Loading...
HomeMy WebLinkAbout5931 Gall Blvd�I 1 0 QTY. SYMBOL DESCRIPTION CABLE TYPE SUPPLIED INSTALLED NOTES BY: BY: VER. AT AHU TERMINAL STRIP 8C T-STAT CABLE EMS SUPPLIER GENERAL QTY. ONE (1) PER CONTRACTOR HVAC UNIT. 1 OT OUTDOOR AIR TEMP BELDEN 8761 OR EMS SUPPLIER GENERAL QTY. ONE (1) PER MTD. @ 8'-0" A.F.F. EQUIVALENT (22AWG, CONTRACTOR RECEIVING ENTRY. 2C, STRANDED, SHIELDED) VER. ST SUPPLY TEMP BELDEN 8761 OR EMS SUPPLIER GENERAL QTY. ONE (1) PER (501-1121) MTD. IN EQUIVALENT (22AWG, CONTRACTOR HVAC UNIT. SUPPLY DUCT 2C, STRANDED, SHIELDED) VER. TEMPERATURE BELDEN 8761 OR EMS SUPPLIER GENERAL QTY. ONE (1) PER TS SPACE SENSOR EQUIVALENT (22AWG, CONTRACTOR HVAC UNIT ZONE. (809-6590) MTD. @ 2C, STRANDED, 8'-0" A.F.F. SHIELDED) 1 O RJ-11/RJ-45 DATA 24 GA., GENERAL GENERAL QTY. ONE (1) AT JACK, PHONE 4 TWISTED -PAIR, CONTRACTOR CONTRACTOR OFFICE COMBO. CATEGORY -FIVE (CAT 5) DATA CABLE 2 MOTION SENSOR LEVITON EZ-FIND GENERAL GENERAL QTY. ONE (1) PER M SWITCH. ODS-10-IDW CONTRACTOR CONTRACTOR MEN'S R.R. QTY. ONE (1) PER WOMEN'S R.R. SENSOR PLAN KEYED NOTES ALWAYS INSTALL THESE SENSORS AT 8'-0" A.F.F. THE EXACT MOUNTING LOCATION OF THE HVAC SENSORS "TS" MAY VARY DEPENDING ON THE STORE LAYOUT &DUCT CONFIGURATION. REFER TO SITE SPECIFIC MECHANICAL DRAWINGS FOR HVAC ZONED SENSOR MOUNTING LOCATIONS. IF SENSORS ARE MOUNTED ON EXTERIOR WALLS DUE TO DUCT CONFIGURATION, THEY ARE THEN TO BE INSULATED TO PREVENT AIR INFILTRATION. IF ADDITIONAL HVAC UNITS ARE USED, ADD ADDITIONAL TEMPERATURE SENSORS "TS". PROVIDE LABEL ON FACE OF EACH UNIT. LINE #1 -TWO RJ-11 PORTS. ONE (1) LOCATED IN aPHONE OFFICE W/RJ-45 DATA JACK COMBO AND ONE (1) AT REGISTER. 24 GA. CAT 5, 4-PAIR TWISTED WIRE ONLY. USE BLUE AND BLUE & WHITE WIRES. HOOK TO LINE #1 TERMINAL IN RJ-11 JACK EACH PHONE JACK TO HAVE DEDICATED, SEPARATE HOME RUN TO DMARC. LABEL AS "PHONE" AT THE DESTINATION AND AT DMARC. PHONE COMPANY PROVIDES FINAL HOOK UP TO DMARC ONLY. PHONE LINE #2 - RJ-11 PHONE JACK SUPPLIED AND WIRED BY CONTRACTOR. REFRIGERATION PANEL CX E2 400. PANEL BY OTHERS. [3]EMS CONNECTION FROM THIS PANEL TO HVAC AND LIGHTING PANEL BY OTHERS. ELECTRICAL CONTRACTOR TO RUN AN EMPTY 1-1/2" CONDUIT WITH PULL ROPE BETWEEN THE TWO PANELS. ADDITIONAL HVAC UNIT WHEN REQUIRED. aADD REQUIRED NATIONAL ACCOUNT VENDORS CONTACT INFORMATION SUBJECT TO CHANGE COMPANY - PHONE # CONTACTS REQUIRED ITEMS EMERSON CLIMATE TECHNOLOGIES - WEBSITE EMS SUPPLIER NOTE: CUSTOMIZED DOLLAR GENERAL EMS ALL QUESTIONS PERTAINING TO THE EMS PANEL, http://dollargeneralbid.ectsolutions.net PANEL REQUIRES STORE #, CITY, STATE, ZIP CODE & SYSTEM INSTALLATION & SETUP SHOULD BE USER NAME: dollargeneralbid QTY.OF HVAC UNITS FOR THE INSTALL SITE WHEN DIRECTED TO EMERSON'S DOLLAR GENERAL PASSWORD: dollargeneralbid ORDERING. EMS SYSTEMS INSTALLATION GUIDE WITH SUPPORT TEAM AT 770-425-2724. 1 1 PHOTOS IS AVAILABLE ON NATIONAL ACCOUNT WEBSITE. ADJACENT TENANT � ■ w ■ r N r . . ■ / _ 1w _ ■ w NOT TO SCALE STRUCTURE ABOVE AND RUN AS HIGH AS POSSIBLE ALONG PERIMETER WALLS TO RECEIVING AREA. PROPOS ED LOCATION: ZEPHYRHILLS FL 5931 GALL BLVID. REVISED BY:0 Sim ---- • W N 0 W Z c'`) '` W C) E co z wC) o a o pu)>cn j U") 0o�o Lo CD Q1 CD o0 O O DATE: 5/3,0/2018 'SCALE: NTS SHEET NO: EMS1 .11 MODEL 611005701 78"x78" NON -PENETRATING SATELLITE SLED MOUNT WITH NON -SLIP RUBBER PAD SUPPLIED BY VSAT INSTALLER. z O F— J Q z Orr zw ¢_j J m Uz QQ d> Om GENERAL CONTRACTOR TO PROVIDE ROOF PENETRATION AS NEEDED. 0 z �W 0" 1-1/4" CONDUIT & PULL 0 Q STRING BY GENERAL CONTRACTOR Q COAXIAL CABLE BY VSAT INSTALLER RECEIVINGTHE FINAL DMARC BY TO E INTO LABEL ENDS WITH LOCAL PHONE COMPANY YELLOW PHASING TAPE AREAAIIlllill DMARC MOUNT ON WALL WITHIN ONE �- FOOT OF DMARC (BY G.C. ® LABEL END WITH % ® PRIOR TO TURNOVER) YELLOW PHASING TAPE DSL (2) RJ-45 DATA JACK IIIIIIII IIIIIIII IIII IIII = (2) RJ-11 PHONE JACK ® — COMBO IN OFFICE SUPPLIED WITH s ®,5/1 TERMINAL CONNECTION ���IlIIIIIIl11111lIIIIIl111IIIlfllIII1!l1111II1311111111IIIIIIUlI11111114 RJ-11 PHONE JACK LABEL END WITH Z YELLOW PHASING TAPE F ji a Alk Mlk ANIL 2" CONDUIT AND PULL STRING BY LABEL END WITH GENERAL CONTRACTOR BROWN PHASING TAPE #1 CONDUIT TO ABOVE OFFICE CEILING 1111 II HIIIIIIIIIIIIII1111111111111111HIM 1111111111111111111111111111111111111111HIM IIIIIIIIIIIIIIIIIIIIIIII31II11111111111111111111 B� #2 CONDUIT TO r ABOVE OFFICE CEILING 1" CONDUIT & PULL STRING BY GENERAL CONTRACTOR LABEL END WITH YELLOW PHASING TAPE Eck VSAT 1111IIIIII(D Box SUPPLIED AND INSTALLED BY VSAT INSTALLER IN OFFICE REQUIRED ACCOUNT VENDORS COMPANY CONTACTS PHONE # LOW VOLTAGE & VOICE/DATA CROSSCOM NATIONAL ANDREA LEMAY 847-850-6297 dollargeneral@crosscomnational.com CO, CT, DE, FL, IA, IL, IN, KS, MA, MD, ME, MI, MN, MO, ND, NE, NH, NJ, NY, OH, PA, RI, SD, VT, WI, WV ASD 828-624-1046 CHRIS RUDNITSKI crudnitski@asd-usa.com AL, AR, AZ, CA, GA, KY, LA, MS, NC, NM, NV, OK, OR, SC, TN, TX, VA NOTE: c� z J FW 0 Z J Q uj U cn > 0 m Q �0113 Q41 11111"iff-d-, ed lo�lan"l��������l��������������������I �w X REGISTER AREA LAYOUT VARIES MOUNT J-BOX AT 12' 1" CONDUIT AND PULL STRING BY GENERAL CONTRACTOR PROVIDE 20 FEET OF SERVICE CABLE COILED AT CENTER OF SALES FLOOR WITH SURFACE MOUNT RJ45 JACK r f, �� aR?i{6�s�ll k��iG t J i a 24 PORT DATA PATCH PANEL MOUNTED ON BRACKET ABOVE THE DATA HUB IN OFFICE. a(31 dk im D - LINK DSS - 16 PORT DATA HUB LOCATED IN THE OFFICE, SUPPLIED AND INSTALLED BY THE DOLLAR GENERAL STORE OPENING TEAM. *ALL CABLES ARE REQUIRED TO BE TESTED FOR CONTINUITY AT TIME OF INSTALLATION. LABEL ENDS WITH RED PHASING TAPE CONDUIT RESPONSIBILITY o z I LUIVUUI I& I-'ULL J 1 KIINU C) BY GENERAL CONTRACTOR °zw Uco w 0 m a BUNDLE ALL CABLES TOGETHER AND PENETRATE THE OFFICE CEILING GRID AT ONE LOCATION DIRECTLY ABOVE THE DATA PATCH PANELS. FIELD VERIFY EXACT LOCATION. CONDUIT START END SIZE CONDUIT RESPONSIBILITY *CABLING RESPONSIBILITY NUMBER 1 RECEIVING AREA OFFICE (HUB) 2" GENERAL CONTRACTOR LOW VOLTAGE VENDOR 2 OFFICE OFFICE (HUB) 1" GENERAL CONTRACTOR LOW VOLTAGE VENDOR VOICE / DATA PORT 3 SALES FLOOR OFFICE (HUB) 1" GENERAL CONTRACTOR LOW VOLTAGE VENDOR REGISTER CONNECTION SALES FLOOR 4 QUADRANT OFFICE (HUB) 1" GENERAL CONTRACTOR LOW VOLTAGE VENDOR CONNECTION 5 SATELLITE OFFICE (HUB) 1-1/4" GENERAL CONTRACTOR LOW VOLTAGE VENDOR *UNLESS OTHERWISE NOTED, ALL RESPONSIBILITIES SHOULD FOLLOW THIS CHART. ALL LOW VOLTAGE WIRING INSTALLED IN CABLE TRAY FOR OPEN CEILING LAYOUTS. 2" CONDUIT FROM RECEIVING TO DATA VOICE PORT 1-1/4" CONDUIT FROM SATELLITE TO OFFICE HUB - VOICE / DATA POR 1" CONDUIT FROM VOICE DATA PORT TO OFFICE HUB AT EQUIPMENT MAP - OFFICE HUB AT EQUIPMENT MAP ALL CABLES AT THE OFFICE WILL NEED TO BE WRAPPED IN PHASING TAPE CONSISTENT WITH THE FOLLOWING COLORS: RED TAPE CASH REGISTER DATA BLUE TAPE ELEC. EMS DATA BROWN TAPE OFFICE DATA ELECTRICAL, DMARC AND EMS PANELS IN RECEIVING AREA. 1" CONDUIT FROM SALES FLOOR QUADRANTS TO OFFICE HUB 1" CONDUIT FROM SALES REGISTER CONNECTION TO OFFICE HUB TYPICAL FLOOR PLAN NOT TO SCALE ORANGE TAPE COOLER/FREEZER EMS DATA YELLOW TAPE PHONE CABLE TO DMARC Wire Symbols RJ-45: 24 GA., 4 TWISTED PAIR, CATEGORY -FIVE (CAT 5) DATA CABLE WITH MODULAR RJ-45 END. RJ-11: 24 GA., 4 TWISTED PAIR, CATEGORY -FIVE (CAT 5) DATA CABLE WITH MODULAR RJ-11 END. USE ONLY THE BLUE & WHITE AND SOLID BLUE WIRES. ALL OTHER WIRES TO BE FOLDED BACK AND TAPED TO THE CABLE. COAXIAL CABLE WITH RF CONNECTOR GENERAL CONTRACTOR NOTE: EXPANSIONS AND RELOCATIONS REQUIRE THE GENERAL CONTRACTOR TO PROVIDE THE MATERIALS AND LABOR INDICATED ON THIS DIAGRAM AS BY "LOW VOLTAGE INSTALLER" IN ADDITION TO CONDUITS INDICATED. DOLLAR GENERAL DOES NOT PROVIDE AND/OR INSTALL THE LOW VOLTAGE AND DATA CABLING ON THOSE PROJECTS. DATA CABLING SCHEMATIC NOT TO SCALE PROPOSE D LOCATION: ZEPHYRHILLS FL 5931 GALL BLVID. REVISED BY: Sim ---- 0 W0 W 4-a M W ���� co 0 o �0Z J L0 LO LO C,6 2 T_ CD Q O 0 0 0 DATE: 5/30/2018 SCALE: N.T.S. SHEET NO: E3 BUILDING SIGNS SIGN SIZE SIGN WT. # OF CKTS. AMPS VOLTS 3'x23' BOX 380 LBS. (1) 15 A 2.5 115 3'-9"x26' BOX 441 LBS. (1) 15 A 5 115 4'-6"x33'-3" BOX 750 LBS. (1) 15 A 8.4 115 5'x40' BOX 1220 LBS. (1) 15 A 10 115 BUILDING LETTERS SIGN SIZE SIGN WT. # OF CKTS. AMPS VOLTS 18" 215 LBS. (2) 15 A 19.6 115 24" 288 LBS. (1) 15 A & (1) 20 A 23.45 115 30" 387 LBS. (2) 20 A 28 115 36" 649 LBS. (2) 15 A & (1) 20 A 32.9 115 REQUIRED NATIONAL ACCOUNT VENDORS COMPANY NATIONAL CONTACT PHONE # / EMAIL BUILDING SIGNS, BUILDING LETTERS, PYLON SIGNS DUALITE SALES ROSE SHINKLE 513-724-7100 (AR, IA, IL, IN, KY, KS, LA, MI, MN, MO, MS, OH, & SERVICE (SR. PROJECT MANAGER) rshinkle@dualite.com OK, TN,TX,WI) SIGN RESOURCE IDENTITY GROUP ANGII HEIDBRINK 323-485-4720 (AZ, CA, CO, NE, NM,NV, SD, UT, WY) EVERBRITE CHRISTINE OLSON 414-427-2329 (AL, CT, DE, FL, GA, MA, MD, ME, NC, NH, NJ, NY, PA, RI, SC, VA, VT, WV) NATIONAL ACCOUNT & CONTACT INFORMATION SUBJECT TO CHANGE LINE #1 WILL HAVE TWO RJ-11 JACKS. ONE AT REGISTER, SECOND IN THE OFFICE. LABEL AS PHONE. ALL PHONE JACKS REQUIRE A BLUE SEPARATE 24 ga. CAT 5,4 PAIR HOME RUN TO & DMARC. NOTE SEPARATE GROUND WIRES. REFER BLUE/WHITE TO SHEET E-3 FOR DETAILS. BUZZER - TORK MODEL #TA725 W/TRANSFORMER MODEL #TA592. COMMERCIAL GRADE PUSH BUTTON (p 125V NEMA 5-20R DUPLEX (p 125/250V NEMA L14-20-R 4 PRONG TWIST LOCK 125V NEMA 5-20R QUAD '-❑ DISCONNECT I POWER POLE -BLACK MAGIC v PHONE JACK @REGISTER O VOICE/DATA PORT = RJ-111 RJ-45 DATA JACK, PHONE COMBO @OFFICE $nn PROVIDE OCCUPANCY LIGHT SENSOR - LEVITON ODS 10-IDW 20 AMP TOGGLE SWITCH NL NIGHT LIGHT CIRCUIT ELECTRICAL SPECIFICATIONS: ALL EXPOSED WIRING SHALL BE CONTAINED IN CONDUIT OF PROPER SIZE. 2. ALL WIRING SHALL CONFORM TO LOCAL, STATE, AND FEDERAL CODES. 3. ELECTRICAL SERVICE TO BE MINIMUM 400 AMP, 3-PHASE (PREFERRED) OR 600 AMP, SINGLE PHASE OR LARGER IF REQUIRED BY CODE OR ELECTRICAL LOAD. 4. REGISTER POWER POLES - VERIFY REGISTER CONFIGURATION ON FINAL FIXTURE PLAN BEFORE ORDERING AND INSTALLATION OF ELECTRICAL COMPONENTS. CUSTOM BUILT POWER POLE ASSEMBLY AVAILABLE FROM D&P CUSTOM LIGHTS & PRODUCTS INC. PHONE # (800) 251-2200 OR (615) 350-7800, 7111 COCKRILL BEND INDUSTRIAL ROAD. NASHVILLE, TN 37209 EXTERIOR EXPOSED PHONE LINES TO BE INSTALLED IN RIGID CONDUIT. PROVIDE EMERSON 3/4" x 5-FT. METALLIC CABLE U-GUARD #755 OR EQUAL. 6. ELECTRIC PANELS TO BE LABELED CORRECTLY WITH LEGIBLE PRINT. 7. LOW VOLTAGE VENDOR TO PROVIDE AND INSTALL ONE (1) 24 GA., 4 TWISTED -PAIR, CATEGORY -FIVE (CAT5) DATA CABLE WITH MODULAR COMBO RJ-11/RJ/45 JACK AT MANAGER'S OFFICE. CABLE TO BE RUN FROM JACK TO DATA HUB LOCATION WITH 6'-0" LEFT COILED FOR INSTALLATION TO DATA HUB. A RJ-45 MALE FITTING SHOULD BE CRIMPED ON THIS END. DOLLAR GENERAL STORE OPENING TEAM WILL MAKE FINAL CONNECTION INTO THE DATA HUB. 8. SEE SHEET F1 FOR COOLER/FREEZER OPTIONS. VERIFY FINAL LOCATION AND NW OF COOLERS AND FREEZERS ON FINAL FIXTURE PLAN BEFORE ORDERING AND INSTALLATION OF ELECTRICAL COMPONENTS. EACH COOLER REQUIRES A 20 AMP DEDICATED GROUND CIRCUIT TO BE USED FOR A 110v OUTLET. EACH OF THESE U DRAW 12 AMPS. EACH FREEZER REQUIRES ONE - 125/250V OUTLET NEMA #L14-20 PRONG TWIST LOCK. EACH UNIT DRAWS 16 AMPS. TWO DOOR FREEZER IN RECEI AREA REQUIRES ONE 125/250V NEMA 14-20R OUTLET ON A 20 AMP DEDICATED CIR UNIT DRAWS 8 AMPS. PYLON SIGNS SIGN SIZE SIGN WT. # OF CKTS. AMPS VOLTS 4'x8' 188 LBS. (1) 15 A 1.7 115 5'x10' 375 LBS. (1) 15 A 3.4 115 6'x16' 738 LBS. (1) 15 A 5 115 NOTES: 1. PROVIDE AND INSTALL CONDUIT, JUNCTION BOXES, D&P CONNECTORS AND/OR POWER POLE(S) FOR CASH REGISTER(S) PER TENANT'S CRITERIA PLANS, VERIFY LOCATION OF JUNCTION BOXES WITH TENANT'S FIXTURE FLOOR PLAN PROVIDED BEFORE TURNOVER DATE. 2. PROVIDE AND INSTALL POWER POLE(S) FOR REGISTERS AND ICE CREAM FREEZER PER TENANT'S CRITERIA PLANS. 3. PROVIDE AND INSTALL POWER POLES FOR REFRIGERATION UNITS PER TENANT'S CRITERIA PLANS. 4. VERIFY LOCATION OF POWER POLES WITH TENANT'S FIXTURE FLOOR PLAN PROVIDED BEFORE TURNOVER DATE. 5. PROVIDE AND INSTALL ELECTRICAL RECEPTACLES PER TENANT'S CRITERIA PLANS. 6. PROVIDE AND INSTALL BREAKER LOCKS ON THE FOLLOWING: REGISTER POWER POLES, SALES FLOOR COOLERS AND FREEZERS, RECEIVING/SALES NIGHT LIGHTS, SECURITY OUTLETS, OUTDOOR ICE MERCHANDISER, AUTOMATIC DOORS, TELEPHONE BOARD, DOOR BUZZER, OFFICE RECEPTACLES, OFFICE LIGHTS, BREAK ROOM, RESTROOMS, EMERGENCY/EXIT LIGHTS AND AS SHOWN ON PANEL LAYOUT. 7. FULLY LABEL ALL PANEL SCHEDULES ACCURATELY AND LEGIBLY. HAND WRITTEN LABELS NOT ACCEPTABLE &PROVIDE AND INSTALL CONDUIT FROM PANEL TO NEW BUILDING SIGN LOCATION, TERMINATING IN A JUNCTION BOX TO BE CENTERED HORIZONTALLY ON TENANT'S PROPOSED SPACE AND VERTICALLY ON THE CANOPY. NOT TO SCALE 9. PROVIDE AND INSTALL A TIMER AND PHOTOCELL COMBINATION PER TENANT'S CRITERIA PLANS. ROUTE THE FOLLOWING CIRCUITS THROUGH THE TIMER/PHOTECELL ASSEMBLY: PYLON SIGN, BUILDING SIGN, PARKING LOT LIGHTS, WALL PACKS, AND CANOPY LIGHTS 10. PROVIDE AND INSTALL 1" CONDUIT WITH PULL STRING ABOVE THE MANAGER'S OFFICE WITH ROOF OR WALL PENETRATION FOR VSAT (TENANT SATELLITE). COORDINATE EXACT LOCATION WITH TENANT CONSTRUCTION DEPARTMENT PROJECT MANAGER. 11. PROVIDE AND INSTALL CONDUIT WITH PULL STRINGS AT MANAGER'S OFFICE, CASH REGISTER AREA AND DMARC PANEL. COORDINATE EXACT LOCATION WITH TENANT CONSTRUCTION DEPARTMENT PROJECT MANAGER. 12. PROVIDE 1" CONDUIT FROM OFFICE TO CENTER OF SALES AREA TERMINATING WITH A JUNCTION BOX. HOLD CONDUIT TIGHT TO STRUCTURE. WAP MOUNTED AT 12'-0" AFF, 13. PROVIDE AND INSTALL CONDUIT FROM PANEL, THROUGH BUILDING, AND UNDERGROUND TO PYLON SIGN LOCATION. STUB UP CONDUIT 12" ABOVE GRADE AT PYLON LOCATION, CAP AND MARK WITH 36" HIGH STAKE. 14. LOW VOLTAGE VENDOR TO PROVIDE AND INSTALL 24 GA., 4 TWISTED -PAIR, CATEGORY -FIVE (CAT5) DATA CABLE WITH MODULAR COMBO RJ-11/ RJ-45 JACK AT MANAGER'S OFFICE. CABLE TO BE RUN FROM JACK TO DATA HUB LOCATION WITH 6' LEFT COILED ABOVE CEILING FOR INSTALLATION TO DATA HUB. AN RJ-45 MALE FITTING SHOULD BE CRIMPED ON THIS END. DOLLAR GENERAL STORE OPENING TEAM WILL MAKE FINAL CONNECTION INTO THE DATA H U B . *NOTE: PROVIDE 208V, 1 PHASE CONNECTION T A J-BOX AT 90" AFF WITH 3 #12 CU. & #12 GROUND IN 4"C. R.C. TO PROVIDE AND INSTALL 30A/2NF DISCONNECT SWITCH AND WIRE FROM DISCONNECT SWITCH TO EQUIPMENT CONNECTIONS. VERIFY FINAL LOCATION OF ALL ELECTRICAL FIXTURE LAYOUT PLAN PROVIDED BY STORE NT REQUIRES L SPACE. @ 7'-0" A.F.F. WITH THE FINAL PLANNING. 1 2 PROPO SE D LOCATIO N: ZEPHYRHILLS FL 5931 GALL BLVD. REVISED BY: Sim ---- • W N 0 z W M '` W �o� o E Q W z0 0 o Iql- J > �ij U) 0c) Q O � 0 DATE: 5/30/2018 SCALE: N.T.S. SHEET NO: El