ENGINEER'S NOTES
ALL WORK TO BE DONE ACCORDING TO FLORIDA BUILDING CODES,
BUILDINGS OR STRUCTURES SHALL CONFORM TO
2017 FBC 6TH, EDITION BUILDING.
AN ADDITION TO A BUILDING OR STRUCTURE SHALL COMPLY WITH THE FBC'S AS
FOR NEW CONSTRUCTION WITH❑UT REQUIRING THE EXISTING BUILDING OR STRUCTURE
TO COMPLY WITH ANY REQUIREMENTS OF THOSE CODES OR OF THESE PROVISIONS
EXCEPT AS REQUIRED BY CHAPTER 10. WHERE AN ADDITION IMPACTS THE EXISTING
BUILDING OR STRUCTURE, THAT P❑RTI❑N SHALL COMPLY WITH THIS CODE,
CREATION OR EXTENSION OF NONCONFORMITY. AN ADDITION SHALL NOT CREATE OR
EXTEND ANY NONCONFORMITY IN THE EXISTING BUILDING TO WHICH THE ADDITION IS
BEING MADE WITH REGARD TO ACCESSIBILITY, STRUCTURAL STRENGTH, FIRE SAFETY,
MEANS OF EGRESS, OR THE CAPACITY OF MECHANICAL, PLUMBING, OR ELECTRICAL
SYSTEMS.
ASSUMED SOIL BEARING CAPACITY TO BE 2000 PSF. S❑IL CAPACITY TO BE VERIFIED
BY CONTRACTOR PRIOR TO CONSTRUCTION. INFORM ENGINEER OF VARIATIONS.
FOOTINGS TO BE EXCAVATED TO CLEAN SOIL, FREE OF VEGETATION AND
DELETERIOUS MATTER, CONCRETE SHALL BE PLACED ON AN UNDISTURBED BASE.
CONCRETE 1
MINIMUM COMPRESSIVE CONCRETE STRENGTH TO BE 2500 PSI IN 28 DAYS. ALL
CONCRETE SHALL BE 'READY MIXED' AND IN ACCORDANCE WITH A.S.T.M.
SPECIFICATION C-94.
SLAB ON FILL 1
INTERIOR CONCRETE SLABS POURED ON FILL TO BE POURED OVER WATERPROOF
MEMBRANES, ALL SLABS TO BE REINFORCED WITH 6X6 10/10 WELDED WIRE MESH.
LUMBER 1
1. STORE LUMBER OFF GROUND. KEEP WELL VENTILATED AND COVERED.
2. CURRENT EDITION, ASSOCIATION GRADING RULES GOVERN.
3. ALL LUMBER SHALL BEAR GRADE MARK OF AN ASIC BARD OF REVIEW AGENCY,
4. ANY SPECIES ALLOWED UNLESS OTHERWISE NOTED.
5. SIZES ARE N❑MINAL. ACTUAL SIZES SHALL CONFORM T❑ AMERICAN
LUMBER STANDARD PS 20-70.
6. MOISTURE CONTENT OF LUMBER 2' OR LESS IN THICKNESS SHALL BE
19% OR LESS AT THE TIME OF INSTALLATION.
STRUCTURAL LUMBER TO HAVE 1120 PSI FIBER STRESS IN CONFORMANCE TO
AMERICAN INSTITUTE OF TIMBER CONSTRUCTION (AITC) SPECIFICATIONS. ALL
LUMBER AGAINST MASONRY OR CONCRETE TO BE PRESSURE TREATED.
TERMITE TREATING 1
SOIL BELOW STRUCTURE TO BE TERMITE TREATED TO A DISTANCE OF 5'-0'
BEYOND THE PERIMETER LINES OF THE BUILDING.
ALL STEEL SHALL BE 40 KSI WITH A MINIMUM CLEAR COVER OF 3' AGAINST
SOIL, AND SHALL HAVE A MINIMUM LAP OF 40 TIMES THE DIAMETER OF THE REBAR,
HEADERS SHALL BE DBL, 2X MEMBERS AND LAMINATED W/1/2' PLYWOOD
GLUED W/CONSTRUCTION ADHESIVE AND NAILED W/#16D COMMONS 16' O.C.
ALL FASTENERS SHALL COMPLY WITH THE DESIGN LOADS.
CONTRACTOR SHALL HAVE MANUFACTURERS SPECIFICATIONS (CUT SHEETS) ON SITE
AT THE TIME OF INSPECTION, FOR REVIEW BY THE BUILDING INSPECTOR,
TO MEET LOADS AS INDICATED.
DOORS & WINDOWS
ENGINEERS N❑TES1
DESIGN LOADS,
A. WIND LOADS, PERT
1) RISK CATEGORY Il - PER (TABLE 1604.5/TABLE 1.5-1)
2) EXP. 'B', PER TABLE 1609.4.5/SECTION 26.7.5
3) THE BASIC ULTIMATE DESIGN WIND SPEED, V (ULT) = 140 MPH ult 3 SEC GUST
4) NOMINAL DESIGN WIND SPEED, V (ASD) = 110 MPH asd 3 SEC GUST
5) INTERNAL PRESSURE COOFFICIENT, GCPI = .18 ENCLOSED PER TABLE 26.11.1
6) COMP. & CLADDING PRESSURES PER TABLE R301.2(2), UNLESS SPECIFICALLY LABELED ON PLAN
B. LIVE LOADS, PER 1607, INCLUSIVE BUT NOT LIMITED TO,
1) ROOF LIVE LOAD = 20 PSF
2) FLOOR LIVE LOAD = 40 PSF
3) UNINHABITTABLE ATTIC LIVE LOAD = 10 PSF
4) HABITTABLE ATTIC LIVE LOAD = 20 PSF
C. DEAD LOADS, PER 1606, INCLUSIVE BUT NOT LIMITED TO,
1) ROOF DEAD LOAD (TOP CHORD) = 25 PSF
2) ROOF DEAD LOAD (BOTTOM CHORD) = 10 PSF
3) FLOOR DEAD LOAD = 20 PSF
APPLICABLE CODES,
6TH. EDITION, 2017 FLORIDA BUILDING CODE, BUILDING. PLUMBING,
MECHANICAL, FUEL GAS, AND/OR EXISTING BUILDING
6TH. EDITION, 2017 FLORIDA FIRE PREVENTION CODE (IF APPLICABLE)
2014 NATI❑NAL ELECTRICAL CODE
DATA SUMMARY:
BUILDING USE= SINGLE FAMILY RESIDENCE TYPE R1.
CONSTRUCTION TYPE V, UNPROTECTED, UNSPRINKLED
ALL BEDROOMS REQUIRE AN OUTSIDE WINDOW OR DOOR OPERABLE FROM INSIDE WITHOUT THE
USE OF TOOLS AND PROVIDING A CLEAR OPENING OF NOT LESS THAN 20' WIDTH, 24' IN HEIGHT
& 5,7 SO. FT. IN AREA. THE BOTTOM OF THE OPENING SHALL NOT BE MORE THAN 44' OFF THE
FLOOR AND NO PART OF THE OPERATING MECHANISM SHALL BE PLACED HIGHER THAN 54' A.F.F.
WINDOWS GREATER THAN 72' ABOVE 72' FINISHED GRADE SHALL HAVE THW WINDOW SILL HEIGHT
GREATER THAN 24' OR PROVIDE AN FALL PREVENTIVE DEVICE PER R616.2.
DOORS & WINDOWS
THE OPERATING MECHANISM FOR SINGLE HUNG WINDOWS SHALL BE AT OR NEAR THE SILL.
WINDOWS INDICATED WITH (E) OR EGRESS MUST BE MANUFACTURED TO CONFORM TO THE BLDG,
CODE W/ RESPECT TO MIN. EMERGENCY EGRESS REQUIREMENTS PER N.F.P.A, 101 CHAPTER 24.
ALL GLASS WITHIN 24' OF ANY DOOR, SLIDING GLASS DOOR, ALL GLAZING AT TUB AND
SHOWER ENCLOSURES AND WINDOWS WITHIN LESS THAN 60' AVOVE STAIR LANDINGS OR TREADS SHALL BE
TEMPERED SAFETY GLASS, SEE ADDITIONAL SAFETY GLAZING REQUIREMENTS PER 2010 FBCR R308.
SINGLE SWING EXTERIOR DOORS CONNECTING GARAGE TO LIVING AREAS SHALL BE EQUIPPED WITH
S❑LID WOOD DOORS NOT LESS THAN 1 3/8' (35 MM) THICKNESS, SOLID OR HONEYCOMB CORE
STEEL DOORS NOT LESS THAN 1 3/8' (35 MM) THICK, OR 20 MINUTE FIRE -RATED DOORS,
WHERE MASONRY OPENINGS REQUIRE WOOD FRAMING, TO FIT WINDOW OR DOOR SIZES, PRESSURE
TREATED 2x8 STUDS MAY BE SECURED TO THE MASONRY WITH 1/4' DIA. x 3 1/2' TAPCON SCREWS, 6'
FROM EACH END AND 12' C/C. ADDITI❑NAL FRAMING MEMBERS SHALL BE NAILED TO PRIOR STUD W/
(2) ROWS OF 2d NAILS AT 10' C/C.
GYPSUM WALLBOARD
PR❑VIDE 1/2' NO SAG GYP. BOARD ON ALL CEILINGS. PROVIDE 5/8' TYPE 'X' GYP. BP❑ARD ON ALL
GARAGE CEILINGS WHERE HABITABLE SPACE EXISTS ABOVE, GARAGE SHALL BE SEPARATED FROM THE
RESIDENCE AND IT'S ATTIC AREA BY NO LESS THAN 1/2' GYP, BOARD APPLIED TO THE GARAGE SIDE.
HARDIE BACKER TO BE USED AT ALL SHOWER AND TUB LOCATIONS, UP TO 8' A.F.F.
NON -BEARING INTERIOR PARTITIONS
ALL INTERIOR NON BEARING PARTITIONS SHALL BE 2X4 SPF @ 16' ❑.C. MAX. SPACING WITH SINGLE TOP
AND BOTTOM PLATE W/ 1/2' GYP, DRYWALL EACH SIDE.
-- FLORIDA APPROV= PRODUCTS LNT
Parent Approval Manufacturer Category_
FL15220.6 Plastico, Inc. Exterior Doors
FL15220.5 Plastico, Inc. Exterior Doors
FL15279-R5
FL14911-R8
C1oPaY Building Products Company
Silverline Bldg. Products
Exterior Doors
Windows
FL14911 R9
Sihrcrliae Bldg. ProductsWindows
FL6067-R7
Silverline Bldg. Products _ - Windows
FL16626-1-R3
Tamko Building Products
Roofing
_
FL10674.1Owens
Corning
James Hardie Bldg. Products
Roofing
FL13192.2
-
Panel Walls
FL15272 _
FL11473-R2
side
Simpson Strong -Tie Co.
'Simpson Strong -Tie Co.- -
Simpson Strong -Tie Co.
Simpson Strong -Tie Co._Structural
Simpson Strong -Tie Co. -
Simpson Strong -Tie Co.
Panel Walls
Structural Components
FL11473-R2 _
FL10456.2 R4
Structural Components
Structural Components --
_
FL10456.10-R4
Components
FL10_456.10-R4
Structural Components _ _
FL11473-R2
Structural Components
FL11463.2 -�-Simpson
FL10860.1
Strong -Tie Co.
Simpson Strong -Tie Co. - -
FL10860.2
Simpson Strong -Tie Co.
FL10860.4
Simpson Strong -Tie Co.
FL10860.5
_ -
Simpson Strong -Tie Co.
Structural Components
Structural Components
Structural Components
Structural Components
Structural Components
LSwingin&-Ext. Door -
Swinging Ext. Door Assemblies
Sectional Ext. Door Assemblies
Single -Hung
Single -Hung
_Mullion
Underlayments
Asphalt Shingles
Exterior Siding
Soffits
[TAnchors
Wood Connectors Anchors
Wood Connectors Anchors
Wood Connectors Anchors
Wood Connectors Anchors
Wood Connectors Anchors
Wood Connectors Anchors
Wood Connectors Anchors
Wood Connectors Anchors
Wood Connectors Anchors
# Fkaftet Model # or Name . - Model
Opaque Fiber lass Door Entry Door
ODaaue Fiberslass Door Glazed Fiber
Hardie Plank
HETA20
META
H 2.5 - -- _-
SPl
LSTA12
Aluminum
Aluminum
Door
Fiberglass Reinforced
Cement Board
Aluminum
Embedded Truss Anchor
Embedded Truss Anchor
Strap Ties
H1 ------ - -
ABA66 -
I Tie
PosPos B easeas
ABU66
Po' st Base
AC6 - - -
Post Cap
BC6
Post Can
FBCR 2017 - COMPONENTS AND CLADDING - EXP. 'B'
140 Ult - DESIGN WIND PRESSURE FOR WALLS, DOORS & WINDOWS (N❑MINAL)
COMPONENT
ZONE
EFFECTIVE WIND AREA
WALL
10 SQ. FT,
20 SQ. FT.
50 SQ. FT.
100 SQ. FT,
500 SQ, FT.
WALL
O
+21.2 PSF / -22.0 PSF
+20.2 PSF / -22.0 PSF
+19,0 PSF / -20.0 PSF
+18.0 PSF / -19.0 PSF
+15.8 PSF / -17.0 PSF
WALL
l� l
+21.2 PSF / -28.0 PSF
+20.2 PSF / -26.0 PSF
+19.0 PSF / -23.0 PSF
+18.0 PSF / -22.0 PSF
+15.8 PSF / -17.0 PSF
NOTE,
ALL EXTERIOR DOORS & WINDOWS ASSEMBLIES SHALL SATISFY THE REQUIREMENTS IN FBC 2017. ALL CONNECTIONS TO BUILDING STRUCTURE
SHALL HAVE THE CAPACITY TO WITHSTAND THE PRESSURES INDICATED IN THIS SCHEDULE,
3'-0' FROM THE BUILDING EDGE GOVERNS FOR ZONE 5.
�zv1�0'4 PAS
Ct�� or L � Ff'lC1 A
1WI..D1N�'
M5119%11& MAN CH�CKI.151' MR F0019A PULPING COn� 6fH, W1110N (2011)
1. 51,��PING POOM5 HAVE APFQUAT WINDOW 51Z� ANP PPOMP LOCATION FOP F5CAPE & IT 5CUF (FPC-1d�51P�N11A1, 1?-N0) ,
2, ONP CAfkl/ T0LFf DOOM WITH A 29" MINIMUM CLFAP ACCP55, ON THE LOWWP POOP, P302)
3, HAZAWOU5 6.A55 LOCAT10N5 INPICAt[9, (P[3C-IT5IMNTIAI. P308.4)
4, Af11C ACC�55 LOCAt[2 WITH OPENING nIWN51ON5, ( FPC-M51P�NT1Al. r807)
5, PPOV119� PPOTfCTION PPOM IMPACT" IN GAP a5 POP 12UCTWOPK ANP APPOANCP5,
(FX-W5MNT1& M001, FBC-IutaffiCk 605.15, FBC-M 6A5 ".4)
6, 5fA1P CON5TRUC11ON 12�T'All.5 INPICK1 PPOPK 11TAn/ PISPP PFI.A110N5HIP, HANPPAL 0CAT10N, HANPP&/ 6UAI?VML
WW5, Ate MAXIMUM MN IZAL 5FACING IWICAM7. (FX-M5IMWAL 011.1, IM2.1)
1. PLA5HING 12FTAL5 Af �XVI0P WIN12OW5/ b00P OPPNING5, INSP51�CT1ON5WITN CHIMNEY/ MA5ONPY/ PfC., PPOJPCT1NG
WOOF 1MM, WfRa VM/ POM5/ 5fAR5, WAIV W IR IMT10N5, VMR5, M. (FDC-BUI.nING 101.2.4,
FDC-W5MNfl& R105.4)
8, 5MX 12FSCfOP5 ANP CAkDON MONOXIP7 PFTECT"O6 (FPC-M5112�N11AL P514, P-N
9. PPOVIP� P00P VN%A110N CALClA11ON5, (FX-PP5I1XN11AL P806)
10. PPOVIn� nPT'A11.5 POP PVWI .IN6 GAPAGF OPENING ANI2 PFN�TA110N PMC110N, PPOVIPF MT"&5 POP PMI LING-6APAGf
Ff, WARAW4. (FX-e5MW & RZ502.5, IZ h)
11. PPOVIn� LOCATION OF AU. I�TQWTT GPI/AfI ANP WAfITP00P PtC�PThl8 5, (W-PP5I12�N11AL F3901, �4002)
12. PC OVIP� MINIMUM 15% HI6H-ffFICENCY LICKING, (FPC-�N�PGY CON5WVA110N P404)
REQUIRED ATTIC VENTILATION
AREA OF ATTIC
2396
NET FREE VENTILATION AREA REQ'D.
1/300
REQ'D. VENTILATION ATTIC
2396/300
7.99
VENTILATION AREA x SQ. INCHES PER FOOT (144)
1150
MIN. REQUIRED VENTILATION IN UPPER PORTION OF ATTIC
575
OFF RIDGE VENTILATION AREA 115
SQ. INCH PER VENT
575/115
TOTAL # OF VENTS REQUIRED
5.0
TOTAL # OF VENTS PROVIDED
5
SOFFIT VENTILATION AREA 11.736
SQ, INCH PER PER L.F.
575/11.736
TOTAL LINEAL FT. OF SOFFIT VENTING REQUIRED
49.0
• AREA OF ATTIC IS THE PERIMETER OF THE HOUSE
(EXTERIOR OF WALL TO EXTERIOR OF WALL, NO OVERHANGS
INCLUDED)
DRAWING PAGE INDEX
BF-001-Al
-
ENGINEERING NOTES
BF-001-A2
- FLOOR PLAN
BF-001-A3
- ELEVATIONS
BF-001-A4
- FOUNDATION PLAN
BF-001-A5
- ROOF PLAN
BF-001-A6
- ELECTRICAL PLAN
BF-001-A7
- WALL SECTION & DETAILS
BF-001-A8
- ROOF NAILING
BF-001-A9
- GABLE
TRUSS
DETAILS
I HEREBY CERTIFY THAT I HAVE REVIEWED
THIS PLAN AND FOUND IT TO BE IN
COMPLIANCE WITH ASCE 7-10, & FBC 2017
(6TH. EDITION).
"Twil" I
ENGINEER OF RECORD
David W. Smith P.E.
FLORIDA LICENSE NUMBER: 53608
Plans By:
Larry deMontmoll'n
90 Countiy Club Lane
MnmenY, FL 33860
Phone:(863)397-7525
DATE: 02-08-19
DRAWN BY: L.B.D.
REVISION: I DATE:
R01
RO 2
RO 3
I ;T11fl
PROJECT ADDRESS:
BUITERFIELD INVESTMENTS, INC.
501618th. STREET
ZEPHYRHILLS, FL. 33542
CONTRACTOR:
HOUSE PLAN
NOTES Bi SPECS.
DWG, BF-001-Al REV. 0
NOTE 2:�Vft FLORIDA APPROVED WINDOWS AND DOORS RATED FOR INDICATED DESIGN PRESSURES AND INSTALLED PER DOOR MANUFACTURERS SPECIFICATIONS.
,;R'-n"
QUANTITY
F - 2 ---
1
- 6 -
WINDOW SCHEDULE
CODE
(2)_ 25 SH - --
10d eu TMADinne
25 SH
32/2 SH TEMP/OBS
5H1 MULL
MASONARY /
FRAME
OPENING
------ I. _
WIDTH HEIGHT
WIDTH
HEIGHT
74
63
74 5/8
63
37
37
50 518
_63
37 518
37 5/8
50518
63
26 1 / ]__-
26 -
27.1 /8
26
DESIGN ❑PENING PRESSURES
ENCLOSED BUILDING EXPOSURE "BM
TAG D❑❑R/WIND❑W LISTED ZONE PRESSURE
N❑MINAL SIZE
A
3068 DR.
4
20.2
22
B
2868 DR.
4
21.2
22
C
2868 DR.
4
21.2
22
D
5068 FR, DR.
5
202
28
E
16070 ❑HD
4
18.0
19
F
37x63
25 SH
4
20.2
22
G
37x63
25 SH
5
20.2
28
H
75x63
2-25 SH
4
20.2
22
J
75x63
2-25 SH
5
20.2
28
K
37x50 5/8
24 SH
4
21.2
22
L
37x26
32/2 SH
4
21.2
22
�k 1 3/8" MIN. SOLID
WOOD DR OR 20 MIN.
FIRE —RATED DOOR
" PER R302.5.1
OR SELF —CLOSING
DOOR PER R302.1
DWELLING/GARAGE SEPARATION FROM
THE RESIDENCE AND ATTICS AND
WALLS, TO BE NOT LESS THAN 1 /2"
GYPSUM BOARD OR EQ., APPLIED TO
GARAGE FRAME SIDEWALLS AND
CEILINGS. PER R302.6
SF AREA:
LIVING 1708 SF
PORCH 96 SF
LANAI 100 SF
GARAGE 492 SF
UNDER ROOF 2396 SF
1 3'-4" 1 16I-0" 1 2'-8" 1
I HEREBY CERTIFY THAT I HAVE REVIEWED
THIS PLAN AND FOUND IT TO BE IN
COMPLIANCE WITH ASCE 7-10, & FBC 2017
(6TH. EDITION).
ENGINEER OF RECORD
David W. Smith P.E.
FLORIDA LICENSE NUMBER: 53608
Plans By:
Larry deMontmollin
90 Camhy Club Lane
Mulberry, l+1.33860
Phone: (863)397-7525
DATE: 02-12-18
DRAWN BY: LB.D.
REVISION: DATE:
RO 1
RO 2
RO 3
�sTfzl
PROJECT ADDRESS:
BUTTERFIELD INVESTMENTS, INC.
501618th. STREET
ZEPHYRHILLS, FL. 33542
CONTRACTOR:
HOUSE PLAN
FLOOR PLAN
FLOOR PLAN
DWG, BF-001-A2 REV. 0
T/ RIDGE EL
FRONT ELEVATION
.E]-,
STUCCO 0/ CNU'S
14'-8"
+20.2-22
x
00
70'-0.
SHINGLE ROOF
+21.2-22
+21.2-22
CV
STUCCO 0/ CMU'S +21.2-22
32'-0"
LEFT SIDE ELEVATION
1 /4"=1'-0"
0�1I7klr7&&iY
RIGHT SIDE ELEVATION
REAR ELEVATION
STUCCO 0/ Cfr1U'S
6'-0"
7,-4"
L(w
I HEREBY CERTIFY THAT I HAVE REVIEWED
THIS PLAN AND FOUND IT TO BE IN
COMPLIANCE WITH ASCE 7-10, & FBC 2017
(6T*L EDITION).
00
t �
w�
h . Aso
PROFESSIONAL ENGINEER SEAL
ENGINEER OF RECORD
David W. Smith P.E.
FLORIDA LICENSE NUMBER 53608
Plans By
Larry deMontmollin
90 Country Club Lane
Mulber 7v FL 33860
Phone: (863)397-7525
DATE: 02-12-18
DRAWN BY: L.B.D.
REVISION:
DATE:
RO 1
RO 2
RO 3
RO 4
PROJECT ADDRESS:
BUTTERFIELD INVESTMENTS, INC.
501618th. STREET
ZEPHYRHILLS, FL. 33542
CONTRACTOR:
HOUSE PLAN
ELEVATIONS
DWG, B F- 0 01-A3 REV. 0
69
IQ,-n"
1'-0"
lo�
--'�-- �e A • 0 /
0
1'-4"
4" N❑M, SLAB OF 3000 PSI
CONCRETE W/ 6x6 W1,4 x WL4 WWF
6 MIL, POLY VAPOR BARRIER,
LAPPED 6' & TAPED
(2) #5 REBARS C❑NT, SPACED 6" ❑,C,
ON 3" HIGH CHAIRS
CLEAN, COMPACTED,
TERMITE TREATED FILL
1 3'-4" 1 16'-0" 1 2'-8" 1
CO GRADE---_--
. ,
° A /
00 ' n • �,
N Z : a�
1'-4'0
4" N❑M, SLAB OF 3000 PSI
CONCRETE W/ 6x6 W1,4 x W1,4 WWF
6 MIL, POLY VAPOR BARRIER,
LAPPED 6" & TAPED
(2) #5 REBARS C❑NT, SPACED 6" O.C.
ON 3" HIGH CHAIRS
CLEAN, COMPACTED,
TERMITE TREATED FILL
(:D
e n
GRADE ---=--
o z
1'-4"
4" N❑M, SLAB OF 3000 PSI
CONCRETE W/ 6x6 W1,4 x W1,4 WWF
6 MIL. POLY VAPOR BARRIER,
LAPPED 6" & TAPED
(2) #5 REBARS C❑NT, SPACED 6" ❑.C.
ON 3" HIGH CHAIRS
CLEAN, COMPACTED,
TERMITE TREATED FILL
Q
I HEREBY CERTIFY THAT I HAVE REVIEWED
THIS PLAN AND FOUND IT TO BE IN
COMPLIANCE WITH ASCE 7-10, & FBC 2017
(6TEL EDITION).
ENGINEER OF RECORD
David W. Smith P.E.
FLORIDA LICENSE NUMBER: 53608
Plans By:
Larry deMontmollin
90 connay cla, Lan
14dberr9,F1.33860
Phone: (863)397-7525
DATE: 02-12-18
DRAWN BY: L.B.D.
REVISION: I DATE:
R01
RO 2
RO 3
RO 4
PROJECT ADDRESS:
BUTTERFIELD INVESTMENTS, INC.
501618th. STREET
ZEPHYRHILLS, FL. 33542
CONTRACTOR:
7'e4- Ibixor1
HOUSE PLAN
FOUNDATION PLAN
FOUNDATION PLAN
DWG, BF-001-A4 REV. 0
0
_I
1 O,-0"
SIMPSON H1, TYP. O
SIMPSON H3, TYP. 0 CORNERS (
UPLIFT PER TABLE 908.6
SPAN = 38'-0"
TRUSS SPACING = 24"
U=1664 # PER CONN.
HETA20 = U =1810# O
m4
SIMPSON HETA20, RP. O
0
0
2017 FBCR TABLE R301,2
COMPONENTS AND CLADDING - EXP, "B"
140 Ult - ROOF NET UPLIFT SCHEDULE
ROOF ZONE
DEGREES
10 SQ. FT.
> 27 TO 45 ni +19.4/-21.0 PSF
> 27 TO 451 (2) 1 +19.4/-24,0 PSF
> 27 TO 451 (3) 1 +19,4/-24,0 PSF
MAIN ROOF (N❑MINAL)
EFFECTIVE WIND AREA
20 SQ, FT.
+18,8/-20,0 PSF
+18,8/-23,0 PSF
+18,8/-23,0 PSF
50 SQ, FT.
+18,1/-18,0 PSF
+18,1/-22,0 PSF
+18,1/-22,0 PSF
NOTE:
R❑❑FING MATERIALS SHALL BE CONNECTED TO THE ROOF STRUCTURE TO RESIST
UPLIFT INDICATED IN THE NET UPLIFT SCHEDULE,
3'-0" FROM THE BUILDING EDGE GOVERNS FOR ZONE 3,
1 lJ I. I. t/ V
1'-5"
SECTION @ PORCH BEAMS
1 /2r=1'-0"
LATERAL LOADS
Design Wind Velocity:140 mph
Risk Category:ll
Wind Exposure Category: B
Internal Pressure Coeiiicents: 0.18/-0.18 (Enclosed)
Q SIMPSON META20
O SIMPSON HETA20
SIMPSON MGT
SIMPSON HUS 26
0 SIMPSON H1
SIMPSON H3
(D SEE GABLE END DETAIL
SIMPSON LSTA12
VERIFY ROOF PLAN WITH
TRUSS MANUF. DRAWINGS
AND CALCULATIONS.
FASTEN ROOF SHEATHING W/ 8d NAILS 0 6' O.C.—N
0 EDGES, 12' O.C. 0 FIELD do 4' O.C. ALONG NAILER
24 NAILER BELOW SHEATHING
FASTEN ALONG VALLEY W/ 10d NAILS 0 4- O.C.
SECTION @ VALLEY -SET ATTACHMENT
3/4'4-0°
ENG'R. TRUSS
100 SQ. FT.
+17,6/-17,0 PSF
+17,6/-21,0 PSF
+17,6/-21,0 PSF
NOTE: THE ABOVE DETAIL IS SPECIFIED AS AN ALTERNATE TO ATTACHMENT DETAILS SUPPLIED BY THE TRUSS MFGR. / ENGINEER
PRELIMINARY ROOF PLAN
FOLLOW TRUSS SUBCONTRACTOR PLANS
I HEREBY CERTIFY THAT I HAVE REVIEWED
THIS PLAN AND FOUND IT TO BE IN
COMPLIANCE WITH ASCE 7-10, & FBC 2017
(6TEL EDITION).
.p ;r� STAB Q•
•rrPLO R��.•'•a�
•••rrrrr•r
PROFESSIONAL
ENGINEER OF RECORD
David W. Smith P.E.
FLORIDA LICENSE NUMBER: 53608
Plans By:
Larry deMontmollin
9ocomayClub Tan
Mulberry, FL 33860
Phone:(863)397-7525
DATE: 02-08-19
DRAWN BY: L.B.D.
REVISION: I DATE:
RO 1
RO 2
RO 3
RO 4
PROJECT ADDRESS:
BUTTERFIELD INVESTMENTS, INC.
501018th. STREET
ZBPHYRHILIS, FI.. 33542
CONTRACTOR:
J �-�-F D i�Co✓�
HOUSE PLAN
ROOF PLAN
ROOF PLAN
1 /4r=1'-0"
DWG, BF-001-AS REV. 0
N
N
ELECTRICAL PLAN
ELECTRICAL NOTES
1. ALL WORK SHALL BE IN STRICT ACCORDANCE WITH NATIONAL ELECTRICAL CODE
ALL APPLICABLE LOCAL ORDINANCES AND IN COOPERATION WITH THE
UTILITY COMPANIES.
2. COORDINATE ALL WORK WITH ALL TRADES.
3. MOUNT ALL OUTLETS AND RECEPTACLES PLUMB AND FLUSH WITH WALLS.
4. RECEPTACLES SHALL BE MOUNTED 12" AFF UNLESS SHOWN OTHERWISE,
5. INSTALL ELECTRICAL CABLE, WIRE AND CONNECTORS AS INDICATED IN
ACCORDANCE WITH THE MANUFACURERS WRITTEN INSTRUCTION,THE
APPLICABLE REQUIREMENTS OF NEC AND THE NATIONAL ELECTRICAL
CONTRACTORS ASSOCIATION "STANDARD OF INSTALLATION° AND
IN ACCORDANCE WITH RECOGNIZED INDUSTRY PRACTICES TO ENSURE
THAT PRODUCTION SERVE THE INTENDED FUNCTIONS.
6. ALL WIRE SHALL BE STD. f10 AND 12 AND SHALL BE ROMEX OR NM
CABLE TYPE B OR APPRVED EQU L.
7. COORDINATE ELECTRICAL REQUIREMENTS FOR A/C WITH A/C CONTRACTOR.
8. ALL RECEPTACLES IN SLEEPING ROOMS SHALL BE ON AN AFCI
(ARC FAULT CURCUIT INTERRUPTER) PROTECTED CIRCUIT.
9. COMBINATION SMOKE DETECTOR/CARBON MONOXIDE DETECTOR TO BE
LOCATED WITH —IN 10' OF EACH BEDROOM
10. PROVIDE MINIMUM 75% HIGH —EFFICIENCY LIGHTING. (FBC—ENERGY CONSERVATION R404)
200 AMP MAIN BREAKER
40 CIRCUIT SURFACE MOUNT
PANEL
METER CAN BY
ELECTRIC UTILITY CO. O AMP
�- 2' C WITH 3-4/0 THW AL
TO UNDERGROUND #4 CU. GROUND
SERVICE BY ELECTRIC
UTILITY CO.
TO COL) WATER LINE
5/8" X 8" GROUND LINE
(PASCO CO. ATTACH TO FOOTER REBAR)
(BACK TO BACK SERVICE/OFFSET SIMILAR)
A EX. 200 AMP ELECTRICAL RISER
N.T.S.
100 AMP MAIN BREAKER
20 CIRCUIT SURFACE MOUNT
PANEL
#4 SER CU.
OR
100 12 SER ALUMN.
AMP
BEDROOM EMERGENCY EGRESS SHALL BE DIRECTLY TO ❑UTSIDE
EGRESS WIND❑WS SHALL BE SIZED, LOCATED AND INSTALLED PER FBC 2017
ALL BEDROOM ELECTRICAL OUTLETS MUST BE ARC -FAULT
ARC FAULT PROTECTED OUTLETS SHALL BE
INSTALLED PER NEC 210,12(B),
GFI PROTECTED CIRCUITS SHALL BE INSTALLED IN GARAGE ADDITI❑NS)
I HEREBY CERTIFY THAT I HAVE REVIEWED
THIS PLAN AND FOUND IT TO BE IN
COMPLIANCE WITH ASCE 7-10, & FBC 2017
(6TH. EDITION).
III" it
ENGINEER OF RECORD
David W. Smith P.E.
FLORIDA LICENSE NUMBER 53608
Plans By:
Larry deMontmollin
90 co,uay cmu tan
Mulbar9, FL 33860
Phoae:(863)397-75Z5
DATE: 02-08-19
DRAWN BY: L.B.D.
REVISION:
RO 1
RO 2
I�i�c?
RO 4
DATE:
PROJECT ADDRESS:
BUTTERFIELD INVESTMENTS, INC.
501618th. STREET
ZEPHYRHILLS, FL. 33542
CONTRACTOR:
HOUSE PLAN
1 /4"=1'-0"
BATHROOMS & KITCHENS, LAUNDRY ROOMS AND ❑UTSIDE RECEPTACLES
ELECTRICAL PLAN
DWG, BF-001-A6 REV. 0
PRE-ENGINEERED TRUSS ® 2'-0' O.C. (TYP.)
30 YR. DIMENSIONAL SHNGLES ON
30,f FELT PAPER ON 5 8' SHEATHING
SEE UNDERLAYMENT APPLICATION NOTE
SHEATHING THICKNESS PER R803.1
FASTEN SHEATHING PER R803.2.3.1
NAILER
CONT. ALUM.
DRIP STRIP
2x6 SIB -FASCIA
6' ALUM.
FACIA
ALUMINUM VENTED SOFFIT
SINGLE HUNG ALUM.
WINDOW (TYP.)
PLASTERING WITH PORTLAND CEMENT
PLASTER IN ACCORDANCE WITH
R702.1 MIN. THK. = 5/8'
EACH PLASTER COAT MUST BE KEPT MOIST
FOR A MINIMUM OF 48 HOURS PRIOR
TO APPLYING SUBSEQUENT COATS PER
R703.6.4
TWO -COAT CEMENT PLASTER APPLICATIONS-
7-DAY WAIT TIME BEFORE APPLYING FINISH COAT
THREE -COAT CEMENT PLASTER APPLICATIONS: r"
48 HOURS WAIT TIME BEFORE APPLYING FINISH COAT
PER R703.7.2 (1) #5 VERT. IN
FILL CELLS
42X4'INSPECTION PORT AT
EACH ALL CELL TYPICAL
MIN. OPENING = 3'
GRADE
O —
N —
MIN. BELOW GRADE
(2) 15 CONTINUOUS
DOWEL TO MATCH (1)5 VERT. IN
11CAL REINFORCING
W/25' MINIMUM LAP ALL CELLS
HEADER BLOCK
12
5
8' X 8' KNOCK -OUT BLOCK W/ 15
CONTINUOUS REBAR
SIMPSON HETA20
8' X 8' PRECAST CONC. LINTEL
ABOVE WINDOW & DOOR OPENINGS
NOTE: POURED LINTELS
BOWL BE 300o psi CoNC.
MARBLE SILL
ROOF VENTILATION AS PER
FBCR SECTION R806
CLIMATE ZONE 2A
(SEE CALCULATIONS)
ELEV. 8'-0' TOP OF MASONRY WALL
R- 30 BLOWN INSULATION
1/2' CEILING BOARD W/
KNOCKDOWN CEILING
GE PEEL OR KNOCK -DOWN
w ONE COAT
OF PAINT ON INTERIOR WALLS
8' CONC. BLOCK WALL
PER ASTM C-90 W/ TYPE M OR S a
RUNNING BOND INSTALLATION
1/2' GYP. WALL BOARD ON
3/4' P.T. FURRING STRIPS W/
3/4' TUFF-R INSULATION °D
BOARD - R-5.0
PRECAST CONIC. THIN THRU WALL SILL
® WINDOW (TYP.)
15 DOWEL TO MATCH
VERTICAL REINFORCING 4' CONC. SLAB 2500 psi w/
W/ 25' MINIMUM LAP 6x6-10/10 W.W.M.
HEADER BLOCK REINF. AND VAPOR BARRIER
6x6 10/10 W.W.M.
i ELEV. O'-O' TOP OF SLAB
12' STANDARD 90' BEND
PER TABLE R403.1.2
(FOOTING A)
TYPICAL WALL SECTION
3/4" = 1'-0'
4"X4' INSPECTION PORT AT
EACH ALL CELL TYPICAL
6x6 10/10 W.W.M. MIN. OPENING = 3'
° " vg a
6 MIL VAPOR BARRIER II—
� I =— I I=1 i l : ��a • �. III=11 I=1 11=
°i-
CLEAN, POISONED — —
_
AN S ANDAACTED BEND I I— — — I —III —I'
=1 I I=1 I I=1 I I ° n _. I I I=1 I �•
(2) #5 CONTINUOUS
PER TABLE R403.1.2
(FOOTING A)
LOAD BEARING EXTERIOR WALL FOOTING
3/4' = 1'-0"
6 MIL VAPOR BARRIER
CLEAN, TERMITE POISONED
AND COMPACTED SOIL
1/4' DIA. E.B. OR TOGGLE
BOLTS ® 24.O.C.
2X4 STUDS 016" O.C. —
2X4 P.T. STUD
HEADER BLOCK
2X4 P.T. PLATE -�
6x6 10/10 W.W.M.
6 MIL VAPOR BARRIER
(LEAN, POISONED AND COMPACTED
STANDARD 90' BEND
TABLE R403.1.2
FOUNDATION UPLIFT (ASD) DESIGN DETAILS
FOOTING
TYPE
T
(inches)
W
(inches)
SLAB/WALL
RESISTANCE
(plf)
NOTES
A
Mono
20
12
6
502
3
Mono
20
16
6
585
3
B
Mono
20
12
13
796
3
Interior
Mono
20
16
13
879
3
Interior
NOTES
1.Tributary width of 3 1 /2" slab or weight of
stemwall
and bond beam.
2.First floor
dead load multiplied by 0.6 may
also be
included.
3.All footing
dowel bars shall be same size as
wall steel,
shall have
a standard 90—degree hook, and
shall be
embedded
a minimum of 6 inches. Dowel bars shall lap
vertical wall reinforcement a minimum of 25 inches.
1 �5 VERT. IN
CELLS
UIDOWEL TO MATCH
TICAL REINFORCING
W/25' MINIMUM LAP
fXe INSPECTION PORT AT
EACH FILL CELL TYPICAL
MIN. OPENING = 3'
(2) #5 CONTINUOUS
FRAME WALL TO LOAD BEARING CMU CONNECTION
3/4" = 1'-0"
4' THICK CONIC. SLAB _ 4»
WITH 6x6-10/10 W.W.M.
ON 6 MIL VAPOR
BARRIER
° �v.4 q
� 00 � -III=III � • .: • : •
' I I=III III=III
8x8x16 CMU EXT.
151 FELT
1 4' DIA. EB.
BOLTS ® 24'
2x4 P.T. STUD
2X STUDS 0 16" O.C.
W/ R-11 INSUL (MIN. w/"2X P.T.
BOTTOM PLATE W/ 1 2'0 L"
BOLTS AT 4'-0' O.C.
(MIN. 6' EMBEDMENT)
4' THICK CONC. SLAB
NTH 6x6-10/10 W.W.M.
ON 6 MIL VAPOR
BARRIER
�— (2) #5 CONTINUOUS
8" 1'-4" 4'
SECTION @ STEPDOWN @ GARAGE
3/4" = 1'-0"
STUD BEARING WALL TO BLOCK SECTION
3/4' = 1'-0"
#5 VERT. WALL REINF.
d GROUT CELLS SOLID
1 /2%8' J-BOLT
W/ NUT & 2' SQ. WASHER
x 1/8' OR 9/16" WASHER
(3) PER SIDE
P.T. DOOR STOP
TRACK BRACKET - 2x6 PT JAMB
ATTACH PER MFG.
RECOMMENDATIONS
GARAGE DOOR ATTACHMENT DETAIL
3/4" = 1'-0"
LATION
GE ARE SEPARATION
3ARD, GARAGE SIDE
26
2x4 STUDS Q 16' O.C.
l�
'1
12' J-BOLTS
I HEREBY CERTIFY THAT I HAVE REVIEWED
THIS PLAN AND FOUND IT TO BE IN
COMPLIANCE WITH ASCE 7-10, & FBC 2017
(6T& EDITION.
S
•.�` �o •v�CENS •�
W ".
•� STATEM�!.•
�O�'•. O
i R
ONAIL�`����
Ilffill
PROFESSIONAL ENGINEER SEAL
ENGINEER OF RECORD
David W. Smith P.E.
FLORIDA LICENSE NUMBER 53608
Plans By:
Larry deMontmollin
90 Country Club Lane
Mu% ny, FL 33860
Phone: (863)397-7525
DATE: 02-08-19
DRAWN BY: L.E.D.
REVISION:
DATE:
R01
RO 2
RO 3
RO 4
PROJECT ADDRESS:
BUTTERFIELD INVESTMENTS, INC.
501618th. STREET
ZEPHYRHILLS, FL. 33542
CONTRACTOR:
HOUSE PLAN
WALL SECTION & DETAILS
DWG. BF-001-A7 REV.0
0
O 4 ft.
5 ft.
O O O
4 ft. O
4 ft. O 4 ft.
4 ft. D O O
O 2 4 ft.
Oft.
5 ft. O � � O 4 ft.
O 4 ft. 4 ft. O
O 4 ft. 5 ft. O O 5 ft. 4 ft. 2
ROOF NAILING
1 /4"=1'-0"
2017 FBCR TABLE R301.2
COMPONENTS AND CLADDING - EXP. "B"
140 Ult - ROOF NET UPLIFT SCHEDULE
ROOF
DEGREES
ZONE
MAIN ROOF (N❑MINAL)
EFFECTIVE WIND AREA
10 SQ, FT,
20 SQ. FT.
50 SQ. FT.
100 SQ. FT.
> 27 TO 45
O
+19.4/-21,0
PSF
+18.8/-20.0 PSF
+18,1/-18,0 PSF
+17.6/-17,0 PSF
> 27 TO 45
O
+19,4/-24,0
PSF
+18.8/-23,0 PSF
+18,1/-22.0 PSF
+17.6/-21,0 PSF
> 27 TO 45
O
+19,4/-24,0
PSF
+18,8/-23,0 PSF
+18,1/-22.0 PSF
+17.6/-21.0 PSF
NOTE:
R❑❑FING MATERIALS SHALL BE CONNECTED TO THE ROOF STRUCTURE TO RESIST
UPLIFT INDICATED IN THE NET UPLIFT SCHEDULE,
3'-0' FROM THE BUILDING EDGE GOVERNS FOR ZONE 3,
R803.2.3.1 SHEATHING FASTENING
WOOD STRUCTURAL PANEL SHEATHING SHALL BE FASTENED
TO ROOF FRAMING WITH 8d RING -SHANK NAILS AT 6" O.C.
AT EDGES AND 6" O.C. AT INTERMEDIATE FRAMING.
RING -SHANK NAILS SHALL HAVE THE FOLLOWING MINIMUM
DIMENSIONS:
1. 0.113 INCH SHANK DIAMETER.
2. RING DIAMETER OF 0.012 OVER SHANK DIAMETER.
3. 16 TO 20 RINGS PER INCH.
4. 0.280 INCH FULL ROUND HEAD DIAMETER.
5. 2 INCH NAIL LENGTH.
R905.2.2 UNDERLAYMENT APPLICATION
UNDERLAYMENT SHALL BE INSTALLED USING ONE OF THE FOLLOWING
METHODS:
2. FOR ROOF SLOPES OF FOUR UNITS VERTICAL IN 12 UNITS
HORIZONTAL (33% SLOPE) OR GREATER, UNDERLAYMENT SHALL
COMPLY WITH ASTM D 226, TYPE II OR TYPE IV OR ASTM D 6557 AND
SHALL BE ONE LAYER APPLIED IN THE FOLLOWING MANNER.
UNDERLAYMENT SHALL BE APPLIED SHINGLE FASHION, PARALLEL TO
AND STARTING FROM THE EAVE AND LAPPED 2", FASTENED WITH
1-INCH ROUND PLATIC CAP, METAL CAP NAILS OR NAILS AND
TIN -TABS ATTACHED TO A NAILABLE DECK WITH TWO STAGGERED
ROWS IN THE FIELD OF THE SHEET WITH A MAXIMUM FASTENER
SPACING OF 12 INCHES O.C., AND ONE ROW AT THE OVERLAPS
FASTENED 6 INCHES O.C. SYNTHETIC UNDERLAYMENT SHALL BE
FASTENED IN ACCORDANCE WITH THIS SECTION AND THE
MANUFACTURER'S RECOMMENDATIONS. END LAPS SHALL BE OFFSET BY
6 FEET.
3. AS AN ALTERNATIVE, THE ENTIRE ROOF DECK SHALL BE COVERED
WITH AN APPROVED SELF -ADHERING POLYMER MODIFIED BITUMEN
SHEET MEETING ASTM D 1970 OR AN APPROVED SELF -ADHERING
SYNTHETIC UNDERLAYMENT INSTALLED IN ACCORDANCE WITH THE
MANUFACTURER'S INSTALLATION INSTRUCTIONS.
R905.2A ASPHALT SHINGLES
ASPHALT SHINGLES SHALL COMPLY WITH ASTM D225 OR
D3464.
ASPHALT SHINGLES SHALL BE RATED FOR INDICATED WIND
SPEED.
R905.2.4 ASPHALT SH [NGLE FASTENERS
FASTENERS FOR ASPHALT SHINGLES SHALL BE GALVANIZED,
STAINLESS STEEL, ALUMINUM, OR COPPER ROOFING NAILS,
MINIMUM 12 gage SHANK WITH A MINIMUM 8 INCH DIAMETER
HEAD, ASTM F 1667, OF A LENGHT TO PENETRATE
THROUGH THE ROOFING MATERIALS AND A MINIMUM OF 4
INCH INTO THE ROOF SHEATHING. WHERE THE ROOF
SHEATHING IS LESS THAN 4"INCHES THICK THE FASTENERS
SLAA PENETRATE THROGH THE SHEATHING. FASTENERS
SHALL COMPLY WITH ASTM F 1667.
R905.2.6 ASPHALT SH [NGLE ATTACHMENT
ASPHALT SHINGLES SHALL HAVE THE MINIMUM NUMBER OF FASTENERS
REQUIRED BY THE MANUFACTURER, BUT NOT LESS THAN FOUR
FASTENERS PER STRIP SHINGLE OR TWO PER INDIVIDUAL SHINGLE.
I HEREBY CERTIFY THAT I HAVE REVIEWED
THIS PLAN AND FOUND 1T TO BE IN
COMPLIANCE WITH A= 7-10, & FBC 2017
(6TH. EDITION).
BYATE OF �`
••�
IONA%-�
MillO
PROFESSIONAL ENGINEER SEAL
ENGINEER OF RECORD
David W. Smith P.E.
FLORIDA LICENSE NUMBER 53608
Plans By
Larry deMontnolfin
90 Country Club Lase
Mulberry, FL 33860
Phone: (863)397-7525
DATE: 02-08-19
DRAWN BY: L.E.D.
REVISION:
DATE:
RO 1
RO 2
RO 3
RO 4
PROJECT ADDRESS:
BUTTERFIELD INVESTMENTS, INC.
501618th. STREET
ZEPHYRHILLS, FL. 33542
CONTRACTOR:
HOUSE PLAN
ROOF NAILING
DWG, BF-001-A8 REV.0
4" PLYWD.
16d ® 8" O.C.
L BRACE GABLE END
TRUSS
'_X4 DIAG.
3RACE
FOLLOW
RUSS MANUF.
ZECOMMENDATIONS)
4) 10d NAILS
G^-r^u ILr1 � L IN1`1L J illACING
C❑NTINU❑US @ 48' O.C.
GABLE END BRACING DETAIL
T' BRACE ATTACHED W/
10d NAILS 0 4" OC, TYP.
2X,I r'orncc_Qonr'iKir
TOP/BOTTOM CHORD
REQ. MINIMUM TRUSS BRACING
CMU END WALL W FLAT CEILING
WIND SPEED 140 MPH 3-SECOND GUST & MEAN ROOF HEIGHT UP TO 30'-0"
2x4 BLOCKING 0
48" O/C
"L" BRACE ATTACHED W/
10d NAILS 0 4" OC, TYP.
WEB-1 w1" TRUSS WEB
20 BLOCKING 0
48" O/C
,JLE TRUSS WEB
SEE TRUSS MFR. CUT
SHEETS FOR
ADDITIONAL BRACING
THAT MAY BE REQ'D.
7/16" NOI
APPROVAL
GABLE END TRU
BRACING DETAIL
(1) SIMPSON LSTA12
STRAP 0 48" O.C.
')..A I11A(`nkw DDArwr`
-ENGINEERED TRUSSES
4" O.C.
MASONRY GABLE END BRACING DETAIL
I HEREBY CEIMFY THAT I HAVE REVIEWED
THIS PLAN AND FOUND IT TO BE IN
COMPLIANCE WITH ASCE 7-10, & FBC 2017
(6TH. EDITION).
J�f E
0
co•
pee 1*
�91
ii1 %r�►`�r�►`�
a,
ENGINEER OF RECORD
David W. Smith P.E.
nORIDA LICENSE NUMBER S3608
Plans By:
Larry deMontmollin
90 conaay Club Tan
Mulberry, FL 33860
Phonx(863)397-7525
DATE: 02-08-19
DRAWN BY: L.B.D.
REVISION: I DATE:
R01
RO 2
RO 3
RO 4
PROJECT ADDRESS:
BU'1TERFIBLD INVSSfMBNTS, INC.
501618th. S17tBBT
ZBPHYRHILIS, F4 33542
CONTRACTOR:
-Teim
HOUSE PLAN
sEcnoN A
1
GABLE TRUSS DETAILS
DWG, BF-001-A9 REV. 0