Loading...
HomeMy WebLinkAboutGall Blvd - Zephyr Commons BldgREVISION DESCRIPTION Date: September 27, 2022 Issued By: Justin King, Project Captain RE. ZEPHYR COMMONS APARTMENTS FORUM PROJECT 4097 PERMIT NUMBER #### REVISION INFORMATION Title: VE & Coordination Number: # 1 Date: September, 21 2022 FORunn■ (Z, e:> cy 19(¢'�? -- A list of revised drawings, including narrative descriptions of the changes to those drawings, is provided below. This list is provided as a convenience and does not supersede a thorough review of the revised drawings. Please insert revised sheets into your set. The attached signed/sealed drawings are for resubmittal to Building Department. Please contact us at your convenience with any questions. A1.01-I, A1.01-II • List all revised drawings • Added new sheets — clouded on sheet • Include a narrative description of the changes made to each sheet A1.04 • Added wood wall assembly WW-25 per owner request • Revised WW-53 to conform to stair • Removed masonry assembly WC-10 • Removed light gauge steel assemblies WS-14, WS-15 A1.05 • Added wood floor assembly FW-10 per owner request A1.11, A1.21 • Removed DAS room A2.01 • Updated CH construction type S3.11, S3.12, S3.13, S3.14, S3.15, S3.21, S3.22, S3.23, S3.24, S3.25 • Revised stair plans S4.04.2 • Revised shearwall schedule. ZZQZ 6 � AON G A1W1:%?�� i P:\NADG\ZEPHYRCOMMONSAPTS.4097\ADMIN\REVISION DESCRIPTIONS\REVISION DESCRIPTION - REV 1.DOCX FORUM ARCHITECTURE & INTERIOR DESIGN, INC. 237 S Westmonte Dr, Suite 220, Altamonte Springs, FL 32714 0 P(407) 830-1400, F(407) 8304143, AA0002731 ■ www.forumarchitecture.com S4.12, S4.13, S4.22 • Revised stair details A5.10, A5.20 • Revised slab dimensions to accommodate revised stair walls A5.11 • Removed C1 unit railing at patio • Revised framing dimensions to accommodate revised stair walls • Added Fire extinguishers to corridors and removed from units • Removed DAS room A5.12 • Revised framing dimensions to accommodate revised stair walls • Added Fire extinguishers to corridors and removed from units • Removed DAS room A5.13, A5.23 • Revised roof calculations • Revised off -ridge vents on roof plan • Revised low roof at stairs A5.21, A5.22 • Revised framing dimensions to accommodate revised stair walls • Added Fire extinguishers to corridors and removed from units • Removed DAS room A5.61 a, A5.62, A5.63, A5.64, A5.65a, A5.67a & A5.68 • Removed Fire extinguishers in units. • Revised Fridge in B units A5.61 b, A5.65b & A5.67b • Revised Fridge in B units A5.66 • Removed Fire extinguishers in units. • Add minimum dimension at vanity sink in bathroom A5.69 • Removed Fire extinguishers in units. • Revised Fridge in B units • Add minimum dimension at vanity sink in bathroom A5.81 • LVT to Carpet in bedrooms & closets • Added transition details from carpet to Ivt. #6 • Removed DAS closet from enlarged plans • Added tub/shower detail at adjacent walls. #7 P:\NADG\ZEPHYRCOMMONSAPTS.4097\ADMINIREVISION DESCRIPTIONS\REVISION DESCRIPTION - REV 1,DOCX FORUM ARCHITECTURE & INTERIOR DESIGN, INC. 237 S Westmonte Or, Suite 220, Altamonte Springs, FL 32714 ■ P(407) 830-1400, F(407) 830-4143, AA0002731 ■ www.forumarchitecture.com A6.11 • Revised stone veneer on elevations per owner request • Revised low roof at stairs A6.21 • Removed the rail on side elevation at rear. • Revised stone veneer on elevations per owner request • Revised low roof at stairs A6.61 • Revised stone veneer on elevations per owner request A7.01 & A7.02 • Revised stair wall call -outs A7.13 • New Stair wall detail sections A7.23 • Removed CMU detail sheet from set A8.11 • Revised Enlarged Plans & Sections • Revised low roof at stairs A8.12 • Revised Stair Details from metal to wood A9.11 • Revised door height from 7'-0" to 6'-8" per owner request • Revised remarks for mech door in units • Removed CMU details - #3, #4 • Removed DAS doors • Revised Unit Entry door frame from metal to wood • Removed remark 10 from door 113 and 213 A9.21 • Removed CMU details - #10, #11, #12 A17.01 — Clubhouse • List all revised drawings A17.11 — Clubhouse • Revised calc table • Revised breakroom background A17.20, A17.21 — Clubhouse • Revised breakroom background P:\NADG\ZEPHYRCOMMONSAPTS,4097\ADMIN\REVISION DESCRIPTIONS\REVISION DESCRIPTION - REV 1 DOCX FORUM ARCHITECTURE & INTERIOR DESIGN, INC. 237 S Westmonte or, Suite 220, Altamonte Springs, FL 32714 ■ P(407) 830-1400, F(407) 830-4143, AA0002731 ■ www.forumarchiter-ture.com A17.22 — Clubhouse • Revised breakroom background • Added missing elevation tag in Clubroom • Added keynote 38 A17.23 - Clubhouse • Revised roof calculations • Revised off -ridge vents on roof plan A17.26 - Clubhouse • Revised title to correctly show name E18.11 -Clubhouse • Relocated sink and deleted the floor sink in the Break room E18.12 - Clubhouse • Relocated sink and ice maker box in the break room. Indicated ice maker box at the coffee maker E18.31 -Clubhouse • Revised breakroom counter receptacle layout to coordinate with architectural changes A19.01 — Pool Pavilion • Updated Title Sheet A19.21 — Pool Pavilion • Revised Counter to coordinate with ID A20.01 — Trash & Maintenance • Updated Title Sheet A20.21 — Trash & Maintenance • Added downspouts to bldg This concludes our revision description. Sincerely, FORUM ARCHITECTURE & INTERIOR DESIGN, INC. P:\NADG'',.ZEPHYRCOMMONSAPTS.4097\ADMIN+.REVISION DESCRIPTION S\REVISION DESCRIPTION - REV 1.DOCX FORUM ARCHITECTURE & INTERIOR DESIGN, INC. 237 S Westmonte or, Suite 220, Altamonte Springs, FL 32714 ■ P(407) 830-1400, F(407) 830-4143, AA0002731 ■ www.forumarchitecture.com A lk