HomeMy WebLinkAbout6512 Gall Blvd (6)_ "•, I _ I I1. I '_ !I 11 npn p: __.I I II I. I 11L_ L I A I I 10 I 9 1 8 I 7 I 6 I 5 I 4 I 3 I 2 1 1 1 A B C D E F G H T100 TITLE SHEET / INDEX / CODE ANALYSIS A000 NOTES S000 NOTES / LOAD CRITERIA A S100 FRAMING PLAN / DETAILS B RADIANT FOOE) STORE IMPACT DAMAGE REPAIR C D I TITLE 2 SHEET INDEX OWNER STRUCTURAL ENGINEER / BUILDING DESIGN FBC 2007REV09 - RESIDENTIAL. EXISTING BUILDING CONNELLY GROUP CONSULTING ENGINEERS FL MECHANICAL 2007REV09 ALTERATION LEVEL - REPAIRS NOTE: CONTRACTOR AND ALL SUB -TRADES FL PLUMBING 2007REV09 (WITHOUT EXCEPTION) SHALL FIELD VERIFY ALL 200 2ND AVE SOUTH FL FIRE PREVENTION CODE 2007REV09 NOTE' DIMENSIONS AND EXISTING CONDITIONS PRIOR #yb5 NEC 2008 �K TO HBE PERFORMED SHALL BE IN CONFORMANCE WITH THE TO ORDERING AND INSTALLATION OF ANY E FBC2007REV09 EXISTING BUILDING CODE RELATING TO REPAIRS OF EXISTING ST PETERSBURG FL 33701 BUILDINGS. INCLUDING THE SECTIONS REFERENCED BELOW. STRUCTURE IS NOT MATERIALS. NOTIFY EOR, IN WRITING. OF ANY PH: 813-232-81448 ADDITIONAL REFERENCES BEING ADDED TO OR ALTERED. DISCREPANCIES PRIOR TO PROCEEDING FAX: 800-b98-1945 ASCE7-05 SECTION 402 EMAIL: INFOOCONNELLYENGINEERING.COM NFPA 101 REPAIRS NFPA I EFFORTS HAVE BEEN MADE TO VERIFY EXISTING CONTACT: CHRISTOPHER R. CONNELLY. PE,CBC 402.1 SCOPE. REPAIRS. AS DEFINED IN CHAPTER 2, INCLUDE THE PATCHING OR CONDITIONS. NO DESTRUCTIVE TESTING HAS NFPA 13 RESTORATION OR REPLACEMENT OF DAMAGED MATERIALS, ELEMENTS. EQUIPMENT BEEN PERFORMED TO VERIFY EXISTING FRAMING. NFPA 10 OR FIXTURES FOR THE PURPOSE OF MAINTAINING SUCH COMPONENTS IN GOOD OR CIVIL ENGINEER MEP SOUND CONDITION WITH RESPECT TO EXISTING LOADS OR PERFORMANCE COMPREHENSIVE FIELD VERIFICATION SHALL BE REQUIREMENTS. REQUIRED BY THE CONTRACTOR DURING / / 402.2 APPLICATION. REPAIRS SHALL COMPLY WITH THE PROVISIONS OF CHAPTER 5. DEMOLITION AND PRIOR TO ORDERING AND - 2- (! ,,4 �l I U D 402.3 RELATED WORK. WORK ON NONDAMAGED COMPONENTS THAT IS NECESSARY INSTALLATION OF ANY MATERIALS. IIILLL/// FOR THE REQUIRED REPAIR OF DAMAGED COMPONENTS SHALL BE CONSIDERED RA- d-1 I'1� _ PART OF THE REPAIR AND SHALL NOT BE SUBJECT TO THE PROVISIONS OF CHAPTER c \ SUL �C.. 6.7.8.9OR10. C►�C� CA'��, 3(dcje_ u)po� CHAPTER 5 REPAIRS mI f 1 (2 �"7?� PURPOSE OF REPAIR r SECTION 501 NOTE: THE FOLLOWING DETAILS AND SPECIFICATIONS SHALL CONSTITUTE A STRUCTURAL GENERAL REPAIR OF THE EXISTING STRUCTURES WALL ELEMENTS CAUSED BY VEHICLE IMPACT. ARCHITECT LANDSCAPE ARCHITECT 501.1 SCOPE. REPAIRS AS DESCRIBED IN SECTION 302 SHALL COMPLY WITH THE DETAILS AND SPECIFICATIONS PRESENTED IN THESE DRAWINGS SHALL INCLUDE IF NECESSARY REPAIR DETAILS AND SPECIFICATIONS TO RETURN THE EXISTING REQUIREMENTS OF THIS CHAPTER. REPAIRS TO HISTORIC BUILDINGS SHALL COMPLY STRUCTURE TOPA STATE AS WAS FOUND PRIOR TO THE DAMAGE. DETAILS AND WITH THIS CHAPTER. EXCEPT AS MODIFIED IN CHAPTER 11. SPECIFICATIONS ARE INTENDED TO REPAIR STRUCTURAL DAMAGE CAUSED BY THE IMPACT AND ARE NOT INTENDED TO RETURN STRUCTURE TO'LIKE NEW' CONDITION, 501.2 PERMITTED MATERIALS. EXCEPT AS OTHERWISE REQUIRED OR PERMITTED BY PORTIONS OF THE STRUCTURE MAY BE REMOVED AND REPLACED WITH ALTERNATIVE MATERIALS. OUR INTENTION IS TO MAINTAIN THE INTEGRITY AND APPEARANCE OF THIS CODE. MATERIALS PERMITTED BY THE APPLICABLE CODE FOR NEW THE ORIGINAL STRUCTURE WITH MINIMAL INTRUSION AND MODIFICATION TO THE CONSTRUCTION SHALL BE USED. LIKE MATERIALS SHALL BE PERMITTED. PROVIDED REMAINING STRUCTURAL FRAMING. NO HAZARD TO LIFE. HEALTH OR PROPERTY IS CREATED' NOTE: MAIN WALL AND ROOF FRAMING AND FOUNDATION UPGRADES ARE EXCLUDED FROM THIS SCOPE OF WORK. WE ARE ASSUMING THE EXISTING STRUCTURE IS EXCEPTION: REPAIRS TO A HISTORIC BUILDING SHALL BE PERMITTED USING CAPABLE OF SUPPORTING THE CURRENT LOADING IMPOSED ON IT. ORIGINAL OR LIKE MATERIALS. MATERIALS SHALL COMPLY WITH SECTIONS 502.1. 502.2 AND 502.3. THE REMOVAL AND REPLACEMENT OF THE DAMAGED FRAMING AND SUBSEQUENT 3 PROJECT TEAM 4 VICINITY MAP �I 5 BUILDING CODES FINISHES FALLS BELOW THE STANDARD FEA/A GUIDELINE AS REFERENCED IN FEMA NORnI 501.3 CONFORMANCE. THE WORK SHALL NOT MAKE THE BUILDING LESS PU13UCATION 55 FOR SUBSTANTIAL IMPROVEMENT AND THEREFORE DOES NOT CONFORMING THAN IT WAS BEFORE THE REPAIR WAS UNDERTAKEN. CONSTITUTE A NECESSARY UPGRADE OF THE EXISTING STRUCTURAL ELEMENTS OF THE BUILDING. ALL REPAIRS SHALL BE MADE IN ACCORDANCE WITH THE GUIDELINES AS SPECIFIED IN THE FLORIDA BUILDING CODE (CURRENT EDITION). WITH REVISIONS 9. ALL MANUFACTURED ARTICLES. MATERIALS AND EQUIPMENT SHALL BE 501.4 FLOOD HAZARD AREAS. IN FLOOD HAZARD AREAS. REPAIRS THAT CONSTITUTE EXISTING BUILDINGS AND ALL APPLICABLE LOCAL CODES. THE ENGINEER SHALL BE 17. THE CONTRACTOR WARRANTS TO THE OWNER AND THE ARCHITECTAOR THAT SUBSTANTIAL IMPROVEMENT SHALL REQUIRE THAT THE BUILDING COMPLY WITH iMMEDiATELY NOTIFIED. IN WRITING. OF ANY ITEMS ANY ITEMS FOUND TO BE DAMAGED I. G.C. SHALL BECOME FAMILIAR WITH ALL OWNER'S REQUIREMENTS APPLIED. INSTALLED. CONNECTED. ERECTED. USED. CLEANED. AND ALL MATERIALS AND EQUIPMENT FURNISHED UNDER THIS CONTRACT 23. DISSIMILAR METALS PROTECTION PRIOR TO BIDDING AND SHALL BE RESPONSIBLE FOR COMPLIANCE WITH CONDITIONED IN ACCORDANCE WITH THE MANUFACTURERS' WRITTEN OR IMPROPERLY REMOVED DURING THE BUILDING MODIFICATION. ALL TEMPORARY WILL BE NEW UNLESS OTHERWISE SPECIFIED. AND THAT ALL WORK CONTACTS NOT INVOLVING MAGNESIUM. SECTION I6I2 OF THE FLORIDA BUILDING CODE. BUILDING. SUPPORnNG ELEMENTS SHALL BE EQUAL OR GREATER IN STRUCTURAL CAPACITY TO THOSE REQUIREMENTS. SPECIFICATIONS OR INSTRUCTIONS UNLESS HEREINAFTER SPECIFIED WILL BE GOOD QUALITY FREE FROM FAULTS AND DEFECTS AND IN ALL DISSIMILAR JOINTS NOT INVOLVING MAGNESIUM ARE PROTECTED BY THE APPLICATION OF A THE ITEM BEING REMOVED. 501.4.1 STRUCTURE SEAWARD OF A COASTAL CONSTRUCTION LINE. STRUCTURES 2. FIELD VERIFY ALL DIMENSIONS PRIOR TO CONSTRUCTION. NOTIFY TO THE CONTRARY. CONFORMANCE WITH THE CONSTRUCTION DOCUMENTS. ALL WORK NOT SO MINIMUM OF TWO COATS OF ZINC CHROMATE PRIMER IN ADDITION TO NORMAL PRIMER LOCATED SEAWARD OF THE COASTAL CONSTRUCTION LINE SHALL BE DESIGNED TO CONFORMING TO THESE STANDARDS MAY BE CONSIDERED DEFECTIVE. IT REQUIREMENTS PRIMER IS APPLIED BY BRUSH OR SPRAY AND ALLOWED TO AIR-DRY 6 HOURS RESIST THE PREDICTED FORCES OF A 100 YEAR STORM EVENT IN ACCORDANCE WITH ARCHITECT/EOR OF ANY DISCREPANCIES. 10. THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE WORK. USING HIS IS UNDERSTOOD THAT NO INFERIOR OR NOW CONFORMING WORK OR 3. ITEMS NOT INDICATED IN THESE DOCUMENTS THAT CAN BE BEST SKILL AND ATTENTION. HE SHALL BE SOLELY RESPONSIBLE FOR MATERIALS WILL BE ACCEPTED WHETHER DISCOVERED AT THE TIME BETWEEN COATS. SECTION 3109 OF THE FLORIDA BUILDING CODE. BUILDING. ALL CONSTRUCTION AND/OR INSTALLATION MEANS. METHODS. THEY ARE INCORPORATED IN THE WORK OR AT ANY TIME BEFORE OR LEGITIMATELY AND REASONABLY INFERRED TO COMPLETE THE WORK AT TECHNIQUES. SEQUENCES. AND PROCEDURES AND FOR COORDINATING AFTER THE FINAL ACCEPTANCE. IF REQUIRED BY THE ARCHITECT/EOR. THE 501.4.2 FLOODPLAIN CONSTRUCTION. THIS CODE SPECIFICALLY DEFERS TO THE G HAND SHALL BE FURNISHED BY THE CONTRACTOR AS THOUGHT IT WERE CONTACTS INVOLVING MAGNESIUM' ALL PORTIONS OF THE WORK UNDER THE CONTRACT. CONTRACTOR SHALL FURNISH SATISFACTORY EVIDENCE AS TO THE AUTHORITY GRANTED TO LOCAL GOVERNMENT BY TITLE 44 CFR. SECTIONS 59 AND DETAILED HEREIN. KIND AND QUALITY OF MATERIALS AND EQUIPMENT. TO PREVENT CORROSION BETWEEN DISSIMILAR -METAL JOINTS IN WHICH MAGNESIUM ALLOYS IS 60. THIS CODE IS NOT INTENDED TO SUPPLANT OR SUPERCEDE LOCAL ORDINANCES 4. DRAWINGS SHALL BE DISTRIBUTED TO SUBCONTRACTORS IN COMPLETE II. DIMENSIONS TAKE PRECEDENCE OVER SCALE ON CONSTRUCTION INVOLVED, EACH SURFACE SHALL BE INSULATED AS FOLLOWS : ADOPTED PURSUANT TO THAT AUTHORITY, NOR ARE LOCAL FLOODPLAIN SETS AS INDICATED BY THE SHEET INDEX. G.C. IS RESPONSIBLE FOR DOCUMENTS. 18. THE WARRANTIES AND GUARANTIES REQUIRED BY THE CONSTRICTION . AT LEAST TWO COATS OF ZINC CHROMATE ARE APPLIED TO EACH SURFACE. NEXT.ADD A LAYER OF MANAGEMENT ORDINANCES TO BE DEEMED AMENDMENTS TO THE CODE. ENSURING SUBCONTRACTORS BID ON ALL ITEMS ASSOCIATED WITH DOCUMENTS SHALL BE IN ADDITION TO AND NOT IN LIMITATION OF PRESSURE -SENSITIVE VINYL TAPE 0.003-INCH THICK APPLIED SMOOTHLY AND FIRMLY ENOUGH TO THEIR RESPECTIVE TRADES. i2. ALL WORK SHALL BE EXECUTED IN A NEAT AND WORKMANLIKE MANNER ACCEPTABLE TO OWNER. BY THE CONSTRUCTION DOCUMENTS. PREVENT AIR BUBBLES AND WRINKLES. TO AVOID CREEP -BACK, DO NOT STRETCH THE TAPE DANGEROUS. NO WORK SHALL BE REQUIRED EXCEPT AS NECESSARY TO CORRECT DURING APPLICATION. WHEN THE THICKNESS OF THE TAPE INTERFERES WITH THE ASSEMBLY OF IDENTIFIED DANGEROUS CONDITIONS. 5. THE CONTRACTOR WILL INSPECT THE PREMISES IMMEDIATELY TO CHECK 13. WHEN WORK NOT SPECIFICALLY CALLED OUT IS REQUIRED TO COMPLETE 19. CONTRACTOR SHALL PROVIDE PROPER SHORING AND DISCONNECTION OF PARTS. WHERE RELATIVE MOTION EXISTS BETWEEN PARTS. OR WHEN SERVICE TEMPERATURES SECTION 502 CONTRAC TOR FIND EXISTING WORKING CONDITIONS. SHOULD C THE PROJECT. IT SHALL BE PROVIDED AND BE OF THE BEST ALL UTILITIES BEFORE ANY DEMOLITION. CONDITIONS WHICH HE BELIEVES WOULD IMPEDE HIS WORK. THEN SUCH MATERIALS AND WORKMANSHIP. ABOVE 250 F. ARE ANTICIPATED. THE USE OF TAPE IS ELIMINATED AND EXTRA COATS (MINIMUM OF BUILDING ELEMENTS AND MATERIALS CONDITIONS MUST BE REPORTED IMMEDIATELY TO THE ARCHITECT/EOR. 20. CONTRACTOR SHALL PATCH, REPAIR, REPLACE, AND FINISH ANY 502.1 HAZARDOUS MATERIALS. HAZARDOUS MATERIALS THAT ARE NO LONGER FAILURE TO SO ADVISE WILL CONSTITUTE NOTICE THAT CONTRACTOR 14. CONTRACTOR SHALL GUARANTEE ALL WORKMANSHIP AND MATERIALS FOR FLOOR. WALL. OR CEILING TO MATCH ADJACENT SURFACES DUE TO ANY THREE) OF PRIMER ARE APPLIED - IS FULLY SATISFIED WITH THE EXISTING CONDITIONS AND THATHE A PERIOD OF TWO YEARS FROM THE DATE OF SUBSTANTIAL COMPLETION DEMOLITION. PERMITTED. SUCH AS ASBESTOS AND LEAD BASED PAINT. SHALL NOT BE USED. INTENDS TO PERFORM HIS OBLIGATIONS WITH NO ALLOWANCE EITHER (IN WRITING). 24, AT THE END OF EACH DAYS WORK. ALL UNUSED NAILS AND MATERIAL USED FOR THAT DAY SHALL BE IN TIME OR MONEY FOR ANY IMPEDIMENTS TO HIS WORK. 21. FIRE SPRINKLER APPROVALS ARE NOT INCLUDED UNDER THIS COLLECTED ANDSTORED OR DISPOSED OF AS REQUIRED 502.2 GLAZING IN HAZARDOUS LOCATIONS. REPLACEMENT GLAZING IN HAZARDOUS 6. CONTRACTOR SHALL NOTIFY ARCHITECT/EOR OF ANY DISCREPANCIES AND 15. UNLESS OTHERWISE SPECIFICALLY NOTED. THE CONTRACTOR SHALL PERMIT. LOCATIONS SHALL COMPLY WITH THE SAFETY GLAZING REQUIREMENTS OF THE FOLLOW UP IN WRITING WITHIN TWO WORKING DAYS. PROVIDE AND PAY FOR ALL LABOR, MATERIALS, EQUIPMENT. TOOLS. FLORIDA BUILDING CODE. BUILDING AS APPLICABLE. CONSTRUCTION EQUIPMENT AND MACHINERY, TRANSPORTATION. AND 25. PROJECT SUPERVISOR SHALL INSPECT AND CERTIFY THE CORRECT INSTALLATION OF ALL OTHER FACILITIES AND SERVICES NECESSARY FOR PROPER EXECUTION THRU-WALL SCUPPERS AND SHALL ISSUE SAID CERTIFICATION IN WRITING. AND FOR THE RECORD. TO EXCEPTION: GLASS BLOCK WALLS. LOUVERED WINDOWS. AND JALOUSIES REPAIRED 7. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS IN THE FIELD. IF DIMENSIONAL ERROR OCCURS OR CONDITION NOT COVERED AND COMPLETION OF THE PROJECT. GENERAL CONTRACTOR OF RECORD. WHERE DISCREPANCIES EXISTING IN THE INSTALLATION, THE FOR WITH LIKE MATERIALS. IN THE DRAWINGS IS ENCOUNTERED. CONTRACTOR SHALL NOTIFY THE I6. THE CONTRACTOR SHALL PAY ALL FEES FOR PERMITS, ETC.. SHALL BE NOTIFIED IMMEDIATELY IN WRITING. ARCHITECT/EOR BEFORE COMMENCING THAT PORTION OF THE WORK. NECESSARY FOR PROPER COMPLETION OF THE WORK UNLESS OTHERWISE 22. EXTERIOR SIGNAGE IS NOT PART OF THIS PROJECT. 02.3 REPLACEMENT. FOR REPAIRS IN AN HISTORIC BUILDING. REPLACEMENT OR INFORMED. 26. CONTRACTOR SHALL MAINTAIN A VISUAL RECORD ALL MATERIAL DEMOLITION AND INSTALLATIONS, PARTIAL REPLACEMENT of EXISTING OR MISSING FEATURES THAT MATCH THE 8. ALL WORK SHALL COMPLY WITH ALL APPLICABLE CODES AND INCLUDING BEFORE AND AFTER PHOTOS. ALL PHOTOS SHALL BE TAKEN BY USE OF DIGITAL CAMERA ORIGINAL IN CONFIGURATION. HEIGHT. SIZE AND ORIGINAL METHODS OF H ORDINANCES. CONSTRUCTION SHALL BE PERMITTED. AND SHALL BE MADE AVAILABLE TO OWNER AND FOR AS REQUIRED. A MINIMUM OF 10 PHOTOS MUST BE TAKEN PER SPECIFIC INSTALLATION, EXCEPTION: GLAZING IN HAZARDOUS LOCATIONS SHALL COMPLY WITH SECTION 502.2. 6 GENERAL NOTES 7 CODE ANALYSIS 1 10 I 9 I 8 1 7 I 6 I 5 I 4 I 3 I 2 1 1 RADIANTZH IMPACT C1312-016 CONNELLY GROUP py CONSULTING ENGINEERS 200 2nd Ave South - #465 - St Petersburg, FL 33701 CD info®connellyengineering.com (TJ813.232.8448 (F)BOO. 698. 1945 www.connellyenginee ring.- Lij FBC 2007REV09, CHAPTER I 105.4.1 PERMIT INTENT Ili 1 LL BE CONSTRUCTED TO BE A LICENSE TO PROCEED PROJECT DATA C WITH THE WORK AND NOT AS AUTHORITY TO VIOLATE. CANCEL ALTER OR SET ASIDE ANY OF THE PROJISIONS OF THE TECHNICAL CODES. NOR SHALL ISSUANCE OF A PERMIT DESIGNER b..S PREVENT THE BUILDIND OFFICIAL FROM THEREAFTER REQU1RIW ACORRECTION OF ERRORS IN PIANS, CONSTRUCTION OR VIOLATIONS OF THIS CODE. EVERY PERMIT ISSUED SHALL BECOME INVALID CRC UNLESS THE WORK AUTHORIZED BY SUCH PERMIT IS COMMENCED WITHIN SIX MONTHS AFTER ITS ISSUANCE. OR IF THE WORK AUTHORIZED BY SUCH PERMIT IS SUSPENDED OR ABANDONED FORA PERM DRAWN BY GIT OF SIX MONTHS AFTER THE TIME THE WORK IS COMMENCED JJC CHECKED CRC WEHEREBYCERTIFYTHAT THESE PLANS AND SPECIFICATIONS COMPLY WITH THE REQUIREMENTS OF THE APPLICABLE BUILDING CODES SPECIFIED ON THE TITLE SHEET LU w�. NORTH v� vv w t 2- 3- ITY OF ZEPHYRHILL'S LANE EXAMINEF4'�C J ALL WORK SHALL COMPLY WITH ALL PREVAILING CODES, FLORIDA BUILDIN CODE, NATIONAL ELECTRIC CODE AND 0 CV L0 cM M � LL W > w D 13. j V Z w m J J Q J J = o a� Q Q Q N _ .o N DRAWING SETS PERMIT 01.25.12 O PROFESSIONAL SEAL DATE SEALED: Z5-JAN-1 2 z g....,• � s ti �. fir_ I �� •. �% •' �� I • F g :s Ll AD • STAY CH PE-F CODE Dd�,� F.,., I TITLE SHEET T100 10 I 9 I 8 I 7 I 6 I 5 I 4 3 I 2 1 0 i C C E F ALL MATERIALS. WORKMANSHIP, DESIGN AND CONSTRUCTION SHALL CONFORM TO THE DRAWINGS, SPECIFICATIONS AND THE FLORIDA BUILDING CODE SECTION 1609. CURRENT EDITION WITH REVISIONS. DESIGN DEAD LOAD CRITERIA ROOF DEAD LOAD 15PSF FLOOR DEAD LOAD 25PSF STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH ARCHITECTURAL DRAWINGS FOR BIDDING AND CONSTRUCTION CONTRACTOR SHALL VERIFY DIMENSIONS AND CONDITIONS FOR COMPATIBILITY AND SHALL NOTIFY ARCHITECT OF ANY DISCREPANCIES PRIOR TO CONSTRUCTION CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS PRIOR TO COMMENCING ANY WORK AND DETERMINE THE LOCATION OF ALL ADJACENT UNDERGROUND UTILITIES PRIOR TO COMMENCING EXCAVATION. AND NOTIFY ARCHITECT OF DISCREPANCIES AND CONFLICTS, CONTRACTOR SHALL PROVIDE TEMPORARY BRACING FOR THE STRUCTURE AND STRUCTURAL COMPONENTS UNTIL ALL FINAL CONNECTIONS HAVE BEEN COMPLETED IN ACCORDANCE WITH THE PLANS. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SAFETY PRECAUTIONS AND THE METHODS. TECHNIQUES, SEQUENCES OR PROCEDURES REQUIRED TO DO THE WORK. SHOP DRAWINGS FOR STRUCTURAL STEEL AND CONNECTOR PLATE WOOD ROOF TRUSSES AND TJI JOIST SHALL BE SUBMITTED TO THE ARCHITECT AND/OR STRUCTURAL ENGINEER SIGNED AND SEALED BY REGISTERED ENGINEER AND/OR ARCHITECT REGISTERED IN THE STATE OF FLORIDA FOR REVIEW PRIOR TO FABRICATION OF APPROVED OF THESE ITEMS. ALL SHOP DRAWINGS SHALL ALSO BE SUBMITTED TO THE BUILDING DEPARTMENT. SHOP DRAWINGS REVIEW: DIMENSIONS AND QUANTITIES ARE NOT REVIEWED BY THE ENGINEER OF RECORD. THEREFORE MUST BE VERIFIED BY THE CONTRACTOR. CONTRACTOR SHALL REVIEW AND STAMP DRAWINGS PRIOR TO REVIEW BY ENGINEER OF RECORD. SUBMITTALS SHALL INCLUDED A REPRODUCIBLE AND ONE COPY. REPRODUCIBLE WILL BE MARKED AND RETURNED. SHOP DRAWINGS SUBMITTALS PROCESSED BY THE ENGINEER ARE NOT CHANGE ORDERS. THE PURPOSE OF SUBMITTAL BY THE CONTRACTOR IS TO DEMONSTRATE UNDERSTANDING OF THE DESIGN CONCEPT, THE MATERIALS INTENDED TO BE FURNISHED AND INSTALLED. AND TO DETAIL THE INTENDED FABRICATION AND INSTALLATION METHODS. IF DEVIATIONS. DISCREPANCIES. OR CONFLICTS BETWEEN SHOP DRAWING SUBMITTAL AND THE CONTRACT DRAWINGS ARE DISCOVERED EITHER PRIOR TO. OR AFTER SHOP DRAWING SUBMITTAL ARE PROCESSED BY THE ENGINEER. THE DESIGN DRAWINGS AND SPECIFICATIONS SHALL CONTROL AND BE FOLLOWED. WOOD DIMENSIONED LUMBER SHALL BE DRESSED S41S AND SHALL BEAR THE GRADE STAMP OF THE SUPPLIER'S ASSOCIATION. ALL LUMBER SHALL BE SOUND AND FREE FROM WARP. ALL LUMBER SHALL BE SOUTHERN PINE GRADE NO. 2 OR BETTER WITH THE FOLLOWING MINIMUM PROPERTIES (U.O.N.): FB- 1.200PSI FV- 150PSI FC- 975 PSI E= 1.600,000 PSI II% MAXIMUM MOISTURE CONTENT ALL WOOD IN CONTACT WITH CONCRETE OR MASONRY SHALL BE PRESSURE TREATED. PRESSURE TREATED LUMBER SHALL BE IMPREGNATED WITH A CCA SALT TREATMENT IN ACCORDANCE WITH F.S. TT-W-571 AND BEAR THE AMERICAN WOOD PRESERVES INSTITUTE QUALITY MARK LP-2. WOOD CONTINUED PLYWOOD SHEATHING SHALL BE DFPA CD WITH EXTERIOR GLUE. ALL ROOF SHEATHING SHALL BE INSTALLED WITH PLYCLIPS BETWEEN TRUSSES. INSTALL BRIDGING IN ALL FLOOR AND ROOF JOISTS W 8'- 0" O.C. MAXIMUM. INSTALL BLOCKING IN ALL WALL STUDS AT PLYWOOD EDGES. ALL NAILING AND BOLTING SHALL COMPLY WITH AMERICAN INSTITUTE OF TIMBER CONSTRUCTION REQUIREMENTS. PROVIDE A SINGLE PLATE AT THE BOTTOM AND A DOUBLE PLATE AT THE TOP OF ALL BEARING STUD WALLS. STUDS SHALL BE DOUBLED AT ALL ANGLES AND AROUND ALL OPENINGS. STUDS SHALL BE TRIPLED AT ALL CORNERS. INSTALL ALL CONNECTORS AND TIES PER MANUFACTURER TO THEIR HIGHEST CAPACITY. IF WOOD SHOWS EVIDENCE OF CRACKING FROM FASTENERS. PRE DRILL FOR FASTENERS OR USE SELF -TAPPING FASTENERS PRE-ENGINEERED WOOD TRUSSES CODES AND STANDARDS: A. NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION LATEST EDITION. B. DESIGN SPECIFICATIONS FOR METAL PLATE CONNECTION WOOD TRUSSES. TPI-85. PUBLISHED BY THE TRUSS PLATE INSTITUTE. C. HIB - 01, PUBLISHED BY THE TRUSS PLATE INSTITUTE. D. ALL REQUIREMENTS OF TRUSS PLATE INSTITUTE. MAXIMUM DEFLECTION: LIVE LOAD L/360 DEAD LOAD L/240 DESIGN WOOD TRUSSES FOR THE LOADS SHALL MEET WIND LOADS SHOWN ON THE DRAWINGS TRUSS ERECTOR IS RESPONSIBLE FOR THE TEMPORARY BRACING OF THE TRUSSES. TRUSS MANUFACTURER SHALL CLEARLY SHOW THE SIZE AND LOCATION OF ALL REQUIRED TOP AND BOTTOM CHORD BRACING TRUSS MANUFACTURER SHALL PROVIDE ALL CONNECTIONS. HANGERS. HEADER. BEAMS. ETC. IN ORDER TO COMPLETE THE FLOOR FRAMING AS SHOWN ON DRAWINGS. SUBMITTAL: DETAILED SHOP DRAWINGS SHOWING LAYOUT. BRIDGING. CONNECTION DETAILS. AND ALL ACCESSORY MATERIALS TO TO SAFELY COMPLETE THE FLOOR SYSTEM. PROVIDE CALCULATIONS AND DRAWINGS SIGNED AND SEALED BY A LICENSED FLORIDA ENGINEER REGISTERED IN THE STATE OF FLORIDA. PREFABRICATED CONNECTOR PLATE WOOD ROOF TRUSSES SHALL BE DESIGNED BY THE MANUFACTURER IN ACCORDANCE WITH THE DESIGN SPECIFICATION FOR METAL PLATE CONNECTED WOOD TRUSSES. TPI-78. BY THE TRUSS PLATE INSTITUTE FOR THE SPANS AND CONDITIONS SHOWN ON THE PLANS. WOOD TRUSSES SHALL UTILIZE APPROVED CONNECTOR PLATES. SUBMIT SHOP DRAWINGS TO THE ARCHITECT AND/OR STRUCTURAL ENGINEER FOR REVIEW PRIOR TO FABRICATION. SUBMITTED DOCUMENTS SHALL BEAR THE STAMP AND SIGNATURE OF A REGISTERED PROFESSIONAL ENGINEER REGISTERED IN THE STATE OF FLORIDA. PROVIDE FOR SHAPES. BEARING POINTS. INTERSECTIONS. HIPS. VALLEYS. ETC. SHOWN ON THE DRAWINGS. EXACT COMPOSITION OF SPECIAL HIP. VALLEY. AND INTERSECTION AREAS (USE OF GIRDER TRUSSES, JACK TRUSSES. STEP-DOWN TRUSSES. ETC.) SHALL BE DETERMINED BY THE MANUFACTURER UNLESS SPECIFICALLY INDICATED ON PLANS. PROVIDE ALL TRUSS TO TRUSS AND TRUSS TO GIRDER TRUSS CONNECTION DETAILS AND REQUIRED CONNECTION MATERIALS. PROVIDE FOR ALL TEMPORARY AND PERMANENT TRUSS BRACING AND BRIDGING. THE BUCK -(THE WOOD BETWEEN THE DOOR JAMB AND THE WALL) IS THINNER THAN 1-1/2 INCHES. THE JAMB HAS TO BE ANCHORED THROUGH THE BUCK AND INTO THE WALL IF THE BUCK IS 1-1/2 INCHES OR THICKER. THE BUCK MUST BE SECURED IN A WAY THAT IT BECOMES PART OF THE HOME'S SUPERSTRUCTURE. FBC R613.6 THE MULLIONS -(THE STRIPS BETWEEN A SERIES OF WINDOWS) MUST BE CERTIFIED TO WITHSTAND THE AREA'S HIGH WINDS. MULLIONS AND ADJACENT DOOR ASSEMBLIES ARE REQUIRED TO BE TESTED OR ENGINEERED TO TRANSFER 1.5 TIMES THE DESIGNED LOADS TO THE ROUGH OPENING SUBSTRATE. FBC R613.7 GLUE LAMINATED MEMBERS SHALL BE FABRICATED IN CONFORMANCE WITH SBC STANDARDS. EACH MEMBER SHALL BEAR AN AITC IDENTIFICATION MARK AND SHALL BE ACCOMPANIED BY AN AITC CERTIFICATE OF CONFORMANCE. ALL SIMPLE SPANS BEAMS SHALL BE DOUGLAS FIR COMBINATIONS 24F-V4. FB-2.400 PSI. FV-165 PSI. LAMINATED VENEER LUMBER (LVL) SHALL BE MANUFACTURED UNDER A PROCESS APPROVED BY THE NATIONAL RESEARCH BOARD. EACH PIECE SHALL BEAR A STAMP OR STAMPS NOTING THE NAME AND PLANT NUMBER OF THE MANUFACTURER. THE GRADE. THE NATIONAL RESEARCH BOARD NUMBER. AND THE QUALITY CONTROL AGENCY. ALL LAMINATED VENEER LUMBER SHALL BE MANUFACTURED IN ACCORDANCE WITH NER-126 USING DOUGLAS FIR VENEER GLUED WITH A WATERPROOF ADHESIVE MEETING THE REQUIREMENTS OF ASTM D2559 WITH ALL GRAIN PARALLEL WITH THE LENGTH OF THE MEMBER. FB-2,600 PSI. E-1-800.000 PSI FV- 285 PSI (FOR 1.8E MEMBERS) FB-2.985 PSI, E-2.000.000 PSI. FV-285 PSI (FOR 1-3/4' WIDE 2.0E MEMBERS) FB-2.485 PSI E-2.000.000 PSI. FV-285 PSI (FOR 3 I/2" WIDE 2.0E MEMBERS) ICONSTRUCTION NOTES SCALE: -- I 10 I 9 DESIGN SHOWN ON PLANS IS BASED ON LUMBER MANUFACTURED BY THE TRUS-JOIST CORPORATION. ALTERNATIVE MANUFACTURERS MAY BE USED SUBJECT TO REVIEW AND APPROVAL BY THE ARCHITECT AND/OR STRUCTURAL ENGINEER ALTERNATE JOIST HANGERS AND OTHER HARDWARE MAY BE SUBSTITUTED FOR ITEMS SHOWN PROVIDED THEY HAVE I.C.B.O. APPROVAL FOR EQUAL OR GREATER LOAD CAPACITIES. ALL JOIST HANGERS AND OTHER HARDWARE SHALL BE COMPATIBLE IN SIZE WITH MEMBERS PROVIDED. PARALLEL STRAND LUMBER (PSL) SHALL BE MANUFACTURED UNDER A PROCESS APPROVED BY THE NATIONAL RESEARCH BOARD. EACH PIECE SHALL BEAR A STAMP OR STAMPS NOTING THE NAME AND PLANT NUMBER OF THE MANUFACTURER. THE GRADE, THE NATIONAL RESEARCH BOARD NUMBER. AND THE QUALITY CONTROL AGENCY. ALL LAMINATED VENEER LUMBER SHALL BE MANUFACTURED IN ACCORDANCE WITH NER-126 USING DOUGLAS FIR VENEER GLUED WITH A WATERPROOF ADHESIVE MEETING THE REQUIREMENTS OF ASTM D2559 WITH ALL GRAIN PARALLEL WITH THE LENGTH OF THE MEMBER: FB- 2.900 PSI, E=2,000.000 PSI. FV-290 PSI (FOR 2.0E MEMBERS) FB- 3.100 PSI, E-2.100.000 PSI, FV-290 PSI (FOR 2,IE MEMBERS) DESIGN SHOWN ON PLANS IS BASED ON LUMBER MANUFACTURED BY THE TRUS-JOIST CORPORATION. ALTERNATE MANUFACTURERS MAY BE USED SUBJECT TO REVIEW AND APPROVAL BY THE ARCHITECT AND/OR STRUCTURAL ENGINEER. ALTERNATE JOIST HANGERS AND OTHER HARDWARE MAY BE SUBSTITUTED FOR ITEMS SHOWN PROVIDED THEY HAVE I.C.B.O. APPROVAL FOR EQUAL OR GREATER LOAD CAPACITIES. ALL JOIST HANGERS AND OTHER HARDWARE SHALL BE COMPATIBLE IN SIZE WITH MEMBERS PROVIDED. WOOD FRAMING NOTES: THE FOLLOWING APPLY UNLESS OTHERWISE NOTED ON THE PLANS: EXTERIOR PLYWOOD SHEATHING SHALL BE GRADE C-D. EXTERIOR GLUE OR STRUCTURAL II. EXTERIOR GLUE. TIMBER CONNECTORS INDICATED BY LETTERS AND NUMBERS SHALL BE STRONG TIE BY SIMPSON COMPANY, AS SPECIFIED IN THEIR CATALOG. EQUIVALENT DEVICES BY OTHER MANUFACTURERS MAY BE SUBSTITUTED. PROVIDED THEY HAVE I.C.B.O. APPROVAL FOR EQUAL OR GREATER LOAD CAPACITIES. PROVIDE NUMBER AND SIZE OF FASTENERS AS SPECIFIED BY MANUFACTURER. CONNECTORS SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. BOLTS IN WOOD MEMBERS SHALL CONFORM TO ASTM A307. PROVIDE WASHERS UNDER THE HEADS AND NUTS OF ALL BOLTS AND LAG SCREWS BEARING ON WOOD. UNLESS NOTED OTHERWISE, ALL NAILS SHALL BE COMMON. ALL SHIMS SHALL BE SEASONED AND DRIED AND OF THE SAME GRADE (MINIMUM) AS THE MEMBERS CONNECTED. ALL JOISTS SHALL BE CONNECTED TO FLUSH BEAMS WITH JOIST HANGERS. UNLESS OTHERWISE NOTED. ALL WOOD FRAMING DETAILS NOT SHOWN OTHERWISE SHALL BE CONSTRUCTED TO THE MINIMUM STANDARDS OF THE 2004 FLORIDA BUILDING CODE. MINIMUM NAILING. UNLESS OTHERWISE NOTED. SHALL BE COMMON. COORDINATE THE SIZE AND LOCATION OF ALL OPENINGS WITH MECHANICAL AND ARCHITECTURAL DRAWINGS. PROVIDE WASHERS UNDER THE HEADS AND NUTS OF ALL BOLTS AND LAG SCREWS BEARING ON WOOD. WOOD FRAMING NOTES CONTINUED WALL FRAMING: ALL STUDS WALLS SHOWN AND NOT OTHERWISE NOTED SHALL BE 2X4 STUDS AT 16"O.C. TWO STUDS MINIMUM SHALL BE PROVIDED AT THE END OF ALL WALLS AND AT EACH SIDE OF ALL OPENINGS. SOLID BLOCKING FOR WOOD COLUMNS SHALL BE PROVIDED THROUGH FLOORS TO SUPPORTS BELOW. PROVIDE SOLID BLOCKING BETWEEN STUDS AT MID -HEIGHT OF ALL STUD WALLS OVER 8 FT IN HEIGHT. ALL STUD WALLS SHALL HAVE THEIR LOWER WOOD PLATES ATTACHED TO WOOD FRAMING BELOW WITH 16D NAILS AT 12"O.C. STAGGERED OR BOLTED TO CONCRETE WITH 1/4"X 3-1/4" TAP CONS AT 16"O.C. UNLESS OTHERWISE NOTED. MEMBERS OF BUILT-UP POSTS SHALL BE NAILED TO EACH OTHER WITH 16D AT 12"O.C. STAGGERED. REFER TO THE PLANS AND SHEAR WALL SCHEDULE FOR REQUIRED SHEATHING AND NAILING. WHEN NOT OTHERWISE NOTED. PROVIDE GYPSUM WALLBOARD ON INTERIOR SURFACES NAILED TO AL STUDS, TOP AND BOTTOM PLATES. AND BLOCKING WITH NAILS AT TO.C. USE 5D COOLER NAILS FOR I/2" GWB AND 6D COOLER NAILS FOR 5/8" GWB. PROVIDE 1/2" PLYWOOD SHEATHING ON EXTERIOR SURFACES NAILED AT ALL PANEL EDGES (BLOCK UNSUPPORTED EDGES). TOP AND BOTTOM PLATES WITH 8D AT 4-O.C.. AND TO ALL INTERMEDIATE STUDS AND BLOCKING WITH 8D AT 8'O.C. ALLOW 1/8" SPACING AT ALL PANEL EDGES AND ENDS. FLOOR AND ROOF FRAMING: PROVIDE DOUBLE JOIST UNDER AND AROUND ALL OPENINGS IN FLOORS OR ROOFS UNLESS NOTED OTHERWISE. PROVIDE BRIDGING A 8 FT O.C. AND SOLID BLOCKING AT ALL BEARING POINTS. TOENAIL JOIST TO SUPPORTS WITH TWO 16D NAILS. ATTACH TIMBER JOIST TO FLUSH HEADERS OR BEAMS WITH SIMPSON METAL JOIST HANGERS IN ACCORDANCE WITH SCHEDULE. NAIL ALL MULTI -JOIST BEAMS TOGETHER WITH 16D AT 12"O.C. STAGGERED. UNLESS NOTED OTHERWISE ON THE PLANS. APA RATED ROOF AND FLOOR SHEATHING SHALL BE PLACED WITH STRENGTH AXIS PERPENDICULAR TO SUPPORTS AND NAILED WITH 8D NAILS AT 6"O.C. TO FRAMED PANEL EDGES AND OVER STUD WALLS AS SHOWN ON PLANS AND AT 12"O.C. TO INTERMEDIATE SUPPORTS. PROVIDE APPROVED PLYWOOD EDGE CLIPS CENTERED BETWEEN JOIST/TRUSSES AT UNBLOCKED ROOF SHEATHING EDGES. ALL FLOOR SHEATHING EDGES SHALL HAVE APPROVED TONGUE -AND -GROOVE JOINTS OR SHALL BE SUPPORTED WITH SOUD BLOCKING. ALLOW 1/8" SPACING AT ALL PANEL EDGES AND ENDS OF ALL ROOF AND FLOOR SHEATHING. TOENAIL BLOCKING TO SUPPORTS WITH 2-16D AT EACH END OR AT 12"O.C. UNLESS OTHERWISE NOTED. THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING ALL EXISTING CONDITIONS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING ARCHITECTURAL. STRUCTURAL. MECHANICAL. AND ELECTRICAL DETAILS AND DIMENSIONS. ANY DISCREPANCIES BETWEEN SUCH DETAILS AND DIMENSIONS SHALL BE REPORTED TO THE FOR PRIOR TO PROCEEDING WITH THE WORK. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ERECTION PROCEDURE AND SEQUENCE TO INSURE THE INTEGRITY OF THE BUILDING AND ITS COMPONENT PARTS DURING CONSTRUCTION. THESE PLANS HAVE BEEN PREPARED PER REGULATIONS OF THE FLORIDA BUILDING CODE. THE WORK OF ALL CONTRACTORS SHALL COMPLY WITH THE REQUIREMENTS SET FORTH IN THE AFOREMENTIONED CODE. NO DEVIATIONS FROM THE WORK SHOWN OR REASONABLY IMPLIED SHALL BE UNDERTAKEN WITHOUT THE EOR'S WRITTEN CONSENT - A COPY OF WHICH WILL BE FILLED WITH THE CONSTRUCTION OFFICIAL. ANY CHANGES TO OR DEVIATIONS FROM THESE DRAWINGS SHALL NOT BE MADE WITHOUT WRITTEN CONSENT FROM THE EOR. THESE DRAWINGS ARE THE PROPERTY OF THE FOR AND SHALL NOT BE USED WITHOUT HIS CONSENT. DRAWINGS SHALL NOT BE USED FOR ISSUE OF BUILDING PERMIT UNLESS SIGNED AND SEALED BY THE EOR. THE OWNER AND THE CONTRACTOR SHALL HOLD HARMLESS THE FOR FROM AND AGAINST ALL LIABILITY CLAIMS, DAMAGES. LOSSES AND EXPENSES INCLUDING LEGAL FEES ARISING OUT OF OR RESULTING FROM ERRORS OR OMISSIONS IN THE EOR'S DRAWINGS AND THE PERFORMANCE OF THE WORK BY THE CONTRACTOR ALL WORK AND MATERIAL SHALL MEET THE REQUIREMENTS OF ALL LOCAL AND STATE BUILDING CODES AND THE SPECIFICATIONS OF THE NATIONAL BOARD OF FIRE UNDERWRITERS. THE DRAWINGS SHOW THE GENERAL ARRANGEMENTS AND EXTENT OF THE WORK. AS THE WORK PROGRESSES. THE OWNER AND THE CONTRACTOR. AT NO EXTRA COSTS. SHALL MAKE MODIFICATIONS TO MAKE THE PARTS ALIGN. ALL WORK AND MATERIALS SHALL MEET THE REGUIREMENTS OF LOCAL AND STATE CODES AND THE SPECS OF THE NATIONAL BOARD OF FIRE UNDERWRITERS. CONTRACTORS SHALL CHECK AND VERIFY ALL PLAN DIMENSIONS AND CONDITIONS BEFORE PROCEEDING CONSTRUCTION. THE CONTRACTOR SHALL REPORT ANY DISCREPANCIES TO THE FOR FOR CORRECTION PRIOR TO BEGINNING ANY WORK. THE DISCOVERY OF DISCREPANCIES AFTER THE BEGINNING OF WORK WILL BE EVIDENCE OF FAULTY WORK AND SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR DO NOT SCALE DRAWINGS. ALL WRITTEN DIMENSIONS GOVERN. THE CONTRACTOR FOR THIS PROJECT SHALL INCLUDE ALL MATERIALS AND LABOR REQUIRED TO COMPLETE THE TOTAL PROJECT. THE CONTRACTOR SHALL FURNISH AND PAY FOR ALL MATERIALS. TOOLS. EQUIPMENT. LABOR. MACHINERY. TRANSPORTATION. HEAT. WATER. UTILITIES. AND ALL OTHER FACILITIES AND SERVICES REQUIRED FOR THE SAFE AND PROPER EXECUTION AND COMPLETION OF THE WORK. THE FOR SHALL BE THE INTERPRETER OF THE CONTRACT DOCUMENTS. THE DOCUMENTS SHOW AN OVERVIEW OF THE WORK REQUIRED UNDER THIS CONTRACT AND RELATED REQUIREMENTS AND CONDITIONS THAT WILL IMPACT THE PROJECT. ALL DRAWINGS ARE COMPLIMENTARY. THE DRAWINGS GENERALLY SHOW THE INTENT OF THE OVERALL COMPLEXITY AND CONCEPTS OF THE PROJECT. AND DO NOT NECESSARILY SHOW ALL DETAILS AND CONDITIONS. ALL NEW INTERIOR CONCRETE SLABS AND FOUNDATION WALLS AND FOOTINGS SHALL HAVE SOIL POISONING UNDER NEW WORK AND SHALL BE INSTALLED BY A LICENSED CONTRACTOR. ALL WORK SHALL BE COMPLETED IN ACCORDANCE WITH ALL STATE AND DEPARTMENT OF AGRICULTURE, STRUCTURAL PEST CONTROL DIVISION REGULATIONS, RULES. DEFINITIONS AND REQUIREMENTS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING AND MAINTAINING ALL EXISTING SETBACKS. EASEMENTS. AND ANY DEED RESTRICTIONS. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR FINAL CLEAN-UP AND DEBRIS REMOVAL 7 L SECTION 506 STRUCTURAL 506.1 GENERAL. REPAIRS OF STRUCTURAL ELEMENTS SHALL COMPLY WITH THIS SECTION. 506.1.1 NONSTRUCTURAL REPAIRS EXCLUSIVE OF FIXTURES AND FURNITURE. THE COST OF WHICH DOES NOT EXCEED 25 PERCENT OF THE REPLACEMENT VALUE OF THE EXISTING BUILDING OR STRUCTURE. WITH THE APPROVAL OF THE BUILDING OFFICIAL. MAY BE MADE OF THE SAME MATERIAL OF WHICH THE BUILDING OR STRUCTURE IS CONSTRUCTED. EXCEPTION: HISTORIC BUILDINGS SHALL COMPLY WITH SECTION 502.3. 506.1.1.1 EVALUATION AND DESIGN PROCEDURES. RESERVED. 506.1.1.2 IBC LEVEL SEISMIC FORCES. RESERVED. TABLE 506.1.1.2 FEMA 356 AND ASCE 31 PERFORMANCE LEVELS. RESERVED. 506.1.1.3 REDUCED IBC LEVEL SEISMIC FORCES. RESERVED. 506.1.2 WIND DESIGN. WIND DESIGN OF EXISTING BUILDINGS SHALL BE IN ACCORDANCE WITH THE BUILDING CODES THAT WERE IN EFFECT WHEN THE BUILDING WAS PERMITTED. 506.2 REPAIRS TO DAMAGED BUILDINGS. REPAIRS TO DAMAGED BUILDINGS SHALL COMPLY WITH THIS SECTION AND SECTION 611. REROOFING. 506.2.1 DANGEROUS CONDITIONS. REGARDLESS OF THE EXTENT OF STRUCTURAL DAMAGE. DANGEROUS CONDITIONS SHALL BE ELIMINATED. 506.2.2 SUBSTANTIAL STRUCTURAL DAMAGE TO ELEMENTS OF THE LATERAL -FORCE -RESISTING SYSTEM. A BUILDING THAT HAS SUSTAINED SUBSTANTIAL STRUCTURAL DAMAGE TO THE ELEMENTS OF ITS LATERAL -FORCE -RESISTING SYSTEM SHALL BE EVALUATED AND REPAIRED IN ACCORDANCE WITH THE APPLICABLE PROVISIONS OF SECTIONS 506.2.2.1 THROUGH 506.2.2.3. 506.2.2.1 EVALUATION. THE BUILDING SHALL BE EVALUATED BY A REGISTERED DESIGN PROFESSIONAL. AND THE EVALUATION FINDINGS SHALL BE SUBMITTED TO THE CODE OFFICIAL. THE EVALUATION SHALL ESTABLISH WHETHER THE DAMAGED BUILDING. IF REPAIRED TO ITS PREDAMAGED STATE. WOULD COMPLY WITH THE PROVISIONS OF THE CODES THAT WERE IN EFFECT WHEN THE BUILDING WAS PERMITTED. WIND FORCES FOR THIS EVALUATION SHALL BE THOSE PRESCRIBED IN THE CODES THAT WERE IN EFFECT WHEN THE BUILDING WAS PERMITTED. 506.2.2.2 EXTENT OF REPAIR FOR COMPLIANT BUILDINGS. IF THE EVALUATION ESTABLISHES COMPLIANCE OF THE PREDAMAGED BUILDING IN ACCORDANCE WITH SECTION 506.2.2.1, REPAIRS SHALL BE PERMITTED THAT RESTORE THE BUILDING TO ITS PREDAMAGED STATE USING MATERIALS AND STRENGTHS THAT EXISTED PRIOR TO THE DAMAGE. 506.2.2.3 EXTENT OF REPAIR FOR NONCOMPLIANT BUILDINGS. IF THE EVALUATION DOES NOT ESTABLISH COMPLIANCE OF THE PREDAMAGED BUILDING IN ACCORDANCE WITH SECTION 506.2.2.1. THE BUILDING SHALL BE REHABILITATED TO COMPLY WITH APPLICABLE PROVISIONS OF THE FLORIDA BUILDING CODE. BUILDING FOR LOAD COMBINATIONS. INCLUDING WIND. THE WIND DESIGN LEVEL FOR THE REPAIR SHALL BE AS REQUIRED BY THE BUILDING CODE IN EFFECT AT THE TIME OF ORIGINAL CONSTRUCTION, UNLESS THE DAMAGE WAS CAUSED BY WIND. IN WHICH CASE THE DESIGN LEVEL SHALL BE AS REQUIRED BY THE CODE IN EFFECT AT THE TIME OF ORIGINAL CONSTRUCTION OR AS REQUIRED BY THE FLORIDA BUILDING CODE, BUILDING , WHICHEVER IS GREATER. NEW STRUCTURAL MEMBERS AND CONNECTIONS REQUIRED BY THIS REHABILITATION DESIGN SHALL COMPLY WITH THE DETAILING PROVISIONS OF THE FLORIDA BUILDING CODE. BUILDING FOR NEW BUILDINGS OF SIMILAR STRUCTURE, PURPOSE AND LOCATION. 506.2.3 SUBSTANTIAL STRUCTURAL DAMAGE TO VERTICAL LOAD -CARRYING COMPONENTS. VERTICAL LOAD -CARRYING COMPONENTS THAT HAVE SUSTAINED SUBSTANTIAL STRUCTURAL DAMAGE SHALL BE REHABILITATED TO COMPLY WITH THE APPLICABLE PROVISIONS FOR DEAD AND LIVE LOADS IN THE FLORIDA BUILDING CODE. BUILDING. UNDAMAGED VERTICAL LOAD -CARRYING COMPONENTS THAT RECEIVE DEAD OR LIVE LOADS FROM REHABILITATED COMPONENTS SHALL ALSO BE REHABILITATED TO CARRY THE DESIGN LOADS OF THE REHABILITATION DESIGN. NEW STRUCTURAL MEMBERS AND CONNECTIONS REQUIRED BY THIS REHABILITATION DESIGN SHALL COMPLY WITH THE DETAILING PROVISIONS OF THE FLORIDA BUILDING CODE. BUILDING FOR NEW BUILDINGS OF SIMILAR STRUCTURE. PURPOSE AND LOCATION. 506.2.3.1 LATERAL -FORCE -RESISTING ELEMENTS. REGARDLESS OF THE LEVEL OF DAMAGE TO ELEMENTS OF THE LATERAL - FORCE -RESISTING SYSTEM. IF SUBSTANTIAL STRUCTURAL DAMAGE TO VERTICAL LOAD -CARRYING COMPONENTS WAS CAUSED PRIMARILY BY WIND EFFECTS. THEN THE BUILDING SHALL BE EVALUATED IN ACCORDANCE WITH SECTION 506.2.2.1 AND. IF NONCOMPLIANT. REHABILITATED IN ACCORDANCE WITH SECTION 506.2.2.3. 506.2A LESS THAN SUBSTANTIAL STRUCTURAL DAMAGE. FOR DAMAGE LESS THAN SUBSTANTIAL STRUCTURAL DAMAGE, REPAIRS SHALL BE ALLOWED THAT RESTORE THE BUILDING TO ITS PREDAMAGED STATE USING MATERIALS AND STRENGTHS THAT EXISTED PRIOR TO THE DAMAGE. NEW STRUCTURAL MEMBERS AND CONNECTIONS USED FOR THIS REPAIR SHALL COMPLY WITH THE DETAILING PROVISIONS OF THE FLORIDA BUILDING CODE. BUILDING FOR NEW BUILDINGS OF SIMILAR STRUCTURE, PURPOSE AND LOCATION. 506.2.5 FLOOD HAZARD AREAS. SEE SECTION 501.4. SECTION 507 ELECTRICAL 507.1 MATERIAL. EXISTING ELECTRICAL WIRING AND EQUIPMENT UNDERGOING REPAIR SHALL BE ALLOWED TO BE REPAIRED OR REPLACED WITH LIKE MATERIAL IN ACCORDANCE WITH CHAPTER 27 OF THE FLORIDA BUILDING CODE. BUILDING. EXCEPTIONS: I. EXISTING ELECTRICAL WIRING AND EQUIPMENT UNDERGOING REPAIR SHALL BE PERMITTED TO BE REPAIRED OR REPLACED WITH LIKE MATERIAL. 2. FOR REPLACEMENT OF NONGROU N DING -TYPE RECEPTACLES WITH GROUNDING -TYPE RECEPTACLES AND FOR BRANCH CIRCUITS THAT DO NOT HAVE AN EQUIPMENT GROUNDING CONDUCTOR IN THE BRANCH CIRCUITRY. THE GROUNDING CONDUCTOR OF A GROUNDING -TYPE RECEPTACLE OUTLET SHALL BE PERMITTED TO BE GROUNDED TO ANY ACCESSIBLE POINT ON THE GROUNDING ELECTRODE SYSTEM OR TO ANY ACCESSIBLE POINT ON THE GROUNDING ELECTRODE CONDUCTOR. IN ACCORDANCE WITH ARTICLE 250.130 (C) OF CHAPTER 27 OF THE FLORIDA BUILDING CODE. BUILDING. 3. FRAMES OF ELECTRIC RANGES. WALL -MOUNTED OVENS. COUNTER -MOUNTED COOKING UNITS. CLOTHES DRYERS. AND OUTLET OR JUNCTION BOXES THAT ARE PART OF THE EXISTING BRANCH CIRCUIT FOR THESE APPLIANCES SHALL BE PERMITTED TO BE GROUNDED TO THE GROUNDED CIRCUIT CONDUCTOR IN ACCORDANCE WITH ARTICLE 250.140 OF CHAPTER 27 OF THE FLORIDA BUILDING CODE. BUILDING . 507.1.1 RECEPTACLES. REPLACEMENT OF ELECTRICAL RECEPTACLES SHALL COMPLY WITH THE APPLICABLE REQUIREMENTS OF SECTION 406.3(D) OF NFPA 70. 507.1.2 PLUG FUSES. PLUG FUSES OF THE EDISON-BASE TYPE SHALL BE USED FOR REPLACEMENTS ONLY WHERE THERE IS NO EVIDENCE OF OVER FUSING OR TAMPERING PER APPLICABLE REQUIREMENTS OF SECTION 240.51(B) OF NFPA 70. 507.1.3 NONG ROUNDING -TYPE RECEPTACLES. FOR REPLACEMENT OF NONGROUNDING-TYPE RECEPTACLES WITH GROUNDING -TYPE RECEPTACLES AND FOR BRANCH CIRCUITS THAT DO NOT HAVE AN EQUIPMENT GROUNDING CONDUCTOR IN THE BRANCH CIRCUITRY. THE GROUNDING CONDUCTOR OF A GROUNDING -TYPE RECEPTACLE OUTLET SHALL BE PERMITTED TO BE GROUNDED TO ANY ACCESSIBLE POINT ON THE GROUNDING ELECTRODE SYSTEM OR TO ANY ACCESSIBLE POINT ON THE GROUNDING ELECTRODE CONDUCTOR IN ACCORDANCE WITH SECTION 250.130(C) OF NFPA 70. 507.1.4 GROUP 1-2 RECEPTACLES. NON "HOSPITAL GRADE" RECEPTACLES IN PATIENT BED LOCATIONS OF GROUP 1-2 SHALL BE REPLACED WITH -HOSPITAL GRADE- RECEPTACLES. AS REQUIRED BY NFPA 99 AND ARTICLE 517 OF NFPA 70. 507.1.5 GROUNDING OF APPLIANCES. FRAMES OF ELECTRIC RANGES. WALL -MOUNTED OVENS. COUNTER -MOUNTED COOKING UNITS. CLOTHES DRYERS AND OUTLET OR JUNCTION BOXES THAT ARE PART OF THE EXISTING BRANCH CIRCUIT FOR THESE APPLIANCES SHALL BE PERMITTED TO BE GROUNDED TO THE GROUNDED CIRCUIT CONDUCTOR IN ACCORDANCE WITH SECTION 250.140 OF NFPA 70. SECTION 508 MECHANICAL 508.1 GENERAL. EXISTING MECHANICAL SYSTEMS UNDERGOING REPAIR SHALL COMPLY WITH SECTION 301.11 OF THE FLORIDA BUILDING CODE. MECHANICAL AND SHALL NOT MAKE THE BUILDING LESS CONFORMING THAN IT WAS BEFORE THE REPAIR WAS UNDERTAKEN. SECTION 509 PLUMBING 509.1 MATERIALS. PLUMBING MATERIALS AND SUPPLIES SHALL NOT BE USED FOR REPAIRS THAT ARE PROHIBITED IN THE FLORIDA BUILDING CODE. PLUMBING. 509.2 PLUMBING FIXTURE REPLACEMENT. WHEN ANY PLUMBING FIXTURE IS REPLACED. THE REPLACEMENT PLUMBING FIXTURE SHALL COMPLY WITH THE FLORIDA BUILDING CODE, PLUMBING. EXCEPTION: BLOWOUT -DESIGN WATER CLOSETS [3.5 GALLONS (13 L) PER FLUSHING CYCLE] P R301.1 DESIGN. BUILDINGS AND STRUCTURES, AND ALL PARTS THEREOF. SHALL BE CONSTRUCTED TO SAFELY SUPPORT ALL LOADS. INCLUDING DEAD LOADS LINE LOADS. ROOF LOADS. FLOOD LOADS AND WIND LOADS AS PRESCRIBED BY THIS CODE. THE CONSTRUCTION OF BUILDINGS AND STRUCTURES SHALL RESULT IN A SYSTEM THAT PROVIDES A COMPLETE LOAD PATH CAPABLE OF TRANSFERRING ALL LOADS FROM THEIR POINT OF ORIGIN THROUGH THE LOAD -RESISTING ELEMENTS TO THE FOUNDATION. EXCEPTION: BUILDINGS AND STRUCTURES LOCATED WRHIN THE HIGH -VELOCITY HURRICANE ZONE SHALL COMPLY ONLY WITH SECTIONS R302 TO R324. INCLUSIVE AND THE PROVISIONS OF CHAPTER 44. R301.1.1 ALTERNATIVE PROVISKNdS AS AN ALTERNATIVE TO THE REQUIREMENTS IN SECTION R301.1 THE FOLLOWING STANDARDS ARE PERMITTED SUBJECT TO THE LIMITATIONS OF THIS CODE AND THE UMITATIONS THERE IN. WHERE ENGINEERED DESIGN IS USED IN CONJUNCTION WITH THESE STANDARDS THE DESIGN SHALL COMPLY WITH THE FLORIDA BUILDING CODE. BUILDING. I. AMERICAN FOREST AND PAPER ASSOCIATION (AFSPA) WOOD FRAME CONSTRUCTION MANUAL (WFCM). 2. AMERICAN IRON AND STEEL INSTITUTE (AISI). STANDARD FOR COLD -FORMED STEEL FRAMING PRESCRIPTIVE METHOD FOR ONE- AND TWO-FAMILY DWELLINGS (COFS/PM). R301.1.2 CONSTRUCTION SYSTEMS THE REQUIREMENTS OF THIS CODE ARE BASED ON PLATFORM AND BALLOON -FRAME CONSTRUCTION FOR LIGHT -FRAME BUILDINGS. THE REQUIREMENTS FOR CONCRETE AND MASONRY BUILDINGS ARE BASED ON A BALLOON FRAMING SYSTEM. OTHER FRAMING SYSTEMS MUST HAVE EQUIVALENT DETAIUNG TO ENSURE FORCE TRANSFER, CONTINUITY AND COMPATIBLE DEFORMATIONS. R30H 3 ENGINEERED DESIGN. WHEN A BUILDING OF OTHERWISE CONVENTIONAL CONSTRUCTION CONTAINS STRUCTURAL ELEMENTS EXCEEDING THE LIMITS OF SECTION R301 OR OTHERWISE. NOT CONFORMING TO THIS CODE. THESE ELEMENTS SHALL BE DESIGNED IN ACCORDANCE WITH ACCEPTED ENGINEERING PRACTICE. THE EXTENT OF SUCH DESIGN NEED ONLY DEMONSTRATE COMPLIANCE OF NONCONVENTIONAL ELEMENTS WITH OTHER APPLICABLE PROVISIONS AND SWILL BE COMPATIBLE WfTH THE PERFORMANCE OF THE CONVENTIONAL FRAMED SYSTEM. ENGINEERED DESIGN IN ACCORDANCE WITH THE FLORIDA BUILDING CODE, BUILDING IS PERMITTED FOR ALL BUILDINGS AND STRUCTURES. AND PARTS THEREOF. INCLUDED IN THE SCOPE OF THIS CODE. 5 I 4 ROOFING ROOFING MUST BE STRONG ENOUGH TO STAY INTACT IN THE ESTIMATED HIGHEST WINDS OF THE AREA BY THE MANUFACTURE'S INSTALLATION INSTRUCTIONS AND TEST DATA THAT PROVES THE STRENGTH OF THE SHINGLE. INSPECTIONS INSPECTIONS SHALL BE MADE ACCORDING TO THE PROVISIONS AND GUIDLINES OF THE FBC 2004 SECTION 109 FOUNDATION INSPECTION: A FOUNDATION SURVEY SHALL BE PERFORMED AND A COPY OF THE SURVEY SHALL BE ON THE SITE FOR THE BUILDING INSPECTOR'S USE OR ALL PROPERTY MARKERS SHALL BE EXPOSED AND A STRING STRETCHED FROM MARKER TO MARKER TO VERIFY REQUIRED SETBACKS. ALL WORK SHALL COMPLY WITH PREVAILING CODES, LOCAL BUILDING 6 ALUMINUM. 3 2 I�1 C C E F1 Cr H RADIANTZH IMPACT CG12-016 �. CONNELLY GROUP CC N 6 U L T I N G EN0I NEERS 200 2nd Ave South - #455 - St Petersburg, FL 33701 N CD? info®connallyenginsering.com [T)813.232.8448 [F)800.69B. 1 94 5 IQ www.ccnneIIyenginIsaring.com FBC 2007REV09. CHAPTER I PROJECT IOWI PERMIT INTENT DATA i' i U S WILL BE CONSTRUCTED TO BE A LCENSE TO PROCEED WITH THE WORK AND NOT AS AUTHORITY TO VIOLATE. CANCEL. ALTER OR SET DESIGNER < ASIDE ANY OF THE PROVISIONS OF THE TECHNICAL CODES. NOR SHALL ISSUANCE OF A PERMIT PREVENT THE BUILDING OFFICIAL FROM THEREAFTER REQUIRING A CORRECTION OF ERRORS IN FILMS. CONSTRUCTION OR VIOLATIONS OF THIS CODE. EVERY PERMIT ISSUED SHALL BECOME INVALID CRC DRAWN BY ,e. UNLESS THE WORK AUTHORIZED BY SUCH PERMIT IS COMMENCED WITHIN SIX MONTHS Ld AFTER ITS ISSUANCE. OR IF THE WORK AUTHORIZED BY SUCH PERMIT IS SUSPENDED OR ABANDONED FOR A PERIOD OF SIX MONTHS AFTER THE TIME THE WORK IS COMMENCED. JJC CHECKED §. I~ WE HEREBY CERTIFYTHAT THESE PINS AND SPEOFK;ATKNJSCOMPLYWITH TTHE REE REQUIREMENTS OF THE APPLICABLE BUILDING CODES SPECIFIED ON THE SHEET CRC LU NORTH 4 I _ I 3 1 2 1 1 10 I 9 I 8 I 7 STRUCTURAL NOTES: 1 - GENERAL hl ALL DESIGN SHALL BE IN ACCORDANCE WITH THE FOLLOWING CODES AND DESIGN A SPECIFICATIONS A BUILDING CDDE 1 fbc2007REV09 B STRUCTURAL CONCRETPBUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE(ACI 318) C STRUCTURAL STEELISPECIFICATION FOR STRUCTURAL STEEL BUILDINGS (AISC) D CONCRETE MASONRY;BUILDING CODE REQUIREMENTS FOR MASONRY STRUCTURESOCI C C E F G H C PRIOR TO BEGINNING CONSTRUCTION, PREPARE EXISTING CONDITIONS VIDED, REFER TO 4,5 REINFORCEMENT SECTION 01500, 'CONSTRUCTION FACILITIES AND TEMPORARY SERVICES', A ALL REINFORCING STEEL TO CONFORM TO ASTM A615 GRADE 60. D ALL OMISSIONS OR CONFLICTS BETWEEN THE VARIOUS ELEMENTS OF THE DRAWINGS AND/OR B SPLICE LAPS SHALL BE A MINIMUM OF 30 BAR DIAMETERS, UNLESS NOTED OTHERWISE. PROVIDE SPECIFICATIONS SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER BEFORE PROCEEDING DOWELS BETWEEN FOOTINGS AND WALLS OR PIERS TO MATCH SIZE AND SPACING OF VERTICAL WITH ANY WORK. REINFORCING. E VERIFY AND COORDINATE THE LOCATIONS AND SIZE OF ALL OPENINGS AND SLEEVES THROUGH C EPDXY COATING OF DOWEL BARS SHALL BE THE SAME AS SPECIFIED FOR THE REINFORCEMENT TO FLOORS, WALLS AND ROOFS WITH MECHANICAL AND ELECTRICAL AND WITH EQUIPMENT BE SPLICED. FURNISHED. D WELDING FOR STEEL REINFORCING BARS AWS D 1.4, F VERIFY STRUCTURAL ELEVATIONS AND DIMENSIONS WITH ARCH DRAWINGS E WELDED WIRE FABRIC SHEETS TO CONFIRM PER ASTM A185 G VERIFY LOCATIONS OF FLOOR DRAINS INSERTS AND OTHER RELATED ITEMS F THE CONCRETE PROTECTION SHALL BE PER ACI 3621R EXCEPT AS NOTED ON THE DRAWINGS AND 6 - STEEL JOISTS 6.1 STEEL JOISTS & COMPOSITE CONCRETE SLAB (OR APPROVED EQUAL) SHALL BE DESIGNED TO SUPPORT THE REQUIRED LIVE LOADS, SHALL CONFORM TO THE REQUIREMENTS OF AISC, 6.2 CONCRETE SLAB SHALL BE 3' THICK WITH 6x6-6/6 W,W,F. AS DESIGN BY THE SPECIALITY CONTRACTOR, 6.3 STEEL JOISTS AND DECKING SHALL BE FABRICATED ACCORDING TO SPECIFICATIONS AS PUBLISHED BY THE STEEL JOIST INSTITUTE (SJI) AND THE STEEL DECK INSTITUTE (SDI), LATEST EDITIONS 530 SPECIFIED HEREIN SPECIFIC DRAWINGS OR DETAILS MAY OR MAY NOT INDICATE EPDXY COATING OR 7 - LIGHT GAGE METAL FRAMING (LGS) E COMPONENTS AND CLADDING LOADSIMINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER UNCOATED REINFORCING. IN AREAS OF DISPUTE THIS SCHEDULE SHALL GOVERN IN ALL CASES. STRUCTURES(ASCE 7-05) 71 LIGHT GAGE STEEL FRAMING SHALL BE DESIGNED AND CONSTRUCTED IN ACCORDANCE WITH H NO STRUCTURAL MEMBERS SHALL BE CUT FOR PIPES, DUCTS ETC. UNLESS SPECIFICALLY DETAILED OR APPROVED IN WRITING BY THE ENGINEER. 1.2 USE GROUP I FIELD VERIFY THE LOCATIONS OF EXISTING STRUCTURES IF ANY, PIPING CONDUITS DUCTWORK ETC ORDINARY HAZARD, GROUP B AND NOTIFY THE ENGINEER OF INTERFERENCE NOT NOTED ON THE PLANS, 1.3 DESIGN CRITERIA J FLOOR SLAB ELEVATIONS INDICATED ON THE DRAWINGS ARE ESTABLISHED TO PROVIDE POSITIVE A LIVE LOADS DRAINAGE AND TO PROVIDE REQUIRED HEADROOM CLEARANCE, NOTIFY THE ENGINEER OF GRADES ROOF 20 PSF REDUCIBLE WHICH DO NOT ALLOW FOR THE MINIMUM HEADROOM CLEARANCE. FLOORS 40 PSF K DO NOT SCALE THE DRAWINGS STAIRS 100 PSF LIGHT STORAGE 125 PSF L VISIT TO THE JOB SITE BY THE ENGINEER TO OBSERVE THE CONSTRUCTION DOES NOT IN ANY WAY DESCRIPTION COVER PROTECTIO WALLS NOT IN CONTACT W/ EARTH 1 1/2" UNCOATED WALLS IN 2° CONTACT W/ EARTH UNCOATED FOOTING WALLS CAST 3^ AGAINST EARTH UNCOATED FRAMED FLOORS 3 4" UNCOATED SLAB ON -GRADE MID -DEPTH, UNCOATED UNO FBC, CHAPTER 22 AND AISI, LATEST EDITION. ALL STEEL DESIGNATIONS SHALL BE IN ACCORDANCE WITH STEEL STUD MANUFACTURER'S ASSOCIATION (SSMA) TECHNICAL REPORT ICBD ER-4943P REFER TO REPORT FOR STEEL SIZES AND STANDARD DESIGNATIONS 72 EXTERIOR WALL FRAMING SHALL BE DESIGNED FOR THE FOLLOWING MAXIMUM LATERAL DEFLECTIONS, AT THE APPLICABLE DESIGN WIND : -- AT MASONRY VENEER L/600 OR 0,3 INCH., WHICHEVER IS LESS -- AT OTHER LOCATIONS L/360 T3 SUBMIT SHOP DRAWINGS WHICH SHALL INCLUDE ERECTION DRAWINGS SHOWING MEMBER LAYOUT, SIZE AND SPACING. PROVIDE CONNECTION DETAILS SUPPLEMENTAL BRACING, SPLICES, ACCESSORIES, AND DETAILS AS MAY BE REQUIRED FOR PROPER INSTALLATION. B GROUND SNOW LOAD (Pg) n/a MEAN THE GUARANTEE OF THE CONTRACTORS WORK, NOR RESPONSIBILITY FOR COORDINATION, SUPERVISION NOR SAFETY AT THE JOB SITE. G PLACING PLANS AND SHOP FABRICATION DETAILS SHALL BE IN ACCORDANCE WITH THE MANUAL 7.4 MATERIALS AND FINISHES, OF STANDARD PRACTICE FOR DETAILING REINFORCED CONCRETE STRUCTURES'. FURNISH SUPPORT 2.2 FORMWORK & SHORING BARS AND ACCESSORIES IN ACCORDANCE WITH C,R,S,I, STANDARDS, 1. FOR 16-GAGE AND HEAVIER UNITS, FABRICATE METAL FRAMING COMPONENTS OF STRUCTURAL QUALITY STEEL SHEET WITH A MINIMUM YIELD POINT OF 50,000 PSI; A DRAWINGS DO NOT INCLUDE THE NECESSARY COMPONENTS FOR THE SAFETY OF THE BUILDINGS 4,6 CONCRETE ACCESSORIES ASTM A653 GRADE C OR D. OR EQUIPMENT DURING CONSTRUCTION, THE CONTRACTOR IS RESPONSIBLE FOR ALL WORK RELATING TO CONSTRUCTION, ERECTION METHODS, BRACING, SHORING, RIGGING GUYS SCAFFOLDING FORMWORK A FABRICATE & PROVIDE STANDARD SUPPORTING ACCESSORIES IN ACCORDANCE WITH THE ACI MANUAL 2. FOR 18-GAGE AND LIGHTER UNITS, FABRICATE METAL FRAMING COMPONENTS OF AND OTHER WORK AIDS REQUIRED TO SAFELY PERFORM THE WORK INDICATED. OF STANDARD PRACTICE FOR DETAILING REINFORCED CONCRETE STRUCTURES ACI 315. COMMERICAL QUALITY STEEL SHEET WITH A MINIMUM YIELD POINT OF 33,000 PSI; ASTM A653 GRADE A, C WIND LOADS B CONTRACTOR IS RESPONSIBLE FOR PROVIDING APPROPRIATE SHORING, REFER TO SECTION 03100 B MISCELLANEOUS STEEL SHAPE PLATES AND BARS ASTM A36, HOT DIP GALVANIZED AFTER ASSEMBLY, 'CONCRETE FORM WORK' STAINLESS STEEL ASTM A6666 TYPE 304L AS NOTED ON THE DRAWINGS 3. PROVIDE GALVANIZED FINISH TO METAL FRAMING COMPONENTS COMPLYING WITH WIND SPEED 120 mph ASTM A924 FOR MINIMUM G60 COATING, WIND LOAD IMPORTANCE FACTOR 100 3 - SITE WORK C ANCHOR BOLTS / BASE PLATES ASTM A36 HOT DIP GALVANIZED. 4, ALL STUDS SHALL BE STANDARD LOAD -BEARING STEEL STUDS OF SIZE, SHAPE, AND WIND EXPOSURE CATEGORY B GAGE INDICATED, WITH 1,625' FLANGE AND FLANGE RETURN LIP, INTERNAL PRESSURE COFFICIENT Gcpi ±0,18 (ENCLOSED) 3A FOUNDATIONS 4.7 GENERAL CAST IN PLACE CONCRETE A FOUNDATIONS ARE DESIGNED TO BEAR ON ENGINEERED FILL OR NATURAL SOIL WITH A CAPACITY A REINFORCEMENT 75 WELD STUD WORK USING E60XX ELECTRODES BY CERTIFIED WELDERS. FOR MECHANICAL D SEISMIC (n/a) OF 2000 PSF (uno), THIS VALUE IS TO BE VERIFIED IN THE FIELD BY THE BUILDING INSPECTOR FASTENERS, USE ONLY POLYMER FINISHES, CHROMIUM PLATED, STAINLESS STEEL OR OR A QUALIFIED TESTING AGENCY. Al PROVIDE STANDARD 90^ BAR HOOKS UNLESS NOTED OTHERWISE ON THE DRAWINGS, HOT DIP GALVANIZED UNITS B IN ORDER TO PROVIDE ADEQUATE FROST PROTECTION, top OF EXPOSURE FOUNDATIONS A2 REINFORCING STEEL SHALL NOT BE BENT OR STRAIGHTENED UNLESS APPROVED BY THE ENGINEER T6 CONSTRUCT ALL NON -LOAD BEARING WALLS WITH A VERTICAL SLIP CONNECTION AT THE SHALL BE PLACED A MINIMUM OF 24 INCHes BELOW THE ADJACENT GRADE, BACKFILL FOR ANY OR AS INDICATED ON THE DRAWINGS. TOP OF THE WALL, EXPOSED RETAINING WALLS SHOULD BE ATLEAST 1 FOOT EF DOT NO, 57 CRUSHED STONE IMMEDIATELY BEHIND THE WALL FOR FROST PROTECTION A3 FIELD CUTTING OF REINFORCEMENT IS PROHIBITED UNLESS APPROVED BY THE ENGINEER, 3.2 GENERAL - SITE WORK A4 WELDING OF REINFORCEMENT IS PROHIBITED UNLESS SPECIFICALLY CALLED FOR ON THE DRAWINGS 8 - STEEL LINTELS -BRICK ONLY OR APPROVED BY THE ENGINEER. A SLABS ON GRADE SHALL BE MIN 4' THK, CONCRETE SLAB REINFORCED W/ 6x6 - W14xWL4 WWF, A5 DO NOT WELD EPDXY COATED REINFORCING, ARCH. ARE SELF SUPPORTING. UND, SLABS ON GRADE SHOULD BE SUPPORTED ON PROPERLY COMPACTED FILL AND RESIDUAL SOILS, A MODULUS OF SUB GRADE REACTION OF 125 PCI IS USED TO DESIGN THE FLOOR SLABS. THE FOR ALL OPENINGS AND RECESSES IN BRICK WILLS, PROVIDE ONE STEEL ANGLE FOR CONTRACTOR SHOULD RE -COMPACT FLOOR SLAB SUB -GRADE IMMEDIATELY PRIOR TO PLACING B ACCESSORIES EACH 4' OF WALL THICKNESS AS FOLLOWS; MOISTURE BARRIER MATERIALS AND STONE TO REPAIR ANY DISTURBANCE THAT MAY OCCUR DUE TO L 3 112' x 3 1/2' x 1/4' FOR OPENINGS UP TO 4'-0' OTHER CONSTRUCTION OPERATION. A 4 INCH CLEAN STONE GRAVEL BED SHOULD UNDERLIE ALL B1 ALL WELD ASSEMBLIES SHALL USE E70XX LOW HYDROGEN ELECTRODES MINIMUM WELD SIZE L 6' x 3 112' x 3/8' FOR OPENINGS 4'-0' TO 6'-0' FLOOR SLABS ON GRADE TO PROVIDE A PROPER MOISTURE BARRIER. THIS SHOULD CONSIST OF DOT STAINLESS STEEL ELECTRODES SHALL BE OF TYPE 347. W8xl0 WITH SUSPENDED 1/4' PLATE SAME WIDTH AS WALL FOR OPENINGS GREATER NO. 68 OR 57 CRUSHED STONE THAT SHOULD BE DENSIFIED WITH A VIBRATORY ROLLER PRIOR TO THAN 6'-0', UNLESS NOTED. PROVDE 6' MINIMUM BEARING AT EACH END. PLACEMENT OF CONCRETE. B2 NO ALUMINUM CONDUIT OR PRODUCTS CONTAINING ALUMINUM OR ANY OTHER MATERIAL INJURIOUS TO THE CONCRETE SHALL BE EMBEDDED TO THE CONCRETE, Wgx10 FOR OPENING 6'-0' TO 9'-0' B COMPACTED BACKFILL MATERIAL BELOW BUILDING SLABS AND FOOTING MUST BE APPROVED BY W10xl2 FOR OPENING 9'-0' TO 12'-0' GEOTECHNICAL ENGINEER PRIOR TO PLACEMENT. THE BACKFILL MATERIAL SHOULD BE FREE FROM C JOINT W12x19 FOR OPENING 12'-0' TO 15'-0' 1,4 CORROSION PROTECTION SYSTEM VEGETATION AND OTHER DELETERIOUS MATTER AND SHALL NOT CONTAIN LUMPS OR ROCK HAVING A DIAMETER GREATER THAN 6 INCHES. Cl PROVIDE}' CHAMFER ON EXPOSED CORNERS OF CONCRETE UNLESS NOTED OTHERWISE ON A CONCRETE ACCESSORIES TO BE HOT DIPPED GALVANIZED AND OR STAINLESS STEEL AS DRAWINGS, SPECIFIED HEREIN. C ALL FILL SHOULD BE PLACED IN LAYERS NOT TO EXCEED 8 INCHES LOOSE LIFT AND COMPACTED 9 - HANDRAILS & STAIRS TO AT LEAST 95% OF MAXIMUM DRY DENSITY AND WITHIN 5Z OF OPTIMUM MOISTURE ACCORDING C2 TOOL SLAB JOINT AT THE TIME OF FINISHING SAW CUTTING IS NOT ALLOWED B FOR FIELD WELDING GALVANIZED CONNECTION HARDWARE, REMOVE SLAG, WIRE BRUSH AND TO ASTM D-698, COMPACTED FILL SUB -GRADE STEEPER THAN 4H1V SHOULD BE BENCHED TO APPLY THREE COATS OF ZRC COLD GALVANIZING. ALLOW PLACEMENT OF HORIZONTAL LIFTS, A QUALIFIED ENGINEERING TECHNICIAN UNDER THE C3 CONSTRUCTION AND CONTROL JOINTS FOR SLABS ON GRADE -CAST IN STRIPS 20' '-0' BY 100'-0 STAIRCASE LOAD ASSUMED DIRECT SUPERVISION OF A GEOTICHNICAL ENGINEER SHOULD PERFORM A MINIMUM OF 3 TESTS MAXIMUM. SPACE JOINTS AT 20'-0' ON CENTER UNLESS OTHERWISE NOTED ON THE DRAWINGS. PER LAYER OF FILL TO ASSURE THAT ADEQUATE COMPACTION IS ACHIEVED. COMPACTED STRUCTURAL 1, DEAD LOAD 100 PSF 1.5 SEE ARCHITECTURAL DRAWINGS FOR ANGLES, CLIPS, PLATES, ETC„ AND OTHER MISCELLANEOUS FILL SHOULD EXTEND ATLEAST 5 FEET BEYOND LIMITS, COMPACTED FILL SLOPES SHOULD NOT BE D THERMAL AND MOISTURE PROTECTION (CONCRETE SEALER) 2. LIVE LOAD 100 PSF ITEMS. VERIFY AND CO-ORDINATE ALL FRAMES, OPENINGS, ETC, WITH THE MECHANICAL AND CONSTRUCTED STEEPER THAN 2,5 H I 1 V. ELECTRICAL CONTRACTORS. D1 CONCRETE SEALER SHALL BE APPLIED TO ALL SLABS ON GRADE AND SUPPORTED ASSUMED REACTION FROM STRINGER BEAM (OF STAIRCASE) AS BELOW 1,6 CONTRACTOR SHALL CC -ORDINATE WITH THE QUALIFIED AGENCY RETAINED BY THE OWNER, TO 4 - CONCRETE SURFACES AND EXTENDED 24' UP VERTICAL SURFACES. PERFORM INSPECTION AND TESTING, INSPECTIONS REQUIRED INCLUDE, BUT MAY NOT BE LIMITED 1. DEAD LOAD 2200 LB TWO No. TO I 4A ALL DESIGN AND CONSTRUCTION SHALL BE IN ACCORDANCE WITH ACI 318, AND ACI GUIDE 3362, 5- STRUCTURAL STEEL 2. LIVE LOAD 2200 LB TWO No, REFER TO SPECIFICATIONS 03300, CAST IN PLACE CONCRETE, FOR INFORMATION NOT LISTED HERE IN. - SOILS AND FOUNDATIONS 5.1 DESIGN AND CONSTRUCTION STD-AMERICAN INSTITUTE OF STEEL CONSTRUCTION, INCASE OF CHANGE IN LOADING PER MANUFACTURER BEAM SIZES NEEDS REVESIONS BY eor, - CONCRETE - STRUCTURAL STEEL 4,2 CONCRETE MANUAL OF STEEL CONSTRUCTION LATEST EDITION REFER - MASONRY TO SPECIFICATION SECTION 05120 'STRUCTURAL STEEL' FOR INFORMATION NOT ALL STEEL STAIRS AND HANDRAILS SHALL BE DESIGNED AND CONSTRUCTED BY STAIR MANUFACTURER. - LIGHT GAGE METAL FRAMING A PROVIDE CONCRETE HAVING FOLLOWING GENERAL CHARACTERISTICS LISTED HEREIN, MANUFACTURER SHALL SUBMIT SHOP DRAWINGS AND CALCULATIONS SIGNED AND SEALED BY A LICENSED PROFESSIONAL ENGINEER IN THE state that the project is located, SHOP DRAWINGS SHALL INCLUDE CONNECTION 1.7 ABBREVIATIONS ADD'L=ADDITIONAL FT=FOOT T/BEAM=TOP OF BEAM ARCT=ARCHITECTURAL GA=GUAGE T/FTG=TOP OF FOOTING BOT=BOTTOM GALV=GALVANIZED T/GB=TOP OF GRADE BEAM BRG=BEARING GC=GENERAL CONTRACTOR T/W=TOP OF WALL CJ=CONSTRUCTION JOINT JT=JOINT TYP=TYPICAL DESCRIPTION AS PER ASTM A39 MAX. AGG. SIZE INCH MAX. W/C RATIO AVERAGE ENTRAINED AIR FOOTING, SLAB ON GRADE 3000(UNO ON PLANS) 1 0.40 6.5% FRAMED FLOORS 4000 1/2 0.40 6.5% WALLS 4000 1 0.40 6.57 5.2 ALL WELDING SHALL BE MADE WITH E70XX LOW HYDROGEN ELECTRODE AND DETAILS. CONTRACTOR TO SUBMIT SHOP DRAWINGS & CALCULATIONS TO eor (PRIOR TO CONSTRUCTION) SHALL CONFIRM TO THE LATEST EDITION OF THE AMERICAN WELDING SOCIETY FOR REVIEW & APPROVAL. SPECIFICATIONS, ALL WELDS SHALL BE PERFORMED BY AN AWS CERTIFIED WELDER, 5.3 NO SPLICES IN COLUMNS OR BEAMS WILL BE PERMITTED UNLESS SPECIFICALLY 1 0.0 MASONRY NOTED ON DRAWINGS Masonry Shall be Constructed of Grande N, Type II Units, Laid up in Running Bond. Mortar Shall be Type M or S And Shall Attain a Minimum Compressive Strength of 2,000psi at 28 Days. Strength Shall be Verified CL=CLEAR MAS=MASONRY UN=UNLESS NOTED 5.4 STEEL CONSTRUCTION SHALL BE IN ACCORDANCE WITH FBC-LATEST EDITION AND SHALL CONFORM WITH THE AISC MANUAL STRUCTURAL STEEL SHALL CONFORM TO THE FOLLOWING ASTM STANDARDS I by Prism Testing, Masonry and walls adjacent to cathedral or vaulted ceilings Must extend to the roof, COL=COLUMN MAX=MAXIMUM UNO=UNLESS NOTED OTHERWISE B AVERAGE AIR ENTRAINMENT VALUES ARE FOR IN PLACE CONCRETE, TOLERANCE ON TOTAL AIR Unless Otherwise Noted, Reinforce With #5 Rebar at Each Corner And at 8 Feet Minimum Spacing. Rebar CON( -CONCRETE MIN=MINIMUM CONTENT IS 1.5: PER ACI. W8 AND SMALLER BEAMS A36 Shall Extend From Footing to Lintel And Hooked at Each End, Horizontal Reinforcement, Such as DuroWall, CONN=CONNECTION DET=DETAIL NSNS=NON-SHRINK NON-STAINW/-WITH CC=ON CENTER VIF=VERIFY IN FIELD OTHER BEAMS AND COLUMNS A572-GR 50 Shall be Used at 16' Vertical Spacing. Fill All Cells Containing Reinforcement or Embedded Items, Provide Clean EA=EACH REINF=REINFORCING WWF=WELDED WIRE FABRIC C ALL NORMAL WEIGHT CONCRETE TO HAVE A MINIMUM DENSITY OF 145 PCF UNLESS NOTED, STEEL PLATES, CHANNELS AND ANGLES � A36 Out Holes at Bottom of All Cells Containing Reinforcement, EC -EPDXY COATED REQ'D=REQUIRED ZRC=ZINC RICH COATING LBS OF CEMENT MINIMUM PER CUBIC YARD OF STRUCTURAL PIPES A53 OR A501 Anchor Chimney at Each Floor And Roof, Unless Otherwise Specified, Anchoragge Shall Consist of Two 1/4'X2' EL=ELEVATICN SECT=SECTION (E) =EXISTING D ALL AIR -ENTRAINED CONCRETE SHALL INCLUDE 564 STRUCTURAL TUBES A500-GR B Steel Straps Cast at Least 12' Into Each Face of The ChImrey With a 180 Ilegree Bend and a 6' Extension SIM=SIMILAR (N) = NEW CONCRETE, THE WEIGHT OF FLY ASH AND SILICA FUME ADMIXTURES MAY NOT BE INCLUDED IN ANCHOR BOLTS I A3C7 Around The Vertical Reinforcing Bars in The Outer Face of The Chimney. Each Strap Shall be Fastened to SDG=SLAB ON GRADE WEIGHT OF CEMENT HIGH - STRENGTH BOLTS A325 The Joist or Blocking With a Minimum of 2 ea. 112' Bolts, SPEC=SPECIFICATION HEADED STUDS A108 E FOR THE SITE WORK CONCRETE REFER TO CIVIL DRAWINGS AND SPECIFICATION SECTION 02514 2 •CONSTRUCTION PORTLAND CEMENT CONCRETE 5.5 BOLTED CONNECTIONS TO USE A325-TYPE N, HIGH STRENGTH BOLTS IN BEARING TYPE CONNECTIONS ROOFING TIGHTENED TO A SNUG TIGHT CONDITION IN ACCORDANCE WITH RCSC SPECIFICATIONS, ROOFING MUST BE STRONG ENOUGH TO STAY INTACT IN THE ESTIMATED HIGHEST WINDS OF THE AREA BY 21 GENERAL 4.3 CEMENT THE MANUFACTURE'S INSTALLATION INSTRUCTIONS AND TEST DATA THAT PROVES THE STRENGTH OF THE SHINGLE. A ASTM C 150 TYPE I DR III 5,6 BOLTS IN MOMENT CONNECTIONS AND WIND RESISTING FRAMES SHALL BE ASTM A325-TYPE SC A TAKE EXTREME CAUTION NOT TO DAMAGE IN ANY WAY THE EXISTING ELECTRICAL SERVICE, (SLIP CRITICAL). SLIP CRITICAL CONNECTIONS SHALL HAVE CONTACT SURFACES MEETING CLASS A INSPECTIONS INSPECTIONS SHALL BE MADE ACCORDING TO THE PROVISIONS AND GUIDLINES OF THE FBC 2004 TELECOMMUNICATION LINES, COMPUTER LINES ETC. LOCATE AND MARK ALL SERVICE LINES. B ASTM C595 SURFACE CONDITIONS, BOLTS SHALL BE TENSIONED. SECTION 109 B CONTRACTOR SHALL SHIELD OR TEMPORARILY RELOCATE EXISTING POWER LINES AS REQUIRED 4A AGGREGATE 53 SHOP CONNECTIONS TO BE WELDED OR BOLTED, FIELD CONNECTIONS TO BE BOLTED UNLESS OTHERWISE FOUNDATION INSPECTION: A FOUNDATION SURVEY SHALL BE PERFORMED AND A COPY OF THE DURING CONSTRUCTION SHOWN. BOLT HOLES TO BE STANDARD ROUND HOLES (d+1/16') UNLESS OTHERWISE NOTED. SHORT SURVEY SHALL BE ON THE SITE FOR THE BUILDING INSPECTOR'S USE OR ALL PROPERTY MARKERS A ASTM C 33 SLOTS SHALL BE PERMITTED NORMAL TO THE LOAD DIRECTION IN SLIP CRITICAL AND BEARING TYPE SHALL BE EXPOSED AND A STRING STRETCHED FROM MARKER TO MARKER TO VERIFY REQUIRED CONNECTIONS AS PER AISC REQIREMENTS SETBACKS. ALL WORK SHALL COMPLY WITH PREVAILING CODES. LOCAL BUILDING 6 ALUMINUM. 5.8 MINIMUM BEAM -WEB CONNECTIONS FOR SHEAR AT EACH END SHALL BE DETAILED TO SUPPORT THE LOADS OR PROVIDE THE FOLLOWING MINIMUM NUMBER OF BOLTS WHICHEVER IS GREATER. W8 OR W10 - 2 BOLTS W12 OR W14 - 4 BOLTS ISTRUCTURAL NOTES SCALE: -- 5 4 NnIed i' ScP 201'. 2'R,`M Description : 120 MPH Anal IcalVaiues _ _ _--V ------ - Calculations per ASCE 7-05 ------- ----- ----- ----- -- ---------- -- --- --- :Basic Wind Speed per Sect 6.5.4 &Figure 1 120.0 mph Roof Slope Angle 10 degrees Occupancy per Table 1-1 11 All Buildings and other structures except those listed as Category I, Ill, and IV Importance Factor per Sect. 6.5.5, & Table 6-1 1.00 Exposure Category per 6.5.6.1.4 & .5 Exposure B Mean Roof height 20.0 It Lambda: per Figure 6.2.. Pg 40 1.00 Effective Wind Area of Component & Cladding 10.0 ftA2 Net design pressure from table 1609.9.2.1(2)&(3) interpolated by area Roof pitch for cladding pressure 0 to 7 degrees User specified minimum design pressure 10.0 psf Topographic Factor Kzt per 6.5.7.2 1.00 Design Wind Pressures Minimum Additional Load Case per 6.4.2.1 A = 10 PSF on entire vertical plane Horizontal Pressures ... Zone: A = 25.80 psf Zone: C = 17.10 psi Zone: B = -10.70 psf Zone: 0 = -10.00 psf Vertical Pressures ... Zone: E = -27.40 psf Zone: G = -19,10 psf Zone: F = -16.80 psf Zone: H = -12.90 psf Overhangs... Zone: Eon = -38.40 psf Zone: Goh = -30.10 psf CompOnertt & Cladding Desi n Wind Pressures _. _........ ..... ____----__-... Minimum Additional Load Case per 6.4.2.1 A = 10 PSF on entire vertical plane _ _ ....__ . _ ._.._ ..._...__.....__.. _... - _.__-- -------- Design Wind Pressure = Lambda' Kzt' ImportancePS30 per ASCE 7-05 6.4.2.1 Eq 6-1 Roof Zone 1 : Positive: 10.500 psf Negative: -25.900 psf Roof Zone 2: Positive: 10.500 psf Negative: -43.5W psf Roof Zone 3: Positive: 10.500 psf Negative: -65.400 psf Wall Zone 4: Positive : 25,900 psf Negative: -28.100 psf Wall Zone 5: Positive: 25.900 psf Negative: -34.700 psf Roof Overhang Zone 2: -25,900 psf Roof Overhang Zone 3: -42.700 psf 2 WIND LOAD DATA SCALE: -- 3 ADDITIONAL NOTES SCALE: -- 3 W C F E F C H RADIANT ZH IMPACT CG 12-016 �r< CONNELLY GROUP CONSULTING ENGINEERS ? 200 2nd Ave South - #455 - St Petereburg, FL 33701 'f infoaconnellyengineering.com [T)813.232.8448 [1`)800.6913. 1945 cal www.connellyengineering.com FBC 2007REV09. CHAPTER I PROJECT $.1..4 105 4.1 PERMIT INTENT MI ISSU DATA SHALL BE CONSTRUCTED TO BE A LICENSE TO PROCEED WITH THE WORK AND NOT AS AUTHORITY TO VIOLATE, CANCEL. ALTER OR SET DESIGNER K, WITHSOFTHETECHNICALCODES.NORSHALL ISSUANCE i.a OF A PERMIT PREVENT THE BUILDING OFFICIAL FROM THEREAFTER REQUIRING A CORRECTION OF ERRORS IN PLANS. CONSTRUCTION OR VIOIATIONS OF THIS CODE. EVERY PERMIT ISSUED SHALL BECOME INVALID CRC i UNLESS THE WORK AUTHORRED BY SUCH PERMIT IS COMMENCED WITHIN SIX MONTHS AFTER ITS ISSUANCE. OR IF THE WORK AUTHORIZED BY SUCH PERMIT IS SUSPENDED OR ABANDONED FOR A PERIOD OF SIX MONTHS AFTER THE TIME DRAWN BY JJC THE WORK IS COMMENCED. CHECKED C WE HEREBYCERTIFY THAT THESE PLANS AND SPECIFICATIONS COMPLY WITN THE REQUIREMENTS OF THE APPLICABLE BUILDING CODES SPECIFIED ON THE TITLE SHEET CRC cr, AOL N NORTH CV L0 M M � LL IL w > L.1. j V Z W m .__! V Q J 2 J Q �_: Q LJ. Q i ` Q Q N -.0 N DRAWING SETS PERMIT 01,25.12 C) PROFESSIONAL SEAL DATE SEALED: 25-JAN-1 2 z �. `,t1,,;z1111f1/ ♦,,fit' i�l : � " I � �� OF 11€ lL :.\��•• i ap CL ?0 C BAR R. CON t STRUCTUI` AM' F_ TES WIND LOAD DATA IM S000 10 9 ,11 FA 2 PIII I I I I 10 I 9 I 8 1 7 I 6 1 5 I 4 1 3 1 2 I 1 A B C D E F G H PURPOSE OF REPAIR NOTE: THE FOLLOWING DETAILS AND SPECIFICATIONS SHALL CONSTITUTE A STRUCTURAL REPAIR OF THE EXISTING STRUCTURES WALL ELEMENTS CAUSED BY VEHICLE IMPACT. DETAILS AND SPECIFICATIONS PRESENTED IN THESE DRAWINGS SHALL INCLUDE NECESSARY REPAIR DETAILS AND SPECIFICATIONS TO RETURN THE EXISTING STRUCTURE TO A STATE AS WAS FOUND PRIOR TO THE DAMAGE. DETAILS AND SPECIFICATIONS ARE INTENDED TO REPAIR STRUCTURAL DAMAGE CAUSED BY THE A IMPACT AND ARE NOT INTENDED TO RETURN STRUCTURE TO 'LIKE NEW' CONDITION, PORTIONS OF THE STRUCTURE MAY BE REMOVED AND REPLACED WITH ALTERNATIVE MATERIALS. OUR INTENTION IS TO MAINTAIN THE INTEGRITY AND APPEARANCE OF THE ORIGINAL STRUCTURE WITH MINIMAL INTRUSION AND MODIFICATION TO THE REMAINING STRUCTURAL FRAMING. NOTE: MAIN WALL AND ROOF FRAMING AND FOUNDATION UPGRADES ARE EXCLUDED FROM THIS SCOPE OF WORK. WE ARE ASSUMING THE EXISTING STRUCTURE IS CAPABLE OF SUPPORTING THE CURRENT LOADING IMPOSED ON IT. v THE REMOVAL AND REPLACEMENT OF THE DAMAGED FRAMING AND SUBSEQUENT FINISHES FALLS BELOW THE STANDARD FEMA GUIDELINE AS REFERENCED IN FEMA SCHEDULES PUBLICATION 55 FOR SUBSTANTIAL IMPROVEMENT AND THEREFORE DOES NOT CONSTITUTE A NECESSARY UPGRADE OF THE EXISTING STRUCTURAL ELEMENTS OF SCALE: - AS BUILDING. ALL REPAIRS SHALL BE MADE IN ACCORDANCE WITH THE GUIDELINES AS SPECIFIED IN THE FLORIDA BUILDING CODE (CURRENT EDITION). WITH REVISIONS EXISTING BUILDINGS AND ALL APPLICABLE LOCAL CODES. THE ENGINEER SHALL BE IMMEDIATELY NOTIFIED. IN WRITING. OF ANY ITEMS ANY ITEMS FOUND TO BE DAMAGED OR IMPROPERLY REMOVED DURING THE BUILDING MODIFICATION. ALL TEMPORARY o a EXISTING ROOF JOISTS ---- SUPPORTING ELEMENTS SHALL BE EQUAL OR GREATER IN STRUCTURAL CAPACITY TO `®v TO REMAIN \� THE ITEM BEING REMOVED. O B RECONSTRUCTION NOTES: El I. CONTRACTOR SHALL NOTIFY ENGINEER OF RECORD (EOR) OF DISCREPANCIES OR ANOMALIES FOUND IN THE FIELD. 2. REPAIR DAMAGED WALLS ACCORDING TO REPAIR DETAILS PROVIDED IN THESE PLANS. ALTERNATIVE METHODS WILL NOT BE APPROVED UNLESS AUTHORIZED BY TIE IN NEW MASONRY TO ADJACENT INTERIOR THE FOR IN WRITING PRIOR TO THE REPAIR BEING PERFOMRED. EXISTING FILLED CELLS OF UNDAMAGED MASONRY NO WORK EXISTING FRAMING --� ABOVE TO REMAIN UN AMAGNRY O ' �� REPAIR NOTES REMAIN :. NOTE: ALL DIMENSIONS SHALL i.. EXISTING 2 PLY LVL —FASTEN TRACK TO WOOD BE FIELD VERIFIED BY ALL (TOTAL WIDTH 3.5") BEAM WITH (2) #8 COATED O PROVIDE TEMPORARY SHORING OF ROOF FRAMING AND WALL ELEMENTS PRIOR TO . . REMOVAL AND INSTALLATION OF NEW WALL FRAMING. ALL SHORING INSTALLATION AND 2 TRADES WIT OUT EXCE PTIO WOOD SCREWS AT 8" C/C DESIGN SHALL BE BY OTHERS. FOR RESERVES THE RIGHT TO INSPECT SHORING MIN 2.25" EMBED PRIOR TO START OF REPAIR. INSUFFICIENT SHORING SHALL BE REMOVED AND SI00 ✓ REPLACED OR MODIFIED AS NECESSARY TO PROVIDE ADEQUATE SUPPORT AND I EXISTING STEEL BEAM. STABILITY DURING REPAIR. 3 PLYWOOD SHEATHING AND C 100 ::) j VERTICAL FRMAING OF MAIN REMOVE DAMAGED BLOCK WALL TO UNDERSIDE OF TIE BEAM. INSTALL NEW MASONRY % STRUCTURE TO REMAIN O WALL AND EPDXY ALL REINFORCING STEEL INTO SLAB BELOW. PROVIDE NEW STOREFRONT FRAMING AND INSTALL PER MFG SPECIFICATIONS NEW STOREFRONT—\ );• FRAMING I._. CHECKOUT II .... STATION ALL DAMAGED AND DETERIORATED MORTAR JOINTS SHALL BE NOTED AND MADE 600S162-33 C� Ib C/C VERT O KNOWN. IN WRITING. TO THE FOR FOR REPAIR AND/OR REPLACEMENT AS NECESSARY. ' q 600T162-33 TRACK TOP AND I • `{ EXISTING OR NEW FILLED - f:: ' BOTTOM CONNECT TO STUD \ CELL IN SILL COURSE L_ ` WITH (2) #10 PAN HEAD SDS BELOW STOREFRONT 3 FRAMING ) EACH SIDE, TYPICAL ` TIE IN NEW MASONRY TO ). ' \ / EXISTING FILLED CELLS OF t.. s 600TI500-33 ATTACHMENT TRACK. UNDAMAGED MASONRY �\ FASTEN TRACK TO PLYWOOD SHEATHING AND VERTICAL STUDS WITH (4) 1.5" LONG I_. 5 F. s100 \ 20 #12-14 HWH SDS 0 16" C/C. SCREW UNDAMAGED + \\ MASONRY TO STOREFRONT HEAD HT SHALL PENETRATE PLYWOOD INTO EACH VERTICAL METAL STUD. D REMAIN •10.00' (MOL) AFF. FIELD VERIFY ADD NEW I-#5 IN FULLY —� GROUTED CELLS AS SHOWN. f/ ❑ 600SI62-33 KICKER TO DECK Ccb 32" C/C. FILL TWO CELLS AT END TIE IN TO EXISTING / GLASS WALL 0 INTERIOR FASTENED --- � (EVERY OTHER VERT) CONNECT TO SHADING DENOTES AREA / TO TRACK. INSTALL PER MFG SPECS VERT WITH MIN (5) #10 PAN HEAD SIDS OF IMPACT DAMAGE REPAIR --- ADD WOOD FILLER AS NEEDED FOR ATTACHMENT. _ USE PT WOOD ONLY 3 NEW HEADER AND STOREFRONT ATTACHMENT REPAIR NOTES SCALE: 3A" - 1'-0" SCALE: - NEW STOREFRONT GLASS.—� E MATCH ADJACENT EXISTING PER OWNERS SPECS STOREFRONT SILL HT PRE -CAST CONCRETE----,, -03.50' (MOL) AFF, FIELD VERIFY SILL WITH MIN 35' SLOPE ~\ /—KO BLOCK WITH I-#5 CONS IN FILLED COURSE. PROVIDE STD #5 VERTICAL HOOK BAR TIED TO STUCCO BANDING----�ttow- EACH VERTICAL DOWEL. LAP 3/4" "V" REVEAL, 2" MIN 48 BARD. _ FRY-REGLET INTERIOR STEEL STUD FURRING 4" CHANNELS AND WALL L E INSULATION TO MATCH TO B U ? ' EXISTING, SEE PLAN FOR LOCATION 5/8" PAINTED STUCCO 1/2" GWB OVER MASONRY �\ IMPACT DAMAGE REPAIR AREA � F SCALE:" FINISHES TO MATCH EXISTING. EXIST 8" CMU WALL. SEE PLAN - EXISTING OR NEW FILLED ---- 12" LONG #5 BAR C� 24" C/C CELL, EPDXY NEW #5 r— PROVIDE NEW VERTICAL 5 0 32" INTO FILLED CELL j' VERT, EMBED 6" MIN C/C IF NONE FOUND OR IF EXISTING IS DAMAGED. 7 5/8"' EXISTING CMU ----=� NEW CMU WALL. FILL --DRILL 3/4" 0 X 6" DEEP HOLE. CELL W/ 1-#5 VERT BLOW OUT HOLE AND FILL WITH HALF CELL REPAIR SIMPSON EPDXY -TIE, OR EQUAL G IF CELL IS FULL. EPDXY \ — 12- LONG #5 BAR C� 24" C/C NEW #5 INTO FILLED CELL \ VERT, EMBED b" MIN ASPHALT APRON 7 5/8" NEW CMU WALL. FILL EXISTING CMU ----� 2 CELLS W/ 1-#5 IN EACH ___ EXISTING SLAB AND FOUNDATION H MASONRY DETAILS _ - L NEW SILL DETAIL 5 SCALE: 3" - 1'-0" SCALE: 3" - I'-0" o SCALE: 1.5" - -0- 1 10 I 9 I 8 I 7 1 6 I 5 I 4 I 3 I 2 1 1 1 FBC-APPROVED PRODUCTS LIST -OTHER * SEE ALSO SCHEDULES FOR ADDITIONAL INFORMATION (WHERE APPLICABLE) PRODUCT SUB CATEGORY MANUFACTURER ST. OF FLORIDA APPROVAL NO. WINDOWS EXTERIOR WINDOWS -STOREFRONTS KAWNEER FL7237-R3 RADIANT ZH IMPACT CG 12-016 C❑NNELLY GROUP CONSULTING ENGI NEERB ' 200 2nd Ave South - #465 St Petersburg, FL 33701 info®connsllyengineering.com (T)813. 232. 8448 (F)BOO.69B. 1945 0i WWW.connellyengineering.DDR, F8C 200IREV09. CHAPTER PROJECT { s 108.4.I PERMIT INTENT I i U H LL BE CONSTRUCTED TO BE A LICENSE TO PROCEED DATA WITH THE WORK AND NOT AS AUTHORITY TO VIOLATE. CANCEL ALTER OR SET ASIDE ANY OF THE PROVISIONS OF THE TECHNICAL CODES, NOR SMALL ISSUANCE OF A PERMIT PREVENT THE BUILDING OFFICIAL FROM THEREAFTER DESIGNER E REQUIRING A CORRECTION OF ERRORS IN PLANS, CONSTRUCTION OR VIOLATIONS OF THIS CODE EVERY PERMIT ISSUED SHALL BECOME INVALID CRC DRAWN BY JJC L.I,? f.l�rt UNLESS THE WORK AUTHORZED BY SUCH PERMIT IS COMMENCED WITHIN 51X MONTHS AFTER ITS IS SUANCE. OR IF THE WORK AUTHORIZED BY SUCH PERMIT IS SUSPENDED OR ABANDONED FOR A PERIOD OF SIX MONTHS AFTER THE TIME THE WORK IS COMMENCED. CHECKED CRC ,M. Yam• WE HEREBY CERTIFY THAT THESE PLANS AND SPECIFICATIONS COMPLY WITH THE REQUIREMENTS OF THE APPLICABLE BUILDING CODES SPECIFIED ON THE TITLE SHEET LcJ NORTH CV 0 M-7 0 M � J LL LL J J w MJ 0CIO W J Q - EJ = �. Q Q Q Q a N EL cr. UI W .o N DRAWING SETS PERMIT 01.25.12 PROFESSIONAL SEAL DATE SEALED: 25-UAN-1 2 r^ •v r �. y RI m_� " ��.gqCOO 'uno$11``�� '� " STRUCTURAL DETAILS sloo