HomeMy WebLinkAbout38965 CR 54Notes and Specifications Building Erection Notes 1) The general contractor and/a erector is responsible to sofay and properly erect the meld building system in conformance with these drasings. OSHA roqubomente and metal building system In canfomnornce with these drartnga. OSHA mWimmente and either NON or CSA SIG standards pertaining to proper arsctlar. This Includes. but I. net lured to, the correct ues of terrpoary guys and bracing whom needed for squaring, plumbing and securing the structural and secondary framing. Soocedory wag (mrinqq momben (girt■ or bar )dab) ore not dedgmed to function are o ■ark platform or prorM. solely W-off attachment In otcondoms with OSHA ngWrsmsult. Secondary roof fron " members (Pudlne a bar jdete) are not dsigned Is prw,ids *$fay Us -all attachment in accordance with OSHA requirements. 2) A325 & A499 Bait tighlarinq requirements. It to the respandWlly of tfre erector to soup proper boll Ughtne*$ In occerdonce mih appeeabp regulations. S- the ncsrI of $frudurol Jdnb Udna 0.725 or M90 Bette for moa Information. The fallowing criteria may be used to determine the bait Ityrinas (La. 'song -tight' or 'idly-prelemlon.d"), unless regdrad otherwise by local jurisdiction a centroct requirements: A All A490 bolts aho9 be 'fu9y-gebndoned'. O As A32D but In pdmay mooing (dgld from*$ and bMdrnq) may be 'snug -light; except ps fallow n n ALT2s bd1e� o BuldIng supports a crone system with a capacity greater than s tons. b) Building supports machln4ry that creates vibration, impact or strolls-meaois on the connections. The Engineer-d- Record for (he project should be wnsulted to evaluate for this canditim a) The project site is located in a high ee:emfo area. For IOC -based codas. 'High 5e1arnic Arco Is defined as 'Setendc Design Category' of 'D', 'V. or 'F'. See the 'Buil6ng tadi saloon of this page far the darned sdardc design category far this praisct. d) Any exmeetlorn dalgnolod in theme drawings as 'A325-SC'. '91IP-CdOaal (SC)' cancan— must be from or palm, ail, or otter moledab that reduce friction at contact eurfacoe. Goh,an$ed or HOW rusted ourfam oar occeptebte. C) In Canada, of A325 and A490 bats shall be 'fully pre-tenelonod'. except for secondary m= g1As, upardnq froming, ote,) and flange braces. O) Secondary membere purrna garb. opening rrombg, ola.) and Range broc, cerrlec9ans may drays be 'smog-Ught', unless Indicated othomfme in these drarirgs. 3) The metal bulding supplier shdi be notified prbr to any field mod(norUans. Modifications shall be atpmd by the metal bulding supp9m before work is endertaken. 4) Common AbbraMotlom: a TP LINO - Typical Unless Noted Othrawiaa q IM -Simian Ill SLV - Snort Leg Vertical q NIC - Not In Contract e LLV - Long Leg Vertical h SL - Steel Um d NS & FS - Near Side and Far Side i N/A - Not Apprcdda o DAL. - Onral Length I NIBS - Meld BuldMg Supplier 5) Construction loads shot not be placed an my structural stool framework unless much frmnaeark is sorely bated, welded, or otherwiso adequately secumd. 6) Purim and from she$ not be used - an anchooge point for a fall greet sydenn unless written appmal is obtained from the metal building supplier. 7) Purlm may only be used m a along/wadding surface when Installing o&cty gdeme, a b after all permanent bridging has Installed and fall protection provided. 0) C-.b..U- leads may be placed any rsNn a zee that is dUdn a fed of the I. ar line U the primary support memb. CFR bundles should be placed directly ovar the dgld fremes. 9) NI lifting devim must meet OSHA or MSiA standard. and In no case is R acceptable to use structural members supplied by the MBS as a spreader bar a lit" da,Rce_ PROJECT NUMBER: S 18JO839A PROJECT NAME: DG—E-9100 Zeph r�r hills, FL PROJECT LOCATION: Zephyrhills, FL 33542 CUSTOMER: Dollar General PRIMARY AND SECONDARY STEEL PRIMER COLOR: RED ROOF SHEETING, TYPE, SS 24 GAGE, FINISH: GoNalume ROOF PANEL CUP TYPE: Tall Floating THERMAL BLOCKS: Yes EPS FOAM SPACER: No SEAMING METHOD FOR CFR ONLY): 0-ROLL LOCK-' REFETR Tar HE OEfAA PAGES ranSE LOCK"TM OPAGES OR 1AMOMOTO HE OUMLMASE LOCK 360'Tm COMPOSITE CFR DECK, TYPE N/A —GAGE FINISH: ROOF LINE TRIM, PAINTED: Lightstone SP EXTERIOR WALL SHEETING. TYPE: RC 26 GAGE, FINISH: GaN01Ume EXTERIOR WALL CORNER TRIM FINISH: Gallolume EXTERIOR BASE TRIM, PAINTED: Lightstone SP FRAMED OPENING TRIM, PAINTED: Lightstone SP WALL FRAMED OPENING, SIZES: FSW (1) 6.3333 W x 7.1667 H SSW (1) 3.3333 W x 7.1667 H (1) 13.125 W x 10 H LEW (1) 13.125 W x 10 H REW none INTERIOR WALL SHEETING, TYPE: CL 28 GAGE. FINISH: Polar White SP INTERIOR CEILING LINER, TYPE _GAGE, FINISH: INTERIOR WALL TRIM, PAINTED: Polar White SP YES 1 NO ❑ General Des; n Note i NI structural Bled aectiow and weldd plots members are designed in ❑ accordance with ARSI/MSC 300 'Spoorkatkns for Structural Stool BoTdfnge' the CAN/CSA SIG 'UImR ; a.States Design of Steel Structures rpdrd by El the specfled building coda. 2) NI weldaq of structural steel is based an either AWS DIA "Structural Welding Code - Steel' or CAN/(SA W59 9Vddd Sod Conetruclim (Metal Are Welding)', or regrind by the gledfld building coda. 3) All add forma membme ore dwignd In accordance .lace ANSI/NS SII or CAN/CrJ4 S136 "r=McaUerw for the Design of Cold Formed Seel Structural Wmberr; m regdrsd by the specified building code. 4) NI welding of cold formed steel is based an AWS 01.3 structural Welding Code - Short St-r or CAN/CSA W59 welded Steal Construction (Metal Arc WaWtnq)', as required by the apedfld buli9ng coda. 5) This Meld Boll's Supyfor faanity 1. IAS AC-472 Accredited and CAN/CSA A A. ond W47.1 Certified IN applicable) far On design and manufacturing of Metal Building Syatems. 9) 9 jaists ore hkMdd with this project, they ore supped of a part of the systems engim - - meld bulling and ore fobdwtad In accordance with the requiromento of Section 1926.75E of tiro OSHA *$fay standards far steel sncUm. dated January Ia. 2D01. Material Specifications Plot. and Fbngo kctdab s" - 12. WTde, to 1 1 /4' Th. — A529 Code 55 Others A372 Code 50 Built -Up Structural Web Atoll SS (a HSLAS Came 1) Grad. 55 Hot -Ruled Structural A36 or A572 Grade 50 or A992 Code 50 Struduml Tube A500 Grodo B (46 09 Structural Rpe A500 Grade B 42 Ira) Cad -Farmed Structural Af011 or A1039 SS ( HSAS Cl-a 1) - ASS3 Grad. 55 ihm-Fastened Hoof Pond A792 Grade 50 Standing Sam Roof Pond A792 Cade 50, Coa t All Wail PgrnI Profiles AM Grads GO, a.. 1 or A792 Grad. 00, Close 1 Rod Bracing A529 Grade 50 Wells AWS 01.1/01.3 or CSA Wye par Building Cod. High-S1rengVn Baits A325 Type 1 OrA490 type I Havy Ha Machine Baia A307 Grade A Hex TPADEMW 19M NUCOR 91RIOM SYSTEMS ❑ DOWNSPOUTS PAINTED. Lightstone SP GUTTERS PAINTED: Ughtetone SP ❑ WALJ(DOORS. QUANTITY: 1/1 PAINTED: 3070PABR/6070PABR X WINDOWS: PAINTED: ❑ INSULATION (NOT BY MSS), ROOF: 6 INCH WALLS: INCH J$J CRANES (SEE CRANE PLAN FOR ADDITIONAL CRANE INFORMATION) MEZZANINE (SEE MEZZANINE PLAN FOR ADDITIONAL MEZZANINE INFO) ® WALL TRANSLUCENT PANELS: ROOF TRANSLUCENT PANELS: INSULATED PANELS YES ❑ NO ❑ j$J PIPE JACKS. SIZE: QUANTITY. Jg[ ROOF FRAMED OPENINGS, SEE ROOF FRAMING PLAN FOR SIZES JgJ RIDGE VENTS. 10'-0" LONG X 9" THROAT. QUANTITY: NJ All NO FASCIA, PROJECTION: TOP OF FASCIA HEIGHT, FACE PANEL, TYPE: _GAGE, FINISH: BACK PANEL, TYPE: _GAGE, FINISH: CAP TRIM PAINTED: BASE TRIM PAINTED: ❑ CLOSED SYSTEM, CLEAR UNDER SOFFIT TRIM: SOFFIT PANEL, TYPE: —CAGE. FINISH: SOFFIT TRIM AT BUILDING LINE PAINTED: ❑ OPEN SYSTEM, (NO SOFFIT PANEL PROVIDED) CLEAR UNDER FASCIA JK PARAPET SYSTEM ❑ STRUCTURAL PARAPET ❑ NON-STRUCTURAL PARAPET TOP OF PARAPET HEIGHT: BACKER PANEL, TYPE —GAGE, FINISH: ® CANOPY, PROJECTION• AT EAVE LINE ❑ BELOW EAVE ❑ ROOF PANEL. TYPE _ GAGE. FINISH: SOFFIT PANEL. TYPE: _ CAGE. FINISH: SOFFIT TRIM AT BUILDING LINE PAINTED: Kx IN CLEAR UNDER CANOPY BEAM* EAVE EXTENSION, PROJECTION: SOFFIT PANEL, TYPE _ GAGE, FINISH: SOFFIT TRIM AT BUILDING LINE PAINTED: RAKE EXTENSION, PROJECTION: SOFFIT PANEL. TYPE: _ GAGE, FINISH: SOFFIT TRIM AT BUILDING LINE PAINTED: J8J PARTITION WALL SHEETING PANEL TYPE: PARTITION WALL TRIM COLOR: J$j WAINSCOT WALL PANEL, TYPE: BASE TRIM PAINTED: — TRANSITION TRIM PAINTED: 1 �n t' ww trk�. it's:' CITY () ZyUE� DIN; OFFICIAL _fit _ GAGE, FINISH: GAGE, FINISH: JAMB TRIM PAINTED. M E M B E R 0 A00 09W V:m BUILDING LOADS DESIGN CODE: FBC ' 17 ROOF LIVE LOAD: 20.GD PSF MBMA OCC. CLASS: II LIVE LOAD REDUCIBLE Y-es GROUND SNOW LOAD: .0 PSF SNOW EXP. FACTOR, CIS:1.0000 SNOW IMPORTANCE FACTOR, Is: 1.00 WIND: 137 / 1D6 MPH (V.10 / (Wood) C & C PRESSURES (PSF): 37 / -50 EXPOSURE. C UL 90 NO Classic Roof -Co int. No.161 : Gawk Roof w/ Translucent Pond -Cool Nc.167 CFR Roof -Copal No.1552 T CFR Roof w/ Translucent Pond-Const. NcMO Composite CFR Roof-C.onst. No.552A : VRIG li Roaf-Conwt. No.= . SEISMIC INFORMATION Ss:0.054 S1:0.034 Design Sds/Sdt: 0.09D / 0.054 Site Class: D Seismic Imp. Factor: 1.00 Seismic Design Category: A AnncWs Procedure: Equivalent Lateral Force Method Basic SFRS: Not Gelded for SebrTda NOTES: 1) COLLATERN. DEAD LOADS, UNLESS OTHERMSE NOTED. ARE ASSUMED TO BE UNIFORMLY DErRW EO. WHEN SUSPENDED SPRINKLER SYSTEMS. UGNRIC, WAG EOIAPMENr. CEILINGS, ETC.. ARE SUSPENDED FROM ROOF MEMBERS. CONSIA.T THE M.B.S. F THESE CONCENTRATED LOADS EXCEED 500 (USING THE WEB MOUNT DETAIL) OR ZOD POUNDS (USING FLANGE MOUNT ODEOTNI� OR IINDIVIDUAL MEMBERS ARE LOADED SGNeRCANTLY MORE THAN UTHEAS. 2) ORE DESIGN OF STRUCTURAL MEMBERS SUPPORTING GRAVITY LOADS IS CONTROLLED BY THE MORE CRITCAL EFFECT OF ROOF UNE LOAD OR ROOF SNOW LOAD, /S DETERMINED BY THE APPLICABLE CODE. 3) Pm IS BASED ON THE MINIMUM ROOF SNOW LOAD CALCULATED PER BUILDING CODE OR THE COMRACT SPECIFIED SHOW LOAD, WHICHEVER IS GREATER, THIS VALUE, Pm, IS ONLY APPLIED N COIBINMTOR WITH THE DEAD AND COLLATERAL LOADS. ROOF SNOW IN OTHER LOADING CONDITIONS IS DETERMINED PER THE SPECIFIED 13UIIDING CODE ERECTION MANUALS REQUIRED (N MANUALS ARE SHIPPEID WITH THE BUILDING IN A WAREHOUSE PACKING CRATE) ® CFR ROOF ® H9700 OR O M8260 O SINGLE CURB (149850) O CLASSIC ROOF O H9420 OR O H8201 10 DOUBLE CURB (H9800) ® WALL SHEETING ® H9430 OR O H8300 10 VR16 R H9925 DRAWING INDEX COVERSHEET C1. C2 ANCHOR BOLT DRAWINGS Ft. F2 COLLrWN BASE REACTIONS STRUCTURAL/SHEETING DRAWINGS E1 - E8 DETAILS UJ Cn J J J Nto urw M F J MLL ') = Q J w WN WCj Z LIJ O U') <- U LM CvU)a,Q"= wO CO tli) O o J LU O U C()H O N No 84502 STATE OF s N N (m, 4 U s a Iz0�$15S $r VQ imm U DO $� cn cn M _I J U- U- J J N w CO _I co Q WN Z� -to Lu W O U 1.1.. J co • CO ',,, Q K 00 �• 002 3�0cl) J W ON Z m� �``�lt;TA�M9�'��i ��;Dy �ccEiJs� . P�; , No �. r 84502 :*f ;#� -b: # : z LAO�;. STATE OF ; 2� N 2 `��� f E,g�•e i� FOR BUILDINGS WITH AN OCCUPANCY I OR II, IBC ALLOWS FOR SINGLE STORY BUILDINGS TO HAVE NO LIMIT FOR THE SEISMIC STORY DRIFT. PLEASE NOTE THAT ANY INTERIOR WALLS, PARTITIONS, CEILINGS, AND EXTERIOR WALLS SHOULD BE DETAILED (BY OTHERS) TO ACCOMMODATE THIS STORY DRIFT. THIS PROJECT IS DESIGNED AS AN ENCLOSED BUILDING. ACCESSORIES (DOORS, WINDOWS, ETC.) BY OTHERS MUST BE DESIGNED AS "COMPONENTS AND CLADDING" IN ACCORDANCE WITH THE SPECIFIC WIND PROVISIONS OF THE REFERENCED BUILDING CODE. THE PRIMARY AND SECONDARY FRAMING MEMBERS HAVE BEEN LOADED FOR 2 ROOF TOP UNITS. THE ROOF TOP UNIT WEIGHTS ARE 1,800 LBS. SEE ROOF PLAN FOR LOCATIONS. THE PRIMARY AND SECONDARY FRAMING MEMBERS HAVE BEEN VERTICALLY LOADED FOR SATELLITE SUPPORT WEIGHING 1,000 LBS, BUT THEY ARE NOT DESIGNED FOR HORIZONTAL NOR MOMENT —INDUCING LOADS. SEE ROOF PLAN FOR LOCATION. VERTICAL SUPPORT OF THE 1400 LB. DOLLAR GENERAL SIGN TO BE SUPPORTED BY BRICK/MASONRY WALL (NOT BY NUCOR). 12" CHANNELS ARE SUPPLIED TO FIELD —LOCATE ON GIRTS TO PROVIDE HORIZONTAL SUPPORT OF SIGN. NUCOR MATERIAL DOES NOT PROVIDE VERTICAL SUPPORT FOR MASONRY. NUCOR MATERIAL WILL ONLY PROVIDE HORIZONTAL SUPPORT FOR MASONRY DUE TO WIND AND SEISMIC FORCES. WEIGHT OF MASONRY ASSUMED TO BE 45 PSF. LINTELS HAVE NOT BEEN PROVIDED BY NUCOR. THE PROJECT ENGINEER OF RECORD (NOT THE METAL BUILDING SUPPLIER) IS RESPONSIBLE FOR ASSURING THAT WALL COVERING (NOT BY MBS) ARE DESIGNED TO SAFELY WITHSTAND ALL CODE REQUIRED LOADINGS ASSOCIATED WITH THE GIRT AND PURLIN SPACING PROVIDED. THE SPANDREL CHANNEL WHICH SUPPORTS THE TOP OF THE MASONRY WALL MUST BE ATTACHED TO THE WALL AT 4'0 O.C. (MAXIMUM). THE DESIGN OF THIS ATTACHMENT IS BY OTHERS. THE MASONRY/CONCRETE WALLS (DESIGNED AND FURNISHED BY OTHERS) ATTACHED TO THE SPANDREL BEAMS ARE ASSUMED TO ACT AS SHEAR WALLS. THE CONNECTIONS (DESIGNED AND FURNISHED BY OTHERS) OF THE SPANDREL BEAMS TO THE MASONRY/CONCRETE WALLS MUST BE RIGID, AND MUST NOT ALLOW ANY SLIP TO OCCUR. o Dia= 3/4" B Dia=1 " 1 -m'—R"nt tT_Tn_m rr na CTCFI 6 High Eave 2 3 4 5 26'-8" 26'-0" 26'-0" 26--0" 26'-0" 13'-1 1 2" 10'-10 1/2" 3'-4' 16'-3" X-Bracing • L •H •H •H •H E F a• He - o o0 D ■• W I I I I cr w cis ao 01 rn br rn I I I a I HB r a� 101 re •� 101 ro •� 101 ro •� 101 DH L_°J L_°J L°_J L_°J 0 1 N N I of A G G Ge 0 0 G e X-Bracing 15'-4" 6'-4" 10 4'-4" 26'-8" 6'-0" 26'-0" 26'-0" 6'-0" 5 6) ANCHOR BOLT PLAN NOTE All Base Plates ® 100'-0■ (U.N.) N ANCHOR BOLT SUMMARY ro• Oty Locate in) Type tin 032 EndwaU yT/4' F1554 3.00 B 16 Frome 1 F1554 3.00 032 Frome 3/4' F1554 3.00 ANCHOR BOLT PLAN GENERAL NOTES I. THE SPECIFIED ANCHOR ROD DIAMETER A ASSUMES F1554 GRADE 36 UNLESS NOTED OTHERWISE. ANCHQR ROD MATERIAL OF Ln m a. EQUAL DIAMETER MEETING OR EXCEEDING THE STRENGTH REQUIREMENTS SET FORTH ON THESE DRAWINGS MAY BE UTILIZED AT=« THE DISCRETION OF THE FOUNDATION Y'1 T s DESIGN ENGINEER. ANCHOR ROD EMBED- s 2 d' R �y MENT LENGTH SHALL BE DETERMINED BY O N THE FOUNDATION DESIGN ENGINEER. _ 2. METAL BUILDING MANUFACTURER IS NOT RESPONSIBLE FOR PROJECT FOUNDATION ®MOB 3 DESIGN. THE FOUNDATION DESIGN IS THE RESPONSIBILITY OF A REGISTERED O` E $ U B g 4 PROFESSIONAL ENGINEER. FAMILIAR WITH LOCAL SITE CONDITIONS. O n I x Low Eave D d i 3. ALL ANCHOR RODS, FLAT WASHERS FOR ANCHOR RODS, EXPANSION BOLTS, AS WELL AS ALL CONCRETE/MASONRY EMBEDMENT PLATES ARE NOT BY METAL BUILDING MANUFACTURER. 4. THIS DRAWING IS NOT TO SCALE. 5. FINISHED FLOOR ELEVATION = 100'-0' UNLESS NOTED OTHERWISE. 6. 'SINGE' CEE COLUMNS SHALL BE ORIENTED WITH THE 'TOES" TOWARD THE LOW SAVE UNLESS NOTED OTHERWISE. 7. ANCHOR RODS ARE REQUIRED ONLY IN THE QUANTITIES SPECIFIED. BASEPLATES MAY BE FABRICATED WITH MORE HOLES THAN NEEDED FOR THIS PROJECT. 8. THE ANCHOR BOLT LOCATIONS PROVIDED BY METAL BUILDING MANUFACTURER SATISFY PERTINENT REQUIREMENTS FOR THE DESIGN OF THE MATERIALS SUPPLIED BY THE METAL BUILDING MANUFACTURER. PLEASE NOTE THAT THESE REQUIREMENTS MAY NOT SATISFY ALL ANCHOR BOLT CONCRETE EDGE DISTANCE REQUIREMENTS DEPENDING ON THE DETAILS OF THE FOUNDATION DESIGN. BECAUSE FOUNDATION DESIGN IS NOT WITH— IN THE METAL BUILDING MANUFACTURER'S SCOPE OF WORK, IT IS THE RESPONSIBIL— ITY OF THE QUALIFIED PROFESSIONAL DESIGNING THE FOUNDATION TO MAKE CERTAIN THAT SUFFICIENT CONCRETE EDGE DISTANCE IS PROVIDED FOR THE ANCHOR BOLTS IN THE DETAILS OF THE FOUNDA— TION DESIGN. ULL in J _I —j _ NLO w M J ch r CLIL Q J u"5 N W W N N L' � Z W J O wQ UwIY� = Q M 0 W rn w 0o J W o W j 00 No 84502 STATE OF �a e, $, 9 #s ix tiN-- 'Egi='�gg 0 o p .ebz`^ L NOS -j 12 81M €"='s9. con-q 8„ `-9OoO01.1 Dia= w 3/4" p\ i all_T 00 010 0110 00 O O °° 2„ 4.. 1 00 010 8" 2„ 2„ DETAIL A EW � 2„ I 2„ 1 —0 DETAIL E Dia= 3/4" 5 10.1 0 L O O � O _ ��• ; 6„ 6„ O O 1 1 /2" 2»CL � 2" DETAIL I Base EL. 99'-4" 8" 1p I I W °fprre 8.. —T— °° o' 9O 0 4' F 00 00 0 �0 I� 2„ I ]4" _—�—_ 00 010 2" 2" 2" 8"1 --L— Sw EW 2»W� 2» See Plan 4j DETAIL B DETAIL F Dia= 3/4" Dia= 3/4" 3 �o�, V) Q„ 9O pro Q» I�--=T---I{ ( FOUNDATION DESIGN NOTES: a0 O (O O 0110 1. THE ORIENTATION OF THE ANCHOR BOLT DETAILS SHOWN ON THIS PAGE MAY NOT 4" ( I 4" COINCIDE WITH THE ACTUAL COLUMN ORIENTATION SHOWN ON PAGE Ft. PLEASE 00 O 1 O 0 1 0 REFERENCE THE SIDEWALL (SW) AND ENDWALL (EW) STEEL LINES SHOWN ON THE ANCHOR BOLT DETAILS WITH THE ANCHOR BOLT PLAN ON PAGE F1 DURING LAYOUT 2" 4" —�— EW —'�— SW OF COLUMN AND ANCHOR BOLT LOCATIONS. 2. COLUMN BASE PLATES MAY HAVE MORE HOLES THAN ARE REQUIRED DUE TO PRODUCTION LIMITATIONS. PLEASE FOLLOW ANCHOR BOLT DETAILS FOR QUANTITY 2 ' 2" 2" 2' OF ANCHOR BOLTS REQUIRED. EXTRA BASE PLATE HOLES DO NOT NEED INFILLED 1-4� See Plan PER THE MBS DESIGN SPECIFICATIONS. DETAIL C DETAIL G Dia= 3/4" Dia= 1 " q 8" 9�°�p�` 8" 2" O �F-1'—COUJMN CLR. OPENING VARIES: OD ( - 'o COLUMN 21"-3$" O 1 14" 1 4,. a (USE (2) 1/2" DIA EXPANSION O o m FINISH BOLTS PER COLUMN) a G0 O � O n '� FLOOR GIRT DEPTH + 2" '- ' .1. 2" 4" —EW Sw ~ANCHOR~ BOLT _ v ANCHOR BOLT 2" 2" 2" 2" 02 'f SECTION A a m m See Plan See Plan '`'f "=0 "+ - (RECOMMENDED) TYPICAL OVERHEAD DOOR eaeFFNc DETAIL D DETAIL H TYPICAL COLUMN BASE PLATE DETAIL FRAMED OPENING TYPICAL COLUMN BASE PLATE DETAIL LJL.. O) J J = C'4 w co co Ta.LL- WN LU C ZJ J QO 0 _ m U �0 w� W co J d ? O aC700 CO 0 UJI mono No 84502 STATE OF l� 04 4-- O N LL PURLIN LAP FUph Em — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — I I I I I I I I I I I I I I 1XI I I I I I Q>/ Q>/ I I I I ( I I i I I I f I z a I I ( I ( I I I I I i I I I i I I ( ( I ( I I I 4'-0 s/P z'-s �/h Y-s vh 4'-0 s/4� Law Enos 4-0 31r z-s 1/4• r-s 1/4• a-0 s/,V ROOF FRAMING PLAN J LL_ J J CL W N O w O ICP No 34502 STATE OF s3a�e�S w s � gm N Ii EoerismSS Q �em ti E mv�i 5om 51f 5 SKEWED ENTRYWAY/SOFFIT SUPPORT PURLINS PLAN PURLINS FOR SOFFIT SUPPORT AT 10' ELEVATION N d' C[) Cl) J J � LL Cn J J J C'4 w J = u') co = J th' Q J y w N Z J_ Qo ) C9 = w � U � c7 p le 00 �rn JCL oC9Mu�iON mW No 84502 STATE OF 00 0 N W Wgh Eave �-----7 — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — --- ----------------------------� I I I I I I � I � I I I I I 9_ 1 i fA i 1 n • 6�� a 10'-10' 5'-0' ' 0 2 I I I I I I I 1 I I 9'-5 1 /1 V + 7'-1 7/8" 9'-5 1 /16" + 7'-1 7/8' - i N LO co I I co 1 1 J t 1 1 LL- 1 I 1 J� v LO I = co n! >- J m I I =w � i Lu N Z T/i I I NL cc Lu_ o OPENING TABLE W rn Q cowl= ID WIDTH ft LENGTH ft WEIGHT kips I a ap j Q UU N 1 1 5'-0' 5'-0" 1.000 1 30 m 1 21 4'-2 5 8" 7'-1 7/8-1 2.000 1 1 31 4'-2 5 8" 7'-1 7 8" 1 2.000 1 ad���re irrr�4 I I L----------------------------------------------------------------------------------J —4 Stott ROOF SHEETING PLAN PANELS: 24 Oa. SS - 0" me NOTE: USE VISE LOCK SEAI9NG FOR ENTIRE ROOF STANDARD CUPS (2) FASTENERS. 1 _4! _" Eaw Pond Star! No 84502 %tlk STATE OF f=�� %� �g�Yog v, 00 $g'x O oc` w m 0 N O m N m ✓i 2*-0" 3 ®5'-0' 2 05'-0" 2'-0 '5 8' 16' 1�-it 15/16' -0 1 5 05'-0' 4'-0 7 16' FB g' fA' $S8a �1) FB fig{ 72 A S^5 �1) v— ) FBC 1) -- FBC�V 1— FBC3�) O o ^ 8 61 U ri RFi-2 N J i3 N pl to -!7771 c- RF _ e' =I e$ - I cl to I io m m 1 1 tV CI p I 1 M+ I �D In+ tD •- 17 M U N Lo LYJ 0 o M I I J Y a LL J N -0" 47'-0' 1 "-0" V-0" _ M Ir- CLEAR + - CLEAR LL 48'-0' 22'-0" 11.E N Z J 0'-0' OUT -TO -OUT OF STEEL C NO W r A D O _ Q w 0) RIGID FRAME ELEVATION: FRAME LINE 2 3 4 5 Q= m o 0 �00 coo -S W Z o0 �QcnUopN RU) TA '�`P��•`'1tF�7s` :Psi. SO7 No 84502 iLuu? T STATE OF } Se x '11 co 9.5q"4G3i A • al -a g9I9$! 0 2'-3- 2'-6- 130'—$"0Ur—M-0UIr OF STEEL T26'-8* 20,-0, I26--0- 26'-0" 26.-0. — — — — — — — — — — — — — — — — WALL BY OTHERS — — — — — — — — — — — I — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — 1 — — — — 3 E — — I H SIDEWALL FRAMING: FRAME UNE D THE MASONRY/CONCRETE WALLS (DESIGNED AND FURNISHED BY OTHERS) ATTACHED TO THE SPANDREL BEAMS ARE ASSUMED TO ACT AS SHEAR WALLS. THE SHEAR WALLS ARE TO BE DESIGNED TO RESIST A UNIFORM LOAD OF 0.72 KIPS/FT OF WIND FORCE. AND 0.03 KIPS/Fr OF SEISMIC FORCES APPLIED AT THE HEIGHT OF THE SPANDREL BEAMS AND PARALLEL TO THE7—WAU-S. THE CONNECTIONS (DESIGNEE —AND FURNISHED BY OTHERS) OF THE SPANDREL BEAMS TO THE MASONRY/CONCRETE WALLS MUST BE RIGID, AND MUST NOT ALLOW ANY SLIP TO OCCUR. 1 15'-4' 6'-4- 4'-I-j No 84502 STATE OF rg ig a 00 .3 LO W 16'-7' �3'-4'I L 10'-10 1/2" 13'-1 1/2' ". SIDEWAU_ FRAMING: FRAME UNE A THE MASONRY/CONCRETE WALLS (DESIGNED AND FURNISHED BY OTHERS) ATTACHED TO THE SPANDREL BEAMS ARE ASSUMED TO ACT AS SHEAR WALLS. THE SHEAR WALLS ARE TO BE DESIGNED TO RESIST A UNIFORM LOAD OF 0.70 KIPS/FT OF WIND FORCE, AND 0.04 KIPS/FT OF SEISMIC FORCES APPLIED AT THE HEIGHT OF THE SPANDREL BEAMS AND PARAU.EL TO THE WALLS. THE CONNECTIONS (DESIGNED AND FURNISHED BY OTHERS) OF THE SPANDREL BEAMS TO THE MASONRY/CONCRETE WALLS MUST BE RIGID. AND MUST NOT ALLOW ANY SUP TO OCCUR. A N et C+7 C7 J J LL LL J J N J = LO CL J CL =W W N Z N� WJ C� 0 _ rgw--Vcp �� L w � W J IL CA � J aC�c°Ooy0N No 84502 STATE OF �f At , 0 N N ' O m C] N O] A 70'-0OUT-TO- )UT OF SIID. 0 L" B C 22'-0' 26'-0" 22'-0- 3/6' y §§tea �a ge .1 R. fil 9Al 03 V-9 3/4 t I 'v a !� N I t �D I I cp (V 10 j C14 M to 'co M o c 0 o o o J U- U- U J J = tWALL w OTHERS WALL BY OTHERS I d' = J cM — J T CL = W Q J t� m FI I I I W N W ZJ I I N Q 13'-1 1/2• 6'-10 1/2' (] U w } M GIRT vas �2 -,, ,�� „ r-,/s °' ,n W�rn Q = wJ J CO w O 9 -5 ENDWALL FRAMING: FRAME UNE 1 a co U Oo N o CO Meo No 34502 rLi 9SE.Kneg CO W i+ ", M REQUIRED NATIONAL ACCOUNT VENDORS COMPANY CONTACTS PHONE # REQUIRED ITEMS W RAINBIRD IRRIGATION LOCAL RAIN BIRD DISTRIBUTER WWW.RAINBIRD.COM IRRIGATION SYSTEMS CO F U EUCLID CHEMICAL PHIL BRANDT 877-438-3826 CONCRETE POLISHING SYSTEMS Of Z E_ COMPANY PBrandt@euclidchemical.com z z J RETRO-PLATE SYSTEMS SCOTT MAXFIELD 801-641-6796 CONCRETE POLISHING SYSTEMS o 00 scott.maxfield@retroplatesystem.com RECORD DOOR SYSTEMS MICHAEL VINNIK 704-290-0234 IN,KY,MD, MODEL #5100 SERIES dollargeneral@recorddoors.com OH, PA,VA,WV � o UJ STANLEY ACCESS DENNIS WEBB 256-776-8902 AR,AZ,CA,CO,CT,DE,IL,IA,KS,LA,MA,ME,MI,MN,MO, MODEL #DG2000 W Z TECHNOLOGIES DGdoors@sbdinc.com ND, NE, NH, NJ, NM,NV,NY,OK,OR,RI,SD,TX,VT,WI of � ASSA ABLOY ENTRANCE ROSS MERKLING 609-528-2580 AL, FL, GA, MS, NC, SC, TN MODEL #SL500 n w SYSTEMS us@assaabloy.corr GIRTMAN AND ASSOCIATES MIKE MOYNAHAN 615-350-6000 INTERIOR DOORS AND FRAMES AL,AR,AZ,CA,CO,FL,GA,IA,KS,LA,MS,MN, rn o dgconstruction@bass-security.com AND RESTROOM ACCESSORIES MO,NE,NM,NV,OK,OR,SC,SD,TN,TX,WI o Of w o COOK & BOARDMAN GROUP JOE HARRELL 336-837-0673 INTERIOR DOORS AND FRAMES CT,DE,IL,IN,KY,MA,MD,ME,MI,NC,NH,NJ, o z o nationalsales@cookandboardman.com AND RESTROOM ACCESSORIES NY,OH,PA,RI,VA,VT,WV w SHERWIN WILLIAMS LOCAL SHERWIN WILLIAMS STORE PAINT, PRIMER, CONCRETE SEALER AND BLOCK FILLER z MC CUE CORPORATION KEVIN O'NEILL 678-492-4026 koneill@mccue.com TRIM KIT INCLUDES BUMPER GUARDS AND CART STOP U_ YORK NATIONAL ACCOUNTS 800-481-9738 HVAC UNITS york-dollargeneral-be@jci.com AR, CO, IL, IN, KY, KS, MO, OH, OK, WV CARRIER HASAN KHALIL 315-432-7655 HVAC UNITS Hasan.Khalil@carrier.utc.com CT, IA, MA, ME, MI, MN, ND, NE, NH, NJ, NY, PA, RI, SD, VT, WI Q t LENNOX SCOTT MACDONALD 972-497-6781 HVAC UNITS = Z) dollargeneral@lennoxind.com AL, AZ, CA, DE, FL, GA, LA, MD, MS, NC, NM, NV, OR, SC, TN, TX,VA ROOF CURB SYSTEMS CLIFTON REASOR 800-683-5848 RTU CURB DollarGenerar@roofcurb.com CURBS PLUS INC. ALLAN THRAILKILL 888-639-2872 RTU CURB alan.thrailkill@curbs-plus.com rn a KCC INTERNATIONAL INC. GREG CONRAD 800-382-2872 RTU CURB _ gconrad@kcccurbs.com Q CED - CONSOLIDATED ROBERT DECKER 270-781-2229 ELECTRICAL SWITCH GEAR AR,AZ,CA,CO,IA,IN,IL,LA,KS,KY,MI,MN, = ELECTRICAL DISTRIBUTORS robertd@cedbgky.com MO,MS,ND,NE,NM,NV,OK,OR,SD,TX,WI w � a NESCO CHRIS TRACY 800-244-6980 ELECTRICAL SWITCH GEAR AL,CT,DE,FL,GA,MA,MD,ME,NC,NH,NJ, w cn w dollargeneral@needhamelectric.com NY,OH,PA,RI,SC,TN,VA,VT,WV USLED DANA PORTER 713-337-3836 ELECTRICAL LIGHTING AR,CO,IA,IL,IN,KS,KY,MI,MN,MO, Z PAUL JEZIOROWSKI DGUSLED@usled.com SUPPLIES ND,NE,OH,OK,SD,WI,WV = LEDS MICHAEL STRINGER 920-915-4010 ELECTRICAL LIGHTING AL,AZ,CA,CT,DE,FL,GA,LA,MA,MD,ME,MS J KYLE KNAPP DGORDERS@Zeds-Ilc.com SUPPLIES NC,NH,NJ,NM,NV,NY,OR,PA,RI,SC,TN,TX,VA,VT D&P CUSTOM LIGHTING NATIONAL ACCOUNT SALES 800-251-2200 CUSTOM POWER POLES CROSSCOM NATIONAL ANDREA LEMAY 847-850-6297 LOW VOLTAGE & VOICE/DATA CO,CT,DE,FL,IA,IL,IN,KS,MA,MD,ME,MI,MN, Q� dollargeneral@crosscomnational.com MO,ND,NE,NH,NJ,NY,OH,PA,R1,SD,VT,W1,WV C'/-) ASD CHRIS RUDNITSKI 828-624-1046 LOW VOLTAGE & VOICE/DATA AL,AR,AZ,CA,GA,KY,LA,MS,NC,NM,NV, 0 0 crudnitski@asd-usa.com OK,OR,SC,TN,TX,VA GRAYBAR JEROME BANNISTER 615-743-3202 office, 615-924-2135 cell CABLE TRAY DollarGeneral@graybar.com EMERSON CLIMATE WEBSITE: USER NAME: dollargeneralbid EMS SUPPLIER NOTE: CUSTOMIZED DOLLAR GENERAL EMS PANEL REQUIRES L) TECHNOLOGIES http://dollargeneralbid.ectsolutions.net PASSWORD: dollargeneralbid STORE #, CITY, STATE, ZIP CODE & QTY. OF HVAC UNITS OF THE INSTALL SITE WHEN ORDERING. J STANLEY CONVERGENT DAN GOLDSMITH 740-215-8913 INTERIOR FIRE ALARM PANELS w SECURITY SOLUTIONS RECOMMENDED NATIONAL ACCOUNT VENDORS PRE-ENGINEERED METAL BUILDING COMPANY CONTACTS PHONE # VP BUILDINGS DAVID ENGLISH 901-568-4537 PRE-ENGINEERED METAL BUILDING DEnglish@vp.com STAR BUILDING SYSTEMS JEFF HORN 866-664-8899 PRE-ENGINEERED METAL BUILDING NUCOR BUILDING SYSTEMS BOB BARRY 315-622-4440 PRE-ENGINEERED METAL BUILDING CORPORATE: 260-837-7891 https://www.formrouter.net/forms@MBSIN/dgquote.pdf BIG BEE STEEL BUILDINGS, INC. KEVIN BUSLER 800-633-3378 PRE-ENGINEERED METAL BUILDING CHIEF BUILDINGS ERIN SULLIVAN 308-385-4628 PRE-ENGINEERED METAL BUILDING erin.sullivan@chiefind.com IRRIGATION COMPANY CONTACTS RAIN BIRD IRRIGATION LOCAL RAIN BIRD DISTRIBUTER WVWV.RAINBIRD.COM IRRIGATION SYSTEMS REQUIRED NATIONAL ACCOUNTS FOR ENGINEERING AND CONSTRUCTION MATERIAL TESTING COMPANY CONTACTS PHONE # ATC ASSOCIATES, INC. LESLIE GREENWOOD 205-733-8775 www.atcassociates.com leslie.greenwood@atcgc.com BUILDING AND EARTH MATT ADAMS 205-836-6300 www.buildingandearth.com SCIENCES, INC. dollargeneral@buildingandearth.com EAS PROFESSIONALS, INC. JERRY MARRONE 864-234-7368 www.eas-pro.com dollargeneral@eas-pro.com PROFESSIONAL SERVICE TERESA HEBNER 770-424-6200 #3030 www.psiusa.com INDUSTRIES, INC. (PSI) teresa.hebner@psiusa.com TERRACON JOHN MEADOW 770-623-0755 #353 www.terracon.com dollargeneral@terracon.com NOTE: MATERIAL TESTING IS REQUIRED ON ALL TRIPLE NET LEASES. PROTOTYPE MANAGEMENT TEAM COMPANY CONTACTS PHONE # MJM ARCHITECTS GARY CONWAY 615-244-8170 www.mjmarch.com dg@mjmarch.com ENTECH MITCH SIMPSON 615-373-2640 www.entechtn.com email@entechtn.com NATIONAL ACCOUNT & CONTACT INFORMATION SUBJECT TO CHANGE DOLLAR GENERAL STORE Store#20360 38965 CR 54, Zephyrhills, Florida 33542 Based on 9,100 SF Prototype T " (Left Corner Entry, Right Side Delivery) release date: 0 3/ 2 0/ 2 0 1 8 Product Avoroval Information Sheet Protect Name: Dollar General—Zaphvrhills (City of Zapirwhitls), FL Project. Address: 38965 CR 54 Z J � a z o w won 02 D p 0� 'r' O O Z w Q w (A m w Zco O H a- U E e�� ee MM0 �olwwwww . MMOOEIM 000000 C ■■❑❑❑■ ■■❑❑❑■ ■■❑❑❑■ ■■❑❑❑■ ■■❑❑❑■ GENERAL: CS COVER SHEET OWNER: F1 FIXTURE PLAN / LIFE SAFETY PLAN ARCHITECTURAL: A00 ARCHITECTURAL SITE DETAILS Al FLOOR PLAN A2 EXTERIOR ELEVATIONS A3 SECTIONS AND DETAILS A3a SECTIONS AND DETAILS A3b SECTIONS AND DETAILS A4 ROOM FINISH SCHEDULE AND SALES FLOOR ELEVATIONS A5 DOOR SCHEDULE AND DETAILS A6 ENLARGED PLANS AND TOILET ROOMS A7 SIGN DETAILS A8 SIGN BRACING DETAILS A9 REFLECTED CEILING PLAN A10 WALL TYPES All GENERAL NOTES Al2 ARCHITECTURAL SPECIFICATIONS STRUCTURAL: S1 STRUCTURAL GENERAL NOTES S2 FOUNDATION PLAN AND SCHEDULES S3 FOUNDATION SECTIONS AND DETAILS S4 SECTIONS AND DETAILS S5 CONCRETE SUMMARY MECHANICAL: ■ ■ ■ ■ M1 HVAC LAYOUT ,MEN M2 HVAC SCHEDULES / NOTES / DETAILS PLUMBING: ■ ■ ■ ■ P1 PLUMBING PLANS AND SCHEDULE ■ ■ ■ ■ P2 PLUMBING DETAILS AND DIAGRAMS ELECTRICAL: ■❑❑❑❑■ ■❑❑❑❑■ ■■❑❑❑■ ■■❑❑❑■ ■■❑❑❑■ ■■❑❑❑■ ■■❑❑❑■ ME] [IN ■❑❑❑❑■ ■■❑❑❑■ E1 POWER PLAN E2 LIGHTING PLAN E3 POWER POLE AND POWER TERMINAL DETAILS E4 CABLE TRAY LAYOUT PLAN E5 THREE PHASE ELECTRICAL PANELS EMS1 EMS / LOW VOLTAGE PLAN EMS2 CPU TERMINAL DIAGRAM ES1 ELECTRICAL SITE LIGHTING AND POWER PLAN ES2 SITE LIGHTING PHOTOMETRICS PLAN ES3 SITE LIGHTING FIXTURE CUT SHEETS As required by Florida Statute 553.842 and Florida Administrative Code 913-72, please provide the information and product approval number(s) for the building components listed below as applicable to thebuildingconstruction project for the permit number listed above. You should contact your product supplier if you do not know the product approval number for any of the applicable listed products. Information regarding statewide product approval may be obtained at: www_flonciabuildina.oro. Category Manufacturer Product Description Limitation of Use Product Approval A. Exterior Doors Swinging Curries Doors Outswing Commercial Steel Approved for use in +601-60 FL 8394.1 — R5 Door HVHZ psf (Pair) (Pair) +801-80 FL 8394.3 — R5 psf (Single) (Single) Category Manufacturer Product Description Limitation of Use Product Approval A. Exterior Doors Automatic Assa Abloy Entrance Besan Resilience Full Breakout Approved for use in +701-70 FL 16128.1 — R3 Systems US Inc. Bi-part Large and Small Missile HVHZ Impact Door System Category Manufacturer Product Description Limitation of Use Product Approval C. Cladding EIFS Dryvit System EIFS over 518" Sheathing, for Approved for use in +1101-110 FL 2030.5 — walls less than 30 feet HVHZ Psf R10 n, Stnrafrnnt Storefront Kawneer Series'IR-500 Flush and Wet FL 8787.2 — R5 �Approvedfbrusein Glazed" Aluminum Storefront HVHZ �+651-65 psf System — L.M.I. E Metal R uilriinn Manidar_turar WFUR3 Metal Wall Panels Nucor Building Reverse Classic wall Panel I Not approved for +45.01 FL 2686.3— R5 Systems use in HVHZ -45 psf Roof Deck Nucor Building CFR Panel Not approved for +NIA1 FL 4890.1 — R8 S stems I use in HVHZ -108:8 psf In addition to completing the above list of manufacturers, product description and State approval number of the products used on this project, it is the Contractor's or Authorized Agent's responsibility to have a legible copy of each manufacturer's printed instructions, along with the list above, on the jobsite available to the inspector: COMPONENTS AND CLADDING DESIGN WINDLOAD PRESSURE: 137 mph (vult) ROOF Oj +18 psf �0' -43 psf \0' O +18 psf h=19'-9' 3 2 3 -72 psf 55 O +18 psf 2 lO 2 -108 psf O O 3 2 3 WALLS 0 +43 psf 5 O O O -46 psf O5 +43 psf a=7'-0" TYP -57 psf 130'-8" STRUCTURE IS NOT LIGHT FRAME TRUSS CONSTRUCTION 4 Cii7f''y OF Z jg;f�i-f 'U5`• >ri1NC O,'d FJCIA. t, GENERAL NOTES: BUILDING MUST COMPLY WITH ALL BUILDING (FEDERAL, STATE AND LOCAL), FIRE, ADA AND HEALTH DEPARTMENT CODES. NO TAPERED COLUMNS ALLOWED. MAINTAIN INTERIOR CLEAR SPACE AS REQUIRED ON PLANS. METAL BUILDING COLUMNS SHALL BE STRAIGHT. COLUMNS AND INTERIOR COLUMNS MAY REQUIRE WRITTEN APPROVAL. MAINTAIN INTERIOR CLEARANCE BETWEEN FACE OF COLUMNS AND SALES FLOOR AS NOTED ON PLANS PROTECT OPENINGS NOTE: ALL NEW FIRE WALLS REQUIRED TO PREVENT THE PASSAGE OF SMOKE AND FIRE SHALL BE IDENTIFIED WITH WORDING "FIRE AND SMOKE BARRIER -PROTECT OPENINGS PER NFPA 101:8.3.2.4 LIGHT FRAME TRUSS NOTE: THIS PROJECT DOES NOT USE LIGHT FRAME TRUSS CONSTRUCTION CONSULTANT: SEAL: JOHN BENEDICT POLSINELLI, AR96059 I THIS DRAWING SHALL NOT BE USED FOR CONSTRUCTION PURPOSES UNTIL THE SEAL AND SIGNATURE OF THE RESPONSIBLE REGISTRANT APPEARS ON THE DRAWING, AND PROPER PERMIT FORMS AND RELATED FEES ARE TRANSMITTED BY THE OWNER, OWNER'S AGENT OR CONTRACTOR TO THE AUTHORITY HAVING JURISDICTION. DATE ISSUED FOR REV 09/27/201 8 PEMB COORDINATION 1 2/1 8/201 8 PERMIT SUBMITTAL 01 /1 1 /201 9 OWNER REVIEW 02/07/2019 BID SET 03/04/20191 ADDENDUM 01 IAN Project Manager Drawn L. LONG B. JACKSON Project Leader Checked L. LONG G. KARANFILOVSKI Date Dept Mgr Approval 08/07/201 8 G. KARANFILOVSKI Client PALMETTO ZEPHYRHILLS-20th St, LLC P.O. BOX 1615 THOMASVILLE, GA 31 792 Office: (229) 226-0682 Contact: John Tate Project DOLLAR GENERAL 38965 CR 54 Zephyrhills, FL 33542 (City of Zephyrhills) Store #: 20360 Drawing T'rtle COVER SHEET DO NOT SCALE DRAWIN ' Project No. Drawing No. .JCDT.18.0233 CS EMERGE LIGHTS ELECTRI PANELS EMERGE LIGHTS m 0 Awk @ ESM-10 VR-10 COKE ESM-10 29, PEPSI PEPSI [ I I I-1 L[J A - SERVICE COUNTER PLAN B - ELEVATION SERVICE COUNTER DETAILS Scale: 1/4" = V-0" NOTE: FRONT CHECKOUT COUNTER TO BE PROVIDED BY DOLLAR GENERAL AND INSTALLED AT DOLLAR GENERAL'S DIRECTION. COUNTERS SHALL INCLUDE A PORTION OF AT LEAST 36" IN LENGTH WHICH IS NO MORE THEN 34" ABOVE THE FINISH FLOOR. COUNTERS SHALL BE ON AN ACCESSIBLE ROUTE. ECK WRITING SURFACE (:6 ) ( 5) (:4 (: 3 ) FIXTURE PLAN / LIFE SAFETY PLAN Scale: 3/16" = V-0" BUILDING CODE COMPLIANCE BUILDING CODE V 2017 FLORIDA BUILDING CODE 5th EDITION V 2017 FLORIDA FIRE PREVENTION CODE 5th EDITION 2017 FLORIDA PLUMBING CODE 5th EDITION 2017 FLORIDA MECHANICAL CODE 5th EDITION 2014 NFPA 70 NATIONAL ELECTRIC CODE 2017 FLORIDA ACCESSIBILITY CODE (CHAPTER 1 1) 5th EDITION 2017 FLORIDA ENERGY CODE (CHAPTER 13) 201 5 NFPA 101 LIFE SAFETY CODE OCCUPANCY (M) MERCANTILE (S 309) (S-2) STORAGE, SEPARATED (S 31 1 .3) CONSTRUCTION CLASSIFICATION II-B NOWSPRINKLERED (T 601) MIN INTERIOR FINISH CLASS 'C' (T 803.11) BASE HEIGHT & AREA LIMITATIONS MAX HEIGHT- STORIES = 2 STORIES (T 504.4) MAX HEIGHT- FEET = 55 FEET (T 504.3) MAX ALLOWABLE AREA PER FLOOR (Aa) = 12,500 SQ FT (T 506.2) Aa = 112,500 + [12,500 x 0]) = 12,500 ACTUAL BUILDING PROPERTIES ACTUAL AREA = 9,100 SQ FT ACTUAL HEIGHT (OVERALL) = 2V-4" FIRE RESISTANCE RATING REQUIREMENTS (T 601) STRUCTURAL FRAME = 0 HR BEARING WALLS- EXTERIOR = 0 HR BEARING WALLS- INTERIOR = 0 HR NON -BEARING WALLS- EXTERIOR = 0 HR NON -BEARING WALLS- INTERIOR = 0 HR FLOOR CONSTRUCTION = 0 HR ROOF CONSTRUCTION = 0 HR DESIGNED OCCUPANT LOAD (T 1 004.1 .2) SALES FLOOR (7,298 sf/ 30) = 244 OCCUPANTS BREAK ROOM and OFFICE (147 sf/ 100) = 2 OCCUPANTS TOILET ROOMS and HALL (249 sf/ 100) = 3 OCCUPANTS RECEIVING (990 sf/ 300) = 4 OCCUPANTS TOTAL OCCUPANT LOAD = 253 OCCUPANTS EGRESS REQUIRED/ PROVIDED: # EXITS REQUIRED AND PROVIDED: GROUND 2 REQ'D / 3 PROVIDED (T 1006.3.1) EXIT WIDTH REQUIRED 0.20"/ PERSON EXIT CAPACITY REQUIRED = 50.4" EXIT CAPACITY PROVIDED = 170" (S 1005.3.2) MAXIMUM LENGTH OF EXIT ACCESS TRAVEL NOT TO EXCEED "M' = 200'-0" (T 1017.2) ACTUAL MAX. TRAVEL DISTANCE = 1 1 7'-4" PLUMBING FACILITIES REQUIRED: (T 403.1) PLUMBING FACILITIES PROVIDED: WATER CLOSET LAVATORY OCCUPANTS WATER CLOSET LAVATORY EA. SEXREQ'D REQ'D PROV'D NON -GENDER 126 1 per 500 1 per 750 UNISEX 1 1 NON -GENDER 126 1 per 500 1 per 750 UNISEX 1 1 DRINKING FOUNTAIN 1 PER 1000 (1) SERVICE SINK PROVIDED (1) HIGH/LOW DRINKING FOUNTAIN PROVIDED EMERGENCY LIGHT W/ BATTERY BACKUP '[ [ LIGHTED EXIT SIGN W/ BATTERY BACKUP DENOTES PATH OF EGRESS REMOTENESS BETWEEN EXITS DIAGONAL DIMENSIONS = 144'-0" SEPARATION OF EXITS = 144'-0" - 2 = 72'-0" ACCTUAL DISTANCE BETWEEN EXIT DOORS IS: 104'-8" DENOTES 2A1 OBC FIRE EXT. W/ TOP @ +42" A.F.F. F.E. MAXIMUM 75 FEET TRAVEL DISTANCE TO REACH FIRE EXTINGUISHER CONSULTANT: SEAL: JOHN BENEDICT POLSINELLI, AR96059 THIS DRAWING SHALL NOT BE USED FOR CONSTRUCTION PURPOSES UNTIL THE SEAL AND SIGNATURE OF THE RESPONSIBLE REGISTRANT APPEARS ON THE DRAWING, AND PROPER PERMIT FORMS AND RELATED FEES ARE TRANSMITTED BY THE OWNER, OWNER'S AGENT OR CONTRACTOR TO THE AUTHORITY HAVING JURISDICTION. DATE ISSUED FOR REV 09/27/201 8 PEMB COORDINATION 1 2/1 8/201 8 PERMIT SUBMITTAL 01 /1 1 /201 9 OWNER REVIEW 02/07/201 9 BID SET 03/04/201 9 ADDENDUM 01 01 Project Manager Drawn L. LONG B. JACKSON Project Leader Checked L. LONG G. KARANFILOVSKI Date Dept Mgr Approval 08/07/2018 G. KARANFILOVSKI Client PALMETTO ZEPHYRHILLS-20th St, LLC P.O. BOX 1615 THOMASVILLE, GA 31792 Office: (229) 226-0682 Contact: John Tate Project DOLLAR GENERAL 38965 CR 54 Zephyrhills, FL 33542 (City of Zephyrhills) Store #: 20360 Drawing Title FIXTURE PLAN / LIFE SAFETY PLAN DO NOT SCALE DRAWING Project No. Drawing No. .JCDT.18.0233 F1 R� � ^���. -, ..:� "'r', � * ,. - � � •€..,rrm^ "S'�'�. f '^IT?!""'"'Ei "'fFT". ��i^a"I"1' i-_.q.,r Rim, DRINK FIXTURE WALL MOUNTING SUPPORT NOTES: 1. PROVIDE AND INSTALL 2X6 WHITE PINE - GRADE 2 OR BETTER. 2. PROVIDE AND INSTALL 2X4 WHITE PINE - GRADE 2 OR BETTER. 3. FASTEN THE 2X6 TO THE WALL WITH THE TOP EDGE OF THE BOARD AT 78" A.F.F., STARTING FROM THE END OF THE LAST COOLER AND STOPPING 5'-0" FROM REAR WALL. 4. FASTEN THE 2X4 TO THE WALL WITH THE TOP EDGE OF THE BOARD AT 12" A.F.F., STARTING FROM THE END OF THE LAST COOLER AND STOPPING 5'-0" FROM REAR WALL. 5. PRE -DRILL PILOT HOLES IN ALL BOARDS PRIOR TO INSTALLATION TO PREVENT WOOD SPLITS. 6. SECURE THE 2X6 WITH THREE SELF -TAPPING SCREWS PER WALL STUD. MINIMUM SCREW SIZE IS 4"xa'. 7. FASTEN THE 2X4 WITH WITH ONE SELF -TAPPING SCREW PER WALL STUD. MINIMUM SCREW SIZE IS 4"x 4". 8. CAULK THE EDGES OF THE 2X6 AT THE TOP AND BOTTOM WHERE IT MEETS THE WALL PRIOR TO PAINTING. 9. PRIME AND PAINT BOTH BOARDS TO MATCH WALL COLOR. LINE OF FREEZER _ COOLERS BEYOND CONTRACTOR TO PROVIDE AND INSTALL 2x6 WHITE PINE GRADE 2 OR BETTER I __7;- J ----_ _._-__-... _.__ ..........._.._..__.._...._.._. __} I _._._.__._._.._....._.....-.-.-TT I~I I nii II I I gyp; pi j n; FIXTURE PPLIED A nl INSTALLE i I I p p' N ni BY DOLLA GENERAL I p II II II I i! IIMERCHANIRISING II p I I DEPARTMENT CONTRACTOR TO I I Ili p I I I I 4 p l I I INSTALL( 2 I I x WOOD p i I II I ;ii ®� FRAMIN,': TO ALLO II �i HORIZO TAL ANCH R - ao I I I I I! p I n` II II II (CONTRACTOR BOARD O RUN ip i II I !;i CONTIN JOUSLY PA n I TO ®i PEMB C LUMNS ®i PROVIDE D INSTAL n , i� 2x4 WHIT INE GRA I I p! 1 12 OR BET 1 R 1 IT- . .. . ............. _........... ___............ _.....__--___..._—......_._..__._.__ - .l .._....._._..—.. _ ._______.._.._...._..._.___ ... ....___.__._..........................._..._....Id — INTERIOR FACE OF PEMB FRAMING BEYOND ANCHOR BOARD: CONTRACTOR TO PROVIDE AND INSTALL 2x6 WHITE PINE GRADE 2 OR BETTER TOP OF FIXTURE TO BE AFFIXED TO DRIED PINE NAILER BY DOLLAR GENERAL MERCHANDISING DEPT FIXTURE SUPPLIED & INSTALLED BY DOLLAR GENERAL MERCHANDISING DEPT MTL LINER PANELS CONTRACTOR TO INSTALL VERTICAL 2X WOOD FRAMING SO THAT HORIZONTAL ANCHOR BOARDS RUN CONTINUOUSLY PAST PEMB COLUMNS ANCHOR BOARD: CONTRACTOR TO PROVIDE AND INSTALL 2x4 WHITE PINE GRADE 2 OR BETTER VERIFY ANCHOR BOARDS FINISHED FLOOR LOCATION WITH FIXTURE PLAN 2 ANCHOR BOARD DETAIL NTS 6 5 4 s A2 130'-8" 26-0" 26'-0" 26'-0" T-6" HOLD 17'-2" 1'-4" 1'-4" 23'-4" 1'4" 1'-4" 23'-4" V-4" l'-4" 2,-4„ 4" 64' MO 2 3 Y4 TYP AT Al Al 3 1 _ COLUMNS\ / \1-1/ Sim 2 6 1 26 I I i IH 6 EIFS BULLNOSE EIFS PILASTER (REF V-4" 1'4' EXTERIOR I - ELEVATIONS) i 5/8" EXTERIOR GRADE u COI GYPSUM BOARD SHEATHING ON METAL CD WALL PANELS - VINYL FACED R-13 BATT INSULATION + R-6.5 METAL BUILDING COLUMNS CONTINUOUS INSULATION SHALL BE STRAIGHT. TAPERED WITH VAPOR BARRIER (BY COLUMNS &INTERIOR COLUMNS PEMB). REQUIRE WRITTEN APPROVAL. "EWH-2" MAINTAIN INTERIOR CLEARANCE WATER HEATER ON 1/2" GYP BOARD OVER LINER OF 68'-0" BETWEEN FACE OF SHELF ABOVE MOP SINK — PANELS - REFER TO INTERIOR COLUMNS ON SALES FLOOR ELEVATIONS FOR LOCATIONS MOP SINK (BELOW) DETAIL @ COLUMN ABOVE BULLNOSE 3 (:: FAUCET THIS WALL ABOVE 4'-0" 3/4 = 1-0 T-0" OF 48" HIGH FRP DEFS ON 4" CMU 1'-4" 1'-4" ALUMINUM CORNER PILASTER (REF EXTERIO GUARDS 5 ELEVATIONS) COI 8'-0" WING WALL Sim DOORSTOP T-0" 00 4" 4" METAL BUILDING COLUMNS 8" CMU (REF EXTERIOR SHALL BE STRAIGHT. TAPERED ELEVATIONS) COLUMNS & INTERIOR REF. REQUIRE WRITTEN APPROVAL. 1/2" GYP BOARD OVER LINER STRUCTURAL MAINTAIN INTERIOR CLEARANCE PANELS - REFER TO INTERIOR COI OF 68'-0" BETWEEN FACE OF ELEVATIONS FOR LOCATIONS COLUMNS ON SALES FLOOR Cal COLUMN BELOW BULLNOSE 4DETAIL ABOVE 4'-0" 3/4" = V-0" 2 1 26'-0" 26'-8" 23'-4" 1'4" 1'-4" 23'-0" 2'4' 4„ 1 A3 A3a I I I I ( o l I I I I Il D D _ DER Stm RA L 2 [ 107 CLEAR FROM FACE OF IIOT-6" '-5" MINIMUM INSIDE CLEAR DIMENSION 12 I 104 15 - N ELECTRICAL PANEL----'\ ( ) - 1 i DOOR TACTILE - - SIGNAGE ' 6 104 6 ' _ _ I o - Ol — o 4 N 01 - 19 HA WAY 6 ao N 2 7 �? _ 7 01 '19 20 ; _ 10 5 __...........__._._. ' Al Al 24 24 10 24 _ 01 6 - SIM�� 22 22 22 CO ' GENDER t 5 v NEUTRAL - - , 22 'sm 105 C C< — —T ri / C6 — 24 — _ I - 2 0 IT A2 � N N WALL TYPES LEG END SEE SHEET Al 0 FOR ADDITIONAL NOTES AND DETAILS WALL TYPE (I.E. FULL HEIGHT) z in Oz &5w z2 wo 13 Q _ Wuu') L V �� U O_ w= z� z O1 1 49-7 1 /2" i I... " 111 1 1 l 65'-8 1/2" 5 3 01 Al P1 6' 0" 2'-6" SIM. O INTERIOR DIMENSION NOTE. - SALES AREA MINIMUM DIMENSIONS TO BE MAINTAINED SALES AREA 102 o% 21 25 21 oN w 25 01 21 N 01 i N 04 21 25 CV OT 01 9 N 20 3 1 5 l i 1 2811 115 " 9 11 f 7 11/1 1 15 14'-3" T-4" le 4'-9" le 14, le llie 11 2'-4" 26'-0" MO 1,_4„ 1'-4 6 ) ( 5 3 4 i Al Al �/OPP. 23'-4" V V 23'-0" 26-0" 1'-4' 1'-4" 26'-0" 1'-8" 130'-8" 4 4 3 A2 NOR 1 FLOOR PLAN Scale: 1/8" = 1'-0" 1 o A2 N N 23 5 w v LO 01 01 ' 21 / 16 / OFFICE 101 ' _ - O N N c— J >Q Q z > Q O N U OU w u- ���w SIM- 19 2 9'-2" - ' ' (V 0? LO — - _ ._._._.. / / �"— -- s ' — — ' TACTILE M E -- ----------- DOOR I ; SIGNA m 17 ' CD Q 2 1 I o sl rA 4== 00 i 14 15 5 17 i�i�� � 1 23'-8" V V 9'- 1/2" 13'-1112" „ 26'-0" 1'-4" 1'-4 26'-8" 10'-10 1/2" CMU AT 10'-8" AFF TO COLUMN LINE 2 - 2 REFER TO WALL SECTION MOP HOLDER 5'-0" OF 48" HIGH FRP 5 ENLARGED PLAN DETAIL SEE 4/P2 ALSO NTS FLOOR PLAN KEYED NOTES RECEIVING DOOR BUZZER (TORK MDL.#TA725 OR EQUAL) ❑2" DOOR SCOPE 2 (REF DOOR SCHEDULE SHEET A5) WEATHER STRIP & LOW PROFILE THRESHOLD (REF DOOR SCHEDULE SHEET A5) ElSTRIPE FLOOR AT RECEIVING DOOR AS INDICATED FOR DESIGNATED EGRESS PATH (PAINT YELLOW) AND DESIGNATE 3'-0" EMS PANEL CLEARANCE (PAINT RED) STRIPE FLOOR FOR DESIGNATED ADA EGRESS 4A PATH (PAINT YELLOW) 5 PROVIDE AND INSTALL WATER HEATER ABOVE THE MOP SINK (REF 5/A1 AND 3/P1) BEAUTY AND COSMETICS SHELVING AND EQUIPMENT. METAL LINER PANELS COORDINATE FULL HEIGHT PANELS W/ FURRING @ CMU WEST WALL FOR FLUSH FINISH ElCART AREA. REFER TO 5/A06 WALL OUTLETS FOR BANKS OF COOLERS AND ❑9 FREEZERS AND COSMETICS VALANCE. SEE ELECTRICAL FOR DETAILS. 10 CONCRETE SLAB ON VAPOR BARRIER (REF STRUCTURAL SHEET S2) 11 METAL BUILDING FRAME REFER TO NOTED WALL SECTION FOR ADDITIONAL INFORMATION ❑1/2" GYP BOARD OVER LINER PANELS W/ R-13 BATT 12 INSULATION. METAL LINER PANELS TO DECK ABOVE; GYPSUM BOARD TO RUN TO 10'-0" AFF, PAINTED. ROOF MOUNTED HVAC UNITS - COORDIANTE PAD 13 DIMENSIONS WITH HVAC UNITS (REF CIVIL PLAN AND SHEET M1) BROOM FINISH CONCRETE SIDEWALK - SLOPE 14 CONCRETE AWAY FROM BUILDING (TYP) - (COORDINATE WITH CIVIL PLANS). 1 5 EIFS PILASTER (REF EXTERIOR ELEVATIONS) H16 STOREFRONT SYSTEM (REF SHEETS A5) 17 LINE OF CANOPY ABOVE 18 A.D.A. COMPLIANT H.C. RAMP. (REF CIVIL PLANS) CART AND BUMPER GUARDS 4" A.F.F 19 MC CUE PART #9014 TRIMKIT) (REF 5/A6) 20 WALL HYDRANT (REF PLUMBING SHEET P1 FOR ADDITIONAL INFORMATION) 21 REFRIGERATION BY DOLLAR GENERAL 22 STEEL COLUMN. PAINT SW7005 PURE WHITE. WRAP STEEL COLUMN WITH TIGHT LOOP CARPET(BLACK) FROM BASE TO 48" A.F.F. 23 POWER POLE. COORDINATE FINAL LOCATION WITH ELECTRICAL DRAWINGS FLOOR ARE AT BASE OF COLUMN WITHIN THE 24 CONSTRUCTION JOINTS TO BE PAINTED BLACK MAGIC TINT ENDCAP COOLER/FREEZER TO BE HARDWIRED THROUGH WHITE SO CORD. GC TO LEAVE BOTTOM 25 HANGING AT 80" AFF. (REF. ELECTRICAL) CORD ANCHORED TO PURLINS ABOVE. COORDINATE LOCATION WITH FINAL DOLLAR GENERAL FIXTURE PLAN. BEAUTY STATION TO BE HARDWIRED THROUGH WHITE SO CORD. GC TO LEAVE BOTTOM HANGING AT 48" 25A AFF. (REF. ELECTRICAL) CORD ANCHORED TO PURLINS ABOVE. COORDINATE LOCATION WITH FINAL DOLLAR GENERAL FIXTURE PLAN. 26 PRE -FINISHED METAL DOWNSPOUTS (COORDINATE H SIZE AND LOCATIONS WITH PEMB AND CIVIL PLANS) ❑MC CUE RAILING IN FRONT OF ELECTRICAL PANELS 27 8'-0" LONG WITH TOP TWO RAILINGS AND NO MIDDLE POST. 8" SMOOTH -FACED CMU PAINTED (REFER TO EXTERIOR 28 FINISHES ON SHEET A2), ALIGN FACE OF BLOCK WITH STEEL GIRT. PROVIDE PROPER ANCHORAGE TO STRUCTURE. CONSULTANT: SEAL: JOHN BENEDICT POLSINELLI, AR96059 '4�. "01 THIS DRAWING SHALL NOT BE USED FOR CONSTRUCTION PURPOSES UNTIL THE SEAL AND SIGNATURE OF THE RESPONSIBLE REGISTRANT APPEARS ON THE DRAWING, AND PROPER PERMIT FORMS AND RELATED FEES ARE TRANSMITTED BY THE OWNER, OWNER'S AGENT OR CONTRACTOR TO THE AUTHORITY HAVING JURISDICTION. DATE ISSUED FOR REV 09/27/2018 PEMB COORDINATION 1 2/18/2018 PERMIT SUBMITTAL 01 /1 1 /2019 OWNER REVIEW 02/07/2019 BID SET 03/04/2019 ADDENDUM 01 1AN1 Project Manager Drawn L. LONG B. JACKSON Project Leader Checked L. LONG G. KARANFILOVSKI Date Dept Mgr Approval 08/07/2018 G. KARANFILOVSKI Client PALMETTO ZEPHYRHILLS-20th St, LLC P.O. BOX 1 61 5 THOMASVILLE, GA 31 792 Office: (229) 226-0682 Contact: John Tate Project DOLLAR GENERAL 38965 CR 54 Zephyrhills, FL 33542 (City of Zephyrhills) Store #: 20360 Drawing Title FLOOR PLAN DO NOT SCALE DRAWING Project No. Drawing No. .JCDT. 18.0233 Al _.. .. ,-. ._.-�s...�.�,..--�.._ .ya c.u.,.:,�, ..� :,. �. a a;;�•=iCvi,fiY- - uf_i. .. _i-f:.l L_ f!.0 w.AdLi a:­6lite* Q��L,H FINISH FLOOR = 0'-0" it EAST E L EVATI 0 N Scale: 1/8" = P-0" EXTERIOR FINISHES TAG MATERIAL MANUFACTURER COLOR / STYLE GENERAL REMARKS OEIFS WALL SYSTEM-01 REF PRODUCT APPROVAL ON COVER SHEET COLOR TO MATCH SW #7055 "ENDURING BRONZE" LIT 1.0- FINE OR APPROVED EQUAL OEIFS WALL SYSTEM-02 REF PRODUCT APPROVAL ON COVER SHEET COLOR TO MATCH SW #6149 "RELAXED KHAKI" LIT 1.0- FINE OR APPROVED EQUAL OEIFS (CORNICE) REF PRODUCT APPROVAL ON COVER SHEET COLOR TO MATCH SW #6385 "DOVER WHITE" LIT 1.0- FINE OR APPROVED EQUAL DO EIFS (ACCENT BANDING) REF PRODUCT APPROVAL ON COVER SHEET COLOR TO MATCH SW #6385 "DOVER WHITE" LIT 1.0- FINE OR APPROVED EQUAL ODEFS ON CMU REF PRODUCT APPROVAL ON COVER SHEET COLOR TO MATCH SW #7055 "ENDURING BRONZE" O8" SMOOTH FACE CMU REF PRODUCT APPROVAL ON COVER SHEET COLOR TO MATCH SW #6149 "RELAXED KHAKI" OGUTTERS & DOWN SPOUTS PEMB MANUFACTURER LIGHT STONE OSTANDARD METAL ROOF PANELS PEMB MANUFACTURER GALVALUME PBR ROOF PANELS W/ ATLAS ULTIMATE FASTNER JO REAR BUILDING PARAPET WALL PEMB MANUFACTURER LIGHT STONE OSTOREFRONT SYSTEM REF PRODUCT APPROVAL ON COVER SHEET DARK BRONZE OPREFINISHED METAL COPING @ PARAPET REF PRODUCT APPROVAL ON COVER SHEET DARK BRONZE ALUMINUM FRAME M HOLLOW METAL DOOR / FRAME REF PRODUCT APPROVAL ON COVER SHEET COLOR TO MATCH SW #7055 "ENDURING BRONZE" LIT 1.0- FINE OR APPROVED EQUAL T/O PARAPET = 19'-2" AFF o - 19 EAVE STRUT in 14'-4" AFF eo (V _F 00 T � - - 1 v r FINISH FLOOR ``' = n,_n, EXTERIOR BUILDING NOTE: ALL EXTERIOR SIGNAGE SHALL BE SUBMITTED UNDER SEPARATE PERMIT NORTH ELEVATION SOUTH ELEVATION Scale: 1/8" = V-0" Scale: 1/8" = V-0" D C B A Al L L C W,.. I KEYED NOTES GC SHALL COORDINATE THE EXTERIOR SIGN WITH DOLLAR GENERAL CORP. GC TO PROVIDE ADEQUATE BLOCKING AS REQUIRED BY SIGN MANUFACTURER TO SUPPORT SIGN WEIGHT (MAX 1,400 LBS). GC TO PROVIDE CIRCUIT AS NOTED ON ELECTRICAL PLAN. SIGN TO BE PROVIDED AND INSTALLED BY DOLLAR GENERAL CORP. INSTALL BUILDING SIGN CENTERED ON FRONT ELEVATION. ROOFTOP EQUIPMENT SCREENS BY CITYSCAPES OR EQUAL, COLOR: PUTTY. FLOOD LIGHT. REFER TO ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION. LINE OF PRE -FINISHED METAL ROOF BEYOND 141 (REF EXTERIOR FINISH SCHEDULE THIS SHEET) (4) 1/2" DIA X 6" LG STAINLESS STEEL EYE BOLTS (CLOSED) �5 WITH 1" DIA OPENING - DRILL AND EPDXY INTO BLOCK WALL EXTERIOR RECEPTACLE. RE: ELECTRICAL �7 1/2" EIFS V-GROOVE (TYP) WALL PACK. REFER TO ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION. 1:fl DOOR BUZZER 10 MECHANICAL VENT REFER TO MECHANICAL DRAWINGS. t t PLUMBING VENT - REFER TO PLUMBING DRAWINGS. 12 WALL HYDRANT. RE: PLUMBING ROOF MOUNTED HVAC UNITS ON PRE FABRICATED ROOF 13 CURB (REF SHEET M1) 14 OUTSIDE AIR TEMP. SENSOR MOUNTED OVER RECEIVING DOORS @ 8'-0" A.F.F. 15 EIFS EXPANSION JOINT 7 :....... A . 7" 7 I A � � N },•; B B.. B D. D - D D D : A. A :...: _ D r E ) I I `--( E WEST ELEVATION Scale: 1/8" = V-0" �!09 � m Oil oil T/O = ( FINISH FL = n,-n" PEMB MANUFACTURER SHALL PROVIDE ALL METAL FRAMING, REAR PANELS, CRICKETS, AND REQUIRED FLASHING FOR ANY AND ALL PARTS OF THE RAISED PARAPET AND MASONRY PILASTERS ABOVE THE ROOF LINE - TYP CONSULTANT: SEAL: JOHN BENEDICT POLSINELLI, AR96059 THIS DRAWING SHALL NOT BE USED FOR CONSTRUCTION PURPOSES UNTIL THE SEAL AND SIGNATURE OF THE RESPONSIBLE REGISTRANT APPEARS ON THE DRAWING, AND PROPER PERMIT FORMS AND RELATED FEES ARE TRANSMITTED BY THE OWNER, OWNER'S AGENT OR CONTRACTOR TO THE AUTHORITY HAVING JURISDICTION. DATE ISSUED FOR REV 09/27/201 8 PEMB COORDINATION 1 2/1 8/201 8 PERMIT SUBMITTAL 01 /1 1 /2019 OWNER REVIEW 02/07/2019 BID SET 03/04/2019 ADDENDUM 01 01 Project Manager Drawn L. LONG B. JACKSON Project Leader Checked L. LONG G. KARANFILOVSKI Date Dept Mgr Approval 08/07/201 8 G. KARANFILOVSKI Client PALMETTO ZEPHYRHILLS-20th St, LLC P.O. BOX 1615 THOMASVILLE, GA 31 792 Office: (229) 226-0682 Contact: John Tate Project DOLLAR GENERAL 38965 CR 54 Zephyrhills, FL 33542 (City of Zephyrhills) Store #: 20360 Drawing Title EXTERIOR ELEVATIONS DO NOT SCALE DRAWING Project No. Drawing No. .JCDT.18.0233 A2 ROOM SCHEDULE FLOOR BASE A WALL B WALL C WALL D WALL CEILING CEILING MATERIAL FINISH MATERIAL FINISH MATERIAL FINISH MATERIAL FINISH MATERIAL FINISH MATERIAL FINISH NO ROOM NAME MATERIAL FINISH REMARKS CONCRETE CONCRETE 4" RUBBER / BLACK GYPSUM BOARD SHERWIN WILLIAMS - , GYPSUM BOARD SHERWIN WILLIAMS - GYPSUM BOARD SHERWIN WILLIAMS - GYPSUM BOARD SHERWIN WILLIAMS - 2'X4' ACOUSTICAL WHITE 100 BREAK RM FLOOR SEALED WITH SEALER VINYL BASE TO 10'-0" AFF ON PRO -MAR LATEX TO 10'-0" AFF, SW7005-PURE WHITE, TO 10'-0" AFF SW7005-PURE WHITE, TO 10'-0" AFF SW7005-PURE WHITE, CEILING 8'-0" A.F.F. (STEPS 1-3) MTL STUDS TO SEMI -GLOSS. WHITE METAL PRO -MAR LATEX PRO -MAR LATEX PRO -MAR LATEX UNDERSIDE OF LINER PANELS SEMI -GLOSS. SEMI -GLOSS. SEMI -GLOSS. DECK ABOVE. ABOVE CONCRETE CONCRETE 4" RUBBER/ BLACK GYPSUM BOARD SHERWIN WILLIAMS - GYPSUM BOARD SHERWIN WILLIAMS - GYPSUM BOARD SHERWIN WILLIAMS - GYPSUM BOARD SHERWIN WILLIAMS - 2'X4' ACOUSTICAL WHITE 101 OFFICE FLOOR SEALED WITH SEALER VINYL BASE TO 10'-0" AFF SW7005-PURE WHITE, TO 10'-0" AFF, SW7005-PURE WHITE, TO 10'-0" AFF SW7005-PURE WHITE, TO 10'-0" AFF SW7005-PURE WHITE, CEILING 8'-0" A.F.F. (STEPS 1-3) PRO -MAR LATEX WHITE METAL PRO -MAR LATEX PRO -MAR LATEX PRO -MAR LATEX SEMI -GLOSS. LINER PANELS SEMI -GLOSS. SEMI -GLOSS. SEMI -GLOSS. ABOVE CONCRETE POLISHED 4" RUBBER/ BLACK GYP BOARD TO SEE 1/A4 FOR FINISH GYPSUM BOARD SEE 1/A4 FOR FINISH GYP BOARD TO SEE 1/A4 FOR FINISH GYPSUM BOARD SEE 1/A4 FOR FINISH EXPOSED TO EXPOSED TO REFER TO FINISH 102 SALES AREA FLOOR POLISHED CONCRETE VINYL BASE 10'-0" A.F.F. ON PAINT LOCATIONS PER HEIGHT PAINT LOCATIONS 10'-0" A.F.F. ON PAINT LOCATIONS TO ROOF DECK PAINT LOCATIONS STRUCTURE STRUCTURE PLAN 1/A4 FOR WITH SEALER WHITE METAL NOTED ON WALL WHITE METAL ABOVE ABOVE ADDITIONAL (STEPS 1-8) LINER PANELS ELEVATIONS LINER PANELS NOTES CONCRETE CONCRETE N/A N/A METAL LINER LIGHT STONE. GYPSUM BOARD LIGHT STONE METAL LINER TAPED. PAINTED AS METAL LINER TAPED. PAINTED AS EXPOSED TO N/A 103 RECEIVING AREA FLOOR SEALED WITH SEALER PANEL ABOVE CMU PAINT CMU SW#6149 TO U/S OF DECK PANEL TO 8'-0" AFF REQUIRED BY CODE. PANEL TO 8'-0" AFF REQUIRED BY CODE. STRUCTURE (STEPS 1-3) ABOVE MTL. LINER PANEL TO MTL. LINER PANEL TO ABOVE DECK AS ALTERNATE. DECK AS ALTERNATE. CONCRETE SHERWIN WILLIAMS 8 -0 HIGH FIBERGLASS GYPSUM BOARD 8 -0 HIGH FIBERGLASS GYPSUM BOARD 8 -0 HIGH FIBERGLASS GYPSUM BOARD 8 -0 HIGH FIBERGLASS 2 X 4 WHITE 104 GENDER FLOOR SEALED ACRYLIC SILICONE RUBBER/ I BLACK GYPSUM BOARD REINFORCED PANEL - TO 8-4' AFF REINFORCED PANEL - TO 8'-0" AFF REINFORCED PANEL - TO 8'-0" AFF REINFORCED PANEL - GYP BD OR ACT NEUTRAL SILK CHOCOLATE V VINYL BASE TO 8'-0" AFF "WHITE" "WHITE" "WHITE" "WHITE" CEILING @ HC-117 (STEPS 1-3) 8'-0" A.F.F. CONCRETE SHERWIN WILLIAMS 8 -0�� HIGH FIBERGLASS GYPSUM BOARD 8' -0�� HIGH FIBERGLASS GYPSUM BOARD a 8 -0�� HIGH FIBERGLASS GYPSUM BOARD 8' -0�� HIGH FIBERGLASS 2 X 4 WHITE 105 GENDER FLOOR SEALED ACRYLIC SILICONE RUBBER/ BLACK GYPSUM BOARD REINFORCED PANEL - TO 8'-0" AFF REINFORCED PANEL - TO 8'-0" AFF REINFORCED PANEL - TO 8'-0" AFF REINFORCED PANEL - GYP BD OR ACT NEUTRAL SILK CHOCOLATE V VINYL BASE V TO 8'-0" AFF "WHITE" "WHITE" "WHITE" "WHITE" CEILING @ HC-117 (STEPS 1-3) 8'-0" A.F.F. CONCRETE POLISHED SHERWIN WILLIAMS - GYPSUM BOARD SHERWIN WILLIAMS - GYPSUM BOARD SHERWIN WILLIAMS - GYPSUM BOARD SHERWIN WILLIAMS - 2 X 4 ACOUSTICAL WHITE 107 HALLWAY FLOOR SEALED CONCRETE WITH 4" RUBBER/ BLACK GYPSUM BOARD SW6991 BLACK MAGIC, TO 8'-0" AFF SW6991 BLACK MAGIC, TO 8'-0" AFF SW6991 BLACK MAGIC, TO 8'-0" A.F.F. ON SW7005 PURE WHITE, CEILING @ 8'-0" SEALER (STEPS 1-9) VINYL BASE TO 8-0 AFF PRO -MAR LATEX PRO -MAR LATEX PRO -MAR LATEX BULKHEAD PRO -MAR LATEX SEMI- A.F.F. SEMI -GLOSS TO 48" SEMI -GLOSS TO 48" SEMI -GLOSS TO 48" GLOSS ABOVE 48" AFF. SHERWIN AFF. AFF. AFF. WILLIAMS - SW7005 SHERWIN WILLIAMS - SHERWIN WILLIAMS - PURE WHITE, SW7005 PURE WHITE, SW7005 PURE WHITE, PRO -MAR LATEX SEMI- PRO -MAR LATEX SEMI- PRO -MAR LATEX SEMI- GLOSS ABOVE 48" GLOSS ABOVE 48" GLOSS ABOVE 48" AFF. I AFF. 1AFF. NOTE: ALL ALL PAINTED WALLS TO BE PRIMED FIRST, THEN PAINTED INTERIOR PAINT SCHEME: DOLLAR GENERAL TRADITIONAL (E) NOTE: ALL DOORS & DOOR FRAMES INSIDE SALES AREA (EXCLUDING MAIN STOREFRONT ENTRANCE & RELATED GLAZING) SHALL BE PAINTED SW 6991 "BLACK MAGIC" FLOOR FINISH LOCATION PLAN Scale: 1/16" = V-0" PRE -FINISHED METAL LINER PANELS TO UNDERSIDE OF DECK ABOVE I --------IT - O / / Z / / O - ff 0 PEMB FRAMING, PAINT TO MATCH ADJACENT WALL— / ELEVATION 'A' W O p p O ry F- J m O O 0 TO 48" A. F. F. P2 26'-8" ELEVATION 'B' PRE -FINISHED METAL LINER PANELS TO UNDERSIDE OF DECK ABOVE A O O r ry - - - - - - - - - - Pi PRE -FINISHED METAL LINER PANELS PEMB FRAMING, PAINT TO pl TO UNDERSIDE OF DECK ABOVE MATCH ADJACENT WALL P2 i / , /, / / / ,� J f f ,� / / / / / / 1 1 / / / / / / / / / :' ! f / / / / / / / .y / f / / / / / / / f J ,` , / / / / / / f / / / / / / / / / / ! :' f / / / / / / / / ,� r f / / / / / / / / ,/ / / / / / / / / / / / / / / / / f / / .•' / / / / / / / / ' ,' r / / / / / / / i ' f / / / ® Oi zo TRANSFER GRILLE - REF. ELEVATION 'C' MECHANICAL DRAWINGS— \ 25'-0" H-/ 10'-0" WALL PAINT LEGEND p1 SW6910 "DAISY" p2 SW6991 "BLACK MAGIC" P3 SW7005 "PURE WHITE" P4 EXPOSED LINER PANEL P5 DENOTES GYPSUM BOARD, TAPED AND MUDDED ONLY NOTE: PAINT EXPOSED STRUCTURE SW7005 PURE WHITE CONSULTANT: SEAL: JOHN BENEDICT POLSINELLI, AR96059 THIS DRAWING SHALL NOT BE USED FOR CONSTRUCTION PURPOSES UNTIL THE SEAL AND SIGNATURE OF THE RESPONSIBLE REGISTRANT APPEARS ON THE DRAWING, AND PROPER PERMIT FORMS AND RELATED FEES ARE TRANSMITTED BY THE OWNER, OWNER'S AGENT OR CONTRACTOR TO THE AUTHORITY HAVING JURISDICTION. DATE ISSUED FOR REV 09/27/2018 PEMB COORDINATION 1 2/1 8/201 8 PERMIT SUBMITTAL 01 /1 1 /201 9 OWNER REVIEW 02/07/2019 BID SET 03/04/201 9 ADDENDUM 01 01 Project Manager Drawn L. LONG B. JACKSON Project Leader Checked L. LONG G. KARANFILOVSKI Date Dept Mgr Approval 08/07/2018 G. KARANFILOVSKI Client PALMETTO ZEPHYRHILLS-20th St, LLC P.O. BOX 1615 THOMASVILLE, GA 31 792 Office: (229) 226-0682 Contact: John Tate Project DOLLAR GENERAL 38965 CR 54 Zephyrhills, FL 33542 (City of Zephyrhills) Store #: 20360 Drawing Title ROOM FINISH SCHEDULE AND SALES FLOOR ELEVATIONS DO NOT SCALE DRAWING Project No. Drawing No. .JCDT.18.0233 A4 IVES WALL MOUNTED DOOR STOP o Q McCUE TRIM KIT W WITH BUMPER U GUARDS AND CART STOP CD (REF DETAIL 5 d THIS SHEET)!-) IVES WALL MOUNTED DOOR STOP 00 A4 v LO 102 SALES AREA 6'-11 Z" i �GENDE / NEUTQ / 104 1 \ I 7'-4%2" ---- — _ _ X 4" TYP 104 6-6" 10 ;A6 HALLWE7 L — 107 — 105 i l i i — — 7'-4%z11 — J NEUTR L g \\ 105 // I I T-4%2" 00 100 ROOM M BREAK q 100 M IVES WALL - MOUNTED DOOR STOP 101 4'-0%2" 3'-0 0 4 101 OFFICE McCUE TRIM KIT o WITH BUMPER GUARDS AND 4y2 CART STOP 7'-8%2" (REF DETAIL 5 0 THIS SHEET) LO LOW WALL PARTITION ------------ co 0 '7a Z) 00U) �° °' O - CA ~ CD O 12"X12" LOUVERED VENT H FOR HUB DRAIN ACCESS - MAINTAIN REQUIRED HEIGHTS AND CLEARANCES FOR DRINKING FOUNTAINS 2" D ACCESS PANEL DETAIL 1 O Scale: 1/2"=1-0" 40" O REAR WALI. 1/2" GYPSUM BOARD ON 2-1/2" METAL STUDS @ (D 16" O.C. THIS WALL 1/2" GYPSUM BOARD ON 3-5/8" METAL - STUDS @ 16" O.C. co� � m EO FINISHED `Y' O N FLOOR ~ SOAP GRAB BAR DISPENSER N `V ADA DRINKING FOUNTAIN (REF PLUMBING) WALL HYDRANT 9 MOUNTING HEIGHTS (REF PLUMBING) Scale: 1/4" = V-0" 1/2" GYPSUM BOARD ON 3-5/8" METAL STUDS @ 16" O.C. 8" HORIZONTAL BUMPER TRIMMED TO 8" SHORTER THAN THE SPACE WHERE 1/2" GYPSUM APPLIED, CENTER IN SPACE. BOARD ON 2-1/2" METAL STUDS @ 48" HIGH WALL WITH 1x WOOD CAP 16" O.C. PAINTED TO MATCH C McCUE TRIM KIT INCLUDES BUMPER GUARDS AND CART`90 STOP. +' •09d 0 ! dli­ 0 FD (V CONTRACTOR SHALL LEAVE AN AS -BUILT SET OF CONSTRUCTION PLANS, ROLLED UP AND PLACED INSIDE 4"xW" PVC PIPE MOUNTED HORIZONTALLY ON THE WALL ABOVE THE DOOR IVES WALL MOUNTED DOOR STOP 0 CD 00 v 6 A3a 1 A NORTH RESTROOM/OFFICE/BREAK ROOM PLAN Scale: 1/4" = V-0" 36" CORNER GUARD 0 co Scale: NTS z 00 O O co Q 1 !3� GENDER INTERNATIONAL Tp SYMBOL OF NEU 1 R ACCESSIBILITY AI HC WALL SIGN SIGNAGE SHALL COMPLY WITH ANSI A117.1 2009 SIGNS SHALL HAVE A NON -GLARE FINISH. CHARACTERS AND SYMBOLS SHALL CONTRAST WITH THEIR BACKGROUND o FINISHED co ® FLOOR r-- -- HC RESTROOM SIGN LOCATED ON THE WALL ADJACENT TO THE LATCH .......... "" i Y SIDE OF THE DOOR OR ON THE NEAREST ADJACENT WALL, PREFERABLY ON THE RIGHT O N Q ADA cn " , o N Z _; SE "° M M M o ACCESSIBILITY SIGNAGE C, NOTE #2 O EWC RAIL ELEV TOILET AND MIRROR UNIT BABY HAND DRYERCOAT HOOK TOILET PAPER CHANGING HOLDER STATION NEW TACTILE EXIT SIGNAGE iorrrn T!1 Tuicc+urrT ran nrTn II FLOOR MOUNTED, STEELTUBULAR CART STOP 0 ro y-8" HORIZONTAL BUMPER ON EXTERIOR WALL, TRIMMED TO 8" SHORTER THAN THE SPACE WHERE APPLIED, CENTER IN SPACE. (SHOWN SCREENED FOR CLARITY) 6 TACTILE EXIT SIG NAG E Scale. 1/2 - 1-0 4'-0" MIN 4'-0" MIN ---� - CLEAR FLOOR SPACE FOR o ° Z LAVATORY FIXTURE - 0) — — — — — — — Z� 1'" 3 ADA CLEARANCES Scale: NTS MIRROR W/ FRAME 1 '-6" oil z Q� co _ = o O LO _1 N CV 10" x 6" LOUVERED VENT, (1) IN EACH RESTROOM 4" BASE 2 RESTROOM ELEVATIONS Scale: NTS CLEAR FLOOR SPACE I I I --------- 0 0 co FIN. 3/8" MIN TO 1/2" MAX CONTRACTOR TO VERIFY THAT EXISTING SIGNAGE COMPLIES WITH THIS DETAIL. IF SIGNAGE DOES NOT COMPLY OR DOES NOT EXIST THEN PROVIDE NEW PER DETAILS & AS REQUIRED BY LOCAL AUTHORITIES. LR. TACTILE CHARACTERS TO BE FONT 'SANS SERIF' (ALLUPPERCASE) WITH MAX. HEIGHT OF 2", WIDTH TO HEIGHT RATIO BTWN 3:5 AND 1:1 AND STROKE WIDTH TO HEIGHT RATIO BTWN 1:5 AND 1:10. CHARACTERS SHALL BE RAISED 1/32" FROM SIGN SURFACE. SIGNAGE BACKGROUND TO BE CONTRASTING COLOR TO TEXT GRADE 2 BRAILLE EITHER CENTERED OR JUSTIFIED LEFT 3/8" TO 1/2" MAX BELOW TACTILE CHARACTERS. SEE ADA ACCESSIBILITY GUIDELINES FOR BRAILLE SPECIFICATIONS. TACTILE EXIT SIGNAGE DETAIL R Scale: 6" = V-0" 34" A. F. F. 4 GRAB BAR DETAIL Scale: NTS MIRROR SOAP DISPENSER PAPER TOWEL HOLDER U INSULATE AROUND PIPES MIN 1'-6 ill 2 17" MIN. 4" BASE BASS SECURITY SERVICES, INC. 888-774-3400 EXT. 2024 BASS SECURITY PARTS B155 BOBRICK 24 OZ. SOAP DISPENSER B2740 BOBRICK DOUBLE TOILET TISSUE DISPENSER B253 BOBRICK PAPER TOWEL DISPENSER 54-US32D BURNS PUSH PLATE 5410-32D-26D-GRIP BURNS PULL PLATE DDH-2250 ** DETEX DOUBLE DOOR HOLDER DS/1000MB DOOR SCOPE (FOR RECEIVING EXIT DOOR) 608Z 8" DOOR HOLDER 770SAV-3FT 3 FT DOOR SWEEP 770SAV-4FT 4 FT DOOR SWEEP W1 0 1 S-DAN E-626 FALCON PASSAGE LEVERSET W581 PD-DANE-626 FALCON STOREROOM LEVERSET A-24x36 GAMCO 24" x 36" ANGLE FRAME MIRROR 150Sx36 GAMCO 1 1/2" X 36" GRAB BAR 150Sx42 GAMCO 1 1/2" X 42" GRAB BAR 150Sx18 GAMCO 1 1/2" X 18" GRAB BAR MS-1 GAMCO MOP HOLDER 5400 HAGER DOOR CLOSER 7015SC8-26D * ILCO RIM CYLINDER 402-1/2B-26D IVES WALL STOP 452B26D-4 IVES 4" DOOR HOLDER 8400-S32D-8X34 IVES KICK PLATE NATIONAL GUARD HD THRESHOLD 425 HD - 6 FT. (FOR RECEIVING EXIT DOOR) TA331OPC TACO DOOR VIEWER 2670-28 VON DUPRIN GUARD-X EXIT ALARM LOCK 2609 ** VON DUPRIN GUARD-X DOUBLE DOOR STRIKE 892SAV-84INCH WEATHERSTRIPPING * MUST HAVE ONE RIM PER EXIT DEVICE. ** MUST HAVE DOUBLE DOOR STRIKE AND TWO DOUBLE DOOR HOLDERS FOR ALL DOUBLE EXIT DOORS. REST ROOMS: 1. RESTROOMS SHALL COMPLY WITH ALL BUILDING (FEDERAL, STATE, AND LOCAL) FIRE, AND HEALTH DEPARTMENT CODES AND ADA REQUIREMENT. 2. PROVIDE AND INSTALL 2'x3' MIRROR (OR LARGER IF REQUIRED BY CODE). 3. CONTRACTOR TO INSTALL SOAP DISPENSERS, TOILET PAPER HOLDERS, DOOR CLOSERS, DOOR HOLDERS, EXHAUST FANS, AND ALL BASS SECURITY PARTS IN BOTH RESTROOMS. FAUCETS SHALL BE OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE TIGHT GRASPING, PINCHING OR TWISTING OF THE WRIST. 4. INSTALL INSULATION ON ALL EXPOSED PIPES BELOW SINKS AND LAVATORIES TO COMPLY WITH STATE AND LOCAL CODES. 5. SEE FIXTURE MOUNTING HEIGHTS FOR ALL TOILET ROOM ACCESSORIES. VERIFY HEIGHT WITH LOCAL CODES. 6. CONTRACTOR TO VERIFY LOCATION OF OWNER SUPPLIED TOILET ACCESSORIES WITH ARCHITECT PRIOR TO INSTALLATION. 7. 6"x9" ACCESSIBLE TOILET ROOM SIGNAGE TO BE WHITE TEXT AND SYMBOLS ON BLUE BACKGROUND, TYP. VERIFY REQUIREMENTS WITH LOCAL CODES. 8. WHERE WASTE RECEPTACLES, DISPENSERS AND OTHER EQUIPMENT WITH CONTROLS ARE PROVIDED, AT LEAST ONE OF EACH IN EACH TOILET ROOMS SHALL BE LOCATED ON AN ACCESSIBLE ROUTE WITH ALL OPERABLE PARTS WITHIN 48" FROM THE FINISHED FLOOR. 18" VERTICAL GRAB BAR PER CODE STAINLESS STL. GRAB BAR 2 ROLL TOILET TISSUE HOLDER IFI MIME 54 MIN. 42 MIN. 39"-41" 12 d M M CONSULTANT: SEAL: JOHN BENEDICT POLSINELLI, AR96059 THIS DRAWING SHALL NOT BE USED FOR CONSTRUCTION PURPOSES UNTIL THE SEAL AND SIGNATURE OF THE RESPONSIBLE REGISTRANT APPEARS ON THE DRAWING, AND PROPER PERMIT FORMS AND RELATED FEES ARE TRANSMITTED BY THE OWNER, OWNER'S AGENT OR CONTRACTOR TO THE AUTHORITY HAVING JURISDICTION. DATE ISSUED FOR REV 09/27/201 8 PEMB COORDINATION 1 2/1 8/201 8 PERMIT SUBMITTAL 01 /1 1 /2019 OWNER REVIEW 02/07/201 9 BID SET 03/04/2019 ADDENDUM 01 01 Project Manager Drawn L. LONG B. JACKSON Project Leader Checked L. LONG G. KARANFILOVSKI Date Dept Mgr Approval 08/07/2018 G. KARANFILOVSKI Client PALMETTO ZEPHYRHILLS-20th St, LLC P.O. BOX 1615 THOMASVILLE, GA 31792 Office: (229) 226-0682 Contact: John Tate Project DOLLAR GENERAL 38965 CR 54 Zephyrhills, FL 33542 (City of Zephyrhills) Store #: 20360 Drawing Title ENLARGED PLANS AND TOILET ROOMS DO NOT SCALE DRAWING Project No. Drawing No. ,JCDT.18.0233 A6 1" CONDUIT EMS PANEL BELOW — RECEIVING AREA 103 rAT'I UNISTRUT 10' LONG TERED ON ENDCAP .F.F. ON THREADED CLOSE TO BACK AS NISTRUT MOUNTED FLAT SIDE DOWN. CABLE TRAY NOTE: GC SHALL PROVIDE J AND INSTALL WHITE CABLE TRAY LINER 116-2 1 /2" SALES AREA 102 eo M N 15-8 BUNDLE ALL uORES AND GRAPHIC UNISTRUT 10' LONG ROUTE O CABLE o TO BE CENTERED ON ENDCAP TRAY AT 1V-0"A.F.F. ON THREADED 2'-6" TEE. TYP. �01 ROD. AS CLOSE O BACK AS CA 3LE TRAY POSSIBLE. UNISTRUTMOUNTED C T TO FIT FLAT SIDE DOWN. **PRE -PUNCHED 1 1/4" h� GALVANIZED ANGLES ARE p APPROVED EQUAL TO UNI-STRUT 2 CABLE TRAY PLAN Scale: NTS GRAPHIC UNISTRUT 10' LONG TO BE CENTERED ON AUTOMATED DOORS AT 1 T-0" A.F.F. ON THREADED OD. UNISTRUT MOUNTED FLAT SIDE DOWN. N Un N a �o 4' n 3 5/8" 20 GA. METAL STUD TO 1/2" MIN GYP STRUCTURE ABOVE BD TO DECK ABOVE C 1 BOX HEADER: I 2 X 4 A.C.T. CLG� _ (2) 6" 20 GA. METAL @ 8'-0" A.F.F. STUDS W/ 3 5/8" TRACK TOP AND 5/8" GYPSUM BOARD BOTTOM. TO 6" ABOVE FINISHED CEILING B.O. BULKHEADjk @ T-0" A.F.F. NOTE: IF A GYPSUM BOARD CEILING IS INSTALLED IN THE HALLWAY AN ACCESS PANEL MUST BE INSTALLED FOR ACCESS TO THE WATER HEATER. (MINIMUM 20"x30") SECTION AT SOFFIT REFLECTED CEILING PLAN Scale: 1" = V-0" 3/32" 7x7 AIRCRAFT CABLE. INSTALL HANGER CABLES USING ALL ATTACHMENTS DEVICES AS SPECIFIED BY WIRE MANUFACTURER. TOP OF LIGHT FIXTURE MOUNTED @ 1 V-0" A.F.F., MOUNT WITH AIRCRAFT CABLE TO UNISTRUT, UNISTRUT ATTACHED TO UNDERSIDE OF PURLIN. - 3 LIGHT ATTACHMENT DETAIL Scale. 1 1/2 = 1-0 Scale: 1/8" = V-0" TOP OF PEMB PURLIN (TYP) ROSS RUNNERS 10. 12 ga VERTICAL IANGERS IIN. OF THREE URNS IAIN RUNNER SUSPENDED GRID DETAIL GENDER NEUTRAL T @ 8'-0" A.F.F. NTERED IN ROOM 1. — . - - GENDER NEUTRAL OPEN TO ABOVE CENTER LIGHT IP ROOM OPEN TO ABOVE CENTER LIGHT II ROOM METAL PANEL CEILING (BY P a 10'-0" A. F. F. BREAKROOM Scale: 1" = V-0" LEGEND PANEL/CIRCUIT NO. A/12 LIGHT FIXTURE TYPE A NIGHT LIGHT CIRCUIT A NL LIGHT FIXTURE TYPE B LIGHT FIXTURE TYPE C LIGHT FIXTURE TYPE D SUSPENDED CEILING GRID & ACOUSTICAL CEILING TILE EMERGENCY LIGHT W/BATTER BACKUP K LIGHT EXIT SIGN W/ BATTERY BACKUP EXIT N WALL PACK J BI-DIRECTIONAL SECURITY LIGHTING SUPPLY DIFFUSER RETURN DIFFUSER CONSULTANT: SEAL: JOHN BENEDICT POLSINELLI, AR96059 THIS DRAWING SHALL NOT BE USED FOR CONSTRUCTION PURPOSES UNTIL THE SEAL AND SIGNATURE OF THE RESPONSIBLE REGISTRANT APPEARS ON THE DRAWING, AND PROPER PERMIT FORMS AND RELATED FEES ARE TRANSMITTED BY THE OWNER, OWNER'S AGENT OR CONTRACTOR TO THE AUTHORITY HAVING JURISDICTION. DATE ISSUED FOR REV 09/27/201 8 PEMB COORDINATION 1 2/1 8/201 8 PERMIT SUBMITTAL 01/11/2019 OWNER REVIEW 02/07/2019 BID SET 03/04/2019 ADDENDUM 01 01 Project Manager Drawn L. LONG B. JACKSON Project Leader Checked L. LONG G. KARANFILOVSKI Date Dept Mgr Approval 08/07/2018 G. KARANFILOVSKI Client PALMETTO ZEPHYRHILLS-20th St, LLC P.O. BOX 1615 THOMASVILLE, GA 31 792 Office: (229) 226-0682 Contact: John Tate Project DOLLAR GENERAL 38965 CR 54 Zephyrhills, FL 33542 (City of Zephyrhills) Store #: 20360 Drawing Title REFLECTED CEILING PLAN DO NOT SCALE DRAWING Project No. Drawing No. ,JCDT.18.0233 A9 I NORTH 1 HVAC LAYOUT Scale. 1/8 — 1 -0 SUPPLY (TYP. 2) TO DROP DIFFUSER GENERAL NOTES 1. GENERAL NOTES ARE APPLICABLE TO ALL HVAC DRAWINGS. 2. PERFORM WORK IN ACCORDANCE WITH THE LATEST EDITIONS, REVISIONS, AMENDMENTS, OR SUPPLEMENTS OF APPLICABLE STATUTES, ORDINANCES, CODES OR REGULATIONS OF FEDERAL, STATE, AND LOCAL AUTHORITIES HAVING JURISDICTION IN EFFECT ON THE DATE BIDS ARE RECEIVED. 3. WHERE APPROVED STANDARDS HAVE BEEN ESTABLISHED BY OSHA, UNDERWRITERS LABORATORIES, AMERICAN CODES, ASA, ASHRAE, ARI, NEC, STATE FIRE INSURANCE REGULATION BODY, NFPA OR OTHERS. 4. THESE STANDARDS SHALL BE FOLLOWED WHETHER OR NOT INDICATED ON THE DRAWING AND SPECIFICATIONS. 5. ALL DUCT TO BE OF 2" PRESSURE CLASS, UNLESS NOTED OTHERWISE. 6. LIGHT FIXTURE LOCATIONS TAKE PRECEDENCE OVER DIFFUSER AND GRILLE LOCATIONS. LOCATE DIFFUSERS AND GRILLES TO ACCOMMODATE LIGHTING LAYOUT. 7. PROVIDE TURNING VANES IN SUPPLY DUCT ELBOWS. PROVIDE TURNING VANES IN RETURN AND EXHAUST ELBOWS ONLY WHERE INDICATED ON PLANS. 8. DUCT SIZES SHOWN ARE NET FREE AREA. 9. PROVIDE FLEXIBLE DUCT CONNECTION BETWEEN AIR CONDITIONING UNIT AND DUCTWORK. 10, WHERE SINGLE SUPPLY DUCTS SPLIT INTO TWO DUCTS MAINTAIN EACH BRANCH DUCT SIZE THROUGH SPUTTER FITTING AND PROVIDE SINGLE TRANSITION ON UPSTREAM SIDE OF SPUTTER FITTING. 11. DUCT DETECTORS SHALL BE ACCESSIBLE FOR CLEANING AND MOUNTED IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTION. ACCESS DOORS AND/OR PANELS SHALL BE PROVIDED IN ACCORDANCE WITH NFPA 90A. THE LOCATION OF ALL DETECTORS IN AIR DUCT SYSTEMS SHALL BE PERMANENTLY AND CLEARLY IDENTIFIED AND RECORDED. LEGEND OT THERMOSTAT CONTROL SD SMOKE DETECTOR TS TEMPERATURE SENSOR OT OUTSIDE AIR TEMPERATURE SENSOR SUPPLY DUCT IN SECTION RETURN OR EXHAUST DUCT IN SECTION �--F VOLUME CONTROL DAMPER FIRE DAMPER ---�/1 CEILING SUPPLY DIFFUSER CEILING RETURN GRILLE O NOTES BY SYMBOL CUBIC FEET CFM PER MINUTE NK NECK AFF ABOVE FINISHED FLOOR DN DOWN CD CONDENSATE DRAIN EXH. EXHAUST SA SUPPLY AIR REQ'DREQUIRED RA RETURN AIR DMPR DAMPER FD FIRE DAMPER EXIBLE CANVAS � ECTIO N HORIZONTAL AIR SCOOP ROUND SUPPLY AIR DUCT. CONNECT BRANCH TO SUPPLY AIR DUCT DROP, ABOVE DIFFUSER. r VOLUME DAMPER UCT DROP (FLEXIBLE DUCT NOT ALLOWED) SUPPLY / RETURN AIR CONCENTRIC DIFFUSER MODEL NUMBER: 01-530-22 NOTE: INSTALL HORIZONTAL AIR SCOOP HAVING A CONTINUOUSLY CURVED CROSS SECTION AND BALANCING DAMPER AT DUCT CONNECTION TO DIVERT SUPPLY AIR INTO THE CONNECTED DUCTWORK. LENGTH OF SCOOP SHALL BE LIMITED TO THE WIDTH OF THE SUPPLY AIR ANNULAR SPACE. CONCENTRIC DIFFUSERS, AVAILABLE THROUGH YORK, CAN BE USED ON ALL VENDORS EQUIPMENT, CONTACT YORK NATIONAL PRICING FOR INFORMATION. LOCATE THE BOTTOM OF DIFFUSER AT 12'-0" AFF. TYPICAL SUPPLY BRANCH CONNECTION & BLANK -OFF DETAIL Scale: N.T.S. CONSULTANT: SEAL: HENRY D. MONTAGUE, PE 78172 THIS DRAWING SHALL NOT BE USED FOR CONSTRUCTION PURPOSES UNTIL THE SEAL AND SIGNATURE OF THE RESPONSIBLE REGISTRANT APPEARS ON THE DRAWING, AND PROPER PERMIT FORMS AND RELATED FEES ARE TRANSMITTED BY THE OWNER, OWNER'S AGENT OR CONTRACTOR TO THE AUTHORITY HAVING JURISDICTION. DATE ISSUED FOR REV 09/27/201 8 PEMB COORDINATION 1 2/1 8/201 8 PERMIT SUBMITTAL 01 /1 1 /2019 OWNER REVIEW 02/07/201 9 BID SET 03/04/2019 ADDENDUM 01 O1 Project Manager Drawn L. LONG T. PATTERSON Project Leader Checked L. LONG H. MONTAGUE Date Dept Mgr Approval 08/07/2018 H. MONTAGUE Client PALMETTO ZEPHYRHILLS-20th St, LLC P.O. BOX 1615 THOMASVILLE, GA 31 792 Office: (229) 226-0682 Contact: ,John Tate Project DOLLAR GENERAL 38965 CR 54 Zephyrhills, FL 33542 (City of Zephyrhills) Store #: 20360 Drawing Title HVAC LAYOUT DO NOT SCALE DRAWING Project No. Drawing No. ,JCDT.18.0233 M1 1 PLUMBING PLAN Scale. 1/8 — 1-0 PLUMBING FIXTURE SCHEDULE MARK DESCRIPTION HW CW WASTE VENT REMARKS CONNECTION CONNECTION CONNECTION CONNECTION 20"X18" WALL HUNG ADA LAVATORY W/ FRONT OVERFLOW, CONCEALED HANGERS & 4" CENTERS.AMERICAN STANDARD LUCERNE #0355.012 OR EQUAL. FAUCET SHALL BE POLISHED CHROME -PLATED CAST BRASS BODY WITH 4" SPOUT, 4" BRASS WRIST BLADE, 0.5 LAV-1 ADA LAVATORY 1/2" 1/2" 2" 1-1/2" GPM SPRAY AND POP-UP DRAIN. AMERICAN STANDARD MONTERREY #5502.175 PROVIDE WATTS MODEL USG-B-M1 ASSE 1070 MIXING VALVE OR EQUAL. INSULATED EXPOSED DRAIN & WATER PIPES WITH TRUEBRO LAV GUARD KIT #102 E-Z. PROVIDE SUPPLIES, STOP VALVES AND P-TRAP. FLOOR MOUNTED ADA VITREOUS CHINA ELONGATED 1.28 FLUSH GALLON CLOSE COUPLED TWO PIECE SIPHON JET WATER CLOSET, WC-1 ADA WATER CLOSET - 1/2" 4" 2" FLUSH TANK WITH 12" ROUGH -IN. AMERICAN STANDARD CHAMPION 4 "RIGHT HEIGHT" #2002.014 OR EQUAL. PROVIDE STOP VALVE, FLEXIBLE SUPPLY LINE, OPEN FRONT SEAT (AMERICAN STANDARD #5901.100 OR EQUAL). FLOOR MOUNTED ADA VITREOUS CHINA ELONGATED 1.28 FLUSH GALLON CLOSE COUPLED TWO PIECE SIPHON JET WATER CLOSET, ADA WATER CLOSET RIGHT- FLUSH TANK WITH 12" ROUGH -IN. AMERICAN STANDARD CHAMPION 4 "RIGHT HEIGHT" #2002.014 OR EQUAL WITH ALTERNATE TANK WC-2 HAND TRIP LEVER _ 1/2 4 2 ASSEMBLY #4266.804 (RIGHT HAND TRIP LEVER). PROVIDE STOP VALVE, FLEXIBLE SUPPLY LINE, OPEN FRONT SEAT (AMERICAN STANDARD #5901.100 OR EQUAL). PROVIDE 10 GALLON ELECTRIC WATER HEATER, 1.65KW @ 120V WITH MANUFACTURER SUPPLIED TEMPERATE AND PRESSURE RELIEF VALVE. (A.O. SMITH #EJC-10, OR EQUAL). PROVIDE THERMAL EXPANSION TANK. (AMTROL THERM-X-TROL ST-12, OR EQUAL). EXPANSION TANK SUPPORT: IT IS THE CONTRACTOR'S RESPONSIBILITY TO PROVIDE ADEQUATE SUPPORT FOR THE EXPANSION TANK. SUPPORT TO ADJACENT WALL ELECTRIC WATER OR FROM EXISTING STRUCTURE ABOVE WITH UNISTRUT. DO NOT SUPPORT FROM PIPE ALONE. EWH-1, 2 HEATER 3/4" 3/4" _ _ PROVIDE DRAIN PAN UNDER WATER HEATERS. PROVIDE SEISMIC STRAPPING ON WATER HEATERS. TERMINATE (EWH-1) DRAIN LINE IN WALL DRAIN BOX. HUB DRAIN (HD-1) TO AND (EWH-2) DRAIN LINE IN MOP SINK (MS-1). PROVIDE FULL SIZE T&P RELIEF LINE, (EWH-1 ONLY) SET WATER HEATER TEMPERATURE AT 110°F MAXIMUM. PROVIDE HOT WATER TEMPERING VALVE SET AT 110°F. REFER TO DETAIL 2/P2. (EWH-2 ONLY) REFER TO DETAIL 4/P2 FOR ADDITIONAL INFORMATION. 24" X 24" MOLDED STONE MOP SERVICE BASIN, WITH T DRAIN. FIAT #MSB-2424 OR EQUAL. PROVIDE SERVICE MS-1 MOP SINK 3/4" 3/4" 3" 2" FAUCET WITH PAIL HOOK & INTEGRAL VACUUM BREAKER, MOP BRACKET, FLAT STAINLESS STEEL STRAINER AND HOSE & BRACKET. FIAT #830 AA, 889 CC, 1453 BB & 832 AA OR EQUAL, PROVIDE SUPPLIES AND P-TRAP. BARRIER FREE ELECTRIC TWO -STATION, WALL MOUNTED, ELECTRIC DRINKING FOUNTAIN, BARRIER -FREE ACCESS (ADA), FRONT ONLY EASY TOUCH CONTROL, EDF-1 DRINKING FOUNTAIN 1/2" 2" 1-1/2" HIGH UNIT ON RIGHT. ELKAY #EZTLRDDC OR EQUAL. PROVIDE SUPPLY, STOP VALVE & P-TRAP. PROVIDE CANE APRON AS REQUIRED. FREEZE -PROOF WALL HYDRANT WITH BRONZE BODY & ANTI -SIPHON VACUUM BREAKER, BOX AND LOCKING COVER. PROVIDE WITH WH-1 WALL HYDRANT 3/4" - - _ HOSE CONNECTION AND MOUNT AT 24" ABOVE GRADE. WOODFORD #1365 OR EQUAL. WCO-1 WALL CLEAN -OUT - - AS SHOWN ON - SIZE & INSTALL AS SHOWN ON PLANS. JOSAM, ZURN OR EQUAL. PLANS HD-1 HUB DRAIN 1/2" - 3" 2" PROVIDE 3" PIPE SIZE WITH FUNNEL AND 1/2"0 TRAP PRIMER CONNECTION. JOSAM, ZURN OR EQUAL. PROVIDE PRESSURE DROP ACTIVATED BRASS TRAP SEAL PRIMER, WITH REMOVABLE FILTER SCREEN. MIFAB #M2-500. NO SUBSTITUTIONS. TP-1 TRAP PRIMER - 1/2" _ PROVIDE AIR GAP FITTING. MIFAB #MIGAP. NO SUBSTITUTIONS. PROVIDE DISTRIBUTION UNIT, WHERE TRAP PRIMER SERVES MULTIPLE FLOOR DRAINS, MIFAB #MI-DU-500. NO SUBSTITUTIONS. ECO-1 EXTERIOR CLEAN -OUT - - 4" - PROVIDE TRAFFIC RATED, 2-WAY, EXTERIOR CLEANOUT. TYLER PIPE #003519, OR EQUAL. AS SHOWN ON PROVIDE ADJUSTABLE FLOOR CLEANOUT WITH WATERTIGHT TAPERED THREADED PLUG AND ROUND SCORIATED SECURED TOP, FCO-1 FLOOR CLEAN -OUT _ _ PLANS ADJUSTABLE TO FINISHED FLOOR. SIZE & INSTALL AS SHOWN ON PLANS. JOSAM, ZURN OR EQUAL. I. E. - 4.00' FOR 0 CIVIL DWGS :ROM LAV, DN TO LAV-1 :ROM EDF-1 D :ROM LAV, DN TO LAV-1 NOTES: 1. PUBLIC SANITARY SEWER CONNECTION IS REQUIRED. 2. SEPTIC SYSTEM NOT ALLOWED WITHOUT WRITTEN APPROVAL OF DOLLAR GENERAL STORE DESIGN. 3. HOLDING TANK SYSTEMS ARE NOT ALLOWED. 4. LIFT STATIONS ARE NOT ALLOWED WITHOUT DOLLAR GENERAL APPROVAL. 5. CONTRACTOR RESPONSIBLE FOR ALL PUBLIC UTILITY CONNECTIONS (GAS, WATER, ELECTRIC, SEPTIC) AS WELL AS INFRASTRUCTURE REQUIRED BY UTILITY COMPANY. 6. COORDINATE CLEANOUT LOCATION WITH FIXTURE LAYOUT. 7. EWH-1 & EWH-2 REQUIRE PAN DRAIN TERMINATION AND MEANS OF PREVENTING AND CONTROLLING THERMAL EXPANSION. REFER TO 2017 FBC. FAI 1" CW T 2"VUP� 2" V DN TO WC-1 CY- 112" CW DN TO WC-1 SALES AREA 102 2" V DN TO WC-1 1/2" CW DN TO WC-1 ISOLATION VALVE (TYP) 2" V 2" V qW] WC-1 I— — 1" CW GENbER NEUTRAL I 104 ( I LAV-1 iL. HD-1 -- 40F I EDF-1 1" CW=--►I""i 3/4" CW to �t I LAV-1 GEND�R NEUTRAL 105 r__-1/2" CW WC-1 ENLARGED RESTROOM PLAN -1 1/2" V UP FROM LAV, 1/2" HW/CW DN TO LAV-1 EWH-1 11/2"VUP FROM EDF-1 N7.9 -3/4" CW DN TO WH-1 -3/4" HW/CW TO EWH-1, SEE 6/P2 FOR PIPING DIAGRAM 1/2" CW DN TO EDF-1 1 1/2" V UP FROM LAV, 1/2" HW/CW DN TO LAV-1 Scale: 1/4" = V-0" CONSULTANT: SEAL: HENRY D. MONTAGUE, PE 78172 THIS DRAWING SHALL NOT BE USED FOR CONSTRUCTION PURPOSES UNTIL THE SEAL AND SIGNATURE OF THE RESPONSIBLE REGISTRANT APPEARS ON THE DRAWING, AND PROPER PERMIT FORMS AND RELATED FEES ARE TRANSMITTED BY THE OWNER, OWNER'S AGENT OR CONTRACTOR TO THE AUTHORITY HAVING JURISDICTION. DATE ISSUED FOR REV 09/27/201 8 PEMB COORDINATION 1 2/1 8/201 8 PERMIT SUBMITTAL 01 /1 1 /201 9 OWNER REVIEW 02/07/201 9 BID SET 03/04/201 9 ADDENDUM 01 01 Project Manager Drawn L. LONG T. PATTERSON Project Leader Checked L. LONG H. MONTAGUE Date Dept Mgr Approval 08/07/201 8 H. MONTAGUE Client PALMETTO ZEPHYRHILLS-20th St, LLC P.O. BOX 1615 THOMASVILLE, GA 31 792 Office: (229) 226-0682 Contact: John Tate Project DOLLAR GENERAL 38965 CR 54 Zephyrhills, FL 33542 (City of Zephyrhills) Store #: 20360 Drawing Title PLUMBING PLANS AND SCHEDULE DO NOT SCALE DRAWING Project No. Drawing No. .JCDT.18.0233 P1 VACUUM SHUT-OFF VALVE UNION (TYP.) THERMAL EXPANSION TANK SIZE PER MANUFACTURER'S RECOMMENDATIONS C.W. MAKE-UP MIXING VALVE SPARCO MODEL: MX127LF H.W. TO FIXTURES (120°F) HEAT TRAP TEMPERATURE AND PRESSURE RELIEF VALVE DISCHARGE FULL SIZE OF VALVE DISCHARGE PIPE TO MOPSINK OR FUNNEL DRAIN AND TERMINATE WITH ELBOW TURNED DOWN HB 4" DEEP GALV DRAIN PAN INSTALL WATER HEATER ABOVE CEILING ON 8" 20 GA. STEEL STUD JOISTS SPACED 8" O.C. SPANNING SURROUNDING WALLS. COORDINATE STRUCTURAL SUPPORT FRAMING WITH G.C. 1" DRAIN LINE. ROUTE TO HUB DRAIN AND TERMINATE WITH ELBOW TURNED DOWN WATER HEATER EWH-1 DETAIL SHUT-OFF VALVE C.W. MAKE-UP H.W. TO FIXTURES THERMAL EXPANSION TANK SIZE PER MFG. RECOMMENDATIONS — TEMPERATURE AND PRESSURE RELIEF VALVE DISCHARGE FULL SIZE OF VALVE DISCHARGE PIPE TO MOP SINK OR FLOOR DRAIN AND TERMINATE WITH ELBOW TURNED DOWN 1" DRAIN LINE. ROUTE TO MOPSINK OR FLOOR DRAIN AND TERMINATE WITH ELBOW TURNED DOWN PROVIDE AND INSTALL WALL MTD. MOP HOLDER SO MOPS ALWAYS DRIP INTO MOP SINK. PROVIDE 2" AIR GAP FOR T&P RELIEF AND DRAIN LINE PIPING RECEIVING AREA FLOOR ALUMINUM CORNER GUARDS ON MOP SINK WING WALL. WATER HEATER @ RECEIVING \ SOIL OR WASTE Scale: No Scale WATER HEATER "EWH-2" Scale: No Scale VENT �TN I SEWER ~'�\ ✓,I NOTE: CONNECT VENT TO SOIL OR WASTE PIPING SOIL OR ABOVE CENTERLINE. UNDER SLAB HORIZONTAL WASTE ` j CONNECTIONS OF VENT PIPING TO WASTE SEWER SEWER SYSTEM PIPELINE SHALL NOT BE ALLOWED. VACUUM BREAKER EAT TRAP 4" DEEP GALV. DRAIN PAN 3/4"CW 1 /2"CW 3/4"CVV o �1"CW / �1" CW U/G. FOR CONT. >'-EWH-2REFER TO j 3/4"HW 1 "CW,,-'CIVIL DWGS. �o / 3/4"CW WC-2 3/4"CW--"'*1 1"CW II MS-1 ­'`/3/4"HW o\�----1/2"HW U a 1/2"CW ll /EWH-1 � Q'r 1`1�1/2"CW TRAP PRIMER r : 4 TP-1 TO LAV-1 HUB 1 /2"CW DRAIN WC-1 I 3/4"CW �1 /2"CW WH-1 LAV-1 EDF-1 INSTALL WATER HEATER ABOVE MOP SINK AT T-6" A.F.F. ON 8" 20 GA. STEEL STUD JOISTS SPACED 8" O.C. SPANNING SURROUNDING WALLS. COORDINATE STRUCTURAL SUPPORT FRAMING WITH GENERAL CONTRACTOR. INSTALL FRP @ 48" A.F.F. 60" WIDE ON THIS WALL. VENT PIPE INSTALLATION DETAIL Scale: No Scale 2"V 4" SAN FCO-1 EWH-1 TO DRAIN INTO HUB DRAIN (HD-1). EWH-2 TO DRAIN INTO MOP SINK (MS-1) REFER TO SHEET P1 FOR ADDITIONAL INFORMATION. COLD & HOT WATER DIAGRAM 4" VENT THRU WALL. ELBOW DN AND COVER W/ INSECT SCREEN —� Scale: No Scale 1►NV/ WC-1 ECO-1 I I 1 1/2" V j HD-1 i I i LAV-1 4" SAN I WCO-1 EDF-1 3" SAN 3" SAN WCO-1 "SAN REFER TO SHEET P1 FOR ADDITIONAL INFORMATION. SANITARY & VENT DIAGRAM Scale: No Scale EXTRA HEAVY DUTY CAST IRON ADJUSTABLE SCORIATED SECURED COVER. BRONZE TAPER THREAD PLUG WITH COUNTER SUNK HEAD FLUSH WITH I FLOOR LINE __.._ CLEAN -OUT TO BE TYLER PIPE - MODEL 003533 SERIES OR EQUAL FLANGE INSTALLATION SHALL BE FLUSH WITH SURROUNDING FLOOR SURFACES. WASTE LINE LENGTH TO SUIT FLOW � 1 I 4" FLOW 4„ H��� THIS DETAIL USED FOR 4" SANITARY LINE RUN BELOW FIXTURE RACKING. SEE PLANS. 1 2-WAY YARD CLEAN OUT DETAIL Scale: No Scale GENERAL PLUMBING NOTES & SPECIFICATIONS 1. GENERAL NOTES ARE APPLICABLE TO ALL PLUMBING WORKING DRAWINGS. 2. THE WORK SHALL BE EXECUTED IN STRICT CONFORMITY WITH BASE BUILDING SPECIFICATION AND WITH THE LATEST EDITION OF THE PREVAILING LOCAL PLUMBING AND BUILDING CODES AND ALL LOCAL REGULATIONS THAT MAY APPLY. IN CASE OF CONFLICT BETWEEN THE CONTRACT DOCUMENTS AND A GOVERNING CODE OR ORDINANCE THE MORE STRINGENT STANDARD SHALL APPLY. 3. ALL PLUMBING WORK SHALL BE COORDINATED WITH ALL OTHER TRADES BEFORE PROCEEDING WITH INSTALLATION. 4. PLUMBING CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL NECESSARY PERMITS AND FOR PAYING RELATED FEES. 5. ROUGH -IN DIMENSIONS OF TOILET FIXTURES MUST BE COORDINATED WITH GENERAL CONTRACTOR AND FIELD SUPERVISOR. 6. INSTALL BALL VALVES ON ALL BRANCH SUPPLY LINES. 7. PROVIDE ACCESS PANELS ON ALL INACCESSIBLE VALVES AND CLEANOUTS. ACCESS PANELS SHALL BE PROVIDED BY GENERAL CONTRACTOR. PLUMBING CONTRACTOR SHALL BE RESPONSIBLE FOR THEIR LOCATION. MOUNT SHUT-OFF VALVES NO HIGHER THAN 12'-8" AFF. 8. ALL WORK SHALL BE PROPERLY TESTED, BALANCED AND CLEANED. PROVIDE A ONE YEAR WARRANTY FROM DATE OF FINAL INSPECTION ON ALL PARTS AND LABOR. 9. FOLLOW PDI STANDARDS FOR WATER HAMMER ARRESTORS. 10. ALL FIXTURES TO BE SUPPLIED & INSTALLED BY PLUMBING CONTRACTOR,. 11. GENERAL CONTRACTOR SHALL COORDINATE WATER METER LOCATION AND INSTALLATION WITH LOCAL AUTHORITIES AND CIVIL DRAWINGS. 12. PROVIDE BUILDING SERVICE LINE 5'-0" FROM BUILDING LINE, OR INSIDE BUILDING FROM OUTLET SIDE OF METER AS SHOWN ON CIVIL SITE PLAN. COORDINATE EXACT LOCATION WITH CIVIL DRAWINGS AND AT JOB SITE. IF LOCAL MUNICIPALITIES REQUIRE BACKFLOW PREVENTION DEVICE, A MINIMUM RPZ TYPE SHALL BE PROVIDED. 13. SANITARY SEWER PIPING SHOWN IS BASED ON 0.1267FT FOR 3"-6" & 0.25"/FT FOR 2 1/2" OR LESS FOR ALL PIPING. COORDINATE BUILDING SEWER LOCATION AND INVERT ELEVATION WITH CIVIL DRAWINGS. 14. TRAP SEAL PRIMERS ARE TO BE PROVIDED AT NO ADDITIONAL COST TO OWNER IF REQUIRED BY LOCAL BUILDING CODE OFFICIALS. 15. VTR'S SHALL BE LOCATED A MINIMUM OF 5' FROM ANY PARAPET WALL AND 10, FROM ANY RTU AIR INTAKE. 16. FURNISH ALL MATERIAL, LABOR, EQUIPMENT, AND ACCESSORIES AS REQUIRED TO INSTALL COMPLETE PLUMBING AND HVAC PIPING SYSTEMS AS INDICATED ON MECHANICAL DRAWINGS AND IN THESE SPECIFICATIONS. 17. SANITARY SEWERS a. INSTALL SANITARY SEWERS, STACKS, VENTS, DRAINS, CLEANOUTS, ETC., AS INDICATED ON THE DRAWINGS. b. SEWERS TO BE PITCHED A MINIMUM OF 1/4" PER FOOT FOR 3" SIZES AND UNDER AND 1/8" PER FOOT FOR 4" SIZES AND LARGER OR TO GRADES INDICATED ON DRAWINGS. c. CHANGES IN DIRECTION AND BRANCH CONNECTIONS SHALL BE MADE WITH APPROVED DRAINAGE FITTINGS COMPATIBLE WITH THE PIPING SYSTEM MATERIAL IN WHICH IT IS INSTALLED. d. ALL FIXTURES AND SANITARY DRAINS SHALL BE VENTED AS INDICATED ON DRAWINGS AND IN ACCORDANCE WITH CODE. e. VENTS ARE TO BE EXTENDED THROUGH WALL IN ACCORDANCE WITH PEMB MANUFACTURER'S DETAILS OR THROUGH ROOF AS INDICATED ON DRAINS AND FLASHED WITH 4 LB. LEAD WITH VENT FLASHING TOP TURNED DOWN TWO (2) INCHES MINIMUM INSIDE PIPE. 18. BELOW GRADE SANITARY INSIDE BUILDING a. SERVICE WEIGHT- PVC AND CPVC ASTM A74-82 WITH ASTM C564-70 NEOPRENE COMPRESSION JOINTS OR NO -HUB b. PVC-DWV PLASTIC ASTM D1785 WITH ASTM D2665 DWV SOLVENT WELD SOCKET FITTINGS. 19. ABOVE GRADE SANITARY SEWER AND VENT a. NO -HUB CAST IRON PIPE CISPI 1-301-78. b. PVC-DWV PLASTIC ASTM D1785 WITH ASTM D2665 DWV SOLVENT WELD SOCKET FITTINGS (IN CONCEALED AREAS ONLY, PVC SHALL NOT BE INSTALLED IN CEILING PLENUMS). c. SCHEDULE 40 GALVANIZED STEEL PIPE, ASTM A53-83 WITH CAST IRON SCREWED FITTINGS ANSI B16.22 1983. 20. DOMESTIC WATER PIPING a. INSTALL DOMESTIC WATER PIPING AS INDICATED ON DRAWINGS. INCLUDE ALL FITTINGS, VALVES, HANGERS AND OTHER ACCESSORIES. EXTEND DOMESTIC WATER PIPING TO ALL FIXTURES AND EQUIPMENT REQUIRED FOR COMPLETE INSTALLATION. b. INCLUDE UNIONS, OR OTHER DISCONNECT MEANS, STOPS OR VALVES FOR ISOLATION OF FIXTURES AND EQUIPMENT. VALVES TO BE FULLY COMPATIBLE WITH PIPING FOR SERVICE INTENDED AS MANUFACTURED BY NIBCO, CRANE OR MILWAUKEE. INCLUDE HOSE OR DRAIN VALVES AT LOW POINTS WHERE FIXTURES CANNOT BE USED FOR DRAINAGE. c. PROVIDE WATER HAMMER ARRESTERS OF TYPE AS INDICATED ON THE DOMESTIC WATER RISER DIAGRAM. THESE SHALL BE ASSE 1010 OR PDI-WH2O1, PISTON TYPE WITH PRESSURIZED METAL -TUBE CUSHIONING CHAMBER AS MANUFACTURED BY SIOUX CHIEF, AMTROL, JOSAM OR ZURN. d. HANGERS ON INSULATED PIPE TO BE OUTSIDE OF INSULATION, SIZED ACCORDINGLY AND WITH A SUFFICIENT SADDLE TO PROTECT INSULATION. 21. DOMESTIC WATER PIPING SHALL BE AS FOLLOWS: a. ABOVE GRADE - TYPE "L" HARD COPPER ASTM B88-832 WITH WROUGHT COPPER FITTINGS ASTM B16.22 1980 AND NON -LEAD OR ANTIMONY SOLDER JOINTS. b. BELOW GRADE - CPVC OR PVC WITHOUT SPLICES OR FITTINGS. c. FLUSH, VENT AND SANITIZE ALL WATER PIPING WITH CHLORINE AS REQUIRED PER AWWA, LOCAL BUILDING DEPARTMENT AND HEALTH DEPARTMENT CODES. d. DOMESTIC HOT AND COLD WATER PIPING UNDER CONCRETE FLOOR TO BE COVERED WITH SAND SO THAT PIPING WILL 3" VENT THRU WALL. NOT BECOME EMBEDDED IN THE FLOOR SLAB. ELBOW DN AND COVER e. ALL PIPING UNDER CONCRETE FLOOR SHALL BE CPVC PIPING, CONTINUOUS. NO SPLICES OR FITTINGS WILL BE � ALLOWED. � W/INSECT SCREEN f. EXTREME CAUTION MUST BE TAKEN SO THAT NO PIPING AND INSULATION UNDER CONCRETE FLOORS BECOMES CRUSHED, CUT, SPLIT OR DEFORMED DURING THE POURING OF THE FLOOR SLAB. ECO-1 I I I I �1 1/2" V I I WCO-1 3" SAN MS-1 PROVIDE CLEANOUT WITH ADJUSTABLE CLEANOUT TOP WITH VARIATIONS SUITABLE FOR FLOOR COVERING (CARPET MARKER, RECESSED FOR TILE, SCORIATED FOR UNFINISHED FLOORS). CLEAN THE CLEANOUT PLUG AS SPECIFIED. TOP OF EXPOSED FCO AFTER INSTALLATION. APPLY TEFLON JOINT COMPOUND TO THE CLEANOUT PLUG THREADS FLOOR SLAB ON GRADE SAME SIZE AS SEWER UP TO 4" MAXIMUM MEMBRANE CLAMP AS REQUIRED FOR LONG SWEEP ELBOW AT DEPTH OF SEWER END OR TURN OF RUN SANITARY AND/OR COMBINATION WYE AND STORM SEWER, SIZE _ EIGHTH BEND IN RUN, PER PLAN F REDUCING TYPE IF REQUIRED. rj ENTER TOP OF PIPE. DIRECTION OF FLOWF REFER TO SPECIFICATIONS AND SCHEDULE FOR MORE INFORMATION. LOCATE AT BUILDING EXIT, AT ENDS OF RUNS, AT TURNS OF PIPE GREATER THAN 45°, AT 50' INTERVALS ON STRAIGHT RUNS, AND/OR WHERE SHOWN ON PLANS AND RISERS. PROVIDE BACKFILL PER ARCHITECTURAL SPECIFICATIONS. LOCATE CLEANOUT WHERE THERE IS 18" CLEAR AROUND, FOR ACCESSIBILITY. CONSULT LOCAL CODES AND OFFICIALS FOR OTHER REQUIREMENTS. FLOOR CLEAN OUT DETAIL Scale: No Scale LEGEND SS SANITARY SEWER -- — - -— DOMESTIC COLD WATER ---- DOMESTIC HOT WATER CD CONDENSATE DRAIN ------------ PLUMBING VENT UNION Ibi— PLUG COCK C - ELBOW -TURNED DOWN o----- ELBOW - TURNED UP -- - -- TEE - TURNED DOWN ----�---- TEE - TURNED UP -- --- GATE VALVE --COI--- BALL VALVE --�I--- CHECK VALVE _— SHUT-OFF VALVE IN VERTICAL LINE T & P RELIEF VALVE FCO FLOOR CLEANOUT &0 YCO YARD CLEANOUT -- —D­0=0 WH WALL HYDRANT --a-WCO WALL CLEANOUT FD FLOOR DRAIN HW HOT WATER DN DOWN CW COLD WATER VTR VENT THRU ROOF CONT. CONTINUATION U/G UNDER GROUND I.E. INVERT SAN SANITARY SEWER ELEVATION V PLUMBING VENT CD CONDENSATE DRAIN OUTSIDE INSIDE CORE DRILL WALL FOR EXISTING CIRCLE CUT NEW OR EXISTING STUD MASONRY OR CONCRETE CONSTRUCTION AND PROVIDE CONSTRUCTION v GALVANIZED STEEL PIPE FOR 6" AND SMALLER. PROVIDE 10 GAUGE GALVANIZED SHEET STEEL ROUND TUBE FOR 6" AND LARGER. CAULK SLEEVE IN PROVIDE GALVANIZED STEEL PIPE WITH;:: PLACE. RETAINING RING TO ANCHOR PIPE AND ACT AS A WATER STOP. GROUT IN PLACE FOR EXISTING MASONRY OR NEW PACK ANNULAR SPACE WITH CONCRETE CONSTRUCTION. FIBERGLASS INSULATION AND PROVIDE —_—_ _—_— WATERPROOF NON- SHRINK SILICONE SEALANT ON INSIDE AND OUTSIDE PROVIDE CAST IRON WALL PIPE WITH a FLUSH WITH WALL. RETAINING RING TO ANCHOR PIPE AND ACT AS A WATER STOP. POUR IN I 1 PLACE FOR NEW CONCRETE PROVIDE ESCUTCHEON FOR EXPOSED CONSTRUCTION. PIPE IN FINISHED SPACE NOTE: PIPING ARRANGEMENT SHOWN IN SCHEMATIC. ADJUST TO SUIT FIELD CONDITIONS. REFER TO SPECIFICATIONS FOR MORE INFORMATION ON INSULATION AND SEALANT. COORDINATE SLEEVE INSTALLATION WITH GENERAL CONTRACTOR. PIPING PENETRATION DETAIL 5 Scale: No Scale STUD IN WALL METAL CUP WITH (3) SHEET METAL SCREWS FASTENED TO BOTH STUDS ra O WATER HEATER J LATERAL SUPPORT SHELF MOUNTED WATER HEATER STRAP TO WALL AS INDICATED. (1) STRAP ON THE UPPER 1/3 & (1) ON THE LOWER 1/3 MAINTAINING A MINIMUM OF 4" FROM CONTROLS. (2) SHEET METAL SCREWS 3/4" WIDE 20 GAUGE STRAP 1T17101 1:4aai_NIX;7 INSTALL WATER HEATER ABOVE MOP SINK UPON 8" 20 GA. STEEL STUD JOISTS SPACED 8" O.C. SPANNING SURROUNDING WALLS AT T-6" A.F.F. AT MOP SINK AND ABOVE CEILING AT HALLWAY. COORDINATE STRUCTURAL SUPPORT FRAMING WITH G.C. WATER HEATER SHELF DETAIL Scale: No Scale CONSULTANT: SEAL: HENRY D. MONTAGUE, PE 78172 THIS DRAWING SHALL NOT BE USED FOR CONSTRUCTION PURPOSES UNTIL THE SEAL AND SIGNATURE OF THE RESPONSIBLE REGISTRANT APPEARS ON THE DRAWING, AND PROPER PERMIT FORMS AND RELATED FEES ARE TRANSMITTED BY THE OWNER, OWNER'S AGENT OR CONTRACTOR TO THE AUTHORITY HAVING JURISDICTION. DATE ISSUED FOR REV 09/27/201 8 PEMB COORDINATION 1 2/1 8/201 8 PERMIT SUBMITTAL 01 /1 1 /2019 OWNER REVIEW 02/07/2019 BID SET 03/04/2019 ADDENDUM 01 A01 Project Manager Drawn L. LONG T. PATTERSON Project Leader Checked L. LONG H. MONTAGUE Date Dept Mgr Approval 08/07/2018 H. MONTAGUE Client PALMETTO ZEPHYRHILLS-20th St, LLC P.O. BOX 1615 THOMASVILLE, GA 31 792 Office: (229) 226-0682 Contact: John Tate Project DOLLAR GENERAL 38965 CR 54 Zephyrhills, FL 33542 (City of Zephyrhills) Store #: 20360 Drawing Title PLUMBING DETAILS AND DIAGRAMS DO NOT SCALE DRAWING Project No. Drawing No. JCDT.18.0233 P2 L�J PENETRATION. PENETRATIONS 3/4" PLYWOOD 8'-9" WIDE X 5'-5" HIGH, FIRE RATED, NO VOIDS, PAINTED WHITE UNLESS t-nMC M1(`TATC0 lITLJCD\A/IQC THROUGH WALL. SEE ELECTRICAL SPECIFICATION NOTE'E' AND'H'. ELECTRICAL PANEL ELEVATION RECEIVING AREA 103 5 BUZZER PUSH BUTTON PROVIDE TOGGLE SWITCH AT WATER HEATER. A/21 Scale: NTS TO RTU-1 O RTU-1 u VERIFY ACTUAL HVAC ELECT. REQUIREMENTS WITH CONTRACTOR. (TYP). O GFCI, WP,A/10 LOW VOLTAGE VENDOR TO PROVIDE AND INSTALL ONE (1) 24 GA., 4 TWISTED -PAIR, CATEGORY -FIVE (CATS) DATA CABLE WITH MODULAR COMBO RJ-11/ RJ-45 JACK AT MANAGER'S OFFICE. CABLE TO BE RUN FROM JACK TO DATA HUB LOCATION WITH 6' LEFT COILED FOR INSTALLATION TO DATA HUB. A RJ-45 MALE FITTING SHOULD BE CRIMPED ON THIS END. DOLLAR GENERAL STORE OPENING TEAM WILL MAKE FINAL CONNECTION INTO THE DATA HUB. B/36 DEDICATED QUAD RECEPTACLE ® 3'-O" FOR CCTV EQUIPMENT DEDICATED QUAD RECEPTACLE ® 3'-0" SALES AREA 102 SO CORD (WHITE). ANCHOR TO PURLINS ABOVE. REFER TO ARCHITECTURAL PLANS FOR DIMENSIONS. (TYPICAL Ned. 3 RTU-2 O SECURITY OUTLET AT 7'-0" DEDICATED DUPLEX RECEPTACLE @48" FOR INTERFACE EQUIPMENT. DEDICATED QUAD RECEPTACLE ® 6'-0" FOR VSAT AND D-LINK EQUIPMENT ENLARGED OFFICE POWER PLAN TO RTU-2 O O GFCI, WP,A/10 �O A/7, 9,11 REFER TO REGISTER POWER POLE SO44 DETAIL 3/E4. B/2,4,6,8,10,12. 2 'F 21-111 A/34 00 3x � N' <,.:..��,u..........�__:. 00 00 "' a a N m. , 6'-711 m, 6'-711 0°, 6'-711 Q, 6'-711 a 6'-7" a, 5'-7" a, 4'-7" M 3'-31.1, . T-8" 907tylOka »1►1 Scale: 1/8" = V-0" SCALE 1/4" = V-0" RESTROOM EXHAUST FAN. CONNECT TO ROOM SENSOR LIGHT CONTROL SWITCH.--� RESTROOM EXHAUST FAN. CONNECT TO ROOM SENSOI LIGHT CONTROL SWITCH.— A/32 AM 2 Mae- 0 AUTOMATIC DOOR A/2 - B/21 GFCI A/23 B/21 A/28 l� {Jsw A/30 I I V A/28 s A/30 8 A/28 E A/30 J OFFICE 101 1 LEGEND g BUZZER - TORK MDL #TA725 W/ TRANSFORMER MDL#TA592 PUSH BUTTON 125V NEMA 5-20R DUPLEX. A/28 PANEL/CIRCUIT IN PANEL 9)sw 125V NEMA 5-20R DUPLEX. A/28 SPLIT WIRED. A/30 PANEL/CIRCUIT IN PANEL a 125/250V NEMA L14-20-R 4 PRONG TWIST LOCK 125V NEMA 5-20R QUAD. ® VACANCY SENSOR: GREENGATE DUAL TECH LOW VOLTAGE #VAC-DT-0501-R OR EQUAL. PROVIDE WITH SWITCH PACK. TEMPERATURE SENSOR: BY MECHANICAL LLI DISCONNECT 0 BLACK MAGIC POWER POLE PHONE JACK @ REGISTER O VOICE/DATA PORT = RJ-11, RJ-45 DATA JACK, PHONE COMBO @ OFFICE A/23 PANEL/CIRCUIT IN PANEL $m MOTION SENSOR SWITCH. LEVITON #EZ-FIND-ODS-10-IDW 20 AMP TOGGLE SWITCH NL NIGHT LIGHT CIRCUIT NEUTRAL 104 PROVIDE TOGGLE SWITCH AT RESTROOM WATER HEATER. A/19 GENDER NEUTRAL 105 ►-0 � 11 3 E1 20AMP OUTLET RECESSED @ 4' A.F.F. FOR ICE MERCHANDISER, NOTE: IF STORE IS 01 LABELED "RELOCATED", PROVIDE J BOX OVER ENTRY DOORS FOR CCTV. -(::A ELECTRICAL SPECIFICATIONS A. ALL WIRING SHALL BE CONTAINED IN CONDUIT OF PROPER SIZE. B. ALL WIRING SHALL CONFORM TO LOCAL, STATE, AND FEDERAL CODES. C. SERVICE IS TO BE MINIMUM 400 AMP, 3 PHASE (PREFERRED) 600 AMP 1 PHASE OR LARGER IF REQUIRED BY CODE OR ELECTRICAL LOAD. D. REQUIRED CUSTOM BUILT POWER POLE ASSEMBLIES AVAILABLE FROM D&P CUSTOM LIGHTS & PRODUCTS INC. PHONE: (800) 251-2200 OR (615) 350-7800, 7111 COCKRILL BEND INDUSTRIAL ROAD, NASHVILLE, TN 37209. SEE SHEET E3. E. EXTERIOR EXPOSED PHONE LINES TO BE INSTALLED IN RIDGED CONDUIT. PROVIDE EMERSON 3/4" X 5-FT. METALLIC CABLE U-GUARD #755, OR EQUAL. F. ELECTRICAL PANELS TO BE LABELED CORRECTLY AND WITH LEGIBLE PRINT. G. PHONE LINES - TWO RJ-11 PORTS. ONE (1) LOCATED IN OFFICE W/RJ-45 DATA JACK COMBO AND ONE (1) AT REGISTER. 24 GA. CAT 5, 4-PAIR TWISTED WIRE ONLY. USE BLUE AND BLUE & WHITE WIRES. HOOK TO LINE #1 TERMINAL IN RJ-11 JACK EACH PHONE JACK TO HAVE DEDICATED, SEPARATE HOME RUN TO DMARC. LABEL AS "PHONE" AT THE DESTINATION AND AT DMARC. PHONE COMPANY PROVIDES FINAL HOOK UP TO DMARC ONLY. PHONE JACKS ARE SUPPLIED AND WIRED BY CONTRACTOR. H. PROVIDE 1 1/2" EMT CONDUIT TO ACT AS ACCESS SLEEVE TO ALLOW PHONE COMPANY TO TERMINATE AT DMARC. CONTRACTOR TO PROVIDE & INSTALL PHONE WIRING & RJ-11 PHONE JACK FOR A COMPLETED WORKING SYSTEM PRIOR TO PHONE COMPANY FINAL HOOK-UP. I. ALL 120 VOLT OUTDOOR RECEPTACLES TO HAVE "WET LOCATION - IN USE" COVERS. J. ALL CONDUCTORS TO BE COPPER, #12 AWG MINIMUM SIZE, OR SIZE AS REQUIRED BY LOAD AND OVER CURRENT PROTECTION. K. SEE EMS SHEETS EMS1 AND EMS2 FOR ENERGY MANAGEMENT SYMBOLS AND INFORMATION. L. ELECTRICIAN TO PROVIDE 1Y2" CONDUIT WITH PULL STRING FOR SATELLITE LINE. REFER TO 3/A3 AND 1/S1 FOR LOCATION. M. ALL POWER AND DATA TO BE ROUTED OVERHEAD. UNDER SLAB IS NOT ALLOWED. N. WIRE SIZE O BE #8 OR #10 AS REQUIRED FOR COOLERS/FREEZERS. O. MOUNT ALL REFRIGERATOR OUTLETS AT 12" AFF. P. WIRE SIZES SHALL BE BASED ON THE 60 DEGREE CELSIUS AMPACITIES FOR WIRE SIZES #14 THRU #1 AWG AND 75 DEGREES CELSIUS FOR WIRE SIZES #1/0 AND LARGER. Q. BRANCH CIRCUIT WIRE SIZES AND CONDUITS SHALL BE INCREASED FROM THOSE INDICATED ON THE PLANS AS REQUIRED TO PREVENT EXCESS VOLTAGE DROP. BRANCH CIRCUITS SHALL BE INSTALLED WITH WIRES OF SUFFICIENT SIZE SO THAT THE VOLTAGE DROP BETWEEN THE PANEL AND THE LOAD DOES NOT EXCEED 3% TO MEET FLORIDA'S BUILDING CODE, ENERGY CODE PART C405.7. IF- ELECTRICAL KEYED NOTES O TEST/RESET STATION FOR STAND ALONE DUCT DETECTOR. ONE FOR EACH DEVICE. SEE KEY NOTE 2 ON THIS SHEET. SIMPLEX #4098-9842 IS SPECIFIED WITH PIEZO AND LED INDICATOR. ® LOCATION SHOWN FOR MECHANICAL UNITS ARE ONLY APPROXIMATE. CONTRACTOR SHALL CONSULT MECHANICAL AND STRUCTURAL DRAWINGS TO DETERMINE ACTUAL UNIT LOCATIONS. PROVIDE 1/2" PENETRATION THRU ROOF WITHIN FOOTPRINT OF UNIT FOR USE WITH CONTROL WIRING TO UNIT BY OTHERS. PROVIDE PROPER WATERSEAL (TYPICAL). O FACTORY MOUNTED POWERED CONVENIENCE OUTLET. FIELD VERIFY THAT OUTLET IS POWERED. PROVIDE WP, GFCI RECEPTACLE AT ALL UNITS AND WIRE TO BREAKER IN PANEL "A" IF THEY ARE NOT FACTORY PROVIDED. PHOTOELECTRIC DUCT DETECTOR WITH HOUSING. TIE TO LED READOUT RECESSED IN DUCT STAND ALONE DEVICE, 120V. SIMPLEX #4098-9687 IS SPECIFIED WITH 4098-9842 CONTROL STATION. PROVIDE ONE DEVICE PER UNIT. MOUNT DEVICE IN SUPPLY AIR DUCTWORK. DEVICE SHALL BE PROVIDED AND WIRED TO THE CONTROL STATION BY THE ELECTRICAL CONTRACTOR. HIRE THE MECHANICAL CONTRACTOR FOR INSTALLATION IN DUCTWORK AND CONNNECTION TO SHUT DOWN CONTROLS. ELECTRICAL CONTRACTOR SHALL PROVIDE ALL REQUIRED RELAYS AND 120V POWER. DO NOT POWER DUCT DETECTORS FROM HVAC LOW VOLTAGE. SUBMIT SHOP DRAWINGS FOR APPROVAL. PLACE ANY REQUIRED LABELING ON CEILING TILE DIRECTLY BELOW UNIT. O MOUNT DISCONNECT SWITCH AT UNIT. ALL DISCONNECTS SHALL BE HEAVY DUTY.FUSES TO BE TYPE RK-5 TYPE. BUSSMAN FRN-R-(AMP) FUSES ARE SPECIFIED. MECHANICAL THERMOSTAT AT 8'-0" AFF. 0 VACANCY SENSOR. SENSOR SHALL CONTROL LIGHTS AND TOP HALF OF THE DUPLEX RECEPTACLES INDICATED AS SPLIT WIRED, (A/28). SPLIT WIRED RECEPTACLES. CIRCUIT A/30 SHALL BE 'ALWAYS ON', CIRCUIT A/28 SHALL BE CONTROLLED BY THE VACANCY SENSOR. RECEPTACLE SECTIONS THAT ARE AUTOMATICALLY CONTROLLED SHALL BE PERMANENTLY MARKED PER ASHRAE STANDARDS. SO WHITE ELECTRICAL CORD IS REQUIRED. SEE SHEET Al, NOTE 25 AND 25A. CONFIRM THE FINAL NUMBER AND LOCATION OF OUTLETS IN THE SALES AREA WITH THE FINAL DOLLAR GENERAL FIXTURE PLAN. CONSULTANT: SEAL: SEAN PATRICK PIC-KELL, PE 83946 0%A1111III//,,, a*: s3948 � .� STATE OF `•BAN A — THIS DRAWING SHALL NOT BE USED FOR CONSTRUCTION PURPOSES UNTIL THE SEAL AND SIGNATURE OF THE RESPONSIBLE REGISTRANT APPEARS ON THE DRAWING, AND PROPER PERMIT FORMS AND RELATED FEES ARE TRANSMITTED BY THE OWNER, OWNER'S AGENT OR CONTRACTOR TO THE AUTHORITY HAVING JURISDICTION. DATE ISSUED FOR REV 09/27/201 8 PEMB COORDINATION 12/18/2018 PERMIT SUBMITTAL 01 /1 1 /2019 OWNER REVIEW 02/07/2019 BID SET 03/04/2019 ADDENDUM 01 ni Project Manager Drawn L. LONG G. COLLINS Project Leader Checked L. LONG M. GOOD Date Dept Mgr Approval 08/07/2018 M. GOOD Client PALMETTO ZEPHYRHILLS-20th St, LLC P.O. BOX 1615 THOMASVILLE, GA 31 792 Office: (229) 226-0682 Contact: John Tate Project DOLLAR GENERAL 38965 CR 54 Zephyrhills, FL 33542 (City of Zephyrhills) Store #: 20360 Drawing Title POWER PLAN DO NOT SCALE DRAWING Project No. Drawing No. JCDT.18.0233 E1 1 SITE LIGHTING AND POWER PLAN Scale: 1"=20'-0" EXISTING UTILITY POLE WITH NEW TRANSFORMERS. VERIFY EXACT LOCATION AND SERVICE VOLTAGE WITH UTILITY COMPANY LIGHT POLE CHAMFER EDGES ON BASE NOTE: LIGHT POLE, BASE PLATE AND ANCHOR BOLTS SHALL BE DESIGNED AND PROVIDED BY THE LIGHT POLE MANUFACTURER. UPON REQUEST BY THE LOCAL BUILDING OFFICIAL, CALCULATIONS SHALL BE SUBMITTED BEARING THE SEAL AND SIGNATURE OF A PROFESSIONAL ENGINEER LICENSED IN THE STATE WHERE THE PROJECT IS BEING CONSTRUCTED, EMPLOYED BY THE LIGHT POLE MANUFACTURER. GROUND LUG W/ #4 AWG CU TO REBAR IN FOOTING BASE PLATE AND ANCHOR BOLTS (BY MANUFACTURER) BASE COVER 343 TIES WITHIN 5" FROM TOP 545 VERTICAL REBAR o M GROUNDING CONNECTORS ,-- FINISH GRADE #4 COPPER GROUND WIRE :I— CONDUIT & WIRING #3 TIES @ 12" O.C. #15 FELT (2 LAYERS) Zh Zh Z_ 0 ti 3" MINIMUM GROUND PLATE (COPPER) OR 24" DIA 10-TURNS OF #4 BARE COPPER WIRE PANCAKE (20' MINIMUM) 2 POLE FOUNDATION DETAIL Scale: NTS LIGHT FIXTURE DESCRIPTION TYPE DESCRIPTION COUNT HP SINGLE HEAD LED PARKING LOT FIXTURE, TECHLIGHT LIGHTING: #LSBT-IC-8-T3-F-1-BZ FULL CUTOFF, WITH TYPE 3 OPTICS, DARK BRONZE FINISH. MOUNT ON 25' POLE, TECHLIGHT #SSP-25-4-7-11-BZ FOR SINGLE MOUNTED LUMINARIE. PROVIDE A 3'-0" POLE BASE 2 SITE LIGHTING NOTES 1. FINAL SIGN CONNECTION AND UNDERGROUND CONDUIT IS LANDLORD RESPONSIBILITY. PROVIDE CONDUIT FROM THE ELECTRICAL PANEL TO LOCATION OF THE MONUMENT SIGN BASE. BURY CONDUIT UNDER PARKING AREA. THE CONDUIT IS TO BE 1" AND HAVE ONE SET OF 6/2 WIRE WITH GROUND AND A 20-AMP SINGLE POLE BREAKER AT THE PANEL. A TEMPORARY 3' TALL STAKE SHALL BE PROVIDED TO DESIGNATE THE MONUMENT SIGN LOCATION UNTIL THE SIGN IS PERMANENTLY INSTALLED. REMOVE POST AFTER SIGN IS INSTALLED. 2. SEE SHEET E2 FOR BUILDING MOUNTED LIGHTS INFORMATION. 3. COORDINATE LOCATION OF LIGHT POLE BASES WITH CIVIL FOR REQUIRED CLEARANCE FROM THE RETAINING WALL BASE. CONSULTANT: SEAL: SEAN PATRICK PIC-KELL, PE 83946 �1 RICK #il j��,,,�� ♦ if M. No.93946 tC, STATE OF ot+ 0 � ��►` "lilt llt I THIS DRAWING SHALL NOT BE USED FOR CONSTRUCTION PURPOSES UNTIL THE SEAL AND SIGNATURE OF THE RESPONSIBLE REGISTRANT APPEARS ON THE DRAWING, AND PROPER PERMIT FORMS AND RELATED FEES ARE TRANSMITTED BY THE OWNER, OWNER'S AGENT OR CONTRACTOR TO THE AUTHORITY HAVING JURISDICTION. DATE ISSUED FOR REV 09/27/2018 PEMB COORDINATION 12/18/2018 PERMIT SUBMITTAL 01/11/2019 OWNER REVIEW 02/07/2019 BID SET 03/04/2019 ADDENDUM 01 zo_ _\1 Project Manager Drawn L. LONG G. COLLINS Project Leader Checked L. LONG M. GOOD Date Dept Mgr Approval 08/07/2018 M. GOOD Client PALMETTO ZEPHYRHILLS-20th St, LLC P.O. BOX 1615 THOMASVILLE, GA 31792 Office: (229) 226-0682 Contact: John Tate Project DOLLAR GENERAL 38965 CR 54 Zephyrhills, FL 33542 (City of Zephyrhills) Store #: 20360 Drawing Title ELECTRICAL SITE LIGHTING AND POWER PLAN DO NOT SCALE DRAWING Project No. Drawing No. .JCDT.18.0233 ES1 Luminaire Schedule Symbol Qty Label Lumens/Lamp Arrangement LLF Description -� 5 G N.A. SINGLE 0.900 LHSWP-1-C-M-T3-C-ONE BRICK TYPE 3 700MA LED WALL PACK -p 5 HB N.A. SINGLE 0.900 LSBT-1-C-X-T3-F-ONE BRICK TYPE 3 1400MA LED WALL MNT 421N UPSWEEP ARM -� 2 HP N.A. SINGLE 0.900 LSBT-1-C-X-T3-F-ONE BRICK TYPE 3 1400MA LED ( SEE NOTES) Luminaire Location Summary LumNo Label Z Tilt 1 G 16.5 0 2 G 16.5 0 3 G 12 0 4 G 12 0 5 G 12 0 6 HB 18.5 0 7 HB 18.5 0 8 HB 18.5 0 9 HB 18.5 0 10 HB 18.5 0 11 HP 24 0 [12 HP 24 0 Calculation Summary Label CalcType Units Avg Max Min Avg/Min Max/Min SITE Illuminance Fc 0.88 9.8 0.0 N.A. N.A. PARKING AND DRIVE Illuminance Fc 2.71 9.7 0.0 N.A. N.A. LED LIGHT FIXTURE- 24' 25' POLE PARKING LOT (EX: GRADE AT 0.0') �III�I RETAINING WALL --- Notes: 1. Calculation at grade. 2. See Luminaire Location Summary for wall luminaire mounting height. 3. Arm mnt wall fixtures estimated with 2' rise from mounting. 4. Based on 25' poles plus 3' AFG bases. 5. Pole location grade is 4' below parking. 25' poles and 3' bases should make the fixture approximately 24' above parking surface. TOP OF BASE (EX: GRADE AT -1. THIGH CONCRETE POLE BASE GRADE (EX: GRADE AT -4. SCHEMATIC SITE POLE INSTALLATION DETAIL Scale: No Scale + + + + + + + + + + + + *0. + + o.o 0.0 #�.o + + + + + 0.0 0.0 0.0 0.0 0.0 0.0 0:0 0.0 0.0 0.0 0.0 1i.0 0.0 0.0 0.0 0.0 0 0.0 0.0 0.0 t.0 *0. + *0. *0. *0. *0. *0. + + + + *0. 0 0.0 0 0 0 0 0 0.0 0.0 0.0 0.o o + + + + + *0. *0. + + �.o + + o.o o.0 0.0 0:0 0.0 0:0 0 0 0.0 +o.o + + + + o.o o.o o.0 0.0 �i.0 + + + 0.0 0.0 o.a + + + + + + + + o.o o.o o.0 0.0 0.0 0.0 0.0 0:0 + + 0.0 0.o f�.o + + 0.0 0.0 o.a 10,0 "0.0 t.o I � t + ( ! I + +:*0.+ + o.o + + + + 0.0 o.0 0 0.0 ( o.o + + o.o o.o + o. o .o + + + + + + o.o o.o 0.0 0.0 0.o a:o + + o. o 0 + + 0 0.0 0.0 $.o + + ' o.o o.o #�.o + o. q.o + + + + 0 0 0.0 0.0 0.0 o o.o o.o i + + + + + + + + + + + + + + + : + + + + + 1 + + + +; + + + o.o o.o cr9 0 0.0 o.o o.o o.o o. o 0 0.0 0.0 0.0 0.0 0.0 0.0; o. o 0 0 0.0 0.0 0.0 ; .o 0.0 0.0 0. q.o .0 $.0 0.0 t # 0 0 0.0 0.0 I € 0.0 0.0 0.0 0.0 U- O LL oz_ a.0_ o.o- O,A U-• PRQPERTY LINE o.o- o.o- 9.� 9,6- 9-� 9 4- 9 aa- a 9- 9 e- +9 9- 9-8- .0 .o o.0 0.0 0.0 0.0 0.0 0.0 i 0.0 0.0 0.0 +0.0 0.0 0.0 0.0 +0.0 0.0 0.0 0.0 0.0 0 +0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 +0.1 0.0 0.0 0.0 0.0 0.0 .0 0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 .0 0.0 0.0 01......._........__...+DA__A t...... .:_n'��.......-Q.LJ - � a2-- __.:�_ fi 0.5 0.3 0: 0.1 0.0 � - '... 0.0 .0 � ��0.0 0.0 0.0 I Jillf + + J + € + 0.0 �.0 0 0 .0 .0 .0 0.1 +0.2 + 0.4 +0.5 + + + + 0.5 0.5 0.5 0.5 +0.5 + + + + + + + + + + 0.5 0.5 0.5 0.5 0.7 1.0 1.8 1.7 1.4 1.1 +0.8 + + + + 0.3 0.1 0.0 0.0 +0.0 t 0.0 .0 � 0.0 +0.0 0.0 _ + I + + it + +0.0 + i0.0 0.0 0:0 0.0 .0 0.1 0.6 0.9 1.2 1.2 1.1 1.3 1.1 1.2 1.2 1.2 1.4 1.1 1.3 1.8 +3.2 2.9 2.1 1.6 1.0 +0:5 0.1 0.1 0.0 +0.0 0.0 I .0 � 0.0 0.0 0.0 + + + + + _ + + + + + + + + + + + + + + + + + + + + I + + t.0 0.0 +0.0 0.0 € 0.0 .0 0.1 0.8 2.6 1.6 1.7 1.6 2.6 2.5 1.7 1.8 1.9 2.8 +3.0 4.6 4.4 #2.8 1.8 1.2 0.6 0.2 0.1 0.0 0.0 0.0 .0 (I 1 0.0 0.0 +0.0 t f _ _ ..It ......... a +0.0 , +O:L__�- +o 0.0 .0 0.1 +0.8 +5.6 .3 4.0 2.2 1.5 0.7 0.2 +0.0 0.0 .0 1 0.0 0.0 0.0 3 5 4 G G G L 0.0 +0:0m-­-�:0- 0.0 0.0 0.0 0.0 0.0 � g 4.4 +5.5 4.6 +2.5 1.6 +0.7 0,� 0.1 0.1 _..0.. � 0 0.0 0.0 0.0 +0.0 H E1 t I 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 4.4 4.8 4.1 2.6 1.8 t.9 1.4 0.2 0.2 0.1 0.1 +0. 0.0 +0.0 +0.0 0.0 0.0 0.0 0.0 0.0 0.0 +0.0 +0.0 4:3 +5.0 4.1 +3.1 2.3 1.3 1 .8 0.7 0.6 0.4 +O.a 0.1 0.1 0.0 0.0 I 3 + + + + + + + + + 0.0 0.0 0.0 O.Q 0.0 0.0 0.0 0.0 """�=��_ +3.5 + + + + + + + + 2.6 1.7 .2 1.1 1.1 0.6 +0. 0.1 0.1 0.0 0.0 0.0 0.0 0. 0.0 0.0 0.0 0.0 +3.5 2.7 1.9 .5 1.6 1:5 0.7 0.1 0.2 : +0.1 0.1 0.1 € I + + + + + + + + + + + + + + + + + + + +0.0 0.0 0.0 0.( 0.0 0.0 0.0 0.0 6.2 6.0 +5.0 3.4 2.7 2.0 1.9 2.2 .1 0.8 0.t 0.4 0.2 0.1 0.1 f + + + + + + + _ + + + + + + + + + + 0.0 0 0 0,0 0. +0.0 O.a 0.0 0.0 _ 0 +7.1 6.1 4.2 +3.1 2.3 2.3 2.6 .7 1.0 0. 0.6 0.3 0.2 0.1 IW z _- + + + + n+ + + + +G + HJ� + G + HEI + H� + + + + + + + + + 0.0 0 - 0:0 - - 0. � 0.1 +0.4 0.8 1.6 3.3 4.7 +6.a 6.8 8.3 8.8 8. 8 5 3 t1.7 t 3 8.5 1.9 +9.8 4.9 3.4 +2.6 2.9 3.1 .9 1.3 1.� O.S t $$$: 1.4 0.2 0.1 la z + + a+0.1 +0.4 +0.7 1.5 +2.9 +4.1 + A + .0 +8.5 1.2 1. % 3 .2 8.2 t .5 € +7:8 +8.5 +9.7 +8.4 +6. +4.7 +3.4 +2.6 +3.1 # .2 .1 11 1.4 � +0.7 +0.4 +0.3 +0.1 o.o �:o 0.0 �O. HIP + + + + + + + + + + +; r + + + + + + + + + + % + + + 0.0 0.0 0.0 �,O 0.1 +0.3 0.6 1.3 +2.2 2.9 3 4. +5.9 +5.9 0 6:3 .8 6.4 6.0 6.0 6.3 6.9 +5.2 4.3 3.1 2.4 2.6 2.7 .8 1.1 1 0. 0.4 0.2 +0.1 r + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + 0.0 +0.0 0.0 010 0.1 0.2 0.4 0.9 1.6 2.0 2� 3.8 4.2 4.4 4.7 4.9 4.8 4.8 4:8 4.8 +5.0 4.4 4.1 3.6 2.6 1.9 2.0 2.4 .4 0.9 6 0. 0.2 0.2 0.1 I + + + + + + + + + + + + + + + + + + + + 0.0 0.0 0.0 0 0.1 0.1 0.2 0.5 0.8 1.1 1.3 1.7 2.2 2.7 3.0 +A +3.8 4.0 4.4 4.5 4.1 3.4 # .o +2.8 + + + 2.4 1.9 1.5 + + + + + + 5 1.8 1.7 0.8 .4 0. 0.2 0.1 0.1 i + + +' + + + + + + + + + + + + + + + + + + + + + + i + +0.0 0.0 0:0 Q 0 0.0 0.1 0.1 0.2 0.3 0.4 0.5 0.8 1.3 1. 2 7 4 4.0 4.2 3.5 2.8 2.2 1. 1.6 1.3 1.1 1.2 1.3 L2 +0.7 .3 0.2 +0.1 0.1 +0.1 I o.oi.o o.o 0 0.0 0.0 0.1 0.1 0.1 0.1 0.2 0.2 0.3 0.7 1. 1: 3 2.8 3.2 3.3 2.9 2.5 2.0 1. 1.3 +0.9 0.8 0.8 1.8 0.7 0.5 1.2 0. 0.1 0.1 0.0 1 fLP + + + +0.0 +0.0 + + 0.0 .0 0.0 +0.0 +0.0 + + + + + + + + + .0 � 0.0 0.1 � 0.1 0.2 0:5 0.9 1.2 1.4 1.8 2.0 q�i.0 + + + + 1.9 1.5 1.3 1.1 +0:9 + + + + + + 0.5 0.4 0.4 0.3 0.3 0.2 p.1 +0.� + + 0.0 0.0 t.0 i HP + + + ,1*0.+ � 0.0 0:0 0.0 .0 � +0.0 + + + 0.0 0.0 0.0 +0.0 + + 0.0 0. + + + + + + 0.1 0.1 0.3 0.4 0.5 0.5 +0.8 + + + + + + + + 1.5 1.6 1.1 0.6 0.5 0.4 0.4 0.2 +0.2 + + + ++ + 1 0.1 0.1 0 0.1 .0 0 0.0 0.0 +0.0 + + + + + ' 0.0 0.0 0.0 .0 � 0.0 +0.0 + + + + + + + 0.0 0.0 0.0 0.0 0.0 0.0 0.1 +0.1 + + + 0.2 0.3 0.5 +0.7 + + + 1.0 1.0 0.8 +0.6 + + + + 0.4 0.2 0.2 O.t +0.1 + + + 0.1 0.1 0.0 +0 0 �.0 0 + + + 0 0.0 0.0 0.0 ............. .._.... _ ._. . + + + + + + + + + + + + + + + + + + + + + + + + + 0.0 0.0 0.0 to. 0 0.0 +0.0 0.0 +0:0 0.0 0.0 0.0 0.0 0.1 +0.1 0.1 0.2 0.3 0.4 +0.5 0.5 0.5 0.3 1.2 0.2 0.1 0.1 0.1 0.0 +0.0 +0./ Ojo j 0 0.0 0.0 +0.0 � -�- + + + + + + + + + PROP RTY LINE + + + + o.0 0.0 0.0 0.0 -fie -tee �-e ---e � _fit _ fie - -r ---e-r -r 4-2 41i, ......... .- a -_ - ..__ _. -moo... -�b-o--#i-o-� o.o t 0.0 .a! t.0 1.0 1.0 0.0 0.0 0.0 o;o 0.0 0.0 0.0 1.0 10.0 10.0 10.0 10.0 10.0 10.0 0.1 0.1 0.1 +0.2 t.2 0.2 0.2 $.1 +0.1 0.1 0.1 0.0 0.0 0.0 +o.o #�.0_. �._.a.e 0.0 0.0 +o.o o.o + + + + + + + + + + + + + + 0.0 0.0 0.0 0 0"0 0.0 0.0 0:0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 +0.1 + + 0.1 0.1 +0.1 + + + + + 0.1 0.1 0.1 0.1 0.10.0 +0.0 10. + + + + + 0 0.0 0.0 0.0 0.0 0.0 +0.0 +. 6 --- +. ---�-- ---+-0 - + �.o -���� o.o oo.#�.o o.0 + + + 0.0 0.0 0.0 t.0 + + + + + + + + + 0.0 0.0 0.0 0.0 0.0 0.1 0:1 0.1 0.1 +0.1 + + 0.1 0.1 +o.o + + + + + 0:0 0.0 0.0 +o.o +o.o o.o o.o $.o 0.0 0.0 $.o o.o + + + + + *0. + o.o +o.o $.o 0.0 �.o o.o o.o o.o o.o o.o o.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.o o.o o.a o.o o.o o.o o.o o.o o.o o o.o o.0 0.0 0.0 SITE LIGHTING PHOTOMETRIC PLAN Scale: 1/20" = P-0" CONSULTANT: SEAL: SEAN PATRICK PIC-KELL, PE 83946 �tpy\01111011111 �r *�t,��OCK w 1* • No, 83.,946 ,p STATE OF �`�rt�r�tttttitkwe THIS DRAWING SHALL NOT BE USED FOR CONSTRUCTION PURPOSES UNTIL THE SEAL AND SIGNATURE OF THE RESPONSIBLE REGISTRANT APPEARS ON THE DRAWING, AND PROPER PERMIT FORMS AND RELATED FEES ARE TRANSMITTED BY THE OWNER, OWNER'S AGENT OR CONTRACTOR TO THE AUTHORITY HAVING JURISDICTION. DATE ISSUED FOR REV 09/27/201 8 PEMB COORDINATION 12/18/2018 PERMIT SUBMITTAL 01 /1 1 /2019 OWNER REVIEW 02/07/2019 BID SET 04 03/04/20191 ADDENDUM 01 1 AN Project Manager Drawn L. LONG G. COLLINS Project Leader Checked L. LONG M. GOOD Date Dept Mgr Approval 08/07/201 8 M. GOOD Client PALMETTO ZEPHYRHILLS-20th St, LLC P.O. BOX 1615 THOMASVILLE, GA 31792 Office: (229) 226-0682 Contact: John Tate Project DOLLAR GENERAL 38965 CR 54 Zephyrhills, FL 33542 (City of Zephyrhills) Store #: 20360 Drawing Title SITE LIGHTING PHOTOMETRICS PLAN DO NOT SCALE DRAWING Project No. Drawing No. .JCDT.18.0233 ES2 J- REQUIRED NATIONAL ACCOUNT VENDORS COMPANY CONTACTS PHONE # REQUIRED ITEMS W RAINBIRD IRRIGATION LOCAL RAIN BIRD DISTRIBUTER WWW.RAINBIRD.COM IRRIGATION SYSTEMS U) w W o EUCLID CHEMICAL PHIL BRANDT 877-438-3826 CONCRETE POLISHING SYSTEMS w 0� Z w_ W_ COMPANY PBrandt@euclidchemical.com Z Z � RETRO-PLATE SYSTEMS SCOTT MAXFIELD 801-641-6796 CONCRETE POLISHING SYSTEMS 0 00 scott.maxfield@retroplatesystem.com RECORD DOOR SYSTEMS MICHAEL VINNIK 704-290-0234 IN,KY,MD, MODEL #5100 SERIES dollargeneral@recorddoors.com OH, PA,VA,WV 0111 STANLEY ACCESS DENNIS WEBB 256-776-8902 AR,AZ CA CO CT,DE IL IA KS LA MA ME MI MN MO MODEL #DG2000 w Z TECHNOLOGIES DGdoors@sbdinc.com ND,NE,NH,NJ,NM,NV,NY,OK,OR,RI,SD,TX,VT,WI o � ASSA ABLOY ENTRANCE ROSS MERKLING 609-528-2580 AL, FL, GA, MS, NC, SC, TN MODEL #SL500 n w SYSTEMS dollargeneral.besam.us@assaabloy.co GIRTMAN AND ASSOCIATES MIKE MOYNAHAN 615-350-6000 INTERIOR DOORS AND FRAMES AL,AR,AZ,CA,CO,FL,GA,IA,KS,LA,MS,MN, U)o dgconstruction@bass-security.com AND RESTROOM ACCESSORIES MO,NE,NM,NV,OK,OR,SC,SD,TN,TX,WI o woo COOK & BOARDMAN GROUP JOE HARRELL 336-837-0673 INTERIOR DOORS AND FRAMES CT,DE,IL,IN,KY,MA,MD,ME,MI,NC,NH,NJ, o Z o nationalsales@cookandboardman.com AND RESTROOM ACCESSORIES NY,OH,PA,RI,VA,VT,WV w SHERWIN WILLIAMS LOCAL SHERWIN WILLIAMS STORE PAINT, PRIMER, CONCRETE SEALER AND BLOCK FILLER MC CUE CORPORATION KEVIN O'NEILL 678-492-4026 koneill@mccue.com TRIM KIT INCLUDES BUMPER GUARDS AND CART STOP z YORK NATIONAL ACCOUNTS 800-481-9738 HVAC UNITS york-dollargeneral-be@jci.com AR, CO, IL, IN, KY, KS, MO, OH, OK, WV CARRIER HASAN KHALIL 315-432-7655 HVAC UNITS Hasan.Khalil@carrier.utc.com CT, IA, MA, ME, MI, MN, ND, NE, NH, NJ, NY, PA, RI, SD, VT, WI Q ~ LENNOX SCOTT MACDONALD 972-497-6781 HVAC UNITS _ D dollargeneral@lennoxind.com AL, AZ, CA, DE, FL, GA, LA, MD, MS, NC, NM, NV, OR, SC, TN, TX,VA ROOF CURB SYSTEMS CLIFTON REASOR 800-683-5848 RTU CURB DollarGeneral@roofcurb.com CURBS PLUS INC. ALLAN THRAILKILL 888-639-2872 RTU CURB alan.thrailkill@curbs-pius.com U) Q KCC INTERNATIONAL INC. GREG CONRAD 800-382-2872 RTU CURB _ Iwo gconrad@kcccurbs.com Q CED - CONSOLIDATED ROBERT DECKER 270-781-2229 ELECTRICAL SWITCH GEAR AR,AZ,CA,CO,IA,IN,IL,LA,KS,KY,MI,MN, ELECTRICAL DISTRIBUTORS robertd@cedbgky.com MO,MS,ND,NE,NM,NV,OK,OR,SD,TX,WI W Q NESCO CHRIS TRACY 800-244-6980 ELECTRICAL SWITCH GEAR AL,CT,DE,FL,GA,MA,MD,ME,NC,NH,NJ, w u (D dollargeneral@needhamelectric.com NY,OH,PA,RI,SC,TN,VA,VT,WV USLED DANA PORTER 713-337-3836 ELECTRICAL LIGHTING AR,CO,IA,IL,IN,KS,KY,MI,MN,MO, z PAUL JEZIOROWSKI DGUSLED@usled.com SUPPLIES ND,NE,OH,OK,SD,WI,WV = LEDS MICHAEL STRINGER 920-915-4010 ELECTRICAL LIGHTING AL,AZ,CA,CT,DE,FL,GA,LA,MA,MD,ME,MS o KYLE KNAPP DGORDERS@leds-Ilc.com SUPPLIES NC,NH,NJ,NM,NV,NY,OR,PA,RI,SC,TN,TX,VA,VT D&P CUSTOM LIGHTING NATIONAL ACCOUNT SALES 800-251-2200 CUSTOM PONDER POLES CROSSCOM NATIONAL ANDREA LEMAY - - 847 850 6297 COCTDEFLIAILINKSMAMDMEMIMN LOW VOLTAGE &VOICE/DATA , Qdollargeneral@crosscomnational.com MO,ND,NE,NH,NJ,NY,OH,PA,RI,SD,VT,WI,WV ASD CHRIS RUDNITSKI 828-624-1046 LOW VOLTAGE & VOICE/DATA AL,AR,AZ,CA,GA,KY,LA,MS,NC,NM,NV, 0 0 U) crudnitski@asd-usa.com OK,OR,SC,TN,TX,VA GRAYBAR JEROME BANNISTER 615-743-3202 office, 615-924-2135 cell CABLE TRAY DollarGeneral@graybar.com EMERSON CLIMATE WEBSITE: USER NAME: dollargeneralbid EMS SUPPLIER NOTE: CUSTOMIZED DOLLAR GENERAL EMS PANEL REQUIRES TECHNOLOGIES http://dollargeneralbid.ectsolutions.net PASSWORD: dollargeneralbid STORE #, CITY, STATE, ZIP CODE & QTY. OF HVAC UNITS OF THE INSTALL SITE WHEN ORDERING. W STANLEY CONVERGENT DAN GOLDSMITH 740-215-8913 INTERIOR FIRE ALARM PANELS w SECURITY SOLUTIONS RECOMMENDED NATIONAL ACCOUNT VENDORS PRE-ENGINEERED METAL BUILDING COMPANY CONTACTS PHONE # VP BUILDINGS DAVID ENGLISH 901-568-4537 PRE-ENGINEERED METAL BUILDING DEnglish@vp.com STAR BUILDING SYSTEMS JEFF HORN 866-664-8899 PRE-ENGINEERED METAL BUILDING NUCOR BUILDING SYSTEMS BOB BARRY 315-622-4440 m PRE-ENGINEERED METAL BUILDING CORPORATE: 260-837-7891 https://www.formrouter.net/forms@MBSIN/dgquote.pdf BIG BEE STEEL BUILDINGS, INC. KEVIN BUSLER 800-633-3378 PRE-ENGINEERED METAL BUILDING CHIEF BUILDINGS ERIN SULLIVAN 308-385-4628 PRE-ENGINEERED METAL BUILDING erin.sullivan@chiefind.com IRRIGATION COMPANY CONTACTS RAIN BIRD IRRIGATION LOCAL RAIN BIRD DISTRIBUTER WWW.RAINBIRD.COM IRRIGATION SYSTEMS REQUIRED NATIONAL ACCOUNTS FOR ENGINEERING AND CONSTRUCTION MATERIAL TESTING COMPANY CONTACTS PHONE # ATC ASSOCIATES, INC. LESLIE GREENWOOD 205-733-8775 www.atcassociates.com leslie.greenwood@atcgc,com BUILDING AND EARTH MATT ADAMS 205-836-6300 www.buildingandearth.com SCIENCES, INC. dollargeneral@buildingandearth.com _ EAS PROFESSIONALS, INC. JERRY MARRONE 864-234-7368 www.eas-pro.com dollargeneral@eas-pro.com PROFESSIONAL SERVICE TERESA HEBNER 770-424-6200 #3030 www.psiusa.com INDUSTRIES, INC. (PSI) teresa.hebner@psiusa.com TERRACON JOHN MEADOW 770-623-0755 #353 www.terracon.com dollargeneral@terracon.com NOTE: MATERIAL TESTING IS REQUIRED ON ALL TRIPLE NET LEASES. PROTOTYPE MANAGEMENT TEAM COMPANY CONTACTS PHONE # MJM ARCHITECTS GARY CONWAY 615-244-8170 www.mjmarch.com dg@mjmarch.com ENTECH MITCH SIMPSON 615-373-2640 www.entechtn.com email@entechtn.com NATIONAL ACCOUNT & CONTACT INFORMATION SUBJECT TO CHANGE DOLLAR GENERAL STORE Store#20360 38965 CR 54, Zephyrhills, Florida 33542 Based on 9,100 SF Prototype T " (Left Corner Entry, Right Side Delivery) release date: 0 3 / 2 0 / 2 018 Product Approval Information Sheet Project Name: Dollar General --Zephyrhiiis (City of Zephyrhills), FL Project Address: 38965 CR 54 As required by Florida Statute 553.842 and Florida Administrative Code 9B-72, please provide the information and product approval number(s) for the building components listed below as applicable to the building construction project for the permit number listed above. You should contact your product supplier if you do not know the product approval number for any of the applicable listed products. Information regarding statewide product approval may be obtained at: www.fioridabuilding.org. Z J O < Q � � Z mw > N O O I--w CO w Q a 11110011110 000111311 11INNO 00011110 i C���C ■■■❑❑■ ■■■❑❑■ RitVa%l DATE: ?I CITY orF ZI;F°HA-p,,:' ILI, L`U!f DIN°37. O F''IC'IAL GENERAL: CS COVER SHEET OWNER: F1 FIXTURE PLAN / LIFE SAFETY PLAN ARCHITECTURAL: A00 ARCHITECTURAL SITE DETAILS Al FLOOR PLAN A2 EXTERIOR ELEVATIONS A3 SECTIONS AND DETAILS A3a SECTIONS AND DETAILS A3b SECTIONS AND DETAILS A4 ROOM FINISH SCHEDULE AND SALES FLOOR ELEVATIONS A5 DOOR SCHEDULE AND DETAILS A6 ENLARGED PLANS AND TOILET ROOMS A7 SIGN DETAILS A8 SIGN BRACING DETAILS A9 REFLECTED CEILING PLAN A10 WALL TYPES All GENERAL NOTES Al2 ARCHITECTURAL SPECIFICATIONS STRUCTURAL: S1 STRUCTURAL GENERAL NOTES S2 FOUNDATION PLAN AND SCHEDULES S3 FOUNDATION SECTIONS AND DETAILS S4 SECTIONS AND DETAILS S5 CONCRETE SUMMARY MECHANICAL: 10101 Ml HVAC LAYOUT ■ M2 HVAC SCHEDULES / NOTES / DETAILS PLUMBING: ®® P1 PLUMBING PLANS AND SCHEDULE ® ■ P2 PLUMBING DETAILS AND DIAGRAMS ■■■❑❑■ ■■■❑❑■ ■■■❑❑■ ■■■❑❑■ ■■■❑❑■ ELECTRICAL: E1 POWER PLAN E2 LIGHTING PLAN E3 POWER POLE AND POWER TERMINAL DETAILS E4 CABLE TRAY LAYOUT PLAN E5 THREE PHASE ELECTRICAL PANELS EMS1 EMS / LOW VOLTAGE PLAN EMS2 CPU TERMINAL DIAGRAM ES1 ELECTRICAL SITE LIGHTING AND POWER PLAN ES2 SITE LIGHTING PHOTOMETRICS PLAN ES3 SITE LIGHTING FIXTURE CUT SHEETS Category Manufacturer Product Description Limitation of Use Product Approval A. Exterior Doors Swinging Curries Doors Outswing commercial Steel Approved for use in +601-60 FL 8394.1 — R5 Door HVHZ psf (Pair) (Pair) +801-80 FL 8394.3 — R5 psf (Single) (Single) Category Manufacturer Product Description Limitation of Use Product. Approval A. Exterior Doors Automatic Assa Abloy Entrance Besam Resilience Full Breakout Approved for use in +701-70 FL 16128.1 — R3 Systems US Inc. Bi-part Large and Small Missile HVHZ Impact Door System Category Manufacturer Product Description Limitation of Use Product Approval C. Claddina D. Storefront Storefront Kawneer Series "IR-500 Flush and wet Approved for use in +651-65 FL 8787.2 — R5 Glazed" Aluminum Storefront HVHZ psf System — L. M.I. E. Metal Suildinu Manufacturer (PEM81 Metal Wall Panels Nucor Building Reverse Classic wall Panel Not approved for +45.0 f FL 2686.3 — R5 Systems use in HVHZ -45 psf Roof Deck Nucor Building CFR Panel Not approved for +NIA1 FL 4890.1 — R8 Systems use in HVHZ -108.8 psf In addition to completing the above list of manufacturers,: product description and State approval number of the products used on this project, it is the Contractor's or Authorized Agent's responsibility to have a legible copy of each manufacturer's printed instructions, along with the list above,. on the job site available to the inspector. COMPONENTS AND CLADDING DESIGN WINDLOAD PRESSURE: 137 mph (vult) ROOF Oj +18 psf -43 psf O +18 psf h=19'-9' -72 psf O +18 psf -108 psf WALLS O +43 psf -46 psf Q +43 psf -57 psf STRUCTURE IS NOT LIGHT FRAME TRUSS CONSTRUCTION �O moo,, 5 3 2 3 5 2 l� 2 0 5 3 2 3 5 O O O a=7'-0" TYP 130'-8" GENERAL NOTES: ��Pi5+ra I �4 o� BUILDING MUST COMPLY WITH ALL BUILDING (FEDERAL, STATE AND LOCAL), FIRE, ADA AND HEALTH DEPARTMENT CODES. NO TAPERED COLUMNS ALLOWED. MAINTAIN INTERIOR CLEAR SPACE AS REQUIRED ON PLANS. METAL BUILDING COLUMNS SHALL BE STRAIGHT. COLUMNS AND INTERIOR COLUMNS MAY REQUIRE WRITTEN APPROVAL. MAINTAIN INTERIOR CLEARANCE BETWEEN FACE OF COLUMNS AND SALES FLOOR AS NOTED ON PLANS PROTECT OPENINGS NOTE: ALL NEW FIRE WALLS REQUIRED TO PREVENT THE PASSAGE OF SMOKE AND FIRE SHALL BE IDENTIFIED WITH WORDING "FIRE AND SMOKE BARRIER -PROTECT OPENINGS PER NFPA 101 :8.3.2.4 LIGHT FRAME TRUSS NOTE: THIS PROJECT DOES NOT USE LIGHT FRAME TRUSS CONSTRUCTION CONSULTANT: SEAL: JOHN BENEDICT POLSINELLI, AR96059 THIS DRAWING SHALL NOT BE USED FOR CONSTRUCTION PURPOSES UNTIL THE SEAL AND SIGNATURE OF THE RESPONSIBLE REGISTRANT APPEARS ON THE DRAWING, AND PROPER PERMIT FORMS AND RELATED FEES ARE TRANSMITTED BY THE OWNER, OWNER'S AGENT OR CONTRACTOR TO THE AUTHORITY HAVING JURISDICTION. DATE ISSUED FOR REV 09/27/201 8 PEMB COORDINATION 1 1 /27/2018 OWNER REVIEW 12/18/201 8 PERMIT SUBMITTAL Project Manager Drawn L. LONG B. JACKSON Project Leader Checked L. LONG G. KARANFILOVSKI Date Dept Mgr Approval 08/07/2018 G. KARANFILOVSKI Client PALMETTO ZEPHYRHILLS-20th St, LLC 7 P.O. BOX 1615 THOMASVILLE, GA 31 792 Office: (229) 226-0682 Contact: John Tate Project DOLLAR GENERAL 38965 CR 54 Zephyrhills, FL 33542 (City of Zephyrhills) Store #: 20360 Drawing Title COVER SHEET DO NOT SCALE DRAWING Project No. Drawirlo. i )CDT.18.0233 \'S I. __ ___II' 'III I _ I I- I I ___ _I- I I I I I 1 'I 1 1 'Fill "I 1111PI91-T"11IT R^I'lhi'IpjI'1' I 'I III]'I ' " I 1 1 FBI 10 0 ESM-10 ESM-10 VR-10 COKE I PEPSI REPSI I j O n L�J A - SERVICE COUNTER PLAN B - ELEVATION SERVICE COUNTER DETAILS Scale: 1/4" = V-0" NOTE: FRONT CHECKOUT COUNTER TO BE PROVIDED BY DOLLAR GENERAL AND INSTALLED AT DOLLAR GENERAL'S DIRECTION. COUNTERS SHALL INCLUDE A PORTION OF AT LEAST 36" IN LENGTH WHICH IS NO MORE THEN 34" ABOVE THE FINISH FLOOR. COUNTERS SHALL BE ON AN ACCESSIBLE ROUTE. HECK WRITING SURFACE 6 5 4 (::3 2 FIXTURE PLAN NORTH LIFE SAFETY PLAN Scale: 3/16" = V-0" BUILDING CODE COMPLIANCE BUILDING CODE 2017 FLORIDA BUILDING CODE 5th EDITION 2017 FLORIDA FIRE PREVENTION CODE 5th EDITION 2017 FLORIDA PLUMBING CODE 5th EDITION 2017 FLORIDA MECHANICAL CODE 5th EDITION 2014 NFPA 70 NATIONAL ELECTRIC CODE 2017 FLORIDA ACCESSIBILITY CODE (CHAPTER 1 1) 5th EDITION s 2017 FLORIDA ENERGY CODE (CHAPTER 1 3) v 2015 NFPA 101 LIFE SAFETY CODE OCCUPANCY (M) MERCANTILE (S 309) (S-2) STORAGE, SEPARATED (S 31 1 .3) CONSTRUCTION CLASSIFICATION II-B NON-SPRINKLERED (T 601) MIN INTERIOR FINISH CLASS 'C' (T 803.11) BASE HEIGHT & AREA LIMITATIONS MAX HEIGHT- STORIES = 2 STORIES (T 504.4) MAX HEIGHT- FEET = 55 FEET (T 504.3) MAX ALLOWABLE AREA PER FLOOR (Aa) = 12,500 SQ FT (T 506.2) Aa = 112,500 + [12,500 x 0]} = 12,500 ACTUAL BUILDING PROPERTIES ACTUAL AREA = 9,100 SQ FT ACTUAL HEIGHT (OVERALL) = 21'-4" FIRE RESISTANCE RATING REQUIREMENTS (T 601) STRUCTURAL FRAME = 0 HR BEARING WALLS- EXTERIOR = 0 HR BEARING WALLS- INTERIOR = 0 HR NON -BEARING WALLS- EXTERIOR = 0 HR NON -BEARING WALLS- INTERIOR = 0 HR FLOOR CONSTRUCTION = 0 HR ROOF CONSTRUCTION = 0 HR DESIGNED OCCUPANT LOAD (T 1004.1 .2) SALES FLOOR (7,298 sf/ 30) = 244 OCCUPANTS BREAK ROOM and OFFICE 0 47 sf/ 100) = 2 OCCUPANTS TOILET ROOMS and HALL (249 sf/ 100) = 3 OCCUPANTS RECEIVING (990 sf/ 300) = 4 OCCUPANTS TOTAL OCCUPANT LOAD = 253 OCCUPANTS EGRESS REQUIRED/ PROVIDED: # EXITS REQUIRED AND PROVIDED: GROUND 2 REQ'D / 3 PROVIDED (T 1006.3.1) EXIT WIDTH REQUIRED 0.20"/ PERSON EXIT CAPACITY REQUIRED = 50.4" EXIT CAPACITY PROVIDED = 1 70" (S 1005.3.2) MAXIMUM LENGTH OF EXIT ACCESS TRAVEL NOT TO EXCEED "M' = 200'-0" (T 1017.2) ACTUAL MAX. TRAVEL DISTANCE = 1 1 7'-4" PLUMBING FACILITIES REQUIRED: (T 403.1) PLUMBING FACILITIES PROVIDED: WATER CLOSET LAVATORY OCCUPANTS WATER CLOSET LAVATORY EA. SEXREQ'D REQ'D PROV'D NON -GENDER 126 1 per 500 1 per 750 UNISEX 1 1 NON -GENDER 126 1 per 500 1 per 750 UNISEX 1 1 DRINKING FOUNTAIN 1 PER 1000 (1) SERVICE SINK PROVIDED (1) HIGH/LOW DRINKING FOUNTAIN PROVIDED EMERGENCY LIGHT W/ BATTERY BACKUP " I l LIGHTED EXIT SIGN W/ BATTERY BACKUP DENOTES PATH OF EGRESS —.-- — — — — — — — —� — REMOTENESS BETWEEN EXITS DIAGONAL DIMENSIONS = 144'-0" SEPARATION OF EXITS = 144'-0" _ 2 = 72'-0" ACCTUAL DISTANCE BETWEEN EXIT DOORS IS: 104'-8" DENOTES 2A1 OBC FIRE EXT. W/ TOP C@ +42" A.F.F. F.E. MAXIMUM 75 FEET TRAVEL DISTANCE TO REACH FIRE EXTINGUISHER CONSULTANT: SEAL: JOHN BENEDICT POLSINELLI, AR96059 THIS DRAWING SHALL NOT BE USED FOR CONSTRUCTION PURPOSES UNTIL THE SEAL AND SIGNATURE OF THE RESPONSIBLE REGISTRANT APPEARS ON THE DRAWING, AND PROPER PERMIT FORMS AND RELATED FEES ARE TRANSMITTED BY THE OWNER, OWNER'S AGENT OR CONTRACTOR TO THE AUTHORITY HAVING JURISDICTION. DATE ISSUED FOR REV 09/27/201 8 PEMB COORDINATION 1 1 /27/2018 OWNER REVIEW 12/1 8/201 8 PERMIT SUBMITTAL Project Manager Drawn L. LONG B. JACKSON Project Leader Checked L. LONG G. KARANFILOVSKI Date Dept Mgr Approval 08/07/2018 G. KARANFILOVSKI Client PALMETTO ZEPHYRHILLS-20th St, LLC P.O. BOX 1615 THOMASVILLE, GA 31 792 Office: (229) 226-0682 Contact: John Tate Project DOLLAR GENERAL 38965 CR 54 Zephyrhills, FL 33542 (City of Zephyrhills) Store #: 20360 Drawing Title FIXTURE PLAN / LIFE SAFETY PLAN DO NOT SCALE DRAWING Project No. Drawing No. JCDT.18.0233 F1 _ I.. L-A _ _ _�11 I I171 'll N'•II I+{- IwIII IIIIIP I"ll -IIP1111IFHIIII 1111'NIIIIII' fil I 1 111:1I J III I I I I Ill 5 Aoo BOND BEAM W/ #4 CONT )RIZONTALJOINT REINF 16" O.C. @ 24" C/C GROUT INF CORE TYP ?" EXPANSION JOINT .LER @ 24" C/C X 6'-0" NG DOWELS #7 CONT TOP AND ,TTOM DUMPSTER WALL SECTION 3 A00 TYP 6" SEALED CONIC PAD - COORDINATE WITH CIVIL DRAWINGS 8" SPLIT FACE CMU (COLOR TO MATCH BUILDING) 2 EA EQUAL GATES 1 .9" OD GALV FRAME W/ 4"x8'H CEDAR SLATS ATTACHED W/ SELF TAPPING SCREWS. PROVIDE SWING GATE WHEEL HINGES, CENTRAL GATE STOPS & LATCH W/ EYE FOR PADLOCK --- DUMPSTER )PROVIDE STEEL RECEIVER SLEEVE SET IIN CONC @ CANE BOLT CONC APRON COORDINATE WITH CIVIL Scale: 1/2" = V-0" 19'-4" 18'-0" 2'-4" DUMPSTER 2 A00 @ GATE NOTE: REF CIVIL PLANS FOR LOCATION DUMPSTER ENCLOSURE PLAN Scale: 1/4" = V-0" KEY NOTES lO PRECAST CONCRETE CAP WITH SLOPED TOP O8" SPLIT FACE CMU (COLOR TO MATCH BUILDING) 01 /2" x 4" LONG S.S. DOWEL EPDXY FULL OINTO 03/4" X 2 1/2" DEEP FIELD -DRILLED HOLES @ 32" O.C. 8" POURED CONCRETE FOUNDATION WALL i PROVIDE SLOPE 0 d- 3/8" WD xl 1/4" DEEP SAWCUT CONTROL JOINT CONCRETE APRON W/ W2.9xW2,9 X 6"x6" WWF N 5 ENLARGED DETAIL Aoo N CONCRETE FILL 6" 0 X 1 /8" PAINTED STEEL BOLLARD FILLED SOLID WITH CONCRETE SLOPE TO GRADE MIN 1/4" PER FOOT PREMOULDED JOINT FILLER GRADE LEVEL 24"0 POURED CONCRETE PIER FOOTING 7 BOLLARD DETAIL GATE LOCK W/FLAT MOUNT F� & ADA STYLE LEVER GATE 1 .9" O.D. GALV FRAME W/ 0 4" x 8' WHITE VINYL GATE OR °O APPROVED EQUAL. ATTACHED CENTER CONCRETE PER MANUFACTURER CAPSTONE ON FINISHED STANDARDS. PROVIDE HINGES WALL & SET IN MORTAR AND LATCH W/ EYE FOR SETTING BED. FILL JOINTS PADLOCK. 1 7'-0" WITH SEALANT CLEAR GATE OPENING GATE POST (TYP)----, 9 A00 I E I I I (( Nil' 3 k r } I Ll €[ LL _ I f'� x t E i j SI E t i QQ - I 00 i� in LINE OF PIER BELOW PIVOTING CANE BOLT FABRICATED FROM 1 /2" DIA STL ROD PROVIDE 3/4" DIA 4" DEEP SLEEVES IN CONC PAVEMENT FOR CANE BOLTS J SWING GATE WHEEL AT EACH GATE � GATE ELEVATION 8" SPLIT FA (COLOR TC BUILDING) III III IL UJ� AT POST PAVING (SEE PLAN) 1 /2" PREMOULDED JOINT FILLER AT PAVING TOOLED EDGES CONCRETE APRON W/ REI N F 2'-0" #4 DOWEL @ 18" OC zfr— — W2.9 X W2.9 X 6 X 6 WWF f�;'� - x' 'c x.__x G "Z ".. GRAVEL BASE REBAR CONCRETE APRON DETAIL DUMPSTER ENCLOSURE - SIDE ELEVATION Scale: 1/2" = V-0" Scale: 1" = V-0" GATE POST 1 /2" THICK STL PLATE -SLOTTED STL BOLTS & WASHERS HINGE COLLAR W/ GREASE FITTING COLLAR WELDED ALL AROUND POST GATE POST 1 /2" THICK STL PLATE -SLOTTED STL BOLTS & WASHERS STL BOLTS HINGE COLLAR W/ GREASE FITTING COLLAR WELDED ALL AROUND POST 9 GATE HINGE DETAIL CONSULTANT: SEAL- JOHN BENEDICT POLSINELLI, AR96059 THIS DRAWING SHALL NOT BE USED FOR CONSTRUCTION PURPOSES UNTIL THE SEAL AND SIGNATURE OF THE RESPONSIBLE REGISTRANT APPEARS ON THE DRAWING, AND PROPER PERMIT FORMS AND RELATED FEES ARE TRANSMITTED BY THE OWNER, OWNER'S AGENT OR CONTRACTOR TO THE AUTHORITY HAVING JURISDICTION. DATE ISSUED FOR REV 09/27/201 8 PEMB COORDINATION 1 1 /27/201 8 OWNER REVIEW 12/1 8/201 8 PERMIT SUBMITTAL Project Manager Drawn L. LONG B. JACKSON Project Leader Checked L. LONG G. KARANFILOVSKI Date Dept Mgr Approval 08/07/2018 G. KARANFILOVSKI Client PALMETTO ZEPHYRHILLS-20th St, LLC P.O. BOX 1615 THOMASVILLE, GA 31 792 Office: (229) 226-0682 Contact: John Tate Project DOLLAR GENERAL 38965 CR 54 Zephyrhills, FL 33542 (City of Zephyrhills) Store #: 20360 Drawing Title ARCHITECTURAL SITE DETAILS DO NOT SCALE DRAWING Project No. Drawing No. JCDT.18.0233 A00 N Cm r,. DRINK FIXTURE WALL MOUNTING SUPPORT NOTES:. 1. PROVIDE AND INSTALL 2X6 WHITE PINE - GRADE 2 OR BETTER. 2. PROVIDE AND INSTALL 2X4 WHITE PINE - GRADE 2 OR BETTER. 3. FASTEN THE 2X6 TO THE WALL WITH THE TOP EDGE OF THE BOARD AT 78" A.F.F., STARTING FROM THE END OF THE LAST COOLER AND STOPPING 5'-0" FROM REAR WALL. 4. FASTEN THE 2X4 TO THE WALL WITH THE TOP EDGE OF THE BOARD AT 12" A.F.F., STARTING FROM THE END OF THE LAST COOLER AND STOPPING 5'-0" FROM REAR WALL. 5. PRE -DRILL PILOT HOLES IN ALL BOARDS PRIOR TO INSTALLATION TO PREVENT WOOD SPLITS. 6. SECURE THE 2X6 WITH THREE SELF -TAPPING SCREWS PER WALL STUD. MINIMUM SCREW SIZE IS 4"x 4'. 7. FASTEN THE 2X4 WITH WITH ONE SELF -TAPPING SCREW PER WALL STUD. MINIMUM SCREW SIZE IS 4"x4, . 8. CAULK THE EDGES OF THE 2X6 AT THE TOP AND BOTTOM WHERE IT MEETS THE WALL PRIOR TO PAINTING. 9. PRIME AND PAINT BOTH BOARDS TO MATCH WALL COLOR, WA SEE SHE[ N LO N INTERIOR FACE OF PEMB FRAMING BEYOND ANCHOR BOARD: CONTRACTOR TO PROVIDE AND INSTALL 2x6 WHITE PINE GRADE 2 OR BETTER TOP OF FIXTURE TO BE AFFIXED TO DRIED PINE NAILER BY DOLLAR GENERAL MERCHANDISING DEPT FIXTURE SUPPLIED & INSTALLED BY DOLLAR GENERAL MERCHANDISING DEPT MTL LINER PANELS CONTRACTOR TO INSTALL VERTICAL 2X WOOD FRAMING SO THAT HORIZONTAL ANCHOR BOARDS RUN CONTINUOUSLY PAST PEMB COLUMNS ANCHOR BOARD: CONTRACTOR TO PROVIDE AND INSTALL 2x4 WHITE PINE GRADE 2 OR BETTER FINISHED FLOOR EIFS PILASTER (REF EXTERIOR ELEVATIONS) 5/8" EXTERIOR GRADE GYPSUM BOARD SHEATHING ON METAL WALL PANELS VINYL FACED R-13 BATT INSULATION + R-6.5 CONTINUOUS INSULATION WITH VAPOR BARRIER (BY PEMB). 1/2" GYP BOARD OVER LINER PANELS - REFER TO INTERIOR ELEVATIONS FOR LOCATIONS DEFS ON 4" CMU PILASTER (REF EXTERIO ELEVATIONS) V-4" V-4" EIFS BULLNOSE ........ ......... ......... ..............._ r T 'METAL BUILDING COLUMNS SHALL BE STRAIGHT. TAPERED COLUMNS & INTERIOR COLUMNS REQUIRE WRITTEN APPROVAL. MAINTAIN INTERIOR CLEARANCE COI OF 68'-0" BETWEEN FACE OF COLUMNS ON SALES FLOOR DETAIL @ COLUMN ABOVE BULLNOSE ABOVE 4' 0" 3/4'' = V-0" V-4" 1, 1'-4" 4 4 METAL BUILDING COLUMNS 8" CMU (REF EXTERIOR SHALL BE STRAIGHT. TAPERED ELEVATIONS) COLUMNS & INTERIOR COLUMNS REF. REQUIRE WRITTEN APPROVAL. 1/2" GYP BOARD OVER LINER STRUCTURAL MAINTAIN INTERIOR CLEARANCE PANELS - REFER TO INTERIOR COI OF 68'-0" BETWEEN FACE OF ELEVATIONS FOR LOCATIONS COLUMNS ON SALES FLOOR DETAIL IIICOLUMN BELOW BULLNOSE 4 ABOVE 4 -0 3/4 LINE OF FREEZER _ COOLERS BEYOND II II II II 41 ® (FIXTURE PPLIED A y �b INSTALLE I ° IBY DOLLA� GENERAL( IIMERCHANIPISING II ® I IDEPARTM�INT I I� II II II II II II Ip ® II II II II II II II II III CONTRACTIOR TO I 1 (PROVIDE D INSTAL ® 12x4 WHIT DINE GRA 8 I� 12 OR BET R II II I CONTRACTOR TO PROVIDE AND INSTALL 2x6 WHITE PINE GRADE 2 OR BETTER II II II I� � II II II II II II II II II I II II II II II II CONTRACTOR TO11 I INSTALLI �x WOOD I �+ 1 1 FRAMIN TO ALLOW I I HORIZO TAL ANCHI R I BOARD ITO RUN 1 I CONTIN 1OUSLY PANT I PEMB C 1LUMNS II II II II II II �' �' II II II II II II 1 II II II I VERIFY ANCHOR BOARDS LOCATION WITH FIXTURE PLAN 2 ANCHOR BOARD DETAIL NTS T T 3'-0" DOORSTOP 8'-0" WING WALL � (/S�I�M ALUMINUM CORNER GUARDS MOP HOLDER 3'-0" OF 48" HIGH FRP 5'-0" OF 48" HIGH FRP FAUCET THIS WALL MOP SINK (BELOW) WATER HEATER "EWH-2" ON SHELF ABOVE MOP SINK (: ENLARGED PLAN DETAIL SEE 4/P2 ALSO NTS FLOOR PLAN KEYED NOTES RECEIVING DOOR BUZZER (TORK MDL.#TA725 OR EQUAL) 2" DOOR SCOPE 2 (REF DOOR SCHEDULE SHEET A5) WEATHER STRIP & LOW PROFILE THRESHOLD (REF DOOR SCHEDULE SHEET A5) STRIPE FLOOR AT RECEIVING DOOR AS INDICATED FOR DESIGNATED EGRESS PATH (PAINT YELLOW) AND DESIGNATE 3'-0" EMS PANEL CLEARANCE (PAINT RED) STRIPE FLOOR FOR DESIGNATED ADA EGRESS 4A PATH (PAINT YELLOW) PROVIDE AND INSTALL WATER HEATER ABOVE THE MOP SINK (REF 5/A1 AND 3/P1) BEAUTY AND COSMETICS SHELVING AND EQUIPMENT. METAL LINER PANELS COORDINATE FULL HEIGHT PANELS ❑ 7 W/ FURRING @ CMU WEST WALL FOR FLUSH FINISH 8❑ CART AREA. REFER TO 5/A06 WALL OUTLETS FOR BANKS OF COOLERS AND 1-91 FREEZERS AND COSMETICS VALANCE. SEE ELECTRICAL FOR DETAILS. CONCRETE SLAB ON VAPOR BARRIER (REF STRUCTURAL SHEET S2) METAL BUILDING FRAME REFER TO NOTED WALL SECTION FOR ADDITIONAL INFORMATION 1/2" GYP BOARD OVER LINER PANELS W/ R-13 BATT 2 INSULATION. METAL LINER PANELS TO DECK ABOVE; GYPSUM BOARD TO RUN TO 10'-0" AFF, PAINTED. ROOF MOUNTED HVAC UNITS - COORDIANTE PAD 13 DIMENSIONS WITH HVAC UNITS (REF CIVIL PLAN AND SHEET M1) BROOM FINISH CONCRETE SIDEWALK - SLOPE 4 CONCRETE AWAY FROM BUILDING (TYP) - (COORDINATE WITH CIVIL PLANS). F 5 I EIFS PILASTER (REF EXTERIOR ELEVATIONS) ESTOREFRONT SYSTEM (REF SHEETS A5) 1 7 LINE OF CANOPY ABOVE 8 A.D.A. COMPLIANT H.C. RAMP. (REF CIVIL PLANS) CART AND BUMPER GUARDS 4" A.F.F MC CUE PART #9014 TRIMKIT) (REF 5/A6) WALL HYDRANT (REF PLUMBING SHEET P1 20 FOR ADDITIONAL INFORMATION) 21 REFRIGERATION BY DOLLAR GENERAL 22 STEEL COLUMN. PAINT SW7005 PURE WHITE. WRAP STEEL COLUMN WITH TIGHT LOOP CARPET(BLACK) FROM BASE TO 48" A,F.F. 23 POWER POLE. COORDINATE FINAL LOCATION WITH ELECTRICAL DRAWINGS FLOOR ARE AT BASE OF COLUMN WITHIN THE 24 CONSTRUCTION JOINTS TO BE PAINTED BLACK MAGIC TINT ENDCAP COOLER/FREEZER TO BE HARDWIRED THROUGH WHITE SO CORD. GC TO LEAVE BOTTOM 25 HANGING AT 80" AFF. (REF. ELECTRICAL) CORD ANCHORED TO PURLINS ABOVE. COORDINATE LOCATION WITH FINAL DOLLAR GENERAL FIXTURE PLAN. BEAUTY STATION TO BE HARDWIRED THROUGH WHITE SO CORD. GC TO LEAVE BOTTOM HANGING AT 48" 25 AFF. (REF. ELECTRICAL) CORD ANCHORED TO PURLINS ABOVE. COORDINATE LOCATION WITH FINAL DOLLAR GENERAL FIXTURE PLAN. 26 PRE -FINISHED METAL DOWNSPOUTS (COORDINATE SIZE AND LOCATIONS WITH PEMB AND CIVIL PLANS) MC CUE RAILING IN FRONT 'OF�LECTRICAL PANELS 27 8'-0" LONG WITH TOP TWO RAILINGS AND NO MIDDLE POST. 8" SMOOTH -FACED CMU PAINTED (REFER TO EXTERIOR 28 FINISHES ON SHEET A2). ALIGN FACE OF BLOCK WITH STEEL GIRT. PROVIDE PROPER ANCHORAGE TO STRUCTURE. CONSULTANT: SEAL: JOHN BENEDICT POLSINELLI, AR96059 THIS DRAWING SHALL NOT BE USED FOR CONSTRUCTION PURPOSES UNTIL THE SEAL AND SIGNATURE OF THE RESPONSIBLE REGISTRANT APPEARS ON THE DRAWING, AND PROPER PERMIT FORMS AND RELATED FEES ARE TRANSMITTED BY THE OWNER, OWNER'S AGENT OR CONTRACTOR TO THE AUTHORITY HAVING JURISDICTION. DATE ISSUED FOR REV 09/27/201 8 PEMB COORDINATION 11/27/2018 OWNER REVIEW 1 2/18/201 8 PERMIT SUBMITTAL Project Manager Drawn L. LONG B. JACKSON Project Leader Checked L. LONG G. KARANFILOVSKI Date Dept Mgr Approval 08/07/2018 G. KARANFILOVSKI Client PALMETTO ZEPHYRHILLS-20th St, LLC P.O. BOX 161 5 THOMASVILLE, GA 31 792 Office: (229) 226-0682 Contact; John Tate Project DOLLAR GENERAL 38965 CR 54 Zephyrhills, FL 33542 (City of Zephyrhills) Store #: 20360 Drawing Title FLOOR PLAN DO NOT SCALE DRAWING Project No.. Drawing No. JCDT.18.0233 Al k Jk FINISH FLOOR = 0'-0" _ N it EAST ELEVATION Scale: 1/8" = V-0" EXTERIOR FINISHES TAG MATERIAL MANUFACTURER COLOR / STYLE GENERAL REMARKS OEIFS WALL SYSTEM-01 REF PRODUCT APPROVAL ON COVER SHEET COLOR TO MATCH SW #7055 "ENDURING BRONZE" LIT 1,0- FINE OR APPROVED EQUAL BO EIFS WALL SYSTEM-02 REF PRODUCT APPROVAL ON COVER SHEET COLOR TO MATCH SW #6149 "RELAXED KHAKI" LIT 1.0- FINE OR APPROVED EQUAL C� EIFS (CORNICE) REF PRODUCT APPROVAL ON COVER SHEET COLOR TO MATCH SW #6385 "DOVER WHITE" LIT 1.0- FINE OR APPROVED EQUAL pO EIFS (ACCENT BANDING) REF PRODUCT APPROVAL ON COVER SHEET COLOR TO MATCH SW #6385 "DOVER WHITE" LIT 1.0- FINE OR APPROVED EQUAL ODEFS ON CMU REF PRODUCT APPROVAL ON COVER SHEET COLOR TO MATCH SW #7055 "ENDURING BRONZE" O8" SMOOTH FACE CMU REF PRODUCT APPROVAL ON COVER SHEET COLOR TO MATCH SW #6149 "RELAXED KHAKI" OGUTTERS & DOWN SPOUTS PEMB MANUFACTURER LIGHT STONE OSTANDARD METAL ROOF PANELS PEMB MANUFACTURER GALVALUME PBR ROOF PANELS W/ ATLAS ULTIMATE FASTNER JD REAR BUILDING PARAPET WALL PEMB MANUFACTURER LIGHT STONE OSTOREFRONT SYSTEM REF PRODUCT APPROVAL ON COVER SHEET DARK BRONZE L�J PREFINISHED METAL COPING @ PARAPET REF PRODUCT APPROVAL ON COVER SHEET DARK BRONZE ALUMINUM FRAME M HOLLOW METAL DOOR / FRAME REF PRODUCT APPROVAL ON COVER SHEET COLOR TO MATCH SW #7055 "ENDURING BRONZE" LIT 1.0- FINE OR APPROVED EQUAL 0 EAVE STRUT 14'-4" AFF _ \ 00 M CV =fi �r �r FINISH FLOOR Ch = 0'-01, EXTERIOR BUILDING NOTE: ALL EXTERIOR SIGNAGE SHALL BE SUBMITTED UNDER SEPARATE PERMIT NORTH ELEVATION Scale: 1/8" = P-0" SOUTH ELEVATION Scale: 1/8" = V-0" E WEST ELEVATION Scale: 1/8" = V-0" i E KEYED NOTES GC SHALL COORDINATE THE EXTERIOR SIGN WITH DOLLAR GENERAL CORP. GC TO PROVIDE ADEQUATE BLOCKING AS REQUIRED BY SIGN MANUFACTURER TO SUPPORT SIGN WEIGHT (MAX 1,400 LBS). GC TO PROVIDE CIRCUIT AS NOTED ON ELECTRICAL PLAN. SIGN TO BE PROVIDED AND INSTALLED BY DOLLAR GENERAL CORP. INSTALL BUILDING SIGN CENTERED ON FRONT ELEVATION. E l ROOFTOP EQUIPMENT SCREENS BY CITYSCAPES OR EQUAL. COLOR: PUTTY. FLOOD LIGHT. REFER TO ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION. LINE OF PRE -FINISHED METAL ROOF BEYOND (REF EXTERIOR FINISH SCHEDULE THIS SHEET) (4) 1/2" D!A X 6" LG STAINLESS STEEL EYE BOLTS (CLOSED) WITH 1" DIA OPENING - DRILL AND EPDXY INTO BLOCK WALL EXTERIOR RECEPTACLE. RE: ELECTRICAL 1/2" EIFS V-GROOVE (TYP) WALL PACK. REFER TO ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION. �g DOOR BUZZER 10 MECHANICAL VENT - REFER TO MECHANICAL DRAWINGS. > > PLUMBING VENT - REFER TO PLUMBING DRAWINGS.. 12 WALL HYDRANT.. RE: PLUMBING ROOF MOUNTED HVAC UNITS ON PRE FABRICATED ROOF 3 CURB (REF SHEET M1) OUTSIDE AIR TEMP. SENSOR MOUNTED OVER RECEIVING 14 DOORS @ 8'-0" A.F.F. 1 5 EIFS EXPANSION JOINT T/O PARAPET = 19'-2" AFF FINISH FLOOR = 0'-01, 9 PEMB MANUFACTURER SHALL PROVIDE ALL METAL FRAMING, REAR PANELS, CRICKETS, AND REQUIRED FLASHING FOR ANY AND ALL PARTS OF THE RAISED PARAPET AND MASONRY PILASTERS ABOVE THE ROOF LINE - TYP CONSULTANT: SEAL: JOHN BENEDICT POLSINELLI, AR96059 THIS DRAWING SHALL NOT BE USED FOR CONSTRUCTION PURPOSES UNTIL THE SEAL AND SIGNATURE OF THE RESPONSIBLE REGISTRANT APPEARS ON THE DRAWING, AND PROPER PERMIT FORMS AND RELATED FEES ARE TRANSMITTED BY THE OWNER, OWNER'S AGENT OR CONTRACTOR TO THE AUTHORITY HAVING JURISDICTION, DATE ISSUED FOR REV 09/27/201 8 PEMB COORDINATION 11/27/2018 OWNER REVIEW 1 2/1 8/201 8 PERMIT SUBMITTAL Project Manager Drawn L. LONG B. JACKSON Project Leader Checked L. LONG G. KARANFILOVSKI Date Dept Mgr Approval 08/07/2018 G. KARANFILOVSKI Client PALMETTO ZEPHYRHILLS-20th St, LLC P.O. BOX 1615 THOMASVILLE, GA 31 792 Office: (229) 226-0682 Contact: John Tate Project DOLLAR GENERAL 38965 CR 54 Zephyrhills, FL 33542 (City of Zephyrhills) Store #: 20360 Drawing Title EXTERIOR ELEVATIONS DO NOT SCALE DRAWING Project No. Drawing No.. JC DT.18.0233 A2 2 .WALL SECTION 3 21 8 I I I 20 10 A EMB ALL J 0 1/2" 1 1/2" ,! 18 22 3 WALL SECTION GENERALC SHALL COO DUCT PENE 23 PEMB AND 1 DRAWINGS .l 35 31 36 v 24 9 31 v 29 U o v 25 N CONC SIDEWAI AWAY FROM BI (REF CIVIL) 4 .WALL SECTION 5 WALL SECTION KEYED NOTES ZPRE-ENGINEERED METAL BUILDING SYSTEM (BY PREFAB BUILDING MANUFACTURER) MINIMUM R-19 VINYL BACKED INSULATION + R-11 LINER SYSTEM WITH R-5 THERMAL BLOCKS AT EACH PURLIN (BY PEMB). INSULATION TO BE PULLED TIGHT. STANDING SEAM METAL ROOF - GALVALUME FINISH (BY PREFAB BUILDING MANUFACTURER) ROOF MOUNTED HVAC UNIT (REF MECHANICAL) VINYL FACED R-13 BATT INSULATION + R-6.5 CONTINUOUS INSULATION (BY PEMB). 6� METAL BUILDING GIRT (BY PEMB). �7 VERTICAL METAL LINER PANELS.. 1/2" GYP BOARD OVER LINER PANELS W/ R-13 BATT INSULATION. METAL LINER PANELS TO DECK ABOVE; GYPSUM BOARD TO RUN TO 10'-0" AFF, PAINTED. aPRE -FINISHED DOWNSPOUT & GUTTER (BY PRE-ENGINEERED BUILDING MANUFACTURER) GC SHALL COORDINATE WITH PRE-ENGINEERED METAL BUILDING MANUFACTURER AND PROVIDE 10 ALL METAL CLOSURE, SEALANT, AND CAULKING TO WATERTIGHT FINISH. INCLUDING ALL ROOF SCUPPER LOCATIONS. LOCATION OF 1 1/2" CONDUIT WITH PULLSTRING 1 1 (ABOVE OFFICE) FOR SATELLITE LINE. PROVIDE WEATHERTIGHT SEAL AT HORIZONTAL PARAPET PENETRATION. CONTRACTOR RESPONSIBLE FOR INSTALLATION OF CONDUIT. 12 1/2" MINIMUM GYPSUM BOARD ON 3 5/8"x20ga MTL STUDS TO U/S STRUCTURE ABOVE 13 ADA COMPLIANT DRINKING FOUNTAIN, REFER TO PLUMBING. 14 CABLE TRAY SYSTEM (REF SHEET A9) 1 5 METAL BUILDING COLUMNS SHALL BE STRAIGHT. TAPERED COLUMNS & INTERIOR COLUMNS REQUIRE WRITTEN APPROVAL. HOLD INTERIOR CLEARANCE BETWEEN FACE OF COLUMNS ON SALES FLOOR. 16 CONC SLAB ON VINYL VAPOR BARRIER (REF STRUCTURAL) ❑STOREFRONT SYSTEM AS SCHEDULED - COORDINATE 1 WITH FLORIDA PRODUCT APPROVAL INSTALLATION GUIDELINES (REF SHEET A5) 18 UNDISTURBED EARTH AND COMPACTED SUB GRADE (REF STRUCTURAL AND GEOTECH REPORT) 19 PRE -FINISHED METAL SOFFIT (BY PEMB). 20 PRE -FINISHED METAL WALL PANELS. 21 PREPARED GRANNULAR FILL (REF STRUCTURAL) 22 REINFORCED CONCRETE FOOTING (REF STRUCTURAL) 23 PREFINISHED METAL COPING BY PEMB (COORDINATE PROFILE W/ CORNICE AND PILASTER LOCATIONS) 24 EXTERIOR BUILDING SIGN (BY DOLLAR GENERAL) 25 FINISH GRADE AT EXTERIOR WALLS SHALL BE A MINIMUM OF 3" BELOW FINISHED FLOOR AT ALL PAVED AREAS AND A MINIMUM OF 6" BELOW FINISHED FLOOR AT ALL NON PAVED AREAS. (REF CIVIL DRAWINGS) 26 UNDER SOFFIT LIGHTING (REF ELECTRICAL) 27 COORDINATE DOWNSPOUT CONNECTIONS TO UNDERGROUND STORM LINE WITH CIVIL DRAWINGS. 28 INTERIOR WALL PAINTED (REF INTERIOR ROOM FINISH SCHEDULE) 29 8" SMOOTH FACE CMU. ALIGN FACE OF BLOCK WITH STEEL GIRT. PROVIDE PROPER ANCHORAGE TO STRUCTURE. (REF EXTERIOR ELEVATIONS) 30 MC CUE TRIM KIT, ORDER KIT "E". 31 EIFS SYSTEM OVER EXTERIOR GRADE GYPSUM ON METAL WALL PANELS (REF EXTERIOR ELEVATIONS) 32 METAL COLUMN, WRAP WITH CARPET UP TO 48" AF.F. 33 V X 4' LIGHT FIXTURES HUNG WITH AIRCRAFT CABLE. ADD UNISTRUT TO PURLINS AS REQUIRED FOR HANGING 34 DEFS ON 8" CMU 35 EIFS CORNICE ON EXTERIOR GRADE GYPSUM ON METAL WALL PANELS (REF EXTERIOR ELEVATIONS) 36 COORDINATE WITH SIGN VENDOR (REF SIGN BRACING DETAILS ON SHEET A8) 37 DEFS ON 4" CMU PILASTER 38 EIFS V-GROOVE 39 EIFS EXPANSION JOINT CONSULTANT: SEAL: JOHN BENEDICT POLSINELLI, AR96059 THIS DRAWING SHALL NOT BE USED FOR CONSTRUCTION PURPOSES UNTIL THE SEAL AND SIGNATURE OF THE RESPONSIBLE REGISTRANT APPEARS ON THE DRAWING, AND PROPER PERMIT FORMS AND RELATED FEES ARE TRANSMITTED BY THE OWNER, OWNER'S AGENT OR CONTRACTOR TO THE AUTHORITY HAVING JURISDICTION. DATE ISSUED FOR REV 09/27/201 8 PEMB COORDINATION 1 1 /27/201 8 OWNER REVIEW 12/1 8/201 8 PERMIT SUBMITTAL Project Manager Drawn L. LONG B. JACKSON Project Leader Checked L. LONG G. KARANFILOVSKI Date Dept Mgr Approval 08/07/201 8 G. KARANFILOVSKI Client PALMETTO ZEPHYRHILLS-20th St, LLC P.O. BOX 1615 THOMASVILLE, GA 31 792 Office: (229) 226-0682 Contact: John Tate Project DOLLAR GENERAL 38965 CR 54 Zephyrhills, FL 33542 (City of Zephyrhills) Store #: 20360 Drawing Title SECTIONS AND DETAILS DO NOT SCALE DRAWING Project No. Drawing No. .JCDT.18.02 3 3 A3 11 1 0 C/0-1..7A.-... 11AGTA1 8" 8" j iI1 N 31 FIRE STOP SEALANT 8 15 I` 1 (BOTH SIDES) III - 1 13§ EN H 'ilii 2 �, ; FIRE RATED..., D l INSULATION ao �' 6 I 31 `` 5 Jill _ K / X 7 i .... I NOTE: APPLY FIRE 8 �I' STOP SEALANT (EACH 3 I \ E.;.. 24 SIDE) FROM FINISHED FLOOR TO 4'-0" AFF AT 3 5/8"x20ga METAL DEFS ON 4" 4 — — — — — — — — — — — — — — — — 10 \ CMU WALL. STUDS @ 16" O.C. CMU PILASTER 29 5/8" TYPE "X" GYPSUM s 1'-0" BOARD 2,-$ (9) ENLARGED PLAN DETAI ENLARGED PLAN DETAIL SCALE 1" = V-0" PARAPET CORNICE DETAIL SCALE: I" = P-0" 1 i 3 5/8"x20ga METAL i STOREFRONT PEMB STUDS @ 16" O.C. �� SYSTEM AS ✓ SCHEDULED - COORDINATE mini i a 0�i COORDINATE WITH $ FLORIDA PRODUCT T APPROVAL INSTALLATION "r z GUIDELINES o 1 WALL SECTION Scale: 1/2" = V-0" r — — — Py — — — — — — — — — 10'-8" HIGH CMU TO COLUMN LINE 2 W / SHIM AND SEALANT ---------- EACH SIDE OF STOREFRONT PERIMETER (TYP) STORE FRONT JAMB DETAIL SALE 1" = V-0" NOTE: CONTRACTOR TO PRQVIDE COPING ATTACHMENT DETAIL PER FBC 2017 NOTE: ALL PLYWOOD USED IN EXTERIOR WALLS TO BE FIRE RETARDANT TREATED PARAPET CORNICE DETAIL SCALE: 1" = V-0" REFER TO STRUCTURAL DRAWINGS FOR CMU THIS AREA REFER TO STRUCTURAL DRAWINGS FOR REINF. AND GROUTING INFORMATION 8" CMU COLL COVER AS SCHEDULED STEEL COLUMN BY PEMB LINE OF CANOPY ABOVE MASONRY COLUMN DETAIL SALE 1" = V-0" 12 HSS BEAM. REFER TO STRUCTURAL DRAWINGS. PROVIDE 1/4" SHIM AND SEALANT W/ BACKER ROD (TYP AT PERIMETER) CLEAR GLASS TRANSOM. STOREFRONT SYSTEM AS SCHEDULED - COORDINATE WITH FLORIDA PRODUCT APPROVAL INSTALLATION GUIDELINES ELASTOMERIC MEMBRANE BETWEEN STEEL TUBE AND ALUMIMUV BREAK METAL PRE -FINISHED ALUMIMUM BREAK METAL TO MATCH STOREFRONT SYSTEM Y T-8" AFF HSS BEAM. REFER TO STRUCTURAL DRAWINGS. — PROVIDE 1/4" SHIM AND SEALANT W/ BACKER ROD (TYP AT PERIMETER) - AUTOMATIC DOOR SYSTEM AS SCHEDULED - COORDINATE WITH FLORIDA PRODUCT APPROVAL INSTALLATION GUIDELINES 5 1%4 0 v T n ��0 STORE FRONT HEAD DETAIL SCALE: 1" = V-0" 19 LINE OF CANOPY ABOVE T.O.S. WALL SECTION! 0 PILASTER SCALE: 1" = P-0" KEYED NOTES PRE-ENGINEERED METAL BUILDING SYSTEM (BY PREFAB BUILDING MANUFACTURER) MINIMUM R-19 VINYL BACKED INSULATION + R-11 LINER SYSTEM WITH R-5 THERMAL BLOCKS AT EACH PURLIN (BY PEMB). INSULATION TO BE PULLED TIGHT. STANDING SEAM METAL ROOF - GALVALUME FINISH (BY PREFAB BUILDING MANUFACTURER) ROOF MOUNTED HVAC UNIT (REF MECHANICAL) VINYL FACED R-13 BATT INSULATION + R-6.5 CONTINUOUS INSULATION (BY PEMB). 6] METAL BUILDING GIRT (BY PEMB). �7 VERTICAL METAL LINER PANELS. 1/2" GYP BOARD OVER LINER PANELS W/ R-13 BATT INSULATION. METAL LINER PANELS TO DECK ABOVE; GYPSUM BOARD TO RUN TO 10'-0" AFF, PAINTED. PRE -FINISHED DOWNSPOUT & GUTTER (BY PRE-ENGINEERED BUILDING MANUFACTURER) GC SHALL COORDINATE WITH PRE-ENGINEERED 11-01 METAL BUILDING MANUFACTURER AND PROVIDE ALL METAL CLOSURE, SEALANT, AND CAULKING TO WEATHERTIGHT FINISH 11 LOCATION OF 1 1/2" CONDUIT WITH PULLSTRING (ABOVE OFFICE) FOR SATELLITE LINE. PROVIDE WEATHERTIGHT SEAL AT HORIZONTAL PARAPET PENETRATION. CONTRACTOR RESPONSIBLE FOR INSTALLATION OF CONDUIT. 12 1/2" MINIMUM GYPSUM BOARD ON 3 5/8"x20ga MTL STUDS TO U/S STRUCTURE ABOVE 1 3 ADA COMPLIANT DRINKING FOUNTAIN, REFER TO PLUMBING. 14 CABLE TRAY SYSTEM WITH WHITE LINER (REF A9) 1 5 METAL BUILDING COLUMNS SHALL BE STRAIGHT. TAPERED COLUMNS & INTERIOR COLUMNS REQUIRE WRITTEN APPROVAL. HOLD INTERIOR CLEARANCE BETWEEN FACE OF COLUMNS ON SALES FLOOR. 16 CONC SLAB ON VINYL VAPOR BARRIER E (REF STRUCTURAL) STOREFRONT SYSTEM AS SCHEDULED - COORDINATE 1 7 WITH FLORIDA PRODUCT APPROVAL INSTALLATION GUIDELINES (REF SHEET A5) 18 UNDISTURBED EARTH AND COMPACTED SUB GRADE (REF STRUCTURAL AND GEOTECH REPORT) 19 PRE -FINISHED METAL SOFFIT (BY PEMB). ZD PRE -FINISHED METAL WALL PANELS. 21 PREPARED GRANNULAR FILL (REF STRUCTURAL) 22 REINFORCED CONCRETE FOOTING H (REF STRUCTURAL) 23 PREFINISHED METAL COPING BY PEMB (COORDINATE PROFILE W/ CORNICE AND PILASTER LOCATIONS) 24 EXTERIOR BUILDING SIGN (BY DOLLAR GENERAL) 25 FINISH GRADE AT EXTERIOR WALLS SHALL BE A MINIMUM OF 3" BELOW FINISHED FLOOR AT ALL PAVED AREAS AND A MINIMUM OF 6" BELOW FINISHED FLOOR AT ALL NON PAVED AREAS. (REF CIVIL DRAWINGS) 26 UNDER SOFFIT LIGHTING (REF ELECTRICAL) 27 EIFS SYSTEM OVER SMOOTH FACE CMU. ALIGN FACE OF CMU WITH STEEL GIRT. (REF EXTERIOR ELEVATIONS) 28 INTERIOR WALL PAINTED R (REF INTERIOR ROOM FINISH SCHEDULE) 29 8" SMOOTH FACE CMU. ALIGN FACE OF BLOCK WITH STEEL GIRT. PROVIDE PROPER ANCHORAGE TO STRUCTURE. (REF EXTERIOR ELEVATIONS) 30 MC CUE TRIM KIT, ORDER KIT "E". 31 EIFS SYSTEM OVER EXTERIOR GRADE GYPSUM ON METAL WALL PANELS (REF EXTERIOR ELEVATIONS) 32 METAL COLUMN, WRAP WITH CARPET UP TO 48" AF.F. 33 V X 4' LIGHT FIXTURES HUNG WITH AIRCRAFT H CABLE.. ADD UNISTRUT TO PURLINS AS REQUIRED FOR HANGING 34 DEF$ ON 8" CMU 35 EIFS CORNICE ON EXTERIOR GRADE GYPSUM (REF EXTERIOR ELEVATIONS) - COORDINATE WITH SIGN VENDOR (REF SIGN BRACING DETAILS ON SHEET A8) 37 DEFS ON 4" CMU PILASTER 38 EIFS V-GROOVE 39 EIFS EXPANSION JOINT CONSULTANT: SEAL: JOHN BENEDICT POLSINELLI, AR96059 THIS DRAWING SHALL NOT BE USED FOR CONSTRUCTION PURPOSES UNTIL THE SEAL AND SIGNATURE OF THE RESPONSIBLE REGISTRANT APPEARS ON THE DRAWING, AND PROPER PERMIT FORMS AND RELATED FEES ARE TRANSMITTED BY THE OWNER, OWNER'S AGENT OR CONTRACTOR TO THE AUTHORITY HAVING JURISDICTION. DATE ISSUED FOR REV 09/27/201 8 PEMB COORDINATION 1 1 /27/201 8 OWNER REVIEW 12/18/2018 PERMIT SUBMITTAL Project Manager Drawn L. LONG B. JACKSON Project Leader Checked L. LONG G. KARANFILOVSKI Date Dept Mgr Approval 08/07/201 8 G. KARANFILOVSKI Client PALMETTO ZEPHYRHILLS-20th St, LLC P.O. BOX 1615 THOMASVILLE, GA 31 792 Office: (229) 226-0682 Contact: John Tate Project DOLLAR GENERAL 38965 CR 54 Zephyrhills, FL 33542 (City of Zephyrhills) Store #: 20360 Drawing Title SECTIONS AND DETAILS DO NOT SCALE DRAWING Project No. Drawing No. �CDTA .0233 A3a VINYL FACE INSUL SCHEDULED BY PE STEEL CHANNEL B' STRUCTURAL DRA ATTACHMENT TO 8" 4" MASONRY PILASTER COI CONT BACKER ROD AND ON AIRSPACE SEALANT EACH SIDE OFx xi, (REF EXTERIOR 2'-8 PILASTER (COLOR TO It METAL LINER PANEL ELEVATIONS) 4" ! 2'-4" MATCH EIFS) - TYP ADJUSTABLE MASONRY WALL TIES AT 24"oe VERT COI ter'" MET LINER PANEL ----------- — — — — --- ---- JUST A LE MASONRY WA TIES T 24"oc VERT co 4" ! 2'-4" 8" CMU (REF CONT BACKER ROD AND I 4" MASONRY PILASTER I EXTERIOR SEALANT EACH SIDE OF 2 -8 f\ ON AIRSPACE 3 - ELEVATIONS) PILASTER (COLOR TO (REF EXTERIOR MATCH EIFS) - TYP L. ELEVATIONS) COI ENLARGED PLAN DETAIL AT CMU 4 DETAIL Scale: 3" = V-0" DETAIL Scale: 3" = V-0" Scale: 3/4" = V-0" ENLARGED PLAN DETAIL AT CMU 2 WALL SECTION Scale: 3/4" = V-0" 8" CMU (REF EXTERIOR ELEVATIONS) 1 WALL SECTION @ PILASTER Scale; 1/2" = V-0" KEYED NOTES PRE-ENGINEERED METAL BUILDING SYSTEM (BY PREFAB BUILDING MANUFACTURER) MINIMUM R-19 VINYL BACKED INSULATION + R-11 LINER SYSTEM WITH R-5 THERMAL BLOCKS AT EACH PURLIN (BY PEMB). INSULATION TO BE PULLED TIGHT. FflSTANDING SEAM METAL ROOF - GALVALUME FINISH (BY PREFAB BUILDING MANUFACTURER) ROOF MOUNTED HVAC UNIT (REF MECHANICAL) EVINYL FACED R-13 BATT INSULATION + R-6.5 CONTINUOUS INSULATION (BY PEMB). 6� METAL BUILDING GIRT (BY PEMB). VERTICAL METAL LINER PANELS. 1/2" GYP BOARD OVER LINER PANELS W/ R-13 BATT INSULATION. METAL LINER PANELS TO DECK ABOVE; GYPSUM BOARD TO RUN TO 10'-0" AFF, PAINTED. PRE -FINISHED DOWNSPOUT & GUTTER (BY PRE-ENGINEERED BUILDING MANUFACTURER) GC SHALL COORDINATE WITH PRE-ENGINEERED METAL BUILDING MANUFACTURER AND PROVIDE ALL METAL CLOSURE, SEALANT, AND CAULKING TO WEATHERTIGHT FINISH � � LOCATION OF 1 1/2" CONDUIT WITH PULLSTRING (ABOVE OFFICE) FOR SATELLITE LINE. PROVIDE WEATHERTIGHT SEAL AT HORIZONTAL PARAPET PENETRATION. CONTRACTOR RESPONSIBLE FOR INSTALLATION OF CONDUIT. Z 1/2" MINIMUM GYPSUM BOARD ON 3 5/8"x20ga MTL STUDS TO U/S STRUCTURE ABOVE 3 ADA COMPLIANT DRINKING FOUNTAIN, REFER TO PLUMBING. 14 CABLE TRAY SYSTEM WITH WHITE LINER (REF A9) 5 METAL BUILDING COLUMNS SHALL BE STRAIGHT. TAPERED COLUMNS & INTERIOR COLUMNS REQUIRE WRITTEN APPROVAL. HOLD INTERIOR CLEARANCE BETWEEN FACE OF COLUMNS ON SALES FLOOR. HCONC SLAB ON VINYL VAPOR BARRIER (REF STRUCTURAL) STOREFRONT SYSTEM AS SCHEDULED - COORDINATE 7 WITH FLORIDA PRODUCT APPROVAL INSTALLATION GUIDELINES (REF SHEET A5) UNDISTURBED EARTH AND COMPACTED SUB GRADE (REF STRUCTURAL AND GEOTECH REPORT) 19 PRE -FINISHED METAL SOFFIT (BY PEMB). 20 PRE -FINISHED METAL WALL PANELS. 21 PREPARED GRANNULAR FILL (REF STRUCTURAL) 22 REINFORCED CONCRETE FOOTING (REF STRUCTURAL) 23 PREFINISHED METAL COPING BY PEMB (COORDINATE PROFILE W/ CORNICE AND PILASTER LOCATIONS) z4 EXTERIOR BUILDING SIGN (BY DOLLAR GENERAL) 25 FINISH GRADE AT EXTERIOR WALLS SHALL BE A MINIMUM OF 3" BELOW FINISHED FLOOR AT ALL PAVED AREAS AND A MINIMUM OF 6" BELOW FINISHED FLOOR AT ALL NON PAVED AREAS. (REF CIVIL DRAWINGS) 26 UNDER SOFFIT LIGHTING (REF ELECTRICAL) 27 EIFS SYSTEM OVER SMOOTH FACE CMU. ALIGN FACE OF CMU WITH STEEL GIRT, (REF EXTERIOR ELEVATIONS) H28 INTERIOR WALL PAINTED (REF INTERIOR ROOM FINISH SCHEDULE) 29 8" SMOOTH FACE CMU. ALIGN FACE OF BLOCK WITH STEEL GIRT. PROVIDE PROPER ANCHORAGE TO STRUCTURE. (REF EXTERIOR ELEVATIONS) 30 MC CUE TRIM KIT, ORDER KIT "E". 31 EIFS SYSTEM OVER EXTERIOR GRADE GYPSUM ON METAL WALL PANELS (REF EXTERIOR ELEVATIONS) 32 METAL COLUMN, WRAP WITH CARPET UP TO 48" AF.F. 33 V X 4' LIGHT FIXTURES HUNG WITH AIRCRAFT CABLE. ADD UNISTRUT TO PURLINS AS REQUIRED FOR HANGING 34 DEFS ON 8" CMU 35 EIFS CORNICE ON EXTERIOR GRADE GYPSUM (REF EXTERIOR ELEVATIONS) 36 COORDINATE WITH SIGN VENDOR (REF SIGN BRACING DETAILS ON SHEET A8) 37 DEFS ON 4" CMU PILASTER 3$ EIFS V-GROOVE 39 EIFS EXPANSION JOINT CONSULTANT: SEAL: JOHN BENEDICT POLSINELLI, AR96059 THIS DRAWING SHALL NOT BE USED FOR CONSTRUCTION PURPOSES UNTIL THE SEAL AND SIGNATURE OF THE RESPONSIBLE REGISTRANT APPEARS ON THE DRAWING, AND PROPER PERMIT FORMS AND RELATED FEES ARE TRANSMITTED BY THE OWNER, OWNER'S AGENT OR CONTRACTOR TO THE AUTHORITY HAVING JURISDICTION. DATE ISSUED FOR REV 09/27/201 8 PEMB COORDINATION 1 1 /27/201 8 OWNER REVIEW 12/1 8/2018 PERMIT SUBMITTAL Project Manager Drawn L. LONG B. JACKSON Project Leader Checked L. LONG G. KARANFILOVSKI Date Dept Mgr Approval 08/07/2018 G. KARANFILOVSKI Client PALMETTO ZEPHYRHILLS-20th St, LLC P.O. BOX 16115 THOMASVILLE, GA 31 792 Office: (229) 226-0682 Contact: John Tate Project DOLLAR, GENERAL 38965 CR 54 Zephyrhills, FL 33542 (City of Zephyrhills) Store #: 20360 Drawing Title SECTIONS AND DETAILS DO NOT SCALE DRAWING Project No. Drawing No. JCDT.18.0233 A3b ROOM SCHEDULE FLOOR BASE A WALL B WALL C WALL D WALL CEILING CEILING MATERIAL FINISH MATERIAL FINISH MATERIAL FINISH MATERIAL FINISH MATERIAL FINISH MATERIAL FINISH NO ROOM NAME MATERIAL FINISH REMARKS CONCRETE CONCRETE 4" RUBBER / BLACK GYPSUM BOARD SHERWIN WILLIAMS - , GYPSUM BOARD SHERWIN WILLIAMS - GYPSUM BOARD SHERWIN WILLIAMS - GYPSUM BOARD SHERWIN WILLIAMS - 2'X4' ACOUSTICAL WHITE 100 BREAK RM FLOOR SEALED WITH SEALER VINYL BASE TO 10'-0" AFF ON PRO -MAR LATEX TO 10'-0" AFF, SW7005-PURE WHITE, TO 10'-0" AFF SW7005-PURE WHITE, TO 10'-0" AFF SW7005-PURE WHITE, CEILING 8'-0" A.F.F. (STEPS 1-3) MTL STUDS TO SEMI -GLOSS. WHITE METAL PRO -MAR LATEX PRO -MAR LATEX PRO -MAR LATEX UNDERSIDE OF LINER PANELS SEMI -GLOSS. SEMI -GLOSS. SEMI -GLOSS. DECK ABOVE. ABOVE CONCRETE CONCRETE 4" RUBBER/ BLACK GYPSUM BOARD SHERWIN WILLIAMS - GYPSUM BOARD SHERWIN WILLIAMS - GYPSUM BOARD SHERWIN WILLIAMS - GYPSUM BOARD SHERWIN WILLIAMS - 2'X4' ACOUSTICAL WHITE 101 OFFICE FLOOR SEALED WITH SEALER VINYL BASE TO 10'-0" AFF SW7005-PURE WHITE, TO 10'-0" AFF, SW7005-PURE WHITE, TO 10'-0" AFF SW7005-PURE WHITE, TO 10'-0" AFF SW7005-PURE WHITE, CEILING 8'-0" A.F.F. (STEPS 1-3) PRO -MAR LATEX WHITE METAL PRO -MAR LATEX PRO -MAR LATEX PRO -MAR LATEX SEMI -GLOSS. LINER PANELS SEMI -GLOSS. SEMI -GLOSS. SEMI -GLOSS. ABOVE CONCRETE POLISHED 4 RUBBER/ BLACK GYP BOARD TO SEE 1/A4 FOR FINISH GYPSUM BOARD SEE 1/A4 FOR FINISH GYP BOARD TO SEE 1/A4 FOR FINISH GYPSUM BOARD SEE 1/A4 FOR FINISH EXPOSED TO EXPOSED TO REFER TO FINISH 102 SALES AREA FLOOR POLISHED CONCRETE VINYL BASE 10'-0" A.F.F. ON PAINT LOCATIONS PER HEIGHT PAINT LOCATIONS 10'-0" A.F.F. ON PAINT LOCATIONS TO ROOF DECK PAINT LOCATIONS STRUCTURE STRUCTURE PLAN 1/A4 FOR WITH SEALER WHITE METAL NOTED ON WALL WHITE METAL ABOVE ABOVE ADDITIONAL (STEPS 1-8) LINER PANELS ELEVATIONS LINER PANELS NOTES CONCRETE CONCRETE N/A N/A METAL LINER LIGHT STONE. GYPSUM BOARD LIGHT STONE METAL LINER TAPED. PAINTED AS METAL LINER TAPED. PAINTED AS EXPOSED TO N/A 103 RECEIVING AREA FLOOR SEALED WITH SEALER PANEL ABOVE CMU PAINT CMU SW#6149 TO U/S OF DECK PANEL TO 8'-0" AFF REQUIRED BY CODE. PANEL TO 8'-0" AFF REQUIRED BY CODE. STRUCTURE (STEPS 1-3) ABOVE MTL, LINER PANEL TO MTL.. LINER PANEL TO ABOVE DECK AS ALTERNATE. DECK AS ALTERNATE. CONCRETE SHERWIN WILLIAMS 8'-0" HIGH FIBERGLASS GYPSUM BOARD 8'-0" HIGH FIBERGLASS GYPSUM BOARD 8'-0" HIGH FIBERGLASS GYPSUM BOARD 8'-0" HIGH FIBERGLASS 2' X 4' WHITE 104 GENDER FLOOR SEALED ACRYLIC SILICONE 4�� RUBBER/ BLACK GYPSUM BOARD REINFORCED PANEL - TO 8'-0" AFF REINFORCED PANEL - TO 8'-0" AFF REINFORCED PANEL - TO 8'-0" AFF REINFORCED PANEL - GYP BD OR ACT NEUTRAL SILK CHOCOLATE VINYL BASE TO 8'-0" AFF "WHITE" "WHITE" "WHITE" "WHITE" CEILING HC-117 (STEPS 1-3) 8'-0" A.F.F. CONCRETE SHERWIN WILLIAMS 8'-0" HIGH FIBERGLASS GYPSUM BOARD 8'-0" HIGH FIBERGLASS GYPSUM BOARD 8'-0" HIGH FIBERGLASS GYPSUM BOARD 8'-0" HIGH FIBERGLASS 2' X 4' WHITE 105 GENDER FLOOR SEALED ACRYLIC SILICONE 4" RUBBER/ BLACK GYPSUM BOARD REINFORCED PANEL - TO 8'-0" AFF REINFORCED PANEL - TO 8'-0" AFF REINFORCED PANEL - TO 8'-0" AFF REINFORCED PANEL - GYP BD OR ACT NEUTRAL SILK CHOCOLATE VINYL BASE TO 8'-0" AFF "WHITE" "WHITE" "WHITE" "WHITE" CEILING @ HC-117 (STEPS 1-3) 8'-0" A.F.F. CONCRETE POLISHED SHERWIN WILLIAMS - GYPSUM BOARD SHERWIN WILLIAMS - GYPSUM BOARD SHERWIN WILLIAMS - GYPSUM BOARD SHERWIN WILLIAMS - 2 X 4 ACOUSTICAL WHITE 107 HALLWAY FLOOR SEALED CONCRETE WITH 4�� RUBBER/ BLACK GYPSUM BOARD SW6991 BLACK MAGIC, TO 8'-0" AFF SW6991 BLACK MAGIC, TO 8'-0" AFF SW6991 BLACK MAGIC, TO 8'-0" A.F.F. ON SW7005 PURE WHITE, CEILING @ 8'-0" SEALER (STEPS 1-9) VINYL BASE TO 8'-0" AFF PRO -MAR LATEX PRO -MAR LATEX PRO -MAR LATEX BULKHEAD PRO -MAR LATEX SEMI- A.F.F. SEMI -GLOSS TO 48" SEMI -GLOSS TO 48" SEMI -GLOSS TO 48" GLOSS ABOVE 48" AFF. SHERWIN AFF. AFF. AFF. WILLIAMS - SW7005 SHERWIN WILLIAMS - SHERWIN WILLIAMS - PURE WHITE, SW7005 PURE WHITE, SW7005 PURE WHITE, PRO -MAR LATEX SEMI- PRO -MAR LATEX SEMI- PRO -MAR LATEX SEMI- GLOSS ABOVE 48" GLOSS ABOVE 48" GLOSS ABOVE 48" AFF. 1AFF. 1AFF. NOTE: ALL ALL PAINTED WALLS TO BE PRIMED FIRST, THEN PAINTED INTERIOR PAINT SCHEME: DOLLAR GENERAL TRADITIONAL (E) NOTE: ALL DOORS & DOOR FRAMES INSIDE SALES AREA (EXCLUDING MAIN STOREFRONT ENTRANCE & RELATED GLAZING) SHALL BE PAINTED SW 6991 "BLACK MAGIC" FLOOR FINISH LOCATION PLAN Scale: 1/16" = V-0" NORTH PRE -FINISHED METAL LINER PANELS TO UNDERSIDE OF DECK ABOVE — — — — — — — — T — — — — — — — — . ////////,•-r/////////ter///////.'.� ELEVATION 'A' U C? 0 0 TRANSFER GRILLE - REF. MECHANICAL DRAWINGS TO 48" A.F.F. P - 26'-8" ELEVATION 'B' 1 ELEVATION 'C' ELEVATION 'D' PEMB FRAMING, PAINT TO MATCH ADJACENT WALL — PRE -FINISHED METAL LINER PANELS TO UNDERSIDE OF DECK ABOVE � NINE O O Pi PRE -FINISHED METAL LINER PANELS PEMB FRAMING, PAINT TO P1 TO UNDERSIDE OF DECK ABOVE MATCH ADJACENT WALL 25'-0" Q 12'-0" Scale: 1/8" = P-0" ; 10'-0" WALL PAINT LEGEND p ; I SW6910 "DAISY" p2 SW6991 "BLACK MAGIC" r?31 SW7005 "PURE WHITE" pq EXPOSED LINER PANEL P5 DENOTES GYPSUM BOARD, TAPED AND MUDDED ONLY NOTE: PAINT EXPOSED STRUCTURE SW7005 PURE WHITE CONSULTANT: SEAL: JOHN BENEDICT POLSINELLI, AR96059 THIS DRAWING SHALL NOT BE USED FOR CONSTRUCTION PURPOSES UNTIL THE SEAL AND SIGNATURE OF THE RESPONSIBLE REGISTRANT APPEARS ON THE DRAWING, AND PROPER PERMIT FORMS AND RELATED FEES ARE TRANSMITTED BY THE OWNER, OWNER'S AGENT OR CONTRACTOR TO THE AUTHORITY HAVING JURISDICTION. DATE ISSUED FOR REV 09/27/201 8 PEMB COORDINATION 11/27/2018 OWNER REVIEW 12/1 8/2018 PERMIT SUBMITTAL Project Manager Drawn L. LONG B. JACKSON Project Leader Checked L. LONG G. KARANFILOVSKI Date Dept Mgr Approval 08/07/2018 G. KARANFILOVSKI Client PALMETTO ZEPHYRHILLS-20th St, LLC P.O. BOX 1615 THOMASVILLE, GA 31 792 Office: (229) 226-0682 Contact: John Tate Project DOLLAR GENERAL 38965 CR 54 Zephyrhills, FL 33542 (City of Zephyrhills) Store #,t: 20360 Drawing Title ROOM FINISH SCHEDULE AND SALES FLOOR ELEVATIONS DO NOT SCALE DRAWING Project No. Drawing No. JCDTA 8.0233 A4 DOOR SCHEDULE DOOR WIDTH HEIGHT THICKNESS NO. Type DOOR HARDWARE REMARKS 100 A 3' — 0" 7' - 0" 1 3/4" 1-1/2 PAIR HINGES 1 STANLEY PASSAGE LOCKSET CL230—E-626-S4 — NO KEY REQUIRED, 1 STANLEY DOOR CLOSER DC311-689 1 IVES WALL STOP #402-1/2B-26D ( ) ,O Q Q ,O Q ,O SOLID CORE WOOD DOOR OR HOLLOW CORE METAL DOOR PAINTED INTERIOR SIDE OF ALL DOORS AND FRAME TO BE SW6991, "BLACK MAGIC" (SEMI —GLOSS). 101 B 1 _ „ 3 0 1 _ „ 7 0 1 3/4 „ 1-1/2 PAIR HINGES 1 STANLEY STOREROOM LOCKSET QCL270—E-626-S4-SC-KD — KEY #1 1 STANLEY DOOR CLOSER QD 311-689 1 IVES WALL STOP #402-1/2B-2 D ( ) � O C � O � O , SOLID WOOD DOOR OR HOLLOW CORE METAL DOOR PAINTED (1) TACO DOOR VIEWER #TA3310PC. SW6991, "BLACK MAGIC" (SEMI -GLOSS) - BOTH DOOR & DOOR FRAME. 102 E 3' - 0" 7' - 0" 1 3/4" (1-1/2) PAIR HINGES, (1) VON DUPRIN GUARD-X EXIT ALARM LOCK #2670-28, HOLLOW CORE INSULATED METAL DOOR. SEE SHEET A2 FOR EXTERIOR PAINT; (1) STANLEY DOOR CLOSER QDC311-689, (1) DOOR PULL 8N US28, (1) DOOR SWEEP, WEATHERSTRIPPING, (1) 7015SC8-26D—RIM CYLINDER PAINT INTERIOR SW6991, "BLACK MAGIC" — DOOR & FRAME. 103A D 6 — 0 7 — 0 1 3/4 3 PAIR HINGES COMPATIBLE WITH FIRE RATING 2 SVR EXIT QED316-36"-7FT-689 1 EXIT TRIM QRT330—E—SC-KD-689 2 BURNS PULL PLATES #5410-32D-26D—GRIP 45 MIN. FIRE RATED HOLLOW METAL DOOR PAINTED SW6991 "BLACK MAGIC" (2) BURNS PUSH PLATES #54—US32D, (4) IVES KICK PLATES #8400—S32D-8X34 (2) STANLEY DOOR CLOSERS QDC311-689 (SEMI —GLOSS) — BOTH DOOR & DOOR FRAME. 103B G 6' — 0" 7' — 0" 1 3/4" 3 PAIR HINGES 1 VON DUPRIN GUARD—X EXIT ALARM LOCK #2670-28 1 VON DUPRIN GUARD—X DOUBLE DOOR STRIKE #2609 1 DETEX DOUBLE DOOR HOLDER #DDH-2250 TOP & HOLLOW CORE INSULATED METAL DOOR. SEE SHEET A2 FOR EXTERIOR BOTTOM, (4) STANLEY DOOR CLOSERS QDC311-689, (2) BURNS PULL PLATES #5410-32D-26D-GRIP, (1) 2" DOOR SCOPE #DS/1000MB, PAINT. PAINT INTERIOR SW6991, "BLACK MAGIC" (SEMI —GLOSS) — BOTH DOOR (2) 8" DOOR HOLDERS #608Z, (1) NATIONAL GUARD HD THRESHOLD #425 HD-6 FT., (2) DOOR SWEEPS, WEATHERSTRIPPING. (1)7015SC8-26D RIM CYLINDER & DOOR FRAME. 104 A 3' — 0" 7' — 0" 1 3/4" (1-1/2) PAIR HINGES, (1) STANLEY STOREROOM LOCKSET QCL270-E-626—S4—SC-KD — KEY #2, SOLID CORE WOOD DOOR OR HOLLOW CORE METAL DOOR PAINTED SW6991, (1) STANLEY DOOR CLOSER QDC311-689, (1) IVES WALL STOP #402-1/2B-26D. "BLACK MAGIC" (SEMI -GLOSS). UNDERCUT WOOD DOOR OR PROVIDE GRILL IN HM DOOR FOR VENTILATION. 105 A 3' — 0" 7' — 0" 1 3/4" (1-1/2) PAIR HINGES, (1) STANLEY STOREROOM LOCKSET QCL270—E-626—S4—SC—KD — KEY #2, SOLID CORE WOOD DOOR OR HOLLOW CORE METAL DOOR PAINTED SW6991, (1) STANLEY DOOR CLOSER QDC311-689, (1) IVES WALL STOP #402-1/2B-26D. "BLACK MAGIC" (SEMI -GLOSS). UNDERCUT WOOD DOOR OR PROVIDE GRILL IN HM DOOR FOR VENTILATION. 106 H 6' — 0" 7' — 0" BY DOOR MANUFACTURER TO BE RE —KEYED BY DOLLAR GENERAL AREA MANAGER WITH (1) ILCO RIM CYLINDER #7015SC8-26D. 21'-0" BI—PART WITH TRANSOM AND GLASS. BRONZE FINISH. REFER TO COVER SHEET FOR VENDOR INFORMATION. C f NOTE: PULL HANDLES AND DOOR CLOSERS ARE TO BE LOCATED ON THE NON -SALES SIDE OF DOORS. D i (��\_ LEVER HANDLE 3'-070, INTERIOR DOORS TYP. o TACZO DOOR VIEWER f` LEVER HANDLE W/KEY #1 3'-0" op CD OFFICE DOOR NOTE: PULL HANDLES AND DOOR CLOSERS ARE TO BE LOCATED ON THE PULL RECEIVING HANDLES SIDE OF DOORS. 8" KICK PLATES FRONT & BACK K///Z /I 3' — 0" 3'-0" CiD INTERIOR RECEIVING DOORS I EMERGENCY EXIT ONLY A-M WILL SOUND ALARM PANIC DEVICE O EMERGENCY EXIT DOOR I FULL HEIGHT - ASTRAGAL (EXT.) 0 % 2" VIEWER i 8" KICK DOWN DOOR HOLD OPENERS 01 3' — 010 L I - V of ADDRESS # I o. O I 0 0 o HSS 4X4 REFER TO STRUCTURAL DRAWINGS 0 I i� HSS 4X4 REFER TO STRUCTURAL DRAWINGS 3'-2" 4' 4'-0" 6'-0„ 4'-0" 4" 3'-2" 7,-6„ 7,_601 „ 40 14'-0" CE) STOREFRONT ENTRANCE EXTERIOR REC 1 DOOR DETAILS Scale: NTS CONSULTANT: SEAL: JOHN BENEDICT POLSINELLI, AR96059 THIS DRAWING SHALL NOT BE USED FOR CONSTRUCTION PURPOSES UNTIL THE SEAL AND SIGNATURE OF THE RESPONSIBLE REGISTRANT APPEARS ON THE DRAWING, AND PROPER PERMIT FORMS AND RELATED FEES ARE TRANSMITTED BY THE OWNER, OWNER'S AGENT OR CONTRACTOR TO THE AUTHORITY HAVING JURISDICTION. DATE ISSUED FOR REV 09/27/201 8 PEMB COORDINATION 11/27/2018 OWNER REVIEW 12/18/2018 PERMIT SUBMITTAL Project Manager Drawn L. LONG B. JACKSON Project Leader Checked L. LONG G. KARANFILOVSKI Date Dept Mgr Approval 08/07/2018 G. KARANFILOVSKI Client PALMETTO ZEPHYRHILLS-20th St, LLC P.O. BOX 1 61 5 THOMASVILLE, GA 31 792 Office: (229) 226-0682 Contact: John Tate Project DOLLAR GENERAL 38965 CR 54 Zephyrhills, FL 33542 (City of Zephyrhills) Store #: 20360 Drawing Title DOOR SCHEDULE AND DETAILS DO NOT SCALE DRAWING Project No. Drawing No. JCDTA 8.0233 A5 6'-11 %2" i �GENDER� / NEUTRAL IVES WALL / 0411 MOUNTED I 7'-4Y2" I DOORSTOP _ —�---- 4" TYP 104 � Q McCUE TRIM KIT 6'-6" W WITH BUMPER U GUARDS AND 10 CART STOP d. (REF DETAIL 5 A6 HALL THIS SHEET) — 107 105 I _ I I IVES WALL MOUNTED / DOOR STOP —� 7'-4/2" - _\ -1 A GENDER °° `gyp" NEUTR L r 3 A4 m \ 10 5 C LO � I 102 SALES AREA 7'-4%2" 100 ROOM M BREAK r 100 M IVES WALL MOUNTED 17 DOORSTOP 101 4'-0%2" 3'-0 4' O 101 OFFICE McCUE TRIM KIT WITH BUMPER GUARDS AND 4/„ CART STOP 7'-8%2" (REF DETAIL 5 0 THIS SHEET) LOW WALL PARTITION O O co co 'T° ' D J L on C° o Q I 12"X12" LOUVERED VENT ``' r FOR HUB DRAIN ACCESS - MAINTAIN REQUIRED n — INTERNATIONAL HEIGHTS AND _ _ VENDER SYMBOL OF CLEARANCES FOR ACCESSIBILITY DRINKING FOUNTAINS 2" NEUTR _ ACCESS PANEL DETAIL 1O � HC WALL SIGN _ Scale: 1/2"=1-0" EO SIGNAGE SHALL COMPLY WITH ANSI All 17.1 2009 SIGNS 40" SHALL HAVE A NON -GLARE FINISH. CHARACTERS AND O REAR WAL SYMBOLS SHALL CONTRAST WITH THEIR 1/2" GYPSUM BOARD ON FINISHED BACKGROUND. 2-1/2" METAL STUDS @ co M FLOOR 16" O.C. THIS WALL Q _....._ __ HC RESTROOM SIGN LOCATED ON THE WALL ADJACENT TO THE LATCH 1/2" GYPSUM BOARD X\ _._ I ' Y SIDE OF THE DOOR OR ON THE NEAREST ADJACENT WALL, Q Y I - - - p PREFERABLY ON THE RIGHT ON 3-5/8" METAL _ Q o z ivL i Q 'v _ STUDS @. 16" O.C. �, v v m 02 ADA, _ oo - _ SE r c�, 2, _ FINISHED O "� N o N r-- Z NOTE #2 N O O O FLOOR t ACCESSIBILITY SIGNAGE SOAP GRAB BAR EWC RAIL ELEV TOILET AND MIRROR UNIT BABY HAND DRYERCOAT HOOK Scaler 1" = 1'-0" o DISPENSER TOILET PAPER CHANGING N N ADA DRINKING FOUNTAIN (REF PLUMBING) WALL HYDRANT (REF PLUMBING) 1/2" GYPSUM BOARD ON 3-5/8" METAL STUDS @ 16" O.C. 1/2" GYPSUM BOARD ON 2-1/2" METAL STUDS @ zzC) 0 N CONTRACTOR SHALL LEAVE AN AS -BUILT SET OF CONSTRUCTION PLANS, ROLLED UP AND PLACED INSIDE 4"x36" PVC PIPE MOUNTED HORIZONTALLY ON THE WALL ABOVE THE DOOR 0? d- IVES WALL MOUNTED DOOR STOP 6 A3a HOLDER STATION NEW TACTILE EXIT SIGNAGE i rirrrr� T/'1 T� nn ni irrT r�r� r�rTn n � 9 MOUNTING HEIGHTS 8" HORIZONTAL BUMPER TRIMMED TO 8" SHORTER THAN THE SPACE WHERE APPLIED, CENTER IN SPACE. McCUE TRIM KIT ASK FOR THE KIT OPTION E\F - N II 8" PVC BUMPER GUARD (TOP AND BOTTOM) (1) 36" CORNER GUARD BUMPER GUARD DETAILS 5 Scale: NTS 4'-0" MIN CLEAR FLOOR SPACE FOR iV I LAVATORY FIXTURE 3 ADA CLEARANCES Scale; NTS 2'-0" MIRROR a W/ FRAME c 1'-6" MIN. Z c O L0 10" x 6" LOUVERED - 4" BASE A VENT, (1) IN EACH RESTROOM NORTH RESTROOM/OFFICE/BREAK ROOM PLAN Scale:1/4" = V-0" RESTROOM ELEVATIONS Scale: NTS � TACTILE EXIT SIG NAG E Scale. 1/2 - 1-0 4'-0" MIN I CLEAR FLOOR SPACE P N 0 H LO 0 0 3/8" M INTO 1/2" MAX CONTRACTOR TO VERIFY THAT EXISTING SIGNAGE COMPLIES WITH THIS DETAIL. IF SIGNAGE DOES NOT COMPLY OR DOES NOT EXIST THEN PROVIDE NEW PER DETAILS & AS REQUIRED BY LOCAL AUTHORITIES. FIN. FLR 1'-6" 1 7" - 19 TACTILE CHARACTERS TO BE FONT 'SANS SERIF' (ALLUPPERCASE) WITH MAX. HEIGHT OF 2", WIDTH TO HEIGHT RATIO BTWN 3:5 AND 1:1 AND STROKE WIDTH TO HEIGHT RATIO BTWN 1:5 AND 1:10. CHARACTERS SHALL BE RAISED 1/32" FROM SIGN SURFACE.. SIGNAGE BACKGROUND TO BE CONTRASTING COLOR TO TEXT. GRADE 2 BRAILLE EITHER CENTERED OR JUSTIFIED LEFT 3/8" TO 1/2" MAX BELOW TACTILE CHARACTERS. SEE ADA ACCESSIBILITY GUIDELINES FOR BRAILLE SPECIFICATIONS. TACTILE EXIT SIGNAGE DETAIL O c� Z N i� 8" 6" MIN MAX 0 c Scale: 6" = V-0" 34" A.F.F.- 4 GRAB. BAR. DETAIL Scale: NTS MIRROR ,SOAP DISPENSER PAPER TOWEL HOLDER INSULATE AROUND PIPES 8" MIN V61 2 17" MIN. BASS SECURITY SERVICES, INC. 888-774-3400 EXT. 2024 BASS SECURITY PARTS B155 BOBRICK 24 OZ. SOAP DISPENSER B2740 BOBRICK DOUBLE TOILET TISSUE DISPENSER B253 BOBRICK PAPER TOWEL DISPENSER 54-US32D BURNS PUSH PLATE 5410-32D-26D-GRIP BURNS PULL PLATE DDH-2250 ** DETEX DOUBLE DOOR HOLDER DS/1000MB DOOR SCOPE (FOR RECEIVING EXIT DOOR) 608Z 8" DOOR HOLDER 770SAV-3FT 3 FT DOOR SWEEP 770SAV-4FT 4 FT DOOR SWEEP W101S-DANE-626 FALCON PASSAGE LEVERSET W581 PD-DANE-626 FALCON STOREROOM LEVERSET A-2436 GAMCO 24" x 36" ANGLE FRAME MIRROR 150Sx36 GAMCO 1 1/2" X 36" GRAB BAR 150Sx42 GAMCO 1 1/2" X 42" GRAB BAR 150Sx18 GAMCO 1 1/2" X 18" GRAB BAR MS-1 GAMCO MOP HOLDER 5400 HAGER DOOR CLOSER 7015SC8-26D * ILCO RIM CYLINDER 402-1/213-26D IVES WALL STOP 452B26D-4 IVES 4" DOOR HOLDER 8400-S32D-8X34 IVES KICK PLATE NATIONAL GUARD HD THRESHOLD 425 HD - 6 FT. (FOR RECEIVING EXIT DOOR) TA331OPC TACO DOOR VIEWER 2670-28 VON DUPRIN GUARD-X EXIT ALARM LOCK 2609 ** VON DUPRIN GUARD-X DOUBLE DOOR STRIKE 892SAV-84INCH WEATHERSTRIPPING * MUST HAVE ONE RIM PER EXIT DEVICE. ** MUST HAVE DOUBLE DOOR STRIKE AND TWO DOUBLE DOOR HOLDERS FOR ALL DOUBLE EXIT DOORS. REST ROOMS: 1. RESTROOMS SHALL COMPLY WITH ALL BUILDING (FEDERAL, STATE, AND LOCAL) FIRE, AND HEALTH DEPARTMENT CODES AND ADA REQUIREMENT. 2. PROVIDE AND INSTALL 2'x3' MIRROR (OR LARGER IF REQUIRED BY CODE). 3. CONTRACTOR TO INSTALL SOAP DISPENSERS, TOILET PAPER HOLDERS, DOOR CLOSERS, DOOR HOLDERS, EXHAUST FANS, AND ALL BASS SECURITY PARTS IN BOTH RESTROOMS.FAUCETS SHALL BE OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE TIGHT GRASPING, PINCHING OR TWISTING OF THE WRIST. 4. INSTALL INSULATION ON ALL EXPOSED PIPES BELOW SINKS AND LAVATORIES TO COMPLY WITH STATE AND LOCAL CODES. 5. SEE FIXTURE MOUNTING HEIGHTS FOR ALL TOILET ROOM ACCESSORIES. VERIFY HEIGHT WITH LOCAL CODES. 6. CONTRACTOR TO VERIFY LOCATION OF OWNER SUPPLIED TOILET ACCESSORIES WITH ARCHITECT PRIOR TO INSTALLATION. 7. 6"x9" ACCESSIBLE TOILET ROOM SIGNAGE TO BE WHITE TEXT AND SYMBOLS ON BLUE BACKGROUND, TYP. VERIFY REQUIREMENTS WITH LOCAL CODES. 8. WHERE WASTE RECEPTACLES, DISPENSERS AND OTHER EQUIPMENT WITH CONTROLS ARE PROVIDED, AT LEAST ONE OF EACH IN EACH TOILET ROOMS SHALL BE LOCATED ON AN ACCESSIBLE ROUTE WITH ALL OPERABLE PARTS WITHIN 48" FROM THE FINISHED FLOOR. 18" VERTICAL GRAB BAR PER CODE STAINLESS STL. GRAB BAR 2 ROLL TOILET TISSUE HOLDER d- g co 54 MIN. 42 MIN. 39" - 41 12 r d- M m CONSULTANT: SEAL: JOHN BENEDICT POLSINELLI, AR96059 THIS DRAWING SHALL NOT BE USED FOR CONSTRUCTION PURPOSES UNTIL THE SEAL AND SIGNATURE OF THE RESPONSIBLE REGISTRANT APPEARS ON THE DRAWING, AND PROPER PERMIT FORMS AND RELATED FEES ARE TRANSMITTED BY THE OWNER, OWNER'S AGENT OR CONTRACTOR TO THE AUTHORITY HAVING JURISDICTION. DATE ISSUED FOR REV 09/27/201 8 PEMB COORDINATION 1 1 /27/201 8 OWNER REVIEW 12/1 8/201 8 PERMIT SUBMITTAL Project Manager Drawn L. LONG B. JACKSON Project Leader Checked L. LONG G. KARANFILOVSKI Date Dept Mgr Approval 08/07/2018 G. KARANFILOVSKI Client PALMETTO ZEPHYRHILLS-20th St, LLC P.O.. BOX 1615 THOMASVILLE, GA 31 792 Office: (229) 226-0682 Contact: John Tate Project DOLLAR GENERAL 38965 CR 54 Zephyrhills, FL 33542 (City of Zephyrhills) Store #: 20360 Drawing Title ENLARGED PLANS AND TOILET ROOMS DO NOT SCALE DRAWING Project No. Drawing No. .JCDT.18.0233 A6 ;r 26'-0" PROTOTYPICAL MAIN BUILDING SIGN FOR 'A', 'B', 'E' & 'F' SCHEMES 33'-3" THIS SIGN IS TO BE PROVIDED AND INSTALLED BY THE DEVELOPER OR CONTRACTOR AT THE BEGINNING OF CONSTRUCTION PROJECT. I 3 , s mw_ � e m M t .......... 3 PROTOTYPICAL MAIN MAIN BUILDING SIGN FOR'C' &'D' SCHEMES PRIMARYTKIS IS THE O. SIGN FOR ALL LOCATIONS. Building Signs Sign Size Sign Weight # of Circuits Asps Voltage 3'-0" x 28` box 441 1 b (1') 15 A 5 11 41-61 x 33_ " box 750 lbs. (1) 15 A 8.4 115 Building Letters Sign Size Sign Weight # of Circuits Amps Voltage 18" 215 lbs. (2) 15 A 19.6 115 24" 288 lbs. (1) 15 A & (1) 20 A 23.45 115 30" 87 1 bs . (2) 20 A 28 115 3 " 640 1b . (2) 15 A & (1) 20 A 32.9 115 Monument Signs Sign Size Sign Weight # of Circuits Amps Voltage 4' x 8' 188 lbs. (1) 15 A 1.7 115 5' x 10' 375 lbs. (1) 15 A 3.4 115 8' x 1 ' 738 lbs. (1) 15 A 5 115 SIGN SPECIFICATIONS 1. BUILDING SIGN: PROVIDE CONDUIT AND WIRE FROM ELECTRICAL PANEL TO THE SIGN. THE CONDUIT IS TO BE 1" AND HAVE ONE SET OF 10/2 WIRE WITH GROUND. THERE SHALL BE SUFFICIENT SUPPORT FOR THE DOLLAR GENERAL SIGN OF UP TO 1400 LBS. NOTE: IF THE LEASE SPECIFIES A 36" LETTER SET (1200 -1348 LBS CRATED), 1 qty. - 10/2 WIRE WITH GROUND. 2. MONUMENT SIGN: PROVIDE CONDUIT FROM ELECTRICAL PANEL TO LOCATION OF THE MONUMENT SIGN BASE. BURY CONDUIT UNDER PARKING AREA. REFER TO ELECTRICAL PLANS FOR CONDUIT AND WIRES. NOTE: USE 4'-0" X 8'-0" MONUMENT SIGN - REFER TO CIVIL DRAWINGS FOR LOCATION. 3. FINAL ELECTRICAL CONNECTIONS FOR SIGN SHALL BE THE SIGN VENDORS RESPONSIBILITY SINCE THE 'S BOX AND WIRES ARE IN PLACE. 4. SEE CHART ABOVE FOR SIGN SPECIFICATIONS. 5. SEE SHEET A8 FOR SIGN BRACING DETAILS. 6. MONUMENT SIGN CABINETS TO CLEAR 15' FROM GRADE AND EDGE SHALL BE LOCATE NO CLOSER THAN 10' TO ANY OVERHEAD UTILITY LINES. 16'-1 " 10'-1 " 1, 1, 8'-0 1 /2" L L 10'-0 1 /2" 0 LO JSE ONLY. � SIGN ®ETAILS Scale: NTS I ONLY.THIS SIGN IS FOR SPECIALTY USE N 9 F_ THIS SIGN IS FOR SPECIALTY USE ONLY. CONSULTANT: SEAL- JOHN BENEDICT POLSINELLI, AR96059 THIS DRAWING SHALL NOT BE USED FOR CONSTRUCTION PURPOSES UNTIL THE SEAL AND SIGNATURE OF THE RESPONSIBLE REGISTRANT APPEARS ON THE DRAWING, AND PROPER PERMIT FORMS AND RELATED FEES ARE TRANSMITTED BY THE OWNER, OWNER'S AGENT OR CONTRACTOR TO THE AUTHORITY HAVING JURISDICTION. DATE ISSUED FOR REV 09/27/201 8 PEMB COORDINATION 1 1 /27/201 8 OWNER REVIEW 12 18 2018 PERMIT SUBMITTAL Project Manager Drawn L. LONG B. JACKSON Project Leader Checked L. LONG G. KARANFILOVSKI Date Dept Mgr Approval 08/07/2018 G. KARANFILOVSKI Client PALMETTO ZEPHYRHILLS-20th St, LLC P.O. BOX 1 61 5 THOMASVILLE, GA 31 792 Office: (229) 226-0682 Contact: John Tate Project DOLLAR GENERAL 38965 CR 54 Zephyrhills, FL 33542 (City of Zephyrhills) Store #: 20360 Drawing Title SIGN DETAILS DO NOT SCALE DRAWING Project No. Drawing No. JCDT.18.0233 A7 F 0 NOTE: SIGNAGE SHALL BE B ®UNDER SEPARATE PERMIT AgiLight WHITE LED (4500° K) ELECTRICAL OUT PROVISION �_-_-'.wi ,rt • w 1_I / a_-1 iw_ +we, y"•!s I.a �♦ 0e B /s�wo`♦ l ® 9 i8♦ 1 .' 0 B tI_w♦a♦ I ♦ 1 1 ♦ ° i i ♦ ♦ 1 ® ® ! I P B 8 .1 � f f•1 I B 1•B 1.0 /A#j\0 1 1•i ,ws B °•° 1 1 f 1 1 i ! ♦ 1 1 B%B 1/ __ _% � 1,.+• A aro B 1 e_e_. 1 / ♦ 1 ♦ wa- A..__-® t , lo� ° !m _ / ,♦ 1 1 , 1* / ° °• ®1 ° / 0 *� / ° / /1/ ,/ / / w.rwr.. / 1-�-® ; i_-...@® 1 i _ / 1 ♦ ° 1• `®ml �,IVBi I 1 1--- 1 / �� i' I__♦ Ivt ♦' 1 1 f ® ♦ 1 , i• J//1t`\\ ♦ 1• I i[�♦ ♦% 1° 2'-10 33116" 3'-1 1116" Z'-4 31/1E6 --2'-7 35/16" 2'-913/16" 4'111/16" 3'-1" Ti 1/16" 2'-1 1/2" 2'-413116"---3'-35/16' 2'-95116" 50 LEDs 44 LEDs 27 LEDs 27 LEDs 44 LEDs 48 LEDs 44 LEDs 41 LEDs 46 LEDs 41 LEDs 48 LEDs 44 LEDs 27 LEDs LED LAYOUT CONDUITTO CONDUIT BUILDING WALL General LED PRIMARY DRIVER ZO AMP WIRING DIAGRAM LETTER RACEWAY DISCONNECT SWITCH ELECTRICAL REQUIREMENTS: LED: (531) AgiLight LS-CORE-45K-01 WHITE (4500° K) 120 LEDs MAX DRIVER: (6) General LED PS12-60W-100-277V @ 0.8 AMPS PER DRIVER TOTAL LOAD: 4.8A @ 120VAC CIRCUITS: (1) 20 AMP REQUIRED CLIENT: ,; �Do�AR �� /t f® AL 4- 36" LETTERS W/ ALUM, BACKER - 140 MPH SI{L aY:" Project Number. LINK Engineering L.L.C. n35 souu,o maL N xvU°,'rvmwsrc3T922 �-'% I'ItO $es153a AoohFax (865, sag-96>1. " —f� oea ne twm-.ankangr.cmn ® _...... - NOTE: ldl we is and plans Indicated an this drawing era the We ' rty of Da dir General tor4 tigt, created specificalty for the noted project Um of these desgns o pw s {oranypurposeochethanOF prahDited vidlxout the written consent of Odlor Generd Cprpomtion. Disdasure pf Ue information enclosed wi{hw, without consent of owner, is p vioiottan of any." inteitecturil ert and &.11 not bs tolerated. 63N1ft3 - ADDED SQ FT SG -- 3 DATE: / / C31 04! 1 J� Draii Number: B314QD3 ZE 09104172 MISC; REVISION PER FEEDBACK JBL - REV. DATE DESCRIPTION BY: APR: 6" EXTERIOR FINISH RACEWAY ELECTRICAL OUT SIGNCOMP 8" RACEWAY SYSTEM; PROVISION; AS SHOWN PAINT TO MATCH BUILDING —4'-0" 4'-0" T - 4'_0,, 3'-6" 21_10* 2'-3'— 4 1116" r l 16'-3 9/16" 1 I #10 MACHINE SCREW 0,125" ALUM. PANEL; W/ RIVET -NUT, FLAT, MATTE BLACK 2 PART ELEVATION & MOUNTING LOCATION & LOCK WASHERS POLYURETHANE PAINT 3/8" DIA. HILTI HLC SLEEVE ANCHOR W/ A MINIMUM 3/8" DIA. THREADED OF 1 1/4" EMBEDMENT ROD W/ NUT, FLAT, & LOCK WASHERS 4"1 ALUM. PLATE ----------------------- 1 1/2"1 1/2"x3/16" STEEL ANGLE; (6061-T6) ------ ------ ------ MUST SPAN A MIN. OF (2) STUDS & ATTACH TO EACH STUD W/ 1/4" FASTENERS I I I MOUNTING @ FRAMED WALL I„ �MI Illy WALL STUD @ 16" O.C. 1 CONDUITTO PRIMARY I WALL I SHEATHING 112" DIA. PIPE SPACER 1 4"x13"x3/8" ALUM. PLA (6061-T6) 7/16" DIA. HOLE MOUNTING PLATE DETAIL 'I FTTi Vii Al I IRA RA(i _ LETTER ELECTRICAL OUT PROVISION; AS SHOWN IT-9 LETTER MOUNTING LOCATION; AS SHOWN MOUNTING d MASONRY WALL MI'H '. 2 JBL properly of halt a{ these xi Jisdosurr e at OF DATE: a vroktion of 3 03/0$/13 0" 11 1/2" 4' 13"x3(8" ALUM. PLATE (6061-T6); PAINT TO MATCH BUILDING HILTI ANCHOR SYSTEM TO BE INSTALLED IN STRICT ACCORDANCE WITH MANUFACTURERS SPECIFICATIONS AND RECOMMENDATIONS, MASONRY WALL CONDU IT TO PRIMARY RACEWAY PROFILE 13-0181 LINK Engineering, L.L.C. Ong. Number.. L Imo.._^ +as sn"ti:Darin �arwrKnaxvma. rv+v,essse s�sn L / h:� Phorre: iC651-539-4nGl.rax: (.M i349651 6314003 ' l of a e: w w.I19r. om 1T-7 3/8" Q V m 0.125" ALUM. ELEVATION --BOND TO PANELS 0.125" ALUM. PANEL; LETTERS; #2037 YELLOW SEAM @ 0,125" _ _ MATTE BLACK 2 PART ACRYLIC FACES ALUM. PANEL T_ _ _ - POLYURETHANE PAINT 0.125" ALUM. SIGNCOMP #1986 8" RACEWAY -5"--j--713/16" PANEL COVER; PAINT TO MATCH BUILDING -- _----_--_-- _ ALL EXPOSED FASTENER HEADS DETAIL fa? SEAM 0.125" ALUM. 0.050' ALUM. RETURN; SHALL BE PAINTED TO MATCH PANEL MILL PAINT MATTE BLACK SIGNCOMP #1979 8" RACEWAY THE EXTERIOR CABINET FINISH 0.090" ALUM, BRACE/BRACKET @ EACH - SQ. FT. BACK MOUNTING PLATE & DRIVER ACTUAL- 131,16 s%ft. SIGNCOMP #1982 8" RACEWAY BOXED - 149.45 sq. ft. #10 S.S. HEX BACK; PAINT TO MATCH BUILDING NOTES: HEAD THREAD 1. Design is based on 140 mph 3 second gust ROLLING SCREW 1" BLACK #8 S.S. THREAD ROLLING 0.125" ALUM, design wind speed per IBC 2006. Category II. 3116" ACRYLIC FACE; SCREW 15" O.C. PANEL E Exposure C, components & cladding, zone 5. #2037 YELLOW � JEWELITE _ — - _ � _ _ _ _ P p 9= 5" STAPLE/CLINCH OR 2. No additional wind catching surfaces are tr _ RIVET PERIMETER added to the building structure. The 0.050" ALUM. customer's building engineer is to determine 0.090" ALUM. 0.090" ALUM. 3/16" RETURN _rBACK the adequacy of the supporting stricture, BACK ACRYLIC 3, Aluminum housings shall be fabricated from FACE _ _ 3003-H14 sheet. Extruded shapes shall be T #10 MACHINE SCREW 6063-T6, unless noted otherwise. DETAIL (a7 RETURN 4, All fasteners shall be zinc coated to I W1 RIVET -NUT, FLAT, prevent corrosion unless noted otherwise. r CONDUIT TO & LOCK WASHERS 5. All wall penetrations shall be sealed PRIMARY (BEYOND) to prevent water intrusion. INTERIOR OF LETTERS TO BE . 6. This design is prototypical and should not 1 8 EACH SIDE OF PAINTED LACRYL STARBRITE WHITE, be used for site specific applications unless 118" PLATES; TYP. RAW EDGES OR UNCOATED reviewed and deemed suitable for use at that 114" DIA. BOLT W/ SURFACES SHALL NOT BE USED. site by a competent Professional Engineer. RIVET -NUT: FLAT & i I 4"x13"x3/8" 1`.LUM. PLATE AgiLight WHITE LOCK WASHERS I (6061-T6); PAINT TO LED (4500° K) MATCH BUILDING GRAPHICS DEPICTED ON THIS DRAWING ARE FOR ILLUSTRATIVE PURPOSES ONLY, DO NOT USE THIS DRAWING FOR PRODUCTION ART, General LED TOP & BOTTOM OF REFER TO PRODUCTION ELECTRONIC FILES 1 1 /4" DIA.__",!�� DRIVER RACEWAY; TYP. WEEP HOLES (2) 1/4" DIA. TYPICAL SECTION WEEP HOLES I SIGNCOMP #1981 8" RACEWAY - - FRONT; PAINT TO MATCH BUILDING FABRICATED RACEWAY IS ACCEPTABLE _ WITH SHOP SUBMITTALS. DETAIL @RACEWAY CLIENT: 36" LETTERS W/ ALUM. BACKER - 140 MPH SHT. BY: Project' Number. NEngineering 7y ys 7+`y� �... NOTE: AN dostgrre and plain indicated anthisdrawing as the sate property of 1 JBL 1 3-0.181 LINK El[g[need in L.L.C. j 03fD1113 ADDED SQ FT - gC Dollar Genarai Caraarattrm, crewed spsctflcaily for the noted prajest U� of these _ _ - GENERADOLLAR „ — designs or plans far any PPurpose other than the Intended oppiicotzm shol( be OF - DATE: Drpwin Number: MISC. REVISION Pert FEEDHAGY. d — prahbiled without the wR w aaneent of Dollar General Corp anion. D1.1a611re of Z h r� .I 9 /Y�- t355°u[h rJavitl L K oxNll T 6see 31922 any of tfie infwmafim, me gsed withal, without aonsent of pwner, is a Wai of 3 03/04/ 1 3 8314003 Phon3: (86 REV: DATE DESCRIPTION ny. APR: in{ei f " r a dsZo nai tes tolerated. oarine..t•«w.Im6eaa,cma CONSULTANT: SEAL: JOHN BENEDICT POLSINELLI, AR96059 THIS DRAWING SHALL NOT BE USED FOR CONSTRUCTION PURPOSES UNTIL THE SEAL AND SIGNATURE OF THE RESPONSIBLE REGISTRANT APPEARS ON THE DRAWING, AND PROPER PERMIT FORMS AND RELATED FEES ARE TRANSMITTED BY THE OWNER, OWNER'S AGENT OR CONTRACTOR TO THE AUTHORITY HAVING JURISDICTION, DATE ISSUED FOR REV 09/27/201 8 PEMB COORDINATION 11/27/201 8 OWNER REVIEW 12/18/2018 PERMIT SUBMITTAL Project Manager Drawn L. LONG B. JACKSON Project Leader Checked L. LONG G. KARANnLOVSKI Date Dept Mgr Approval 08/07/2018 G. KARANFILOVSKI Client PALMETTO ZEPHYRHILLS-20th St, LLC P.O. BOX 1615 THOMASVILLE, GA 31 792 Office: (229) 226-0682 Contact: John Tate Project DOLLAR GENERAL 38965 CR 54 Zephyrhills, FL 33542 (City of Zephyrhills) Store #: 20360 Drawing Title SIGN BRACING DETAILS DO NOT SCALE DRAWING Project No. Drawing No. JCDT.18.0233 A8 1" CONDUIT TO EMS PANEL BELOW CABLE TRAY 12'-10 1 /2" ± CUT SECTION AS REQ'D RECEIVING AREA 103 N Z ti o � z NOD %gib �wW U) J ? Q my Q U CABLE TRAY: 38'-4" 2'-6" CUT SECTIONS AS REQ'D CABLE TRAY CNR. SALES AREA 102 CABLE IIRAY: 52'-11" CUT SECTIONS AS N R. in i Q Q U) z �O - U 4'-4" Q W CT u BUNDLE ALL U WIRES AND ROUTE U TO CABLE TRAY 2'-6" TEE. TYP. CA 3LE TRAY C JT TO FIT **PRE -PUNCHED 1 1/4" �O GALVANIZED ANGLES ARE APPROVED EQUAL TO UNI-STRUT UNISTRUT FOR GRAPHICS BY OTHERS. BOTTOM OF SIGNAGE T-0" AFF. U '-11" ± C.T@ 3 5/8" 20 GA. METAL STUD TO 1/2" MIN GYP STRUCTURE ABOVE BD TO DECK ABOVE BOX HEADER: LE- 2 X 4 A.C.T. CLG jk (2) 6" 20 GA. METAL @ 8'-0" A.F.F. STUDS W/ 3 5/8" TRACK TOP AND 5/8" GYPSUM BOARD BOTTOM. TO 6" ABOVE FINISHED CEILING B.O. BULKHEADrh @ T-0" A.F.F. WJ NOTE: IF A GYPSUM BOARD CEILING IS INSTALLED IN THE HALLWAY AN ACCESS PANEL MUST BE INSTALLED FOR ACCESS TO THE WATER HEATER. (MINIMUM 20"x30") SECTION AT SOFFIT Scale: 1" = V-0" TOP OF PEMB PURLIN (TYP) A 3/32" 7x7 AIRCRAFT CABLE. INSTALL HANGER CABLES USING ALL \ ATTACHMENTS DEVICES AS SPECIFIED BY WIRE MANUFACTURER. CABLE TRAY NOTE: TOP OF LIGHT FIXTURE GC SHALL PROVIDE MOUNTED @ 11'-0" A.F.F., pcbAND INSTALL �\��� CABLE TRAY L NEIRE 6 5 4 3 2 1 P' MOUNT WITH AIRCRAFT CABLE TO UNISTRUT, UNISTRUT ATTACHED TO UNDERSIDE OF PURLIN. 2 CABLE TRAY PLAN 3 LIGHT ATTACHMENT DETAIL Scale: NTS Scale. 1 1/2 - 1-0 9 NORTH REFLECTED CEILING PLAN Scale: 1/8" = V-0" RUNNERS ga VERTICAL RS THREE 1111"m AN SUSPENDED GRID DETAIL Scale: 1" = V-0" 8'-0" A.F.F. GENDER NEUTRAL GENDER NEUTRAL OPEN TO ABOVE BREAKROOM CENTER LIGHT IN 100 ROOM OPEN TO ABOVE CENTER LIGHT II ROOM METAL PANEL CEILING (BY P 0 10'-0" A. F. F. LEGEND PANEL/CIRCUIT NO. AM 2 LIGHT FIXTURE TYPE A NIGHT LIGHT CIRCUIT A NL LIGHT FIXTURE TYPE B LIGHT FIXTURE TYPE C LIGHT FIXTURE TYPE D SUSPENDED CEILING GRID & ACOUSTICAL CEILING TILE EMERGENCY LIGHT W/ BATTER BACKUP K LIGHT EXIT SIGN W/ BATTERY BACKUP EXIT N WALL PACK J BI-DIRECTIONAL SECURITY LIGHTING M SUPPLY DIFFUSER RETURN DIFFUSER CONSULTANT: SEAL: JOHN BENEDICT POLSINELLI, AR96059 THIS DRAWING SHALL NOT BE USED FOR CONSTRUCTION PURPOSES UNTIL THE SEAL AND SIGNATURE OF THE RESPONSIBLE REGISTRANT APPEARS ON THE DRAWING, AND PROPER PERMIT FORMS AND RELATED FEES ARE TRANSMITTED BY THE OWNER, OWNER'S AGENT OR CONTRACTOR TO THE AUTHORITY HAVING JURISDICTION. DATE ISSUED FOR REV 09/27/201 8 PEMB COORDINATION 11/27/2018 OWNER REVIEW 12/18/2018 PERMIT SUBMITTAL Project Manager Drawn L. LONG B. JACKSON Project Leader Checked L. LONG G. KARANT(LOVSKI Date Dept Mgr Approval 08/07/2018 G. KARANFILOVSKI Client - PALMETTO ZEPHYRHILLS-20th St, LLC P.O. BOX 1615 THOMASVILLE, GA 31 792 Office: (229) 226-0682 Contact: John Tate Project DOLLAR GENERAL 38965 CR 54 Zephyrhills, FL 33542 (City of Zephyrhills) Store #: 20360 Drawing Title REFLECTED CEILING PLAN DO NOT SCALE DRAWING Project No. Drawing No. JCDT.18.0233 A9 - FIRE CAULK, TYP (BOTH SIDES) PARALLEL PURLIN/GIRT. CONDITION CONTINUOUS DEFLECTION RUNNER PEMB ROOF PANELS 00 PERPENDICULAR PURLIN/GIRT. CONDITION z Q _ J M FOR FIRE RATING: COMPLETELY FILL VOIDS AT TOP OF WALLS, AROUND ALL PENETRATIONS PER U.L. #WL-1017 MIN. 5/8" THICKNESS OF FILL MATERIAL INSTALLED ON EACH SIDE OF WALL BETWEEN TOP OF WALLBOARD AND ALL SURFACES OF THE STEEL DECK, FLUSH WITH EACH SURFACE OF WALLBOARD 1-HOUR FIRE -RATING: UL#U419, 465, HD-D-0489 or WP-1081 1 HR. = 1 LAYER GYP BD EACH SIDE - FIRE RATED GYP BD TO BE: U.S. GYPSUM CO. - TYPE SCX, SHX, WRX, IP-X1, AR, C, WRC OR IP-X2. - FIRE TAPE GYP BD IN LIEU OF STANDARD TAPING & SANDING. FINISHED FLOOR � FIRE RATED PARTITION PEMB INSULATION, COMPRESSION TO A DENSITY OF 4pcf, 50% IN THICKNESS FIRE CAULK, TYP (BOTH SIDES) CRIPPLE STUD ATTACHED TO DEFLECTION TRACK GALVANIZED DEFLECTION TRACK WITH OFFSET LEGS TO ACCOMMODATE GYP. BOARD ON METAL RUNNER, FASTEN TO TRACK @ 24" O.C. CONTINUOUS DEFLECTION RUNNER 5/8" MINIMUM TYPE'X' GYPSUM BOARD TO DECK ABOVE (BOTH SIDES) ON 3-5/8", 20GA, METAL STUDS @ 16" O.C. FLOOR w/0.177" 0 x1-7/16" P.A.F., SHOT THRU A 1"0 x 16GA. HOLELESS WASHER 8" CMU WALL. REF. STRUCTURAL DRAWINGS FOR GROUTING AND REINF. VERTICAL REINF (BEYOND) REF STRUCTURAL "BLOK-FLASH" BASE FLASHING SYSTEM - 1/2" EXPJOINT FILLER W/ SEALANT CONC SIDEWALK SLOPE AWAY FROM BLDG RE: CIVIL ' ELEV 0'-0„ feFINISH FI nnP - FACE OF STEEL COLUMN (BEYOND) 1/2" GYPSUM BOARD ON INTERIOR METAL WALL LINER PANEL — 3 5/8" METAL STUDS @ 16" O.C. EXTERIOR WALL AT C M U COI 4 3/8" 1 1 /2" = V-0" 1 1/2" 7 z M �j EXTERIOR WALL AT CMU 1/2" GYPSUM BOARD 2 1/2" METAL STUDS @ 16" O.C. VINYL FACE INSULATION AS SCHEDULED — EIFS ON EXTERIOR GRADE GYPSUM — METAL WALL PANEL — EIFS BULLNOSE SILL T/O EIFS BULLNOSE ELEV 4' 4" ._ 1 1 /2" = V-0" SEALANT CORE -FILL 500 IN ALL NON-STRUCTURAL MASONRY CELLS, TYP @ PERIMETER 8" CMU WALL. REF. STRUCTURAL DRAWINGS FOR GROUTING AND REINF. VERTICAL REINF (BEYOND) REF STRUCTURAL "BLOK-FLASH" BASE FLASHING SYSTEM CONC SIDEWALK SLOPE AWAY FROM BLDG RE: CIVIL ELEV 0' 0' FINISH FLOQR7 1 /2" EXP JOINT FILLER W/ SEALANT ALUMINUM CAP - PAINT TO MATCH WALL WOOD NAILER AS REQUIRED METAL TRACK 1/2" MIN GYPSUM BOARD (BOTH SIDES) ON 3 5/8"x20ga CORROSIVE -RESISTIVE METAL STUDS @ 16"oc SEALANT BOTH SIDES METAL TRACK FINISH FLOOR ELEV 0'-0" FINISH FLOOR GYP. BOARD ON MTL.. STUDS, 10'-0" HEIGHT 1 1 /2" = 1 '-0" COI EIFS ON EXTERIOR GRADE GYPSUM METAL WALL PANEL EIFS BULLNOSE SILL - SEALANT CORE -FILL 500 IN ALL NON-STRUCTURAL MASONRY CELLS, TYP @ PERIMETER PRE -FINISHED METAL\ DOWNSPOUT 8" CMU WALL. REF. STRUCTURAL DRAWINGS FOR GROUTING AND REINF. VERTICAL REINF (BEYOND) REFSTRUCTURAL "BLOK-FLASH" BASE FLASHING SYSTEM 1/2" PRE -MOLDED JOINT FILLER - CONC SIDEWALK SLOPE AWAY FROM BLDG RE: CIVIL ELEV 0'-0" FINISH FLOOR - z M_ VINYL FACE INSULATION AS SCHEDULED BY PEMB STEEL CHANNEL BY PEMB. REF. STRUCTURAL DRAWINGS FOR ATTACHMENT TO WALL. 1/2" GYPSUM BOARD ON INTERIOR METAL WALL LINER PANEL - <I � EXTERIOR WALL AT CMU z J a (D zI- J = w (a U llJ oz uJ I- U z W J J E! U- 00 U- rX uJ LL w PEMB ROOF PANELS — PEMB PURLIN/GIRTS. METAL STUDS, ATTACHED TO PEMB PURLINS/GIRTS. CONTINUOUS DEFLECTION RUNNER ACOUSTICAL TILE CEILING AND GRID (WHERE OCCURS, REFER TO REFLECTED CEILING PLAN) R-13 INSULATION TOILET ROOM WA FINISHED FLOOR TYP. PURLIN/GIRT. SPACING (5'-0" O.C.) 09 PEMB INSULATION, COMPRESSED AS REQ'D. FOR BLOCKING GALVANIZED DEFLECTION TRACK WITH OFFSET LEGS TO ACCOMMODATE GYP. BOARD ON METAL RUNNER, FASTEN TO TRACK @ 24" O.C. 1/2" MIN. GYPSUM BOARD ON 3-5/8", 20GA. METAL STUDS @ 16" O.C. TO UNDERSIDE OF DECK. GYPSUM BOARD TO RUN TO UNDERSIDE OF DECK ABOVE AT ALL "OPEN TO DECK ABOVE" AREAS OR TO 6" ABOVE CEILINGS. (USE MOISTURE RESISTANT GYPSUM BOARD AT WET LOCATIONS). FLOOR w/0.177" O x1-7/16"' P.A.F., SHOT THRU A 1"0 x 16GA. HOLELESS WASHER FULL HEIGHT PARTITION 1 1/2" = V-0" CONSULTANT: SEAL: JOHN BENEDICT POLSINELLI, AR96059 THIS DRAWING SHALL NOT BE USED FOR CONSTRUCTION PURPOSES UNTIL THE SEAL AND SIGNATURE OF THE RESPONSIBLE REGISTRANT APPEARS ON THE DRAWING, AND PROPER PERMIT FORMS AND RELATED FEES ARE TRANSMITTED BY THE OWNER, OWNER'S AGENT OR CONTRACTOR TO THE AUTHORITY HAVING JURISDICTION. DATE ISSUED FOR REV 09/27/201 8 PEMB COORDINATION 11/27/2018 OWNER REVIEW 12/18/2018 PERMIT SUBMITTAL Project Manager Drawn L. LONG B. JACKSON Project Leader Checked L. LONG G. KARANFILOVSKI Date Dept Mgr Approval 08/07/2018 G. KARANFILOVSKI Client PALMETTO ZEPHYRHILLS-20th St, LLC P.O. BOX 1615 THOMASVILLE, GA 31 792 Office: (229) 226-0682 Contact: John Tate Project DOLLAR GENERAL ® 38965 CR 54 Zephyrhills, FL 33542 (City of Zephyrhills) Store #: 20360 Drawing Title WALL TYPES DO NOT SCALE DRAWING Project No. Drawing No. JCDT.18.0233 A10 m GENERAL NOTES CONSTRUCTION SITE NOTES: 1 . THE GENERAL CONTRACTOR IS RESPONSIBLE FOR SITE SAFETY AND CONSTRUCTION MEANS AND METHODS IN THE PERFORMANCE OF THE WORK. PROVIDE ALL MEASURES REQUIRED TO PROTECT THE STRUCTURE, WORKERS AND OTHER PERSONS DURING CONSTRUCTION OPERATIONS. 2. CONTRACTOR TO COMPLY WITH ALL OSHA REGULATIONS, AND ANY OTHER SITE SAFETY REQUIREMENTS OF THE OWNER IN THE PERFORMANCE OF THE WORK. ALL WORK SHALL BE PERFORMED IN A SAFE MANNER AND ALL CONTRACTOR EMPLOYEES SHALL AT ALL TIMES WORK IN COMPLIANCE WITH THE OWNER'S SAFETY REGULATIONS AND ANY GENERAL CONTRACTOR SAFETY REQUIREMENTS. 3. PROVIDE ADEQUATE BRACING AND SHORING FOR CONSTRUCTION EQUIPMENT AND FOR THE BUILDING. PROVIDE SCAFFOLDING, SHEETING, TEMPORARY BARRIERS, BRACING OF EXCAVATIONS AND OTHER TEMPORARY SUPPORTS AS REQUIRED. DO NOT STORE OR STACK CONSTRUCTION MATERIALS ON ERECTED FLOORS OR ROOFS IN EXCESS OF 80 PERCENT OF THE SPECIFIED DESIGN LIVE LOAD. MINIMIZE DYNAMIC IMPACT TO EXISITNG STRUCTURES WHEN PLACING MATERIALS ON FLOORS OR ROOFS. 4. DO NOT OBSTRUCT EXISTING BUILDING DOORS OR EGRESS PATHS DURING THE PERFORMANCE OF THE WORK. 5. CONTRACTOR SHALL CLEAN THE SITE OF CONSTRUCTION DEBRIS TO MAINTAIN A SAFE ENVIRONMENT ON A DAILY BASIS. LEGALLY DISPOSE OF ALL HAZARDOUS AND NON -HAZARDOUS MATERIALS. GENERAL COORDINATION NOTES: 6. CONFORM TO ALL OWNER'S GENERAL AND SPECIAL CONDITIONS IN THE PERFORMANCE OF THE WORK OR AS HEREIN SPECIFIED. 7. ALL WORK IS TO BE PERFORMED IN ACCORDANCE WITH THE APPLICABLE BUILDING CODE AND ALL APPLICABLE STATE AND LOCAL CODES, ACCESSIBILITY STANDARDS AS WELL AS ANY APPLICABLE OWNER'S CORPORATE STANDARDS. THE LOCAL CODE AUTHORITY HAS THE AUTHORITY TO INTERPRET CODE REQUIREMENTS AND THESE INTERPRETATIONS MAY VARY FROM NORMAL INTERPRETATION AND INFORMATION REPRESENTED IN THE CONTRACT DOCUMENTS. THE CONTRACTOR SHALL INFORM THE OWNER'S REPRESENTATIVE OR THE ARCHITECT/ ENGINEER OF ANY DISCREPANCIES OR DIFFERENCES AND SHALL PROCEED WITH THE WORK ONLY UPON RECEIVING WRITTEN AUTHORIZATION 8. THE DRAWINGS SHALL NOT BE USED FOR CONSTRUCTION PURPOSES UNTIL THE SEAL AND SIGNATURE OF THE RESPONSIBLE REGISTRANT APPEARS ON THE DRAWING, AND PROPER PERMIT FORMS AND RELATED FEES ARE TRANSMITTED BY THE OWNER, OWNER'S AGENT, OR CONTRACTOR TO THE AUTHORITY HAVING JURISDICTION. 9. CONTRACTOR TO OBTAIN ALL REQUIRED CONSTRUCTION PERMIT FORMS, PAY ALL RELATED FEES, AND ARRANGE FOR ALL REQUIRED INSPECTIONS AND APPROVALS. 10. BIDDER/CONTRACTOR SHALL VISIT THE SITE, EXAMINE AND VERIFY EXISTING CONDITIONS UNDER WHICH THE WORK SHALL BE CONDUCTED AND ACCOUNT FOR EXISTING FIELD CONDITIONS AND ACTUAL FIELD DIMENSIONS IN ALL BIDS SUBMITTED AND ALL WORK PERFORMED. REPORT ANY DISCREPANCIES IN THE EXISTING CONDITIONS IMMEDIATELY TO THE OWNER'S REPRESENTATIVE OR ARCHITECT/ ENGINEER 1 1 . CONTRACTOR SHALL REVIEW ALL CONTRACT DOCUMENTS, INCLUDING SPECIFICATIONS, OF INTERFACING TRADES AND OTHER RELATED CONTRACTS PRIOR TO BIDDING AND COMMENCEMENT OF WORK TO ENSURE COMPLETE COORDINATION OF FINISHED WORK. 12. EACH SUBCONTRACTOR IS RESPONSIBLE TO COORDINATE AND SCHEDULE THEIR WORK WITH THE GENERAL CONTRACTOR AND ALL OTHER CONTRACTORS WHO'S WORK WILL BE AFFECTED. SPECIFICATIONS ARE APPLICABLE AND BINDING TO ALL CONTRACTORS AND SUBCONTRACTORS. REPORT ANY DISCREPANCIES, PRIOR TO CONSTRUCTION, TO THE OWNER'S REPRESENTATIVE OR ARCHITECT/ ENGINEER FOR REVIEW AND CLARIFICATION. 13. BEFORE AWARD OF CONTRACT, IF THERE ARE QUESTIONS ABOUT INTENT, CLARITY, APPLICATION OF NOTES, OR WORK SHOWN OR SPECIFIED, OR IF CONFLICTING DIRECTIONS ARE FOUND IN THE DOCUMENTS, THE GENERAL CONTRACTOR SHALL REQUEST WRITTEN CLARIFICATION FROM THE OWNER'S REPRESENTATIVE OR ARCHITECT/ ENGINEER. ANY CLARIFICATIONS OR INTREPRETATIONS OF THE CONTRACT DOCUMENTS PROVIDED AFTER CONTRACT AWARD SHALL BE AT NO ADDITIONAL COST. 14. CONTRACTOR SHALL NOT SCALE DRAWINGS FOR CONSTRUCTION PURPOSES. IN THE EVENT OF AN OMMISSION OF NECESSARY DIMENSIONS OR INFORMATION, CONTRACTOR SHALL NOTIFY THE OWNER'S REPRESENTATIVE OR ARCHITECT/ ENGINEER. FIGURED AND CALCULATED DIMENSIONS TAKES PRECEDENCE OVER SCALED MEASUREMENTS. DETAIL DRAWINGS AND LARGER SCALE DRAWINGS TAKES PRECEDENCE OVER SMALLER SCALE DRAWINGS. ALL PLAN DETAILS AND WALL SECTIONS ARE ASSUMED TO BE TYPICAL CONDITIONS UNLESS DETAILED OR NOTED OTHERWISE. 15. SOME STANDARD SYMBOLS, ABBREVIATIONS AND DETAILS INDICATED IN CONTRACT DOCUMENTS MAY NOT BE APPLICABLE TO THIS SPECIFIC CONTRACT ISSUE. 16. DRAWING DETAILS ARE CONCEPTUAL IN NATURE AND ACTUAL FIELD CONDITIONS MAY VARY SLIGHTLY FROM CONCEPTUAL DEPICTIONS. DETAILS LABELED "TYPICAL DETAILS" ON DRAWINIGS APPLY TO SITUATIONS THAT ARE THE SAME OR SIMILAR TO THOSE SPECIFICALLY DETAILED. SUCH DETAILS APPLY WHETHER OR NOT DETAILS ARE REFERENCED AT EACH LOCATION 17. SUBSTITUTIONS ARE SUBJECT TO THE APPROVAL OF THE OWNER. IF A SUBSTITUTION IS PROPOSED, SUBMIT COMPLETE SPECIFICATION AND PERFORMANCE DETAILS FOR EVALUATION. IF SUBSTITUTIONS ARE APPROVED, NOTIFY ALL OTHER CONTRACTORS AND SUBCONTRACTORS AFFECTED BY THE CHANGE AND FULLY COORDINATE ALL RELATED WORK. ANY COSTS RESULTING FROM THE SUBSTITUTION AND CHANGE IS THE RESPONSIBILITY OF THE CONTRACTOR. 18. COORDINATE AND PERFORM WORK BASED ONLY ON REVIEWED/ CERTIFIED SHOP DRAWINGS, A FIELD CHECK OF EXISTING CONDITIONS, AND INSPECTION OF NEWLY INSTALLED WORK. VERIFY THE LATEST REVISION OF CONTRACT DOCUMENTS, INCLUDING ALL INTERFACING DISCIPLINE DRAWINGS, BEFORE PROCEEDING WITH THE PROCUREMENT, DETAILING, FABRICATION OR INSTALLATION OF THE WORK. ANY SYSTEMS OR EQUIPMENT INSTALLED PRIOR TO REVIEW OF SHOP DRAWINGS BECOMES THE RESPONSIBILITY OF THE CONTRACTOR. 19. ALL EQUIPMENT SHALL BE INSTALLED IN FULL ACCORDANCE WITH MANUFACTURER'S DATA AND INSTALLATION INSTRUCTIONS. IT IS THE CONTRACTOR'S RESPONSIBILTY TO CHECK AND CONFORM TO MANUFACTURER SPECIFICATIONS AND REQUIREMENTS PRIOR TO STARTING THE WORK. VERIFY SIZE, LOCATIONS AND CHARACTERISTICS OF ALL EQUIPMENT TO BE FURNISHED WITH MANUFACTURER OR SUPPLIERS BEFORE COMMENCEMENT OF CONSTRUCTION. VERIFY SIZE AND LOCATIONS OF ALL OPENINGS AND SUPPORTS WITH ACTUAL EQUIPMENT PURCHASED. REFER TO MANUFACTURERS STANDARD DETAILS FOR INSTALLATION. 20. ALL EQUIPMENT AND SYSTEMS SHALL BE COMPLETE AND OPERATIONAL IN ALL RESPECTS, SECURED IN LOCATION AND PROPERLY ADJUSTED. PROVIDE OPERATIONS AND MAINTENANCE MANUALS FOR THE OWNER AT THE COMPLETION OF THE WORK. 21. FULLY WARRANT ALL MATERIALS, EQUIPMENT AND WORKMANSHIP FOR ONE (1) YEAR FROM DATE OF ACCEPTANCE, UNLESS OTHERWISE SPECIFIED. REPAIR OR REPLACE WITHOUT CHARGE TO THE OWNER ALL ITEMS FOUND DEFECTIVE DURING THE WARRANTY PERIOD. 22. BEFORE PENETRATING EXISTING CONCRETE OR SOIL SURFACES, CONSULT WITH ALL LOCAL UTILITIES' PROGRAMS FOR THE AREA OF WORK AND VERIFY LOCATION OF ALL EXISTING UNDERGROUND UTILITIES AND STRUCTURES BY USE OF "ELECTRONIC" OR SIMILAR NON-INVASIVE DETECTOR DEVICES. IF POTENTIAL INTERFERENCES ARE DISCOVERED, PROPOSE ALTERNATE ROUTING AND ASSOCIATED COSTS TO THE OWNER'S REPRESENTATIVE OR ARCHITECT/ENGINEER FOR APPROVAL BEFORE PROCEEDING. 23. MAINTAIN MINIMUM CLEARANCE REQUIREMENTS OF EQUIPMENT MANUFACTURER'S SPECIFICATIONS OR RECOMMENDATIONS, OWNER STANDARDS, NATIONAL ELECTRICAL CODE (NEC), AND ALL APPLICABLE FEDERAL, STATE AND LOCAL CODES, AND REGULATIONS. 24. MAINTAIN A MINIMUM OF 6' 8" HEADROOM CLEARANCE FOR BULKHEADS, SUPPORTS AND UTILITIES PASSING OVER WALKWAYS, PLATFORMS OR CATWALKS. ARCHITECTURAL NOTES: 25. ALL FINISH FLOOR ELEVATIONS ARE FOR ARCHITECTURAL PURPOSES ONLY. REFER TO CIVIL AND STRUCTURAL DRAWINGS FOR ACTUAL ELEVATIONS AND RELATIONSHIP TO SITE BENCHMARKS. 26. COORDINATE WITH MECHANICAL CONTRACTOR THE LOCATIONS OF ALL FLOOR DRAINS. 27. TRANSITION OF DIFFERENT FLOORING MATERIALS AT DOORWAYS SHALL OCCUR AT CENTERLINE OF DOORS AND SHALL BE Y2" HIGH MAXIMUM. 28. ALL PLAN DIMENSIONS ARE TO FINISHED FACE OF FINISHED WALLS, FACE OF MASONRY, AND CENTERLINE OF COLUMNS, UNLESS NOTED OTHERWISE. 29. PARTITIONS ARE TO EXTEND AND SEAL AGAINST THE BOTTOM OF THE DECK ABOVE UNLESS OTHERWISE NOTED. 30. INSTALL METAL TRIM ON ALL GYPSUM BOARD EDGES ABUTTING OTHER MATERIALS OR WHERE GYP BD STOPS SHORT OF OTHER MATERIALS TO FORM A REVEAL OR RECESS. USE METAL CORNER BEAD ON ALL GYPSUM BOARD EXTERIOR CORNERS. 31. ADD SUFFICIENT BLOCKING IN STUD WALLS TO SUPPORT ALL ITEMS OR EQUIPMENT SHOWN OR SPECIFIED TO BE ATTACHED TO WALLS. PROVIDE ADDITQNAL STRUCTURAL SUPPORT (PLATES, ANGLES, CHANNELS, ETC.) WITHIN WALLS WHERE WEIGHT OF ATTACHED ITEMS EXCEED WALL CAPACITY. PROVIDE BACKING PLATES OR BLOCKING FOR ANY OWNER FURNISHED OR INSTALLED ITEMS. - 32. PAINT ALL WALL SURFACES, DOOR FRAMES, BULKHEADS AND CEILINGS IN ROOMS WHERE INDICATED ON PLANS OR ROOM FINISH SCHEDULE. PAINT BEHIND ALL MOVEABLE ITEMS ADJACENT TO WALLS RECEIVING PAINT AND RELOCATE ITEMS AS NECESSARY. 33. ALL EXTERIOR SURFACES TO HAVE A TEMPORARY OR PERMANENT WEATHER RESISTIVE BARRIER DURING CONSTRUCTION OPERATIONS TO PROTECT THE BUILDING INTERIOR AND WALL SURFACES. EXTERIOR OPENINGS SHALL BE FLASHED IN SUCH A MANNER AS TO MAKE THEM WATERPROOF. 34. THE AREA OF WORK SHALL BE MAINTAINED WEATHERTIGHT AND IN A SECURED CONDITION AT ALL TIMES. THE CONTRACTOR SHALL TAKE ALL PRECAUTIONS NECESSARY TO SECURE THE AREA OF WORK. 35. REFER TO FLOOR AND REFLECTED CEILING PLANS AND MECHANICAL AND ELECTRICAL DRAWINGS FOR SPACE ALLOCATIONS IN ROUTING OF ALL MECHANICAL AND ELECTRICAL WORK INCLUDING DIFFUSERS, REGISTERS, GRILLES, LIGHTS, ETC. THE REFLECTED CEILING PLAN LOCATIONS SHALL BE ADHERED TO UNLESS OTHERWISE NOTED ON DRAWINGS. EXCEPTIONS SHALL REQUIRE SPECIFIC WRITTEN APPROVAL BY THE OWNER'S REPRESENTATIVE OR ARCHITECT/ ENGINEER. NOTE THAT ELECTRIC LIGHT FIXTURE LOCATIONS AND FIRE SPRINKLER HEADS SHALL TAKE PRECEDENCE OVER OTHER UTILITY ITEMS IN ANY AND ALL LOCATIONS FOR AREAS WITH OR WITHOUT CEILINGS; THE CONTRACTOR SHALL COORDINATE AS REQUIRED, AND IF THERE IS NO APPARENT SOLUTION TO COORDINATION ISSUE, CONTACT THE OWNER'S REPRESENTATIVE OR ARCHITECT/ ENGINEER FOR A RESOLUTION. 36. REFER TO STRUCTURAL DRAWINGS FOR SUPPORT STRUCTURE INFORMATION, DETAILS AND DIMENSIONS NOT INDICATED ON THE ARCHITECTURAL DRAWINGS. REPORT ANY DISCREPANCIES BETWEEN THE ARCHITECTURAL AND STRUCTURAL DRAWINGS TO THE ARCHITECT/ ENGINEER OR OWNER'S REPRESENTATIVE, PRIOR TO CONSTRUCTION. 37. COORDINATE MECHANICAL AND ELECTRICAL EQUIPMENT CONCRETE PADS AND ROOF CURB LOCATIONS, SIZES, SUPPORTS AND CONSTRUCTION REQUIREMENTS, ONLY WITH REVIEWED AND CERTIFIED SHOP DRAWINGS OF THE RELATED TRADES. 38. REFER TO AND COORDINATE WITH STRUCTURAL DRAWINGS FOR ALL FLOOR AND EXTERIOR WALL PENETRATIONS. INSULATE AND WATERTIGHT SEAL ALL EXTERIOR WALL PENETRATIONS. 39. REFER TO MECHANICAL AND ELECTRICAL DRAWINGS AND THE SPECIFICATIONS FOR WALL, FLOOR AND BUILDING SURFACES PENETRATION AND SEALING REQUIREMENTS. FIRE STOP ALL PENETRATIONS OF FIRE RATED WALL OR FIRE RATED FLOOR OPENINGS PER TESTED UL ASSEMBLIES AND AS REQUIRED BY CODE. 40. PROVIDE WALL AND CEILING ACCESS DOORS AS MAY BE REQUIRED BY CODE OR TO PROPERLY SERVICE OR ADJUST ALL VALVES, DAMPERS, CLEAN OUTS, ELECTRICAL JUNCTION BOXES AND OTHER DEVICES. DEMOLITON NOTES: 41. PLAN AND SCHEUDLE CONSTRUCTION AND DEMOLITION ACTIVITIES TO AVOID INTERFERENCE AND TO MINIMIZE DISRUPTION OF THE OWNER'S OPERATIONS. 42, SCHEDULE AND COORDINATE ALL DEMOLITION WORK AND UTILITY SHUT DOWNS AND TIE INS WITH THE OWNERS REPRESENTATIVE. PROCEED WITH WORK ONLY AFTER RECEIPT OF WRITTEN AUTHORIZATION. 43. DEMOLISHED MATERIALS, UNLESS OTHERWISE DIRECTED, SHALL BECOME THE PROPERTY OF THE CONTRACTOR AND SHALL BE PROMPTLY REMOVED FROM THE SITE BEFORE THE END OF EACH WORKDAY. OWNER RETAINED SALVAGED EQUIPMENT SHALL BE PROPERLY PROTECTED FOR REUSE OR CRATED FOR PROTECTION AND DELIVERED TO THE OWNER'S SITE STORAGE. ALL HAZARDOUS AND NON -HAZARDOUS MATERIALS SHALL BE PROPERLY DISPOSED OF OFF SITE AND PER ALL APPLICABLE FEDERAL, STATE AND LOCAL CODES. 44. PERFORM CONSTRUCTION AND SELECTIVE DEMOLITION IN A MANNER TO PREVENT DAMAGE TO ANY EXISTING AND NEW STRUCTURES, UTILITIES AND OTHER PROPERTY.. 45. ALL CUTTING AND CHASING OF BUILDING CONSTRUCTION SHALL BE IN A NEAT AND WORKMANLIKE MANNER. NEATLY SAWCUT ALL RECTANGULAR OPENINGS, SET SLEEVES THROUGH OPENINGS, AND FINISH PATCH OR PROVIDE TRIM AROUND OPENINGS. CORE DRILL AND SLEEVE ALL ROUND OPENINGS. 46. REPAIR SURFACES THAT HAVE BEEN DAMAGED BY THE WORK. REPAIR DAMAGE TO MATCH EXISTING CONSTRUCTION, INCLUDING BUT NOT LIMITED TO WEATHER AND FIRE SEALING, INSULATING, PATCHING AND PAINTING TO MATCH. MISCELLANEOUS SUPPORT RELATED NOTES; 47. PROVIDE SUPPLEMENTARY OR MISCELLANEOUS STEEL FOR SUPPORT, SWAY BRACING, CROSS BRACING, AND ANCHORAGE OF BUILDING SYSTEMS OR UTILITIES, IN ORDER TO MEET SITE SEISMIC AND SYSTEM SPECIFIC INSTALLATION AND OPERATING CONDITIONS. 48. COORDINATE SUPPLEMENTARY OR MISCELLANEOUS STEEL WITH THE PRIMARY STRUCTURAL STEEL WORK. SUPPORT, BRACE, CROSS BRACE, GUIDE AND ANCHOR AS REQUIRED SO AS TO IMPOSE NO OVERSTRESSING OF THE BUILDING STRUCTURE BEYOND STATED LOADS INDICATED ON THE STRUCTURAL DRAWINGS. 49. DO NOT WELD TO, CUT OR DRILL BUILDING STEEL. 50. DO NOT WELD SUPPLEMENTARY OR MISCELLANEOUS STEEL TO BUILDING STEEL WITHOUT PRIOR WRITTEN APPROVAL OF PROPOSED DETAIL BY THE STRUCTURAL ENGINEER, WELDING TO SUPPLEMENTARY STEEL IS PERMITTED. 51. DO NOT HANG SUPPORTS FROM TOP CHORD OF TRUSS. USE ONLY APPROVED BEAM CLAMPS, C CLAMPS ARE PROHIBITED. CONSULTANT: SEAL: JOHN BENEDICT POLSINELLI, AR96059 THIS DRAWING SHALL NOT BE USED FOR CONSTRUCTION PURPOSES UNTIL THE SEAL AND SIGNATURE OF THE RESPONSIBLE REGISTRANT APPEARS ON THE DRAWING, AND PROPER PERMIT FORMS AND RELATED FEES ARE TRANSMITTED BY THE OWNER, OWNER'S AGENT OR CONTRACTOR TO THE AUTHORITY HAVING JURISDICTION. DATE ISSUED FOR REV 09/27/201 8 PEMB COORDINATION 1 1 /27/201 8 OWNER REVIEW 1 2/1 8/201 8 PERMIT SUBMITTAL Project Manager Drawn L. LONG B. JACKSON Project Leader Checked L. LONG G. KARANFILOVSKI Date Dept Mgr Approval 08/07/2018 G. KARANFILOVSKI Client PALMETTO ZEPHYRHILLS-20th St, LLC P.O. BOX 161 5 THOMASVILLE., GA 31 792 Office: (229) 226-0682 Contact: John Tate Project DOLLAR GENERAL 38965 CR 54 Zephyrhills, FL 33542 (City of Zephyrhills) Store #: 20360 Drawing Title GENERAL NOTES DO NOT SCALE DRAWING Project No. Drawing No. JCDT.18.0233 Al ARCHITECTURAL SPECIFICATIONS GENERAL INFORMATION A. GENERAL 1 . CONFORM TO ALL GENERAL AND SPECIAL CONDITIONS OF CONTRACT AS SPECIFIED BY ARCHITECT AND OWNER. 2. SPECIFICATIONS ARE APPLICABLE TO ALL CONTRACTORS AND/OR SUBCONTRACTORS. 3. CHECK OTHER PLANS AND SPECIFICATIONS AND FULLY COORDINATE WITH OTHER SYSTEMS ON GRADES. 4. VISIT SITE, CHECK FACILITIES AND CONDITIONS, VERIFY ALL UTILITY CONNECTIONS, AND TAKE ALL ITEMS INTO CONSIDERATION IN BID. S. SYSTEMS ARE TO BE COMPLETE AND WORKABLE IN ALL RESPECTS, PLACED IN OPERATION AND PROPERLY ADJUSTED. 6. EACH CONTRACTOR SHALL PROVIDE FOR HIS OWN CLEAN UP, REMOVAL AND LEGAL DISPOSAL OF ALL RUBBISH ON A DAILY BASIS. 7. FULLY COORDINATE ALL WORK AND COOPERATE COMPLETELY WITH OTHER CONTRACTORS, SUBCONTRACTORS AND OWNER. 8. CONTRACTORS MUST CONFIRM ALL UTILITY CONNECTION POINTS IN FIELD, PRIOR TO STARTING WORK. 9. ARRANGE FOR AND OBTAIN OWNER'S PERMISSION FOR ANY SERVICE SHUTDOWNS REQUIRED UNDER THIS CONTRACT. 10. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, SEQUENCES OF CONSTRUCTION, AND THE SAFETY OF WORKERS. B. CODES, STANDARDS AND REGULATIONS 1 . CONFORM TO ALL APPLICABLE CODES AND GOVERNMENT REGULATIONS. 2. OBTAIN PERMITS AND PAY ALL FEES. ARRANGE FOR ALL REQUIRED INSPECTIONS AND APPROVALS. 3. REVIEW FOR THE GENERAL BUILDING PERMIT WILL BE OBTAINED BY THE ARCHITECT. PERMIT FEE IS BY THE CONTRACTOR. C. BASE EQUIPMENT, MATERIALS AND SUBSTITUTIONS 1 . ALL EQUIPMENT AND MATERIALS SHALL BE NEW AND FREE OF DEFECTS. 2. BASE EQUIPMENT MANUFACTURER, MODEL, AND CAPACITY OF EQUIPMENT ARE LISTED ON THE DRAWINGS OR IN THIS SPECIFICATION. ANY OTHER MANUFACTURER IS CONSIDERED A SUBSTITUTION. 3. SUBSTITUTIONS ARE SUBJECT TO THE APPROVAL OF THE OWNER. IF A SUBSTITUTION IS SUBMITTED, INCLUDE COMPLETE PERFORMANCE FACTS FOR EVALUATION. 4, IF SUBSTITUTIONS ARE APPROVED, NOTIFY ALL OTHER CONTRACTORS, SUBCONTRACTORS OF TRADES AFFECTED BY SUBSTITUTION AND FULLY COORDINATE. ANY COSTS RESULTING FROM SUBSTITUTION, WHETHER BY CONTRACTORS OR OTHERS, SHALL BE RESPONSIBILITY OF AND PAID FOR BY SUBSTITUTING CONTRACTOR. 5. ALL EQUIPMENT SHALL BE INSTALLED IN FULL ACCORDANCE WITH THE MANUFACTURER'S DATA AND INSTALLATION INSTRUCTIONS. IT IS THE CONTRACTOR'S RESPONSIBILITY TO CHECK AND CONFORM TO THESE REQUIREMENTS PRIOR TO STARTING WORK. D. CUTTING. PATCHING AND DRILLING 1 . ALL CUTTING AND CHASING OF THE BUILDING CONSTRUCTION AS REQUIRED SHALL BE IN A NEAT AND PROFESSIONAL MANNER. 2. NEATLY SAW CUT ALL RECTANGULAR OPENINGS, SET SLEEVE THROUGH OPENING, AND FINISH PATCH OR PROVIDE TRIM FLANGE AROUND OPENING 3. CORE DRILL AND SLEEVE ALL ROUND OPENINGS. 4. DO NOT CUT ANY STRUCTURAL COMPONENTS WITHOUT ARCHITECT'S APPROVAL. 5. PATCH AND FINISH TO MATCH ADJACENT AREAS THAT HAVE BEEN CUT, DAMAGED OR MODIFIED AS A RESULT OF THE INSTALLATIONS OF THE MECHANICAL OR ELECTRICAL EQUIPMENT. FIRE STOP ALL PENETRATIONS OF FIRE RATED CONSTRUCTION IN A CODE APPROVED MANNER. E. WARRANTY 1 . PROVIDE FULL WARRANTY ON ALL MATERIALS, EQUIPMENT AND WORKMANSHIP FOR ONE (1) YEAR FROM DATE OF ACCEPTANCE, UNLESS NOTED OTHERWISE. 2. EXTEND ALL MANUFACTURER'S WARRANTIES TO OWNER, INCLUDING FIVE (5) YEAR HEAT EXCHANGER EXTENDED WARRANTY ON HVAC EQUIPMENT 3. REPAIR OR REPLACE WITHOUT CHARGE TO THE OWNER ALL ITEMS FOUND DEFECTIVE DURING THE WARRANTY PERIOD. F. SHOP DRAWINGS 1 . PROVIDE JOB SPECIFIC INFORMATION ON REPRODUCIBLE SHEETS WITH GRAPHIC INFORMATION AT ACCURATE SCALE. CONTRACTOR IS RESPONSIBLE TO CHECK ALL SUBMITTALS. 2. PROVIDE SUBMITTALS FOR THE FOLLOWING ITEMS: A) CONCRETE DESIGN MIX. B) ALL STRUCTURAL & MISCELLANEOUS STEEL C) MASONRY & ACCESSORIES D) METAL GUTTER & DOWNSPOUTS (-( KICPFTF SECTION 03300 - CAST IN PLACE CONCRETE REFER TO STRUCTURAL DRAWINGS MASONRY SECTION 04800 1. INTEGRAL WATER REPELLANT: PROVIDE UNITS MADE WITH INTEGRAL WATER REPELLENT FOR EXPOSED UNITS. 1 .l . PROVIDE PRODUCT FROM ONE OF THE FOLLOWING OR AS APPROVED EQUAL: 1 A .1 . W.R. GRACE & CO., DRY -BLOCK BLOCK ADMIXTURE. 1 .1 .2. MASTER BUILDERS, RHEOPEL PLUS MULTI -PURPOSE ADMIXTURE. 2. WATER-REPELLENT ADMIXTURE: LIQUID WATER-REPELLENT MORTAR ADMIXTURE INTENDED FOR USE WITH CMUs CONTAINING INTEGRAL WATER REPELLENT FROM SAME MANUFACTURER. 2.1. PROVIDE PRODUCT FROM ONE OF THE FOLLOWING OR AS APPROVED EQUAL. 2.1 .1 . W.R. GRACE & CO., DRY -BLOCK MORTAR ADMIXTURE. 2.1.2. MASTER BUILDERS, RHEOPEL PLUS MORTAR ADMIXTURE. 3. JOB -MIXED DETERGENT SOLUTION: CLEAN THE COMPLETED WALLS WITH PROSOCO BURNISHED CUSTOM MASONRY CLEANER (DILUTE 1 PART TO 3 PARTS CLEAN WATER), STRICTLY FOLLOWING THE MANUFACTURER'S INSTRUCTIONS - INCLUDING THOROUGH RINSING. DO NOT USE ACID OR ABRASIVES ON THE FINISHED SURFACES. FAILURE TO STRICTLY FOLLOW MANUFACTURER'S INSTRUCTIONS CAN RESULT IN PERMANENT DAMAGE TO THE FINISHED FACES. DO NOT APPLY BURNISHED CUSTOM MASONRY CLEANER WITH PRESSURE SPRAY ABOVE 50 PSI. DO NOT POWERWASH. 4. INSTALL MASONRY UNITS AS INDICATED ON THE DOCUMENTS. THESE UNITS SHALL INCLUDE, BUT NOT BE LIMITED TO REGULAR CONCRETE BLOCK. 5. PROVIDE COLD WEATHER PROTECTION WHEN WEATHER CONDITIONS DICTATE. 6. MASONRY UNITS SHALL BE REINFORCED WITH TRUSS TYPE REINFORCING PER ASTM Al 53. 7. CONTRACTOR IS RESPONSIBLE TO INSTALL ALL NECESSARY ITEMS INCLUDING STEEL LINTELS, ANCHORS, REINFORCING, ETC., AND ALL OTHER ITEMS NECESSARY FOR A COMPLETE INSTALLATION. 8. MASONRY SHALL BE MINIMUM 2000 PSI - NORMAL WEIGHT AND MEET ASTM C 90. MORTAR SHALL BE TYPE "S" AND SHALL MEET ASTM. C270, COLOR AS SCHEDULED ON EXTERIOR FINISH SCHEDULE. 8. FLASHING, WEEP HOLES, AND VENTS: GENERAL: INSTALL EMBEDDED FLASHING AND WEEP HOLES IN MASONRY AT SHELF ANGLES, LINTELS, LEDGES, OTHER OBSTRUCTIONS TO DOWNWARD FLOW OF WATER IN WALL, AND WHERE INDICATED. EXTEND FLASHING 4 INCHES AT ENDS AND TURN FLASHING UP NOT LESS THAN 2 INCHES TO FORM A PAN. INSTALL METAL DRIP EDGES BENEATH FLASHING AT EXTERIOR FACE OF WALL 9. STOP FLASHING 1 /2 INCH BACK FROM OUTSIDE FACE OF WALL AND ADHERE FLASHING TO TOP OF METAL DRIP EDGE. 10. INSTALL METAL FLASHING TERMINATION BENEATH FLASHING AT EXTERIOR FACE OF WALL. 1 1 . STOP FLASHING 112 INCH BACK FROM OUTSIDE FACE OF WALL AND ADHERE FLASHING TO TOP OF METAL FLASHING TERMINATION. 12. PROVIDE SINGLE WYTHE CONCRETE MASONRY UNIT DRAINAGE SYSTEM USING BLOK-FLASH, MANUFACTURED BY MORTAR NET USA. 13. DRAINAGE SYSTEM INCLUDES PAN, INTEGRATED WEB SPACER/BRIDGE AND DRAINAGE MAT. FOLLOW MANUFACTURER'S SPECIFICATIONS FOR HANDLING AND INSTALLATION. 14. FOR VERTICAL AND HORIZONTAL REINFORCING REF TO STRUCTURAL DRAWINGS. 15. COAT EXTERIOR BLOCK WITH CLEAR PROSOCO SILOXANE WB MASONRY SEALER IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS, COVERAGE RATES AND SPECIFICATIONS. METALS SECTION 05120 STRUCTURAL STEEL REFER TO STRUCTURAL DRAWINGS. SECTION 05400 COLD FORMED METALS REFER TO STRUCTURAL DRAWINGS SECTION 05500 1. METAL FABRICATIONS PROVIDE AND INSTALL ALL ITEMS MADE FROM IRON AND STEEL SHAPES, PLATES, BARS, STRIPS, TUBES, PIPES AND CASTINGS WHICH ARE NOT A PART OF THE STRUCTURAL STEEL OR OTHER METAL SYSTEMS SPECIFIED ELSEWHERE. 2. THESE SHALL INCLUDE, BUT NOT NECESSARILY BE LIMITED TO THE FOLLOWING: 2.a. LOOSE STEEL LINTELS. 2.b. LOOSE BEARING AND LEVELING PLATES. 2.c. MISCELLANEOUS FRAMING AND SUPPORTS. 2.d. STEEL BOLLARDS (SCHEDULE 40) 2.e. DOWNSPOUT GUARDS 3. ALL FERROUS METALS SHALL BE SHOP PRIMED AND FIELD TOUCHED UP. 4. PROVIDE A ZINC COATING FOR ITEMS EXPOSED TO THE EXTERIOR. 5. ALSO, PROVIDE ZINC COATING FOR ANY STEEL INSIDE EXTERIOR MASONRY WALLS. CARPENTRY SECTION 06100 1 . ROUGH CARPENTRY PROVIDE AND INSTALL ALL WORK NECESSARY FOR ROUGH CARPENTRY INCLUDING: WOOD GROUNDS, NAILERS, AND BLOCKING. WOOD FURRING & FRAMING. 2. ROOF PLATES AND CANTS. ALL WOOD BLOCKING, NAILERS, PLATES AND PLYWOOD SHALL BE EXTERIOR GRADE, CHEMICALLY FIRE RETARDANT TREATED. 3. ALL WOOD IN CONTACT WITH MASONRY OR CONCRETE SHALL COMPLY WITH APPLICABLE STANDARDS FOR PRESERVATIVE TREATMENT LUMBER. (LUMBER AWPA C2). SECTION 06200 FINISH CARPENTRY PROVIDE ALL LABOR, MATERIALS, SERVICE AND EQUIPMENT NECESSARY FOR ALL FINISH CARPENTRY WORK, INCLUDING, BUT NOT LIMITED TO: INSTALLATION OF DOORS AND HARDWARE. THERMAL & MOISTURE PROTECTION SECTION 07200 1 . INSULATION PROVIDE ALL LABOR, MATERIALS, SERVICES AND EQUIPMENT NECESSARY FOR INSULATION WORK TO INCLUDE BUT NOT NECESSARILY BE LIMITED TO: INSULATION SHALL BE EXTRUDED POLYSTYRENE BOARD INSULATION FOR USE BELOW GRADE. 2, SEE WALL SECTIONS FOR INSULATION THICKNESS. FOAMED -IN -PLACE MASONRY INSULATION SHALL BE CORE -FILL 500 MANUFACTURED BY TAILORED CHEMICAL PRODUCTS -OR- APPROVED EQUAL 3. INSTALLATION SHALL BE PER MANUFACTURER'S INSTRUCTIONS. EXTERIOR INSULATION AND FINISH SYSTEM (E.I.F.S.) SECTION 07240 1 . PROVIDE ALL LABOR, MATERIALS, SERVICES AND EQUIPMENT NECESSARY FOR ALL WORK INCLUDED FOR THE EXTERIOR INSULATED AND FINISH WALL SYSTEM DENS GLASS GOLD SHEATHING (AT METAL STUD FRAMING), RIGID MOLDED CELLULAR INSULATION, ADHESIVE, REINFORCING FABRIC, BASE COAT, FINISH COAT AND ALL ACCESSORIES. 2. PROVIDE CLASS PB EIFS CONSISTING OF FABRIC SHALL BE ALKALI RESISTANT, OPEN WEAVE FIBER FABRIC WITH TENSILE STRENGTH OF NOT LESS THAN 200 LBS. MANUFACTURER: STO CORP (888)786-3437; STOTHERM LOTUSAN NEXT SYSTEM -OR- APPROVED EQUAL FLASHING AND SHEET METAL SECTION 07600 1 . PROVIDE ALL LABOR, MATERIALS, SERVICES AND EQUIPMENT NECESSARY TO COMPLETE ALL WORK ASSOCIATED WITH FLASHING AND SHEET METAL TO INCLUDE, BUT NOT LIMITED TO: METAL FLASHING AND COPINGS METAL COUNTERFLASHINGS AND REGLETS. GUTTERS, DOWNSPOUTS AND SCUPPER. 2. MISCELLANEOUS SHEET METAL ACCESSORIES - METAL FLASHING AND COPINGS SHALL BE PREFINISHED G90 HOT DIPPED GALVANIZED STEEL, MINIMUM 22 GAUGE INTERLOCKING 2 PART TYPE CONSTRUCTION. 3. GUTTERS, AND DOWNSPOUTS SHALL BE PREFINISHED G90 HOT DIPPED -GALVANIZED STEEL, MINIMUM 22 GAUGE. 4. PROVIDE STRAPS AND BRACKETS AS REQUIRED. 5. GUTTER AND DOWNSPOUT SIZE AS NOTED ON THE DRAWINGS. 6. FINISH SHALL BE KYNAR 500 FLUOROCARBON COATING. COLOR AS NOTED ON THE DRAWINGS. STEEL DOORS AND FRAMES and DOORS AND WINDOWS SECTION 08110 1 . PROVIDE ALL LABOR AND MATERIALS, SERVICES AND EQUIPMENT NECESSARY TO COMPLETE ALL WORK ASSOCIATED WITH STEEL DOORS AND FRAMES. 2. HINGED DOOR AND FRAMES DESCRIBED HEREIN ARE FOR A MAX. OF 4 FT. WIDE AND 8 FT. 3. HIGH DOORS, COMPLYING WITH STEEL DOOR INSTITUTE (SDI) RECOMMENDED SPECIFICATIONS. 4. WHERE FIRE RATED DOOR ASSEMBLIES ARE INDICATED OR REQUIRED PROVIDE DOOR AND FRAME ASSEMBLIES THAT COMPLY WITH NFPA 80. 5. PROVIDE METAL FRAME FOR DOORS, FABRICATED WITH MITERED CORNERS. 6. FORM EXTERIOR FRAMES OF 16 GAUGE FOR 1-3/4" DOORS, FLUSH DOUBLE RABBETED TYPE WITH 5/8" DEEP STOPS IN 2" FACE. 7. CORNERS TO BE WELDED. 15. EXTERIOR DOORS SHALL BE GALVANIZED FLUSH TYPE WITH INSULATION, 16. INTERIOR FRAMES SHALL BE 18 GAUGE WITH KNOCK - DOWN CONSTRUCTION. 17. FURNISH JAMB ANCHORS NOT LESS THAN 3 PER JAMB, AS REQUIRED TO SECURE FRAMES TO ADJACENT CONSTRUCTION. FORMED OF NOT LESS THAN 18 GAUGE GALVANIZED STEEL. 18. EXCEPT ON WEATHER-STRIPPED FRAMES, DRILL STOPS TO RECEIVE 3 SILENCERS ON JAMB STRIKES OF FRAMES FOR SINGLE DOORS, 2 SILENCERS ON HEADS OF FRAMES FOR PAIR OF DOORS. 19. APPLY 3 MIL THICK BITUMINOUS COATING INSIDE OF BOTH INTERIOR AND EXTERIOR DOOR FRAMES THAT WILL BE FILLED WITH MORTAR. 20. INSTALL FINISH HARDWARE AS SPECIFIED IN DOOR HARDWARE SCHEDULE. WOOD DOORS SECTION 08210 PROVIDE ALL LABOR AND MATERIALS, SERVICES AND EQUIPMENT NECESSARY TO COMPLETE ALL WORK ASSOCIATED WITH SPECIAL DOORS. SOLID CORE WOOD DOORS SHALL HAVE BIRCH VENEER - STAIN GRADE WITH SOLID PARTICLE BOARD CORE PER ANSI A208.1 , GRADE LD-1. ALUMINUM DOOR ENTRANCES, STOREFRONTS AND GLASS SECTION 08410 1 . PROVIDE AND INSTALL ALUMINUM AND GLASS SLIDING DOOR SYSTEM AND STOREFRONT SYSTEM, AS INDICATED ON THE DRAWINGS. 2. INCLUDE ALL FRAMING, BRAKE METAL TRIM, SUPPORTS, CLIPS, BRACKETS, CLOSURES, ETC, AS REQUIRED FOR A COMPLETE STOREFRONT AND ENTRANCE N STALLATI O N . 3. ALLOW FOR EXPANSION AND CONTRACTION RESULTING FROM AMBIEN-i TEMPERATURE RANGE OF 120 DEGREES F. 4. PROVIDE CAPACITY TO MEET ALL REQUIRMENTS AS OUTLINE IN FLORDIA THE PRODUCT APPROVAL DESIGN GUIDELINES. S. INCLUDE TRANSOM FRAMING AS INDICATED ON THE DRAWINGS. 6. INCLUDE ALL SAFETY RAILS AND ACCESSORIES AS REQUIRED BY LOCAL AUTHORITIES. 7. ALL EXTERIOR STOREFRONT FRAMING SYSTEMS SHALL BE "THERMAL BREAK" CONSTRUCTION. KAWNEER SYSTEM "TRI-FAB 451-T" OR APPROVED EQUAL 8. ALUMINUM AND GLASS STOREFRONT SYSTEM SHALL COMPLY WITH THE PROVISIONS AAMA "METAL CURTAINWALL, WINDOW, STOREFRONT AND ENTRANCE GUIDESPECIFICATIONS MANUAL". 9. ALUMINUM MEMBERS SHALL MEET ASTM 8221 FOR EXTRUSIONS. 10. ASTM B209 FOR SHEET/PLATE. 1 1 . STEEL REINFORCEMENT SHALL BE HOT ROLLED TYPE MEETING ASTM A36. 12. BRAKE METAL SHALL BE 0,050 THICKNESS. PROVIDE 1" INSULATED UNITS AT EXTERIOR. 13. GLASS SHALL BE 1/4" THICK PANES WITH 1/2" AIR SPACE WITH A LOW-E COATING. 14. PROVIDE TEMPERED GLASS ADJACENT TO ENTRY DOORS OR AS REQUIRED BY LOCAL AUTHORITIES. INTERIOR GLASS SHALL BE 1 /4" TEMPERED GLASS 15. ALL GLASS SHALL BE CLEAR UNLESS OTHERWISE NOTED. 16. ALUMINUM FRAME & BRAKE METAL SHALL HAVE FINISH PER EXTERIOR FINISH SCHEDULE. 17. PROVIDE 1 /4" GLASS IN DOORS AS INDICATED IN THE DRAWINGS. FINISH HARDWARE SECTION 08710 1. PROVIDE LABOR, MATERIALS, SERVICES AND EQUIPMENT NECESSARY FOR COMPLETE INSTALLATION OF FINISH HARDWARE. 2. REFER TO THE DRAWINGS FOR ADDITIONAL ITEMS. FINISHES SECTION 09250 GYPSUM DRYWALL 1 . PROVIDE AND INSTALL GYPSUM DRYWALL AS INDICATED ON THESE DRAWINGS, AND PER ASTM C1 1 OR GA-505 BY THE GYPSUM ASSOCIATION. 2. PROVIDE GYPSUM BOARD AS INDICATED ON THESE DRAWINGS, AS MANUFACTURED BY DOMTAR GYPSUM AMERICA, INC., GOLD BOND BLDG. PRODUCTS, AND US GYPSUM CO. 3. GYPSUM BOARD INSTALLATION WILL BE ON METAL STUDS OR FURRING @ 16" ON CENTER UNLESS OTHERWISE NOTED. 4. ADJUST GAUGE AS REQUIRED FOR UNSUPPORTED LENGTH PER 5 PSF. 5. FOR LOADING REFER TO THE DRAWINGS FOR MINIMUM GAUGE. 6. INSTALL WATER RESISTANT GYPSUM BOARD, PER ASTM C30 AT TOILETS, SERVICE SINK, ALL SINKS AND FLOOR DRAIN AREAS. 7. PROVIDE MANUFACTURER'S STANDARD TRIM ACCESSORIES, INCLUDING BUT NOT LIMITED TO CORNER BEAD, L TYPE EDGES, TRIM BEDS, U TYPE EDGE TRIM BEAD, SPECIAL L CURVED TYPE EDGE TRIM BEAD AND ONE PIECE CONTROL JOINT BEAD.. 8. PROVIDE CONTROL JOINTS IN WALLS AT NOT MORE THAN 30' SPACING AND IN SOFFITS NOT EXCEEDING 50' SPACING, OR AS INDICATED ON THE DRAWINGS. 9. APPLY TREATMENT AT GYPSUM BOARD JOINTS, INCLUDING JOINT TAPE AT ALL JOINTS BETWEEN GYPSUM BOARDS AND MIN. 2 COATS GYPSUM JOINT COMPOUND (OMIT THIRD COAT AND SANDING ON CONCEALED DRYWALL WORK) 10. EXTERIOR GYPSUM SHEATHING - 5/8" DENS -GLASS GOLD PER ASTM. C79. - OR - APPROVED EQUAL ACOUSTIC CEILING & GRID • SECTION 009510 1 . INTERIOR ACOUSTIC CEILING TILES TO BE 5/8" x 24" x 48" STANDARD FISSURE TILE IN 1 5/16" WHITE GALVANIZED SUSPEND GRID. INSTALL PER MANUFACTURERS REQUIREMENTS. 2. EXTERIOR ACOUSTIC CEILING TO BE 5/8" x 24" x 48" EXTERIOR FISSURE TILE IN 1 5/16" WHITE GALVANIZED SUSPENDED GRID.. 3. ARMSTRONG - CERAMAGUARD OR EQUAL. 4. PROVIDE HOLD DOWN CLIPS. 5. INSTALL PER MANUFACTURERS REQUIREMENTS. PAINTING SECTION 09900 1. PROVIDE ALL LABOR AND MATERIALS AS NECESSARY FOR FINISHES AS INDICATED IN THESE SPECIFICATIONS. 2, ACCEPTABLE PAINT MANUFACTURERS INCLUDE: SHERWIN WILLIAMS, PPG, AND BENJAMIN MOORE 3. ALL FINISHES AND MATERIALS TO RECEIVE PAINT SHALL BE CLEANED THOROUGHLY AND PREPARED PER MANUFACTURES RECOMMENDATIONS. 4. INTERIOR DRYWALL 4.1. 1 COAT LATEX PRIMER 4.2. 2 COATS LATEX EGGSHELL 5. INTERIOR WOOD DOORS. 5.1. 1 COAT OPEN GRAIN WOOD FILLER 5.2. 2 COATS WOOD SATIN POLYURETHANE SEALER 6. INTERIOR HOLLOW METAL FRAMES AND DOORS 6.1. 1 COAT FACTORY PRIME COAT 6.2. 2 COATS SPREAD LUSTER SEMI -GLOSS ENAMEL 7. EXTERIOR METAL 7.1. 1 COAT PRIMER (IF NOT FACTORY PRIMED) 7.2. 2 COATS SPREAD LUSTER SEMI -GLOSS ENAMEL 8. SEE ROOM FINISH SCHEDULE SHEET A4 FOR SPECIFIC COLORS. CONSULTANT: SEAL: JOHN BENEDICT POLSINELLI, AR96059 THIS DRAWING SHALL NOT BE USED FOR CONSTRUCTION PURPOSES UNTIL THE SEAL AND SIGNATURE OF THE RESPONSIBLE REGISTRANT APPEARS ON THE DRAWING, AND PROPER PERMIT FORMS AND RELATED FEES ARE TRANSMITTED BY THE OWNER, OWNER'S AGENT OR CONTRACTOR TO THE AUTHORITY HAVING JURISDICTION. DATE ISSUED FOR REV 09/27/201 8 PEMB COORDINATION 11/27/2018 OWNER REVIEW 12/18/201 8 PERMIT SUBMITTAL Project Manager Drawn L. LONG B.JACKSON Project Leader Checked L. LONG G. KARANFILOVSKI Date Dept Mgr Approval 08/07/2018 G. KARANFILOVSKI Client PALMETTO ZEPHYRHILLS-20th St, LLC P.O. BOX 1615 THOMASVILLE, GA 31 792 Office: (229) 226-0682 Contact: John Tate Project DOLLAR GENERAL 38965 CR 54 Zephyrhills, FL 33542 (City of Zephyrhills) Store #: 20360 Drawing Title GENERAL NOTES AND ARCHITECTURAL SPECIFICATIONS DO NOT SCALE DRAWING Project No. Drawing No. JCDT.18.0233 Al2 0 GENERAL NOTES: 1. BUILDING AND DESIGN CODES: A. 2017 FLORIDA BUILDING CODE B. AISC 360-10: SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS (14TH EDITION STRUCTURAL STEEL MANUAL) C. S100-12: NORTH AMERICAN SPECIFICATION FOR THE DESIGN OF COLD -FORMED STEEL STRUCTURAL MEMBERS D. AWS STRUCTURAL STEEL WELDING CODE, D1.1-2010 E. ACI 318-14 BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE F. ACI DETAILING MANUAL, 2004 G. STRUCTURAL WELDED WIRE REINFORCEMENT MANUAL OF STANDARD PRACTICE, WIRE REINFORCEMENT INSTITUTE, 2011 H. ACI 530-1 3 BUILDING CODE REQUIREMENTS FOR MASONRY STRUCTURES I. CRSI MANUAL OF STANDARD PRACTICE, 2009 J. SDI CODE OF RECOMMENDED STANDARD PRACTICE FOR COMPOSITE DECK, FORM DECKS, AND ROOF DECK CONSTRUCTION, 2010 2. DESIGN LOADS: A. LIVE LOADS: UNIFORM ROOF 20 PSF SLAB ON GRADE 100 PSF LIVE LOAD REDUCTION ON SUPPORTING ELEMENTS IN ACCORDANCE WITH, BUILDING CODE B. DEAD LOADS: ROOF DEAD LOAD 12 PSF C. WIND LOADS: 3 SECOND GUST WIND SPEED: Vult = 137 MPH (Vasd = 106 MPH) EXPOSURE: C RISK CATEGORY: II D. SEISMIC LOADS: SEISMIC IMPORTANCE FACTOR: 1.00 OCCUPANCY CATEGORY: II Ss: SPECTRAL ACC FOR SHORT PERIOD = 0.084g Si: SPECTRAL ACC FOR 1 SECOND PERIOD = 0.034g SITE CLASS D SDS: DESIGN SPECTRAL ACC FOR SHORT PERIOD= 0.090g SDI : DESIGN SPECTRAL ACC FOR 1 SECOND PERIOD= 0.054g SEISMIC DESIGN CATEGORY A Fa = 1.6 Fv = 2.4 BASIC SEISMIC FORCE RESISTING SYSTEM: STRUCTURAL STEEL NOT SPECIFCALLY DETAILED FOR SEISMIC RESISTANCE DESIGN BASE SHEAR = 1.7 KIPS Cs = 0.01 R = 3.0 SEISMIC DESIGN PROCEDURE: EQUIVALENT LATERAL FORCE PROCEDURE E. SNOW LOADS Ce: EXPOSURE FACTOR = 1.0 Cr: THERMAL FACTOR = 1.0 Pg = GROUND SNOW LOAD = 0 PSF FOUNDATION: FOUNDATION DESIGN IS BASED UPON THE GEOTECHNICAL ENGINEERING REPORT ENTITLED "GEOTECHNICAL EXPLORATION" PROPOSED DOLLAR GENERAL STORE N.W. CORNER OF CR-54 AND 20TH ST ZEPHYRHILLS, FLORIDA PREPARED BY UNIVERSAL ENGINEERING SCIENCES DATED JULY 31, 2018 1. CONTRACTOR TO PROVIDE FOUNDATION & FOOTING AS REQUIRED FOR PYLON SIGN OR MONUMENTAL SIGN REF. SPECIFICATIONS 2. COORDINATE STRUCTURAL PLANS AND DETAILS WITH REQUIREMENTS OF GEOTECHNICAL REPORT FOOTING DESIGN IS BASED ON 2500 PSF ALLOWABLE SOIL BEARING PRESSURE. 3. CONTRACTOR SHALL TREAT SOIL BELOW SLAB FOR TERMITES PER 2017 FBC SECTION 18164. 4. REFER TO THE GEOTECHNICAL REPORT AND SPECIFICATIONS FOR GENERAL REQUIREMENTS OF EARTHWORK, OVEREXCAVATION, SUBGRADE PREPARATION, FILL AND COMPACTION, WATERPROOFING AND OTHER PERTINENT REQUIREMENTS AND INFORMATION. IF THERE IS A CONFLICT BETWEEN GEOTECHNICAL REPORT AND STRUCTURAL PLANS THEN THE MORE STRINGENT CRITERIA SHALL APPLY UNLESS OTHERWISE DIRECTED BY AN RFL. 5. PROTECT PIPES AND CONDUITS RUNNING THROUGH WALLS AND SLABS WITH 112 INCH EXPANSION MATERIAL. LOWER CONTINUOUS FOOTINGS AND GRADE BEAMS PERPENDICULAR TO PIPE RUNS TO ALLOW PIPES TO PASS ABOVE THE FOOTINGS OR THROUGH THE GRADE BEAMS. ALTERNATIVELY, PROVIDE A CONCRETE JACKET IF PIPES ARE LOW ENOUGH TO BE PLACED BELOW THE FOOTINGS AND GRADE BEAMS. LOWER FOOTINGS AND GRADE BEAMS PARALLEL TO PIPE RUNS TO AVOID SURCHARGE ONTO ADJACENT TRENCH EXCAVATIONS. 6. MAINTAIN SUBGRADE AND FILL MOISTURE CONTENT UNTIL FOUNDATIONS ARE PLACED. 7. ARRANGE FOR OWNER'S INDEPENDENT TESTING AGENCY TO MONITOR CUT AND FILL OPERATIONS AND PERFORM FIELD DENSITY AND MOISTURE CONTENT TESTS TO VERIFY COMPACTION AND APPROVE FOOTING SUBGRADES PRIOR TO PLACING CONCRETE. 8. DO NOT PLACE FOOTINGS OR SLABS AGAINST SUBGRADE CONTAINING FREE WATER, FROST, OR ICE. 9. MAINTAIN PROPER SITE DRAINAGE DURING CONSTRUCTION TO ENSURE SURFACE RUNOFF AWAY FROM STRUCTURES AND TO PREVENT PONDING OF SURFACE RUNOFF NEAR THE STRUCTURES. PAD PREPARATION: RE: GEOTECH REPORT CONCRETE: 1 . PROVIDE BATCH MIXING, TRANSPORTATION, PLACING AND CURING OF CONCRETE IN ACCORDANCE WITH RECOMMENDATIONS OF ACI 301 AND ACI 318. USE ASTM C 150 CEMENT UNLESS NOTED OTHERWISE. PROVIDE ADMIXTURES AND SPECIAL REQUIREMENTS AS SPECIFIED. A. ALL CONCRETE SHALL BE NORMAL WEIGHT (145 PCF) CONCRETE AND: f'c=4,000 PSI AT 28 DAYS FOR SLAB ON GRADE, FOUNDATIONS, AND CONTINUOS FTC THE CONCRETE FOR THE SLAB ON GRADE SHALL CONTAIN A MINIMUM OF 564 LBS PER CUBIC YARD OF PORTLAND CEMENT. FLY ASH IS NOT ALLOWED IN THE CONCRETE MIX DESIGN OF SLAB ON GRADE. THE CONCRETE AGGREGATE SHALL MEET ASTM C33, SHALL BE WELL GRADED AND CONTAIN A NOMINAL MAXIMUM AGGREGATE SIZE OF AT LEAST 3/4" 2. PREPARE AND SUBMIT MIXTURES FOR EACH CLASS OF CONCRETE ON THE BASIS OF LABORATORY TRIAL MIXTURES OR FIELD TEST DATA FOR REVIEW AND APPROVAL BY THE STRUCTURAL ENGINEER 3. PROVIDE CONSTRUCTION AND CONTROL JOINTS AS INDICATED ON DRAWINGS. HORIZONTAL CONSTRUCTION JOINTS ARE NOT ALLOWED UNLESS SPECIFICALLY NOTED OR APPROVED BY STRUCTURAL ENGINEER. NOTIFY STRUCTURAL ENGINEER OF PROPOSED CONSTRUCTION JOINT OR CONTROL JOINT LOCATIONS THAT ARE DIFFERENT OR IN ADDITION TO JOINTS INDICATED ON DRAWINGS. 4. CHAMFER EXPOSED EDGES 3/4 INCH UNLESS OTHERWISE NOTED. F. ADDITIONAL DESIGN LOADS (ASD) INDICATED ON STRUCTURAL DRAWINGS SHALL BE IDENTIFIED AS FOLLOWS: 5. WIRE BRUSH AND CLEAN CONSTRUCTION JOINTS PRIOR TO POURING NEW CONCRETE. DL = DEAD LOAD 6. REFERENCE THE APPROPRIATE DISCIPLINE DRAWINGS FOR SUBSLAB PIPING, FLOOR DRAINS LL = LIVE LOAD AND SLAB AND WALL PENETRATIONS. WL = WIND LOAD 7. PROVIDE ADEQUATE STRUCTURAL FRAMING AS APPROVED BY STRUCTURAL ENGINEER FOR EL = SEISMIC LOAD MECHANICAL OPENINGS THROUGH THE SLABS, WALLS AND FLOOR DECK. OPENINGS WILL NOT BE PERMITTED THROUGH BEAMS UNLESS SPECIFICALLY DETAILED. 3. GENERAL REQUIREMENTS: 8. ADMIXTURES:. A. AIR -ENTRAINING ADMIXTURE: ASTM C 260 A. SPECIFICATIONS ARE PART OF THE CONSTRUCTION DOCUMENTS AND MUST BE USED IN CONJUNCTION WITH THE DRAWINGS. B. WATER -REDUCING ADMIXTURE: ASTM C 494, TYPE A C. RETARDING ADMIXTURE: ASTM C 494 TYPE B B. VERIFY EXISTING CONDITIONS AND DIMENSIONS PRIOR TO BEGINNING WORK OR FABRICATING MATERIALS. NOTIFY A/E OF DISCREPANCIES BEFORE PROCEEDING WITH D. ACCELERATING ADMIXTURE: ASTM C 494 TYPE C ( NON CHLORIDE) ANY PHASE OF WORK. E. HIGH -RANGE, WATER REDUCING ADMIXTURE: ASTM C 494, TYPE F C. VERIFY THE LOCATION OF CHASES, INSERTS, OPENINGS, SLEEVES, FINISHES, F. WATER REDUCING AND ACCELERATING ADMIXTURE: ASTM C 494, TYPE E DEPRESSIONS, PADS, AND WALL OPENINGS. G. WATER REDUCING AND RETARDING ADMIXTURE: ASTM C 494, TYPE D H. OTHER ADMIXTURES FOR SPECIFIC USE WITH THE PERMISSION OF THE DESIGN PROFESSIONAL D. DO NOT SCALE DRAWINGS FOR THE PURPOSE OF ESTABLISHING DIMENSIONS. 9. COMPLY WITH RECOMMENDATIONS IN ACI 302.1 R FOR SCREEDING, RESTRAIGHTENING AND E. DETAILS LABELED "TYPICAL DETAILS' ON DRAWINGS APPLY TO SITUATIONS FINISHING OPERATIONS FOR CONCRETE SURFACES. DO NOT WET CONCRETE. OCCURRING ON THE PROJECT THAT ARE THE SAME OR SIMILAR TO THOSE SPECIFICALLY A. INTERIOR FLOOR SLABS: MACHINE TROWEL FINISH DETAILED. SUCH DETAILS APPLY WHETHER OR NOT DETAILS ARE REFERENCED AT EACH LOCATION. NOTIFY ENGINEER OF CONFLICTS REGARDING APPLICABILITY OF B. EXTERIOR SLABS: LIGHT FLEXIBLE BRISTLE BROOM FINISH "TYPICAL DETAILS". REINFORCING STEEL: F. DO NOT LOAD THE SLAB ON GRADE OR SUPPORTED SLAB WITH ERECTION CRANES OR ERECTION EQUIPMENT. THE SLABS HAVE NOT BEEN DESIGNED FOR CRANE LOADS AND 1. PROVIDE DETAILING, FABRICATION, AND INSTALLATION OF REINFORCING AND ACCESSORIES WILL REQUIRE AN INCREASE IN THICKNESS AND/OR REINFORCEMENT. OBTAIN A/E IN ACCORDANCE WITH ACI 315 AND ACI 318. APPROVAL ON PROPOSED CRANE SUPPORT PLAN FOR SLABS PRIOR TO COMMENCING WORK. 2 PROVIDE NEW BILLET STEEL REINFORCING BARS IN ACCORDANCE WITH ASTM A 615, G. DO NOT STORE OR STACK CONSTRUCTION MATERIALS ON POURED OR ERECTED GRADE 60 DEFORMED. FLOORS/ROOFS IN EXCESS OF 80 PERCENT OF LIVE LOAD. GENERAL CONTRACTOR WILL 3. COORDINATE PLACEMENT OF CAST -IN -PLACE EMBEDS AND ANCHOR RODS. SET ANCHOR ENSURE THAT ALL SUB -CONTRACTORS ARE INFORMED OF LOADING RESTRICTIONS. RODS WITH A TEMPLATE. SECURELY ATTACH EMBED ITEMS TO FORMWORK OR REINFORCING. AVOID IMPACT WHEN PLACING MATERIALS ON POURED OR ERECTED FLOORS OR ROOF. H. THE CONTRACT STRUCTURAL DOCUMENTS REPRESENT THE FINISHED STRUCTURE. THE 4. PROVIDE CLASS "B" REINFORCEMENT SPLICES FOR CONTINUOUS REINFORCEMENT. PROVIDE CONTRACTOR IS RESPONSIBLE FOR THE MEANS AND METHODS OF CONSTRUCTION. STANDARD 90-DEGREE HOOKS IN ACCORDANCE WITH ACI 318, UNLESS OTHERWISE NOTED. PROVIDE ALL MEASURES REQUIRED TO PROTECT THE STRUCTURE, WORKMEN, AND OTHER PERSONS DURING CONSTRUCTION; INCLUDING BRACING, SHORING FOR CONSTRUCTION 5. MAINTAIN THE FOLLOWING CONCRETE COVERAGE FOR REINFORCING STEEL UNLESS OTHERWISE - EQUIPMENT, SHORING FOR THE BUILDING, FORMS AND SCAFFOLDING, SHORING OF NOTED: RETAINING WALLS AND OTHER TEMPORARY SUPPORTS AS REQUIRED. COMPLY WITH A. CONCRETE CAST AGAINST EARTH: 3 INCHES APPLICABLE REQUIREMENTS OF OSHA AND OTHER GOVERNING BODIES HAVING B. CONCRETE EXPOSED TO WEATHER JURISDICTION AT THE SITE. NO. 6 AND LARGER; 2 INCHES NO. 5 AND SMALLER: 1 112 INCHES I. PRINCIPAL OPENINGS THROUGH THE FRAMING ARE SHOWN ON DRAWINGS. EXAMINE THE C. CONCRETE NOT EXPOSED TO WEATHER OR IN CONTACT WITH THE GROUND: ARCHITECTURAL AND MECHANICAL DRAWINGS FOR THE REQUIRED OPENINGS AND PROVIDE SLABS AND WALLS FOR REQUIRED OPENINGS WHETHER SHOWN ON THE STRUCTURAL DRAWINGS OR NOT, NO. 14 AND NO. 18: 1 1/2 INCHES VERIFY SIZE AND LOCATION OF OPENINGS WITH THE MECHANICAL CONTRACTOR. NO. 11 AND SMALLER: 3/4 INCHES DEVIATIONS FROM THE OPENINGS SHOWN ON THE STRUCTURAL DRAWINGS MUST BE APPROVED PRIOR TO IMPLEMENTING THE CHANGES. 6. DO NOT WELD OR BEND REINFORCEMENT IN THE FIELD UNLESS SPECIFICALLY SHOWN OR APPROVED BY STRUCTURAL ENGINEER. J. LOADINGS FOR MECHANICAL EQUIPMENT ARE BASED ON THE UNITS SHOWN ON THE MECHANICAL DRAWINGS. ANY CHANGES IN TYPE, SIZE, OR NUMBER OF PIECES OF 7. WHEN SPECIFICALLY APPROVED, PROVIDE WELDED REINFORCEMENT IN ACCORDANCE WITH EQUIPMENT SHALL BE REPORTED TO THE ARCHITECT FOR VERIFICATION OF THE ASTM A 706 GRADE 60. USE LOW HYDROGEN ELECTRODES FOR WELDING OF REINFORCEMENT ADEQUACY OF SUPPORTING MEMBERS PRIOR TO THE PLACEMENT OF SUCH EQUIPMENT. IN CONFORMANCE WITH "RECOMMENDED PRACTICES FOR WELDING REINFORCING STEEL", AMERICAN WELDING SOCIETY, AWS D12.1 . PROVIDE ASTM GRADE 40 REINFORCING BARS K. SEE ARCHITECTURAL DRAWINGS FOR ELEVATIONS NOT SHOWN AND FOR EXACT LOCATIONS WHERE DETAILED BARS ARE TO BE WELDED TO A STEEL SECTION. OF ALL SLAB DEPRESSIONS. THE CONTRACTOR SHALL COMPARE THE STRUCTURAL SECTIONS WITH ARCHITECTURAL SECTIONS AND REPORT ANY DISCREPANCY TO THE 8. WHERE REQUIRED, PROVIDE DOWELS TO MATCH SIZE AND SPACING OF MAIN REINFORCING. ARCHITECT PRIOR TO FABRICATING OR INSTALLING STRUCTURAL MEMBERS. 9. PROVIDE CONTINUOUS HORIZONTAL WALL REINFORCEMENT WITH 90-DEGREE BENDS AND EXTENSIONS AT CORNERS AND INTERSECTIONS AS SHOWN ON TYPICAL BAR PLACING DETAILS. 10. WHEN SHOWN ON DRAWINGS PROVIDE FIBRILLATED POLYPROPYLENE FIBERS ENGINEERED AND DESIGNED FOR USE IN CONCRETE COMPLYING WITH ASTM C1116, TYPE 111, 1/2 TO 1 1/2 INCHES LONG. MASONRY: 1. REINFORCED MASONRY WORK AND MATERIALS TO BE IN ACCORDANCE WITH THE BUILDING CODE REQUIREMENTS FOR MASONRY STRUCTURES: ACI 530/ASCE 5/TMS 402.. 2. REINFORCED MASONRY TO CONFORM TO THE SPECIFICATIONS FOR MASONRY STRUCTURES ACI 530.1/ASCE 6/TMS 602 (WITH THE EXCEPTIONS NOTED IN JOB SPECIFICATIONS. 3. PROVIDE CONCRETE MASONRY UNITS (CMU) OF NORMAL WEIGHT (125 PCF MINIMUM), GRADE N, TYPE I OR II, CONFORMING TO LATEST EDITION OF ASTM C 90. LAY UNITS IN RUNNING BOND UNLESS OTHERWISE NOTED. 4. PROVIDE MASONRY ASSEMBLAGES WITH MINIMUM PRISM STRENGTH (fm) OF 1,500 PSI, TESTED IN ACCORDANCE WITH ASTM C 140. 5. PROVIDE CONCRETE MASONRY UNITS IN ACCORDANCE ASTM C 426 LIMITS FOR DRYING SHRINKAGE OF CONCRETE BLOCKS, 6. PROVIDE VERTICAL REINFORCEMENT IN CMU WALLS AS SHOWN IN DRAWINGS. FILL THE REINFORCED CELLS SOLID WITH GROUT. MAXIMUM HEIGHT OF GROUT POURS TO BE AS PER THE SPECIFICATION FOR MASONRY STRUCTURES TABLE NO. 7. UNTIL WALL IS PERMANENTLY BRACED BY ROOF. 7. LAY HOLLOW UNITS WITH FULL MORTAR COVERAGE ON HORIZONTAL AND VERTICAL FACE SHELLS. PROVIDE FULL MORTAR COVERAGE FOR WEBS WHEN ADJACENT TO GROUTED CELLS. 8, ALIGN VERTICAL CELLS TO BE FILLED WITH GROUT TO PROVIDE CONTINUOUS UNOBSTRUCTED VERTICAL CELLS. REMOVE OVERHANGING MORTAR OR OTHER OBSTRUCTION AND DEBRIS FROM THE INSIDES OF CELL WALLS. PROVIDE GROUT WITH 8 INCH SLUMP AND CONSOLIDATE BY MEANS OF HAND TAMPING TO ENSURE COMPLETE FILLING OF CELLS. 9. INSTALL ANCHORS, ACCESSORIES, AND OTHER ITEMS TO BE BUILT IN AS WORK PROGRESSES. 10. PERFORM CUTTING AND FITTING OF MASONRY WITH MASONRY SAWS PROVIDING CUT FINISHED UNITS. 11. CELLS AT OR BELOW FINISHED GRADE ARE TO BE GROUTED SOLID. 12. WHEN A FOUNDATION DOWEL DOES NOT LINE UP WITH A VERTICAL CORE, DO NOT SLOPE DOWEL MORE THAN ONE HORIZONTAL TO SIX VERTICAL, 13. WALL SHALL RECEIVE TEMPORARY BRACING. TEMPORARY BRACING SHALL NOT BE REMOVED UNTIL WALL IS PERMANENTLY BRACED BY ROOF. 14. SPECIAL INSPECTION IS REQUIRED AS FOLLOWS: A. DURING PREPARATION OF REQUIRED PRISMS OR TEST SPECIMENS. B. DURING THE LAYING OF MASONRY UNITS. C. DURING PLACEMENT OF REINFORCING STEEL. D. FOR GROUT SPACES PRIOR TO CLOSING OF CLEANOUTS AND GROUTING. E. DURING ALL GROUTING OPERATIONS. FORWARD INSPECTION RESULTS TO THE ENGINEER OF RECORD. 15. GROUT FILL CORES SHALL CONFORM TO ASTM C478 WITH A MINIMUM COMPRESSIVE STRENGTH OF 2500 PSI IN 28 DAYS. 16. MORTAR SHALL COMFORM TO ASTM C270 A. MASONRY BELOW GRADE: TYPE M MORTAR B. EXTERIOR ABOVE GRADE MASONRY: TYPE S MORTAR 17. GALVANIZED HORIZONTAL REINFORCEMENT SHALL HAVE W1.7 (9 GAGE) SIDE AND CROSS RODS SPACED 16" ON CENTER. LAP REINFORCEMENT 7". STRUCTURAL STEEL: 1. DESIGN, DETAIL AND ERECT STRUCTURAL STEEL ELEMENTS IN ACCORDANCE WITH THE FOLLOWING: A. AISC SPECIFICATION FOR THE DESIGN, FABRICATION, AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS. B. AISC MANUAL OF STEEL CONSTRUCTION, ALLOWABLE STRENGTH DESIGN. C. AISC CODE OF STANDARD PRACTICE FOR STEEL BUILDINGS AND BRIDGES., D. AWS STRUCTURAL WELDING CODE, D1.1 . 2. PROVIDE STRUCTURAL STEEL OF THE FOLLOWING ASTM DESIGNATIONS UNLESS OTHERWISE NOTED: A. STRUCTURAL STEEL WIDE FLANGE SHAPES: ASTM A 992 B. EDGE ANGLES, BENT PLATES, HANGERS AND BRACES: ASTM A 36 C. STRUCTURAL PIPE: ASTM A 53, GRADE B, TYPE E OR S D. HOLLOW STRUCTURAL SHAPES: ASTM A 500, GRADE B E. BASE PLATES AND MISCELLANEOUS STEEL PLATES: ASTM A 36 F. ANCHOR RODS: ASTM F 1554, GRADE 36 3. CONNECTION MATERIALS: A. BEAM -COLUMN STIFFENER PLATES AND DOUBLER PLATES TO MATCH THE GRADE STEEL OF STRUCTURAL ELEMENT B. HIGH STRENGTH BOLTS (SLIP CRITICAL JOINTS FOR ALL BRACES WHERE SPECIFIED): ASTM A 325 C. HARDENED STEEL WASHERS: ASTM F 436 4. WELD MINIMUM SIZE AND STRENGTH: A. PROVIDE MINIMUM SIZE OF FILLET WELDS AS SPECIFIED IN TABLE J2.4 OF THE AISC MANUAL. B. PROVIDE MINIMUM EFFECTIVE THROAT THICKNESS OF PARTIAL PENETRATION GROOVE WELDS AS SPECIFIED IN TABLE J2.3 OF THE AISC MANUAL. C. DEVELOP THE FULL TENSILE STRENGTH OF THE MEMBER ELEMENT JOINED ON ALL SHOP AND FIELD WELDS UNLESS OTHERWISE NOTED ON THE DRAWINGS. D. WHERE CONNECTIONS ARE NOTED ON DRAWINGS AS MOMENT CONNECTIONS, PROVIDE WELDS TO DEVELOP FULL FLEXURAL CAPACITY OF THE LESSER MEMBER. E. PROVIDE ELECTRODES FOR FIELD OR SHOP WELDING THAT CONFORM TO ASTM A 233 (CLASS 70). F. ALL WELDS ARE CONTINUOUS FOR THE FULL LENGTH OF THE CONNECTION UNLESS OTHERWISE NOTED ON DRAWINGS. 5. PROVIDE MINIMUM OF TWO BOLTS PER CONNECTION. PROVIDE MINIMUM BOLT DIAMETER OF 3/4 INCH. 6. PROVIDE BOLTS, NUTS AND WASHERS THAT ARE HOT DIP GALVANIZED ACCORDING TO ASTM A 153, CLASS C WHEN USED TO CONNECT STEEL ELEMENTS THAT ARE HOT DIP GALVANIZED AFTER FABRICATION. 7. PROVIDE SIMPLE SHEAR CONNECTIONS FOR STEEL CONNECTIONS NOT SPECIFIED OTHERWISE UTILIZING HIGH STRENGTH BEARING BOLTS IN SINGLE OR DOUBLE SHEAR. PROVIDE DOUBLE ANGLE OR SINGLE PLATE SHEAR TAB BOLTED CONNECTIONS. A. UNLESS LARGER REACTION IS SHOWN ON DRAWINGS, PROVIDE MINIMUM DESIGN FORCES AS FOLLOWS: 1. NONCOMPOSITE BEAMS: BEAM -TO -BEAM OR BEAM -TO -COLUMN CONNECTION TO DEVELOP THE REACTION OF CONNECTED BEAM. OBTAIN END REACTION FROM ALLOWABLE UNIFORM LOAD TABLES IN PART 2 OF THE AISC MANUAL OF STEEL CONSTRUCTION. 8. ADD TO REACTIONS LISTED ABOVE, LOADS OR REACTIONS OF MEMBERS SUPPORTED BY BEAM WITHIN THREE FEET OF BEAM END AND VERTICAL COMPONENTS OF FORCES IN BRACE MEMBERS FRAMING INTO BEAM. 9. BRACE CONNECTIONS SHALL BE IN ACCORDANCE WITH THE DETAILS SHOWN ON THE DRAWINGS. ANGLE SIZES, PLATE SIZES, AND SIZE AND LENGTHS OF WELDS SHALL BE DESIGNED IN ACCORDANCE WITH THE FOLLOWING: A. DESIGN CONNECTIONS OF DIAGONAL MEMBERS TO DEVELOP THE LOADS SHOWN ON THE BRACE DETAILS. B. WHERE FORCES ARE NOT INDICATED ON THE DETAILS, DESIGN CONNECTIONS OF DIAGONAL MEMBERS TO DEVELOP THE FULL TENSILE CAPACITY OF THE DIAGONAL MEMBER. C. SIZE GUSSET PLATES AND ALL WELDS TO RESIST THE FORCE OF THE DIAGONAL MEMBERS. PLATES AND WELDS SHALL BE SIZED FOR TENSIONS SHEARS AND MOMENTS CAUSED BY CONCENTRIC AND ECCENTRIC FORCES. D. ALL BRACE CONNECTIONS SHALL USE WELDS OR FULLY TENSIONED A325 CLASS A SLIP CRITICAL BOLTS. STRUCTURAL STEEL CONT: 10. STEEL FABRICATION: A. FABRICATE AND ASSEMBLE STRUCTURAL MEMBERS/ASSEMBLIES IN SHOP TO GREATEST EXTENT POSSIBLE. B. CAMBER OF STRUCTURAL STEEL MEMBERS IS INDICATED ON THE DRAWINGS.. WHERE POSSIBLE, CAMBER OF BEAMS TO BE APPLIED BY COLD BEND PROCESS. CAMBER INDICATED ON DRAWINGS IS INTENDED TO BE FINAL CAMBER AT TIME OF ERECTION, AND WITHIN A TOLERANCE OF MINUS ZERO TO PLUS ONE -EIGHTH INCH FOR EACH TEN FEET OF MEMBER LENGTH. C. SPLICING OF STRUCTURAL STEEL MEMBERS IS PROHIBITED WITHOUT PRIOR APPROVAL BY THE A/E. D. BE RESPONSIBLE FOR ALL ERRORS OF DETAILING ON THE SHOP DRAWINGS, ERRORS IN FABRICATION, AND THE CORRECT FITTING OF STRUCTURAL STEEL MEMBERS. E. CONFORM TO THE AISC CODE OF STANDARD PRACTICE, FOR ERECTION TOLERANCES. FIELD MODIFICATION TO STRUCTURAL STEEL IS PROHIBITED WITHOUT PRIOR APPROVAL BY THE A/E. F. CLEAN STEEL OF RUST, LOOSE MILL SCALE AND OTHER FOREIGN MATERIALS WHERE REQUIRED FOR FABRICATION, FITTING UP, OR WELDING. G. DO NOT CUT STRUCTURAL STEEL MEMBERS FOR THE WORK OF OTHER TRADES WITHOUT PRIOR REVIEW AND APPROVAL OF THE A/E. 11. HOT DIP GALVANIZE AFTER FABRICATION ALL STRUCTURAL STEEL AND THEIR CONNECTIONS PERMANENTLY EXPOSED TO THE OUTSIDE. ITEMS INCLUDED BUT NOT LIMITED TO: A. SHELF ANGLES. B. PARAPET WALL SUPPORTING MEMBERS C. EMBEDDED PLATES IN CONCRETE D. BUILDING CLADDING SUPPORT STEEL E. EXAMINE THE ARCHITECTURAL AND STRUCTURAL DRAWINGS FOR OTHER ITEMS THAT REQUIRE HOT DIPPED GALVANIZATION. 12. PROVIDE GROUT FOR BASE PLATES THAT IS NON -SHRINK, NON-METALLIC GROUT WITH MINIMUM 28 DAY COMPRESSIVE STRENGTH OF 6000 PSI. COMPLETE GROUT WORK PRIOR TO PLACING ROOF CONCRETE OF A SINGLE STORY BUILDING OR PRIOR TO PLACING SECOND FLOOR CONCRETE OF A MULTIPLE STORY BUILDING. 13. SUBMIT CALCULATIONS FOR CONNECTION DESIGNS NOT DETAILED ON DRAWINGS. DESIGN CONNECTIONS UNDER SUPERVISION OF REGISTERED PROFESSIONAL ENGINEER, REGISTERED IN THE STATE WHERE PROJECT IS BEING CONSTRUCTED, EMPLOYED BY THE STEEL FABRICATOR. DESIGN CALCULATIONS TO BE SEALED BY FABRICATOR'S REGISTERED PROFESSIONAL ENGINEER. SHOP DRAWINGS SUBMITTED WITHOUT COMPLETE DESIGN CALCULATIONS WILL NOT BE REVIEWED. WHERE PREDESIGNED CONNECTIONS ARE TAKEN DIRECTLY FROM TABLES IN AISC MANUAL, CALCULATIONS NEED NOT BE SUBMITTED PROVIDED JOB DESIGN CONDITIONS PRECISELY MATCH THOSE ASSUMED IN THE AISC MANUAL. 14. PROVIDE WASHERS FOR ALL CONNECTIONS WITH STANDARD, OVERSIZE AND SHORT -SLOTTED HOLES. FOR LONG -SLOTTED HOLES PROVIDE WASHERS OR A CONTINUOUS BAR OF SUFFICIENT SIZE TO COMPLETELY COVER THE SLOT. PLATE WASHERS OR BARS TO BE MINIMUM OF 5/16 INCH THICK FOR LONG -SLOTTED HOLES. 15. WIDE FLANGE BEAM CONNECTIONS TO TUBE COLUMNS SHALL BE MADE WITH BOLTED SHEAR TAB PLATE TYPE CONNECTIONS UNLESS OTHERWISE NOTED ON PLAN. ONE-SIDED CONNECTIONS SHALL BE DESIGNED AS ECCENTRIC CONNECTIONS. 16.. FURNISH STEEL SHOP DRAWINGS FOR ARCHITECT'S AND STRUCTURAL ENGINEER'S REVIEW PRIOR TO FABRICATION. INCLUDE WELDING PROCEDURES, TESTING PROGRAMS FOR WELDING AND HIGH STRENGTH BOLTING, COATING MATERIAL AND ERECTION SEQUENCE ON SHOP DRAWINGS. 17. MILL STEEL COLUMN ENDS TO FIT FLUSH WITH BASE PLATE, CAP PLATE AND END PLATES. FIELD ASSEMBLY OF THESE STEEL ELEMENTS TO THE COLUMNS IS PROHIBITED.. 18. HEADED STUDS (SHEAR AND ANCHOR) AND DEFORMED ANCHORS: A. PROVIDE HEADED STUDS (SHEAR AND ANCHOR) MADE OF MATERIAL CONFORMING TO ASTM A 108. B. PROVIDE DEFORMED ANCHORS MADE OF MATERIAL CONFORMING TO ASTM A 496. C. WELD STUDS ACCORDING TO MANUFACTURER'S RECOMMENDATIONS. MANUAL ARC (STICK) WELDING OF HEADED STUDS AND/OR DEFORMED ANCHORS IS NOT ALLOWED. 19. PRIOR TO DECK PLACEMENT, VERIFY THAT STEEL BEAMS BEARING ON MASONRY HAVE 8 INCH MINIMUM BEARING AND ARE ANCHORED AS SHOWN ON DRAWINGS. 20. PROVIDE TEMPORARY SHORING OR BRACING DURING CONSTRUCTION PHASE, PRIOR TO COMPLETING CONNECTIONS AND POURING OF FLOOR SLAB. TEMPORARY CONSTRUCTION BRACING OF THE STRUCTURAL STEEL FRAME IS THE RESPONSIBILITY OF THE CONTRACTOR AND SHALL REMAIN IN PLACE UNTIL AFTER THE PERMANENT BRACING SYSTEM HAS BEEN COMPLETED. 21. CLEAN STEEL TO BE PAINTED IN ACCORDANCE WITH STEEL STRUCTURES PAINTING COUNCIL POWER TOOL CLEANED SSPC-SP3. 22. ALL STRUCTURAL STEEL SHALL BE SHOP PRIMED WHITE OR LIGHT GREY TO PROVIDE DRY FILM THICKNESS NOT LESS THAN 1.0 MIL: ASPHALTIC PAINTS ARE NOT ACCEPTABLE. LIGHT GAGE STEEL: 1. PROVIDE ALL STUDS AND/OR JOISTS AND ACCESSORIES OF THE TYPE, SIZE, GAGE AND SPACING SHOWN ON THE DRAWINGS. 2. DESIGN ALL STRUCTURAL MEMBERS IN ACCORDANCE WITH AMERICAN IRON AND STEEL • INSTITUTE (AISI) "NORTH AMERICAN SPECIFICATION FOR THE DESIGN OF COLD FORMED STEEL MEMBERS" 3. FORM ALL FRAMING MEMBERS FROM CORROSION RESISTANT STEEL, CORRESPONDING TO THE REQUIREMENTS OF ASTM A653 AND THE FOLLOWING STRENGTH REQUIREMENTS: FRAMING MEMBER GAGE MINIMUM YIELD STUDS, JOISTS 20,18 33 KSI STUDS, JOISTS 10,1 2,14,16 50 KSI RUNNERS, SOLID BLOCKING 20 33 KSI 4. PLACE ALL COLD -FORMED STEEL STUD WALL BRIDGING HORIZONTALLY WITH A MAXIMUM VERTICAL SPACING OF FOUR FEET UNLESS OTHERWISE NOTED. AS AN OPTION, CONTINUOUS COLD -FORMED CHANNELS MAY BE POSITIONED THROUGH THE STUD PUNCH OUTS AS BRIDGING PROVIDED THE CHANNEL IS PROPERLY FASTENED TO EACH STUD. 5. INSTALL AXIALLY LOADED STUDS IN A MANNER WHICH WILL ASSURE THAT THEIR ENDS ARE POSITIONED AGAINST THE INSIDE OF RUNNER WEB PRIOR TO FASTENING. 6. FASTEN COMPONENTS WITH SELF -DRILLING SCREWS OR WELDING. PROVIDE SCREWS OF SUFFICIENT SIZE TO INSURE THE STRENGTH OF THE CONNECTION. WIRE TYING OF COMPONENTS IS NOT PERMITTED. TOUCH UP ALL WELDS WITH A ZINC -RICH PAINT. • LIGHT GAGE STEEL CONT: 7. WELDING OF COLD -FORMED STUDS MAY BE PERFORMED USING A MINIMUM ONE -EIGHTH INCH AWS TYPE 6013 WELDING ROD. 8. SECURELY ANCHOR RUNNERS TO THE SUPPORTING STRUCTURE. PROVIDE COMPLETE, UNIFORM, AND LEVEL BEARING SUPPORT FOR THE BOTTOM RUNNER. 9. SECURELY ANCHOR ABUTTING LENGTHS OF RUNNER TO A COMMON STRUCTURAL ELEMENT BUTT -WELDED OR SPLICED. 10. PLUMB, ALIGN, AND SECURELY ATTACH STUDS TO THE FLANGES OF BOTH UPPER AND LOWER RUNNERS. SPLICES IN STUDS ARE NOT PERMITTED. 11. PROVIDE HEADERS AND SUPPORTING STUDS FOR FRAMING OF WALL OPENINGS. 12. STABILITY BRIDGING SHALL BE INSTALLED AT A MAXIMUM 4'-0" O.C. FOR SUSPENDED SOFFITS UNLESS OTHERWISE NOTED. 13. DESIGN OF METAL STUD FRAMING SHOWN IS BASED ON CEE TYPE (1 5/8" FLANGE) STUDS BY DALE INDUSTRIES. 14. SHOP DRAWINGS AND CALCULATIONS FOR COLD FORMED METAL FRAMING TO BE SIGNED AND SEALED BY A PROFESSIONAL ENGINEER REGISTERED IN THE STATE WHERE THE PROJECT IS LOCATED. PRE-ENGINEERED METAL BUILDING (PEMB) A. PRE-ENGINEERED METAL BUILDING MANUFACTURER SHALL DESIGN AND FURNISH ALL FRAMING TYPICAL UNLESS SPECIFICALY STATED ON THE STRUCTURAL DRAWINGS OTHERWISE. B. PRE-ENGINEERED METAL BUILDING MANUFACTURER SHALL PROVIDE SHOP DRAWINGS IN A TIMELY MANNER PRIOR TO FABRICATION TO VERIFY LOADS USED FOR FOUNDATION DESIGN. C. FOUNDATION DESIGN AS SHOWN ON STRUCTURAL DRAWINGS IS PRELIMINARY ONLY. ITEM B. SHOULD BE SUBMITTED FOR FINAL DESIGN. D. PRE-ENGINEERED METAL BUILDING MANUFACTURER SHALL DESIGN & SUPPLY ENGINEERING FOR ROOF OPENINGS, ROOF TOP UNITS, AND ANY HUNG LOADS WITH OTHER TRADES. THE SCOPE OF THE PRE -MANUFACTURED METAL BUILDING STRUCTURE SHALL INCLUDE THE DESIGN, ENGINEERING, FABRICATION, DELIVERY, AND ERECTION OF THE COMPLETE STRUCTURAL STEEL FRAMING AND EXTERIOR SKIN PACKAGE. THE METAL BUILDING MANUFACTURER SHALL BE CERTIFIED BY AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC) METAL BUILDING CERTIFICATION PROGRAM PRE-ENGINEERED METAL BUILDING COMPANY CONTACTS PHONE # 4537568- VP BUILDINGS DAVID ENGLISH 901- PRE-ENGINEERED METAL BUILDING DEnglish@vp.com STAR BUILDING SYSTEMS _JE_FF.H RN 866664- 8899 PRE-ENGINEERED METAL BUILDING NUCOR BUILDING SYSTEMS BOB BARRY 315-622-4440 1 PRE-ENGINEERED METAL BUILDING BIG BEE STEEL BUILDINGS, INC. CHIEF BUILDINGS CONSULTANT: SEAL: GARY MAEDA, PE 68724 � Y °s\ C�� e t N No. 68724 ' Wzi THIS DRAWING SHALL NOT BE USED FOR CONSTRUCTION PURPOSES UNTIL THE SEAL AND SIGNATURE OF THE RESPONSIBLE REGISTRANT APPEARS ON THE DRAWING, AND PROPER PERMIT FORMS AND RELATED FEES ARE TRANSMITTED BY THE OWNER, OWNER'S AGENT OR CONTRACTOR TO THE AUTHORITY HAVING JURISDICTION. DATE ISSUED FOR REV 09/27/2018 PEMB COORDINATION 1 1/27/201 8 OWNER REVIEW 1 2/1 8/201 8 PERMIT SUBMITTAL Project Manager Drawn L. LONG D. GRIFFIN Project leader Checked L. LONG Date Dept Mgr Approval 08/07/2018 G MAEDA Client PALMETTO ZEPHYRHILLS-20th St, LLC P,O. BOX 1615 THOMASVILLE, GA 31792 Office: (229) 226-0682 Contact: John Tate Project DOLLAR GENERAL 38965 CR 54 Zephyrhills, FL 33542 (City of Zephyrhills) Store #: 20360 Drawing Title STRUCTURAL GENERAL NOTES DO NOT SCALE DRAWING Project No, Drawing No. JCDT.18.0233 S1 1' I iI i 9. OR r. le i. 1414, nr'. r ,... I , 11i 11, 1111i 1 1 1 111 1 1 1 1II - on • POST AND BEAM ALONG END WALL 4 S3 T-8" 7'-8" I � FT4 T - 0 N CV FT4 C m d 1q m S3 m cn LINEQ6 a b0 O N Z m 11 I S3 > 0 N U) 5 26'-0" 26'-0" 2 S3 . FT6 FT8 F L J U) U) A = 9 � S3 4" 4'-8" 5'-6" 4 4 S3 S3 LINE D 6 S3 SJ SJ SJ SJ SJ 2 3 26'-0" _ 1 VERT WALL BRACING THIS BAY BY PEMB ROOF BRACING THIS BAY BY PEMB FT8 F L -1 U) I Cl) 14 2 6'-0" 8" CMU SILL WALL TO -0" 1 9 N N V-8" x V-8" x 9 1/2" -' -- - FT8 DEEP COL POCKET FT8 TYP @ INT FT4 I I I 1 FF ELEV 0'-0" 1 - �0� 7 c B 6 S2 I �. s3 LINE 1Q m 1 ..... �� w T/FTG 0'-0" 0. TYP INT } U) � � 11 S3 m Ln 1 TYP I o CD `° S3 � Z o 8" CMU SILL N U ti WALL TO 4'-0" AFF FROM m GRID LINE J [ TO OD of FT4 > 8" CMU TO 10'-8" AFF REF 6/S4 j! 3 0 r T, T,— _ S3 6 - � OP 54 I o - ......... -'-' / HA Dom-/ N o, f # 8 HAIRPIN TYP --- 1 FC �� @ EACH PEMB f 52 6° I COLUMN I 6 I �`1/'O 2 1 FT6 I FT6 FT4 - - I - - T/FTG1 1 t 1 0 ._�_ _� �8" CMU SILL � �_�_�_�_�F.l�_�_ _ j WALL TO 5 5 4'-0" AFF FROM S3 -'-'-- \,—,/ GRID LINE 11 S3 8" CMU TO SIM O S3 �� 3 10'-8" AFF V-8„ 2 S3 REF 6/S4 �1 CL COL 10'-10%Z" - POST AND BEAM 8- ALONG END WALL 26'-0" 26'-0" 26'-0" 26'-0" 26'-8" VERT WALL BRACING THIS BAY BY PEMB 130'-8" , 8" CMU SILL WALL 'u�4X4k1f4 2 S4 CONT C8x11.5 (10'-10") SOFFIT FRAMING yS 6 (BY PEMB) k� 1/ 54 8" CMU ..._ 1 SILL WALL CONT C8x11.5 S4 (10'-10") 1 2 ENTRANCE FRAMING PLAN L� 5 4 NORTH FOUNDATION PLAN HEAVY HEX NUT W/ OVERSIZED HEAVY PLATE WASHER O 1 1/2" NOW U SHRINK GROUT 0 °-_ _T/ CONC AT F1554 POCKET RE: S3 GR36 ROD O OVERSIrs Q RE: SCHED O Q p O u— U. Q HEAVY HEX °D � CD NUT W/ � C,ZED WASHER TACK WELD - FOR ANCHOR ROD SIZE, TO ROD QUANTITY, AND LOCATIONS RE: PEMB DRAWINGS 3 TYP ANCHOR ROD DETAIL Scale. 1 — 1 0 FOUNDATION DESIGN LOAD P GRAVITY = +8K P UPLIFT = 4K H LATERAL = +2K 2'-8"x2'-8" C W/ (8) #5 VE AND #4@6" 2 1 CONCRETE PIER BELOW 8" CMU COLUMN COVER REINF W/ #5 EA CORNER AND MASONRY JOINT REINF @ 16" OC PROVIDE CMU BOND BEAM REINF W/ (2) #4 CONT ON ALL FOUR SIDES AT TOP OF COL COVER AT EL 10'-8" EXTERIOR FTG AND COLUMN Scale: 1/2" = 1'-0" oo EDGE OF SLAB — 0 m FOOTING SCHEDULE FOOTING FOOTING SIZE FOOTING REINFORCEMENT NOTES MARK T W X L BOTTOM TOP FT2,0 2'-0" 2'-0" CONT. 2- #6 CONT. 2- #6 CONT. FT4 2',0" 4'-0" X 4'-0" 546 EA. WAY 546 EA. WAY FT6 2'-0" 6'-0" X 6'-0" 746 EA. WAY 746 EA. WAY FT8 2'-4" 8'-0" X 8'-0" 1146 EA. WAY 1146 EA. WAY FOUNDATION NOTES: 1. ALL DIMENSIONS SHALL BE COORDINATED WITH ARCHITECTURAL DRAWINGS. 2. SJ DESIGNATES SHRINKAGE CONTROL JOINT OR CONSTRUCTION JOINT. RE: DETAIL 1/S3 3. CONTRACTOR TO COORDINATE ALL CONDUIT AND PLUMBING STUB -UP LOCATIONS WITH ELECTRICAL AND PLUMBING PLANS. 4. FTx INDICATES FOOTING MARK- RE: FOOTING SCHEDULE. 5. SIDEWALKS ARE NOT SHOWN ON STRUCTURAL PLANS OR DETAILS. RE: ARCH AND OR CIVIL DRAWINGS FOR TYPICAL SIDEWALK INFO. 6. T/FTG INDICATES TOP OF FOOTING ELEVATION 7. TOP OF BEAM DESIGNATED (XX'-X") ABOVE FINISHED FLOOR 8. RE: SHT S1 FOR GENERAL NOTES KEY NOTES: O 4" CONCRETE SLAB WITH 6x6-W2.9xW2.9 WWF ABOVE VAPOR RETRADER OVER 6" AGGREGATE BASEOR COMPACTED GRANULAR FILL OVER PREPARED SUBGRADE. RE: 1/S3 O2 RE: ARCH FOR DOOR OPENING LOCATION. IBC MASONRY SPLICE TABLE REINFORCING SIZE 8" MASONRY 1 BAR CENTERED 8" MASONRY 2 BARS IN CELL OR OFFSET BARS #4 15" 26" (2" CLR) #5 23" 40" (2" CLR) #6 43" 74" (2" CLR) END WALL DETAIL Scale: 1" = V-0" FOUNDATION DESIGN LOAD PGRAVITY = 24K PUPLIFT = -19K BASE PL POCKET RE: PLAN 9 1/2" DEEP COL POCKET —, PRE-ENGINEERED METAL BUILDING (PEMB) A. PRE-ENGINEERED METAL BUILDING MANUFACTURER SHALL DESIGN AND FURNISH ALL FRAMING UNLESS SPECIFICALY STATED ON THE STRUCTURAL DRAWINGS OTHERWISE. B. PRE-ENGINEERED METAL BUILDING MANUFACTURER SHALL DESIGN & SUPPLY ENGINEERING FOR ROOF OPENINGS, ROOF TOP UNITS, AND ANY HUNG LOADS WITH OTHER TRADES. THE SCOPE OF THE PRE -MANUFACTURED METAL BUILDING STRUCTURE SHALL INCLUDE THE DESIGN, ENGINEERING, FABRICATION, DELIVERY, AND ERECTION OF THE COMPLETE STRUCTURAL STEEL FRAMING AND EXTERIOR SKIN PACKAGE. THE METAL BUILDING MANUFACTURER SHALL BE CERTIFIED BY AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC) METAL BUILDING CERTIFICATION PROGRAM COL, BASE PL AND ANCHOR BOLTS BY PERM ! 1 1/2" NON -SHRINK I GROUT MONOLITHIC FOOTING AND SLAB ON GRADE FIN FL ELEV 0'-0" �1 3" COVER RE: PLAN RE: PLAN TYP RE: FTG SCHEDULE FOR REINF T&B 6 INTERIOR FTG AT PEMB COLUMN Scale. 1/2 — 1 0 CONSULTANT: SEAL: GARY MAEDA, PE 68724 Et��ttzt ,, No, 6&724 '. o OR THIS DRAWING SHALL NOT BE USED FOR CONSTRUCTION PURPOSES UNTIL THE SEAL AND SIGNATURE OF THE RESPONSIBLE REGISTRANT APPEARS ON THE DRAWING, AND PROPER PERMIT FORMS AND RELATED FEES ARE TRANSMITTED BY THE OWNER, OWNER'S AGENT OR CONTRACTOR TO THE AUTHORITY HAVING JURISDICTION. DATE ISSUED FOR REV 09/27/2018 PEMB COORDINATION 1 1 /27/2018 OWNER REVIEW 12/18/2018 PERMIT SUBMITTAL Project Manager Drawn L. LONG D. GRIFFIN Project Leader Checked L. LONG Date Dept Mgr Approval 08/07/2018 G MAEDA Client PALMETTO ZEPHYRHILLS-20th St, LLC P.O. BOX 1615 THOMASVILLE, GA 31 792 Office: (229) 226-0682 Contact: John Tate Project DOLLAR GENERAL 38965 CR 54 Zephyrhills, FL 33542 (City of Zephyrhills) Store #: 20360 Drawing Title FOUNDA11ON PLAN AND SCHEDULES DO NOT SCALE DRAWING Project No. Drawing No. JCDT.18.0233 82 T/ STEEL ELEV 4'-0" 8" CMU WALL REINF W/ #5 @ 48" OC CENTERED GROUTED SOLID_ SEE CIVIL DWGS FOR FINISH GRADE OR ASPHALT PAVING ELEVATION —� 0 N "Poll 1 1/2" DEEP COL POCKET 8" CMU SILL WALL FOUNDATION 1/2" DIA x 2'-0" SMOOTH BAR DESIGN LOAD 1 AT 12" OC AT ALL DOOR GRAVITY = +1I2K LOCATIONS UPLIFT = -12K LATERAL = ±5K 4" CONC SLAB WITH JOINTS SHALL BE FILLED TYP SHRINKAGE JOINT (SJ) FLUSH WITH JOINT FILLER TYP CONST JOINT #4@12" OC EW OVER 1/8"x t/4 SAWCUT OR 71"x EDGE OF 4" AGGREGATE BASE {/ " IF NEEDED I SLAB $ PREMOLDED INSERT 4 REF ARCH FOR SLAB ELEV FT4 _J TURN DOWN SLAB REQUIRED I/3 1 1/2" DEEP EGRESS DOOR- ._, COL POCKET ^ CMU t RE: ARCH 3/8" EXP JT m 0�' 0.<D� co 3/4 CHAMFER ^ I THRESHOLD : 1 Nl .�: l SEE CIVIL DWGS FOR FINISH RE: ARCH' `o GRADE OR ASPHALT PAVING ? PREPARED VAPOR RETARDER H 4 C I SLAB ON GRADE FIN FL ELEVATION ONLY SLOPESUBGRADE LAP JOINTS MINIMUM 6" AND SEAL WITH ELEV 0'-0" PRESSURE SENSITIVE TAPE. . ,. _ _... AGGREGATE BASE COL BY PEMB 10,> 7>, 0 • • x x . MANUF All^ I 4 OR COMPACTED , � €_ _. �. GRANULAR FILL • I (1 (4) #4 @ 12" TOP EXTEND 3'-0" 8" CMU I BEYOND EA SIDE OF DOOR NOTE: SILL WALL ^ OPENING (BEND AT ENTRY) 1. SAW CUT CONTROL JOINT SHALL BE COMPLETED BETWEEN 4 TO 12 HOURS AFTER 2-0 RE: FTC SCHEDULE RE: PLAN CONCRETE SLAB HAS BEEN PLACED. „ #4 DWL @ 12" OC FOR REINF T & B " #5 CONT T&B 1'-0" 2. VAPOR RETARDER SHALL BE ASTM E 1745, CLASS A WITH A WATER VAPOR TRANSMISSION 3'-0" 1'-0\\ TURNDOWN SLAB ON RATE OF 0.012 PERMS OR LESS AS TESTED BY ASTM E 96, NOT LESS THAN 10 MILS THICK THREE SIDES DOWEL TO BLDG TUNDOWN SLAB SHADED AREA INDICATES PORTION OF COLUMN FOOTING THAT SHALL BE HELD DOWN 0'-8" FROM FINISHED FLOOR (REF DETAIL 2/S3) C8 BY PEMB MANUF W/ 5/8" DIA HILTI HIT HY-270 ADHESIVE ANCHOR @ 48" OC AND 5 5/8" EMBEDMENT INTO GROUTED CORES - CMU BOND BEAM REINF W/ (2)-#4 CONT #4 @ 12" DWLS 2'-0" SLAB ON GRADE FIN FL ELEV V-0„ OIL �1 OL • 1 41 3" COVER (2) #6 CONT TYP T&B 2'-0" TURNDOWN SLAB 1 ALONG END AND SIDE WALL S3 1/2" = V-0" 5 4 FT6 F- - - - ----� � I I I � I I COL BY I-- — d 1 1/2" DEEP PEMB COL POCKET MANUF 0 r l9 . - 61 /� 8" CMU SILL WALL 4" CMU RE: ARCH H 3'-0$' FOUNDATION _. DESIGN LOAD PGRAVITY = +13K PUPLIFT = -11K TYP FOOTING HLATERAL = ±6K 12 ALONG SIDE WALL S3 1/2" = V-0" TYP FOOTING ALONG ENDWALL S3 1/2" = V-0" 1 '-0ll ,1' —0„ COL BY PEMB MANUF FT4 o EDGE OF L I I SLAB d o I ' I cV I L- 1 1/2" DEEP COL POCKET 8" CMU SILL WALL FOUNDATION DESIGN LOAD 2'-0" P GRAVITY = +6K P UPLIFT = -4K H LATERAL = ±1 K FOOTING AT FRONT CORNER S3 '11� FOUNDATION DESIGN LOAD PGRAVITY = +5K PUPLIFT = 4K HLATERAL ±1 K COL BY PEMB MANUF 4" CMU RE: ARCM;---' S3 1/2" = 1 '-0" EDGE OF SLAB — , 4" CMU RE: ARCH A EDGE OF SLAB I 1 112" DEEP — — COL POCKET 3., ` , 3 A. ,. t 5 77 Ajj�� �3�s ,a 3� •; i „, ii333 3 „ „f FOOTINGAT CORNERS 1 SECTION AT ENTRANCE 4 AND EXITS WITH SIDEWALK S3. _. 1/211 = 11-01' 3 2 r--------------� I I � FT6 " " 1 1/2" DEEP 55COL BY COL POCKET PEMB PEMB L_ — N MANUF ^N A - EDGE OF SLAB — 4" CMU RE: ARCH 0 0 N c0 8" CMU I SILL WALL T FOUNDATION DESIGN LOAD 3'-0" H 3'-0,, PGRAVITY = +14K PUPLIFT = -12K TYP FOOTING HLATERAL = ±6K S5ALONG SIDE WALL S3 1/2" = V-0" 5 4 3 2 3'—01, 3'-011 CMU RE: ARCH IH FT6 FOOTINGYP ALONG S3 1 /2" = 1 '-0" �J TYP SLAB ON GRADE S3 1 /2" = V-0" O LL z� U 8" HOLD DOWN FOR 0 0 1 1/4x1J4 EXTERIOR CMU p W STRAP ANCH w 1 1/4"x1/4 STRAP ANCH WITH p H 00 NO SLAB 3" RIGHT ANGLE BENDS EACH O p HOLD DOWN END AT 16" OC VERT EA SIDE GIRT BY PEBM � 0 ^ BELOW PEMB AT COL WEB. COORD VERT =� § 00 COL LOC'N WITH BLOCK COURSING d (WHERE CMU WALL OCCURS AT I COLUMNS). TACK WELD STRAP Oy 3 TO COLUMN z v PLAN A -A 3 00 A I A COL, BASE PL AND p w I MONOLITHIC FOOTING J ANCHOR BOLTS 0 X SEE CIVIL DWGS FOR BY PEBM AND SLAB ON GRADE = w FINISH GRADE OR r ASPHALT PAVING HAIRPIN ANCHOR ELEVATION I HOOKED AROUND OUTSIDE AB COL POCKET I 1 1/2" NON SHRINK CENTERED IN SLAB RE: PLAN GROUT FIN FL e — ,_ �,�..� __.. — — — E 0 -0 ELEV " s� 3" COVER TYP ` 1 TURNDOWN SLAB TURNDOWN SLAB BEYOND RE: 3/S3 & REINF CONT THRU 1l/S3 FTG T&B RE: 3/S3 & 11/S3 RE: FTG SCHEDULE FOR REINF T&B RE: PLAN RE: PLAN NOTE EXTERIOR FTG AT IN SLAB ON GRADE HAIRPIN n c R A o I I l R A K r NOT SHOWN FOT CLARITY S3 1 /2" = 1 '-0" C8 BY PEMB MANUF 1 W/ 5/8" DIA HILTI HIT HY-270 ADHESIVE ANCHOR 8" @ 16" OC AND 5 5/8" EMBEDMENT T/ STEEL ELEV INTO GROUTED CORES 10'^10" T/ WALL ELEV gk CONT C8xl 1.5 W/ 5/8" DIAx HILTI HIT HY-270 ADHESIVE ANCHOR ' J RE: 1/S2 IF CMU BOND BEAM REINF @ 16" OC AND 5 5/8" EMBEDMENT INTO GROUTED CORES E W/ (2)-#4 CONT 8" CMU WALL REINF W/ #5 @ 16" OC CENTERED GROUTED SOLID,: #4 @ 12" DWLS SEE CIVIL DWGS FOR ` 2'-0" FINISH GRADE OR SLAB ON GRADE -, ASPHALT PAVING ELEVATION FIN FL ELEV 0'-0" 0 N 3" COVER TYP II �1 21 011 1 (2) #6 CONT T&B TURNDOWN SLAB 3 AT FRONT WALLS S3 1 /2" = V-0 CONSULTANT: SEAL: GARY MAEDA, PE 68724 .�o No, 68724 STATE OP THIS DRAWING SHALL NOT BE USED FOR CONSTRUCTION PURPOSES UNTIL THE SEAL AND SIGNATURE OF THE RESPONSIBLE REGISTRANT APPEARS ON THE DRAWING, AND PROPER PERMIT FORMS AND RELATED FEES ARE TRANSMITTED BY THE OWNER, OWNER'S AGENT OR CONTRACTOR TO THE AUTHORITY HAVING JURISDICTION. DATE ISSUED FOR REV 09/27/2018 PEMB COORDINATION 1 1/27/2018 OWNER REVIEW 12/18/2018 PERMIT SUBMITTAL Project Manager Drawn L. LONG D. GRIFFIN Project Leader Checked L. LONG Date Dept Mgr Approval 08/07/2018 G MAEDA Client PALMETTO ZEPHYRHILLS-20th St, LLC P.O. BOX 1615 THOMASVILLE, GA 31792 Office: (229) 226-0682 Contact: John Tate Project DOLLAR GENERAL 38965 CR 54 Zephyrhills, FL 33542 (City of Zephyrhills) Store #: 20360 Drawing Title FOUNDATION SECTIONS AND DETAILS DO NOT SCALE DRAWING Project No. Drawing No. JCDT.18.0233 83 TYP m 5 S4 21'-0" u o c+o..o..n in ELEVATION AT STOREFRONT ENTRANCE S4 SCALE: 3/8" = V-0" 3 EMBED PL EP2 HSS8x8 T / STEEL RE: 4/S4 T / CMU WALL ELEV 10'-8" A ('3 DETAIL S4 SCALE: NTS CMU 4'-0" AFF T / STEEL ELEV 8'-2" HSS8x6 #5 @ 16" OC CENTERED IN GROUTED CELL FROM HSS BEAM FOOTING TO T/WALL DOWEL RE: 2/S2 6 DETAIL S4 1 IT = 1 011 PL 7 1/2x3/8x1'-0" LG W/ (2) 3/4"x8" LG HEADED STUD ANCHORS ih o CID 3 3/4" 3 3/4" 7 1 /2" EP1 PL 7 1/2x3/8xl'-0" LG W/ (2) 3/4"x8" 3" LG HEADED STUD ANCHORS M O iY) 3 3/4" 3 3/4" EP2 4 EMBED PLATE DETAIL S4 SCALE: NTS WELD TO BOT OF STL LINTEL TYP FOUNDATI DESIGN LC P GRAVITY PUPLIFT HLATERAL 3 1 /2x3 1 /2x1 /4 ' A x 0-3 I HSS4x4xl, RE: PLAN PLUG WELD COL / CLIP S.B.S A41 SECTION A -A 2 1/2" DIA ACCESS HOLE FOR PLUD WELD HSS4x4x1 /4 RE: PLAN 3 1 /2x3 1 /2x 1 /4x 0'-3 1 /4" BASE ANGLE INSTALLED FIRST THEN HSS4x4 COL IS SLIPPED OVER BASE ANGLE AND PLUG WELDED TO VERT LEG OF BASE ANGLE FIN FL ELEV 0'-0" 5/8" DIA x4" HILTI KWIK BOLT 3 EXPANSION ANCHOR WITH 4" EMBED COLUMN BASE PLATE DETAIL S4 SCALE: NTS �1 FOOTING AT BACK CORNER S4 ELEV RE: ARCH B/ DECK ELEV VARIES T/CMU COL COVER ELEV 10'-8" OL ELEV 10'-0" CONT C8 WITH 5/8" DIA HILT[ 1 270 ADHESIVE ANCHORS @ V WITH 5" EMBEDMENT INTO GF CORES a S4 3/4" = 1'-0" , INC. ZER'S CONSULTANT: SEAL: GARY MAEDA, PE 68724 �Ka 9IAI-E Car-' (:^4 d �0 R 1Uf � THIS DRAWING SHALL NOT BE USED FOR CONSTRUCTION PURPOSES UNTIL THE SEAL AND SIGNATURE OF THE RESPONSIBLE REGISTRANT APPEARS ON THE DRAWING, AND PROPER PERMIT FORMS AND RELATED FEES ARE TRANSMITTED BY THE OWNER, OWNER'S AGENT OR CONTRACTOR TO THE AUTHORITY HAVING JURISDICTION. DATE ISSUED FOR REV 09/27/2018 PEMB COORDINATION 11/27/2018 OWNER REVIEW 12/18/2018 PERMIT SUBMITTAL Project Manager Drawn L. LONG D. GRIFFIN Project Leader Checked L. LONG Date Dept Mgr Approval 08/07/2018 G MAEDA Client PALMETTO ZEPHYRHILLS-20th St, LLC P.O. BOX 1615 THOMASVILLE, GA 31 792 Office: (229) 226-0682 Contact: ,John Tate Project DOLLAR GENERAL 38965 CR 54 Zephyrhills, FL 33542 (City of Zephyrhills) Store #: 20360 Drawing Title SECTIONS AND DETAILS DO NOT SCALE DRAWING Project No. Drawing No. JCDT.I 8.0233 S4 1) CONCRETE SALES FLOOR PRE -INSTALLATION CONFERENCE _ A. At least 30 days prior to the start of the concrete slab construction, the general contractor shall conduct a meeting to review the proposed concrete mix designs and to discuss the required methods and procedures to achieve the requirements of this specification. The general contractor shall send a pre -concrete conference agenda to all attendees scheduled date of the conference. B. The general contractor shall require responsible representatives of every party concerned with the concrete work to attend the conference, including, but not limited to, the following: General contractor's superintendent 1. Laboratory responsible for concrete mixes, field quality control and floor tolerance testing 2. Ready -mix concrete producer 3. Concrete contractor 4. Chemical admixture manufacturer 5. Liquid densifier and sealer manufacturer 6. Liquid densifier and sealer applicator 7. Joint filling manufacturer 8. Joint filling applicator C. Minutes of the meeting shall be recorded, typed and printed by the general contractor and distributed to all concerned parties, including the owner's representative, the architect and the structural engineer, within five days of the meeting. D. The minutes shall include a statement by the concrete supplier stating that the proposed concrete mix design will produce the concrete quality required by these specifications. E. The minutes shall include a statement by the concrete contractor that the proposed concrete mix design will provide appropriate workability and setting times, to ensure that the concrete contractor can achieve the requirements of this specification. CONCRETE CONTRACTOR QUALIFICATION A. The concrete contractor shall include in their bid package to the general contractor, sufficient data, including a minimum of three similar and successful projects that clearly indicates the concrete contractor's ability to successfully perform the work and to achieve the interior sales floor slab tolerances required in this specification. The concrete contractor's team shall have participated in the majority of these projects, and that team shall remain the same through the duration of this project. 3) CONCRETE MATERIALS A. Portland Cement: ASTM C 150, Type 1. Use one brand of cement throughout the project. B. Coarse and fine aggregates: ASTM C 33. Combined aggregate gradation for slabs on grade and other designated concrete shall be 8% - 18% for large top size aggregates (1'/") or 8% - 22% for smaller top size aggregates (1" or:K") retained on each sieve below the top size and above the no. 100 sieve. Slabs on grade shall have a maximum aggregate size of 11/" footings and piers 1" and beams 3/4". C. Water: complying with ASTM C 94. D. Air -entraining admixtures: Shall conform to ASTM C-260. Admixture manufacturer shall provide written certification that the air -entraining admixture is compatible with other required admixtures. All exterior slabs shall be air -entrained (4% - 6%). Acceptable products: Euclid Chemical AEA-92 or Air 40; BASF Micro Air; W.R. Grace Daravair 1000 or Darex- 1. 1. Note: Air -entraining admixture shall not be used on interior concrete. E. Water -reducing admixture: Shall conform to ASTM C494, Type A and contain no more than 0.05% chloride ions. Acceptable products: Euclid Chemical Eucon series; BASF Pozzolith series; W.R. Grace WRDA or Daracem series. F. Water -reducing, retarding admixture: Shall conform to ASTM C494, Type D, and contain no more than 0.05% chloride ions. Acceptable products: Euclid Chemical Retarder 75; BASF Pozzolith series; W.R. Grace Daratard 17. G. High range water -reducing admixture (superplasticizer): Shall conform to ASTM C494, Type F or Type G and contain no more than 0.05% chloride ions. Acceptable products: Euclid Chemical Eucon 37; BASF Rheobuild 1000; W.R. Grace daracem-100. H. Water -reducing, non -corrosive accelerating admixture: Shall conform to ASTM C494, Type C or E, and contain no more chloride ions than are present in municipal drinking water. The admixture manufacturer must have long-term, non -corrosive test data from an independent testing laboratory (of at least a year's duration) using an acceptable accelerated corrosion test method such as that using electrical potential measures. Acceptable products: Euclid Chemical Accelguard 80/90 or Accelguard NCA; BASF NC534 or Pozzutec 20; W.R. Grace Polarset. I. Prohibited admixtures: 1. Calcium chloride or admixtures containing more than 0.05% chloride ions are not permitted. 2. Flyash is not permitted. 4) EVAPORATION RETARDER : A. Waterborne, monomolecular film forming, manufactured for application to fresh concrete. 1. Acceptable products: a. "Eucobar" by Euclid Chemical - Phil Brandt 877-438-3826 5) CURING MATERIALS : A. Exterior curing : All exterior concrete slabs shall be cured using a liquid membrane -forming curing compound. The liquid membrane -forming curing compound shall meet the requirements of ASTM C1315 with a maximum V.O.C. Content of 700 g/I. 1. Acceptable products: a. "Super Rez Seal" or "Super Aqua Cure" by Euclid Chemical - Phil Brandt 877-438- 3826 B. Interior curing (building not enclosed/sales floor slab is placed first ): The interior sales floor slab shall be cured using a reduced odor, dissipating liquid membrane forming curing compound that is formulated from hydrocarbon resins. The dissipating liquid membrane forming curing compound shall meet the requirements of ASTM C309 and V.O.C. contents in accordance to EPA 40 CFR, part 59, table 1, subpart D for concrete curing compounds with a maximum V.O.C. content of 350g/I. 1. Acceptable product: a. "Kurez DR VOX" by Euclid Chemical - Phil Brandt 877-438-3826 C. Interior curing (building enclosed/sales floor slab is placed last): The interior sales floor slab shall be cured using a removable, low odor, fast drying liquid membrane forming curing compound. The removable liquid membrane forming curing compound shall meet the requirements of ASTM C309, AASHTO M 148, USDA compliancy and V.O.C. contents in accordance tb EPA 40 CFR, part 59, Table 1, subpart D for concrete curing compounds with a maximum V.O.C. Content of 350g/l. 1. Acceptable product: a. "Kurez RC" by Euclid Chemical - Phil Brandt 877-438-3826 6) LIQUID DENSIFIER / SEALER FOR INTERIOR SALES FLOOR A. Liquid densifier / sealer shall be a sodium silicate / siliconate blend. Manufacturer of liquid densifier and sealer must be contacted prior to bidding for pricing and application requirements. 1. Acceptable liquid densifier and sealer manufacturer: a, "Euco Diamond Hard" by Euclid Chemical - Phil Brandt 877-438-3826 b. "RetroPlate 99" by RetroPlate Systems - Curtis Turnbull 888-942-3144 B. Approval: All general contractors bidding or negotiating a Dollar General project shall contact Euclid Chemical or RetroPlate to obtain a list of approved applicators located within the geographic region of the project. General contractors shall solicit and accept pricing only from those applicators as provided by Euclid Chemical or RetroPlateThe approved applicator selected for the initial application of liquid densifier / sealer shall be the same as for the joint filling and additional application of liquid densifier / sealer and polishing process. Within ten days after completion of work, the approved applicator shall furnish Euclid Chemical or RetroPlate a copy of the invoice, as well as square footage and coverage rate data confirming that the specified application rates were achieved. C. Project service: at leasil0 days prior to application of liquid densifier and sealer, the general contractor shall notify the Euclid Chemical or RetroPlate representative for jobsite service. The representative will be on the project site during the first application of liquid densifier / sealer and will follow the project through to 20 days to the completion. 7) SEMI -RIGID POLYUREA JOINT FILLER: A. UV Resistant, semi -rigid polyurea joint filler shall be a two (2) component, 100% solids compound, with minimum Shore "A" hardness of 80. Joint filler color shall match the adjacent concrete surface. 1. Acceptable semi -rigid polyurea joint filler manufacturer: a. "Euco QWIKJoint UVR" by Euclid Chemical - Phil Brandt 877-438-3826 B. Non -UV Resistant, semi -rigid polyurea joint filler shall be a two (2) component, 100% solids compound, with a minimum Shore "A" hardness of 75. Joint filler color shall match the adjacent concrete surface. 1. Acceptable semi -rigid polyurea joint filler: a. "CreteFill Pro 75" by CureCrete - Curtis Turnbull 888-942-3144 C. Approval: All general contractors bidding or negotiating a Dollar General project shall contact the Euclid Chemical company or Retroplate to obtain a list of approved applicators located within the geographic region of the project. General contractors shall solicit and accept pricing only from those applicators as provided by Euclid Chemical or RetroPlateThe approved applicator selected for the initial application of liquid densifier / sealer shall be the same as for the joint filling and additional application of liquid densifier / sealer and polishing process. 8) CONCRETE MIXES: A. Comply with ACI 301 requirements for concrete mixtures. B. Concrete mix design(s) shall be proportioned according to ACI 301, for normal -weight concrete determined by either laboratory trial mix or field test data as follows: 1. Compressive strength (28 days): 4000psi (27.6mpa), with a maximum water/cement ratio of .53, unless otherwise indicated on the drawings. Concrete materials included in the mix design shall be the same materials provided to the project, and shall be prepared by an independent testing laboratory approved by the owner. If sufficient backup data is not available, the laboratory mix design shall exceed the desired job strength of concrete by 1,200psi. Four copies of the mix design shall be submitted to the owner before concrete work begins. 2. Slump: Concrete containing mid or high range water reducer shall have a maximum slump of 5'/2" for the interior sales floor slab and 8" (200 mm) for other areas. All other concrete shall not exceed 4 inches (100 mm) unless otherwise indicated on the drawings. 3. Adjustment to concrete mixes: Mix design adjustments may be requested by General Contractor when characteristics of materials, job conditions, weather, test results or other circumstances warrant; at no additional cost to owner and as accepted by owner. Laboratory test data for revised mix design and strength results must be submitted to and accepted by owner before using in work. Both the concrete testing and inspection agency and the concrete contractor shall satisfy themselves that the concrete mix design will produce a concrete which will meet the specifications for this project. In addition, the General Contractor and Concrete Contractor shall verify that the workability, finishability and setting times are appropriate for slab installations. Placement shall be made directly from concrete trucks by chute. If pumping of the concrete is contemplated for any special locations, the proportions established above shall not be altered to suit the capabilities of the pumping equipment. For concrete containing macro -synthetic fibers, adjustments required to provide required placement conditions may warrant use of additional water reducer. No additional water is permitted into concrete mixture after addition of macro -synthetic fibers. 4 Interior concrete sales floor: Concrete shall be designed to meet 4000 psi compressive strength @ 28 days and exhibit<0.04% shrinkage @ 28 days. The mix shall contain approximately 12 cubic feet of #467 aggregate (1-1/2" top size), the specified water reducing admixture and achieve a w/cm ratio of 0.53 (max.). Concrete shall be non air -entrained and in no case shall the concrete be designed for less than 4000 psi (27.6mpa) @ 28 days. Proposed mix design shall be similar to the following Prototype mix: Materials Cement Fly ash/slag Coarse aggregate Fine aggregate Water content Air content (Entrapped Air Only) Water Reducer (type a/f) W/cm Initial slump (water) Final Slump (with water reducer) Shrinkage Prototype mix 517-564lbs. Prohibited 12 cubic feet +/- .50 (#467 stone) 7 cubic feet +/- (adjust as necessary) 250 - 300lbs. 3.0% (max.) 3oz.- 1 0oz./1 00wt +/- (mid range preferred) 0.53 (max.) 3" 5.5" (max) <0.04% @ 28 days 9) FLOOR SLAB FINISH AND TOLERANCES : A. General: Unless otherwise noted by owner, concrete sales floor slab shall be cast in one continuous placement. Concrete shall be placed, screeded, re -straightened, and finished as necessary to meet the FF and FL tolerance requirements. Do not wet concrete surfaces during finishing operations. B. Trowel finish (sales floor): Apply a hard trowel finish to surfaces as follows: 1. Laser screeds, vibratory screeds, highway straightedges and wood bull floats shall be used to initiate screeding and floating process to form a uniform and open -textured surface plane before excess moisture or bleed water appears on the surface. A back-up laser screed is required during concrete placement of the interior sales floor slab. Remove excess water before starting floating operations. Do not further disturb surfaces before starting finishing operations 2. Highway straightedge operations shall continue before, during and after troweling operation, until specified floor tolerances are achieved. 3. Trowel finish with gas operated troweling machine with adjustable blades on all finishing equipment. Use steel -reinforced blades on ride -on power trowels. Trowel the surface sufficiently to produce a smooth, tight, abrasion resistant surface. Care shall be taken not to overwork or burn the surface. Use 6" wide finish style steel -reinforced blades on final passes. Finishing blades shall be in new condition and completely clean of any deleterious materials]nterior machine trowel finish shall be achieved within a 3" tolerance of all walls, columns and partitions. 4. Protection: Care shall be taken to protect the interior sales floor. Entrances shall include clean floor mats to prevent mud stains and all equipment on the floor shall be diapered to prevent spills. Cutting oils, etc, are not allowed on the sales floor slab at any time during the construction process. C. Comply with ACI 117, "Specifications For Tolerances For Concrete Construction and Materials." Interior sales floor slab shall meet the requirements of a type 5, single course, hard steel -troweled finish as described in ACI 302. 1, All perimeter areas and edges of the concrete floor shall exhibit the same finish as the sales floor, including but not limited to, hallways, offices, restrooms, etc, 2.The general contractor is responsible for contracting with the testing laboratory for all costs associated with floor tolerance testing. A copy of the final floor tolerance report shall be provided by the general contractor to the owner within 24 hours of receiving the report from the testing IaboratoryThe sales floor slab shall conform to the following flatness and levelness criteria: Flatness Overall Floor Flatness rating of at least 35 Levelness Overall Floor Levelness rating of at least 30 Tolerance Band for Entire Floor +/- 0.375 inch D. Failure to achieve the above criteria shall be cause for replacement of the offending segments or grinding/polishing at no cost to the Owner or Tenant. E. Trowel finish (other than sales floor): Apply a hard trowel finish to surfaces indicated and to floor and slab surfaces exposed to view or to be covered with resilient flooring, carpet, ceramic or quarry tile set over a cleavage membrane, paint, or another thin film -finish coating system. F. Heavy broom finish: As noted on drawings. 10) CONCRETE PROTECTION AND CURING: A. General: Normalize concrete set time and protect freshly placed concrete from premature drying and excessive cold or hot temperatures. Comply with ACI 305 for hot -weather protection and ACI 306 for cold -weather protection during curing. During concrete placement operations, ventilate and exhaust all fumes from construction equipment and heaters to avoid potential early concrete carbonation. Apply the specified curing compound as quickly as possible for maximum protection. For concrete placement during hot, dry and windy conditions, concrete contractor shall use evaporation retarder as per manufacturer's instructions to maintain a moist condition and to minimize plastic drying shrinkage cracking at the surface of the freshly placed concrete. 1. Curing - Exterior Slabs: All exterior concrete slabs shall be cured using the specified liquid membrane -forming curing compound. Per manufacturer's instructions, application shall be applied evenly and uniformly as soon as possible after final finishing. Surface shall be clean and damp, but not wet and can no longer be marred by walking workmen. All applications shall be made by an approved applicator of the manufacturer, and when surface and air temperature is above 501 f. Apply "Super Rez Seal" or "Super Aqua Cure" at an application rate of 400sf/gallon. Begin curing immediately after finishing concrete, but not before free water has disappeared from concrete surface. 2. Curing - Interior slabs: The interior sales floor slab shall be cured using the specified dissipating or removable liquid membrane -forming curing compound. Per manufacturer's instructions, application shall be applied evenly and uniformly as soon as possible after final finishing. Surface shall be damp, but not wet and can no longer be marred by walking workmen. All applications shall be made by an approved applicator of the manufacturer, and when surface and air temperature is above 500 f. Apply "Kurez DR VOX" (slab first) or "Kurez RC" (slab last) at an application rate of 350sf/gallon. Begin curing immediately after finishing concrete, but not before free water has disappeared from concrete surface. 11) CONTRACTION JOINTS IN SLABS -ON -GRADE: A. Form weakened -plane contraction joints, sectioning concrete into areas as indicated on drawings. Contraction joints shall be sawn to a depth equal to at least one-fourth of the concrete thickness, as follows: B. Sawed joints: All saw cutting shall be accomplished with a "Soft -Cut" saw and vacuum system equipped with a new blade and plate, as soon as the slab will support the weight of the saw and operMoite: Concrete dust shall be removed completely and immediately. If chalk lines are used for sawcuts, all chalk remaining on the slab shall be removed completely and immediately after sawing. 12) INTERIOR SALES FLOOR SLAB PROTECTION: A. Take the following measures to protect the interior sales floor slab: 1. Wrap or "diaper" all motorized and hydraulic equipment to prevent fluid leaks 2. Provide non -marking tires on rubber tired vehicles or equip rubber tires with tire boots made of nylon fabric 3. Provide mats at all entrances to prevent mud stains 13) TIMING OF JOINT FILLER, LIQUID DENSIFER AND POLISHING PROCESS: A, Do not commence installation of semi -rigid polyurea joint filler, liquid densifier and sealer or polishing processes until the buildingis completely enclosed, permanent power and lighting is operating and the building is P y P P 9 g P g g thermostatically controlled. Installation of these materials shall commence approximately two weeks prior to "fixture date." 14) INSTALLATION OF SEMI -RIGID POLYUREA JOINT FILLER: A. All General Contractors bidding or negotiating a Dollar General project shall contact Euclid Chemical or RetroPlate to obtain a list of approved applicators located within the geographic region of the project. General contractors shall solicit and accept pricing only from those applicators as provided by Euclid Chemical or RetroPlate. The approved applicator selected for the initial application of liquid densifier / sealer shall be the same as for the joint filling and additional application of liquid densifier / sealer. B. Joint filler installation: Comply with recommendations in ACI 302 for use of joint filler as applicable to materials, applications, and conditions indicated. C. Surface cleaning of joints: Clean out joints immediately before installing joint filler. Remove foreign material from joint substrates that could interfere with adhesion of joint filler by brushing, grinding, blast cleaning, mechanical abrading, or a combination of these methods to produce a clean, sound substrate capable of developing optimum bond with joint filler. Remove loose particles remaining from above cleaning operations by vacuuming or blowing out joints with oil -free compressed air. Also remove all laitance and form -release agents from concrete surface. Clean nonporous surfaces with chemical cleaners or other means that do not stain, harm substrates, or leave residues could interfere with adhesion of joint sealants. All surfaces to be filled shall be clean and dry. D. For proper load transfer, joints must be filled full depth, but in no case should the joint filler be any less than 1" deep in the joint. E. Mixing: Joint filler is a two part product requiring machine mixing and placing. Premix part b separately before using. Follow pump manufacturer's equipment instructions. F. Placement: Joint filler shall be filled full depth.No backer rod is allowed . Joints should be overfilled and shaved even with the surrounding joint edge giving the floor joints a flat, smooth appearance. Shaving of excess joint filler can be approximately 30 minutes after placement, and up to 24 hours later, depending on jobsite conditions such as concrete and ambient temperatures, G. Joint filler separation: The approved joint filling applicator shall include in their bid a cost per linear foot to make one return trip to refill joints if joint filler sidewall separation or splitting exceeds 1/16," or if surface profile is concave, chattered or if voids occur. This shall take place one week prior to grand opening. 15) INITIAL CLEANING FOR LIQUID DENSIFIER AND SEALER APPLICATION: A. Interior sales floor slab: Thoroughly clean the interior sales floor slab prior to initial application of liquid densifier and sealer by completely removing the specified dissipating or removable curing compound from the floor surface. The following floor stripper or removal solution shall be applied to the floor to thoroughly strip, clean and remove all curing compound residue: 1. If Kurez DR VOX (slab first) was used to cure the slab, use "Euco Clean & Strip" by Euclid Chemical, applied at the proper water to floor stripper ratio and coverage rate that will completely remove the Kurez DR VOX. Contact: Phil Brandt (877) 438-3826 2. If Kurez RC (slab last) was used to cure the slab, use "Kurez OFF" by Euclid Chemical, applied at the proper water to floor cleaner ratio and coverage rate that will completely remove the Kurez RC. Contact: Phil Brandt (877) 438-3826 16) POLISHING PROCESS AND APPLICATION OF LIQUID DENSIFIER / SEALER: A. All Applicators must be certified by Euclid Chemical or Retro-Plate. B. The revised process can be used in both "Wet" and "Dry" applications. C. This process assumes a quality concrete fini*eets and/or exceeds the specified floor tolerances) by the floor finisher. Failure to achieve the above criteria shall be cause for replacement of the offending segments or grinding/polishing at no cost to the Owner or Tenant. D. Only the Sales Floorwill receive the full 8 step process outlined below under item K. E. All other areas will only receive steps 1 through 3, no additional work is necessary. The yellow safety striping will remain. F. The Black painted border will not be required in areas behind fixtures, etc....it will only be installed at the main entry door, office doors, egress doors and doorways into the receiving area and transitions that can be seen by the customers. G. Steps 2 & 4 are combo steps using different grits of resin bond diamonds on each pass. H. This is a "Resin" only grind that does not tear away as much of the surface area. The Resin grind will remove a minimal top layer of the concrete surface and should greatly reduce the amount of Waste Product created when compared to the old Metal grind process. I. If a Cure-n-Seal product is required at the time of slab placement only Water Based Dissipating Sealers are allowed. NO Acrylic Cure-N-Seals are allowed. J. Prior to application, inspect interior sales floor slab to ensure that slab is clean and free of dust, grease, oils, or other contaminants that might prohibit the proper application and penetration of the liquid densifier and sealer. K. Nine Step Process: 1. Cut, clean out, prep and fill the concrete floor joints with the Euclid QWIKjoint UVR polyurea joint filler. 2. Grind conrete floor with a combo set of 40/50 grit resin bond diamonds. 3. Grind concrete floor with a combo set of 60/100 grit resin bond diamonds. 4. Thoroughly clean concrete floor and apply Diamond Hard densifier at 225 square feet per gallon. 5. Polish concrete floor with a combo set 100/200 grit resin bond diamonds. 6. Polish concrete floor with 400 grit resin bond diamonds. 7. Thoroughly clean concrete floor and then apply Diamond Hard densifier at 700 square feet per gallon. 8. Burnish / Polish concrete floor with 800 grit diamond impregnated pads. 9. Burnish / Polish concrete floor with 1500 grit diamond impregnated pads. L. All edges must be polished to match concrete floor with coinciding SASE 5" resin Polishing pads or HTC EZ Grind polishing 5" diamond tools. M. Polish results: Perform polishing process to attain an overall gloss reading of >_35 specified overall gloss value (SOGV) as measured using a Horiba IG-320, and a specified minimum gloss reading of >_30 minimum local gloss value (MGLV). A minimum of 75 readings shall be taken throughout the interior sales floor. The approved applicator shall take four gloss measurement readings at 90' from each other, and then averaged for one reading at each location. The overall measurement shall be reported to Dollar General within 24 hours of the polishing process. Gloss shall be considered as a quantitative value that expresses the degree of reflection when light hits the concrete floor surface.. Gloss measurements will be taken independent of ambient lighting and will be taken within a sealed measurement window located beneath the test unit. REQUIRED PHOTOS: The following layout shows the required photos to be taken at completion. (Make sure the overhead lights are on for your photos.) 1. From each corner of the receiving area, facing the opposite corner. 2. Hall (inside entrance stores, one picture from each end of the hall). 3. Standing 10' from the entrance facing the entrance. CONSULTANT: SEAL: GARY MAEDA, PE 68724 'n Y 1V = dr _ No.6p�8724 9TAT'E0I-- rl THIS DRAWING SHALL NOT BE USED FOR CONSTRUCTION PURPOSES UNTIL THE SEAL AND SIGNATURE OF THE RESPONSIBLE REGISTRANT APPEARS ON THE DRAWING, AND PROPER PERMIT FORMS AND RELATED FEES ARE TRANSMITTED BY THE OWNER, OWNER'S AGENT OR CONTRACTOR TO THE AUTHORITY HAVING JURISDICTION. DATE ISSUED FOR REV 09/27/2018 PEMB COORDINATION 11/27/2018 OWNER REVIEW 1 2/18/201 8 PERMIT SUBMITTAL Project Manager Drawn L. LONG D. GRIFFIN Project Leader Checked L. LONG Date Dept Mgr Approval 08/07/2018 G MAEDA Client PALMETTO ZEPHYRHILLS-20th St, LLC P,O. BOX 1615 THOMASVILLE, GA 31 792 Office: (229) 226-0682 Contact: John Tate Project DOLLAR GENERAL 38965 CR 54 Zephyrhills, FL 33542 (City of Zephyrhills) Store #: 20360 Drawing Title CONCRETE SUMMARY DO NOT SCALE DRAWING Project No. Drawing No. JCDT.18.0233 85 q f z f NORTH H VAC LAYOUT 1 Scale; 1/8"' VV-0"' SUPPLY (TYP. 2) �t 0 F TO DROP DIFFUSER GENERAL NOTES 1. GENERAL NOTES ARE APPLICABLE TO ALL HVAC DRAWINGS. 2. PERFORM WORK IN ACCORDANCE WITH THE LATEST EDITIONS, REVISIONS, AMENDMENTS, OR SUPPLEMENTS OF APPLICABLE STATUTES, ORDINANCES, CODES OR REGULATIONS OF FEDERAL, STATE, AND LOCAL AUTHORITIES HAVING JURISDICTION IN EFFECT ON THE DATE BIDS ARE RECEIVED.. 3. WHERE APPROVED STANDARDS HAVE BEEN ESTABLISHED BY OSHA, UNDERWRITERS LABORATORIES, AMERICAN CODES, ASA, ASHRAE, ARI, NEC, STATE FIRE INSURANCE REGULATION BODY, NFPA OR OTHERS. 4. THESE STANDARDS SHALL BE FOLLOWED WHETHER OR NOT INDICATED ON THE DRAWING AND SPECIFICATIONS. 5. ALL DUCT TO BE OF 2" PRESSURE CLASS, UNLESS NOTED OTHERWISE. 6. LIGHT FIXTURE LOCATIONS TAKE PRECEDENCE OVER DIFFUSER AND GRILLE LOCATIONS. LOCATE DIFFUSERS AND GRILLES TO ACCOMMODATE LIGHTING LAYOUT. 7. PROVIDE TURNING VANES IN SUPPLY DUCT ELBOWS. PROVIDE TURNING VANES IN RETURN AND EXHAUST ELBOWS ONLY WHERE INDICATED ON PLANS. 8. DUCT SIZES SHOWN ARE NET FREE AREA. 9. PROVIDE FLEXIBLE DUCT CONNECTION BETWEEN AIR CONDITIONING UNIT AND DUCTWORK. 10. WHERE SINGLE SUPPLY DUCTS SPLIT INTO TWO DUCTS MAINTAIN EACH BRANCH DUCT SIZE THROUGH SPUTTER FITTING AND PROVIDE SINGLE TRANSITION ON UPSTREAM SIDE OF SPUTTER FITTING, 11. DUCT DETECTORS SHALL BE ACCESSIBLE FOR CLEANING AND MOUNTED IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTION. ACCESS DOORS AND/OR PANELS SHALL BE PROVIDED IN ACCORDANCE WITH NFPA 90A. THE LOCATION OF ALL DETECTORS IN AIR DUCT SYSTEMS SHALL BE PERMANENTLY AND CLEARLY IDENTIFIED AND RECORDED. LEGEND T THERMOSTAT CONTROL SD SMOKE DETECTOR TS TEMPERATURE SENSOR OT OUTSIDE AIR TEMPERATURE SENSOR SUPPLY DUCT IN SECTION RETURN OR EXHAUST DUCT IN SECTION �—�- VOLUME CONTROL DAMPER FIRE DAMPER CEILING SUPPLY DIFFUSER CEILING RETURN GRILLE O NOTES BY SYMBOL CUBIC FEET CFM PER MINUTE NK NECK AFF ABOVE FINISHED FLOOR DN DOWN CD CONDENSATE DRAIN EXH. EXHAUST SA SUPPLY AIR REQ'D REQUIRED RA RETURN AIR DMPR DAMPER FD FIRE DAMPER EXIBLE CANVAS VECTION HORIZONTAL AIR SCOOP ROUND SUPPLY AIR DUCT. CONNECT BRANCH TO SUPPLY AIR DUCT DROP, ABOVE DIFFUSER. 41 VOLUME DAMPER UCT DROP trLtAIBLE DUCT NOT ALLOWED) er' SUPPLY / RETURN AIR CONCENTRIC DIFFUSER MODEL NUMBER: 01-530-22 NOTE: INSTALL HORIZONTAL AIR SCOOP HAVING A CONTINUOUSLY CURVED CROSS SECTION AND BALANCING DAMPER AT DUCT CONNECTION TO DIVERT SUPPLY AIR INTO THE CONNECTED DUCTWORK. LENGTH OF SCOOP SHALL BE LIMITED TO THE WIDTH OF THE SUPPLY AIR ANNULAR SPACE. CONCENTRIC DIFFUSERS, AVAILABLE THROUGH YORK, CAN BE USED ON ALL VENDORS EQUIPMENT. CONTACT YORK NATIONAL PRICING FOR INFORMATION. LOCATE THE BOTTOM OF DIFFUSER AT 12'-0" AFF. TYPICAL SUPPLY BRANCH CONNECTION & BLANK -OFF DETAIL .Scale: N.T.S. CONSULTANT; I / THIS DRAWING SHALL NOT BE USED FOR CONSTRUCTION PURPOSES UNTIL THE SEAL AND SIGNATURE OF THE RESPONSIBLE REGISTRANT APPEARS ON THE DRAWING, AND PROPER PERMIT FORMS AND RELATED FEES ARE TRANSMITTED BY THE OWNER, OWNER'S AGENT OR CONTRACTOR TO THE AUTHORITY HAVING JURISDICTION. DATE ISSUED FOR REV 09/27/201 8 PEMB COORDINATION 11/27/2018 OWNER REVIEW 12/1 8/201 8 PERMIT SUBMITTAL Project Manager Drawn L. LONG T. PATTERSON Project Leader Checked L. LONG H. MONTAGUE Date Dept Mgr Approval 08/07/2018 H. MONTAGUE Client PALMETTO ZEPHYRHILLS-20th St, LLC P.O. BOX 1615 THOMASVILLE, GA 31 792 Office: (229) 226-0682 Contact: .John Tate Project DOLLAR GENERAL 38965 CR 54 Zephyrhills, FL 33542 (City of Zephyrhills) Store #: 20360 Drawing Title HVAO LAYOUT DO NOT SCALE DRAWING Project No. Drawing No. .JCDT.18.0233 M1 u GENERAL HVAC NOTES 1. ALL MECHANICAL EQUIPMENT SHALL BE PROVIDED WITH PROPER CLEARANCE. A MINIMUM OF 48" IS CONSIDERED SUFFICIENT SPACE AROUND AIR HANDLING UNITS, 2017 F.B.C.M. 2. ALL DUCT SYSTEMS INSTALLED IN UNCONDITIONED AREAS SHALL BE CONSTRUCTED WITH APPROVED MATERIAL AND OF A VALUE OF NO LESS THAN R-4.2 RATING. DUCT SYSTEMS AT THE EXTERIOR OF A BUILDING SHALL BE CONSTRUCTED WITH A A VALUE OF NO LESS THAN R-6 RATING. ALL SEAMS SHALL BE SEALED WITH GLASS FAB & MASTIC "OR" APPROVED TAPES THAT EXTEND NOT LESS THAN 1 INCH AND LABELED IN ACCORDANCE WITH THE UL-181A, PART 1 FOR DUCT BOARD OR UL 181 B, PART 1 FOR FLEX. ALL CLOSURES AND INSTALLATIONS SHALL BE INSTALLED AS PER 2017 F.B.C.M. ALL THRU-WALL, FLOOR & CEILING PENETRATIONS INTO THE DUCT SECTION SHALL CONTAIN A BRANCH DUCT FABRICATED OF RIGID FIBROUS GLASS DUCT BOARD OR RIGID METAL AND IS SEALED TO BOTH DUCT SECTION AND GRILLE SIDE WALL SURFACE. 3. FABRICATE AND ERECT ALL DUCTWORK TO SMACNA STANDARDS FOR GALVANIZED STEEL. COMPLY WITH NFPA 90A REQUIREMENTS, 4. DUCTWORK SHALL BE SMACNA LOW PRESSURE CONSTRUCTION 2" STATIC PRESSURE RATING WITH SEAL CLASS B SEAMS AND JOINTS. 5. INCLUDE ALL ACOUSTIC, AIRFOIL SHAPED PERFORATED ALUMINUM TURNING VANES, MANUAL DAMPERS, FLEXIBLE CONNECTORS, GRILLES AND DIFFUSERS, ACOUSTIC LINING, AND OTHER SHEET METAL ACCESSORIES FOR THE PROJECT. 6. ALL BRANCH CONNECTIONS SHALL BE AS PER THE DETAILS SHOWN ON THE DRAWINGS. 7. ACOUSTICALLY LINE ALL RECTANGULAR DUCTS INDICATED ON DRAWINGS WITH ONE (1) INCH THICK NON -FLAKING, COATED MEDIUM DENSITY LINER, WITH 0.26 THERMAL CONDUCTIVITY, MAXIMUM FLAME SPREAD RATING OF 25 AND SMOKE DEVELOPED RATING OF 50, CONFORM TO MANUFACTURER'S RECOMMENDATIONS. 8 DUCT DIMENSIONS INDICATED ON DRAWINGS ARE CLEAR INSIDE DIMENSIONS (FREE AREA) HVAC UNIT SCHEDULE FAN COOLING HEATING ELECTRICAL DIMENSIONS UNIT EQUIPMENT AREA SERVED HXWxL WEIGHT MODEL NO. REMARKS TAG AIRFLOW (CFM) DRIVE MIXED AIR LAT TOTAL SENSIBLE INPUT MAT LAT SUPPLY FAN (IN) (LB) CONTROL TYPEESP (MBH) (MBH) EER/SEER (KW) °F °F MOTOR VOLT PHASE MCA MOCP OUTSIDE °F °F (HP) SUPPLY AIR DB WB -F AIR BUSKIN CONCENTRIC DIFFUSER KIT RTU-1 REAR RETAIL, 3100 970 MULTI -STAGE BELT .8 80.9 69.0 59.3 105.9 69.4 1 1.2/13.2 30.0 58.3 78.7 2.0 208 3 92.0 100 49x61 x96 1800 ZCA120S4M 530 SERIES REFER TO DETAIL 2 ON RECEIVING AIR VOLUME SHEET M1 FOR MODEL NUMBER FRONT RETAIL, RUSKIN CONCENTRIC DIFFUSER KIT RTU-2 TOILETS, BREAK ROOM, 3100 890 MULTI -STAGE BELT .8 80.5 68.5 59.4 107.2 68.0 1 1 .2/1 3.2 30.0 58.4 80.0 2.0 208 3 92.0 100 49x61 x96 1800 ZCA1 20S4M 530 SERIES REFER TO DETAIL 2 ON OFFICE AIR VOLUME SHEET M1 FOR MODEL NUMBER 9. FURNISH ALL MATERIAL LABOR AND EQUIPMENT AS REQUIRED TO INSTALL COMPLETE PLUMBING AND HVAC INSULATION AS INDICATED ON MECHANICAL B NOTES: 1. MODEL NUMBERS ARE BASED ON LENNOX (LENNOX NATIONAL ACCOUNTS: 1-972-497-6249; TERRITORY REPRESENTATIVE SCOTT MACDONALD, EMAIL: SCOTT.MACDONALD@LENNOXIND.COM DRAWINGS AND IN THESE SPECIFICATIONS. 2. SCHEDULED CAPACITIES ARE REQUIRED VALUES. 10. INSTALL IN FULL ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. 3. UNIT SHALL COMPLY WITH UL, NEC, NFPA 70 AND ASHRAE 90.1 2013. 11. PLUMBING INSULATION (AS MANUFACTURED BY OWENS CORNING, KNAUF, SCHULLER OR CERTAINTEED) 4. PROVIDE DIFFERENTIAL ENTHALPY ECONOMIZER, BAROMETRIC RELIEF DAMPER, DUAL ENTHALPY SENSOR, 2" PLEATED MERV 13 AIR FILTERS, FACTORY INSTALLED PACKAGE WITH UNIT DISCONNECT, STARTER, PHOTO -ELECTRIC SMOKE DETECTOR IN SUPPLY DUCT AND FACTORY INSTALLED MULTI -STAGE 12. INSULATE ALL ABOVE GRADE HOT AND COLD WATER PIPING WITH MOLDED FIBER GLASS HAVING AN ALL SERVICE JACKET. AIR VOLUME BLOWER KIT WITH VARIABLE FREQUENCY DRIVE. 13. INSULATION THICKNESS SCHEDULE: 1) LESS THAN 2" DIAMETER PIPE: 1" THICK; 2 2"-8" DIAMETER PIPE: 1-112" THICK. 5. ELECTRICAL DATA, DIMENSIONS AND WEIGHTS ARE BASED ON THE "BASE BID" UNIT. IF ALTERNATE MANUFACTURERS ARE USED, COORDINATE CHANGES WITH ELECTRICAL, STRUCTURAL AND ARCHITECTURAL TRADES. ANY ADDITIONAL COSTS DUE TO CHANGES RESULTING FROM USE OF 14. INCLUDE INSULATION OF FITTINGS AND VALVES. KEEP VAPOR BARRIERS INTACT. CONFORM TO MANUFACTURER'S RECOMMENDATIONS. ALTERNATE MANUFACTURERS SHALL BE THE RESPONSIBILITY OF THE MECHANICAL CONTRACTOR 15. _ ADA COMPLIANT LAVATORY INSULATION INSULATE ALL EXPOSED WASTE AND WATER SUPPLY PIPING UNDER LAVATORY WITH SAFETY COVERS PER 6. MANUFACTURER TO SPECIFY CONCENTRIC DIFFUSER AS PART OF A PACKAGED KIT. CONTRACTOR TO CONFIRM AVAILABLE CEILING SPACE BEFORE ORDERING. PROTOTYPICAL PACKAGED KIT DUCT LENGTHS MAY NEED TO BE SHORTENED. ADA REQUIREMENTS. 7. MOUNT HVAC UNITS ON ROOF. ROOF CURB BY PEMB MANUFACTURER. COORDINATE WITH PEMB MANUFACTURER FOR ROOF CURB AND ROOF OPENING DIMENSIONS. 16. HVAC INSULATION (AS MANUFACTURED BY OWENS CORNING, KNAUF, SCHULLER, OR CERTAINTEED). INSULATE ALL NON -LINED SUPPLY, RETURN, AND 8. WATER LEVEL MONITORING DEVICE CAPABLE OF SHUTTING DOWN RTU SHALL BE INSTALLED ON THE PRIMARY CONDENSATE DRAIN PAN. EXHAUST DUCTS WITH 1-1/2" THICK FOIL FACED REINFORCED KRAFT JACKET, FIBERGLASS DUCT WRAP FULLY SECURED TO DUCT. LAP AND TAPE SEAMS AND SECURE TIGHTLY TO THE DUCTS WITH WIRE OR STICK PINS. ALL INSULATION TO BE APPLIED IN FULL ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS AND COMPLY WITH 25150 FLAME AND SMOKE HAZARD RATINGS PER ASTM E-84, NFPA 255 AND UL 723. 17. EXTERIOR DUCTWORK SHALL BE INSULATED WITH 2" THICK FIBERGLASS DUCT WRAP, WITH ALUMINUM JACKET, SEALED WATERTIGHT. 18. DUCT LINER SHALL COMPLY WITH NFPA 90A AND 90B (LATEST EDITION) REQUIREMENTS AND NAIMA "FIBROUS GLASS DUCT LINER STANDARD". 19. FLEXIBLE DUCTWORK (AS MANUFACTURED BY CLEVAFLEX, FLEXMASTER OR WIREMOLD). FLEXIBLE DUCTS SHALL BE INDEPENDENTLY SUPPORTED FROM THE STRUCTURE AND CONNECTED WITH PLASTIC DRAW BANDS AND TIGHTENED. FLEXIBLE DUCTS SHALL BE LIMITED TO 7' MAXIMUM STRAIGHT LENGTHS. FLEXIBLE DUCTS SHALL BE CONSTRUCTED OF 1 1/2" INSULATION WITH VINYL VAPOR BARRIER JACKET AND RATED AT 10" WC FOR SIZES THROUGH 12", UL LISTED, AND MEET 25/50 FLAME AND SMOKE TEST. FLEXIBLE DUCTS ARE NOT PERMITTED IN ROOMS WITHOUT CEILINGS. 20. ALL DUCT TRUNK 90 DEGREE TURNS OR TEES, SHALL HAVE TURNING VANES. 3 PIECE OR 45 DEGREE TURNS CAN BE USED IN PLACE OF 90 DEGREE TURNS AND DO NOT NEED TURNING VANES. 21. ALL REGISTERS, GRILLES & DIFFUSERS MUST BE TESTED IN ACCORDANCE WITH ASTM E 84, AND VOLUME DAMPERS OR OTHER MEANS OF SUPPLY AIR ADJUSTMENT SHALL BE PROVIDED IN DUCTS OR AT EACH INDIVIDUAL REGISTER, GRILLE OR DIFFUSER.. 22. CONSTRUCTION DOCUMENTS SHALL REQUIRE THAT A WRITTEN BALANCE REPORT BE PROVIDED TO THE OWNER OR THE DESIGNATED REPRESENTATIVE OF THE BUILDING OWNER FOR HVAC SYSTEMS SERVING ZONES WITH A TOTAL CONDITIONED AREA EXCEEDING 5000 SQ. FT. AIR DISTRIBUTION SYSTEMS SHALL BE TESTED, ADJUSTED AND BALANCED BY A LICENSED ENGINEER OR A COMPANY OR INDIVIDUAL HOLDING A CURRENT CERTIFICATION FROM A RECOGNIZED TESTING AND BALANCING AGENCY ORGANIZATION IN ACCORDANCE WITH GENERALLY ACCEPTED ENGINEERING STANDARDS. F.B.C.M. 2017 EXCEPTIONS: 1) BUILDINGS WITH COOLING OR HEATING SYSTEM CAPACITIES OF 15 TONS OR LESS PER SYSTEM MAY BE TESTED AND BALANCED BY A MECHANICAL CONTRACTOR LICENSED TO DESIGN AND INSTALL SUCH SYSTEMS. 2) BUILDINGS WITH COOLING OR HEATING SYSTEM CAPACITIES OF 65,000 BTU/H OR LESS PER SYSTEM ARE EXEMPT FROM THE REQUIREMENTS OF THIS SECTION. F.B.C.M. 2017. 23. SMOKE DETECTORS SHALL BE INSTALLED IN BOTH SUPPLY & RETURN AIR SYSTEMS WITH A DESIGN CAPACITY GREATER THAN 2000 CFM, IN THE RETURN AIR DUCT OR PLENUM UPSTREAM OF ANY FILTERS, EXHAUST AIR CONNECTIONS, OUTDOOR AIR CONNECTIONS, OR DECONTAMINATION EQUIPMENT AND APPLIANCES, F.B.C.M. 2017. WHERE MULTIPLE AIR HANDLING SYSTEMS SHARE COMMON SUPPLY OR RETURN AIR DUCTS OR PLENUMS WITH A COMBINED DESIGN CAPACITY GREATER THAN 2000 CFM, THE RETURN AIR SYSTEM SHALL BE PROVIDED WITH SMOKE DETECTORS IN ACCORDANCE WITH F.B.C.M. 2017. SMOKE DETECTORS SHALL BE INSTALLED IN ACCORDANCE WITH NFPA 72, SMOKE DETECTOR TEST STATIONS SHALL HAVE A TROUBLE INDICATOR LIGHT, INUNDATING ANY AIR DUCT TROUBLE. NFPA 90A 2002, CHAPTER 6 NOTE: A "PLENUM" CAN NOT BE USED AS AN OCCUPANCY SPACE OR STORAGE AREAS. AS PER. NFPA-90A. 24. FIRE DAMPERS (AS MANUFACTURED BY RUSKIN, NAILOR OR SAFE -AIR). FABRICATE IN ACCORDANCE WITH NFPA 90A AND UL555, F.B.C.M.2017. DAMPERS SHALL BE SUITABLE FOR USE IN THE VERTICAL OR HORIZONTAL POSITION AS INDICATED ON THE DRAWINGS BE TYPE'B' WITH BLADES OUT OF MINIMUM OUTDOOR AIR SCHEDULE ROOM NAME SERVED BY AREA (SQ. FT.) OA REQ'D PER AREA (CFM/SF) OCCUPANCY PEOPLE /1000 SQ.FT.) OCCUPANCY (NUMBER OF PEOPLE) OA REQ'D PER PERSON (CFM) UNCORRECTED OA REQ'D ADJUSTED OA (CFM) REMARKS REAR RETAIL RTU-1 3730 .12 15 56 7.5 867 RECEIVING RTU-1 880 .12 0 2 5 106 RTU-1 TOTAL 973 1100 BREAK ROOM RTU-2 100 .06 _ 5 2 5.0 16 OFFICE RTU-2 80 .06 5 1 5.0 7 FRONT RETAIL RTU-2 3730 .12 15 56 7.5 867 RESTROOMS RTU-2 130 0 0 0 0 0 154 CFM EXHAUST RTU-2 TOTAL 890 1020 AIRSTREAM, AND BE RATED FOR 1-1/2 HOURS MINIMUM (UNLESS NOTED OTHERWISE). NOTE: BASED ON 2017 FLORIDA MECHANICAL CODE & ASHRAE 90.1-201 3 25. FIRE AND SMOKE DAMPERS SHALL BE PROVIDED WITH AN APPROVED MEANS OF ACCESS, LARGE ENOUGH TO PERMIT INSPECTION AND MAINTENANCE OF THE DAMPER AND ITS OPERATING PARTS. PROVIDE DUCT MOUNTED ACCESS DOORS AT ALL FIRE DAMPER LOCATIONS. ACCESS DOORS (AS MANUFACTURED BY RUSKIN, NAILOR OR SAFE -AIR), FABRICATE IN ACCORDANCE WITH SMACNA STANDARDS. DOORS TO BE FABRICATED OF GALVANIZED STEEL WITH SEALING GASKET AND QUICK LOCKING DEVICE. FOR INSULATED DUCTWORK, DOORS SHALL HAVE MINIMUM ONE (1) INCH INSULATION WITH SHEET METAL COVER. 26. FRESH AIR INTAKES SHALL NOT BE LOCATED CLOSER THAN 10 FT. FROM ANY CHIMNEY, EXHAUST OR VENT OUTLET, OR SANITARY SEWER VENT OUTLET. 27. ALL EXHAUST DUCTS, SHALL BE CONSTRUCTED OF GALV. METAL F.B.C.M. 2017 28. ALL EXHAUSTED BATHROOMS, CLOSETS & STORAGE ROOMS SHALL HAVE UNDER CUT DOORS OR A METHOD FOR MAKE UP AIR TO BE TRANSFERRED EQUAL TO THE AMOUNT OF CFM'S EXHAUSTED, F.B.C.M. 2017 29. CONDENSATE FROM ALL COOLING COILS AND EVAPORATORS SHALL BE CONVEYED FROM THE DRAIN PAN OUTLET TO AN APPROVED PLACE OF DISPOSAL CONDENSATE SHALL NOT DISCHARGE INTO A STREET ALLEY OR OTHER AREA AS TO CAUSE A NUISANCE MUST TERMINATE A MIN OF 18" DESIGN CONDITIONS CONDITION SUMMER (ASHRAE 0.4%) WINTER (ASHRAE 99.6%) OUTDOOR 94.0-F DB/76.0-F WB 37°F DB INDOOR 75-F DB/50% RH 68°F DB FROM EXT. WALL. PER AUTHORITY OVER JURISDICTION CONDENSATE DRAIN MAY DRAIN TO A STORM SYSTEM, UTILITY SINK, OR SEWER BY APPROVED WEATHER STATION: ORLANDO, FL MEANS. CONDENSATE DRAIN LINE SHALL NOT BE LESS THAN 3/4 INCH DIAMETER AND SHALL NOT DECREASE IN SIZE. 2017 F.B.C.M. FOUR (4) #10 TEK SCREWS WITH 18 HEX WASHER HEAD �. CEILING N `= MOUNTED FLOOR RIGID _l FAN ABOVE OR CONNECTION RooF N ` -�...".✓ PRESSURE TREATED WALL CAP W/ 311/16" NAI BACKDRAFT RS LE _.. DAMPER RESTRAINT BRACKET 10 GA GALVANIZED CONSTRUCTION (8 PER UNIT) (2 PER SIDE. EACH LOCATED 6" FROM CORNER). NOTE: A SUBSTITUTE UNIT TIE -DOWN SYSTEM UTILIZING 1 1/2"x6" GALVANIZED LAG SCREWS THROUGH UNIT FRAMING, WOOD NAILER AND CURB FRAME INSERTED AT 6" FROM EACH CORNER ON ALL (4) SIDES AND SPACED AT A MAXIMUM OF 24" ON CENTER FOR THE ENTIRE LENGTH OF EACH SIDE MAY BE USED IN LIEU OF THE ABOVE SPECIFIED TIE -DOWN SYSTEM. CONTRACTOR SHALL RECEIVE WRITTEN APPROVAL, FROM THE LOCAL AUTHORITY HAVING JURISDICTION, PRIOR TO INSTALLATION. CURB AND UNIT TIE -DOWN DESIGN MUST MEET SEISMIC & WIND LOAD REQUIREMENTS FOR 2017 FLORIDA BUILDING CODE & 2017 FLORIDA MECHANICAL CODE. LOCATION: PASCO COUNTY WIND SPEED (MPH): 115 1 MECH. UNIT TIE DOWN N.T.S. 3/4" RED MALE ADAPTER FOR 3 TO 12-1 /2 TON RTU (I" MPT X S MALE ADAPTER FOR 15 TON RTU) 1 " MPT GALV 1 " PVC 90` NIPPLE STANDARD FOR 1 5T RTU ELBOWS DRAIN PAN RTU I 1 " RETURN `BEND, PVC AIR GAP=2x PIPE DIA (MIN) DRAIN @ ROOF GUTTER -- ____---�---_ 2° MIN._..._._. FINISHED ROOF ROOF CURB DRAIN PLUG CONDENSATE PIPING CONNECTION DETAIL N.T.S. �� RIGID �� CEILING EXHAUST INSUL } GRILLE DUCT - CUR BATHROOM EXHAUST FAN DETAIL N.T.S. R.A. DUCT ROOF CURB PURLIN HANG PER SMACNA GENERAL CONTRACTOR SHALL COORDINATE FINAL SELECTION OF ROOF MOUNTED EQUIPMENT CURBS AND LOCATIONS WITH PEMB MANUFACTURER PRIOR TO FABRICATION. PROVIDE CONCENTRIC DIFFUSER TO BE SPECIFIED BY MANUFACTURER AS r PART OF A PACKAGED KIT. REFER TO DETAIL 2 ON SHEET M1 FOR MODEL NUMBER. ALTERNATE MANUFACTURER SHALL PROVIDE DIFFUSER KIT COMPARABLE TO BASIS OF DESIGN. STRUCTURALI [ STEEL 3 HVAC ROOF CURB DETAIL N.T.S. UNIT ROOF S.A. DUCT FLEXIBLE CONNECTION FACTORY FURNISHED HANGING SUPPORTS HANG PER SMACNA BOTTOM OF CONCENTRIC DIFFUSER TO BE HUNG 12'-0" A.F.F. HVAC UNIT MOUNTING DETAIL N.T.S. INSTALLATION INSTRUCTIONS: 1 . SET PURLIN SPAN CHANNEL ASSEMBLY ACROSS PURLINS. POSITION PURLIN SPAN MEMBERS TO ALIGN UNDER THE FLAT OF ROOF PANEL. 2. PLACE CROSS CHANNELS OVER PURLIN SPAN CHANNELS, ADJUST SPACING TO CURB SIZE. 3. AFTER SUPPORT SYSTEM IS IN PLACE, CHECK FRAME OPENING TO CURB I.D. INSERT FOUR ROOF CLIP FASTENERS INTO EACH STIRRUP AS SHOWN ON DRAWING. 4. MANUFACTURER RECOMMENDS INSTALLER PROCEED WITH INSTALLATION OF THE CURB AT THIS TIME. �j REAR CURB FLANGE (SEE DETAIL FOR CUTOUTS) MASTICJ"- TUBE CAULK CUT AT 45°(2) FAN SCHEDULE ELECTRICAL MODEL REMARKS EQUIPMENT AIRFLOW NUMBER FLA TAG LOCATION TYPE (CFM) ESP DRIVE VOLT PHASE WATTS (AM PS) EF-1 GENDER NEUTRAL CEILING 77 0.25 DIRECT 120 1 17.00 0.58 SP-Al 10 RESTROOM 104 FAN EF 2 GENDER NEUTRAL CEILING 77 0.25 DIRECT 120 1 17.00 0.58 SP Al 10 RESTROOM 105 FAN NOTE: 1. ALL MODEL NUMBERS ARE GREENHECK UNLESS OTHERWISE NOTED. 2. PROVIDE GREENHECK MODEL WC WALL CAP, WITH 8"x6" INLET, STEEL FINISH, BACKDRAFT DAMPER AND BIRDSCREEN. GRILLE, REGISTER, DIFFUSER SCHEDULE TAG SERVICE NECK SIZE FRAME SIZE FRAME TYPE ACCESSORIES MATERIAL FINISH MODEL NUMBER REMARKS SD-1 SUPPLY SEE PLANS 12"xl 2" SURFACE MOUNT NONE ALUMINUM WHITE SCD/31 /3C/B12 1,23 SG-1 SUPPLY SEE PLANS 10"X10" SURFACE MOUNT NONE STEEL WHITE 796 4 RG-1 TRANSFER SEE PLANS 18"X16" SURFACE MOUNT NONE ALUMINUM WHITE 796 5 NOTE: 1. MODEL NUMBERS ARE PRICE UNLESS OTHERWISE NOTED. 2. PROVIDE TRANSITION TO DIFFUSER WHERE REQUIRED. 3. PROVIDE GYPSUM BOARD MOUNTING KIT WHERE REQUIRED. 4. PROVIDE RUSKIN GRILLE DUCT TERMINATION CURTAIN TYPE FIRE DAMPER 1 1/2HR RATED. 5. PROVIDE RUSKIN TRANSFER OPENING CURTAIN TYPE FIRE DAMPER 1 1/2HR RATED. DETAIL B t ON THE PLACEMENT OF CROSS CHANNELS, THE OD OF THE OUTSIDE CROSS CHANNELS ARE EQUAL TO, OR FLUSH WITH THE OUTER EDGES OF THE FRONT AND REAR OUTER CURB FLANGES. THE INTERIOR CROSS CHANNEL IS FLUSH WITH THE HIGH SIDE CURB WALL. CROSS CHANNELS ARE TO SUPPORT CURB FLANGE AND ROOF PANEL CONNECTION. 1. NOTCH CURB FLANGE TO ALLOW CURB TO SET IN THE FLAT OF PANEL DRY FIT AND MARK PANEL AT CURB LINE 2. INSTALL MASTIC INSIDE CURB OUTLINE - CUT TAPE AT 45 ANGLE. 3. WHEN INSTALLING CURB, LEADING EDGE OF FRONT FLANGE MUST HAVE UNDER PLUGS PLACED ON MASTIC AND ALIGNED WITH MAJOR RIBS OF ROOF PANEL. MASTIC MUST ALSO BE APPLIED OVER UNDER PLUGS. 4. APPLY TUBE CAULK AROUND PERIMETER, TO THE OUTSIDE OF MASTIC LINE r -UNDER PLUG (3) (SEE DETAIL) TYI)1 RIB CENTERS ZI REAR CURB FLANGE CUTOUT DETAIL UNDER PLUG INSTALLATION DETAIL ` UNDER PLUG ROOF PANEL MASTIC FRONT FLANGE OF CURB CURB INSTALLATION INSTRUCTIONS TRAPEZOIDAL STANDING SEAM PANEL - UNDER / OVER FOLLOW MANUFACTURER'S SPECIFICATIONS REQUIRED NATIONAL ACCOUNT ROOF CURB DG VENDORS: ROOF CURB SYSTEMS GREG SMYTH 800-683-5848 GSMYTH@ROOFCURB.COM CURBS PLUS INC. ALAN THRAILKILL 888-639-2872 ALAN.THRAILKILL@CURBS-PLUS.COM KCC INTERNATIONAL INC. GREG CONRAD 800-382-2872 GCONRAD@KCCCURBS.COM Im SLIT PLATE INSTALLA z MASTIC TUBE CAULK i . a 1 rwi� � wv� vl ROOF PANEL CUTOF TYPICAL ROOF CURB UNIT N.T.S. 1. ATTACH ROOF PANELS 2. ROOF CUTOUT AS FOLLOWS: DIM. A = OVER ALL LENGTH (OAL) - 6 INCHES DIM. W = WIDTH (W) + 1/2 INCH 3. LEADING EDGE OF CURBS FRONT FLANGE IS INSERTED UNDER FRONT EDGE OF ROOF PANEL CUTOUT. SIDE AND REAR FLANGES REST ON TOP OF ROOF PANELS 4. INSTALL TUBE CAULK UP VERTICAL PORTION OF RIB AND OVER TOP OF RIB PRIOR TO INSTALLING ADJACENT PANEL. INSTALL TUBE VGE CAULK IN FIRST FOUR INCHES OF FEMALE RIB TO COMPLETELY SEAL SIDE LAP ABOVE AND BELOW CURB. 3/16"- 1. ATTACH CURB THROUGH ROOF PANEL INTO SUPPORTS WITH SCREWS SPACED AT 3" O.C: 2. APPLY MASTIC & TUBE CAULK TO UNDER SIDE OF RIB CAPS, WITH TUBE CAULK EXPOSED TO THE WEATHER SIDE. ATTACH RIB CAPS WITH FASTENERS 3" O.0 3. GENEROUSLY APPLY TUBE CAULK AROUND PANEL SEAM WHERE IT ENTERS RIB CAP FORCING CAULK BACK INTO TOP OF RB CAP. 4. APPLY MASTIC & TUBE CAULK TO BOTTOM OF SLIT PLATES PRIOR TO INSTALLATION (SEE DETAIL). PLATE (4) SLIT PLATE FALLATION AIL) CONSULTANT: SEAL: HENRY D. MONTAGUE, PE 78172 � N a 1 »`f �x d THIS DRAWING SHALL NOT BE USED FOR CONSTRUCTION PURPOSES UNTIL THE SEAL AND SIGNATURE OF THE RESPONSIBLE REGISTRANT APPEARS ON THE DRAWING, AND PROPER PERMIT FORMS AND RELATED FEES ARE TRANSMITTED BY THE OWNER, OWNER'S AGENT OR CONTRACTOR TO THE AUTHORITY HAVING JURISDICTION. DATE ISSUED FOR REV 09/27/201 8 PEMB COORDINATION 11/27/2018 OWNER REVIEW 12/1 8/201 8 PERMIT SUBMITTAL Project Manager Drawn L. LONG T. PATTERSON Project Leader Checked L. LONG H. MONTAGUE Date Dept Mgr Approval 08/07/2018 H. MONTAGUE Client PALMETTO ZEPHYRHILLS-20th St, LLC P.O. BOX 161 5 THOMASVILLE, GA 31 792 Office: (229) 226-0682 Contact: John Tate Project DOLLAR GENERAL 38965 CR 54 Zephyrhills, FL 33542 (City of Zephyrhills) Store #: 20360 Drawing Title HVAC SCHEDULES, NOTES AND DETAILS DO NOT SCALE DRAWING Project No. Drawing No. JCDT.1 8.0233 M2 NORTH 1 PLUMBING PLAN Scale: 1/8" = V-0" PLUMBING FIXTURE SCHEDULE MARK DESCRIPTION HW CW WASTE VENT REMARKS CONNECTION CONNECTION CONNECTION CONNECTION 20"X18" WALL HUNG ADA LAVATORY W/ FRONT OVERFLOW, CONCEALED HANGERS & 4" CENTERS.AMERICAN STANDARD LUCERNE #0355.012 OR EQUAL. FAUCET SHALL BE POLISHED CHROME -PLATED CAST BRASS BODY WITH 4" SPOUT, 4" BRASS WRIST BLADE, 0.5 LAVA ADA LAVATORY 1/2" 1/2" 2" 1-1/2" GPM SPRAY AND POP-UP DRAIN. AMERICAN STANDARD MONTERREY #5502.175 PROVIDE WATTS MODEL USG-B-M1 ASSE 1070 MIXING VALVE OR EQUAL. INSULATED EXPOSED DRAIN & WATER PIPES WITH TRUEBRO LAV GUARD KIT #102 E-Z. PROVIDE SUPPLIES, STOP VALVES AND P-TRAP. FLOOR MOUNTED ADA VITREOUS. CHINA ELONGATED 1.28 FLUSH GALLON CLOSE COUPLED TWO PIECE SIPHON JET WATER CLOSET, WC-1 ADA WATER CLOSET - 1/2" 4" 2" FLUSH TANK WITH 12" ROUGH -IN. AMERICAN STANDARD CHAMPION 4 "RIGHT HEIGHT" #2002.014 OR EQUAL. PROVIDE STOP VALVE, FLEXIBLE SUPPLY LINE, OPEN FRONT SEAT (AMERICAN STANDARD #5901.100 OR EQUAL). FLOOR MOUNTED ADA VITREOUS CHINA ELONGATED 1.28 FLUSH GALLON CLOSE COUPLED TWO PIECE SIPHON JET WATER CLOSET, ADA WATER CLOSET RIGHT- FLUSH TANK WITH 12" ROUGH -IN. AMERICAN STANDARD CHAMPION 4 "RIGHT HEIGHT" #2002.014 OR EQUAL WITH ALTERNATE TANK WC-2 HAND TRIP LEVER 1/2 4 2 ASSEMBLY #4266.804 (RIGHT HAND TRIP LEVER).. PROVIDE STOP VALVE, FLEXIBLE SUPPLY LINE, OPEN FRONT SEAT (AMERICAN STANDARD #5901.100 OR EQUAL). PROVIDE 10 GALLON ELECTRIC WATER HEATER, 1.65KW @ 120V WITH MANUFACTURER SUPPLIED TEMPERATE AND PRESSURE RELIEF VALVE. (A.O. SMITH #EJC-10, OR EQUAL). PROVIDE THERMAL EXPANSION TANK. (AMTROL THERM-X-TROL ST-12, OR EQUAL). EXPANSION TANK SUPPORT: IT IS THE CONTRACTOR'S RESPONSIBILITY TO PROVIDE ADEQUATE SUPPORT FOR THE EXPANSION TANK. SUPPORT TO ADJACENT WALL ELECTRIC WATER OR FROM EXISTING STRUCTURE ABOVE WITH UNISTRUT. DO NOT SUPPORT FROM PIPE ALONE. EWH-1, 2 HEATER 3/4" 3/4" _ _ PROVIDE DRAIN PAN UNDER WATER HEATERS. PROVIDE SEISMIC STRAPPING ON WATER HEATERS. TERMINATE (EWH-1) DRAIN LINE IN WALL DRAIN BOX. HUB DRAIN (HD-1) TO AND (EWH-2) DRAIN LINE IN MOP SINK (MS-1). PROVIDE FULL SIZE T&P RELIEF LINE, (EWH-1 ONLY) SET WATER HEATER TEMPERATURE AT 110°F MAXIMUM. PROVIDE HOT WATER TEMPERING VALVE SET AT 110°F. REFER TO DETAIL 2/P2. ® (EWH-2 ONLY) REFER TO DETAIL 4/P2 FOR ADDITIONAL INFORMATION. 24" X 24" MOLDED STONE MOP SERVICE BASIN, WITH T DRAIN. FIAT #MSB-2424 OR EQUAL. PROVIDE SERVICE MS-1 MOP SINK 3/4" 3/4" 3" 2" FAUCET WITH PAIL HOOK & INTEGRAL VACUUM BREAKER, MOP BRACKET, FLAT STAINLESS STEEL STRAINER AND HOSE & BRACKET.. FIAT #830 AA, 889 CC, 1453 BB & 832 AA OR EQUAL. PROVIDE SUPPLIES AND P-TRAP. BARRIER FREE ELECTRIC TWO -STATION, WALL MOUNTED, ELECTRIC DRINKING FOUNTAIN, BARRIER -FREE ACCESS (ADA), FRONT ONLY EASY TOUCH CONTROL, EDF-1 DRINKING FOUNTAIN 1/2" - 2" 1-1/2" HIGH UNIT ON RIGHT. ELKAY #EZTLRDDC OR EQUAL. PROVIDE SUPPLY, STOP VALVE & P-TRAP. PROVIDE CANE APRON AS REQUIRED. FREEZE -PROOF WALL HYDRANT WITH BRONZE BODY & ANTI -SIPHON VACUUM BREAKER, BOX AND LOCKING COVER. PROVIDE WITH WHA WALL HYDRANT 3/4" _ _ HOSE CONNECTION AND MOUNT AT 24" ABOVE GRADE. WOODFORD #B65 OR EQUAL. WCO-1 WALL CLEAN -OUT _ _ AS SHOWN ON - SIZE & INSTALL AS SHOWN ON PLANS. JOSAM, ZURN OR EQUAL. PLANS HDA HUB DRAIN 1/2" - 3" 2" PROVIDE 3" PIPE SIZE WITH FUNNEL AND 1 /2"0 TRAP PRIMER CONNECTION. JOSAM, ZURN OR EQUAL. PROVIDE PRESSURE DROP ACTIVATED BRASS TRAP SEAL PRIMER, WITH REMOVABLE FILTER SCREEN. MIFAB #M2-500. NO SUBSTITUTIONS. TP-1 TRAP PRIMER - 1/2" - PROVIDE AIR GAP FITTING. MIFAB #MIGAP. NO SUBSTITUTIONS, PROVIDE DISTRIBUTION UNIT, WHERE TRAP PRIMER SERVES MULTIPLE FLOOR DRAINS, MIFAB #MI-DU-500. NO SUBSTITUTIONS. ECO-1 EXTERIOR CLEAN -OUT - - 4" - PROVIDE TRAFFIC RATED, 2-WAY, EXTERIOR CLEANOUT. TYLER PIPE #003519, OR EQUAL. AS SHOWN ON PROVIDE ADJUSTABLE FLOOR CLEANOUT WITH WATERTIGHT TAPERED THREADED PLUG AND ROUND SCORIATED SECURED TOP, FCO-1 FLOOR CLEAN -OUT _ _ PLANS - ADJUSTABLE TO FINISHED FLOOR. SIZE & INSTALL AS SHOWN ON PLANS. JOSAM, ZURN OR EQUAL. I.E. - 4.00' FOR 0 CIVIL DWGS -ROM LAV, DN TO LAV-1 'ROM EDF-1 0 =ROM LAV, DN TO LAV-1 NOTES: 1. PUBLIC SANITARY SEWER CONNECTION IS REQUIRED. 2. SEPTIC SYSTEM NOT ALLOWED WITHOUT WRITTEN APPROVAL OF DOLLAR GENERAL STORE DESIGN. 3. HOLDING TANK SYSTEMS ARE NOT ALLOWED. 4. LIFT STATIONS ARE NOT ALLOWED WITHOUT DOLLAR GENERAL APPROVAL. 5. CONTRACTOR RESPONSIBLE FOR ALL PUBLIC UTILITY CONNECTIONS (GAS, WATER, ELECTRIC, SEPTIC) AS WELL AS INFRASTRUCTURE REQUIRED BY UTILITY COMPANY. 6. COORDINATE CLEANOUT LOCATION WITH FIXTURE LAYOUT. 7. EWH-1 & EWH-2 REQUIRE PAN DRAIN TERMINATION AND MEANS OF PREVENTING AND CONTROLLING THERMAL EXPANSION. REFER TO 2017 FBC. 1 1/2" V TO 3" VTW. ELBOW DN, COVER OPENING W/ INSECT SCREEN, 1" CW FOR WH-1 SALES AREA 102 W ) MS-1 -2 V DN W ) MS-1 ENLARGED RECEIVING AREA PLAN 1" CW T E ISOLATION VALVE (TYP) ENLARGED RESTROOM PLAN Scale:1/4" = V-0" Scale: 1/4" = V-0" CONSULTANT: SEAL: HENRY D. MONTAGUE, PE 78172 9 izzF THIS DRAWING SHALL NOT BE USED FOR CONSTRUCTION PURPOSES UNTIL THE SEAL AND SIGNATURE OF THE RESPONSIBLE REGISTRANT APPEARS ON THE DRAWING, AND PROPER PERMIT FORMS AND RELATED FEES ARE TRANSMITTED BY THE OWNER, OWNER'S AGENT OR CONTRACTOR TO THE AUTHORITY HAVING JURISDICTION. DATE ISSUED FOR REV 09/27/201 8 PEMB COORDINATION 1 1 /27/201 8 OWNER REVIEW 1 2/1 8/201 8 PERMIT SUBMITTAL Project Manager Drawn L. LONG T. PATTERSON Project Leader Checked L. LONG H. MONTAGUE Date Dept Mgr Approval 08/07/2018 H. MONTAGUE Client PALMETTO ZEPHYRHILLS-20th St, LLC P.O. BOX 1615 THOMASVILLE, GA 31 792 Office: (229) 226-0682 Contact: John Tate Project DOLLAR GENERAL 38965 CR 54 Zephyrhills, FL 33542 (City of Zephyrhills) Store #: 20360 Drawing Title PLUMBING PLANS AND SCHEDULE DO NOT SCALE DRAWING Project No. Drawing No. JCDT.18.0233 P1 VACUUM SHUT-OFF VALVE UNION (TYP.) THERMAL EXPANSION TANK SIZE PER MANUFACTURER'S RECOMMENDATIONS C.W. MAKE-UP MIXING VALVE SPARCO MODEL #102C H.W. TO FIXTURES (110°F) HEAT TRAP TEMPERATURE AND PRESSURE RELIEF VALVE DISCHARGE FULL SIZE OF VALVE DISCHARGE PIPE TO MOPSINK OR FUNNEL DRAIN AND TERMINATE WITH ELBOW TURNED DOWN HB 4" DEEP GALV. DRAIN PAN INSTALL WATER HEATER ABOVE CEILING ON 8" 20 GA. STEEL STUD JOISTS SPACED 8" O,C. SPANNING SURROUNDING WALLS. COORDINATE STRUCTURAL SUPPORT FRAMING WITH G.C. 1" DRAIN LINE. ROUTE TO HUB DRAIN AND TERMINATE WITH ELBOW TURNED DOWN WATER HEATER EWH-1 DETAIL Scale: No Scale SHUT-OFF VALVE C.W. MAKE-UP H.W. TO FIXTURES THERMAL EXPANSION TANK SIZE PER MFG. RECOMMENDATIONS TEMPERATURE AND PRESSURE RELIEF VALVE DISCHARGE FULL SIZE OF VALVE DISCHARGE PIPE TO MOP SINK OR FLOOR DRAIN AND TERMINATE WITH ELBOW TURNED DOWN 1" DRAIN LINE. ROUTE TO MOPSINK OR FLOOR DRAIN AND TERMINATE WITH ELBOW TURNED DOWN PROVIDE AND INSTALL WALL MTD MOP HOLDER SO MOPS ALWAYS DRIP INTO MOP SINK. PROVIDE 2" AIR GAP FOR T&P RELIEF AND DRAIN LINE PIPING RECEIVING AREA FLOOR ALUMINUM CORNER GUARDS ON MOP SINK WING WALL. H WATER HEATER @RECEIVING WATER HEATER "EWH-2" Scale: No Scale VENT 1 SOIL OR WASTE I SEWER VACUUM BREAKER EAT TRAP �1 "CW 3/4"CW 1 /2"CW o e 3/4„ CW o �1 "CW , 1„ CW U/G. FOR CONT. EWH-2 REFER TO 3/4"CW �"� I ,r-3/4"HW a 1 /W CIVIL DWGS. 3/4"CW WC-2 1„CW ____`/ o p1/2"HW S3/4 HW j 1/2"CW EWH-1 0 1/2"CW TRAP r PRIMER 1/2"HWJ TP-1 TO LAV-1 �� HUB 1/2"CW 1 DRAIN WC-1 I 3/4"CW I; �1/2"CW "u W H-1 LAV-1 EDF-1 EWH-1 TO DRAIN INTO HUB DRAIN (HD-1). EWH-2 TO DRAIN INTO MOP SINK (MS-1) REFER TO SHEET P1 FOR ADDITIONAL INFORMATION. COLD & HOT WATER DIAGRAM Scale: No Scale 4" VENT THRU WALL. ELBOW DN AND COVER W/ INSECT SCREEN r. 4' DEEP GALV. DRAIN PAN 2 2" V V I • I INSTALL WATER HEATER ABOVE MOP SINK 2"V AT 7'-6" A.F.F. ON 8" 20 GA. STEEL STUD 2"V A� JOISTS SPACED 8" O.C. SPANNING f' SURROUNDING WALLS. COORDINATE /��.' 1 1/2" V /�' * WC-1 ECO-1 STRUCTURAL SUPPORT FRAMING WITH �� I L. GENERAL CONTRACTOR. 1 1/2" V -A INSTALL FRP @ 48" A.F.F. " 60"WIDE ON THIS WALL. i w� 1 un_�, i , i LAV-1 4SSA \ O r NOTE: CONNECT VENT TO SOIL OR WASTE PIPING SOIL OR ABOVE CENTERLINE. UNDER SLAB HORIZONTAL WASTE CONNECTIONS OF VENT PIPING TO WASTE SEWER SEWER SYSTEM PIPELINE SHALL NOT BE ALLOWED. Scale: No Scale SANITARY & VENT DIAGRAM FLUSH WITH FLOOR LINE-- _..- CLEAN -OUT TO BE TYLER PIPE - - MODEL 003533 SERIES OR EQUAL INSTALLATION SHALL BE FLUSH WITH SURROUNDING FLOOR SURFACES. - t � F _.4 4' Scale: No Scale EXTRA HEAVY DUTY CAST IRON ADJUSTABLE SCORIATED SECURED COVER. BRONZE TAPER THREAD PLUG WITH (COUNTER SUNK HEAD FLANGE WASTE LINE LENGTH TO SUIT FLOW 4„1 IFLOW 4„ , THIS DETAIL USED FOR 4" SANITARY LINE RUN BELOW FIXTURE RACKING. SEE PLANS. 2-WAY YARD CLEAN OUT DETAIL -WAY YARD CLEAN OUT DETAIL Scale: No Scale GENERAL PLUMBING NOTES & SPECIFICATIONS 1. GENERAL NOTES ARE APPLICABLE TO ALL PLUMBING WORKING DRAWINGS. 2. THE WORK SHALL BE EXECUTED IN STRICT CONFORMITY WITH BASE BUILDING SPECIFICATION AND WITH THE LATEST EDITION OF THE PREVAILING LOCAL PLUMBING AND BUILDING CODES AND ALL LOCAL REGULATIONS THAT MAY APPLY. IN CASE OF CONFLICT BETWEEN THE CONTRACT DOCUMENTS AND A GOVERNING CODE OR ORDINANCE THE MORE STRINGENT STANDARD SHALL APPLY, 3. ALL PLUMBING WORK SHALL BE COORDINATED WITH ALL OTHER TRADES BEFORE PROCEEDING WITH INSTALLATION. 4. PLUMBING CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL NECESSARY PERMITS AND FOR PAYING RELATED FEES. 5. ROUGH -IN DIMENSIONS OF TOILET FIXTURES MUST BE COORDINATED WITH GENERAL CONTRACTOR AND FIELD SUPERVISOR. 6. INSTALL BALL VALVES ON ALL BRANCH SUPPLY LINES. 7. PROVIDE ACCESS PANELS ON ALL INACCESSIBLE VALVES AND CLEANOUTS. ACCESS PANELS SHALL BE PROVIDED BY GENERAL CONTRACTOR. PLUMBING CONTRACTOR SHALL BE RESPONSIBLE FOR THEIR LOCATION. MOUNT SHUT-OFF VALVES NO HIGHER THAN 12'-8" AFF. 8. ALL WORK SHALL BE PROPERLY TESTED, BALANCED AND CLEANED. PROVIDE A ONE YEAR WARRANTY FROM DATE OF FINAL INSPECTION ON ALL PARTS AND LABOR.. 9. FOLLOW PDI STANDARDS FOR WATER HAMMER ARRESTORS. 10. ALL FIXTURES TO BE SUPPLIED & INSTALLED BY PLUMBING CONTRACTOR,. 11. GENERAL CONTRACTOR SHALL COORDINATE WATER METER LOCATION AND INSTALLATION WITH LOCAL AUTHORITIES AND CIVIL DRAWINGS. 12. PROVIDE BUILDING SERVICE LINE 5'-0" FROM BUILDING LINE, OR INSIDE BUILDING FROM OUTLET SIDE OF METER AS SHOWN ON CIVIL SITE PLAN. COORDINATE EXACT LOCATION WITH CIVIL DRAWINGS AND AT JOB SITE. IF LOCAL MUNICIPALITIES REQUIRE BACKFLOW PREVENTION DEVICE, A MINIMUM RPZ TYPE SHALL BE PROVIDED. 13. SANITARY SEWER PIPING SHOWN IS BASED ON 0.125"/FT FOR 3"-6" & 0.25"/FT FOR 2 1/2" OR LESS FOR ALL PIPING. COORDINATE BUILDING SEWER LOCATION AND INVERT ELEVATION WITH CIVIL DRAWINGS. 14. TRAP SEAL PRIMERS ARE TO BE PROVIDED AT NO ADDITIONAL COST TO OWNER IF REQUIRED BY LOCAL BUILDING CODE OFFICIALS. 15. VTR'S SHALL BE LOCATED A MINIMUM OF 5' FROM ANY PARAPET WALL AND 10' FROM ANY RTU AIR INTAKE. 16. FURNISH ALL MATERIAL, LABOR, EQUIPMENT, AND ACCESSORIES AS REQUIRED TO INSTALL COMPLETE PLUMBING AND HVAC PIPING SYSTEMS AS INDICATED ON MECHANICAL DRAWINGS AND IN THESE SPECIFICATIONS. 17. SANITARY SEWERS a. INSTALL SANITARY SEWERS, STACKS, VENTS, DRAINS, CLEANOUTS, ETC., AS INDICATED ON THE DRAWINGS. b. SEWERS TO BE PITCHED A MINIMUM OF 1/4" PER FOOT FOR 3" SIZES AND UNDER AND 1/8" PER FOOT FOR 4" SIZES AND LARGER OR TO GRADES INDICATED ON DRAWINGS. c. CHANGES IN DIRECTION AND BRANCH CONNECTIONS SHALL BE MADE WITH APPROVED DRAINAGE FITTINGS COMPATIBLE WITH THE PIPING SYSTEM MATERIAL IN WHICH IT IS INSTALLED. d. ALL FIXTURES AND SANITARY DRAINS SHALL BE VENTED AS INDICATED ON DRAWINGS AND IN ACCORDANCE WITH CODE. e. VENTS ARE TO BE EXTENDED THROUGH WALL IN ACCORDANCE WITH PEMB MANUFACTURER'S DETAILS OR THROUGH ROOF AS INDICATED ON DRAINS AND FLASHED WITH 4 LB. LEAD WITH VENT FLASHING TOP TURNED DOWN TWO (2) INCHES MINIMUM INSIDE PIPE. 18. BELOW GRADE SANITARY INSIDE BUILDING a. SERVICE WEIGHT - PVC AND CPVC ASTM A74-82 WITH ASTM C564-70 NEOPRENE COMPRESSION JOINTS OR NO -HUB b. PVC-DWV PLASTIC ASTM D1785 WITH ASTM D2665 DWV SOLVENT WELD SOCKET FITTINGS. 19. ABOVE GRADE SANITARY SEWER AND VENT a. NO -HUB CAST IRON PIPE CISPI 1-301-78. b. PVC-DWV PLASTIC ASTM D1785 WITH ASTM D2665 DWV SOLVENT WELD SOCKET FITTINGS (IN CONCEALED AREAS ONLY, PVC SHALL NOT BE INSTALLED IN CEILING PLENUMS). c. SCHEDULE 40 GALVANIZED STEEL PIPE, ASTM A53-83 WITH CAST IRON SCREWED FITTINGS ANSI B16.22 1983. 20. DOMESTIC WATER PIPING a. INSTALL DOMESTIC WATER PIPING AS INDICATED ON DRAWINGS. INCLUDE ALL FITTINGS, VALVES, HANGERS AND OTHER ACCESSORIES. EXTEND DOMESTIC WATER PIPING TO ALL FIXTURES AND EQUIPMENT REQUIRED FOR COMPLETE INSTALLATION. b. INCLUDE UNIONS, OR OTHER DISCONNECT MEANS, STOPS OR VALVES FOR ISOLATION OF FIXTURES AND EQUIPMENT. VALVES TO BE FULLY COMPATIBLE WITH PIPING FOR SERVICE INTENDED AS MANUFACTURED BY NIBCO, CRANE OR MILWAUKEE. INCLUDE HOSE OR DRAIN VALVES AT LOW POINTS WHERE FIXTURES CANNOT BE USED FOR DRAINAGE. c. PROVIDE WATER HAMMER ARRESTERS OF TYPE AS INDICATED ON THE DOMESTIC WATER RISER DIAGRAM. THESE SHALL BE ASSE 1010 OR PDI-WH2O1, PISTON TYPE WITH PRESSURIZED METAL -TUBE CUSHIONING CHAMBER AS MANUFACTURED BY SIOUX CHIEF, AMTROL, JOSAM OR ZURN. d. HANGERS ON INSULATED PIPE TO BE OUTSIDE OF INSULATION, SIZED ACCORDINGLY AND WITH A SUFFICIENT SADDLE TO PROTECT INSULATION. 21. DOMESTIC WATER PIPING SHALL BE AS FOLLOWS: a. ABOVE GRADE - TYPE "L" HARD COPPER ASTM B88-832 WITH WROUGHT COPPER FITTINGS ASTM B16.22 1980 AND NON -LEAD OR ANTIMONY SOLDER JOINTS. b. BELOW GRADE - CPVC OR PVC WITHOUT SPLICES OR FITTINGS. c. FLUSH, VENT AND SANITIZE ALL WATER PIPING WITH CHLORINE AS REQUIRED PER AWWA, LOCAL BUILDING DEPARTMENT AND HEALTH DEPARTMENT CODES. d. DOMESTIC HOT AND COLD WATER PIPING UNDER CONCRETE FLOOR TO BE COVERED WITH SAND SO THAT PIPING WILL 3" VENT THRU WALL. NOT BECOME EMBEDDED IN THE FLOOR SLAB. -ELBOW DIN AND COVER e. ALL PIPING UNDER CONCRETE FLOOR SHALL BE CPVC PIPING, CONTINUOUS. NO SPLICES OR FITTINGS WILL BE W/ INSECT SCREEN ALLOWED. f. EXTREME CAUTION MUST BE TAKEN SO THAT NO PIPING AND INSULATION UNDER CONCRETE FLOORS BECOMES CRUSHED, CUT, SPLIT OR DEFORMED DURING THE POURING OF THE FLOOR SLAB. ECO-1 I 1 1/" V WCO-1� 3" SAN MS-1 PROVIDE CLEANOUT WITH ADJUSTABLE CLEANOUT TOP WITH VARIATIONS SUITABLE FOR FLOOR COVERING (CARPET MARKER, RECESSED FOR TILE, SCORIATED FOR UNFINISHED FLOORS). CLEAN THE TOP OF EXPOSED FCO AFTER INSTALLATION. a - .4t 4 /-CLEANOUT PLUG AS SPECIFIED. / APPLY TEFLON JOINT COMPOUND / TO THE CLEANOUT PLUG THREADS FLOOR SLAB ON GRADE SAME SIZE AS SEWER UP TO 4" MAXIMUM MEMBRANE CLAMP l_ I AS REQUIRED FOR LONG SWEEP ELBOW AT DEPTH OF SEWER E END OR TURN OF RUN SANITARY AND/OR — COMBINATION WYE AND STORM SEWER, SIZE EIGHTH BEND IN RUN, PER PLAN REDUCING TYPE IF REQUIRED. �ENTER TOP OF PIPE. DIRECTION OF FLOWS REFER TO SPECIFICATIONS AND SCHEDULE FOR MORE INFORMATION. LOCATE AT BUILDING EXIT, AT ENDS OF RUNS, AT TURNS OF PIPE GREATER THAN 45°, AT 50' INTERVALS ON STRAIGHT RUNS, AND/OR WHERE SHOWN ON PLANS AND RISERS. PROVIDE BACKFILL PER ARCHITECTURAL SPECIFICATIONS. LOCATE CLEANOUT WHERE THERE IS 18" CLEAR AROUND, FOR ACCESSIBILITY. CONSULT LOCAL CODES AND OFFICIALS FOR OTHER REQUIREMENTS. FLOOR CLEAN OUT DETAIL O T DETAIL Scale: No Scale OUTSIDE CORE DRILL WALL FOR EXISTING MASONRY OR CONCRETE CONSTRUCTION INSIDE LEGEND - SS -- - SANITARY SEWER --- - DOMESTIC COLD WATER -- -- DOMESTIC HOT WATER CD CONDENSATE DRAIN ------------ PLUMBING VENT UNION PLUG COCK C - ELBOW - TURNED DOWN �----- ELBOW - TURNED UP -- - TEE - TURNED DOWN ------ TEE -TURNED UP -��-- GATE VALVE --10-- BALL VALVE -\�-- CHECK VALVE SHUT-OFF VALVE IN VERTICAL LINE T & P RELIEF VALVE FCO FLOOR CLEANOUT YCO YARD CLEANOUT -- WH WALL HYDRANT ZWCO WALL CLEANOUT FD FLOOR DRAIN HW HOT WATER DIN DOWN CW COLD WATER VTR VENT THRU ROOF CONT. CONTINUATION U/G UNDER GROUND I.E. INVERT SAN SANITARY SEWER ELEVATION V PLUMBING VENT CD CONDENSATE DRAIN CIRCLE CUT NEW OR EXISTING STUD CONSTRUCTION AND PROVIDE GALVANIZED STEEL PIPE FOR 6" AND SMALLER. PROVIDE 10 GAUGE GALVANIZED SHEET STEEL ROUND TUBE FOR 6" AND LARGER. CAULK SLEEVE IN PROVIDE GALVANIZED STEEL PIPE WITH - PLACE. RETAINING RING TO ANCHOR PIPE AND rf ACT AS A WATER STOP. GROUT IN PLACE l '' _ FOR EXISTING MASONRY OR NEW ± _ PACK ANNULAR SPACE WITH CONCRETE CONSTRUCTION. L yFIBERGLASS INSULATION AND PROVIDE - - - �'WATERPROOF NOW SHRINK SILICONE - SEALANT ON INSIDE AND OUTSIDE r = , PROVIDE CAST IRON WALL PIPE WITH ; FLUSH WITH WALL. RETAINING RING TO ANCHOR PIPE AND ACT AS A WATER STOP. _POUR IN PLACE FOR NEW CONCRETE PROVIDE ESCUTCHEON FOR EXPOSED CONSTRUCTION. PIPE IN FINISHED SPACE NOTE: PIPING ARRANGEMENT SHOWN IN SCHEMATIC. ADJUST TO SUIT FIELD CONDITIONS. REFER TO SPECIFICATIONS FOR MORE INFORMATION ON INSULATION AND SEALANT. COORDINATE SLEEVE INSTALLATION WITH GENERAL CONTRACTOR. 5 PIPING PENETRATION DETAIL Scale: No Scale METAL CUP WITH (3) SHEET METAL SCREWS FASTENED TO BOTH STUDS WATER HEATER SHELF MOUNTED WATER HEATER STRAP TO WALL AS INDICATED. (1) STRAP ON THE UPPER 1/3 & (1) ON THE LOWER 1/3 MAINTAINING A MINIMUM OF 4" FROM CONTROLS. STUD IN WALL �- (2) SHEET METAL OO ® O SCREWS 3/4" WIDE 20 GAUGE STRAP LATERAL SUPPORT WATER HEATER INSTALL WATER HEATER ABOVE M-OP SINK UPON 8" 20 GA. STEEL STUD JOISTS SPACED 8" O.C. SPANNING SURROUNDING WALLS AT 7'-6" A.F.F. AT MOP SINK AND ABOVE CEILING AT HALLWAY. COORDINATE STRUCTURAL SUPPORT FRAMING WITH G.C. Scale: No Scale CONSULTANT: SEAL: HENRY D. MONTAGUE, PE 78172 �I € 4 rtOf THIS DRAWING SHALL NOT BE USED FOR CONSTRUCTION PURPOSES UNTIL THE SEAL AND _ SIGNATURE OF THE RESPONSIBLE REGISTRANT APPEARS ON THE DRAWING, AND PROPER PERMIT FORMS AND RELATED FEES ARE TRANSMITTED BY THE OWNER, OWNER'S AGENT OR CONTRACTOR TO THE AUTHORITY HAVING JURISDICTION. DATE ISSUED FOR REV 09/27/201 8 PEMB COORDINATION 1 1 /27/201 8 OWNER REVIEW 1 2/1 8/201 8 PERMIT SUBMITTAL Project Manager Drawn L. LONG T. PATTERSON Project Leader Checked L. LONG a H. MONTAGUE Date Dept Mgr Approval 08/07/2018 H. MONTAGUE Client PALMETTO ZEPHYRHILLS-20th St, LLC P.O. BOX 1615 THOMASVILLE, GA 31 792 Office: (229) 226-0682 Contact: John Tate Project DOLLAR GENERAL 38965 CR 54 Zephyrhills, FL 33542 (City of Zephyrhills) Store #: 20360 Drawing Title PLUMBING DETAILS AND _DIAGRAMS DO NOT SCALE DRAWING Project No. Drawing No. JCDT.18.0233 P2 BRING RIGID PIPE SLEEVE THROUGH BUILDING TO ALLOW PHONE LINE PENETRATION. SEAL ALL PENETRATIONS. s L 3/4" PLYWOOD 8'-9" WIDE X 5'-5" HIGH, FIRE RATED, NO VOIDS, PAINTED WHITE UNLESS rnnG r)1r1TA-rGc nTLJ=D1n11eC: THROUGH WALL. SEE ELECTRICAL SPECIFICATION NOTE 'E' AND 'H'. LOW VOLTAGE VENDOR TO PROVIDE AND INSTALL ONE (1) 24 GA., 4 TWISTED -PAIR, CATEGORY -FIVE (CAT5) DATA CABLE WITH MODULAR COMBO RJ-11/ RJ 45 JACK AT MANAGERS OFFICE. CABLE TO BE RUN FROM JACK TO DATA HUB LOCATION WITH 6' LEFT COILED FOR INSTALLATION TO DATA HUB. A RJ-45 MALE FITTING SHOULD BE CRIMPED ON THIS END. DOLLAR GENERAL STORE OPENING TEAM WILL MAKE FINAL CONNECTION INTO THE DATA HUB. —� DEDICATED QUAD RECEPTACLE @ 3'-0" FOR CCTV EQUIPMENT DEDICATED QUAD RECEPTACLE @ 3'-0" ELECTRICAL PANEL ELEVATION BUZZER PUSH BUTTON 2 BUZZER, A/4 A/4 E1 =D PROVIDE TOGGLE SWITCH AT WATER HEATER. A/21 RECEIVING AREA 103 f Scale: NTS OFFICE A/26 101 A/24 7 A/22 VS A/18 A/26A/26 IA/28 A/20 sw SECURITY OUTLET AT 7'-0" DEDICATED DUPLEX RECEPTACLE Q48" FOR INTERFACE EQUIPMENT. DEDICATED QUAD RECEPTACLE 6'-0" FOR VSAT AND D—LINK EQUIPMENT ENLARGED OFFICE POWER PLAN SCALE 1/4" = V-O" 5 ) ( 4 ) ( 3 ) ( 2 ) ( 1 TO RTU-1 RTU-1 VERIFY ACTUAL HVAC ELECT. REQUIREMENTS WITH CONTRACTOR. (TYP), GFCI, WP,A/10 3,5 SALES AREA 102 RTU-2 9 SO CORD (WHITE). ANCHOR TO PURLINS ABOVE. REFER TO ARCHITECTURAL PLANS FOR DIMENSIONS. (TYPICAL ' B/36 10 TO RTU-2 O O GFCI, WP,A/10 A/7,9,11 REFER TO REGISTER POWER POLE SO44 DETAIL 3/E4. B/2,4,6,8,10,12. *B/36 6/36 00 1- N * N cM O Imo. r LOco m Cl m . ...Q61-711 61-711 61-711 61-7 61—Ire 5-7 4'-7.9 -0n POWER PLAN Scale: 1/8" = V-0" RESTROOM EXHAUST FAN. CONNECT TO ROOM SENSOR LIGHT CONTROL SWITCH. RESTROOM EXHAUST FAN. CONNECT TO ROOM SENSOI LIGHT CONTROL SWITCH. A/32 00 co 61-011 Q A/12 AUTOMATIC DOOR A/2 B/21 GFCI A/23 B/21 A/28 Psw A/30 I I VS s A/2$ A/30 A/28 A/30 LEGEND BUZZER - TORK MDL #TA725 W/ TRANSFORMER MDL#TA592 ❑� PUSH BUTTON 125V NEMA 5-20R DUPLEX. A/23 PANEL/CIRCUIT IN PANEL (sw 125V NEMA 5-20R DUPLEX. A/28 SPLIT WIRED. A/30 PANEL/CIRCUIT IN PANEL 1251250V NEMA L14-20-R 4 PRONG TWIST LOCK 125V NEMA 5-20R QUAD. VACANCY SENSOR: GREENGATE DUAL TECH LOW VOLTAGE #VAC-DT-0501-R OR EQUAL. PROVIDE WITH SWITCH PACK. Q TEMPERATURE SENSOR: BY MECHANICAL LEI DISCONNECT BLACK MAGIC POWER POLE PHONE JACK @ REGISTER O VOICE/DATA PORT = RJ-11, RJ-45 DATA JACK, PHONE COMBO @ OFFICE A/23 PANEL/CIRCUIT IN PANEL MOTION SENSOR SWITCH. m LEVITON #EZ-FIND-ODS-10-IDW 20 AMP TOGGLE SWITCH NIL NIGHT LIGHT CIRCUIT OFFICE -1 00A/36 101 J GENDER NEUTRAL 104 PROVIDE TOGGLE SWITCH AT RESTROOM WATER HEATER. A/19 GENDER NEUTRAL 105 DEDICATED GFCI,WP, 20AMP OUTLET RECESSED @ 4' A.F.F. FOR ICE MERCHANDISER, BREAKROOM 100 3 E1 NOTE: IF STORE IS LABELED "RELOCATED", PROVIDE J BOX OVER ENTRY DOORS FOR CCTV, ELECTRICAL SPECIFICATIONS A. ALL WIRING SHALL BE CONTAINED IN CONDUIT OF PROPER SIZE. B. ALL WIRING SHALL CONFORM TO LOCAL, STATE, AND FEDERAL CODES. C. SERVICE IS TO BE MINIMUM 4QO AMP, 3 PHASE (PREFERRED) 600 AMP 1 PHASE OR LARGER IF REQUIRED BY CODE OR ELECTRICAL LOAD. D. REQUIRED CUSTOM BUILT POWER POLE ASSEMBLIES AVAILABLE FROM D&P CUSTOM LIGHTS & PRODUCTS INC. PHONE: (800) 251-2200 OR (615) 350-7800, 7111 COCKRILL BEND INDUSTRIAL ROAD, NASHVILLE, TN 37209. SEE SHEET E3. E. EXTERIOR EXPOSED PHONE LINES TO BE INSTALLED IN RIDGED CONDUIT. PROVIDE EMERSON 3/41, X 5-FT. METALLIC CABLE U-GUARD #755, OR EQUAL. F. ELECTRICAL PANELS TO BE LABELED CORRECTLY AND WITH LEGIBLE PRINT. G. PHONE LINES - TWO R -11 PORTS. ONE 1 LOCATED IN OFFICE W R -45 DATA A _ JACK COMBO AND ONE (1) AT REGISTER. 24 GA. CAT 5, 4-PAIR TWISTED WIRE ONLY. USE BLUE AND BLUE & WHITE WIRES. HOOK TO LINE #1 TERMINAL IN RJ-11 JACK EACH PHONE JACK TO HAVE DEDICATED, SEPARATE HOME RUN TO DMARC. LABEL AS "PHONE" AT THE DESTINATION AND AT DMARC. PHONE COMPANY PROVIDES FINAL HOOK UP TO DMARC ONLY, PHONE JACKS ARE SUPPLIED AND WIRED BY CONTRACTOR. H. PROVIDE 1 1/2" EMT CONDUIT TO ACT AS ACCESS SLEEVE TO ALLOW PHONE COMPANY TO TERMINATE AT DMARC, CONTRACTOR TO PROVIDE & INSTALL PHONE WIRING & RJ-11 PHONE JACK FOR A COMPLETED WORKING SYSTEM PRIOR TO PHONE COMPANY FINAL HOOK-UP. I, ALL 120 VOLT OUTDOOR RECEPTACLES TO HAVE "WET LOCATION - IN USE" COVERS. J. ALL CONDUCTORS TO BE COPPER, #12 AWG MINIMUM SIZE, OR SIZE AS REQUIRED BY LOAD AND OVER CURRENT PROTECTION. K. SEE EMS SHEETS EMS1 AND EMS2 FOR ENERGY MANAGEMENT SYMBOLS AND INFORMATION. L. ELECTRICIAN TO PROVIDE %" CONDUIT WITH PULL STRING FOR SATELLITE LINE. REFER TO 3/A3 AND 1/S1 FOR LOCATION. M. ALL POWER AND DATA TO BE ROUTED OVERHEAD. UNDER SLAB IS NOT ALLOWED. N. WIRE SIZE O BE #8 OR #10 AS REQUIRED FOR COOLERS/FREEZERS. O. MOUNT ALL REFRIGERATOR OUTLETS AT 12" AFF. P. WIRE SIZES SHALL BE BASED ON THE 60 DEGREE CELSIUS AMPACITIES FOR WIRE SIZES #14 THRU #1 AWG AND 75 DEGREES CELSIUS FOR WIRE SIZES #1/0 AND LARGER. Q. BRANCH CIRCUIT WIRE SIZES AND CONDUITS SHALL BE INCREASED FROM THOSE INDICATED ON THE PLANS AS REQUIRED TO PREVENT EXCESS VOLTAGE DROP. BRANCH CIRCUITS SHALL BE INSTALLED WITH WIRES OF SUFFICIENT SIZE SO THAT THE VOLTAGE DROP BETWEEN THE PANEL AND THE LOAD DOES NOT EXCEED 3% TO MEET FLORIDA'S BUILDING CODE, ENERGY CODE PART C405.7. ELECTRICAL KEYED NOTES TEST/RESET STATION FOR STAND ALONE DUCT DETECTOR.. ONE FOR EACH DEVICE. SEE KEY NOTE 2 ON THIS SHEET. SIMPLEX #4098-9842 IS SPECIFIED WITH PIEZO AND LED INDICATOR. 0 LOCATION SHOWN FOR MECHANICAL UNITS ARE ONLY APPROXIMATE. CONTRACTOR SHALL CONSULT MECHANICAL AND STRUCTURAL DRAWINGS TO DETERMINE ACTUAL UNIT LOCATIONS. PROVIDE 1/2" PENETRATION THRU ROOF WITHIN FOOTPRINT OF UNIT FOR USE WITH CONTROL WIRING TO UNIT BY OTHERS.. PROVIDE PROPER WATERSEAL (TYPICAL). O FACTORY MOUNTED POWERED CONVENIENCE OUTLET. FIELD VERIFY THAT OUTLET IS POWERED. PROVIDE WP, GFCI RECEPTACLE AT ALL UNITS AND WIRE TO BREAKER IN PANEL "A" IF THEY ARE NOT FACTORY PROVIDED. 4 PHOTOELECTRIC DUCT DETECTOR WITH HOUSING. TIE TO LED READOUT RECESSED IN DUCT STAND ALONE DEVICE, 120V. SIMPLEX #4098-9687 IS SPECIFIED WITH 4098-9842 CONTROL STATION. PROVIDE ONE DEVICE PER UNIT. MOUNT DEVICE IN SUPPLY AIR DUCTWORK. DEVICE SHALL BE PROVIDED AND WIRED TO THE CONTROL STATION BY THE ELECTRICAL CONTRACTOR. HIRE THE MECHANICAL CONTRACTOR FOR INSTALLATION IN DUCTWORK AND CONNNECTION TO SHUT DOWN CONTROLS. ELECTRICAL CONTRACTOR SHALL PROVIDE ALL REQUIRED RELAYS AND 120V POWER. DO NOT POWER DUCT DETECTORS FROM HVAC LOW VOLTAGE. SUBMIT SHOP DRAWINGS FOR APPROVAL. PLACE ANY REQUIRED LABELING ON CEILING TILE DIRECTLY BELOW UNIT. <g> MOUNT DISCONNECT SWITCH AT UNIT. ALL DISCONNECTS SHALL BE HEAVY DUTY.FUSES TO BE TYPE RK-5 TYPE. BUSSMAN FRN-R-(AMP) FUSES ARE SPECIFIED. g> MECHANICAL THERMOSTAT AT 8'-0" AFF. <' > VACANCY SENSOR. SENSOR SHALL CONTROL LIGHTS AND TOP HALF OF THE DUPLEX RECEPTACLES INDICATED AS SPLIT WIRED, (A/28). <g> SPLIT WIRED RECEPTACLES. CIRCUIT A/30 SHALL BE 'ALWAYS ON', CIRCUIT A/28 SHALL BE CONTROLLED BY THE VACANCY SENSOR. RECEPTACLE SECTIONS THAT ARE AUTOMATICALLY CONTROLLED SHALL BE PERMANENTLY MARKED PER ASHRAE STANDARDS. SO WHITE ELECTRICAL CORD IS REQUIRED. SEE SHEET Al, NOTE 25 AND 25A. CONFIRM THE FINAL NUMBER AND LOCATION OF OUTLETS IN THE SALES AREA WITH THE FINAL DOLLAR GENERAL FIXTURE PLAN. CONSULTANT: SEAL: SEAN PATRICK PIC-KELL, PE 83946 THIS DRAWING SHALL NOT BE USED FOR CONSTRUCTION PURPOSES UNTIL THE SEAL AND SIGNATURE OF THE RESPONSIBLE REGISTRANT APPEARS ON THE DRAWING, AND PROPER PERMIT FORMS AND RELATED FEES ARE TRANSMITTED BY THE OWNER, OWNER'S AGENT OR CONTRACTOR TO THE AUTHORITY HAVING JURISDICTION. DATE ISSUED FOR REV 09/27/2018 PEMB COORDINATION 11/27/2018 OWNER REVIEW 12/1 8/201 8 PERMIT SUBMITTAL Project Manager Drawn L. LONG G. COLLINS Project Leader Checked L. LONG M. GOOD Date Dept Mgr Approval 08/07/2018 M. GOOD Client PALMETTO ZEPHYRHILLS-20th St, LLC P.O. BOX 1615 THOMASVILLE, GA 31 792 Office: (229) 226-0682 Contact: John Tate Project DOLLAR GENERAL 38965 CR 54 Zephyrhills, FL 33542 (City of Zephyrhills) Store #: 20360 Drawing Title POWER PLAN DO NOT SCALE DRAWING Project No. Drawing No. JCDT.18.0233 E1 9 E B/3 OB- rA AD M 1 AD IN 19 B/3 A NL A E B/19 A /,1 —1j B/19 E G B/33 E 51 G B/33 A ­0 I_1 I A A A A A A -e- j A A NOTE: ALL INTERIOR LIGHTS CIRCUIT TO PANEL B A A NL A A SALES AREA i A 102 ; A A i SALES FLOOR A 11 B/19 A E �A A A A A 4 F1 B/15 \ A G B/33 J � , A B/9 LA LIGHTING PLAN Standard Line Voltage Switch Black (Hot) % z 120V J- - - - - - - - - - - - - - - - - - - Neutral (White) 1 T Black Black White To LED L— White To LED Dimming Dimming Violet (+) Driver Lamps Violet (+) Driver Lamps Gray (-) Gray (-) iu CONTROL SENSOR CMR A C CONTROL NOTES: - EC SHOULD BEJJSING A VIOLET AND GRAY TWO WIRE CABLE AS LIBERTY CABLE #18-2C-LVBP-WHT. - REF INSTALLATION MANUAL TO RUN AUTO SET -POINT FEATURE: FUNCTION 4, OPTION 4. - EC IS RESPONSIBLE FOR NO CROSS WIRING AT ANY POINT IN THE SERIES OF CONNECTIONS. DIMMING CONTROL SENSOR 2 WIRING DIAGRAM Scale: NTS WL I_1 G B/33 re JB A F-1 I HB B/35 GENDER NEUTRAL 104 GENDER NEUTRAL 105 BREAKROOM 100 ,>C= LJ I I OFFICE L B/1 101 -"' 9 I A B/11 A A EMERGENCY/EXIT SIGNS AND LIGHTS: INSTALL EMERGENCY I LIGHTS AND EXIT SIGNS - (CENTERED AT 10'-6" AFF TO BE ABOVE FIXTURES & B/1 MERCHANDISE) THROUGHOUT I THE BUILDING IN COMPLIANCE A A ,1 Al J WITH ALL APPLICABLE CODES. B/19 B/351 t.._. � HB B/35 Al B/23 W _ _. _ _ — — __ JF CONDUIT CONNECTION BETWEEN RACEWAYS J PROVIDED BY THE SIGN 1" PVC SCH 40 HB INSTALLER. HB UNDER GRADE TO B/33 B/41 SITE LIGHTING. B/29, 31 J COORDINATE BUILDING SIGN REQUIREMENTS WITH DOLLAR GENERAL SIGN DEPARTMENT BY EMAILING TO SIGNAGE@DOLLAR ENERAL.COM. 1" PVC SCH 40 REFER TO KEY NOTE Q>. UNDER GRADE TO PYLON SIGN. B/25 Scale: 1/8" = V-0" <�> ELECTRICAL KEYED NOTES 1. OCCUPANCY SENSOR. SENSOR SHALL REDUCE LIGHT LEVEL TO 50% IN THE RECEIVING AREA WHEN THE AREA IS NOT OCCUPIED. REFER TO LEGEND ON SHEET E1 FOR MANUFACTUR'S MODEL NUMBER. 2. CONNECT LIGHT TO VACANCY SENSOR. REFER TO LEGEND ON SHEET E1 FOR MANUFACTUR'S MODEL NUMBER. 3. 'DOLLAR GENERAL' LETTERS MOUNTED ON THE SIDE OF THE BUILDING. ELECTRICAL CONTRACTOR TO VERIFY WITH THE SIGNAGE CONTRACTOR THE EXACT SPOT FOR THE J-BOX AND 120V CONNECTION POINT. THE SIGNAGE CONTRACTOR SHALL INSTALL THE RACEWAYS AND LETTERS AND MAKE ALL CONNECTIONS FROM THE LETTERS TO THE RACEWAYS. LEDS LIGHT FIXTURE SCHEDULE SYMBOL TYPE MANE. PART # DESCRIPTION W COUNT 4' LED FIXTURE. 0 A ETI 54583161 AERIAL MOUNT INCLUDES 33 69 (2) 8 FT CABLES 4' LED FIXTURE. A-NL ETI 54583361 AERIAL MOUNT INCLUDES 33 3 (2) 8 FT CABLES. BBU COMPATIBLE. 25W BBU LED DRIVER _ A-NL-D ETI 90600143 FOR THE SALES AREA -- 1 NIGHT LIGHTS. 4' LED FIXTURE WITH 0 AD ETI 54573341 DIMMABLE DRIVER. 33 3 AERIAL MOUNT INCLUDES (2) 8 FT CABLES SAME AS TYPE 'AD' AD-NL ETI 54573341 EXCEPT CONNECTED TO 33 1 THE NIGHT LIGHT CIRCUIT 0 Al ETI 54583261 4' LED FIXTURE. 33 3 SURFACE MOUNTED. 4' LED FIXTURE WITH 0 AD1 ETI 54573161 DIMMABLE DRIVER. 33 0 SURFACE MOUNTED. o B ETI 54260161 2' LED FIXTURE. 20 2 SURFACE MOUNTED. C ETI 55301101 LED EXIT SIGN -- 1 LED EXIT SIGN / D ETI 55502201 EMERGENCY LIGHT -- 2 COMBO WITH (2) HEADS LED EMERGENCY LIGHT E ETI 55501101 WITH (2) HEADS -- 8 LED EMERGENCY LIGHT E2 ETI 55501201 WITH (2) HEADS AND - 0 REMOTE CAPABILITY LED EGRESS EMERGENCY F ETI 55503101 LIGHT WITH (1) HEAD -- 0 LED EGRESS EMERGENCY F2 ETI 55503201 LIGHT WITH (2) HEADS - 3 LHSWP-1-C-4-T3-F1- LED WALL PACK WITH G TECHLIGHT SWP-W -BZ MOTION SENSOR 38 6 LED AREA LIGHT ON WALL HB TECHLIGHT LSBT-1-C-X-T3-F-1- MOUNT 42" EXTENSION 147 4 n TLWS FSP-21 1 -BZ ARM AND BASEPLATE �L_JI MOUNTED ON WMUPS42 W/ DIMMABLE LED DRIVER, ARM AND WMUPS42PLT PASSIVE INFRARED BASEPLATE MOTION SENSOR, NOTES: 1) REFER TO SHEET701' FOR NATIONAL ACCOUNT VENDORS LIST. 2) PROVIDE DIMMABLE FIXTURES WHERE REQUIRED. CONSULTANT: SEAL: SEAN PATRICK PIC-KELL, PE 83946 W iM11rr1r H0.63946 STATSOF �rrrrrrntt+t'� THIS DRAWING SHALL NOT BE USED FOR CONSTRUCTION PURPOSES UNTIL THE SEAL AND SIGNATURE OF THE RESPONSIBLE REGISTRANT APPEARS ON THE DRAWING, AND PROPER PERMIT FORMS AND RELATED FEES ARE TRANSMITTED BY THE OWNER, OWNER'S AGENT OR CONTRACTOR TO THE AUTHORITY HAVING JURISDICTION. DATE ISSUED FOR REV 09/27/201 8 PEMB COORDINATION 1 1 /27/2018 OWNER REVIEW 12/18/2018 PERMIT SUBMITTAL Project Manager Drawn L. LONG G. COLLINS Project Leader Checked L. LONG M. GOOD Date Dept Mgr Approval 08/07/2018 M. GOOD Client PALMETTO ZEPHYRHILLS-20th St, LLC P.O. BOX 161 S THOMASVILLE, GA 31 792 Office: (229) 226-0682 Contact: John Tate Project DOLLAR GENERAL 38965 CR 54 Zephyrhills, FL 33542 (City of Zephyrhills) Store #: 20360 Drawing Title LIGHTING PLAN DO NOT SCALE DRAWING Project No. Drawing No. JCDT.1 8.0233 E2 F 9 186" 2" 1 FS5-IG 4" @01 1 FS5-IG 4" oog t 1 FS4 4" 1 1 FS4 MODULAR POWER POLE FOR S200-B COUNTER INSTALL (4) IG CIRCUITS 20A 120VAC, (4) NORMAL CIRCUITS 20A 120VAC 12'-6", 13'-6", 14'-6", 15'-6" VERSIONS, ALL WITH 4" DATA ACCESS AT BOTTOM 3 CH POLE POWDER COAT BLACK 182" 1 D5-IG 1 D5-1G 4 1D4 T D1'-0° 1 D4 a - 10,. BLOCKER INSET 2" 1-4 1 5" 3/4' HOLE THRU ALL 1" UP WITH GROMMET FOR DATA CABLE DATA COVER AND ADD -ON DATA CHANNEL STOP 4" SHORT OF BOTTOM FOR DATA PULL ACCESS NO SHARP EDGES Scale: NTS 5" 186" TRIM KIT 4 1/2" 1 1/4" 2 3/8" J 1/8" 1 1/4" 0 01 /4" POWER POLE STRAP - ALL POWER POLES SHALL BE BLACK - ALL WHIPS SHALL BE 10' RED=HOT - CIRCUIT 2 BLACK=HOT - CIRCUIT 1 WHITE=NEUTRAL GREEN=GROUND GREEN/YELLOW=ISOLATED GROUND *NOTE: BEFORE ORDERING AND INSTALLATION OF ELECTRICAL COMPONENTS FOR REGISTERS, CONSULT FINAL FIXTURE PLAN FOR NUMBER AND LOCATION. MAXIMUM CIRCUITS FOR REGISTERS - CIRCUITS AT MAIN REGISTER - (9) 120V CIRCUITS AT ISLAND REGISTER - (3) 120V GREEN=SHIELD GROUND WHITE=NEUTRAL- BLACK=HOT - CIRCUIT 1- RED=HOT - CIRCUIT 2 BLACK=HOT - CIRCUIT 1 WHITE=NEUTRAL GREEN=SHIELD GROUND 747DGS023B GREEN/YELLOW=ISOLATED GROUND RED=HOT - CIRCUIT 2 REGISTER ELECTRICAL COMPONENTS Qty. D&P Part No. Power Pole Description National Account Provider 1 747DGS023B Dual circuit power kit with isolated ground D & P 1 747DGS023R Dual circuit power kit D & P 1 747DGSO44-126BK 12' 2-CH regular pole w/2-C and 1-D connector DRW #2004-12 1 747DGS032A 10' Cable kit (Set of 4 whips) REGISTER ELECTRICAL DETAIL Scale: NTS UJ J m DMARC PHONE WIRING FOR REGISTER Scale: NTS 1 D5-1G GREEN 1 D5-IG GREEN 1 D4 BROWN CONSULTANT: SEAL: SEAN PATRICK PIC-KELL, PE 83946 f w TAT E O F ; ,�� 26� ..- 1riftiitEl'100� THIS DRAWING SHALL NOT BE USED FOR CONSTRUCTION PURPOSES UNTIL THE SEAL AND SIGNATURE OF THE RESPONSIBLE REGISTRANT APPEARS ON THE DRAWING, AND PROPER PERMIT FORMS AND RELATED FEES ARE TRANSMITTED BY THE OWNER, OWNER'S AGENT OR CONTRACTOR TO THE AUTHORITY HAVING JURISDICTION. DATE ISSUED FOR REV 09/27/201 8 PEMB COORDINATION 1 1 /27/201 8 OWNER REVIEW 12/18/2018 PERMIT SUBMITTAL Project Manager Drawn L. LONG G. COLLINS Project Leader Checked L. LONG M. GOOD Date Dept Mgr Approval 08/07/2018 M. GOOD Client PALMETTO ZEPHYRHILLS-20th St, LLC P.O. BOX 1615 THOMASVILLE, GA 31 792 Office: (229) 226-0682 Contact: John Tate Project DOLLAR GENERAL 38965 CR 54 Zephyrhills, FL 33542 (City of Zephyrhills) Store #: 20360 Drawing Title POWER POLE AND POWER TERMINAL DETAILS DO NOT SCALE DRAWING Project No. Drawing No. JCDT.18.02 3 3 E3 ,V, ELECTRICAL DMARC AND E PANELS IN RECEIVING ARE CONDUIT #1: PROVIDE 1-1/, CONDUIT TO CABLE TRAY. LOW VOLTAGE CABLE TRAY PLAN SCALE : 1/8" 1= V-0" NOTES: 0 1) CABLE TRAY SHALL BE MOUNTED SUCH THAT THE BOTTOM OF THE TRAY IS AT 1 V-6" AFF. 2) CABLE TRAY SYSTEM SHALL BE INSTALLED USING FULL LENGTH SECTIONS WITH MINIMAL CUTTING OF SECTIONS. 3) BOTTOM OF CABLE TRAY SHALL BE WHITE CONSULTANT: SEAL: SEAN PATRICK PIC-KELL, PE 83946 ����ttflii#tt/1ll t` �1j'ilitilit _I THIS DRAWING SHALL NOT BE USED FOR CONSTRUCTION PURPOSES UNTIL THE SEAL AND SIGNATURE OF THE RESPONSIBLE REGISTRANT APPEARS ON THE DRAWING, AND PROPER PERMIT FORMS AND RELATED FEES ARE TRANSMITTED BY THE OWNER, OWNER'S AGENT OR CONTRACTOR TO THE AUTHORITY HAVING JURISDICTION. DATE ISSUED FOR REV 09/27/201 8 PEMB COORDINATION 1 1 /27/201 8 OWNER REVIEW 12/18/201 8 PERMIT SUBMITTAL Project Manager Drawn L. LONG G. COLLINS Project Leader Checked L. LONG M. GOOD Date Dept Mgr Approval 08/07/2018 M. GOOD Client PALMETTO ZEPHYRHILLS-20th St, LLC P.O, BOX 1615 THOMASVILLE, GA 31 792 Office: (229) 226-0682 Contact: John Tate Project DOLLAR GENERAL 38965 CR 54 Zephyrhills, FL 33542 (City of Zephyrhills) Store #: 20360 Drawing Title CABLE TRAY LAYOUT PLAN DO NOT SCALE DRAWING Project No. Drawing No. JCDT.1 8.0233 E4 V a w MOUNT: SURFACE' 120/208 3-PHASE, 4W PANEL A, CAPACITY: 400A INT OAP: 22KA a LOCATION: BACK OF BLDG. LUGS: MLO DEMAND LOAD: 291A AV. FAULT: 12 KA Q CKT LTG REC HVAC M#SC', NP- DESCRIPTION AMP POLE AMP POLE DESCRIPTION LTD REC HVAD ItISC NP CKT I 91.0 RTU 1 100 3 A 20 1 AUTOMATIC DOOR 0.1 2 11.0'' B 20 1 PHONE BOARDIBUZZER OA 4 C 6 11.0 C 20 1' ENERGY MANAGEMENT 0.2 6 C 7 11.0 RTU 2 100A 3 A 20 1 SPARE 8 9 1 1 11.0 1 B 20 1' OUTDOOR HVAC REC 0.7 10 11 11.0 C 20 1 OUTDOOR DRINK VEND 0.2 12 13, SPARE 20 1' A 20 1 SPARE' . 14 15 SPARE 20 1 B 20 1 SPARE is 17 SPARE' 20 1 C 20 1 INTERFACE EQUIP 0.5 1' 8 C 1 19 1 1 1.7 WATER HEATER#1 20 1 A 20 1 VSATSATA HUB EQUIP 0.5 20 C 21 1.7' WATER HEATER #2 20 1 B 20 1': CCTV EQUIP 1.0 22 23 0.2 DRINKING FOUNTAIN 20 1, C 20 1' SECURITY REC 0.2 24 C 25 0.2 OUTDOOR ICE REC 20 1 A 20 1 OFFICE REC 6.7 26 C C 27 1.2 COOLER #1 20 1 B 20 1 BREAK ROOM REC 0,5 28 C 29 1.2 COOLER #2, 20 1 C 20 1 OFFIBREAKRM RECEPT 0.6 30 C 31 1,2 COOLER#3 20 1'; A 20 1' BEAUTYICOSME11CSS 0.4' 32 C 33 1.2 COOLER #4 20 1 B 20 1 ICE CREAM FREEZER 0.8 34 C C 36 1.6 COOLER #5 20 1 C 20 1 GATORADE RECEPT 0.2 36 C 37 SPARE 20 1 A 200 3 PANEL B 38 39 J SPARE 20 1 1 1 B 14-2 0.0 0.1 20.8 0.0 40= 41 SPARE 201 11 1C 42 PHASE BALANCE LOAD TYPE CONNECTED DEMAND DEMAND FORMULA TOTAL LOAD LIGHTING 11.2 KVA 14:0 KVA LOAD X 125% NEC210.19 CONTINUOUS CONNECTED DEMAND 6 LOAD % RECEPTACLE 4.5 KVA 4.5 KVA 10KVrA + 50°/6 REMAINDER NEC 220.44 115.3 KVA 104-'SK A A 26.8 KVA 23% HVAC 6 6. 1 KVA 52 2 KVA LOAD X 811% (USED MCA 1N CALCULATION) 320.0A 291.1 A B 61.6 KVA 53% MISC 33,5 KVA 33.5 KVA LOAD X 100% NEC 210-19 NON-CONT. FILENAME C 26.9 KVA 23% NP 0.0 KVA 0.0 KVA 0 NONCOINCiDENTAL LOADS NEC' 220.60 DG Zeph rhi0s_FL Panel Sc NOTES. A. AIC RATING: SERIES RATED AT 200,000 AMPS WITH BUSSM ANN JJN FUSES. B. BREAKERS FOR HVAC UNITS SHALL BE SIZED PER MANUFACTURER REQUIREMENTS. G. BREAKER LOCK. D. ISOLATED GROUND BUS. EQUIPMENT SCHEDULE PLAN EQUIPMENT LOAD VOLT/ FED DISC MCA ;MOCPD FEEDER; REMARKS MARK SERVED PHASE BY BY RTU 1 ROOF TOP UNIT 33.10KVA 20813 A EC 92.OA 100A (3)#3,#10G 1 114 "C' PROVIDE1100A/3P'NIF DISCONNECT RTU 2 ROOF TOP UNIT 33A0KVA 20813 A EC 92.0A 100A (3)#3, #10 ,,1 114 "Cl PROVIDE 10OA13P NI` DISCONNECT FILENAME: DG Zephyrhills FL Panel Schedules.xls 5C3L# CE [IRE bRCABLE LOAD �208V ,,,,,, � .a�r. Win„ 5f0IVlCM i30�280AI ,�.. 31'0 12.OI208 3-PHASE, 411U PANEL i LOAd CAPACITY: 400A This Should b the Ilne-to-line these are uncu t copper or aluminum - voltage for multi voltage and tond�€ctar sizes with CU/AL HOC a`frrspac�tY i Load current an amperes LOAD TYPE CONNECTED DEMAND DEMAND FORMULA TOTAL LOAD 3.,pirase systsrrss, Fora 120/240V single phase system listed at 3Et� arnhlent rot rePerets. LIGHTING 11.2 KVA 14.0 KVA LOAD 1251/6 NEC 210.19 CONTINUOUS CONNECTED DEMAND select 24CiU< For other single phase systems select She direr- � .,,.,,.�..N�..�.�,- alumsnurn conductor � F _ - � ---, RECEPTACLE 4.5 KVA 4..5, KVA 10KVA + 50%`REMAINDER NEC 22 0 A4 115.3 KVA 104.9KVA to -neutral voltage. . � ,m ib 07 ). A HVAC 66.1 KVA 52.9 KVA LOAD X 80l (USED MCA IN CALCULATION) 320,0A 291.1A - AC: 3 phase 60Hz .,...�� _. ,..,,,tip. ,.� �,� , NEC tables assume oparatlra, MISC` 33.5 KVA 33.5 KVA LOAD X 100,% I NEC 210.19 NON-CO'NT: FILENAME temperature. it conductor is oversized a lower temperature can be used but this NP 0.0 KVA 0.0 KVA 0 NONCOINCIDENTAL LOADS NEC 220.60' DGZe h r ills FL Panel Sc P temperature should always be higher than - ambient, This value only used for adjusting conductor resistance. 400A DISCONNECT: PROVIDE 600V/3P, 400A/400A BUSSMANN JJN FUSES IN MAIN HEAVY DUTY SERVICE DISCONNECT SWITCH. COORDINATE LOCATION WITH UTILITY COMPANY AND DOLLAR GENERAL. AVAILABLE SHORT CIRCUIT (TYPICAL) 9,753 (2) SETS OF (4)#3/0 CU, 2-1/2"C ­� CT'S/ METER CABINET PER UTILITY COMPANY REQUIREMENTS (3) SETS OF (4)#500, AL, 3"C UNDERGROUND SERVICE ENTRANCE PER UTILITY AND SITE SPECIFIC CONDITIONS. REFER TO SHEET ES1 FOR LOCAL UTILITY CO. POLE/TRANSFORMER LOCATION. G.C. SHALL COORDINATE WITH CIVIL FOR THE EXACT LOCATION OF THE POLE MOUNTED TRANSFORMERS AND MAKE ANY CHANGES TO THE SERVICE ENTRANCE WIRING SIZE IF THE CONNECTION POINT IS DIFFERENT THAN WHAT IS SHOWN. NOTE: REFER TO THE ELECTRICAL SPECIFICATIONS ON SHEET E1 FOR CONDUCTOR TYPES AND INSULATION. 1/0 SYSTEM GROUND, SEE DETAIL #2/E6 EXTERIOR (4)#3/0 CU, #6G, #61G, 2-1/2"C A B N 9,311 - N G G IG IG (2) SETS OF (4)#3/0 CU, #3G, #31G, EACH IN 3"C INTERIOR ELECTRICAL PANEL SCHEMATIC Scale: NTS PVC conduit 3 cinducic+rs tics lase in �rallel See NOTE 1 below Length of cable In feet (one-way distance) Calculate Voltage Drop Reset Estimated voltage drop See NOTE 2 below SERVICE FEEDER VOLTAGE DROP Scale: NTS Avallable Fault Current Calculation Gy:. Jeb.n Sokolik `tier, 6.6 Utility Symmetrical Fault Current amperes kVA = 150 ,m .1 torn st.net E = 208 = kVA x 1ti130 = trains. FLA trans. FLA = 416 E x 1.732 Isca = trans. FLA x 100 x PF PF = 100% transformer Z Z 2.00°l lsca = ampere short-circuit current RMS symmetrical, I sca 20,819 amperes Point to Point Method ° Three Phase 208/120... � Length (distance) FEET ', L - 410 Aluminum in Nonmetallic Racewayh 1.732 x L I (ASC) : ,Ism 20,819 N, x C x E L-N # conductors per phase N _ Phase conductor constant C 21,3 1 Phase Conductor 500 cmel ., ... _ :. Volt Line to Line E L - L 203, Volt f 1,108 Neutral conductor constant C - 21,391 Neutral Conductor 5no Emil Multiplier Volt Line to Neutral E L- N = 120 Volt f = 1.920 1 »_ 1 +f Line to Line M 0.474 Fault Current from Line to Neutral: M � 0.342 Transformers to Fault Current at Service Equipment Main Disconnect Switch Isca... fault current at terminals of main disconnect L- -L _ - - 8 amperes Isca ... fault current at terminals of main disconnect L- N = 7,130 amperes Fault Current from are Metal Raceway � -_ Length (distance) L Three Phase " = a _.. _ Three Phase Feeder 1.732 x L x I (AC) Isea = 9,878 Phase 7,130 Neutral N x C x' E L-N # conductors per phase N 2 Phase conductor constant C - 12,844 Phase Conductor 3/0 Volt Luse to Lute E L - L _ 208 Volt f 0:016 Neutral conductor constant C = 12, 41 Neutral Conductor 3/0 Volt Lime to Neutral E L -'N = 120 Volt Multiplier f = 0.020 M = 1 Line to Line M = 0.984 Fault Current 'C Line to Neutral M= 0.9 0 Panel 'A' Ica x M = fault current at terminal of the panel L- L = 9,722 amperes ]sea x M = fault current at terminal of the panel L- IN = 6,99Q amperes Branch Circuit Fault from», Co tin Metal Raceway Length distance Three Phase Branch L_ 0 Three Phase .732 x L x I (ASC) [sea = 9,722 phase 6,990 Neutral' N X C X E L-N # conductors per phase N 1 Phase conductor constant C = 12,844 Phase Conductor 31/0 Volt Line to Line E L - L = 208 Volt f = 0,032 Neutral conductor constant C = =844 Neutral Conductor 3/0 Volt Line to Neutral E L - N = 120 Volt Multiplier f - 0,039 M = 1 Line to Line 1 + f Line to Neutral M M - 0,9 = 0 962 Fault Current at 'B' Panel Inca x M - fault current at terminal of the panel L- L - 9,425 amperes Isca x M _ fault current at terminal of the panel L- N = 6,726 amperes MAIN BONDING JUMPER BARE COPPER CONDUCTION MINIMUM OF 20'-0" OF 1/2" REBAR IN BUILDING WALL FOOTING, (NEC 250-50C) - CADWELD OPTIONAL FOR EXISTING SLAB LIFER. 3/4" X 10' GROUND ROD (NEC 250-52) COLD WATER SERVICE ENTRANCE (PROVIDE SIMILAR CONNECTION TO FIRE PROTECTION WATER SERVICE ENTRANCE), (NEC 250-50A) G FAULT CURRENT CALCULATION Scale: NTS NEUTRAL BUS GROUND BUS (1)#6 TO PHONE BOARD PER NEC 800-40(D) BARE COPPER GROUNDING ELECTRODE CONDUCTOR (NEC 250-66) \-CADWELD BONDING JUMPER TO PANELBOARD ENCLOSURE SIZE PER NEC 250-122 VALVE, METER `o SUPPLY OR SIDE BUILDING STRUCTURAL UNION STEEL (NEC 250-52(A)(2) --(�-.1 PIPE CLAMP (TYP.) CADWELD JUMPER NOTE: ALI GROUNDING SHALL BE INSTALLED IN ACCORDANCE WITH ARTICLE 250 OF THE NATIONAL ELECTRICAL CODE. Scale NTS CONSULTANT: SEAL: SEAN PATRICK PIC-KELL, PE 83946 No. 83946 s TAT50F THIS DRAWING SHALL NOT BE USED FOR CONSTRUCTION PURPOSES UNTIL THE SEAL AND SIGNATURE OF THE RESPONSIBLE REGISTRANT APPEARS ON THE DRAWING, AND PROPER PERMIT FORMS AND RELATED FEES ARE TRANSMITTED BY THE OWNER, OWNER'S AGENT OR CONTRACTOR TO THE AUTHORITY HAVING JURISDICTION,. DATE ISSUED FOR REV 09/27/201 8 PEMB COORDINATION 11/27/2018 OWNER REVIEW 12/18/2018 PERMIT SUBMITTAL Project Manager Drawn L. LONG G. COLLINS Project Leader Checked L, LONG M. GOOD Date Dept Mgr Approval 08/07/201 8 M. GOOD Client PALMETTO ZEPHYRHILLS-20th St, LLC P.O. BOX 1615 THOMASVILLE, GA 31 792 Office: (229) 226-0682 Contact: John Tate Project DOLLAR GENERAL 38965 CR 54 Zephyrhills, FL 33542 (City of Zephyrhills) Store #: 20360 Drawing Title THREE PHASE ELECTRICAL PANELS DO NOT SCALE DRAWING Project No. Drawing No. JCDT.18.0233 E5 Q DEVICE SCHEDULE SYMBOL DESCRIPTION CABLE TYPE SUPPLIED INSTALLED NOTES BY: BY: AT AHU TERMINAL STRIP 8C T-STAY CABLE EMS GENERAL ONE (1) PER HVAC UNIT. SUPPLIER CONTRACTOR OUTDOOR AIR TEMP BELDEN $761 OR EQUIVALENT EMS GENERAL ONE (1) PER RECEIVING ENTRY. OT MTD. @ 8'-0" A.F.F. (22AWG, 2C, STRANDED, SHIELDED) SUPPLIER CONTRACTOR ST TS Q PHONE COMBO. (CAT 5) DATA CABLE. CONTRACTOR CONTRACTOR MOTION SENSOR SWITCH. LEVITON EZ-FIND ODS-10-1DW GENERAL GENERAL ONE (1) PER RESTROQM. m CONTRACTOR CONTRACTOR SUPPLY TEMP (501-1121) BELDEN 8761 OR EQUIVALENT EMS GENERAL ONE (1) PER HVAC UNIT. MTD. IN SUPPLY DUCT (22AWG, 2C, STRANDED, SHIELDED) SUPPLIER CONTRACTOR TEMPERATURE SPACE SENSOR BELDEN 8761 OR EQUIVALENT EMS GENERAL ONE (1) PER HVAC UNIT ZONE. (809-6590) MTD. @ 8'-0" A.F.F. (22AWG, 2C, STRANDED, SHIELDED) SUPPLIER CONTRACTOR RJ-11/RJ-45 DATA JACK, 24 GA., 4 TWISTED -PAIR, CATEGORY -FIVE GENERAL GENERAL ONE (1) AT OFFICE COMPUTER CART. SENSOR PLAN KEYED NOTES SENSOR PLAN KEYED NOTES ALWAYS INSTALL THESE SENSORS AT 8'-0" A.F.F. THE EXACT MOUNTING LOCATION OF THE HVAC SENSORS "TS" MAY VARY DEPENDING ON THE STORE LAYOUT &DUCT CONFIGURATION. REFER TO SITE SPECIFIC MECHANICAL DRAWINGS FOR HVAC ZONED SENSOR MOUNTING LOCATIONS. IF SENSORS ARE MOUNTED ON EXTERIOR WALLS DUE TO DUCT CONFIGURATION, THEY ARE THEN TO BE INSULATED TO PREVENT AIR INFILTRATION. 6 5 4 3 2 1 @ 8'-0" A.F.F. �, OT ma�... fj GENDER NEUTRAL (' ELECTRICAL PANELS SS.. \\ L........._.._� EMERSON PRE-PROGRAMMED E2 CZ-100 CONTROLLER \ "EMS PANEL", MTD. NEXT TO \ \ TO RTU-1 ELECTRICAL PANELS, AS CLOSE F \ TO RTU-2 (` k AS POSSIBLE. \ \ 1 m \ \ GENDER NEUTRAL E \� \ 105 I a \\ \\ S S \� , -- ----- ----- ---- ---- ---- ----- ---- ---- ---- ---- ---- ---- --- ---- ---- ---- ---- _...._..... I �- --- - ---- --------------- \ �kBREAKROOMI E I \ \ \ \ _ SALES AREA xs x \ 102 \ k_ ST AT ST PROVIDE AND INSTALL ti ONE (1) 24 GA., 4 TWISTED PAIR, CATEGORY -FIVE (CAT5) RECEIVING AREA RTU-1 RTU-2 103 DATA CABLE WITH MODULAR COMBO RJ-11/RJ-45 JACK AT V�) .. E OFFICE. RJ-45 CABLE TO BE I ,: ,11 RUN FROM JACK, TO I REGISTER IN CONDUIT. OFFICE i I 0 NOTE: PLAN IS DIAGRAMATIC ONLY. HOLD CONDUIT TIGHT TO EXPOSED MAIN GIRTS ° I AND RUN AS HIGH AS POSSIBLE ALONG 1� ' PERIMETER WALLS TO RECEIVING AREA. E I � _ i / �..✓ xt �` ice`"„'"`� Yf.✓' ..,,,,, ^*. 1 .,-'"` ._`r..1�\".`;:.wC?..o'"r^' :.i..rY,_.__'/" "a»`,,,,,,...,,,,`.n,_ ",V......d.;.. ..,'� E [ a i =J NORTH - - 1 EMS/LOW VOLTAGE -FLOOR PLAN CONSULTANT: SEAL: SEAN PATRICK PIC-KEEL, PE 83946 \N\�t4iiitflttl11��� .` F39'.46 THIS DRAWING SHALL NOT BE USED FOR CONSTRUCTION PURPOSES UNTIL THE SEAL AND SIGNATURE OF THE RESPONSIBLE REGISTRANT APPEARS ON THE DRAWING, AND PROPER PERMIT FORMS AND RELATED FEES ARE TRANSMITTED BY THE OWNER, OWNER'S AGENT OR CONTRACTOR TO THE AUTHORITY HAVING JURISDICTION. DATE ISSUED FOR REV 09/27/2018 PEMB COORDINATION 1 1/ 27I 20 18 OWNER REVIEW 1 2/18/2018 PERMIT SUBMITTAL Project Manager Drawn L. LONG G. COLLINS Project Leader Checked L. LONG M. GOOD Date Dept Mgr Approval 08/07/2018 M. GOOD Client _ PALMETTO ZEPHYRHILLS-20th St, LLC P.O. BOX 1615 THOMASVILLE, GA 31 792 Office: (229) 226-0682 Contact: John Tate Project DOLLAR GENERAL 38965 CR 54 Zephyrhills, FL 33542 (City of Zephyrhills) Store #: 20360 Drawlrag. Title EMS/LOW VOLTAGE PLAN DO NOT SCALE DRAWING Project No. Drawing No. JCDT.18.Q233 EMS1 ' L1V-1\-"VV,V II\/— IVI\ I ENSURE THAT THE BATTERY ENABLE IS SWITCHED TO THE "ON" POSITION Scale: NTS Pre -Programmed e2 cx-100 Controller Escalation Contact List If you need HVAC Maintenance, call 866-300-0004, option 1. If you have Temperature Set Point concerns, contact your District Load licenses if Manager. applicable If you are having problems with 528-5134 your Lights, call 866-300-0004, 528-5096 option 6. Load E2 Setpoints If you are having problems with file Load IP address your Coolers, call 866-300-0004, information option 2. If you are having problems with your Sign, call 866-300-0004, ® option 1. If your store hours change, call r�Fll rF21 FF41 Fs 866-300-0004, option 6. ® 2 3 6 4 G) I "IMIGISOLM ID 8 9 r� %30000100IS0 ! orD, (D(E� CAUTION! 0 ®®® All power must be shut to off prior wiring, ��������ED 0 ® o installation, t service. ® ®® "" "` More than one disconnect may be required to de -energize this panel. E Inside lights override Outside light override Sign light override Verifying the Time and Date From the la} Home screen. 1. The Date is in the upper left corner of the Home screen. 2. The Time is in the upper right corner of the Home screen. HVAC Control Status Press the 12 Home screen button. Select F1 AHU. * Using the arrow keys, highlight the appropriated HVAC Unit, select enter. From the screen you can view: i. Ctzl Temp (Control Temp - The sales floor temp). ii. Values in [ I represent the set point we are trying to maintain. iii. Space Temp (Temperature at problem on Sales Floor), iv. Supply Temp (Air Temp leaving AHU). v. Status of Fan/Heat/Cools * When complete, select the 0 Home button. Lighting Status * The status of Store Lights can be viewed in the bottom left corner of the 12 Home page, or by the following: * Press the 12 Home screen button. * Select F2 Lighting. Highlight the appropriate Lighting Control, then select enter. * When complete, select the ink Home button. Refrigerated Case Status * Case Temperature can be viewed from the 12 Home screen. To view a graph of the case temperature: i. Highlight the Temp value and select enter. ii. Select 1 for graph. To zoom select F5 Zoom -In. (Press F5 Zoom -In as many times as necessary, get to the desired scale/range). (Use the left and right arrow keys to move to the time/date range desired). * When complete, select the fl Home button. Alarm Status From the 12 Home screen, select Alarm button. 1. Date: The date the alarm occured. 2. Time: The time the alarm occured. 3. State: Notice, Alarm or Fail. Notices are general warnings that notify a user of minor errors.. * Alarms are warnings about important system conditions that need immediate attention. Fails are high priority conditions, warning the user of a controller or device failure. 4. Property on Board and Point: The item that has generated the alarm. 5. Message: The description of the notice, alarm or fail. a. Using the up or down arrow keys, highlight the appropriate alarm and select F4 Expd. Info. I. Expd. Info: Expanded Information will give the unit & detailed status on the alarm. ii. When finished viewing detailed status, select enter. * When complete, select the Q Home button. NOTE: EMS SYSTEM SHOULD BE TESTED FOR HVAC OPERATION, INTERIOR LIGHTING, EXTERIOR LIGHTING AND SIGN LIGHTING PRIOR TO CONTRACTOR'S ELECTRICAL POSSESSION DATE. USE OUTSIDE LIGHT AND SIGN LIGHT OVERRIDE FOR EXTERIOR TESTING. Sc,gle: NTS HVAC Control Wires To Utilize Standard 8 Conductor, 18 Ga., Color Coated. See Photo This Sheet. COM 485 OUT 16AI 1 16A1 2 0 8RO Q BBB Q SRO Q. BBB Q 12 0HVAC1 24Vac SENSOR '® I,0 CONNECTIONS a,ssa3z 0 cs 32 - - ore oHVAC1 Supply Fan 0 @ HVAC1 Heat1 ��®�®�®� o HVAC1 Heat2 DOOR SW FRONT e�' ' y AC#4 SPACE TEMP w° DOOR SW EM_/EXIT lac m��' 0 AC#4 SUPPLY TEMP 0 g®gg®@®�,1, 0 HVAC1 Coo12 p�wgW��° DOOR SW RECEIVING �. rB- 0g LL Np AC#5 SPACE TEMP 0 nay N O HVAC2 24Vac ®(1���(I��.t NN (1�®®®�®$. y ICE CREAM �� ms. FREEZER TEMP B e' AC#5 SUPPLY TEMP By. Q HVAC2 Supply Fan DAIRY COOLER TEMP 0 '6'6 0 0 AC#6 SPACE TEMP B = 0 66 0 0 HVAC2 Heat1 LUNCH MEAT B 0❑ 0 B OS 0 COOLER TEMP B AC#6 SUPPLY TEMP 0 V HVAC2 Heat2 AC#1 SPACE TEMP 0 0 0 COOLER TEMP. B, a 0 0 e o �- 0 0 HVAC2 Cool1 OS 0 0 0 AC#1 SUPPLY TEMP 4 COOLER TEMP. s p 0 0 0 p 0^ 0 HVAC2 Cool2 0 Q 0 0 0 o e Q 0 0 ® HVAC3 24Vac 0 m'N 0 0 ; 0 FREEZER TEMP. B"� OS ; 0 0 HVAC3 Supply Fan a" 0° 0 0= 0 o HVAC3 Heat1 HVAC3 Heat2 AC#2 SPACE TEMP B, 0 0 0 FREEZER TEMP. 0 a 0 0 ti 0 AC#2 SUPPLY TEMP B 0 HVAC3 Cool1 FREEZER TEMP. - 0 0 ® AC#3 SPACE TEMP B a 0 B 0 0 O HVAC3 Coo12 AC#3 SUPPLY TEMP B_ 0❑❑ 0 _ B 0 ❑ p HVAC4 24Vac e SPARE 0 o J 0 ®® HVAC4 Supply Fan 0 0 OUTSIDE e o_ OS 0 e r_ e TEMPERATURE B 0 �. 0 ® HVAC4 Heat1 0 "_ 0 0 0 0 0 ° O OTION SENSOR raoNr B- `""` 0 V ,. 0 HVAC4 Heat2 B 0 ®® HVAC4 Cool ® HVAC4 COOL_] Q Q Q NOT USED Q Nor USEo HVAC5 24Vac 00 00 HVAC5 Supply Fan D o c o c O c o � > — HVAC5 Heat1 0 U) N N o o HVAC5 Heat2 o o HVAC5 Cool1 8RO 3 our T2 o"r3 OUTI ours ° 6 opn 0 HVAC5 Coo12 Q o ® Q° a 13 ® a a °®Q HVAC6 24Vac °Ua® HVAC6 Supply Fan ® HVAC6H' eat1 ❑❑❑❑❑❑❑❑w o o HVAC6 Heat2 0 a o o °°gip°°o oLr"`° HVAC6 Cool1 [1,N7­T eevp'F T61.Ow°HVAC6 Cool2 EaurvnLervT MODEL 810-3006 aT* ®covAc UZF MnzEnc ® p ""T OUT1 OUT2 OUT3 OUT4 OUT5 OUT6 OUT7 OUT8 0 ea@ I mem BBB ema eae mme mma mme NG1 N N" N NG3 N I NC4 N NC5 TJNG6 N NC7 —NJ NG B NO CJ � I®®®®®®®®ol Q,z3as aaseTs S2 FAILSAFE ON(UP) For N.C. Q 511NETWORK 52 FAILSAFE Outputs OFF(DOWN) For N.O. Outputs NEUTRAL O ° o 120vAC 24V CT 24V o o A -- Iwo � 10VA GROUND 24vAC Oo 80VA ° ° 240 208C 120 ° o 0 o ° 0 50VA ° O o ° PANEL/CIRCUIT o 0 0 ❑�❑ PANEUCIRCUIT B/5 0 B/7 0 N N 70% Lights ®� ° B/13 B/9 0 W 30% Lights ®u ® B/15 B/11 ®c 0 u ® ❑®❑ C3 o C1 ®" r ®� 70% Lights ° 0" ® B/27 0 w w 0 Outside Perimeter ®` ` ® ° ® B/29 Lights 0 @� C4 0 � u ® B/31 ®r c ® B/33 0@0 13/41 0 " r ® ° ®ry ® Dusk To Dawn C2 0®171 O w w ® Lights Outside Perimeter ®ry ® B/37 ®r ° Lights u u ® B/39 C5 ° ❑®� C7 ❑Q❑ B/1 ®� ®E] B/3 0 N ® Receiving O w u ® & Night lights B/23 ®� r Sign Lights ® B/25 C6 C8 TESTING NOTES TESTING OF HVAC UNITS THRU EMS PANEL IS ACCOMPLISHED BY SIMPLY WARMING UP OR COOLING DOWN A SPACE TEMPERATURE SENSOR (USING A BLOW DRYER OR ELECTRONIC EQUIPMENT DUSTER AEROSOL) AND WATCH THE FAN, HEAT AND COOL STAGES CYCLE ON AND OFF, THIS REQUIRES TWO PEOPLE AT ALL TIMES .... ONE TO WATCH THE SCREEN AND THE OTHER TO WATCH OPERATION OF THE AHU. WHEN COMPLETE, PRESS THE HOME BUTTON TO RETURN TO THE MAIN SCREEN. ENDS GENERAL NOTES 1. EMS SUPPLIER NOTE: CUSTOMIZED DOLLAR GENERAL EMS PANEL REQUIRES STORE #, CITY, STATE, ZIP CODE & QTY. OF HVAC UNITS OF THE INSTALL SITE WHEN ORDERING. EMS SYSTEMS INSTALLATION GUIDE WITH PHOTOS IS AVAILABLE ON NATIONAL ACCOUNT WEBSITE. ALL QUESTIONS PERTAINING TO THE EMS PANEL, SYSTEM INSTALLATION & SETUP SHOULD BE DIRECTED TO EMERSON'S DOLLAR GENERAL SUPPORT TEAM AT 770-425-2724- 2. ALL SIGN & LIGHTING CIRCUITS MUST BE FED THROUGH THE DESIGNATED CONTACTORS AS NOTED ON THIS PAGE. 3. ALL LOW VOLTAGE HVAC & DOOR SENSORS MUST BE CONNECTED TO THE PROPER TERMINAL. 24 GA. SHIELDED (SHIELD MUST BE GROUNDED) CABLE, BELDEN #8641, 2 CONDUCTOR WIRE OR IT'S EQUIVALENT IS REQUIRED. 4. COOLER & FREEZER HOME RUNS WILL BE TERMINATED AT ALL POINTS BY DOLLAR GENERAL REFRIGERATION DEPARTMENT. CONTROL WIRING DIAGRAM Scale: NTS CONSULTANT: SEAL: SEAN PATRICK PIC-KELL, PE 83946 ��t}ttllllll . No. 83946 1~ '• STATE Or' � y r f l p}q tr!!�lltttt� THIS DRAWING SHALL NOT BE USED FOR CONSTRUCTION PURPOSES UNTIL THE SEAL AND SIGNATURE OF THE RESPONSIBLE REGISTRANT APPEARS ON THE DRAWING, AND PROPER PERMIT FORMS AND RELATED FEES ARE TRANSMITTED BY THE OWNER, OWNER'S AGENT OR CONTRACTOR TO THE AUTHORITY HAVING JURISDICTION. DATE ISSUED FOR REV 09/27/201 8 PEMB COORDINATION 11/27/2018 OWNER REVIEW 12/1 8/201 8 PERMIT SUBMITTAL Project Manager Drawn L. LONG G. COLLINS Project Leader Checked L. LONG M. GOOD Date Dept Mgr Approval 08/07/2018 M. GOOD Client PALMETTO ZEPHYRHILLS-20th St, LLC P.O. BOX 1615 THOMASVILLE, GA 31 792 Office: (229) 226-0682 Contact: John Tate Project DOLLAR GENERAL 38965 CR 54 Zephyrhills, FL 33542 (City of Zephyrhills) Store #: 20360 Drawing Title CPU TREMINAL DIAGRAM DO NOT SCALE DRAWING Project No. Drawing No. JCDT.18.0233 EMS2 - - r - -_. - F. _ I I I I III I I I I -_U I I I I -- - - - _ _ - - — - I11 _F - - r fa r' fir! _ _.., P W - W J/ f NORTH PROPERTY LINE N89753477274.07' ...,.,,_...... �..__.. (-°W _.__ __..._.., P ice( _ ____...___.PW P w . �_ m �W PW pw COUNTY ROAD 54 E (pUB, r) SITE LIGHTING AND POWER PLAN Scale: I"=20'-0" TRANSFORMER ON EXISTING POLE' ELECTRIC FOP CONNECTION) _ EXISTING UTILITY POLE WITH NEW TRANSFORMERS. VERIFY EXACT LOCATION AND SERVICE VOLTAGE WITH UTILITY COMPANY LIGHT POLE CHAMFER EDGES ON BASE GROUND LUG W/ #4 AWG CU TO REBAR IN FOOTING BASE PLATE AND ANCHOR BOLTS (BY MANUFACTURER) BASE COVER a CI' 3-#3 TIES WITHIN 5" v • FROM TOP a ° 4 1 545 VERTICAL REBAR M 1 v T I GROUNDING CONNECTORS °: v a FINISH GRADE .a . ° G ° NOTE: LIGHT POLE, BASE PLATE AND ANCHOR BOLTS SMALL BE DESIGNED #4 COPPER AND PROVIDED BY THE LIGHT POLE GROUND WIRE MANUFACTURER. UPON REQUEST BY °. a THE LOCAL BUILDING OFFICIAL, CALCULATIONS SHALL BE SUBMITTED v 4• ° o CONDUIT & WIRING r, . BEARING THE SEAL AND SIGNATURE f 7 OF A PROFESSIONAL ENGINEER a a a LICENSED IN THE STATE WHERE THE PROJECT IS BEING CONSTRUCTED, V #3 TIES @ 12" O.C. EMPLOYED BY THE LIGHT POLE MANUFACTURER. ° T'It 4 ° 4 #15 FELT (2 LAYERS) M . 3" MINIMUM GROUND PLATE (COPPER) OR 24" DIA 10-TURNS OF #4 BARE COPPER WIRE PANCAKE (20' MINIMUM) 2 POLE FOUNDATION DETAIL Scale: NTS LIGHT FIXTURE DESCRIPTION TYPE DESCRIPTION COUNT SINGLE HEAD LED PARKING LOT FIXTURE, TECHLIGHT LIGHTING: #LSBT-1C-8-T3-F-1-BZ FULL CUTOFF, WITH TYPE 3 OPTICS, DARK BRONZE HP FINISH. MOUNT ON 25' POLE, TECHLIGHT #SSP-25-4-7-11-BZ FOR SINGLE MOUNTED 1 LUMINARIE. PROVIDE A S-0" POLE BASE DOUBLE HEAD LED PARKING LOT FIXTURE, TWIN MOUNTING, TECHLIGHT LIGHTING: TWIN #LSBT-1 C-8-T3-F-R/L-BZ, FULL CUTOFF, WITH TYPE 3 OPTICS AND DARK 1 HP2 BRONZE FINISH. MOUNT ON 25' POLE, TECHLIGHT #SSP-25-4-7-11-BZ FOR DOUBLE MOUNTED LUMINARIES. PROVIDE A 3'-0" POLE BASE .. SITE LIGHTING NOTES 1. FINAL SIGN CONNECTION AND UNDERGROUND CONDUIT IS LANDLORD RESPONSIBILITY. PROVIDE CONDUIT FROM THE ELECTRICAL PANEL TO LOCATION OF THE MONUMENT SIGN BASE. BURY CONDUIT UNDER PARKING AREA. THE CONDUIT IS TO BE 1" AND HAVE ONE SET OF 6/2 WIRE WITH GROUND AND A 20-AMP SINGLE POLE BREAKER AT THE PANEL. A TEMPORARY 3' TALL STAKE SHALL BE PROVIDED TO DESIGNATE THE MONUMENT SIGN LOCATION UNTIL THE SIGN IS PERMANENTLY INSTALLED. O REMOVE POST AFTER SIGN IS 0 _ INSTALLED. 2. SEE SHEET E2 FOR BUILDING MOUNTED LIGHTS INFORMATION. 3. COORDINATE LOCATION OF LIGHT POLE BASES WITH CIVIL FOR REQUIRED CLEARANCE FROM THE RETAINING WALL BASE. CONSULTANT: SEAL: SEAN PATRICK PIC-KELL, PE 83946 �titi�tlt�Nllitta \vNv'A1 *t%CK pt�' p STATE o F kt ON 7�lJ�tifft1i21� THIS DRAWING SHALL NOT BE USED FOR CONSTRUCTION PURPOSES UNTIL THE SEAL AND SIGNATURE OF THE RESPONSIBLE REGISTRANT APPEARS ON THE DRAWING, AND PROPER PERMIT FORMS AND RELATED FEES ARE TRANSMITTED BY THE OWNER, OWNER'S AGENT OR CONTRACTOR TO THE AUTHORITY HAVING JURISDICTION. DATE ISSUED FOR REV 09/27/201 8 PEMB COORDINATION 11/27/2018 OWNER REVIEW 12/1 8/2018 PERMIT SUBMITTAL Project Manager Drawn L. LONG G. COLLINS Project Leader Checked L. LONG M. GOOD Date Dept Mgr Approval 08/07/2018 M. GOOD Client PALMETTO ZEPHYRHILLS-20th St, LLC P,O. BOX 1615 THOMASVILLE, GA 31 792 Office: (229) 226-0682 Contact: John Tate Project DOLLAR GENERAL 38965 CR 54 Zephyrhills, FL 33542 (City of Zephyrhills) Store #: 20360 Drawing Title ELECTRICAL SITE LIGHTING AND POWER PLAN DO NOT SCALE DRAWING Project No. Drawing No. JCDT.18.0233 ES1 Luminaire Schedule Symbol Qty Label Lumens/Lamp Arrangement LLF Description 5 G N.A. SINGLE 0.900 LHSWP-1-C-M-T3-C-ONE BRICK TYPE 3 700MA LED WALL PACK - 5 HB N.A. SINGLE 0.900 LSBT-1-C-X-T3-F-ONE BRICK TYPE 3 1400MA LED WALL MNT 421N UPSWEEP ARM -� 1 HP N.A. SINGLE 0.900 LSBT-1-C-X-T3-F-ONE BRICK TYPE 3 1400MA LED ( SEE NOTES) g 1 HP2 N.A. TWIN 0.900 LSBT-1-C-X-T3-F-R/L-ONE BRICK TYPE 3 1400MA LED 2@180 ROTATE OPTIC ( SEE NOTES) Luminaire Location Summary LumNo Label Z Tilt 1 G 16.5 0 2 G 16.5 0 3 G 12 0 4 G 12 0 5 G 12 0 6 HB 18.5 0 7 HB 18.5 0 8 HB 18.5 Q 9 HB 18.5 0 10 HB 18.5 0 11 HP 24 0 12 HP2 24 0 Calculation Summary Label CaleType Units Avg Max Min Avg/Min Max/Min SITE Illuminance Fc 1.01 10.2 0.0 N.A. N.A. PARKING AND DRIVE Illuminance Fc 3.07 10.2 0.0 N.A, N.A. 24' LED LIGHT FIXTURE- 25' POLE PARKING LOT (EX: GRADE AT 0.0') RETAINING WALL -� Notes: 1. Calculation at grade. 2. Sea Luminaire Location Summary for wall luminaire mounting height. 3. Arm mnt wall fixtures estimated with 2' rise from mounting. 4. Based on 25' poles plus 3' AFG bases. 5. Pole location grade is 4' below parking. 25' poles and 3' bases should make the fixture approximately 24' above parking surface. TOP OF BASE (EX: GRADE AT -1.0' THIGH CONCRETE POLE BASE GRADE (EX: GRADE AT -4.0' SCHEMATIC SITE POLE INSTALLATION DETAIL Scale: No Scale + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + 0.0 0.0 0.0 0.0 0.0 o.o 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0,0 0.0 D.o o.o o.o o.o o.0 0.0 0.0 0.o o.o o.o o.o O.o o.o o.o o.o o.o o.o o.o o.o + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 .0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 Q.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 ; 0.0 0.0 0.0 € + + + + + + + I + +[ g+ + + + + + + + + + + + + + + + + + ++( + + 0.0 +0.0 0.0 A.0 0.0 0:0 0.0 ` 0.0l +0.) i).o .0 1 0.0 o.o o.o D.o € o.o o.o� +0. o o .o o.o o.o 0.0 0.0 0.0 £ D.o 0. .0 .o 0.0 0.0 0.0 0.0 0'.o 0.0 0.0 III P � + + + l + + + + i + + �+ + + + j + + + [ + + + I + + + ; + + + + + + + o.o o.o 09 0 0.0 ( o.o o.o E o.o o. r.o o (o.o o.o o.o o.o o.o 0.0 0. o 0�'o 0.0 0.0 0.0 0.0 o.o o.o; o. o .0 0.0 0.0 0.00o o o.o o.o J #!E6 i i I + + € i + + + + + + + + + + +�pp,er�__ +nn + + + + + + + + + + + + + + + + 0.0 0.0 0.0 # 0.0 0� Oli_ Q 0- O.tL OA- O iL_- PRQPERTY LINE OA- 0 a-- 9,- ^.' 9 �.�� 8- 9 9- 98- 8 �- 9- Q-6--0.0 ;elI '.0 0.0 0.0 E ? � 3 t jIl � j + + +.+ + + + + + + + + + + + + + + + + + ( + + + + + + + + + ( + + 0.0 0.0 0.0 OA 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0,0 0.0 0.0 0.0 0.00 0.0 0.1 0.1 0.1 p.1 0.1 0.1 ( 0.1 0.1 0.1 0,0 0.0 0.0 0.0 0.0 0.0 0,0 0.0 + + + + + + + + + + + + + + + + + + + + + + � + 10. + + + + ++ j I 0.0 0.0 0.0 I D.0 0.0 0.0 0.0 0.0 1 0 1 _ _ D_.1.._.......................0..1. ___ 01 . e 0 1_.......................,0...1...........................0 11.- _._ D.,a_....,_ (11 0.,2"""""""","".. 0.3 d. 04..:,-:-, -05- ✓ 0.5 3 08 0.1 0.0 0..(2......_ 0.0 31 1.0 .0 OA 0.0 +0.0 +0.0 0.0 0 ` J .0 +0.0 +0.0 +0.0 +0.0; 1 +0.0 +0.0 +0.0 +0.0 0.0: +0.0 D.o OD.... 0_.D.. 0 ( 0.0 3 � I + o.o --a;v"- +_o .�.. ro. +0.0 +0.0 ; 0.0 0.0 0.0 0.0 0.0 +0.0 +0.0 0.0 O.Oj +0.0 0.0 0.0 0.0 +0.0 0.0 +0.0 +0.0 +0.0 +0. +0.0 + 0.0 + 0,0 + 0.0 + 0.l4j0 + 0.0 0.0 + 0.0." + O.O.w + Q # + 0.0 I +0.0 + � + ---~O:fl------ +O.t7 + �0.1 ( .o 1 o la +0.0 +0.0 0.0 '0 +0 i 0.1 +0.0 +0.0 +0.0 4010 i +0.1 +0.0 0.0 +0.0 +0.0 +0.0 +0.0 +0.0 +0.0 0.0 +0.0 +0.0 +0.0 +0.0 +0.0 +0.0 0.0 0.0 +0.0 0.0 +0.0 +0.0 +0.1 +0.2 E 0.1 0.6 +0.1 +0.8 +0.1 +0.8 +o.0 0.0 0 +0.0 +0.0 0 +0.0 +0.0 II+0.0 0.0 0.0 + + 0.0 0.0 0.0 10.0 +0.0 +0.0 +0,0 +0.0 +0.0 + + + + + + + + + + + + + + + + + + + + + + + + + I€ + + 0.4 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.7 1.0 1.8 1.7 1.4 1.1 0.8 0.3 0.1 0.0 0.0 0.0 0.0 it i .0 11 !11 0.0 0.0 + + + + + + + + + + + + + + + + + + + + + + I £ I E+ + +Q.0 0.9 1.2 1.2 1.1 1.3 1.1 1.2 1.2 1.2 1.4 1.1 1.3 1.8 3.2 2.9 2.1 1.6 1.0 0.5 0.1 0,1 0.0 0.0 0.0; I+®.0 I tj 0.0 0.0 I � �l + + + + + + + + € + + + # + + + + + ( 2.6 1.$ 1.7 1.$ 2.6 2.5 1.7 1.$ 1.9 2.8 3.0 4.6 4.4 2.8 1,9 1.2 0.6 0.2 +Q.1 + + + 0.0 0.0 O.O I !�.0 I 0.0 0.0 +0.0 + + + + + + + + + + + + + + + + + + E �; + + + � - ;� 5.6 .3 4.0 2.2 1.5 0.7 0.2 0.1 0 0.0I io (1 10.0 0.0 0.0 1 3 5 4 (; G G G (II f O p I4 i+ 'y +0.0 0.0 0.0 I; g 4.4 +5.5 + + + + + + 4.6 2.5 1.6 0.7 0 0 1 21, _____0 0 0,9 j' ;0.0 ., Ji HE11 �. �£ HJ-.LB". �[ 4.4 4.8 4.1 2.6 1.8 0.9 14 0.2 0.2 0.1 0.1I ., 0 I(` 0.0 0.0 0.0 + 4.3 5.0 4.1 + 3,1 + 2.3 + 1.3 + 0.7 + + 0.6 0.4 + 0,1 + � 0.1 �; � + 0.1 + 0.0 + 0.0 .8 F �. 1 g 3.5 2.7 1.7 .2 1.1 1.1 0.6 0.1 0.9 0.0 I € [ SI �, `. � +3.5 +2.7 +0.7 +o. .J +0 +0.1 4' 1.9 5 1.6 1.6 3 0.1 0.1 t t + t t t t t t 6.2 6.1 5.0 *A 2.7 2.1 1.9 2.2 .1 0.8 0.1 0.41 11 0.2 0.1 0.1 i„m + + + + + + + + + + w 7 _ 6.1 4.3 3.1 2.3 2.4 2.6 .7 1.0 0. 0.6 ; ;: 0.3 + 0.2 0.1 I, + 0.4 + 0.8 + 1.6 + 3.3 +G 4.7 + + 6.0 6.9 Fi) 8.4 + 8 G 8. 8:6 +.9 HB 5 t7.9 +7.5 + 8.7 + 9.1, € + 10.0 + + 5.0 + 3-5 + 2.6 + 2.9 + 3.1 1.9 + 1.3 + 1. + ((M 0.8 11, + 0.4 + 0.2 + 0.1 F i .. �f + 0,4 + 0.7 + 1.5 + 2.9 + 4.1 +A +7.0 +8.6 + 8,4 + 8. +E 8;7 19.7 +8.7 + 8.0 + 8.4 + j 9.0 + 10:2 + 8:8 + "' 6. + 5,0 + 3.5 + 2.7 + 3.1 13.2 .1 11 + 1.4 z 3 IC 10.811 11 0:8 {� + 0.4 + 0.3 + 0.1 HPCL + 0,3 + 0.6 + 1.3 + 2.2 + 2.9 ++,. 3� 4.� + 6.0 + 6.3 + 6 5 {f. .5.2 I +�� 6.9 +7.0 +1.2 +7.7 +� 6i + 5.$ + 4.7 + 3.4 + 2.4 + 2.6 _..... + 2.8 .8 + 1.1 LU 1 0 + 0.7 + 0.4 + 0.2 + 0.1 + 0.2 + 0.5 + 1.0 + 1.6 + 2.0 +�g 2 I + 4.0 + 4.6 + 5.1 + 5.6 + 5.9 + 6.0 + 6.1 + 6.2 + 6.0 + 6.0 + 5.4 + 4.9 + 4.1 + 2.9 + 2.0 + 2.0 + 2.4 .4 + 0.9 + 0�6 + D + 0.2 + 0.2 0.1 I II + 0.1 + 0.2 + 0.5 + 0.9 + 1.1 + + 1.4 1.8 + 2.4 + 3.2 + 3.9 + 4.5 + 5.1 + 5.7 + 6.5 + 6.8 + 6.0 + 4.9 + 4.2 + 3.7 + 3.1 + 2.2 + 1.7 6 + 1.8 + 1.7 + 0.8 + 4 +f 0.3 + 0.2 + 0.1 + 0.1 0.1 0.1 + 0.2 + 0.3 + 0.4 + 0.5 � + 1.0 + 1.9 + 2 + 3 + 4.4 5,7 +7.0 + A + 6.1 + 4.8 + 3.7 + 3.1 + 2.4 + 1.6 + 1.2 + 1.2 , + 1.3 + 1.2 + 0.7 + .3 + 0 '� 10.1 + + 0.1 + 0.1 £ + + + + =� + + 12. + + + + + + 1 + + + + + + + + +0.5 2 + + + 0.0 0.1 0.1 0.1 0.1 0.2 t 0.2 0.5 1.3 2. 3 4.4 5.3 6.0 6.3 5.5 4.8 i 3.8 ? 2. 2.0 1.2 0.9 0.9 0.8 0.8 0 I 0.1 0.1 0.0 + + + + + + + + + + + + + + + + + + + + + + + +1t + 0,0 0,0 0.0 0 0 0.1 0.1 0.1 0.3 1.0 1,9 2.6 3.2 4.0 4.4 1�4.5 4.2 3.5 2.9 2.3 1.6 0.8 0.4 0.4 0.3 0.3 0.2 1 Ti 0.0 0.0 0.0 E HP2 + + + + + + 10. + + + 10. + + + + + 11. + + + + + + + + + + + (; + + + 0.0 O.p 0.0 0.0 0.0 0.1 0. 1 0.2 0.5 0.8 9 1.0 1.6 2.9 3.2 2.0 1 1.1 0.9 0.7 0.4 0.2 0.1 0.1 0.1 c 0.1)�O. .0 0 0 11 0.0 0,0 0.0 I 1 + + + + + + + + + 10. + + + + + +0.0+EIS + + + 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.2 0.4 0.6 1.1 1.5 2.1 2.1 1.7 1.2 0.8 0.4 3 0.2 0.1 0.1 0.1 0.1 0 0 O,i 0.0 0.0 0.0 +0.0 II + + + + + + + + + + + + + + + + + + + 10. + li + + + 0.0 0.0 0.0 �0.0 `�, 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 D.1 0.2 0.4 0.6 0.9 L1 + + + 1.1 1.0 0.7 0.5 0.3 2 0.1 +0.1 + + + + 0.1 0.1 0.� 0,0`�1 � 'd.0°1 0.0 0.0 0.0 E " PROP 11 LINE 3® ® w - + + + + + + + + + + + + + + + + + + + I' € + - + + + + + 0.0 0.0 OA Q.0 ---6 a -0 6 -6-e -e a -e a --e-e -e-t -e r -0-1 -� z - 2 �- .3 - s....-,.....-, $ - „ ......._ - .... _ T2... .., r ._ 1.._ T I -t0-9 0.0 0.0 0.0 t o, 0.0 0,0 0.0 + + + + + + + + + + + + + + + + + + + + + + + + + + + + + �+ + + + + 0.0 0.D 0.0 0.0 0.0 0.0 0.0 0.0 0.0 O.D 0:0 O.D 0.1 Q.1 0.1 0.2 0.2 0.3 0.4 0.4 0.4 0.3 0.2 0.1 0.1 0.1 0.1 0.0 O.Q QQ. !a D 0.0 0,0 0.0 0.0 + + + + + + + + + + + + + + + + + + -,+ - - + + + + + + + + 0.0 Q.0 0.0 0 0.0 0.0 0.0 0,0 0,0 0.0 0.0 0.0 O,Q 0.9 0.1 0.1 0,2 0,2 0.2 0.2 0.2 0.2 0.1 0.1 0 1" O:D ~ 0.0 0.0 0.0 0.0 +0.0 0,0 Q.0 0.0 0.0 0.0 0.0 `"` 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0., 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 O.D 0.0 0.0 0.0 0.0 0.0 0,0 + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + +0.0 + 0.0 0.0 o.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.0 O.D 0.0 0.0 0.0 0.0 0,0 p.0 0.0 0.0 0.0 NORTH SITE LIGHTING PHOTOMETRIC PLAN Scale: 1/20" = V-01' CONSULTANT: SEAL: SEAN PATRICK PIC-KELL, PE 83946 � 1�tttii1111tt sy„ j 'E No. 8,3,946 ' STAT E 0 THIS DRAWING SHALL NOT BE USED FOR CONSTRUCTION PURPOSES UNTIL THE SEAL AND SIGNATURE OF THE RESPONSIBLE REGISTRANT APPEARS ON THE DRAWING, AND PROPER PERMIT FORMS AND RELATED FEES ARE TRANSMITTED BY THE OWNER, OWNER'S AGENT OR CONTRACTOR TO THE AUTHORITY HAVING JURISDICTION. DATE ISSUED FOR REV 09/27/201 8 PEMB COORDINATION 11/27/2018 OWNER REVIEW 12 1 2 18 PERMIT SUBMITTAL Project Manager Drawn L. LONG G. COLLINS Project Leader Checked L. LONG M. GOOD Date Dept Mgr Approval 08/07/2018 M. GOOD Client PALMETTO ZEPHYRHILLS-20th St, LLC P.O. BOX 1 61 5 THOMASVILLE, GA 31 792 Office: (229) 226-0682 Contact: John Tate Project DOLLAR GENERAL 38965 CR 54 Zephyrhills, FL 33542 (City of Zephyrhills) Store #: 20360 Drawing Title SITE LIGHTING PHOTOMETRICS PLAN DO NOT SCALE DRAWING Project No. Drawing No. JCDT..18.0233 ES2 It .� Catalog PJo€nber TYPE ' H P' A N D Project ' H P2' POLE Tyr7e TC�I<»,:IMT FEATURES SPECIFICATIONS 25°Steel " Square 7 Gauge POLE --- The pole shaft is fabricated from hot rolled carbon steel having a High EPA Reinforced Pole minimum yield of 55,000 PSI and conforms to ASTM A500 grade C require- ments. The shaft construction is a single piece of formed steel welded longi- tudinally, The hand hole is located 1' 6" above the pole base. Aground lug is Sh provided standard. High EPA reinforced poles feature a T tall reinforcement shaft welded into the standard pole shaft for maximum wind load tolerances. ANCHOR, BASE - The anchor base is fabricated from a structural quality hot rolled carbon steel plate that has a minimum yield strength of 36,000 PSI;, MountingOptions The anchor base telescopes the pole shaft and has a circumferential weld on the top and bottom. BASE COVER -A full base cover is provided which encapsulates the base plate and anchor bolts to provide a clean transition from pier to pole. DM1 DM290 DM2180 FINISH - A Super Durable Polyester powder coat finish is electrostatically applied in our state of the art paint facility. Standard colors available: Black, [ l ' ___, Bronze, US Green, White. Custom colors available upon request. Galvaniz- 3 �� �l �� �.:., i it I.....I T312 Ing and T-Guard treatments available upon request. Additional warranty ex- DM390 � T238 tensions available with these, treatments. DM490 T278 Technical Data w , Bolt Circle Nominal Pole Height 25'-0" (Always measured on thediagonal) , , 0810, Side C Shaft Dimensions 2ra' x 4" ' Wall Gauge 7 Gauge Reinforcment ShaftGauge 11 Gauge side B Side �? a Bolt � rule & 0° „ I Bolt Size 314 x30'x3° 3 ✓, i_ Sidt'A E Base Plate Dimensions 8,W sq. x .75' thk, e `z 8,01 r drilling Locations Est., Shipping Weight 2831bs _.._......_... _. Sides A B C D Max EPA (1.3 Oust) Hasid Hole E Location Nand Hole X 94 mph 12.4 —1 DMt X I 100 ph DM290 X X 110 mph 6.7 - DM2180 X x 120 mph 4,7 tiM39D _.. _ � d,_ __ -._ � _._ 130mph 34 _ DM490 X X X X 140 Mph 2.2 gg ! ORDERING INFORMATION Example: 25 4 7 11 T238 Choose the held face options for the approlm r e pole co'irnguration for your applieallon and enter on the line above 4 0 each pole aktnbute. Mcessorine may be factory installed, depending on the particular accessory chosen, but must still be ordered as a separate line item. S$p i Serlea Rafe 11eEs911 Pole Sane � l Pole Grange ltElFd� 6att0e l Color 1 —� Mounting Drill pattern ®- _ — SSP 25 25' Nominal 4 Square T 7 Gauge I 11 Gauge Bit Black Drlfl�l Drill One Side Blank None=for Tenon 2 aronze DM290 Drill 2 Sides at ` Mounting WH White DM2180 Drill i 1 , h 0 1 Sides at 84 3 SS DnBI Mount A N T : ANCHOR. BOLT KITS MUST BE ORDERED OR US Green DM390 Drill 3 Sides at90` Pattern A A SEPARATE LINE ITEM, EACH KIT IS GLV Galvanized OM490 Drill 4 Sides at 90' V VSA Drill Mount PROVIDED WITH A RIGID TEMPLATE FOR LV 1 Galvanized and Feinted T238 2-318" OD Tenon (Standard) Pattem INSTALLATION, SEE ACCESSORIES FOR KIT TO' T-Guard Internal Coaling T278 2-7I8' OD Tenon PART NUMBERS. PLEASE NOTE ON PURCHASE SP Special T312 OD Tenon ORDER IF ANCHOR BOLTS AND TEMPLATES ND No Drilling ARE TO BE PRE -SHIPPED. Accessories (Order as separate line items) NOTES 9 Mast speeifypaint color In addition to these wailing options (Example: GLVPBT, KAR34300OR AB Kit 0) 3f4' x 30` t3olts and Rigid'emplat3 TLGFIA Ground Fault Rere tacie TGBZ' GLi1PTGRZ p } KAB3430GOOR AS Kit (4) 3J4" x30°Galvani2pd Bons and Rigid Pifhla Additional }Eared Hole 2 Please note tocalion for, additional hand note when ordering, See Drilling Locations Template` diagram for location dasignationa. Techlight www.teonit htusa.com 2707.Satsuma Drive, Dallas, TX-75229 -g Pli:214.35Q.0591 Fx7214.350;9137 catalog Number TYPE ' G' Project Type TECHLIGHT FEATURES & SPECIFICATIONS Small Heat Sink LED Wall Pack APPLICATION - The high performance luminaire is designed for cutoff ap- plications where long life, low maintenance, and consistent color rendering o usLHSWP SERIES are required- Areas with limited accessibility due to fixture location or where heavy pedestrian traffic makes maintenance difficult are ideal applications such as building facade lighting or wail mounted security lighting. The tradi- tional design style of the luminaire allows it to be seamlessly integrated into existing systems when necessary. CONSTRUCTION - The heavy duty housing is constructed of die cast alu- minum. The optical assemblies are sealed in place using a silicone gasket for weather tight protection. ETL listed for wet locations (IP64). Additional IP66 rating available upon request. FINISH - A Super Durable Polyester powder coat finish is electrostatically applied in our state of the art paint facility. Standard colors available: Black, Bronze, US Green, White. Custom colors available upon request. OPTICAL SYSTEM - Made with a state of the art UV stabilized acrylic high performance refractive optical assemblies that use high transmicity materi- als to achieve precise photometric distributions. Available in a Type III beam configuration. ELECTRICAL SYSTEM - Available in a high output 2 or 4 LED system in 5000K Cool White (+/- 500K) or 4100K Neutral White color temperatures propagated with Philips Lumileds LUXEON° M LED's. Available with 90- 300V 50/60 Hz Driver. LED's rated for over 50,000 hours at 25'C ambient temperature. 0-10V dimming standard. Built-in surge protection up to 10 kV. Built-in Active PFC Function >95%/Full load. LED Power Supply conforms to UL1310 and UL8750 standards and is IP67 rated for wet locations. MOUNTING - Quick sheet metal mounting bracket connects to a standard J-Box. The bracket has a unique hanging feature to allow easy wire connec- tions, After connections are made, the fixture swings up and is secured with with two retaining screws at the top of the fixture. An additional back box is p1 available for applications requiring conduit entry (See Accessories).r4lf - - LISTINGS - LED Driver listed for wet locations (IP67). LED bricks ETL listed for wet locations (IP64). Meets US and Canadian safety standards. -40'C to 50'C ambient operation, _ . _ -._. DesignL'€ghts Consortium" Qualified. Please go to AAKV.des gniiohts.oro for the current Qualified Products List. Further details about qualified models may be found under Family Models. Serifs Housing Height Length & Wrath TYPE'Al'_ L-Bar bull"I'%linaire HIGH -OUTPUT, LIGHT -WEIGHT, ENERGY EFFICIENT LED LIGHTING SOLUTION E AWARDS2017 NOMINEE Powerful, light -weight and energy efficient, the new L-Bar is Ideal for a Lightweight Design: Low -profile, ORDERING INFORMATION Example: LHSW 1C4T3 1=Z variety of commercial applications. With an output of up to 4500 lumens, robust, polymer construction provides Choose the bold faced tans forthea propdateluminairecvnfi urat'anfor your Frt R 9 Y application and enter quick and easy installation of this orithe line above each fixture, attribute.Accessories may be actoryinstaled,depending onthe parftwlar the L-Bar IS so powerful that one linear luminaire Can replace a standard high -output light source. acc�oychoossen, but still be ordered as a separate line:ter 2'x4' commercial troffer. Weighing in at only 19 ounces, the L-Bar is so Coast Effective. Costs up to 75 percent less than a standard 2 ft x 4 fi cornmercial troffer. lightweight that it can be mounted directly to the ceiling. Wet -rated and . Energy -Efficient: Provides up to 150 lumens Series # o€ Bricks Color Temp # LED's per Brick i Optics Drive Current voltage Finish avallabie In tW0 and four f00t lengths, file L-Bar IS the Ideal GilolCe for both per watt. LHSWP 1 1 Brick C Cool white (5000K) 2 2 LEI? T3 Type III F 1400mA Driver 1 Multi -volt' BK Black indoor and outdoor environments —including offices, retail, parking garages, Mountable: Ships with flush mount N Neutral White (4100K) 4 4LED H 2100rnADriver BZ Bronze hardware Clips for fast and clears surface GR US Green stairwells, schools, hospitals —virtually anywhere you are currently using a mounting. Optional suspension mount WH White standard commercial troffer. aircraft cabling available, SP Special2 NOTES I so Z Accessories (Order as separate lisle items) t Multl, volt is an auto ranging g g power supply from 90V iq 300V input. RoHS �. caarnusrr WET PSHSENCA Back Box Enclosure with Conduit Entries 2 Custom RAL color matching is available. Contact your Techlight sale representative for additional information. LHSWPBBU 2000 Luman;90 Minute Battery Back -Up with Fixture Back Box 3 P1 000PC operates at 120V only. For photocells to operate at additional voltages, P900dPC' Button Type Photocell (requires PSHSENCR Back - please consult your local Techlight representative. Back Box Enclosure required For Button Photocell mounting. - Box} I P66° Additional IP66 Fixture Rating 4 Additional IP66 rating may not be changed once production has begun on the fixtures. 1350 DIVISION ROAD, SUITE 204, WEST WARWICK, RI 02893 1 LS G.COM I 1-877-999-5742 i 801 N ATLANTIC AVENUE, COCOA BEACH, FL 32931 www.tech lightusa,com °+Ali dim mans and specifications are subject to clang enthoncnotim'° REV 20161024-09 DesignLights Consortium' Qualified. Please go to Aww, nil h ,, r g for the current Qualified Products List. Further details about qualified models may be found under Family Models. TECHLIC T Catalog Number TYPE ' H U H P' ,' , Project & ' H P 2' Type FEATURES &SPECIFICATIONS 0 Tapered Back APPLICATION - The high performance luminaire is desi n for area light- pdesigned e g� y- Saber LED Area Light us Ing applications where long life, low maintenance, and consistent color ren- dering is required. Areas with limited accessibility due to fixture location or where heavy pedestrian or vehicle traffic makes maintenance difficult are ideal applications such as parking lots or walkways. It is also compact and versatile enough for general purpose security lighting. CONSTRUCTION - The heavy duty housing is constructed of extruded alu- minum. The optical assemblies are sealed in place using a silicone gasket for weather tight protection. Modular LED bricks wired in parallel for ease of maintenance. ETL listed for wet locations (IP64). Additional IP66 rating avail- able upon request. FINISH - A Super Durable Polyester powder coat finish is electrostatically applied in our state of the art paint facility- Standard colors -available: Black, Bronze, US Green, White. Custom colors available upon request. OPTICAL SYSTEM - Made with a state of the art UV stabilized acrylic high ' performance refractive optical assemblies that use high transmicity materials to achieve precise photometric distributions. Available in Type 11, III, IV, IV Automotive, V Medium and V Wide beam configurations. Star Light Friendly (meets or exceeds Dark Sky requirements) in the horizontal position. ELECTRICAL SYSTEM -Available in up to a 6 brick LED system in 5000K Cool White (+/- 500K) or 4100K Neutral White color temperatures (70 CRi Shown with optional Quick Mount Bracket OMB min.) propagated with Philips Lumileds LUXEONO T LED's or Usram equiva- lent, Available with 90-300V 50/60 Hz Class II power supply. LED's rated over 355,000 hours (TM21 Calculated L70) at 25'C ambient temperature with se- lectable 700mA, 1050mA and 1400mA operation. Lumen Maintenance >97% at 50K hrs. 347V and 480V input options available. Standard 0-10V dim- --20,62`°- I ming. Fixture provided with integral 10kV surge protection that meets IEEE C62.42.2-2002. Built-in Active PFC Function. LED Power Supply conforms to �It T UL1310 Class 2 and UL8750 standards and is IP67 rated for wet locations. MOUNTING -- The fixture is designed to mount directly to a square pole. An _ adaptor is available for direct mount to round poles. Techli hfs Quick Mount P P g ` 'li~ - 36.00 Bracket for flush mount or the Quick Mount Bracket with various arm lengths also available. All mounting options allow the Tapered Back Saber to mount e Dimensions shown orator 5 & 5 Brick at 90 degree intervals. Unit Only. Mounting options must be LISTINGS - LED Power Supply listed for wet locations (IP67). LED bricks ordered separately. ETL listed forwet locations (IP64), Meets US and Canadian safety standards. -40'C to 50'C ambient operation. RoHS Compliant. WARRANTY - The complete luminaire is covered by a 5-year limited warranty. ORDERING_ INFORMATION Example: LSBT6C8T5WD1-BZ Choose the bold face options for the appropriate luminaire configuration for your application and enter am s on the line above each fixture attribute. Accessories may be factory installed, depending on the particular accessory chosen, but still be ordered as a separate lima item, teREo DME rviasStBe Ordered SePa[att l} LSBT -l( 9 Series # of Bri ks Co �T,-.p LED'�p.,IckL E i s r rrzpv�--i # Br O t c D Ave Cu entVolta aFinishIs — LSBT 1 1 Brick C Cool White (5000K) 8 18 LED T2 Type Il C 700mA Driver 1 Multi -Volt' L Left Rotated SK Black 2 2 Brick Neutral White 4100K T Type lit a ( ) 3 yP D 1050mA Driver 2 4 4 Optics Z Bronze 8 V p s o ze 3 3 Brick T4 Type IV F 1400mA Driver 3 347V K Richt Rotated OR U5 Greets 4 4 Brick T4A Type IV Optic;, WH White 5 5 Brick Automotive {Leave Bank far SP Special' " 6 6 Brick T5M Type V Medium YF anra.rd nn+,�ei ENS A' J�lr ... Fir Series Housing Height Length & Width EPA (ft?) `sBT 5.63" - 36.00° X �a.62° .s Accessories (Order as separate line items) Accessories (Order as separate line items) LEDESI S-325 20W LureQnA90 Minute eatiery Back -Up (L>_nses G,dered Sepa alely) QMB Quick Nbmn leracke'-Rush, No Arm TLW3FSIR-10c Remote Handheld Sense con%Mollen Tool QMSSA-S Qzk Mount Bracket vrith 2" Sk-aightArm TLWSFSP-L2 36T leans, rox,mum coverage 48' diameter from a' haight NOTES QMSSA-M Quick Mount Bracket trim a` Straight Alm TLWSFSP.L3 3360' labs, Maximum coverage 40' diameter from kb' Height QMSSA Quick Mcmrd Bracket with 1Q75' Sfr2igntkM TLWSFSP-L4 36W lams, maYmum coverage W diameter from 40: height I Multi -Volt is an auto ranging power supply from 90V to 300V input RPASSA Round PMeMount Adatorfor Direct Mountin- 4 TLWSF3P.L7 3Bi7'let)smaximualEaveraeIWdiametorfrom 40't:. t 2 Custom RAL color matching is available.Conta ourTchli htsale � & 9 y g IP66- Add::Wnal IP66 Fixture RatltQ PPCPJ" 7-Pin Tvis'Lock. Rotocali Ra,;epiad!a ANSIG':36.41 representative for additional information. LEDOPTIC-w spill tight ErminaWn PTLJP•275 7-Pin Receptacle Strnrsng Cap 3 Additional iPf&rating may not be changed once production has begun an the LEOOPTIC-B spill Lght Elainatio;'Black Out" PC2 480V TMs. La k Photocell fixtures, TLWSFSP-211 Fhfium Mourn Passive Infrared Motion Semscrr PQ6 Mull- ap t1.5-2MVj Twist -Lock PholaGell www. tech lightusa.corri —AN dimeixsions and specificad-1 are su6jecca> change vrrthrwt notice— REV: 20170 03-05 It V 0 .875 0 WIREWAY— I 2.00 8.00 € ITEM NO. PART NUMBER DESCRIPTION QTY. 1.Q0 1 WMUPS42ARM 2" SCH 40 X 48.8$ PIPE 1 00 2 WMUPS42PLT RM148HRB8X8SQ 1 SECTION A -A t..v,. �!,UNSI.3 .N:iPt isrt_.FE,Is.. Tc,Ler{At�CES: -T t'.... I ... _,__....,._. ._ ._... S ;i.; RM I TECH G E I �s e.0v P 9b b r r �;TiG . ,_ n .c r t s, b<,'L<rCt rA I ROPRIETAiEi`AND CONrii`b Nnt ,lr ! ��. TijRE_ rs:.s i WMUPS42 i rti r *itr��l i l iHl r_ i ;y'0 MATERIAL i AN MATERIAL � Lf k t a I A F 5 � .,,v Aa.. - t! i L7 fit% k r t �t t ..C,,, r I 1Ii1I1 �.; �r; b• i WMUPS�42 ! 7, T L 'v.t,C3hl O �' N(,,T SCALE DRAVV:Nc- ; _.. _ TYPE �' ARM & MOUNTING PLATJ CONSULTANT: SEAL: SEAM PATRICK PIC-KEEL, PE 83946 0ll111111/r No. 83946 �� r 7rIIrllrilil}lj THIS DRAWING SHALL NOT BE USED FOR CONSTRUCTION PURPOSES UNTIL THE SEAL AND SIGNATURE OF THE RESPONSIBLE REGISTRANT APPEARS ON THE DRAWING, AND PROPER PERMIT FORMS AND RELATED FEES ARE TRANSMITTED BY THE OWNER, OWNER'S AGENT OR CONTRACTOR ITO THE AUTHORITY HAVING JURISDICTION. DATE ISSUED FOR REV 09/27/2018 PEMB COORDINATION 1 1 /27/2018 OWNER REVIEW 1 2/1 &/2018 PERMIT SUBMITTAL Project Manager Drawn L. LONG G. COLLINS Project Leader Checked L. LONG M. GOOD Date Dept Mgr Approval 08/07/201 8 M. GOOD Client PALMETTO ZEPHYRHILLS-20th St, LLC P.Q. BOX 1615 THOMASVILLE, GA 31 792 Office: (229) 226-0682 Contact: John Tate Project DOLLAR GENERAL 38965 CR 54 Zephyrhills, FL 33542 (City of Zephyrhills) Store #: 20360 Drawing Title SITE LIGHTING FIXTURE CUT SHEETS DO NOT SCALE DRAWING Project No. Drawing No. .JC®T.l 8.0233 ES3