Loading...
HomeMy WebLinkAbout6440 Fort KingUsl• .A HOUNDS TOWN - ZEPHYR HILLS THE PROJECT CONSISTS OF AN INTERIOR TENANT REMODEL TO CONSTRUCT A DOG DAYCARE FACILITY. BACK OF HOUSE IS EMPLOYEE ONLY AND WILL HAVE NO PUBLIC ACCESS. THE RECEPTION IS RESTRICTED PUBLIC ACCESS FOR PEOPLE TO DROP OFF AND PICK UPTHEIR DOGS IN Sim THE MORNING AND EVENINGS. THERE WILL BE A MAX 1 NUMBER OF FIVE EMPLOYEES DURING OPERATION. THE �Alo,, RECEPTION AREA CONSTITUTES LESS THAN 25% OF THE TOTAL AREA OF THE SPACE. � Ref M Z 1 View N Z ie PROPSED USE: DOG DAY CARElD OWNER'S AUTHORIZED AGENT: JANSEN GEHRING 1 A101 1 OWNED BY A PRIVATE OWNER 1 Ref LEAD DESIGN PROFESSIONAL: CORTLAND MORGAN View Name CODE: 2020 FBC GROSS PROJECT AREA: 4305.45 SF USE GROUP - B OCCUPANT LOAD: NFPA 150 ANIMAL HOUSING FACILITIES CLASSIFICATION: CLASS 1 FACILITY; CATEGORY B ANIMALS RECEPTION AREA: 383 SF CUSTOMERS AT PEAK: MAX 5 EMPLOYEE ONLY AREA: 3922 SF EMPLOYEES AT PEAK: MAX 5 GRAND TOTAL: 10 OCCUPANTS HEIGHT OF BUILDING: 15'-0" CONSTRUCTION TYPE - TYPE II B, NON SPRINKLERED U al PROJECT DARREN AND LUANN OWNER: DARRENCOCKERAM@HOUNDSTOWNUSA.COM LUANN@HOUNDSTOWNUSA.COM ARCHITECT: CORTLAND MORGAN ARCHITECT CORTLAND MORGAN 711 N. FIELDER ROAD ARLI NGTON TEXAS 76012 TEL: 817.635.5696 ENGINEER: DON PENN, P.E. DON PENN CONSULTING ENGINEER 1301 SOLANA BLVD. BLDG. 1 / SUITE 1420 W ESTLAKE, TX 76262 TEL: 817.410.2858 :i• SECTION MARKER ELEVATION MARKER SIM 1 j CALLOUT MARKER A101 q_ CENTERLINE MARKER PROJECT COORDINATOR: 6440 FORT KING ZEPHYRHILLS, FL 335 2 DOOR TAG GENERAL 0000 COVER SHEET G 101 LIFE SAFETY DEMO AD101 DEMO REVIEW DATE: CITY OF ZEPHYRHILLS BUILDING OFFICIAL ARCHITECTURAL A101 FLOOR PLAN & SCHEDULES A102 STOREFRONT & EQUIP PLATFORM A120 DETAILS AND MATERIAL SPECS A121 FINISH PLAN A122 FENCE PLAN AND DETAILS A130 WALL ELEVATIONS & DESK DETAIL A150 REFLECTED CEILING PLAN MECHANICAL M101 MECHANICAL PLAN ME1.1 ENERGY FORMS ELECTRICAL � E101 ELECTRICAL SPECIFICATIONS E102 ELECTRICAL POWER PLAN E103 ELECTRICAL LIGHTING PLAN Room name � 101 150 SF ROOM TAG 0 GEN TAG 7 DEMO NOTE <^>- WALL TAG (_�) PLAN NOTE W1 WINDOW � SPOT TAG ELEVATION 00 _ _ COLUMN GRID KDC CONSULTING INC. KEVI N CON RAD 3520 S 450 E ANDERSON, IN 46017 CONSTRUCTION BANYAN CONSTRUCTION SERVICES MANAGER: 35 WHITTINGTON DR. BROWNSBURG, IN 46112 JANSEN GEHRING TEL: 317.747.0555 PLUMBING P101 PLUMBING PLAN - WASTE P102 PLUMBING PLAN - WATER AFF AHU ANSI ARCH BLDG CATV CLG CLR CONC CONST CONTR CT DF DIM DISP EDF EP EEP EFD EXST EXT FD FLUOR GC GWB GYP HC HVAC INSUL INT LAV LOC MAX MIN NIC NTS OC OPNG PLAM PLBG PLYWD REQ RM TYP VAC VTR ABOVE FINISHED FLOOR AIR HANDLER UIT AMERICAN NATIONAL STANDARDS INSTITUTE ARCHITECTURAL BUILDING CABLE TELEVISION CEILING CLEAR CONCRETE CONSTRUCTION CONTRACTOR CERAMIC TILE DRINKING FOUNTAIN DIMENSION DISPENSARY EXISTING DRINKING FOUNTAIN REvirw OATS: ELECTRICAL PANEL CITY 0 KEPI-!YR ILL EXISTING ELECTRICAL PANEL BL91LD'`IA-3of"C1AL EXISTING FLOOR DRAIN EXISTING EXTERIOR FLOOR DRAIN FLUORESCENT GENERAL CONTRACTOR GYPSUM WALL BOARD GYPSUM HANDICAP (ED) HEATING/VENTILATION/AIR CONDITIONING INSULATION INTERIOR LAVATORY LOCATION(S) MAXIMUM MINIMUM NOT IN CONTRACT NOT TO SCALE ON CENTER 4OKK SHALL COMPLY WITH PREVAILING OPENING -'JDES FLORIDA BUILDING CODE, PLASTIC LAMINATE 'ATIONAL ELECTRIC CODE, -NID THE CITY OF ZEPHYRHILLS PLUMBING )RDINANCES PLYWOOD REQUIRED (REQUIREMENTS) , ROOM REVIEW DATE' TYPICAL CITY OF ZEPHYRHI S VACUUM FIRE AND LIFE SAFE NVER__ VENT THROUGH ROOF 3 ALL WORK SHALL COMPLY WITk NFFA CODES AND STANDARDS !J't 1. UNLESS OTHERWISE INDICATED, GENERAL NOTES APPLY TO ALL DRAWINGS IN THIS SET. 2. THESE DRAWINGS AND COPIES THEREOF ARE LEGAL INSTRUMENTS OF SERVICE FOR USE OF THE OWNER ONLY. 3. ANY DEVIATIONS FROM THE CONTRACT DOCUMENTS WHICH ARE NECESSITATED BY FIELD CONDITIONS SHALL BE BROUGHT TO THE ATTENTION OF THE OWNER 4. UNLESS OTHERWISE NOTED, ALL DIMENSIONS ARE TAKEN FROM BUILDING LINES, FACE OF STUD WALLS, FACE OF MASONRY, CENTERLINES, BACK OF CURBS, OR AT OTHER LOCATIONS INDICATED. 5. WALL TYPES ARE DESIGNATED ON THE FLOOR PLAN. 6. ALL WALLS SHALL EXTEND 6" ABOVE DESIGNATED CEILING HEIGHT UNLESS NOTED OTHERWISE. 7. PROVISIONS SHALL BE MADE AT ALL FULL HEIGHT NONBEARING WALL FOR 1-INCH VERTICAL MOVEMENT OF THE BUILDING STRUCTURE WITHOUT TRANSFER OF COMPRESSIVE LOADS TO WALL. FILL IRREGULARITIES BETWEEN TOP OF WALL AND DECK ABOVE WITH FIRE SAFING INSULATION OR FIRE STOPPING MATERIALS AS REQUIRED TO MEET FIRE RATING OF RESPECTIVE WALLS. 8. ALL PENETRATIONS THROUGH RATED DEMISING WALLS SHALL BE SEALED WITH FIRE STOPPING MATERIAL AS REQUIRED TO ACHIEVE THE RESPECTIVE FIRE -RESISTIVE RATING AND SMOKE STOPPAGE. 9. FIRE TREATED WOOD TO BE FURNISHED & INSTALLED. BLOCKING IN WALL PARTITIONS TO BE INSTALLED FOR THE PROPER ANCHORAGE OF ALL WALL ATTACHED ITEMS: I.E. TOILET ACCESSORIES, CABINETS, WALL -MOUNTED FIXTURES, CASEWORK, MILLWORK, ETC. ALL COMBUSTIBLE MATERIALS INCLUDING PLYWOOD SHALL EITHER BE FIRE RETARDANT TREATED WOOD OR OTHER APPROVED MATERIAL IN THE LOCATIONS AND APPLICATIONS AS PERMITTED BY IBC 603 SECTIONS 603.1.1 THROUGH 603.1.3 10. GYPSUM BOARD SURFACES SHALL BE ISOLATED WITH CONTROL JOINTS AS PER MANUFACTURERS REQUIREMENTS AND INDUSTRY STANDARDS. ALL GYPSUM BOARD SURFACES ARE TO BE FINISHED SMOOTH LEVEL 3 FINISH UNLESS OTHERWISE NOTED, WITH THE FOLLOWING ADDITION, ANY READILY VISIBLE IMPERFECTIONS IN GYPSUM BOARD SURFACE SHALL BE COATED WITH JOINT COMPOUND AND/OR SKIM -COATED AS REQUIRED. 11. ALL OWNER FURNISHED ITEMS TO BE INCLUDED, WHETHER OWNER INSTALLED OR CONTRACTOR INSTALLED IN THE CONSTRUCTION, AND SHALL COORDINATE WITH THE OWNER TO ACCOMMODATE THESE ITEMS. 12. PROJECT SITE TO BE VISITED PRIOR TO SUBMITTAL OF BID. SCOPE OF WORK TO BE ESTABLISHED FROM CONSTRUCTION DOCUMENTS AND ACTUAL PROJECT SITE VISIT. ANY OMISSIONS, DISCREPANCIES OR CLARIFICATIONS ARE TO BE BROUGHT TO THE IMMEDIATE ATTENTIONS OF THE OWNER. FAILURE TO PERFORM IN THIS MANNER DOES NOT ALLOW FOR ADDITIONAL COST TO THE OWNER. 13. DUST PARTITIONS TO BE PROVIDED AS NECESSARY TO CLOSE OFF AREA OF WORK FROM ACTIVE AREAS OF THE BUILDING. 14. SECURITY PARTITIONS TO BE PROVIDED AS NECESSARY TO SECURE AREAS OF THE BUILDING FROM UNAUTHORIZED ENTRY. 15. ALL CONTRACTORS INVOLVED IN THIS PROJECT SHALL REVIEW ALL DRAWINGS INCLUDED IN THIS DRAWING SET AND SHALL COORDINATE THEIR WORK WITH OTHER TRADES ON THIS PROJECT. 16. ALL AREAS DAMAGED OR MODIFIED AS THE RESULT OF CONSTRUCTION ACTIVITIES TO BE REPAIRED. 17. CONSTRUCTION SCHEDULE TO BE GENERATED AND ADHERED AFTER APPROVAL BY THE OWNER. 18. COORDINATE WITH MECHANICAL AND ELECTRICAL CONTRACTORS FOR ADDITIONAL REQUIRED EQUIPMENT AND SIZING. THIS WOULD INCLUDE ALL HVAC , ELECTRICAL AND PLUMBING. 19. ADHERE TO REQUIREMENTS OF SPECIFICATIONS FOR BUILDING SHELL PACKAGE TO ENSURE CONSISTENCY IN MATERIALS AND WORKMANSHIP. 20. ALL WORK SHALL CONFORM TO THE REQUIREMENTS WITHIN THE CURRENT EDITIONS OF ALL LOCAL, CITY, STATE AND FEDERAL APPLICABLE CODES ADOPTED BY THE LOCAL JURISDICTION. 21. SCOPE OF THE PROFESSIONAL SERVICES IS LIMITED TO THE TENANT IMPROVEMENT, AND DOES NOT ADDRESS THE BUILDING SHELL ELEMENTS, ROOF ASSEMBLY, WALL ASSEMBLY, FLOOR ASSEMBLY, ALL PENETRATIONS, INFILL AND ASSOCIATED DETAILING IS THE RESPONSIBILITY OF THE CONTRACTOR OR OTHERS. 22. EACH TRADE SHALL BE HELD RESPONSIBLE FOR KNOWLEDGE OF THE GENERAL NOTES INCLUDED THROUGHOUT THE CONTRACT DOCUMENTS AND THE APPLICABLE BUILDING CODES. 23. NOTED DIMENSIONS TAKE PRECEDENCE OVER SCALED DIMENSIONS, DO NOT SCALE DRAWINGS. 24. IN THE EVENT DISCREPANCIES OR CONFLICTS ARISE AMONG DRAWINGS AND/OR OTHER DESCRIPTIONS CONTAINED HEREIN, THE CONTRACTOR SHALL NOTIFY THE OWNER IMMEDIATELY FOR CLARIFICATION. 25. VERIFY AND COORDINATE ALL OPERATIONAL REQUIREMENTS AND CLEARANCE DIMENSIONS OF PROJECT COMPONENTS; INCLUDING CONTRACTOR SUPPLIED AND OWNER SUPPLIED ITEMS. THIS INCLUDED BUT IS NOT LIMITED TO THE FUNCTIONAL ASPECTS OF THE FOLLOWING: A. APPLIANCE, DISHWASHER, REFRIGERATOR, WASHER, DRYER, MICROWAVE, ETC. (I.E., DOOR OPERATION CLEARS ALL DOOR TRIM, CASED OPENING TRIM AND WALL MOUNTED ITEMS). B. ELECTRONIC DEVICES, COMPUTER, TELEVISION, DVD PLAYER, SOUND COMPONENTS, ETC. C. CABINETRY, HARDWARE, PULLS, SLIDES, ETC. COORDINATE AND ENSURE COMPLETE FREE AND CLEAR OPERATION OF DRAWERS AND DOORS. PROVIDE A 1 1/2" SCRIBE AT THE ENDS OF ALL CABINET RUNS ABUTTING ADJACENT WALL ASSEMBLIES TO ENSURE ADEQUATE CLEARANCES. 26. ALL COSTS TO BE ITEMIZED AND SCOPE OF WORK REGARDING ANY CHANGE ORDER. THIS INFORMATION MUST BE PRESENTED TO THE OWNER FOR APPROVAL PRIOR TO ANY WORK BEING EXECUTED. 27. ALL LIGHT FIXTURES THAT COME INTO CONTACT WITH BUILDING INSULATION MUST BE IC RATED. ALL LIGHT FIXTURES SHALL MEET ALL APPLICABLE CODES FROM NATIONAL ELECTRIC CODE (NEC) TO THE INTERNATIONAL ENERGY CODE (IEC). CONTRACTOR IS TO VERIFY CODE COMPLIANCE OF ALL LIGHT FIXTURES. 28. ALL MECHANICAL CHASE SIZES TO BE COORDINATED WITH THE MECHANICAL CONTRACTOR. 29. ALL ELECTRICAL SWITCHING TO BE LOCATED TO OPERABLE SIDE OF DOOR OPENINGS AND AS SHOWN ON THE PLANS. THIS INCLUDES SWITCHED OUTLETS AND LIGHT FIXTURES. ANY DEVIATIONS TO BE BROUGHT TO THE ATTENTION OF THE OWNER FOR CLARIFICATION. 30. ANY SHUT DOWN OF THE FIRE PROTECTION SYSTEM WILL REQUIRE NOTICE TO ALL OTHER TENANTS WITHIN THE SYSTEM AND SHALL BE COORDINATED WITH THE LANDLORD. 31. IF A CONFLICT/DISCREPANCIES OCCUR BETWEEN THE DESIGN DRAWINGS, ENGINEER DRAWINGS AND/OR SPECIFICATIONS, THE MORE STRINGENT & EXPANSIVE OPTION SHALL BE PERFORMED BY THE CONTRACTOR. 32. EXISTING TENANT DEMISING WALLS MAY BE FIRE -RESISTANCE RATED ASSEMBLIES. G. C. TO VERIFY RATING OF PARTITIONS ABOVE CORRIDOR CEILING AND MAINTAIN RATING AS NECESSARY. 33. ALL INTERIOR FINISHES SHALL MEET THE FLAME SPREAD AND SMOKE DEVELOPMENT AS SPECIFIED IN IBC 801.1.1; INTERIOR FINISHES. MANUFACTURER'S SPECIFICATIONS FOR INTERIOR FINISHES SHALL BE PROVIDED TO THE BUILDING CODE OFFICIAL UPON REQUEST. i'll U U 0 1 W±l MMI 0 =91(91 I 2020 FLORIDA BUILDING CODE, 7TH EDITION (FBC) 2020 FBC - PLUMBING, 7TH EDITION 2020 FBC - MECHANICAL, 7TH EDITION 2020 FBC - RESIDENTIAL CODE, 7TH EDITION 2020 FBC - FUEL GAS, 7TH EDITION 2020 FFPC, 7TH EDITION 2020 FBC - ENERGY CONSERVATION, 7TH EDITION NATIONAL ELECTRICAL CODE 2017 OF FLORIDA (NEC) ONN"01 I I M&M: 1. NO SMOKING - ALL JOB SITES ARE SMOKE FREE. 2. PROVIDE DAILY BROOM SWEEP & GENERAL DAILY CLEAN UP (DUMPSTER PROVIDED). 3. SUBMIT SIGNED SCOPE TO BCS WITH SUBMITTAL BID (NEEDS SIGNED BY ALL PARTIES BEFORE STARTING WORK) 4. SUBMIT COPY OF W-9 TO BCS (BEFORE START OF WORK) (1.4.1 LINK -FORM W-9-IRS.GOV.) 5. SUBMIT COPY OF CERTIFICATE OF INSURANCE TO BCS & LIST BCS AS ADDITIONAL INSURED & CERTIFICATE HOLDER (BEFORE START OF WORK). 6. SUBMIT WORKER'S COMPENSATION EXEMPTION CERTIFICATE WAIVER OR WORKER'S COMPENSATION CERTIFICATE TO BCS (BEFORE START OF WORK). A. 1.6.1 IF YOU'RE NOT REQUIRED TO CARRY WORKERS COMPENSATION THEN PLEASE PROVIDE THE EXEMPTION CERTIFICATE. B. 1.6.2 EXAMPLE OF ABOVE FORMS (FROM INDIANA - YOUR STATE MAY HAVE DIFFERENT REGULATIONS)- COI FORM/WC FORM 7. ALL OSHA RULES APPLY AND MUST BE FOLLOWED AT ALL TIMES. 8. JOB SITE HOURS ARE FROM 7 AM TO 3:30 PM UNLESS AUTHORIZED BY GC. C O R L A N G R G A N i A P� C H E P 711 N. FIELDER RD. ARLINGTON, TX 76012 PH: (817) 635.5696 FAX: (817) 635.5699 CERTIFIED BY: �i� of-Fkq C!' '�\_AND Mp 9 o� Rc A R-00 I ,w_ '( TF/'ED ARG� CORTLAND MORGAN FLORIDA REG. AR - 0015586 DRAWN BY: STAFF 90% h RIM TM T Aa" W own 6440"-F&T KhNG ZE PffYfZMtLS, F L 33542 39( DARREN & LUANN Owner BANYAN CONSTRUCTION JANSEN GEHRING 317.747.0555 ZEPHYR HILLS COVER SHEET 0' - 0 3/17/2022 4:14:18 PM { z 0 (a) 60" DIAMETER SPACE z M 3'-0" Ll1'-0" i I I I I I I 1 I I J I I I I I I I I I MFP- (b) T-SHAPE SPACE FOR 180 DEGREE TURN z � I I 00 I --L --� 18" MIN PICTOGRAM TO COMPLY WITH 703.6 WOMEN SYMBOL OF ACCESSIBILITY TO COMPLY WITH 703.7 TEXT NOT IN PICTOGRAM FIELD (518" TO 2" TALL) GRADE 2 BRAILLE NOTES: 1. WHERE A TACTILE SIGN IS REQUIRED, SIGN IS TO BE ON LATCH SIDE OF DOOR, COMPLY WITH 703.4.2 2. ACCESSIBLE SIGNAGE TO COMPLY WITH ADA 703 3. SIGN TO COMPLY WITH 703.4.1 PULL SIDE r w U) I 0 U z O 1 1 x I I 0 o z � � I OLL o T 2'-0"MIN I 32" MIN CLR PUSH SIDE r I I I I z � I I I I T 1 2'-0"MIN ih I I I I 32" MIN CLR LATCH SIDE APPROACHES LAVATORY .I 0'-8" O M ci I J i, (V N 0'-11' CV 1' - 5" MIN 2'- 6" MIN PULL SIDE PUSH SIDE I I I I I I I I I o I i i 1' - 0" MIN IF DOOR ON CLOSER I I I I 32" MIN CLR FRONT APPROACHES HAND BLOW DRYER 4" PROJECTION MAX MIRROR LAVATORY �L X Q C) ' iy) N M GRAB BARS 3'-0" 0'-6" M cy) 0 CM ti TOILET PULL SIDE r----------- -----------------1-� I I I I I I I z X=3'-6"MIN I icyow } v 1F Y = 4'-6" MINI X=3'-0"MIN I I I IFY=5'-0"MIN f I 32" MIN CLR I I I I z I I g I I I I -------------- 2'- 0" MIN i I 32" MIN CLR HINGE SIDE APPROACHES ' - 0" MAX T- 7 7"- 9" 1 N I I I a) — - r- fM TOILET TOILET PAPER DISPENSER GRAB BARS cf) co c,`� ,) Cy) 1. ALL GUEST ROOMS, MEETING ROOMS, AND OTHER COMMON AREA 1. DO NOT SCALE DRAWINGS. ROOMS SHOULD PROVIDE SIGNAGE IN COMPLIANCE WITH 2. ALL DOORS IN THE MEAN OF GUIDELINES 3, 4, 5, 6, AND 7 BELOW. 2. DIRECTIONAL SIGNAGE - MUST BE LOCATED AT AN INACCESSIBLE EGRESS SHALL BE SINGLE ELEMENT WHICH DIRECTS INDIVIDUALS WITH DISABILITIES TO THE ACTION RELEASE AND NEAREST ACCESSIBLE ELEMENT. SHALL NOT REQUIRE TH E 3. CHARACTER PROPORTION - LETTERS AND NUMBERS ON SIGNS USE OF A KEY, TOOL, OR SHALL HAVE A WIDTH TO HEIGHT RATIO BETWEEN 1:5 AND 1:10. 4. CHARACTER HEIGHT - CHARACTERS AND NUMBERS ON SIGNS SPECIAL KNOWLEDGE TO SHALL BE SIZED ACCORDING TO THE VIEWING DISTANCE FROM OPEN FROM EGRESS SIDE. WHICH THEY ARE TO BE READ. THE MINIMUM CHARACTER HEIGHT 3 EXIT AND EMERGENCY SHOULD BE THREE INCHES. 5. RAISED AND BRAILLE CHARACTERS AND PICTORIAL SYMBOLS LIGHTS SHALL BE FULLY SIGNS (PICTOGRAMS) - LETTERS AND NUMERALS SHALL BE RAISED OPERABLE AT THE TIME OF 1/32". UPPERCASE, SANS SERIF OR SIMPLE SERIF TYPE SHALL BE THE FIRE FINAL ACCOMPANIED WITH GRADE 2 BRAILLE. RAISED CHARACTERS INSPECTION. SHALL BE AT LEAST 5/8" HIGH, BUT NO HIGHER THAN TWO INCHES. PICTOGRAMS SHALL BE ACCOMPANIED BY THE EQUIVALENT 4. ALL INTERIOR FINISHES TO VERBAL DESCRIPTION PLACED DIRECTLY BELOW THE COPMLY WITH LSC 101, PICTOGRAMS. THE BORDER DIMENSION OF THE PICTOGRAM SHALL CHAPTER 10 SEC. 10.2. BE SIX INCHES MINIMUM IN HEIGHT. 6. FINISH AND CONTRAST - THE CHARACTERS AND BACKGROUND OF 5. ALL EMERGENCY LIGHTS SIGNS SHALL BE EGGSHELL MATTE OR OTHER NO GLARE FINISH AND EXIT SIGNS SHALL CHARACTERS AND SYMBOLS SHALL CONTRAST WITH THEIR HAVE BATTERY BACKUP. BACKGROUND - EITHER LIGHT CHARACTERS ON A DARK BACKGROUND OR DARK CHARACTERS ON A LIGHT BACKGROUND. 6. ALL PORTIONS OF THE 7. MOUNTING LOCATION AND HEIGHT - WHERE PERMANENT BUILDING SHALL BE WITHIN IDENTIFICATION IS PROVIDED FOR ROOMS AND SPACES, SIGNS 75 FT OF TRAVEL DISTANCE SHALL BE INSTALLED ON THE WALL ADJACENT TO THE LATCH SIDE TO AN EXTINGUISHING UNIT OF THE DOOR. WHERE THERE IS NO WALL SPACE TO THE LATCH SIDE OF THE DOOR, INCLUDING DOUBLE LEAF DOORS, SIGNS OR AS REQUIRED BY LOCAL SHALL BE PLACED ON THE NEAREST ADJACENT WALL. MOUNTING FIRE MARSHALL. HEIGHT SHALL BE 60" ABOVE THE FNISHED FLOOR TO THE 7 EMERGENCY LIGHTING TO CENTERLINE OF THE SIGN. MOUNTING LOCATION FOR SUCH SIGNAGE SHALL BE SO THAT PERSON MAY APPROACH WITHIN BE VERIFIED FOR PROPER THREE INCHES OF SIGNAGE WITHOUT ENCOUNTERING WORKING CONDITION, PROTRUDING OBJECTS OR STANDING WITHIN THE SWING OF THE BATTERY BACKUP IS DOOR. REQUIRED TO MAINTAIN m.. . I LIGHTING FOR A MIN. OF 90 MINUTES AT A MINIMUM THE PROJECT CONSISTS OF AN INTERIOR TENANT REMODEL TO ILLUMINATION OF 1 CONSTRUCT A DOG DAYCARE FACILITY. BACK OF HOUSE IS EMPLOYEE FOOTCANDLE AS PER IBC - ONLY AND WILL HAVE NO PUBLIC ACCESS. THE RECEPTION 1S SECTION 1008. RESTRICTED PUBLIC ACCESS FOR PEOPLE TO DROP OFF AND PICK UPTHEIR DOGS IN THE MORNING AND EVENINGS. THERE WILL BE A MAX NUMBER OF FIVE EMPLOYEES DURING OPERATION. THE RECEPTION AREA CONSTITUTES LESS THAN 25% OF THE TOTAL AREA OF THE SPACE. PROPOSED USE: DOG DAYCARE OWNER'S AUTHORAIZED AGENT: JANSEN GEHRING TEL: 317.747.0555 OWNED BY A PRIVATE OWNER LEAD DESIGN PROFESSIONAL: CORTLAND MORGAN CODE: 2020 FBC GROSS PROJECT AREA - 4305.45 SF OCCUPANT LOAD - MAX 10 USE GROUP - B HEIGHT OF BUILDING - 15'-0" CONSTRUCTION TYPE - TYPE II B, NON SPRINKLERED FIRE PROTECTION REQUIREMENTS ROOF SYSTEM - EXISTING TO REMAIN BEARING WALLS - NON-COMBUSTIBLE STRUCTURAL FRAME - NON-COMBUSTIBLE NON -BEARING WALLS - NON-COMBUSTIBLE MATERIAL LIFE SAFETY REQUIREMENTS EMERGENCY LIGHTING - YES EXIT SIGNS - YES FIRE ALARM - YES - DEFERRED SUBMITTAL STRUCTURALLOADS APPROVED BY ORIGINAL BUILDING PERMIT - TENANT BUILD -OUT DOES NOT ALTER BUILDING STRUCTURAL SYSTEM. 2020 FLORIDA BUILDING CODE, 7TH EDITION (FBC) 2020 FBC - PLUMBING, 7TH EDITION 2020 FBC - MECHANICAL, 7TH EDITION 2020 FBC - RESIDENTIAL CODE, 7TH EDITION 2020 FBC - FUEL GAS, 7TH EDITION 2020 FFPC, 7TH EDITION 2020 FBC - ENERGY CONSERVATION, 7TH EDITION NATIONAL ELECTRICAL CODE 2017 OF FLORIDA (NEC) ACCESSIBILITY CODE: [CC/ANSI 117.1-2009 CONSTRUCTION TYPE CLASSIFICATION: TYPE H B FIRE SPRINKLER SYSTEM: NO TRAVEL DISTANCE (B): 200' MAX ALLOWED COMMON PATH: 75' MAX ALLOWED DEAD END CORRIDOR: 20' MAX ALLOWED TOTAL DIAGONAL LENGTH: = 104' - 1" MIN. ALLOWED EXIT REMOTENESS: = 52' - 1/2" PROVIDED EXIT REMOTENESS: = 78' - 0 7/8" EGRESS WIDTH REQUIRED: 32" (x2) EGRESS WIDTH PROVIDED: 32" (x4) ACCESSIBLE PARKING APPROVED BY ORIGINAL BUILDING PERMIT -TENANT BUILDOUT DOES NOT ALTER PARKING ON SITE. B OCCUPANCY (10 PEOPLE) WATER CLOSET: 1 REQUIRED, 1 PROVIDED LAVATORY: 1 REQUIRED; 1 PROVIDED FIRE EXTINGUISHER SPECIFICATION LARSEN - CAMEO SERIES MODEL #SS C2409-R (OR APPROVED EQUAL W/ ANNUAL SERVICE TAGS. MOUNTING HEIGHTS - SEE DETAIL THIS SHEET A. ADA GUIDLINES TO SPECIFY REACH RANGES FOR BUILDING OCCUPANTS WHO REQUIRE ACCESS TO EQUIPMENT SUCH AS FIRE EXTINGUISHERS AND OTHER FIRE SAFETY DEVICES. B. FOR AN UNOBSTRUCTED APPROACH, THE MAXIMUM FORWARD REACH TO THIS EQUIPMENT (FOR EXAMPLE, THE FIRE EXTINGUISHER HANDLE) IS 48" ABOVE THE FLOOR. THE MAXIMUM SIDE REACH FOR SUCH AN APPROACH IS 54". THE ACTUAL MOUNTING HEIGHTS FOR CABINETS HOUSING THIS EQUIPMENT CAN BE DETERMINED BY REVIEWING THE EXACT DIMENSIONS OF THE SPECIFIED CABINET AND THE POSITIONING OF THE FIRE EQUIPMENT WITHIN THAT CABINET. PLEASE NOTE THAT THESE ADAAG REACH RANGE REQUIREMENTS FALL WITHIN THE NFPA (NATIONAL FIRE PROTECTION ASSOCIATION) GUIDELINES. THE NFPA GUIDELINES STATE THAT THE DISTANCE FROM THE FLOOR TO THE TOP OF THE FIRE EXTINGUISHER TO BE NO MORE THAN 5'. C. FIRE EXTINGUISHER SIGNS SHALL BE LOCATED BY ALL EXIT DOORS AND EVERY 75' THEREAFTER. FIRE EXTINGUISHERS ARE TO BE LOCATED SUCH THAT TRAVEL DISTANCE DOES NOT EXCEED 75'. D. MOUNTING BRACKET AT HEIGHT REQUIRED TO PERMIT FIRE EXTINGUISHER ACCESS AT 48" MAX. AFF. FIRE EXTINGUISHERS SHALL BE LOCATED PER THE REQUIREMENTS OF NFPA 10, CHAPTER 10, CURRENT EDITION. E. THE SIZE SHALL BE A MINIMUM OF 2 A_10_B/C. F. EXACT NUMBER AND LOCATIONS FOR REQUIRED FIRE EXTINGUISHERS TO BE DETERMINED BY THE GC AT THE DISCRETION OF THE FIRE INSPECTOR FOR THE JURISDICTION ISSUING THE PERMIT FOR THIS PROJECT. G. F.E. - FIRE EXTINGUISHERS SHALL BE 5LB ABC TYPE AT LOCATIONS INDICATED. C 0 R I L A NI D m 0 R G A NI ARCH LC 711 N. FIELDER RD. ARLI NGTON, TX 76012 PH: (817) 635.5696 FAX: (817) 635.5699 CERTIFIED BY: ;U A R-0015586 ; rj r ED A CORTLAND MORGAN FLORIDA REG. AR - 0015586 D RAW N BY: STAFF 90% � rM 6440 FORT KING ZEPHYRHILLS, FL 33542 DARREN & LUANN Owner min CONSTRUCTION JANSEN GEHRING 317.747.0555 W391mm-9:a:IIIIK LIFE SAFETY LIFE SAFETY PLAN 3/16 1'-0" — - EXIT ACCESS PATH • START OF EXIT PATH _ DIAGONAL DISTANCE OF SPACE G101 3/17/2022 4:14:19 PM ti 1/4- 1. GC IS TO PROTECT ALL EXISTING ITEMS TO REMAIN (SUCH AS MILLWORK, FLOORING, TRIM, ETC) THROUGHOUT THE COURSE OF THE JOB. ALL SURFACES AND FINISHES TO REMAIN UNLESS NOTED. IF DAMAGED DURING DEMOLITION OR ANY STAGE OF WORK, SHALL BE REPAIRED BY THE GC AT HIS EXPENSE TO "LIKE NEW" CONDITION. 2. REMOVAL OF WALLS TO INCLUDE PATCHING AND PREPING FOR NEW FINISHES AT ADJACENT WALLS WHERE IMPACTED BY DEMOLITION. 3. GYPSUM BOARD WALLS TO BE TAPED, SANDED, AND FINISHED TO MATCH EXISTING UNLESS OTHERWISE NOTED. 4. GC IS RESPONSIBLE FOR THE REMOVAL OF EXISTING FINISH FLOORING DOWN TO THE SLAB, SUBFLOOR, OR WOOD FLOOR JOISTS IN ALL AREAS WHERE NEW FLOORING IS SPECIFIED. 5. GC IS TO REMOVE ALL INACTIVE PIPES, DUCTS, AND ANCHORS WHICH ARE NOT TO BE USED AND PATCH SURFACES TO FLAT CONDITION. 6. DO NOT REMOVE ANY EMERGENCY OR FIRE PROTECTION SIGNALS AND EQUPMENT U.O.N. PROTECT AS REQUIRED FOR DURATION OF THE JOB. NO ACTIVE SMOKE DETECTORS SHALL BE COVERED OR OTHERWISE RENDERED INEFFECTIVE. 7. RELOCATE EXISTING ACTIVE OUTLET BOXES, JUNCTION BOXES, ETC., WHICH ARE RENDERED INACCESSIBLE BY NEW CONSTRUCTION. DEMO NOTES 1 DEMO AND REMOVAL OF OVERHEAD DOORS, COMPLETE. PREP FOR INFILL AND INSTALLATION OF NEW DOORS OR STOREFRONT. 2 EXISTING OPENING TO BE PARTIALLY FILLED AND PREPPED FOR NEW CASED OPENING. SEE A101. 3 WALL TO BE CUT FOR NEW OPENING. 4 REMOVE DOOR AND SALVAGE FOR USE IN NEW CONSTRUCTION. 5 SEAL DOORS SHUT AND PREP FOR CONSTRUCTION. 0 0I L A 1\l D M 0 P� G A N ARCH T LD 711 N. FIELDER RD. ARLI NGTON, TX 76012 PH: (817) 635.5696 FAX: (817) 635.5699 CERTIFIED BY: p,ND Iy0� �O .,V AR-001558) h V U RED AR CORTLAND MORGAN FLORIDA REG. AR - 0015586 D RAW N BY: STAFF 90% 6440 FORT KING ZEPHYRH I LLS, FL 33542 0mll WSWV40-4 111 01 Owner mm-1 :1 L 101 CONSTRUCTION JANSEN GEHRING 317.747.0555 ZEPHYR HILLS EXST WALL TO REMAIN WALL (COMPLETE) TO DEMO BE DEMOLITIONED DOOR AND FRAME TO 1 - BE DEMOLITIONED DEMO PLAN EXST DOOR TO REMAIN 1 /4" = 1'-0" 3/17/2022 4:14.16 PM 2 x 4 ACOUSTICAL CEILING TILE 2 x 4 LIGHT FIXTURE SEE SCHEDULE 8' LED STRIP LIGHT ••R PLAN NEW CONSTRUCTION C 0 R I L A I\i D m 0 R G A ICI ARC H C C I 711 N. FIELDER RD. ARLINGTON, TX 76012 PH: (817) 635.5696 FAX: (817) 635.5699 CERTIFIED BY: ®9�\'AND 1Vlo,, ?° . eC' A!2-i)(i E 558 �,?ED RAG CORTLAND MORGAN FLORIDA REG. AR - 0015586 D RAW N BY: STAFF 90% 6440 FORT t DARREN & LUANN Owner CONSTRUCTION JANSEN GEHRING 317.747.0555 ZEPHYR HILLS EXST CONSTRUCTION CEILING DEMO YqNEW DOOR AND FRAME PLAN TO BE INSTALLED CEILING DEMO PLAN 114" = 1'-0" EXST DOOR AND FRAME PORCH LIGHT 3/17/2022 4:14:18 PM WINDOW ELEVATIONS 1/2" = 1'-0" Window Schedule W1 LOBBY WINDOW 2' - 0" 7' - 0" W2 GROOMING WINDOW 2' - 0" 5' - 0" TWO T-0" DOORS ,i ENTRY DOOR FENCE SCHEDULE F1 VESTIBULE FENCING F2 5' FENCE PANEL F3 6' FENCE PANEL F4 8' FENCE PANEL WALL AND PARTITION SCHEDULE WALL TYPE WALL STRUCTURE; SEE DETAILS ON A120 Al 20 GA 3 5/8" MTL STUD 16" OC W/ 1 LAYER OF MOISTURE RESISTANT GWB EACH SIDE A2 20 GA 3 5/8" MTL STUD 16" OC W/ 1 LAYER OF 1/2" MOISTURE RESISTANT GWB EACH SIDE A3 20 GA 2 1/2" MTL STUD 16" OC W/ 1 LAYER OF MOISTURE RESISTANT GWB ON INTERIOR SIDE. WALL ONLY EXTENDS 5' AFF. RETURNED WITH GYP BOARD BACK TO EXISTING WALL AT TOP. A4 18 GA 3 5/8" MTL STUD 16" OC W/ 1 LAYER OF 5/8" MOISTURE RESISTANT GWB EACH SIDE. WALLS ONLY EXTEND TO MEZZANINE HEIGHT. A4.1 18 GA 3 5/8" MTL STUD 16" OC W/ 1 LAYER OF 5/8" MOISTURE RESISTANT GWB ON INTERIOR SIDE. WALLS ONLY EXTEND TO MEZZANINE HEIGHT. A5 TWO CHANNELS OF 20 GA 2 1/2" MTL STUD 16" OC W/ GWB ON INTERIOR FACING SIDES A6 TWO CHANNELS OF 20 GA 2 1/2" MTL STUD 16" OC W/ GWB ON INTERIOR FACING SIDE AND EIFS FINISHED TO MATCH EXISTING FINISH ON EXTERIOR A7 FEATURE WALL; FINISH TO BE SELECTED BY OWNER. F3 6' VINYL FENCE PANEL SF1 NEW STOREFRONT; SEE Al02 ,, , , , , SUITE DOOR Suite Schedule Name Area Count STD 368 SF 23 LUX 139 SF 7 DBL 61 SF 2 TYPE ENTRY DOOR SUITE DOOR PASSAGE DOOR RESTROOM DOOR SALVAGED EXTERIOR DOOR 568 SF 32 �s 0 � 0 �Ec3Qi�i a zC T-0" PASSAGE DOOR T-0" RESTROOM DOOR , , , , , T-0" SALVAGED EXTERIOR DOOR DOOR AND FRAME ELEVATIONS 1 /2" = 1'-0" DOOR HARDWARE SCHEDULE HW SET HANDLE CLOSER DEADBOLT KICKPLATE PANIC ENTRY/EXIT YES PASSAGE LEVER NO NO NO NO SUITE PUSH/PULL PLATE NO YES NO NO Door Schedule Height MAT Finish MAT FINISH HEAD JAMB SILL HW SET Count T - 0" STOREFRONT ENTRY/EXIT 1 6'- 8" FIBERGLASS VINYL PT-3 H1 J1 S1 SUITE 32 6'- 8" FIBERGLASS VINYL PT-3 H1 J1 S1 OR S2 PASSAGE 7 6'- 8" FIBERGLASS VINYL PT-3 H1 J1 S1 PASSAGE 1 7' - 0" EXISTING EXISTING ENTRY/EXIT 1 VERIFY ALL DIMENSIONS, SQFT, AND COUNTS IN FIELD OR BEFORE INSTALL. 1. THE EXISTING DEMISING 1. GC IS TO PROTECT ALL WALL(S) MAY BE RATED EXISTING ITEMS TO REMAIN ASSEMBLY - U.L. THIS (SUCH AS MILLWORK, PARTITION IS REQUIREDTO FLOORING, TRIM, ETC) PROVIDE A CONTINUOUS THROUGHOUT THE COURSE MIN SEPARATION FROM OF THE JOB. ALL SURFACES TENANT SPACE TO ALL AND FINISHES TO REMAIN ADJACENT SPACES. GC TO UNLESS NOTED. IF VERIFY RATING OF DAMAGED DURING PARTITION ABOVE DEMOLITION OR ANY STAGE CORRIDOR CEILING AND OF WORK, SHALL BE MAINTAIN RATING AS REPAIRED BY THE GC AT NECESSARY. HIS EXPENSE TO "LIKE 2. PARTITION SUPPORT NEW" CONDITION. KICKERS ARE NOT TO BE 2. REMOVAL OF WALLS TO VISIBLE FROM HALLWAYS INCLUDE PATCHING AND AND OTHER PUBLIC PREPING FOR NEW SPACES. FINISHES AT ADJACENT 3. ALL WALLS SHALL EXTEND WALLS WHERE IMPACTED 6" ABOVE DESIGNATED BY DEMOLITION. CEILING HEIGHT UNLESS 3. GYPSUM BOARD WALLS TO NOTED OTHERWISE. BE TAPED, SANDED, AND 4. SUPPORT KICKERS TO FINISHED TO MATCH STRUCTURE OR TO EXISTING UNLESS PERPENDICULAR OTHERWISE NOTED. PARTITION WALL. 4. GC IS RESPONSIBLE FOR 5. NO EXPOSED DRYWALL UP THE REMOVAL OF EXISTING TO 5' IN ANY PLAYROOM FINISH FLOORING DOWN TO INTERIORS. SEE DETAIL THE SLAB, SUBFLOOR, OR FOR FINISHING SPEC. WOOD FLOOR JOISTS IN 6. ALL CINDERBLOCK WALLS ALL AREAS WHERE NEW NEW OR EXISTING MUST BE FLOORING IS SPECIFIED. SEALED AND FINISHED. 5. GC IS TO REMOVE ALL 7. ALL INT SUITE PARTITIONS INACTIVE PIPES, DUCTS, TO BE 6' IN HEIGHT. AND ANCHORS WHICH ARE 8. EXT SUITE GYP WALLS NOT NOT TO BE USED AND TO REACH CEILING TO PATCH SURFACES TO FLAT ALLOW AIRFLOW. SEE CONDITION. DETAIL FOR WALL HEIGHTS. 6. DO NOT REMOVE ANY 9. ALL INTERIOR WALLS TO BE EMERGENCY OR FIRE WALL TYPE Al UNLESS PROTECTION SIGNALS AND OTHERWISE NOTED. EQUPMENT U.O.N. PROTECT 10. ALL WALLS WITH SUITE AS REQUIRED FOR DOORS INSTALLED SHALL DURATION OF THE JOB. NO BE WALL TYPE A2. ACTIVE SMOKE DETECTORS SHALL BE COVERED OR OTHERWISE RENDERED FLOORING • INEFFECTIVE. 7. RELOCATE EXISTINGACTIVE 1. BANYAN CS FLOORING OUTLET BOXES, SCOPE NEEDS TO BE JUNCTION BOXES, ETC., SIGNED BEFORE ANWORK Y WHICH ARE RENDERED BEGINS. INACCESSIBLE BY NEWCONSTRUCTION. 2. REFER TO BUDGET. IF YOU HAVE EXCESSIVE FLOOR, SEND UP RED FLAG. 3. FLOOR PREP AND GENERAL DOOR NOTES SWEEP TO BE COMPLETED BEFORE INSTALL. 1. ALL NEW INTERIOR DOORS 4. NO SWEEPING DURING TO BE LEVER TYPE DOOR INSTALL - VACUUM ONLY. HANDLE WITH EXCEPTION 5. FLOORING MUST RUN OF THE 'SUITES'. THESE UNDER ALL CABINETS. ARE PUSH/PULL. 6. GROUT MUST BE WIPED 2. ALL DOORS PROVIDE 32" OFF IMMEDIATELY AFTER CLEAR WIDTH IN THE FULLY APPLYING. OPENED POSITION AND ARE 7. FLOOR CLEANOUTS & READILY OPENABLE FROM FLOOR DRAINS MUST BE EGRESS SIDE WITHOUT LEVEL. DO NOT GROUT KEY, SPECIAL KNOWLEDGE UNTIL LEVEL. OR EFFORT. 8. ALL CERAMIC TILE MUST BE 3. ALL HARDWARE FINISHES SEALED PRESSED TILE IN A TO BE BRUSHED SATIN NEUTRAL, LIGHT COLOR NICKEL FINISH UNLESS AND WITH LIGHT COLORED OTHERWISE NOTED. GROUT. 4. ALL EGRESS DOORS (NEW 9. LVP NOT TO BE USED IN OR EXISTING) LEADING TO ANY AREA DESIGNATED THE EXTERIOR OF THE FOR ANIMALS (IE BUILDING ARE TO HAVE PLAYROOMS, SUITES, SIGNS ON THEM STATING GROOMING, LEASH). THIS DOOR TO REMAIN 'UNLOCKED DURING NOTESINSTALL BUSINESS HOURS". 5. VERIFY THAT ALL LOCK 1. PORCH LIGHTS ON SUITES KEYED CYLINDER(S) SHALL TO BE INSTALLED ON BE OF THE TYPE THAT CENTER BETWEEN DOOR ACCEPTS INDUSTRY FRAMES. STANDARD "SMALL FORMAT 2. ALL PLAYROOM FENCING INTERCHANGEABLE CORES" TO BE 5' HIGH UNLESS (E.G. FALCON, ARROW, NOTED OTHERWISE. BEST, ETC). CONTRACTOR 3. ALL PLAYROOM FENCE SHALL INSTALL SAID LOCKS GATES TO BE T MIN WIDTH WITH CONTRACTOR'S OWN AND MATCH ADJACENT CORES AND QUANTITY OF FENCE HEIGHT. KEYS REQUIRED FOR 4. ALL PLAYROOM GATES TO CONTRACTOR PURPOSES HAVE SELF -CLOSING DURING CONSTRUCTION. HINGES. 6. ALL INTERIOR DOORS TO 5. BASE OF PLAYROOM FENCE HAVE THRESHOLDS RAIL TO BE MAX 1" AFF. REMOVED BEFORE INSTALL. 7. ALL STANDARD SUITE PLAN NOTES DOORS TO BE CENTERED ON SUITE SPACE. 1 BLACK OUT BOTTOM OF 8. PASSAGE DOORS TO USE WINDOW UP TO 5`. BAR S1 WHERE TILE FLOOR IS ACROSS ON INTERIOR. SEE UNINTERRUPTED BETWEEN DETAIL. SPACES. S2 TO BE USED 2 SEAL DOORS SHUT AND WHERE LVP TRANSITIONS BLACK OUT DOOR GLASS UP TO TILE FLOORING. TO 5'. SEE DETAIL 3 REUSE SALVAGED DOOR. SUITE NOTES SEE DEMO NOTE 4 ON AD101. 4 18" VIEWING PLATFORM. SEE 1. ALL STD (STANDARD) DETAIL ON A121. SUITES ARE 4'-0" x 4'-0" UNO. 2. ALL LUX (LUXURY) SUITES 5 4" x 4" x 10' STEEL POST ARE 4'-0" x 5'-0" UNO. CORE DRILLED 2'. FINISH 3. SEE FINISH SCHEDULE AND HEIGHT 8' AFF TO ANCHOR FINISH PLAN FOR DETAILS. A2 WALL 6 ADA RAMP. SLOPE TO MEET ADA REQUIREMENTS. VERIFY HEIGHT DIFFERENCE IN FIELD AND PROVIDE 12" OF RAMP FOR EVERY 1" OF RISE. FLOOR NEW DOOR AND FRAME TO BE INSTALLED EXST DOOR AND FRAME PORCH LIGHT VL- C 0 R I L A N 0 M 0 R G A IN ARC H I H C 711 N. FIELDER RD. ARLINGTON, TX76012 PH: (817) 635.5696 FAX: (817) 635.5699 CERTIFIED BY: ,LAND Mph, , o y, 'U All-OO15586 sTFh'ED ARG CORTLAND MORGAN FLORIDA REG. AR - 0015586 D RAW N BY: STAFF 90% 1 f TtvtTOWN 6440 FORT KING ZEPHYRHILLS, FL 33542 DARREN & LUANN Owner Mimi vi M IL CONSTRUCTION JANSEN GEHRING 317.747.055-5 ZEPHYR HILLS FLOOR PLAN & SCHEDULES FLOOR PLAN 1 /4" = 1'-0" 3/17/2022 4:14:04 PM 3/4" T GLt S( 6" 20 GA STRUCT M7 BACK TO BAC TOE STOP LESS LADDER "H GUARDRAILS C O RI L A N D m 0 R G A I� ARC N I F C 711 N. FIELDER RD. ARLI NGTON, TX 76012 PH: (817) 635.5696 FAX: (817) 635.5699 CERTIFIED BY: � .�C- ®F �F`n ,a \,AND Mo/�C ' 9 Aid-131i1558 ' cosC1 w y rr ED AR CORTLAND MORGAN FLORIDA REG. AR - 0015586 D RAW N BY: STAFF 90% DARREN & LUANN Owner ■ Imi k VINIL CONSTRUCTION JANSEN GEHRING 317.747.0555 ZEPHYR HILLS STOREFRONT & EQUIP PLATFORM EQUIP PLATFORM FLOOR DETAIL 6„ = 1'-0" EQUIPMENT PLATFORM PERSPECTIVE EQUIPMENT PLATFORM PLAN 1" = 1'-0" 1111 1 1- - - - -- 3/17/2022 4:14:06 PM PLAN I I I CODE ITEM Manufacturer Description Comments REQ/REC I EXISTING CMU WALL WIDTH -zle 20 GA 2 1/2" MTL STUD • EIFS FINISHED To MATCH EXISTING BATT INSULATION 24" UPPER CABINETS ARCADIA 24" UPPER WALL CABINETS - DOUBLE DOOR OR EQUAL PLYWOOD 5/8" MOISTURE SHEATHING RESISTANT GWB 0 0 30" BASE CABINET ARCADIA 30" BASE CABINET OR EQUAL 36" BASE CABINET ARCADIA 36" BASE CABINET OR EQUAL COUNTERS Uj Z FORMICA COUNTERTOP- FORMICA COLOR: SEA SALT RECEPTION DESK �COUNTERTOP A6 • 1-011 311 1 LIGHTING 2 x 4 LED LIGHT OR EQUAL EXISTING LIGHTS EXISTING RECESSED CAN LIGHTS EXISTING TRACK LIGHTING EXISTING TRACK LIGHTING PORCH LIGHT SUITE PORCH LIGHT; MUST BE SHATTERPROOF OR EQUAL CROWN MOULDING CEILINGS CEILING TILES 12 x 4 ACCOUSTICAL CEILING TILE GYP CEILING FLOORING 3/4" T & G OSB FOR EQUIPMENT PLATFORM OR EQUAL EQUIPMENT PLATFORM 6" 20 GA STRUCT MTL STUD BACK TO BACK 12" OC CT-1 12" CERAMIC TILE OR EQUAL LVP-1 LVP FLOORING OR EQUAL WALLS FAUX BRICK PANELING HOME DEPOT FAUX BRICK PANELING FOR SUITE FINISHES FAUX SHIPLAP PANELING HOME DEPOT FAUX BRICK PANELING FOR SUITE FINISHES PREP ROOM BACKSPLASH FINISH TO BE SELECTED BY OWNER A7 FEATURE WALL AP-1 ACROVYN PANEL ACROVYN ACROVYN 4000 WALL COVERING.04" THICK COLOR 1577 - BLUEBERRY REQUIRED CR-1 CHAIR RAIL 1 3/4" x 8WHITE HARD PRIMED CHAIR RAIL MOULDING MUST BE WHITE OR PAINTED PT-3 OR EQUAL PT-1 PAINT - GREEN SHERWIN WILLIAMS SW6921 ELECTRIC LIME REQUIRED PT-2 PAINT - BLUE SHERWIN WILLIAMS SW6958 DYNAMIC BLUE REQUIRED PT-3 PAINT - WHITE SHERWIN WILLIAMS SW7005 PURE WHITE REQUIRED VB-1 VINYL COVE BASE 4" VINYL COVE BASE MUST BE WHITE OR EQUAL ACCESSORIES �EQUIPMENT PLATFORM LADDER A STOREFRONT ENTRY SEE DETAIL ON A102. DOOR B SUITE DOOR WHITE EXTERIOR FIBERGLASS 2'-8" x 6-8" 9 LITE WITH INTERNAL GRILLE. NO THRESHOLD OR BRICK MOULDING C PASSAGE DOOR WHITE EXTERIOR FIBERGLASS 3'-0" x 6-8" 9 LITE WITH INTERNAL GRILLE. NO THRESHOLD OR BRICK MOULDING D RESTROOM DOOR WHITE EXTERIOR FIBERGLASS 3'-0" x 6-8" NO THRESHOLD OR BRICK MOULDING E CASED OPENING F SALVAGED EXTERIOR EXISTING EXTERIOR DOOR DOOR STOREFRONT SF1 I NEW STOREFRONT SEE ELEVATIONONA120 FOR DETAILS WINDOWS Wl LOBBY WINDOW 1/4" PIL XI GLASS - CASED AND TRIMMED IN FIELD W2 GROOMING WINDOW 1/4" PLEXI GLASS - CASED AND TRIMMED IN FIELD GROOMING TUB OWNER PROVIDED MOP SINK E.L. MUSTEE PREP ROOM SINK KRAUS RESTROOM SINK KOHLER FENCING Fl VESTIBULE FENCING REQUIRED F2 5FENCE PANEL WEATHERABLES PLAYROOM FENCING REQUIRED F3 6' FENCE PANEL WEATHERABLES VINYL FENCE SUITE PARTITION REQUIRED F4 8FENCE PANEL WEATHERABLES OUTDOOR PLAYROOM FENCING REQUIRED Gl VESTIBULE GATE REQUIRED G2 VINYL GATE 3' WIDE VINYL GATE; HEIGHT TO MATCH ADJACENT FENCE HEIGHT REQUIRED MISC 14" x 4" STEEL POST WALLS Al INTERIOR WALL 20 GA 3 5/8" MTL STUD 16" OC W/ 1 LAYER OF 5/8" MOISTURE RESISTANT GWB EACH SIDE. A2 SUITE WALL - 20 GA 3 5/8" MTL STUD 16" OC W/ 1 LAYER OF 1/2" MOISTURE RESISTANT USED ONLY FOR WALLS IN WHICH GWB EACH SIDE. SUITE DOORS ARE INSTALLED A3 INTERIOR KNEE WALL MTL SUD 16" OC W/ 1 LAYER OF 5/8 GWB ON INTERIOR SIDE. WALL TO BE CONSTRUCTED TO 5'AFF 12" AND FINISHED WITH ACROVYN. SEE DETAIL. A4 EQUIPMENT PLATFORM 3 5/8" 20 GA STRUCT MTL STUD 16" OC WITH 5/8" MOISTURE RESISTANT WALLS TO BE CONSTRUCTED TO EQUIP WALL GWB ON EACH SIDE PLATFORM HEIGHT. SEE A102. A4.1 EQUIPMENT PLATFORM 3 5/8" 20 GA STRUCT MTL STUD 16" OC WITH 5/8" MOISTURE RESISTANT WALL GWB ON INTERIOR SIDE. A5 INTERIOR FILL WALL 2 CHANNELS OF 20 GA 2 1/2" MTL STUD 16" OC W/ 1 LAYER OF MOISTURE RESISTANT GWB ON INTERIOR FACING SIDE A6 INTERIOR/EXTERIOR FILL 2 CHANNELS OF 20 GA 2 1/2" MTL STUD 16" OC W/ 1 LAYER OF MOISTURE WALL RESISTANT GWB ON INTERIOR FACING SIDE AND EFIS FINISHED TO MATCH EXISTING EXTERIOR FINISH ON EXTERIOR FACING SIDE EXISTING CMU WALL WIDTH 20 GA 2 1/2" MTL STUD BATT INSULATION 5/8" MOISTURE RESISTANT GWB A5 311 = 1'-0" 18 GA 3 5/8" MTL STUD 3ATT INSULATION 5/8" MOISTURE RESISTANT GWB WALL A4.1 31f 1 1-011• 18 GA 3 5/8" MTL STUD 3ATT INSULATION 3/8" MOISTURE RESISTANT GWB '; 15 20 GA 2 1/2" MTL STUD BATT INSULATION 5/8" MOISTURE RESISTANT GWB EXISTING WALL A3 311 -011 20 GA 3 5/8" MTL STUD 3ATT INSULATION 1/2" MOISTURE RESISTANT GWB A2 311 = 1'-0" ?0 GA 3 5/8" MTL STUD 3ATT INSULATION 5/8" MOISTURE RESISTANT GWB Al 311 -Off C0 co INTERIOR AND EXTERIOR FINISH MAY DIFFER MASONRY CONSTRUCTION MASONRY LINTEL JOINT SEALANT & BACKER ROD. BOTH SIDES HM FRAME W/ ACCOUSTIC INSULATION 0'- 5 3/4" H2 3" -011 JAMB ANCHORS BULLNOSE UNIT JOINT SEALANT & BACKER ROD BOTH SIDES HM FRAME W/ ACOUSTIC INSULATION 0'- 5 3/4" J2 311 1 1-011 DOOR - EXTERIOR OR SOUND DOOR SWEEP U_ U < TI LE A S2 1211 = if -011 0 co LEASH HOOKS LILA" 1 FINISHES TO BE SELECTED BY OWNER FROM OPTIONS PROVIDED AND IN COORDINATION WITH CM AND IN ACCORDANCE WITH 0'- 0 1/161" 0'- 0 1/16" 1/2" SEE PLAN 0 1/2" FRANCHISE 0'- 0 /7 V REQUIREMENTS. INTERIOR PARTITION; SEE FLOOR PLANS • MTL. HEADER FRAMING 1. SEE DETAILS FOR FINISH PAINTABLE SEALANT PLACEMENT FOR ROOMS BOTH SIDES WITH MULTIPLE FINISHES IN N FINISH SCHEDULE. o HM FRAME W/ ACCOUSTIC INSULATION 2. LEASH ROOM, ALL PLAYROOMS, AND ALL O01 - 1 15/16" 0'- 1 15/16" SUITES TO HAVE ACROVYN C> 7 7r PANELS (AP-1) INSTALLED -1wALtTHICKNEss 0 UP TO 50N ALL EXPOSED 4 + 1 1/8" GYP WALLS. PAINT ABOVE AS NOTED ON FINISH PLAN H 1 OR FINISH SCHEDULE. 3"-011 3. RECEPTION TO HAVE CHAIR RAIL INSTALLED 3'AFF. SEE SPEC FOR DIMS. 4. EXISTING BULKHEADS TO BE PAINTED TO MATCH WALL PAINT FOR ROOM. 0'- 0 1/2" SFF PI AN 0'- 0 1/2" - -_ 1. THE EXISTING DEMISING WALL(S) MAY BE RATED INTERIOR PARTION ASSEMBLY - U.L. THIS SEE FLOOR PLAN PARTITION IS REQUIREDTO DOUBLE STUDS FULL PROVIDE A CONTINUOUS HEIGHT OF WALL MIN SEPARATION FROM PAINTABLE SEALANT TENANT SPACE TO ALL N------- BOTH SIDES OD N ADJACENT SPACES. GC TO 22 JAMB ANCHORS VERIFY RATING OF PARTITION ABOVE HM FRAME W/ ACOUSTIC CORRIDOR CEILING AND 0'- 1 15/16" 0'- 1 15/16" INSULATION MAINTAIN RATING AS NECESSARY. WALL THICKNESS 2. PARTITION SUPPORT + 1 1/8" KICKERS ARE NOT TO BE VISIBLE FROM HALLWAYS Ji AND OTHER PUBLIC 311 = 11-011• SPACES. 3. ALL WALLS SHALL EXTEND 6" ABOVE DESIGNATED CEILING HEIGHT UNLESS NOTED OTHERWISE. 4. SUPPORT KICKERS TO STRUCTURE OR TO PERPENDICULAR PARTITION WALL. 5. NO EXPOSED DRYWALL UP DOOR TO 5'IN ANY PLAYROOM INTERIORS. SEE DETAIL BRUSHED ALUMINUM FOR FINISHING SPEC. TRANSITION STRIP 1/4 1/4" 6. ALL CINDERBLOCK WALLS < MAX VERTICAL CHANGE NEW OR EXISTING MUST BE SEALED AND FINISHED. X <1 TILE 7. ALL INT SUITE PARTITIONS TO B IN HE 8. EXT SUITE GYP WALLS NOT TO REACH CEILING TO ALLOW AIRFLOW. SEE DETAIL FOR WALL HEIGHTS. 9. ALL INTERIOR WALLS TO BE WALL TYPE Al UNLESS Si OTHERWISE NOTED. 1211 = 1 1-011 10. ALL WALLS WITH SUITE DOORS INSTALLED SHALL BE WALL TYPE A2. 1 X8" WITH ERASABLE PAINT GYP WALL- ' SEE FINISHPLAN FOR PAINT COLOR ACROVYN PANEL UP TO 5'AFF IN SUI' TYP LEASH HOOK SPACING INTERIORS AND ALL GYP WALLS IN INTE [-- OF PLAYROOMS LEASH ROOM HOOKS DETAIL 1 1/2" = 1'-0" PT-2 SHELF 1X8" ATTACHED TO WALL CONTINUOUS W/ ALL WALLS W/ HOOKS PT-2 CHAIR RAIL PT-1 ON LEASH ROOM WALL DETAIL 1 If = 1 I-Ofl TYP ACROVYN DETAIL 1/2" = 11-011 GYP WALL BEHIND TUB; SEE FINISH SCHEDULE FOR PAINT COLOR 6' BY 6' CERAMIC TILE ON WALLS BEHIND GROOMING TUB. 4" TILE BASE F GROOMING WALL ELEVATION 1/211 = 1 1-011 ffTl 14-H CERAMIC TILE; SEE SPEC LVP; SEE SPEC ACROVYN PANEL; SEE SPEC PT-1- SW6921 ELECTRIC LIME', SATIN PT-2-'SW6958 DYNAMIC BLUE, SATIN PT-3-1 SW7005 PURE WHITE C 0 R I L A N M A P� C h I E 711 N. FIELDER RD. ARLINGTON, TX 76012 PH: (817) 635.5696 FAX: (817) 635.5699 CERTIFIED BY: (?F Fto AR-001i_586 ED A. CORTLAND MORGAN FLORIDA REG. AR - 0015586 DRAWN BY: STAFF r% f 90'*^/0 • WAF 3/17/2022 4.14-07 PM ROOM FINISH SCHEDULE Name Area Wall Finish Base Finish RECEPTION 383 SF PT-1, PT-2, CR-1 VB-1 LEASH 35 SF PT-2, AP-1 CT-1 GROOMING 115 SF PT-2, CT-1 CT-1 PREP ROOM 110 SF PT-3 VB-1 RESTROOM 47 SF PT-3 I CT-1 OFFICE 91 SF PT-3 VB-1 STORAGE 91 SF PT-3 VB-1 PLAYROOM <varies> AP-1; PT-1, PT-2 CT-1 STD <varies> PT-2, AP-1 CT-1 LUX <varies> PT-2, AP-1 CT-1 DBL <varies> PT-2, AP-1 CT-1 OUTDOOR PLAYROOM 720 SF VERIFY ALL DIMENSIONS, SQFT, AND COUNTS IN FIELD OR BEFORE INSTALL. 1. BANYAN CS FLOORING SCOPE NEEDS TO BE SIGNED BEFORE ANY WORK BEGINS. 2. REFER TO BUDGET. IF YOU HAVE EXCESSIVE FLOOR, SEND UP RED FLAG. 3. FLOOR PREP AND GENERAL SWEEP TO BE COMPLETED BEFORE INSTALL. 4. NO SWEEPING DURING INSTALL - VACUUM ONLY. 5. FLOORING MUST RUN UNDER ALL CABINETS. 6. GROUT MUST BE WIPED OFF IMMEDIATELY AFTER APPLYING. 7. FLOOR CLEANOUTS & FLOOR DRAINS MUST BE LEVEL. DO NOT GROUT UNTIL LEVEL. 8. ALL CERAMIC TILE MUST BE SEALED PRESSED TILE IN A NEUTRAL, LIGHT COLOR AND WITH LIGHT COLORED GROUT. 9. LVP NOT TO BE USED IN ANY AREA DESIGNATED FOR ANIMALS (IE PLAYROOMS, SUITES, GROOMING, LEASH). LUX SUITE TYP STD SUITE TYP 1. PORCH LIGHTS ON SUITES 3/4" = 1'-011 3/4" = 1'-011 TO BE INSTALLED ON CENTER BETWEEN DOOR FRAMES. 2. ALL PLAYROOM FENCING TO BE 5' HIGH UNLESS NOTED OTHERWISE. 3. ALL PLAYROOM FENCE GATES TO BE T MIN WIDTH AND MATCH ADJACENT FENCE HEIGHT. 4. ALL PLAYROOM GATES TO HAVE SELF -CLOSING HINGES. 5. BASE OF PLAYROOM FENCE RAIL TO BE MAX 1" AFF. 5'-9" 0'-5" 4'-0" 0'-11/2" 4'-0" 0'-11/2" 4'-0" 0'-11/2" 4'-0" 0'-11/2" 4'-0" 0'-11/2" 4'-0" 0'-11/2" 4'-0" 0'-11/2" 4'-0" 0'-11/2" 4'-0" 0'-5" 4'-83/4" 0'-5" 8'-4" FINISH PLAN 1 /411 = 1'-011 1. SEE DETAILS FOR FINISH PLACEMENT FOR ROOMS WITH MULTIPLE FINISHES IN FINISH SCHEDULE. 2. LEASH ROOM, ALL PLAYROOMS, AND ALL SUITES TO HAVE ACROVYN PANELS (AP-1) INSTALLED UP TO 5' ON ALL EXPOSED GYP WALLS. PAINT ABOVE AS NOTED ON FINISH PLAN OR FINISH SCHEDULE. 3. RECEPTION TO HAVE CHAIR RAIL INSTALLED T AFF. SEE SPEC FOR DIMS. 4. EXISTING BULKHEADS TO BE PAINTED TO MATCH WALL PAINT FOR ROOM. CERAMIC TILE; SEE SPEC LVP; SEE SPEC ACROVYN PANEL; SEE SPEC PT-1; SW6921 ELECTRIC LIME, SATIN PT-2; SW6958 DYNAMIC BLUE, SATIN SW7005 PURE ❑PT-3; WHITE C O R I L A NI D MI O R G A N ARC H I I E C 711 N. FIELDER RD. li ARLINGTON, TX 76012' PH: (817) 635.5696 FAX: (817) 635.5699 CERTIFIED BY: q F- F` o,� o�_,��PNo MORc , E® A CORTLAND MORGAN FLORIDA REG. AR - 0015586 D RAW N BY: STAFF 90% 6440 FORT KING ZEPHYRHILLS, FL 33542 DARREN & LUANN ■ Owner CONSTRUCTION JANSEN GEHRING 317.747.0555 ZEPHYR HILLS FINISH PLAN A121 3/17/2022 4:14:09 PM _ - — � I Ilr. ., �L,. t��dl . r6�� ., ,WLn111GKJ1.ulllfde4 a. iiYIW tl.111 1.419YI�IIlYL111YYY IAN i� I. ..�. ... _:, _.:I. ... ��� �:. ., �, 1. A...:. L_.li I,i-..__�.. c� ..� � � � _.. .. .. ._ - ... .- .:.::.I ._..._ �� d. _,i. r3 L � II �w-f.,,_. &IJ�L.< _ Ln,,,..,� ar �k_L Nl➢,dl . i .t.. � � ,! WALL BRACKET HOLD TOP P BOTTOM R FENCE PARTITION DETAIL 3/4" = 1'-0" 5"x5" PYRAMID POST CAP —�� 5"x5" PYRAMID POST CAP �- U U FENCE POST SUNK 2' u- u- FENCE POST SUNK 2' zo zo 0 0 ALUMINUM GATE POST O O INSERT SUNK 2' a � bo 6) BOTTOM OF RAIL 1"AFF. BOTTOM OF RAIL 1"AFF. � - - CONCRETE MIX FILL CONCRETE MIX FILL 8" CORE DRILLED HOLE a b 8" CORE DRILLED HOLE o FENCE POST DETAIL TYP 3/4" = 1'-0" w w w w u- u- i zo u- u- a a QQ co6�' FENCE GATE POST DETAIL TYP 3/4" = 1'-0" R. -n„ 7'-n" 7'-0„ FENCE LAYOUT 1 /4" = 1'-0" 1. ALL PLAYROOM FENCING TO BE 5' HIGH UNLESS OTHERWISE NOTED. 2. ALL PLAYROOM FENCE GATES TO BE T MIN WIDTH AND MATCH ADJACENT FENCE HEIGHT. 3. FENCE TO BE INSTALLED WITH BOTTOM RAIL NO MORE THAN 1" AFF. SEE DETAIL. 4. WHERE FENCE MEETS WALLS, WALL BRACKETS TO BE USED INSTEAD OF POSTS. SEE DETAIL. 5. ALL POSTS AT GATE HINGE SIDE TO HAVE ALUMINUM POST INSERT INSTALLED FOR REINFORCEMENT. SEE DETAIL. C 0 R I L A Ni D [ O R G A N ARC H I I H C 711 N. FIELDER RD. ARLI NGTON, TX 76012 PH: (817) 635.5696 FAX: (817) 635.5699 CERTIFIED BY: �E ® -Fta� y o¢�LPND M0�,C� ..V —*— f A R-0411558 ' SrFfi'ED AR�� CORTLAND MORGAN FLORIDA REG. AR - 0015586 DRAWN BY: STAFF 90% f 6440 FORT KING ZEPHYRHILLS, FL 33542 DARREN & LUANN Owner BANYAN CONSTRUCTION JANSEN GEHRING 317.747.0555 ZEPHYR HILLS FENCE PLAN AND DETAILS A122 3/17/2022 4:14:10 PM SUITE 16 3/8" = 1'-0" SUITE 32 3/8" = 1'-0" SUITES 9-15 3/8" = 1'-0" SUITES 27-31 3/8" = 1'-0" • LOBBY ELEVATION 1 /2" = 1'-0" vv INTERIOR DESK WALLv v , SUITES 5-8 3/8" = 1'-0" FEATURE WALL ELEVATION • 1 /2" = 1'-0" BACKSPLASH SUITES 1-4 N 3/8" = 1'-0" SUITES 17-26 3/8" = 1'-0" CASEWORK ELEVATION 1 /2" = 1'-0" NO N ADA COUNTER COUNTERTOP SITTING ON WALL BELOW. 3 5/8" MTL STUDS @ 16" OC W/ 1 LAYER zc OF 5/8" GYP BOTH SIDES. -------------- L------------------------ L--------------------------------------J T-0" 5'-0" RECEPTION DESK DETAIL 3/411 = 11-011 1. SEE DETAILS FOR FINISH PLACEMENT FOR ROOMS WITH MULTIPLE FINISHES IN FINISH SCHEDULE. 2. LEASH ROOM, ALL PLAYROOMS, AND ALL SUITES TO HAVE ACROVYN PANELS (AP-1) INSTALLED UP TO 5' ON ALL EXPOSED GYP WALLS. PAINT ABOVE AS NOTED ON FINISH PLAN OR FINISH SCHEDULE. 3. RECEPTION TO HAVE CHAIR RAIL INSTALLED 3' AFF. SEE SPEC FOR DIMS. 4. EXISTING BULKHEADS TO BE PAINTED TO MATCH iiiiiiiiiiiiiiiiiiiiiiiiiiii�WALL PAINT FOR ROOM. 1. PORCH LIGHTS ON SUITES TO BE INSTALLED ON CENTER BETWEEN DOOR FRAMES. 2. ALL PLAYROOM FENCING TO BE 5' HIGH UNLESS NOTED OTHERWISE. 3. ALL PLAYROOM FENCE GATES TO BE 3' MIN WIDTH AND MATCH ADJACENT FENCE HEIGHT. 4. ALL PLAYROOM GATES TO HAVE SELF -CLOSING HINGES. 5. BASE OF PLAYROOM FENCE RAIL TO BE MAX 1" AFF. 1. ALL NEW INTERIOR DOORS TO BE LEVER TYPE DOOR HANDLE WITH EXCEPTION OF THE 'SUITES'. THESE ARE PUSH/PULL. 2. ALL DOORS PROVIDE 32" CLEAR WIDTH IN THE FULLY OPENED POSITION AND ARE READILY OPENABLE FROM EGRESS SIDE WITHOUT KEY, SPECIAL KNOWLEDGE OR EFFORT. 3. ALL HARDWARE FINISHES TO BE BRUSHED SATIN NICKEL FINISH UNLESS OTHERWISE NOTED. 4. ALL EGRESS DOORS (NEW OR EXISTING) LEADING TO THE EXTERIOR OF THE BUILDING ARE TO HAVE SIGNS ON THEM STATING THIS DOOR TO REMAIN UNLOCKED DURING BUSINESS HOURS". 5. VERIFY THAT ALL LOCK KEYED CYLINDER(S) SHALL BE OF THE TYPE THAT ACCEPTS INDUSTRY STANDARD "SMALL FORMAT INTERCHANGEABLE CORES" (E.G. FALCON, ARROW, BEST, ETC). CONTRACTOR SHALL INSTALL SAID LOCKS WITH CONTRACTOR'S OWN CORES AND QUANTITY OF KEYS REQUIRED FOR CONTRACTOR PURPOSES DURING CONSTRUCTION. 6. ALL INTERIOR DOORS TO HAVE THRESHOLDS REMOVED BEFORE INSTALL. 7. ALL STANDARD SUITE DOORS TO BE CENTERED ON SUITE SPACE. 8. PASSAGE DOORS TO USE S1 WHERE TILE FLOOR IS UNINTERRUPTED BETWEEN SPACES. S2 TO BE USED WHERE LVP TRANSITIONS TO TILE FLOORING. CERAMIC TILE; SEE SPEC LVP; SEE SPEC ACROVYN PANEL; SEE SPEC PT-1; SW6921 ELECTRIC LIME, SATIN PT-2; SW6958 DYNAMIC BLUE, SATIN [_7 PT-3; SW7005 PURE WHITE C 0 R I L A ICI D m 0 P� G A ICI APLC H IEC 711 N. FIELDER RD. ARLINGTON, TX 76012 P H : (817) 635.5696 FAX: (817) 635.5699 CERTIFIED BY: co oRc\,pND Ilio, C, 9 A R-001558 �. ti ED ARG� CORTLAND MORGAN FLORIDA REG. AR - 0015586 D RAW N BY: STAFF 90% TOWN 6440 FORT KING ZEPHYRH I LLS, FL 33542 DARREN & LUANN Owner CONSTRUCTION JANSEN GEHRING 317.747.0555 ZEPHYR HILLS WALL ELEVATIONS & DESK DETAIL 3/17/2022 4.14.13 PM 1. EXISTING CEILING TO REMAIN WITH NEW DROP CEILING TO BE INSTALLED BELOW IN ROOMS INDICATED ON PLANS. PATCH AND REPAIR EXISTING CEILING AS REQUIRED FOR REMOVAL OF EXISTING LIGHTS AND INSTALL OF NEW LIGHTING. 2 x 4 ACOUSTICAL CEILING TILE 2 x 4 LIGHT FIXTURE SEE SCHEDULE ® 8' LED STRIP LIGHT ❑ NEW CONSTRUCTION EXST CONSTRUCTION NEW DOOR AND FRAME TO BE INSTALLED C-- - C O R I L A ARC H I F C 711 N. FIELDER RD. ARLINGTON, TX 76012' PH: (817) 635.5696 FAX. (817) 635.5699 CERTIFIED BY: OF Mo 'U AR-0015586 '4 QED A� CORTLAND MORGAN FLORIDA REG. AR - 0015586 D RAW N BY: STAFF 90% 6440 FORT KING ZEPHYRHILLS, FL 33542 DARREN & LUANN Owner CONSTRUCTION JANSEN GEHRING 317.747.0555 ZEPHYR HILLS REFLECTED CEILING PLAN REFLECTED CEILING PLAN 1 /4" = 1'-0" EXST DOOR AND FRAME PORCH LIGHT 3/17/2022 4:14:14 PM ELECTRICAL EQUIPMENT SPECIFICATIONS PANELS: SQUARE D TYPE NQODCU RECESSED MOUNTED COPPE BUS, BOLTED CIRCUIT BREAKER PANELBOARD, 120/208 VOLT, 3PH., 4 WIRE OR EQUIVALENT. TIME CLOCK: COORDINATE WITH ELECTRICAL CONTRACTOR DUPLEX RECEPTACLES: HUBBELL #5262-WHI. UNLESS OTHERWISE NOTED. DUPLEX RECEPTACLES: HUBBELL #5262-BL. UNLESS OTHERWISE NOTED. QUAD RECEPTACLE: TWO (2) HUBBELL #5262-WHI DUPLEX RECEPTACLES IN COMMON JUNCTION BOX WITH 4 GANG COVER PLATE UNLESS OTHERWISE NOTED. ISOLATED GROUND RECEPTACLES: HUBBELL #IG-5262-WHI UNLESS OTHERWISE NOTED. ISOLATED GROUND QUAD RECEPTACLES: TWO (2) HUBBELL MG-5262-WHI DUPLEX RECEPTACLES IN COMMON JUNCTION BOX WITH 4 GANG COVER PLATE UNLESS OTHERWISE NOTED. GROUND FAULT RECEPTACLE: HUBBELL #GF-5252-WA UNLESS OTHERWISE NOTED. SINGLE POLE SWITCHES: HUBBELL #HBL-1221-WHI. ELECTRICAL NOTES REMOVE ALL EXISTING LIGHTING FIXTURES, SWITCHES, JUNCTION BOXES, CONDUIT, WIRING, ETC., NOT REQUIRED FOR REUSE. THE EXISTING 200 AMP 120/208 VOLT 3 PHASE SERVICE SHALL BE REUSED. ELECTRICAL CONTRACTOR SHALL EXTEND THE EXISTING SERVICE TO THE NEW PANEL LOCATION. BASE BID SHALL INCLUDE ANY ADDITIONAL CONDUIT AND WIRING AND CONNECTIONS OF THE ELECTRICAL EQUIPMENT, ETC. THE EXISTING SERVICE DISTRIBUTION EQUIPMENT INCLUDING THE METER AND THE 200 AMP MAIN DISCONNECT SWITCH SHALL REMAIN AND BE REUSED. VERIFY AND CHANGE AS REQUIRED TO ADEQUATELY PROTECT THE FEEDER TO THE SPACE. IF ANY ISSUES ARISE WITH REGARD TO REUSE OF SERVICE AND EQUIPMENT, CONTACT ARCHITECT AND/OR ENGINEER PRIOR TO BID FOR DISPOSITION. THE ELECTRICAL CONTRACTOR SHALL FIELD VERIFY AND VIEW ALL EXISTING CONDITIONS BEFORE SUBMITTING A PROPOSAL FOR THE WORK AS DESCRIBED AND SHOWN. EXTRAS WILL NOT BE PERMITTED FOR FAILURE TO MAKE THIS VISIT. THE INTENT OF THE WORK WITH REGARD TO ELECTRICAL DISTRIBUTION AS INDICATED ON THE DRAWINGS IS AS FOLLOWS: A. ALL EXISTING ELECTRICAL EQUIPMENT NOT CURRENTLY BEING USED TO FEED ANYTHING AND NOT REQUIRED AS PART OF THIS REMODEL SHALL BE REMOVED. B. EXISTING ELECTRICAL EQUIPMENT CURRENTLY BEING USED TO FEED LIGHTING, EQUIPMENT, ETC, SHALL BE REUSED. A DETAILED FIELD INSPECTION OF THE EXISTING EQUIPMENT SHALL BE INCLUDED IN THE BASE BID TO DETERMINE ITS CONDITION AND COSTS TO PERFORM MAINTENANCE SERVICE. INSPECTION SHALL INCLUDE THE FOLLOWING: 1. CHECK ENTIRE INSTALLATION FOR CODE COMPLIANT CLEARANCES. MODIFY INSTALLATION AND EQUIPMENT LOCATION AS REQUIRED. 2. CHECK CONDUITS FOR PROPER INSTALLATION, I.E. TIGHT CONNECTIONS, PROPER FITTINGS, RUSTING, CREASING, BENDING, ETC. REPAIR OR REPLACE AS REQUIRED. 3. CHECK FOR BARE WIRING. COVER OR REPLACE AS REQUIRED. 4. CHECK FOR PROPER GROUNDING OF SYSTEM AND EQUIPMENT. CORRECT AS REQUIRED. 5. CHECK FOR CIRCUIT OVERLOADING AND/OR TRIPPING. REPLACE BREAKERS AND/OR FUSES AS REQUIRED. REDISTRIBUTE CIRCUITING OF EQUIPMENT AND/OR LIGHTING AS REQUIRED. 6. REPAIR ANY RUSTED AREAS ON EQUIPMENT CASINGS. REPAINT AS REQUIRED. 7. VERIFY THE SIZES OF THE EQUIPMENT IN FIELD AS SHOWN AND CALLED FOR - IF EQUIPMENT IS NOT SIZED AS REQUIRED, CONTACT THE ARCHITECT/ENGINEER. AN ALTERNATE PROPOSAL SHALL BE SUBMITTED TO REPLACE ANY AND/OR ALL EXISTING EQUIPMENT, IF THE EQUIPMENT IS DETERMINED TO BE IN NEED OF REPLACEMENT AFTER THE INSPECTION AT THE JOB SITE. ALTERNATE PROPOSAL SHALL BE COMPLETE. FURNISH AND INSTALL NEW ELECTRICAL PANELS AS REQUIRED. FURNISH AND INSTALL TYPEWRITTEN PANEL DIRECTORIES AS SHOWN. CIRCUITS SHALL BE CONNECTED TO THE PANELS AND ARRANGED TO COMPLY WITH THE NUMBERS SHOWN ON THE DRAWINGS. UNUSED CIRCUITS SHALL BE UTILIZED AS SPARES. PROVIDE ADEQUATE TEMPORARY POWER AND LIGHTING. MAINTAIN ALL REQUIRED CLEARANCES AT ALL ELECTRICAL EQUIPMENT AND COMPLY WITH N.E.C. ARTICLE 110. TIME CLOCK AND OTHER MISCELLANEOUS ELECTRICAL COMPONENTS SHALL NOT BE INSTALLED ON THE TELEPHONE TERMINAL BOARD. FURNISH AND INSTALL NEW FIRE ALARM SYSTEM (IF REQUIRED). COORDINATE WITH LANDLORD. TEMPERATURE CONTROL EXCLUDED FROM ELECTRICAL CONTRACT. CONTRACTOR SHALL NOTIFY THE ARCHITECT AND/OR ENGINEER OF ERRORS, OMISSIONS OR DISCREPANCIES BEFORE CONSTRUCTION OR FABRICATION OF AFFECTED WORK, OR, FAILING SUCH NOTICE, SHALL BE RESPONSIBLE FOR CORRECTING SAME WITHOUT COST TO TENANT, ARCHITECT OR ENGINEER. WORK SHALL INCLUDE START UP OF ALL SYSTEMS. PROVIDE ONE YEAR LABOR WARRANTY ON ENTIRE INSTALLATION AND ONE YEAR PARTS WARRANTY ON ALL EQUIPMENT SUPPLIED BY SUB -CONTRACTOR. FURNISH ALL MANUALS, MAINTENANCE INSTRUCTIONS, AND WARRANTIES TO CONTRACTOR. MOUNT SWITCHES 4'-0" ABOVE FLOOR UNLESS OTHERWISE NOTED. ALL CONDUITS FOR USE BY OTHERS SHALL BE CONTINUOUS, CONTAIN PULL STRINGS, AND HAVE PULL BOXES AS NECESSARY. ALL RECEPTACLE LOADS ARE BASED ON 180 WATTS FOR DUPLEX DEVICES AND 360 WATTS FOR QUAD DEVICES. ALL PANEL LOCK DEVICES MUST BE U.L. LABELED -LISTED. ALL ELECTRICAL EQUIPMENT AND MATERIAL SHALL BE SUITABLE FOR INSTALLATION AND USE IN CONFORMITY WITH NEC 110.3(A)(1). SEAL AROUND ALL ELECTRICAL PENETRATIONS OF FIRE RATED WALLS PER NEC 300.21. PANEL EXISTING P1 LUGS 225 AMP 120/208 VOLT 3 PHASE 4 WIRE AIC RATING:22,000 MAIN BREAKER 200 AMP ORTIZ-3mgm m EX COND #1 �■■�omm �■■ COND #3 In Ron no a 11100 11100 ` ® ®' so�M® ME n EQUIP RECPT 11100 Wes■■�■■�on�n - • - 11100 ` m_■■�■■�®_®®' 11100 PANEL P2_ FEED- 11100 ® ■■ ®0 � _ 1 ' ®IMME■■�■■�■■MO ' 11100 11100 _ ` MISSES ■�■■�■■MO _ A. 11100 _ ` ®_■■�■■�■■_® ` 11100 ®INNI■■�■■�■■IMMEm ' 11100 • • ®_■■�■■�■■_ ® • _ 11100 � ®�■■�■■�■■MO � 11100 .:. OMEN ■■ m . _ . 11100 "*" INDICATES PANEL LOCKS PHASE A: 26912 WATTS PHASE B: 26424 WATTS PHASE C: 25980 WATTS TOTAL 79316 WATTS BALANCE 3.46% CONNECTED 79,316 W. 220.3 A. PANEL EXISTING P2 LUGS 100 AMP 120/208 VOLT 3 PHASE 4 WIRE AIC RATING:22,000 MAIN BREAKER 100 AMP WIRE SIZE USE CKT. NO. LOAD KVA BKR SIZE A B C BKR SIZE LOAD KVA CKT. NO. USE WIRE SIZE SPARE 1 20/1 20/1 2 SPARE SPARE 3 4 SPARE SPARE 5 250 6 SIGN LIGHTING 7 432 1080 8 LOBBY RECPT LIGHTING 9 174 360 10 RECEPTION RECPT LIGHTING 11 350 360 12 GROOMING GFCI LIGHTING 13 650 180 14 GROOMING RECPT LIGHTING 15 312 180 16 1 GROOMING RECPT LIGHTING 17 342 180 18 GEN RECPT SPARE 19 720 20 OFFICE RECPT SPARE 21 1080 22 STOCKROOM FGCI SPARE 23 1080 24 1 KENNEL RECPT SPARE 25 900 26 1 KENNEL RECPT SPARE 27 28 SPARE SPARE 29 180 30 RESTROOM GFCI SPARE 31 32 SPARE SPARE 33 34 SPARE SPARE 35 36 SPARE SPARE 37 180 38 WASHER SPARE 39 30/2 2250 40 DRYER SPARE 41 L _F2250 42 "*" INDICATES PANEL LOCKS PHASE A: 4142 WATTS PHASE B: 4356 WATTS PHASE C: 4992 WATTS TOTAL 13490 WATTS BALANCE 17.03% CONNECTED 67,332 W. 187.0 A. EXISTINGDISC SW #1 60/50, NEMA 3R EXISTING COND #1 ON GROUND P1-16 WR 20A. GFCI RECEPTACLE - IN WEATHER RESISTANT BOX 3-#6 CU, 1 #8 GRD. 1 "C. NEW DISC SW #2 60/50, NEMA 3R I I \ NEW COND #1 ON GROUND P1-16 WR 20A. GFCI RECEPTACLE - IN WEATHER RESISTANT BOX 3-#6 CU, 1 #8 GRD. 1 "C. NEW DISC SW #3 30/30, NEMA 3R NEW COND #2 ON GROUND WR 20A. GFCI RECEPTACLE - IN WEATHER RESISTANT BOX EXISTING DISC SW #4 100/70, NEMA 1 P1-16 3-#4 CU, 1 #8 GRD. 1-1 /4"C. EXISTING AHU #1 SUSPENDED WR 20A. GFCI RECEPTACLE IN WEATHER RESISTANT BOX NEW DISC SW #5 100/70, NEMA 1 P1-16 3-#4 CU, 1 #8 GRD. 1-1 /4"C. NEW AHU #2 SUSPENDED WR 20A. GFCI RECEPTACLE IN WEATHER RESISTANT BOX NEW DISC SW #6 100/70, NEMA 1 P1-16 11 11 P1-16 3-#6 CU, 1 #8 GRD. 1 "C. I I I-- 3-#4 CU, 1 #8 GRD. 1-1 /4"C. EXTERIOR OF BUILDING I HOUNDSTOWN FIRST FLOOR 4-#3/0 CU, 11 #4 GRD., 2"C. EXISTING TO REMAIN 4-#3/0 CU, 1 #4 GRD., 2"C. EXISTING 200 AMP DISCONNECT SWITCH WITH 200 AMP FUSES CONNECT TO EXISTING O ' R EXISTING 225 AMP 120/208V. EXISTING 100 AMP 120/208V. 200A. PNL "P1" PNL "P2" 200 AMP 100 AMP BREAKER BREAKER RELOCATED RELOCATED EXISTING METER SOCKET TO REMAIN NEW METER BY E.C. 4-#3 CU, 1 #4 GRD., 1-1 /4"C. RISER DIAGRAM NOTES 1. OBTAIN AVAILABLE FAULT CURRENT RATING AND PROVIDE PROTECTION FOR MAIN CIRCUIT BREAKER AND ALL BRANCH DEVICES. 2. MAINTAIN ALL REQUIRED CLEARANCES PER ARTICLE 110-26 NEC POWER RISER DIAGRAM. NOT TO SCALE NEW AHU #3 SUSPENDED WR 20A. GFCI RECEPTACLE IN WEATHER RESISTANT BOX 2 O _ N � � � � Z W uj U w m NW%.:j Z I z �o Wo ON ¢ o o 0)co tTm�:QO o� L2LZ mal CERTIFIED BY: 6440 FORT KING ZEPHYRHILLS, FL 33542 DARREN & LUANN Owner LJANSEN GEHRING 317.747.0555 ZEPHYR HILLS ELECTRICAL SPECIFICATIONS E101 GENERAL NOTES: AorC C 346-1" TO KTS. P1-2,4,4 A.C.UNIT #3 346-1" TO CKTS.P1-10,12 1. ALL CIRCUITS ON THIS SHEET TO EXISTING PANEL P2 UNLESS NOTED OTHERWISE. 2. REFER TO ARCHITECTURAL FOR ADDITIONAL NOTES AND MOUNTING HEIGHTS. PLAN NOTES: O1 EXISTING 200 AMP 120/208 VOLT PANEL P1 RELOCATED. O2 EXISTING 100 AMP 120/208 VOLT PANEL P2 RELOCATED. O3 COORDINATE MOUNTING HEIGHT AND LOCATION WITH OWNER. ELECTRICAL LEGEND A DUPLEX - 120V- 15-20 AMP SHALL BE 18" AFF . ELECTRICAL NOTES 1. ALL WORK SHALL CONFORM TO APPLICABLE FEDERAL, STATE AND LOCAL CODES. 2. ALL NEW OR EXISTING RECESSED ELECTRICAL PANELS TO HAVE FLUSH COVERS. 3. THE CONTRACTOR SHALL OBTAIN ALL NECESSARY PERMITS AND SHALL PAY ALL REQUIRED FEES FOR THIS WORK. 4. THE CONTRACTOR SHALL FIELD VERIFY EXISTING CONDITIONS AND REPORT TO BANYAN CONSTRUCTION IN WRITING / TELEPHONE: 317-698-1001, ANY DISCREPANCIES IMMEDIATELY UPON DISCOVERY. 5. UNLESS OTHERWISE NOTED, ALL TELEPHONE, ELECTRICAL, CABLE & DATA LINE OUTLETS SHALL BE LOCATED 18" ABOVE THE FINISHED FLOOR. 6. UNLESS OTHERWISE NOTED, DIMENSIONS FOR ALL NEW WORK ARE MEASURED FROM FACE OF GYPSUM BOARD. DIMENSIONS REFERRING TO EXISTING WORK ARE MEASURED FROM FACE OF EXISTING FINISH. 7. $ SWITCH GROUP REQUIRES 8" OF WALL SPACE. SHIFT AS NEEDED. 8. BACK TO BACK PLUGS WILL NOT WORK IN A 3 5/8" STUD WALL. SHIFT AS NEEDED. CABINET PLUG LOCATIONS ARE CRITICAL AND SHOULD NOT BE MOVED. 9. ADD DEEPER MUD RINGS ON WALLS WITH DOUBLE DRYWALL. 10. ALL ELECTRICAL DIMENSIONS ARE TO CENTER -LINE. ALL'HOLD' DIMENSIONS ARE CRITICAL. 2 O C) U N N 0 Z >d co 00Z m '` N W Ic z Z -2 `n c r to 00 w= WW Z zCD W d' 0 Q r oLo O O LL. Z CERTIFIED BY: 91:4m"Myj01on ,f STAFF 6440 FORT KING ZEPHYRHILLS, FL 33542 DARREN & LUANN Owner JANSEN GEHRING 317.747.0555 ZEPHYR HILLS FLOOR PLAN 102 GENERAL NOTES: 1. ALL CIRCUITS ON THIS SHEET TO EXISTING PANEL P2 UNLESS NOTED OTHERWISE. I 2. REFER TO ARCHITECTURAL SHEET A150 FOR ADDITIONAL NOTES AND MOUNTING HEIGHTS. I I PLAN NOTES: 0- CEILING PLAN LEGEND VERIFY ALL SELECTIONS WITH STORE OWNER SYMBOL DESCRIPTION O EXISTING TO REMAIN ® METALUX #24FP4740C, 41.4 WATT RECESSED LIGHT PORTFOLIO LIGHTING MODEL #40683, 26 WATT, 8.25-IN H BLACK WALL LIGHT LIGHT SWITCH Q CEILING MOUNTED OCCUPANCY SENSOR oc AMAX LIGHTING MODEL #LED-SL27BZ, 27 WATT, DUST TO DAWN, BRONZE X1e DUAL HEAD EXIT LIGHT AND STANDARD EXIT LIGHT (AS REQUIRED BY CODE). EXIT SIGNS SHALL HAVE BATTERY BACKUP. DUAL HEAD LED EMERGENCY PACK WITH BATTERY BACK-UP. DUAL-LITE EV2 SERIES OR EQUIVALENT. CEILING MOUNTED. DUAL HEAD LED EMERGENCY PACK WITH 120 MINUTE BATTERY BACK-UP. X3 INDUSTRIAL EMERGENCY LIGHTING #ESW-LEDSDXR627 OR EQUIVALENT. LIGHTING NOTES 1. ALL WORK TO STRICTLY COMPLY WITH ALL FEDERAL, STATE & LOCAL CODES. 2. ALL LIGHTING TO BE VERIFIED WITH OWNER. 3. LOCATIONS & QUANTITIES OF CAN LIGHTS & SCONCES TO BE VERIFIED WITH OWNER. 4. CEILING TILES MUST BE APPROVED BY OWNER. 5. ALL CEILING HEIGHTS TO BE VERIFIED WITH OWNER. 6. G.C. TO PROVIDE EXIT SIGNS, FIRE EXTINGUISHERS, EMERGENCY LIGHTS, ETC. AS REQUIRED BY LOCAL CODES. 7. ALL EMERGENCY AND EXIT LIGHTS SHALL BE BUILDING STANDARDS AND APPROVED BY OWNER. 8. ELECT. TO VERIFY ALL LOCATIONS OF SCONCES AFTER BOXES HAVE BEEN INSTALLED BUT BEFORE THE WIRING HAS BEEN PULLED IN CASE CHANGES ARE WANTED. N O W Z Z �_ m as ^ a 0 co c I Z wco o O� Y O D Q� r d- 0 r � Fn O Z I � I QU I I ,CERTIFIED BY: i i i :2 '*4C, COO ZaZ:co * W .W a a 0 =� :V O � :O•.� Z N 4 I I I I I D RAW N BY. - STAFF 6440 FORT KING ZEPHYRHILLS, FL 33542 DARREN & LUANN Owner ZEPHYR HILLS ELECTRICAL LIGHTING PLAN 103 A.C.UNIT #1 A.C.UNIT #2 A.C.UNIT #3 7 � WALL THIMBLE WITH BUILT—IN HOOD TERMINATION DRYER EXHAUST 1. DRYER VENTING SHALL COMPLY WITH 2O15 MECHANICAL CODE. MAXIMUM LENGTH OF DUCT INCLUDING SHALL BE 4 FEET. 2. DUCTS SHALL NOT BE JOINED WITH SCREWS OR SIMILAR FASTENERS THAT PROTRUDE INTO THE INSIDE OF THE DUCT. 3. TRANSITION DUCTS USED TO CONNECT THE DRYER TO THE EXHAUST DUCT SYSTEM SHALL BE A SINGLE LENGTH THAT IS LISTED AND LABELED IN ACCORDANCE WITH UL 2158A. JOIST CLAMP (TYPICAL FOR 4) DRYER VENT DETAIL TREADED ROD NOT TO SCALE YPICAL FOR 4) RATION ISOLATOR PICAL FOR 4) -STRUT ICAL) A.C. SUSrLNULU ALL SUPPORT COMPONENTS SHALL BE SIZED AS REQUIRED TO ADEQUATELY ACCOMMODATE SUSPENSION OF UNIT —CONTACT ARCHITECT OR STRUCTURAL ENGINEER FOR MORE INFORMATION. AHU SUPPORT DETAIL. NOT TO ac•L VOLUME DAMPER LOCATED ACCESSIBLE LOCATION. PR ACCESS DOOR OR CABLE OPERATOR IF NOT ACCESSIE REFLECTIVE TAPE SHALL BE USED. INSUU BACK VAPOR ...., ..," — —... , . CLAMP (TYPICAL) 'LEXIBLE DUCT ) MORE THAN VD) -ITTING AS REQ'D DIFFUSER BLADE DAMPER ACTUATOR (RADIAL BLADE DAMPER ACTUATOR SHALL BE INSTALLED ON ALL SUPPLY DIFFUSERS.) DIFFUSER DETAIL. WT TO WAX 10'-0" MIN. IL E 1 1 1 PLAN NOTES: 0 EXISTING AHU #1 SUSPENDED TO REMAIN. BALANCE SUPPLY AIR TO 2000 CFM AND OUTSIDE AIR TO 375 CFM. 0 NEW AHU #2 SUSPENDED. BALANCE SUPPLY AIR TO 2000 CFM AND OUTSIDE AIR TO 1200 CFM. 0 NEW AHU #3 SUSPENDED. BALANCE SUPPLY AIR TO 1200 CFM AND OUTSIDE AIR TO 200 CFM. O4 NOT USED. O5 3/4" CONDENSATE DRAIN TO REMAIN. CONTRACTOR SHALL VERIFY PROPER TERMINATION IN FIELD. 0 NEW TOILET EXHUAST FAN. EXHAUST DUCT SHALL CONNECT TO EXISTING. VERIFY EXISTING CONNECTION POINT IN FIELD. 07 EXISTING CONDENSING UNIT #1 ON GROUND SHALL BE REUSED. 0 NEW CONDENSING UNIT #2 ON GROUND. 0 NEW CONDENSING UNIT #3 ON GROUND. 10 NOT USED. 11 LIQUID AND SUCTION LINE TO AIR HANDLING UNITS AS REQUIRED. CONTRACTOR SHALL CHECK FOR LEAKS. 12 4" DRYER VENTS SHALL TERMINATE TROUGH EXTERIOR WALL WITH APPROVED VENT CAP. SEE DETAIL. VENT SHALL BE 10'-0" AWAY FROM ANY INTAKE. FURNISH AND INSTALL BOOSTER FAN IF EXHAUST DUCT IS OVER 30'-0". 13 EXISTING THERMOSTAT —RELOCATED. VERIFY EXACT LOCATION WITH OWNER. 14 MECHANICAL CONTRACTOR SHALL FURNISH AND INSTALL VOLUME DAMPER AT DIFFUSER AS REQUIRED. G MECHANICAL CONTRACTOR SHALL FURNISH AND INSTALL VOLUME DAMPER AT TRUNKLINE TAKE —OFF. 16 RETURN AIR OPEN TO SPACE. FURNISH AND INSTALL SCREEN. 17 NEW OUTSIDE AIR DUCT AND LOUVER. OUTSIDE AIR DUCT SHALL BE EQUIPPED WITH AN AUTOMATIC SHUT—OFF DAMPER PER FBCE C403.2.4.3. CONTRACTOR SHALL VERIFY SIZE OF LOUVER REQUIRED. G FURNISH AND INSTALL NEW EXHAUST FAN AS REQUIRED. FAN SHALL 10'-0" AWAY FROM ANY INTAKE. VERIFY EXACT LOCATION IN FIELD. 19 EXHAUST FAN VARIABLE SPEED FAN SWITCH. SWITCH SHALL BE WIRED INTO PET AREA LIGHTING AS REQUIRED. 20 AHU DRAIN PAN UNDER UNIT. PAN SHALL BE EQUIPPED WITH A FLOAT TO SHUT DOWN THE UNIT UPON ACTIVATION. 21 FURNISH AND INSTALL NEW EXHAUST DUCT UP TO EXHAUST FAN ON ROOF. VERIFY LOCATION IN FIELD. MECHANICAL MATERIALS DUCTWORK: DUCTWORK: RIGID: GALVANIZED SHEET METAL OR DUCT BOARD, IN ACCORDANCE WITH ASHRAE, SMACNA AND STATE CODE REQUIREMENTS FOR LOW PRESSURE DUCTWORK (1" WC). DUCT BOARD SHALL BE QUIETR TYPE 475 (1" THICKNESS) OR EQUIVALENT. R-6.5 FLEXIBLE: WIREMOLD TYPE JPL FLEX R-6 OR EQUAL FLEXIBLE CLASS 1 AIR DUCT. SHALL MEET STATE LOCAL CODES. EXHAUST FAN SCHEDULE UNIT NO. MANUFACTURER MODEL CFM PRESSURE DROP DRIVE WATTS/HP RPM VOLTAGE CONTROL NOTES INCHES WC. EF-1 GREENHECK G-120 1200 0,5" DIRECT 1/6 HP 1265 120 WALL O OR EQUIVALENT SWITCH EF-2 GREENHECK G-120 1600 0,5" DIRECT 1/6 HP 1635 120 WALL 0 OR EQUIVALENT SWITCH NOTES: O1 COMPLETE FAN WITH INTEGRAL BACKDRAFT DAMPER(AS REQ.), DISCONNECT SWITCH AND VARIABLE SPEED MOTOR. 20 PROVIDE FACTORY WALL VENT, BACKDRAFT DAMPER, BIRDSCREEN, & DISCONNECT. NEW SPLIT SYSTEM SCHEDULE (TYPICAL FOR 2) MARK MFR. AND MODEL N0. NOMINAL TONS SA CFM OSA CFM COOLING CAPACITY HEATING CAPACITY ELECTRICAL APPROX. OPER. REMARKS SENSIBLE TOTAL EER/ INPUT/OUTPUT VOLT PH. EVAP. FAN COMPRESSORS CONDENSER FAN CIRCUIT FLA/HP QTY. RLA LRA QTY. HP LRA (BTUH) (BTUH) SEER/ AMPS LBS. AHU #2 FEM4X6000BL — 2000 1200 — 10 KW 208 1 3/4 HP — — — — — — 66 150 D 3 4 5 6 7 OR EQUAL COND. #2 HEIL N4H660GK 5 — 60.0 12.0 208 1 1.4 1 — — 1 — 152 37.5 294 2 4 5 9 OOOO OR EQUAL AHU #3 HEIL FME4X3600BL — 1200 200 — — — 10 KW 208 1 3/4 HP — — — — — — 63.6 150 O 2 3 4 O 6 7 OR EQUAL COND. #3 HEIL N4H636GKP 3 — 36.0 12.0 208 1 1.4 1 — — 1 — 152 23.7 245 2 4 5 8 OOOO OR EQUAL O PROVIDE 5 YEAR COMP. WARRANTY O HVAC EQUIPMENT SHALL BE EQUIPPED WITH LOW AMBIENT KITS. O PROVIDE 2" THICK THROWAWAY FILTERS O COMPLETE WITH HEATER #EHKIOAKB O PROVIDE VIBRATION ISOLATORS FOR SUSPENDED OR FLOOR MOUNTING (AS REQUIRED) O CONDENSER UNITS SHALL BE 2—STAGE COOLING. O SYSTEM RATED ® AIR CONDITIONS 82.4' EDB, 66.6' EWB, 110' AMBIENT O COMPLETE WITH ALL FACTORY SAFETY & OPERATING CONTROLS AS REQUIRED— MOUNTING OF UNITS SHALL BE AS REQUIRED W/MINIMAL IMPACT TO EXISTING STRUCTURE DIFFUSER/REGISTER SCHEDULE MARK SERVICE TYPE MODULE/FACE BACKPAN MFGR. & MOD. NO. BORDER PATTERN NOTES COMMENTS SIZE TYPE A SUPPLY SQUARE 24" X 24" 18" X 18" TITUS TMS—AA 3 — LAY —IN 4—WAY 1,2 OR EQUIVALENT B SUPPLY DUCT — SEE PLAN TITUS TMR—AA 3 — LAY —IN — — OR EQUIVALENT C SUPPLY SQUARE 12" X 12" 9" X 9" TITUS TMS—AA 3 — LAY —IN 4—WAY 1,2 OR EQUIVALENT BORDER CORE AREA D EXHAUST ROUND 12" SEE PLAN TITUS TMR—AA 3 — LAY —IN _ _ OR EQUIVALENT F EXHAUST SQUARE 24" X 24" SEE PLAN TITUS PAR —AA 3 — LAY —IN _ _ OR EQUIVALENT G EXHAUST SQUARE 12" X 12" SEE PLAN TITUS PAR —AA 3 — LAY —IN _ _ OR EQUIVALENT NOTES: DIFFUSER REGISTER TYPE 1. PROVIDE WITH RADIAL DAMPER 2. PROVIDE THE OPTIONAL BD ACTUATORS TO ALL SUPPLIES FOR OWNER TO E BE ABLE TO ADJUST BOWTIE DAMPERS BY HAND BELOW CEILING. 960 RETURN AIR *DUCT QUANTITY (CFM) AIR QUANTITY (CFM) 22X22 CONNECTION CORE AREA (8'-0" MAX FOR FLEX DUCT) � 1 O W 2 N N to z Z Q ! co� co�W C3 x z fp C= F— I Nd Z W 0 co cn (1)O O Q T Lo con _c�0 r_ rFo 00 LLz II. oU i i i j I CERTIFIED BY: I. •` IL 6 • 0 �d %� •. V O ,,������s►�n PR�".V I I 1 I i i DRAWN BY: STAFF � J i i i 6440 FORT KING ZEPHYRHILLS, FL 33542 DARREN & LUANN Owner ZEPHYR HILLS MECHANICAL PLAN m 10 1 i 3 .I 1 I 1. ,I.I IIA ,i ...I "III, - 1 '! Software Version .1.. r nCOMcheck 4/ Interior Lighting Compliance Certificate Project Information Energy Code: 90.1 (2016) Standard Project Title; Houndstown Project Type: Addition Construction Site: Owner/Agent: Designer/Contractor: 6440 Fort King Don Penn PE Zephyrhills, FL 33542 Don Penn Consulting Engineer 1301 Solana Blvd Bldg 1/Suite 1420 Westlake, TX 76262 Allowed Interior Lighting Power A B C D Area Category Floor Area Allowed Allowed Watts (ft2) Watts 1 ft2 (B X C) 1-Salon (Retail:SalesArea) 5690 1,22 6942 Total Allowed Watts = 6942 Proposed Interior Lighting Power A B C D E Fixture ID : Description I Lamp J Wattage Per Lamp / Ballast Lamps/ # of Fixture (C X D) Fixture Fixtures Watt. I 1-Salon (Retaii:Sales Area) . LED 3: A: Existing Lt: Other: 1 53 26 1378 - LED 1: B: 2'x4' Troffer: Other: 1 9 48 432 1. LED 2: C: Wall Sconce: Other: 1 14 26 350 LED 4: D: EX 8 linear: Other: 1 7 36 252 Incandescent 1: X: Emergenc light: Other: 1 3 5 15 Compact Fluorescent 3: X1: Exit: Other: Electronic: 1 3 5 15 Total Proposed Watts = 2442 Interior Lighting Compliance Statement Compliance Statement., The proposed interior lighting design represented in this document is consistent with the building plans specifications, and other calculations submitted with this permit application. The proposed interior lighting systems have been designed to meet the 90.1 (2016) Standard requirements in CO�i� 1.5.4 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Don Penn, P.E. na /1 A /9n29 Name - Title Signature Date Project Title: Houndstown Data filename: E:\2022 Jabs\Houndstown\Zephyr Hills FL\Zephyr Compliance.cck 1 iH3 h Im act (Tier 1} 2=Medium im act Tier 2 3 Low Impact aci Tier 3 COMcheck r4 Version 4.1.5. 8/0' 6 Mechanical Compliance Certificate Project Information Energy Code: 90.1 (2016) Standard Project Title: Houndstown Location: Zephyrhills, Florida Climate Zone: 2a Project Type: Addition Construction Site: Owner/Agent: Designer/Contractor: 6440 Fort King Don Penn PE Zephyrhills, FL 33542 Don Penn Consulting Engineer 1301 Solana Blvd Bldg 1/Suite 1420 Westlake, TX 76262 Mechanical Systems List Quantity System Type 8r Description 1 HVAC System 1 (Single Zone): Heating: 1 each - Duct Furnace, Electric, Capacity = 34 kBtu/h No minimum efficiency requirement applies Cooling: 1 each - Split System, Capacity = 60 kBtu/h, Air -Cooled Condenser, Air Economizer Proposed Efficiency =13.00 SEER, Required Efficiency: 13.00 SEER Fan System: None 1 HVAC System 2 (Single Zone): Heating: 1 each - Duct Furnace, Electric, Capacity = 34 kBtu/h No minimum efficiency requirement applies Cooling: 1 each - Split System, Capacity= 60 kBtulh, Air -Cooled Condenser, Air Economizer Proposed Efficiency = 13.00 SEER, Required Efficiency: 13.00 SEER Fan System: None 1 HVAC System 3 (Single Zone): Heating: 1 each - Duct Furnace, Electric, Capacity = 34 kBtulh No minimum efficiency requirement applies Cooling: 1 each - Split System, Capacity = 36 kBtu/h, Air -Cooled Condenser Proposed Efficiency = 13.00 SEER, Required Efficiency: 13.00 SEER Fan System: None 1 Water Heater 1: Gas Storage Water Heater, Capacity: 30 gallons, Input Rating: 90 kBtu/h Proposed Efficiency: 80.00 % Et, Required Efficiency: 80.00 % Et Mechanical Compliance Statement Compliance Statement: The proposed mechanical design represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed mechanical systems have been designed to meet the 90.1 (2016) Standard requirements in COMcheck sion 4.1.5.4 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Don Penn, P.E. 03/18/2022 Name - Title Signature Date Report date: 03/18/22 Project Title: Houndstown Report date: 03118/22 Page 1 0 13 Data fil na e: E: 2022 o s H n t h it r li n k P f f e m \ b ou ds own e r Hills FL\Zephyr h Com a ce.cc Page 2 0 13 \ !Z 1 9 I 1 P Y p Y P 9 Project Title: Houndstown Report date: 03118/22 Data filename: E:\2022 Jobs\Houndstown\Zephyr Hills FL\Zephyr Compliance.cck Page 6 of 13 I Eott s i3. MIM', real ,Y# ,. K�f� , , •' . .§. i'59 ::: i ssrrs �__ .:. r4 :A Efh3€Y :. i lk , , , ..,, z I€a fA 11­i4§ ,,..,.. ..., 6,4.3'si.2 :Thermostatic controls have a 5 °F ZComplies Requirement will be met. iIFUP ndeadband, ❑Does Not i I ❑Not Observable ❑Not Applicable , i f.R.3.2 _ __ ......... Temperature controls have setpoint MComplies ........ ........ _........... ......... _.............. Requirement will be met. (F!20ja overlap restrictions, ❑Does Not ❑Not Observable ❑Not Applicable i 6 4 33 1 ........ .. ........ HVAC systems equipped with at least ... ................... :MComplies ....I ...... .......................... ........... ...................................................... Requirement will be met. i(FI21j3 `:one automatic shutdown control i❑Does Not j ❑Not Observable ° I 1.1.❑Not Applicable ; „a, 6 4,3,3 2 _..._...._.......,___._......_.... _ •Setback controls allow automatic _,,.__, _ ,,,.. MComplies __....__.._. _. _.___,.._ ............_ _..__.._ . _. __ Requirement will be met. ; restart and temporary operation as ❑Does Not ifFI22] required for maintenance. ❑Not Observable ❑Not Applicable •4.3,12 ..._ - Air economizer has a fault detection ❑Complies - - --.-- Exception: Requirement does not apply. [F120{1j3 '1. and diagnostics (FDD) system (see ❑Does Not details for configuration and ❑Not Observable ;operational requirements). MNot Applicable 16.4,3;22 ................I..................._..... `Air economizer has a fault detection ...... . .... ❑Complies ..... I. ..... ... .._.............. ......... :Exception: Requirement does not apply, ICFl200j3 :and diagnostics (FDD) system (see ❑Does Not : ! i details for configuration and ❑Not Observable operational requirements). MNot Applicable „ 64,35 _,... _................................. ---- When humidification and --- -----.. MComplies .. ---- ----... ... .... _ _ ---------- Requirement will be met. I ;[Fl61 dehumidification are provided to a ❑Does Not zone, simultaneous operation is Observable prohibited. Humidity control prohibits :❑Not ❑Not Applicable he use of fossil fuel or electricity to produce RH > 30% in the warmest I ( !zone humidified and RH < 60% in the 3 g,,, :coldest zone dehumidified. ............ .. ...... ........ ..... ...... ....... .. ............................ .................................................. 6 7 211 Furnished HVAC as built drawings MComplies Requirement will be met. ;[FIn- submitted within 90 days of system ❑Does Not .acceptance. ❑Not Observable:I €- g ❑Not Applicable �„ „ 6 7 2 2 Furnished O&M manuals for HVAC MComplies --- ........ -................................ Requirement will be met. ([FI8]'f systems within 90 days of system ❑Does Not i acceptance, ❑Not Observable I ❑Not Applicable : 6.7.2.3 ___...___ __.__._.__ __.____ ...._.. An air and/or hydronic system __ __.........:. MComplies . _ .. --.- -._ ---.- ..__-_------.-- .. .. ---- ................................ Requirement will be met. ' [FI9)1 balancing report is provided for HVAC❑Does Not systems serving zones >5,000 ft2 of Not Observable l . conditioned area. : 0 Applicable I i 6.7.2.4 .................... . ........ .. ......... HVAC control systems have been . ...._Nat .._ MComplies ....... _. ...... ._..... ....... -... ....... .......-_._ ....... ....... ........ I'll ...... ........ ....... -....... .....__........ .........................._........... Requirement will be met. [FI10]1 .tested to ensure proper operation, ❑Does Not calibration and adjustment of controls. . ❑Not Observable' ❑Not Applicable i7,4,43 ..... ........... .._............... ...... ........ ....--- ...... Public lavatory faucet water ..... , , -- MComplies ------ ------.. -- ------- -------- -------- : Requirement will be met. £[FI -11. ,temperature <=110°F. ❑Does Not ❑Nat Observable ❑Not Applicable 1 .H3gh Impact (Tier 1} ----- - 2 Medium Impact (Tier 2) 3 <.Low Impact (Tier 3) Project Title: Houndstown Report date: 03/18/22 Data filename: EA2022 jobs\Houndstown\Zephyr Hills FL\Zephyr Compliance.cck Page 11 of 13 ---- ------------ : 1 High Impact (Tier 1) 2.j; Medium Impact (Tier 2) 3 j Low Impact (Tier, 3j - Project Title: Houndstown Report date: 03/18/22 Data filename: EA2022 Jobs\Houndstown\Zephyr Hills FL\Zephyr Compliance.cck Page 7 of 13 .e, i._ e tsora ! .,,, ) <. Sinai ins action Corr€ lies Ir crmm gists sxtioa tfoxta. 1A p . lie„ _ W„ __ ...._.... W _ j __. , _ , .....__. 8 7 1 J(FI :6 Furnished as -built drawings for 'electric power systems within 30 days MComplies '❑Does Not .Requirement will be met. I of system acceptance. ❑Not Observable I i ❑Not Applicable _ 8 7.2 -_ ..._ _..- _ _... Furnished O&M instructions for ..._ _-- MComplies -----_.-- ------_-...__............_ _ Requirement will be met. j (F117]3 systems and equipment to the ❑Does Not building owner or designated ❑Not Observable, j '( representative. ❑Not Applicable 9.2,2.3 Interior installed lamp and fixture :MComplies See the In terior Lighting fixture schedule for values. [Fi18]1 ' lighting power is consistent with what `❑Does Not i is shown on the approved lighting �❑Not Observable; I i plans, demonstrating proposed watts :are ❑Not Applicable I I less than ore equal to allowed q <__________ _.....:watts.. 9.4.4 _. _..._..� At least 75% of all permanently ______. ❑Complies _..... _______. _ _, _. ___ _.__....... __ _. Exception: Requirement does not apply. [FI2011 installed lighting fixtures in dwelling ;❑Does Not units have >= 55 Im/W efficacy or a []Not Observable: >= 45 Im/W total luminaire efficacy. ZNotApplicable s _... _........_. 20 4 3 Elevators are designed with the __._ ❑Complies .__-._......_.... _.,_. Exception: Requirement does not apply. FF1�42 proper lighting, ventilation power, and ❑Does Not I ;standby made. i% ,11111 ;❑Nat observable I I : MNot Applicable i T 4 3 ___ _........._._ _.._ _ -__.- � ._. _._ First 8 ft of outlet in _._..__._.......__ ._....: MComplies _-_-______ _ __...._.__....__._.___..__........._............ ._..... _ ._._...___...._...._..-__; ' Requirement will be met. I Cix]451z %piping nonrecirculating storage system, or ❑Does Not ; branch piping connected to ' ❑Nat observable M.�1I :l., :�,,I �",­�",:��", ,.''.':,,.:,�"",i:I�::�::�,-::'::,�::::,',::�*,':-.,,*, recirculated, heat traced, or impredance heated piping is ❑Not Applicable j' insulated. __._ _ ___f Additional Comments/Assumptions: ---- -U --- ---- . - - - ..... ......... _ .., 1 High Impact (Tier 1) 2;,Medium Impact (Tier 2) � j,Low Impact {Tier,3) Project Title: Houndstown Data filename: E:\2022 Jobs\Houndstown\Zephyr Hills FL\Zephyr Compliance.cck Report date: 03/18122 Page 12 of 13 Software Version ... 6COMcheck �( Inspection Checklist Energy Code: 90.1 (2016) Standard Requirements: 100.0% were addressed directly in the COMcheck software Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. e �< E >Eri.$tE9EY . , f „ ,.. . Plan e,v. $£7°§ ti € 4AkikYY'e� 't Aa tirttlSt[$Si£+ 3 to iQ ,....__.' 4.2.2, Plans, specifications, and/or ®Complies .Requirement will be met. 16.4.4.2.1, calculations provide all information ❑Does Not E6.7.2 with which compliance can be [PR2]1 determined for the mechanical ❑Not Observable I systems and equipment and ❑Not Applicable i document where exceptions to the i standard are claimed. Load calculations per acceptable engineering standards and handbooks. -................................. ..- ------ - -_.... 4,2.2, . plans specifications, and/or --- -.----- . - -- ----- ------------- ----- - ---_...._.. ®Complies :Requirement will be met. l7.7,1, calculations provide all information jQDoes Not [10,4.2 with which compliance can be ❑Not Observable' 1[PR311 determined for the service water `• ❑Not Applicable i heating systems and equipment and ;document where exceptions to the i standard are claimed. Hot water system sized per manufacturer's sizing guide. - --- -- ----- ----- r422 : Plans, specifications, and/or ------- ---- - ----- ------ ------ ---- ------ ------_ ®Complies :Requirement will be met. $4 1.i calculations provide ail information ❑Does Not EB 4 1,2 with which compliance can be Eft 7 -11 determined for the electrical systems ! ❑Not Observable' ["A61 and equipment and document where :❑Not Applicable I -1 exceptions are claimed. Feeder connectors sized in accordance with approved plans and branch circuits _ sized for maximum drop of 3`Y". €4,2.2, Plans specifications, and/or ZComplies :Requirement will be met. 9.4.3, 9 7 !calculations provide all information El Does Not [PR4]1 with which compliance can be ❑Not Observable :determined for the interior lighting and electrical systems and equipment ❑Not Applicable j and document where exceptions to Ej the standard are claimed. Information provided should include interior , lighting power calculations, wattage of; I ;bulbs and ballasts, transformers and i control devices. _ _,_ 6.. _.,__ _...._._ _ ____ __ _______._..,.,.,. I[PR5]i systems commissioning included on ❑Does Not 1 I I the plans or specifications for projects ❑Not Observable >=50,000 ft2. j ; - - _ ___.__,._.___.-_-_ - _ ❑Not Applicables _.__._.__,_____...__....._...._ _ _._ _ Additional Comments/Assumptions: r-,_....................._.._._._.,.______ I 1 iH3gh Impact (T3er 1)iii ..., ._.___.._........--____._._ ..._.........�_....... ; 'Medium Impact (Tier Z) T 3 ;Low Impact (Tier 3) Project Title: Houndstown Report date: 03/18/22 Data filename: EA2022 Jobs\Houndstown\Zephyr Hills FL\Zephyr Compliance.cck Page 3 of 13 II :..- -- .------ ---- - - ------ - I :High impact (T3er 1) 2 j�Med3um Impact (Tier 2) , 3 `/Low Impact (Tier 3) Project Title: Houndstown Report date: 03118/22 Data filename: EA2022 Jobs\Houndstown\Zephyr Hills FL\Zephyr Compliance.cck Page 8 of 13 i6;4 7 'Freeze protection and snow/ice xComplies ; Requirement will be met. UP09js :melting system sensors for future i❑Does Not connection to controls. i -Not Observable ❑Not Applicable Additional Comments/Assumptions: _ -._ ....,..._.,_._..__ ________. _---_..__ _______ 1 H1 h Im act Ti-'Ti-). Medium im act Tier 2 Low Im act Tier 3 ( ( ) ( ) 9 P ) 1 P P Project Title: Houndstown Report date: 03/18/22 Data filename: E:\2022jobs\Houndstown\Zephyr Hills FL\Zephyr Compliance.cck Page 4 of 13 Additional Comments/Assumptions: _......._ _.... .................................. ...... 1 Hi h Impact Tier 1 2 Medium Im act Tier 2 3 Low Im act Tier 3 (( 9 P ( ) P ( ) P ( ) L_ _..__..............................._.1 _. ____........_ Project Title; Houndstown Report date: 03/18/22 Data filename: E:\2022jobslHoundstown\Zelphyr Hills FL\Zephyr Compliance.cck Page 9 of 13 Additional Comments/Assumptions: _.___ _..... _ __ __.___........._ _.._..... __._._ _ _____ _.__......,_._...._.._...._.......__..._....,...,_......_ __, 1 High impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low impact (Tier 3) Project Title: Houndstown Report date: 03118122 Data filename: EA2022 jobs\Houndstown\Zephyr Hills FL\Zephyr Compliance.cck Page 5 of 13 eckisx F B4sg fp €trtaf ItrsI'llpetitrt orpfiet 11 .11 Ceras#n/Asulttpts _, i 4 2 _: ,_. ,._ _. _....... 'At least 50% of all 125 volt 15- and MComplies _......, ..._.,..___,_......._,.....,._INA_ .__ ,. _._._._11 _. Exception: Space type is not private office, open office, or €E) I ,, .20-Amp receptacles are controlled by ❑Does Not computer classroom: a ?an automatic control device. ❑Not Observable a ❑Not Applicable !�11.111 New buildings have electrical energy❑Complies Exception: Buildings 25,000 ft2. [EL111 ' use measurement devices installed. ❑Does Not Where tenant spaces exist, each ❑Not Observable tenant is monitored separately, in buildings with a digital control system ®Not Applicable : I the energy use is transmitted to to I �eontrol system and displayed [ £ 9raphicallY. _.. - 9 41 :.Automatic control requirements ®Complies Requirement will be met. II i[ELljz prescribed in Table 9,6.1, for the ❑Does Not ' appropriate space type, are installed. Mandatory lighting -]Not Observable; E controls (labeled ❑Not Applicable i i as'REQ') and optional choice controls 1. (labeled as 'ADD/' and 'ADD2`) are i implemented. ? 41.: ........ ........ ............. : Independent lighting controls installed ............................ ;MComplies ........... .............. ......I... ...... Requirement will be met. (EL2ja :per approved lighting plans and all ❑Does Not _111,ii „manual controls readily accessible and ❑Not Observable. , visible to occupants. ❑Not Applicable 9 4 1 if Daylight areas under skylights and ❑Complies Exception: Requirement does not apply. [EL1311 roof monitors that have more than ❑Does Not ' 150 W combined input power for ❑Not Observable: }._....... .general lighting are controlled by ;photocontrois. ®Not Applicable ._...._. 9.4,1 3 __.......__-_._.__..__._._..._....._....._...___._....__...._........... Separate lighting control devices for ......__..............__........._.............._...__..__-_.__.._......__..__.____---...__.....-...__..-_-_-..._.--__..._.._..__................_...............: :MComplies 'Requirement will be met. [EL4]1 .specific uses installed per approved ❑Does Not lighting plans. ❑Not Observable ' ❑Nat Applicable j_ j9.6.2 _ _____ _ _____ !Additional interior lighting power _. MComplies ___-_-_-_-__I:: __.,_.._ _ _ .._ ... _,_ ._ Requirement will be met. ':, [EL8]' allowed for special functions per the ❑Does Not 'approved lighting plans and is :automatically controlled and ❑Not Observable 3 separated from general lighting, ❑Not Applicable :. _.. ilia 4 1 Electric motors meet requirements .............. .......... :MComplies !Requirement I..... .... I.---- .. will be met. (L9]2 where applicable. ❑Does Not ❑Not Observable Y in ❑Not Applicable ! Y--_m - Additional Comments/Assumptions'�� ................. -. T ... ......... _-- ----- ­­_­­_­­­­­ i 1 1 High Impact (Tier 1) 2 :j Medium Impact (Tier 2) , 3 ;Low Impact (Tier 3) Project Title: Houndstown Data filename: E:\2022 Jobs\Houndstown\Zephyr Hills FL\Zephyr Compliance.cck Report date: 03/18/22 Page 10 of 13 M U o� N N Z W V Z W >`t� Z mrXnNW (Dv c F- I Z O W a O Y U) Q u7 o . I Fr 00 CO in00 O Z CERTIFIED BY: DRAWN BY: STAFF 6440 FORT KING ZEPHYRHILLS, FL 33542 DARREN & LUANN Owner L-JANSEN GEHRING 317.747.0555 --------I ZEPHYR HILLS 'I 1 i �___ ENERGY FORMS M 101 A 0-1 MOP SINK F NOTE: 1. ALL FIXTURES DISCHARGING DOWNSTREAM FROM A WATER CLOSET SHALL BE INDIVIDUALLY VENTED PER 901.2 2. REDUCED PRESSURE ASSEMBLY BACKFLOW PREVENTERS ARE REQURIED TO BE INSTALLED WITH ALL SALONS. TYPICAL PLUMBING SANITARY ISOMETRIC N.T.S. SINK 4" WC 2" PLUMBING EQUIPMENT SCHEDULE MAKE & MODEL NUMBER ITEM DESCRIPTION CAPACITY FUEL TYPE BTUIHR NOTES (OR APPROVED EQUAL) WATER HEATER A.O. SMITH TANK WATER HEATER ON STAND. STAND BY 40 GALLONS ELECTRIC 4,500 WATTS OR APPROVED EQUAL EH-1)-(IFREQUIRED) ENS-40 CONTRACTOR HOT WATER BELL & GOSSETT RE-CIRC PUMP PL-30 HOT WATER RE -CIRCULATION PUMP 1/12 HP OR APPROVED EQUAL SPEED QUEEN 11.7 GALLONS PER CYCLE, WASHER/DRYER STEBCASP173TWOI COMBINATION WASHERIDRYER MACHINE 3.8 GAL./CU.FT, OR APPROVED EQUAL KRAUS MAXIMUM 2.2 GPM @ 60 PSI SINK PREP SINK W/DELTA #297247 FAUCET 1.0 GPM KTM33 OR APPROVED EQUAL MUSTEE MOP BASIN 19CF MOP SINK COMPLETE WITH FAUCET AND STOPPER OR APPROVED EQUAL EZ FLO WITH 2.0 LAMINAR FLOW MOP FAUCET 10361 CONTROL OR APPROVED EQUAL FLOOR DRAIN SURE SEAL 4" INLINE FLOOR DRAIN TRAP SEAL WITH TRAP SEALER SS4009V PROPRIETARY EPDM RUBBER DIAPHRAGM OR APPROVED EQUAL OATEY WASHER BOX OR APPROVED EQUAL F1960 ZURN WILKINS TEMPERED WATER LIMITING DEVICE. CONFORMS TEMPERED WATER REQUIRED TEMPERED WATER MV ZW3870XLT TO ASSE 1070. 100° MAXIMUM OATEY ICE MAKER BOX OR APPROVED EQUAL 39149 ZURN BACKFLOW OR APPROVED EQUAL 975XL2 FI 0L LINT TRAP OR APPROVED EQUAL 160 MASTER EQUIPMENT POLYPRO LIFT GROOMING TUB GROOMING TUB OR APPROVED EQUAL TP5856 KOHLER ELONGATED FLOOR MOUNT TOILET WATER CLOSET OR APPROVED EQUAL K-3658-0 KOHLER GREENWICH SINK, WALL MOUNTED LAVATORY OR APPROVED EQUAL K-2032-0 NOTES: 1. WASHER/DRYER SHALL BE IN COMPLIANCE WITH SECTION 504.3 OF THE 2009 IMC. 2. CONTRACTOR SHALL VERIFY WITH LOCAL CODES AND/OR INSPECTOR IF THE SURE SEAL TRAP SEALER IS ACCEPTABLE. PLAN NOTES: OCONNECT TO EXISTING SANITARY MAIN AS REQUIRED. OSANITARY PIPING SHALL BE RAN UNDER SLAB. OSANITARY PIPING SHALL BE RAN IN WALL. O4 EXISTING TO REMAIN, CAP ALL UNUSED EXISTING CONNECTIONS. VERIFY LOCATION IN FIELD. O3" FLOOR DRAIN, TRAP PRIMER TO NEAREST SINK AND VENT AS REQUIRED. PLUMBING NOTES 1. ALL PLUMBING WORK TO BE DONE BY A LICENSED PLUMBING CONTRACTOR AND TO MEET ALL FEDERAL, STATE & LOCAL CODES. 2. THE CONTRACTOR SHALL OBTAIN ALL NECESSARY PERMITS AND SHALL PAY ALL REQUIRED FEES FOR THIS WORK. 3. THE CONTRACTOR SHALL FIELD VERIFY EXISTING CONDITIONS AND REPORT TO BANYAN CONSTRUCTION, IN WRITING, ANY DISCREPANCIES IMMEDIATELY UPONDISCOVERY. 4. KEEP VENT HEIGHT WITHIN SPECIFIED DIMENSIONS. 5. KEEP ALL ROUGH PLUMBING WITHIN SPECIFIED DIMENSIONS. 6. EXTEND ALL ROUGH PLUMBING FROM WALL. -AS NOTED- 7. PLUMBING CONTRACTOR TO VERIFY ALL FIELD MEASUREMENTS. 8. PLUMBING CONTRACTOR TO VERIFY PLUMBING REQUIREMENTS FOR ALL FIXTURES & EQUIPMENT PROVIDED BY OWNER. 9. WALL THICKNESS MAY VARY FROM PLAN AS SHOWN DEPENDING ON LOCAL REQUIREMENTS AND EXISTING CONDITIONS. 10. ALL SINKS FOR EMPLOYEES OR PUBLIC USE SHALL BE A MAXIMUM OF 6-,V' DEEP AND MOUNTED WITH THE TOP EDGE A MAXIMUM 34" A.F.F. SINK DEPTH DOES NOT APPLY TO LAVATORIES. 11. ALL FLUSH VALVE HANDLES FOR THE WATER CLOSETS SHALL FACE THE OPEN SIDE OF THE ROOM. G.C. TO PROVIDE POWER FLUSH TOILETS. 12. G.C. TO HAVE WATER TESTED TO DETERMINE IF WATER SOFTENER IS NEEDED. 13. G.C. TO PROVIDE GAS WATER HEATERS IF AVAILABLE. VERIFY SELECTION W/ OWNER. 14. BLOCKING FOR RESTROOM AND BREAKROOM SINKS SHALL BE BY PLUMBER. 15. WHEN APPLICABLE, ALL WATER LINES ON EXTERIOR WALLS TO BE INSULATED TO PREVENT FREEZING PLUMBING NOTES WATER PIPING SHALL BE SCHEDULE 40 CPVC UNLESS OTHERWISE NOTED. ALL HOT WATER PIPING TO BE INSULATED (IF APPLICABLE). PROVIDE SHUTOFF VALVES IN SUPPLY LINES TO ALL FIXTURES. ALL PLUMBING FIXTURES AND RELATED SYSTEMS TO BE FURNISHED, INSTALLED AND PLACED IN OPERATION BY THE PLUMBING CONTRACTOR. WATER HEATERS FURNISHED BY G.C. VERIFY ALL A/C CONDENSATION LINES REQUIRED AND INSTALLED TO EXTERIOR OF BUILDING IN A SLIGHTLY MANNER. WASTE WATER LINES TO BE SCHEDULE 40 PVC. VERIFY LOCATION OF ALL SEWER AND WATER CONNECTIONS PRIOR TO START OF WORK. PLUMBING CONTRACTOR TO VERIFY LOCATION OF ALL EXISTING SERVICE LOCATIONS AND SIZE DIMENSIONS ARE TO BE VERIFIED IN THE FIELD TO DETERMINE APPLICABILITY TO EXISTING AND PROPOSED SERVICE. ALL BRANCH PIPING SHALL BE PEX PIPING. ALL GAS PIPING SHALL BE SCHEDULE 40 BLACK STEEL PIPE. ACCESSABLE MAIN SHUT OFF VALVE TO BE LOCATED IN MECHANICAL ROOM 36"-48" A.F.F. 2 O _ NU O co 00 �LoZ W W W Z� OpTrNW �.. c� IZ Wo as co cio_ p �o o 2 — a, coI o= p r mcv)�i00 OZ CERTIFIED BY: D RAW N BY: STAFF 6440 FORT KING ZEPHYRHILLS, FL 33542 DARREN & LUANN Owner CONSTRUCTION JANSEN GEHRING 317.747.0555 ZEPHYR HILLS PLUMBING PLAN -WASTE 101 S al 3 1/2" 1/2" 1 MOP SINK NOTE: ALL PIPING ABOVE CEILING SHALL BE CPVC. ALL BRANCH PIPING SHALL BE PEC'S. TYPICAL PLUMBING WATER ISOMETRIC N.T.S. 3/4" PLAN NOTES: OEXTEND AND CONNECT TO EXISTING COLD WATER AS REQUIRED. VERIFY LOCATION IN FIELD. OEXISTING COLD WATER PIPING TO REMAIN. VERIFY EXACT LOCATION IN FIELD. OEXTEND AND CONNECT TO HOT WATER AS REQUIRED. VERIFY LOCATION IN FIELD. O4 EXISTING COLD WATER PIPING TO REMAIN. VERIFY EXACT LOCATION IN FIELD. PLUMBING NOTES 1. ALL PLUMBING WORK TO BE DONE BY A LICENSED PLUMBING CONTRACTOR AND TO MEET ALL FEDERAL, STATE & LOCAL CODES. 2. THE CONTRACTOR SHALL OBTAIN ALL NECESSARY PERMITS AND SHALL PAY ALL REQUIRED FEES FOR THIS WORK. 3. THE CONTRACTOR SHALL FIELD VERIFY EXISTING CONDITIONS AND REPORT TO SYMPATECO, INC., IN WRITING, ANY DISCREPANCIES IMMEDIATELY UPON DISCOVERY. 4. KEEP VENT HEIGHT WITHIN SPECIFIED DIMENSIONS. 5. KEEP ALL ROUGH PLUMBING WITHIN SPECIFIED DIMENSIONS. 6. KEEP ALL VERTICAL VENT PIPES WITHIN DISPENSARY, UTILITY, LAVATORY AREAS & NOT IN FINISHED SHAMPOO AREA. IF VENT RUNS OUTSIDE WALLS, GENERAL CONTRACTOR MUST BOX IN. 7. NECESSARY VACUUM BREAKERS ARE PROVIDED BY SYMPATECO, INC. TO BE INSTALLED BY PLUMBER, AT TIME OF SINK HOOK UP. 8. SYMPATECO, INC. SUPPLIES SINK WITH 4" TAIL PIECE, SHAMPOO HOSE & SPRAY, HAIR STRAINERS, HAIR TRAP & FAUCET FIXTURES. 9. EXTEND ALL ROUGH PLUMBING FROM WALL. -AS NOTED- 10. PLUMBING CONTRACTOR TO VERIFY ALL FIELD MEASUREMENTS. 11. PLUMBER TO PROVIDE ALL ROUGH -IN PLUMBING PRIOR TO INSTALLATION OF SHAMPOO CABINETS & RETURN AFTER CASEWORK INSTALLATION TO HOOK UP/ INSTALL SINKS AS NEEDED. 12. PLUMBING CONTRACTOR TO VERIFY PLUMBING REQUIREMENTS FOR ALL FIXTURES & EQUIPMENT PROVIDED BY OWNER & SYMPATECO, INC. 13. WALL THICKNESS MAY VARY FROM PLAN AS SHOWN DEPENDING ON LOCAL REQUIREMENTS AND EXISTING CONDITIONS. 14. PLUMBER TO PROVIDE PLUMBING SUPPLY LINE SHUT-OFF PER PLUMBING RUN. PLUMBER TO SHOW OWNER WHERE SHUT OFF VALVES ARE AND SHOW HOW VALVES OPERATE. 15. ALL SINKS FOR EMPLOYEES OR PUBLIC USE SHALL BE A MAXIMUM OF 6Y2" DEEP AND MOUNTED WITH THE TOP EDGE A MAXIMUM 34" A.F.F. SINK DEPTH DOES NOT APPLY TO LAVATORIES. 16. ALL FLUSH VALVE HANDLES FOR THE WATER CLOSETS SHALL FACE THE OPEN SIDE OF THE ROOM. G.C. TO PROVIDE POWER FLUSH TOILETS. 17. G.C. TO HAVE WATER TESTED TO DETERMINE IF WATER SOFTENER IS NEEDED. 18. G.C. TO PROVIDE GAS WATER HEATERS IF AVAILABLE. VERIFY SELECTION W/ OWNER. 19. BLOCKING FOR RESTROOM AND BREAKROOM SINKS SHALL BE BY PLUMBER. O 04 N CD � V t CD 00 Z Fn �hNa. W c i z Z�600 e r r 6) o -0 c')[000 W W U Z W �_ Z o W 0) 0 ¢r 0 0 pc o OZLL CERTIFIED BY: • LL 6' ;! W :toto °'o O a.:, • c V �+► c'j, 40 . DRAWN BY: STAFF 6440 FORT KING ZEPHYRHILLS, FL 33542 DARREN & LUAN N Owner ............... .............. ..... JANSEN GEHRING 317.747.0555 ZEPHYR HILLS PLUMBING PLAN -WATER 102