Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
7715 (7707-7731) Gall Blvd
PROPOSED TENANT BUILD -OUT FOR: C�1 0 ZEPHYRHILLS, SYMBOLS LEGEND DETAIL CALLOUT REFERENCE DETAIL NUMBER AREAINCULUDED IN DETAIL SHEET NUMBER ON WHICH DETAIL IS LOCATED DIRECTION OF CUT DETAIL NUMBER 1 � A101 SHEET NUMBER ON WHICH DETAIL SECTION CUT IS LOCATED REFERENCE SITE PLAN NOTE NUMBER (SEE KEYNOTE LEGEND - SAME SHEET) 10 POINTS TO LOCATION AFFECTED BY NOTE KEYED NOTE DETAIL NUMBER 1 View Name A101 SCALE: 1/8" = V-0" DETAIL SCALE SHEET NUMBER ON WHICH DETAIL IS LOCATED DETAIL IDENTIFICATION . � n W1 T7 I cl9 15 PROJECT INFORMATION PROJECT NAME ASPEN DENTAL PROJECT ADDRESS ZEPHYRHILLS SUPERCENTER 7707-7731 GALL BLVD., STE: A-2 ZEPHERHILLS, FL 33540 PROJECT USE DENTAL OFFICE BUISNESS (B) APPLICABLE CODES 2007 FLORIDA BUILDING CODE -BUILDING W/ LOCAL AMENDMENTS & REVISIONS -EXISTING BUILDING -PLUMBING -MECHANICAL -FUEL GAS -FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION 2005 NATIONAL ELECTRIC CODE 2007 FIRE PREVENTION CODE USE & OCCUPANCY CLASSIFICATION OCCUPANCY CLASSIFICATION BUISNESS GROUP B BUILDING SIZE PROPOSED TENANT IMPROVMENT 3,493 S.F. TYPE OF CONSTRUCTION TYPE OF CONSTRUCTION TYPE V -UNPROTECTED INTERIOR FINISHES WALLS & CEILINGS INTERIOR WALL & CEILING FINISH CLASS - "B" FIRE PROTECTION SYSTEMS OCCUPANCY SEPERATION MULTI -TENANT BUILDING FIRE BARRIER FIRE RESISTANCE RATING - 1 HRS AUTOMATIC SPRINKLER SYSTEM FIRE ALARM & DETECTION SYSTEM NO FIRE ALARM & DETECTION: YES MEANS OF EGRESS OCCUPANT LOADS ROOM OR CLASSIFICATION FLOOR DENSITY OCCUPANT OCCUPANT OCCUPANT ROOM OR OCCUPANTS SPACE OCCUPANCY AREA SF/PERSON LOAD BY LOAD BY LOAD BY SPACE ACCOUNTED FOR DESIGNATION FOR USE (S.F.) CALCULATION ACTUAL NO. COMBINATION TOTAL IN OTHER SPACES 1ST FLOOR BUISNESS 3,493 100 GROSS 35 - - 35 EXIT DISTANCE 200' EXIT DISTANCE ACCESSIBILITY EXIT WIDTH REQUIRED: 7" PROVIDED: 72" COMMON PATH OF TRAVEL NO. OF EXITS 75' TRAVEL DISTANCE 2 EXITS ACCESSIBLE ENTRANCES ACCESSIBLE EXITS 1 2 PLUMBING FIXTURE COUNT SANITARY FIXTURES OCCUPANCY WATER CLOSETS LAVATORIES DRINK FOUNTAINS SERVICE SINK TYPE CAPACITY FACTORS # M. FIX. # F. FIX. FACTORS # FIX. FACTORS # FIX. FACTORS # FIX. B - GROUP 35 PERSONS 1/25 1/40 1/100 1 1 (BUISNESS) .7 .7 .85 .35 PROVIDED 1WC 1 WC 2 2 1 FIXTURES pRniFrT CC)KITACTr% PLAN REVIEW / INSPECTION CITY OF ZEPHYRHILLS BUILDING DEPT. 5335 8TH STREET ZEPHYRHILLS, FL 33542 PHONE: (813) 780-0020 FAX: (813) 780-0021 LANDLORD FRONTIER DEVELOPMENT 10 S. NEW RIVER DR. STE: 104 FORT LAUDERDALE, FL 33301 OWNER / CONNT. MANAGER ASPEN DENTAL MANAGEMENT CONTACT: SHAWN CHRISTOPHER 281 SANDERS CREEK PARKWAY EAST SYRACUSE, NEW YORK 13507 PHONE: (315) 454-6000 x261 FAX: (315) 454-6324 MEP EXCEL ENGINEERING INC. CONTACT: RAY DEL PONTE OR KURT BARNARD 100 CAMELOT DRIVE FOND DU LAC, WI 54935 PHONE: (920) 926-9800 FAX: (920) 926-9801 ARCHITECTURAL EXCEL ENGINEERING INC. CONTACT: ADAM HEINDEL OR JAY JOHNSON 100 CAMELOT DRIVE FOND DU LAC, WI 54935 PHONE: (920) 926-9800 FAX: (920) 926-9801 SUBMPITED PLt BY ZEPH M' Date: Reviewer: — .10 tit FLORIDA SHEET INDEX SHEET SHEET TITLE o �W W CO �� L) o Q � Ww W2 z p =ppJ �U))m z O u� > Of z O U) > O O o Of W U) >z �O DATE: 11/19/2009 11/23/2009 - - T1.0 TITLE SHEET, BUILDING DATA, LOCATION MAP, SITE PLAN PRELIM X YES T2.0 GENERAL NOTES / SPECIFICATIONS PRELIM X YES T2.1 GENERAL NOTES / SPECIFICATIONS PRELIM X YES ARCHITECTURAL SHEETS D1.1 DEMOLITION FLOOR PLAN PRELIM X YES A1.1 FLOOR PLAN, DOOR SCHEDULE, & DETAILS PRELIM X YES A1.2 ROOF PLAN & DETAILS PRELIM X YES A2.0 BUILDING ELEVATION PRELIM X YES A4.0 WALL SECTIONS & DETAILS PRELIM X YES A5.0 ENLARGED TOILET ROOM PLANS, INT. ELEVATIONS & DETAILS PRELIM X YES A5.1 GENERAL ACCISSIBILITY NOTES & DETAILS PRELIM X YES A6.1 ROOM FINISH PLAN & SCHEDULE PRELIM X YES A7.1 REFLECTED CEILING PLAN & DETAILS PRELIM X YES DENTAL EQUIPMENT SUPPLIED SHEETS MD MEDICAL EQUIPMENT DETAILS PRELIM X YES ELECTRICAL SHEETS ED1.1 DEMOLITION PLAN PRELIM X I YES E0.1 LEGEND, ONE LINE DIAGRAM, & SCHEDULES PRELIM X YES E0.2 SPECIFICATIONS & DETAILS PRELIM X YES E1.1 L FLOOR PLAN - LIGHTING PRELIM X YES E1.1 P FLOOR PLAN - POWER PRELIM X YES HVAC SHEETS HD1.1 HO.1 DEMOLITION PLAN SCHEDULES & SPECIFICATIONS PRELIM PRELIM X X YES YES H1.1 FLOOR PLAN, LEGEND, DETAILS, & NOTES PRELIM X YES PLUMBING SHEETS P0.1 LEGEND, SPECIFICATIONS, & GENERAL SCHEDULES PRELIM X YES PD1.1 PARTIAL UNDERGROUND AND FLOOR PLANS - DEMOLITION PRELIM X YES P1.0 UN GROUND PLAN PRELIM X YES ),HA N PRELIM X YES PLAN - AIR & VACUUM PIPING PRELIM X YES SOMETRICS & SCHEDULES PRELIM X YES DETAILS PRELIM X YES Loll SCHEDULES PRELIM X YES SHEET INDEX LEGEND FbM be advised l4view of cursory review to assist the contralWi #� with WkIpAle fire safety codes. This review is not intended to be a final approval of the submitted plans. It is the c OntracWs sole responsibility to ensure that the plans are in complete compliance with all applicable NFPA codes and local ordinances, in the event that further examination or site inspection revels areas of nOn-compliance, it shall be the contractor's sot' r'sp0nsb1ity, at tt>leir sole expense to bring those areas in compliance. The City assumes no responsibility for the contractor's failure to be in WNW with all applicable NFPA Codes and local ordinfces. WTIL.OING SHALL ;0 1gI.Y w ALL APPLICABLE BUILDING, ELEC'I"RICAI., PLLUBILNG AW REVIEW DATE: / � � CITY OF ZEPHYYtHIL BUILDING OFFICIAL C( LOCATION MAP A s P a n DD R TC, a 100 CAMELOT DRIVE FOND DU LAC, WI 54935 PHONE: (920) 926-98W FAX: (920) 926-9801 Always a Better Plan 0 Q� z � � LJ � Q O W a_ 0 Q > Z Q Li W W Z U L Q U) =) z w U Q N. �— LLI Q (n z Z W V) �- C U) U� 00 Q O Q N Lw 0 N W ~ z Q O � W U J LO LLI m M J J J J Q Li Q CD zJ J U �, L, Q = = � z � 0 w = _ 0- (/) a_ LJ O I-, EL Li CL a N I- N SHEET ISSUE: NOVEMBER 23, 2009 SEE TITLE SHEET TO CONFIM THAT THIS SHEET HAS BEEN ISSUED FOR CONSTRUCTION REVISIONS: DATE: NOV. 231 2009 z JOB NUMBER: c� 914790 Li z CD SHEET w J w U T1.0 rn ��j 0 LANDLORD WORK LETTER EXHIBIT B ASPEN DENTAL -VANILLA SHELL REQUIREMENTS 1. FLOOR SLAB AND FINISH: A SMOOTH AND LEVEL CONCRETE FLOOR SLAB, FREE OF LEVELING PRODUCTS, WITH NOT MORE THAN ONE -EIGHTH INCH (118) VARIATION IN TEN FEET (10) AND ALL REQUIRED EXPANSION AND CONTROL JOINTS PROPERLY INSTALLED AND READY FOR TENANT -SPECIFIED FLOOR COVERINGS. ON GRADE FLOORS WILL HAVE A FUNCTIONING VAPOR RETARDER BENEATH THE SLAB. 2. DEMISING WALLS: ANY INTERIOR WALL SEPARATING THE PREMISES FROM OTHER SPACE (DEMISING WALLS) SHALL BE CONSTRUCTED WITH METAL STUDS COVERED WITH DRYWALL ON BOTH SIDES, TAPED AND SANDED (READY TO PAINT), AND SHALL HAVE A MINIMUM ONE (1) HOUR FIRE RATING OR SUCH RATING AS IS REQUIRED PER APPLICABLE BUILDING CODES. LANDLORD SHALL PROVIDE DEMISING WALLS TO THE FULL HEIGHT OF THE ROOF DECK. INTERIOR SURFACES OF ALL WALLS IN THE PREMISES SHALL BE FURNISHED WITH FIVE -EIGHTS INCH (5/8) GYPSUM WALLBOARD, TAPED, SANDED SMOOTH, AND PAINTED PER TENANTS PLANS AND SPECIFICATIONS. ALL CUTTING AND PATCHING SHALL BE COMPLETED BY LANDLORD PER TENANTS PLANS AND SPECIFICATIONS. DEMISING WALL SHALL INCLUDE 6 BATT INSULATION FOR SOUND ABSORBSION 3. INTERIOR OF PERIMETER WALLS: THE INTERIOR OF PERIMETER WALLS SHALL BE CONSTRUCTED OR FURRED WITH 2" HAT CHANNEL OR 2" X 4" STUDS, INSULATED AS REQUIRED BY APPLICABLE BUILDING CODES), WITH VAPOR BARRIER INSTALLED. INTERIOR SURFACES OF ALL WALLS IN THE PREMISES SHALL BE FINISHED WITH FIVE -EIGHTS INCH (5/8) GYPSUM WALLBOARD, TAPED AND SANDED SMOOTH TO A HEIGHT OF 12' AFF OR GREATER IF REQUIRED BY APPLICABLE BUILDING CODES. 4. STOREFRONT/DOORS/IMNDOWS: A. STOREFRONT WINDOW FRAMES: STOREFRONT TO BE PROVIDED BY LANDLORD AND SHALL INCLUDE A MINIMUM WINDOW FRAME HEIGHT OF TEN FEET (10) ABOVE FINISH FLOOR. DOOR LOCATION TO BE APPROVED BY TENANT. THE STOREFRONT SHALL INCLUDE ALL STOREFRONT STRUCTURAL COMPONENTS, WITH ALL COLUMNS AND VOIDS, COMPLETED AND CLAD WITH STOREFRONT METAL. B. DOORS: NARROW STYLE 250 A.D.A. APPROVED SINGLE ACTING, FULLY WEATHER-STRIPPED, SURFACE APPLIED, LCN 4041 OR APPROVED CLOSERS, ONE-HALF INCH ('/z) MAXIMUM THRESHOLD, TYPE B PUSH/PULL HARDWARE PAIRS 3070 WITH TRANSOM, AND ONE -QUARTER INCH (1/4) CLEAR TEMPERED DOOR GLASS. C. GLASS: PER LANDLORD'S APPROVED PLAN (EXISTING) D. SECONDARY EXIT/SERVICE DOOR: DOOR SHALL BE MINIMUM T-0" WIDE & OPEN DIRECTLY TO THE EXTERIOR OR TO A HANDICAP ACCESSIBLE EXIT CORRIDOR WITH KEYED PANIC HARDWARE INSTALLED PER LOCAL BUILDING CODES AND ORDINANCES. THE LOCATION OF THE SECONDARY EXIT/SERVICE DOOR SHALL BE APPROVED BY TENANT. 5. AIR-CONDITIONING AND HEATING: A. LANDLORD SHALL SUPPLY, INSTALL, DISTRIBUTE DUCT WORK FOR, BALANCE, AND START UP A NEW HEATING AND AIR-CONDITIONING UNIT/S. THE HVAC SYSTEM SHALL BE DESIGNED BY LANDLORD AND SHALL INCLUDE A DUCTED RETURN SYSTEM. THE DESIGN/LAYOUT IS TO CONFORM TO TENANTS FLOOR PLAN. FINAL DESIGN TO BE APPROVED BY TENANT. THE NEW UNITS TO BE SIZED 1 TON PER 300 SQUARE FEET. LANDLORD SHALL SUPPLY (3) THREE NEW SEPARATE PACKAGED ROOF TOP UNITS (RTUS). ONE UNIT IS TO BE DESIGNATED SOLELY FOR THE TENANTS RECEPTION AREA AND THE OTHER TWO UNITS TO BE DESIGNATED FOR THE REMAINDER OF THE OFFICE/SPACE. THE THERMOSTAT IN THE RECEPTION AREA SHALL HAVE A LOCKBOX. THE LOCKBOX KEYS MUST BE GIVEN TO ASPEN DENTAL MANAGEMENT UPON JOB COMPLETION. B. IF SMOKE DETECTORS ARE REQUIRED TO BE INSTALLED IN THE RETURN AIR DUCT BY APPLICABLE BUILDING CODE, THEN LANDLORD WILL INSTALL A VISIBLE AND AUDIBLE SMOKE DETECTOR IN THE RETURN AIR DUCT OF THE HVAC UNIT. LANDLORD SHALL SUPPLY THERMOSTATS PER TENANTS PLANS. C. LANDLORD SHALL PROVIDE TRANSFERABLE WARRANTIES ON THE CARRIER/YORK/ TRANE HEATING AND AIR-CONDITIONING SYSTEM(S). COMPRESSORS SHALL HAVE A FIVE (5) YEAR WARRANTY. THE SYSTEM AND OTHER COMPONENTS SHALL HAVE THE MANUFACTURERS STANDARD PERIOD WARRANTY, BUT IN NO EVENT LESS THAN TWELVE (12) MONTHS. D. THE HVAC UNIT CAPACITY SHALL MAINTAIN TEMPERATURE AT NOT MORE THAN SEVENTY-TWO DEGREES FAHRENHEIT (72°F) IN COOLING MODE (SUMMER) AND NOT LESS THAN SIXTY-EIGHT DEGREES FAHRENHEIT (68°F) IN HEATING MODE (WINTER). DESIGN CRITERIA FOR MECHANICAL SYSTEMS TO INCLUDE GLASS AREA AND EXPOSURE, CUSTOMER AND EMPLOYEE LOAD, LIGHTING LOAD OF THREE (3) WATTS PER SQUARE FOOT, COMPUTER AND RELATED LOAD FACTORS (PER APPLICABLE BUILDING CODES). (72°F) IN COOLING MODE IN THE OCCUPIED SETTING. LANDLORD SHALL SUPPLY THERMOSTATS PER TENANTS PLANS. E. THE SYSTEM SHALL BE COMPLETE AND FULLY FUNCTIONING AND TESTED FOR HEATING AND COOLING MODE UPON DELIVERY OF POSSESSION OF THE PREMISES TO TENANT. LANDLORD SHALL BE RESPONSIBLE FOR THE INITIAL START-UP, INSTALLATION OF NEW FILTERS PRIOR TO OPENING, TEST AND BALANCE OF THE SYSTEM. F. LANDLORD SHALL INSTALL RESTROOM EXHAUST FLUES AND REQUIRED ROOF PENETRATION/S IN ACCORDANCE WITH APPLICABLE BUILDING CODES. LANDLORD SHALL ALSO PROVIDE FRESH AIR INTAKES (ECONOMIZERS) AS REQUIRED FOR RTUS. G. THE HVAC DUCT WORK SHALL BE GALVANIZED, UNPAINTED DUCTING. HVAC DUCT WORK WILL BE INSTALLED TWELVE FEET (12) MINIMUM ABOVE FINISH FLOOR AND SHALL BE INSULATED PER INDUSTRY STANDARDS. 6. RESTROOMS & PLUMBING: LANDLORD SHALL PROVIDE AS FOLLOWS: A. RESTROOMS: LANDLORD SHALL PROVIDE TWO (2) ADA COMPLIANT RESTROOMS WITH COMMON TOILET FACILITIES FOR MEN AND WOMEN. THE RESTROOMS SHALL BE LOCATED AS PER TENANTS PLANS AND SPECIFICATIONS. RESTROOMS WILL INCLUDE THE FOLLOWING: WALLS: 5/8" GYPSUM WALL BOARD, WATER RESISTANT, TAPED AND SANDED AS PER TENANTS PLANS AND SPECIFICATIONS; RESTROOM CEILING: PER TENANTS PLANS AND SPECIFICATIONS; AS PER EXISTING. 1 - T-0" X 6'-8" SOLID CORE BIRCH DOOR (UNFINISHED) WITH LOCKSET (PER TENANTS PLANS AND SPECIFICATIONS) WITH METAL FRAME; HARDWARE SHALL BE: RHOADS LEVER TYPE LOCKSET OR EQUAL WITH BRUSHED ALUMINUM FINISH. 1 - WALL -HUNG LAVATORY WITH 24" X 36" MIRROR, OR AS MANY AS REQUIRED BY CODE 1 - WATER CLOSET OR AS MANY AS REQUIRED BY CODE PER TENANTS SPEC; 1 - 40-GALLON WATER HEATER, OR AS PER CODE, LOCATED IN TENANTS MECHANICAL ROOM WIRED AND PLUMBED FOR USE. (A.O. SMITH OR EQUAL) 1 - CEILING -MOUNTED FAN WITH TOGGLE SWITCH; NOT LESS THAN 75CFM PER FAN. 1 - WALL RECEPTACLE (GFI); 1 - TOILET PAPER HOLDER - BRADLEY 5071-S0 OR EQUAL; 1 - DRINKING FOUNTAIN, IF REQUIRED BY CODE, LOCATED PER TENANTS PLANS- ELKAY - EDFPW- 114-C, SINGLE LEVEL, WHEEL CHAIR ACCESS DRINKING FOUNTAIN WITH WALL PLATE AND PUSH-BUTTON BUBBLER (LK-142) OR EQUAL OR AS REQUIRED BY APPLICABLE BUILDING CODES; 1 ONE (1) FLOOR DRAIN PER RESTROOM WITH TRAP PRIMER. B. FIRE SPRINKLER AND ALARM SYSTEM: A FIRE SPRINKLER SYSTEM & FIRE ALARM SYSTEM, IF REQUIRED BY GOVERNING AGENCIES, WILL BE SUPPLIED AND INSTALLED AT LANDLORDS SOLE COST AND EXPENSE. LANDLORD WILL BE RESPONSIBLE FOR ALL DESIGN DRAWINGS FOR BOTH THE FIRE ALARM AND FIRE SPRINKLER SYSTEM. IF SUCH SYSTEM IS REQUIRED, LANDLORD SHALL INSTALL IN ACCORDANCE WITH APPLICABLE BUILDING CODES. LANDLORD SHALL SUPPLY LINES, VALVES, DROPS, AND PENDANT STYLE HEADS AS REQUIRED BY APPLICABLE BUILDING CODES AND PER TENANTS FLOOR PLAN. LANDLORD SHALL ALSO PROVIDE A BACKFLOW PREVENTER IF REQUIRED BY APPLICABLE BUILDING CODES. MONITORING DEVICES, ALARMS, PULLS, ENUNCIATOR PANELS, VISUAL AND AUDIO WARNING INDICATORS, STROBES, AND ANY OTHER REQUIRED MATERIALS, SYSTEM TESTING, INSPECTION APPROVAL BY THE LOCAL FIRE INSPECTOR AND MONTHLY MONITORING AND ALARM FEES INCLUDING TELEPHONE LINES, IF REQUIRED, ARE THE RESPONSIBILITY OF THE LANDLORD DURING THE LEASE TERM. THE FIRE RISER SHALL BE IN A LOCATION APPROVED BY TENANT. LANDLORD WILL BE RESPONSIBLE FOR ANY MONTHLY MONITORING AND ASSOCIATED FEES IN CONNECTION WITH THE OPERATION OF THE SYSTEM DURING THE LEASE TERM. FIRE ALARM SYSTEM TO BE INSTALLED PER TENANTS FLOOR PLAN OR AS REQUIRED BY APPLICABLE BUILDING CODES. 7. ELECTRICAL: A. LANDLORD SHALL PROVIDE AND INSTALL A DEDICATED ELECTRICAL SERVICE WITH A MINIMUM OF TWO HUNDRED (200) AMPS VOLTAGE TO BE 120/208, 3-PHASE, 4-WIRE. ELECTRICAL SERVICE TO BE INSTALLED IN TENANTS MECHANICAL ROOM. B. LANDLORD SHALL PROVIDE AND INSTALL A METER FOR THE ELECTRICAL SERVICE DEDICATED SOLELY TO TENANT IN ACCORDANCE WITH METERING REQUIREMENTS OF THE UTILITY COMPANY. LANDLORD SHALL INSTALL THE METER IN A LOCATION ACCEPTABLE TO LOCAL UTILITY COMPANY AND TENANT. LANDLORD SHALL BE RESPONSIBLE FOR ALL INSTALLATION RELATED METER FEES. C. LANDLORD TO PROVIDE AND INSTALL A 200 AMP 1201208 3-PHASE ELECTRICAL SERVICE WITH MAIN DISCONNECT USING SQUARE D PANELS, ONE (1) 225 AMP 42 SPACE PANEL WITH MAIN DISCONNECT AND (1)100 AMP 24 SPACE SUB PANEL INSIDE TENANTS MECHANICAL ROOM INCLUDING ALL SQUARE D BREAKERS. CONDUIT AND WIRE SIZES PER NATIONAL ELECTRICAL CODE. ALL WIRE AND BUS SHALL BE COPPER. ALL PANELS SHALL BE LOCATED IN ACCORDANCE WITH TENANTS PLANS. FINAL LOCATION MUST BE VERIFIED WITH TENANT PRIOR TO INSTALLATION. D. LIFE SAFETY SYSTEMS (I.E. SMOKE ALARMS AND FIRE DETECTION SYSTEMS) ARE ALSO THE RESPONSIBILITY OF THE LANDLORD, IF REQUIRED BY CODE. LANDLORD WILL BE RESPONSIBLE FOR ANY MONTHLY MONITORING AND ASSOCIATED FEES DURING THE LEASE TERM. E. LANDLORD SHALL PROVIDE EXIT SIGNS & EMERGENCY LIGHTS AS REQUIRED BY APPLICABLE BUILDING CODES. F. LANDLORD SHALL PROVIDE AND INSTALL 2'X2' & 2'X4' LAY -IN LIGHT FIXTURES WITH ACRYLIC LENSES TO CURRENT CODE BASED ON 1 FIXTURE PER 60 SF IN ACCORDANCE WITH TENANTS FLOOR PLAN. LIGHTING SPECIFICATION WILL BE A COMBINATION OF 2,3 & FOUR LAMP FIXTURES WITH ELECTRONIC BALLASTS AND SHALL BE LIGHTOLIER OR EQUAL. ALL SWITCHING SHALL BE PER TENANTS FLOOR PLAN. G. LANDLORD SHALL INSTALL ONE HUNDRED TWENTY (120) VOLT DUPLEX OUTLETS PER LOCAL BUILDING CODES AROUND THE PERIMETER EXTERIOR WALLS OF THE DEMISED PREMISES. H. LANDLORD SHALL PROVIDE A MINIMUM OF ONE (1) ONE HUNDRED TWENTY (120) VOLT DUPLEX OUTLET WITH GROUND FAULT INTERRUPTER (GFI) IN EACH RESTROOM AT LOCATIONS PER TENANTS PLANS AND SPECIFICATIONS AND LOCAL BUILDING CODES. 1. LANDLORD SHALL PROVIDE POWER FOR EXTERIOR SIGNAGE AS REQUIRED PER TENANTS SPECIFIED LOCATIONS AND POWER REQUIREMENTS. LANDLORD IS TO PROVIDE A TIME CLOCKS FOR THE EXTERIOR SIGNAGE INSTALLED NEXT TO THE ELECTRICAL PANELS IN THE TENANTS MECHANICAL ROOM. J. LANDLORD SHALL PROVIDE ONE (1) ONE HUNDRED TWENTY (120) VOLT QUADPLEX OUTLET NEXT TO ELECTRICAL PANEL FOR TENANTS PHONE SYSTEM PER EXISTING LOCATION. K. LANDLORD SHALL FURNISH AND INSTALL A TWO INCH (2) CONDUIT LABELED FOR CABLE TV COMPANY USE ONLY FROM TENANTS MECHANICAL ROOM TO THE NEAREST UTILITY POLE ON SITE. 8. CEILING: SUSPENDED ACOUSTICAL 2' X 4' CEILING TILE AND GRID SYSTEM WITH ARMSTRONG SECOND LOOK #2767 INSTALLED PER TENANTS FLOOR PLAN. CEILINGS WILL BE INSTALLED AFTER THE INTERIOR WALLS ARE FRAMED. 9. UTILITIES: LANDLORD TO PROVIDE ELECTRICAL, GAS A 100 POUND PROPANE GAS TANK (TO BE INSTALLED AT THE BACK OF THE BUILDING / PLAZA) ANDAND WATER SERVICE TO THE PREMISES AND PAY ALL CONNECTION AND HOOKUP FEES ASSOCIATED. WATER SERVICE TO BE 1 MINIMUM. GAS TO BE SIZED PER TENANT LOAD REQUIREMENTS. ELECTRICAL PER SECTION 10 ABOVE. ALL ACCOUNTS ARE TO BE SET UP IN LANDLORDS NAME AND WILL BE TRANSFERRED TO TENANT UPON DELIVERY OF THE SPACE. 10. OTHER: A. LEASE SPACE SHALL HAVE NO HAZARDOUS MATERIALS IN ANY FORM, INCLUDING, BUT NOT LIMITED TO ASBESTOS, ASBESTOS PRODUCTS, POLYCHLORINATED BIPHENYL (PCB) OR OTHER TOXIC SUBSTANCES. B. LEASE SPACE SHALL BE CLEARED OF ANY STORED MATERIALS, FIXTURES, FURNITURE, MILLWORK OR EQUIPMENT. C. PATH FROM PARKING AREA TO FRONT DOOR SHALL BE HANDICAP ACCESSIBLE. D. VANILLA SHELL SHALL MEET ALL LOCAL BUILDING CODES, ADA REQUIREMENTS, AND ZONING ORDINANCES. E. ROOFING SYSTEM ABOVE LEASE SPACE SHALL BE WATERTIGHT AND UNDER WARRANTEE. THE COST OF ALL REQUIRED REPAIRS TO MAINTAIN THE ROOFING SYSTEM IN A WATERTIGHT CONDITION, AND ANY ASSOCIATED LOSS BY TENANT, SHALL BE PAID BY THE LANDLORD. F. PARKING LOT WILL BE STRIPED, ADEQUATE HANDICAP PARKING AND IN GOOD REPAIR. SCOPE OF WORK GENERAL NOTES: 1. ALL WORK SHALL BE DONE IN STRICT ACCORDANCE WITH ALL APPLICABLE LOCAL, STATE AND FEDERAL BUILDING CODES AND/OR REGULATIONS. 2. ALL WORK SHALL BE DONE IN A MANNER CONSISTENT WITH THE HIGHEST STANDARDS OF THE RESPECTIVE TRADES. 3. THE CONTRACTOR SHALL VISIT THE SITE AND FAMILARIZE HIMSELF WITH THE EXISTING CONDITIONS BEFORE BIDDING. 4. THE CONTRACTOR SHALL VERIFY ALL FIELD DIMENSIONS BEFORE PROCEEDING WITH THE WORK. IN THE EVENT OF A DISCREPANCY, THE CONTRACTOR SHALL NOTIFY ASPEN DENTAL MANGMENT INCORPORATED (ADMI) IMMEDIATELY. 5. THE CONTRACTOR SHALL ABIDE BY ALL REQUIREMENTS OF THE OWNER WITH RESPECT TO CONSTRUCTION SCHEDULING, COORDINATION, TEMPORARY CONSTRUCTION UTILITIES, ECT. 6. ALL MATERIALS, PRODUCTS AND UNITS SHALL BE INSTALLED PER MANUFACTURERS RECOMMENDATIONS AND INSTRUCTIONS. ASPEN DENTAL SHALL BE NOTIFICED IMMEDIATELY OF ANY DISCREPANCIES. 7. INSTALLATION OF ALL MATERIALS AND/OR UNITS TO BE SELECTED BY, SUPPLIED BY, AND/OR INSTALLED BY THE OWNER SHALL BE SCHEDULED AND COORDINATED BY THE CONTRACTOR TO MAINTAIN THE CONSTRUCTION SCHEDULE. PRIOR TO THE COMMENCEMENT OF THE WORK, THE CONTRACTOR SHALL NOTIFY THE OWNER OF ALL QUANTITIES OF OWNER SUPPLIES MATERIALS AND/OR UNITS NOT SPECIFICALLY CALLED OUT IN THESE CONSTRUCTION DOCUMENTS. THE CONTRACTOR SHALL NOTIFY THE OWNER OF REQUIRED DELIVERY DATES OF OWNER SUPPLIED MATERIALS AND UNITS. 8. ALL FINISH PAINT SHALL BE APPLIED OVER A COMPATIBLE FACTORY OR FIELD APPLIED PRIMER. 9. THE CONTRACTOR SHALL PROTECT ALL EXISTING AND ADJACENT AREAS AT ALL TIMES DURING CONSTRUCTION. ANY AREA DAMAGES OR AFFECTED BY CONSTRUCTION SHALL BE PATCHED, REPAIRED, OR REPLACED AS REQUIRED TO MATCH EXISTING OR ADJACENT AREAS AT THE CONTRACTORS EXPENSE. 10. THE CONTRACTOR SHALL YIELD TO THE OWNER AND THEIR VISITORS AT ALL TIMES. 11. THE CONTRACTOR SHALL NOT DISRUPT THE BUILDING OR OPERATIONS WITHOUT PRIOR SCHEDULING AND APPROVAL FROM THE OWNER/LANDLORD. 12. THE ARCHITECT ASSUMES NO RESPONSIBILITY FOR ANY DEVIATION FROM THE FINAL CONSTRUCTION DOCUMENTS, NO MATTER WHAT THE CAUSE, UNLESS A WRITTEN DIRECTIVE IS GIVEN BY THE ARCHITECT. 13. IF CONFLICT OCCURS ON THESE CONSTRUCION DOCUMENTS AND/OR THE SPECIFICATIONS, THE CONTRACTOR SHALL BID THE HIGHER QUALITY AND/OR QUANTITY. THE CONTRACTOR SHALL ALSO CONTACT ASPEN DENTAL FOR CLARIFICATION BEFORE SUBMITTING HIS BID. 14. ALL WORK THAT IS EITHER IMPLIED OR REASONABLY INFERRED BY THE CONTRACT DOCUMENTS, DRAWINGS AND SPECIFICATIONS SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. 15. ALL WORK PERFORMED SHALL INCLUDE ALL APPURTENANCES AND APPARATUS NORMALLY DEEMED TO BE PART OF A COMPLETE PACKAGE WITHIN THE DEFINITIONS OF NORMAL INDUSTRY STANDARDS. 16. ALL DIMENSIONS ARE CLEAR (FINISH TO FINISH). ALL FINAL DIMENSIONS AND LAYOUT SHALL BE VERIFIED WITH AND APPROVED BY THE OWNER AS REQUIRED BEFORE PROCEEDING WITH THE WORK. 17. ALL PERMITS, INSPECTIONS AND APPROVALS SHALL BE SECURED BY THE CONTRACTOR. 18. ALL PROJECTIONS THROUGH THE ROOF SHALL BE FLASHED AND COUNTER -FLASHED AS REQUIRED. ROOF WORK SHALL BE PERFORMED BY LANDLORDS ROOFING CONTRACTOR AT TENTANTS COST. 19. THE CONTRACTOR SHALL PROVIDE ALL MISCELLANEOUS BLOCKING AND BRACING AS REQUIRED. 20. THE ARCHITECT ASSUMES NO RESPONSIBILITY FOR CONSTRUCTION MEANS, METHODS, MATERIALS, TECHNIQUES, PROCEDURES, SEQUENCES OR SCHEDULING IN CONNECTIONS WITH THE WORK. 21. IN THE EVENT OF NOTE DIRECTION OR MATERIAL SPECIFICATION CONFLICT IN THESE DOCUMENTS, CONTACT ASPEN DENTAL. 22. THE CONTRACTOR SHALL REMOVE ALL RUBBISH AND WASTE MATERIAL ON A DAILY BASIS AND KEEP THE JOB SITE AND ALL EGRESS EXIT PATHWAYS BROOM CLEAN AT ALL TIMES. ALL WASTE MATERIAL SHALL BE DISPOSED OF PROPERLY. NOTE: INFORMATION CONCERNING EXISTING BUILDING CONDITIONS WAS OBTAINED FROM VARIOUS CONSTRUCTION DOCUMENTS AND FROM FIELD OBSERVATIONS. EVERY EFFORT HAS BEEN MADE TO ACCURATELY DEPICT EXISTING CONDITIONS. HOWEVER, ALL WORK MUST BE FIELD VERIFIED PRIOR TO CONSTRUCTION, AND ANY CONFLICT BETWEEN THESE DOCUMENTS AND ACTUAL FIELD CONDITIONS SHALL BE REPORTED IMMEDIATELY TO ASPEN DENTAL FOR VERIFICATION AND/OR CORRECTION. THE ARCHITECT ASSUMES NO RESPONSIBILTY FOR ANY WORK WHICH DEVIATES FROM THE FINAL CONSTRUCTION DOCUMENTS, NO MATTER WHAT THE CAUSE, UNLESS A WRITTEN DIRECTIVE IS ISSUED BY THE ARCHITECT PRIOR TO CONSTRUCTION OR INSTALLATION OF THE WORK. PROJECT NOTES SUBMITTAL AND FEES Nlp `a • THIS SUBMITTAL IS FOR THIS TENANT SPACE BUILD -OUT ONLY. ADDITIONAL TENANT SPACES WILL BE SUBMITTED SEPARATELY, GENERAL PERMITTING & BUILDING PERMIT ASSOCIAED. IF CONTRACTOR EXCEL DEVIATES FROM PLAN OR PREVIOUS PERMIT SUBMITTAL DOCUMENTS, W/O WRITTEN CONSENT FROM THE ARCHITECT / ASPEN DENTAL, THE E NG 1 N E E R[ N G CONTRACTOR WILL BE HELD LIABLE FOR CHANGES MADE, AND Inc REQUIRED TO RESUBMIT FOR APPROVAL. CONTRACTOR/ SUB -CONTRACTOR NOTE 100 CAMELOT DRIVE FOND DU LAC, WI 5493S • ALL TRADES SHALL CROSS REFERENCE ALL CONSTRUCTION PHONE: (920) 926-98MFAX: DOCUMENTS FOR COORDINATION AND SCOPE OF WORK. (920) 926-9801 SHOP DRAWINGS • ALL TRADES SHALL SUBMIT SHOP DRAWINGS PRIOR TO ORDERING, Always a Better Plan INSTALLING, OR FABRICATION IS PERFORMED. ALLOW ENOUGH TIME FOR SUBMITTAL REVIEW, INCLUDING TIME FOR RESUBMITTALS, AS�����������������\��\\\\\\OO FOLLOWS. TIME FOR REVIEW SHALL COMMENCE ON ASPEN DENTAL'S RECEIPT OF SUBMITTAL (10 DAYS MIN.). NO EXTENSION OF THE CONTRACT TIME WILL BE AUTHORIZED BECAUSE OF FAILURE TO TRANSMIT SUBMITTALS ENOUGH IN ADVANCE OF THE WORK TO PERMIT PROCESSING, INCLUDING RESUBMITTALS. ANY SUBSTITUTION FROM PLANS OR SPEC'S SHALL BE WRITTEN IN AT TIME OF BID. SUBSTITUTION L0 OF MATERIALS FROM ORIGINAL PLANS OR SPEC'S MAY REQUIRE O ADDITIONAL REVIEW FOR COMPLIANCE. THESE COSTS WILL BE PAST DIRECTLY ON TO THE GENERAL CONTRACTOR AT EXCEL'S TIME AND MATERIALS. Q z CLOSE-OUT / O&M MANUALS • CONTRACTORS SHALL PROVIDE CLOSE-OUT / O&M MANUALS FOR W 0 INSTALLED EQUIPMENT AND SHALL SHOW TENANT AND OWNER W < >_ REPRESENTATIVE NECESSARY OPERATION AND MAINTENANCE � INFORMATION. PROVIDE 3 COPIES OF EACH. Q AS -BUILT DRAWINGS LLI Q w z • CONTRACTORS SHALL PROVIDE CLEAN & LEGIBLE AS -BUILT DRAWINGS 0:� AT COMPLETION OF PROJECT. PROVIDE 2 COPIES TO OWNER. THIS U W APPLIES TO ALL SUBS AND TRADES DOING WORK ON THE SITE. J (n GENERAL CONTR. ALSO RESPONSIBLE TO AS -BUILT ANY WORK FROM Q i) D ANY UTILITY CONTR. (IE: WE ENERGIES, WPS, AT&T, ETC.) z � U PROJECT FINAL PAYMENT LLJ z • GENERAL CONTRACTOR TO PROVIDE ALL THE ABOVE LISTED ITEMS AS W Q PART OF THE PROJECT CLOSE-OUT PACKAGE. THIS INFORMATION TO BE Z PROVIDED TO THE OWNER PRIOR TO RECEIVING FINAL PAY DRAW ON Z LLJ THE COMPLETED PROJECT. n cn MEP AND FIRE PROTECTION NOTES V) 00 Q Q N W O . INFORMATION SHOWN ON THESE DRAWINGS FOR (PLUMBING, HVAC, ELECTRICAL AND FIRE PROTECTION) IS FOR GENERAL DESIGN INTENT/ BIDDING & INSTALLATION PURPOSES ONLY. • ALL CONTRACTORS TO COMPLY W/ ALL LOCAL/STATE CODES & ORDINANCES. . ALL CONTRACTORS ARE RESPONSIBLE FOR ALL FEES/ PERMITS ASSOCIATED WITH THESE TRADES FOR COMPLETION OF WORK OUTLINED. • G.C. TO PROVIDE KNOX BOX (WHERE APPLICABLE) -COORDINATE LOCATION Q W/ FIRE DEPARTMENT N W I- W cn z Q 0 d" W U Q Lo ry W m � :D J J J J C/) Q U W J J ry z ry I >- 0 W = _ W W O a_ ry U) W I-, W CL Q N I__ N SHEET ISSUE: NOVEMBER 23, 2009 SEE TITLE SHEET TO CONFIM THAT THIS SHEET HAS BEEN ISSUED FOR CONSTRUCTION REVISIONS: DATE: NOV. 23, 2009 z JOB NUMBER: 914790 Li Z�\\oo\o\\00000�000��o�oo��oo��\�oo��o CD SHEET W Li zoo @ W U 00 T2.0 As"I". 3. Xi >0 ' 0 D a SPECIFICATIONS I. GENERAL REQUIREMENTS ti A. THE PLANS AND SPECIFICATIONS ARE INTENDED TO GIVE A DESCRIPTION OF THE WORK. NO DEVIATION FROM THE PLANS AND SPECIFICATIONS SHALL BE MADE WITHOUT THE WRITTEN CONSENT OF EXCEL ENGINEERING, INC. THE CONTRACTOR IS TO CLARIFY .ANY DISCREPANCIES WITH EXCEL ENGINEERING, INC. PRIOR TO BEGINNING WORK. THE CONTRACTOR SHALL VISIT THE SITE TO VERIFY EXISTING CONDITIONS AND ACCESS TO THE WORK AREA. B. THE CONTRACTOR HAS THE SOLE RESPONSIBILITY FOR AND SHALL HAVE CONTROL OF CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, AND SAFETY PRECAUTIONS AND PROCEDURES USED TO CONSTRUCT THE WORK. C. THE CONTRACTOR SHALL FURNISH ALL LABOR, MATERIAL (INCLUDING TAXES) AND EQUIPMENT AS NECESSARY TO COMPLETE THE WORK. PERMITS SHALL BE OBTAINED AND PAID FOR BY THE RESPECTIVE CONTRACTOR, INCLUDING TEMPORARY OCCUPANCY PERMIT IF REQUIRED. D. THE CONTRACTOR SHALL FURNISH TEMPORARY BRACING OF ALL BUILDING ELEMENTS DURING CONSTRUCTION. TEMPORARY BRACING SYSTEMS SHALL BE DESIGNED TO WITHSTAND CODE DESIGN LOADS. CONTRACTOR SHALL RETAIN SERVICES OF A PROFESSIONAL ENGINEER TO DESIGN AND SUPERVISE BRACING INSTALLATION IF THEY DO NOT HAVE THE EXPERTISE REQUIRED. E. ALL APPLICABLE FEDERAL, STATE, AND LOCAL CODES, ORDINANCES AND REGULATIONS, INCLUDING THE REQUIREMENTS OF THE AMERIC AN WITH DISABILITIES ACT (A.D.A.) ARE MADE PART OF THESE SPECIFICATIONS AND SHALL BE COMPLIED WITH AS FAR AS THEY APPLY TO WORK UNDER THIS CONTRACT. F. IN AS MUCH AS THE SPECIFICATIONS ARE BRIEF, THE CONTRACTOR SHALL PROVIDE WORKMANSHIP THAT IS NEAT, SECURE AND OF THE BEST QUALITY WITH THE BEST POSSIBLE APPEARANCE AND UTILITY. FAULTY WORK SHALL BE REPAIRED OR REPLACED AT NO COST TO THE OWNER. INDUSTRY STANDARDS SHALL BE USED AS THE GUIDE FOR QUALITY OF MATERIALS AND WORKMANSHIP. G. REFERENCE TO MATERIALS OR SYSTEMS HEREIN BY NAME, MAKE OR CATALOG NUMBER IS INTENDED TO ESTABLISH A QUALITY STANDARD, AND NOT TO LIMIT COMPETITION. THE WORDS "OR APPROVED EQUIVALENT" ARE IMPLIED FOLLOWING EACH BRAND NAME/MODEL NUMBER UNLESS STATED OTHERWISE. "OR APPROVED EQUIVALENT" MATERIALS SHALL BE APPROVED BY EXCEL ENGINEERING, INC. PRIOR TO BIDS BEING ACCEPTED AND ACCEPTANCE FOR USE. PROVIDE A LETTER FROM THE MANUFACTURER CERTIFYING THAT THE PRODUCT MEETS OR EXCEEDS THE SPECIFIED PRODUCT. H. SUBMIT FIVE (5) COPIES OF STRUCTURAL (HVAC, PLUMBING, FIRE PROTECTION AND ELECTRICAL IF PART OF THIS PLAN) SHOP DRAWINGS TO EXCEL ENGINEERING, INC. FOR APPROVAL PRIOR TO FABRICATION AND INSTALLATION. SHOP DRAWINGS SHALL BE REVIEWED AND STAMPED BY THE CONTRACTOR PRIOR TO SUBMITTING FOR APPROVAL SHOP DRAWING SUBMITTALS MUST BE 100% COMPLETE AND IN ONE (1) PACKAGE FOR THE ITEM BEING SUBMITTED. NON -COMPLETE SHOP DRAWINGS OR PARTIAL ITEM SHOP DRAWINGS WILL BE RETURNED TO THE CONTRACTOR WITHOUT COMMENT AND STAMPED °REJECTED -RESUBMIT." CONTRACTORS WHO KNOWINGLY WANT TO SUBMIT NON -COMPLETE SHOP DRAWINGS OR BREAK SINGLE ITEM SHOP DRAWINGS INTO MULTIPLE SUBMITTALS WILL BE RESPONSIBLE TO MAKE ARRANGEMENTS WITH EXCEL ENGINEERING, PRIOR TO SUBMITTING THE SHOP DR.AWING(S), TO COMPENSATE EXCEL ENGINEERING FOR THE EXTRA WORK INVOLVED. NON- STRUCTURAL ITEMS AND SAMPLES FOR FINISHES ARE TO BE SUBMITTED TO EXCEL ENGINEERING, INC. FOR APPROVAL PRIOR TO INSTALLATION. I. PRIOR TO COMMENCEMENT OF WORK, THE CONTRACTOR SHALL SUBMIT TO THE OWNER A CERTIFICATE OF INSURANCE FOR NOT LESS THAN THE FOLLOWING LIMITS: 1. WORKER'S COMPENSATION AND EMPLOYERS LIABILITY A. PER STATUTORY LIMITS 2. COMMERCIAL GENERAL LIABILITY A. GENERAL AGGREGATE: $2,000,000 B. PRODUCTS AND COMPLETED OPERATIONS AGGREGATE: $2,000,000 C. PERSONAL AND ADVERTISING INJURY: $1,000,000 D. EACH OCCURRENCE: $1,000,000 3. COMPREHENSIVE AUTOMOBILE LIABILITY A. COMBINED SINGLE LIMIT BODILY INJURY AND PROPERTY DAMAGE: $1,000,000 B. NON -OWNED AND HIRED AUTOMOBILE: $1,000,000 J. THE CONTRACTOR SHALL OBTAIN THE OWNER'S APPROVAL OF THE CONSTRUCTION SCHEDULE PRIOR TO PROCEEDING WITH THE WORK. r K. THE CONTRACTOR SHALL FURNISH TEMPORARY OFFICE, TOILET FACILITIES, WORKING TELEPHONE, ELECTRICITY, HEAT, WATER AND FIRE EXTINGUISHERS AS REQUIRED FOR COMPLETION OF THE WORK UNLESS THE OWNER HAS AGREED IN WRITING TO FURNISH OR WAIVE ANY OF THE ABOVE ITEMS. L. THE CONTRACTOR SHALL PROVIDE ALL LAYOUT AS REQUIRED, COMPETENT ON SITE SUPERVISION, AND BROOM CLEANING OF CONSTRUCTION SITE INCLUDING DUMPSTERS FOR REFUSE DISPOSAL. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SAFETY ON SITE AND PROTECTION OF SITE PER LOCAL, STATE AND FEDERAL REQUIREMENTS. M. NOTIFY ARCHITECT ONE WEEK IN ADVANCE TO SCHEDULE FINAL COMPLIANCE WALK-THRU. PRIOR TO THIS WALK THRU, PROVIDE THE ARCHITECT WITH THE FIRE PROTECTION SYSTEM TEST REPORT AND A COPY OF THE ELEVATOR INSPECTION REPORT AS APPLICABLE. ALL COMPONENT SUBMITTALS SHOULD BE FILED AND AVAILABLE FOR REVIEW AT THE WALK THRU. THE BUILDING SHALL BE COMPLETE AND ALL SYSTEMS OPERATIONAL AT THE TIME OF THE WALK THRU. IF THE ARCHITECT IS REQUIRED TO MAKE ADDITIONAL VISITS DUE TO NON- COMPLIANCE, THEY WILL BE CHARGED TO THE REQUESTING CONTRACTOR. N. THE CONTRACTOR SHALL GUARANTEE ALL WORKMANSHIP AND MATERIALS FOR A PERIOD OF ONE YEAR AFTER SUBSTANTIAL COMPLETION OF THE PROJECT. FURNISH MANUFACTURER'S WRITTEN WARRANTIES FOR SPECIFIED EQUIPMENT STATING EFFECTIVE WARRANTY DATE. 0. THE CONTRACTOR SHALL FURNISH "AS -BUILT" DRAWINGS REFLECTING ALL CHANGES DURING CONSTRUCTION. PROVIDE TWO (2) COPIES OF OPERATING AND MAINTENANCE MANUALS TO OWNER FOR ALL FURNISHED EQUIPMENT. II. CONCRETE A. DESIGN AND CONSTRUCTION OF ALL CAST -IN -PLACE CONCRETE WORK SHALL CONFORM TO ACI 318 BUILDING CODE AND CRSI MANUAL OF STANDARD PRACTICE. B. CONCRETE SLAB CONSTRUCTION TO BE PROVIDED PER MORE STRINGENT REQUIREMENTS OF GEOTECHNICA_ REPORT OR CONSTRUCTION DOCUMENTS. C. DESIGN MIXES SHALL BE IN ACCORDANCE WITH ASTM C94. 1_ STRENGTH TO BE MIN. 3,000 PSI AT 28 DAYS FOR FOOTINGS AND WALLS. 2. STRENGTH TO BE MIN. 3,500 PSI AT 28 DAYS FOR SLABS ON GRADE. 3. STRENGTH TO BE MIN. 4,000 PSI AT 28 DAYS FOR COLUMNS, BEAMS, EXTERIOR CONCRETE, STRUCTURAL SLABS, CONCRETE FILLED METAL DECK AND PRECAST TOPPINGS. 4. SLUMP SHALL NOT EXCEED 4". 5. ALL CONCRETE EXPOSED TO WEATHER SHALL BE AIR -ENTRAINED WITH 4-7% AIR CONTENT. NO OTHER ADMIXTURES SHALL BE USED WITHOUT APPROVAL OF EXCEL ENGINEERING, INC. CALCIUM CHLORIDE SHALL NOT BE USED. 6. MAXIMUM AGGREGATE SIZE FOR FOOTING TO BE 1 1/2" AND MAXIMUM AGGREGATE SIZE FOR ALL OTHER WORK TO BE 3/4" D. PLACE SLABS ON GRADE WITH CONSTRUCTION JOINT OR SAW JOINT AS INDICATED ON THE PLANS. SAW CUT TO BE DONE AS SOON AS POSSIBLE, BUT NO LATER THAN 24 HOURS AFTER CONCRETE IS PLACED. ALL INTERIOR SLABS TO HAVE A TROWEL FINISH AND ALL EXTERIOR SLABS TO HAVE A LIGHT BROOM FINISH UNLESS NOTED OTHERWISE. MAINTAIN FLOOR LEVEL AT WALLS AND PITCH SURFACES UNIFORMLY TO DRAINS. ALL CONCRETE IS TO BE CURED FOR 7 DAYS. FLOORS TO BE STAINED, TO RECEIVE AN ASHFORD SEALER, OR TO RECEIVE ANOTHER FINISH THAT IS NOT COMPATIBLE WITH CURING COMPOUNDS ARE TO BE WET CURED OR CURED WITH AN ARMORLON TRANSGUARD 4000 WET CURE COVER PER MANUFACTURER'S SPECIFICATION. EXTERIOR SLABS SHALL BE SEPARATED FROM BUILDINGS WITH CONTINUOUS 1/2" FIBER EXPANSION JOINT AND/OR 1/4" FIBER EXPANSION JOINT AT DECORATIVE MASONRY UNITS. INTERIOR SLABS SHALL BE SEPARATED FROM FOUNDATION WALLS AND PIERS WITH FORM RELEASE AGENT. 15 LB. FELT OR AS DETAILED ON PLANS. E. THE SLAB -ON -GRADE FLOOR FLATNESS/LEVELNESS SHALL MEET TO THE FOLLOWING CRITERIA: 1. TOP OF FLOOR ELEVATION SHALL BE WITHIN 3/4" OF DESIGN ELEVATION IN ACCORDANCE TO ACI 117 TOLERANCES. 2. THE SPECIFIED OVERALL VALUE FOR THE FLOOR FLATNESS/LEVELNESS IS AS FOLLOWS: A. NONCRITICAL MECHANICAL ROOMS, NONPUBLIC AREAS, AND PARKING - FF20 / FL.15. B. CARPETED AREAS IN COMMERCIAL OFFICE, INDUSTRIAL BUILDING - FF25 / FL20. C. THIN -SET FLOORING, WAREHOUSE - FF35 / FL25. D. WAREHOUSE WITH AIR -PALLET USE, ICE RINKS - FF45 / FL35. E. CRITICAL AREAS AS INDICATED ON PLAN - >FF50 / >FL50. 3. THE MINIMUM LOCAL VALUE FOR THE FLOOR FLATNESS/LEVELNESS SHALL NOT BE LESS THAN 67% OF THE SPECIFIED OVERALL VALUE. 4. CONTRACTOR SHALL REPLACE AREAS THAT DO NOT MEET THESE CRITERIA. F. ALL REINFORCING BARS SHALL BE ASTM A615 GRADE 60. THICKNESS OF CONCRETE COVER OVER REINFORCEMENT SHALL BE NOT LESS THAN 3" WHERE CONCRETE IS DEPOSITED AGAINST THE GROUND WITHOUT THE USE OF FORMS AND NOT LESS THAN 1 1/2" IN ALL OTHER LOCATIONS. ALL REINFORCING SHALL BE LAPPED 36 DIAMETERS FOR UP TO #6 BARS, 60 DIAMETERS FOR #7 TO #10 BARS OR AS NOTED ON THE DRAWINGS AND EXTENDED AROUND CORNERS WITH CORNER BARS. PLACING AND DETAILING OF STEEL REINFORCING AND REINFORCING SUPPORTS SHALL BE IN ACCORDANCE WITH CRSI AND ACI MANUAL AND STANDARD PRACTICES. THE REINFORCEMENT SHALL NOT BE PAINTED AND MUST BE FREE OF GREASE/OIL, DIRT OR DEEP RUST WHEN PLACED IN THE WORK. ALL WELDED WIRE FABRIC SHALL MEET THE REQUIREMENTS OF ASTM A185. WELDED WIRE FABRIC SHALL BE PLACED 2" FROM TOP OF SLAB, UNLESS INDICATED OTHERWISE. G. CONTRACTOR SHALL ENGAGE A QUALIFIED INDEPENDENT TESTING AND INSPECTING AGENCY TO SAMPLE MATERIALS, PERFORM TESTS, AND SUBMIT TEST REPORTS DURING CONCRETE PLACEMENT. TESTS WILL BE PERFORMED ACCORDING TO ACI 301. CAST AND LABORATORY CURE ONE SET OF FOUR STANDARD CYLINDERS FOR EACH COMPOSITE SAMPLE FOR EACH DAY'S POUR OF EACH CONCRETE MIX EXCEEDING 5 CU. YD., BUT LESS THAN 25 -CU. YD., PLUS ONE SET FOR EACH ADDITIONAL 50 CU. YD. OR FRACTION THEREOF. PERFORM COMPRESSIVE - STRENGTH TESTS ACCORDING TO ASTM C 39. TEST TWO SPECIMENS AT 7 DAYS AND TWO SPECIMENS AT 28 DAYS. PERFORM SLUMP TESTING ACCORDING TO ASTM C 143. PROVIDE ONE TEST AT .POINT OF PLACEMENT FOR EACH COMPOSITE SAMPLE, BUT NOT LESS THAN ONE TEST FOR EACH DAY'S POUR OF EACH CONCRETE MIX. PERFORM ADDITIONAL TESTS WHEN CONCRETE CONSISTENCY APPEARS TO CHANGE. H. PROTECT FRESHLY PLACED CONCRETE FROM PREMATURE DRYING AND EXCESSIVE COLD OR HOT TEMPERATURES. IN HOT, DRY, AND WINDY WEATHER, APPLY AN EVAPORATION -CONTROL COMPOUND ACCORDING TO MANUFACTURER'S INSTRUCTIONS AFTER SCREEDING AND BULL FLOATING, BUT BEFORE POWER FLOATING AND TROWELLING. I. LIMIT MAXIMUM WATER-CEMENTITIOUS RATIO OF CONCRETE EXPOSED TO FREEZING, THAWING AND DEICING SALTS TO 0.45. J. APPLY TROWEL FINISH TO MONOLITHIC SLAB SURFACES TO BE EXPOSED TO VIEW AND SLAB SURFACES TO BE COVERED WITH RESILIENT FLOORING, CARPET, PAINT, OR OTHER THIN FILM - FINISH COATING SYSTEM. APPLY NONSLIP BROOM FINISH TO EXTERIOR CONCRETE PLATFORMS, STEPS, AND RAMPS, AND ELSEWHERE AS INDICATED. K. TEST RESULTS WILL BE REPORTED IN WRITING TO ARCHITECT, READY -MIX PRODUCER, AND CONTRACTOR WITHIN 24 HOURS AFTER TESTS. REPORTS OF COMPRESSIVE STRENGTH TESTS SHALL CONTAIN THE PROJECT IDENTIFICATION NAME AND NUMBER, DATE OF CONCRETE PLACEMENT, NAME OF CONCRETE TESTING SERVICE, CONCRETE TYPE AND CLASS, LOCATION OF CONCRETE BATCH IN STRUCTURE, DESIGN COMPRESSIVE STRENGTH AT 28 DAYS, CONCRETE MIX PROPORTIONS AND MATERIALS, COMPRESSIVE BREAKING STRENGTH, AND TYPE OF BREAK FOR BOTH 7-DAY TESTS AND 28-DAY TESTS. 1. INCLUDE THIS SET OF PLANS WITH THE PROJECT AS -BUILT PLANS. III. LUMBER A. LUMBER SHALL BE GRADED AND STAMPED WITH MINIMUM STRUCTURAL DESIGN VALUES AS LISTED BELOW. 1. #1/#2 DOUG FIR 850 PSI FB, 95 PSI FV, 1600 KS! E (BEAMS, LINTELS & HEADERS, UNLESS NOTED) 2. #1/#2 S.P.F. 875 PSI FB, 1150 PSI FC, 1400 KSI E (ALL STUDS & PLATES, UNLESS NOTED) 3. LVL @ 1800 KSI E OR MICRO -LAM @ 1900 KSI E 2600 PSI FB, 285 PSI FV (OR AS NOTED ON THE PLANS) 4. WOOD HEADER MATERIAL SHALL BE FREE OF ALL SPLITS, SHAKES AND CHECKS. B. MISCELLANEOUS LUMBER: PROVIDE NO. 3 OR STANDARD GRADE LUMBER OF ANY SPECIES FOR SUPPORT OR ATTACHMENT OF OTHER CONSTRUCTION, INCLUDING ROOFTOP EQUIPMENT CURBS AND SUPPORT BASES, CANT STRIPS, BUCKS, NAILERS, BLOCKING, AND SIMILAR MEMBERS. C. PROTECTION AGAINST DECAY WITH PRESERVATIVE -TREATED WOOD SHALL BE REQUIRED IN THE FOLLOWING AREAS: 1. ALL WOOD SILL PLATES, FRAMING, AND FURRING STRIPS ATTACHED TO EXTERIOR BELOW GRADE MASONRY AND CONCRETE WALLS. 2. ALL WOOD PLATES, BLOCKING, FRAMING AND FURRING STRIPS ATTACHED TO EXTERIOR, SINGLE-WYTHE MASONRY WALLS. 3. ALL WOOD CAP FLASHING BLOCKING ATTACHED TO MASONRY OR CONCRETE PARAPETS. 4. ALL WOOD SLEEPERS AND SILL PLATES ON CONCRETE SLABS IN DIRECT CONTACT WITH EARTH. A. EXCEPTION: WOOD SILL PLATES ON CONCRETE SLABS SEPARATED FROM DIRECT CONTACT TO THE EARTH WITH A 10 MIL POLYETHYLENE VAPOR RETARDANT WILL NOT REQUIRE PRESERVATIVE -TREATMENT. 5. ALL WOOD IN CONTACT WITH GROUND OR EXPOSED TO THE WEATHER. D. FINISHES FOR FASTENERS AND HARDWARE IN CONTACT WITH PRESERVATIVE -TREATED WOOD ARE BASED ON THE FOLLOWING ASSUMPTIONS: 1. ALL INTERIOR TREATED WOOD SHALL USE AN ACQ-C, ACQ-D (CARBONATE), CBA-A, OR CA-B TREATMENT WITH RETENTION LEVELS LESS THAN OR EQUAL TO 0.40 PCF, 0.40 PCF, 0.41 PCF, AND 0.21 PCF RESPECTIVELY. 2. ALL CONNECTION HARDWARE AND FASTENERS IN DIRECT CONTACT WITH INTERIOR TREATED WOOD SHALL BE HOT -DIPPED GALVANIZED, MECHANICALLY GALVANIZED, OR STAINLESS STEEL. 3. ALL CONNECTION HARDWARE AND FASTENERS IN DIRECT CONTACT WITH EXPOSED EXTERIOR TREATED WOOD OR UNKNOWN TREATMENTS SHALL BE STAINLESS STEEL. 4. USE TAPCON CLIMASEAL FASTENERS TO CONNECT ACQ-TREATED WOOD BLOCKING TO MASONRY OR CONCRETE PARAPETS. E. SHOP DRAWINGS FOR PRESERVATIVE -TREATED WOOD, HARDWARE, AND FASTENERS: 1. THE CONTRACTOR SHALL FURNISH MATERIAL CERTIFICATES FOR ALL PRESERVATIVE - IV. EXTERIORNAME OF THE TREATING COMPANY, THE PRESERVATIVE USED, THE LEVEL OF TREATMENT (0.10, 0.25, 0.40, ETC.), THE INTENDED USE (ABOVE GROUND, GROUND CONTACT, ETC.), AND A REFERENCE TO THE APPROPRIATE AWPA STANDARD, 2. THE CONTRACTOR SHALL FURNISH MATERIAL DA-A SHEETS FOR HARDWARE AND FASTENERS IN CONTACT WITH PRESERVATIVE -TREATED WOOD. A. ALL EIFS MATERIALS AND INSTALLATION SHALL COMPLY WITH LOCAL AND STATE CODES AND TO EIMA GUIDELINE SPECIFICATIONS FOR EXTERIOR INSULATION AND FINISH SYSTEMS, CLASS PB WITH MOISTURE DRAINAGE. B. SUBMIT THE FOLLOWING ITEMS. 1. PRODUCT DATA: PRODUCT DATA SHEETS DESCRIBING PRODUCTS TO BE USED ON PROJEC T. 2. SAMPLES: SAMPLES FOR EACH FINISH, TEXTURE, AND COLOR TO BE USED ON PROJECT. 3. QUALITY ASSURANCE/CONTROL SUBMITTALS: MANUFACTURERS INSTALLATION INSTRUCTIONS. C. FOLLOW MANUFACTURERS INSTRUCTIONS ON PRODUCT STORAGE AND HANDLING. D. STORE MOISTURE SENSITIVE MATERIALS IN WEATHER PROTECTED ENCLOSURES. E. PROVIDE A COMPLETE EXTERIOR INSULATION AND FINISH SYSTEM ,CLASS PB, CONSISTING OF, BUT NOT LIMITED TO, A AIR & MOISTURE BARRIER, AN ADHESIVE, EXPANDED POLYSTYRENE INSULATION BOARD, BASE COAT, REINFORCING MESH(ES)AND FINISH. F. INSTALL EIFS IN ACCORDANCE WITH MANUFACTURERS INSTALLATION INSTRUCTIONS AND AS SHOWN ON PLANS. G. ALL SURROUNDING AREAS, WHERE THE EIFS HAS BEEN INSTALLED, SHALL BE LEFT FREE OF DEBRIS AND FOREIGN SUBSTANCES RESULTING FROM THE WORK. H. PROTECT FINISHED WORK FROM INCLEMENT WEATHER UNTIL DRY AND PERMANENT PROTECTION IN THE FORM OF FLASHINGS, SEALANTS, ETC. ARE INSTALLED. L PROTECT FINISHED WORK FROM DAMAGE DURING REMAINDER OF CONSTRUCTION PERIOD: V. AIR AND MOISTURE A. ALL AIR AND MOISTURE BARRIER MATERIALS AND INSTALLATION SHALL COMPLY WITH LOCAL AND STATE CODES. B. SUBMIT THE FOLLOWING ITEMS. 1. PRODUCT DATA: MANUFACTURERS TECHNICAL BULLETINS. C. FOLLOW MANUFACTURERS INSTRUCTIONS ON PRODUCT STORAGE AND HANDLING. D. STORE MOISTURE SENSITIVE MATERIALS IN WEATHER PROTECTED ENCLOSURES. E. PROVIDE A COMPLETE AIR AND MOISTURE BARRIER SYSTEM USING A FLUID APPLIED THREE- PART SYSTEM. THE SYSTEM CONSISTS OF ADHESIVE MESH TAPE AND LIQUID FILL AND SPRAY WRAP. 1. ACCEPTABLE PRODUCT: PROSOCO R-GUARD OR EQUAL. F. INSTALL AIR AND MOISTURE BARRIER IN ACCORDANCE WITH MANUFACTURERS INSTALLATION INSTRUCTIONS AND AS SHOWN ON PLANS. 1. APPLY R-GUARD TAPE OVER SHEATHING JOINTS AND SEAMS. FOLD AND APPLY R-GUARD TAPE TO ROUGH OPENINGS, INSIDE AND OUTSIDE CORNERS. USE A SEAM ROLLER OR OTHER BLUNT TOOL TO FIRMLY ADHERE TAPE TO SHEATHING. 2. UNIFORMLY COVER TAPE AND ABOUT 4 INCHES OF SHEATHING ON EITHER SIDE OF THE TAPE WITH R-GUARD FILL USING A TROWEL OR TEXTURE SPRAYER. TROWEL SMOOTH. SPOT FILL FASTENERS AND SURFACE DEFECTS WITH R-GUARD FILL. LET DRY. 3. SPRAY OR ROLLER APPLY R-GUARD SPRAY WRAP TO THE ENTIRE SURFACE -INCLUDING AREAS COVERED BY R-GUARD TAPE AND R-GUARD FILL TO A UNIFORM WET MIL THICKNESS (10 MILS). LET DRY. ON MASONRY CONSTRUCTION, WHEN SPRAY APPLYING, B AC KROLL TO CLOSE PINHOLES AND ENSURE EVEN COVERAGE. APPLY NUMBER OF COATS AS REQUIRED BY MANUFACTURERS SPECIFICATIONS. G. ALL SURROUNDING AREAS, WHERE THE AIR AND MOISTURE BARRIER HAS BEEN INSTALLED, SHALL BE LEFT FREE OF DEBRIS AND FOREIGN SUBSTANCES RESULTING FROM THE WORK. H. PROTECT FINISHED WORK FROM DAMAGE DURING REMAINDER OF CONSTRUCTION PERIOD. VI. INSULATION A. ALL INSULATION MATERIALS AND INSTALLATION SHALL COMPLY WITH LOCAL AND STATE CODES. B. PRODUCT: FIBERGLASS INSULATION TO BE FIBERGLASS BATT OR ROLL COMPLYING WITH ASTM C665 AND NONCOMBUSTIBLE PER ASTM E136. THICKNESS OR R VALUE AS INDICATED ON PLANS. IF THICKNESS IS NOT SHOWN ON PLANS, THICKNESS TO BE THE DEPTH OF THE WALL OR RAFTER SYSTEM. 1. MANUFACTURER: CERTAINTEED OR OWENS CORNING. C. PRODUCT: VAPOR RETARDER TO BE MEMBRANE VAPOR RETARDER INSTALLED ON WARM SIDE (NORMALLY INSIDE) FACE OF THE INSULATION. 1. MANUFACTURER: CERTAINTEED. D. PRODUCT: ACOUSTICAL WALL INSULATION TO BE NOISE REDUCER SOUND CONTROL BATTS IN WOOD FRAME CONSTRUCTION. WALL INSULATION TO BE CERT.ASOUND SOUND ATTENUATION BATTS IN METAL FRAMED WALLS AND CEILINGS. ACOUSTICAL CEILING BATTS TO BE CERTASOUND. 1. MANUFACTURER: CERTAINTEED. E. FOLLOW MANUFACTURERS INSTRUCTIONS ON PRODUCT STORAGE AND HANDLING. F. INSTALL INSULATION IN ACCORDANCE WITH MANUFACTURERS INSTALLATION INSTRUCTIONS AND AS SHOWN ON PLANS. VII. SEALANTS A. CAULK AROUND ALL WINDOWS, DOORS, VENT OPENINGS, WHERE DIFFERENT MATERIALS MEET, ROOF OPENINGS, EAVES, SOFFITS, JOINTS, COUNTERTOPS, DOOR FRAMES, ETC. AND AS REQUIRED FOR A WATERTIGHT CONNECTION. PROVIDE SONNEBORN SONOLASTIC NP2 FOR ALL CMU CONTROL JOINTS. PROVIDE "TREMCO DYMERIC 240 FC" AT ALL NON -FINISH INTERIOR & EXTERIOR LOCATIONS. SEE FLOOR PLAN. CAULK TO BE INSTALLED AFTER FINISH IS APPLIED TO SURFACES PER MANUFACTURER. VIII. DOORS, WINDOWS AND FRAMES A. REQUIREMENTS 1. FURNISH AND INSTALL ALL DOORS AND WINDOW ASSEMBLIES AS INDICATED ON THE PLANS ALONG WITH ALL HARDWARE INDICATED AND THAT MAY BE REQUIRED FOR A COMPLETE JOB. 2. ALL DOORS AND WINDOWS SHALL OPERATE SMOOTHLY WITHOUT BIND AND BE INSTALLED PLUMB AND TRUE. 3. ALL HARDWARE SHALL FIT PROPERLY AND BE ADJUSTED AS REQUIRED. 4. PROVIDE INSECT SCREENS ON ALL OPERABLE WINDOW UNITS. IX. HARDWARE A. REQUIREMENTS 1. ALL LOCKSETS SHALL BE LEVER TYPE AS REQUIRED TO MEET REQUIREMENTS OF A.D.A. 2. ALL OTHER HARDWARE SHALL CONFORM TO THE REQUIREMENTS OF A.D.A. 3. ALL EXIT DOORS SHALL BE EQUIPPED WITH LEVER TYPE OR PANIC TYPE EXIT HARDWARE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A LATCH, KEY OR BOLT. 4. CONTRACTOR TO COORDINATE KEYING SCHEDULE WITH OWNER. X. SAFETY GLAZING A. PROVIDE SAFETY GLASS IN ALL GLAZING AS LISTED BELOW UNLESS NOTED OTHERWISE: 1. WHERE REQUIRED BY FEDERAL, STATE AND LOCAL CODES. B. SAFETY GLASS REQUIREMENTS 1. SAFETY GLASS SHALL BE, BUT NOT LIMITED TO A. TEMPERED GLASS B. LAMINATED GLASS C. SAFETY PLASTIC D. SAFETY INSULATING UNITS WHICH MEET THE TEST REQUIREMENTS OF ANSI Z97.1, AND WHICH ARE CONSTRUCTED, TREATED, OR COMBINED WITH OTHER MATERIALS SO AS TO MINIMIZE THE LIKELIHOOD OF CUTTING AND PIERCING INJURIES RESULTING FROM HUMAN IMPACT WITH THE GLAZING MATERIAL. 2. ALL SAFETY GLAZING MATERIAL SHALL BE LABELED PER LOCAL, STATE, AND FEDERAL REQUIREMENTS. XL DRYWALL STUDS (INTERIOR NON -BEARING) A. REQUIREMENTS 1. STUDS SHALL BE SECURED TO TOP AND BOTTOM TRACK WITH (1) #8ML SCREW IN EACH FLANGE (UNLESS A SLIP TRACK IS REQUIRED AT THE TOP OF THE WALL). 2. PROVIDE SLIP TRACK AT TOP OF FULL HEIGHT PARTITIONS. 3. STUDS SHALL BE INSTALLED PER "GYPSUM CONSTRUCTION HANDBOOK" AS PUBLISHED BY UNITED STATES GYPSUM COMPANY LATEST EDITION. 4. DRYWALL STUDS SHALL BE INDICATED ON THE PLANS. XII. DRYWALL A. DRYWALL SHALL BE INSTALLED PER THE LATEST EDITIONS OF "RECOMMENDED SPECIFICATIONS FOR THE APPLICATION AND FINISHING OF GYPSUM BOARD" GA-216 AS PUBLISHED BY THE GYPSUM ASSOCIATION AND THE "GYPSUM CONSTRUCTION HANDBOOK" AS PUBLISHED BY UNITED STATES GYPSUM COMPANY. 1. PROVIDE CONTROL JOINTS PER THESE REQUIREMENTS. 2. PROVIDE M.R. DRYWALL AT ALL FRP, CERAMIC WALL TILE, PORCELAIN WALL TILE, COOLER PANEL, FREEZER PANEL AND DAMP/WET LOCATIONS. B. DRYWALL FINISHES SHALL BE INSTALLED PER THE LATEST EDITION OF "RECOMMENDED LEVELS OF GYPSUM BOARD FINISH" GA-214-96 AS PUBLISHED BY THE AWCI, PAINTING AND DECORATING CONTRACTORS OF AMERICA, GYPSUM ASSOCIATION AND CISCA. PROVIDE A LEVEL 1 FINISH AT ALL UNEXPOSED AREAS OR AS NOTED ON PLANS. C. LEVELS OF FINISH: 1. LEVEL 4 JOINTS AND INTERIOR ANGLES HAVE TAPE EMBEDDED IN JOINT COMPOUND AND TWO SEPARATE COATS OF JOINT COMPOUND APPLIED OVER ALL FLAT JOINTS AND ONE SEPARATE COAT APPLIED OVER INTERIOR ANGLES; FASTENER HEADS AND ACCESSORIES ARE COVERED WITH THREE (3) SEPARATE COATS OF JOINT COMPOUND; NO TOOL MARKS OR RIDGES. XIII. FINISHES A. REQUIREMENTS 1. PROVIDE AND INSTALL ALL FINISHES AS INDICATED ON PLANS. 2. INSTALL ALL MATERIALS PER MANUFACTURER'S RECOMMENDATIONS AND SPECIFICATIONS. 3. "FINISH" INSTALLER INSPECT SUBSURFACE AND PREPARE AS PER MANUFACTURER'S SPECIFICATIONS PRIOR TO INSTALLATION OF PRODUCT. 4. ALL FINISHES TO MEET ALL CODE REQUIREMENTS AND REGULATIONS INCLUDING FLAME SPREAD AND SMOKE DEVELOPMENT. XV. SIGNAGE A. REQUIREMENTS 1. CONTRACTOR TO FURNISH AND INSTALL SIGNAGE PER LOCAL, STATE, AND FEDERAL CODES AND PER ROOM FINISH SCHEDULE. 2. ALL SIGNAGE SHALL MEET THE REQUIREMENTS OF THE A.D.A. AND ANSI. 3. WHERE PERMANENT IDENTIFICATION IS PROVIDED FOR ROOMS AND SPACES, SIGNS SHALL BE INSTALLED ON THE WALL ADJACENT TO THE LATCH SIDE OF THE DOOR. WHERE THERE IS NO WALL SPACE TO THE LATCH SIDE OF THE DOOR, INCLUDING AT DOUBLE LEAF DOORS, SIGNS SHALL BE PLACED ON THE NEAREST ADJACENT WALL. 4. MOUNTING HEIGHT SHALL BE 60" ABOVE FINISH FLOOR TO THE CENTERLINE OF THE SIGN UNLESS INDICATED OTHERWISE. 5. PROVIDE HANDICAP PARKING SIGNS_ AS INDICATED ON PLANS AND AS REQUIRED BY LOCAL, STATE, AND FEDERAL CODES. XVI. FIRE EXTINGUISHERS A. REQUIREMENTS 1. CONTRACTOR TO FURNISH AND INSTALL EXTINGUISHERS PER LOCAL, STATE, AND FEDERAL CODES, AND N.F.P.A. NO.10-1978. 2. MOUNT FIRE EXTINGUISHER NOT HIGHER THAN 48" ABOVE FINISH FLOOR UNLESS LOCAL REGULATIONS REQUIRE DIFFERENT HEIGHT. 3. ALL FIRE EXTINGUISHERS AND CABINETS TO MEET THE REQUIREMENTS OF THE A.D.A. AND ANSI A117.1. XVII. TOILET ROOMS A. A.D.A./ANSI A117.1 APPROVED SIGNAGE SHALL BE PROVIDED FOR EACH TOILET ROOM TO DESIGNATE MEN, WOMEN, OR UNISEX. XVIII. FIRE PROTECTION WORK A. SEE FIRE PROTECTION PLANS FOR SPECIFICATIONS. XIV. PAINTING XIX. PLUMBING WORK A. FURNISH ALL LABOR, MATERIALS, TOOLS, EQUIPMENT AND SCAFFOLDING REQUIRED FOR COMPLETING SURFACE PREPARATION, PAINTING, FINISHING AND RELATED ITEMS. A. SEE PLUMBING PLANS FOR SPECIFICATIONS B. EXCESS MATERIALS, CONTAINERS AND OTHER ITEMS NECESSARY FOR THE COMPLETION OF THE WORK MUST BE DISPOSED OF IN A MANNER THAT MEETS OR EXCEEDS THE STRICTEST XX. HEATING AND VENTILATION WORK LAWS GOVERNING THE PROJECTS MUNICIPALITY AND/OR STATE. THE PAINTING CONTRACTOR IS RESPONSIBLE FOR COMPLETE ADHERENCE TO ALL DISPOSAL REGULATIONS. A. SEE HVAC PLANS FOR SPECIFICATIONS. C. PAINT ALL EXPOSED MISCELLANOUS ITEMS, FINISHED OR UNFINISHED (EX. H.V.A.C. RETURN AIR XXI. ELECTRICAL WORK GRILLES, CONDUIT, ETC.) TO MATCH ADJOINING WALL SURFACES. A. SEE ELECTRICAL PLANS FOR SPECIFICATIONS. D. CONTRACTOR TO VERIFY THAT PAINT IS COMPATIBLE WITH PRIMER OF SHOP PRIMED SURFACES. NOTIFY EXCEL ENGINEERING IF THERE ARE ANY COMPATIBILITY ISSUES. E. THE CONTRACTOR SHALL KEEP EMPTY CONTAINERS ON THE PROJECT SITE UNTIL ALL PRODUCTS ARE VERIFIED AS TO COLOR AND/OR SHEEN. THE CONTRACTOR SHALL LEAVE WITH THE OWNER ALL OPENED PAINT CONTAINERS. F. EXTERIOR ITEMS: 1. FERROUS METAL (PRIMED): STRUCTURAL STEEL, MISCELLANEOUS IRON, HANDRAILS, HOLLOW METAL DOORS AND FRAMES, ROOF STRUCTURE, EXPOSED ROOF PIPING, ETC.: A. ALKYD SHOP PRIMER ON METAL 2. 1 COAT S-W KEM BOND HS UNIVERSAL METAL PRIMER B50 SERIES. 3. 2 COATS METALATEX SEMI -GLOSS COATING B42 SERIES. 4. GALVANIZED: A. 2 COATS S-W METALATEX SEMI -GLOSS COATING B42 SERIES. 5. CONCRETE: A. 1 COAT S-W LOXON XP A24W300 SERIES (8 MILS WET, 3.2 MILS DRY). B. 2 COAT S-W A-100 EXTERIOR LATEX SATIN A83 SERIES (4 MILS WET, 1.4 MILS DRY). G. INTERIOR ITEMS: 1. DRYWALL FINISH: EG-SHEL A. 1 COAT S-W PREPRITE 200 LATEX PRIMER B28 SERIES (4 MILS WET, 1.2 MILS DRY). B. 2 COATS S-W PROMAR 200 INTERIOR LATEX EG-SHEL B20 SERIES (4 MILS WET, 1.5 MILS DRY/C OAT). 2. DRYWALL FINISH: FLAT A. 1 COAT S-W PREPRITE 200 LATEX PRIMER B28 SERIES (4 MILS WET, 1.2 MILS DRY). B. 2 COATS S-W PROMAR 200 INTERIOR LATEX FLAT B30 SERIES (4 MILS WET, 1.4 MILS DRY/C OAT). 3. DRYWALL FINISH: SATIN A. 1 COAT S-W PREPRITE 200 LATEX PRIMER B28 SERIES (4 MILS WET, 1.2 MILS DRY). B. 2 COATS S-W DURATION HOME LATEX SATIN B97 SERIES (4 MILS WET, 1.5 MILS DRY/COAT)- 4. DRYWALL FINISH: SEMI -GLOSS A. 1 COAT S-W PREPRITE 200 LATEX PRIMER B28 SERIES (4 MILS WET, 1.2 MILS DRY). B. 2 COATS S-W PROMAR 200 INTERIOR LATEX SEMI -GLOSS B31 SERIES (4 MILS WET, 1.3 MILS DRY/COAT). 5. DRYWALL FINISH: EPDXY SYSTEM SEMI -GLOSS A. 1 COAT S-W PREPRITE CLASSIC LATEX PRIMER 628 SERIES (4 MILS WET, 1.2 MILS DRY). B. 2 COATS S-W WATER BASED CATALYZED EPDXY B 70 SERIES (2.5 3 MILS DRY/COAT). 6. NEW WOOD, STAINED: A. 1 COAT S-W WOOD CLASSICS INTERIOR OIL STAIN A49 SERIES. B. 1 COAT S-W WOOD CLASSICS POLYURETHANE GLOSS VARNISH A67V1. C. 1 COAT S-W WOOD CLASSICS POLYURETHAN SATIN VARNISH A67 SERIES (4 MILS WET, 1.4 MILS DRY/COAT). 7. NEW WOOD, PAINTED: A. 1 COAT S-W PREPRITED CLASSIC INTERIOR LATEX PRIMER B28 SERIES (4 MILS WET, 1.6 MILS DRY). B. 2 COATS S-W DURATION HOME LATEX SATIN B97 SERIES (4 MILS WET, 1.5 MILS DRY/C OAT). 8. FERROUS METAL (PRIMED, BRUSH/ROLLER) DOORS, FRAMES, HANDRAILS, MISC. METALS, ETC.: AC RYLIC A. 1 COAT S-W DTM ACRYLIC PRIMER/FINISH 366W1 (2.5 4 MILS DRY/COAT). B. 2 COATS S-W DTM ACRYLIC PRIMER/FINISH B66W1 (2.5 4 MILS DRY/COAT). 9. FERROUS METAL (PRIMER, SPRAYED), ALL EXPOSED STRUCTURAL STEEL AND EXPOSED MECHANICAL/ELECTRICAL ITEMS: ACRYLIC A. 1 COAT S-W DTM ACRYLIC PRIMER/FINISH 366W1 (2.5 4 MILS DRY/COAT). B. 1-2 COATS S-W SUPER SAVE-LITE HI-TEC DRYFALL. B48 SERIES (6 MILS WET, 3 MILS DRY). 10. GALVANIZED: A. BRUSH/ROLLER: 2 COATS S-W DTM ACRYLIC COATING SEMI -GLOSS B66 SERIES (2 MILS DRY/COAT). B. SPRAYED: 1 COAT S-W GALVITE HS B50WZ30 (5 MILS WET, 3 MILS DRY) AND 2 COATS S- W SUPER SAVE-LITE HI-TEC DRYFALL B48 SERIES (4 MILS WET, 2 MILS DRY). 11. ALUMINUM: A. 2 COATS S-W METALATEX SEMI -GLOSS COATING B42 SERIES (4 MILS WET, 1.5 MILS DRY/C OAT). H. REMOVE AND/OR PROTECT ALL HARDWARE, HARDWARE ACCESSORIES, MACHINED SURFACES, PLATES, LIGHTING FIXTURES, SPRINKLER HEADS AND SIMILAR ITEMS THAT ARE NOT TO BE PAINTED, BUT REQUIRE PROTECTION FROM THE PAINTING PROCESS. RE -INSTALL SAME AFTER COMPLETION OF PAINTING. MASK OFF ALL NAMEPLATES, EQUIPMENT IDENTIFICATION AND SIMILAR ITEMS. REMOVAL AND REINSTALL OF ITEMS IS TO BE DONE BY CONTRACTOR SKILLED IN SUCH WORK. I. SEAL TOPS, BOTTOMS AND CUTOUTS OF UNPRIMED WOOD DOORS WITH A HEAVY COAT OF SEALER IMMEDIATELY UPON DELIVERY TO THE PROJECT. J. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROPER PREPARATION OF ALL SURFACES PRIOR TO THE PAINTING INSTALLATION. K. THE FINISH PRODUCT SHALL HAVE A CONSISTENT, SMOOTH APPEARANCE OF THE SPECIFIED LUSTER. L. APPLY PAINT PER MANUFACTURERS TEMPERATURE AND HUMIDITY REQUIREMENTS- M. COMPLETED WORK SHALL BE FREE FROM DEFECTS AND FLAWS. N. PROVIDE A YELLOW STRIPED AREA, 3 DEEP BY THE WIDTH OF THE ELECTRICAL PANELS, ON THE CONCRETE FLOOR IN FRONT OF THE ELECTRICAL PANELS AND SWITCHGEAR IN THE RECEIVING AREA. AT THE- SWITCHGEAR, PAINT- THE EXPOSED PORTION OF THE CONCRETE HOUSEKEEPING PAD YELLOW. .. ExCEL ENGINEERING;. Lo CD z � � W Q O W IZ 0 a Z Q LdLd Lj z ry U Ld acne U) [-- •• z ly- Ld U Q ��• LLJ LL Q C) � W Q cn Z Z w V) 0- 'T-- C/) cf) 00 Q O Q N w 0 N W W D V) Z w *0 U � 0 > m Ln W M a- D __j J .. _j Q Q 0 z CO J U W J W OW a_ 0 (2- L'J O I� 12- W n a N rl_ N ■ DATE: NOV. 23, 2009 Z IS JOBNUMBER: 914790 W W z SHEET W J W U X T 2 W o pe111��I��,L�I�I�i�L��i� ^VICT icc nnwr-n nic r-n DEMOLITION PLAN p Z SCALE: ,H • ALL DEMOLITION BY GENERAL CONTRACTOR UNLESS NOTED OTHERWISE. • GENERAL CONTRACTOR TO FIELD VERIFY ALL DIMENSIONS. LOCATIONS OF WALLS, DOORS AND OTHER ITEMS HAVE BEEN FIELD MEASURED FOR GENERAL LAYOUT ONLY. REPORT ANY DISCREPANCIES TO ASPEN DENTAL MANAGEMENT FOR CLARIFICATION PRIOR TO THE START OF WORK. • WHERE REMOVAL OF PIPES, CONDUIT, DUCTWORK, ETC. HAS LEFT AN OPENING, FILL AND PATCH OPENING TO MATCH THE ADJACENT CONSTRUCTION AND FINISH AS REQUIRED. • PATCH ALL WORK AT REMOVAL AND NEW CONNECTION POINTS AS REQUIRED TO MATCH ADJACENT NEW OR EXISTING FINISHES. • BEFORE COMMENCING WITH DEMOLITION WORK, REVIEW WITH THE OWNER WHICH ITEMS ARE TO BE SALVAGED AND TURNED OVER TO THE OWNER, IN ADDITION TO THOSE LISTED ON THE PLAN. ANY ITEM NOT WANTED BY THE OWNER SHALL BE REMOVED FROM THE JOB SITE BY THE GENERAL CONTRACTOR AND DISPOSED OF IN THE PROPER AND LEGAL MANNER. • REMOVE ANY WALL FINISHES / BASE FINISHES ON ALL WALLS TO REMAIN BACK TO PLAIN GYP. BD. AND PREP FOR NEW FINISHED PER ROOM FINISH PLAN. • ELECTRICAL: FOR DEMOLITION PRICING PURPOSES, CONTRACTORS BID SHALL INCLUDE PRICE TO PROVIDE COMPLETE DEMOLITION OF ALL ELECTRICAL ITEMS AND DEVICES IN EXISTING BUILDING NECESSARY TO FACILITATE NEW CONSTRUCTION UNLESS OTHERWISE NOTED. CONTRACOTR SHALL FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO BID. NO ADDITIONAL COST WILL BE ALLOWED FOR ADDITIONAL DEMOLITION OF DEVICES NOT SHOWN OR LOCATED. ANY AND ALL ABANDONED LOW VOLTAGE CABLING TO BE REMOVED PER NEC REQUIREMNTS. EXISTING CONDUIT MAY BE RE -USED IN NEW CONSTRUCTION AT CONTRACTORS DISCRETION. • H VAC: FOR DEMOLITION PRICING PURPOSES, CONTRACTORS BID SHALL INCLUDE PRICE TO PROVIDE COMPLETE DEMOLITION OF GRILLES, DUCTWORK AND DUCTWORK ACCESSORIES, BACK TO ROOFTOPS, IN EXISTING BUILDING NECESSARY TO FACILITATE NEW CONSTRUCTION UNLESS OTHERWISE NOTED. CONTRACOTR SHALL FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO BID. NO ADITIONAL COST WILL BE ALLOWED FOR ADDITIONAL DEMOLITION OF DEVICES NOT SHOWN OR LOCATED. • PLUMBING: FOR DEMOLITION PRICING PURPOSES, CONTRACTORS BID SHALL INCLUDE PRICE TO PROVIDE COMPLETE DEMOLITION OF FIXTURES AND PIPING IN EXISTING BUILDING NECESSARY TO FACILITATE NEW CONSTRUCTION UNLESS OTHERWISE NOTED. ALL EXISTING PIPING TO BE CAPPED IN FLOOR, EXISTING PIPING IN WALLS MAY BE CAPPED IN WALL UNLESS WALL NOTED AS DEMO. CONTRACOTR SHALL FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO BID. NO ADITIONAL COST WILL BE ALLOWED FOR ADDITIONAL DEMOLITION OF DEVICES NOT SHOWN OR LOCATED. -SEE PLUMBING DEMO PLAN PD1.1 FOR ADDITIONAL INFORMATION. DEMOLITION KEYNOTES: Oi REMOVE EXISTING DOOR AND FRAME, INCLUDING ALL HARDWARE AND ACCESSORIES. OREMOVE EXISTING WALL IN ITS ENTIRETY. PRIOR TO REMOVAL, DETERMINE IF WALL IS BEARING. IF BEARING, NOTIFY EXCEL ENGINEERING PRIOR TO REMOVAL. O3 REMOVE EXISTING CEILING TILE AND METAL GRID IN ITS ENTIRETY AND PREPARE AREA FOR NEW CEILING AS SHOWN IN THE ROOM FINISH. SCHEDULE. OREMOVE EXISTING FLOOR FINISH IN ITS ENTIRETY DOWN TO BARE, CLEAN SUBSTRATE. PATCH AND REPAIR SUBSTRATE FLOOR FLAT SMOOTH FINISH AS REQUIRED. SEE ROOM FINISH SCHEDULE FOR NEW FLOOR FINISHES. OREMOVE EXISTING TOILET PARTITIONS, GRAB BARS, AND ASSOCIATED ACCESSORIES. OREMOVE EXISTING PLUMBING FIXTURES/PIPE STUBS. DEMO EXISTING PIPING AS REQ'D FOR NEW CONSTRUCTION. CAP AND PATCH FLOOR SLAB AS REQ'D. O7 REMOVE EXISTING MECHANICAL GRILLS / EXHAUST VENTS AND ASSOCIATED DUCT WORK BACK TO RTU DROPS AS REQ'D FOR NEW MECHANICAL DUCT RUNS AND GRILLS. O8 REMOVE ALL EXISTING LIGHT FIXTURES AND ASSOCIATED WIREING PER CODE AS REQ'D FOR NEW LIGHTING DESIGN. ALL WIRING TO BE PULLED BACK AND TERMINATED AT PANELS. OREMOVE AND RELOCATE EXISTING ELEC. PANELS FOR REUSE IN NEW MECHANICAL ROOM AS REQ'D. -SEE ELEC. DWG'S. 10 REMOVE ANY REMAINING WALL ART OR ORDERING BOARDS AS REQ'D FOR NEW CONSTRUCTION. COORDINATE DISPOSAL W/ OWNER. 11 LANDLORD TO REMOVE EXISTING ELECTRIC WATER COOLER ALONG WITH ASSOCIATED PLUMBING AND ELECTRICAL CONNECTIONS. 12 LANDLORD TO REMOVE EXISTING SERVICE SINK ALONG WITH ANY PLUMBING CONNECTIONS. 13 LANDLORD TO REMOVE EXISTING WATER HEATER ALONG WITH ANY PLUMBING/ELECTRICAL CONNECTIONS. M,,EXCEL ENGINEERINGIM 100 CAMELOT DRIVE FOND DU LAC, WI 54935 PHONE: (920) 926-9800 FAX (920) 926-9801 Always a Better Plan Lrn O � M a Z Y c1f W f3f O W 0- Q Z Y W W Z Q W U Li J F- W (n .. Z W U Q Lio z >_ Z Z ((f) W F— Oa°N°LQ Q_ r N N I Q W I— D (n W W � Z W Z U w j Q CL D J J W Q N • • Z J �— J U W J M J W 0� l• � Z I m (!) CL W O CL W C Q N N SHEET ISSUE: NOVEMBER 23, 2009 SEE TITLE SHEET TO CONFIRM THAT THIS SHEET HAS BEEN RELEASED FOR CONSTRUCTION REVISIONS: DATE: NOV. 23, 2009 JOB NUMBER: 914790 SHEET J W U X W Aspen[D(a= o D1.1 0) 0 04 DOOR SCHEDULE PARTITION TYPES DOOR SIZE DOOR FRAME HARDWARE W � ui N W � Y Y v m V EXISTING STRUCTURE EXISTING STRUCTURE Lu rn � O z W w = Y W W N W tan a 3 5/8" 20 GA. 3 5/8" 20 GA. METAL Y G 3 = F `z a a a METAL FRAMING @ FRAMING @ 48 O.C. IL a REMARKS 48" O.C. FASTEN ,.1 FASTEN TO ROOF 101 3'- 0" 6' - 8" 1 3/4" C A 1 • TO ROOF FRAMING E FRAMING W 102 3'- 0" 6' - 8" 1 3/4" B A 2 • UNDERCUT 1" ' 105 3'- 0" 6' - 8" 1 3/4" B A 3 • 106A 3'- 0" 6' - 8" 1 3/4" D A 17 3 • CEILING AS SCHEDULED CEILING AS SCHEDULED 106E T- 0" 6' - 9' 1 1 3/4" B a A a 3 • SOUND INSULATION (Al SOUND INSULATION (B1 108 3'-- 0" 6' - 8" 1 3/4" B W A W 3 • ONLY)FLAME SPREAD ONLY) FLAME SPREAD OF w W 111 3'- 0" 6' - 8" 1 3/4" D = A x 3 • OF 25 OR LESS AND >25 OR LESS AND SMOKE 115 3'- 0" 6' - 8" 1 3/4" B w A w 3 • SMOKE DEVELOPMENT = DEVELOPMENT OF 450 116 3'- 0" 6' - 8" 1 3/4" D A 3 • OF 450 OR LESS =" OR LESS 3 5/8" 20 ga. MTL FRAMING 119 3'- 0" 6' - 8" 1 1 3/4" 1 B A 2 • UNDERCUT 1" 121 3' - 0" 6' - 8" 1 3/4" B A 1 • 3 5/8" 20 ga. MTL FRAMING ` " @ O.C. MTL. STUDS 122 6' - 0" 6' - 8" 1 3/4" B - _ 1 @ 16" O.C. (6" MTL. STUDS @ PLUMBING WALLS @ PLUMBING WALLS AS REQ'D) AS REQ'D) (2) LAYERS 5/8" GYP DOOR SCHEDULE REMARKS BD. INSIDE X-RAY 1. PROVIDE (2) 3'-0" x 6'-8" SLIDING DOORS ( DOOR TYPE SCHEDULED ABOVE) ROOM -WIDTH SHOWN IN SCHEDULE REFERS TO FINISHED OPENING SIZE. 5/8" TYPE "X" GYP -ALL REQ'D HARDWARE & ACCESSORIES BY DOOR SUPPLIER. BD. BOTH SIDES (1) LAYER 5/8" GYP BD. EXIST. DOORS/HARDWARE BY LANDLORD HAVE BEEN REVIEWED & APPROVED IN BUILDING SHELL/WHITE BOX SUBMITTAL BASE AS SCHEDULED (DOOR HARDWARE SHALL BE CAPABLE OF OPERATION WITH THE USE OF ONE (1) HAND AND SHALL NOT REQUIRE TIGHT STEEL CHANNEL BASE AS SCHEDULED ---- PINCHING, TIGHT GRASPING OR TWISTING OF THE WRIST TO OPERATE. THUMB TURN DEADBOLTS ARE PROHIBITED AT STEEL CHANNEL INTERIOR. IF PROVIDED AT EXTERIOR (PER 1008.8.3) PROVIDE REDILY VISIBLE PERMANENT SIGNAGE ON OR ADJACENT FINISHED FLOOR AS TO DOOR STATING: 'THIS DOOR TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED' -SEE SHEET A5.0 FOR SIGN SCHEDULED FINISHED FLOOR AS DETAILS. LEVER OR PADDLE DEADBOLTS RELEASES ARE ACCEPTABLE. DOOR THRESHOLD SHALL NOT EXCEED 1/2" IN SCHEDULED HEIGHT, THRESHOLDS EXCEEDING 1/4" IN HEIGHT SHALL HAVE A 1:2 BEVEL. DOOR CLOSERS SHALL MEET OPENING FORCE AND SWEEP PERIOD REQUIREMENTS.) ❑ A - PROVIDE TACTILE EXIT SIGNAGE AT ALL EXIT DOORS -SEE SHEET A5.0 STANDARD DOOR TYPES 4" 4" 4" TYP. TYP. TYP. J _I J _j IDE O O O O STOREFRONT: FLUSH SOLID 15 LITE FRENCH FLUSH SOLID CORE NOTE: TEMPERED CORE BIRCH SOLID CORE BIRCH W/ SIDELIGHT: ALL DIMS TYPICAL SAFETY GLASS BIRCH DOOR: TEMPERED UNLESS NOTED TEMPERED SAFETY GLASS SAFETY GLASS HARDWARE TYPES ` SET 1 SET 3 SCHLAGE "RHODES" D 10 S SCHLAGE "RHODES" D 10 S HINGES: STANLEY, F179 4 1/2" x 4 1/2", 1 1/2 HINGES: STANLEY, F179 4 1/2" x 4 1/2", PAIR PER DOOR 1 1/2 PR. PER DOOR CLOSER: ICN 4000 SERIES WALL BUMPER: TRIMCO 1276 WALL BUMPER: TRIMCO 1276 SET 2 HARDWARE NOTES: SCHLAGE "RHODES" D 40 S 1. CONTRACTOR TO SUBMIT DETAILED HARDWARE SCHEDULE WITH HINGES: STANLEY, F179 4 1/2" x 4 1/2", COMPLETE CUT -SHEETS TO OWNER FOR FINAL APPROVAL. 1 1/2 PAIR PER DOOR 2. RHODES LEVER OR EQUAL. CLOSER: ICN 4000 SERIES 3. EXTERIOR HARDWARE AS SELECTED BY OWNER TO BE LEVER WALL BUMPER: TRIMCO 1276 STYLE. INSIDE LEVER SHALL ALWAYS BE ACTIVE. DEADBOLT LOCK IF GENDER SIGN (SEE SHEET A5.0) REQUIRED SHALL BE OPERATED BY KEY OUTSIDE AND THUMBTURN INSIDE (EXT. DOOR LOCATIONS ONLY). REUSE EXISTING IF APPLICABLE. MILWORK NOTES z EXIST. ALUM. — WINDOW w 1/4" PROJ. ALL MILLWORK SHOWN HATCHED IS NOT IN WHEN HATCHED AS WHEN HATCHED AS CONTRACT & IS TO BE PART OF SEPARATE SHOWN, MILLWORK SHOWN, MILLWORK & PACKAGE PROVIDED BY OWNERS MILLWORK PROVIDED AS SINK PROVIDED AS v VENDER. G.C. SHALL BE RESPONSIBLE INDICATED ABOVE INDICATED ABOVE G.C. `) FOR COORDINATING DELIVERY OF BUT SINK IS TO BE TO INSTALL. EXIST. WALL MILLWORK AND PROVIDING AND INSTALLING PROVIDED AND ASSEMBLY ALL REQUIRED UTILITIES FOR A COMPLETE INSTALLED BY G.C. WORKING SYSTEM UNLESS NOTED OTHERWISE, TYP. SILL PROFILE FLOOR PLAN KEYNOTES O WALL MOUNTED PLASMA TV. G.C. 16 REFRIGERATOR BY OTHERS TO PROVIDE APPROPRIATE BLK'G AT 60" A.F.F. 17 EQUIPMENT BY OTHERS O2 42" HIGH WALL BY MILLWORK VENDOR 18 (4) FIRE EXTINGUISHER BY TENANT -SEE DETAIL 5/A5.1 O3 SHELVING BY MILLWORK VENDOR 19 4 HR. RATED MASONRY EXTERIOR SHELL WALL, CONTRACTOR O4 SOFFIT ABOVE TO COORDINATE ALL EQUIPMENT BLOCKING & UTILITIES PRIOR TO INSTALLING GYP. BD. O 54" HIGH WALL BY MILLWORK VENDOR -IF GYP. BD. IS EXISTING, REMOVE GYP. BD. AS REQ'D COMPLETE WORKAND PATCH WALL, FIRE CAULK AS REQ'D. O T SHELVES PATCH EXISTING GYP. BD. TO MATCH FOLLOWING DEMOLITION 20 PLUMB. CONTRACTOR. TO COORDINATE. CLEARANCES O FILING CABINETS REQ'D FOR LANDLORD SUPPLIED EQUIPMENT PRIOR TO INSTALLING WATER HEATER / MOP SINK 21 6' SHELVES ® 8'SHELVES 22 EXISTING 1 HR. FIRE RATED INTERIOR NON -BEARING O9 ELEC. WATER COOLER DEMISING WALL -CONTRACTOR TO COORDINATE ALL -SEE ELEC. &PLUMB. EQUIPMENT FIRE TREATED BLOCKING & FIRE CAULK ALL UTILITIES PENETRATIONS PRIOR TO INSTALLING GYP. BD. -IF GYP. BD. IS EXISTING, REMOVE GYP. BD. AS REQ'D, 10 ARTICULATOR RACK COMPLETE WORK IN ACCORDANCE W/ WALL RATING, PATCH, FIRE CAULK WALL AS REQ'D. -PATCH EXISTING 11 PLASTER CART GYP. BD. TO MATCH FOLLOWING DEMOLITION 23 G.C. TO PROVIDE 50 GAL. STAINLESS STEEL 12 PHONE CABINET CANISTER, GRADE MOUNTED PROPANE TANK. PROVIDE PVC OR CONC. PAD FOR TANK TO REMAIN LEVEL & ACCESSIBLE FOR REFILL / MAINTANANCE. 13 ELECTRICAL PANELS PIPE TO INTERIOR LAB PER MEP DRAWINGS. CAULK ALL PENETRATIONS AT EXISTING TO MATCH TYP. 14 PHONE BOARD TANK SUPPLIER TO INSTALL PER BUILDING/FIRE CODES TYP. SERVICE/CONTRACT FOR PROPANE TO 15 3'-0"x3'-0" PASS-THRU W/ BE SWITCHED OVER TO ASPEN DENTAL AT TIME OF SANDBLASTED GLASS SLIDING SPACE OCCUPANCY. WINDOW @ 4'-0" A.F.F. WRAP 24 50" HIGH WALL w/ P.LAM CAP BY MILLWORK SUPPLIER. SILL HEADER & JAMBS W/ GWB PROVIDE SOFFIT ABOVE 25 WATER DISTILLER Al SOUND ATTENUATION PARTITION A2 SEE NOTE #24 B❑ X-RAY WALL B1 �^ X-RAY WALL W/ SOUND ATTENUATION 4'-10 3/4" 7'-1 1/2" 5" V-9" 5" 6'-9" 5" 4'-7 1/2" �A�. 2 1 A5.1 A5.1 — I TRA-0RAL X Y FE _ 18 -�9., I � — — 61 EN'S RESTROOM) I PANORAMIC X-RAY \ ..... N STORAGE 108 P. 102 103 I Q Al / . 00 I TYP. N I I B 3/ N CO ll'-101/2� 2'-2" 1/4' 101 2' 4 1 /4" 3'-0" 1'-10 1 /2 3'-2" 3'-0"[2!-0 1 /2" T-0" 6" A5.0 4 10 f A5.0 /4 12'-13/4" 8'-8" z — � � N 2 4 I o — .... I o 3 f'f1 r`fi"' ol 10'-7" I y l w I 8' 2 I, 2'-8" CORRIDOR 5 10'-7" 7 8'-0 1/4" 105 NOTES: - WALL THICKNESSES SHOWN AS A NOMINAL 4",5" OR 7 1/4", 8" @ X-RAY WALLS - ALL METAL STUD FRAMING SHALL BE 20 ga. UNLESS NOTED OTHERWISE EXISTING WALL TENANT SUPPLIED AND INSTALLED P. LAM. CAP W/ LANDLORD SUPPLIED AND INSTALLED GYP. BD. RETURNS LIGHT GAGE CLIP FASTEN TO EXISTING WALL -BY LIGHT GAGE ~ I I SUPPLIER 2 i I 6" 20 ga. MTL. FRAMING _ I I @ 16" O.C. J I I J 9 5/8" GYP BD. z I I BASE AS SCHEDULED of 0 I I STEEL CHANNEL I FINISHED FLOOR AS SCHEDULED ❑C \ :`',; KNEE WALL TR#1 109 TR#2 110 1 V-7" 1 U-0 1/2" 83'-4 3/4" f�f o v ? 4'-3" 1'-6" X-0" T-4 3/4" 00 CONSULTATION H 106 10'-5" TRH C 8'-11 1/2" H omua FLOOR PLAN SCALE: 1/4" = 1'-0" 12'-0" STERILIZATION 17 1 44 19'-9 1/4" FRAME TYPES 5/8 3 1/2" SOUND INSUL. 5/8" GYP. BD. BOTH SIDES SEALANT - BOTH " SIDES OF FRAME 3 5/8" STL. TRACK o(9 H.M. DRYWALL DOORFRAME DOOR -SEE DOOR SCHEDULE HEAD 3 1/2" SOUND INSUL. 5/8" GYP. BD. BOTH SIDES SEALANT - BOTH SIDES OF FRAME PROVIDE DBL. 16 GA. = 3 5/8" STL. JAMB STUDS p H.M. DRYWALL 09 DOORFRAME DOOR -SEE DOOR SCHEDULE FRAME TYPE A 13'-0 3/4" 5"--.,. _ 6-6" V `� 12 ao N rn NG zt TR #3 N M 19 116 I `' N 7 w — — — — — — — — EXIS ING ---- —X11 --� I ON RETE "' STO P 4'-0" '-5 1 /4 T-0" V-6" 8'-10 1/2" 3'-0" 4'-4" 5'- 4 z 2 4 �� TR #6 113 C 41'-4 3/4" 43'-9" U7 Q Z cj:� Ld :2Q Cj.,f O W CL 0 Q � > > Z Q Ld Lj Ld Z U Ld < V) V) � .N. z � Ld U Q LL Q Z Ld Q cn Z Ld CIO QL v--- V) V) 00 Q O Q N Ld Q N Li �V) W D Z L,J *0 "t U _ m M LdM EL D _j J J � .. J Q 0 Q 0 J J U LLJ J J - W o Z r >- O Ld = = E. V) CL LiJ O I-, a. LLJ n Q N I-- N HEET ISSUE: NOVEMBER 23, 2009 SEE TITLE SHEET TO CONFIM THAT THIS SHEET HAS BEEN ISSUED FOR CONSTRUCTION REVISIONS: " 7 JOIST TOP CHORD L 4x4xlxO'- CA OF JOISTS SEE PLAN 1. LOCATE L3x3xl BELOW ALL EQUIP. CURBS AND AROUND ALL ROOF OPENINGS. 2. CONTRACTOR SHALL VERIFY LOCATION & SIZE OF OPENINGS PRIOR TO STEEL FABRICATION, (2) 3 x 3 x 5/16 L's (2) 3 x 3 x 5/16 L's COPE VERT. LEG EA. END O SEE HVAC PLANS FOR LOCATION AND OPENING SIZE REQUIRED O DETAIL TYPICAL AT OPENINGS GREATER THAN 1'-0" INCLUDING ROOF DRAINS AND SUMPS TYP. FRAMING Q DECK OPENINGS NO SCALE NOT REFERENCED ON PLAN CURB BY HVAC CONTRACTOR ANY 5TL. FRAMING REG2'D. G&A5 - COORDINATE ABOVE G&xI5 FOR SUPPORT EXACT LOCATION 1-V OF ROOF TOP UNIT SHALL BE HVAC. CONTRACTOR SUPPLIED BY HVAC CONTRACTOR II JOIST HANGER FOR HVAC, PLUMBING, FIRE PROTECTION, CONVEYOR5, REFRIGERATION, ETC. TYP. JOIST REINF. @ CONCEN. LOAD NO 56ALE "NOT REFERENCED ON PLAN" OPENING FRAME SCHEDULE UNIT WEIGHT ANGLE SIZE 0 - 675 Ibs. L4x3x1 /4 L.L.H. 676 - 1500 Ibs. L4x3 1 /2x5/16 L.L.H. 1501 - 3000 Ibs. L6x4x3/8 L.L.H. 3001 - 6000 Ibs L6x6x3/8 ROOF TOP CURB 1 \2" DIA. x3" THRU-BOLTS @ 24" O.C. A/C/ SUPPORT FRAME 3/8" DIA. x2" LAG BOLTS 4" FROM EACH TYP. CORNER & 24" O.C. OF 4 MAX. (MIN. 3 PER SIDE) TYP. ALL 4 SIDES. TYP- 3 OF 4 STL. JOIST JOIST WEB STIFF. MECH. CURB FRAMING NO SCALE NOT REFERENCED ON PLAN ROOFING TO F TYP. 0 OF 4 o I EXUi ISTS c RTU i L - - - - - - - - - - - - - - - - - - - - - /_ /_ ---------- --- -- - - - - - - - - - - - - - - EXISJt_ RTU�i ---'------- -------------------------------- w---------------------------------- ol cn --�'----- ------------------------ CLI Or------ V' IVSI EXISTI ® IE=I RTU 0 a 0 --- r - - - - - IL-1 EXISI� L . RTU I L- - - - - - - - - - - - - - - - - - - - - - - - - -- - - - - - - - - - - - - - - w a_ __\ ---------------------------------- J i (/7 w 0 -) r - - - - / -EXIS F� RTU IL ---- ------------------------------------------- -SEE HVAC FOR SPECIFIC ROOF TOP NOTES ,,LJ -SEE DETAILS THIS SHEET FOR STRUCTURAL 0 U, I ATTACHMENT OF NEW R.T.0 ---------------------------------- 1 I I 1 I I I I -------------------11 11 I 1 I I I I I 1 I I --------------------=------------- 11 --- 1 I I 1 I I 1 I I a I I I I 7 I 1 I I ------------------�I 1 I I 1 I I � I II I ---------------------- ------------ I _J — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — I I I I I I I I I I ------------------------------------------11 I I I I 1 I I I I 1 I I ------------ - ----------II I ------------------ I I I I I I I I L-1 I I --------------- 1 I I 1 I I I I 1 I I --------------11 1 I I I 1 I I 1 I I I I I I I - J - - - - - - - - - - - - - - - - - - - - - - - - ---id- ------------------------------- 1--- --------r-----------------------\ -- SLOPE I ------------------------------------- -- ---------- ----------- -------------------- 1 ------------------------------------------ 1 -- Icy EXIST► 13 LLJ RTU o J F 4 1 L----- 1 1 CD TIN �.. - - - - - - - - - - - - - - - - - - - - - - - --- - - - - - - - - - - - - ---D---------- --------------------------------- � I 25'-1 1 /4" 1 I I 1 I I I 1 ! I I --------- ---®° ------------ ---1------------------------------------- ------I I 1 1 I I 0 ' 1 I _.i..._..--- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - ---1-------------------------------------------11 1 I I EXISTI cv 1 I ILA RTU y LI L_---- I 1 1 I I I - - - - - - - - - - - - - ----------i2 -- ® I TYP: 11 TFPS 10 OF 5 1 1 I I ; I I I --------------- ------ - - - - f - - - - - ---1--------------------------------------- II I j OF 5 I 1 cn ` 1 I I I -------------------- - - - - - - - - - - - - - - - - - - ---�-- �---------- II I I n 10 TYP.. 1 1 u 1 � I I I I I J I I I L— — — — — — — — — — -- ,ddfthin, ROOF PLAN NORTH SCALE: 1 /8" = 1'-0" EXISTING ROOF NOTES ❑1 BUILT UP ROOF SYSTEM. PRE -FINISHED ALUMINUM COPING, VERIFY COLOR W/ OWNER 1-31 PRE -FINISHED ALUMINUM DOWNSPOUT ❑4 PRE -FINISHED ALUMINUM SCUPPER PRE -FINISHED ALUMINUM OVERFLOW SCUPPER HVAC UNIT - COORDINATE LOCATION W/ STRUCT. DWGS. ❑7 4" CANT STRIP & BASE FLASHING PRE -FABRICATED VINYL AWNING ❑! ROOF CURB (CAP W/ METAL COVER), FOR FUTURE RTU 10 CRICKET- SLOPE 1/4":1'-O" CONDENSATE LINE -DRAIN TO SCUPPER & DOWNSPOUT (TYP.). ALL CONDENSATE PIPING SHALL BE PVC W/ 1 /2" ARMAFLEX INSULATION 1s ROOF ACCESS LADDER 13 V.T.R.-COORDINATE LOCATION W/ P101 100 CAMELOT DRIVE FOND DU LAC, WI 54935 PHONE: (920) 926-9800 FAX: (920) 926-9801 Always a Bever Plan L0 M Q r ~ Z Y Y � W C)r, Q O W 0- Q Z Y W W Z Q W U LLI J � W 0 •. Z W U Q W 0 Z Z z V) W O CL < � N (/) w N I Q W /Z) v W W � Z Z W W U Q W � J J W •. Q Z J C� 0 _j W = _ of (Y Z >- I CL o CL CL (/) W i-, W CL SHEET ISSUE: NOVEMBER 23, 2009 SEE TITLE SHEET TO CONFIRM THAT THIS SHEET HAS BEEN RELEASED FOR CONSTRUCTION REVISIONS: DATE: Z NOV. 239 2009 z JOB NUMBER: 914790 W Z_ C9 W SHEET w U W fj ASpen[Da ta o Al .2 0 O � D� N �,T/O NEW. FRAMING EVATI ONS STUD FRAMING EXIST. STUDS @ /IST. FRAMING 'EL. 110 - STUD DETAIL A2.0 SCALE: 1 /2" = 1'-0" PAINT EXISTING COPING TO — MATCH E.I.F.S COLOR #1, TYP. T.O. PPET EL. = ARA125 -0 T.O. C.M.U. EL = 120 -0 PAINT EXISTING E.I.F.S. BAND COLOR #1, TYP. EXISTING AWNING TO REMAIN O,T.O. STOREFRONT TEL. = 110 -0—" EXISTING E.I.F.S. TO REMAIN, TYP. ....... FIRST FLOOR - TEL. = 100'-0" PAINT EXISTING E.I.F.S. BAND COLOR #1, TYP. EXISTING STOREFRONT - TO REMAIN UNCHANGED 1" BE] FLA STRUCTUI ANGLE (N E.I.F.S. COLOR #2 ON — BACK SIDE OF PARAPET E.I.F.S. CORNICE COLOR #3, TYP. E.I.F.S. COLOR #2, TYP.- E.I.F.S. MEDALLION COLOR #3, TYP. LIGHT FIXTURE, TYP. - -SEE ELEC. DWG'S (4) #12-14 SCREWS @ EACH CLIP L L 4"x2"x12 GA. x 0'-5 1/2" LONG (50 KSI STEEL) )NNECTION TO OCCUR )" MIN. FROM PUNCHOUT. CLIP CONNECTION SCALE: 3" = 1'-0" 2 A4.0 27'-0 1 /2" 5 EQ. SCORE JOINTS 4.0 A4.0 @ E CON TR A TO FOR STE[ NEW MTL. STUDS FLASH EXISTING ROOF MEMBRANE UP BEHIND FLASHING PROVIDE E.I.F.S. DRAINAGE TRACK @ BOTTOM OF E.I.F.S. PRFINISHED METAL REGLET FLASHING -RUN UP WALL 6" CUT EXISTING ROOF MEMBRANE AND PROVIDE CONT. TERMINATION BAR @ TOP OF EXIST. STUDS EXISTING MTL. STUDS REGLET FLASHING SCALE: 3" = 1'-0" PROVIDE (2) LAYERS ' TREATED PLYWOOD,F TO STUD TRACK PREFINISHED METAL CONT. SNAP STRIP f TRACKS TO BE 125-43 (33 k9i) TRACK TO STUD SCALE: 3" = 1'-0" E.I.F.S. COLOR #2. _8 PREFINISHED MTL. COPING, TYP. TENANT SUPPLIED & INSTALLED SIGNAGE TO BE SUBMITTED IN SEPERATE SUBMITTAL. TENANT TO PROVIDE POWER TO SIGN. -SEE ELEC. DWG'S. -LANDLORD TO PROVIDE NAILABLE SUBSTRATE BEHIND E.I.F.S. FOR ATTACHMENT. 1 /2" 'V' GROOVE SCORE JOINT, TYP. cli ALUM. FRAMED FABRIC AWNING COLOR #1 E.I.F.S. COLOR #2 EXISTING AWINING / BEHIND AWNING �TO REMAIN Li L11 —1 IUH[ EjEEIEEI FRONT ELEVATION SCALE: 1 /8" = 1'-0" EXISTING AWNING TO BE REMOVED E.I.F.S. CORNICE SCALE: 1 1 /2" = 1'-O" PROVIDE BRiDGIN @ 72" O.C. TYP. 1 1 /2" X 16 GA. COLD ROLLED CHANNEL (2) #10-16 SCREWS @ EACH STUD 'THE STEEL NETWORK' BRIDGECLIP BC 600 (BC800 @ 8" STUDS) INSTALL PER MFG. SPECIFICATIONS (2) #10-16 SCREWS @ EACH CLIP 8" MAX. STUD DEPTH BRIDGECLIP ATTACHMENT BRIDGING DETAIL SCALE: 3" = 1'-0" MATERIAL LEDGEND E.I. F. S. COLOR #1 DRYVIT OUTSULATION COLOR TO MATCH BLUE AWNINGS E.I.F.S. COLOR #2 DRYVIT OUTSULATION COLOR: #112 SANDLEWOOD BEIGE TEXTURE: SANDBLAST E.I.F.S. COLOR #3 DRYVIT OUTSULATION COLOR TO MATCH: SHERWIN WILLIAMS SW 6089 'GROUNDED' TEXTURE: SANDBLAST PREFINISHED .METAL COPING PAC -CLAD COLOR: TO MATCH E.I.F.S. COLOR #3 ALUMINUM FRAMED FABRIC CANOPY CANOPY SUPPLIER ASPEN DENTAL BLUE (COORDINATE W/ ASPEN DENTAL) EXISTING AWINING TO REMAIN 100 CAMELOT DRIVE FOND DU LAC, WI 54935 PHONE: (920) 926-9800 FAX: (920) 926-9801 Always a Better Plan Ln 0 Qr Z Y w :m a 0 >_ Ld 0- 3-1 Q Z Y LLJ LLJ Z Q W ry U L J (/) //'�• • LL Ia z 0f Ld U Q W Ld 0 Z Z z V) Ld F- O 0 Q N N w N Q Ld H_ D N Ld Ld F-ZD Z 7- LLJ U L j > w Q D J J J J Q N � ^ • • Z J , J U W J M J WC= = � 0 LJ 0_ 0_ o n o Li l� Lj1 < SHEET ISSUE: NOVEMBER 23, 2009 SEE TITLE SHEET TO CONFIRM THAT THIS SHEET HAS BEEN RELEASED FOR CONSTRUCTION REVISIONS: DATE: Z NOV. 23, 2009 JOB NUMBER: Ld 0 W _R%HFFT J w U x w o A2. 0 rn 0 0 N REMOVE EXISTING MTL. COPING, BLOCKING, & TOP TRACK DOWN TO BARE MTL. STUD Ti-, E;/IST FRAt IN REMOVE EIFS CORNICE ELEMENT & ASSOCIATED BLOCKING BACK TO SUBSTRATE —PROVIDE NEAT TRANSITION FROM EXISTING E.I.F.S. FOR NEW E.I.F.S. CONNECTION TEMPORARILY REMOVE EXISTING BATT INSULATION AS REQ'F FOR NEW STUD PLACEMENT. REPLACE INSULATION AFTER COMPLETED WORK REMOVE EIFS & SHEATHING AS REQ'D TO ALLOW FOR NEW STUD PLACEMENT E110 EXIST. FRAMING V_L 0' _1 REMOVE EXISTING AWNING & ASSOCIATED BLOCKING AS REQ'D FOR NEW AWNING -XI T. FIN F 00R =L. - "10• r 3-'� DEMO WALL SECTION SCALE: 3/4" = 1'-0" 1 A2.0 ) NEW. FRAMING =1 21-6 O�T/O NEW. FRAMING 'rVARIES -SEE ELEVATIONS WALL CONSTRUCTION 1 /2" E.I.F.S. (DRYVIT OUTSULATION) IR + MOISTURE BARRIER /8" 'DENS-GLASS-GOLD'/FIRE _ATED PLYWOOD EXTERIOR SHEATHING, ELEVATIONS FOR LOCATIONS DID NEW 60OS162-97 (50 ksi) MTL. JDS @ 24" O.C. SEE DETAIL 6/A2.0 Z MORE INFO. /8" (VERIFY & MATCH THICKNESS) NS-DECK' EXTERIOR SHEATHING /4" E.I.F.S. COLOR #2 @ EXISTING DF MEMBRANE TERMINATION BAR. 100 CAMELOT DRIVE FOND DU LAC, WI 54935 PHONE: (920) 926-9800 FAX: (920) 926-9801 Always a Betber Plan 1`11- Ln O EXIST.-RAKIING 5( ` Tr 0 EXI T =FAMING Q Z Y W O �OJECTION ADD ADDITIONAL INSULATION UP TO 6" PAST ROOF I Q Y w ......j....... ._.. ....- I Q LW Z UW V) Z W a W 0 W 0 Z .. N O N �OJECTION :�i 00 Q N W SEE ELEC. D WG'S N '-TION ALUM. FRAMED FABRIC CANOPY ............. - -ATTCHMENT BY CANOPY SUPPLIER -G.C. TO VERIFY BLOCKING ANLli D -I PROVIDE IF REQUIRED r" 0 w L LI VIL LLI w ROJECTION w Q >�CLJ J —i ;:I T FR.APr1 iJ >� B Ekl_T FRf1M'fJ J Q EL . 11`i'. I° Q 0 • • (n N Z J J V W -j M W r PROVIDE 3/8" DRAINAGE GAP @ O Ld W CL 0 0- BASE OF E.I.F.S. DO NOT CAULK cy (n W IW 0- SHEET ISSUE: NOVEMBER 23, 2009 SEE TITLE SHEET TO CONFIRM THAT THIS SHEET HAS BEEN RELEASED FOR CONSTRUCTION REVISIONS: DATE: Z NOV. 239 2009 z JOB NUMBER: W 914790 Z L.T1 . F�I UiR`. FOiR ,hrIS w .........C9 SHEET W U X W WALL SECTION A4.0 1 Q A4.0 SCALE: 3/4" = 1'-0" o 04 10'-4" 40" 54" MIN. 12" MAX. 42" 11 co � � o FLUSH CONTROLS TO BE MOUNTED TO THE WIDE SIDE OF THE TOILET AREA mQ O Lu d SIDE VIEW FRONT VIEW O O O 1 1/2"0 GRAB BAR 1 1/2"e GRAB BAR TOILET TISSUE DISPENSER MODEL NUMBER: B-6806 MODEL NUMBER: B-6806 MODEL NUMBER: B-2740 SATIN STAINLESS STEEL SATIN STAINLESS STEEL ALUMINUM W/ SATIN FINISH BY LANDLORD BYLANDLORD BY LANDLORD 15" MIN. 7" MIN. LL DEPT � 24" v rvi N M 8" MIN. Ike 6" MAX. KNEE CLR. TOE CLR. O O 0 7 MIRROR LIQUID SOAP DISPENSER MODEL NUMBER:B-290 SUPPLIED BY ASPEN DENTAL WALL HUNG LAVATORY SATIN STAINLESS STEEL INSTALLED BE G.C. BYLANDLORD BY LANDLORD GENERAL NOTES NEW WORK: 1. ALL CONTRACTORS HIRED BY LANDLORD AND TENANT OR TENANTS CONTRACTORS TO BE LICENSED CONTRACTORS AND PROVIDE W/ PROOF OF INSURANCE (CERTIFICATES) 2. GEN. CONTR. VERIFY W/ LANDLORD & TENANT THAT ALL ELEC. STUBS/ CONDUIT AND ALL PLUMBING BELOW GRADE IS INSTALLED PRIOR TO CONCRETE SLAB BEING POURED. 3. GEN. CONTR. TO VERIFY ALL REQUIRED BLOCKING W/ OWNER FOR OWNERS EQUIP. (IE: EQUIP. TOILET ACCESSORIES, ETC). 4. ALL CONTT. TO CONFORM W/ LOCAL STATE BUILDING CODES AND ORDINANCES. 5. ALL CONST. TO CONFORM W/ ADA STANDARD FOR ACCESSIBILITY. 6. ALL DOOR OFFSETS (HINGE SIDE) TO BE A MIN. OF 4" TYP. 7. ANY ROOM WITH SERVICE SINKS TO BE PROVIDED WITH EXHAUST VENTILATION PER STATE CODE. VERIFY WITH HVAC DESIGN DRAWINGS. 8. ALL MECH. EQUIP. TO BE DIRECT VENT SEALED COMBUSTION - OR ELECTRIC. WATER HEATER EXACT LOCATION TO BE DETERMINED BY PLUMBING DESIGNER. SEE DRAWINGS FOR INFO. 9., F.E. =WALL MOUNTED FIRE EXTINGUISHER, MOUNT AT 4'-0" A.F.F. MAX. TO TOP OF EXTINGUISHER. FIRE EXTINGUISHER TO BE 10# ABC EXTINGUISHER TYPICAL FOR WALL MOUNTED. 10. F.E.C. = RECESSED OR SIM. RECESSED FIRE EXTINGUISHER CABINET, SEE LIFE SAFETY/ PLAN SHEETS FOR ADD. NOTES GENERAL RESPONSIBILITY NOTES: 1. ALL CONTRACTOR RESPONSIBLE TO REVIEW ALL NOTES THIS SHEET. THESE ARE STANDARD MATERIALS AND METHODS FOR CONSTRUCTION. THERE WILL BE %%UNO EXTRAS%%U EXCEPTED BY ANY CONTRACTOR FOR ANY INFO NOT REVIEWED OR MISSED FROM THIS SHEET OF GENERAL NOTES.. 2. NO SUBSTITUTIONS OF MATERIALS OR GENERAL PRACTICES AS CALLED OUT WITHIN THIS DRAWING SET WITHOUT THE WRITTEN APPROVAL FROM THE OWNER -LANDLORD, TENANT, ARCHITECT, OR STRUCTURAL ENGINEER. 3. IMPORTANT CONTRACTOR NOTES: ALL CONTRACTORS TO SUBMIT DESIGN BUILD (FIRE PROTECTION) FOR OWNER/ ARCHITECT REVIEW PRIOR TO STARTING OF WORK. (FIRE PROTECTION DRAWINGS SUBMITTED ONLY WHERE APPLICABLE) 4. ALL CONTRACTORS INCLUDING ELECTRICAL, DATA, TELEPHONE, SOUND AND OR SECURITY TO COORDINATE W/ HVAC CONTRACTOR AND DESIGNER TO VERIFY IF PLENUM AIR RETURNS ARE USED IN THE BUILDING. IF PLENUMS ARE USED ALL CONTRACTORS MUST USE PLENUM RATED WIRE NO ADDITIONAL COSTS WILL BE PASSED ONTO THE BUILDING OWNER FOR LACK OF CONTRACTOR COORDINATION. 5, HVAC DESIGNER AND CONTRACTOR ARE RESPONSIBLE TO COORDINATE W/ GENERAL CONTR./ DRYWALL CONTRACTOR IF PLENUM AIR RETURNS ARE USED IN THE BUILDING. DRYWALL CONTRACTOR MUST RETURN ALL GYP. IN THE AREA OF THE PLENUM TO THE BOTTOM SIDE OF THE STRUCTURE. NO COMBUSTIBLE MATERIAL ALLOWED IN THE PLENUM AREA PER CODE. 6. WHERE APPLICABLE BUILDINGS WITH FIRE SUPPRESSION SYSTEMS FIRE PROTECTION CONTRACTOR WHEN BLEEDING SYSTEM MUST USE A HOSE TO CATCH BASIN OR LAWN AREA. ABSOLUTELY NO DISCHARGE TO GRADE PAVING. IF DONE TO GRADE PAVING FIRE PROTECTION CONTR. RESPONSIBLE FOR CLEANING OF ALL RUST AND OR STAINS TO RETURN THE PAVING TO ORIGINAL CONDITION. 7. GENERAL CONTRACTOR RESPONSIBLE FOR FINAL GENERAL CLEANING PRIOR TO TURN OVER TO LANDLORD AND OR TENANT. GENERAL CONTRACTOR TO CONTACT LANDLORD AND OR TENANT FOR FINAL INSPECTION. 8. GENERAL CONTRACTOR IS TO HAVE WINDOWS CLEANED INSIDE AND OUT BY PROFESSIONAL WINDOW CLEANER. PROPER CLEANING TO BE USED W/ NO RAZOR BLADES USE TO PREVENT GLASS SCRATCHING OR ETCHING. 9. ALL CONTRACTOR TO PROTECT ALL FINISH MATERIALS (IE: ROOFING, PAVING, CARPET, MASONRY, ETC.) WHEN APPLYING PAINT E.I.F.S. OR ANY MATERIAL. GENERAL CONTRACTOR RESPONSIBLE FOR ALL SUBS AND SUB CONTRACTORS ARE RESPONSIBLE FOR ALL CLEANUP COSTS TO REPAIR MATERIAL TO ORIGINAL CONDITION. 10. ' GENERAL CONTRACTOR RESPONSIBLE FOR CONTACTING LANDLORD, TENANT AND ARCHITECT FOR FINAL WALK THRU, PUNCH LIST AND COMPLIANCE STATEMENT PRIOR TO TENANT OCCUPANCY AND FINAL TURN OVER. O WATER CLOSET H.C. ACCESSIBLE BYLANDLORD o v � O SURFACE MOUNTED HAND DRYER AMERICAN SPECIALTIES, INC. MODEL NUMBER: 0185 SUPPLIED BY G.C. INSTALLED BE G.C. R O o SIT THIS DOOR TO SIGN SHALL HAVE RE gU111 tv„U�Jj G'Ala' MAIN UNLOCKED UPPERCASE RAISED MEN MEN WOMEN UNISEX WHEN BUILDING LETTERINGw/ Kc. WOMEN IS OCCUPIED BACKGOUND OF WALL SIGNAGE (TYP.) CONTRASTING COLOR SIGNAGE AT EXT. - LETTERING HGT: 1" (25 mm.) DOORS w/ DEAD BOLTS �i CORRESPONDING GRADE II BRAILLE HEIGHT OF EN, I 3" P. LETTERING 5/8" MIN. TO 2" MAX �---'� WALL MOUNTED SIGNAGE TO BE LETTERING LOCATED ON THE LATCH SIDE OF RAISED 1/32" DOOR CLEAR OF DOOR -SWING _ MOUNT AT 60" TO CENTERLINE y Q UPPER CASE OF SIGN FROM FLOOR LETTERS FINISH FLOOR LINE NOTE: PROVIDE TACTILE EXIT SIGNAGE AT FRONT & REAR EXIT DOORS @ 60" A.F.F. TO THE CENTER OF THE SIGN TOILET ROOM ACCESSORY SPECIFICATIONS: GENERAL NOTES: - SEE TYP. TOILET ROOM ACCESSORY ELEVATIONS FOR MODEL NUMBERS, FINISH AND COLORS - G.C. TO PROVIDE BLOCKING AS REQUIRED AT ALL ACCESSORY LOCATIONS - G.C. TO VERIFY ROUGH OPENING REQUIREMENTS FOR ALL RECESSED MOUNTED EQUIPMENT MANUFACTURER: BOBRICK WASHROOM EQUIPMENT, INC. PRODUCTS: GRAB BARS, TISSUE DISPENSERS, TOWEL DISPENSERS, MIRRORS, SOAP DISPENSERS, ETC. TOILET ROOM NOTES: - 6 1/2" MAXIMUM SINK DEPTH - INSULATE PIPES BELOW COUNTERTOPS (WATER AND WASTE LINES) W/ PVC MOLDED PROTECTION (BY PLUMBING CONTRACTOR) - MANUAL FLUSH VALVE FOR URINAL MUST NOT EXCEED 44" IN HEIGHT 11. ALL SUB CONTRACTORS TO MARK ALL PRIVATE UTILITIES (IE: CONCRETE SLAB NOTES: DATA, SITE LIGHTING, IRRIGATION, ETC) EACH TIME DIGGERS HOTLINE IS CALLED. 1. SAWCUT & REMOVE EXISTING CONC. SLAB AS REQUIRED FOR NEW WORK. CONTRACTOR TO REINF. AND PATCH TO MATCH EXISTING, TYPICAL. 12. GENERAL CONTRACTOR TO NOTIFY ARCHITECT, ENGINEER, TENANT AND LANDLORD OF ANY CHANGE OR DEVIATION FROM PLAN WITH 2. SLAB TO BE PLACED IN A TEMPERED SPACE AND SHALL NOT HAVE ADDITIONAL IN 24 HOURS OF VERIFICATION TO ALLOW AMPLE RESPONSE TIME ADDITIVES IN THE MIXTURE TO AID CURING IN COLD TEMPERATURES OR TO INCREASE IF REVISIONS ARE REQUIRED. CURING TIME BEYOND ACCEPTABLE TIME FRAMES. 13. ALL CONTRACTORS TO REVIEW PROPER PROJECT CLOSE-OUT 3. COORDINATE SLAB CURE TIMES WITH MOISTURE CONTENT REQUIREMENTS OF FLOOR NOTES ON THE COVER SHEET (CS). GENERAL CONTRACTOR FINISH, FLOOR MATERIALS AND ASSOCIATED ADHESIVES. RESPONSIBLE TO COORDINATE W/ ALL SUB CONTRACTORS. ALL INFORMATION SHALL BE PROVIDED AND REVIEWED BY ARCHITECT 4. CONCRETE FLOOR TO BE PREPPED TO ACCEPT DIRECT APPLIED FLOOR FINISH AND AND LANDLORD PRIOR TO FINAL DRAW/ PAY REQUEST APPROVAL. FLOORING MATERIAL. COORDINATE W/ LANDLORD AND TENANT. FLOOR TO BE FREE OF DEFECTS AND HAVE A SMOOTH LEVEL FINISH. TENANT'S CONTRACTOR TO SUPPLY AND 14. GENERAL CONTRACTOR RESPONSIBLE TO CONDUCT WEEKLY TO INSTALL FLOOR FINISH AND FLOORING MATERIALS. BI-WEEKLY JOB SITE MEETINGS WITH ALL SUB CONTRACTORS ON SITE INCLUDING BOTH LANDLORDS AND TENANTS CONTRACTORS IF 5. ALL CONCRETE (SITE, FLOOR, ETC.) TO HAVE CYLINDER SLUMP TEST PER 30 YDS DIFFERENT. GENERAL CONTRACTOR TO ALSO TAKE WEEKLY MIX FOR OWNER, ARCHITECT AND ENGINEER REVIEW. JOBSITE MEETING MINUTES AND PROGRESS PHOTOS TO BE DISPERSED TO ALL CONTRACTORS, ARCHITECTS, ENGINEERS, 6. GENERAL CONTRACTOR/ CONCRETE CONTRACTOR TO CONTACT OWNER -LANDLORD, LANDLORD AND TENANT. ARCHITECT OR ENGINEER ONE DAY PRIOR TO CONCRETE POUR TO REVIEW AGGREGATE BASE. BASED ON SITE LOCATION THIS MAY BE REVIEWED VIA SITE PHOTOS. 15. GENERAL CONTRACTOR TO DISPERSE ALL PLANS, ADDENDUMS AND CONSTRUCTION BULLETINS TO ALL BIDDERS AND SUB 7. AT NEW SLAB POURS THAT CONNECT TO EXISTING SLABS. CONTRACTOR SHALL DRILL CONTRACTORS. GENERAL CONTRACTOR RESPONSIBLE TO MAINTAIN AND DRIVE 5/8" DIA. SMOOTH ROD @ 18" O.C. MIN. RODS SHALL BE 16" LONG W/ 8" A PLAN HOLDERS LIST/ LOG. GENERAL CONTRACTOR TO HAND EMBED. TIE TO WIRE MESH REINFORCEMENT (TYP.). COAT ONE END OF ROD TO PREVENT OUT FULL SETS OF PLANS TO EACH CONTRACTOR NO PARTIAL BONDING W/ SLAB. PRINTING WILL BE ACCEPTED. 8. GENERAL CONTRACTOR TO PROTECT ALL CONCRETE SURFACES FROM OILS AND GENERAL ROOM FINISH NOTES: STAINS. THERE WILL BE NO WRITING ALLOWED ON EXPOSED SLABS. 1. ALL GYP. BOARD SURFACES SHALL BE LEVEL 4 GRADE FINISH 9• COVER NEWLY PLACED SLAB W/ POLY TO CONTROL MOISTURE CONTENT AND , AND GYP. BD. SURFACES SHALL BE TAPED, MUDDED AND FACILITATE EVEN CURING THROUGHOUT. PRIMED TO ACCEPT TENANT FINISHES. COORDINATE FINAL FINISH MATERIAL AND COLORS WITH FINISH PLAN. SPRAYED 10. COORDINATE SLAB SAWCUT JOINTS W/ ORIGINAL BUILDING PLANS. IF PLANS DO NOT ON PAINT AND BACK ROLL FOR TEXTURE. WALL FINISH TO BE NOTE SAWCUT JOINTS, MATCH EXISTING CONCRETE SAWCUT JOINTS. IF NO EXISTING MAINTAINED OVER ENTIRE WALL SURFACE FROM THE FLOOR TO SAWCUT JOINTS, MAINTAIN 15' x 15' SAWCUT JOINT GRID (TYP.) A MIN. OF 6" ABOVE FINISH CEILING HEIGHT. COORDINATE WITH SUPPLIED BASE TYPE/ HT. GENERAL DOOR/HARDWARE NOTES: 2. ALL EXPOSED BLOCK WALLS SHALL BE PREPPED, BLOCK FILLER/ PRIMER APPLIED AND FINISHED WITH TWO (2) COATS 1. HARDWARE LOCK KEYING - PAINT. HARDWARE SUPPLIER TO PROVIDE LOCK SCHEDULE, KEY DIAGRAM AND HAVE A 3. PAINT EXPOSED STRUCTURE, MECHANICAL, AND REPRESENTATIVE GO OVER BUILDING KEYING DIRECT W/ OWNER -LANDLORD AND TENANT. ELECTRICAL EQUIPMENT TO MATCH COLOR OF THE KEYS TO BE HANDED DIRECT TO OWNER/TENNANT. ADJACENT WALLS (EXCEPT FACTORY FINISHED FIXTURES). 2. ALL CYLINDERS TO BE SCHLAGE HEAVY DUTY'D' SERIES FULL SIZE W/ 4. FLOOR FINISH MATERIALS SHALL BE COORDINATED WITH TENANT INTERCHANGEABLE CORES. NO SUBSTITUTIONS. AND INSTALLED PER PLANS. 3. FINAL CORES TO BE COORDINATED W/ OWNER -LANDLORD &TENANT. 5. ALL MTL. STUD FRAMED SOFFITS TO HAVE DIAGONAL BRACING AS 4. ALL HOLLOW METAL DOORS/FRAMES SHALL BE WELDED - NO KNOCK DOWN FRAMES REQUIRED FOR STABILITY AND GYP. BD. ALL SIDES TO MIN. 6" PERMITTED UNLESS SPECIFICALLY NOTED. ABOVE ADJACENT FINISH CLG. HEIGHT. 5. ALL HARDWARE TO BE AMERICANS WITH DISABILITIES ACT (A.D.A.) COMPLIANT 6. ALL CEILING GRIDS SHALL BE CENTERED IN EACH ROOM UNLESS OTHERWISE NOTED, SEE REFLECTED CEILING PLAN. 6. ALL TOILET ROOM DOORS TO HAVE A CLOSER AND PRIVACY LOCK, SEE HARDWARE SCHEDULE FOR ADDITIONAL NOTES. 7. ALL ELECTRICAL AND MECHANICAL FIXTURES TO BE INSTALLED WITHIN CEILING SHALL BE CENTERED ON CEILING TILE UNLESS NOTED OTHERWISE, SEE MEP DRAWINGS. 7. PROPER EXIT HARDWARE IS REQUIRED ON ALL EXIT AND EXIT ACCESS DOORS. DEAD BOLT HARDWARE SHALL COMPLY WITH REQUIREMENTS OF THE 2003 INTERNATIONAL BUILDING CODE. 8. ANY LOCATION GYP. BD. CONTACTING DISSIMILAR MATERIAL PROVIDE SEALANT JOINT PRIOR TO PAINT/ FINISH MATERIAL, TYP. 8. ALL HARDWARE TO BE SCHLAGE OR EQUAL. CYLINDERS TO BE HEAVY DUTY. ALL FINISHES TO BE BID AS 626 SATIN CHROME FINISH, UNLESS NOTED OTHERWISE. 9. PROVIDE THE FOLLOWING AT WALL TO FRAME/ GLASS TERMINATION. COORDINATE FINAL HARDWARE COLOR/FINISH W/ OWNER -LANDLORD, ARCHITECT AND ALIGN NEW WALL WITH CENTER OF EXIST. WINDOW MULL TYPICAL, TENANT PRIOR TO ORDERING/INSTALLATION. STEP WALL AT WINDOW SILL/ HEAD. PROVIDE VINYL'J' TRIM CLOSURE TO WINDOW FRAME TYPICAL, PROVIDE CONT. SEALANT JOINT. PROVIDE BREAK MTL. CLOSURE TO MATCH WINDOW FRAME AT g ENTRY DOORS TO HAVE PASSAGE/ENTRY LOCKSET W/ CLOSER, COORDINATE W/ TENANT. FACE OF WALL EXPOSED TO FRONT OF STORE FRONT. 10. AT RATED ROOMS HARDWARE SUPPLIER TO PROVIDE PROPER LOCKS, CLOSERS, ECT. TO MEET CODE. 10. AT HOLLOW METAL OR ALUMINUM FRAMES (IE: WINDOW/ DOORS) PLACED IN GYP BD WALL ASSEMBLIES. RETURN GYP. BD. TO 11. HARDWARE SUPPLIER TO PROVIDE DOOR STOPS AT ALL DOORS. (IE WALL STOP, HINGE FRAME, PROVIDE PLASTIC'J' CHANNEL AND SEALANT TYP. STOP, FLOOR STOP OR OVERHEAD.) THESE STOPS TO BE PROVIDED IN THIS ORDER WITH ENTIRE FRAME. WALL STOPS AS PREFERRED APPLICATION. SEE HARDWARE SCHEDULE FOR NOTES. 11. IF GYP. BD. IS STOPPED SHORT OF STRUCTURE ABOVE. INSULATION CONTRACTOR TO PROVIDE STRAPPING AT 24" O/C VERTICAL AND SPRAY INSULATION TO BE USED AT THE CAVITY TO PREVENT INSULATION SLUMPING. 13. FLOORING CONTRACTOR TO PROVIDE COLOR MATCHED CAULK TO FLOOR TILE FINISH (IE: CERAMIC, VCT) AT ALL FLOOR DRAINS AND CLEAN OUTS. FINISH NOTES: 1. INTERIOR WALL & CEILING FINISHES SHALL COMPLY W/IBC 803.5. 803.5 INTERIOR FINISH REQUIREMENTS BASED ON GROUP. INTERIOR WALL AND CEILING FINISH SHALL HAVE A FLAME SPREAD INDEX NOT GREATER THAN THAT SPECIFIED IN TABLE 803.5 FOR THE GROUP AND LOCATION DESIGNATED. INTERIOR WALL AND CEILING FINISH MATERIALS, OTHER THAN TEXTILES, TESTED IN ACCORDANCE WITH NFPA 286 AND MEETING THE ACCEPTANCE CRITERIA OF SECTION 803.2.1, SHALL BE PERMITTED TO BE USED WHERE A CLASS A CLASSIFICATION IN ACCORDANCE WITH ASTM E 84 IS REQUIRED. EXIT ENCLOSURES & EXIT PASSAGEWAYS - CLASS B INTERIOR FINISH MATERIALS CORRIDORS, ROOMS & ENCLOSED SPACES - CLASS C INTERIOR FINISH MATERIALS LAVATORY SHALL NOT ENCROACH INTO CLEAR FLOOR SPACE OF WATER CLOSET (TYP.) 7'-1 119" 1 RESTROOM 1 A5.0 SCALE: 1/4" = V-0" 7'-9 1 /9" 2 RESTROOM 2 A5.0 SCALE: 1/4" = V-0" 16X28.75X24 2D1FD BASE CAB AD-RD-01-AOO fV --f I t 10'-2" FINISH GYP. OPENING 4 A5.0 RECEPTION DESK PLAN DETAIL SCALE: 3/8" = V-0" 1 5 RECEPTION DESK DETAIL A5.0 SCALE: 1/2" = V-0" GENERAL HVAC NOTES: 11 2'-0" 1. ONE DIGITAL THERMOSTAT WITH RELATED LOW VOLTAGE WIRING PER HVAC TYP. UNIT/ZONE. SEE HVAC DRAWINGS. 2. ALL GAS PIPING TO BE RUN FROM METER DIRECT TO INTERIOR NO GAS PIPE TO RUN UP EXTERIOR WALLS. ALL GAS PIPING MUST BE PRIMED AND - _- PAINTED TYPICAL. 3. INSULATE ALL NECESSARY DUCTWORK AND PIPING PER CODE. 4. SUPPLY AND INSTALL ALL NECESSARY EXHAUST FANS, DUCTWORK, VOLUME MICROWAVE DAMPERS, GRILLES, REGISTERS AND LINEAR DIFFUSERS PER CODE. -t 5. PROVIDE AIR BALANCING OF THE ENTIRE SPACE BY PROVIDING FULL B TESTING AND BALANCING REPORT, FOR LANDLORD & TENANT REVIEW. z - 6. PROVIDE ALL STATE & LOCAL PERMITS AND ANY OTHER TRADE RELATED FEES. O - 7. AT RATED ROOMS CONTRACTOR TO PROVIDE DUCT FIRE DAMPERS AS U iv REQUIRED BY CODE TYPICAL. THIS WOULD ALSO APPLY TO ANY PIPE PENETRATIONS THAT WILL BE REQUIRED TO BE FIRE CAULKED OR SLEEVED TYPICAL. 0 8. SEE LANDLORD NOTES ON SHEET T2.0 FOR ADDITIONAL INFORMATION 1'- PLUMBING NOTES: DOORS W/ INTEGRAL - KICK SPACE, TO OPEN 1. PROVIDE SEPARATE WATER METER FOR TENANT SPACE, TYPICAL, COORDINATE CLEAR FOR H/C ACCESS W/ BUILDING OWNER/LANDLORD AND PLUMBING DRAWINGS. -INSULATE PIPES 2 ALL PLUMBING FIXTURES TO MEET ADA GUIDELINES AND STATE/LOCAL CODES 2'-0" ELEVATION - RECEPTION SCALE: 3/8" =1'-0" 9 -v L OPEN 7, OPEN FILE FILE 7 FINISH FLOOR LINE MODESTY PANEL MODESTY PANEL 6� ELEVATION - BUSINESS OFFICE SCALE: 3/8" = V-0" NOTE: CASEWORK LAYOUT TO BE COORDINATED W/ASPEN DENTAL 4 a MILWORK SUPPLIER fV ALL BASE CABS ARE 24" DEEP I I I I OPEN II \ I FOR I \ - I FRIDGE I \ / L---J T-0" I1, 2'-0" AND ORDINANCES. 7 ELEVATION - STAFF LOUNGE 3. ALL ROOF DRAIN LEADERS AND OVERFLOW PIPING TO BE WRAPPED IN PIPE A5.0 SCALE: 3/8" = 1'-0" INSULATION ALL AREAS NO EXCEPTIONS. 4. PROVIDE ALL STATE & LOCAL PERMITS AND ANY OTHER TRADE RELATED FEES. 5. ALL WATER PIPING WILL BE TYPE L COPPER AND WILL CONNECT TO EXISTING, SEE PLUMBING DRAWINGS FOR ADDITIONAL INFO. 6. ALL DRAIN PIPING WILL BE PVC PLASTIC AND WILL CONNECT TO EXISTING, SEE PLUMBING DRAWINGS FOR ADDITIONAL INFO. 7. AT RATED ROOMS CONTRACTOR TO PROVIDE FIRE CAULKING OR SLEEVE PIPING AS REQUIRED BY CODE TYPICAL. 8. SEE LANDLORD NOTES ON SHEET T2.0 FOR ADDITIONAL INFORMATION 9'-0" ELECTRICAL NOTES: 4'-6" 4'-6- 1 PROVIDE SEPARATE METERED, DEDICATED SERVICE AND PANEL PER TENANT 6" 6" ELECTRICAL DRAWINGS. 1/2" GAS LINE REDUCED TO 3/8" FMT ON RT OF 3" 2. COORDINATE PANEUSUB PANEL LOCATION W/ LANDLORD/TENANT IF 1 1/4" TABLE -TERMINATE PER o LOCATED WITHIN TENANT SPACE. DETAIL D-1343/MD 3. COORDINATE ALL POWER, PHONE AND DATA REQUIREMENTS W/ TENANT. 1 1/2" COPPER AIR 1 1/2" COPPER AIR -� LINE AT 24" AFF LINE AT 24" AFF 4. COORDINATE PHONE SERVICE INSTALL REQUIREMENTS W/ TENANT. VERIFY o o PANEL LOCATION W/ TENANT AND TENANT DRAWINGS TYP. ®® -TERMINATE PER m® -TERMINATE PER mm ®® DETAIL D-13A/MD K DETAIL D-13AIMD m 5. ALL WIRING TO BE INSTALLED IN CONDUIT, TYPICAL iv � � 6. IN PATIENT ROOMS/AREAS ALL ELECTRICAL REQUIRES REDUNDANT GROUNDING. 1/2"iii QUAD OUTLET � � SEE ELECTICAL QUAD OUTLET �q SEE ELECTICAL 7. AT RATED ROOMS CONTRACTOR TO PROVIDE FIRE CAULKING OR SLEEVE CLR. PLANS CLR. PLANS PIPING AS REQUIRED BY CODE TYPICAL. FINISH FLOOR LINE 8. PROVIDE ALL STATE & LOCAL PERMITS AND ANY OTHER TRADE RELATED FEES. 9 W1 PULL WIRE TO PULL DINATE OEE ELEVATION - LAB WORKSTATION SIZUIT FOR E TELEPHONE COO. USE. COORDR OFOCONDU TB TELEPHONE PROVIDER. s A5.0 10. G.C. TO PROVIDE MIN. 1/2" PLYWOOD PANEL. COO_ RDINATE REQUIRED SCALE: 1/2" = 1'-0" LOCATIONS W/ TENANT. 11. ELEC. CONTRACTOR RESPONSIBLE FOR COORDINATING TELEPHONE PANEUEQUIPMENT LOCATIONS W/ TELEPHONE CO. 12. SEE LANDLORD NOTES ON SHEET T2.0 FOR ADDITIONAL INFORMATION EXCEL ENGINEERINGInc. 100 CAMELOT DRIVE FOND DU LAC, WI 54935 PHONE: (920) 926-9e00 FAX: (920) 926Ae01 Always a Better Plan Lf� O � Q I- z W Q O W W CD Q > > Z Q W LLJ W Z U LLj Q V) V) D .. ~ cl:f W U Q LJv Q N Z Lw C (n (n 00 Q O Q N W Q I N W H- W V) f- 7-0 O � W U J M m W � � J J � J J cn Q ..Q CD z J r- J U W I J W of 0 W = _ W W O W (n W I-, LIJ Q N I1- N SHEET ISSUE: NOVEMBER 23, 2009 SEE TITLE SHEET TO CONFIM THAT THIS SHEET HAS BEEN ISSUED FOR CONSTRUCTION REVISIONS: SEE PLAN r-=-�_ __- - - j KEYBOARD & LCD iv II MONITOR II LL-- ---I-- --� N PRINTER J BOX OR PLASTER RING @ 18" A.F.F. 1"o CONDUIT N ABOVE CEILING o 0 m m I I o I I � 2"o CONDUIT i CPU N ABOVE CEILING I i I QUAD OUTLET `---J - FINISH FI ELEVATION - ALCOVE SCALE: 1/2" = 1'-0" I � i I I CLEAR FLOOR L__-1 SPACE "30 MIN. 17" - 19" 3" MAX. EQUIP. ONLY PERMITTED IN SHADED AREA H X U = z z co a 04 cn CV 8" 6" MIN. MAX. " CONTROLS MUST BE MOUNTED IN FRONT OR SIDE MOUNTED NEAR FRONT EDGE " PROVIDE CUP DISPENSER FOR NON -WHEELCHAIR USERS. 10 E.W.C. DETAIL A5.0 SCALE: 1/4" = 1'-0" GENERAL ACCESSIBILITY NOTES GYP. BD. RETURNS @ SIDES @ TOP INSTALL TOP TRACK OF SLIDING PASS THRU WINDOW TO BOT. SIDE OF GYP. BD. -FINISH CAULK EA. SIDE 1/4" FROSTED GLASS W/ BEVELED HAND GRIP INSTALL BOTTOM TRACK OF SLIDING PASS THRU WINDOW IN 1 3/16" x 9/16" DADO CUT INTO TOP OF PLASTIC LAMINATE CAP -FINISH CAULK EA. SIDE 1 1/4" PLASTIC LAMINATE CAP BY MILLWORK SUPPLIER MTL. STUD -SEE PLAN FOR SIZE PASS THRU DETAIL SCALE: 3" = V-0" PROVIDE BLOCKING IN WALL AS REQ'D TO ANCHOR MOUNTING BRACKET (TYP.) FINISH FLOOR LINE a c is u FIRE EXTINGUISHER SPECIFICATION: MANUFACTURER: JL INDUSTRIES, INC. PRODUCT: FIRE EXTINGUISHER: -'COSMIC' 10E 10 Ib. CAPACITY; 4A-80BC RATING BRACKET: - MARK 'MB846' WALL BRACKET FIRE EXTINGUISHER DETAIL SCALE: 1/2" = V-0" c c WALL CONST. - SEE WALL TYPES BUILD WALL TIGHT TO EXIST. FRAME CONT. ALUM. TRIM EACH SIDE c ALUMINUM TUBE - VERIFY DEPTH EXIST. WINDOW FRAME BELOW WALL CLOSURE DETAIL SCALE: 1 1/2" = V-0" X-RAY SUPPORT TO WITHSTAND 450 LBS. OF WITHDRAW FORCE AND 100 LBS. OF SHEAR AT EA. BOLT LOCATION. INSTALLATION BEHIND FINISHED SURFACES. FOLLOW ANY AND ALL VARIATIONS REQUIRED FOR LOCAL BUILDING AND X-RAY RADIATION CONTROL STANDARDS. 4x4 POST (6) #12 WIRES RAN TO MASTER CONTROL, LOCATED OUTSIDE OF X-RAY ROOM SEE DETAIL D9A ON SHEET MD :RRIFY WALL RATING IF 'PLICABLE. PROVIDE FIRE IEATED BLOCKING AS REQ'D 3/4" PLYWOOD 44 JBOX MOUNTED @ 42" A.F.F. TO BOTTOM,CENTERED BETWEEN 4x4 POST 5/8" GWB BOTH SIDES DOUBLE GWB INSIDE OF ROOM BELMONT 096 X-RAY SUPPORT SCALE: 1/2" = V-0" RUN WIDTH OF WALL i ifl VERRIFY WALL RATING IF APPLICABLE. PROVIDE FIRE TREATED BLOCKING AS REQ'D (2) LAYERS 3/4" PLYWOOD 20 GAUGE STEEL WALL STUDS (16" O.C.) DEDICATED 20 AMP 220V ELEC. CIRCUIT TWIST LOCK OUTLET (ELECTRICIAN TO SUPPLY MALE END) (CENTERED IN ROOM) PLASTER RING WITH 2" CONDUIT OR WALL CHASE RAN ABOVE CEILING WITH PULL STRING (CENTERED IN ROOM) 5/8" GWB BOTH SIDES DOUBLE GWB INSIDE OF ROOM PANORAMIC X-RAY SUPPORT SCALE: 1/2" = V-0" RUN WIDTH OF WALL i NZE, 0 Lo PLASMA TV SUPPORT SCALE: 1/2" = V-0" VERRIFY WALL RATING IF APPLICABLE. PROVIDE FIRE TREATED BLOCKING AS REQ'D (2) LAYERS 3/4" PLYWOOD 20 GAUGE STEEL WALL STUDS (16" O.C.) PLASTIC JBOX AND PLASTER RING AND PULL STRING ABOVE CEILING. - SEE ELECTRICAL PLANS DUPLEX ELECTRICAL OUTLET -SEE ELECTRICAL PLANS 5/8" GWB BOTH SIDES DOUBLE GWB INSIDE OF ROOM THRESHOLDS 1. FLOOR(S) OR LANDING(S) ARE NOT MORE THAN 1/2" LOWER THAN THE TOP OF THE THRESHOLD OF THE DOORWAY. 2. PER 303.3 CHANGE IN LEVEL BETWEEN 1/4" AND 1/2" IS BEVELED AT A GRADIENT NOT TO EXCEED 1:2 3. DOORMATS ARE SECURELY ATTACHED (ANCHORED OR RECESSED) AND HAVE A LEVEL LOOP, LEVEL CUT/UNCUT PILE WITH PILE NOT EXCEEDING 1/2" IN HEIGHT. 4. EXPOSED EDGES OF DOORMAT(S) ARE FASTENED TO FLOOR SURFACES AND HAVE TRIM ALONG THE ENTIRE LENGTH OF THE EXPOSED EDGE. DOORS 1. MINIMUM OF 3'-0" IN WIDTH, 6-8" IN HEIGHT. 2. OPENS A MINIMUM OF 90 DEGREES. 3. CLEAR WIDTH OF THE DOORWAY IS 32" MINIMUM. 4. DOUBLE DOORS / AUTOMATIC DOORS AT LEAST ONE DOOR MUST COMPLY WITH 1, 2 AND 3 ABOVE. 5. BOTTOM 10" OF DOOR HAS A SMOOTH, UNINTERRUPTED SURFACE THAT ALLOWS DOOR TO BE OPENED BY A WHEELCHAIR FOOTREST WITHOUT CREATING A TRAP OR HAZARDOUS CONDITION. NOTE: WHERE NARROW FRAME DOORS ARE USED A 10" HIGH SMOOTH PANEL MUST BE INSTALLED ON THE PUSH SIDE BOTTOM OF THE DOOR WHICH WILL ALLOW THE DOOR TO BE OPENED BY A WHEELCHAIR FOOTREST WITHOUT CREATING A TRAP OR HAZARDOUS CONDITION. 6. EFFORT TO OPERATE DOORS IS WITHIN PRESSURES ALLOWED. INTERIOR DOORS 5 POUNDS MAXIMUM PRESSURE TO OPERATE. FIRE DOORS SEE APPROPRIATE ADMINISTRATIVE AUTHORITY. 7. TWO DOORS IN A SERIES PROVIDE A MINIMUM OF 48" CLEAR SPACE FROM ANY DOOR, IN ANY POSITION. DOOR HARDWARE 1. EXIT DOORS ARE OPERABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT. 2. LATCHING AND LOCKING DOORS THAT ARE HAND OPERATED ARE OPERABLE WITH A SINGLE EFFORT (EX. LEVER TYPE, PANIC BARS OR PUSH-PULL TYPE). 3. OPENING HARDWARE IS NO HIGHER THAN 48 ABOVE FINISH FLOOR. 4. DOOR CLOSER SHALL BE ADJUSTED SO THAT FROM AN OPEN POSITION OF 90 DEGREES, THE TIME REQUIRED TO MOVE THE DOOR TO AN OPEN POSITION OF 12 DEGREES SHALL BE 5 SECONDS MINIMUM. 5. HANDLES, PULL, LATCHES, LOCKS AND OTHER OPERATING DEVICES ON ACCESSIBLE DOORS SHALL HAVE A SHAPE THAT IS EASY TO GRASP WITH ONE HAND AND DOES NOT REQUIRE TIGHT GRASPING, TIGHT PINCHING, OR TWISTING OF THE WRIST TO OPERATE. LEVER OPERATED MECHANISMS, PUSH -TYPE MECHANISMS, AND U- SHAPED HANDLES ARE ACCEPTABLE DESIGNS. WHEN SLIDING DOORS ARE FULLY OPEN, OPERATING HARDWARE SHALL BE EXPOSED AND USABLE FROM BOTH SIDES. HARDWARE REQUIRED FOR ACCESSIBLE DOOR PASSAGE SHALL BE MOUNTED NO HIGHER THAN 48 INCHES A.F.F. CLEAR SPACE AT DOORS GENERAL REGARDLESS OF THE OCCUPANT LOAD, THERE SHALL BE A FLOOR OR LANDING ON EACH SIDE OF A DOOR. 1. FLOOR OR LANDING ON EACH SIDE OF THE DOOR IS LEVEL AND CLEAR. 2. LEVEL AREA IN THE DIRECTION OF THE DOOR SWING IS A MINIMUM OF 60" IN LENGTH. 3. LEVEL AREA OPPOSITE THE DIRECTION OF THE DOOR SWING IS A MINIMUM OF 42-48" IN LENGTH, DEPENDING UPON DIRECTION OF APPROACH AND EXISTENCE OF LATCH AND CLOSER. 4. SURFACE SLOPE OF THE LEVEL AREA DOES NOT EXCEED 1:50 GRADIENT (2%). 5. MINIMUM STRIKE SIDE CLEARANCE ON PULL SIDE OF DOOR IS PROVIDED AT LANDING (PER 404.2.3.1). 6. MINIMUM LATCH SIDE CLEARANCE ON PUSH SIDE OF DOOR IS PROVIDED AT LANDING (PER 404.2.3.1). IDENTIFICATION SYMBOLS (FOR SANITARY FACILITIES) 1. THE INTERNATIONAL SYMBOL OF ACCESSIBILITY IS INSTALLED ON THE WALL ADJACENT TO THE LATCH SIDE OF THE DOOR. THE BORDER DIMENSIONS OF THIS PICTOGRAM SHALL BE A MINIMUM OF 6" IN HEIGHT. NOTE: WHERE THERE IS NO WALL SPACE ON THE LATCH SIDE, INCLUDING AT DOUBLE LEAF DOORS; SIGNS SHALL BE PLACED ON THE NEAREST ADJACENT WALL, PREFERABLY 2. VERBAL DESCRIPTION AS TO RESTROOM USAGE (I.E. MENS RESTROOM, ECT.) IS PLACED DIRECTLY BELOW THE SYMBOL OF ACCESSIBILITY. 3. THE CHARACTERS AND BACKGROUND OF THE SIGN IS EGGSHELL, MATTE OR OTHER NON -GLARE FINISH AND THE COLOR AND CONTRAST OF THE SIGN DISTINCTIVELY CONTRASTS WITH THE COLOR AND CONTRAST OF THE WALL. NOTE: THE REQUIRED COLOR OF THE SYMBOL OF ACCESSIBILITY CONSISTS OF A WHITE FIGURE ON A BLUE BACKGROUND. HOWEVER, THE APPROPRIATE ENFORCEMENT AGENCY MAY APPROVE SPECIAL SIGNS TO COMPLIMENT DECOR WHEN SUCH SIGNS PROVIDE ADEQUATE DIRECTION TO INDIVIDUALS WITH DISABILITIES. 4. SIGNS ARE CENTERED ON THE WALL 60" A.F.F. AND 8" FROM EDGE OF SIGN TO EDGE OF DOOR FRAME. 5. LETTERS AND NUMERALS ARE RAISED 1/32" ARE SANSSERIF UPPERCASE CHARACTERS AND ARE ACCOMPANIED BY GRADE 2 BRAILLE. CHARACTERS ARE A MINIMUM 5/8" HIGH AND A MAXIMUM OF 2" HIGH. 6. MOUNTING LOCATION ALLOWS A PERSON TO APPROACH WITHIN 3" OF THE SIGNAGE WITHOUT ENCOUNTERING PROTRUDING OBJECTS OR STANDING WITHIN THE SWING OF A DOOR. 7. SIGNS CONTAINING TACTILE CHARACTERS SHALL BE LOCATED SO THAT A CLEAR FLOOR AREA 18" X 18" MINIMUM, CENTERED ON THE TACTILE CHARACTERS, IS PROVIDED BEYOND THE ARC OF ANY DOOR SWING THE CLOSED POSITION AND 45 DEGREE OPEN POSITION. SANITATION FACILITIES 1. ACCESSIBLE UNITS SHALL BE IDENTIFIED BY THE INTERNATIONAL SYMBOL OF ACCESSIBILITY. 2. EXCEPT AT DOORS, THE MINIMUM CLEAR WIDTH OF AN ACCESSIBLE ROUTE IN FACILITY IS 36". 3. ENTRY DOOR HAS PUSH AND PULL FUNCTION (NO LATCHING DEVICE) WITH CLOSER. 4. SUFFICIENT SPACE FOR WHEELCHAIR MEASURING 30" X 48" TO ENTER ROOM AND PERMIT THE DOOR TO CLOSE IS PROVIDED. 5. A CLEAR SPACE OF SUFFICIENT SIZE TO INSCRIBE A 60" DIAMETER CIRCLE IS PROVIDED WITHIN THE SANITARY FACILITY ROOM. 6. 60" SPACE IS CLEAR OF OBJECTS FROM THE FLOOR TO A HEIGHT OF 27". 7. CLEAR FLOOR SPACE FOR WATER CLOSETS IN STALLS SHALL COMPLY WITH DIAGRAMS ON THIS SHEET. CLEAR FLOOR SPACE MAY BE ARRANGED TO ALLOW EITHER A RIGHT HANDED OR A LEFT HANDED APPROACH. 8. 18 BETWEEN CENTER OF WATER CLOSET AND SIDE -WALL CORNER. 9. TOILET SEATS SHALL NOT BE SPRUNG TO RETURN TO A LIFTED POSITION. 10. TOP OF TOILET SEAT IS 17"-19" FROM FLOOR SURFACE. 11. FLUSH VALVE IS ON WIDE SIDE OF TOILET AREA. 12. 44" MAXIMUM FROM FLOOR TO FLUSH VALVE. 13. 5 LB. MAXIMUM FORCE TO OPERATE FLUSH VALVE. 14. WALLS WITHIN COMPARTMENT ARE SMOOTH, HARD AND NONABSORBENT TO 48 IN HEIGHT AND ARE NOT ADVERSELY AFFECTED BY MOISTURE. 15. FLOOR SURFACES OF TOILET ROOM ARE SMOOTH, HARD AND NON-ABSORBANT. BASE SHALL EXTEND UPWARD A MINIMUM OF 6" ONTO WALLS. 16. SIDE GRAB BAR IS A MINIMUM OF 42" LONG. 17. THE FORWARD END OF THE GRAB BAR IS LOCATED A MINIMUM OF 54" FROM THE BACK WALL. 18. SIDE GRAB BAR BEGINS A MAXIMUM OF 12" FROM THE REAR WALL. 19. REAR GRAB BAR IS A MINIMUM 48" LONG WITH THE ADDITIONAL LENGTH PROVIDED ON THE TRANSFER SIDE OF THE WATER CLOSET. 20. REAR GRAB BAR BEGINS A MAXIMUM OF 6" FROM THE CORNER OF THE WALL ON THE TOILET SIDE. 21. DIAMETER OF THE GRAB BAR(S) IS 1 1/4" -1 1/2" OR SHAPE PROVIDES EQUIVALENT GRIPPING SURFACE. 22. CLEARANCE BETWEEN THE GRAB BAR(S) AND WALL IS 1 1/2" AND PARALLEL TO FLOOR (FOR TANK TYPE TOILETS, 36" MAY BE ALLOWED IF TANK OBSTRUCTS PLACEMENT OF BAR). 23. GRAB BARS ARE MOUNTED AT 33" TO CENTER OF BAR ABOVE. 24. BARS ARE SMOOTH WITH A MINIMUM RADIUS OF 1/8". 25. MINIMUM STRUCTURAL STRENGTH OF GRAB BAR(S) WILL SUPPORT A 250 LB. POINT LOAD. 26. GRAB BARS DO NOT ROTATE WITHIN THEIR FITTINGS. 27. SURFACE OF WALL ADJACENT TO GRAB BAR(S) IS FREE OF SHARP OR ABRASIVE ELEMENTS. 28. TOILET PAPER DISPENSERS SHALL COMPLY WITH SECTION 309.4 AND SHALL BE 7 MINIMUM AND 9 MAXIMUM IN FRONT OF THE WATER CLOSET MEASURED TO THE CENTER LINE OF THE DISPENSER. 29. THE OUTLET OF THE DISPENSER SHALL BE 14" MINIMUM AND 19" MAXIMUM ABOVE THE FLOOR. THERE SHALL BE A CLEARANCE OF 1 1/2" MINIMUM BELOW THE GRAB BAY. 30. DISPENSERS SHALL NOT BE A TYPE THAT CONTROL DELIVERY OR DO NOT ALLOW CONTINUOUS PAPER FLOW. LAVATORIES 1. MINIMUM 30" X 48" CLEAR SPACE IS PROVIDED IN FRONT OF LAVATORY THAT ALLOWS FORWARD APPROACH. 2. REQUIRED CLEAR SPACE ADJOINS OR OVERLAPS AN ACCESSIBLE ROUTE AND EXTENDS A MAXIMUM OF 19" UNDERNEATH THE LAVATORY. 3. 34" MAXIMUM HEIGHT OF RIM OR COUNTER ABOVE FLOOR SURFACE. 4. 29" MINIMUM CLEARANCE FROM BOTTOM OF APRON TO THE FLOOR. 5. KNEE CLEARANCE UNDER FRONT LIP IS A MINIMUM OF 27" HIGH, 30" WIDE, AND EXTENDS A MINIMUM OF 8" IN DEPTH FROM THE FRONT OF THE LAVATORY. 6. TOE CLEARANCE UNDER LAVATORY IS A MINIMUM OF 9" HIGH, 30" WIDE, AND EXTENDS A MINIMUM OF 17" IN DEPTH FROM THE FRONT OF THE LAVATORY. 7. DRAIN AND HOT WATER PIPING IS INSULATED OR CONFIGURED TO PREVENT CONTACT. 8. THERE ARE NO SHARP OR ABRASIVE ELEMENTS UNDER LAVATORY. 9. FAUCETS ARE LEVER TYPE, ELECTRONICALLY ACTIVATED OR APPROVED SELF CLOSING VALVES (MIN. 10 SECONDS OPEN FLOW). 10. FAUCETS ARE OPERABLE WITH ONE HAND AND DO NOT REQUIRE TIGHT GRASPING, PINCHING OR TWISTING OF THE WRIST. 11. 5 LB. MAXIMUM FORCE REQUIRED TO ACTIVATE CONTROLS. WATER CLOSETS 1. 30" WIDE X 48" DEEP MINIMUM CLEAR ACCESS IN FRONT OF FIXTURE (ONE FIXTURE ONLY REQUIRED). 2. ONE FULL UNOBSTRUCTED SIDE OF THE CLEAR FLOOR OR GROUND SPACE ADJOINS OR OVERLAPS AN ACCESSIBLE ROUTE OR ADJOINS ANOTHER WHEELCHAIR CLEAR FLOOR SPACE. 3. 44" MAXIMUM HEIGHT OF FLUSH VALVE ABOVE FLOOR. 4. 5 LB. MAXIMUM PRESSURE TO OPERATE FLUSH VALVE. 5. FLOOR SURFACES ARE SMOOTH, HARD AND NON -ABSORBENT EXTENDING UPWARD A MINIMUM OF 6" ONTO THE WALLS. 6. WALLS WITHIN 24" OF FRONT AND SIDES OF URINAL ARE SMOOTH, HARD AND NON - ABSORBENT TO 48" IN HEIGHT AND ARE NOT ADVERSELY AFFECTED BY MOISTURE. ACCESSORIES IN SANITARY FACILITIES 1. MINIMUM 30 X 48 CLEAR FLOOR OR GROUND SPACE IS PROVIDED TO ALLOW FORWARD OR PARALLEL APPROACH TO ACCESSORIES. 2. ONE FULL UNOBSTRUCTED SIDE OF THE CLEAR FLOOR OR GROUND SPACE ADJOINS OR OVERLAPS AN ACCESSIBLE ROUTE OR ADJOINS ANOTHER WHEELCHAIR CLEAR FLOOR SPACE. 3. MIRROR(S) IS MOUNTED WITH THE BOTTOM OF THE REFLECTIVE SURFACE EDGE NO HIGHER THAN 40" A.F.F. AND WITH THE TOP OF THE REFLECTIVE SURFACE EDGE NO LOWER THAN 74" A.F.F. 4. OPERABLE PARTS (INCLUDING COIN SLOTS) OF ALL FIXTURES OR ACCESSORIES ARE LOCATED A MAXIMUM OF 40" ABOVE FLOOR (I.E. SOAP DISPENSERS, TOWELS, TOILET SEAT COVERS, AUTO -DRYERS, SANITARY NAPKIN DISPENSERS, WASTE RECEPTACLES, ECT.). 5. CONTROLS AND OPERATING MECHANISMS ARE OPERABLE WITH ONE HAND AND DO NOT REQUIRE TIGHT GRASPING, PINCHING OR TWISTING OF THE WRIST. 6. THE FORCE TO ACTIVATE CONTROLS IS 5 LB. MAXIMUM. EXCEL ENGINEERINCInc. 100 CAMELOT DRIVE FOND DU LAC, WI 54935 PHONE: (920) 926-"W FAX: (920) 926.9801 Always a Better Plan L0 O >- V) Q Z jD:� W :2 ry Q O >- W W C Q >> > Z Q W W W z 12 f-Y U Lj Q (n z r W U Q �.. LL p Z i>-- LLJ Q cn Z w V) � cn DO Q O Q N W Q I N LLJ 1..1_ W D ~ Z L iJ 0 O "t U El:f m W W D J J J . . J Q cn a z J J U W J J W c) z p W = _ �'�/ L_L W in W W O � � W Q N I�_ N SHEET ISSUE: NOVEMBER 23, 2009 SEE TITLE SHEET TO CONFIM THAT THIS SHEET HAS BEEN ISSUED FOR CONSTRUCTION REVISIONS: DATE: NOV. 23, 2009 z JOB NUMBER: z 914790 w w Z SHEET z. w J w U A %5. 0 D0 ROOM FINISH SCHEDULE FLOOR TRANSITION DETAILS WALL COVERINGS DOOR STAIN COLOR: m Z C � ROOM NAME 0 O LL y m N J I 3 (� Z 0 � W 0 Z 0 101 RECEPTION LVT B1 PT#2 C1 10'-2" 102 MEN'S RESTROOM VCT B1 FRP/PT#2 C1 9'-0" 2. 103 PANORAMIC.X-RAY VCT- B1 PT#1 C1 9'-0" 104 INTRA-ORAL X-RAY VCT B1 PT#1 C1 9'-0" 105 BUSINESS OFFICE CPT B2 C1 9'-0" 1. 106 CONSULTATION CPT B2 C1 9'-0" 1. 107 CORRIDOR CPT B2 C1 9'-0" 1. 108 STORAGE VCT B1 PT#1 C1 9'-0" 109 TR#1 VCT 131 C1 9'-0" 1. 110 TR#2 VCT B1 C1 9'-0" 1. 111 TR#4 VCT B1 C1 9'-0" 1. 112 TR #5 VCT B1 C1 9'-0" 1. 113 TR #6 VCT 131 C1 9'-0" 1. 114 STERILIZATION VCT B1 PT#1 C1 9'-0" 115 LAB VCT B1 PT#1 C1 70" 116 TR #3 VCT B1NPT#l C1 9'-0" 1. 117 TR #7 VCT B1C1 9'-0" 1. 118 TR #8 VCT B1C1 9'-0" 1. 119 WOMEN'S RESTROOM VCT B1 C1 9'-0" 2. 120 STAFF LOUNGE VCT B1C1 9'-0" 1. 121 MECHANICAL ROOM VCT B1 C1 9'-0" 3. 122 STORAGE VCT B1C1 9'-0" ROOM FINISH REMARKS: 1.) SEE FINISH PLAN FOR WALL FINISHES IN THIS ROOM 2.) PROVIDE FRP TO 44" AFF ON ALL WALLS & PAINT THE REMAINDER OF WALL ABOVE PT#2 FRP SPECIFICATION: KEMLITE 84 IVORY 3.) PROVIDE FRP TO 42" AFF ON ALL WALLS & PAINT THE REMAINDER OF WALL ABOVE PT#1 FRP SPECIFICATION: KEMLITE 84 IVORY CEILING REMARKS C1 MATERIAL: 24"x48" ACOUSTICAL PANEL CEILING * ALL CEILING HEIGHTS ARE AS MANOR ARMSTRONG STATED OR 2" ABOVE WINDOWS ITEM: SECOND LOOK II #2767D FLOORING ASPEN DENTAL WILL PURCHASE ALL FLOORING THROUGH A NATIONAL ACCOUNT. (CARPET, WALK -OFF, LVT, VCT, COVE BASE, TRANSITIONS, GLUES) FOR THE JOB. TO RELEASE FLOORING PRODUCT, PLEASE CONTACT CARPET WHOLESALE INC. MR. PAUL KRAWCZYK AT (315) 422-1489 OR E-MAIL aspendental(@sposatofloorino.com (4) WEEKS PRIOR TO THE DATE NEEDED. RECEPTION AND OFFICE AREAS: CPT CARPET TILE: MOHAWK EVEREST CARPET LINE SMILES MC112 - 8556 STIRRING BLUE (CARPET SQUARES / TILES) (INSTALL STRAIGHT PATTERN. ALL ARROWS FACE SAME DIRECTION) WALK OFF CARPET: SHAW CONTRACT GROUP BON JOUR - WELCOME - 10123 BEIGE (CARPET SQUARES / TILES) (INSTALL STRAIGHT PATTERN. ALL ARROWS FACE SAME DIRECTION) LVT VINYL TILE: ARMSTRONG LVT LINE NATURAL CREATIONS EARTHCUTS - TP510 HAVEN STONE RUST BROWN (INSTALL STRAIGHT PATTERN) B2 COVE MOLDING: USE CARPET BASE IN ALL CARPET AREAS (INCLUDING AROUND MILLWORK) OPERATORY AREAS AND CORRIDORS: ARMSTRONG VINYL COMPOSITION TILE VCT TILE: STANDARD EXCELON, IMPERIAL TEXTURE (INSTALL QUARTER TURN PATTERN) 51946 GENTIAN BLUE (15%) 51866 LITTLE GREEN APPLE (15%) 51899 COOL WHITE (70%) 131 COVE MOLDING: (WALLS & MILLWORK) ROPPE P125 FIG MATCHMATES RUBBER BASE OR JOHNSONITE #80 FAWN RUBBER BASE 6" HIGH IN RESTROOMS NOTE: LEAVE ALL EXTRA TILES IN MECHANICAL ROOM AT END OF JOB VCT PATTERN 51899 COOL WHITE (70%) E E351866 LITTLE GREEN APPLE (15%) ■ 51946 GENTIAN BLUE (15%) CARPET CARPET/VCT VINYL TRANSITION STRIP VCT a(Mira '7� I SHERWIN WILLIAMS - SHERWIN WILLIAMS PRO -MAR 200 PAINT IN EGGSHELL FINISH (PT #1) MAIN COLOR - SW 6176 LIVEABLE GREEN] (PT #2) ACCENT COLOR SW 7728 SPROUT HOLLOW METAL DOOR & FRAME PAINT: DOOR & WINDOW FRAME SHERWIN WILLIAMS DTM ACRYLIC DEEP BASE 1 GAL MIX BAC COLORANT OZ 32 64 128 131-BLACK - 56 1 1 N1-RAW UMBER - 7 - - R2-MAROON - 11 - - Y3-DEEP GOLD - 52 1 1 FLOOR FINISH PLAN SCALE: 1/4" = 1'-0" ML CAMPBELL CUSTOM MIX COLOR IS: ASPEN CHERRY JUBILEE PURCHASE FROM ATLANTIC PLYWOOD (800)801-9213 x6211 CONTACT RICK NOTE: BOTTOM OF ALL SOFFITS & HEADERS TO BE WHITE Am Q EXCEL ENGINEERINGIrw- Always a Better Plan Lo O NO Q z cj:� W Q O w OL 0 Q Z Q W W W Z ry - U W < V) V) z IY W U Q W Q (n Z W V) � 0- (/) V) 00 Q O Q N W MI N W W V) F- 7-It O Ill C) m W DE OF 0L J DOOR AND D ---I L.L_ PAINT (n Q IABOVE . • _j Q 0 (n (f) U W J J W o 0 W = _ EL EL O a_ IL V) W I-, LLJ n Q N I1_ ICI SHEET ISSUE: NOVEMBER 23, 2009 SEE TITLE SHEET TO CONFIM THAT THIS SHEET HAS BEEN ISSUED FOR CONSTRUCTION REVISIONS: CEILING DETAILS I / I i � PROVIDE 45' STUD BRACE @ 4'- ° 0" O.C. (MIN.) AS REQ'D O / STUDS @ 16" O.C. FASTENED TO STRUCTURE ABOVE -SEE I I PLAN FOR STUD SIZE ACCOUSTICAL CEILING TILE IN SUSPENDED GRID I I I� 5/8" GYPSUM BOARD EXISTING STOREFRONT GLAZING IN EXISTING EXTERIOR WALL WINDOW BULKHEAD DETAIL NOT TO SCALE *NOT REFERENCED ON PLANS CEILING LEGEND 2x4 FLUORESCENT FIXTURE W/ ACRYLIC LENS BATHROOM EXHAUST FAN 6" DIA. BLACK MULTIGROOVE {Rr RECESSED CAN LIGHT W/ 75 YY R30 INCANDESCENT LAMP 2x2 FLUORESCENT FIXTURE W/ ACRYLIC LENS SUSPENDED ACOUSTIC TILE CEILING @ 9'-0" A.F.F., UNLESS OTHERWISE NOTED GYPSUM BOARD CEILING NIGHT LIGHT EXIT LIGHT Q� BATTERY BACK-UP I� EGRESS LIGHTING qe( EXIT LIGHT W/ BATTERY �C BACK-UP EGRESS LIGHTING LIGHTING NOTE: GENERAL SWITCH LOCATIONS & WIRING TO BE DETERMINED BY LIGHTING CONTRACTOR PER LOCAL CODE AND TO BE APPROVED BY ASPEN DENTAL. ALL CEILING & LIGHT SUPPORT WIRES TO BE HUNG FROM TOP CHORD OF JOIST SYSTEM. RECESSED FIXTURE NOTE: G.C. TO PROVIDE "TENTING" AT ALL RECESSED CAN FIXTURES AS REQUIRED BY THE MANUFACTURES WRITTEN INSTRUCTIONS INSURING THAT NO INSULATION TOUCHES THE FIXTURES. NOTE: SEE ROOM FINISH SCHEDULE FOR CEILING FINISH & HEIGHT L C \ \ PROVIDE 45° STUD BRACE @ 4'- \ I 0" O.C. (MIN.) AS REQ'D \ 1 1 \ \ STUDS @ 16" O.C. FASTENED a TO STRUCTURE ABOVE -SEE \ \ 1 PLAN FOR STUD SIZE \ o\ I z I I= � I I• 'v ACCOUSTICAL CEILING TILE I I „ IN SUSPENDED GRID 5/8" GYPSUM BOARD BULKHEAD DETAIL NOT TO SCALE *NOT REFERENCED ON PLANS PROVIDE 45' STUD BRACE @ 4'- 0" O.C. (MIN.) AS REQ'D STUDS @ 16" O.C. FASTENED TO STRUCTURE ABOVE -SEE PLAN FOR STUD SIZE ACCOUSTICAL CEILING TILE IN SUSPENDED GRID '\— 5/8" GYPSUM BOARD BULKHEAD DETAIL NOT TO SCALE *NOT REFERENCED ON PLANS HQUUM REFLECTED CEILING PLAN SCALE: 1/4" = V-0" 5/8" GYPSUM BOARD — OVER SOFFIT FRAMING @ 16" O.C. FASTENED TO STRUCTURE ABOVE I I / PROVIDE 45° STUD BRACE @ 1 1 0 / 4'-0" O.C. (MIN.) AS REQ'D I° 1 I I I I •- 1 1 I I I 1 SOFFIT DETAIL NOT TO SCALE *NOT REFERENCED ON PLANS ACCOUSTICAL CEILING TILE IN SUSPENDED GRID 5/8" GYPSUM BOARD Aa EXCEL ENGINEERINGI,c. 100 CAMELOT DRIVE FOND DU LAC, WI 54935 PHONE: (920) 926-9800 FAX: (920) 926-9801 Always a Better Plan Lr) Q� z � � LEI :2 ry Q I i I n 0 < z W ,_,_I Ld - Iz U LLj acne V) I— .. z L W U Q Ld C) 7 Li Q V) z Lij (n 00 Q O Q N LLJ 2" X 4" BOX AND WIRE E ELECTRICIP 2X4STI FLOOR (6) #12 WIRES CONNECT TO TO X-RAY HEAD INSIDE X-RAY ROOM 110V 20A DEDICATED CIRCUIT LOCATED AT MASTER CONTROL +60" HEAD CONTROL PROVIDED AND INSTALLED BY SULLIVAN-SCHEIN X—RAY HEAD CONTROL NOT TO SCALE AUTOCLAVE OUTLET SEPARATE CIRCUIT 20 n"n nnnv AUTOCLAVE PROVIDED & INSTALLED B' SULLIVAN-SC 44" A.F.F. OUTLET PROVIDED AND INSTALLED BY COI AUTOCLAVE OUTLET NOT TO SCALE (3) #18/3 AWG SHEILDED WIRES TO X-RAY BY ELECTRICIAN 1 2" X 4" BOX BY ELECTRICIAN COVER pl;; •P _j I: '• h 'I -1•- PLATE AND BUTTON 7-(; f '•F_ FLOOR __: . I - COVER PLATE AND BUTTON SUPPLIED & INSTALLED BY SULLIVAN-SCHEIN: WIRING & J BOX BY ELECTRICIAN X—RAY REMOTE SWITCH NOT TO SCALE GAS LINE STUBBED OUT OF WALL BY CONTRACTOR. LAE TABLE GAS PIPING BY MILLWORK VENDOR. CONTRACTOR TO MAKE FIN. CONECTIONS FROM THE W/ TO THE LAB TABLE. 3/8" FEMALE PIPE THREAD - 3/8" OUT FROM FINISHED WALL PROVIDED & INSTALLED BY ASPEN DENTAL LAB GAS VALVE NOT TO SCALE FLOOR BOX DETAIL NOT TO SCALE 13/16" DEEP TRIM RING FURNISHED WITH VALVE VALVE INSTALLED BY ASPEN DENTAL. (EX: NEVIN 207) BOX 1/2' Aio i 'Kim BY C 1/2" C-.... ... FINISHED WALL PROVIDED AND INSTALLED BY CONTRACTOR AIR VALVE NOT TO SCALE MODEL TRIMMER 115V. 15AM PS. BY ELECTRICIAN no TRIM RING FURNISHED WITH VALVE 3/8" COMPRESSION FITTING NOTE: WATER LINE FOR MODEL TRIMMER TO BE PLACED IN WALL. LINE IN COUNTERTOP WILL ONLY BE ALLOWED AT EXISTING CONDITIONS WHERE PIPE CANNOT BE PULLED THROUGH WALL ANGLE STOP OR BALL VALVE BY CONTRACTOR WITH 1/4" COMPRESSION FITTING COMPRESSION TEE SINK BACKFLOW PREVENTER-BY P.C. NOTE: EXACT LOCATION AND SINK SIDE MAY VARY. TO BE SPOTTED BY SULLIVAN-SCHEIN EQUIPMENT REP. PLASTER BACK FLOW PREVENTION -SEE PLUMBING PLANS R\_HUB OUTLET. D-16 MODEL TRIMMER MD NOT TO SCALE NOTE: REMOTE CONTROL FACE PLATE PROVIDED BY SULLIVAN-SCHEIN & INSTALLED BY CONTRACTOR. LOW VOLTAGE WIRING BY ELECTRICIAN REMOTE CONTROL PANEL NOT TO SCALE RE L 'TOR AIR LINE BY CONTRACTOF 1/2" OUT FROI .. ... . WALL & 44" FROM FINISHED FLOOR THIS FITTING IS IN LAB ONLY!!! TRIM RING WITH VALVE 'FMT AIR VALVE NOT TO SCALE FRONT VIEW QUAD OUTLET HOSPITAL GRADE IF CODE REQ. -BY PUMB. CONTR. WATEF TRIMM STANC SUPPL INSTAL PLUME DRAIN BASE( CABINI PLASTER TRAP NOT TO SCALE UTZ 13" 1/2" BALL VALVE SUPPLIED AND INSTALLED BY CONTRACTOR. VALVE INSTALLED 90 DEG TO WALL. FEMALE END TO BE REDUCED TO 1/4" PLASTER TRAP PROVIDED BY SULLIVAN-SCHEIN AND INSTALLED BY PLUMBER. 2X10 WOOD BLOCK TO REST THE PLASTER TRAP ON. DO NOT ATTACH TO BASE OF SINK CABINET. SIDE VIEW 1/2" COPPER AIR LINES TERMINATED WITH 1/2" MALE THREAD. INSTALL 1/2" FPT ANGLE STOP (VALVE) W/ 3/8" COMPRESSION FITTING -BY PUMBING CONTR. 2 x 4 PLASTER RING W/ 2" CONDUIT IN WALL OR IN THE FLOOR W/ PULL STRING. SEE DETAILS FOR EACH ROOM. -BY ELECTRICAL CONTRATOR 1 1/2" PVC SUCTION LINE REDUCED TO 1/2" FEMALE THREAD. SUCTION LINES TO BE RAN FLAT INSIDE WALLS AND UNDERGROUND WHERE WALLS ARE NOT DAVAILABLE TO SUCTION MACHINE IN MECH. ROOM. LINES ARE NOT TO RUN UPHILL!M ASK ASPEN DENTAL CONSTRUCTION FOR DETAILS. -BY PLUMBING CONTRACTOR TRIM RING & COVER FOR UTILITY CENTER SUPPLIED & INSTALLED BY SULLIVAN-SCHEIN. 0 FINISHED FLOOR UTILITY CENTER NOT TO SCALE ALL DENTAL EQUIPMENT TO BE UL LISTED ENGINEERINGLnc. 100 CAMELOT DRIVE FOND DU LAD, WI 54935 PHONE: (920) 926A800 FAX: (920) 926-9001 Always a Better Plan U) Q� Z � � W Q O W n 0 Q Z Q W � L`-J z U Lj Q V) V) D Iz U p >_ W Q V) Z W f- 0- T_ (f) U) 00 Q 0 Q cv W Q N W LJ cn Z , W O d- C) U __j m W r W J __j J cn Q .. Q 0 zJ J U W J M J LL] r) -r r-- >- Iz OW W IZ O W V) W I,, LLJ Q N I�_ N SHEET ISSUE: NOVEMBER 23, 2009 SEE TITLE SHEET TO CONFIM THAT THIS SHEET HAS BEEN ISSUED FOR CONSTRUCTION REVISIONS: DATE: NOV. 23, 2009 Z _ JOB NUMBER: 914790 W W Z` SHEET Z W J W U W MD0 0 0 N EXISTING MULTI -TENANT METERING EQUIPEMENT. ONELINE LEGEND = EXISTING TO REMAIN = NEW DEMOLISHED ONE LINE DIAGRAM - NO SCALE 3 0 FEEDER SCHEDULES 3 WIRE FEEDERS 4 WIRE FEEDERS FEEDER DESIGNATION CONDUIT SIZE(S) CONDUCTORS & GROUNDING CONDUCTOR(S) SIZES FEEDER DESIGNATION CONDUIT SIZE(S) CONDUCTORS & GROUNDING CONDUCTOR(S) SIZES 20 - 3G 1/2" (3) #12 & #12 GND 20 - 4G 1/2" (4) #12 & #12 GND 25 - 3G 3/4" (3) #10 & #10 GND 25 - 4G 3/4" (4) #10 & #10 GND 30 - 3G 3/4" (3) #10 & #10 GND 30- 4G 3/4" (4) #10 & #10 GND 35 - 3G 3/4" (3) #8 & #10 GND 35 - 4G 3/4" (4) #8 & #10 GND 40 - 3G 3/4" (3) #8 & #10 GND 40 - 4G 3/4" (4) #8 & #10 GND 45 - 3G 3/4" (3) #6 & #10 GND 45 - 4G 3/4" (4) #6 & #10 GND 50 - 3G 1" (3) #6 & #10 GND 50 - 4G 1" (4) #6 & #10 GND 60 - 3G 1" (3) #4 & #8 GND 60 - 4G 1-1/4" (4) #4 & #8 GND 70 - 3G 1" (3) #4 & #8 GND 70 - 4G 1-1/4" (4) #4 & #8 GND 80 - 3G 1" (3) #3 & #8 GND 80 - 4G 1-1/4" (4) #3 & #8 GND 90 - 3G 1-1/4" (3) #2 & #8 GND 90 - 4G 1-1/4" (4) #2 & #8 GND 100 - 3G 1-1/4" (3) #2 & #8 GND 100 - 4G 1-1/4" (4) #2 & #8 GND 110 - 3G 1-1/4" (3) #1 & ilk GND 110 - 4G 1-1/2" (4) #1 & #6 GND 125 - 3G 1-1/4" (3) #1 & #6 GND 125 - 4G 1-1/2" (4) #1 & #6 GND 200 - 3G 2" (3) #3/0 & #2 GND 200 - 4G 2" (4) #3/0 & #2 GND 225 - 3G 2" (3) #4/0 & #2 GND 225 - 4G 2-1/2" (4) #4/0 & #2 GND 400 - 3G 3" (3) 500 kcmil & #1/0 GND 400 - 4G 3-1/2" (4) 500 kcmil & #1/0 GND nw x.j vruuna �.vnauuwu ame may De neumea aasea vn vvercurreni #%na/vr tirouna rouii rroiecuon cquipmeni km.L' 250) NOTE: Conductor Sizes Listed Above Are For Copper. 1/2" ARMAFLEX CLOSED CELL INSULATION 1 i SLAB "4 RIGID STEEL ELBOW. CONDUIT PER SEAL AROUND — SPECIFICATIONS CONDUCTORS WITH COMPOUND GRADE CONDUIT PER - SPECIFICATIONS /ZZ, RIGID STEEL CONDUIT PER CONDUIT BODY ; / CONDUIT SPECIFICATIONS OR J-BOX. PVC SLEEVE IF SILICONE CAULK WALL IS NEW, (TYP. BOTH SIDES) CORE DRILL IF EPANDING WALL IS EXISTING POLYURETHANE FLOOR SLAB ON GRADE EXTERIOR BASEMENT FOAM WALL BELOW GRADE SEAL AROUND - CONDUIT CONDUCTORS WITH COMPOUND JUSTABLE CLAMP J-BOX OR DEEP BACK PIPE SEAL - CENTER LB W/GASKETED COVER NEOPRENE OVER HOLE IN ROOF CONDUIT PER BOOT FLASHING CONDUIT PER SPECIFICATIONS SPECIFICATIONS (BY ROOFER NTH STAINLESS STEEL MOUNTING HARDWARE �% SILICONE CAULK ROOFING FINISHED (TYP. BOTH SIDES) GRADE -_ - ED EXPANDING "= POLYURETHANE so FOAM RIGID CUT HOLE IN ROOF N INSULATION AS REQUIRED i NOTE: CONDUIT PER mly - COORDINATE ALL ROOF PENETRATIONS WITH ROOFING SPECIFICATIONS r CONTRACTOR. - FRIGID STEEL ROOF EXTERIOR SOW WALL ABOVE GRADE NOTE: - SEE SPECIFICATIONS FOR CONDUIT MATERIAL BEYOND COUPLINGS. - SEE SPECIFICATIONS FOR INTERIOR WALL AND FLOOR PENETRATION REQUIREMENTS. CONDUIT PENETRATION DETAILS - NO SCALE GENERAL ELECTRICAL NOTES • SEE ARCHITECTURAL REFLECTED CEILING AND ELEVATION PLANS FOR LOCATION OF ALL LIGHTING FIXTURES. LOCATE FIXTURES IN ACCORDANCE WITH CEILING AND ELEVATION PLANS. • ONELINE DIAGRAMS AND RISER DIAGRAMS ARE A DIAGRAMMATIC REPRESENTATION TO AID THE CONTRACTOR IN UNDERSTANDING THE FUNCTION AND OPERATION OF THE SYSTEMS. E.C. SHALL REVIEW THE ONELINES, RISERS, AND FLOOR PLANS FOR THE EXACT QUANTITIES AND LOCATION OF ALL EQUIPMENT. E.C. SHALL FURNISH AND INSTALL ALL EQUIPMENT SHOWN ON ANY OR ALL OF THESE DIAGRAMS AND DRAWINGS. DETAILED WIRING DIAGRAMS SHOWING ACTUAL WIRING FOR THE SYSTEMS FURNISHED SHALL BE A PART OF THE SHOP DRAWING SUBMITTAL • DEVICE LOCATIONS MAY BE DISTORTED FOR CLARITY. LOCATE DEVICES SYMMETRICALLY WITH THE ARCHITECTURAL ELEMENTS. • CONTRACTOR SHALL COORDINATE WITH THE OTHER TRADES TO VERIFY SPACES ARE CLEAR OF OBSTRUCTIONS. MAINTAIN MAXIMUM HEADROOM AND SPACE CONDITION AT ALL POINTS IN THE BUILDING. WHERE HEADROOM OR SPACE CONDITIONS APPEAR INADEQUATE, NOTIFY ARCHITECT/ENGINEER BEFORE PROCEEDING WITH THE INSTALLATION. • FURNISH OTHER TRADES ADVANCE INFORMATION ON LOCATIONS AND SIZES OF PIPING. DUCTWORK, EQUIPMENT, FRAMES, BOXES, SLEEVE AND OPENINGS NEEDED FOR WORK. FURNISH INFORMATION AND SHOP DRAWINGS TO PERMIT TRADES AFFECTED TO INSTALL THEIR WORK PROPERLY AND WITHOUT DELAY. • SEE HVAC AND PLUMBING PLANS FOR LOCATIONS OF HEATING, VENTILATING, AIR CONDITIONING AND PLUMBING EQUIPMENT. DO NOT REFERENCE ELECTRICAL DRAWINGS FOR EXACT LOCATION. • SCHEDULE REQUIRED POWER, TELEPHONE, OR DATA OUTAGES IN OCCUPIED AREAS OF THE BUILDING WITH THE OWNER. CONTRACTOR SHALL WORK UNTIL SERVICE IS RESTORED. OUTAGE WORK SHALL BE DONE AFTER OR BEFORE NORMAL WORKING HOURS, ON WEEKENDS OR HOLIDAYS. BRANCH CIRCUIT FEEDER SCHEDULE AMP/POLE CONDUCT. GND. CONDUCT. CON. 15A/1P OR 15A/2P (2) #12 #12 1/2" 20A/1P OR 2OA/2P (2) #12 #12 1/2" 15A/3P OR 2OA/3P (3) #12 #12 1/2" 25A/1P OR 25A/2P (2) #10 #10 3/4" 30A/1P OR 30A/2P (2) #10 #10 3/4" 25A/3P OR 3OA/3P (3) #10 #10 3/4" 35A/1P OR 35A/2P (2) # 8 #10 3/4" 4OA/1P OR 4OA/2P (2) # 8 #10 3/4" 35A/3P OR 4OA/3P (3) #8 #10 3/4" 45A 1P OR 45A 2P 2 1" 45A/3P OR 5OA/3P (3) #6 #10 1" 5OA/1P OR 5OA/2P (2) #6 #10 1" 60A/1P OR 60A/2P (2) #4 #8 1" 60A/3P (3) #4 #8 1 1/4" 70A/3P OR 8OA/3P (3) #4 #8 1 1/4" 90A/3P 1 (3) #3 #8 1 1 /4" 10OA/3P OR 11OA/3P 1 (3) #2 #6 1 1/2" 125A/3P 1 (3) #1 1 #6 1 1/2" - PROVIDE BRANCH CIRCUIT FEEDERS AS NOTED ABOVE, UNLESS NOTED OTHERWISE. LEGEND NOTE: ALL SYMBOLS SHOWN MAY NOT APPEAR ON DRAWINGS. ALL MOUNTING HEIGHTS ARE TYPICAL UNLESS OTHERWISE NOTED. SYM. IDENTIFICATION SYM. IDENTIFICATION SYM. IDENTIFICATION SYM. IDENTIFICATION COMMUNICATION TELEPHONE OUTLET WITH 1" C. STUBBED ► INTO AN ACCESSIBLE SPACE. MOUNTED 18" AFF TO CENTER. W = WALL MOUNTED 0 52" AFF TO CENTER DATA OUTLET WITH 1" C. STUBBED D INTO AN ACCESSIBLE SPACE. MOUNTED X 18" AFF TO CENTER. X = NUMBER OF DATA DROPS PER BOX. COMBINATION TELEPHONE/DATA WITH 1" C. STUBBED INTO AN ACCESSIBLE SPACE. MOUNTED 0 18" AFF TO CENTER. © CEILING MOUNTED SPEAKER © TELEVISION OUTLET MOUNTED 0 18" AFF TO CENTER EQUIPMENT -111g- SURFACE MOUNTED PANELBOARD RECESSED PANELBOARD �- O EQUIPMENT CONNECTION ■.. ■ SURFACE MOUNTED RACEWAY FIRE RATED WALLS �. = FIRE -BARRIER - 1 HOUR - _ FIRE -BARRIER - 2 HOUR + e a FIRE -BARRIER - 3 HOUR �'= FIRE -PARTITION - 1 HOUR FIRE -PARTITION - 2 HOUR FIRE -WALL - 2 HOUR FIRE -WALL - 3 HOUR .:_��=mm FIRE -WALL- 4HOUR PANEL EXISTING wA2w AMPS: 200A Voltage: 208/120V M.L.O.: YES Phase: 3 Main Breaker: NO Wire: 4 Main Breaker Size: - A.I.C.: 10,000(1) Sub Feed Lugs: NO Mount: SURFACE Sub Feed Lug Size: — Bus Type: CU AL Ground Bus: YES DESCRIPTION BKR BKR DESCRIPTION 1 LIGHTS EXITS 20 1 20 1 MISC PHONE BOARD CP-1 CEF-4 2 3 LIGHTS SWITCH A 20 1 20 1 RECEP STAFF LOUNGE 4 5 LIGHTS SWITCH B 20 1 20 1 RECEP STAFF LOUNGE MW 6 7 LIGHTS SWITCH C 20 1 20 1 RECEP STAFF LOUNGE REF 8 9 LIGHTS SWITCH D 20 1 20 1 RECEP LAB 10 11 RECEP LAB 20 1 20 1 IRECEP LAB 12 13 RECEP LAB / CEF-3 201 20 1 RECEP LAB 14 15 IRECEP LAB REF 20 1 20 1 RECEP LAB 16 17 RECEP LAB 20 1 20 1 RECEP PHONE SYSTEM 18 19 RECEP LAB 20 1 20 1 RECEP HAND DRYER 20 21 RECEP TREATMENT #8 20 1 20 1 RECEP CORRIDOR CEF-2 22 23 RECEP TREATMENT #7 201 20 1 MISC TREATMENT 5 X-RAY 24 25 RECEP TREATMENT #6 20 1 25 2 MOTOR RTAC-3 26 27 RECEP TREATMENT #5 20 1 2 MOTOR 28 29 RECEP ROOFTOP 20 1 30 2 MOTOR VACUUM SYSTEM 30 31 MOTOR EX. RTAC-1 2 40 3 2 MOTOR 32 33 MOTOR 3 20 2 RECEP AIR COMPRESSOR 34 35 MOTOR 3 2 RECEP 36 37 MOTOR EX. RTAC-2 2 40 3 100 3 MISC NEW PANEL B2 38 39 MOTOR 3 3 MISC 40 41 MOTOR 3 3 IMISC 142 - (1) L.C. IU VLKll-Y AVAILAtiLL tAULI UUKKLN I. — (2) DENOTES UNIT IS EXISTING. E.C. TO VERIFY CIRCUIT AND BREAKER SIZES. PANEL NEW 82 AMPS: 100A Voltage: 208/120V M.L.O.: YES Phase: 3 Main Breaker: NO Wire: 4 Main Breaker Size: — A.I.C.: 10,000(1) Sub Feed Lugs: NO Mount: SURFACE Sub Feed Lug Size: — Bus Type: CU AL Ground Bus: YES DESCRIPTION BKR BKR DESCRIPTION 1 RECEP TREATMENT #1 20 1 20 1 RECEP STERILIZATION 2 3 RECEP TREATMENT #2 20 1 20 1 RECEP TREATMENT#4 4 5 IRECEP BUSINESS CENTER 20 1 20 1 RECEP CONSULTATION 6 7 RECEP BUSINESS CENTER 20 1 20 1 MISC PANORAMIC X—RAY 8 9 RECEP EWC-1 20 1 20 1 RECEP INTRA—ORAL CPU 10 11 RECEP TREATMENT 20 1 20 1 MISC HAND DRYER 12 13 MISC SIGNAGE & TIMECLOCK 20 1 20 1 RECEP STERILIZATION 14 15 RECEP RECEPTION CEF-1 20 1 1 20 1 SPARE 16 17 LIGHTS EXTERIOR 20 1 20 1 SPARE 18 19 20 21 RECEP PANORAMIC X—RAY 20 2 20 2 1 RECEP STERILIZER 22 23 RECEP 2 2 IRECEP 24 - (1) L.G. TU VEKIF Y AVAILALILL t AUL I GUKKLN I . DEVICESWRING SINGLE POLE SWITCH S MOUNTED 0 46" AFF TO CENTER, 3=3 WAY, 4=4 WAY, P=PILOT. D=DIMMER DUAL LEVEL SWITCHING MOUNTED 0 46" AFF TO CENTER SEE DETAIL ® LOW VOLTAGE SWITCH MOUNT 0 46" AFF TO CENTER DUPLEX RECEPTACLE MOUNTED 0 18" AFF TO CENTER DOUBLE DUPLEX RECEPTACLE MOUNTED O 18" AFF TO CENTER DUPLEX RECEPTACLE MOUNTED VERTICALLY 6" ABOVE BACKSPLASH TO CENTER, IF NO BACKSPLASH MOUNT 6" ABOVE COUNTER. ,III DUPLEX RECEPTACLE `FY MOUNTED IN CEILING/SOFFIT. DUPLEX RECEPTACLE MOUNTED IN CABINET BEHIND MICROWAVE. FIELD VERIFY HEIGHT. POWER RECEPTACLE MTD 0 18" AFF TO CENTER SWITCH BOTTOM HALF OF RECEPTACLE. TOP HALF UNSWITCHED. O SPECIAL OUTLET OJ JUNCTION BOX 0 IN -FLOOR RECEPTACLE COMBINATION FLOOR OUTLET/BLANK ® JUNCTION BOX - WIREMOLD - RESOURCE RFB / SERIES OR EQUIVALENT. PROVIDE 1" CONDUIT STUB TO NEAREST ACCESSIBLE SPACE. BLANK BOX 0 4" EXTRA DEEP BOX, SINGLE GANG RING, BLANKPLATE, 1 "C. STUBBED INTO ACCESSIBLE SPACE. MOUNTED 0 18" AFF TO CENTER ABOVE COUNTER BLANK BOX 4" EXTRA DEEP BOX, SINGLE GANG RING, BLANKPLATE, 1"C. STUBBED INTO ACCESSIBLE SPACE. MID 6" ABOVE BACKSPLASH TO CENTER DOUBLE DUPLEX RECEPTACLE MOUNTED VERTICALLY 6" ABOVE BACKSPLASH TO CENTER. IF NO BACKSPLASH MOUNT 6" ABOVE COUNTER. MISC �3 CONDUIT STUB THROUGH WALL BUSHED EACH END � CONDUIT WITH BUSHING ON END. REFERS TO NOTE WITH NUMBER "X" �.� ELECTRICAL HOMERUN, CIRCUIT AS SHOWN /•.� SHARED ELECTRICAL HOMERUN, CIRCUIT AS SHOWN ---� CONNECTED TO CIRCUIT BUT NOT SWITCHED WITH CIRCUIT. ITEMS AND/OR DEVICES SWITCHED, CONTROLLED OR CONNECTED TOGETHER • PUSHBUTTON PROVIDE JUNCTION BOX AND CONDUIT. MOUNT AT SWITCH HEIGHT. LIGHTING O RECESSED, SURFACE, OR PENDANT MOUNTED LIGHT FIXTURE a WALL MOUNTED LIGHT FIXTURE MOUNTED 0 7'-0" AFF OR 8" ABOVE MIRROR FLUORESCENT FIXTURE EMERGENCY LIGHT. 11'-0" AFF TO TOP OR 8" BELOW CEILING WHICHEVER IS LOWER RECESSED EMERGENCY LIGHT EXIT LIGHT ® OCCUPANCY SENSOR WALL MOUNTED OCCUPANCY SENSOR WITH SWITCH 00 DUAL LEVEL/CIRCUIT OCCUPANCY SENSOR WITH SWITCH OpC PHOTO CONTROL EXTERIOR WALL MOUNTED FIXTURE OR INTERIOR WALL WASH FIXTURE FLUORESCENT STRIP �--� ®LIGHT 2-LAMP FIXTURE CONNECTED TO NIGHT CIRCUIT. 3 AND 4 LAMP FIXTURE CENTER LAMP(S) CONNECTED TO NIGHT LIGHT CIRCUIT 4 FOOT WALL MOUNTED LIGHT FIXTURE MOUNTED 0 7'-6" AFF OR 8" ABOVE MIRROR •� SINGLE HEAD POLE TWIN HEAD POLE MOUNTED FIXTURE E=]�&fl FIRE ALARM / LIFE SAFETY STROBE MOUNTED 0 84" AFF TO TOP OR 6" BELOW CEILING WHICHEVER IS LOWER ® SPEAKER CEILING MOUNTED W - WALL MOUNTED HORN/STROBE MOUNTED 0 84" AFF TO TOP OR 6" BELOW CLG WHICHEVER IS LOWER. STROBE SPEAKER MOUNTED 0 84" AFF TO TOP OR 6" BELOW CLG WHICHEVER IS LOWER. HORN (SOUNDER) MOUNTED 0 84" AFF TO TOP OR 6" BELOW CLG WHICHEVER IS LOWER. a PULL STATION MOUNTED 0 46" AFF TO CENTER ® HEAT DETECTOR ® CARBON MONOXIDE DETECTOR SO SMOKE DETECTOR & DUCT SMOKE DETECTOR SOE ELEVATOR SMOKE DETECTOR SMOKE DETECTOR WITH SOUNDER BASE L MAGNETIC DOOR HOLDER ® SPRINKLER FLOW SWITCH ® SPRINKLER TAMPER SWITCH Q SPRINKLER BELL ® FIRE ALARM CONTROL PANEL ® FIRE ALARM ANNUCIATOR PANEL RRM AREA OF REFUGE STATION ® AREA OF REFUGE LIGHTING WM AREA OF REFUGE MASTER PANEL ABBREVIATIONS AC ABOVE COUNTER AFF ABOVE FINISHED FLOOR AFG ABOVE FINISHED GRADE BRD BOARD C CONDUIT C/T CURRENT TRANSFORMER DISC DISCONNECT DSHWSH DISHWASHER EC ELECTRICAL CONTRACTOR ELEV ELEVATION EM EMERGENCY ETR EXISTING TO REMAIN EWC ELECTRIC WATER COOLER FBO FURNISHED BY OTHERS FLA FULL LOAD AMPS FPC FIRE PROTECTION CONTRACTOR G.C. GENERAL CONTRACTOR GDSP GARBAGE DISPOSAL GFI GROUND FAULT CIRCUIT INTERRUPTED GND GROUND HC HVAC CONTRACTOR HP HORSE POWER IG ISOLATED GROUND LCP LIGHTING CONTROL PANEL MCA MINIMUM CIRCUIT AMPS MID MOUNTED NL NIGHT LIGHT NTS NOT TO SCALE OC ON CENTER PC PLUMBING CONTRACTOR PH PHASE PNL PANELBOARD REF REFRIGERATOR SS STAINLESS STEEL UC UNDER COUNTER WP WEATHERPROOF WP/GFI WEATHER PROOF AND GROUND FAULT CIRCUIT INTERRUPTED WT WATER TIGHT XFMR TRANSFORMER SECURITY ® DOOR CONTACT 1ES1 ELECTRIC STRIKE CR CARD READER MOTOR CONTROL DISCONNECT FURNISHED BY E.C. F=FUSIBLE ® NON -COMBINATION STARTER COMBINATION STARTER ©S MANUAL STARTER a MOTOR CONNECTION mill EXCEL ENGINEERING. 100 CAMELOT DRIVE FOND DU LAC, WI 54935 PHONE: (920) 926-98W FAX: (920) 926-9801 Always a Better Plan U7 O Q ~ Z Y Y � w 0 W CL < Y LLI Z Q W Lj z 0 L,..i J V) z w Q W W o o z W }- Z Z (n W O CL < � ° Cn Nw N Q W H 0 W W � Z W Z w U W� Q W =) J _J L.L. E- Z 0 J r N J U w J W >Y IZ (/.) IZ W O � CL W CL Q N � N SHEET ISSUE: NOVEMBER 23, 2009 SEE TITLE SHEET TO CONFIRM THAT THIS SHEET HAS BEEN RELEASED FOR CONSTRUCTION REVISIONS: DATE: Z NOV. 23, 2009 z JOB NUMBER: 914790 w W Z W SHFFT J W U x W mpen[DaRta W E0. 1 rn O O N ONELINE DIAGRAM •) BREAKER • DCL CURRENT LIMITING BREAKER 0 FUSED SWITCH • GFP ELECTRONIC BREAKER WITH C/T'S AND GROUND FAULT PROTECTION ELECTRICAL SPECIFICATIONS I. GENERAL REQUIREMENTS A. IN AS MUCH AS THE SPECIFICATIONS ARE BRIEF, THE CONTRACTOR SHALL PROVIDE WORKMANSHIP THAT IS OF THE BEST QUALITY WITH THE BEST POSSIBLE APPEARANCE AND UTILITY. FAULTY WORK SHALL BE REPAIRED OR REPLACED AT NO COST TO THE OWNER. INDUSTRY STANDARDS SHALL BE USED AS THE GUIDE FOR QUALITY OF MATERIALS AND WORKMANSHIP. B. ENTIRE INSTALLATION SHALL BE PREPARED IN A FIRST-CLASS WORKMANLIKE MANNER. THE COMPLETED SYSTEMS SHALL BE FULLY OPERATIONAL. ACCEPTANCE BY OWNER SHALL BE A CONDITION OF THE CONTRACT. ALL WORK SHALL BE COORDINATED WITH OTHER TRADES IN ORDER TO AVOID INTERFERENCES OR DISPUTES AMONG RESPECTIVE TRADES. C. ELECTRICAL CONTRACTOR SHALL THOROUGHLY FAMILIARIZE HIMSELF WITH THE PLANS (ARCHITECTURAL, MEP, EQUIPMENT SUPPLIER DRAWINGS, LANDLORD DRAWINGS, ETC.) AND SHALL VERIFY EXISTING CONDITIONS AT THE SITE. D. THE ELECTRICAL CONTRACTOR'S CONTRACT SHALL INCLUDE BUT NOT BE LIMITED TO THE FOLLOWING: WIRING, CONDUIT, PANELBOARDS, TRANSFORMERS, SWITCHES, RECEPTACLES, TIME CLOCK, JUNCTION BOXES AND LABOR. E. ELECTRICAL CONTRACTOR IS RESPONSIBLE TO PROVIDE ANY AND ALL ITEMS NECESSARY TO COMPLETE THIS PROJECT AS DRAWN. F. ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL ALL ELECTRICAL EQUIPMENT AND WIRING IN ACCEPTANCE WITH THE LANDLORD'S DESIGN CRITERIA. II. BASIC ELECTRICAL REQUIREMENTS A. ELECTRICAL CONTRACTOR SHALL VERIFY REQUIREMENTS FOR TEMPORARY LIGHTING AND POWER WITH GENERAL CONTRACTOR AND INCLUDE IN HIS SCOPE OF WORK WHEN DIRECTED BY G.C. INSTALL IN ACCORDANCE WITH ALL CODE AND OSHA REQUIREMENTS FOR CONSTRUCTION PROJECTS. B. SHOP DRAWINGS: 1. INCLUDE OUTLINE AND GENERAL ARRANGEMENT DRAWINGS, DATA SHEETS AND WIRING DIAGRAMS. 2. MARK GENERAL CATALOG SHEETS AND DRAWINGS TO INDICATE SPECIFIC ITEMS SUBMITTED, AND THE TOP OF THE PAGE AS TO WHAT ITEM THE SHEET COVERS. INCLUDE PROPER IDENTIFICATION OF EQUIPMENT BY MANUFACTURER'S NAME AND MODEL NUMBER, AND NOTATION OF ALL OPTIONS. 3. SYSTEM WIRING RISER DIAGRAMS SHALL INDICATE ALL COMPONENTS SHOWN ON THE FLOOR PLANS, TYPE AND TERMINATION POINT OF CABLE TO EACH COMPONENT. C. DETAILS AND SCHEDULES ARE SHOWN TO AID THE CONTRACTOR AND ARE NOT MEANT TO BE INCLUSIVE OF ALL DEVICES. PROVIDE REQUIRED EQUIPMENT AND ACCESSORIES FOR A COMPLETE INSTALLATION. D. COMPLY WITH THE REQUIREMENTS OF NFPA; NATIONAL, STATE AND LOCAL ELECTRICAL CODES AND LOCAL UTILITY REGULATIONS. E. MATERIAL SHALL BEAR U.L AND/OR OTHER APPROVED AGENCY LISTING. F. COORDINATE INSTALLATION OF ELECTRICAL WORK WITH THE OTHER CONTRACTORS TO AVOID CONFLICTS WITH OTHER WORK. G. INSTALL MOTOR STARTERS/VFDS FURNISHED BY HEATING AND PLUMBING CONTRACTORS, AND WIRE FROM THE POWER SOURCE TO THE STARTER/VFD AND FROM THE STARTER/VFD TO THE MOTOR. SEE HVAC AND PLUMBING DRAWINGS FOR ADDITIONAL INFORMATION. H. VERIFY ELECTRICAL SIZE AND CONNECTION REQUIREMENTS FOR EQUIPMENT FURNISHED BY OTHERS. I. PROVIDE ALL CUTTING AND PATCHING NECESSARY FOR ELECTRICAL WORK INSTALLATION UNLESS THIS WORK IS IDENTIFIED TO BE THE WORK OF OTHER CONTRACTORS. PATCHING SHALL MATCH ADJACENT SURFACES. CORE DRILL OR SAW -CUT OPENINGS THROUGH EXISTING CONCRETE. J. PROJECT COMPLETION 1. CLEAN FIXTURES AND EQUIPMENT AND LEAVE IN PROPER WORKING CONDITION AT THE TIME OF FINAL CLEAN-UP. 2. MARK RECORD DRAWINGS ON A FINAL SET OF DRAWINGS WHICH INCLUDES ALL REVISIONS. K. LOCATION 1. THE ARCHITECT SHALL RESERVE THE RIGHT TO MAKE OUTLET POSITION CHANGES UP TO 10' BEFORE INSTALLATION. 2. DO NOT LOCATE OUTLETS OR EQUIPMENT WHERE THE USEFULNESS AND/OR OPERATION WILL BE AFFECTED BY THE WORK OF OTHER TRADES, DOOR SWING, COUNTER, EQUIPMENT, ETC. L. ACCESS 1. INSTALL EQUIPMENT, JUNCTION BOXES, PULL BOXES AND ACCESSORIES TO PERMIT ACCESS WITHOUT RELOCATING INSTALLED OR YET TO BE INSTALLED EQUIPMENT. 2. ACCESS PANELS a) FURNISH ACCESS PANELS OF ADEQUATE SIZE TO PERMIT SERVICE OF CONCEALED DEVICES. PANELS SHALL BE SUITABLE FOR INSTALLATION IN THE MATERIAL FORMING THE FINISHED SURFACE, WITH FLUSH METAL FRAME, FLUSH HINGED STEEL DOOR, FLUSH SCREWDRIVER OPERATED LATCH. b) PANELS UL LISTED TO CONFORM TO THE FIRE RATING OF THE SURFACE INSTALLED IN. c)TURN ACCESS PANEL OVER TO CONTRACTOR SKILLED IN THE CONSTRUCTION OF THE SURFACES INVOLVED FOR INSTALLATION. d) ARCHITECT TO APPROVE ACCESS PANEL LOCA11ON PRIOR TO INSTALLATION OF EQUIPMENT REQUIRING ACCESS. e) COORDINATE WITH THE OTHER CONTRACTORS AND WHEREVER PRACTICAL, GROUP DEVICES IN SUCH A MANNER SO AS TO MINIMIZE PANELS. M. ELECTRICAL CONTRACTOR TO PROVIDE PULL WIRE IN EMPTY CONDUIT FOR TELEPHONE OR AS REQUIRED BY LOCAL PHONE COMPANY. N. ALL NEW MATERIALS, WORKMANSHIP AND EQUIPMENT SHALL BE GUARANTEED FOR ONE YEAR AFTER SYSTEM ACCEPTANCE. 0. ALL WIRING SHALL BE IN CONDUIT AS REQUIRED BY LOCAL CODE AND SHALL BE CONCEALED WHERE POSSIBLE. WHERE EXPOSED, RUN IN STRAIGHT LINES PARALLEL AND/ OR PERPENDICULAR TO BUILDING LINES. P. ELECTRICAL CONTRACTOR SHALL INCLUDE ALL MISCELLANEOUS ITEMS REQUIRED TO COMPETE THE WORK. Q. ELECTRICAL CONTRACTOR SHALL NOT SCALE DRAWINGS FOR DIMENSIONS BUT SHALL CONTACT THE OWNER'S REPRESENTATIVE REGARDING ANY DIMENSIONAL DATA REQUIRED AND SHALL VERIFY EXACT LOCATION AND MOUNTING HEIGHTS OF ALL FIXTURES, NOT SPECIFIED ON DRAWINGS OR DETAILS WITH OWNER'S REPRESENTATIVE PRIOR TO INSTALLATION. R. ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL ALL FIXTURES, LAMPS, AND REPLACEMENT WORK THAT IS NOT INDICATED ON THE DRAWINGS UNLESS OTHERWISE NOTED. ALL SUCH INSTALLATION AND HOOK-UPS ARE BY ELECTRICAL CONTRACTOR. S. ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE TO INSTALL OR REMOVE AND REPLACE AS NECESSARY ALL DAMAGED LIGHT FIXTURE LENSES, LOUVERS, BAFFLES, HOUSINGS, ETC. RECEIVED ON JOB IN DAMAGED OR DEFECTIVE CONDITION WITH REPLACEMENT UNITS. T. ELECTRICAL CONTRACTOR TO PROVIDE CIRCUIT "LOCK -ON" CUPS AND INSTALL SAME ON THE FOLLOWING CIRCUITS: WATER HEATER, NIGHT / EMERGENCY LIGHTING, PHONE, AND COMPUTERS. U. ELECTRICAL CONTRACTOR SHALL BALANCE THE LOADS ACROSS ALL PHASES AND SHALL PROVIDE A CIRCUIT DIRECTORY WITH TYPED CIRCUIT DESIGNATION CARD UNDER PLASTIC COVER ON THE INSIDE OF EACH PANEL DOOR. ELECTRICAL CONTRACTOR SHALL ALSO FURNISH AND INSTALL NAMEPLATES ON ALL DISCONNECT SWITCHES AND PANELS. ALL NEW ELECTRICAL MATERIALS, PRODUCTS AND EQUIPMENT (INCLUDING ALL COMPONENTS THEREOF) SHALL BEAR THE UNDERWRITER'S LABORATORIES LABEL AND MEET THE APPROPRIATE ASTM, NEC AND NEMA STANDARDS. V. THE ELECTRICAL CONTRACTOR IS RESPONSIBLE TO PROVIDE A TEMPORARY LIGHTING AND POWER SYSTEM FOR THE WORK OF ALL TRADES DURING CONSTRUCTION, AND SHALL REMOVE THE SAME PRIOR TO THE COMPLETION OF THE PROJECT. W. TENANTS ELECTRICAL CONTRACTOR SHALL BE REQUIRED TO PROVIDE TEMPORARY POWER WITH GROUND FAULT PROTECTION FOR ALL POWER EQUIPMENT USED IN THE PREMISES, AND SHALL REMOVE THE SAME PRIOR TO THE COMPLETION OF THE PROJECT. III. UTILITIES A. UTILITY COST BY OWNER. B. ELECTRIC UTILITIES 1. EXISTING ELECTRICAL SERVICE C. TELEPHONE UTILITIES 1. EXISTING TELEPHONE SERVICE D. CABLE TELEVISION UTILITY 1. EXISTING CABLE TELEVISION SERVICE IV. FINISH AND PAINTING A. E.C. SHALL PROVIDE A FACTORY OR FIELD APPLIED PRIME AND FINISH COAT OF COLOR SELECTED BY THE OWNER'S REPRESENTATIVE TO ALL ROOF MOUNTED EQUIPMENT AND OTHER EXTERIOR MATERIALS, INCLUDING SUPPORT HARDWARE. B. COORDINATE WORK WITH THE PAINTERS SO THAT ALL EQUIPMENT IS INSTALLED PRIOR TO PAINTING. E.C. SHALL PAINT ITEMS IF NOT IN PLACE PRIOR TO NORMAL ROUTINE PAINTING. C. IF FINISH BECOMES RUSTED, CORRODED, SCRATCHED, OR FLAKED DURING STORAGE OR INSTALLATION, REFINISH THE EQUIPMENT TO THE SATISFACTION OF THE OWNER. D. WHERE THE ELECTRICAL CONTRACTOR IS REQUIRED TO PAINT, THE PAINTING SHALL BE DONE IN ACCORDANCE WITH THE PAINTING PORTION OF THE ARCHITECTURAL SPECIFICATION. E. E.C. SHALL PROVIDE FINISH/PAINT WHERE SPECIFIED ELSEWHER. V. SUPPORTS A. CONDUIT HANGERS, ATTACHMENTS, AND SUPPORTS 1. PROVIDE PROPER FITTINGS AND SUPPORT SUITABLE FOR AMBIENT/ENVIRONMENTAL CONDITIONS AND SERVICE DUTY. 2. ATTACH TO STRUCTURAL COMPONENTS TO NOT JEOPARDIZE STRUCTURAL INTEGRITY. 3. PROVIDE ANGLES, CHANNELS, AND BEAMS AS REQUIRED. B. BACKBOARDS 1. 3/4" PLYWOOD PAINTED ON BOTH SIDES AND EDGES WITH TWO COATS OF WHITE ENAMEL PAINT TO MOUNT EQUIPMENT WHERE SHOWN. 2. SUPPORT WITH PAINTED OR GALVANIZED STEEL CHANNEL. C. CONCRETE PADS AND POLE BASES 1. PROVIDE FINAL INTERIOR EQUIPMENT CONCRETE PAD SIZE REQUIREMENTS TO CONCRETE CONTRACTOR. PADS SHALL EXTEND MINIMUM 2" BEYOND EQUIPMENT FOOTPRINT. 2. PROVIDE CONCRETE FOR EXTERIOR LIGHT POLE BASES AND EXTERIOR TRANSFORMER PADS PER DETAILS AND UTILITY REQUIREMENTS. FOR PADS WHICH UTILITY DOES NOT HAVE REINFORCING REQUIREMENTS, REINFORCING SHALL BE 6X6-W2.9XW2.9. D. ELECTRICAL CONTRACTOR IS RESPONSIBLE TO PROVIDE ANY AND ALL BLOCKING, CHAINS, HANGERS, ETC. AS NECESSARY TO SUPPORT LIGHTING SYSTEMS. VI. PENETRATIONS A. SLEEVES 1. FURNISH RIGID CONDUIT SLEEVES FOR CONDUITS AND CABLES PASSING THROUGH MASONRY, CONCRETE, OR OTHER SIMILAR CONSTRUCTION. 2. EXTEND SLEEVES COMPLETELY THROUGH THE CONSTRUCTION. EXTEND 1" ABOVE FLOORS. EXTEND 3" ABOVE THE FLOOR IN MECHANICAL ROOMS AND OTHER AREAS WHERE WATER MAY ACCUMULATE. 3. SLEEVES FOR CONDUITS 4" AND SMALLER: TWO SIZES LARGER THAN CONDUIT. 4. SLEEVES FOR CONDUITS LARGER THAN 4": ONE SIZE LARGER THAN CONDUIT. 5. FURNISH SLEEVE TO MASON FOR NEW MASONRY WALLS. 6. FURNISH, INSTALL, AND GROUT SLEEVE IN EXISTING MASONRY AND NEW CONCRETE WALLS. 7. SLEEVE NOT REQUIRED FOR DRYWALL WALLS OR CORE DRILLED HOLE IN CONCRETE WALL B. NON -FIRE RATED INTERIOR WALL AND FLOOR PENETRATIONS: FILL VOID BETWEEN CONDUIT AND SLEEVE, CONCRETE, OR DRYWALL WITH MINERAL WOOL CAULK BETWEEN CONDUIT AND SLEEVE OR WALL WITH NON -HARDENING CAULK. C. FIRE RATED INTERIOR WALL AND FLOOR PENETRATIONS: SEAL OPENING AROUND PIPE WITH A UL APPROVED FIRE -STOP SYSTEM HAVING AN F-RATING NOT LESS THAN THE HOURLY RATING OF THE ASSEMBLY BEING PENETRATED. D. SMOKE WALL PENETRATIONS: CONDUITS OR CABLES PENETRATING PENETRATION SHALL NOT DESTROY THE BARRIER'S INTEGRITY. E. ONLY U.L APPROVED CUT-OUTS WILL BE PREMITTED IN DEMISING AND OTHER FIRE RATED PARTITIONS FOR ELECTRICAL CIRCUITS / SWITCHES AND FOR ALL UTILITY PENETRATIONS. VII. IDENTIFICATION A. ENGRAVED LABELS: ENGRAVED 3-LAYER PHENOLIC LABEL WITH BLACK LETTERS ON WHITE MATERIAL, UNLESS OTHER COLORS ARE CALLED OUT ON THE DRAWINGS OR DETAILS. LABELS MINIMUM 3/4" HIGH AND 3" LONG. LABELS MAY BE ATTACHED WITH DOUBLE BACKED ADHESIVE TAPE UNLESS INDICATED OTHERWISE. LABELS REQUIRED AT: 1. PANELBOARDS: a) MOUNT IDENTIFICATION LABEL AT THE TOP OF THE FRONT COVER. MOUNT ON THE INSIDE OF DOOR FOR RECESSED PANELBOARDS. b) "FED FROM" LABEL. 2. DISCONNECT: LABEL EQUIPMENT THAT IT SERVES. B. PROVIDE TYPEWRITTEN DIRECTORY ACCURATELY INDICATING ROOMS AND/OR EQUIPMENT BEING SERVED AT THE FOLLOWING LOCATIONS: 1. PANELBOARDS C. EQUIPMENT IDENTIFICATION: IDENTIFY ALL EQUIPMENT AND APPARATUS WITH ENGRAVED BAKELITE NAMEPLATE OR IMPRESSED, PLASTIC STRIP. VIII. CONDUIT A. CONDUIT: ALL CONDUIT SHALL BE CONCEALED IN FINISHED AREAS. ALL CONDUIT UNDERGROUND OR IN CONCRETE SLAB SHALL BE RIGID CONDUIT. ALL OTHER CONDUIT MAY BE ELECTRICAL METALLICE TUBING (EMT). ALL CONDUITS SHALL BE RUN PARALLEL WITH AND AT RIGHT ANGLES TO THE BUILDING CONSTRUCTION AND SHALL BE LEVEL B. RMC 1. ALLOWED FOR ALL SIZES INSIDE ABOVE GRADE. 2. REQUIRED WHERE CALLED OUT ON PLANS. 3. REQUIRED FOR ALL SIZES OF OUTDOOR ABOVE GRADE CONDUIT. 4. GALVANIZED RIGID STEEL WITH GALVANIZED RIGID STEEL FITTINGS, THREADED WATERTIGHT. C. EMT 1. ALLOWED FOR INSIDE ABOVE GRADE CONDUIT 2" AND SMALLER. MINIMUM SIZE 1/2". 2. STEEL SET SCREW OR COMPRESSION TYPE FITTINGS WITH INSULATED THROAT. 3. CAST METAL SET SCREW FITTINGS NOT ALLOWED. D. FLEXIBLE 1. MINIMUM SIZE 1/2". 2. MAXIMUM LENGTH 36" FOR CONNECTION TO HVAC EQUIPMENT 3. MAXIMUM LENGTH 72" FOR CONNECTION TO FIXTURES IN TILE CEILINGS. 4. STEEL FITTINGS WITH INSULATED THROAT, UL LISTED. E. INSTALLATION 1. DRAWINGS AND DIAGRAMS SHOW SIZE AND APPROXIMATE LOCATION OF CONDUIT. THE DRAWINGS ARE DIAGRAMMATIC AND SHALL NOT BE SCALED TO DETERMINE EXACT LOCATION. PROVIDE ADDITIONAL OFFSETS AS REQUIRED FOR FIELD CONDITIONS. ROUTE CONDUIT IN ORDERLY MANNER, PARALLEL TO BUILDING STRUCTURE. CONCEAL CONDUIT IN FINISHED AREAS. 2. INSTALL UL APPROVED EXPANSION FITTINGS COMPLETE WITH GROUNDING JUMPERS WHERE CONDUITS CROSS BUILDINGS EXPANSION JOINTS AND IN LONG CONDUIT RUNS WHERE DIFFERENTIAL EXPANSION OR CONTRACTION WOULD CAUSE BENDING OR SEPARATION. 3. INSTALL CONDUIT WITH ADEQUATE DRAINAGE. 4. WHEN REQUIRED BY STATE AND LOCAL CODES AND ORDINANCES, PROVIDE SEPARATE CONDUIT/RACEWAY FOR FIRE ALARM, EMERGENCY STAND-BY, REQUIRED STAND-BY, TELECOMMUNICATION SYSTEMS. 5. ROUTE CONDUIT ABOVE LAY -IN SUSPENDED CEILINGS SO AS NOT TO INTERFERE WITH TILE REMOVAL 6. INSTALL FLEXIBLE STEEL CONDUIT DROPS FROM INDEPENDENT JUNCTION BOX MOUNTED ABOVE CEILING TO RECESSED LIGHT FIXTURES. 7. SECURE CONDUITS WITH AT LEAST ONE CORROSION PROOF MALLEABLE ALLOY STRAP OR HANGER EVERY 8 FT. DO NOT USE PERFORATED STRAPPING. 8. PROVIDE UL LISTED FIRE -WALL PENETRATIONS WHEN CONDUIT PASS THROUGH A FIRE RATED WALL IX. VARE A. TYPE AND SIZE 1. NO. 10 & 12: SOLID OR STRANDED COPPER, 60OV, THHN/THWN. 2. NO. 8 TO 250 KCMIL: STRANDED COPPER, 60OV, THHN/THWN. 3. MINIMUM BRANCH CIRCUIT WIRE SIZE NO. 12. 4. CONTROL WIRING: STRANDED COPPER, MINIMUM NO. 12. 5. GREEN INSULATION, COPPER STRANDED EQUIPMENT GROUND. 6. I 4AC C BL'�'T11fILED'Tfif'PATTENT"CARE-=AREAS SHAD -COMPLY° -WITH NEC B. NEUTRALS AND GROUNDS SHALL BE COLOR CODED PER NEC. C. WIRE COLORS 1. 120/208-VOLT AND 120/240-VOLT SYSTEM: PHASE -A (BLACK), PHASE-B (RED), PHASE-C (BLUE). D. TWO PERCENT VOLTAGE DROP AT PANELBOARDS AND THREE PERCENT FOR BRANCH CIRCUITS FOR FIVE PERCENT VOLTAGE DROP PER NEC. E. PROVIDE GROUNDING CONDUCTOR(S) WITH EVERY BRANCH CIRCUIT AND EVERY FEEDER. F. PROVIDE A SEPARATE GROUNDING CONDUCTOR AND SEPARATE NEUTRAL CONDUCTOR FOR EVERY RECEPTACLE BRANCH CIRCUIT. G. PROVIDE A SEPARATE NEUTRAL CONDUCTOR FOR EACH LIGHTING BRANCH CIRCUIT THAT SERVES HID AND ELECTRONIC FLUORESCENT BALLASTS OR PROVIDE A NEUTRAL CONDUCTOR ONE SIZE LARGER THEN THE LARGEST SOURCE CONDUCTOR WHEN THE NEUTRAL IS SHARED. X. BOXES A. FLUSH INTERIOR 4" SQUARE STEEL BOXES WITH RAISED COVERS AND SQUARE CUT CORNERS. PROVIDE BOXES RATED FOR THROUGH FEED. B. JUNCTION AND SPLICE BOXES SHALL HAVE GALVANIZED SCREW COVERS AND BE NOT LESS THAN CODE DIMENSIONS. THROUGH -WALL AND BACK-TO-BACK BOXES NOT ALLOWED. C. OUTLET AND JUNCTION BOXES USED AS SURFACE METAL RACEWAY SHALL BE MANUFACTURED BY THE SURFACE METAL RACEWAY MANUFACTURER TO BE COMPATIBLE WITH THE RACEWAY USED. D. VERIFY LOCATION PRIOR TO ROUGH -IN. MATCH THE HEIGHT OF EXISTING DEVICES FOR INSTALLATIONS IN ADDITIONS TO EXISTING FACILITIES. XI. DEVICES A. ALL DEVICES SHALL BE ALMOND IN COLOR. & RECEPTACLES 1. ALL CONVENIENCE DUPLEX RECEPTACLES SHALL BE LOCATED 18" A.F.F. UNLESS OTHERWISE NOTED ON PLANS. ALL OUTLETS SHALL BE FLUSH MOUNTED. 2. GROUND FAULT INTERRUPTER RECEPTACLES SHALL BE AS FOLLOWS: a) FOR INTERIOR APPLICATIONS: INSTALL GFI RECEPTACLE DESIGN TO TRIP AT 5MA IN 1 /30TH OF A SECOND RATED AT 115VAC / 20 A WITH FACE AND IVORYHIGH INMPACE NYLON COVER PLATE AS MANUVACTURED BY PASS AND SEYMOUR OR EQUAL b) FOR EXTERIOR APPLICATION: INSTALL GFI RECEPTACLES AS DESIGNED FOR TRIP AND RATING ABOVE. RECEPTACLES SHALL BE MOUNTED IN A BOX RATED NEMA 3R WITH COVER PLATE AS MANUFACTURED NYLON UNLESS NOTED OTHERWISE. MOUNTED AT 48" A.F.F. 3. NO CONVENIENCE DUPLEX RECEPTACLES SHALL BE LOCATED ON CERAMIC TILE OR A MIRRORED SURFACE UNLESS SPECIFICALLY REQUIRED BY CITY CODE. C. OUTLET BOXES: BOXES SHALL BE PRESSED STEEL KNOCKOUT TYPE, CAST IRON WITH DRILLED, TAPPED AND PLUGGED HOES, OR PVC. CAST IRON BOXES SHALL BE HOT DIPPED GALVANIZED OR SHERARDIZED. ALL BOXES SHALL BE OF PROPER CODE SIZE FOR THE NUMBER OF WIRES OR CONDUITS PASSING THROUGH OR TERMINATING THEREIN. D. LIGHT SWITCH BOXES: ENCLOSURE BOXES TO SERVE FOR VARIOUS LIGHT CONTROL SWITCHES (PER PLANS) AND MEET SAME CRITERIA AS FOR OUTLET BOXES. ALL BOXES SHALL (AS A MINIMUM STANDARD) BE RATED FOR THE VOLTAGE AND AMPERAGE OF THE CIRCUIT BEING SWITCHED AND / OR TO MEET LOCAL CODES AND ORDINATNCES. E. LIGHT SWITCHES 1. GENERAL USE SNAP SWITCHES AS INDICATED ON PLANS ARE AS MANUFACTURED BY LEVITON PASS AND SEYMOUR OR EQUAL AND SHALL BE RATED AT 20A/125 VAC. THE SWITCH FACE SHALL BE OF ALMOND HIGH-IM PACT NYLON WITH A BRUSHED STAINLESS COVERPLATE UNLESS NOTED OTHERWISE. MOUNT .AT 48" A.F.F. 2. SNAP SWITCHES USED TO CONTROL OUTLETS / RECEPTACLES SHALL BE OF THE HEAVY-DUTY TYPE RATED AT THE VOLTAGE / AMPERAGE INDICATED IN PLANS AND DIAGRAMS AND SHALL BE FUTHER QUALIFIED TO CONTROL MOTOR LOADS UP TO 2.0 HORSEPOWER, UNLESS OTHERWISE NOTED. SWITCHES AND COVER PLATES SHALL BE PASS AND SEYMOUR OR EQUAL. F. ALL SWITCH AND OUTLET COVER PLATES TO BE BRUSHED STAINLESS STEEL. G. BLANK, TELEVISION AND TELEPHONE OUTLETS: 4" SQUARE EXTRA DEEP BOX, SINGLE GANG RING AND BLANK COVER PLATE. PROVIDE CONDUIT FROM EACH BOX INTO AN ACCESSIBLE SPACE. TERMINATE CONDUIT WITH INSULATED CONNECTORS ON BOTH ENDS. XII. ENCLOSED DISCONNECT SWITCHES A. ELECTRICAL COMPONENTS, DEVICES, AND ACCESSORIES: LISTED AND LABELED AS DEFINED IN NFPA 70, ARTICLE 100, BY A TESTING AGENCY ACCEPTABLE TO AUTHORITIES HAVING JURISDICTION, AND MARKED FOR INTENDED USE. B. NONFUSIBLE SWITCH: TYPE GD WITH LOCKABLE HANDLE. C. FUSIBLE SWITCH: TYPE HD WITH CLIPS TO ACCOMMODATE FUSES. HANDLE LOCKABLE IN OPEN AND CLOSED POSITION. HANDLE INTERLOCKED WITH COVER IN CLOSED POSITION WITH INTERLOCK BYPASS. D. ENCLOSURES: NEMA AB 1 AND NEMA KS 1 TO MEET ENVIRONMENTAL CONDITIONS OF INSTALLED LOCATION. 1. OUTDOOR LOCATIONS: NEMA 250 TYPE 3R. 2. KITCHEN AREAS. NEMA 250 TYPE 4X, STAINLESS STEEL 3. OTHER WET OR DAMP INDOOR LOCATIONS: NEMA 250 TYPE 4. 4. HAZARDOUS AREAS INDICATED ON DRAWINGS: NEMA 250 TYPE 7C E. MANUFACTURER'S STANDARD PRIME -COAT FINISH READY FOR FIELD PAINTING. F. LABEL EACH ENCLOSURE WITH ENGRAVED METAL OR LAMINATED -PLASTIC NAMEPLATE MOUNTED WITH CORROSION -RESISTANT SCREWS. G. INSTALL EQUIPMENT GROUNDING CONNECTIONS FOR SWITCHES AND CIRCUIT BREAKERS WITH GROUND CONTINUITY TO MAIN ELECTRICAL GROUND BUS. H. DEMONSTRATE PRODUCT CAPABILITY AND COMPLIANCE WITH REQUIREMENTS AFTER INSTALLATION AND AFTER ELECTRICAL CIRCUITRY HAS BEEN ENERGIZED. 1. PERFORM VISUAL AND MECHANICAL INSPECTION AND ELECTRICAL TEST. CERTIFY COMPLIANCE WITH TEST PARAMETERS. 2. CORRECT MALFUNCTIONING UNITS, ON -SITE WHERE POSSIBLE, AND RETEST TO DEMONSTRATE COMPLIANCE. XIII. PANELBOARDS A. MANUFACTURER: CUTLER HAMMER, GENERAL ELECTRIC, SIEMENS, SQUARE D B. CABINET 1. NEMA 1 CABINET, CODE GAUGE STEEL CONSISTING OF A BOX WITH A REMOVABLE FRONT WITH HINGED DOOR AND LATCH. 2. FABRICATE WITH STRAIGHT EDGES AND SQUARE CORNERS. 3. BOXES SHALL BE MINIMUM 20" WIDE. 4. MANUFACTURER'S STANDARD FINISH, PRIME COAT AND BAKED ENAMEL FINISH. C. PROVIDE A NAMEPLATE LISTING OF THE PANEL TYPE AND NUMBER OF PROTECTIVE AND SWITCHING DEVICES AND RATINGS. D. BUS BARS FOR THE MAINS SHALL BE COPPER SIZED IN ACCORDANCE WITH UL STANDARDS. INCLUDE FULL SIZE NEUTRAL BARS UNLESS OTHERWISE NOTED. PROVIDE GROUND BUS. E. NEUTRAL BUSSING SHALL HAVE ONE LUG FOR EVERY BRANCH CIRCUIT THAT THE PANELBOARD IS CAPABLE OF SUPPORTING. F. BUS SPACES FOR FUTURE SWITCHING AND PROTECTIVE DEVICES FOR THE MAXIMUM DEVICES AND SWITCHES THAT THE PANELBOARD CAN ACCOMMODATE. G. CIRCUIT BREAKERS: 1. UNLESS INDICATED OTHERWISE, CIRCUIT BREAKERS SHALL BE BOLT -ON, INDIVIDUALLY REPLACEABLE, THERMAL -MAGNETIC, AUTOMATIC FREE TRIPPING, SEPARATELY INDICATING "ON", "TRIPPED", AND "OFF", AMBIENT COMPENSATED AT 40 DEGREES C., SINGLE, DOUBLE, OR TRIPLE POLE, AS REQUIRED BY THE PANEL SCHEDULES. 2. CIRCUIT BREAKERS INDICATED AS MULTIPLE POLE SHALL BE COMMON TRIP. 3. SHUNT TRIP BREAKERS SHALL HAVE INTEGRAL RELAYS. XIV. FIRE ALARM SYSTEM A. MANUFACTURERS: EXISTING FIRE ALARM PANEL. CONTRACTOR TO FIELD VERIFY MANUFACTURER. B. CONTRACTOR SHALL PROVIDE ALL REQUIRED STATE AND/OR LOCAL SUBMITTALS FOR FIRE ALARM INSTALLATION, AND INCLUDE ALL ASSOCIATED PLAN APPROVAL FEES. C. FIRE ALARM CONTRACTOR IS RESPONSIBLE FOR FINAL DESIGN AND LAYOUT OF DEVICES TO MEET CODE. D. QUALITY ASSURANCE 1. EQUIPMENT AND INSTALLATION SHALL CONFORM TO THE NFPA 72. NEC, AND LOCAL AUTHORITIES HAVING JURISDICTION. 2. ALL FIRE ALARM EQUIPMENT AND INSTALLATION SHALL COMPLY WITH THE AMERICANS WITH DISABILITIES ACT (ADA) REQUIREMENTS. 3. ALL TECHNICIANS PERFORMING WORK ON THIS PROJECT SHALL BE FACTORY TRAINED AND AT MINIMUM, NICET LEVEL TWO CERTIFIED IN FIRE ALARM SYSTEMS. THE SYSTEM'S VENDOR MUST EMPLOY FACTORY TRAINED TECHNICIANS AND MAINTAIN A SERVICE ORGANIZATION WITHIN 100 MILES OF THE JOB SITE, HAVE A MINIMUM OF 10 YEARS EXPERIENCE SERVICING FIRE ALARM SYSTEMS AND PROVIDE 24 HOUR EMERGENCY SERVICE. E. PROJECT CLOSEOUT 1. THE COMPLETED SYSTEM SHALL BE TESTED IN ACCORDANCE WITH NFPA STANDARD 72H. PROVIDE A CERTIFIED TEST REPORT FROM THE MANUFACTURER'S REPRESENTATIVE THAT THE SYSTEM COMPLIES WITH NFPA AND STATE CODES. 2. PROVIDE A "FIRE ALARM SYSTEM RECORD OF COMPLETION" PER NFPA 72, CHAPTER 4. 3. SEE "BASIC ELECTRICAL REQUIREMENTS" FOR OPERATING INSTRUCTION REQUIREMENTS. 4. THE EQUIPMENT AND WIRING SHALL BE WARRANTED TO BE FREE FROM ELECTRICAL AND MECHANICAL DEFECTS FOR A PERIOD OF ONE (1) YEAR. THE YEAR SHALL COMMENCE UPON COMPLETE INSTALLATION AND SUCCESSFUL START-UP OF THE SYSTEM. F. SYSTEM WIRING 1. SEE SCHEMATICS AND DETAILS ON DRAWINGS FOR ADDITIONAL REQUIREMENTS. 2. THE SYSTEM WIRING AND INSTALLATION SHALL BE IN COMPLIANCE WITH APPLICABLE CODES, PROJECT DRAWINGS AND AS REQUIRED BY THE MANUFACTURER. ALL WIRING SHALL BE COLOR CODED, TAGGED AND CHECKED TO ASSURE THAT IT IS FREE FROM SHORTS AND GROUNDS. PROVIDE RECORD DRAWINGS OF INSTALLATION. 3. PROVIDE DUCT SEAL COMPOUND AT EACH SMOKE DETECTOR TO SEAL THE CONDUIT. 4. WHEN CONDUIT AND/OR JUNCTION BOXES ARE REQUIRED BY LOCAL ORDINANCES OR AHJ, PAINT THE BOX COVERS AND CONDUIT BODIES RED AND LABEL "F.A.". G. WHEN REMOTE POWER SUPPLIES ARE REQUIRED, POWER SUPPLIES ARE TO BE MOUNTED IN MECHANICAL ROOMS OR OTHER AREAS ADJACENT TO PANELBOARDS AND WHERE EASILY ACCESSIBLE. PROVIDE BATTERY BACK-UP FOR EACH REMOTE POWER SUPPLY. PROVIDE ONE DEDICATED 120 VOLT BRANCH CIRCUIT PER POWER SUPPLY. INCLUDE COST OF BRANCH CIRCUITS IN BID. H. MULTIPLE ADDRESSABLE PERIPHERAL NETWORK 1. PROVIDE COMMUNICATION WITH ALL INITIATING AND CONTROL DEVICES INDIVIDUALLY AND INDIVIDUALLY ANNUNCIATE AT THE CONTROL PANEL ANNUNCIA11ON SHALL INCLUDE THE FOLLOWING CONDITIONS FOR EACH POINT. a) ALARM b) TROUBLE c) OPEN d) SHORT e) GROUND f) DEVICE FAIL/OR INCORRECT SERVICE/DETECTOR IN NEED OF CLEANING 2. ALL ADDRESSABLE DEVICES CAPABILE OF BEING INDIVIDUALLY DISABLED OR ENABLED. 3. EACH ADDRESSABLE DEVICE MUST BE UNIQUELY IDENTIFIED BY AN ADDRESS CODE ENTERED ON EACH DEVICE AT TIME OF INSTALLATION. 4. THE EQUIPMENT MANUFACTURER SHALL APPROVE WIRING TYPES. I. DEVICES 1. STROBE: a) UL LISTED VANDAL RESISTANT SOLID STATE XENON FLASHTUBE CAPABLE OF EITHER CEILING OR WALL MOUNTING. b) PYRAMIDAL SHAPED LEXAN LENS WITH "FIRE" LETTERING VISIBLE FROM A 180 DEGREE FIELD OF VIEW. c) CANDELA REQUIREMENTS DETERMINED BY CONTRACTOR'S VENDOR. d) STROBE LOCATION ON PLAN IS APPROXIMATE. THE INDICATOR SHALL BE VISIBLE FROM ALL USABLE SPACES WITHIN THE ROOM. MOUNT VISUAL INDICATOR WHERE IT DOES NOT CONFLICT WITH OTHER WALL FINISHES OR EQUIPMENT. e)PROVIDE SYNCHRONIZED STROBES WHERE THREE OR MORE STROBES CAN BE VIEWED FROM ONE LOCATION OR WHERE INDICATED BY AHJ. 2. HORN/ STROBE : a) STROBE AS SPECIFIED ABOVE WITH A COMMON ENCLOSURE FOR THE HORN DEVICE. b) SOUND OUTPUT LEVELS DETERMINED BY CONTRACTOR'S VENDOR. c) EXTERNAL- PROVIDE WEATHERPROOF AUDIBLE / VISIBLE SIGNAL EQUIVALENT TO FARR-LARM SERIES 3300 AT EXTERIOR OF BUILDING NEAR SIAMESE CONNECTION. SHIELD SHALL STATE "WHEN ALARM SOUNDS CALL POLICE OR FIRE DEPARTMENT" OR SIMILAR VERBAGE. 3. SMOKE DETECTORS: a) SMOKE SENSORS SHALL BE SOLID STATE PHOTOELECTRIC SMOKE DENSITY MEASURING DEVICES HAVING NO SELF-CONTAINED ALARM SET POINT (FIXED THRESHOLD) AND SHALL COMMUNICATE ACTUAL CHAMBER VALUES TO THE SYSTEM CONTROL PANEL. b)SMOKE SENSORS AND BASES SHALL BE LISTED TO UL STANDARD 268 AND DOCUMENTED COMPATIBLE WITH THE CONTROL EQUIPMENT TO WHICH THEY ARE CONNECTED, AND FOR BOTH CEILING AND WALL MOUNT APPLICATIONS. c) EACH SENSOR WILL BE CAPABLE OF SENSING UP TO (7) SENSITIVITY LEVELS RANGING BETWEEN .5% AND 3.5X d) PHOTOELECTRIC SENSOR SHALL HAVE A FINE 30 MESH INSECT SCREEN. e) SENSOR ELECTRONICS SHALL BE COMPLETELY SHIELDED TO PROTECT AGAINST FALSE ALARMS FROM EMI AND RFI. f) SMOKE DETECTORS SHALL NOT .BE INSTALLED UNTIL FINAL ROOM FINISHES AND CARPETING HAVE BEEN COMPLETED, OR PROTECT BY A PLASTIC BAG TO PREVENT DUST ENTERING THE SMOKE DETECTOR. 4. HEAT DETECTORS: a) SENSOR SHALL BE A COMBINATION RATE OF RISE/FIXED TEMPERATURE SENSOR. U.L LISTED AS A RATE COMPENSATED HEAT DETECTOR. b)EACH SENSOR CAPABLE OF OPERATING AT A SELECTABLE RATE OF RISE OPERATION OF 15 OR 20 DEGREES FAHRENHEIT PER MINUTE AND IS SELF -RESTORABLE. c) EACH SENSOR CAPABLE OF FIXED TEMPERATURE OPERATION SELECTABLE FOR EITHER 117 OR 135 DEGREES FAHRENHEIT, INDEPENDENT OF THE RATE OF RISE SETTING. d) EACH SENSOR CONFIGURABLE FOR UTILITY MONITORING AND CAPABLE OF SENSING TEMPERATURE BETWEEN 32 AND 158 DEGREES FAHRENHEIT. J. SYSTEM OPERATION 1. PROVIDE REQUIRED PROGRAMMING. VENDOR SHALL MEET WITH THE OWNER TO DETERMINE IF THERE ARE ANY EXTRAORDINARY PROGRAMMING CIRCUMSTANCES. 2. SMOKE DETECTION OPERATION: a) CONTROL PANEL SHALL MAKE THE ALARM DECISION FOR EACH SENSOR. b) CONTROL PANEL SHALL DETERMINE THE CONDITION OF EACH SENSOR BY COMPARING THE SENSOR VALUE TO THE STORED VALUES. c) CONTROL PANEL SHALL MAINTAIN A MOVING AVERAGE OF THE SENSORS' SMOKE CHAMBER VALUE TO AUTOMATICALLY COMPENSATE (MOVE THE THRESHOLD) FOR DUST AND DIRTY CONDITIONS THAT COULD AFFECT DETECTION OPERATIONS. THE SYSTEM SHALL AUTOMATICALLY MAINTAIN A CONSTANT SMOKE OBSCURATION SENSITIVITY FOR EACH SENSOR (VIA THE FLOATING THRESHOLD) BY COMPENSATING FOR ENVIRONMENTAL FACTORS. d) THE SYSTEM SHALL AUTOMATICALLY INDICATE WHEN AN INDIVIDUAL SENSOR NEEDS CLEANING. WHEN A SENSOR'S AVERAGE VALUE REACHES A PREDETERMINED VALUE, A "DIRTY SENSOR" TROUBLE CONDITION SHALL BE AUDIBLY AND VISUALLY INDICATED AT THE CONTROL PANEL. THE LED ON THE SENSOR BASE SHALL GLOW STEADY. IF A "DIRTY SENSOR" IS LEFT UNATTENDED, AND ITS AVERAGE VALUE INCREASES TO A SECOND PREDETERMINED VALUE, AN "EXCESSIVELY DIRECT SENSOR" TROUBLE CONDITION SHALL BE INDICATED AT THE CONTROL PANEL TO PREVENT FALSE ALARMS, THESE "DIRTY CONDITIONS SHALL IN NO WAY DECREASE THE AMOUNT OF SMOKE OBSCURA11ON NECESSARY FOR SYSTEM ACTIVATION. e) CONTROL PANEL SHALL CONTINUOUSLY PERFORM AN AUTOMATIC SELF -TEST ROUTINE ON EACH SENSOR WHICH WILL FUNCTIONALLY CHECK SENSOR ELECTRONICS AND ENSURE THE ACCURACY OF THE VALUES BEING TRANSMITTED TO THE CONTROL PANEL. ANY SENSOR THAT FAILS THIS TEST SHALL INDICATE A "SELF TEST ABNORMAL" TROUBLE CONDITION. f) THE ACTIVATION OF ANY SYSTEM SMOKE DETECTOR IN ALL PUBLIC AND COMMON AREAS SHALL INITIATE AN ALARM VERIFICATION OPERATION WHEREBY THE PANEL WILL RESET THE ACTIVATED DETECTOR AND WAIT FOR A SECOND ALARM ACTIVATION. IF, WITHIN ONE MINUTE AFTER RESETTING, A SECOND ALARM IS REPORTED FROM THE SAME OR ANY OTHER SMOKE DETECTOR, THE SYSTEM SHALL PROCESS THE ALARM AS DESCRIBED PREVIOUSLY. IF NO SECOND ALARM OCCURS WITHIN ONE MINUTE, THE SYSTEM IS TO RESUME NORMAL OPERATION. THE ALARM VERIFICATION OPERATION IS TO BE U.L LISTED. 3. ALARM ACTIVATION a) ANY INITIATION OF SMOKE DETECTORS, PULL STATIONS OR FLOW SWITCHES SHALL PUT THE SYSTEM INTO GENERAL ALARM CONDITIONS. b) EXTERNAL AUDIBLE / VISIBLE SIGNAL AT FIRE DEPARTMENT CONNECTION SHALL ONLY ALARM ON FLOW SWITCH INITIATION. c) ALL AUDIBLE ALARM INDICATING APPLIANCES SHALL SOUND UNTIL SILENCED BY THE ALARM SILENCE SWITCH AT THE CONTROL PANEL. SIGNALS SHALL NOT BE SILENCED DURING ALARM SILENCE INHIBIT MODE. d) XENON STROBES SHALL DISPLAY A CONTINUOUS PATTERN UNTIL SYSTEM IS RESET. 4. SPRINKLER SYSTEM a) COORDINATE THE CONNECTION TO THE SPRINKLER FLOW AND TAMPER SWITCHES WITH THE FIRE PROTECTION CONTRACTOR. PROVIDE ADEQUATE NUMBER OF DRY CONTACTS IN THE SPRINKLER PANEL FOR THE SWITCHES. PROVIDE WIRING FROM THE SPRINKLER PANEL TO THE SWITCHES AND ANNUNCIATORS. 5. MOUNTING HEIGHTS a) FIRE PULL STATION, STROBES AND COMBINATION HORN/STROBE DEVICES: SEE FLOOR PLANS LEGEND FOR MOUNTING HEIGHTS. b) FIRE ALARM REMOTE ANNUNCIATOR PANEL: 48" TO BOTTOM c) FIRE ALARM CONTROL PANEL - MOUNT SUCH THAT THE TOP OF THE FIRE ALARM CONTROL PANEL IS NOT HIGHER THAN 72". FLOOR PLAN GRAPHIC, ADJACENT TO FIRE ALARM ANNUNCIATORS. e 4'-6" 4'-6" 1/2 GAS LINE REDUCED TO 3/8 FMT ON RT OF TABLE TERMINATE PER DETAIL D-13-3/MD. a GUSSET FOR SUPPORT GUSSET FOR SUPPORT 00 00 o0 00 N QUAD OUTLET CO 1/2 COPPER AIR LINE Q 'I 24" AFF TERMINATE PER CO DETAIL D-13A-MD o© 00 QUAD OUTLET 1 1 LAB WORK STATION ELEVATION E O . 2) SCALE: 3/4" = V-0" 4;,12/8/69 C�D'6 J •• H W W o ZZ W 0 Q 100 CAMELOT DRIVE FOND DU LAC, VVI 54935 PHONE: (920) 926-9800 FAX: (920) 926-9801 Always a Better Plan Lf i O Q ~ Y Z Y � W 0 m Q a Y � Z W W .Q W Z U 1.1 Q W 0 V) 00 N N W N I Q W F-- W W D Z W Z W U > Q W CL � J W WJ M J m o m DATE: z Nnv_ 9.-�_ gnnq z JOB NUMBER: Ld 914790 w w Z A2-9 102 A5 SWITCH D A2 V7 EM1 A2 --............ __., 1 A2 A2 A2 XE r— A2 "TCH B A2 n, - - JESS OFFICE 105 EM1 A A2 C5 X—RAY A2 STORAGE 108 A2 A2-5 SWITCH B XE,g TR#1 A2 II TR#2 110 A2 SWI2-3 CH A A2 A2 A2 A2-7 SWITCH C A2 STAFF LOUNGE 120 el '- 11 A3 0 i STERILIZATION 9 Y' A2- 9 S TC D I A2 n4t; A3 A2 I Ell- L_----------- — ' - TR #3 a y I ' aI - XE I 116 EM1 I I ----------- -------- EM1 A2 NowTri FLOOR PLAN - LIGHTING A2 WN II 122 1 A2 A2 fXE LIGHT FIXTURE SCHEDULE TYPE DESCRIPTION VOLT. LAMP MANUFACTURER CATALOG NO. REMARKS QTY. TYPE LAY -IN TROFFERS A2 2X4 LAY -IN TROFFER - ACRYLIC LENS 120V 2 F32T8 LITHONIA 2GT8 232 Al2 GEB 1 A3 2X4 LAY -IN TROFFER - ACRYLIC LENS 120V 3 F32T8 LITHONIA 2GT8 332 Al2 GEB 1 A5 2X2 LAY -IN TROFFER - ACRYLIC LENS 120V 2 F32T8 LITHONIA 2GT8 2U316 Al2 GEB 1 DOWNLIGHTS C5 COMPACT FLUORESCENT CAN 120VI 1 1 F26DTT LITHONIA AF-126DTT-6LD 1 C10 COMPACT FLUORESCENT PARABOLIC CAN 120VI 2 F26DTT LITHONIA / AFZ2-26DTT84A (1) EXITS AND EMERGENCY EM1 WALL CEILING BATTERY EMERGENCY LIGHT 120V - W FIXTURE LITHONIA ELM2 1 XE COMBO SINGLE FACE EXIT W EM HEADS - GREEN LETTERS 120V - W FIXTURE LITHONIA LHQMSW3GELN 1 EXTERIOR LIGHTING WS1 1EXTERIOR WALL SCONCE 120VI 1 1 F32BX KENALL MSIIDSR—ND—PP—MB-32P-1-120 1 — COORDINATE FIXTURE LOCATIONS, CEILING COMPATIBILITY AND TRIM TYPE WITH ARCHITECT'S REFLECTED CEILING GRID. MAKE ADJUSTMENTS TO FIXTURE MODEL AND LAYOUT AS REQUIRED. — BALLAST SHALL HAVE TOTAL HARMONIC DISTORTION (THD) OF 20% OR LESS. UTILIZE BALLASTS WITH 10% OR LESS THD WHERE AVAILABLE FROM MANUFACTURER. — PROVIDE ALL MOUNTING ACCESSORIES, HARDWARE, HANGERS, ETC. NEEDED TO COMPLETE INSTALLATION. — COORDINATE ALL FIXTURE COLORS, PATTERNS, FINISHES WITH ARCHITECT / OWNER PRIOR TO ORDERING. REMARKS: (1) SUBSTITUTES BY COOPER, DAYBRITE, OR HUBBELL SHALL BE EQUIVALENT TO MODEL NUMBER SHOWN, AND APPROVED BY ARCHITECT PRIOR TO SHOP DRAWING SUBMITTAL. EM1 51,14moo "HP1" TC PHOTOEYE CONTROL. LOCATE ON NORTH EXTERIOR OF BUILDING, AIM NORTH. TORK MODEL #EPC1 OR EQUIVALENT. kME TIME CLOCK TO CONTROL (3) #12LIGHTING CONTACTOR. "TORK" MODEL# DGU100 OR EQUIVALENT. (3) #12 SQUARE D CLASS 8903 LB40V01 OR EQUIVALENT CONTACTOR IN NEMA 1 ENCLOSURE BRANCH CIRCUITS) SEE PLAN FOR FEEDER SIZE TO LIGHTS. (TYP.) B2-13 82-17 (BUILDING (BUILDING SIGNAGE) LIGHTS) EXTERIOR LIGHTING CONTROL DETAIL NO SCALE LIGHTING PLAN NOTES: • ALL BALLASTS SHALL BE LOW HARMONIC TYPE. • FIXTURE SHADING INDICATES THAT FIXTURE SHALL BE ON NIGHT LIGHT CIRCUIT. • COORDINATE LIGHTING LAYOUT WITH ARCHITECT'S REFLECTED CEILING PLAN AND ADJUST LAYOUT ACCORDINGLY. • E.C. SHALL PROVIDE ALL APPURTENCES AND ACCESSORIES INCLUDING, BUT NOT LIMITED TO, PHOTOCELLS, CONTACTORS, SWITCHES, STEMS, HANGERS, ETC., IN ORDER TO PROVIDE A COMPLETE AND OPERABLE SYSTEM. • COORDINATE FIXTURE LOCATIONS AND MOUNTING ASSEMBLIES WITH OTHER TRADES AND TYPE OF CONSTRUCTION TO ENSURE ADEQUATE MOUNTING. • ALL TYPE "X1C", "XE", AND "EM1" EMERGENCY LIGHTS ARE TO BE PROVIDED WITH 90 MINUTE BATTERY BACK—UP. BATTERY CHARGER TO BE CIRCUITED TO UNSWITCHED LEG OF LOCAL LIGHT CIRCUIT. O LIGHTING PLAN KEYED NOTES: 1. CIRCUIT AND SWITCH LIGHTS ALONG WITH OTHER LIGHTS FROM SWITCH OUTSIDE RECEPTION AREA. USE SWITCH IN THE SPACE FOR LOCAL DAYTIME LIGHTING OR FAN CONTROL. 2. CIRCUIT NIGHT LIGHT TO UNSWITCHED LEG OF LOCAL LIGHT CIRCUIT. 3. PROVIDE SWITCH BANK AT 48" A.F.F. LETTER AT CIRCUIT DESIGNATION INDICATES SWITCH ASSIGNMENT. 4. SEE ARCHITECTURAL ELEVATIONS FOR FINAL LOCATIONS AND MOUNTING HEIGHTS. 5. E.C. SHALL CONNECT EXISTING EXTERIOR REMOTE LIGHTING FIXTURE TO NEW "XE" FIXTURE. COORDINATE LOCATION OF ALL EXPOSED CONDUIT WITH OWNER PRIOR TO INSTALLATION, N Q w H w w H � Z Z w w U > w a n � J J J � ZJ J U w J J w o = = ry Z m o m CL 0 w I-, w CL Q N !`�_ N SHEET ISSUE: NOVEMBER 23, 2009 SEE TITLE SHEET TO CONFIRM THAT THIS SHEET HAS BEEN RELEASED FOR CONSTRUCTION REVISIONS: DATE: z NOV. 23, 2009 z JOB NUMBER: w 914790 w z 4x4 POST (6) #12 WIRES RUN TO MASTER CONTROL, LOCATED OUTSIDE OF X-RAY ROOM SEE DETAIL D9A ON SHEET MD 3/4" PLYWOOD 4x4 JBOX MOUNTED 42" A.F.F. TO BOTTOM, CENTERED BETWEEN 4x4 POST o ~ _4 5/8" GWB BOTH SIDES DOUBLE GWB - - - INSIDE OF ROOM 0 X-RAY SUPPORT TO WITHSTAND 1500 LBS. OF OUTWARD PULL. INSTALLATION BEHIND FINISHED SURFACES. FOLLOW ANY AND ALL VARIATIONS REQUIRED FOR LOCAL BUILDING AND X-RAY RADIATION CONTROL STANDARDS. Qc C\ (2) LAYERS 3/4" PLYWOOD 20 GAUGE STEEL WALL STUDS (16" O.C.) DEDICATED 20 AMP 220V ELEC. CIRCUIT TWIST LOCK OUTLET (ELECTRICIAN TO SUPPLY MALE END) (CENTERED IN ROOM) PLASTER RING WITH 2" CONDUIT OR WALL CHASE RAN ABOVE CEILING WITH PULL STRING (CENTERED IN ROOM) 5/8" GWB BOTH SIDES DOUBLE GWB INSIDE OF ROOM NORTH EXISTING RTAC EXISTING RTAC EXISTING FLOW AND TAMPER SWITCHES FLOOR PLAN - POWER EXISTING FACP S END OF LINE RESISTOR (2)#12 END OF LINE S RESISTOR (2)#12 FIRE ALARM NOTES - SEE FLOOR PLANS AND SPECIFICATIONS FOR (2)#.14 DEVICE QUANTITIES AND EQUIPMENT REQUIRED. - PROVIDE BOXES FOR ALL DETECTORS PER MANUFACTURERS REQUIREMENTS. - FIELD VERIFY EXISTING FACP MANUFACTURER. SMOKE DETECTOR & ADDRESSABLE MODULE POWER SUPPLY (2)#12. ADDRESSABLE FIRE ALARM SCHEMATIC NO SCALE POWER PLAN NOTES: • ALL CONDUITS STUBBED OUT OF BUILDING SHALL BE DONE PER CONDUIT PENETRATION DETAIL/SHEET EO.2 • ALL RECEPTACLES LOCATED IN TOILET ROOMS, WITHIN 6'-0" OF SINKS OR QQ SERVING COUNTERTOPS SHALL BE GFCI TYPE. • COORDINATE ALL RECEPTACLE, DATA AND TELEPHONE PORT LOCATIONS WITH EXCEL FURNITURE LAYOUT AND OWNER'S FURNITURE SUPPLIER PRIOR TO ROUGH -IN. E N G I N E E RI N G inc. • COORDINATE THE VOLTAGE, AMPERAGE, PHASE, CONNECTION TYPE, ROUGH -IN LOCATION, ETC. OF ALL EQUIPMENT WITH THE CONTRACTOR INSTALLING THE EQUIPMENT. 100 CAMELOT DRIVE FOND DU LAC, WI 54935 • FIRE ALARM SYSTEM INSTALLATION AND WIRING SHALL BE PER NFPA PHONE: (920) 926-9800 REGULATIONS AND LOCAL FIRE DISTRICT REQUIREMENTS. FAX: (920) 926-9801 • REFER TO ASPEN DENTAL MANAGEMENT, INC. UNDERGROUND LAYOUT DRAWING FOR EXACT LOCATION(S) OF ALL UNDERGROUND UTILITIES. Always a Better Plan O POWER PLAN KEYED NOTES: 1. PROVIDE REVERSE ACTING THERMOSTAT TO TURN ON CEF-3 ON A RISE IN r11_ TEMPERATURE ABOVE 807. MOUNT AND WIRE THERMOSTAT. Lf) 2. PROVIDE TWO (2) 120V, 10, 20 AMP DOUBLE DUPLEX RECEPTACLES AT 44" M A.F.F. AT LOCATIONS INDICATED FOR EQUIPMENT IN TELEPHONE CABINET. Q LOCATE RECEPTACLES AS TIGHT TOGETHER AS POSSIBLE. 3. EXISTING RELOCATED PANELBOARD "A2". PROVIDE NEW BREAKERS AS SHOWN Z Y ry IN PANEL SCHEDULE. L Q O 4. PROVIDE RELAY IN NEMA 1 ENCLOSURE TO INTERLOCK CIRC PUMP. CONNECT W 0- TO LIGHT CIRCUIT CONTROLLED BY SWITCH "D". ?) Q Y Ld5. FURNISH AND INSTALL 208V, 2-POLE, 30 AMP NEMA 1 FUSED DISCONNECT FOR Z LL1 Z VACUUM SYSTEM. PROVIDE WITH FRN8 FUSES. Q W M ry 6. PROVIDE 2'-0" x 4'-0" x 3/4" "AB" GRADE PLYWOOD TELEPHONE BACKBOARD U Li FOR TELEPHONE EQUIPMENT. Q cn 7. JUNCTION BOXES AND RECEPTACLES LOCATED IN MILLWORK SHALL BE LdU FURNISHED AND INSTALLED BY THE MILLWORK CONTRACTOR AND WIRED BY THE z Ld Id < ELECTRICAL CONTRACTOR. W Ld Z 8. FURNISH AND INSTALL CONNECTIONS TO OWNER SIGNAGE. PROVIDE JUNCTION Z Q BOX(ES) AND ASSOCIATED 120V, 10, 20 AMP CIRCUIT FOR SIGNAGE. FIELD Z N VERIFY EXACT ROUGH -IN LOCATION. PROVIDE TIMECLOCK FOR CONTROL. SEE Li l ~ EXTERIOR LIGHTING CONTROL DETAIL SHEET E1.1L. COORDINATE WITH OWNER / O V) 00 Q LANDLORD. Q N W 9. PROVIDE 120V, 10, 20 AMP QUAD RECEPTACLE FOR X-RAY COMPUTER AND CONTROLS, SEE DETAIL #08/ SHEET A5.0. 10. FURNISH AND INSTALL PLASTER RING INSIDE UTILITY CENTER AND 2" CONDUIT OR WALL CHASE EXTENDING ABOVE CEILING. N 11. FURNISH AND INSTALL PLASTER RING INSIDE UTILITY CENTER AND 2" CONDUIT EXTENDED BELOW GRADE TO CENTER ISLAND AND LOOPED TO STATION. Q 12. FURNISH AND INSTALL DOUBLE GANG EXTRA DEEP JUNCTION BOX AT 44" A.F.F. Ld WITH 1" CONDUIT AND BUSHING. EXTEND ABOVE CEILING. 13. ELECTRICAL CONTRACTOR TO PROVIDE RECEPTACLES IN UTILITY STATIONS IN V) ACCORDANCE WITH THE DENTAL EQUIPMENT SUPPLIER'S DETAILS. PROVIDE HOSPITAL GRADE RECEPTACLES WHERE REQUIRED BY CODE. SEE DETAIL Ld Ld #D-3/ SHEET MD. F-- =) Z z 14. ELECTRICAL CONTRACTOR SHALL PROVIDE ELECTRIC HAND DRYER, JUNCTION W Lj BOX AND ASSOCIATED 120V, 10, 20 AMP CIRCUIT. TOP OF CONTROLS AND AIR U > DISCHARGE TO BE A MAXIMUM OF 48" A.F.F. DRYER SHALL BE EQUIVALENT TO W Q DAYTON #5W63. Ld n J 15. FURNISH AND INSTALL DUPLEX RECEPTACLE AND PLASTER RING WITH PULL :D J STRING ABOVE CEILING AT 60" A.F.F. FOR PLASMA TV. I 0 Q 16. PROVIDE 208V, 2-POLE, 20 AMP CIRCUIT AND RECEPTACLE TO SERVE cn cn STERILIZER (NEMA6 20P). Z r, J J M Ld 17. 2" CONDUIT BELOW FINISHED GRADE. USE UNDERGROUND LAYOUT DRAWING PROVIDED BY ASPEN DENTAL FOR EXACT CONDUIT LOCATION. Z I 18. INSTALL JUNCTION BOX OR PLASTER RING 18" A.F.F. WITH 2" CONDUIT RUN TO O LLI = i- 2 ABOVE CEILING. REFER TO DETAIL #2/SHEET E1.1P. CL 0- W (/) L,J O o- I-, LLI 19. PROVIDE 220V, 20 AMP RECEPTACLE TO SERVE X-RAY EQUIPMENT. 1••� ELECTRICAL CONTRACTOR TO SUPPLY MALE END. COORDINATE RECEPTACLE AND CONNECTION REQUIREMENTS WITH EQUIPMENT PROVIDER (NEMA 6-20P). LEAVE MALE END TAPED TO OUTLET. REFER TO DETAIL #2/SHEET E1.1P. SHEET ISSUE: 20. DATA WIRING SHALL BE RUN UNDERGROUND BY OTHERS IN 1" CONDUIT FURNISHED AND INSTALLED BY THE ELECTRICAL CONTRACTOR. POWER SHALL NOVEMBER 23, 2009 BE RUN UNDERGROUND IN CONDUIT FROM FULL HEIGHT WALL TO HALF WALL. SEE TITLE SHEET TO CONFIRM THAT THIS SHEET HAS BEEN 21. FURNISH AND INSTALL 208V, 30, 50 AMP, NEMA 1 DISCONNECT FOR WATER RELEASED FOR CONSTRUCTION HEATER. PROVIDE ELECTRICAL CONNECTIONS TO WATER HEATER IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. `' REVISIONS COORDINATE MOUNTING LOCATION WITH EQUIPMENT IN ROOM. 22. ELECTRICAL CONTRACTOR SHALL FLUSH MOUNT 2-GANG BOX AT 60" A.F.F. TO CENTERLINE. ROUTE CONTROL WIRES FROM 2-GANG BOX LOCATION TO EQUIPMENT ROOM AND MAKE FINAL CONNECTION. SEE DETAIL #D32A/ SHEET MD. CONTROL PANEL PROVIDED BY EQUIPMENT SUPPLIER. 23. FURNISH AND INSTALL JUNCTION BOX FOR REMOTE X-RAY HEAD CONTROL WIRING. SEE DETAIL #1/SHEET E1.1P. 24. PROVIDE JUNCTION BOX AND CIRCUIT FOR REMOTE X-RAY CONTROLS. SEE DETAIL #D-9A/ SHEET MD. 25. PROVIDE JUNCTION BOX FOR X-RAY CONTROL BOX ASSEMBLY. SEE DETAIL #D-9D/ SHEET MD. 26. PROVIDE 208V, 2-POLE, 20 AMP CIRCUIT AND RECEPTACLE TO SERVE AIR COMPRESSOR. VERIFY PLUG TYPE WITH EQUIPMENT SUPPLIER (NEMA 6-20R). DATE: 27. FANS ARE TO BE PROVIDED AND INSTALLED BY THE MECHANICAL CONTRACTOR Z NOV. L 3 ZOO 9 AND WIRED BY THE ELECTRICAL CONTRACTOR. SEE FAN SCHEDULE FOR - ADDITIONAL INFORMATION. z JOB NUMBER: 28. NEW PANELBOARD PER SPECIFICATIONS FED FROM EXISTING PANEL "A2". H `7 1,47 q In NORTH DEMOL FLOOR TI ON PLAN SCALE: 1 /4" = 1'-0" NOTES: - REMOVE ALL DUCTWORK AND GRILLES ASSOCIATED WITH THE EXISTING RTAC UNITS TO THE UNIT DROPS THRU THE ROOF. - PROVIDE "SYSTEM SENSOR' DH100ACDC DUCT SMOKE DETECTORS IN THE RETURN DROPS, H.C. TO INSTALL AND WIRE TO SHUT DOWN UNIT UPON DETECTION OF SMOKE. EXCEL ENGINEERWG;nc. 100 CAMELOT DRIVE FOND DU LAC, WI 54935 PHONE: (920) 926-9800 FAX: (920) 926-9801 Always a Better Plan U,7 O � M Q ~ Z Y Y ry w 12 ry Q 0 w n < ICI z Q w w z U w J (n .. r i- Z n w U Q W w o o z ry >- Z z < V) w 0 CL cn 00 Q Q N w N I Q w V) w Li Z Lw Z w U w > Q n D J J J J < •• I'— Z J r- J U w J M J W o = ry = ry ry 0- o IL o- v� w w SHEET ISSUE: DATE: Z NOV. 23, 2009 z JOB NUMBER: W 914790 W W Z w SHFFT H D 1 .1 DUCTWORK AND DUCTWORK INSULATION SCHEDULE SERVICE MAT'L SMACNA PRESS. CLASS INSULATION INSUL JACKET RECTANGULAR DUCT ROUND DUCT SUPPLY DUCTWORK GALV. ST +1" 1.5" FLEX F.G. 1.5" FLEX. F.G. N.R. RETURN GALV. ST. -1" 1.5" FLEX. F.G. N.R. N.R. EXHAUST DUCTWORK GALV. ST. -1" 1.5" FLEX. F.G. 1 1.5" FLEX. F.G. 1 N.R. N.R. = NOT REQUIRED MATERIALS: GALV. STEEL: ASTM A525 AND 527, LOCK FORMING QUALITY, 1.25 OUNCES PER S.F. ZINC COATING (G90 IN ACCORDANCE WITH ASTM A90 BOTH SIDES OF SHEET). - ALL JOINTS, LONGITUDINAL AND TRANSVERSE SEAMS AND CONNECTIONS IN DUCTWORK SHALL BE SEALED PER IECC 503.2.7. (1) INSULATE FROM 18" UPSTREAM OF THE BACKDRAFT OR MOTOR OPERATED DAMPER TO THE POINT WHERE THE DUCT EXITS THE BUILDING. ROOF CAP SCHEDULE NO. SERVICE TYPE THROAT CFM APD. SCREEN DAMPER MODEL REMARKS 1 EXHAUST FLAT 6 100 0.01 BIRD NO RCC-7 1 "GREENHECK" 2 EXHAUST FLAT 10 500 0.06 BIRD NO GRS-10 1 "GREENHECK" - ACCEPTABLE MANUFACTURERS: GREENHECK, CARNES (1) PROVIDE ROOF CURB. SUPPLY GRILLE SCHEDULE (S.G.) NO. CFM RANGE NECK SIZE MAIL DAMPER FINISH FRAME THROW MODEL REMARKS 1-6 0-125 6" ALUM. YES 1 LAY -IN 2 3 TMS-AA "TITUS" 1-8 126-275 8" ALUM. YES 1 LAY -IN 2 3 TMS-AA "TITUS" 1-10 276-375 10" ALUM. YES 1 LAY -IN 2 (3) TMS-AA "TITUS" 1-12 375-550 12" ALUM. YES 1 LAY -IN 2 3 TMS-AA "TITUS" - ACCEPTABLE MANUFACTURERS: KRUEGER, CARNES, SHOEMAKER. - PROVIDE R-6 MOLDED FOIL BACKED INSULATION BLANKET. - BRANCH DUCT SIZE TO GRILLE SHALL BE SAME SIZE AS NECK UNLESS OTHERWISE NOTED. (1) WHITE. PROVIDE MANUFACTURER'S COLOR CHART WITH SHOP DRAWING SUBMITTAL VERIFY COLOR SELECTIONS WITH OWNER / ARCHITECT PRIOR TO PURCHASE. (2) COORDINATE MOUNTING WITH ARCHITECTURAL PLANS. PROVIDE PLASTER RINGS WHERE REQUIRED FOR INSTALLATION. (3) NUMBER OF THROW DIRECTIONS INDICATED ON PLAN BY GRILLE SHADING. SHADED QUADRANT DOES NOT HAVE AIRFLOW. RETURN GRILLE SCHEDULE (R.G.) NO. TYPE CFM RANGE NECK SIZE FLEX. DUCT. DIA. MAT'L DAMPER FINISH FRAME MODEL REMARKS 1-6 EGG CRATE 0-75 24 x 24 6" ALUM. YES 1 LAY -IN 2 50F "TITUS" 1-8 EGG CRATE 76-275 24 x 24 8" ALUM. YES 1 LAY -IN 2 50F "TITUS" 1-10 EGG CRATE 276-450 24 x 24 10" ALUM. YES 1 LAY -IN (2) 50F "TITUS" 1-12 EGG CRATE 451-750 24 x 24 12" ALUM. YES 1 LAY -IN 2 50F "TITUS" 1-14 EGG CRATE 751-1100 24 x 24 14" ALUM. YES 1 LAY -IN 2) 50F "T1TUS" - ACCEPTABLE MANUFACTURERS: KRUEGER, CARNES, SHOEMAKER. - BRANCH DUCT SIZE TO GRILLE SHALL BE SAME SIZE AS NECK UNLESS OTHERWISE NOTED. (1) WHITE. PROVIDE MANUFACTURER'S COLOR CHART WITH SHOP DRAWING SUBMITTAL VERIFY COLOR SELECTIONS WITH OWNER / ARCHITECT PRIOR TO PURCHASE. (2) COORDINATE MOUNTING WITH ARCHITECTURAL PLANS. PROVIDE PLASTER RINGS WHERE REQUIRED FOR INSTALLATION. ELECTRICAL/STARTER/DISCONNECT SCHEDULE SYM. LOCA11ON ELECTRICAL DATA STARTER DISCONNECT REMARKS HP KW MCA MOP VOLT PH. TYPE LOCATION FURN. BY AUX. CONTACT ACCESS- ORIES DIS- CONNECT FURN. BY RTAC-3 ROOF - - 22.4 25 208 1 INTEG. INTEGRAL EM - R, WP EM CEF-1 TOILET RM - 0.08 - - 120 1 1 1 EC - - R EM CEF-2 TOILET RM - 0.08 - - 120 1 1 1 EC - - R EM CEF-3 LAB - 0.23 - - 120 1 1 1 EC - - R EM CEF-4 MECH RM - 0.08 - - 120 1 2 2 EM - - R EM STARTER TYPE: INTEG.= INTEGRAL: PROVIDED INTEGRAL WITH EQUIPMENT. FURNISHED BY: DISCONNECT: EM = EQUIPMENT MANUFACTURER NR= NOT REQUIRED HC = HEATING CONTRACTOR R = REQUIRED EC = ELECTRICAL CONTRACTOR WP= WEATHERPROOF REMARKS: H.W.= HARD WIRED REC.=RECEPTACLE - ACCEPTABLE MANUFACTURERS: ALLEN BRADLEY, CUTLER HAMMER, SQUARE D, GENERAL ELECTRIC. - VERIFY VOLTAGE AND PHASE WITH ELECTRICAL CONTRACTOR BEFORE ORDERING EQUIPMENT. - FURNISH MOTOR STARTERS TO E.C. FOR INSTALLATION AND WIRING WHEN THE STARTER SCHEDULE CALLS FOR H.C. TO FURNISH. (1) FAN WIRED TO ROOM WALL SWITCH. (2) FAN WIRED TO REVERSE ACTING THERMOSTAT BY E.C.. EXISTING ROOFTOP AIR CONDITIONING UNIT SCHEDULE (R.T.A.C.) NO. SUPPLY FAN COOLING HEATING MODEL REMARKS -5!91 O.A. CFM EXT. S.P. RPM MOTOR HP MBH CAP. AMB. TEMP NO. COMPR. STAGES ELECTRIC KW MBH IN MBH OUT NO. STAGES 1 2,000 225 0.6 - 1.50 60.9 95 2 2 7.9 - - 2 50TFF006 CARRIER 2 2,000 195 0.6 - 1.50 60.9 95 2 2 7.9 - - 2 50TFF006 CARRIER - PROVIDE WITH NEW 2" ASHRAE STD 52.2 MERV 8 T.A. FILTERS - THE ABOVE INFORMATION IS BASED ON ORIGINAL BUILDING DESIGN DOCUMENTS AND MAY NOT REFLECT THE ACTUAL UNITS INSTALLED. FIELD VERIFY. CABINET EXHAUST FAN SCHEDULE (C.E.F.) NO. AREA SERVED TYPE CFM S.P. " W.C. RPM MOTOR WATTS MAX. SONES DUCT COLLAR SIZE MODEL REMARKS 1 TOILET RM CEILING 100 0.38 950 80 2.7 6" SP-B110 "GREENHECK" 2 TOILET RM CEILING 100 0.38 950 80 2.7 6" SP-B110 "GREENHECK" 3 LAB CEILING 300 0.50 1070 224 4.5 8 x 8 SP-A510 "GREENHECK" 4 MECH RM CEILING 100 0.38 950 80 2.7 6" SP-B110 "GREENHECK" - ACCEPTABLE MANUFACTURERS: GREENHECK, COOK, PENN, CARNES. - SUPPORT FROM STRUCTURE, ISOLATE FAN AND ASSOCIATED DUCTWORK. - PROVIDE SPEED CONTROL MOUNTED ON FAN HOUSING. - INTERNAL PLUG-IN DISCONNECT AND BACKDRAFT DAMPER. - PROVIDE WITH WHITE GRILLE. ROOFTOP AIR CONDITIONING UNIT SCHEDULE (R.T.A.C.) NO. SUPPLY FAN RELIEF FAN BAROM. RELIEF COOLING HEATING OUTSIDE AIR SMOKE DETECTOR CURB MCA MOP VOLT PHASE EFFICIENCY WEIGHT (LBS.) REFR. MODEL REMARKS CFM O.A. CFM EXT.. S.P. RPM MOTOR HP MOD. TYPE RPM MOTOR HP MOD. TYPE EAT F DB LAT F DB WB MBH CAP. AMB. TEMP F NO. COMPR. STAGES ELECTRIC KW MBH IN MBH OUT NO. STAGES HEIGHT BY MFR. TYPE MIN. CODE UNIT RATING TEST PROC. 3 p 800 60 0.5" 761 1 2 - - - - - 89 67 58 56 20.5 105 1 1 3.3 - - 1 MINIMUM POSITION YES 2 14" STANDARD 22.4 25 208 1 9.7 SEER 14.1 SEER ARI 210 240 900 R-22 50HE-003 CARRIER - ACCEPTABLE MANUFACTURERS: TRANE, CARRIER, MCQUAY, YORK, LENNOX. USE OF MANUFACTURER OR MODEL OTHER THAN LISTED IN SCHEDULE ABOVE SHALL BE CONSIDERED A SUBSTITUTION. DRAWINGS SHOWING REVISED DUCT ROUTING, ROOF OPENINGS, STRUCTURAL STEEL, ETC. WILL BE REQUIRED AT TIME OF RTAC SHOP DRAWINGS SUBMITTAL. - SEE MOTOR SPECIFICATIONS FOR MOTOR REQUIREMENTS. - PROVIDE WITH 2" ASHRAE STD 52.2 MERV 8 T.A. FILTERS (1) PROVIDE UNIT MOUNTED WEATHERPROOF DISCONNECT. (2) PROVIDE FACTORY INSTALLED DUCT SMOKE DETECTOR ("SYSTEM SENSOR" DH100ACDC) IN RETURN AIR SECTION WIRED TO SHUT DOWN SUPPLY FAN ON DETECTION OF SMOKE. HVAC SPECIFICATIONS I. BASIC HVAC REQUIREMENTS A. SEE SHEET T2.0. B. SUBSTITUTIONS: WHERE SUBSTITUTE EQUIPMENT REQUIRES REDESIGN OF ANY PART OF THE PROJECT, THE COST OF REDESIGN AND ADDITIONAL COSTS OF THE WORK SHALL BE PAID BY THE CONTRACTOR. REDESIGN SHALL BE SUBJECT TO THE APPROVAL OF ALL AUTHORITIES HAVING JURISDICTION OVER THE WORK INCLUDING THE ARCHITECT/ENGINEER. C. DETAILS AND SCHEDULES ARE SHOWN TO AID THE CONTRACTOR AND ARE NOT MEANT TO BE INCLUSIVE OF ALL DEVICES. PROVIDE REQUIRED EQUIPMENT AND ACCESSORIES FOR A COMPLETE INSTALLATION. D. INSTALL ALL EQUIPMENT PER MANUFACTURERS INSTALLATION INSTRUCTIONS AND REQUIREMENTS. PROVIDE ADDITIONAL WORK AND MATERIALS AS REQUIRED. E. COORDINATE INSTALLATION OF HVAC WORK WITH THE OTHER CONTRACTORS AND THE EXISTING BUILDING TO AVOID CONFLICTS WITH OTHER WORK. F. PROVIDE ALL CUTTING AND PATCHING NECESSARY FOR HVAC WORK INSTALLATION UNLESS THIS WORK IS IDENTIFIED TO BE THE WORK OF OTHER CONTRACTORS. PATCHING SHALL MATCH ADJACENT SURFACES. G. INSTALL CLEAN SET OF FILTERS IN ALL UNITS AT TIME OF TESTING AND BALANCING. H. CLEAN GRILLES AND EQUIPMENT AND LEAVE IN PROPER WORKING CONDITION AT THE TIME OF FINAL CLEAN-UP. II. FINISH AND PAINTING A. COORDINATE WORK WITH THE PAINTERS SO THAT ALL EQUIPMENT IS INSTALLED PRIOR TO PAINTING. H.C. SHALL PAINT ITEMS IF NOT IN PLACE PRIOR TO NORMAL ROUTINE PAINTING. B. IF FINISH BECOMES RUSTED, CORRODED, SCRATCHED, OR FLAKED DURING STORAGE OR INSTALLATION, REFINISH THE EQUIPMENT TO THE SATISFACTION OF THE OWNER. C. WHERE THE HEATING CONTRACTOR IS REQUIRED TO PAINT, THE PAINTING SHALL BE DONE IN ACCORDANCE WITH THE PAINTING PORTION OF THE ARCHITECTURAL SPECIFICATION. III. INSULATION A. INSULATION SYSTEM SHALL MEET UL-723 REQUIREMENTS OF MAX. FIRE HAZARD CLASSIFICATIONS OF 25, AND MAX. FLAME SPREAD, FUEL CONTRIBUTED, AND SMOKE DEVELOPED OF 50 WHEN INSTALLED IN A RETURN AIR PLENUM. B. INSTALL MATERIALS IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS AND MICA PUBLICATION "COMMERCIAL AND INDUSTRIAL STANDARDS", 1999 FIFTH EDITION. C. CONTINUE INSULATION WITHOUT INTERRUPTIONS THROUGH WALLS, SLEEVES, AND HANGERS. D. FIBERGLASS (F.G.) INSULATION 1. MANUFACTURERS: OWENS CORNING (O.C.) FIBERGLASS CORPORATION, CERTAINTEED, KNAUF, AND JOHNS MANVILLE. 2. FLEX. F.G.: 0.75 LB/CU. FT. GLASS FIBER INSULATION FACTORY LAMINATED TO FRK VAPOR RETARDER. USTED THICKNESS IS NOMINAL, R-3.3 / NOMINAL INCH. E. INSULATE FITTINGS, JOINTS, FLANGES, DAMPERS, AND IN -LINE ACCESSORIES WITHOUT INTERNAL LINING/INSULATION WITH SAME MATERIAL AND THICKNESS AS SPECIFIED FOR THE DUCT SYSTEM. STOP AND POINT INSULATION AROUND ACCESS DOORS AND DAMPER OPERATORS TO ALLOW OPERATION WITHOUT DISTURBING WRAPPING. IV. DUCTWORK A. PERFORM WORK IN ACCORDANCE WITH THE LATEST EDITIONS OF SMACNA HVAC DUCT CONSTRUCTION STANDARDS. B. PAINT THE INSIDE OF ALL DUCTS VISIBLE THROUGH GRILLES OR OTHER OUTLETS WITH DULL BLACK PAINT. C. CERTAIN VERTICAL AND HORIZONTAL OFFSETS ARE INDICATED IN DUCTS TO INDICATE THE GENERAL POSITION RELATIONSHIP OF THE DUCTWORK SYSTEMS; PROVIDE ADDITIONAL OFFSETS AS REQUIRED TO COORDINATE WITH THE INSTALLATION OF OTHER SYSTEMS, COUNGS AND STRUCTURE. THE DRAWINGS ARE DIAGRAMMATIC AND SHALL NOT BE SCALED TO DETERMINE EXACT LOCATION OF DUCTWORK. D. PROVIDE TEMPORARY CLOSURES OF METAL OR TAPED POLYETHYLENE ON OPEN DUCTWORK TO PREVENT CONSTRUCTION DUST FROM ENTERING DUCTWORK SYSTEM. E. LOCATE DUCTS WITH SUFFICIENT SPACE AROUND EQUIPMENT TO ALLOW NORMAL OPERATING AND MAINTENANCE ACTIVITIES. F. INCREASE DUCT SIZES GRADUALLY, NOT EXCEEDING 15 DEGREES WHENEVER POSSIBLE. 30 DEGREE MAXIMUM DIVERGENCE UPSTREAM OF EQUIPMENT; 45 DEGREE MAXIMUM CONVERGENCE DOWNSTREAM. G. ROUND DUCTS MAY BE SUBSTITUTED FOR RECTANGULAR IF SIZED IN ACCORDANCE WITH ASHRAE TABLES OF EQUIVALENT RECTANGULAR AND ROUND DUCTS. H. ROUND DUCTWORK: CONCEALED BRANCH DUCTWORK TO GRILLES AND DIFFUSERS MAY BE LONGITUDINAL LOCKSEAM. ALL OTHER ROUND DUCTWORK SHALL BE SPIRAL LOCKSEAM WITH FITTINGS AND COUPLINGS MINIMUM 2 GAUGES HEAVIER THAN DUCT. I. FLEXIBLE DUCTWORK 1. U.L. 181 USTED CLASS 1 FLEXIBLE AIR DUCT, COMPLY WITH NFPA 90A, FLAME SPREAD OF 25 OR LESS, SMOKE DEVELOPED RATING OF 50 OR LESS. 2. MANUFACTURERS: THERMAFLEX, FLEXMASTER. 3. INSULATED FOR SUPPLY DUCTWORK. UNINSULATED FOR RETURN AND EXHAUST DUCTWORK. 4. CONNECT TO SUPPLY DUCTWORK BY SLIDING CORE OVER COLLAR, TAPE JOINT WITH MINIMUM 3 WRAPS OF TAPE, AND APPLY METAL BAND CLAMP OR PANDUIT. FOR INSULATED DUCTWORK, PULL INSULATION AND OUTER JACKET BACK INTO POSITION, AND TAPE WITH MINIMUM 3 WRAPS OF TAPE BETWEEN FLEX DUCT AND DUCT INSULATION. 5. CONNECT TO GRILLES AND RETURN AND TRANSFER DUCTWORK WITH METAL BAND CLAMP OR PANDUIT 6. MAXIMUM LENGTH FROM DUCTWORK TO GRILLES OR SLOTS 8'-0". 7. DO NOT RUN THROUGH WALLS OR PARTITIONS. J. DUCTWORK SEALANTS 1. MANUFACTURERS: HARDCAST #601, UNITED MCGILL WATER BASED DUCT SEAL. 2. MAXIMUM FLAME SPREAD OF 25, FUEL CONTRIBUTED OF 50, AND SMOKE DEVELOPED OF 50. HARDCAST PS-S TYPE AM-401 TAPE MAY BE USED INSTEAD OF MASTIC TYPE SEALANTS. K. DUCT CLEANING 1. PROTECT DUCTWORK AGAINST ENTRY OF FOREIGN MATTER DURING CONSTRUCTION. PROVIDE TEMPORARY END CAPS AND SEALS. PROVIDE TEMPORARY FILTERS OVER RETURN OR EXHAUST AIR INLETS IF DUCTWORK IS USED DURING CONSTRUCTION. 2. REMOVE ALL DIRT AND FOREIGN MATTER AND CLEAN DIFFUSERS, REGISTERS, AND GRILLES BEFORE OPERATING FANS. L SEAUNG DUCT PENETRATIONS 1. THRU NON -RATED WALLS WHERE DRYWALL, CONCRETE, OR MASONRY EXTENDS TO STRUCTURE, FILL VOID BETWEEN DUCT AND WALL WITH MINERAL WOOL AND CAULK BOTH SIDES WITH NON -HARDENING CAULK. 2. PROTECT PENETRATIONS THRU FIRE -RATED WALLS WITHOUT FIRE DAMPERS WITH A UL APPROVED FIRE -STOP SYSTEM HAVING AN F-RATING NOT LESS THAN THE HOURLY RATING OF THE ASSEMBLY BEING PENETRATED, OR GROUT, CONCRETE, OR MORTAR THE FULL DEPTH OF THE PENETRATED ASSEMBLY WHEN THE ASSEMBLY IS CONSTRUCTED OF CONCRETE OR MASONRY. 3. PENETRATIONS THRU WALLS WITH FIRE DAMPERS INSTALL PER FIRE DAMPER INSTALLATION REQUIREMENTS. V. DUCTWORK ACCESSORIES A. TURNING VANES 1. MANUFACTURERS: AERO/DYNE CO. H.E.P., HART & COOLEY, UNITED MCGILL, SEMCO. 2. RECTANGULAR DUCTWORK: AIRFOIL TURNING VANES IN ACCORDANCE WITH SMACNA FIG. 2-3 AND 2-4. VANE RADIUS AS PROVIDED BY AERODYNE H.E.P. OR 4-1/2 INCHES WITH A 3- 1/2 INCH SPACING. B. MANUAL VOLUME DAMPERS 1. MANUFACTURERS: RUSKIN, VENT PRODUCTS, UNITED MCGILL 2. DAMPERS WITH EXTENDED SHAFTS AND QUADRANTS, OPERATOR WITH LOCKING DEVICE, POSITION INDICATOR, AND ELEVATED PLATFORM FOR EXTERNALLY INSULATED DUCTWORK. 3. RECTANGULAR DAMPERS WHICH DO NOT EXCEED 12" HIGH OR 36" WIDE: BUTTERFLY DAMPER, MINIMUM 22 GAUGE. SHAFT ALONG ENTIRE LENGTH OF DAMPER FOR DAMPERS EXCEEDING 18" IN WIDTH. 4. RECTANGULAR DAMPERS GREATER THAN 12" HIGH OR 36" WIDE: MULTI -BLADE DAMPER WITH CONNECTING LINKAGE TO CONTROL FROM A SINGLE POINT. BLADES MINIMUM 16 GAUGE WITH OPPOSED BLADE ACTION. 5. ROUND DAMPERS: MINIMUM 20 GAUGE BUTTERFLY DAMPER. C. TAKE -OFF FITTINGS 1. MANUFACTURERS: FLEXMASTER, UNITED MCGILL. 2. TO GRILLES: ONE PIECE SPIN -IN WITH INTEGRAL FACTORY INSTALLED LOCKING TYPE BALANCING DAMPERS. D. DUCT ACCESS DOORS 1. MANUFACTURERS: CESCO, FLEXMASTER, VENT PRODUCTS, KEES, UNITED MCGILL, SEMCO. 2. HINGE, LATCHES, HANDLES, AND RUBBER GASKET IN FRAME. 1" INSULATED DOUBLE WALL CONSTRUCTION FOR DOORS IN LINED OR EXTERNALLY INSULATED DUCTWORK. ATTACHMENT CABLES FOR SPIN -IN UNITS. DOOR SUITABLE FOR DUCT STATIC PRESSURE CLASS. 3. DOOR SIZE 2" LESS THAN THE WIDTH OF THE DUCT (MAX. DOOR SIZE 24"X 24" (24" DIA.). 4. ROUND DUCTWORK: 16 GAUGE ROLLED SHEET METAL HINGED ACCESS DOOR WITH BUCKLE LOCKS. 5. PROVIDE AT TURNING VANES IN RETURN AND EXHAUST DUCTWORK, AT ANY DEVICE IN THE DUCT WHICH REQUIRES MAINTENANCE, SERVICE OR CLEANING. 6. USE HINGED ACCESS DOORS WHERE POSSIBLE. USE CAM OPERATED REMOVABLE DOORS WHERE SPACE PREVENTS THE OPENING OF A HINGED MODEL E. FLEXIBLE CONNECTIONS 1. MANUFACTURERS: VENTFABRICS, DURO-DYNE. 2. MATERIAL BOLTED SECURELY TO THE EQUIPMENT AND CONNECTING DUCTWORK WITH #16 GAUGE GALVANIZED IRON BAND (LOOP) CLAMPS BOLTED TIGHT TO MAKE AN AIRTIGHT CONNECTION, MINIMUM 6" WIDE. 3. PROVIDE AT INLET AND OUTLET OF ALL AIR HANDLING UNITS AND FANS IN ACCORDANCE WITH SMACNA FIGURE 2-19. 4. CONVENTIONAL INTERIOR: VENTGLAS, -20 TO 200 DEG F., 30 OZ. PER SQUARE YARD GLASS FABRIC DOUBLE COATED WITH NEOPRENE, UL 214 APPROVED. M. TESTING, ADJUSTING, AND BALANCING A. QUALITY ASSURANCE - PERFORM TOTAL SYSTEM BALANCE IN ACCORDANCE WITH AABC NATIONAL STANDARDS FOR FIELD MEASUREMENT AND INSTRUMENTATION, TOTAL SYSTEM BALANCE OR NEBB PROCEDURAL STANDARDS FOR TESTING, BALANCING AND ADJUSTING OF ENVIRONMENTAL SYSTEMS. B. SUBMITTALS 1. CONTRACTOR SHALL SUBMIT THE FINAL TESTING AND BALANCING REPORT PRIOR TO PROJECT COMPLETION AND IN ADVANCE OF DATE OF OCCUPANCY. SUBMIT REPORTS ON AABC NATIONAL STANDARDS FOR TOTAL SYSTEM BALANCE OR NEBB FORMS. 2. SUBMIT THE DESIGN AND ACTUAL DATA FOR EACH SCHEDULED PIECE OF EQUIPMENT: MODEL; SUPPLY, RETURN, AND OUTSIDE AIR FLOWS; FAN RPM, BHP, AMPERAGE; FAN AND MOTOR SHEAVE, DIAMETER, BORE AND MAKE; BELT SIZE AND QUANTITY, MOTOR SHEAVE CENTER LINE AND OPERATOR DISTANCE; ROOM AIR FLOW. C. QUAUTY ASSURANCE - PERFORM TOTAL SYSTEM BALANCE IN ACCORDANCE WITH AABC NATIONAL STANDARDS FOR FIELD MEASUREMENT AND INSTRUMENTATION, TOTAL SYSTEM BALANCE OR NEBB PROCEDURAL STANDARDS FOR TESTING, BALANCING AND ADJUSTING OF ENVIRONMENTAL SYSTEMS. D. INSTALLATION TOLERANCES 1. AIR HANDLING SYSTEMS: ADJUST SUPPLY SYSTEMS TO WITHIN PLUS OR MINUS 5 PERCENT OF DESIGN AND RETURN AND EXHAUST SYSTEMS TO PLUS OR MINUS 10 PERCENT OF DESIGN. 2. AIR OUTLETS AND INLETS: ADJUST TOTAL AIR FLOW TO SPACE TO WITHIN PLUS 10 PERCENT AND MINUS 5 PERCENT OF DESIGN. 3. ADJUST OUTLETS AND INLETS IN SPACE TO WITHIN PLUS OR MINUS 10 PERCENT OF DESIGN. E. AIR SYSTEM BALANCE 1. VARY TOTAL SYSTEM AIR QUANTITIES BY ADJUSTING FAN SPEEDS. VARY BRANCH AIR QUANTITIES BY DAMPER REGULATION. 2. ADJUST OUTSIDE AIR AND RETURN AIR AUTOMATIC DAMPERS FOR DESIGN CONDITIONS. 100 CAMELOT DRIVE FOND DU LAC, W[ 54935 PHONE: (920) 926-9800 FAX: (920) 926-9801 Always a Better Plan I,,- Lf) O � M Qr z Y � W W ii- 0 Q Nel W Z Q w W Z U LLI J Q V) V) .. cy I- Z ck� W U Q W W o o z z Z Q (/) o W � O EL t/) r 00 V) Q Q N W W V) W H W � z W Z W U > Q Ld W J J J L.i I- Z _J r J V W J .J = 2 oLdmom ry (n W I� W Q N I� N SHEET ISSUE: NOVEMBER 23, 2009 SEE TITLE SHEET TO CONFIRM THAT THIS SHEET HAS BEEN RELEASED FOR CONSTRUCTION REVISIONS: DATE: z Nov_ -i_ gnnc) z JOB NUMBER: 914790 W W Z 0 w SHFF'T J W U X W n[Dao H0. 1 Q 0 N LEGEND NOTE: ALL SYMBOLS SHOWN MAY NOT APPEAR ON DRAWINGS. SYM. ABBR• IDENTIFICATION SYYM ABBR• IDENTIFICATION DUCTWORK RDUCT (R)ISE/(D)ROP ECCENTRIC TRANSITION �+ CONCENTRIC TRANSITION RADIUS ELBOW SQUARE TO ROUND TRANS. SQUARE ELBOW ] DUCT CAP WITH TURNING VANES ALD ACOUSTICALLY LINED DUCT SQUARE ELBOW ---- (NOT ALWAYS SHOWN) WITHOUT TURNING VANES SA SUPPLY AIR DUCT UP SQUARE OR RECTANGULAR BRANCH TAKEOFF OA OUTSIDE AIR DUCT UP RECTANGULAR TO ROUND ® RA RETURN AIR DUCT UP TAKEOFF ® EA EXHAUST AIR DUCT UP BULLHEAD TEE 0 SA OR OA FOR RETURN OR EXHAUST DUCT DOWN OR AWAY 0 EA OR RA BULLHEAD TEE FOR SUPPLY DUCT DOWN OR AWAY RADIUS TEE FC FLEXIBLE CONNECTION MOD MOTOR OPERATED DAMPER �-- VD VOLUME DAMPER ++ BDD BACKDRAFT DAMPER DS DSD DUCT SMOKE DETECTOR I I `' FD FIRE DAMPER SD SMOKE DAMPER FSD FIRE/SMOKE DAMPER ® SG SUPPLY GRILLE E G �T3RANSFER (GRE SRN/ TG No UCD UNDERCUT DOOR (BY GC) —}-► DIG DOOR TRANSFER GRILLE RC REHEAT COIL K AD ACCESS DOOR MISCELLANEOUS AND CONTROLS EQUIPMENT BY OTHERS, AFF ABOVE FINISHED FLOOR BJ BETWEEN JOISTS ■ CONNECTON BY HC CONNECT TO EXISTING HC HEATING CONTRACTOR TJ THRU JOISTS �T THERMOSTAT / TEMP. SENSOR EC ELECTRICAL CONTRACTOR TTS TIGHT TO STRUCTURE GC GENERAL CONTRACTOR TYP. TYPICAL PC PLUMBING CONTRACTOR TV TURNING VANES NIC NOT IN CONTRACT NOTES - MAKE TRANSITION FROM DUCTWORK SIZES SHOWN ON THE THE DRAWINGS TO EQUIPMENT DUCT CONNECTION SIZES. VERIFY EQUIPMENT CONNECTION SIZES IN THE FIELD. ACTUAL EQUIPMENT SIZES SHALL TAKE PRECEDENCE OVER SIZES SHOWN ON PLANS. - IF DUCT SYSTEMS ARE USED FOR TEMPORARY HEAT, PROVIDE TEMPORARY FILTERS AT RETURN AIR OPENINGS AND INSTALL FILTERS IN THE UNITS EQUIVALENT TO THE EFFICIENCY OF THE SPECIFIED FILTERS FOR THE UNIT. IF PROPER EFFICIENCY FILTERS ARE NOT INSTALLED IN UNIT, UNIT AND ALL DUCTWORK DOWNSTREAM OF UNIT SHALL BE CLEANED BEFORE TEST AND BALANCE. - COORDINATE GRILLE LOCATIONS WITH FINAL REFLECTED CEILING PLAN AND CORRESPONDING LIGHTING CONFIGURATION. KEYED NOTES 10 ROOF TOP UNIT PROVIDED BY LANDLORD FOR NEW TENANT CONSTRUCTION. SEE EXISTING RTAC SCHEDULE ON SHEET HOA. FIELD VERIFY EXACT LOCATION OF UNIT AND ADJUST DUCTWORK ACCORDINGLY. CLEAN UNIT, GREASE ALL BEARINGS, LEAK -CHECK AND CHARGE REFRIGERANT SYSTEM, REPLACE FILTERS AT END OF TENANT BUILD -OUT CONSTRUCTION, AND CLEAN OUTDOOR AND INDOOR COILS AND AIR DISTRIBUTION DEVICES. O TRANSITION FROM EXISTING RTAC SUPPLY AND RETURN DUCT SIZES TO SIZE SHOWN ON PLAN. TRANSITION SIZE IN VERTICAL IF TRANSITION CAN MEET SPECIFICATIONS, OTHERWISE TRANSITION AFTER ELBOW. PROVIDE TURNING VANES IN ELBOWS. 30 COORDINATE BUILDING PENETRATION WITH LANDLORD. EXHAUST OUTLET LOCATION MUST BE AT LEAST 10'-0" AWAY FROM ANY OUTSIDE AIR INTAKE. ® MOUNT PROGRAMMABLE THERMOSTAT AT 48 A.F.F. IN LOCATIONS AS SHOWN, UNLESS LOCAL CODE AUTHORITY WILL ALLOW A MOUNTING HEIGHT OF 60 A.F.F. THERMOSTATS WERE PROVIDED UNDER BUILDING SHELL CONSTRUCTION. COORDINATE WITH LANDLORD TO DETERMINE THERMOSTAT TYPE AND CURRENT LOCATION (IF INSTALLED). IN THE EVENT THAT A PROGRAMMABLE THERMOSTAT IS NOT PROVIDED BY THE LANDLORD, THERMOSTATS SHALL BE HONEYWELL VISION PRO 8000 SERIES OR APPROVED EQUAL O5 PROVIDE A LOCKING COVER FOR THE THERMOSTAT LOCATED IN THE RECEPTION AREA. TURN OVER LOCKBOX KEYS TO ASPEN DENTAL MANAGEMENT UPON JOB COMPLETION. 24 GA. SHEET METAL - PLENUM BOX. PAINT INTERIOR BLACK. ACOUSTICALLY LINE AT TRANSFER AND RETURN GRILLES AND PAINT FASTENERS BLACK. MINIMUM 6" DEPTHS GRILLE NECK SIZE RETURN, EXHAUST OR TRANSFER GRILLE FLEXIBLE DUCT (# AS SCHEDULED - EITHER LOCATION) GRILLE PLENUM BOX DETAIL NO SCALE TURNING VANES r I I I I SUPPLY AIR 3 MIN. r = 1.0 W RETURN, EXHAUST OUTSIDE AIR MIN. r = 0.75 W ACCESS PANEL FOR RETURN, EXHAUST, AND OUTSIDE AIR DUCT ELBOW DETAILS NO SCALE NOT PERMITTED NORTH R.T.A.C. BASE, NEOPRENE — GASKET, CURB BY UNIT MFR. ROOFING AND FLASHING BY G.C. ROOF INSULATION ROOF DECK RETURN AIR DUCT - SEE PLAN FOR SIZE AND CONTINUATION Iill.0:%Iezu, 2*99121 FLOOR PLAN SCALE: 1 /4" = 1'-0" (1) LAYER OF 6" FIBERGLASS BATT INSULATION. 3/8" HARDBOARD (ON METAL DECK ONLY) FILL VOID BETWEEN DECK AND DUCT WITH MINERAL WOOL INSUL. FLEX CONNECTION SUPPLY AIR DUCT - SEE PLAN FOR SIZE AND CONTINUATION I:ifrT-01 SHEET METAL ANGLE AROUND DUCTWORK TO ENCLOSE OPENING IN ROOF DECK BY H.C. 3" OF ROOFING BALLAST INSIDE OF CURB BY H.C. CURB FURNISHED BY MFR. INSTALLED BY G.C. SEE SCHED. FOR TYPE AND HEIGHT. INSULATION BY H.C. 2" RIGID 6 PCF FIBERGLASS INSULATION. BLOCKING UNDER CURB BY G.C. AS REQ'D TO RAISE TOP OF CURB HEIGHT ABOVE INSULATION TO ROOFING MFR MINIMUM REQUIREMENTS. NOTE: - G.C. SHALL BLOCK CURB SO TOP OF CURB IS LEVEL TYPICAL RTAC AND CURB DETAIL NO SCALE 100 CAMELOT DRIVE FOND DU LAC, Mn 54935 PHONE: (920) 926-9800 FAX: (920) 926-9801 Always a Better Plan L0 O Q Z Y W O W 12- < Y > Z Q W IJJ Ld Z U Li J V) Z W Q W LI o O Z >_ Z Z a (/ cn W � 0V)00< 0- T-- V) Q N W N I Q W V) W Ld z W Z W U w > Q W D J J W W . • U W J M J Ld >- OLd a_ a_ O IZ SHEET ISSUE: DATE: z NnV_ 9.-�_ gnn9 z JOB NUMBER: W 914790 W Z W SHEET LEGEND NOTE: ALL SYMBOLS SHOWN MAY NOT APPEAR ON DRAWINGS. GYM. ABBR, IDENTIFICATION --- CW COLD WATER PIPING ---- HW HOT WATER PIPING ----- HWR HOT WATER RETURN PIPING -NP- NP NON -POTABLE WATER PIPING - S -- SOFT SOFT WATER PIPING -SA- W WASTE PIPING --SA- SA SANITARY SEWER PIPING SST- ST STORM PIPING ---<)F OF OVERFLOW CONDUCTOR PIPING --- V VENT PIPING VTR VENT THRU ROOF - G - G GAS PIPING - A - A AIR PIPING - V - V VACUUM PIPING CO CLEAN OUT WCO WALL CLEAN OUT -O FCO FLOOR CLEAN OUT (FLUSH) �- BFP BACKFLOW PREVENTER PRV PRESSURE REDUCING VALVE -- SHUTOFF VALVE BALANCE VALVE N CHECK VALVE QWHA WATER HAMMER ARRESTOR r_r TEST CONNECTION PIPING CAP UNION SYM. ABBR.. IDENTIFICATION THERMOMETER PRESSURE GAUGE HB HOSE BIBB RD ROOF DRAIN 0 OF OVERFLOW DRAIN 0 FD FLOOR DRAIN © SD SITE DRAIN O H.O. HUB OUTLET FIXTURE UNIT (WATER SUPPLY OR WASTE) IE INVERT ELEVATION EL ELEVATION RI ROUGH IN ■ EQUIPMENT BY OTHERS. PLUMBING CONNECTION BY PLUMBING CONTRACTOR CONNECT TO EXISTING PIPING ---- REMOVE EXISTING AFF ABOVE FINISHED FLOOR HC HEATING CONTRACTOR EC ELECTRICAL CONTRACTOR FPC FIRE PROTECTION CONTRACTOR GC GENERAL CONTRACTOR PC PLUMBING CONTRACTOR NIC NOT IN CONTRACT BJ BETWEEN JOISTS TJ THRU JOISTS TTS TIGHT TO STRUCTURE TYP. TYPICAL PIPE SCHEDULE j PIPE PIPE SERVICE APPLICATION MATERIAL STANDARD FITTINGS JOINTS WATER ABOVE GROUND ASTM B42, B88 ANSI B16.15, B16.18, INSIDE BUILDING COPPER TYPE L B16.22, 816.23, 916.26 LEAD FREE SOLDER HARD DRAWN B16.29, 916.32 UNDERGROUND ASTM B42, B88 ANSI B16.15, 916.18, AWS A5.8 BCuP INSIDE BUILDING COPPER TYPE K B16.22, B16.23, B16.26 SILVER BRAZE ANNEALED TUBING B16.29 B16.32 1 SAN. SEWER, ABOVE GROUND ASTM D1785, D2665 PVC ASTM F656 SOLVENT DRAIN, WASTE, INSIDE BUILDING PVC DWV ASTM D2466, D2467, WELD WITH ASTM D2564 AND VENT F409 SOLVENT CEMENT HUBLESS ASTM A888,CISPI 301, CAST IRON CISPI 310 S.S. CLAMP & SHIELD CAST IRON SERVICE WEIGHT ASTM B16.1, B16.4, B16.12 W/ ASTM C564 RUBBER SEALING SLEEVE. HVY DUTY FOR SIZES >4". UNDER GROUND ASTM D1785, D2665 PVC ASTM F656 SOLVENT INSIDE BUILDING PVC SCHEDULE 40 ASTM D2466, D2467, WELD WITH ASTM D2564 F409 SOLVENT CEMENT ASTM A74, ASTM A888, CAST IRON CISPI 310 S.S. CLAMP & SHIELD CAST IRON CISPI 301 ASTM B16.1, B16.4, B16.12 W/ ASTM C564 RUBBER SEALING SERVICE WEIGHT SLEEVE. HVY DUTY FOR SIZES >4". GAS ASTM A53, GRADE B ANSI B16.3 INSIDE BLDG, BLACK STEEL TYPE E OR S. MALLEABLE IRON, THREADED SCHEDULE 40 CLASS 150 AIR ASTM B88 ANSI B16.18 CAST BRONZE ASTM B32 INSIDE BLDG COPPER TYPE L OR ANSI B16.22 WROUGHT GRADE 95TA SOLDER HARD DRAWN COPPER AND BRONZE VACUUM ASTM D1785, D2665 PVC ASTM F656 SOLVENT INSIDE BLDG PVC SCHEDULE 40 ASTM D2466, D2467, WELD WITH ASTM D2564 F409 SOLVENT CEMENT - WHERE MULTIPLE PIPE MATERIALS ARE LISTED, CONTRACTOR MAY CHOOSE FROM THOSE LISTED, UNLESS DRAWINGS SPECIFICALLY INDICATE PIPE MATERIAL (1) NO JOIINTS PERMITTED UNDERGROUND. INSULATION SCHEDULE SERVICE LOCATION INSULATION THICKNESS & TYPE INSULATION JACKET COLD WATER GENERAL BUILDING 1 2" RIGID F.G. OR CLOSED CELL 1 10 NR COLD WATER IN WALLS 1 2" CLOSED CELL 10 NR H.W. & H.W.R. ON RECIRC. LOOP GENERAL BUILDING 1" RIGID F.G. OR CLOSED CELL 10 NR H.W. BRANCH NOT ON RECIRC. LOOP GENERAL BUILDING 1 2" RIGID F.G. OR CLOSED CELL 10 NR I H.W. IN WALLS 1 2" CLOSED CELL NR NR = NOT REQUIRED INSULATION NOTES (1) INSULATE METERS, VALVES, BACKFLOW PREVENTERS AND ALL INLINE EQUIPMENT. (10) INSULATON NOT REQUIRED FOR EXPOSED FINAL PIPING CONNECTIONS TO FIXTURES. PLUMBING SPECIFICATIONS ENTERING THE PIPE. ALL PIPING SHALL BE FULLY CLEANED IN STRICT ACCORDANCE WITH INDUSTRY STANDARDS. I. BASIC PLUMBING REQUIREMENTS 5. PROTECT COPPER AND PLASTIC PIPE IN STUD WALLS WITH MINIMUM 1/16 SHIELD qi PLATES EXTENDING BEYOND THE PIPE IN ALL DIRECTIONS. A. SEE SHEET T2.0. 6. REVIEW CONNECTION REQUIREMENTS OF ACTUAL EQUIPMENT FURNISHED PRIOR TOQ B. SUBSTITUTIONS: WHERE SUBSTITUTE EQUIPMENT REQUIRES REDESIGN OF ANY PART OF THE ROUGH -IN. ADJUST ROUGH -IN TO MEET EQUIPMENT INSTALLATION REQUIREMENTS. PROJECT, THE COST OF REDESIGN AND ADDITIONAL COSTS OF THE WORK SHALL BE PAID BY 7. RUN ALL DRAIN LINES FROM EQUIPMENT OVERFLOW RECEIVERS, ETC. TO FLOOR / HUB THE CONTRACTOR. REDESIGN SHALL BE SUBJECT TO THE APPROVAL OF ALL AUTHORITIES DRAINS. DRAIN LINES SHALL BE HARD DRAWN COPPER INSTALLED WITH A MINIMUM OF 1/8 HAVING JURISDICTION OVER THE WORK INCLUDING THE ARCHITECT/ENGINEER. PER FOOT SLOPE. NO DRAIN LINE SHALL BE SMALLER THAN ?. INSTALL A TEE AT EACH C. PLUMBING CONTRACTOR SHALL VERIFY REQUIREMENTS FOR TEMPORARY WATER WITH ELBOW OF CONDENSATE DRAIN PIPING WITH A CLEANOUT PLUG ON THE BLIND TEE ExCEL GENERAL CONTRACTOR AND INCLUDE IN HIS SCOPE OF WORK WHEN DIRECTED BY G.C.. 8. INSTALL IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. EN G I N E E RI N G Inc. INSTALL IN ACCORDANCE WITH ALL CODE AND OSHA REQUIREMENTS FOR CONSTRUCTION 9. PROVIDE NON -CONDUCTING DIELECTRIC CONNECTIONS WHEREVER JOINTING DISSIMILAR PROJECTS. METALS. D. DETAILS AND SCHEDULES ARE SHOWN TO AID THE CONTRACTOR AND ARE NOT MEANT TO BE 10. PROVIDE CLEARANCE FOR INSTALLATION OF INSULATION AND ACCESS TO VALVES AND INCLUSIVE OF ALL DEVICES. PROVIDE REQUIRED EQUIPMENT AND ACCESSORIES FOR A FITTINGS. 100 CAMELOT DRIVE COMPLETE INSTALLATION. 11. SLOPE SANITARY PIPE 2" AND SMALLER 1/4" PER FOOT, 2-1/2" AND LARGER PIPING 1/8" PER FOND DU LAC, WI 54935 E. PROVIDE ALL STATE AND LOCAL PERMITS AND ANY OTHER RELATED FEES. FOOT. 9800 6 92- PHONE: (920) F. REGULATORY REQUIREMENTS 12. PIPING INSTALLED IN EXTERIOR WALLS SHALL BE INSTALLED ON THE ROOM SIDE OF FAX: (920) 20) 92 - 1. PROVIDE CERTIFICATE OF COMPLIANCE FROM AUTHORITY HAVING JURISDICTION EXTERIOR WALL INSULATON AND ONLY WHEN APPROVED BY THE ENGINEER. WHEREVER INDICATING APPROVAL BACKFLOW PREVENTION DEVICES INSTALLATION. POSSIBLE, AVOID ROUTING DOMESTIC WATER SUPPLY PIPING IN EXTERIOR WALLS. 2. PERFORM WORK PER ALL LOCAL AND STATE CODES, ORDINANCES AND REGULATIONS B. WATER PIPING TESTING AND BALANCING HAVING JURISDICTION. 1. TEST WATER DISTRIBUTION SYSTEM UNDER A WATER PRESSURE OF 100-PSI GAUGE WITH G. COORDINATE INSTALLATION OF PLUMBING WORK WITH THE OTHER CONTRACTORS AND THE POTABLE WATER FOR A PERIOD OF (4) HOURS. Always Aiwa Better Plan EXISTING BUILIDNG TO AVOID CONFLICTS WITH OTHER WORK. 2. FLUSH ALL NEW PIPING AND VERIFY THAT SUFFICIENT WATER FLOW, PRESSURE AND H. VERIFY CONNECTION REQUIREMENTS FOR EQUIPMENT FURNISHED BY OTHERS WITH FINAL TEMPERATURE ARE AVAILABLE AT EACH OUTLET AND EQUIPMENT CONNECTION. SHOP DRAWINGS. 3. BALANCE CIRCULATING HOT WATER SYSTEM TO INSURE PROPER CIRCULATION OF HOT 1. PROVIDE ALL CUTTING AND PATCHING NECESSARY FOR PLUMBING WORK INSTALLATION WATER IN THE SYSTEM WITH HOT WATER AVAILABLE TO ALL FIXTURES AND CONNECTIONS. UNLESS THIS WORK IS IDENTIFIED TO BE THE WORK OF OTHER CONTRACTORS. PATCHING C. DISINFECTION OF DOMESTIC WATER PIPING SYSTEM L() SHALL MATCH ADJACENT SURFACES. 1. FLUSH AND DISINFECT WATER SUPPLY SYSTEM IN ACCORDANCE WITH APPLICABLE STATE O J. P.C. SHALL PROVIDE SAWCUTTING, EXCAVATION, AND BACKFlLL OF EXISTING FLOORS AS PLUMBING CODE. M REQUIRED FOR INSTALLATION OF NEW UNDERGROUND PIPING. P.C. SHALL PROVIDE D. WATER SYSTEM VALVES CONCRETE IN REMOVED AREA OF THICKNESS TO MATCH EXISTING, AND WITH REINFORCING 1. MANUFACTURERS: NIBCO, APOLLO, HAMMOND, MILWAUKEE, KEYSTONE, CENTERLINE, Q PER FLOOR SLAB SPECIFICATIONS. PROVIDE DOWELS INTO EXISTING FLOOR SLAB. DOWEL DEZURIK, CRANE, MUELLER, POWELL. AND GRINNELL DIAMETER SHALL BE MINIMUM ONE EIGHTH OF FLOOR SLAB THICKNESS. DOWEL LENGTH SHALL 2. BALL VALVES 2" AND SMALLER: NIBCO MODEL S-585-70-NS, CHROME PLATED BRASS BALL, Z Y Y BE 12 FOR SLABS LESS THAN 6 THICK, 16 FOR SLABS 6-7 THICK, 18 FOR SLABS 8-9 THICK, TWO PIECE BRONZE BODY, FULL PORT, TEFLON SEATS AND STUFFING BOX RING, LEVER AND 20 FOR SLABS GREATER THAN 9 THICK. DOWELS SHALL BE SPACED 12 O.C. HANDLE WITH BALANCING STOPS AND VALVE STEM EXTENSIONS FOR INSULATED PIPING, Lv O:f 0 K. PROJECT COMPLETION SOLDER ENDS; 600 PSI WOG. :2 0- 1. CLEAN FIXTURES AND EQUIPMENT AND LEAVE IN PROPER WORKING CONDITION AT THE 3. BALANCE VALVES 2" AND SMALLER (MANUFACTURERS: NIBCO 1709/1710 SERIES, FLOWSET Ld TIME OF FINAL CLEAN-UP. ACCUSETTER, ARMSTRONG, AND TOUR AND ANDERSON): BRONZE BODY WITH CALIBRATED 0 > 2. REMOVE. CLEAN AND REPLACE AERATORS AFTER FLUSHING WATER PIPING. BRASS ORIFICE OR VENTURI, MEMORY STOP, SOLDERED ENDS AND PRESSURE TAPS. 125 Q 3. AS -BUILT DRAWINGS SHALL BE MARKED ON A FINAL SET OF DRAWINGS WHICH INCLUDES PSIG RATING AT 240 DEG F. Z W Li l ALL REVISIONS. 4. DRAIN VALVES: SHUTOFF VALVES WITH THREADED HOSE ADAPTER, CAP, AND CHAIN. Z PROVIDE FOR COMPLETE SYSTEM DRAINAGE, AND WHERE DETAILED. Q W II. FINISH AND PAINTING 5. SPRING LOADED CHECK VALVES 2" AND SMALLER: NIBCO MODEL 480, BRONZE BODY, TFE SEAT AND DISC, STAINLESS STEEL SPRING, THREADED ENDS, CLASS 125. Li A. COORDINATE WORK WITH THE PAINTERS SO THAT ALL EQUIPMENT IS INSTALLED PRIOR TO 6. INSTALL VALVE STEM BETWEEN THE VERTICAL (UPRIGHT) OR HORIZONTAL POSITION. J PAINTING. P.C. SHALL PAINT ITEMS IF NOT IN PLACE PRIOR TO NORMAL ROUTINE PAINTING. 7. DO NOT SUPPORT WEIGHT OF PIPING ON VALVE. B. IF FINISH BECOMES RUSTED, CORRODED, SCRATCHED, OR FLAKED DURING STORAGE OR Q INSTALLATION, REFINISH THE EQUIPMENT TO THE SATISFACTION OF THE OWNER. VIII. PLUMBING SPECIALTIES • • H U C. WHERE THE PLUMBING CONTRACTOR IS REQUIRED TO PAINT, THE PAINTING SHALL BE DONE IN Ld Q ACCORDANCE WITH THE PAINTING PORTION OF THE ARCHITECTURAL SPECIFICATION. A. PRESSURE GAUGES AND THERMOMETERS LL.I ry 1. MANUFACTURERS: H.O. TRERICE, U.S. GAUGE, ASHCROFT. MARSH, WEISS, AND WEKSLER. W 0 Z III. SUPPORTS AND ANCHORS 2. PRESSURE GAUGES: CAST ALUMINUM CASE, PHOSPHOR BRONZE BOURDON TUBE, Q GLYCERINE LIQUID FILLED, 4-1/2- DIAMETER, GAUGE COCK AND PULSATION DAMPER. 0-100 A. PIPE HANGERS AND SUPPORTS PSIG SCALE RANGE, 1 PSIG MINIMUM INCREMENT. Z v1 1. MANUFACTURERS: GRINNELL, B-LINE, MICHIGAN HANGER, UNI STRUT, AND PIPING 3. STEM THERMOMETERS: ASTM E1, RED APPEARING MERCURY, CAST ALUMINUM CASE WITH Ld TECHNOLOGY AND PRODUCTS. ENAMEL FINISH, CAST ALUMINUM ADJUSTABLE JOINT WITH POSITIVE LOCKING DEVICE, 9" 0- r cn 2. CONFORM TO ASME B31.9, MSS SP-58 AND MSS SP-69. SCALE, 3/4" NPT BRASS STEM, STEMS WITH EXTENSIONS AS REQUIRED FOR INSULATION. O o 00 Q 3. SUPPORTS IN DIRECT CONTACT WITH COPPER PIPING SHALL BE COPPER OR COPPER CLAD. 30-240 DEG. F SCALE RANGE, 2 DEG F MINIMUM INCREMENTS. Q (V Ld 4. PVC PIPE HANGERS AND SUPPORTS SHALL ALLOW FOR PIPE EXPANSION PER 4. EXTEND NIPPLES AND SYPHONS TO ALLOW INSULATION CLEARANCE. MANUFACTURER'S INSTALLATION INSTRUCTIONS. 5. INSTALL WHERE READ FROM NORMAL OPERATING LEVEL B. FIRE RATED INTERIOR WALL AND FLOOR PIPE PENETRATIONS 6. CALIBRATE FOR ACCURACY. 1. SEAL OPENING AROUND PIPE WITH A UL APPROVED FIRE -STOP SYSTEM HAVING AN F- B. WATER HAMMER ARRESTORS RATING NOT LESS THAN THE HOURLY RATING OF THE ASSEMBLY BEING PENETRATED 1. MANUFACTURERS: PRECISION PLUMBING PRODUCTS, SIOUX CHIEF, WATTS. (INSULATION FOR COLD PIPING SHALL BE CONTINUOUS THRU THE WALL AND FLOOR). 2. ANSI A112.26.1, SIZED 1N ACCORDANCE WITH PDI STANDARD WH-201. 2. WHERE UL FIRE -STOP SYSTEM REQUIRES A SLEEVE, FURNISH AND INSTALL SLEEVES FOR 3. INSTALL WITH ACCESSIBLE ISOLATION VALVE. NEW DRYWALL WALLS, AND CONCRETE WALLS AND FLOORS. FURNISH SLEEVES TO THE N MASON CONTRACTOR FOR INSTALLATION IN NEW MASONRY WALLS. PROVIDE SLEEVE AND IX PLUMBING FIXTURES GROUT SLEEVE IN EXISTING MASONRY WALLS. I 3. INSTALL CHROME PLATED STEEL ESCUTCHEONS AT PENETRATIONS EXPOSED IN FINISHED A. FIXTURES Q ROOMS. 1. LIKE FIXTURES SHALL BE THE PRODUCT OF THE SAME MANUFACTURER. 2. SAFETY COVERS OVER EXPOSED WASTE AND SUPPLY PIPING AT ADA ACCESSIBLE w IV. MECHANICAL IDENTIFICATION FIXTURES SHALL BE LAV-GUARD BY TRUEBRO OR EQUIVALENT. B. INSTALLATION A. NAMEPLATES 1. INSTALL IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. D 1. MANUFACTURERS: W.H. BRADY, AND SETON NAME PLATE COMPANY. 2. PROVIDE CHROME PLATED RIGID SUPPLIES TO FIXTURES WITH STOPS, REDUCERS, AND N 2. 3/4" HIGH, 1/16" THICK PLASTIC WITH ENGRAVED WHITE LETTERS ON BLACK BACKGROUND ESCUTCHEONS. COLOR, SCREW OR ADHESIVE MOUNTING. 3. SEAL FIXTURES TO WALL AND FLOOR SURFACES WITH MILDEW -RESISTANT SILICONE 3. PROVIDE AT CONTROL PANELS, STARTERS, MAJOR CONTROL COMPONENTS OUTSIDE SEALANT, COLOR TO MATCH FIXTURE. L,J Li! PANELS, AND WATER TREATMENT DEVICES. 4. REVIEW ARCHITECTURAL DRAWINGS FOR ELEVATIONS AND DIMENSIONED LOCATIONS OF :D B. VALVE TAGS PLUMBING FIXTURES. FIXTURES DESIGNATED FOR HANDICAP USE SHALL BE INSTALLED TO 1. MANUFACTURERS: W.H. BRADY, AND SETON NAME PLATE COMPANY. MEET THE MOST CURRENT APPLICABLE ADA GUIDELINES AND/OR ANSI REQUIREMENTS FOR Z Z 2. PLASTIC TAGS: 1-1/2" DIAMETER, 1/16" THICK LAMINATE PLASTIC WITH ENGRAVED LETTERS. CLEARANCE AND ACCESS. Ld Lit 3. TYPEWRITTEN LETTER SIZE CHART. 5. EXPOSED TRAPS, PIPING, AND ESCUTCHEONS SHALL BE CHROME PLATED BRASS. C) > 4. PROVIDE AT MAIN AND BRANCH PIPING VALVES. DRAIN VALVES DO NOT HAVE TO BE Q TAGGED. FIXTURE STOPS SHALL NOT BE TAGGED. Ld C. PIPE IDENTIFICATION X COMPRESSED AIR PIPING 0- 1. PROVIDE AT CONCEALED AND EXPOSED PIPING. IDENTIFY PIPE SERVICE AND FLOW AN.. PIPING INSTALLATION 7) --I J 2. REATECT OIDENi1FlCA110N NOT -TO -EXCEED 25 FEET FOR PIPING ABOVE CEILINGS. 1. DRAWINGS AND DIAGRAMS SHOW SIZE AND APPROXIMATE LOCATION OF PIPING. THE J (A Q � 3. LOCATE IDENTIFICATION NOT -TO -EXCEED 60 FEET FOR EXPOSED PIPING. MINIMUM ONE DRAWINGS ARE DIAGRAMMATIC AND SHALL NOT BE SCALED DETERMINE EXACT • • LOCATION. PROVIDE ADDITIONAL OFFSETS TO COORDINATE WITIT H INSTALLATION Q 0 LOCATION PER ROOM. H N N REQUIREMENTS OF OTHER SYSTEMS. ROUTE PIPING IN ORDERLY MANNER, PARALLEL TO J 4. LABEL PIPING DOWNSTREAM OF BACKFLOW PREVENTERS FOR INTENDED USE. Z J r 5. STENCILS: 2" HIGH LETTERS, SEMI -GLOSS ENAMEL BLACK PAINT. BUILDING STRUCTURE. OFFSET PIPE CONNECTIONS AT EQUIPMENT TO ALLOW FOR ! , Ljj -J M J 6. PIPE MARKERS SERVICE, SUCH AS REMOVAL OF THE EQUIPMENT. V a. MANUFACTURERS: W.H. BRADY, AND SETON NAMEPLATE COMPANY. 2. PREPARE EXPOSED UNFINISHED PIPE, FITTINGS, SUPPORTS, AND ACCESSORIES FOR W b. FLEXIBLE VINYL FILM TAPE WITH PRESSURE SENSITIVE ADHESIVE BACKING AND FINISH PAINTING. >- of PRINTED MARKINGS; SECURE WITH 2" WIDE TAPE WITH ARROWS INDICATING FLOW. 3. INSTALL IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. � Z }- I � 4. PROVIDE NON -CONDUCTING DIELECTRIC CONNECTIONS WHEREVER JOINTING DISSIMILAR Ld = = V. INSULATION METALS. O a- (1- 0 0- 5. PROVIDE CLEARANCE FOR ACCESS TO VALVES AND FITTINGS. 6. ALL TAKEOFFS SHALL BE FROM THE TOP OF THE PIPIING. v) LLJ I-, Li.l A. GENERAL 7. INSTALL VALVE STEM BETWEEN THE VERTICAL (UPRIGHT) OR HORIZONTAL POSITION. 1. INSULATION SYSTEMS SHALL MEET UL-723 REQUIREMENTS OF MAX. FIRE HAZARD B. DO NOT SUPPORT WEIGHT OF PIPING ON VALVE. I..L CLASSIFICATION OF 25, AND MAX. FLAME SPREAD, FUEL CONTRIBUTED, AND SMOKE B. UNIONS AND FLANGES DEVELOPED OF 50 WHEN INSTALLED IN RETURN AIR PLENUMS. 1. COPPER PIPE 2" AND SMALLER: BRONZE, SOLDERED JOINTS. 2. INSTALL MATERIALS IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS AND MICA C. VALVES SHEET ISSUE • PUBUCA11ON "COMMERCIAL AND INDUSTRIAL STANDARDS". 1999 FIFTH EDITION. 1. MANUFACTURERS: NIBCO, APOLLO, HAMMOND, MILWAUKEE, KEYSTONE, CENTERLINE, 3. INSULATE ENTIRE PIPING SYSTEM INCLUDING VALVES AND FITTINGS PER MICA INSULATION DEZURIK, CRANE, MUELLER, POWELL, AND GRINNELL STANDARDS PLATES 10 THRU 18. 2. BALL VALVES 2" AND SMALLER (MAIN PIPING): NIBCO MODEL T-585-70, CHROME PLATED 4. TAPER AND SEAL ALL INSULATION ENDS. BRASS BALL, TWO PIECE BRONZE BODY, FULL PORT, TEFLON SEATS AND STUFFING BOX NOVEMBER 23, 2009 5. CONTINUE INSULATION WITHOUT INTERRUPTIONS THROUGH WALLS, SLEEVES, AND RING, LEVER HANDLE, THREADED ENDS; 600 PSI WOG. HANGERS. 3. BALL VALVES 1" AND SMALLER (BRANCH PIPING TO EQUIPMENT): NIBCO MODEL T-585-70-SV, SEE TITLE SHEET TO CONFIRM B. FIBERGLASS (F.G.) INSULATION CHROME PLATED BRASS BALL, TWO PIECE BRONZE BODY, FULL PORT, TEFLON SEATS AND THAT THIS SHEET HAS BEEN 1. MANUFACTURERS: OWENS CORNING (O.C.) FIBERGLASS CORPORATION, CERTAINTEED, STUFFING BOX RING, LEVER HANDLE, THREADED ENDS, SAFETY VENT FOR PRESSURE RELEASED FOR CONSTRUCTION KNAUF, AND JOHNS MANVILLE. RELIEF OF DOWNSTREAM PIPING TO EQUIPMENT; 600 PSI WOG. 2. RIGID PIPING: 'K' VALUE 0.24, DOUBLE ADHESIVE SELF-SEALING LAP SYSTEM FOR REVISIONS: LONGITUDINAL JOINT, ALL SERVICE JACKET VAPOR BARRIER COVERING. INSULATION SHALL MEET ASTM E84 FLAME SPREAD SMOKE DEVELOPED INDEX OF 25/50. 3. VALVES, FITTINGS, AND FLANGE COVERS: HIGH IMPACT WHITE PVC, 0.02" THICK, WITH PRECUT FIBERGLASS INSERTS. C. CLOSED CELL INSULATION 1. MANUFACTURERS: ARMSTRONG, IMCOA, AND RUBATEX. 2. ELASTOMERIC MATERIAL, 'K' VALUE 0.27, 6 LB./CU. FT., MAXIMUM TEMPERATURE 180 DEG F. SYNTHETIC RUBBER BASE ADHESIVE WITH SYNTHETIC RESINS AND FILLERS. INSULATION SHALL MEET ASTM E84 FLAME SPREAD SMOKE DEVELOPED INDEX OF 25/50. VI. EXCAVATION AND BACKFlLL A. EXCAVATING 1. P.C. SHALL EXCAVATE AND BACKFlLL TRENCHES FOR PLUMBING WORK. 2. BRACE OR CRIB ALL EXCAVATGION AND PUMP ALL WATER WHERE REQUIRED TO PREVENT CAVING. 3. EXCAVATE MINIMUM 4" BELOW BOTTOM OF PIPE IF STONE GREATER THAN 1" IS ENCOUNTERED. 4. REMOVE UNSTABLE AREAS OF SUBGRADE BELOW PIPE TO MINIMUM 24" BELLOW PIPE. BACKFlLL WITH PEA GRAVEL, LIMESTONE SCREENINGS, OR EQUIVALENT AND COMPACT TO DENSITY EQUAL TO REQUIREMENTS FOR SUBSEQUENT BACKFlLL MATERIAL B. BACKFlLL AND COMPACTION SHALL MEET REQUIREMENTS SPECIFIED ELSEWHERE FOR AREA OF EXCAVATION. DATE: VIE. PIPING z NOV. 239 2009 A. PIPING INSTALLATION z JOB NUMBER 1. FIELD VERIFY EXISTING SEWER ELEVATIONS AND SIZES BEFORE BEGINNING BUILDING ROUGH -IN AND NOTIFY THE OWNER'S REPRESENTATIVE IN WRITING OF ANY VARIATION OF w 914790 THE ELEVATIONS BEFORE BEGINNING ANY SEWER AND BUILDING DRAIN WORK. Ld 2. DRAWINGS AND DIAGRAMS SHOW SIZE AND APPROXIMATE LOCATION OF PIPING. THE Z DRAWINGS ARE DIAGRAMMATIC AND SHALL NOT BE SCALED TO DETERMINE EXACT LOCATION. PROVIDE ADDITIONAL OFFSETS TO COORDINATE WITH INSTALLATION w SHEET REQUIREMENTS OF OTHER SYSTEMS. ROUTE PIPING IN ORDERLY MANNER, PARALLEL TO J BUILDING STRUCTURE. OFFSET PIPE CONNECTIONS AT EQUIPMENT TO ALLOW FOR ui U SERVICE, SUCH AS REMOVAL OF THE EQUIPMENT. 3. PREPARE EXPOSED UNFINISHED PIPE, FITTINGS, SUPPORTS, AND ACCESSORIES FOR w FINISH PAINTING. maim 4111111111h Q O 041 4. CAP ALL PIPE OPENINGS DURING CONSTRUCTION TO PREVENT FOREIGN MATTER FROM .P1 N y NORTH PARTIAL FLOOR PLAN -DEMOLITION X. CO T.G. NORTH DEMOLITION NOTES: — BOLD DASHED LINES INDICATE PIPING AND FIXTURES TO BE REMOVED. ALL ITEMS MAY NOT BE SHOWN. — ALL DEMOLITION BY GENERAL CONTRACTOR UNLESS NOTED OTHERWISE. SEE SHEET D1.1 FOR ADDITIONAL INFORMATION. — REMOVAL OF EXISTING FIXTURES, PIPING AND CAPPING OF PIPING BY G.C. — P.C. SHALL FIELD VERIFY EXISTING PIPE ROUTES AND SIZES AND COORDINATE WITH G.C. FOR PIPING P.C. DESIRES TO REUSE. — NO EXISTING PLANS OF PIPING EXIST. PIPING SHOWN IS ENGINEER'S ESTIMATION OF ROUTING. FIELD VERIFY LOCATIONS OF EXISTING PIPE MAINS. REUSE ANY PIPING OF SUFFICIENT SIZE IN GOOD CONDITION. REROUTE AS REQUIRED BY ACTUAL CONDITIONS. STRUCTURAL COORDINATION NOTES: — CLOSELY COORDINATE THE PLUMBING INSTALLATION WITH THE STRUCTURE, OTHER TRADES, AND CORRESPONDING OBSTRUCTIONS. SET INVERT ELEVATIONS OF ALL BRANCH LINES, LAYOUT EXACT RUNS, AND DETERMINE FINAL PITCH ADJUSTMENTS FOR UNDERFLOOR PIPING AS NECESSARY TO ACCOMMODATE FOUNDATION WALLS, PIERS, AND FOOTINGS. ADJUST PIPING AS NEEDED TO AVOID CONFLICT IN THE FIELD. CLOSELY COORDINATE ALL UNDERFLOOR PIPING LAYOUTS WITH THE GENERAL CONTRACTOR PRIOR TO CONSTRUCTION. VERIFY ALL PIPE ROUTING THROUGH OR BENEATH THE FOUNDATION WALLS WITH THE STRUCTURAL ENGINEER TO ENSURE PROPER PLACEMENT. DO NOT PIERCE, PENETRATE, OR OTHERWISE MODIFY ANY STRUCTURAL COMPONENTS WITHOUT PRIOR WRITTEN APPROVAL FROM THE STRUCTURAL ENGINEER. PARTIAL UNDERGROUND PLAN -DEMOLITION WATER WATER TO T. G. 100 CAMELOT DRIVE FOND DU LAC, VJI 54935 PHONE: (920) 926-9800 FAX: (920) 926-9801 Always a Better Plan I-- O � M Qr Z Y Y w Q O w w < Y Z Q w w w Z ry U Li Q V • • H z ry LLJ U Q W w o 0 z fj:� >- Z Z Q (/) cn W F— O Q T— V) N W N I Q w r � V) ry w w z w z w U > w Q n =) J J J H J J U w J M w o = ry = rv, z >- I 0- m o m ry 0 SHEET ISSUE: DATE: Z NOV. 239 2009 z JOB NUMBER: W 914790 W Z w SHFFT r f I� NORTH UNDERGROUND PLAN STRUCTURAL COORDINATION NOTES: - CLOSELY COORDINATE THE PLUMBING INSTALLATION WITH THE STRUCTURE, OTHER TRADES, AND CORRESPONDING OBSTRUCTIONS. SET INVERT ELEVATIONS OF ALL BRANCH LINES, LAYOUT EXACT RUNS, AND DETERMINE FINAL PITCH ADJUSTMENTS FOR UNDERFLOOR PIPING AS NECESSARY TO ACCOMMODATE FOUNDATION WALLS, PIERS, AND FOOTINGS. ADJUST PIPING AS NEEDED TO AVOID CONFLICT IN THE FIELD. CLOSELY COORDINATE ALL UNDERFLOOR PIPING LAYOUTS WITH THE GENERAL CONTRACTOR PRIOR TO CONSTRUCTION. VERIFY ALL PIPE ROUTING THROUGH OR BENEATH THE FOUNDATION WALLS WITH THE STRUCTURAL ENGINEER TO ENSURE PROPER PLACEMENT. DO NOT PIERCE, PENETRATE, OR OTHERWISE MODIFY ANY STRUCTURAL COMPONENTS WITHOUT PRIOR WRITTEN APPROVAL FROM THE STRUCTURAL ENGINEER. DENTAL EQUIPMENT COORDINATION: — PLUMBING CONTRACTOR TO VERIFY TYPE AND LOCATION OF ALL DENTAL EQUIPMENT, ROUGH —IN DIMENSIONS, AND REQUIRED PLUMBING CONNECTIONS. PLUMBING CONTRACTOR SHALL FURNISH AND INSTALL ALL FLOOR FIXTURES, FLOOR DRAINS, HUB DRAINS, WATER CLOSETS, LAVATORIES AND FLOOR SINKS. DENTAL EQUIPMENT SUPPLIER SHALL FURNISH AND INSTALL ALL FIXTURES IDENTIFIED ON THEIR PLANS (WITH THE EXCEPTION OF THOSE IDENTIFIED ABOVE). INSTALL ALL DENTAL EQUIPMENT AND PROVIDE ALL FIXTURE TRAPS, SUPPLIES AND STOPS, ISOLATION VALVES, MIXING VALVES, ETC. AND MAKE FINAL CONNECTIONS TO DENTAL EQUIPMENT. VERIFY ALL EQUIPMENT CONNECTIONS WITH THE TENANT AND EQUIPMENT SUPPLIER PRIOR TO INSTALLATION. PROVIDE ADDITIONAL CONNECTIONS AS REQUIRED. COORDINATE ALL WORK ACCORDINGLY. UNDERFLOOR PIPING NOTES: WATER — REFER TO UNDERGROUND LAYOUT DRAWING PROVIDED BY ASPEN DENTAL MANAGEMENT, INC. PRIOR TO ROUGH —IN OF FIXTURES. O1 ROUTE 2" UNDERFLOOR SANITARY UP TO LAVATORY (L-1). WATER O2 ROUTE 4" UNDERFLOOR SANITARY UP TO WATER CLOSET (WC-1). O3 ROUTE 3" UNDERFLOOR SANITARY UP TO FLOOR DRAIN (FD-1). TO ® ROUTE 2" UNDERFLOOR SANITARY UP TO TREATMENT SINK (S-1). T.G. SINK SHALL BE FURNISHED BY MILLWORK CONTRACTOR AND INSTALLED BY PLUMBING CONTRACTOR. 50 ROUTE 2" UNDERFLOOR SANITARY UP TO TREATMENT SINK (S-2). O ROUTE 2" UNDERFLOOR SANITARY UP TO STERILIZATION SINK (S-3). 70 ROUTE 2" UNDERFLOOR SANITARY UP TO LABORATORY SINK (S-4) WITH PLASTER TRAP. PLASTER TRAP ASSEMBLY FURNISHED BY SULLIVAN—SCHEIN AND INSTALLED BY THE PLUMBING CONTRACTOR ON THE SINK WASTE LINE. SEE DETAIL # D17/MD. ROUTE 2" UNDERFLOOR SANITARY UP TO BREAKROOM SINK (S-5). Q ROUTE 2" UNDERFLOOR SANITARY UP TO SERVICE SINK (SS-1). 10 ROUTE 3" UNDERFLOOR SANITARY UP TO A HEIGHT OF 18" FOR VACUUM WASTE. 11 PROVIDE UNDERFLOOR SANITARY WASTE CONNECTIONS TO THE EXISTING SANITARY SERVICE (PROVIDED BY LANDLORD). FIELD VERIFY EXISTING UNDERGROUND PIPING LOCATION, DEPTH AND SIZE AT POINT OF NEW CONNECTION PRIOR TO INSTALLATION OF ANY UNDERGROUND PIPING. 10 TRAP PRIMER PIPING. 10 ESTABLISH THE EXACT LOCATION AND SIZE OF UTILITY SERVICES PRIOR TO BUILDING ROUGH -IN. COORDINATE LOCATION OF BUILDING SERVICE ENTRANCES AND SYSTEM PIPE ROUTING WITH UTILITY SERVICE MAINS ON SITE AND ADJUST FOR SPECIFIC SITE FEATURES AND FIELD CONDITIONS ENCOUNTERED. 14 ROUTE 2" UNDERFLOOR SANITARY UP TO ELECTRIC WATER COOLER (EWC-1). EXCEL ENGINEERINGinc. 100 CAMELOT DRIVE FOND DU LAC, VA 54935 PHONE: (920) 926-9800 FAX: (920) 926-9801 Always a Better Plan Ln O Q Z Y ry w :2 ry Q 0 >_ W a_ a � Z Q w w W Z U Li J Q V) c/) D W Q LLJ W 0 0 Z Z Z a (n cn w l_ CL � V) O cn 00 a Q N w w H to w w H Z � Z W U w > Q W D J W W W < N • • Z (n J to J U w J M J 0 2 ry 2 ry Q_ 0— O 0— SHEET ISSUE: DATE: Z NOV. 239 2009 Z JOB NUMBER: w 91 A790 W Z w SHEET o P1.0 0 0 N NORTH I FLOOR PLAN SCALE: 1 /4" = 1'-0" COT.G. MECHANICAL ROOM DENTAL EQUIPMENT COORDINATION: - PLUMBING CONTRACTOR TO VERIFY TYPE AND LOCATION OF ALL DENTAL EQUIPMENT, ROUGH -IN DIMENSIONS, AND REQUIRED PLUMBING CONNECTIONS. PLUMBING CONTRACTOR SHALL FURNISH AND INSTALL ALL FLOOR FIXTURES, FLOOR DRAINS, HUB DRAINS, WATER CLOSETS, LAVATORIES AND FLOOR SINKS. DENTAL EQUIPMENT SUPPLIER SHALL FURNISH AND INSTALL ALL FIXTURES IDENTIFIED ON THEIR PLANS (WITH THE EXCEPTION OF THOSE IDENTIFIED ABOVE). INSTALL ALL DENTAL EQUIPMENT AND PROVIDE ALL FIXTURE TRAPS, SUPPLIES AND STOPS, ISOLATION VALVES, MIXING VALVES, ETC. AND MAKE FINAL CONNECTIONS TO DENTAL EQUIPMENT. VERIFY ALL EQUIPMENT CONNECTIONS WITH THE TENANT AND EQUIPMENT SUPPLIER PRIOR TO INSTALLATION. PROVIDE ADDITIONAL CONNECTIONS AS REQUIRED. COORDINATE ALL WORK ACCORDINGLY. FIRST FLOOR PIPING AND INSTALLATION NOTES: - PROVIDE ADDITIONAL BFP'S AS REQUIRED AT EQUIPMENT CONNECTIONS NOT SHOWN. FIELD VERIFY LOCATIONS AND REQUIREMENTS WITH EQUIPMENT CUT SHEETS. - REFER TO UNDERGROUND LAYOUT DRAWING PROVIDED BY ASPEN DENTAL MANAGEMENT, INC. PRIOR TO ROUGH -IN OF FIXTURES. 0 CONNECT NEW DOMESTIC WATER TO EXISTING DOMESTIC COLD WATER STUB AS PROVIDED BY LANDLORD. O2 FIELD VERIFY EXISTING WATER SERVICE ENTRANCE FOR EXISTING BACKFLOW PREVENTER. PROVIDE BFP-1 AS SHOWN IF NO BFP EXISTS. COORDINATE WITH ELECTRICAL CONTRACTOR TO MAINTAIN CODE REQUIRED CLEARANCES AROUND ELECTRICAL EQUIPMENT. O3 ROUTE 1 /2" CW AND HW PIPING DOWN IN CHASE FOR CONNECTION TO S-1. COORDINATE PIPE ROUTING THROUGH CHASE WITH MILLWORK MANUFACTURER'S TEMPLATE. O4 ROUTE 1/2" CW FROM COLD WATER STOP UNDER LAVATORY TO AUTOMATIC TRAP PRIMER (TP2) VALVE. ROUTE 1/2" CW FROM VALVE INTO WALL AND ROUTE UNDERFLOOR TO FLOOR DRAIN CONNECTIONS. SEE DETAIL 1 /P3.0. O PIPE 1/2" CW SUPPLY FROM SINK TO BFP-1 INSIDE CABINET BELOW SINK. PIPE IN WALL FROM BFP TO 44" A.F.F. FOR CONNECTION TO MODEL TRIMMER. TERMINATE WITH 3/8" COMPRESSION STOP. INSTALL IN ACCORDANCE WITH LOCAL CODES. SEE DETAILS D15/MD & 5/P3.0. © 1 /2" CW PIPING TO TRAP PRIMER (TP1). ROUTE 1 /2" CW PIPING DOWN WALL TO UNDERFLOOR. CONNECT PIPING UNDERFLOOR TO FLOOR DRAIN ASSEMBLY. SEE TRAP PRIMER DETAIL 2/P3.0. 0 EXTEND 3" VENT UP TO VTR. COORDINATE VTR LOCATION WITH MECHANICAL CONTRACTOR AND EXISTING EQUIPMENT SERVING ADJACENT TENANT SPACE. ADJUST VTR LOCATION AS REQUIRED TO MAINTAIN ALL CODE REQUIRED CLEARANCES. ® ROUTE 3" VENT UP FROM SANITARY HUB OUTLET SERVING VACUUM WASTE AND CONNECT TO VENT PIPING ABOVE CEILING. VENT SHALL SERVE AS BUILDING MAIN VENT. O9 SEE WATER HEATER DETAIL 4/P3.0. 10 2" HUB OUTLET INSIDE CABINET FOR BFP-1 DISCHARGE. ELIMINATE BFP AND H.O. IF PERMITTED BY AUTHORITY HAVING JURISDICTION. NOTES: - ALL PIPING IS TO BE CONCEALED. IF BUILDING CONSTRUCTION DOES NOT PERMIT CONCEALING PIPING, LOCATIONS AND ROUTING ARE TO BE APPROVED BY ARCHITECT/OWNER PRIOR TO INSTALLATION. 000 0 EXCEL ENGW EERINGiM. 100 CAMELOT DRIVE FOND DU LAC, WI 54935 PHONE: (920) 926-9800 FAX: (920) 926-9801 Always a Better Plan Lo O to V_ H Q Y Z w Y � O 12 W Q OL 0 Q Y Z Q w W W Z ry U w J Q 0 (n =) .. E— Z ry W U Q w O Z Z Q (/) co W F_ O (n 00 Q Q N W W H V) W W Z W Z w U r � Q °. __j J __j ILL. Q (n a 0 •• I'_ Z _j , J U W J M .J W = r � = rK a- O a - SHEET ISSUE: 7 IL q STACKED IN KNEE WALL. (TYP.) NORTH FLOOR PLAN - AIR AND VACUUM PIPING DENTAL EQUIPMENT COORDINATION: - PLUMBING CONTRACTOR TO VERIFY TYPE AND LOCATION OF ALL DENTAL EQUIPMENT, ROUGH —IN DIMENSIONS, AND REQUIRED PLUMBING CONNECTIONS. PLUMBING CONTRACTOR SHALL FURNISH AND INSTALL ALL FLOOR FIXTURES, FLOOR DRAINS, HUB DRAINS, WATER CLOSETS, LAVATORIES AND FLOOR SINKS. DENTAL EQUIPMENT SUPPLIER SHALL FURNISH AND INSTALL ALL FIXTURES IDENTIFIED ON THEIR PLANS (WITH THE EXCEPTION OF THOSE IDENTIFIED ABOVE). INSTALL ALL DENTAL EQUIPMENT AND PROVIDE ALL FIXTURE TRAPS, SUPPLIES AND STOPS, ISOLATION VALVES, MIXING VALVES, ETC. AND MAKE FINAL CONNECTIONS TO DENTAL EQUIPMENT. VERIFY ALL EQUIPMENT CONNECTIONS WITH THE TENANT AND EQUIPMENT SUPPLIER PRIOR TO INSTALLATION. PROVIDE ADDI1ONAL CONNECTIONS AS REQUIRED. COORDINATE ALL WORK ACCORDINGLY. GENERAL NOTES: — ALL VACUUM LINES SHALL BE INSTALLED BELOW SLAB UNLESS OTHERWISE NOTED. — TERMINATE COMPRESSED AIR LINES PER DENTAL EQUIPMENT DETAILS. — COMPRESSED AIR SHALL BE INSTALLED ABOVE CEILING UNLESS OTHERWISE NOTED. — VACUUM PIPING TO BE INSTALLED IN WALLS WHEREVER POSSIBLE. DROP OUT OF WALL AS NECESSARY AND EXTEND TO VACUUM MAIN AS INDICATED. — TERMINATION OF 1 1/2" VACUUM LINES TO BE REDUCED TO 1/2" FEMALE THREAD TYPICAL. FOR ALL UTILITY CENTERS, TERMINATION OF 1/2- AIR LINES TO BE 1/2- MALE THREAD WITH 3/8" COMPRESSION FITTING TYPICAL ALL PLUMBING AND ELECTRICAL FOR UTILITY CENTER SHALL BE CONTAINED WITHIN 8" X 14" AREA ON KNEEWALL. SEE DENTAL EQUIPMENT DRAWINGS FOR FURTHER INFORMATION. — REFER TO UNDERGROUND LAYOUT DRAWING PROVIDED BY ASPEN DENTAL MANAGEMENT, INC. PRIOR TO ROUGH —IN OF FIXTURES. O AIR COMPRESSOR TO BE FURNISHED AND INSTALLED BY THE OWNER'S EQUIPMENT PROVIDER. Q2 VACUUM SYSTEM TO BE FURNISHED AND INSTALLED BY THE OWNER'S EQUIPMENT PROVIDER. 0 ROUTE 1/2" COMPRESSED AIR LINE ABOVE CEILING AND TRANSITION TO HORIZONTAL FOR DISTRIBUTION. VERIFY LINE SIZE AND CAPACITY REQUIREMENTS WITH TENANT AND EQUIPMENT MANUFACTURER PRIOR TO INSTALLATION. ® ROUTE 1 1/2* VACUUM PIPING DOWN BELOW FLOOR FOR DISTRIBUTION. Q ROUTE VACUUM DISCHARGE TO ADJACENT 3" HUB DRAIN AS SHOWN ON SHEET P1.1. DISCHARGE IN ACCORDANCE WITH INTERNATIONAL PLUMBING CODE. Q ROUTE 2" PVC UP TO V.T.R. FROM VACUUM HEADS. TERMINATE ABOVE ROOF WITH GOOSENECK FITTING. CONNECTION BY PLUMBER. DO NOT JOIN WITH SANITARY VENT. MAINTAIN ALL CODE REQUIRED CLEARANCES ON THE ROOF. COORDINATE VTR LOCATIONS WITH MECHANICAL EQUIPMENT. 07 ROUTE 2" PVC UP TO ABOVE SUSPENDED CEILING FOR FRESH AIR INTAKE. DO NOT JOIN WITH SANITARY VENT. Q8 PROVIDE 1" DN IN WALL TO 50 LB LIQUID PETROLEUM CYLINDER AT EXTERIOR OF BUILDING. CONN. TO CYLINDER. CYLINDER BY P.C.. SEE ARCHITECTURAL PLANS FOR ADDITIONAL NOTES. 09 ROUTE NEW 1" GAS LINE DOWN IN WALL TO LAB WORK STATION AND PROVIDE 1/2" BRANCH LINES TO INDIVIDUAL LAB STATIONS. VERIFY ROUGH —IN LOCATION WITH TENANT REPRESENTATIVE. SEE LAB WORK STATION ELEVATION 3/P3.0. PROVIDE GAS PRESSURE REGULATOR AND EXTERIOR VENT IF REQUIRED PER OWNER FURNISHED EQUIPMENT (COORDINATE WITH OWNER AS REQUIRED). 10 PROVIDE 1/2" GAS LINE AND 1/2" AIR LINE STUBBED OUT AT LAB WORK STATION ELEVATION (SEE DETAIL 3/P3.0). PLUMBING CONTRACTOR TO MAKE FINAL CONNECTIONS. SEE SHEET P1.1 FOR ADDITIONAL GAS REQUIREMENTS. PROVIDE GAS SHUT—OFF ABOVE CEILING. 11 PROVIDE 1/2" COMPRESSED AIR CONNECTION AT 44" A.F.F. SEE DETAIL D13—A/MD FOR LABORATORY AIR VALVE AND D13/MD FOR STERILIZATION AIR VALVE DETAILS. 1© PROVIDE 1 1/2" VACUUM CONNECTION AND 1/2" COMPRESSED AIR CONNECTION TO UTILITY CENTER. STUB PIPING UP THROUGH WALL TO UTILITY CENTER ENCLOSURE AT 10" A.F.F. FOR TERMINATION BY OWNER'S EQUIPMENT PROVIDER. SEE DETAIL D-3/MD. 100 CAMELOT DRIVE FOND DU LAC, WI 54935 PHONE: (920) 926-9800 FAX: (920) 926-9801 Always a Better Plan I,,- O � M a � Z Y Y rY w :2 a O w 0 n < Z Y LLI w Z Q w U Li Q cn in ::) .. Z IY w U Q Ld W O 0 Z cy >_ Zzv) W O CL < r N V) W W I— D 0 W H W ZD Z W Z W U > Q W D J J Li J (A Q 0 ••< U w Jry (/) a. W O i� n W n Q N N SHEET ISSUE: NOVEMBER 23, 2009 SEE TITLE SHEET TO CONFIRM THAT THIS SHEET HAS BEEN RELEASED FOR CONSTRUCTION REVISIONS: r L-1 751M SEE UNDERGROUND PLAN AND FIXTURE UNIT SCHEDULE THIS SHEET FOR RUNOUT TRAP SIZE TO FIXTURE. �2 1/2" 2 1 /2" �I 2 1 /2" 10.5 2 1 /2" 17.5 I I I �� O2" O2" 3.5 4 I 2 1 /2" 10 �� H.O. " - T - EWC 1 7© EX. 3" VTR` 2 1 /2" 47. 1 1 /2" ( 2 1 /2" 4E ��` EX. 4"0 �1 1/2"� H.O. ��' I �� 2 1/2" 20 '�I • I �� 2 1 /2" I ,{�' Ell I 47.5 4" i� I I 22 4" ' V S500, II 1 1 /2"O2 SS ® 2 1 /2„ �� I FCO L-1 ©2 1/2 y �2"---'1 � � I � � I WC-1H = I PI LASTER V _RAP i ' �2 1/2" I I-�, 2"(:1) 5-2 I SS--3 ��� 0 2" --- � I I �' 4 ,S � �2" c` I(0000 3„O I I O2 1/2"� I FCO (``�4 WASTE AND VENT ISOMETRIC NO SCALE FIXTURE UNITS 4" 10 2" E11110vi NO. FIXTURE WASTE COLD WATER HOT WATER TOTAL WATER UNITS TOTAL TRAP I SIZE UNITS TOTAL BRANCH SIZE UNITS TOTAL BRANCH SIZE UNITS TOTAL 1 DRINKING FOUNTAIN EWC 0.5 0.5 1 1 4 0.25 0.25 1 2 - - - 0.25 0.25 3 FLOOR DRAIN- 3 5 15 3 - - - - - - - - 1 JHUB OUTLET- 2 3 3 2 - - - - - - - - 1 HUB OUTLET- 3" 5 5 3 - - - - - - - - 2 LAV 1 2 1 1 4 1.5 3 1 2 1.5 3 1 2" 2 4 8 SINK- S-1 & 2 2 16 1 1 2 1 8 1 2 1 8 1 2 1.5 12 2 SINK- S-3 & 4 2 4 1 1 2 3 6 1 2" 3 6 1 2 4 8 1 SINK- S-5 2 2 1 1 2" 1 1 1 2 1 1 1 2 1.4 1.4 1 SINK- SERVICE- 2 2 2 2 2.25 2.25 1 2 2.25 925 1 2 3 3 2 WATER CLO- TANK 4 8 - 5 10 1 2 - - - 5 10 3 TRAP PRIMER - - - 0.5 1.5 1 2 - - - 0.5 1.5 1 MODEL TRIMMER - - - 1 1 1 2 - - - 1 1 26 1 TOTAL 1 57.5 1 331 i 20.251 141.15 WATER CALCULATIONS WATER PRESSURE DATA 1 STATIC PRESSURE AT MAIN 55 PSIG 2 RESIDUAL PRESSURE AT MAIN 45 PSIG 3 RESIDUAL FLOW AT MAIN 1186 GPM 4 BUILDING FIXTURE UNITS 41.15 F.U. 5 PREDOMINATE FLUSH TYPE TANK 6 CONTINUOUS FLOW GPM 0 GPM 7 BUILDING DEMAND 24.4' GPM 8 RESIDUAL PRESSURE AT BUILDING DEMAND 55.0 PSIG 9 SAFETY FACTOR 5 PSIG 10 PRESSURE AVAILABLE FOR DOMESTIC USE 50.0 PSIG WATER SERVICE AND DISTRIBUTION SIZING DATA 11 ELEVATION OF RESIDUAL TEST HYDRANT 100.00 FEET 12 ELEVATION OF WATER METER 105.00 FEET 13 ELEVATION DIFFERENCE TEST HYDRANT TO METER 5.00 FEET 14 WATER METER SIZE 1 INCHES 15 DEVELOPED LENGTH MAIN TO METER 20 FEET 16 WATER SERVICE SIZE 1 INCHES PRESSURE AVAILABLE AFTER METER 15 PRESSURE DROP BETWEEN MAIN AND METER 16.20 PSIG/100' 16 FRICTION PRESSURE LOSS BETWEEN MAIN AND METER 3.2 PSIG 17 ELEVATION PRESSURE LOSS BETWEEN MAIN AND METER 2.2 PSIG 18 METER PRESSURE LOSS 2 PSIG 19 BACKFLOW PREVENTER PRESSURE LOSS 13 PSIG 20 PRESSURE AVAILABLE AFTER METER 29.6 PSIG WATER DISTRIBUTION SIZING - COLD WATER A PRESSURE AVAILABLE AFTER METER B START POINT TAG (SEE ISOMETRIC FOR TAG LOCATION) C DIST. PREVIOUS START POINT TO THIS START POINT D UNIFORM LOSS PREY. START POINT TO THIS START POINT E PIPE PRESSURE DROP FROM METER TO START POINT F CONTROLLING FIXTURE: ID: ROOM NAME & NO. PRESSURE REQUIRE[ G ELEV. DIFF. BETW. METER AND CONTROLLING FIXTURE H PRESSURE LOSS DUE TO WATER SOFTENER I PRESSURE LOSS DUE TO MIXING VALVE J PRESSURE AVAILABLE FOR PIPING PRESSURE DROP K DEVELOPED LENGTH START PT. TO CONTR. FIXTURE L EQUIVALENT LENGTH START PT. TO CONTR. FIXTURE M PRESSURE AVAILABLE FOR UNIFORM LOSS WATER DISTRIBUTION SIZING - HOT WATER A PRESSURE AVAILABLE AFTER METER B START POINT TAG (SEE ISOMETRIC FOR TAG LOCATION) C DIST. PREVIOUS START POINT TO THIS START POINT D UNIFORM LOSS PREY. START POINT TO THIS START POINT E PIPE PRESSURE DROP FROM METER TO START POINT F CONTROLLING FIXTURE: ID: ROOM NAME & NO.; PRESSURE REQUIREC G ELEV. DIFF. BETW. METER AND CONTROLLING FIXTURE H PRESSURE LOSS DUE TO WATER SOFTENER I PRESSURE LOSS DUE TO MIXING VALVE J PRESSURE AVAILABLE FOR PIPING PRESSURE DROP K DEVELOPED LENGTH START PT. TO CONTR. FIXTURE L EQUIVALENT LENGTH START PT. TO CONTR. FIXTURE M PRESSURE AVAILABLE FOR UNIFORM LOSS EX. 1" 41.1 TO EX. 1 " SEE WATER HEATER -.,,WATER METER PIPING DETAIL FOR CONTINUATION. 0.2 1 1/4- 1/2" 29.6 PSIG 100 CAMELOT DRIVE FOND DU LAC, WI 54935 PHONE: (920) 926-9800 FAX: (920) 926-9801 DI - Cement Lined PVC x Copper Always a Better Plan HDPE 150 Hazen Williams Coefficient 0.995 Pipe ID (� Lo O (SO Qr ~ Y Z Y � W j:jf O :2 Q >- LLI � C� of Y METER WSFU Copper Pipe Flush Flush WC-11-1 size tank valve MEN S 102 1 2 3.5 NP 8 PSIG 1 FEET 0 PSIG 0 PSIG 21.1 PSIG 155 FEET 233 FEET 9.1 PSIG 100' 3/4 13 NP 1 30 6.5 1 1 4 58 15 1 1 2 107 37 2 260 136 2 1 2 469 356 3 752 698 4 1792 1792 99.6 PSIG METER Pipe L-1 size WSFU Copper Rush tank 2 7 MEN S 102 1 2 8 PSIG 1 FEET 0 PSIG 8 PSIG 13.1 PSIG 245 FEET 368 FEET 3.6 PSIG 100' 3/4 1 16.5 1 1 4 33 1 1 2 66 2 225 2 1 2 469 752 1792 SEE FIXTURE UNIT SCHEDULE THIS SHEET FOR RUNOUT 18 PIPING SIZE TO FIXTURE. 185 ," CD 1 1 /4" 1" 12 17.5 1" TP-1 SS-1 F�-1 1.5 1/2" �� ���` � �� f 1" 14.5 3/4" 7 3/4" 7.5 -5 16 1 1 /4" ® 3/4" ' ® 3/4" TMV-1 5 3/4 12.5 1" TP-2 MODEL 4_i� `� -9 WC-1H 3/4" O7 3/„TRIMMER 5.5 FD-1 V- �2 ® 3/4„ \ 2 3/4" L-1 BFP-1•` S-4 ®3/4" I P-- 2 1H �- WC-O � � 11 F -1 EWC 1 5=2 S-3 ,, / WATER ISOMETRIC NO SCALE S2 N //; it I-EV4607 Z Q W L W Z U LLI • • f- Z 0:� W Q LJ W o 0 z 0. Z Z a U) cn W E-- LL- � U) 0V)00a Q N W N a W H D (/) IY W W Z Z W W U ] Q W J D J W ~ J J � U W J M LLI o = = OLd o 0-- a_ o- SHEET ISSUE: NOVEMBER 23, 2009 SEE TITLE SHEET TO CONFIRM THAT THIS SHEET HAS BEEN RELEASED FOR CONSTRUCTION REVISIONS: DATE: Z NOV. 23, 2009 z JOB NUMBER: W 914790 Z W SHFFT MpenD�fri�r�0 � P2.0 CHECK VALVE SHUT( VALVE 1 1 /4" CW THERMOMETER 1/2" IA-�HWR CP-1 I 1 1 /4" LLF -- -- -- HW i THERMOMETER 1 1 /4" T & P RELIEF VALVE i (PIPE TO 6" AFF OR FD) co I - z � ' TMvL1— LAIN II I WATER 1 " HEATER i I DRAIN REDUCER UNION VALVE WATER HEATER PIPING DETAIL NO SCALE MIN. 4" WALL OR OBSTRUCTION TEST COCKS- (TYP. OF 4) FLOOR LEVEL BACKFLOW PREVENTER - SUPPORT FROM WALL OR FLOOR STAND 12" MIN. TO 7'-0" MAX. MIN. 4" L OR - ,,--AIR GAP 1/2" GAS LINE REDUCED TO 3/8" FMT ON RT OF TABLE TERMINATE PER DETAIL D-13-3/MD. SHUTOFF 1/2" GAS LINE REDUCED TO " VALVE 6 3/8" FMT ON RT OF TABLE 6 UNION TERMINATE PER DETAIL D-13-3/MD. 3 7 1 /2" COPPER AIR LINE AT 24" AFF. TERMINATE PER DETAIL 0 o D-13A/MD.00 0 QUAD OUTLET BY E.C. (TYP.) 1/2" COPPER AIR LINE AT 24" lJ AFF. TERMINATE PER DETAIL D-13A/MD. 00 LAB WORK STATION ELEVATION SCALE: NONE MINIMUM 24" CLEAR IN FRONT, 4" CLEAR IN BACK, AND 18" CLEAR ABOVE BFP. PRESSURE GAUGE LABEL PIPING PER INTENDED USE. VLOCAL WASTE PIPE ® 1 /8" / FT. TO SITE DRAIN SAME SIZE AS LOCAL WASTE PIPE. LOCAL WASTE PIPE UNIT DRAIN SIZE 1 /2"-3/4"-1 " 1 1/2- 1 1 /4"-1 1/2" 2" 2"-2 1/2- 3" 3" 3" 4" AND LARGER 4" BACKFLOW PREVENTER DETAIL NO SCALE APPLIES TO REDUCED PRESSURE PRINCIPLE BFP, PRESSURE VB ASSEMBLY, AND BACK SIPHONAGE BACKFLOR VB. NOTE: DECK FLANGES OF THE PRE -MOLDED PIPE SEAL SHALL NOT BE OVERLAPPED, CUT OR APPLIED OVER ANY ANGLE CHANGE. PRE -MOLDED PIPE SEAL WITH INTACT RIB AT TOP EDGE. CUT-OFF MASTIC STAINLESS STEEL CLAMPING RING PRE -MOLDED PIPE SEAL EPDM MEMBRANE SPLICING CEMENT IN -SEAM SEALANT. LAP APPLY 1/2" FROM INSIDE EDGE OF PIPE SEAL SEALANT FLANGE. APPROX. 1/2" -I i- I I INSULATION ROOF DECK ROOF PIPE PENETRATION DETAIL NO SCALE EXTERIOR OF PIPE OR INSULATION (INSULATION CONTINUOUS THRU WALL OR FLOOR) CHROME PLATED S ESCUTCHEON PLAT BACKFLOW 1/2" CW CONNECTION (PROVIDE BACKFLOW PREVENTER AS REQUIRED BY CODE.) TRAP PRIMER-1 FLOOR PENETRATION L 1/2" TYPE "K" COPPER TUBING BENEATH SLAB TO FLOOR DRAIN OR HUB DRAIN ASSEMBLY. NO JOINTS BELOW FLOOR TRAP PRIMER DETAIL: SINGLE FLOOR DRAIN CONNECTIONS SCALE: NONE LOCAL WASTE PIPE LOCAL WASTE SIZE SHALL MATCH OUTLET SIZE OF ATMOSPHERIC PORT. SEE DETAIL D-16/MD FOR ADDITIONAL INFORMATION. INSTALL AS LOW AS AIR GAP POSSIBLE IN CABINET UNDER SINK. HUB OUTLET MODEL TRIMMER �ACKFLOW PREVENTER DETAIL 0 SCALE AL WOOL IACKING HARDENING EXTERIOR OF P OR INSULATION (INSULATION CONTINUOUS Ti WALL OR FL001 EXPOSED SIDE CONCEALED SIDE OF WALL IN OF WALL OR FINISHED ROOMS UNFINISHED ROOMS DRYWALL WALL CHROME PLATE ESCUTCHEON P MINERAL WOOL 'Q ^A. GALV. STEEL QR 1 PIPE SLEEVE EW MASONRY WALLS: IRNISH TO MASON. DNCRETE WALL: IRNISH AND INSTALL. MIN. 6" WHEN EXPOSED IN MECH. EQUIP. RM FLOOR -HARDENING _K LK AT FLOOR =TRATI ON _ OR FLOOR EXPOSED SIDE OF CONCEALED SIDE OF WALL WALL OR FLOOR IN OR FLOOR OR EXPOSED IN FINISHED ROOMS MECH. EQUIP. ROOM MASONRY OR CONCRETE WALL OR FLOOR NON -RATED INTERIOR PIPE PENETRATION DETAIL NO SCALE INSULATION AND SHIELDS PER DETAILS BELOW. r- PIPE CLAMP `-- STRUT SUPPORT SYSTEM TRAPEZE HANGER DETAIL HOT WATER STOP FLOOR - DRAIN-1 UNION LAVATORY (SINK) AUTOMATIC TRAP PRIMER-2 VALVE WITH BACKFLOW PREVENTION DEVICE PER CODE COLD WATER STOP TURN PRIMER DRAIN LINE INTO WALL TYPE "L" COPPER ABOVE FLOOR. KEEP MINIMAL TYPE "K" COPPER TUBING - NO JOINTS BELOW FLOOR TRAP PRIMER DETAIL SCALE: NONE MAX. SPACING BETWEEN PIPE SUPPORTS FFIPE SIZE STEEL AND COPPER PVC CAST IRON 1/2' 4 4' 5 3/4" 5' 4' 5' 1 " 6' 4' 5' 1 1 /4" 8' 4' 5' 1 1/2" 8' 4' 5' 2" 8' 4' 5' 2 1/2" 9' 4' 5' 3" 10' 4' 5' => 4" 12' 4' 5' MJJ = MAIVUrAU IUNLK J J IANUAKUILA IIUN JUCUIL I T THREADED MILD STEEL BLACK OR ZINC PLATED FINISH. COPPER PLATED WHEN IN CONTACT WITH COPPER PIPE. (TYP.) CARBON STEEL ADJUSTABLE SWIVEL RING (MSS SP-69 TYPE 10) OR ADJUSTABLE CLEVIS (MSS SP-69 TYPE 1). (TYP.) INSULATION (THICKNESS AND TYPE PER SCHEDULE) (TYP.) GALVANIZED CARBON — STEEL INSULATION PROTECTION SHIELD (MSS69 TYPE 40) OR WOOD BLOCK SUPPORT. HANG FROM BEAM CLAMPS, CONCRETE INSERTS, UNI-STRUT, STRUCTURAL STEEL OR WALL BRACKET. (TYP-) TYPICAL OF HANGER AT LEFT. APPLICATIONS: APPLICATIONS: - UNINSULATED PIPING - HOT & COLD PIPING 2 1/2" AND SMALLER. PIPE HANGER AND INSULATION DETAILS NO SCALE tLA/11 100 CAMELOT DRIVE FOND DU LAC, WI 54935 PHONE: (920) 926-9800 FAX: (920) 926-9801 Always a Better Plan O Q H Z Y � � Ld 12 Q O i- Ld 0- � Q Z Y Ld Ld Z Q LLI U w ___I < V) V) Z w Q Woz>- Ld 0 ry Z Z Q (/'1 V) W � OQNLd CL 'r- V) N I Q Ld H N LrL.I Li.l Z Z Ld Lj U > of Q Ld 0- J D J LL_ J • • I— Z _J J U w __J M __J w0Ld a- IZ O o- (n Li! I-, LLi Q SHEET ISSUE: NOVEMBER 23, 2009 SEE TITLE SHEET TO CONFIRM THAT THIS SHEET HAS BEEN RELEASED FOR CONSTRUCTION REVISIONS: DATE: z Nnv_ .,;;_ gnnq z JOB NUMBER: W w 914790 w z W SHFFT J W U X w o P3.0 SINK SCHEDULE (S.) SINK FAUCET NO. COMPARTMENT OVERALL SIZE MODEL NO. HOLES SPOUT HANDLE FINISH SPRAY MODEL NO. DEPTH REACH HEIGHT 1 1 1 1 1 1 1 1 (1 1 1 1 2 1 7" 22" x 19.5" ELKAY PSR-2219 3 9.5" 8.25" SINGLE CHROME YES DELTA 172-SSWF 2 3 1 7.5" 33" x 19.5" ELKAY LR-3319 3 9.5" 8.25" SINGLE CHROME YES DELTA 172-SSWF (2) 4 1 7.5" 33" x 19.5" ELKAY LR-3319 3 9.5" 8.25" SINGLE CHROME YES DELTA 172-SSWF 2 3 5 1 7" 22" x 19.5" ELKAY PSR-2219 3 9.5" 8.25" SINGLE CHROME YES DELTA 172-SSWF 2 - ACCEPTABLE MANUFACTURERS: -STOPS AND SUPPLIES: KOHLER, BRASSCRAFT, DEARBORN, KEENEY, MCGUIRE. -DRAINS AND TRAPS: KOHLER, DEARBORN, KEENEY, MCGUIRE, BRASSCRAFT. - SELF -RIMMING 20 GA. 302 S.S. SINK, ANGLE SUPPLIES WITH HANDLE STOPS (BRASSCRAFT OR1512DLZ C). PROVIDE EACH COMPARTMENT WITH STAINLESS STEEL STRAINER AND TAILPIECE (ELKAY LK-35B), AND 1-1/2" "P" TRAP (BRASSCRAFT 0030). - VERIFY SINK CUTOUT SIZE WILL FIT IN COUNTERTOP WITH CABINET SHOP DRAWINGS PRIOR TO ORDERING. (1) FURNISHED BY MILLWORK CONTRACTOR, INSTALLED BY P.C. (2) ALTERNATE FAUCET: MOEN 7750 WITH HAND SPRAY. (3) INSTALL PLASTER TRAP FURNISHED BY SULLIVAN- SCHEIN. THERMOSTATIC MIXING VALVE SCHEDULE (T.M.V.) NO. SERVICE INLETS OUTLET ACT. P.D. PSI MAX. FLOW GPM ACTUAL FLOW GPM MODEL REMARKS 1 WATER HEATER 1" 1" 8 23.0 8 1170 "WATTS" 2 1 LAVATORY 1 3/8" 1 3 8" 25 4.0 1.5 USG-B "WATTS" 4 - ACCEPTABLE MANUFACTURERS: SYMMONS, WATTS, POWERS, ZURN. - PROVIDE WITH CHECK STOPS, REMOVABLE CARTRIDGE WITH STRAINER, STAINLESS STEEL PISTON, AND SOLID WAX HYDRAULIC PRINCIPLE THERMOSTAT. TRAP PRIMER SCHEDULE (T.P.) NO. LOCATION CONN. SIZE MODEL REMARKS 1 MECH. 1 2" P2-500 "PRECISION PLUMBING PRODUCTS" 2 TOILET 1 /2" PR-500 "PRECISION PLUMBING PRODUCTS" WATER CLOSET SCHEDULE (W.C.) NO. M rG FLUSH TYPE BOWL FLUSH VALVE TYPE FLUSH VALVE SUPPLY STOP MFR ODEL SEAT MFR ODEL RIM HT. A.F.F. PIPING CONNECTION 1H FLOOR TANK AM. STD. 2998.012 16-1 2" HANDLE STOP - BRASSCRAFT HR1512DLZ-C CHURCH 9400C - ACCEPTABLE MANUFACTURERS: -SUPPLY STOPS: BRASSCRAFT, CHICAGO, KOHLER, DEARBORN, KEENEY, MCGUIRE. - WATER SAVING 1.6 GPF, SIPHON JET ELONGATED VITREOUS CHINA WATER CLOSET BOWL WITH WHITE SOLID PLASTIC OPEN FRONT SEAT WITH SELF-SUSTAINING CHECK HINGE. - TANK WATER CLOSETS: CLOSE -COUPLED WITH VITREOUS CHINA TANK AND COVER, FLUSH ASSEMBLY, ANGLE SUPPLY, AND TANK INSULINER. - FLOOR SET WATER CLOSETS WITH BOLT CAPS. - CONTROLS FOR ADA ACCESSIBLE FIXTURES SHALL BE ON THE OPEN SIDE. CLEANOUT SCHEDULE SYM. LOCATION SIZES BODY MAIL PLUG MAIL ACCESS COVER MISC. FIGURE REMARKS MA L MISC. CO ABV. CLGS & EXPOSED PIPE 2" - 6" C.I. PVC - - - Z-1440 "ZURN" FCO FINISHED ROOMS W/O CARPET 1 2" - 6" C.I. PVC N.B. - - Z-1400 "ZURN" FCO FINISHED ROOMS WITH CARPET 1 2" - 6" C.I. PVC N.B. CARPET MARKER - Z-1400-CM "ZURN" WCO WALL 2" - 6" C.I. PVC S.S. - - Z-1446 "ZURN" - RECESSED TAPER THREAD PLUG WITH SLOTTED RECESS. (1) FINISHED ROOMS ARE ROOMS WITH CARPET OR FLOOR TILE OR ROOMS ACCESSIBLE BY A DOOR LESS THAN 42" WIDE. DRAIN SCHEDULE SYM. TYPE APPLICATION OUTLET SIZE BODY MAT'L STRAINER TOP MISC. MODEL REMARKS MA L SIZE FD-1 FLOOR PEDESTRIAN TRAFFIC 2"-3" (1) CAST IRON N. B. "TYPE S" 5" DIA TRAP PRIMER CONN. N-415-S-DP- "ZURN" (2 H.O. HUB OUTLET INDIRECT WASTE 1 - - - STUB 2" A.F.F. - - (1) AS NOTED ON DRAWINGS (2) DECORATIVE POLISHED TOP NOT REQUIRED IN MECHANICAL ROOM. BACKFLOW PREVENTER / VACUUM BREAKER SCHEDULE (B.F.P.) MAX. MAX. BFP/VB ASSE SYM. LOC. GPM P.D. SIZE TYPE HAZ. PRESS. APPLICATION STD. MODEL REMARKS PSI BFP-1 LAB 2.0 4.0 1/2" BFP W/ INT. LOW CONTIN. MODEL TRIMMER 1012 9D (1) "WATTS" ATM. VENT BFP-2 I MECH 24.0 13.0 1 1 /4" REDUCED PRESS. HIGH CONTIN. WATER SERVICE 1013 009 "WATTS" 1 PRINCIPLE BFP - ACCEPTABLE MANUFACTURERS: WATTS, CONBRACO, AMES. (1) P.C. SHALL VERIFY SCHEDULED BFP IS ADEQUATE FOR HAZARD LEVEL WITH PLUMBING INSPECTOR. USE SCHEDULED BFP UNLESS PLUMBING INSPECTOR CLASSIFIES AS HIGHER HAZARD. P.C. SHALL INSTALL BFP IN ACCORDANCE WITH MANUFACTURERS RECOMMENDATIONS AND CODE CLEARANCE REQUIREMENTS. RELOCATE/REROUTE AS REQUIRED IF LOCATION SHOWN ON PLAN DOES NOT MEET REQUIREMENTS. PROVIDE ALL NECESSARY DRAIN PIPING, ETC. FOR A COMPLETE INSTALLATION. ELECTRICAL/STARTER/DISCONNECT SCHEDULE SYM. LOCATION ELECTRICAL DATA STARTER DISCONNECT REMARKS HP KW AMPS VOLT PH. TYPE LOCATION FURN. BY ACCESS- ORIES DIS- CONNECT FURN. BY EWC-1 SEE DWG - - 4.0 120 1 INTEG INTEGRAL EM - NR - REC. WH-1 MECH. - 2 04.51 - 1 208 3 INTEG INTEGRAL EM - R EC H.W. 1 CP-1 MECH. - 0.04 - 120 1 RELAY MECH RM PC - NR - - STARTER TYPE: INTEG.= INTEGRAL: PROVIDED INTEGRAL WITH EQUIPMENT. RELAY= UL LISTED MOTOR RATED RELAY WITH SEPARATE ENTRANCES FOR INPUT AND OUTPUT CONTACTS, AND LED STATUS INDICATOR. FURNISHED BY: EM = EQUIPMENT MANUFACTURER PC = HEATING CONTRACTOR EC = ELECTRICAL CONTRACTOR ACCESSORIES: HOA = HAND -OFF -AUTO PL = PILOT LIGHT PB = PUSH BUTTON 2-SP = TWO SPEED RV = REDUCED VOLTAGE - ACCEPTABLE MANUFACTURERS: ALLEN BRADLEY, CUTLER HAMMER, SQUARE D, GENERAL ELECTRIC. - VERIFY VOLTAGE AND PHASE WITH ELECTRICAL CONTRACTOR BEFORE ORDERING EQUIPMENT. (1) ELEMENTS WIRED FOR SIMULTANEOUS OPERATION. UNBALANCED LOAD. DISCONNECT: NR= NOT REQUIRED R = REQUIRED WP= WEATHERPROOF F= FU SED REMARKS: H.W.= HARD WIRED REC.=RECEPTACLE ELECTRIC WATER COOLER SCHEDULE (E. W. C. ) NO. RECESS CAP. (GPH) BARRIER FREE NUMBER OF BASINS CONTROL RATED WATTS FULL LOAD AMPS MODEL REMARKS 1 NO 8.0 YES 2 FRONT PUSHBAR 370 4.0 EZTL-8-C "ELKAY" 1 - ACCEPTABLE MANUFACTURERS: ELKAY, HALSEY TAYLOR, OASIS, HAWS, FILTRINE. - PROVIDE WITH 1-1/4" WITH C.O. PLUG ("BRASSCRAFT" 0010BX), AND ANGLE WATER STOP WITH HANDLE ("BRASSCRAFT" OCR19Z C). - CAPACITY BASED ON 50 DEGREE F WATER IN AMBIENT TEMPERATURE OF 90 DEGREES F. (1) FULLY EXPOSED, STAINLESS STEEL BASIN, STAINLESS STEEL PANEL. WATER HEATER SCHEDULE (W.H.) NO. LOC. TYPE MOUNTING SIZE DIA. X HT. COMM. TANK WARR. KW VOLTAGE PHASE AMPS REC. GPH TANK SIZE GAL. MODEL REMARKS 1 MECH COMM. FLOOR 20" x 46" 3 YR 4.5 4.5 (1) 208/3 37.5 21.6 2 37.0 40 DEN-40 "A.O. SMITH" - RECOVERY BASED ON 100 DEGREE F TEMPERATURE RISE, GLASS LINING, 100 PSIG T&P RELIEF VALVE SETTING, 150 PSIG WORKING PRESSURE. (1) ELEMENTS WIRED FOR SIMULTANEOUS OPERATION. (2) UNBALANCED LOAD. CIRCULATING PUMP SCHEDULE (C.P.) NO. SERVICE FLUID TEMP F GPM HEAD (FT) RPM MOTOR H.P. MIN. EFF. TYPE MODEL REMARKS 1 HOT WATER CIRC 120 3 5 2800 39 WATT - IN -LINE NBF-8 "B & G" (1 (1) PROVIDE "INTERMATIC" MODEL SS7C DIGITAL 7-DAY SWITCH TIMER TO CONTROL PUMP OPERATION. EXPANSION TANK SCHEDULE (E.T.) NO. MOUNTING TANK TYPE CONN. SIZE TANK CAP. GAL. ACCEPT. CAPACITY GAL. PRECHARGE PRESSURE PSIG WORKING PRESS PSIG DIA. HEIGHT WEIGHT FILLED LBS. MODEL REMARKS 1 PIPE DIAPHRAGM 3 4" 2.1 1.0 55 150 9" 12" 16 WH 8 "FLEXCON" LAVATORY SCHEDULE (L.) NO. MOUNTING OVERALL SIZE FAUCET CENTERS LAV MODEL DRAIN 2 SUPPLY STOP FAUCET TYPE MODEL TYPE MODEL TYPE MODEL 1 WALL HUNG 21" x 18" 4" AM. STD. 0124.024 1) OFFSET K-13885 HANDLE BRASSCRAFT HR1512AZ C WRIST BLADE AM. STD. 7400.172V.V15 - ACCEPTABLE MANUFACTURERS: -DRAINS AND TRAPS: KOHLER, DEARBORN, KEENEY, MCGUIRE, BRASSCRAFT. -STOPS AND SUPPLIES: KOHLER, BRASSCRAFT, DEARBORN, KEENEY, MCGUIRE. -CARRIERS AND SUPPORTS: ANCON, JOSAM, SMITH, WADE, ZURN. - ALL MODEL NUMBERS BASED ON KOHLER UNLESS INDICATED OTHERWISE. - VITREOUS CHINA LAVS, 1-1/4" "P" TRAP WITH CLEANOUT PLUG (BRASSCRAFT 0010), BUSHING ON END OF OUTLET TUBE, WALL FLANGE. - WALL HUNG LAVS WITH BACKSPLASH. - FAUCETS WITH VANDAL RESISTANT AERATOR. (1) MOUNT TOP OF RIM AT 34" A.F.F. (2) PROVIDE TRUEBRO MODEL #102 INSULATION KIT. SERVICE SINK SCHEDULE (S.S.) NO. MOUNTING BASIN FAUCET MA L SIZE RIM GUARD MODEL PIPING EXPOSURE BACKFLOW PREVENTER MFR ODEL 1 WALL DURASTONE 23x25x34 - MUSTEE 14C DECK MOUNT WATTS SERIES 8 (1) (1) FAUCET, SUPPLY HOSES AND P-TRAP FURNISHED WITH BASIN BY MANUFACTURER. 100 CAMELOT DRIVE FOND DU LAC, WI 54935 PHONE: (920) 926-9800 FAX: (920) 926-9801 Always a Better Plan L7 O M Qr Z Y � W � a 0 � w 0- < Z Y w w Z Q w U Li J a cn � ::D Z W Q Ld Z Z z a cn cn w I-- O < N (n W N I Q W V) W W Z W Z W U > W Q W ::D J _1 ILL. ZJ J U W J M J Ld o = = OLd IL a_ O (1- 0 W I� W CL Q N � N SHEET ISSUE: DATE: Z NOV. 23, 2009 z JOB NUMBER: Li Li914790 w z 0 W -qHFFT a P44PO AUpen[Da= J6