSTITUTIONS SHALL BE APPROVED BY THE ARCHITECT, IN WRITING, PRIOR TO INSTALLATION. G. RETAIN THE PROJECT GEOTECHNICAL ENGINEER TO PROVIDE OBSERVATION AND TESTING SERVICES DURING THE GRADING (INCLUDING UTILITY TRENCHES) AND FOUNDATION PHASE OF CONSTRUCTION. ALL TESTING AND INSPECTION REPORTS, INCLUDING FINAL SUMMATION LETTER, SHALL BE SUBMITTED TO THE BUILDING DEPARTMENT AND OWNER. H. SUBMIT, PAY FEES AND OBTAIN ALL PERMITS ASSOCIATED WITH THE PROJECT EXCEPT GENERAL BUILDING PERMIT. THIS INCLUDES, BUT IS NOT LIMITED TO ELECTRICAL, MECHANICAL, PLUMBING, FIRE SPRINKLER, OR OTHER RELATED FIRE PERMITS. ZEPHYR, LLC WILL PAY FOR "CONNECTION FEES" ASSOCIATED WITH UTILITY PERMITS. PAY FOR TEMPORARY FACILITIES FEES AS REQUIRED TO COMPLETE THE WORK IN A TIMELY MANNER. I. PROVIDE EACH SUBCONTRACTOR WITH A COMPLETE AGENCY -PERMITTED DRAWING SET AT TIME OF CONSTRUCTION. J. ALL ABBREVIATIONS INCLUDED FOLLOW INDUSTRY STANDARDS. CONTACT ARCHITECT IF ANY ABBREVIATIONS ARE NOT CLEAR. K. GC SHALL SUPPLY AND INSTALL ALL ASPECTS OF THE PROJECT DESCRIBED IN THIS DRAWING SET UNLESS OTHERWISE NOTED. SEE SCOPE OF WORK FOR EXCEPTIONS. L. GRAPHIC AND WRITTEN INFORMATION ON DRAWINGS SHALL BE COORDINATED WITH ALL TRADES PRIOR TO INSTALLATION. M. ALL MATERIALS STAGED TO BE USED FOR CONSTRUCTION SHALL BE PROTECTED FROM EXCESSIVE MOISTURE. IF THEY ARE EXPOSED TO MOISTURE THEY SHOULD BE ADEQUATELY DRIED BEFORE ENCAPSULATED INTO THE BUILDING. N. THE GENERAL CONTRACTOR SHALL ALLOW DOLLAR GENERAL VENDORS TO CONDUCT ON -SITE REVIEWS OF PROGRESS AT VARIOUS TIMES. 0. GENERAL CONTRACTOR SHALL PROVIDE WEEKLY CONSTRUCTION PROGRESS REPORTS TO THE OWNER, TENANT, AND ARCHITECT. P. THE GENERAL CONTRACTOR SHALL COORDINATE WITH THE OWNER FOR ACCESS TO THE CENTRALLY LOCATED KNOX BOX AND PROVIDE A KEY TO THE FIRE MARSHAL. Q. THE GENERAL CONTRACTOR SHALL PROVIDE 6" ADDRESS NUMERALS VISIBLE FROM THE ROADWAY. VERIFY ACCEPTABILITY OF LOCATION WITH THE FIRE MARSHAL. R. THE GENERAL CONTRACTOR SHALL PROVIDE MIN. 4" ADDRESS NUMERALS ON ALL FRONT AND REAR DOORS. S. THE GENERAL CONTRACTOR SHALL OBTAIN THE SERVICES OF A LICENSED FIRE SPRINKLER ENGINEER TO PROVIDE ANY MODIFICATIONS TO THE EXISTING SYSTEM THAT MAY BE REQUIRED, DUE TO THE RECONFIGURATION OF THE SPACES. SHOP DRAWINGS OF ANY IMPROVEMENTS SHALL BE PROVIDED TO THE OWNER AND TO THE LOCAL JURISDICTION FOR APPROVAL PRIOR TO COMMENCEMENT OF WORK ON THE FIRE SPRINKLER SYSTEM. PROJECT GENERAL NOTES NAME ROOM NAME X =ELEV. ELEV. LETTER 1 AX. SHEET SHEET NUMBER O DOOR NUMBER 4 OAX.X2 _� ELEVATION NUMBER WINDOW NUMBER / DECOR ITEM NUMBER 3 ❑X EXTERIOR WALL FINISH NUMBER CEILING HEIGHT O KEY NOTE BLDG. SECTION LETTER X-000 EQUIPMENT NUMBER X Ax.x XX ROOM FINISH NUMBER BLDG. SECTION SHEET � INTERIOR ELEVATION DESIGNATION DETAIL NUMBER X —DIRECTION OF DETAIL AX.X ID SHEAR WALL TYPE (STRUCTURAL) DETAIL SHEET Q REVISION NUMBER XXX 000 EQUIPMENT / FIXTURE NUMBER (M.E.P.) 014a. BLDG. HEIGHT INDICATES SUSTAINABLE DESIGN ELEV REFERENCE POINT GREEN REFER TO STRUCTURAL, MECHANICAL, PLUMBING AND ELECTRICAL SHEETS FOR SPECIFIC SYMBOLS GENERAL DRAWING SYMBOLS PROJECT LOCATION �f 3 tea,. VICINITY MAP TYPE II B BUILDING AREA AND OCCUPANT LOAD TYPE AREA FACTOR STORAGE/STOCK/SHIPPING 2982 S.F. 1:300 GROSS GRADE FLOOR AREA (MERCANTILE) 10644 S.F. 1:60 GROSS OCCUPANTS 10 177 TOTAL 187 OCCUPANTS PLUMBING FIXTURE CALCULATION WATER CLOSETS LAVATORIES DRINKING FOUNTAIN SERVICE SINK REQ./ ACTUAL REQ / ACTUAL REQ./ACTUAL REQ. / ACTUAL MEN 1/3 1/4 1/2 1/1 WOMEN 1/5 1/3 TENANT FINISH OF AN INLINE MERCANTILE SPACE. REFER TO CIVIL DRAWINGS. PROJECT SUMMARY PROJECT DESCRIPTION LEGAL DESCRIPTION OWNER ARCHITECT ZEPHYR, LLC L.B. MANSKE ARCHITECTURE & DESIGN, INC. 7162 READING ROAD, STE 730 LEE B. MANSKE, AIA, NCARB CINCINATTI, OH 45237 2422 N. RUTGERS COURT WICHITA, KS 67205 316.749.5873 MECHANICAL ENGINEER ELECTRICAL ENGINEER ENGINEERING PROFESSIONALS, INC. PMD ENGINEERING 1717 N. HOWARD AVENUE 6117 SCHOOL HOUSE COURT, STE 200 TAMPA, FLORIDA 33607 WESLEY CHAPEL, FLORIDA 33545 813.251.6848 813.322.4373 CIVIL ENGINEER CORNELISON ENGINEERING & DESIGN, INC. 38039 OLD 5TH AVENUE 33542 813.788.7835 PROJECT DIRECTORY TITLE/SITE T1.0 TITLE SHEET ARCHITECTURAL A1.0 FLOOR PLAN A2.0 SCHEDULES A3.0 OFFICE PLAN AND ELEVATIONS ACCESSIBILITY ADA1.0 ACCESSIBILITY REQUIREMENTS MECHANICAL M1 MECHANICAL FLOOR PLAN M2 MECHANICAL SCHEDULES & DETAILS ELECTRICAL EMS1 LOW VOLTAGE PLAN E1 POWER & DATA FLOOR PLAN E2 LIGHTING AND EQUIPMENT FLOOR PLAN E3 DATA CABLING PLAN E4 PANEL SCHEDULES iZ DATE: G �7 l g�Il.nINC OF Fcl ICTA L vL SHEET INDEX "GI OONT( �, T DATE: U�L®1 TYPE: i N VERSION: SITE NUMBER: STORE NUMBER: 0 Q 0 z w z w U J Q 0 J U- w Y z Q CO w w J 08.01.2018 N/A N/A N/A N/A TENANT FINISH GALL BLVD ZEPHYRHILLS, FL 33541 FINISH PLAN PHASE 2 TITLE SHEET T1.G PLOT DATE: 4 1O EXISTING DOOR TO REMAIN. SEE PHASE 1. O2 EXISTING WALL SHOWN HATCHED. OEXISTING SHELL WALL SHALL REMAIN SEE PHASE 1. DO NOT DAMAGE SUBSTRATE OR REMOVE INSULATION. ® INFILL OPENING OF PREVIOUSLY DEMOLISHED DOOR WITH METAL STUDS AND SUBSTRATE TO MATCH EXISTING WALL THICKNESS. O NEW 3-5/8" METAL STUD WALL WITH STUDS SET AT 12" O.C.. EXTEND TO ROOF DECK. PROVIDE NEW BOX HEADER (PAIR 6" X 14 GA. (1-5/8" FLANGED AT ROUGH © OPENING HEIGHT. cD EXISTING COLUMNS TO REMAIN. PAINT COLUMNS SW#7005 "PURE WHITE". WRAP BOTTOM OF COLUMN WITH BLACK, SHORT -PILE CARPET TO 48" A.F.F. ® PROTECT STOREFRONT AND GLAZING DURING CONSTRUCTION. O PAINT P-3 ABOVE 1 G-0". PATCH AND REPAIR CONCRETE FLOOR AS REQUIRED TO PROVIDE A LEVEL 10 SURFACE THROUGHOUT THAT IS READY TO ACCEPT NEW FINISHES AS SCHEDULED. 11 INSTALL 2" MCCUE CORNER GUARD ON ALL SALES FLOOR OUTSIDE CORNERS. 12 LOW WALL. INSTALL 6" STEEL STUDS AT 12" O.C. TO 5'-0" A.F.F. CAP WITH 1/2" BLACK SOLID SURFACE MATERIAL SELECTED BY GENERAL CONTRACTOR. 13 INSTALL 1/2" SOLI.Q SURFACE SILL AT ALL INTERIOR WINDOW SILLS. MATERIAL SELECTION 13R GENERAL CONTRACTOR. 14 IN%I_ WALL AREA WITH STUDS AND SUBSTRATE TO MATCH EXISTING SURROUNDING WALL MATERIALS. 15 INSTALL MCCUE RAILING AS SHOWN IN FRONT OF PANELS. INSTALL TO 4'-0" HIGH WITH TOP AND MIDDLE POST, INSTALL 2" ALUMINUM CORNER GUARDS AT ALL RECEIVING AREA OUTSIDE 16 CORNERS. PROVIDE AS -BUILT SET OF PLANS ROLED INTO PVC TUBE ABOVE INTERIOR OF 17 OFFICE DOOR. PROVIDE NEW 1/2" GYPSUM BOARD SUBSTRATE ON ALL NEW WALLS. VERIFY SUBSTRATE IS APPLIED TO ALL EXTERIOR WALLS AS CALLED FOR IN PHASE 1. 18 ALL NEW AND EXISTING WALL AREAS SHALL BE TAPED, BEDDED, SANDED SMOOTH, AND PRIMED WITH NEW CONSTRUCTION PRIMER ... READY FOR PAINT. 19 PROVIDE SOUND BATT INSULATION IN ALL INTERIOR FACING RESTROOM WALLS. 20 BUILDING EXTERIOR NOT IN SCOPE. REFER TO PHASE 1 DRAWINGS. 21 ADJACENT TENANT: OLLIES BARGAIN BARN. 22 EXISTING SLAB. 23 EXISTING TRANSFORMER KEY NOTES N/A I B PROVIDE AND INSTALL 2x6 AT 78" A.F.F. AND 2x4 AT 12" A.F.F. WHITE PINE - GRADE 2 OR BETTER ALONG ENTIRE LENGTH OF WALL THAT SODA FIXTURES ARE LOCATED ON, TYPICALLY STARTING AT END OF LAST COOLER/FREEZER. VERIFY EXACT LOCATION OF SODA FIXTURES WITH FINAL FIXTURE LAYOUT. P1 SHERWIN WILLIAMS SW6910 "DAISY YELLOW' OSHERWIN WILLIAMS P2 SW6991 " BLACK MAGIC' P3 SHERWIN WILLIAMS SW7005 " PURE WHITE" m FLOM PLAN 1 /4®=1'-o9 A 0 v rn Q O z w cn z w U rQ 0 Ir O J w Y Z Q 00 w w J 16009 0 0 0 0 0 0 A A 0 0 A CONTRACT DATE: BUILDING TYPE: PLAN VERSION: SITE NUMBER: STORE NUMBER: 08.01.2018 N/A N/A N/A N/A TENANT FINISH GALL BLVD ZEPHYRHILLS, FL 33541 FINISH PLAN PHASE 2 FLOOR PLAN 100 PAINT SCHEDULE N/A I C NOT USED 1/4"=1'-Ul 1) PLOT DATE: MIKE MOYNAHAN (AL, AR, AZ, CA, CO, FL, GA, IA, KS, GIRTMAN & ASSOCIATES 615-350-6000 LA, MS, MN, MO, NE, NM, NV, OK, dgconstruction@bass-security.com OR, SC, SD, TN, TX, WI) COOK & BOARDMAN JOE HARRELL (CT, DE, IL, IN, KY, MA, MD, ME, MI, 336-837-0673 NC, NH, NJ, NY, OH, PA, RI, GROUP nationalsales@cookandboardman.com VA, VT, WV) INTERIOR DOORS, HOLLOW METAL FRAMES, and TOILET ROOM ACCESSORIES B2740 BOBRICK DOUBLE TOILET TISSUE DISPENSER B253 BOBRICK PAPER TOWEL DISPENSER 54-US32D BURNS PUSH PLATE 5410-32D-26D-GRIP BURNS PULL PLATE DDH-2250 ** DETEX DOUBLE DOOR HOLDER DS/1000MB DOOR SCOPE (FOR RECEIVING EXIT DOOR) 608Z 8" DOOR HOLDER 770SAV-3FT 3 FT DOOR SWEEP 770SAV4FT 4 FT DOOR SWEEP W101S-DANE-626 FALCON PASSAGE LEVERSET W581PD-DANE-626 FALCON STOREROOM LEVERSET A-2436 GAMCO 24" x 36" ANGLE FRAME MIRROR 150Sx36 GAMCO 1 1/2" X 36" GRAB BAR 150Sx42 GAMCO 1 1/2" X 42" GRAB BAR 150Sxl8 GAMCO 1 1/2" X 18" GRAB BAR MS-1 GAMCO MOP HOLDER 5400 HAGER DOOR CLOSER 7015SC8-26D * ILCO RIM CYLINDER 402-1/2B-26D IVES WALL STOP 4521326D4 IVES 4" DOOR HOLDER 8400-S32D-8X34 IVES KICK PLATE 425 HD - 6 FT. NATIONAL GUARD HD THRESHOLD (FOR RECEIVING EXIT DOOR) TA331OPC TACO DOOR VIEWER 2670-28 VON DUPRIN GUARD-X EXIT ALARM LOCK 2609 ** VON DUPRIN GUARD-X DOUBLE DOOR STRIKE 892SAV-841NCH WEATHERSTRIPPING * MUST HAVE ONE RIM PER EXIT DEVICE. ** MUST HAVE DOUBLE DOOR STRIKE AND TWO DOUBLE DOOR HOLDERS FOR ALL DOUBLE EXIT DOORS. NO. DOOR DOOR HARDWARE REMARKS TYPE WIDTH HEIGHT THICK. (1) FALCON PASSAGE LEVERSET #W101S-DANE-626 - NO KEY REO'D., (1) HAGER DOOR CLOSER SOLID WOOD DOOR OR HOLLOW CORE METAL 2O A 3'-0' 7'-0" 1-3/4" #5400, (1) IVES WALL STOP #402-1/2B-26D DOOR PAINTED SW #6991 "BLACK MAGIC' SEMI -GLOSS. (1) FALCON STOREROOM LEVERSET #W581 PD-DANE-626 - KEY #1, (1) HAGER DOOR CLOSER #5400, SOLID WOOD DOOR OR HOLLOW CORE METAL 1O B 3'-0' 7-0" 1-3/4" (1) IVES WALL STOP #402-1 /2B-26D, (1) TACO DOOR VIEWER #TA3310PC DOOR PAINTED SW #6991 'BLACK MAGIC" SEMI -GLOSS. (2) BURNS PULL PLATES #5410-32D-26D-GRIP, (2) BURNS PUSH PLATES #54-US32D, (4) IVES KICK SOLID WOOD DOOR OR HOLLOW CORE METAL OC 6'-0" 8'-0" 1-3/4 PLATES #8400-S32D-8X34, (2) HAGER DOOR CLOSERS #5400, (2) IVES 4' DOOR HOLDERS DOOR PAINTED SW #6991 "BLACK MAGIC" #452B26D-4 IF NOT FIRE RATED WALL. SEMI -GLOSS. (1) FALCON STOREROOM LEVERSET #W581 PD-DANE-626 - KEY #2, (1) HAGER DOOR CLOSER #5400, SOLID WOOD DOOR OR HOLLOW CORE METAL A 3-0" T-0" 1-3/4" (1) IVES WALL STOP #402-1/2B-26D, (1) RESTROOM DOOR SIGNAGE (PER DETAIL ON SHEET A5) DOOR PAINTED SW #6991 "BLACK MAGIC" SEMI -GLOSS. (1) FALCON STOREROOM LEVERSET #W581 PD-DANE-626 - KEY #2, (1) HAGER DOOR CLOSER #5400, SOLID WOOD DOOR OR HOLLOW CORE METAL OA 3-0' T-0 1-3/4' (1) IVES WALL STOP #402-1/2B-26D, (1) RESTROOM DOOR SIGNAGE (PER DETAIL ON SHEET A5) DOOR PAINTED SW #6991 "BLACK MAGIC SEMI -GLOSS. (1) FALCON STOREROOM LEVERSET #W581 PD-DANE-626 - KEY #2, (1) HAGER DOOR CLOSER #5400, SOLID WOOD DOOR OR HOLLOW CORE METAL OA 3'-0" T-0" 1-3/4" (1) IVES WALL STOP #402-1/2B-26D, (1) RESTROOM DOOR SIGNAGE (PER DETAIL ON SHEET A5) DOOR PAINTED SW #6991 "BLACK MAGIC SEMI -GLOSS. (1) BURNS PULL PLATES #5410-32D-26D-GRIP, (1) BURNS PUSH PLATES #54-US32D, (4) IVES KICK SOLID WOOD DOOR OR HOLLOW CORE METAL O A 3'-O" T-OP 1-3/4' PLATES #8400-S32D-8X34, (2) HAGER DOOR CLOSERS #5400, (1) IVES 4" DOOR HOLDERS DOOR PAINTED SW #6991 'BLACK MAGIC #452B26D-4 IF NOT FIRE RATED WALL SEMI -GLOSS. (1) VON DUPRIN GUARD-X EXIT ALARM LOCK #2670-28, (1) HAGER DOOR CLOSER #5400, (1) BURNS SOLID WOOD DOOR OR HOLLOW CORE METAL O3 D 3'-0' 7'-0' 1-3/4" PULL PLATE #5410-32D-26D-GRIP, (1) BURNS PUSH PLATE #54-US32D,(1) DOOR SWEEP, DOOR PAINTED SW #6991 "BLACK MAGIC WEATHERSTRIPPING, 1 NATIONAL GUARD HD THRESHOLD #425 HD-3 FT. SEMI -GLOSS. OPULL D 3' -O' 7'-0" 1-3/4 (1) VON DUPRIN GUARD-X EXIT ALARM LOCK #2670-28, (1) HAGER DOOR CLOSER #5400, (1) BURNS PLATE #5410-32D-26D-GRIP, (1) BURNS PUSH PLATE #54-US32D,(1) DOOR SWEEP, SOLID WOOD DOOR OR HOLLOW CORE METAL DOOR PAINTED SW #6991 'BLACK MAGIC WEATHERSTRIPPING, 1 NATIONAL GUARD HD THRESHOLD #425 HD-3 FT. SEMI -GLOSS. DOOR HARDWARE SCHEDULE N/A NO. ROOM FLOOR BASE A - WALL B - WALL C - WALL D - WALL CEILING REMARKS MAT. FINISH MAT. FINISH MAT. FINISH MAT. FINISH MAT. FINISH MAT. FINISH MAT. FINISH 1/8' ARMSTRONG VINYL ARMSTRONG #51858 4" RUBBER/ NEW GYP, SHERWIN WILLIAMS PAINT PURE NEW GYP. SHERWIN WILLIAMS PAINT PURE NEW GYP. SHERWIN WILLIAMS PAINT PURE NEW GYP. SHERWIN WILLIAMS PAINT PURE OPEN TO ABOVE WHITE FINISH DEMISING WALLS TO ROOF BREAK COMPOSITION TILE WITH VINYL BASE BLACK BOARD WHITE, PRO -MAR LATEX BOARD WHITE, PRO -MAR LATEX BOARD WHITE, PRO -MAR LATEX BOARD WHITE, PRO -MAR LATEX DECK. FINISH WALLS ALONG'A & 100 ROOM S-515 CLEAR ADHESIVE SEMI -GLOSS #SW7005 SEMI -GLOSS #SW7005 SEMI -GLOSS #SW7005 SEMI -GLOSS #SW7005 "B" 10'-O" A.F.F. FOR OPEN CLG. 1/8" ARMSTRONG VINYL ARMSTRONG #51858 4' RUBBER/ NEW GYP. SHERWIN WILLIAMS PAINT PURE NEW GYP. SHERWIN WILLIAMS PAINT PURE NEW GYP. SHERWIN WILLIAMS PAINT PURE NEW GYP. SHERWIN WILLIAMS PAINT PURE OPEN TO ABOVE WHITE FINISH DEMISING WALLS TO ROOF COMPOSITION TILE WITH VINYL BASE BLACK BOARD WHITE, PRO -MAR LATEX BOARD WHITE, PRO -MAR LATEX BOARD WHITE, PRO -MAR LATEX BOARD WHITE, PRO -MAR LATEX DECK. FINISH WALLS ALONG "A & 101 OFFICE S-515 CLEAR ADHESIVE SEMI -GLOSS #SW7005 SEMI -GLOSS #SW7005 SEMI -GLOSS #SW7005 SEMI -GLOSS #SW7005 "B" 10'-0" A.F.F. FOR OPEN CLG. 1/T ARMSTRONG VINYL ARMSTRONG #51858 4" RUBBER/ EXISTING SHERWIN WILLIAMS PAINT EXISTING & SHERWIN WILLIAMS PAINT NEW GYP. SHERWIN WILLIAMS PAINT EXISTING & SHERWIN WILLIAMS PAINT EXPOSED WHITE FINISH DEMISING WALLS TO SALES COMPOSITION TILE WITH VINYL BASE BLACK GYP. DAISY YELLOW, PRO -MAR NEW GYP. PRO -MAR LATEX SEMI -GLOSS, BOARD PRO -MAR LATEX SEMI -GLOSS, NEW GYP. DAISY YELLOW, PRO -MAR ROOF DECK 102 AREA S-515 CLEAR ADHESIVE BOARD LATEX SEMI -GLOSS #SW6910 BOARD BLACK MAGIC #SW6991, WALL BLACK MAGIC #SW6991, WALL BOARD LATEX SEMI -GLOSS #SW6910 BEHIND REGISTERS AND CART BEHIND REGISTERS AND CART CORRAL WALL, DAISY YELLOW CORRAL WALL, DAISY YELLOW #SW6910 REMAINING WALLS. #SW6910 REMAINING WALLS. CONCRETE FLOOR SONNEBORNE NOT SPECIFIED NOT SPECIFIED EXISTING & SHERWIN WILLIAMS PAINT PURE EXISTING & SHERWIN WILLIAMS PAINT PURE EXISTING SHERWIN WILLIAMS PAINT PURE EXISTING SHERWIN WILLIAMS PAINT PURE EXPOSED EXPOSED FINISH ALL WALLS TO ROOF DECK. RECEIVING KURE 1315 SEALANT NEW GYP WHITE, PRO -MAR LATEX NEW GYP. WHITE, PRO -MAR LATEX GYP. WHITE, PRO -MAR LATEX GYP. WHITE, PRO -MAR LATEX INSTALL 1/8' BLACK BULLNOSE 103 AREA BOARD SEMI -GLOSS #SW7005 BOARD SEMI -GLOSS #SW7005 BOARD SEMI -GLOSS #SW7005 BOARD SEMI -GLOSS #SW7005 STRIP AT ALL V.C.T. TO CONC. FLOOR TRANSITIONS. 1/8' ARMSTRONG VINYL ARMSTRONG #51858 4' RUBBER/ EXIST GYP. SHERWIN WILLIAMS PAINT PURE EXIST GYP. SHERWIN WILLIAMS PAINT PURE EXIST GYP. SHERWIN WILLIAMS PAINT PURE EXIST GYP. SHERWIN WILLIAMS PAINT PURE GYP. BD. OR WHITE FINISH WALLS TO ROOF DECK. MEN'S COMPOSITION TILE WITH VINYL BASE BLACK BOARD & C.T. WHITE, PRO -MAR LATEX BOARD & C.T. WHITE, PRO -MAR LATEX BOARD & C.T. WHITE, PRO -MAR LATEX BOARD & C.T. WHITE, PRO -MAR LATEX 2'x4' ACOUSTICAL FINISH DRYWALL TO 1 O' A.F.F. 104 R.R. S-515 CLEAR ADHESIVE SEMI -GLOSS #SW7005 SEMI -GLOSS #SW7005 SEMI -GLOSS #SW7005 SEMI -GLOSS #SW7005 CEILING CLG. HT. 8'-0" 1/8' ARMSTRONG VINYL ARMSTRONG #51858 4 RUBBER/ EXIST GYP. SHERWIN WILLIAMS PAINT PURE EXIST GYP. SHERWIN WILLIAMS PAINT PURE EXIST GYP. SHERWIN WILLIAMS PAINT PURE EXIST GYP. SHERWIN WILLIAMS PAINT PURE GYP. BD. OR WHITE FINISH WALLS TO ROOF DECK. WOMEN'S COMPOSITION TILE WITH VINYL BASE BLACK BOARD & C.T. WHITE, PRO -MAR LATEX BOARD & C.T. WHITE, PRO -MAR LATEX BOARD & C.T. WHITE, PRO -MAR LATEX BOARD & C.T. WHITE, PRO -MAR LATEX 2'x4 ACOUSTICAL FINISH DRYWALL TO 1 O' A.F.F. 105 R.R. S-515 CLEAR ADHESIVE SEMI -GLOSS #SW7005 SEMI -GLOSS #SW7005 SEMI -GLOSS #SW7005 SEMI -GLOSS #SW7005 CEILING CLG. HT. 8'47 1/8' ARMSTRONG VINYL ARMSTRONG #51,858 4" RUBBER/ EXIST GYP. SHERWIN WILLIAMS PAINT PURE EXIST GYP. SHERWIN WILLIAMS PAINT PURE EXIST GYP. SHERWIN WILLIAMS PAINT PURE EXIST GYP. SHERWIN WILLIAMS PAINT PURE GYP. BD. OR WHITE FINISH WALLS TO ROOF DECK. UNISEX COMPOSITION TILE WITH VINYL BASE BLACK BOARD & C.T. WHITE, PRO -MAR LATEX BOARD & C.T. WHITE, PRO -MAR LATEX BOARD & C.T. WHITE, PRO -MAR LATEX BOARD & C.T. WHITE, PRO -MAR LATEX 2'x4' ACOUSTICAL FINISH DRYWALL TO 1 O' A.F.F. 106 R.R. S-515 CLEA�i ADHESIVE SEMI -GLOSS #SW7005 SEMI -GLOSS #SW7005 SEMI -GLOSS #SW7005 SEMI -GLOSS #SW7005 CEILING CLG. HT. 8'-0' 11T ARMSTRONG VINYL ARMSTRONG #51858 4' RUBBER/ EXISTING & SHERWIN WILLIAMS PAINT, EXISTING & SHERWIN WILLIAMS PAINT, EXISTING & SHERWIN WILLIAMS PAINT, EXISTING & SHERWIN WILLIAMS PAINT, 2' X 4' WHITE FINISH WALLS TO ROOF DECK. HALL COMPOSITION TILE WITH VINYL BASE BLACK NEW GYP. PRO -MAR LATEX SEMI -GLOSS NEW GYP. �SS PRO -MAR LATEX SEMI-GLAB NEW GYP. PRO -MAR LATEX SEMI -GLOSS NEW GYP. PRO -MAR LATEX SEMI -GLOSS ACOUSTICAL FINISH DRYWALL TO 1 O' A.F.F. 107 S-515 CLEAR ADHESIVE BOARD #SW7005 PURE WHITE ABOVE BOARD #SW7005 PURE WHITE VE BOARD #SW7005 PURE WHITE ABOVE BOARD #SW7005 PURE WHITE ABOVE CEILING #SW6991 BLACK MAGIC #SW6991 BLACK MAGIC #SW6991 BLACK MAGIC #SW6991 BLACK MAGIC CLG. HT. 8'-0" WAINSCOT @ 3'-0 A.F.F. WAINSCOT @ 34PA.F.F. WAINSCOT @ 3-0"A.F,F. WAINSCOT @ 3'-O'A.F.F. CONCRETE FLOOR SONNEBORNE NOT SPECIFIED NOT SPECIFIED NEW GYP. SHERWIN WILLIAMS PAINT PURE EXISTING & SHERWIN WILLIAMS PAINT PURE EXISTING & SHERWIN WILLIAMS PAINT PURE EXISTING & SHERWIN WILLIAMS PAINT PURE EXPOSED EXPOSED FINISH ALL WALLS TO ROOF DECK. 108 LOCKED KURE 1315 SEALANT BOARD WHITE, PRO -MAR LATEX NEW GYP. WHITE, PRO -MAR LATEX NEW GYP. WHITE, PRO -MAR LATEX NEW GYP. WHITE, PRO -MAR LATEX INSTALL 11T BLACK BULLNOSE STORAGE SEMI -GLOSS #SW7005 BOARD SEMI -GLOSS #SW7005 BOARD SEMI -GLOSS #SW7005 BOARD SEMI -GLOSS #SW7005 STRIP AT ALL V.C.T. TO CONC. FLOOR TRANSITIONS. V �w o Qom C'M US c) Lo N C/)(.000 Lo W w -- [--I z Q w�l- �x0rr VQzU`Y' 0 N 0 N ILL F� O Q O z w U) z w U J Q lr O J U_ w Y rn z Q am w w 16009 0 0 0 a 0 0 0 CONTRACT DATE: BUILDING TYPE: PLAN VERSION: SITE NUMBER: STORE NUMBER: 08.01.2018 N/A N/A N/A N/A TENANT FINISH GALL BLVD ZEPHYRHILLS, FL 33541 FINISH PLAN PHASE 2 SCHEDULES 2mO FINISH SCHEDULE N/A PLOT DATE: Iu.11_y� LOW VOLTAGE VENDOR TO F AND INSTALL 24 GA., 4 TWISI CATEGORY -FIVE (CATS) DAT/ WITH MODULAR COMBO RJ- JACK AT MANAGER'S OFFICE BE RUN FROM JACK TO DAT) LOCATION WITH & LEFT COIL CEILING FOR INSTALLATION HUB. AN RJ-45 MALE FITTING BE CRIMPED ON THIS END. E GENERAL STORE OPENING T MAKE FINAL CONNECTION 11\ DATA HUB. DEDICATED RECEPTACLE SECURITY OUTLET AT 7'-0" INTERFACE ALARM PANEL INTERFACE EQUIPMENT DATA PATCH PANEL DED. QUAD RECPT. @ 6'-0" FOR VSAT, D-LINK EQUIP. HEAVY DUTY, 12" X 20" SHELF (BY GC) FOR VSAT & DATA HUB EQUIPMENT. - DED. DUPLEX RECPT. @ 41-011 FOR I NTERFACE. Y2" THICK (MIN.) PLYWOOD, 60" WIDE x 48" HIGH, PAINTED TO MATCH WALL AT 36" AFF. WALL "A" NOT TO SCALE WALL "C" NOT TO SCALE # P3AC24-16-8 L, 16 CAMERA, 24 VAC, 8 AMP, POWER SUPPLY CABINET. #BW-106 VIDEO CONVERTER ENCLOSURE. DEDICATED QUAD RECPT. @ 36" FOR CCTV EQUIP. DVR & MONITOR FOR CCTV. DEDICATED QUAD RECPT. @ 36" QCCCQ Tn nATA WALL "B" NOT TO SCALE WALL "D" 1"CONDUIT TO SALES FLOOR QUADRANTS 1"CONDUIT TO VOIC -/DATA BOX 1"CONDUIT TO REGISTERS 1-1/4" CONDUIT TO SATELLITE 2" CONDUIT TO RECEIVING DATA PATCH PANEL HEAVY DUTY, 12" X 20" SHELF (BY GC) FOR VSAT & DATA HUB EQUIPMENT. Y2" THICK (MIN.) PLYWOOD, 30" WIDE x 48 HIGH, PAINTED TO MATCH WALL AT 36" AFF. CONTRACTOR SHALL LEAVE AN AS -BUILT SET OF CONSTRUCTION PLANS INSIDE THE OFFICE. THEY SHALL BE ROLLED UP AND PLACED INSIDE A 4" X 36" PVC PIPE AND MOUNTED HORIZONTALLY ON THE WALL ABOVE THE DOOR. PC MOBILE CART NC)TF- GC PROVIDES AND INSTALLS ALL OUTLETS, ALL CONDUIT, J BOX FOR DATANO I C E PORT, HEAVY DUTY SHELF AND PLYWOOD. ALL OTHER COMPONENTS AND EQUIPMENT PERTAINING TO OFFICE ARE PROVIDED BY DIG OR LOW VOLTAGE VENDOR. OFFICE 101 NOT TO SCALE NOT TO SCALE U c ODLO a N��� co �VwwcnU? a� ,.., LIJ F--UJzUco J �u- a 0 rr Q 0 z w z w v Q 0 a^ 0 J U_ w Y Z Q w w J 16009 a 0 0 0 0 0 0 0 CONTRACT DATE: BUILDING TYPE: PLAN VERSION: SITE NUMBER: STORE NUMBER: 08.01.2018 N/A N/A N/A N/A TENANT FINISH GALL BLVD ZEPHYRHILLS, FL 33541 FINISH PLAN PHASE 2 OFFICE INTERIOR ELEVATIONS OFFICE PLAN � ELEVATIONS NOT TO SCALE 3mO PLOT DATE: I __LLL� I" "L-1, I iiLLl_ LU__! IT n jlprlpLl_ I.:. I I MIRROR MTD @ 40"A.F.F. MAX TO BOTTOM OF REFLECTING SURFACE LAV. VERTICAL S.S. GRAB INSULATE HOT WATER & DRAIN J BAR (IF RQ'D) PIPES DRYER NOTES.- 48'S.S. GRAB BAR PAPER TOWEL DISPENSER rr -q- T.S. COVER DISPENSER SHALL (D 1 . TOP OF GRIPPING SURFACE PULL STATION 14"M IN. / 17" MAX. 0' MAX 0-25' MA 33TO36MAXTOTHETOPOF BE MOUNTED 1 1/L- (MIN.) [3 to 41" BELOW GRAB RAIL PROJECTION FROM co THE BAR. SEE NOTES BELOW C:) WALL URINAL 2. 12'MINIMUM CLEAR U3 0 Lr) ABOVE GRAB BAR 6'TO 120'MAX (00 a c) C\j cy) 2!-0' Lu 36S.S. GRAB BAR-------,, 5 I' lir U- 0 Lj= LL U) 00 < < < < Ir — cl 12 - - Lo 33' (EXCEPT (—a k 0 < < Lj < Lu LJJ tj J < < < TANK TOILETS, Ir z < 0-i x ui 0 x 0 o WHICH SHALL BE 2 [-- < a- < 'IT 4) U) x 0 a- cr) CD LLI < 30) 0) C\lGel co o Eo ::> Lu co 1--o 0,;Y CD 'IT q- "I- C) 0 < 1 -19" 19'TO 48A.F.F. FOR OPERABLE < 6' MAX. DEPTH x 30' MIN. WIDTH TOE c\j 3: OPENING W/O OBSTRUCTION CLEARANCE C\j FROM GRAB BAR SWITCHES ;:3- 8" MIN. DEPTH x 30" MIN. THERMOSTAT 0 c\j CONTROLS MOUNTED ON WIDTH KNEE SPACE FIRE ALARM LL WIDE SIDE OF TOILET AREA 0' MAX. 30r 24' MAX.Q it 3Cr MOUNTING HTS. & CLEARANCES FOR ACCESSIBILITY BY THE DISABLED N.T.S. J co 6-0- MIN. (1525) -4 Lo 3-0- MIN. (965) PROTRUDING OBJECT I I _ I _ _ 6" MAX. (150) co z F_ %D FREESTANDING OBJECT Lu 0 < c\j . 41 EXAMPLE: DRINK MACHINE, ETC. MOUNTED ON POSTS OR PYLON MAY OVERHANG 1 Z Lu 0 MAX FROM 2TTO 8(Y' ti o V_ 17" MIN. TO < 0 ABOVE FINISH FLOOR 12' 18" MAX co T:� 4" c) Lo z c1li 1 OBJECT PROJECTION FROM z CLEAR 0 0') > 10-24" MAX i 1 MAX WALL BETWEEN 27"TO 8(r —0- 2 Ir FLOOR < 0 2 y ABOVE FINISH FLOOR SHALL SPACE C? _j . J" CD TOILET PAPER b PROTRUDE NO MORE THAN co op 'T LL f,�, L;�,` I = N — z 36M IN. CLR. CD B 4� 4v MAX. VERTICAL GRAB co co BAR. SEE DTL 1 ACCESSIBLE ROUTE (100) Lu < iD2, OBJECT PROJECTION 00o CoCD FROM WALL LESS THAN 48"MIN. 2'-8"MIN. 0 TL T_ 27"ABOVE FINISH FLOOR\\�\ 13 11Z 0I o LL 40 < Z 1_0 MAY PROTRUDE ANY MAX (815) ]- 0 Z 7470 0 T D Lu AMOUNT 0 <u T c\j IF TOILET STALL 2� 0 0 cl) Is -ZEE < z CONDIMENTS FLOOR SHALL BE V CONSTRUCTED OF SOLID WALLS < :E LL 0 c� < a_ zo SLIP -RESISTANT SURFACE WITHOUT 9" OF TOE CLEARANCE Lug < . a_ lk :E ;;�- &.3 a- cd AND LEVEL WITH MAX 1/4� UNDER PARTITION, PROVIDE < CHANGE IN LEVEL ADDITIONAL 6'WIDTH AND DEPTH 0 u 'T NOT USED N.T.S. REACH RANGES N.T.S. _Fl 4] INT. ACCESS. ROUTE CLEARANCES 112, 1, ACCESSIBLE URINAL 3/4"=v-cP 6j STANDARD TOILET STALL N.T.S. 2 811 16009 MAX. MAX. REQ'D IN REQ'D IN < CAONLYCA ONLY SIGN POST OBSTRUCTION z A 0 GRAB BAR SHALL BE 1-114° TO 2MAX., TYPICAL OUTSIDE DIA. 0 -5 C? _j 0 �o U LL _j 2 CLEAR U- < MIN.' FLOOR U) 0 w j Z MAX fr CLR. 0 Lu SPACE LL LL co co 0 71 1# <Lu, J* MIN. m ) z ol o < 0 < 2- 1/4°x3EXPANSION ANCHORS AT t, 0 cp MASONRY OR CONC. WALL 2- #1 Ox2' Lu ca �-- uj SCREWS AT WOOD OR STEEL STUD .-j X 1-- 2 j= 0 < (D WALL-TYP. c\l LLJ 48' MIN. 4. (D e- T, OD 1/8)c2* BENT PLATE WELDED TO RAIL 2� AND1/8'x3" DIAMETER MOUNTING ACCESSIBLE ROUTE WALK ----- PLATE 9 4'-(f CONTRACT DATE: 08.01.2018 2"x6' BLOCKING AT WOOD STUD WALLS (OMIT BLOCKING AT MASONRY OR BUILDING TYPE: N/A CONC. WALL) - TYPICAL PLAN VERSION: N/A SITE NUMBER: N/A ACCESSIBLE RESTROOM DOORS N.T.S. 115 PROTRUDING HAZARDS 1/2' l'- GRAB BAR 3, - 1,-o, 7 ACCESSIBLE LAVATORY 3/4' l'-CY' $ STORE NUMBER: N/A TENANT FINISH 19, 3(f e- CLEAR 1. INDICATED DIMENSIONS, HEIGHTS, DEPTHS, AREAS AND OTHER GRAPHIC INFORMATION ARE PROVIDED AS MINIMUMS THAT MUST BE MAINTAINED. GALL BLVD Lu MOUNT COAT HOOK ON ZEPHYRHILLS, FL 33541 INSIDE OF TOILET STALL REINFORCED S.S. 0 THE DETAILS SHOWN ARE CONCEPTUAL ONLY AND INTENDED TO SHOW 3, a: DOOR LATCH WITH THROUGH Dl!: ABSOLUTE MINIMUMS AND SHALL BE COORDINATED WITH THE OTHER BOLTED KEEPER. ADA CONSTRUCTION DOCUMENTS ASSOCIATED WITH THIS PROJECT. C) w COMPLIANT cl) _j OfO Fj) 0 C/) ui 2. 6(Y TURNING SPACE O ol 0 - PERMIT -FED OVERLAP LIMITED TO 1 ARM OF T-SHAPED SPACE < - CAN OVERLAP FIXTURE & DOOR CLEARANCE < - DOOR CAN SWING INTO TURNING SPACE A MAXIMUM OF 12' S.S. PULL (BOTH SIDES) ON ALL ACCESSIBLE LL 3. RESTROOM, IN GENERAL, DOOR SWING MUST BE OUTSIDE OF THE FXTR CLEAR FINISH PLAN > TOILET STALLS, MOUNT ACCESSIBLE ROUTE FLOOR SPACE HOWEVER A DOOR CAN SWING INTO FIXTURE CLEAR FLOOR PHASE 2 PULLS BELOW LATCH 48' SPACE IF WHEELCHAIR SPACE 30'X49'IS PROVIDED BEYOND THE DOOR SWING. AND KEEPER. co LL 19, 30p CLEAR 4. TOILET ROOM MUST ALLOW FOR SIDE TRANSFER - 4Z BETWEEN FIXTURES BOBRICK OR CHRISTY LL: CLEAR < COMMERCIAL Al., bo HARDWARE & SUPPLY It 2 -13 D NOTE: DOOR HOOKS WAREHOUSE ACCESSIBILITY SHALL BE PLACED IN z #039-6529 OR SIMILAR ACCESSIBLE STALLS CD UJ ADA COMPLIANT HOOK. REQUIREMENTS BETWEEN 4(f MIN TO LL CHRISTYHARDWARE.COM 48" MAX ABOVE FINISH LL: 877 FLOOR -544-5400 L BE v S PIPESU E L ATE Ho jq4. M IN 1 Tl ROJECTION WALL URINAL r Ll>1 E_ - 77" cl 1 _*2;, cy) NOTE: 1. MAINTAIN 36' MIN. CLEAR AISLE EGRESS PATHS TO EXIT DOORS. NOTE: SEE DOOR SCHEDULE. AND DOOR SCHEDULE NOTES NOTE: SEE DOOR SCHEDULE. AND DOOR SCHEDULE NOTES 2. INTERNATIONAL SYMBOL OF ACCESSIBILITY REQUIRED ON TOP EDGE OR FRONT OF ALL ACCESSIBLE TABLES. PLOT DATE: COAT HOOK N.T.S. 20 PARTITION IDOOR LATCH @ PULL 16 CHANGES IN LEVEL N.T.S. 1121 DINING ROOM SEATING CLEARANCES N.T.S7.8 GENERAL NOTES 4 I U G� Zw"Zj- lumA A Npo r-- CO C/� 00 UwwU) wv��rn �WLZ �Q� CixUpC=cTo U < Z — N I ON LL a Enginaaring Professionals, Mc. 2 E E Mechanical Engineers EB-0006437 O 1717 N. Howard Avenue Tampa, FL 33607 (813) 251-6848 12"0 CONNECT TO E) XHA ST 6 CD BCD 6B LOUVER. IN A S NCE OF 3 CFM 100 ffm 10 FM o 0 0 o a o 0 0 0 (E)LOUVER `O, 12X12 LOUVE RUSKIN EVH— , APPROVED EQUAL 6" CD 50 CFM F-�---- -- E 00 Ik_y I O O O 0 O O Ir-a I �II I I_J I I 12"0 L---- J 30X20 SA & 30X20 RETURN DUCT DOWN 18X18 GC (E)RTU-1 ON ROOF TO BE FROM RTU ON ROOF ABOVE TO CONCENTRIC `II (TYP OF 2) ABANDONED IN PLACE. OPTION TO DIFFUSER. RTU TO REPLACE EXISTING AT SAME REMOVE AND PATCH ROOF AS LOCATION. FIELD VERIFY EXACT LOCATION OF ` NEEDED. UNIT. COORDINATE WITH ARCHITECT AND $`� G ESN'°'•Cj' °se 14x8 SRC BAN LORD PRIOR TO INS PATCH ROOF ALA. 150 CFM OPENINGS AS REQ IRED. ALL ROOF WORK TO ° 3° 75�4.2F�"t T RTU-2 ° BE PERFORMED BY' LANDLORD APPROVED ° ° A = m R p ROOFING CONTRACTOR. S T of 12"0 tE � ��•••; ���® o o a a a ®®®S •< °�•F��, ®®w 1 i ®S • O R �. E'�� r--- ---- --- r-- - ---®It ONAI- �,,, I � I I SHANE R. HAMILTON P.E. IL I_Tyi I M I QFL ORIDA LICENSE #75420 ❑ R S T OUTE NEW CONDENSATE DR S r DRAIN TO EXISTING RMINAON.ILMJI IL_JI I L_J CAL I, I I I I I I I I I LMJ I I I I I I I Q '. ❑ i I i 0 i O O I O 0 I I RTU-3 ON L SIDE DISCHARGE CONCENTRIC AIR -(E)RTU-4 ON ROOF TO BE L--- --- ' RTU-5 ON ONCENTRIC RETURN-20x1 SA & 0x16 RE RN `------- ABANDONED IN PLACE. ROOF ABOVE DU OWN FROM RTU-2 ROOF ABOVE ( 650 CFM) R OF AB TO DIFFUSER SYSTEM. CURBS PLUS, INC. OPTION TO REMOVE AND ❑ MODEL CDR (TYP. FOR ALL 3 UNITS) PATCH ROOF AS NEEDED. COWiNTRIC AFFUSER ALL EXPOSED DUCTWORK 0 BE 1O"o Q SPIRAL DOUBLE WALL INS ATED. INTED TO MATCH CEILING " O ° ° ° 80 CD 12X12 TGC 4SBM o Q (TYP OF 2) . . 0 O O O O 0 12x12 TGC JE (TYP OF 2) CONTRACT DATE: 08.01.2018 _8". CD tE 14 CDM BUILDING TYPE: N/A o a o a a o 0 0 0 PLAN VERSION: N/A SITE NUMBER: N/A COORDINATE FINAL PLACEMENT OF T—STAY ON SITE (TYP FOR ALL) 0"o STORE NUMBER: N/A F 8"0 W RTU-3 T E E O RTU-5 I riqo 10X6 SRC TENANT FINISH 100 CFM 10x10 TGC 0 0 0 0 GALL BLVD TYP OF 2 ZEPHYRHILLS, FL 33541 FINISH PLAN PHASE 2 q FLOOR PLAN - MECHANICAL FLOOR PLAN SCALE: 1/8"=1'-0" 8200.00 MECHANICAL m 1 PLOT DATE: 9/07/2018 MINIMUM CODE REQUIRED OUTSIDE AIR VENTILATION RATES PER A 62R1 E20STOANDARD AzR EZ zRDzRD =Voz NET AREA CODE REQ D NUMBER PEOPLE CODE REQ D OA CODE REQ D OA ZONE AIR DISTRIBUTION TOTAL OA DEFAULT OCCUPANT AREA OUTDOOR AIR RATE BASED ON PEOPLE OUTDOOR AIR RATE BASED ON TOTAL EFFECTIVENESS REQUIRED BY DENSITY FLOOR PEOPLE VBz CODE OD AREA Az Ra Pz Rp AzRa+PzRp Ez Voz AREA -SERVED CATEGO YY P/1000 SF SF CFM/S.F. CFM PERSON(S) CFM/PERS CFM CFM CFM RETAIL SALES 15 10000 0.12 1200 + 80 7.5 375 1575 / 0.8 = 1968 RECEIVING STORAGE - 1700 0.12 192 + - - - 192 0.8 = 218 TOTAL REQUIRED = 2186 TOTAL PROVIDED = 2200 IMPORTANT NOTES FOR CONTRACTOR AND SUBCONTRACTOR: ANY DISCREPANCIES OR OMISSIONS ON THESE DOCUMENTS MUST BE BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR TO THE COMMENCEMENT OF CONSTRUCTION AND BID TO OWNER. FAILURE BY CONTRACTOR TO IDENTIFY DISCREPANCIES OR OMISSIONS WILL THEN BECOME THE RESPONSIBILITY OF THE CONTRACTOR. TENANT'S CONTRACTOR IS RESPONSIBLE FOR COMPLIANCE WITH ALL REQUIREMENTS WITHIN THE LANDLORD'S TENANT CRITERIA MANUAL, RULES AND REGULATIONS. MECHANICAL NOTE: COORDINATE EXACT LOCATION OF RTUS WITH STRUCTURAL AND ARCHITECT DWGS. SUPPLY AND RETURN DUCT MUST RUN THROUGH OPEN WEBBING OF ROOF TRUSSES. COORDINATE LOCATION OF DUCTWORK WITH ROOF TRUSSES INSTALLED (TYPICAL). REQUIRED 10'-0" MINIMUM SEPARATION BETWEEN EXHAUST AND, AIR -INTAKES. ALSO KEEP IN CONSIDERATION ADJACENT TENANT EQUIPMENT. FAN SCHEDULE TAG - EF-1 EF-2 & 3 SERVICE - EXHAUST EXHAUST AIR QUANTITY CFM 75 280 EXT. STATIC PRESS. IN. H2O 0.225 0.225 FAN TYPE - CEILING CEILING DRIVE - DIRECT DIRECT SONES - 1.0 4.0 MOTOR CFM/WATTS 30.2 WATTS 99.4 WATTS FAN SPEED RPM 900 1500 POWER V/0 115V/1 of 115V/10 CONTROL - W/LIGHT SWITCH W/LIGHT SWITCH LOCATION - CEILING CEILING MANUFACTURER - COOK COOK MODEL - GC-146 GC-422 NOTES ® 01 1 01 VIBRATION ISOLATORS, BACKDRAFT DAMPER, HANGING KIT, FAN SPEED CONTROLLER, PLUG DISCONNECT. RTU-1 THRU 5: UNIT SHALL BE CONTROLLED BY ITS ELECTRONIC 7-DAY PROGRAMMABLE T-STAT. UNIT SUPPLY FAN SHALL RUN CONTINUOUSLY IN THE OCCUPIED MODE, CYCLE WITH HEATING AND COOLING WHILE UNOCCUPIED. UPON A RISE IN SPACE TEMPERATURE, UNIT COMPRESSOR AND CONDENSER FANS SHALL ACTIVATE IN STAGE TO SATISFY SPACE. UPON A DROP IN SPACE TEMPERATURE, ELECTRIC HEAT SHALL BE ACTIVATED IN STAGE TO SATISFY SPACE TEMPERATURE. OCCUPANCY SCHEDULE SHALL BE SET OCCUPIED/UNOCCUPIED BASED ON TENANT SPECIFIC REQUIREMENTS. THERMOSTAT SHALL BE SET FOR OCCUPIED COOLING 75 , OCCUPIED HEATING 70 ; UNOCCUPIED COOLING 80 ; UNOCCUPIED HEATING 60'. ALL TIME AND TEMPERATURE SETPOINTS SHALL BE VERIFY BY LANDLORD AND TENANT PRIOR TO PROGRAMMING. THERMOSTAT SHALL BE PROGRAMMED BY MECHANICAL CONTRACTOR IN THE PRESENCE OF TENANT'S REPRESENTATIVE. MAX. 20' TRANSITION SECURE WITH TWO 1 #8 S/S SCREWS MIRO PIPE SUPPORTS RIGID POLYCARBONATE RESIN ROOFING AINUM STRAP CRADLE PROVIDE TREAD PIECE UNDER SUPPORT ROOF INSULATION METAL ROOF DECK ROOF PIPE SUPPORT DETAIL NO SCALE NOTES: 1) NO WOOD ALLOWED 2) SPACING FOR PVC PIPE - 5'-0- SPACING FOR STEEL PIPE = 10'-0- LEVEL E::3--HDENTIFICATION G WITH UNIT ROOF MOUNTED NUMBER AND A EA SERVED PACKAGE A/C UNIT 0.25 D (e MIN. PER SMACNA) RECTANGULAR DUCT N N VOLUME DAMPER TTING WITH LOCKING TYPE VOLUME DAMPER. ALL TAKEOFF EQUAL TO FLEXMASTER STO. DUCT OR ROUND SHEET METAL DUCT. FLEX MAX. 8'-0- LONG, USE CLAMP TO ATTACH DUCTS AND SEAL SUPPORT EVERY FOUR FEET FROM STRUCTURE BRANCH DUCT DETAILS NO SCALE U JOIST (TYP.) NOTE: INSULATE ALL COLLARS. SEAL TO PLENUM AND FLEX INSULATION DUCT RISER/LEVELING DETAIL NOT TO SCALE **I/4- LAG BOLTS THRU UNIT FRAME AND CURB. 6. ON CENTER. AVOID DRILLING COIL AREA. APPLIES TO ALL SIDES. MINIMUM 8- CLEARANCE REQUIRED BETWEEN BOTTOM OF EQUIPMENT AND TOP OF FINISHED ROOF. ADD SHIMS AS REQUIRED. FLASHING & COUNTER FLASHING. SEE ARCH. D P.T. W.D. NAILER ROOF INSULATION ROOF STRUCTURE FROM DUCT N TO DROP DIFFUSER EXIBLE CANVAS VECTION (TYP.) AIR DEVICE SCHEDULE MARK TYPE MATERIAL FINISH ACCESSORIES MANUFACTURER AND MODEL REMARKS CD CEILING DIFFUSER ALUMINUM BAK. WHT. ENAMEL OBD PRICE SCD RRC RETURN REGISTER ALUMINUM BAK. WHT. ENAMEL OBD PRICE 630FL ' TGC TRANSFER GRILLE ALUMINUM BAK. WHT. ENAMEL PRICE 630FL ' SRC SUPPLY REGISTER ALUMINUM BAK. WHT. ENAMEL OBD PRICE 620FS RTU UNIT SCHEDULE MARK - (N)RTU-2 N)RTU-3 & 5 SUPPLY AIR CFM 1,750 4,750 OUTSIDE AIR CFM 350 925 EXT. STATIC PRESSURE IN. H2O 0.5 0.8 FAN SPEED RPM 1350 1096 MOTOR HP 1 3.8 POWER VOLTS/PH. 208V/30 208V/30 MCA AMPS 45 100 MOCP AMPS 45 100 FILTER TYPE - 2"-30% 2"-30% TOTAL COOLING CAPACITY BTUH 58,300 142,000 SENSIBLE COOLING CAPACITY BTUH 52,784 131,438 ENT. AIR TEMP. 'F/E 79.4/66.7 79.1 /66.2 LVG. AIR TEMP E/'F 57/56.1 57.3/56.2 HEATING CAPACITY KW 15.0 30.0 EER BTU/WATT 14 SEER 11.0 AMBIENT TEMP. 'F 95 95 UNIT WEIGHT(TOTAL) LBS. 688 1224 MANUFACTURER - LENNOX LENNOX MODEL NO. - ZCB060S4B ZCA150S4M NOTES ® 01 ( 01 ELECTRIC COOLING/ CTR NG ,OFTOP UNIT WITH 18" ROOF CURB, SINGLE POINT POWER CONNECTION, PROVI OKE DETECTO IN SUPPLY AIR DUCT, WINTER START UP, W.P. DISCONNECT BY ELNS L DIVI AIL GUARD, RAIN HOOD, 7 DAY PROGRAMMABLE T-STAT WITH CLEAR LOCKABLE BOX, ECONOMIZER, ENTHALPY SENSOR, FIELD INSTALLED DRAIN PAN OVERFLOW SWITCH, CORROSION RESISTANT BIRD SCREENS. COORDINATE WITH TENANT PRIOR TO PURCHASING. DISCONNECT BY ELECTRICAL DIVISION. PROVIDE PLUG FOR MAINTENANCE CONDENSATE HORIZONTAL AIR SCOOP MAX. TONS PIPE SIZE 2 3/4" 5 1" ROUND SUPPLY AIR DUCT. CONNECT 30 1 1/4- BRANCH TO SUPPLY AIR DUCT DROP, 50 1 1/2" ABOVE CONCENTRIC DIFFUSER. tk VOLUME DAMPER UCT DROP (FLEXIBLE OT ALLOWED) NOTE: INSTALL HORIZONTAL AIR SCOOP HAVING A CONTINUOUSLY CURVED CROSS SECTION AND BALANCING DAMPER AT DUCT CONNECTION TO DIVERT SUPPLY AIR INTO THE CONNECTED DUCTWORK. LENGTH OF SCOOP SHALL BE LIMITED TO THE WIDTH OF THE SUPPLY AIR ANNULAR SPACE. TYPICAL SUPPLY BRANCH CONNECTION DETAIL EDGE OF ROOF TOP UNIT, ROOF CAP OR FAN. FAN MAIN FRAME -GASKET BETWEEN UNIT AND FULL PERIMETER OF CURB SEALANT AT ALL SCREW PENETRATIONS BY HVAC TREATED WOOD NAILER 18- FABRICATED, MIN 14GA. CURB BY HVAC INSTALLED BY GENERAL CONTRACTOR SHIM AS REQUIRED TO LEVEL UNIT. INSULATION SPACER BLOCK, BETWEEN — CURB de DECK IF REQUIRED FOR LEVELING --DUCT ROOF OPENING AS REQUIRED FOR DUCTWORK +•'1/rO BOLTS, NUTS, A AND SUPPORT FRAMING, SEE STRUCTURAL SHEETS FOR WASHERS ON 6- CENTERS. ADDITIONAL INFORMATION. APPLIES TO ALL SIDES "REINFORCING SHOWN IS FOR 170-MPH WAND LOAD DESIGN. ROOF CURB DETAIL NOT TO SCALE OUTSIDE AIR INTAKE INSULATED SUPPLY TRANSITION ROOF JOIST PROVIDE CLEANOUT AT EACH CHANGE OF DIRECTION OR EVERY 30' DRAIN LINE. SLOPE WITH FLOW A 1/8-/FT TO DRAIN OR OUTSIDE A NO SCALE ROOF TOP UNIT INSULATED PANELS (TYP.) I I 1 I I I I I I I I I I I I I I I I A = FAN PRESSURE + 1 INCH DRAW THRU APPLICA INSULATED RETURN TRANSITION —ROOF CURB DIFFUSER EVEN WITH BOTTOM OF TRUSS ALUMINUM CONCENTRIC DIFFUSER BY PLENUMS INCORPORATED RTU AND CONCENTRIC AIR DIFFUSER DETAIL NO SCALE NOTES: OSUPPLY/ RETURN TRANSITION PACKAGE AND ROOF CURB SHALL BE PROVIDED BY THE CONTRACTOR AND ASSEMBLED IN THE FIELD. FIELD FABRICATED TRANSITIONS WILL NOT BE ACCEPTED. 02 CURB AND CONCENTRIC DUCT KIT MUST BE INSTALLED PRIOR TO SETTING RTU IN PLACE. ALIGN RTU SUPPLY OPENING WITH TO MATCH SUPPLY OPENING IN CONCENTRIC DUCT. 03 FIELD BAFFLES MAY BE REQUIRED FOR BALANCING. 04 SUPPLY AND RETURN DUCT SHALL BE INTERNALLY LINED. RETURN DUCT SHALL BE MOUNTED WITHIN THE JOIST SPACE. MECHANICAL GENERAL NOTES: • IN GENERAL, PLANS AND DIAGRAMS ARE SCHEMATIC ONLY AND SHOULD NOT BE SCALED. • INTENT OF THESE NOTES AND MECHANICAL NOTES ON DRAWINGS IS TO CLARIFY THE SCOPE OF WORK AND ALERT CONTRACTOR OF EXISTING CONDITIONS. CONTRACTOR TO VISIT SITE AND VERIFY ALL CLEARANCES BEFORE FABRICATION OF DUCTWORK AND PROVIDE ADDITIONAL OFFSET AND/OR CHANGES IN DUCT SIZES TO MEET FIELD CONDITIONS AND COORDINATE WITH ELECTRICAL, PLUMBING AND FIRE PROTECTION SUBCONTRACTOR BEFORE ANY CONSTRUCTION WORK. • COORDINATE AIR DEVICE LOCATIONS WITH LIGHTING FIXTURES AND FIRE SPRINKLER HEADS. • DUCT DIMENSIONS SHOWN ON DRAWINGS ARE CLEAR INSIDE DIMENSIONS. • ALL SUPPLY AND RETURN DUCTWORK SHALL BE EXTERNALLY INSULATED SHEET METAL CONSTRUCTION IN ACCORDANCE WITH LATEST SMACNA STANDARDS. • ALL WALL MOUNTED THERMOSTATS AND/OR TEMPERATURE SENSORS SHALL BE INSTALLED AT AN ELEVATION OF 48" ABOVE FINISHED FLOOR TO THE TOP UNLESS OTHERWISE NOTED ON DRAWINGS. LOCATION OF THE WALL MOUNTED THERMOSTAT SHALL BE COORDINATED WITH OTHER TRADES FOR A NEAT APPEARANCE. FINAL LOCATION OF THERMOSTAT SHALL BE SUBJECT TO THE APPROVAL OF THE ENGINEER OR HIS REPRESENTATIVE IN THE FIELD. • ALL SUPPLY AIR DIFFUSERS SHALL BE 4-WAY THROW UNLESS OTHERWISE NOTED. • CONTRACTOR SHALL PROVIDE A COPY OF THE TEST AND BALANCE REPORT AT THE FINAL INSPECTION. THIS REPORT MUST BE REVIEWED AND APPROVED BY THE ENGINEER PRIOR TO THE FINAL ACCEPTANCE. • FLEXIBLE AND RIGID ROUND DUCT TAKE -OFFS FOR DIFFUSERS SHALL BE THE SAME SIZE AS DIFFUSER NECK. MAXIMUM FLEXIBLE DUCT LENGTH SHALL BE 8'-0". • ALL MECHANICAL WORK SHALL MEET ALL THE REQUIREMENTS OF THE "2017 FBC MECHANICAL, 6TH EDITION". • LOCATIONS OF DUCT MOUNTED SMOKE DETECTORS SHOWN ON THE DRAWINGS ARE REFERENCE LOCATIONS ONLY. THE FINAL PLACEMENT OF THE DETECTOR IN THE DUCTWORK SHALL MEET THE REQUIREMENTS OF THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. PROVIDE A PRESSURE DIFFERENTIAL TEST AND THE MANUFACTURER'S TEST KIT. A COPY OF ALL TEST DATA WILL BE MADE AVAILABLE AT THE FINAL INSPECTION. PROVIDE READILY ACCESSIBLE DUCT ACCESS DOOR FOR INSPECTING AND SERVICING THE DETECTOR. DIVISION 16 SHALL FURNISH DETECTOR, DIVISION 15 SHALL INSTALL DETECTOR, AND DIVISION 16 SHALL WIRE DETECTOR. CONFIRM SMOKE DETECTORS HAVE AUDIBLE ALARM, OR CAUSE SUPERVISORY SIGNAL TO BE INDICATED AT A CONSTANTLY ATTENDED LOCATION. PROVIDE FUNCTIONAL TEST OF FAN SHUTDOWN PRIOR TO C.O., IN ACCORDANCE WITH NFPA 90A. • ALL EXHAUST DUCTS SHALL BE GALVANIZED SHEET METAL. • PROVIDE ALL SERVICE CLEARANCES FOR ROOFTOP UNITS PER MANUFACTURERS RECOMMENDATIONS. • PROVIDE 24 VOLT AUTOMATIC DAMPERS IN ALL OUTSIDE AIR DUCTS. • COORDINATE ALL WORK WITH LANDLORD'S BASE BUILDING ROOFING CONTRACTOR, FIRE PROTECTION CONTRACTOR AND ALARM CONTRACTOR. • ALL ROOF MOUNTED EQUIPMENT SHALL HAVE PERMANENT NAMEPLATES IDENTIFYING TENANT SERVED. MECHANICAL LEGEND SYMBOL DESCRIPTION Js NEW DUCTWORK, PIPING, OR EQUIPMENT 0 0 CD RRC TGC TGC (E) FLEXIBLE DUCT DUCTWORK TRANSITION SUPPLY OR OUTSIDE AIR DUCT SECTION RETURN OR EXHAUST DUCT SECTION SUPPLY AIR DEVICE. CLEAR TRIANGLE SIDES INDICATE AIR FLOW PATTERN RETURN OR EXHAUST AIR DEVICE WALL MOUNTED THERMOSTAT MOTORIZED DAMPER SMOKE DETECTO AV PERATURE SENSOR UNDERCUT DOOR 1" CEILING DIFFUSER RETURN REGISTER AT CEILING TRANSFER GRILLE AT CEILING SUPPLY REGISTER AT CEILING EXISTING SUPPLY DUCT .,—SEE BRANCH DUCT DETAIL INSULATED ROUND FLEXIBLE DUCT (MAX. 8'-0- LONG) SIZE TO MATCH DIFFUSER NECK. ROUND METAL DUCT (EXTERNAL INSULATION) INSULATION CEILING --CEILING DIFFUSER CEILING DIFFUSER RUNOUT DETAIL NO SCALE r U Nv-I Zw� Ono „ 0 � ��� CE 00 U)co 00 rr Ln U Lu w w 0 m W Q ti xvlz=(6 U < 0 c) 9N� ON y J LL 94 I4 Engineering Professionals, Inc. Mechanical Engineers EB-0006437 1717 N. Howard Avenue Tampa, FL 33607 (813) 251-6848 101111111111t1® icl® ®®®® C:j N,•,� No.,75420 d A, E OF 4 % /3/-// SHANE R. HAMeUMN P.E. FLORIDA LICENSE #75420 0 0 0 0 CONTRACT DATE: 08.01.2018 BUILDING TYPE: N/A PLAN VERSION: N/A SITE NUMBER: N/A STORE NUMBER: N/A TENANT FINISH GALL BLVD ZEPHYRHILLS, FL 33541 FINISH PLAN PHASE 2 SCHEDULES, NOTES AND DETAILS M2 PLOT DATE: 9/07/2018 BUILDING SIGNS SIGN SIZE SIGN WT. # OF CKTS. AMPS VOLTS 3'x23' BOX 380 LBS. (1) 15 A 2.5 115 3'-9"x26' BOX 441 LBS. (1) 15 A 5 1'15 4'-6"x33'-3" BOX 750 LBS. (1) 15 A 8.4 115 5'x40' BOX 1220 LBS. (1) 15 A 10 115 BUILDING LETTERS SIGN SIZE SIGN WT. # OF CKTS. AMPS VOLTS 18" 215 LBS. (2) 15 A 19.6 115 24" 288 LBS. (1) 15 A & (1) 20 A 23.45 115 30" 387 LBS. (2) 20 A 28 115 36" 649 LBS. (2) 15 A & (1) 20 A 32.9 115 REQUIRED NATIONAL ACCOUNT VENDORS COMPANY NATIONAL CONTACT PHONE # / EMAIL BUILDING SIGNS, BUILDING LETTERS, PYLON SIGNS DUALITE SALES ROSE SHINKLE 513-724-7100 (AR, IA, IL, IN, KY, KS, LA, MI, MN, MO, MS, OH, & SERVICE (SR. PROJECT MANAGER) rshinkle@dualite.com OK, TN,TX,WI) SIGN RESOURCE IDENTITY GROUP ANGII HEIDBRINK 323-485-4720 (AZ, CA, CO, NE, NM,NV, SD, UT, WY) EVERBRITE CHRISTiNE OLSON 414-427-2329 (AL, CT, DE, FL, GA, MA, MD, ME, NC, NH, NJ, NY, PA, RI, SC, VA, VT, WV) NATIONAL ACCOUNT & CONTACT INFORMATION SUBJECT TO CHANGE LINE #1 WILL HAVE TWO RJ-11 JACKS. ONE AT REGISTER, SECOND IN THE OFFICE. LABEL AS PHONE. ALL PHONE JACKS REQUIRE A BLUE SEPARATE 24 ga. CAT 5,4 PAIR HOME RUN TO & DMARC. NOTE SEPARATE GROUND WIRES. REFER BLUE/WHITE TO SHEET E-3 FOR DETAILS,,, LEGEND (n BUZZER - TORK MODEL #TA725 W/ TRANSFORMER MODEL #TA592. QQ COMMERCIAL GRADE PUSH BUTTON 125V NEMA 5-20R DUPLEX 125/250V NEMA L14-20-R 4 PRONG TWIST LOCK 125V NEMA 5-20R QUAD `EI DISCONNECT POWER POLE - BLACK MAGIC PHONE JACK @ REGISTER VOICE/DATA PORT = 'RJ-11, RJL45 DATA JACK, PHONE COMBO @ OFFICE $M PROVIDE OCCUPANCY LIGHT SENSOR - LEVITON ODS 10-IDW 20 AMP TOGGLE SWITCH NL NIGHT LIGHT CIRCUIT ELECTRICAL SPECIFICATIONS: 1. ALL EXPOSED WIRING SHALL BE CONTAINED IN CONDUIT OF PROPER SIZE. 2. ALL WIRING SHALL CONFORM TO LOCAL, STATE, AND FEDERAL CODES. 3. ELECTRICAL SERVICE TO BE MINdMUM 400 AMP, 3-PHASE (PREFERRED) OR 600 AMP, SINGLE PHASE OR LARGER IF REQUIRED BY CODE OR ELECTRICAL LOAD. 4. REGISTER POWER POLES - VERIFY REGISTER CONFIGURATION ON FINAL FIXTURE PLAN BEFORE ORDERING AND INSTALLATION OF ELECTRICAL COMPONENTS. CUSTOM BUILT POWER POLE ASSEMBLY AVAILABLE FROM D&P CUSTOM LIGHTS & PRODUCTS INC. PHONE # (800) 251-2200 OR (615) 350-7800, 7111 COCKRILL BEND INDUSTRIAL ROAD. NASHVILLE, TN 37209 5. EXTERIOR EXPOSEDPHONE LINES TO BE INSTALLED IN RIGID CONDUIT. PROVIDE EMERSON 3/4" x 5-FT. METALLIC CABLE U-GUARD #755 OR EQUAL. 6. ELECTRIC PANELS TO BE LABELED CORRECTLY WITH LEGIBLE PRINT. 7. LOW VOLTAGE VENDOR TO PROVIDE AND INSTALL ONE (1) 24 GA., 4 TWISTED -PAIR, CATEGORY -FIVE (CAT5) DATA CABLE WITH MODULAR COMBO RJ-11/RJ/45 JACK AT MANAGER'S OFFICE. CABLE TO BE RUN FROM JACK TO DATA HUB LOCATION WITH 6'-0" LEFT COILED FOR INSTALLATION TO DATA HUB. A RJ-45 MALE FITTING SHOULD BE CRIMPED ON THIS END. DOLLAR GENERAL STORE OPENING TEAM WILL MAKE FINAL CONNECTION INTO THE DATA HUB. 8. SEE SHEET F1 FOR COOLER/FREEZER OPTIONS. VERIFY FINAL LOCATION AND NUMBER OF COOLERS AND FREEZERS ON FINAL FIXTURE PLAN BEFORE ORDERING AND INSTALLATION OF ELECTRICAL COMPONENTS. EACH COOLER REQUIRES A 20 AMP DEDICATED GROUND CIRCUIT TO BE USED FOR A 110v OUTLET. EACH OF THESE UNITS DRAW 12 AMPS. EACH FREEZER REQUIRES ONE - 125/250V OUTLET NEMA #1_14-20 w/ 4 PRONG TWIST LOCK. EACH UNIT DRAWS 16 AMPS. TWO DOOR FREEZER IN RECEIVING AREA REQUIRES ONE 125/250V NEMA 14-20R OUTLET ON A 20 AMP DEDICATED CIRCUIT. UNIT DRAWS 8 AMPS. PYLON SIGNS SIGN SIZE SIGN WT. # OF CKTS. AMPS VOLTS 4W' 188 LBS. (1) 15 A 1.7 115 5'x10' 375 LBS. (1) 15 A 3.4 115 6'x16' 738 LBS. (1) 15 A 5 115 NOTES: 1. PROVIDE AND INSTALL CONDUIT, JUNCTION BOXES, D&P CONNECTORS AND/OR POWER POLE(S) FOR CASH REGISTER(S), VERIFY LOCATION OF JUNCTION BOXES WITH TENANT'S FIXTURE FLOOR PLAN PROVIDED BEFORE TURNOVER DATE. 2. PROVIDE AND INSTALL POWER POLE(S) FOR REGISTERS AND ICE CREAM FREEZER. 3. PROVIDE AND INSTALL POWER POLES FOR REFRIGERATION UNITS. 4. VERIFY LOCATION OF POWER POLES WITH TENANT'S FIXTURE FLOOR PLAN PROVIDED BEFORE TURNOVER DATE. 5. PROVIDE AND INSTALL ELECTRICAL RECEPTACLES. 6. PROVIDE AND INSTALL BREAKER LOCKS ON THE FOLLOWING: REGISTER POWER POLES, SALES FLOOR COOLERS AND FREEZERS, RECEIVING/SALES NIGHT LIGHTS, SECURITY OUTLETS, OUTDOOR ICE MERCHANDISER, AUTOMATIC DOORS, TELEPHONE BOARD, DOOR BUZZER, OFFICE RECEPTACLES, OFFICE LIGHTS, BREAK ROOM, RESTROOMS AS SHOWN ON PANEL LAYOUT, 7. FULLY LABEL ALL PANEL SCHEDULES ACCURATELY AND LEGIBLY. HAND WRITTEN LABELS NOT ACCEPTABLE &PROVIDE AND INSTALL CONDUIT FROM PANEL TO NEW BUILDING SIGN LOCATION, TERMINATING IN A JUNCTION BOX TO BE CENTERED HORIZONTALLY ON TENANTS PROPOSED SPACE AND VERTICALLY ON THE CANOPY. PROVIDE 208V, 1 PHASE CONNECTION T A J-BOX AT 90" AFF WITH 3 #10 CU. & #10 GROUND IN 4'C. R.C. TO PROVIDE AND INSTALL 30A/2NF DISCONNECT SWITCH AND WIRE FROM DISCONNECT SWITCH TO � DAI 1 I EQUIPMENT CONNECTIONS. °`« A-29 - — m (E) RTU-1 A-22. `PROVIDE NON FUSED R-21,23 DISCONNECT AT W.H. FIELD LOCATE BUZZER. PROVIDE 2 NO 12 AWG CU AND I NO 12 AWG CU EQ GND IN 1/2" E C. TO BUZZER PUSHBUTTON AT Hummm0mgm RECEIVI -- UNDERGROUND SERVICE LATERAL. SEE POWER DISTRIBUTION RISER DIAGRAM FOR ADDITIONAL INFORMATION. A-8 A-7,9,11 TE _EPHO E CONDUIT ST JB THROUGH WALL. 1 RTU-2 EXISTING PULLBOX EXISTING CT CABINET PANEL "R" PANEL "B" 0 0 0 DUPLEX OUTLET DEDICATED CKT R-39 PANEL "A" R-2,4 PANEL EMS,HVAC & LTG PANEL HVAC CONTROL mm KNOX BOX FOR FIRE DEPT ACCESS BUZZER PUSH BUTTON 60 AMP., 240VAC, 3 WIRE (3 BLADES) SAFETY SWITCH IN A NEMA 3R ENCLOSURE. 3 NO 8 AWG THWN CU AND 1 RTU-3 NO 10 AWG THWN CU EQUIPMENT GROUND IN 3/4" CONDUIT. AVOID ROUTING CONDUIT ABOVE ROOF TO THE i GREATEST EXTENT A-13,15,17 PRACTICABLE. E 125V NEMA 5-20R DUPLEX R-14,16 R-6,8 R-10,12 WEATHERPROOF GFCI RECEPTACLE WITH IN -USE COVER (TYPICAL OF 5) USE 2 NO 12 AWG THWN CU AND 1 NO 12 AWG THWN CU EQUIPMENT GROUND IN 3/4" CONDUIT. AVOID ROUTING CONDUIT ABOVE ROOF TO THE GREATEST EXTENT PRACTICABLE. 9. PROVIDE AND INSTALL A TIMER AND PHOTOCELL COMBINATION. ROUTE THE FOLLOWING CIRCUITS THROUGH THE TIMER/PHOTECELL ASSEMBLY: PYLON SIGN, BUILDING SIGN, PARKING LOT LIGHTS, WALL PACKS, AND CANOPY LIGHTS 10. PROVIDE AND INSTALL 1" CONDUIT WITH PULL STRING ABOVE THE MANAGER'S OFFICE WITH ROOF OR WALL PENETRATION FOR VSAT (TENANT SATELLITE). COORDINATE EXACT LOCATION WITH TENANT CONSTRUCTION DEPARTMENT PROJECT MANAGER. 11. PROVIDE AND INSTALL CONDUIT WITH PULL STRINGS AT MANAGER'S OFFICE, CASH, REGISTER AREA AND DMARC PANEL. COORDINATE EXACT LOCATION WITH TENANT CONSTRUCTION DEPARTMENT PROJECT MANAGER, 12. PROVIDE 1" CONDUIT FROM OFFICE TO CENTER OF SALES AREA TERMINATING WITH A JUNCTION BOX. HOLD CONDUIT TIGHT TO STRUCTURE. WAP MOUNTED AT 12'-0" AFF, 13. PROVIDE AND INSTALL CONDUIT FROM PANEL, THROUGH BUILDING, AND UNDERGROUND TO PYLON SIGN LOCATION. STUB UP CONDUIT 12" ABOVE GRADE AT PYLON LOCATION, CAP AND MARK WITH 36" HIGH STAKE. 14. LOW VOLTAGE VENDOR TO PROVIDE AND INSTALL 24 GA., 4 TWISTED -PAIR, CATEGORY -FIVE (CATS) DATA CABLE WITH MODULAR COMBO RJ-11/ RJ-45 JACK AT MANAGER'S OFFICE. CABLE TO BE RUN FROM JACK TO DATA HUB LOCATION WITH 6' LEFT COILED ABOVE CEILING FOR INSTALLATION TO DATA HUB. AN RJ-45 MALE FITTING SHOULD BE CRIMPED ON THIS END, DOLLAR GENERAL STORE OPENING TEAM WILL MAKE FINAL CONNECTION INTO THE DATA HUB, R-1,3 R-5,7 PROVIDE 208V, 1 PHASE CONNECTIO T A J-BO AT 90" AFF WITH 3 #12 CU. & #12 GROUN IN 4'C. R C. TO PROVIDE AND INSTALL 30A/2NF D ONNE SWITCH AND WIRE FROM DISCONNE SWITCH TO EQUIPMENT CONNECTIONS._„ `'1'.'�:'.`.\:.�\'.\". \ `�'�''C[��''\i'l �\.F�.`c`. '�'.ci`'cC :\ `='F''i-\'�:`u`,F<'[?`...'«'e'.�'r `ram. .._....., � �.-:-�•..,, �> -'• -h -_--._.�.___...__.__...--- --_.�.__-. _'-__ _ -�- J PROVIDE 208V, 1 PHASE CONNECTION T A J-BOX AT R-9,11 1 90" AFF WITH 3 #8 CU. & #10 GROUND IN 1"C. R.C. RA3,15 R-17,19 TO PROVIDE AND INSTALL 60A/2NF DISCONNECT SWITCH AND WIRE FROM DISCONNECT SWITCH TO f EQUIPMENT CONNECTIONS. A-41 SO CORD (WHITE), WITH COORDINATE EXACT QUAD RECEPTACLE. ANCHOR TO PURLINS POWER REQUIREMENTS ABOVE (TYPICAL, 5). WITH SIGN VENDOR. REFER TO CHARTS SHOWN ON THIS SHEET. DUPLEX RECEPTACLE FOR A-37 GATORADE COOLERS. GFI RECPT. FOR ICE A-18 MERCH @ 4 -0"" A.F.F. A-26 A-24 A-20 ! B-23 i GFI RECPT. FOR SODA f� MERCH. @ 4'-0" A.F.F. CIRCUITS ROUTED DOWN 14'-0" POWER A-2,4,6 POLE TO EQUIPMENT. PROVIDE AND HEAVY DUTY, 12"X 20" (E) RTU-4 INSTALL RECEPTACLES (NEMA 5-20R) FOR RTU-5 SHELF (BY G FOR COOLERS, AND REGISTERS. SEE FIXTURE VSAT & DA HUB PLAN SHEET (F1) EQUI II ENT. REGISTE TO DMAR POWER A-10,12, TO REGISTE B-30, 32, 34, 36, 38,40,42,44 . �_ DED. QUAD. RECPT. @ 3'-0" #P3AC24-16-8L, 16 CAMERA, 24 VAC, 8 AMP, POWER SUPPLY CABINET. ----� L- FOR RTU-3 AND 5: - DED. QUAD. RECPT. @ B 8 125/250V NEMA L 14-20-R 100�AMP., 240VAC, 3 WIRE (3 BLADES) SAFETY SWITCH IN A NEMA 3R ENCLOSURE. 3 NO 3 3'-0" FOR CCTV EQUIP. AWG THWN CU AND 1 NO 8 AWG THWN CU EQUIPMENT GROUND IN 1-1/4" CONDUIT. AVOID A-27 #BW-106 VIDEO 4 PRONG TWIST LOCK ROUTING CONDUIT ABOVE ROOF TO THE GREATEST EXTENT PRACTICABLE. IT IS \1 CONVERTER ENCLOSURE. PREFERRED TO BE ROUTED BELOW ROOF. LOW VOLTAGE VENDOR TO PROVIDE AND INSTALL 24 GA., 4 TWISTED -PAIR, CATEGORY -FIVE (CAT5) DATA CABLE WITH MODULAR COMBO RJ-11/ RJ-45 JACK AT MANAGER'S OFFICE. CABLE TO BE RUN FROM JACK TO DATA HUB LOCATION WITH 6' LEFT COILED ABOVE CEILING FOR INSTALLATION TO DATA HUB. AN RJ-45 MALE FITTING SHOULD BE CRIMPED ON THIS END. DOLLAR GENERAL STORE OPENING TEAM WILL MAKE FINAL CONNECTION INTO THE DATA HUB. PROVIDE DATA CABLE TO *NOTE: BEFORE ORDERING AND INSTALLATION OF ELECTRICAL COMPONENTS FOR COOLERS, FREEZERS, AND REGISTERS, CONSULT FINAL FIXTURE PLAN FOR NUMBER AND LOCATION. IF CEILING HEIGHT IS ABOVE 10', COMMUNICATE WITH D&P WHEN ORDERING FOR PROPER POWER POLE HEIGHT. MAXIMUM NUMBER OF CIRCUITS FOR COOLERS/FREEZERS IN SALES AREA - (5) 110v AND (3) 220v MAXIMUM CIRCUITS FOR REGISTE§RS - CIRCUITS AT MAIN REGISTER - (8) 110v CIRCUITS AT ISLAND REGISTER - (3) 110v FLOOR PLAN - POWER & DATA NOT roSCALE EACH REGISTER AND ALL DEVICES REQUIRING DATA. ROUTE CABLES TO DATA HUB. *NOTE: VERIFY FINAL LOCATION OF ALL ELECTRICAL WITH THE FINAL FIXTURE LAYOUT PLAN PROVIDED BY STORE PLANNING. A-35 B-4- QUAD RECEPTACLE FOR COSMETICS VALANCE. z j x �O 0° I w Z I A 39 Q z z B-23 v5 i O H VOICE/DATA/VSAT CONDUITS. z 0 DED. QUAD. RECPT. @ 6'-0" FOR VSAT, DATA HUB EQUIP. INTERFACE EQUIPMENT REQUIRES \48" WIDE CLEAR WALL SPACE. INTERFACE ALARM PANEL SECURITY RECPT. @ T-0" A.F.F. FIRE ALARM EQUIP. PANEL RECEPT. @ l'-6" A.F.F. lid H r� V Z W d- A p oLn a C110�co w � � cn00 Fz�-Q� LI �xUcC=cn —'zgco ��� ON LL a o U O U � co co CUr J N cn Co t- J CO ,It t o w L CO d LN O O _O � co O Qcco 0 o 0- co ro�.a) w o U) c000 E 6z WU)NN"Q UM �_ U) aIU) o of ° U- 1� o C � r44 4 0) m N a_ 0 0 0 0 0 0 CONTRACT DATE: 08.01.2018 BUILDING TYPE: N/A PLAN VERSION: N/A SITE NUMBER: N/A STORE NUMBER: N/A TENANT FINISH GALL BLVD ZEPHYRHILLS, FL 33541 FINISH PLAN PHASE 2 FLOOR PLAN - POWER & DATA E1 PLOT DATE: NEW CEILING GRID EXISTING CEILING GRID CABLE TRAY MATERIALS LIST BASKET TRAY WHITE LINER ROLLS SPLICE KITS SPLICE KITS TEE'S RADIUS PURLIN SPEED CLIPS LINKS 0 FEET 3 2 2 0 0 60/70 60/70 GRAYBAR JEROME BANNISTER 615-743-3202 dollargeneral@graybar.com CABLE TRAY NOTES: 1. CABLE TRAY TO BE MOUNTED SUCH THAT THE BOTTOM OF TRAY IS ABOVE SALES AREA LIGHTS. 2. CABLE TRAY SYSTEM TO BE INSTALLED USING FULL LENGTHS WITH MINIMAL CUTTING OF SECTIONS. 3. GENERAL CONTRACTOR SHALL PROVIDE AND GC's ELECTRICIAN SHALL INSTALL CABLE TRAY AND ALL CONDUIT WITH PULL STRINGS AS REQUIRED. INSTALLATION MUST BE COMPLETED PRIOR TO DAY (1) ONE OF FIXTURING OR LEASE DELIVERY DATE, WHICHEVER IS EARLIER. LIGHT FIXTURE DESCRIPTION SYMB TYPE MANF. PART # DESCRIPTION CNT o A LEDS LSPRO LBAR 48 CW80 4' LED STRIP. (1) 5FT. VERTICAL POWER CABLES AND 100 30W FR MVOLT (1) 8FT. HANGER CABLE, POWER SUPPLY NOT INCL.) O Al LEDS 6" LED ROUND CAN WITH L-TRIM, WHITE 0 O B LEDS 6" LED ROUND CAN WITH L-TRIM, WHITE 0 X C EXITRONIX VEX-U-BP-WB-WH LED EXIT SIGN 0 D EXITRONIX VLED-U-WH-EL90-R EMERGENCY LIGHT/EXIT 0 COMBO 2 HEADS E EXITRONIX LED-90 EMERGENCY LIGHT 0 2 HEADS F EXITRONIX CLED-WP EMERGENCY EGRESS 2 LIGHT 1 HEAD ® G TECH LIGHT LHSWP WALL PACK 6 n HILUMZ WMUPS42 HILMUZ FLOOD u TECH LIGHT HN15-150-50K-D3N-B TECH LIGHT ARM HILUMZ (2)HN15-150-50K-D3N-P PARKING LOT LIGHT S 0 TECH LIGHT SS3P 24 4 11 BZ DM2 180 24' LIGHTING POLE HOOKER HANGER TO BE USED TO MOUNT LIGHT FIXTURES TO CEILING GRID. HUBBELL - CSZT LITHONIA LIGHTING - HRC1J48. MICHAEL STRINGER/ BRIAN VAN ROY 920-915-4010 DGorders@leds-Ilc,co LEDS TERRITORY: (AL, AZ, CA, CT, DE, FL, GA, LA, MA, MD, ME, MS, NC, NH, NM, NJ, NV, NY, OR, PA, RI, SC, TN, TX, VA, VT,) LIGHTING SPECIFICATIONS: 1. RECEIVING AREA LIGHTS, IF NOT INDICATED ON SHEET'E2', TO BE SPACED EVENLY FROM FRONT AND REAR WALL OF RECEIVING AREA. 2. NIGHT LIGHTING: INCLUDES THREE LIGHT FIXTURES IN CENTER ROW OF SALES AREA AND AT LEAST ONE FIXTURE NEAR ELECTRIC PANELS AND EMERGENCY EXIT DOOR IN RECEIVING AREA. ADDITIONAL LIGHT FIXTURES MAY BE REQUIRED TO PROVIDE MINIMAL LIGHTING FROM ENTRY TO ELECTRICAL BREAKER PANEL. NIGHT LIGHTING TO HAVE ITS OWN DEDICATED CIRCUIT. 3. EMERGENCY / EXIT SIGNS AND LIGHTS: INSTALL EMERGENCY LIGHTS AND SIGNS THROUGHOUT THE BUILDING IN COMPLIANCE WITH ALL APPLICABLE CODES. 4. ALL LIGHTING HOMERUNS TO BE RAN TO EMS LIGHTING CONTACTOR PANEL. SEE SHEET E4, PREFERRED PANEL LAYOUT DETAIL FOR ADDITIONAL INFORMATION REGARDING LIGHTING CONTROL. B-43 `" 30" RADIUS B-13 3 RADIUS B-13 EN I ! I MENA--� B`1 5 TTACH17, B-15 B-15 B-15 B-15 B-15 B-15 B-15 B-15 B-15 E SPEAKER B-13 ( HAB-13 B-13 o TO TRAY ____--_------_.-- B-13 B-13 B-13 B-15 B-1 LIJ J B-15 Q B-15 B-15 B-15 B-15 B-15 B-15 B-1 B-41 B-13 B-13 B-13 1 ?--� .5 G1, ` J m z ¢ B-15 � W rfN W o T-2" M B-3-- ; i B-7 B- I L===3 GI 1" CONDUIT B-41 FROM TRAY TO EMS PANEL- m 0 E I B-3 Eo B-7 i SALES �I E B-7 B-1 A B-7 AREA B-1 B-7 B-1 10'-0° B-7 i I B-3 - B-7 � 102 B-7 Dil I B-3 E �h B-1 E in B-3 RECEIVING AFSE51,'t B-1 NIGHT LIGHT B 1i )FG %0B-1 1 B 1 B-1 0 NIGHT LIGHT IJ B-3 30" TEE J B-5 II M � N TTACH 7PEAKER TRAY B-3 B-41 B-11 E B-11 NIGHT LIGHT B-9 B-9 B-5 B-5 CLG. HT.OPEN LTG. 1l'-0" NIGHT LIGHT B-9 B-9 A- L=== B-5 B-5 B-5 B-5 B-5 B-5 6=== A- L=== B-9 B-9 B-9 B-9 B-9 I� B-9 a _E �B-9 B-9 B-11 LOCKED A3 STORAGE 108 CLG. HT.OPEN LTG. 11'-0" : v 4 B-41 NIGHT LIG TF - 30" TEE CENTER ON ! i ENTRY DOORS B-9 I B-9 B-9 16'-0" MAX. - I — CCTV +I A� - LOCATION_ I LOCATION OF OFFICE B-5 B-5 HUB BELOW. BUNDLE 1� ALL WIRES AND RUN B-5 L TO CABLE TRAY-----, L5f-l4"t 30" TEE B-5 I; OFFICE B-5 1 i 101 B-5 TE 13�'m B-1 LUMINAIRES IN OFFICE 101 AND BREAK ROOM 100 SHALL BREAK BE SUSPENDED AT 10 -0 AFF. ROOM = � 9 B-9 B-9 B-9 ATTACH ) -13 B-13 j PEAKER TO TRAY 1 �_ II' B-13 B-9 B-11 B-1 E FLOOR PLAN - LIGHTING & CEILING EQUIPMENT. NOT TO SCALE B-11 B-7 t A B-11 (j 1 o ff� 1 , U Z d' w AO� co oDLo 0 NU�� ULIJW�L00 0 H uj UQZ0c) N CC 71- I�pcv (A ILL ;Q o4 � � O UU corn co co co USE �(D Lu O 1 O � 2 NcV Q0c0 c\I Oz Lu a)O co , a)O . ccf) �UT� �o)o O QW U) N� U ca T �N � U N — LL 1� o C 2E �- o J C . C N FA 0 0 0 0 0 CONTRACT DATE: BUILDING TYPE: PLAN VERSION: SITE NUMBER: STORE NUMBER: 08.01.2018 N/A N/A N/A N/A -- a-- TENANT FINISH GALL BLVD ZEPHYRHILLS, FL 33541 FINISH PLAN PHASE 2 FLOOR PLAN - a�;y$}$(°� LIGHTING & CLG. EQ. t gL�Ys ♦RtlPe "¢ i� E2 "�A �� PLOT DATE: DEDICATED LINE FOR DG PLUS ONLY REQUIRED ACCOUNT VENDORS COMPANY CONTACTS PHONE # LOW VOLTAGE & VOICE/DATA CROSSCOM NATIONAL ANDREA LEMAY 847-850-6297 dollargeneral@crosscomnational.com CO, CT, DE, FL, IA, IL, IN, KS, MA, MD, ME, MI, MN, MO, ND, NE, NH, NJ, NY, OH, PA, RI, SD, VT, WI, WV ASD 828-624-1046 CHRIS RUDNITSKI crudnitski@asd-usa.com AL, AR, AZ, CA, GA, KY, LA, MS, NC, NM, NV, OK, OR, SC, TN, TX, VA NOTE-1 CONDUIT RESPONSIBILITY CONDUIT START END SIZE CONDUIT RESPONSIBILITY *CABLING RESPONSIBILITY NUMBER 1 RECEIVING AREA OFFICE (HUB) 2" GENERAL CONTRACTOR LOW VOLTAGE VENDOR 2 OFFICE OFFICE (HUB) 11" GENERAL CONTRACTOR LOW VOLTAGE VENDOR VOICE / DATA PORT 3 SALES FLOOR OFFICE (HUB) 1"" GENERAL CONTRACTOR LOW VOLTAGE VENDOR REGISTER CONNECTION SALES FLOOR 4 QUADRANT OFFICE (HUB) 1"" GENERAL CONTRACTOR LOW VOLTAGE VENDOR CONNECTION 5 SATELLITE OFFICE (HUB) 1-1/4" GENERAL CONTRACTOR LOW VOLTAGE VENDOR *UNLESS OTHERWISE NOTED, ALL RESPONSIBILITIES SHOULD FOLLOW THIS CHART. ALL LOW VOLTAGE WIRING INSTALLED IN CABLE TRAY FOR OPEN CEILING LAYOUTS. ELECTRICAL, DMARC AND EMS PANELS IN RECEIVING AREA. 2" CONDUIT FROM RECEIVING TO DATA VOICE PORT 1-1/4" CONDUIT FROM SATELLITE TO OFFICE HUB - VOICE / DATA 1" CONDUIT FROM VOICE DATA PORT TO OFFICE HUB AT EQUIPMENT MAP - OFFICE HUB AT EQUIPMENT MAP NOTE: ALL CONDUITS WITH PULL STRINGS INSTALLED BY GENERAL CONTRACTOR ALL CABLES AT THE OFFICE WILL NEED TO BE WRAPPED IN PHASING TAPE CONSISTENT WITH THE FOLLOWING COLORS: RED TAPE CASH REGISTER DATA BLUE TAPE ELEC. EMS DATA BROWN TAPE OFFICE DATA 9 LO j O " :TY p LO U cr) cD J �- n CD c� i) LL U O w a 1" CONDUIT FROM O N O SALES FLOOR a) = Q � c Q w QUADRANTS TO O O Co ,- N p ul OFFICE HUB O U -0 a) O Z w v 0 - W U 1" CONDUIT FROM w Q. w -' SALES REGISTER t� U .c 0 CONNECTION TO OFFICE HUB r a)� N prr 0 p (O (Q 0 0 LL LL TYPICAL FLOOR PLAN NOT TO SCALE ORANGE TAPE COOLER/FREEZER EMS DATA Wire Symbols RJ-45: 24 GA., 4 TWISTED PAIR, CATEGORY -FIVE (CAT 5) DATA CABLE WITH MODULAR RJ-45 END. RJ-11: 24 GA., 4 TWISTED PAIR, CATEGORY -FIVE (CAT 5) DATA CABLE WITH MODULAR RJ-11 END, USE ONLY THE BLUE & WHITE AND SOLID BLUE WIRES. ALL OTHER WIRES TO BE FOLDED BACK AND TAPED TO THE CABLE. COAXIAL CABLE WITH RF CONNECTOR GENERAL CONTRACTOR NOTE: EXPANSIONS AND RELOCATIONS REQUIRE THE GENERAL CONTRACTOR TO PROVIDE THE MATERIALS AND LABOR INDICATED ON THIS DIAGRAM AS BY "LOW VOLTAGE INSTALLER" IN ADDITION TO CONDUITS INDICATED. DOLLAR GENERAL DOES NOT PROVIDE AND/OR INSTALL THE LOW VOLTAGE AND DATA CABLING ON THOSE PROJECTS. DATA CABLING SCHEMATIC_ NOT TO SCALE���, f�Jet No �t ;0 a r fitIS E OF dot A,I " o-, 1� 0 m n 16009 CONTRACT DATE: 08.01.2018 BUILDING TYPE: N/A PLAN VERSION: N/A SITE NUMBER: N/A STORE NUMBER: N/A TENANT FINISH GALL BLVD ZEPHYRHILLS, FL 33541 FINISH PLAN PHASE 2 ENERGY MANAGEMENT SYS. E3 PLOT DATE: PANEL'A', 120/208 VOLT, 3 PHASE, 4 WIRE, 600 AMP, 600A MCB, SURFACE MOUNT, NEMA 1 TOTAL PER PHASE IN WATTS C#KT DESCRIPTION AMP POLE A B C AMP POLE DESCRIPTION CKT 1 09660 2 SPARE 25 3 100 3 HVAC UNIT#5 3 09660 4 5 0 6 9660 7 5007900 20 1 REC - ROOFTOP MAINT. 8 HVAC UNIT #2 45 3 9 5007516 20 1 REC- MT DEW REGISTERS 10 1500 20 1 REC - COKE REGISTERS 12 516 13 9660516 20 1 REC - PEPSI REGISTERS 14 HVAC UNIT #3 100 3 15 966000\\ 20 1 SPARE (EXHAUST FAN EF2) 16 17 9660516 20 1 GATORADE DRINK COOLER 18 19 0 20 1 AUTOMATIC DOOR 20 SPARE 100 3 250 21 0 20 1 TELEPHONE BOARD / 22 100 BUZZER 23 0 20 1 RECEPT.- FRITO EC 24 516 25 20 1 20 1 RECEPT. - STARBUCK EC 26 516 27 RECEPTACLE -BEAUTY 20 1 360 20 1 ENERGY MANAGEMENT 28 29 DRINKING FOUNTAINS 20 1 500 20 1 SPARE 30 31 OUTDOOR ICE 20 1 864 32 MERCHANDISER 150 3 PANEL "R" 33 SPARE 20 1 34 35 REC - VSAT DATA HUB 20 1 360 36 37 MOUNTAIN DEW ENDCAP 20 1 516 150 3 PANEL "B" 38 39 SODA COOLERS 20 1 516 40 41 COKE ENDCAP 20 1 360 42 NEW TOTAL CONNECTED = 80,803VA + 43,598VA+ * HANDLE LOCK -ON DEVICE TOTAL 10,185 VA = 134,586 / 360 = 374A @ 208V., 3PH PANEL A NOTES: 1. PANEL A TO BE SERVICE ENTRANCE RATED WITH AIC RATING OF 65K MINIMUM. 2. BREAKERS FOR HVAC UNITS SHALL BE SIZED PER MANUFACTURER REQUIREMENTS. VERIFY ALL WIRES SHOWN TO MEET LOCAL CODES. ADJUST, AS REQUIRED, PER LOCAL CODES. PANEL LAYOUT SHOWN ON THIS SHEET IS PREFERRED INFORMATION. EXTERIOR LN INTERIOR EXISTING INSTRUMENT RATED METER BASE AND METER BY UKE ENERGY WITH 1/14" PVC CONDUIT. DUKE El E Y TO PROVIDE AND INSTALL CT'S AND CONDUCTORS FROM METER BASE TO NEW CT'S. — NEW 60 AMP., 3 PHASE SERVICE ENTRANE CONDUCTORS - 2 SETS OF (4) #350 CMIL THWN CU IN 3"C 1 600 AMP., 3 PHASE SERVICE ENTRANCE CONDUCTORS - 2 SETS OF (4) # 350 KCMIL THWN CU, 3"C. 42,218 AIC AT CT CABINET. PROVIDE AND INSTALL 1 NO 1 AWG THWN CU BONDING CONDUCTOR BETWEEN PULL BOX, PNL A BONDING BUSHINGS. PNL A PNL R • N PNL B —N 150A, 3 PHASE - (4) #1 /0 THWN CU, (1) #6 AWG THWN CU EQUIPMENT GROUND, 2"C PREFERRED PANEL LAYOUTS PANEL'R', 120/208 VOLT, 3 PHASE, 4 WIRE, 225 AMP, MLO, SURFACE MOUNT, NEMA 1 TOTAL PER PHASE IN WATTS DESCRIPTION DESCRIPTION I XMIN S, EXEN, FREEZER - 5 DOOR WAREHOUSE FREEZER - 3 DOOR EXE EXE COOLER - 5 DOOR ICE CREAM FREEZER - 3 DOOR N I 0 a 8 Ar, OXEN EXEN" COOLER - 5 DOOR FREEZER - 4 DOOR OXEN ' I EXEN, I COOLER - 4 DOOR FREEZER - 4 DOOR EXEN" OXEN' NXENEXEN COOLER - 4 DOOR Ml WATER HEATER SPARE (CONDENSER SKID B) EXEN" MEMO m m m m MEMINNEEMNMENNIME ''I'll m m m 0 EXEN■o..m���■■gym NXEN, m 0 ■gym■� SPARE (SCISSOR LIFT) m WAREHOUSE COOLER - 3 DOOR III MEMO 111 I'll, M. NEXNEI REFRIGERATION CONTROL PNL w 1 001' MEN m TOTAL i HANDLE LOCK -ON DEVICE @ 208V., 3 PHASE PANEL R NOTES: 1. PANEL R TO HAVE AIC RATING OF 10K MINIMUM AND SERIES RATED WITH 65K AIC OF FEEDER BREAKER IN PNL A. 2. - 3. PROVIDE & INSTALL 1 AND 2 POLE BREAKERS FOR COOLERS/FREEZERS AS PER FINAL FIXTURE PLAN - WILL NOT EXCEED 40 AMPS ON DOUBLE POLE BREAKERS. SINGLE POLE CIRCUITS WILL NOT EXCEED 30 AMP. 4. FIELD COORDINATE ALL BREAKER SIZES WITH MANUFACTURER EQUIPMENT. SIZES MAY VARY FROM ZERO ZONE TO KYSSOR WARREN. 5. SHADED DESCRIPTIONS DENOTES ROUTING TO THE EMS PANEL SERVICE SIZE SHOWN IS BASED ON GAS HEAT. FOR STORES WHERE ELECTRIC HEAT IS USED, THE FOLLOWING ITEMS ARE TO BE USED: • FUSE AT DISCONNECT TO BE INCREASED TO 600A AND/OR MAIN BREAKER IN PANEL "A" TO BE INCREASED TO 600A • SERVICE WIRE FROM UTILITY AND TO PANEL "A" TO BE CHANGED TO 2 SETS OF (4)#350KCMIL, 3"C., COPPER. MAIN BONDING JUMPER BARE COPPER CONDUCTION MINIMUM OF 20'-0" OF 1/2" REBAR IN BUILDING WALL FOOTING, (NEC 250-50C) - CADWELD OPTIONAL FOR EXISTING SLAB LIFER. 3/4" X 1O' GROUND ROD (NEC 250-52) COLD WATER SERVICE ENTRANCE (PROVIDE SIMILAR CONNECTION TO FIRE PROTECTION WATER SERVICE ENTRANCE), (NEC 250-50A) 2/0 SERVICE GROUNDING ELECTRODE CONDUCTOR TO TWO (2) 8" DIAM X 104" LONG COPPER -CLAD GROUND RODS AND AVAILABLE FOOTING REBAR, METAL WATER PIPE AND BUILDING STRUCTURAL STEEL, PER NEC 250.66. LOCATE I GROUND AT PANEL "A". EXISTING PILL BOX. PROVIDE AND INSTALL NEW COVER WITH SCREWS AND BONDING BUSHINGS. BOND TO BOX AND CT CABINET. EXISTING CT CABINET, DUKE ENERGY TO INSTALL NEW CT'S AND CONNECT COMPLETE. PROVIDE AND INSTALL BONDING BUSHINGS. BOND TO CABINET AND TO PULL BOX WITH. 600 AMP., 3 PHASE SERVICE UNDERGROUND SERVICE ENTRANCE CONDUCTORS - TWO (2) SETS OF 4 NO 350 KCMIL THWN CU EACH IN A 3" PVC CONDUIT. SAW CUT ASPHALT/CONCRETE FROM DUKE ENERGY UTILITY TRANSFORMER TO EXISTING CT CABINET. PATCH TO MATCH EXISTING. POWER DISTRIBUTION RISER DIAGRAM NEUTRAL BUS -ITIGROUND BUS VALVE, METER OR UNION JUMPER T SUPPLY SIDE PIPE CLAMP (TYP. ) NOTE: ALL GROUNDING SHALL BE INSTALLED IN ACCORDANCE WITH ARTICLE 250-50 OF THE NATIONAL ELECTRICAL CODE. 2 GROUNDING DETAIL E4 SCALE: NTS (1 #6 TO PHONE BOARD PER NEC 800-40(D) BARE COPPER GROUNDING ELECTRODE CONDUCTOR (NEC 250-66) BONDING JUMPER TO PANELBOARD ENCLOSURE SIZE PER NEC 250-122 —BUILDING STRUCTURAL STEEL (NEC 250-52(A)(2) CADWELD 2 REFRIG. CONTROL PANEL FLOOR LINE EMS, HVAC & LIGHTING O 4 • DMARC PANEL'S', 120/208 VOLT, 3 PHASE, 4 WIRE, 225 AMP, MLO, SURFACE MOUNT, NEMA 1 TOTAL PER PHASE IN WATTS C#KT DESCRIPTION AMP POLE A B C AMP POLE DESCRIPTION C#KT ONIGHT LIGHTS 20 1 120 20 1 RECEPT. - DEDICATED QUAD 2 360 RECEIVING LIGHTS 20 1 180 360 20 1 RECPT. - INTERFACE EQUIP. 4 5 70%SALES LIGHTS - ROW 2 & 3 20 1 420 540 20 1 OFFICE RECPT. 0 7 70% SALES LIGHTS - ROW 5 & 6 20 1 450 360 20 1 RECEPT. - CCTV EQUIP 8 9 30% SALES LIGHTS - ROW 1 & 4 20 1 540 20 1 SPARE 10 11 ALES LIGHTS - STORAGE /ENT 20 1 240 20 1 SPARE 12 13 BREAK RM/OFFICE/R.R. LIGHTS 20 1 480 20 1 BULKHEAD RECPT. 14 15 1777777777//// 30% SALES LIGHTS - ROWS 7 & 8 20 1 570 20 1 SPARE 16 17 SPARE 20 1 20 1 SPARE 18 19 SPARE 20 1 25 1 SPARE 20 21 SPARE 20 1 25 1 SPARE 22 23 BUILDING SIGN 20 1 1200 25 1 SPARE 24 25 PYLON SIGN 20 1 20 1 SPARE 26 27 20 1 SPARE 28 SITE LIGHTING 20 2 29 20 1 POWER TERMINAL BROWN 30 360 31 SPARE 20 1 20 1 POWER TERMINAL BROWN711177-111 32 360 33 SPARE 20 1 360 20 1 POWER TERMINAL GREEN 34 35 ol SPARE 20 1 20 1 POWER TERMINAL GREEN 36 360 37 SPARE 20 1 360 20 1 POWER TERMINAL GREEN 38 39 SPARE 20 1 360 20 1 POWER TERMINAL GREEN 40 41 EXTERIOR DUSK/DAWN 20 1 348 360 20 1 POWER TERMINAL BROWN 42 43 SPARE 20 1 20 1 POWER TERMINAL BROWN 44 360 45 SPARE 20 1 20 1 SPARE 46 47 SPARE 20 1 20 1 SPARE 48 49 SPARE 20 1 20 1 SPARE 50 51 SPARE 20 1 20 1 ICE CREAM FREEZER 52 53 SPARE 20 1 20 1 GATORADE 54 NEW (X), EXISTING () TOTAL TOTAL CONNECTED = LTG 5,685VA + 4,500VA = " HANDLE LOCK -ON DEVICE 1 10,185 / 360 = 28A @ 208V., 3 PHASE PANEL B NOTES: 1. PANEL B WITH AIC RATING OF 10K MINIMUM SERIES RATED WITH 65K AIC FEEDER BREAKER IN PNL A. 2. HATCHED DESCRIPTIONS DENOTES ROUTING TO THE EMS PANEL. 3. PANEL HAS BOTH AN ISOLATED GROUND BUS AND A STANDARD BONDED GROUND BUS. GENERAL NOTES: 1. THIS BREAKER CONFIGURATION IS PROVIDED TO DEMONSTRATE THE PREFERRED LOCATION. ALL ELECTRICAL REQUIREMENTS, LOAD CALCULATIONS & RELATED CODE REQUIREMENTS ARE TO BE PERFORMED BY A LICENSED ENGINEER TO BE SUBMITTED FOR REVIEW & APPROVAL BY THE DOLLAR GENERAL STORE A & E DEPARTMENT. 2. BREAKERS THAT SERVICE HVAC EQUIPMENT AND MOTOR LOADS COOLERS, FREEZERS, ETC) TO BE HACR. 3. CIRCLED CIRCUIT DENOTES BREAKER LOCKS. 4. ALL BREAKERS 20/1 UNO. 5. ALL WIRE SHALL BE COPPER CONDUCTOR. LTG 3,000VA X 1.25 = 3,750 VA PANEL „B" (54 SPACE) PANEL "R" (42 SPACE) PANEL "Allll (42 SPACE) DUPLEX RECEPTACLE DEDICATED CIRCUIT PREFERRED PANEL LAYOUT. NOT TO SCALE LAYOUT NOTES 1. PROVIDE 3/4" PLYWOOD 16'-0" WIDE X 5'-5" HIGH, FIRE RATED, NO VOIDS, NOT PAINTED UNLESS CODE DICTATES OTHERWISE. 2. REFRIGERATION CONTROL PANEL. PROVIDE POWER AND DATA CONNECTIONS, POWER FROM CIRCUIT R-41. CONTRACTOR TO RUN AN EMPTY 1" CONDUIT WITH PULL STRING FROM THIS PANEL TO THE EMS PANEL. REFRIGERATION CONTRTACTOR TO PULL DATA LINE. 3. EMS, HVAC AND LIGHTING CONTACTOR PANEL PURCHASED AND INSTALLED BY THE ELECTRICAL CONTRACTOR. ALL LIGHTING CIRCUITS SHOWN AS HATCHED IN PANEL B SHALL BE ROUTED THROUGH EMS PANEL AND CONTROLLED. ASTRONOMICAL CLOCK SHALL CONTROL CIRCUITS. DOLLAR GENERAL REFRIGERATION TEAM PROVIDE CONNECTION TO THE RACK. 4. TELEPHONE JACK RJ11 — MOUNT WITHIN 12" OF DMARC. 5. TELEPHONE CONDUIT — ROUTE FROM EXISTING DEMARCATION LOCATION TO THIS LOCATION. �. F� nt xa �"► s� aaaa•"'�a�aw�*s ¢ �r A� . e NT c 0 O (� Lo C7 co :a N Lo N c7 c� LL U Lo O w 0) � N � = a)N rm Q oC00 Oz a)0 (a, O N U) Lu cy)N W ACV >' Q U (a -' O T_ . to U a)— •c 8 M LL o -1� C � s- O j Q1 n G N a a a a a a a a a a a CONTRACT DATE: BUILDING TYPE: PLAN VERSION: SITE NUMBER: STORE NUMBER: 08.01.2018 N/A N/A N/A N/A Ir: 101I_1III Ilm�i&"rm GALL BLVD ZEPHYRHILLS, FL 33541 FINISH PLAN PHASE 2 SCHEDULES, DETAILS & RISER E4 PLOT DATE: QTY. SYMBOL DESCRIPTION CABLE TYPE SUPPLIED BY: INSTALLED BY: NOTES VER. AT AHU TERMINAL STRIP 8C T-STAT CABLE EMS SUPPLIER GENERAL QTY. ONE (1) PER CONTRACTOR HVAC UNIT. 1 0 OUTDOOR AIR TEMP BELDEN 8761 OR EMS SUPPLIER GENERAL QTY. ONE (1) PER MTD. @ 8'-0" A.F.F. EQUIVALENT (22AWG, CONTRACTOR RECEIVING ENTRY. 2C, STRANDED, SHIELDED) VER. SUPPLY TEMP BELDEN 8761 OR EMS SUPPLIER GENERAL QTY. ONE (1) PER ST (501-1121) MTD. IN EQUIVALENT (22AWG, CONTRACTOR HVAC UNIT. SUPPLY DUCT 2C, STRANDED, SHIELDED) VER. TS TEMPERATURE BELDEN 8761 OR EMS SUPPLIER GENERAL QTY. ONE (1) PER SPACE SENSOR EQUIVALENT (22AWG, CONTRACTOR HVAC UNIT ZONE. (809-6590) MTD. @ 2C, STRANDED, 8'-0" A.F.F. SHIELDED) 1 O RJ-11/RJ-45 DATA 24 GA., GENERAL GENERAL QTY. ONE (1) AT JACK, PHONE 4 TWISTED -PAIR, CONTRACTOR CONTRACTOR OFFICE COMBO. CATEGORY -FIVE (CAT 5) DATA CABLE 2 $MOTION SENSOR LEVITON EZ-FIND GENERAL GENERAL QTY. ONE (1) PER M SWITCH. ODS-10-IDW CONTRACTOR CONTRACTOR MEN'S R.R. QTY. ONE (1) PER WOMEN'S R.R. SENSOR PLAN KEYED NOTES ALWAYS INSTALL THESE SENSORS AT 8'-0" A.F.F. THE EXACT MOUNTING LOCATION OF THE HVAC SENSORS "TS" MAY VARY DEPENDING ON THE STORE LAYOUT & DUCT CONFIGURATION. REFER TO SITE SPECIFIC MECHANICAL DRAWINGS FOR HVAC ZONED SENSOR MOUNTING LOCATIONS. IF SENSORS ARE MOUNTED ON EXTERIOR WALLS DUE TO DUCT CONFIGURATION, THEY ARE THEN TO BE INSULATED TO PREVENT AIR INFILTRATION. IF ADDITIONAL HVAC UNITS ARE USED, ADD ADDITIONAL TEMPERATURE SENSORS "TS". PROVIDE LABEL ON FACE OF EACH UNIT. F PHONE LINE #1 - TWO RJ-11 PORTS. ONE (1) LOCATED IN OFFICE W/RJ-45 DATA JACK COMBO AND ONE (1) AT REGISTER. 24 GA. CAT 5, 4-PAIR TWISTED WIRE ONLY. USE BLUE AND BLUE & WHITE WIRES. HOOK TO LINE #1 TERMINAL IN RJ-11 JACK EACH PHONE JACK TO HAVE DEDICATED, SEPARATE HOME RUN TO DMARC. LABEL AS "PHONE" AT THE DESTINATION AND AT DMARC. PHONE COMPANY PROVIDES FINAL HOOK UP TO DMARC ONLY. PHONE LINE #2 - RJ-11 PHONE JACK SUPPLIED AND WIRED BY CONTRACTOR. EMS REFRIGERATION PANEL CX E2 400. PANEL BY OTHERS. F31 CONNECTION FROM THIS PANEL TO HVAC AND LIGHTING PANEL BY OTHERS. ELECTRICAL CONTRACTOR TO RUN AN EMPTY 1-1/2" CONDUIT WITH PULL ROPE BETWEEN THE TWO PANELS. ® ADD ADDITIONAL HVAC UNIT WHEN REQUIRED. REQUIRED NATIONAL ACCOUNT VENDORS CONTACT INFORMATION SUBJECT TO CHANGE COMPANY - PHONE # CONTACTS REQUIRED ITEMS EMERSON CLIMATE TECHNOLOGIES - WEBSITE EMS SUPPLIER NOTE: CUSTOMIZED DOLLAR GENERAL EMS ALL QUESTIONS PERTAINING TO THE EMS PANEL, http://dollargeneralbid.ectsolutions.net PANEL REQUIRES STORE #, CITY, STATE, ZIP CODE & SYSTEM INSTALLATION & SETUP SHOULD BE USER NAME: dollargeneralbid QTY.OF HVAC UNITS FOR THE INSTALL SITE WHEN DIRECTED TO EMERSON'S DOLLAR GENERAL PASSWORD: dollargeneralbid ORDERING. EMS SYSTEMS INSTALLATION GUIDE WITH SUPPORT TEAM AT 770-425-2724. 1 1 PHOTOS IS AVAILABLE ON NATIONAL ACCOUNT WEBSITE. EMS/LOW VOLTAGE PLAN NOT TO SCALE PLAN IS DIAGRAMIC ONLY!! HOLD CONDUIT TIGHT TO.�,it,� STRUCTURE ABOVE AND RUN AS HIGH AS POSSIBLE ALON( PERIMETER WALLS TO RECEIVING AREA. •• ov ,0 rz,s U w H Z z d` Ao co rr w OIL,) N c) C\j L �(j)t0 00 V W W � U 0-) HzI-4� E..� LU f— vx�oc=�o V—'zU`Y' oN � CE N LL �Q a It o JU c1l) CY) co `n J N O w i� � J (D C Oc\j N cC\j O OOcy) IM . a) wO cnc-r� O wap(co �N� U Ill N ca -� N I-♦, 70 Q ;rr O T 6-(oU) N- 0 W Uu- 16009 0 0 0 0 0 0 FRI O J CO n CONTRACT DATE: 08.01.2018 BUILDING TYPE: N/A PLAN VERSION: N/A SITE NUMBER: N/A STORE NUMBER: N/A TENANT FINISH GALL BLVD ZEPHYRHILLS, FL 33541 FINISH PLAN PHASE 2 EMS / LOW VOLTAGE PLAN EMS1 PLOT DATE: