Loading...
HomeMy WebLinkAbout39450 South Ave (11)I I I. I IL 11 '_. 1 1 1 111 1 I I • iAl rs ill 1 1 _ 1'_ 1. 1."f'1" Ip'.!¢!^..,.e. I .I A.1 . I. 1..7 1..! 1 I I 12,000 GALLON UL142 DOUBLE WALL FLAMESHIELD CANOPY DESIGN AST 200GPM JET -A BULKLOADING/RELIEVING SYSTEM 12,000 GALLON UL142 DOUBLE WALL FLAM--ESHIELD CANOPY DESIGN AST 200/180/18 GPM AVGAS BULKLOADING / AIRCRAFT SELF -SERVE DISPENSING SYSTEM ZEPHYRHILLS MUNICIPAL AIRPORT, FL. ZPH y 'I 4 �� •7b -al fti C7, BID# 11-21-04 FDOT FM #435216-1-94-01 REVIEW DATE_i�y-' CITY OF ZEPNYf�HIL+. FIRE AND LIFE SkFETY EA,,MINEK WORK SHALL NF A CODES AND COMPLY WITH LIST OF DRAWINGS: STANDARDS 2105-CVR: THIS COVER PAGE 2105-10: 2105-20: 2105-30 : 2105-40: 2105-50: 2105-60 : 2105-70: 2105-80: 2105-90 : NOTES JET -A TANK AND EQUIPMENT AVGAS TANK AND EQUIPMENT JET -A TANK ELECTRICAL SCHEMATIC AVGAS TANK ELECTRICAL SCHEMATIC PNEUMERCATOR SCHEMATIC JET -A TANK SYSTEM P&ID AVGAS TANK SYSTEM P&ID SUGGESTED FUEL FARM PLAN SBA -CON AVIATION SERVICES' ABA -CON INC. P.O. BOX 308 TITUSVILLE, FL 32781 PHONE: (321) 567-4967 FAX: (321) 607 6805 WEB: www.aba-con.com PROPRIETARY AND CONFIDENTIAL The information contained in this drawing is the sole property of ABA -CON Aviation Services. Any reproducton in part or as a whole is prohibited without written permission of ABA -CON Aviation Services. PROJECT CONTRACTOR: ADAMS TANK & LIFT, INC. 4568 131STAVE NORTH CLEARWATER, FL 33762 JOB NUMBER: 2105 DRAWING NUMBER: CVR WA V Z = Cl- N -� = O n = N LL Z 0-0 wO_ N Q 1= DATE: 6/18/2021 REVISIONS DATE DESCRIPTION 7/29/2021 2105-80, 2105-90 2105-70, 7/29/2021 Z2\ 2105-30 9/15/2021 2105-20, 2105-30, 2105-90 SCALE:1:80 DRAWN BY: KM APPROVED BY. - AB CLIENT: ZEPHYRHILLS MUNICIPAL AIRPORT ZE L ILLS, F OR DESIGN TEAM TITLE: Q ADAMS TANK AND LIFT INC. 4568 131 ST AVE N CLEARWATER, FL 33762 727-540-0931 NO. I DATE REVISION DESCRIPTION This item has been digitally signed and sealed by Soumya Chakrabarti, PE, on date shown. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. ,^K 1P 7"-r l�� � * , 66380 ; ATE OF oNAL Y CHKRABARTI .. SOL4 FL. REG # 66380 TANK AN 3 PtPING PLANS & DF.TAI LS SITE DESIGNATIONS: FUEL FARM REPLACEMENT SCALE: AS NOTED JOB # 01 DATE: 09-23-2021 DESIGNED BY: DRAWN BY: SS FILE NAME: CHECKED BY: DRAWING TITLE: ZEPHYRHILLS MUNICIPAL AIRPORT ZEPHYMILLS, FLORIDA SHEET NO: TA-0 1 ' LLB' Pit1Ll 11 I I I ' l! AVIATION STORAGE TANK SYSTEMS n REGULATORY REQUIREMENTS: L J '' 1. NFPA 101 Life Safe Code `s �' r �� !� REVIEW DATE d 2. NFPA 10 Standard for Potable Fire extinguishers CITY OF ZEPHYR LLS g L ti FIRE AND LIFE SAFETY EXAMINE 3. NFPA 30 Flammable and Combustible Liquid Code 4. NFPA 70 National Electrical Code (NEC) 5. NFPA 77 Recommended Practice for Static Electricity 6. NFPA 407 Standard for Aircraft Fuel Servicing ALL WORK SHALL COMPLY WITH 7. UL 142 Standard for Safety, Steel AST's for Flammable and Combustible Liquids NFFA CODES AND STANDARDS 8. UL 842 Standard for Valves for Flammable Fluids 9. ANSI/UL 87, Power Operated Dispensing Devises for Petroleum Products 10. ANSI/UL 913, Standard for Intrinsically Safe Apparatus and Associated Apparatus for Use in Class I, II, and III Division 1 Hazardous (Classification) Locations 11. American Petroleum Institute (API) Standards. Regulations and Publications, including Appendices for design, cleaning, construction, installation of tanks, piping, and dispensing system 12. API Bulletin 1500, 15425 15 81, 2000 13 . API Bulletin 1529 Aviation Hose 14. API Bulletin 1540 Design, Construction, Operation, and Maintenance of aviation Fueling Facilities 15 . PEI Standards RP-200, RP-100-90, RP-3 00, RP-400, and RP 13 00 16.ATA-103 Standard for Jet Fuel Quality Control at Airports 17.Applicable Local, State, and Federal Codes and Regulations 18.FAA Advisory Circular 150/5230-4B Aircraft Fuel Storage, Handling, and Dispensing on Airports 19.Local and State Dept. of Environmental Management 20.Approvals by Authority Having Jurisdiction 2 LNIST Handbook 44 (latest Edition) 22.OSHA PIPING: 1. System Pipe 1.0" and Larger: 304/304L, ASTM A312, SCH10 Stainless steel, flanges 304/304L, 150#, RF, ASTM A182 Elbow 90-45, reducers 304/304L, ASTM A403 SCH10 2. System Pipe 1.0" and smaller: 304/304L, ASTM A312, SCH40, Stainless steel fittings 304/304L, ASTM Al82 3. System Instrument Tubing: ASTM A269, grade TP316 stainless .035 wall seamless 4. Compression Fittings: DK-LOK 316 stainless steel 5. Systems piping shall be cleaned internally before final assembly OPERATION MANUALS: Provide (2) copies of Operation and Maintenance manuals for all equipment including parts list, instruction sheets, and other literature that is provided with systems components SYSTEM PERFORMACE REQUIREMENTS: Minimum Working Pressure Ratings* 1. Aboveground Steel Fuel Oil Piping 150 prig 2. Vent, Gauge, and Fill Piping: 100 psig 3. Fuel Storage Tank: 5 psig 4. Fuel Storage Tank, Secondary Containment Shell Walls: 5 psig 5. Fuel Control/Operating Valves: 250psi 6. Jet Tank Fuel Unloading Rate: 200pgm 7. Avgas Tank Fuel Unloading Rate: 200gpm 8. Jet Tank Recirculation Rate: 200gpm 9. Avgas Tank Recirculation Rate: 200gpm 10. Jet Bulkloading Rate: 200gpm 11. Avgas Bulkloading Rate: 180gpm 12. Avgas Aircraft Dispensing Rate: 18gpm DELIVERY, INSTALLATION AND START-UP: 1. Contractor shall provide safe installation of tanks and equipment 2. Contractor shall provide qualified service representative to supervise installation, start-up, functional testing, acceptance inspection by Owner and Authority Having Jurisdiction 3. Complete System shall be placed into service to complete satisfaction of the owner ABA -CON - AVIATION SERVICES ABA -CON INC. P.O. BOX 308 TITUSVILLE, FL 32781 PHONE: (321) 567-4967 FAX: (321) 607 6805 WEB: www.aba-con.com PROPRIETARY AND CONFIDENTIAL The information contained in this drawing is the sole property of ABA -CON Aviation Services. Any reproducton in part or as a whole is prohibited without written permission of ABA -CON Aviation Services. PROJECT CONTRACTOR: ADAMS TANK & LIFT, INC. 4568 131 STAVE NORTH CLEARWATER, FL 33762 V ) W I— O Z W I — DATE: 6/18/2021 _ ------ -- ........ - -- REVISIONS ........... DATE 1DESCRIPTION CALE:XX:XX CLIENT: ZEPHYRHILLS MUNICIPAL AFRPORT ZEPHYIRHILLS, FLORIDA DESIGN TEAM TITLE: ADAMS TANK AND LIFT INC. 4568 131 ST AVE N CLEARWATER, FL 33762 727-540-0931 NO. DATE REVISION DESCRIPTION This item has been digitally signed and sealed by Soumya Chakrabarti, PE, on date shown. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. CHAtK,Q''' * ; No. 66380 ; F :,�0 • 4 D R P F /0 'ram S�J�ti� YA C AKRABARTI FL. REG # 66380 TANK AND P 1 P I N:G PLA14S & DETAILS SITE DESIGNATIONS: FUEL FARM REPLACEMENT SCALE: AS NOTED JOB # 01 DATE: 09-23-2021 DESIGNED BY: DRAWN BY: SS FILE NAME: CHECKED BY: DRAWING TITLE: NOTES SHEET NO: TA-1 .i nld _ ........ ....... . GENERAL NOTES /' - `\ ///�7 \ 1. CAPACITY 12,000 GALLONS NOMINAL. l 16 ( 12 ( 32 \-\ 1 8 1 S 1/ � 28-1 16 / I 2. DOUBLE WALL FLAMESHIELD PE I CONSTRUCTION,G R L- 42 \ \� \� / \ �� /�_ /1 / , /� \ / TYPE 360 DEGREE WRAP, U 1 -- \ _= \ \ / / r - SHOP TEST WITH AIR AT 3 - 5 PSI' USE DOUBLE WALL TESTING PROCEDURES u - \` � / �- � � � / / 3. ATTACH TANK LABELS AS FOLLOWS: \ \\ \\ �� / / / r /-�\ 4-7 A. "UL-142" \ \ B. THIS TANK REQUIRES EMERGENCY RELIEF VENTING CAPACITY NOT LESS f / , 3 8 r � / \\ ' THAN 392,000 CU. FT./HR. C. THIS TANK IS PROVIDED WITH AN INTEGRAL STEEL FOUNDATION AND IS � o _ . 'lo?� r �� 37 i INTENDED FOR STATIONARY INSTALLATION ONLY 'TI' (� O _ �.�1 p' I - - 4. MATERIAL: CARBON STEEL / / \ 0�.. f C, o 5. ALL NOZZLE, COUPLING, AND MANWAY BOLTS TO STRADDLE NORMAL CENTERLINES OR THEIR PARALLELS, UNLESS OTHERWISE NOTED ` i �� �� _\' J 19 6. TANK INTERIOR: BLAST TO SSPC-SP10 LINE USING INTERNATIONAL INTERLINE 850 42�_� EPDXY PHENOLIC WHITE. �` -�� _ j 0 7. TANK EXTERIOR: BLAST TO SSPC-SP-6 EPDXY PRIME USING DEVOE BAR RUST 235. FINISHED PAINT USING INTERNATIONAL DEVTHANE 379UVA ALIPHATIC URETHANE ` '—`�} - \ GLOSS ENAMAL (WHITE 379K1000) y "` " `'� j _J 8. SYSTEM TO BE INSTALLED IN ACCORDANCE WITH NFP 407,30, ATA-103 ��EC 'J� 'I �--(15 1 a,! f _ �\ \ ` ` -� 9. EMERGENCY SHUT-OFF TO BE LOCATED AT LEAST 25', BU - C-�-H°AN 100' 16 �`_, - t \ ,, — 35 FROMServices. FROM TANK (BY OTHERS) (CONNECT TO ATTENDED LOCATION) 4 �- i J \ 10. APPLICABLE EQUIPMENT SUPPLIED ON THIS TANK IS COMPLIANT WITH FDEP II I �- I APPROVED STORAGE TANK EQUIPMENT LIST (EQ LIST) r� - �r II \ �% _ p 11. OVERFILL PREVENTION: I\ 23 A. WARNING: AT 90% CAPACITY, CLOCK GAUGE (ITEM 6) PROVIDES AN �` / " I� o o J \ AUDIBLE AND VISUAL ALARM AT ANNUNCIATOR PANEL (ITEM 7). 1 1 j \\ B. SHUTOFF: AT 95% CAPACITY, FLOAT VALVE (ITEM 13) CLOSES BONNET ��_ \ �', �'� 6 VENT OF HIGH LEVEL SHUTOFF VALVE (ITEM 12) WHICH THEN CLOSES, / I �; �, - . \��r PREVENTING FURTHER FUEL INPUT 1� 26 J— j �� 12. OVERSPILL PROTECTION: TRANSPORT CONNECTION, PUMP, AND PIPING ARE ALL �- WITHIN INTEGRAL EQUIPMENT DECK. APPROXIMATE CAPACITY: 200 GAL, FITTED 9 I \ � �' 1 WITH NORMALLY CLOSED MANUALLY OPERATED DRAIN VALVE (ITEM 14) \� ' \\ `� - �,�� 13. (ITEM 8) - (ITEM 12) \ /� \\ j - Z0\ (ITEM 12)THIS VALVE AND EQUIPMENT ARE USED TO SHUT OFF FUEL FLOW AT 95% �^ 1, ,� \�� �- `\ \. �_._.__I 21 \ \\ / TANK CAPACITY. ITEM #8 IS THE ANTI -SIPHON SOLENOID VALVE THAT PREVENTS \24 f �� �\ ` ' 27 \ �\ �; ' �f FUEL FROM BEING SIPHONED FROM THE TANK SUCTION PIPING. J /�1 / I��� �,, - �� �\ 43 I ` 1�" �`-. \ THE VALVE OPERATES AS FOLLOWS. THE 1/ N/O 115VAC SOLENOID VALVE IS 4 \ I � � --�� 3 6 \ �`"" � �\.__i / � 24 � INSTALLED ABOVE LIQUID LEVEL INTO 3/4"FNPT FITTING WELDED INTO FRONT TANK -� �` / I `, �1 22) `-� HEAD OPEN TO TANK INTERIOR. THE Ni0 SOLENOID VALVE BREAKS PUMP ' 29 J-- �� \� / - ~ u ° (SUCTION) BY CREATING A VACUUM LOSS IN THE SUCTION PIPING TO THE PUMP. ` _ �. j - _ _ - i THE PUMP IS UNABLE TO PUMP ANY FUEL FROM THE TANK DUE TO LOSS OF PUMP `�'� ___ _-__� ----"— ,r- a� %` \ } 1 SUCTION OR VACUUM. IF THE FILL PIPING OR SHUT OFF VALVES WERE REMOVED EQUIPMENT PLAN 10 / OR DAMAGED THE ANTI -SIPHON SOLENOID VALVE WOULD NOT ALLOW FUEL TO "-��\ i -- EMPTY FROM THE TANK DUE TO LOSS OF VACUUM. THE SOLENOID VALVE IS SCALE: 1:32 `, ALWAYS OPEN UNTIL THE PUMP SWITCH IS ACTIVATED. �� �__= _ �_ __ ---- -- ----- 11 � 3 \ - �: o / \ o i 3 0) - \ \\ i _ -- / 34 �42 \ "'CONDUIT ---- / L.., o 3 6) �! ~" 12 �\ _ -- ��` 25� _ ` f 24" MANWAY ---- I 2 CONDUIT -- o - _ _ ..� _- - �i �\ I 27` \ \ 4 ��`� ( n \ �/ _ I \ 1\------------�-------- '------- -- ---- --- -- -------- ----- 1 /1�� �� k/ \\ f j. \\ \�� J/ \� \ ;'�� ` 1863 10 _ 1 6 ) II�3 7 6 �^ 20) 3 6 u U o _ \ - (I -- \ !I � __ _ + - '26 �' \ 1 - - �� 5 I ; QTPOD / - / MULTIDISPLAY 14 , �- \� 2 \`\� \ j ,� �� ____ " -� QTPOD M4000 BACK ELEVATION FRONT E L E VAT I O N \ \ �---- -,' SCALE: 1:60 SCALE: 1 :60 TOP VIEW _- SCALE: 1:100 r 3 - 34 O� 33� \` -\ ��� 3 -� ` ��\ \\ 25) 9 4 %/ %/�\ = / \ 42 ) /�/42 1 \� ,� 6 1 - 1 - 23\, \ / ^\� I / j 15 I ^�� i I 13 \\\ 'Z'7 25 \ �\ �_ i I I I 10 � ) I51-1� 018b3 36 N SMOKING JET -A FLAMMABLE % f 2 1 /F--____ I I I \ I I N I NO SMOKING JET -A FLAMMABLE I� ( 10 I i _ `yam / / - �- ( \I (\ 20l \ %' / } 2 C 1� \i i ITEM CITY DESCRIPTION PART NUMBER MANUFACTURER ABA -CON AVIATION SERVICES 1 1 JET -A TANK 12,000 GALLON, UL-142 DOUBLE WALL, STI-FLAMESHIELD, 120" DIA. 20'-6" LONG, 72" CANOPY EQUIPMENT DECK AREA WITH SPILL CONTAIMENT OF 150 GALLONS, SLOPED SADDLE SUPPORTS, REAR RUNG LADDER, ONE EACH 24" MANWAY, FOUR ANCHOR POINTS JET -A 12,000 GALLON UL-142 DOUBLE WALL FLAMESHIELD FLORIDA EQ 352, EQ 677 MODERN WELDING 2 1 - EARTH GROUNDING COPPER -BONDED GROUNDING LUG, 5/8" X 2-1/2" LONG (MIG-WELDED TO TANK SUPPORT). - 615800 (5/8"X2.5" LONG) - ERITECH 3 4 1 2 VENT 3" TANK VENT WITH STAINLESS STEEL RISER PIPE 1 8", 8oz/sq.in. EMERGENCY VENT -FLANGED, w/O-RING (PRIMARY & SECONDARY EVENTS) 354-0300-AV 2440E-0100-AV Morrison Morrison ABA -CON INC. P.O. BOX 308 TITUSVILLE, FL 32781 PHONE: (321) 567-4967 FAX: (321) 607 6805 WEB. WWW.aba-COn.COnl 5 1 3" CAP -IRON BODY BRASS CAP (MANUAL STICK GAUGE OPENING) 178-1200-AC Morrison 6 1 INVENTORY /90%ALARM HIGH-LEVEL /25%ALARM LOW LEVEL PROBES - _ EF6-8000-A (EQ713) Greenleaf Gauge 7 8 ( 1 1 ALARM ANNUCIATOR / DISPLAY 6 DIGIT LCD DIGITAL (90%TANK CAPACITY ALARM) VALVE,SOLENOID, 1/4", N/O 120VAC COIL, EXPLOSION PROOF, WEATHER TIGHT W/VITON SEALS (ANTI -SIPHON VALVE N/0) EFG-8000-A (EQ-713) ZC1327BV402INAT Greenleaf Gauge JEFFERSON 9 1 ADAPTER-4" ALUMINUM (TANK FILL CONNECTION) PART40A PTCOUPLING 1 DUST CAP-4" LOCKING TANK FILL CONNECTION LIQUID TIGHT CAP) ( PART 40VL PT COUPLING 10 1 HAND PUMP (TANK BOTTOM SUMP PUMP) 114000-5HP-100-NUL GPI -------.-----.---.-.---...---------------------- PROPRIETARY AND CONFIDENTIAL The information contained in this drawing is the sole property of ABA -CON Aviation Services. Any reproducton in part or as a whole is prohibited without written permission of ABA 1 1 SPR. RETURN 3/4" BALL VALVE STAINLESS (HAND PUMP ANTI -SIPHON VALVE N/C) D-RING, STAINLESS STEEL, PRE -CHECK 22-061-41 3896T3 LANCE MC MASTER — 1 — CABLE, CLEAR VINYL COVERED -- --- — GTP-1093 -- ; Gammon I 1 VALVE BALL 3/4" STAINLESS, LOCKABLE (NOT SHOWN) (MAINTENANCE VALVE) 22-061-11 LANCE CONTRACTOR. ADAM S TANK & LIFT, INC. 4568 131 STAVE NORTH C L EARWATER FL 33762 r 1 ADAPTOR-3/4" (NOTSHOWN)(SUMPDISCHARGE) PART PT COUPLING ;PROJECT 1 DUST CAP-3/4' (NOT SHOWN) (SUMP DISCHARGE LIQUID TIGHT CAP) PART 3/4' V PT COUPLING 11 1 INTERSTITIAL MONITORING SENSOR/ INSTALLATION KIT LS60OLDBN-1,SK2-RM1 PNEUMERCATOR 12 1 VALVE HIGH LEVEL SHUT-OFF ANGLE VALVE 3" (95% TANK CAPACITY CONTROL VALVE HYDRAULICALLY OPERATED, DIAPHRAGM -ACTUATED, FAIL CLOSED, N/C) 268124 OCV - 1 -- 1 VALVE POSITION IND. (NOT SHOWN) (VISUAL INDICATOR) -------------- _-- -._. —_ -------------_ -...-- INLINE STRAINER (NOT SHOWN) (PROTECTS SYSTEM FROM SOLID CONTAMINANTS) 255700 ---.._.... - - — - - -- - 660704 Ocv - --- -- OCV FTG. 3/8 X 3/8 COMP MODIFIED S/S (NOTSHOWN) (CONTROLS OPENING AND CLOSING SPEED OF CONTROL 6-6-FBZ-SS �- Parker 1 SPR. OPEN BALL VALVE 1/4" STAINLESS (SYSTEM PRE -CHECK VALVE) 76-501-OIA APOLLO 1 D-RING, STAINLESSSTEEL, PRE -CHECK 3896T3 MC MASTER JOB NUMBER: 2105 1 CABLE CLEAR VINYL COVERED GTP-1093 Gammon 13 1 ° ° 95/VALVE &FLOAT (95 TANK CAPACITY MODULATING FLOAT PILOT) 230151 OCV 14 ----- 15 16 18 1 .-- 3 4 I VALVE BALL 3/4" BRASS (EQUIPMENT DECK SPILL CONTAINMENT DRAIN VALVE) 3" WAFER CHECK VALVE, VITON SEAL VALVE BUTTERFLY 3" VITON LINE STRAINER FLANGED3" XV500P-12 CV41DSVO300 310300-1101038B 286FDI 3100-AS Parker TITAN BRAY Morrison DRAWING NUMBER: 2105-20 19 1 PUMP 03C31-B 03C31-B 5.5"IMPELLER GORMAN RUPP 1 MOTOR 230V 1-PHASE 5-HP 1800 RPM L5020 BALDOR LLI Z Z Q(' I W J I— ' 1 SHEAVE/BUSHING FOR MOTOR AK71H/H-1-1/8" BROWNING 1 SHEAVE / BUSHING FOR PUMP — AK39H J H-1" - BROWNING i DRIVE BELT A28 BROWNING G --- --- 1 --- - - --- ------ ------ - - --- ----- ---- COUPLING GUARD ...- -- - -- --- - - ABA -CON ---- - ABA -CON 20 1 Starter-NEMA 7-9 EXPLOSION PROOF ENCLOSURE WITH Size "1" STARTER MOTOR, KEYED PUMP ON -OFF SWITCH & (KEYED DEADMAN OVERRIDE SWITCH) 14DUE32HAA4 SEIMENS 21 1 1 FILTER VESSEL El 1581, 6TH EDTION FILTER SEPERATOR. CATEGORY-M TYPE S. HCS-333-1436 - FACET ( 3 CM SERIES COALESCER CARTRIDGES El 1581 6th EDTION CATEGORY-M CM-335B 5 FACET 1 I SM SERIES SEPARATOR CARTRIDGE El 1581 6th EDTION CATEGORY-M SM-436FB-5 FACET 1 ARMSTRONG MODEL 21AR, AIR VENT, CAST IRON, 208PSI 21AR ARMSTRONG 1 AIR ELIMINATOR CHECK VALVE 3/4" MNPT (NOT SHOWN) GTP-2916-10 Gammon 1 SPR. RETURN 3/4" BALL VALVE STAINLESS 22 061 41 LANCE ADAPTOR-3/4" (NOT SHOWN) PART3/4"A PT COUPLING DUST CAP-3/4" (NOT SHOWN) PART 3/4" V PT COUPLING 1 VALVE, PRESSURE RELIEF, STEEL 3CRVOOF 75PSI HYDROSEAL 1 1CC WATER PROBE (NOT SHOWN) GTP-9330-1 Gammon 22 1 DIFFERENTIAL PRESSURE GAUGE GTP-534-PB-30A Gammon 1 PRESSURE GAUGE 4", LM, 160PSI, L/F, 1/4NPT, SS 9699257 WIKA 2 MILLIPORE TESTING PORTIN-OUT FLOW KIT-5 Gammon on12'MIN. 23 i 30 SECOND RELAXATION CHAMBER VCR-C 100 FACET 1 VALVE BALL 1" STAINLESS, LOCKABLE 22-081-11 LANCE ADAPTOR-1" (NOT SHOWN) PART 10A PT COUPLING 1 DUST CAP-1" (NOT SHOWN) PART 10V PT COUPLING 1 ARMSTRONG MODEL 21AR, AIR VENT, CAST IRON, 208P51 21AR ARMSTRONG AIR ELIMINATOR CHECK VALVE 3/4" MNPT GTP-2916-10 Gammon 1 VALVE, PRESSURE RELIEF, STEEL 3CRVOOF 75PSI HYDROSEAL 24 1 BULK LOADING COUPLER, 100 M/SCR, 2.5" INLET 347GF CLA-VAL SWIVEL-3" NPT, ALUMINUM 3640-0301 OPW Eng 1 HOSE EI-1529, COUPLER MXM, WJCERT SIZE: 2.5" X 12' EAGLE FLIGHT 25 1 1 3" ALUMINUM FLOATING & SUCTION ASSEMBLY SWIVEL-3" ALUM FOR SUBMERGE SERVICE (DOUBLE) FLANGED ABA -CON 3640-FJO302 OPW ENG. 1 ADAPTER-2"ALUMINUM (FLOATING SUCTION TEST CABLE PORT) PART 20F PT COUPLING 1 DUST CAP-2" LOCKING (FLOATING SUCTION TEST CABLE PORT LIQUID TIGHT CAP) PART 20VL PT COUPLING 26 27 i 1 1 1 TOTAL CONTROLS (SPA). METER WITH VEEDER-ROOT MECHANICAL REGISTER, 1/1 USG 120VAC DEADMAN / RELAY WATER CONTROL SYSTEM, ICC PROBE, MINI-DEADMAN, 25' COIL CORD 70030SPA2AG GTP-1750-3-1-2-1-1-1-3-5-25 TOTAL CONTROLS Gammon 28 1 3" VALVE EXTERNAL EMERGENCY VALVE, FLANGED, 165' FUSIBLE LINK VALVE 346DI-0300-AV Morrison DATE: 6/ 18/2021 REVISIONS 29 ( 1 REEL, GROUND 25' SPR/REWIND HGR-50 17-50 Hannay 1 CABLE, CLEAR VINYL COVERED 25' GTP-1093 Gammon 1 STOP BALL GTP-1486 Gammon 1 CABLE STOP BALL CLAMP GTP-1487 Gammon 1 CLAMP HEAVY DUTY, AIR FORCE TYPE GTP-1101 Gammon DATE DESCRIPTION 30 1 RIGHT SIDE MOUNTED LADDER /DECK PLATFORM (PAINTED OSHA YELLOW) ABA-SMCW-120 ABA -CON 31 1 GAUGE STICK 12' (NOT SHOWN) (MANUAL GAUGE STICK) 12-Jan BAGBY 7/29/2021 /\ LABELED ITEM 26. CHANGED 1 \ VISUAL STYLES TO BE CONSISTANT UPDATED BOM 32 2 VALVE SWING CHECK 3/4" STAINLESS 46635K65 MCMASTER 33 1 SPARE PLUGGED FITTING 3" FNPT 9/15/2021 / g ` UPDATED BOM. UPDATED / \ PLACARDS 34 1 INVENTORY PROBE J INSTALLATION KIT B4K2/ PK4-RM1 PNEUMERCATOR 20 GALLON ALUMINUM SUMP FUEL RECOVERY UNIT 20G-AL-SR ABA -CON i 1 SPR. RETURN 1/2" BALL VALVE STAINLESS (RETURN TO STORAGE VALVE) 22 041-41 LANCE BALL VALVE 1/2"LOCKABLE STAINLESS (WASTE SUMP VALVE)22 041-11 LANCE I I I VALVE SWING CHECK 3/4" STAINLESS 46635K65 MCMASTER 36 1 ST-15 SINGLE POINT OVERFILL PREVENTION CONTROLLER, SC-6A SCULCON JUCTION BOX, PLUG & CABLE ST-15-115-ELK / 07720 SC-6A 08156 SCULLY 37 I 1 1" ELECTRICAL POWER CONDUIT STUB ---- - SCALE : VA R I E S DRAWN BY: 38 ( 42 1 1 3/4" ELECTRICAL POWER CONDUIT STUB (FUTURE REMOTE DISPENING CABINET) EXPLOSION PROOF CANOPY LIGHT FIXTURE WITH ON -OFF SWITCH EM1120X2G KILLARK 43 1 VALVE, PRESSURE RELIEF DUCTILE STEEL 10OPSI 078DI-0300 AV or i Morrison M " �� I Q 6- 4 i 15'-6" 6" 6' '"\ / I I 12" I 20'-6" 141 26'-6" LEFT ELEVATION -' RIGHT ELEVATION SCALE. 1. 80 SCALE: 1. 80 K M 44 f i PRODUCT PIPING 1.0" AND LARGER, SCH10 304/304L STAINLESS STEEL, ASTM SA312 USA - 45 -- 46 - - — - - -- -- — PRODUCT PIPING 1.0" AND SMALLER, SCH40 304/304L STAINLESS STEEL, ASTM SA312 _-_.. ---- --—_....-------- --- -- -- -- ---- - .._ FLANGES 304/304LS/S, 150q RAISED FACE S/O FLANGE, ASTM SA182. ELBOW 90-4S REDUCERS, SCH10 304/304L S/S, ASTM SA403W PW. FLANGE GASKETS-C4401 1/16" NON -ASBESTOS. BOLTS ASTM A193 GRADE 5 STAINLESS STEEL. NUTS - HEXAGON ASTM A193 GRADE 5. -- _ ...... _..._._. --- USA __........ USA APPROVED BY. ^ AB 47 INSTRUMENT TUBING; ASTM A269, A35 WALL, 304 STAINLESS, COMPRESSION FITTINGS: DK-LOK TUBE FITTINGS 316 STAINLESS STEEL, THREAD TAPE MIL-T-27730A. USA CLIENT: ZEPHYRHILLS MUNICIPAL A I RPORT ZEPMYRHILLS, FLORIDA DESIGN TEAM TITLE: WW IN* & X 4* 4* • s ADAMS TANK AND LIFT INC. 4568 131 ST AVE N CLEARWATER, FL 33762 727-540-0931 N0. DATE REVISION DESCRIPTION This item has been digitally signed and sealed by Soumya Chakrabarli, PE, on date shown. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. CHA Kq Syq * ; No. 66380 ; �• STATE OF SOUMYA CHAKRABARTI FL. REG # 66380 TANK AND PIPING PLANT & DETAILS SITE DESIGNATIONS: FUEL FARM REPLACEMENT SCALE: AS NOTED JOB # 01 DATE: 09-23-2021 DESIGNED BY: DRAWN BY: SS FILE NAME: CHECKED BY: DRAWING TITLE: JET -A TANK AND EQUIPMLENT SHEET NO: TA-2 �\ / \ '\ /^ ITEM QTY DESCRIPTION PART NUMBER MANUFACTURER GENERAL NOTES —\ / � � � r �I f 1 1 AVGAS TANK 12,000 GALLON, UL-142 DOUBLE WALL, STI-FLAMESHIELD, 120" DIA. 20'-6" LONG, 72" CANOPY UL-142AVGAS DOUBLE GALLON 1. CAPACITY 12,000 GALLONS NOMINAL. rl (/'�j� I` g ��\l�/ i \ �' '\28% / \ 45 i /— 7 UL-142 DOUBLE WALL6 1 L+ --��-� \__ f , -� EQUIPMENT DECK AREA WITH SPILL CONTAIMENT OF 150 GALLONS, SLOPED SADDLE SUPPORTS, REAR RUNG MODERN WELDING 2. DOUBLE WALL, FLAMESHIELD TYPE I CONSTRUCTION, 360 DEGREE WRAP, UL-142 \�J/ \ i / �'\ LADDER, ONE EACH 24" MANWAY, FOUR ANCHOR POINTS FL -352, E -6 FLORIDA ABA -CO SHOP TEST WITH AIR AT 3 - 5 PSI USE DOUBLE WALL TESTING PROCEDURES 32 ( / / 3 ) 3g J EQ-3sz, EQ-677 ' \ '� i �\ /�\ �/ 2 1 EARTH GROUNDING CONNECTION. COPPER BONDED GROUNDING LUG, 5/8" X 2-1/2" LONG 615800 (5/8" X 2.5" ERITECH 3. ATTACH TANK LABELS AS FOLLOWS: i /, / \ (MIG-WELDED TO TANK SUPPORT) LONG) AVIATION SERVICES A. "UL-142" \ c �� —J / �\ 37 \) 3 1 VENTTANK3"PRESSUREVACUUM80Z I748A-3400-AV Morrison ABA -CON INC. B. THIS TANK REQUIRES EMERGENCY RELIEF VENTING CAPACITY NOT LESS /� _ Q\� 1 VAPOR RECOVERY ADAPTOR 4x3 323-0100-AA Morrison THAN 392,000 CU. FT./HR. o P.O •BOX 308 , o o , 39 , C. THIS TANK IS PROVIDED WITH AN INTEGRAL STEEL FOUNDATION AND IS \ 22 i ( o C1 =' ..- i' �� 1 VAPOR RECOVERY CAP 323C-0100-AC Morrison INTENDED FOR STATIONARY INSTALLATION ONLY / 4 z , �_ 8", 8oz/sq.in. EMERGENCY VENT -FLANGED, w/O-RING (PRIMARY & SECONDARY EVENTS TIT 2440E-0100-AV Morrison USV I LLE, FL 32781 '-' � ° `�-- �n , ,;� � ��. 4. MATERIAL: CARBON STEEL o 35 S 1 3" CAP -IRON BODY BRASS CAP (MANUAL STICK GAUGE OPENING) 178-1200-AC Morrison PHONE: (321) 567-4967 5. ALL NOZZLE COUPLING AND MANWAY BOLTS TO STRADDLE NORMAL ( i o 6 1 INVENTORY /90%ALARM HIGH-LEVEL 25%ALARM LOW LEVEL PROBES EFG-8000 A (EQ-713) Greenleaf Gauge 21 — -- �o FAX: 321 607 6805 CENTERLINES OR THEIR PARALLELS, UNLESS OTHERWISE NOTED 15 7 1 ALARM ANNUCIATOR/ DISPLAY 6 DIGIT LCD DIGITAL (90%TANK CAPACITY ALARM) EFG-8000-A (EQ-713) Greenleaf Gauge ( ) 6. TANK INTERIOR: BLAST TO SSPC-SP10 LINE USING INTERNATIONAL INTERLINE 850 �� ' %� \� B 1 VALVE,SOLENOID,1/4°, N/O 120VACCOIL, EXPLOSION PROOF, WEATHER TIGHT W/VITON SEALS WEB: f ZC1327BV402INAT JEFFERSON EPDXY PHENOLIC WHITE. o / 1 (ANTI -SIPHON VALVE www.aba-con.com 7. TANK EXTERIOR: BLAST TO SSPC-SP-6 EPDXY PRIME USING DEVOE BAR RUST 235. — { 9 1 ADAPTER-3" ALUMINUM (TANK FILL CONNECTION) PART30A PT COUPLING FINISHED PAINT USING INTERNATIONAL DEVTHANE 379UVAALIPHATIC URETHANE /-� / .... .... .... - �� / 1 DUST CAP-3" LOCKING (TANK FILL CONNECTION LIQUID TIGHT CAP) PART 30VL PT COUPLING PROPRIETARY AND CONFIDENTIAL GLOSS ENAMAL (WHITE 379K1000) 42 , / The information contained in this drawing Is the sole 10 1 PUMP (TANK BOTTOM SUMP PUMP "� 19 j HAND P M (T TT M S ) 114000 SHP-10O NUL GPI property of ABA -CON Aviation Services. an re roducton 8. SYSTEM TO BE INSTALLED IN ACCORDANCE WITH NFPA 407,30, ATA-103, NEC _. \ ------ - - ----------__----_____—______-_-_-_- _ __-__ ____._____ _____ ._-_____-..__---___-.--__-___-_ __ ___.-_.-_ _ in part or as a whole is prohibited without written \--/ 1 SPR. RETURN 3/4" BALL VALVE STAINLESS (HAND PUMP ANTI SIPHON VALVE N/C) 22-061-41 LANCE permission of ABA -CON Aviation Services. 9. EMERGENCY SHUT-OFF TO BE LOCATED AT LEAST 25', BUT NO MORE THAN 100' 1 D-RING, STAINLESS STEEL, PRE -CHECK 3896T3 MC MASTER FROM TANK (BY OTHERS) (CONNECT TO ATTENDED LOCATION) — 10. APPLICABLE EQUIPMENT SUPPLIED ON THIS TANK IS COMPLIANT WITH FDEP =- n�16J 1 CABLE, CLEAR VINYL COVERED GTP-1093 Gammon PROJECT CONTRACTOR:': APPROVED STORAGE TANK EQUIPMENT LIST (EQ LIST) 1 _ ; 1 VALVE BALL 3/4" STAINLESS, LOCKABLE (MAINTENANCE VALVE) 22-061-11 LANCE 11. OVERFILL PREVENTION: \ 1 ADAPTOR-3/4" (NOT SHOWN) (SUMP DISCHARGE) PART 3/4"A PT COUPLING A. WARNING: AT 90% CAPACITY, CLOCK GAUGE (ITEM 6) PROVIDES AN \-� I 1 DUST CAP-3/4" (NOT SHOWN) (SUMP DISCHARGE LIQUID TIGHT CAP) PART3/4"V PT COUPLING ADAMS TANK &LIFT INC. AUDIBLE AND VISUAL ALARM AT ANNUNCIATOR PANEL (ITEM 7). 17� 11 1 INTERSTITIAL MONITORING SENSOR/ INSTALLATION KIT LS60OLDBN-1,SK2-RM1 PNEUMERCATOR ' B. SHUTOFF: AT 95/o CAPACITY, FLOAT VALVE (ITEM 13) CLOSES BONNET ( 12 1 VALVE HIGH LEVEL SHUT-OFF ANGLE VALVE 3"(95%TANK CAPACITY CONTROL VALVE HYDRAULICALLY 4568 131 STAVE NORTH VENT OF HIGH LEVEL SHUTOFF VALVE (ITEM 12) WHICH THEN CLOSES, i OPERATED, DIAPHRAGM -ACTUATED, FAILCLOSED, N/C) z6B1za ocv r �, CLEARWATER FL 33762 PREVENTING FURTHER FUEL INPUT 41� 1� —( 9 1 VALVE POSITION IND. (NOT SHOWN) (VISUAL INDICATOR) 255700 ocv ' 12. OVERSPILL PROTECTION: TRANSPORT CONNECTION, PUMP, AND PIPING ARE ALL �` j 1 I i _ �,�% 1 INLINE STRAINER (NOT SHOWN) (PROTECTS SYSTEM FROM SOLID CONTAMINANTS) 660704 ocv WITHIN INTEGRAL EQUIPMENT DECK. APPROXIMATE CAPACITY: 200 GAL, FITTED /'i (23�� JI i , - T = 1 FTG. 3/8 X 3/8 COMP MODIFIED S/S (NOTSHOWN) (CONTROLS OPENING AND CLOSING SPEED of CONTROL WITH NORMALLY CLOSED MANUALLY OPERATED DRAIN VALVE (ITEM 14) (� \ ( \ �. �/ �� �� 20 VALVE) (TAMPER PROOF) 6-6-FBZ-SS Parker 13. (ITEM 8) - (ITEM 12)^�\ \ ~ l( - ` 36 �� 1 SPR. OPEN BALL VALVE 1/4" STAINLESS (SYSTEM PRE -CHECK VALVE) 76-501-OIA APOLLO (ITEM 12)THIS VALVE AND EQUIPMENT ARE USED TO SHUT OFF FUEL FLOW AT 95% l 24, 1 D-RING, STAINLESS STEEL, PRE -CHECK 13896T3 MC MASTER TANK CAPACITY. (ITEM #8) IS THE ANTI -SIPHON SOLENOID VALVE THAT PREVENTS `\ ` ' - j JOB NUMBER: \��_`-"-- � 1 .CABLE, CLEAR VINYL COVERED I GTP-1093 Gammon FUEL FROM BEING SIPHONED FROM THE TANK SUCTION PIPING. 24 - - r43)­� \, j� / \ 13 1 95%VALVE & FLOAT (95%TANK CAPACITY MODULATING FLOAT PILOT) 230151 OCV205 THE VALVE OPERATES AS FOLLOWS. THE 1/4" N/O 115VAC SOLENOID VALVE IS j i \ 1 [, / 14 1 VALVE BALL 3/4" BRASS (EQUIPMENT DECK SPILL CONTAINMENT DRAIN VALVE) I XV50OP-12 Parker INSTALLED ABOVE LIQUID LEVEL INTO 3'4"FNPT FITTING WELDED INTO FRONT TANK 1 29 1—��\ ) 26 `� HEAD OPEN TO TANK INTERIOR. THE N/O SOLENOID VALVE BREAKS PUMP �40 ���-� /_�= — ----- -` 1s z 3° WAFER CHECK VALVE, VITON SEAL CV41DSV0300 TITAN DRAWING NUMBER: (SUCTION) BY CREATING A VACUUM LOSS IN THE SUCTION PIPING TO THE PUMP. `,/-------------�- 16 5 VALVE BUTTERFLY 3" VITON 310300-1101038E BRAY THE PUMP IS UNABLE TO PUMP ANY FUEL FROM THE TANK DUE TO LOSS OF PUMP 17 2 VALVE BUTTERFLY 2" VITON ( 310200-1101038E BRAY 21 05-30 SUCTION OR VACUUM, IF THE FILL PIPING OR SHUT OFF VALVES WERE REMOVED EQUIPMENT PLAN 18 1 LINE STRAINER FLANGED 3" I286FDI-3100-AS Morrison OR DAMAGED THE ANTI -SIPHON SOLENOID VALVE WOULD NOT ALLOW FUEL TO / 19 1 PUMP 03c31 B 03C31-B 5.5" IMPELLER GORMAN RUPP EMPTY FROM THE TANK DUE TO LOSS OF VACUUM. THE SOLENOID VALVE IS SCALE: 1:32 _ --; 10 - - \ 1 MOTOR 230V 1-PHASE 5-HP 1800 RPM L5020 BALDOR ALWAYS OPEN UNTIL THE PUMP SWITCH IS ACTIVATED. \30 1 2" CONDUIT f 1 SHEAVE/BUSHING FOR MOTOR AK71H/H-1-1/8" BROWNING 1 SHEAVE / BUSHING FOR PUMP AK39H / H-1" BROWNING o\ N ��_ 1 DRIVE BELT A28 BROWNING 2 3O i \- O/� \ / 1 COUPLING GUARD ABA -CON ABA -CON 3 \ \ I -�, 34 h 20 1 Starter-NEMA 7-9 EXPLOSION PROOF ENCLOSURE WITH Size "1" STARTER MOTOR, KEYED PUMP ON -OFF - 27 SWITCH & (KEYED DEADMAN OVERRIDE SWITCH) 14DUE32HAA4 SEIMENS ��� 21 1 FILTER VESSEL El 1581, 6TH EDTION FILTER SEPERATOR. CATEGORY-M TYPE-S. HCS-333-1436 FACET (\�5° ii �/ 1 3 O�, 3 CM SERIES COALESCER CARTRIDGES El 1581 6th EDTION CATEGORY-M CM-33S6-5 FACET f .pj� \ 1 36 SM SERIES SEPARATOR CARTRIDGE El 1581 6th EDTION CATEGORY-M SM-436FB-5 FACET `U-1 o n I �-'\ ; � � o / �" � %�^~\ ��-•' 1 i ARMSTRONG MODEL 21AR, AIR VENT, CAST IRON, 208P51 21AR ARMSTRONG � 17 3 \) (25 24" MANWAY 1 AIR ELIMINATOR CHECK VALVE 3J4" MNPT (NOT SHOWN) GTP-2916-10 Gammon -- - -- 2" CONDUIT ; !16�F� �\ ,\ / / -/ %° i` 1 SPR. RETURN 3/4" BALL VALVE STAINLESS 22-061-41 LANCE \ /� 1 ADAPTOR-3/4" (NOTSHOWN) PART3/4"A PT COUPLING / \` 1 DUSTCAP-3/4 NOT SHOWN PART34"V PT COUPLING 22 J�'" \\ \! 0 � X /� � \��\ ��� 1 VALVE, PRESSURE RELIEF, STEEL 3CRVOOF 75P51 HYDROSEAL Cy 1203 / �l� 1 WATER SWITCH FLOAT (NOT SHOWN) LS-5000-SB FPI 10 22 1 DIFFERENTIAL PRESSURE GAUGE GTP-534-PB-30A Gammon Q �.\ \• \ / S - --{ 20 ) % - 1 PRESSURE GAUGE 4", LM, 160PSi, L/F, 1/4NPT, SS 9699257 WIKA i 1 Z \ 12' MINIMUM \ \ \ \ ! / i i �` -� 3 J 23 1 HOSE REEL,115V, ALUM INTERN TOP RIGHT W/AUX CRANK EP3905-23-12-10FF REELCRAFT / I 3 COUPLINGVICTAULIC2" (NOTSHOWN) 772" Victaulic \� �� 1 AIRCRAFT FUELING NOZZLE 1 295SAC-0156 DPW fuel Y �I •�\ • � � g; � / � --.�\ �� if ��� � 1 HOSE EI-1529, AVIATION FUELING HOSE, COUPLER MXM, W, CERT SIZE: 1.0" X 75' EAGLE FLIGHT \ / `�� _,\ '(l 24 1 BULK LOADING COUPLER. 2.0" NPT INLET 1712D-AL20 OPW Eng \ J / \ I L c 1 DUST PLUG 2.5", BULK LOADING COUPLER (NOTSHOWN) PART 25W PT COUPLING 1 SECURITY CHAIN STAINLESS, DUST PLUG (NOT SHOWN) S-52 PT COUPLING 111��' ( \ �41 f ` ' � �' ! �, � / \ � 1 ;SWIVEL-2" NPT, ALUMINUM 3640-0203 DPW Eng HOSE EI-1529, COUPLER MXM, W/CERT SIZE: 2.0" X 12' EAGLE FLIGHT - - - 24 fI \ \ 1 i 25 1 3" ALUMINUM FLOATING & SUCTION ASSEMBLY ABA -CON •' ;SWIVEL-3" ALUM FOR SUBMERGE SERVICE (DOUBLE) FLANGED 3640-F10302 DPW ENG. 3 5 \ 1 ADAPTER-2" ALUMINUM (FLOATING SUCTION TEST CABLE PORT) PART 20F PT COUPLING --/ 1 DUST CAP-2" LOCKING (FLOATING SUCTION TEST CABLE PORT LIQUID TIGHT CAP) PART 20V1 PT COUPLING 26 1 TOTAL CONTROLS (SPA). METER, WITH REGISTER 1/10 USG, 100:1 PULSAR, AIR ELIMINATORJSTRAINER, ( 68215SPA4AT3 TOTAL CONTROL / O� \ i" �\ '\ �\'\ ---{ 14 f CHECK VALVE (CERTIFIED FOR PUBLIC RESALE) ( 700-7000V20SS BACK ELEVATION 23 )- `4 ��%' _ �_ --� 26 2`t J\\-- 27 1 120VAC DEAD MAN / RELAY WATER CONTROL SYSTEM, FLOAT SWITCH, MINI-DEADMAN, 25' COIL CORD STP-1750 3-1 2 1-1-1-3-3-2 Gammon SCALE: 1:60 FRONT ELEVATION'-� 1/ O TOP VIEW 28 1 3" VALVE EXTERNAL EMERGENCY VALVE, FLANGED, 165° FUSIBLE LINK VALVE 346DI-0300 AV Morrison 29 1 REEL, GROUND 75' SPR/REWIND HGR-50 17-50 Hannay _ SCALE. 1:60 1 CABLE, CLEAR VINYL COVERED (NOT SHOWN) GTP-1093 Gammon SCALE: 1:100 DATE: 6/1$/2021 - � \j--�\ � -`� � .�\` 1 1 STOP BALL (NOT SHOWN) GTP-1486 Gammon � 34 � ,--�\ 3 { \ 30 /�^\I (/ \ 1 CABLE STOP BALL CLAMP (NOTSHOWN) GTP-1487 Gammon _-_. 11� % 5 ) GTP-1101 Gammon I 1 'CLAMP HEAVY DUTY, AIR FORCE TYPE REVISIONS \ \ I �6 30 1 RIGHT SIDE MOUNTED LADDER J DECK PLATFORM (PAINTED OSHA YELLOW) ABA-SMCW-120 ABA -CON 42� 42 \� 17 \ 31 1 GAUGE STICK 12' (NOT SHOWN) (MANUAL GAUGE STICK) 12-Jan BAGBY / \ i / \� 32 2 VALVE SWING CHECK 3/4" STAINLESS 46635K65 MCMASTER DATE DESCRIPTION. 0 34 1 INVENTORY PROBE / INSTALLATION KIT ( B4K2 / PK4-RM1 PNEUMERCATOR \ ; - r-HANGE35 1 20 GALLON ALUMINUM SUMP FUEL RECOVERY UNIT 20G-AL-SR ABA -CON 7/29/2021 j \\ ABE EDDUNLABE UNLABELED PARMISLABELIED TS. FIXED'; VISUAL STYLES. UPDATED DOM { \ \ �� I �', ! 1 SPR. RETURN 1/2" BALL VALVE STAINLESS (RETURN TO STORAGE VALVE) 22-041-41 LANCE - �� 13� ( 1 S I /� �- I 4 I 1 BALL VALVE 1/2" LOCKABLE STAINLESS (WASTE SUMP VALVE) 122-041-11 LANCE 7/29/2021 %2 '•, TO BUTTERFLY VALVE SWITCHED BYPASS CHECK VALVE \ 3 U ( I 1 VALVE SWING CHECK 3/4„ STAINLESS 46635K65 MCMASTER / ^�7\\l ��� I I 36 1 ST-15-115-ELK / 07720 / \ UPDATED BOM. UPDATED 120.� /�\ \ ( i /� 2 / ( 0 r 1203 ST-15 SINGLE POINT OVERFILL PREVENTION CONTROLLER, SC-6A SCULCON JUCTION BOX, PLUG &CABLE SCULLY 9/15/2021 3 PLACARDS \ - I I SC-6A / 08156 L \ 25 ii it I ( 5 �� y I I C 37 1 1" ELECTRICAL POWER CONDUIT STUB 10 �\ NONSMOKING JET -A FLAMMABLE J I' NO SMOKING JET -A FLAMMABLE " / u 20 N I I 38 1 3/4" ELECTRICAL POWER CONDUIT STUB / C I 39 1 1/2" INTRINSICALLY SAFE SHIELDED WIRING CONDUIT STUB - ��\ J 3 6 } I I 40 1 SELF -SERVE CONTROL VALVE, TWO STAGE, 1.5"NPT, 115VAC SOLENOID, N/C, W/VITON SEALS, COILS INCLUDED, 304 STAINLESS STEEL BODY 108665 BENNETT -' �� x. \ �{ ( I I� 41 1 TOTAL CONTROLS (SPA). METER WITH VEEDER-ROOT MECHANICAL REGISTER, 1/1 USG 70030SPA2AG TOTAL CONTROLS EtJ SCALE:VARI ES 42 1 EXPLOSION PROOF CANOPY LIGHT FIXTURE WITH ON -OFF SWITCH EM1120X2G KILLARK ,�, � i I tl I i � 43 1 VALVE, PRESSURE RELIEF, DUCTILE STEEL, 100PS1 078DI-0300 AV Morrison (J ) N J I 45 1 PUMP BY-PASS VALVE, STEEL, 20-40 PSI BV2A BLACKMER C� RAW N BY: n A 46 PRODUCT PIPING 1.0" AND LARGER, SCH10 304/304L STAINLESS STEEL, ASTM SA312 USA �'\/I 6" 4" 4" 6" r 6'_6" 6' �� 47 PRODUCT PIPING 1.0" AND SMALLER, SCH40 304/304L STAINLESS STEEL, ASTM SA312 ( USA 26 -6 20'-6" 48 FLANGES 304/304L S/S, 150# RAISED FACE SJO FLANGE, ASTM SA182. ELBOW 90-45 REDUCERS, SCH10 APPROVED BY. LEFT ELEVATION RIGHT E L E VAT I O N 304/304L 5/5, ASTM SA403W PW. FLANGE GASKETS-C4401 1/16" NON -ASBESTOS. BOLTS ASTM A193 GRADE USA Q 5 STAINLESS STEEL. NUTS - HEXAGON ASTM A193 GRADE S. SCALE: 1. 80 SCALE: 1 . V 0 49 INSTRUMENT TUBING: ASTM A269, A35 WALL, 304 STAINLESS. COMPRESSION FITTINGS: DKAOK TUBE USA A FITTINGS 316 STAINLESS STEEL, THREAD TAPE MIL-T 27730A. CLIENT: ZEPHYRHILL3 MUNICIPAL AIRPORT ZEPHYRNILLS, FLORIDA DESIGN TEAM TITLE: • ADAMS TANS( AND LIFT INC. 4568 131 ST AVE N CLEARWATER, FL 33762 727-540-0931 NO. DATE REVISION DESCRIPTION This item has been digitally signed and sealed by Soumya Chakrabarti, PE, on date shown. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. ��11111111111///I U HA Q • �pJ • .......... * ; No. 66380 STATE OF a.�` OR0)P'� '• NM- I� Iry�1�Y\ ���J�I SM _ O A CHAKRABARTI FL. REG # 66380 TANK AND PIPING PLANS & DETAILS SITE DESIGNATIONS: FUEL FARM REPLACEMiENT SCALE: AS NOTED JOB # 01 DATE: 09-23-2021 DESIGNED BY: DRAWN BY: SS FILE NAME: CHECKED BY: DRAWING TITLE: AVCAW TANK AND EU I PMLNT SHEET NO: TA-3 I !L ! 1 ❑ L nw ! _ — L -.. FLU_ H 2' CONDUIT TO SECONDARY TANK 14GA. 14 GA. EARTH GROUND (BY OTHERS) D � • WARNING! 1. 3 PHASE CIRCUIT TO PUMP, IF ANY HIGH LEG, CONNECT TO L3. 2. THERE MAST BE AN fNDIVIDUAL BREAKER AND CIRCUIT PER HOSE REEL. 3. THE CONTROL, HOSE REEL, VESSEL SUMP HEATER CIRCUIT, AND OPTIONAL EQUIPMENT (IF EQUIPPED) CANNOT HE CONNECTED TO THE PUMP MOTOR CIRCUIT IN ANY WAY! DOING SO WILL VOID WARRANTY. 4. ANY MODIFICATIONS TO ELECTRICAL SYSTEM WITHOUT WRITTEN APPROVAL WILL VOID WARRANTY. TANK ANTI SIPHON VALVE BOARD INSIDE THE EFG-80001 GREENLEAF EFG-8000A LEVEL ALARM GAUGE COPPER CLAD GROUND STUD JUNCTION BC DEADMAN HANDLE SO CORD JET -A EQUIPMENT AREA STARTER ENCLOSURE HDA'LUN AVIATION SERVICES ABA -CON INC. P.O. BOX 308 TITUSVILLE, FL 32781 • PHONE: (321) 567-4967 FAX: (321) 607 6805 WEB: www.aba-con.com PROPRIETARY AND CONFIDENTIAL The information contained in this drawing is the sole property of ABA -CON Aviation Services_ Any reproducton in part or as a whole is prohibited without written permission of ABA -CON Aviation Services.. PROJECT CONTRACTOR: ADAMS TANK & LIFT, INC. 4568 131 STAVE NORTH CLEARWATER, FL 33762 JOB NUMBER: 2105 DRAWING NUMBER: 2105-40 UN/UI-I- avvi i Uri SWITCH Lei Q NEUTRALy FILTER SUMP = L.I.. LIGHT CIRCUIT `../ -' a" CONDUIT STUB FUTURE SELF -SERVE BLK GAMMON BLK 8 GA. L1 1 120VAC W GTP 9330-1 LIGHT FIXTURE WHT DISPENSING CABINET 20 FULL LOAD AMP _I Q BREAKER REQUIRED W SL Z Uj BLK 14GA. Z U U) WHT 14GA. W SCULLY ST-15E(LK) CONDUIT - INTRINSICALLY SAFE WIRINI AGGUKUINU I U LUAU, VUL I AUi=, AND O O a DISTANCE FROM POWER SUPPLY SATE: 6/18/2021 REVISIONS DATE I DESCRIPTION 'APPROVED BY: SR CLIENT: ZEPHYRHILLS MU -MI C I PAL AIRPORT ZEPHYRHILLS, FLORIDA DESIGN TEAM TITLE: Tak w ADAMS TANK AND LIFT INC. 4568 131 ST AVE N CLEARWATER, FL 33762 727-540-0931 NO. DATE REVISION DESCRIPTION This item has been digitally signed and sealed by Soumya Chakrabarti, PE, on date shown. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. C HArKp / 6380 TE OF ti,, � 1//�tNA`��`,,,,,. 1 SOUMYA CHAKRABARTI FL. REG # 66380 TANK AND PIPING PLANS & DETAILS SITE DESIGNATIONS: FUSEL FARM REPLACEMENT SCALE: AS NOTED JOB # 01 DATE: 09-23-2021 DESIGNED BY: DRAWN BY: SS FILE NAME: CHECKED BY: DRAWING TITLE: JET -A TANK ELECTRICAL SCHEMATIC SHEET NO: TA-4 I _ 1 1 �. 1 I _- i— -I __ -.1'' _ — - _ - I. I I I . _ _ -11 V ' II'' 111 Tl '! ' e 'r Ic1 --pr_ r PT 11P - — '1 11 l'1 "I I �'1fr q. •'I' ' .e! ! 11� _ 'll I I I _ I _ I 1 i • 111_1WW1111' F- No TANK EART (BY O � • WARNING . 1. 3 PHASE CIRCUIT TO PUMP. IF ANY HIGH LEG, CONNECT TO L3. 1 THERE MUST BE AN INDIVIDUAL BREAKER AND CIRCUIT PER HOSE REEL. 3. THE CONTROL, HOSE REEL, VESSEL SUMP HEATER CIRCUIT, AND OPTIONAL EQUIPMENT (IF EQUIPPED) CANNOT BE CONNECTED TO THE PUMP MOTOR CIRCUIT IN ANY WAY! DOING SO WILL VOID WARRANTY. 4. ANY MODIFICATIONS TO ELECTRICAL SYSTEM WITHOUT WRITTEN APPROVAL WVILL VOID WARRANTY. AVGAS EQUIPMENT AREA 1 2 3 4 5 _H_N . G_C_NO TB-1 %FF111 ro !01O ( )) SCULLY ST-15E(LK) CONDUIT - INTRINSICALLY SAFE WIRINI STARTER ENCLOSURE NHT 12GA. 3LK 8GA. 3LK 8GA. 3LK 8GA. NHT 12GA. NHT 12GA. 3LK 8GA. FIELD WIRING TO BE SIZED BY ELECTRICIAN ACCORDING TO LOAD, VOLTAGE, AND DISTANCE FROM POWER SUPPLY SUGGESTED -OP BREAKER PANEL (BY OTHERS) SHUNT TRIP DISCONNECTS ENTIRE PANEL It AVGAS PUMP CIRCUIT L2 1 11:1 230VAC 21 ACTUAL FULL LOAD L3 AMPS JET -A CONT CIRCUIT L1!I 1 � 120VAC 20 FULL LOAD AMP BREAKER REQUIRED 0 HOSE REEL L1 1 + 120VAC 20 FULL LOAD AMPS BREAKER REQUIRED NEUTRAL LIGHT CIRCUIT 1 � 120VAC - 20 FULL LOAD AMP BREAKER REQUIRED COMPUTER CIRCUIT 10 120VAC 20 FULL LOAD AMPS BREAKER REQUIRED moi% � I AABA-CON- VIATION SERVICES ABA -CON INC. P.O. BOX 308 TITUSVILLE, FL 32781 PHONE: (321) 567-4967 FAX: (321) 607 6805 WEB: www.aba-con.com PROPRIETARY AND CONFIDENTIAL The information contained in this drawing is the sole property of ABA -CON Aviation Services. Any reproducton in part or as a whole is prohibited without written permission of ABA -CON Aviation Services. PROJECT CONTRACTOR: ADAMS TANK & LIFT, INC. 4568 131 STAVE NORTH CLEARWATER, FL 33762 JOB NUMBER: 2105 DRAWING NUMBER: 2105-50 DATE: 6/18/2021 REVISIONS DATE I DESCRIPTION SCALE:XX:XX DRATNI i 7 KM APPR*VED BY: SR CLIENT: ZEPHYRHILLS MUNICIPAL AIRPORT ZEPHYRHILLS, FLORIDA DESIGN TEAM TITLE: Utk # • I 0 ADAMS TANK AND LIFT INC. 4568 131 ST AVE N CLEARWATER, FL 33762 727-540-0931 NO. DATE REVISION DESCRIPTION This item has been digitally signed and sealed by Soumya Chakrabarti, PE, on date shown. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. C HA K,pq'%'��, ••�\ r E N SF• ":9q�%� _ * No. 66380 _0 STATE OF SS�ONAL ��G``��• /11111111111\ SOUMYA CHAKRABARTI FL. REG # 66380 TANK AND PIMPING PLANS & DETAILS SITE DESIGNATIONS: FUEL FARM REPLACEMENT - SCALE: AS NOTED JOB # 01 DATE: 09-23-2021 DESIGNED BY: DRAWN BY: SS FILE NAME: CHECKED BY: DRAWING TITLE: AVGAS TANK ELECTRICAL SCHEMATIC SHEETNO; TA-5 I 1 P 1 I if 1 1II I 1 I11 II 1 7 '„ I, it •I 1, 1 ,s i 1 11 1 I 1' '_ I I 1 11 1 I 1 1 1 1 1 1 1 11 1 11VW lI Flew v I - RS-232 COMMUNICATIONS - RS-485 TO PCO PERIPHERALS - TELEPHONE LINE DRY CONTACT SWITCH OUTPUT NON-I.S. DRY CONTACT INPUT TO EARTH GROUND 0 � • WARNING. 1. 3 PHASE CIRCUIT TO PUMP. IF ANY HIGH LEG, CONNECT TO L3. 2. THERE MUST BE AN INDIVIDUAL BREAKER AND CIRCUIT PER HOSE REEL. 3. THE CONTROL, HOSE REEL, VESSEL SUMP HEATER CIRCUIT, AND OPTIONAL EQUIPMENT (IF EQUIPPED) CANNOT BE CONNECTED TO THE PUMP MOTOR CIRCUIT IN ANY WAY! DOING SO WILL VOID WARRANTY. 4. ANY MODIFICATIONS TO ELECTRICAL SYSTEM WITHOUT WRITTEN APPROVAL WILL VOID WARRANTY. TMS-2000 PD 1230 [ WHT 12 GA. RED 8 GA. ITEM CITY I DESCRIPTION PART NUMBER MANUFACTURER 1 1 Pneumercator TMS2000-43-30-0 NEMA 4X console with display, printer w/autowinder, network interface card, (NIC-Ethernet) card, internal ethernet interface card TMS2000-43-30-0 Pneumercator 2 2 AST INVENTORY PROBE, IOFTDIA. MP45OS-124-25 Pneumercator 3 1 FLOAT KIT -AVGAS B4K1 Pneumercator 4 1 FLOAT KIT - JET B4K2 Pneumercator 5 2 4" RISER Mt INSTALL LOCKABLE KIT PK4-RM1 Pneumercator 6 2 NON DISCRIMINATING LOCKABLE KIT LS60OLDBN-1 Pneumercator 7 2 2" RISER MOUNT INSTALL KIT SK2-RM1 Pneumercator 8 1 PROBE/SENSOR MAIN PANEL 36-WIRE PROTECTION PD1230 Pneumercator 9 2 PROBE/SENSOR IN 6-WIRE PD230 Pneumercator 10 3 1 24VDC PROTECTION CARTRIDGE 3-PACK PM324-3 Pneumercator PD230 PNEUMERCATER CIRCUIT L1 X � 120VAC X FULL LOAD AMP BREAKER REQUIRED PD230 Z �— * 03.m �m U NEUTRAL / 1 AVIATION SERVICES ABA -CON INC. P.O. BOX 308 TITUSVILLE, FL 32781 PHONE: (321) 567-4967 FAX: (321) 607 6805 WEB: www.aba-con.com PROPRIETARY AND CONFIDENTIAL The information contained in this drawing is the sole property of ABA -CON Aviation Services. Any reproducton in part or as a whole is prohibited without written permission of ABA -CON Aviation Services. ROJECT CONTRACTOR: ADAMS TANK & LIFT, INC. 4568 131 STAVE NORTH CLEARWATER, FL 33762 JOB NUMBER: 2105 DRAWING NUMBER: 2105-60 I cQ G W I r0�� V ) Of O Q U W W z 0— SATE: 6/18/2021 REVISIONS DATE I DESCRIPTION SCALE:XX:XX DRAWN BY: KM APPROVED BY: AB CLIENT: ZEPHYRHILLS MUNICIPAL AIRPORT ZEPHYRHILLS, FLORIDA DESIGN TEAM TITLE: live s ADAMS TANK AND LIFT INC. 4568 131 ST AVE N CLEARWATER, FL 33762 727-540-0931 NO. DATE REVISION DESCRIPTION This item has been digitally signed and sealed by Soumya Chakrabarti, PE, on date shown. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. \\,,,,,IIIIIIII//IIII y.. C HA KR��''' . 1�9 % _ * No. 6 380 TATE OF f/0 SOUMYA CHAKRABARTI FL. REG # 66380 TANK AND PIPING PLANS & DETAILS SITE DESIGNATIONS: FUEL FARM REPLACEMENT SCALE: AS NOTED JOB # 01 DATE: 09-23-2021 DESIGNED BY: DRAWN BY: SS FILE NAME: CHECKED BY: DRAWING TITLE: PNE U M RCATOIR SCHEMATIC SHEET NO: TA-6 JET -A TANK EQUIPMENT AREA LEGEND FI LI SR FLOW LEVEL RC TUBING INDICATOR INDICATOR FIRE UPDRAFT FILTER VESSEL 4 VALVE RELAX SUMP VENT DIFFERENTIAL 3" TUBING CHAMBER RECOVERY PRESSURE $ 2" TUBING MS [�D 3n PIPING PRESSURE AIR SPRING PRESSURE FILTER VESSEL 4 RELIEF RELIEF - - CLOSED BALL MILLIPORE VACUUM WATER DETECTOR 2" PIPE VALVE SAMPLE VENT PROBE 3" PIPE F vs g FIR _ CONDUIT/ �' x VISUAL EMERGENCY FUEL HOSE WIRING FILTER FLOW FUEL PUMP VESSEL METER HOSE SAMPLER VENT HOSE REEL FUELING NOZZLE BALL LINE ORIFICE FLOAT HAND VAPOR FILTER VALVE STRAINER VALVE PUMP RECOVERY SUMP ADAPTER HEATER BUTTERFLY CHECK DIAPHRAGM ELECTRICALLY CAMLOK PRESSURE BYPASS VACUUM VALVE VALVE VALVE ACTUATED GAUGE VALVE GAUGE VALVE ABA -CON AVIATION SERVICES ABA -CON INC. P.O. BOX 308 TITUSVILLE, FL 32781 PHONE: (321) 567-4967 FAX: (321) 607 6805 WEB: www.aba-con.com PROPRIETARY AND CONFIDENTIAL The information contained in this drawing is the sole property of ABA -CON Aviation Services. Any reproducton in part or as a whole is rohibited without written permission of ABA -CON Aviation Services. PROJECT CONTRACTOR: ADAMS TANK & LIFT, INC. 4568 131 STAVE NORTH CLEARWATER, FL 33762 JOB NUMBER: 2105 DRAWING NUMBER: 2105-70 .0 06 w U) Ir—n r� v V z I— Q I"'-- W 3 W J 1— F— ATE: 6/18/2021 REVISIONS DATE I DESCRIPTION CHANGED TANK FILL AND 17/29/20211� SUCTION BALL VALVES TO BUTTERFLY VALVES CALE:XX:XX RAWN BY: KM APPROVED BY: >1 CLIENT: ZEPHYRHILLS MUNICIPAL AIRPORT ZEPHYRHILLS, FLORIDA DESIGN TEAM TITLE: W&W 1"k & f� • Eft ADAMS TANK AND LIFT INC. 4568 131 ST AVE N CLEARWATER, FL 33762 727-540-0931 NO. DATE REVISION DESCRIPTION This item has been digitally signed and sealed by Soumya Chakrabarti, PE, on date shown. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. \``\111111111111/l////// CHA A * ; No. 66380 .p • STATE OF 4 OR SOUMYA CHAKRABARTI FL. REG # 66380 TANK AND PIPING PLANS A DETAILS SITE DESIGNATIONS: FUEL FARM REPLACEMENT SCALE: AS NOTED JOB # 01 DATE: 09-23-2021 DESIGNED BY: DRAWN BY: SS FILE NAME: CHECKED BY: DRAWING TITLE: JET -A TANK SYSTEM P& ID SHEET NO: TA-7 I I I fir, Ell 'f II tll'1! IAA 11 I'I_ N 1 11 II T Z I I 'I I _ 11 I I'I '�" hIRI yl !1 I 'fr _ 1, 11 1I AVGAS TANK EQUIPMENT AREA TRANSPORT SHUTOFF VALVE STR C. V. y 3" ELECTRICALLY PIPE ACTUATED VALVE T HR FUEL HOSE HOSE REEL FUELING NOZZLE 0 M rZ C C T T I x 3" PIPE SR *NOTE: 1 PER SYSTEM Q _ VAPOR 211 RECOVERY PIPE ADAPTER lie 2 PR - TUBING FDP FILTER 3,1 +C. V. PIPE MS F MS FLOW METER FLOW METER 1" X 75' HOSE 2" X 12' HOSE LEGEND PUMP 3/4" �& PIPE AIRCRAFT AIRPORT REFUELER 3/4" PIPE 2„ PIPE 3" PIPE ' 3" PIP®E I I FI LI --t%- SR FLOW LEVEL RC 1" TUBING INDICATOR INDICATOR FIRE UPDRAFT FILTER VESSEL 4 VALVE RELAX SUMP i VENT DIFFERENTIAL 3n TUBING CHAMBER RECOVERY PRESSURE $ 2" TUBING PIPING PRESSURE AIR SPRING PRESSURE FILTER VESSEL 4 RELIEF RELIEF CLOSED BALL MILLIPORE VACUUM WATER DETECTOR 2" PIPE VALVE SAMPLE VENT PROBE 3" PIPE F FS g HR CONDUIT/ FILTER FLOW FUEL PUMP VISUAL EMERGENCY FUEL HOSE WIRING VESSEL METER HOSE SAMPLER VENT HOSE REEL FUELING NOZZLE BALL LINE ORIFICE FLOAT HAND VAPOR FILTER VALVE STRAINER VALVE PUMP RECOVERY SUMP ADAPTER HEATER BUTTERFLY CHECK DIAPHRAGM ELECTRICALLY CAMLOK PRESSURE BYPASS VACUUM VALVE VALVE VALVE ACTUATED GAUGE VALVE GAUGE VALVE AVGAS UL-142 DOUBLE WALL TANK TANK LEVEL NOTE: GAUGE 2PER LI SYSTEM -�•-' as 1 C. V. 95% CAPACITY -�- FLOAT VALVE i 3/8" TUBE I 1 i 1 i OVERFILL VALVE PRE -CHECK A 90% ALARM TANK 95% FILL SHUTOFF SHUTOFF VALVE VALVE PRESSURE SPRING CLOSED VACUUM BALL VALVE VENT 3/4" PIPE FLOATING SUCTION I PROBE, FLOAT KIT, 4" RISER KIT PNEUMERCATOR MP4505-124-25/B4K2/PK4-RM1 INTERSTITIAL SPACE LEAK SENSOR PNEUMERCATOR LS60OLDBN-1 / SK2 - RM1 3" PIPE LOCKABLE BALL VALVE HAND I PUMP ANTI -SIPHON VALVE T FIRE VALVE CyV. TANK SUCTION SHUT-OFF VALVE OorABA -CON AVIAITION SERVICESII ABA -CON INC. P.O. BOX 308 TITUSVILLE, FL 32781 PHONE: (321) 567-4967 FAX: (321) 607 6805 WEB: www.aba-con.com PROPRIETARY AND CONFIDENTIAL The information contained in this drawing is the sole property of ABA -CON Aviation Services. Any reproducton in part or as a whole is prohibited without written permission of ABA -CON Aviation Services. 'ROJ ECT CONTRACTOR: ADAMS TANK & LIFT, INC. 4568 131 STAVE NORTH CLEARWATER, FL 33762 JOB NUMBER: 2105 DRAWING NUMBER: 2105-80 7 06 W I— U) z Q U) Q Q W DATE: 6/18/2021 REVISIONS DATE DESCRIPTION CHANGED TANK FILL AND SUCTION 7/29/ BALL VALVES TO BUTTERFLY / 202 1 1 VALVES AND BYPASS CHECK %JAI UP: T(1 RI ITTCACI V UAI VC CALE:XX:XX CLIENT: ZEPHYRHILLS MUNICIPAL AIRPORT ZEPHYRHILLS, FLORIDA DESIGN TEAM TITLE: • I a ADAMS TANK AND LIFT INC. 4568 131 ST AVE N CLEARWATER, FL 33762 727-540-0931 NO. DATE REVISION DESCRIPTION This item has been digitally signed and sealed by Soumya Chakrabarti, PE, on date shown. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. C HA /(p" i = N . 66380 .� ATE OF S/ONA� ����``�, 0 111111110� \ SOUMYA CHAKRABARTI FL. REG # 66380 TANK AND PIPING PLANS & DETAILS SITE DESIGNATIONS: FUEL FARM REPLACEMENT SCALE: AS NOTED JOB # 01 DATE: 09-23-2021 DESIGNED BY: DRAWN BY: SS FILE NAME: CHECKED BY: DRAWING TITLE: AVGAS TANK SYSTEM P& ID SHEET NO: TA-8