Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
6834 Gall Blvd (3)
ALTERATION FOR: I : 1. 1( 1 9! ZEPHYR PLACE, 6834 GALL BOULEVARD ZEPHYR HILLS, FL 33542 J _ PJE `.ter -a r ,.._ ✓ ' �'� _-1V77?'F^Q IL WORK SHALL COMPLY %�,TTT�J ALL REVAILING CODES, FLORIDA BUILDS CODE. NATIONAL ELECTRIC CODE A� CG"`-Y OF ZEPHYR HI [ L ; On rj!N' 1NC" =' APPROVE by Fire Marshal of Zephyrhills with C mments provided with plan(s) I 1 1 SHEET INDEX SHEET SHEET NAME Gill COVER SHEET, CODE CRITERIA & BLG, PROGRAM G1,2 NOTES & SPECIFICATIONS 01,3 NOTES & SPECIFICATIONS G1,4 NOTES & SPECIFICATIONS S-1 CONCRETE PLAN A1,1 LIFE SAFETY PLAN A2,1 ARCHITECTURAL FLOOR PLAN & SPECIFICATIONS A3.1 EQUIPMENT PLAN & SCHEDULE A3,2 EQUIPMENT SECTI❑NS & DETAILS A4,1 REFLECTED CEILING PLAN & SPECIFICATIONS A5.1 ENLARGED TOILET ROOM PLAN, ELEVATIONS & SPECS A6,1 DOOR & WINDOW SCHEDULE & DETAILS A7,1 ROOM FINISH SCHEDULE, WALL TYPES & DETAILS A7,2 WALL SECTIONS & DETAILS A7,3 WALL SECTIONS & DETAILS A7,4 INTERIOR ELEVATIONS P-1 PLUMBING FLOOR PLAN P-2 PLUMBING RISER DIAGRAM M-1 H,V,A,C, FLOOR PLAN M-2 MECHANICAL ROOF PLAN M-3 MECHANICAL DETAILS M-4 H,V,A,C, SCHEDULES, NOTES, DETAILS & LEGEND M-5 EQUIPMENT SPECIFICATIONS M-6 EQUIPMENT SPECIFICATIONS M-7 EQUIPMENT SPECIFICATI❑NS E-1 ELECTRICAL POWER PLAN E-2 ELECTRICAL LIGHTING PLAN & PANEL SCHEDULE FS-1 FIRE SPRINKLER PLAN REFERENCE CODES EXISTING BUILDING, FLORIDA EXISTING BUILDING CODE 2004 EDITION W/ 2006 REVISIONS BUILDING, FLORIDA BUILDING CODE 2004 EDITI❑N W/ 2006 REVISIONS PLUMBING, FLORIDA PLUMBING CODE 2004 EDITI❑N W/ 2006 REVISIONS MECHANICAL, FLORIDA MECHANICAL CODE 2004 EDITION W/ 2006 REVISI❑NS ELECTRICAL, NATIONAL ELECTRICAL CODE 2005 EDITION ACCESSIBILITY, FLORIDA ACCESSIBILITY CODE FOR BUILDING C❑NSTRUCTI❑N FBC 2004 EDITION W/ 2006 REVISIONS LIFE SAFETY, NFPA 101 LIFE SAFETY CODE 2000 EDITION ARCHITECTURAL DESIGN CRITERIA ISSUED 02-28-08 02-28-08 02-28-08 02-28-08 02-28-08 02-28-08 02-28-08 02-28-08 02-28-08 02-28-06 02-28-08 02-28-08 02-28-08 02-28-08 02-28-08 02-26-08 02-28-08 02-28-08 02-28-08 02-28-08 02-28-08 02-28-08 02-28-08 02-28-08 02-28-08 02-28-08 02-28-08 02-28-08 OCCUPANCY, ASSEMBLY GROUP A2 (SECTION 303) C❑NSTRUCTION TYPE, F,B,C, TYPE IIIB, FULLY SPRINKLERED (SECTION 602) N,F,P,A, TYPE III (0,0,0) WORK CLASSIFICATI❑N, ALTERATI❑N LEVEL 3 (SECTION 303) BUILDING PROGRAM I RESTAURANT THE PROJECT CONSISTS OF AN INTERI❑R BUILD OUT OF A COMPLETED SHELL STRUCTURE INT❑ A RESTAURANT (CICI'S PIZZA) WHICH WILL INCLUDE THE F❑LLOWING SPACES/ROOMS, ENTRY SERVING DINING KITCHEN GAME ROOM REST ROOMS ALTERATION AREA CALCULATIONS EXISTING BUILDING AREA = 6,795 S,F, GROSS PROPOSED ALTERATION AREA = 3,986 S.F. GROSS BUILDING KEY PLAN AREA IF ALTERATION 3,9" SF EXISTING 1-STORY 6,795 S.F. SHELL BUILDING VICINITY MAP 4 eE �q r - W �---��0om EiYlL _.o n 21OOft m ¢ +G�'Q'' �11 e -Ln - I a V]Kolssit Rd diis)A n Rd - — a-" J _ IT II 6r Fairview Heights Rd Fr' Tuck Tr! o o Nottin ham Trl 0' III South ds. -I �n r Pre Pond Rd' �Z~ BDU6etlla a q?111ingYf XpP, Estate T� i/� w L� i _ - �e Gra a ;� r Eyd silver`@@'I v i 61f,& CI uohUntry au -Rd U - Millar-Av a m }/ c p —� r pcc _ T- mI C'aflppe L SahaYA a LL I Sunvalla D zs a 39 Hanry Or S 1 18th4AvaCe' srRd Gs "th Ave � Seabrook- 'e o w Tara Ave '- hAv Dalabroolc ,va-� �- Betmar Acres `' II Go f-Club -�' Ll 11th Ave Aster Av 0 rcen r .� z, L2005 hgnC)usst.corn Inc-, O2005 NAVTF:O f o v _ U� m o 0) y N � � co JN 06 a X m U J LL o o c c o _c C° > N N m ? 3 00 U � U a c Q 0 O L a o C0 J LL m 0 Ua in \� / co OL 0 � U Z 00 Cn U O � � o o c o � J C U J C Q O L0 ;J J J LL U 0 c i c 0 s` 0 0 N Q J U_ J LO Q co co u- NC)JU N UQ = LL O m O_ — J = w Q U Q� ��_ LU oo LLJ N co N Revisions: W :2 O� U U �O W W C0 Q W W O� L1 Project Number 07059 Date 12-06-07 Sheet Number G1.1 GENERAL NOTESi 1. TENANT'S GENERAL CONTRACTOR (T.G,C.) TO PROVIDE AND INSTALL ITEMS NOT SPECIFICALLY NOTED OTHERWISE TO MAKE FOR COMPLETE SYSTEMS, RESPONSIBILITIES ARE LISTED FOR CLARIFICATION AND D❑ NOT RELIEVE T,G,C, OF THE RESPONSIBILITY TO COORDINATE THE WORK AND MATERIAL DELIVERY OF ALL SUBCONTRACTORS. 2, T,G,C, SHALL BE RESPONSIBLE FOR COORDINATING DELIVERY OF ALL FRANCHISEE (TENANT) FURNISHED ITEMS WITH THE CICI'S SUPPORT OFFICE CONSTRUCTION DEPARTMENT, AND TO NOTIFY THE SAME IMMEDIATELY OF ANY DELAYS OF A WEEK OR MORE IN THE CONSTRUCTION SCHEDULE. 3, T.G.C. SHALL RECEIVE, UNLOAD, AND STORE ALL TENANT FURNISHED ITEMS AND SHALL PROTECT THEM FROM DAMAGE AND PILFERAGE, 4. CONTACT JMC RESTAURANT DISTRIBUTION (972) 745- 4200 FOR INSTRUCTIONS ON HANDLING DAMAGES INCURRED DURING SHIPMENT OF TENANT FURNISHED ITEMS, 5. T,G,C. SHALL PAY ALL RESTOCK AND/OR DELIVERY CHARGES RESULTING FROM REFUSAL OR NON ACCEPTANCE OF PLANNED DELIVERY OF TENANT FURNISHED EQUIPMENT AND FIXTURES. 6, T,G,C, SHALL INSTALL TENANT FURNISHED ACRYLIC INTERIOR SIGNS USING DOUBLE STICK FOAM TAPE AT LOCATIONS DIRECTED BY TENANT, 7, T,G,C, SHALL INSTALL TENANT FURNISHED ART WORK & MENU BOARDS AT LOCATIONS DIRECTED BY TENANT. 8, T,G,C, SHALL ASSEMBLE AND INSTALL TABLES, SHELVES, EQUIPMENT, ETC, 9. T,G,C, SHALL PROVIDE AND INSTALL 8-3/4 IN, #10 SCREWS FOR EACH TABLE, 10, T,G,C, SHALL PROVIDE NATIONAL #121-210 ROPE HOOKS FOR INSTALLATION OF PIZZA PAN WALL RACK (2 REQUIRED PER RACK), 11. T,G,C, SHALL PROVIDE POSITIVE DRAINAGE TO ALL DRAINS, 12. EXTERIOR TO INTERIOR TRANSITIONS SHALL BE VERIFIED & CORRECTED IF REQ'D FOR HANDICAPPED ACCESSIBILITY, SEE GENERAL ACCESSIBILITY NOTES ON SHEET A3, 13. T.G.C. SHALL BE RESPONSIBLE FOR DEMOLITION AND REMOVAL OF EXISTING FIXTURES, ARCHITECTURAL FINISHES AND MECHANICAL/ELECTRICAL ITEMS NOT USED IN FINISHED CONSTRUCTION WORK, 14, COORDINATE ANY DEMOLITION WITH FINISHED CONSTRUCTION WORK, 15. T,G,C. SHALL LOCATE ALL MECHANICAL AND ELECTRICAL SERVICES AND DISTRIBUTION SYSTEMS WHETHER SHOWN OR NOT, AND SHALL PROTECT THEM FROM DAMAGE, T,G,C, SHALL BEAR ALL EXPENSE FOR REPAIR OR REPLACEMENT OF OTHER UTILITIES OR OTHER PROPERTY DAMAGE BY OPERATIONS IN CONJUNCTION WITH THE PERFORMANCE OF THE WORK. 16, PROVIDE REQUIRED STRUCTURAL SUPPORT FOR NEW HVAC UNITS AND CONDENSERS ON ROOF. COORDINATE WITH LANDLORD'S ROOFER. 17. T,G,C, SHALL INSTALL WALK-IN COOLER ON BARE SLAB. COOLER SCREED (TRACK) SHALL BE SET IN A CONTINUOUS BED OF BUTYL RUBBER CEMENT, COOLER WALLS SHALL THEN BE ERECTED ON SCREED PER MFR'S. INSTALLATION INSTRUCTIONS, 18. 2 HEAVY DUTY ADHESIVE BACKED FELT STRIPS (AVAILABLE AT LOWES BUILDING CENTER) AT EACH TABLE ON PERIMETER OF DINING ROOM, 19. ALL WALLS CONTAINING PLUMBING (WET WALLS) SHALL BE CLAD W/WATER RESISTANT GYP. BD. 20. T,G,C. SHALL BE RESPONSIBLE TO COORDINATE WITH ALL TRADES AND VERIFY THAT ALL EQUIPMENT SHIPPED TO THE SITE IS COMPATIBLE WITH MECHANICAL, ELECTRICAL AND PLUMBING SYSTEMS PRIOR TO INSTALLATION OF SAID EQUIPMENT, IN THE EVENT OF ANY DISCREPANCIES, THE T.G.C. SHALL IMMEDIATELY CONTA CT T DESIGNER BEFORE PROCEEDING, 21, T,G,C, SHALL INSTALL SILICONE SEALANT @ ALL MATERIAL TRANSITIONS, GAPS, OPENINGS & PENETRATIONS (INCLUDING WOOD TRIM TO LAMINATE CONDITIONS), 22, T.G,C, SHALL CAULK JOINT BETWEEN CEILING GRID & FRP WALL PANELS IN ALL KITCHEN & RESTROOM AREAS, 23, INSIDE OF ALL CABINETRY SHALL RECEIVE WHITE MELAMINE EXCEPT UNDERSIDE OF BUFFET & BEVERAGE STATION COUNTER TOP, 24. T.G,C, SHALL LIGHTLY SAND ALL OUTSIDE CORNERS ON WOOD TRIM MAKING WOOD FREE OF SPLINTERS AND SHARP CORNERS 1.0 GENERAL DEFINITIONS 1.1 'PROVIDE' AND 'FURNISH' SHALL MEAN TO PURCHASE AND LOCATE AN ITEM ON THE JOBSITE. 1,2 'INSTALL' SHALL MEAN TO PHYSICALLY INSTALL THE ITEM, AND TO CONNECT ALL REQUIRED SERVICES TO MAKE THAT ITEM FULLY FUNCTIONAL. 1.3 'NEW STORE DEVELOPMENT' SHALL MEAN CICI ENTERPRISES, INC'S NEW STORE DEVELOPMENT DEPARTMENT, 1.4 A.F.F. SHALL MEAN 'ABOVE FINISHED FLOOR' 1.5 UNLESS SPECIFICALLY NOTED OTHERWISE, ALL ITEMS SHALL BE FURNISHED AND INSTALLED BY THE T,G.C. 1.6 'T.G.C.' SHALL MEAN THE TENANT GENERAL CONTRACTOR 1.7 THE TERM 'OWNER' OR 'FRANCHISEE' SHALL BE SYNONYMOUS, 2.0 INSURANCE PER CONTRACTUAL AGREEMENT BETWEEN OWNER & GENERAL CONTRACTOR. 3.0 PROGRESS PAYMENTS PER CONTRACTUAL AGREEMENT BETWEEN OWNER & GENERAL CONTRACTOR, 4.0 SUBCONTRACTOR APPROVAL THE OWNER AND/OR NEW STORE DEVELOPMENT RETAINS THE RIGHT TO REJECT THE USE OF ANY SUBCONTRACTOR FOR ANY REASON. THE T.G.C. SHALL EMPLOY SUBCONTRACTORS WHO ARE LICENSED IN THE STATE WHERE THE JOB IS LOCATED, THE T.G.C. SHALL ASSUME FULL RESPONSIBILITY TO INSURE THE VALIDITY OF ANY LICENSING INFORMATION AND INSURANCE COVERAGE INFORMATION GIVEN BY HIS SUBCONTRACTORS PRIOR TO THE AWARD OF THE CONTRACT, THE T.G.C. SHALL SUBMIT TO THE OWNER AND NEW STORE DEVELOPMENT, PRIOR TO RECEIVING FINAL RETAINAGE, A LIST OF THE SUBCONTRACTORS WHO WERE EMPLOYED ON THE PROJECT, LIST SHALL INCLUDE COMPANY NAME, STATE LICENSE NUMBER, ADDRESS AND PHONE NUMBER, THE OWNER AND/OR NEW STORE DEVELOPMENT RETAINS THE RIGHT TO REJECT THE USE OF ANY SUBCONTRACTOR FOR ANY REASON, THE T,G.C. SHALL EMPLOY SUBCONTRACTORS WHO ARE LICENSED IN THE STATE WHERE THE JOB IS LOCATED, THE T,G.C. SHALL ASSUME FULL RESPONSIBILITY TO INSURE THE VALIDITY OF ANY LICENSING INFORMATION AND INSURANCE COVERAGE INFORMATION GIVEN BY HIS SUBCONTRACTORS PRIOR TO THE AWARD OF THE CONTRACT, THE T.G.C. SHALL SUBMIT TO THE OWNER, LANDLORD, AND THE NEW STORE DEVELOPMENT DEPARTMENT, PRIOR TO RECEIVING FINAL RETAINAGE, A LIST OF THE SUBCONTRACTORS WHO WERE EMPLOYED ON THIS PROJECT. LIST SHALL INCLUDE COMPANY, NAMES, STATE LICENSE NUMBER, ADDRESS AND PHONE NUMBER AND COPY OF SUBCONTRACTORS INSURANCE CERTIFICATE NAMING ALL AS AN ADDITIONAL INSURED, 5.0 COORDINATION OF TRADES IT WILL BE THE T.G,C.'S RESPONSIBILITY TO COORDINATE THE ACTIVITIES OF ALL CICI'S PIZZA CONSTRUCTION TEAM MEMBERS, THE TEAM INCLUDES, BUT IS NOT LIMITED TO, ALL SUBCONTRACTORS, SPECIALTY CONTRACTORS, EQUIPMENT SUPPLIERS, SERVICE PROVIDERS, LOCAL CODE ENFORCEMENT OFFICIALS, AND JOB VALIDATION INSPECTORS. THE T.G.C. SHALL PUBLISH WITHIN FORTY-EIGHT (48) HOURS OF THE CONTRACT BEING SIGNED, A JOB CONTACT LIST AND CONSTRUCTION SCHEDULE FOR THE PROJECTi THE COPY OF THE CONTACT LIST AND CONSTRUCTION SCHEDULE SHALL BE FAXED TO ALL OF THE CONSTRUCTION TEAM MEMBERS, 6,0 PROJECT COMPLETION AND VALIDATION THE PROJECT SHALL BE COMPLETED WHEN THE FOLLOWING VALIDATION PROCESSES, JOBSITE CONDITIONS, AND PAPERWORK ARE COMPLETED AND APPROVED BY THE NEW STORE DEVELOPMENT DEPARTMENT, 6.1 DEFICIENCIESi ANY DEFICIENCIES NOTED BY THE INSPECTOR(S) SHALL BE CORRECTED BY THE RESPONSIBLE PARTY IN A TIMELY FASHION. THE T,G.C. HAS FULL RESPONSIBILITY FOR COORDINATING ALL CORRECTIVE ACTION REQUIRED ON THE PROJECT, WHEN CORRECTIVE ACTION IS COMPLETED, THE T.G.C, IS TO RECEIVE WRITTEN NOTIFICATION FROM EACH SUBCONTRACTOR THAT THEIR PORTION OF THE PUNCH LIST IS COMPLETE. THE T.G.C. SHALL COORDINATE AND PAY FOR ANY NEEDED OR REQUIRED RE -INSPECTION (S). 6.2 PUNCH LISTi OWNER AND/OR OWNER REPRESENTATIVE (S) AGREES TO ISSUE ONE (1) CONSOLIDATED AND FINAL PUNCH LIST TO THE T,G.C. PUNCH LIST ITEMS MUST BE CORRECTED WITHIN TEN (10) DAYS OF THE DATE THE PUNCH LIST WAS WRITTEN, OWNER WILL WALK THROUGH THE STORE WITH THE T.G.C, AFTER THE PUNCH LIST HAS BEEN COMPLETED AND SIGN OFF ON EACH PUNCH LIST ITEM INDICATING THAT ALL HAVE BEEN CORRECTED, FINAL RETAINAGE WILL BE RELEASED ONCE THE OWNER HAS SIGNED OFF ON ALL PUNCH LIST ITEMS AGREEING THAT THEY HAVE BEEN COMPLETED. 6.3 LOCAL CODE ENFORCEMENT INSPECTIONt THE T,G.C. SHALL PROVIDE A COPY OF ALL INSPECTION REPORTS COMPLETED BY LOCAL CODE ENFORCEMENT OFFICIALS UPON COMPLETION OF THE PROJECT. IF A DEFICIENCY IS NOTED BY AN OFFICIAL, A COPY SHALL BE FAXED TO THE NEW STORE DEVELOPMENT DEPARTMENT WITH THE RESPONSIBLE SUBCONTRACTOR AND EQUIPMENT SUPPLIERS DESIGNATED PROJECT CONTACT, A COPY OF THE CERTIFICATE OF OCCUPANCY WILL BE PROVIDED TO THE LANDLORD AND TENANT, 6,4 AS -BUILT DRAWINGS, THE T.G,C, SHALL PROVIDE ONE (1) SET OF 'AS - BUILT DRAWINGS' OF MECHANICAL AND ELECTRICAL SYSTEMS TO THE OWNER UPON COMPLETION OF THE PROJECT. 7.0 GUARANTEE THE T,G,C, SHALL PROVIDE A WRITTEN GUARANTEE, EXTENDING FOR ONE (1) YEAR BEYOND DATE OF CERTIFICATE OF OCCUPANCY, WARRANTING THE PROJECT AGAINST DEFECTS IN MATERIALS AND WORKMANSHIP. THE T.G.C. AS REQUIRED SHALL PROVIDE MATERIALS AND LABOR TO EFFECT REPAIR AND REPLACEMENTS. ALL GUARANTEES OR WARRANTIES SHALL INSURE TO THE BENEFIT OF THE OWNER, 8.0 PERMITS & LICENSES THE T,G,C, SHALL CONTACT THE NEW STORE DEVELOPMENT TO OBTAIN THE PERMIT STATUS, THE T,G.C. IS THEN RESPONSIBLE FOR OBTAINING ALL NECESSARY DRAWINGS, SPECIFICATIONS, STAMPS AND SIGNATURES FOR OBTAINING ALL NECESSARY PERMITS AND LICENSES, COST OF ALL BUILDING PERMIT FEES SHALL BE SHOWN AS AN ALLOWANCE IN THE T.G.C.'S BID. 9,0 UTILITIES 9.1 THE T.G.C. SHALL PAY FOR ALL TEMPORARY SERVICE AND UTILITIES FOR THE PROJECT, 9.2 THE T.G.C, SHALL LOCATE ALL MECHANICAL AND ELECTRICAL SERVICES AND DISTRIBUTION SYSTEMS, WHETHER SHOWN ON THE PLANS OR NOT, AND SHALL PROTECT THEM FROM DAMAGE. THE T,G.C, SHALL BEAR ALL EXPENSES FOR THE REPAIR OR REPLACEMENT OF OTHER UTILITIES OR OTHER PROPERTY DAMAGE BY OPERATIONS IN CONJUNCTION WITH THE PERFORMANCE OF THE WORK. 10.0 EXISTING CONDITIONS THE T,G,C, ACCEPTS PREMISES AS FOUND, THE OWNER AND LANDLORD ASSUMES NO RESPONSIBILITY OR THE CONDITION OF THE BUILDING OR LIABILITY FOR LOCATION OF EXISTING UTILITIES, ROOF STRUCTURE, OR ELEVATION AT THE TIME OF BIDDING OR THEREAFTER, THE T.G.C. ACCEPTS PREMISE AS FOUND, 11,0 PROJECT SAFETY THE T.G,C. IS RESPONSIBLE FOR THE SAFETY, ACTIONS, AND CONDUCT OF THEIR EMPLOYEES AND SUBCONTRACTOR'S EMPLOYEES WHILE IN THE PROJECT AREA, ADJACENT AREAS, IN THE BUILDING, AND ITS VICINITY, 12,0 BUILDING AND ACCESSIBILITY CODES ALL WORK DESCRIBED BY THESE DOCUMENTS SHALL BE PERFORMED IN FULL ACCORDANCE WITH ALL APPLICABLE LOCAL, STATE, AND NATIONAL CODES, LAWS, AND ORDINANCES BEING ADOPTED BY THE BUILDING AUTHORITY HAVING JURISDICTION OVER THIS PROJECT. THE T,G.C. ASSUMES SOLE RESPONSIBILITY TO IDENTIFY ALL APPLICABLE CODES FOR EACH SUB -TRADE AS WELL AS LOCAL AND NATIONAL ACCESSIBILITY CODES AND PERFORMING ALL WORK ACCORDINGLY. 13.0 PLAN DIMENSIONS DIMENSIONS SHALL GOVERN THESE DRAWINGS AND THEY ARE NOT TO BE SCALED, THE T.G.C. SHALL VERIFY ALL EXISTING DIMENSIONS. SHOULD THERE BE DISCREPANCIES, THE T.G.C. SHALL NOTIFY THE NEW STORE DEVELOPMENT AND SHALL BASE BIDDING/PRICING ON THE MOST EXPENSIVE COMBINATION OF QUALITY AND/OR QUANTITY OF THE WORK INDICATED, 14.0 PLAN REVIEW THE T.G,C. SHALL REVIEW THE PLANS AND SPECIFICATIONS THOROUGHLY, MAKE A DETAILED SITE VISIT, AND SHALL IMMEDIATELY BRING ANY INCONSISTENCY, SITE LAYOUT PROBLEMS, OR ANY OTHER REQUEST FOR CLARIFICATION TO THE NEW STORE DEVELOPMENT FOR RESOLUTION PRIOR TO THE DELIVERY OF ANY BID. FAILURE TO D❑ S❑ SHALL CAUSE THE T,G.C, TO BE INELIGIBLE FOR REQUESTING EXTRAS RELATING TO SUCH MATTERS. 15.0 ENGINEERED SHOP DRAWINGS THE T.G.C. SHALL ENSURE THAT APPLICABLE SUBCONTRACTORS SUBMIT ENGINEERED SHOP DRAWINGS TO THE NEW STORE DEVELOPMENT FOR APPROVAL OF ALL ASSEMBLIES, TO OBTAIN BUILDING PERMITS, IF REQUIRED, AND LICENSES, OR FOR SUBSTITUTIONS, 16.0 CHANGE ORDERS THE T.G.C, MUST SUBMIT ALL CHANGE ORDERS IN WRITING TO THE NEW STORE DEVELOPMENT AND THE OWNER, THE OWNER MUST RECEIVE THE NEW STORE DEVELOPMENT DEPARTMENT'S PRELIMINARY APPROVAL BEFORE GIVING THE T.G,C, PERMISSION TO MOVE FORWARD WITH THE CHANGE ORDER, THE T.G.C, MUST HAVE THE OWNER'S SIGNATURE BEFORE PROCEEDING WITH THE WORK, SHOULD THE T.G.C. PROCEED WITH THE WORK PRIOR TO OBTAINING THE OWNER'S SIGNATURE ON THE CHANGE ORDER, THE T.G.C. WILL BE RESPONSIBLE FOR ALL COSTS ASSOCIATED WITH THE CHANGE ORDER. 17,0 TENANT T.G,C. RESPONSIBILITIES THE T.G,C,'S RESPONSIBILITIES TO INSTALL AND FURNISH MATERIAL/EQUIPMENT ARE LISTED FOR CLARIFICATION AND DO NOT RELIEVE THE T,G,C. OF THE RESPONSIBILITY TO COORDINATE THE MATERIAL/EQUIPMENT DELIVERY OF ALL SUBCONTRACTORS, ALL MATERIAL/EQUIPMENT ASSOCIATED WITH THIS PROJECT SHALL BE INSTALLED IN FULL ACCORDANCE WITH THE SUPPLIER'S AND/OR MANUFACTURER'S WRITTEN RECOMMENDATION, 18.0 PRODUCT SUBSTITUTIONS THE T.G.C, SHALL RECEIVE APPROVAL FROM NEW STORE DEVELOPMENT FOR ANY SUBSTITUTIONS TO ANY PRODUCT, TECHNIQUE, MATERIAL OR EQUIPMENT PRIOR TO THE IMPLEMENTATION OF THE SUBSTITUTION, PROPOSED SUBSTITUTION SHALL BE OF EQUAL QUALITY AND PERFORMANCE SPECIFICATION TO THAT ORIGINALLY SPECIFIED, 19.0 LANDLORD REQUIREMENTS ❑F BUILDING SYSTEMS T 19.1 ATTACHMENT UILDI 0 SLAB THE METHOD OF ATTACHMENT OF TENANT WORK TO THE BASE BUILDING STRUCTURE WILL BE IN ACCORDANCE WITH STANDARDS REQUIRED BY THE LANDLORD, THE T,G,C, WILL CONSULT THE LANDLORD IN THOSE MATTERS PRIOR TO ATTACHMENT OF SYSTEMS, 19.2 PLACEMENT OF EQUIPMENT ON ROOFt THE T,G,C, SHALL RESTRICT THE LOCATION OF ALL MECHANICAL EQUIPMENT ON THE ROOF TO MEET LOCAL CODE AND LANDLORD REQUIREMENTS, ANY CHANGES RELATED TO THE MOVING OF EQUIPMENT BECAUSE OF CODE VIOLATIONS OR IF PLACEMENT DOES NOT MEET MANUFACTURER'S REQUIREMENTS SHALL BE THE RESPONSIBILITY OF THE T,G,C, 19.3 ROOFING WORK, IT IS THE RESPONSIBILITY OF THE T.G,C. TO DETERMINE IF THE ROOF IS A BONDED ROOF. IF THE ROOF IS BONDED, THE T,G,C, SHALL BE RESPONSIBLE FOR COORDINATING ALL ROOFING WORK WITH LANDLORD'S DESIGNATED ROOFING CONTRACTOR. ANY ROOFING COSTS ASSOCIATED WITH THE PROJECT SHALL BE INCLUDED IN THE T.G.C,'S BID, THE ROOFING CONTRACTOR SHALL WARRANT ALL WORK PER THEIR STANDARD TERMS AND CONDITIONS TO THE LANDLORD. THE ROOFING CONTRACTOR SHALL WARRANT ALL ROOF WORK TO THE OWNER FOR A PERIOD OF ONE (1) YEAR FROM THE CERTIFICATE OF OCCUPANCY DATE. ANY WARRANTY PROBLEMS ASSOCIATED WITH THE ROOF SHALL BE COORDINATED THROUGH THE T.G,C. 20.0 WEATHER PROTECTION THE CONSTRUCTION SITE SHALL BE MAINTAINED IN A WEATHERPROOF CONDITION AT ALL TIMES, ANY WEATHER DAMAGE TO THE PROJECT WORK, BUILDING, CONSTRUCTION MATERIALS OR EQUIPMENT FROM WEATHER DURING THE CONSTRUCTION PROCESS SHALL BE THE SOLE RESPONSIBILITY OF THE T,G.C, 21.0 COORDINATION OF MATERIAL/EQUIPMENT DELIVERY NEW STORE DEVELOPMENT WILL SUPPLY THE T,G,C. WITH AN OWNER SUPPLIED EQUIPMENT DELIVERY SCHEDULE ONCE THE CONSTRUCTION CONTRACT HAS BEEN EXECUTED. THE T.G.C. SHALL SUBMIT FINAL DELIVERY DATES TO NEW STORE DEVELOPMENT WITHIN THREE (3) DAYS OF RECEIVING THE PR ELIMINARY DELIVERY SCHEDULE, THE T.G.C. SHALL BE RESP❑NSIBLE FOR NOTIFYING NEW STORE DEVELOPMENT IMMEDIATELY OF ANY DELAYS OF A WEEK OR MORE IN THE CONSTRUCTION SCHEDULE SO THAT THE DELIVERY SCHEDULE CAN BE ADJUSTED ACCORDINGLY, THE T.G.C, IS RESPONSIBLE FOR ALL ADDITIONAL COSTS ASSOCIATED WITH STORAGE AND DELIVERY IF THIS PROCEDURE IS NOT FOLLOWED. 22,0 RECEIPT OF MATERIAL/EQUIPMENT ALTHOUGH JMC RESTAURANT DISTRIBUTION WILL DO EVERYTHING POSSIBLE To HAVE MATERIAL/EQUIPMENT FOR THE PROJECT SHIPPED TO THE J❑BSITE ON TIME PER THE FINAL PUBLISHED CONSTRUCTION SCHEDULE, IT IS THE T,G,C. RESPONSIBILITY TO RECEIVE AND SIGN FOR A MATERIAL/EQUIPMENT T LLF❑R HE PROJECT AND PROJECT TEAM MEMBERS. UNDER NO CIRCUMSTANCES SHALL ANY SHIPMENT BE REFUSED FOR ANY REASON OTHER THAN DAMAGE, WHICH OCCURRED TO THE MATERIAL/EQUIPMENT DURING SHIPPING (PLEASE REFER SECTION 25.0, THE T,G,C. SHALL BE HELD ACCOUNTABLE TO CONFIRM THE ITEMS ON THE BILL OF LADING WHERE PRESENT IN THE SHIPMENT. ANY DISCREPANCIES SHALL BE NOTED AT THE TIME OF RECEIPT. ANY HEAVY EQUIPMENT RENTAL (I.E, FORKLIFTS, CRANES, ETC,) REQUIRED TO OFF-LOAD AN INCOMING TRUCK AND PLACE EQUIPMENT IN THE SECURED STORAGE AREA SHALL BE THE RESPONSIBILITY OF THE T.G.C. THE T.G.C. SHALL PAY FOR ANY CHARGES INCURRED BECAUSE SHIPMENTS ARE REFUSED. 23.0 EQUIPMENT STORAGE THE T.G.C. SHALL PROVIDE A STORAGE AREA THAT IS SECURED FROM THEFT, VANDALISM AND WEATHER DURING THE CONSTRUCTION PROCESS FOR ALL SUPPLIES AND EQUIPMENT. AT THE T.G.C.'S DISCRETION, THE T,G.C, MAY ELECT TO HAVE THE EQUIPMENT STORED AT THE TRUCKER'S FREIGHT TERMINAL OR OFF SITE AT THE T.G.C.'S OWN FACILITY, ANY CHARGES INCURRED RELATED TO THE STORAGE AND REDELIVERY OF THE EQUIPMENT SHALL BE THE SOLE RESPONSIBILITY OF THE T.G.C, UNDER NO CIRCUMSTANCES SHALL THE T,G,C, SURROGATE RESPONSIBILITY TO ANY SUBCONTRACTOR AND/OR TEAM MEMBER. 24.0 DAMAGED MATERIALS/EQUIPMENT 24.1 DAMAGED UPON DELIVERYi UPON DELIVERY OF MATERIALS/EQUIPMENT, IT IS THE RESPONSIBILITY OF THE T.G.C, TO THOROUGHLY INSPECT ALL MATERIALS/EQUIPMENT PRIOR TO ACCEPTING DELIVERY. SHOULD THE T.G.C, FIND ANY DAMAGE TO THE MATERIALS/EQUIPMENT CAUSED DURING SHIPMENT, THE T,G,C, SHALL REFUSE DELIVERY AND CONTACT JMC RESTAURANT DISTRIBUTION'S CUSTOMER SERVICE DEPARTMENT (972-389-2420) IMMEDIATELY, UNDER NO CIRCUMSTANCES SHALL THE T.G,C. SURROGATE THIS RESPONSIBILITY TO ANY SUBCONTRACTOR AND/OR TEAM MEMBER, (SEE ATTACHED APPENDIX 'A') 24.2 DAMAGE DURING THE CONSTRUCTION PROCESSi SHOULD ANY MATERIALS/EQUIPMENT BECOME DAMAGED DURING THE CONSTRUCTION PROCESS, THE T.G,C, SHALL CONTACT JMC RESTAURANT DISTRIBUTION IMMEDIATELY TO RECEIVE DIRECTION AS TO THE CORRECT REPAIR PROCESS. THE T.G,C, IS NOT TO PROCEED WITH REPAIRS TO MATERIALS/EQUIPMENT DAMAGED DURING THE CONSTRUCTION PROCESS WITH❑UT FIRST SPEAKING WITH A JMC RESTAURANT DISTRIBUTION CUSTOMER SERVICE REPRESENTATIVE, FREIGHT DAMAGE FOUND TWO OR MORE DAYS AFTER DELIVERY WILL BE DEEMED DAMAGE DURING CONSTRUCTION, THE T.G.C. WILL BE RESPONSIBLE FOR ALL REPAIR COSTS FOR ITEMS DAMAGED DURING CONSTRUCTION, UNDER NO CIRCUMSTANCES SHALL THE T,G.C. SURROGATE THIS RESPONSIBILITY To ANY SUBCONTRACTOR AND/OR TEAM MEMBER, 24.3 DAMAGED HVAC EQUIPMENTi UPON DELIVERY OF MATERIALS/EQUIPMENT, IT IS THE RESPONSIBILITY OF THE T.G.C, TO THOROUGHLY INSPECT ALL MATERIALS/EQUIPMENT PRIOR TO ACCEPTING DELIVERY. SHOULD THE T,G.C, FIND ANY DAMAGE TO THE MATERIALS/EQUIPMENT CAUSED DURING SHIPPING, THE T,G.C. SHALL NOTE ALL DAMAGE ON THE BILL OF LADING, ACCEPT DELIVERY AND CONTACT THE CICI'S PIZZA LENNOX REPRESENTATIVE IMMEDIATELY, THE T.G.C. SHALL ALSO FAX A COPY OF THE DETAILED BILL OF LADING TO THE CICI'S PIZZA TRANE REPRESENTATIVE. UNDER NO CIRCUMSTANCES SHALL THE T.G.C. SURROGATE THIS RESPONSIBILITY TO ANY SUBCONTRACTOR AND/OR TEAM MEMBER, 25.0 EARLY DELIVERY OF EQUIPMENT EQUIPMENT WILL BE ORDERED TO DELIVER ON SCHEDULED DATES (PLUS OR MINUS ABOUT FOUR (4) DAYS, THE T.G.C, SHOULD CALL A JMC RESTAURANT DISTRIBUTION'S CUSTOMER SERVICE REPRESENTATIVE FOR DISPOSITION ON ANY ITEM ATTEMPTING TO BE DELIVERED PRIOR TO THIS TIME THAT THEY DEEM A PROBLEM. TABLE OF CONTENTS GENERAL CONDITIONS 01010 FORMAT AND CONTENT 01014 CONTRACTOR'S USE OF SITE AND PREMISE 01015 OWNER FURNISHED ITEMS 01017 WORK BY OTHERS 01500 TEMPORARY FACILITIES 01600 MATERIALS AND WORKMANSHIP 01630 SUBSTITUTIONS 01710 FINAL CLEANING 10730 OPERATION AND MAINTENANCE DATA 10740 WARRANTY 10760 CONTRACT CLOSEOUT DIVISION 2 SITE WORK (NOT USED) DIVISION 3 - CONCRETE (NOT USED) DIVISION 4 - MASONRY (NOT USED) DIVISION 5 - METALS 05400 STEEL STUD FRAMING DIVISION 6 - CARPENTRY 06200 FINISH CARPENTRY DIVISION 7 - MOISTURE PROTECTION 07200 BUILDING INSULATION 07900 CAULKING AND SEALANTS 08100 STEEL DOORS AND FRAMES 08250 FLUSH WOOD DOORS 08400 ALUMINUM FRAMING 08700 FINISH HARDWARE DIVISION 9 - FINISHES GYPSUM WALLBOARD 09250 09300 TILE 09500 LAY -IN CEILINGS 09900 PAINTING DIVISION 10 - SPECIALTIES EXTERIOR SIGNAGE 10430 10440 INTERIOR SIGNAGE 10520 FIRE EXTINGUISHERS 10800 TOILET ACCESSORIES DIVISION it - EQUIPMENT FOOD SERVICE EQUIPMENT 11400 15000 HEATING, VENTILATING AND AIR CONDITIONING 15001 PLUMBING LION 16 - ELECTRICAL GENERAL CONDITIONS BASIC DEFINITIONS, THE CONTRACT DOCUMENTS ARE ALL THE DOCUMENTS REQUIRED FOR THE GENERAL CONTRACTOR TO SUCCESSFULLY COMPLETE THE WORK, AND INCLUDE NOT ONLY THE ARCHITECT'S DRAWINGS AND THE ARCHITECTS SPECIFICATIONS BUT ALSO DRAWINGS, SPECIFICATIONS AND OTHER DOCUMENTS NOT LISTED HERE, WHICH HAVE BEEN OR WILL BE PREPARED BY CONSULTANTS, MANUFACTURERS, SUPPLIERS, VENDORS AND OTHERS FOR THE OWNER, DRAWINGS AND SPECIFICATIONS UNLESS SPECIFICALLY NOTED OTHERWISE ANY REFERENCE TO THE DRAWINGS OR SPECIFICATIONS SHALL MEAN THE DRAWINGS AND SPECIFICATIONS PREAPRED BY THE ARCHITECT. CONFLICTS, DISCREPANCIES OR INCONSISTENCIESi IN THE EVENT OF CONFLICTS DISCREPANCIES OR INCONSISTENCIES AMONG E ES CONTRACT DOCUMENTS, INTERPRETATIONS WILL BE MADE BY THE ARCHITECT BASED ON THE FOLLOWING, IN ORDER OF PRIORITY, WITH ITEM 1 BEING ❑FFIRST, OR HIGHEST PRIORITYt 1. AGREEMENT BETWEEN THE OWNER AND GENERAL CONTRACTOR. 2. ADDENDA TO THE DRAWINGS AND SPECIFICATIONS, WITH THOSE LATER DATE HAVING PRECEDENCE OVER THOSE OF EARLIER DATE 3. DRAWINGS AND SPECIFICATIONS, IN THE EVENT OF CONFLICTS, A. WHERE NOT CLARIFIED BY THE AGREEMENT OR ADDENDA TO THE DRAWINGS AND SPECIFICATIONS, THE BETTER QUALITY OR GREATER QUANTITY OF WORK SHALL BE PROVIDED AS REQUIRED BY EITHER THE DRAWINGS OR SPECIFICATIONS IN ACCORDANCE WITH THE ARCHITECT'S INTERPRETATION. B. AS BETWEEN DIMENSIONS SHOWN ON THE DRAWINGS AND SCALED MEASUREMENTS, THE DIMENSIONS SHALL GOVERN, C. AS BETWEEN LARGE-SCALE DRAWINGS AND SMALL -SCALED DRAWINGS, THE LARGER SCALE SHALL GOVERN, D. MATERIALS AND EQUIPMENT SHALL BE INSTALLED IN STRICT COMPLIANCE WITH THE MOST CURRENT PRINTED OR PUBLISHED SPECIFICATIONS AND INSTRUCTIONS OF THE MANUFACTURER OR SUPPLIER OF THE MATERIAL OR EQUIPMENT, EXCEPT WHERE SUCH DOCUMENTS CONFLICT WITH THE ARCHITECT'S SPECIFICATIONS) IN SUCH CASES THE BETTER QUALITY OR GREATER QUANTITY OF WORK SHALL BE PROVIDED IN ACCORDANCE WITH THE ARCHITECT'S INTERPRETATION AS REQUIRED BY EITHER (1) THE MANUFACTURER'S OR SUPPLIER'S REQUIREMENTS OR (2) THE ARCHITECT'S SPECIFICATIONS, PRODUCT DESIGNATIONS WHEN REFERENCE IS MADE TO TRADE NAMES OR TO THE NAMES OF MANUFACTURERS, SUCH REFERENCES ARE MADE SOLELY TO DESIGNATE OR IDENTIFY THE QUALITY OF MATERIAL OR EQUIPMENT TO BE FURNISHED AND ARE INTENDED TO RESTRICT THE USE OF EQUAL MATERIAL OR EQUIPMENT EXCEPT WHERE SPECIFICALLY STATED OTHERWISE, IF THE CONTRACTOR WISHED TO USE MATERIALS AND EQUIPMENT OTHER THEN THOSE MENTIONED IN THE SPECIFICATIONS, THE CONTRACTOR SHALL SUBMIT IN WRITING AND INCLUDING ADEQUATE INFORMATION REGARDING THE SUBSTITUTION, TO REVIEW OF CONTRACT DOCUMENTS AND FIELD CONDITIONS BY CONTRACTORBEFORE ORDERING ANY MATERIALS OR ANY WORK, THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND MEASUREMENTS AND SHALL BE RESPONSIBLE FOR CORRECTNESS OF SAME. NO EXTRA CHARGE OR COMPENSATION WILL BE ALLOWED BECAUSE OF DIFFERENCES BETWEEN ACTUAL DIMENSIONS AND MEASUREMENTS AND THOSE INDICATED ON THE DRAWINGS AND DIFFERENCES WHICH MAY BE FOUND SHALL BE SUBMITTED TO THE ARCHITECT FOR CONSIDERATION BEFORE PROCEEDING WITH THE WORK, THIS APPLIES TO ALL ASPECTS OF THE WORK INCLUDING, BUT NOT LIMITED TO, EQUIPMENT OR MATERIALS FURNISHED BY OWNER OR CONTRACTOR. PERMIT FEES AND NOTICES UNLESS OTHERWISE PROVIDED IN THE CONTRACT DOCUMENTS, THE CONTRACTOR SHALL SECURE AND PAY FOR THE REMOVAL, RELOCATION AND INSTALLATION OF ELECTRICAL UTILITY POLES AND LINES AND FOR WATER, NATURAL GAS AND SEWER SUBCONTRACTOR RELATIONSTHE CONTRACTOR SHALL INCLUDE IN HIS SUBCONTRACTS THE FOLLOWING CLAUSE, BY EXECUTING THE CONTRACT BETWEEN THE GENERAL CONTRACTOR AND THE SUBCONTRACTOR EACH SUBCONTRACTOR REPRESENTS THAT HE HAS MORE CURRENT AND INTIMATE KNOWLEDGE OF PREVAILING CODES IN HIS SPECIAL FIELD THAN D❑ GENERALIST. THE SUBCONTRACTOR AGREES TO REPORT TO THE GENERAL CONTRACTOR AS EARLY IN THE PROJECT AS POSSIBLE (PRIOR TO SIGNING THE CONTRACTOR/SUBCONTRACTOR CONTRACT IF KNOWN AT THE TIME BUT IN ANY EVENT AS SOON AS KNOWN) ANY WORK REQUIRED BY THE DRAWINGS AND SPECIFICATIONS, OR ANY OF THE OTHER CONTRACT DOCUMENTS WHICH VIOLATES ANY CODE AFFECTING OR CONTROLLING THE SUBCONTRACTOR'S SPECIALTY, THE CONTRACTOR SHALL IN TURN IMMEDIATELY CONVEY THIS INFORMATION ❑T THE ARCHITECT, DIVISION 1 - GENERAL REQUIREMENTS SECTION 01010 FORMAT AND CONTENT THE SPECIFICATIONS HAVE BEEN PREPARED FOR MULTIPLE PROJECTS AND SECTION 01010 MAY CONTAIN REFERENCES TO ITEMS NOT INCLUDED IN THIS SPECIFIC PROJECT. VERIFY ITEMS USED IN THIS SPECIFIC PROJECT BY REFERRING TO THE DRAWINGS. THE SPECIFICATIONS MAY MAKE REFERENCE TO THESE ITEMS BY STATING • IF REQUIRED PER DRAWINGS• • IF ANY' OR SIMILAR LANGUAGE, THE DRAWINGS ARE SCHEMATIC IN NATURE AND THE CONTRACTOR SHALL NOT RELY ON SCALING DRAWINGS TO DETERMINE CRITICAL DISTANCES. WHERE CONTRACT DOCUMENTS (DRAWINGS AND SPECIFICATIONS) ARE INCOMPLETE, AMBIGUOUS OR CONTAIN CONFLICTING INSTRUCTIONS, DO NOT PROCEED UNTIL RECEIVING CLARIFICATION FROM THE ARCHITECT IN WRITING. CONTRACTOR'S USE OF SITE AND PREMISE, SECTION 01014 CONTRACTOR'S USE OF SITE AND PREMISE LIMITED USE OF THE SITE, VERIFY WITH THE OWNER OR LANDLORD FOR ESTABLISHED USE LIMITS AND RESTRICTIONS OF THE SITE, D❑ NOT COMMENCE WORK WHICH SPECIFICALLY AFFECTS THE OPERATION OF ANY OTHER TENANT WITHOUT FIRST COORDINATING AND MAKING SATISFACTORY ARRANGEMENTS FOR SUCH WORK THROUGH THE OWNER OR LANDLORD, OWNER -FURNISHED ITEMS SECTION 01015 OWNER FURNISHED ITEMS CERTAIN CONSTRUCTION AND EQUIPMENT ITEMS INDICATED IN THE DRAWINGS AND SPECIFICATIONS MAY BE FURNISHED BY THE OWNER. SUCH ITEMS ARE DESIGNATED ON THE DRAWINGS IN THE 'EQUIPMENT SCHEDULE' OR ELSEWHERE AS SUPPLIED BY OWNER OR VENDOR, UNLESS SPECIFICALLY OTHERWISE INDICATED, OWNER WILL DELIVER SUCH ITEMS TO THE CONTRACTOR WHO SHALL BE RESPONSIBLE FOR RECEIVING, UNLOADING, INVENTORYING, WAREHOUSING, PROTECTING, INSURING, ASSEMBLING AND INSTALLING THEM IN THE SAME MANNER AS IF PURCHASED DIRECTLY BY THE CONTRACTOR, WORK BY OTHERS SECTION 01017 WORK BY OTHERS CERTAIN ITEMS INDICATED IN THE DRAWINGS AND SPECIFICATIONS MAY BE FURNISHED AND INSTALLED BY ENTITIES OTHER THAN THE CONTRACTOR AND SECTION 01500 ARE EXCLUDED FORM THE CONTRACT TO BUILD. SUCH ITEMS (IF ANY) ARE INDICATE IN 'EQUIPMENT SCHEDULE' OR ELSEWHERE ON THE DRAWINGS. CONTRACTOR SHALL INDICATE SEPARATE INSTALLATION COST FOR ITEMS DESIGNATED IN 'EQUIPMENT SCHEDULE ' TO BE FURNISHED BY OWNER OR 'OTHERS', SECTION 01500 TEMPORARY FACILITIES THE CONTRACTOR IS RESPONSIBLE FOR ARRANGING AND PAYING FOR ALL UTILITIES INCLUDING PHONE AND SANITATION SERVICE NECESSARY TO CONSTRUCT THE PROJECT. THE CONTRACTOR IS RESP❑NSIBLE FOR THE PROTECTION AND SECURITY OF ALL CONSTRUCTION AND ALL BUILDING MATERIALS AND EQUIPMENT AND SHALL FURNISH AT HIS EXPENSE ON -SITE STORAGE EQUIVALENT TO AN 8 FOOT BY 8 FOOT BY 40 FOOT, LOCKABLE, WEATHER TIGHT TRAILER THROUGHOUT THE CONSTRUCTION UNLESS MATERIALS AND WORKMANSHIP OTHERWISE INDICATED. SECTION 01600 MATERIALS AND WORKMANSHIP ENTITIES PERFORMING WORK SHALL BE SKILLED AND KNOWLEDGEABLE IN METHODS AND CRAFTSMANSHIP NEEDED TO PRODUCE REQUIRED QUALITY LEVELS. REMOVE AND REPLACE WORK, WHICH DOES NOT COMPLY, WITH WORKMANSHIP STANDARDS SPECIFIED AND AS RECOGNIZED IN THE CONSTRUCTION INDUSTRY FOR APPLICATIONS INTENDED, INSTALLER OF EACH MAJOR UNIT OF WORK SHALL INSPECT SUBSTRATA TO RECEIVE WORK AND CONDITIONS UNDER WHICH WORK IS TO BE PERFORMED, DO NOT PROCEED WITH WORK UNTIL UNSATISFACTORY CONDITIONS HAVE BEEN CORRECTED. HANDLE, STORE, INSTALL, MAINTAIN AND OTHERWISE USE PRODUCTS IN COMPLIANCE WITH MANUFACTURER'S APPLICABLE I ABLE INSTRUCTIONS AND RECOMMENDATIONS AND IN A MANNER TO ENSURE BEST POSSIBLE RESULTS, PROVIDE ATTACHMENT AND CONNECTION DEVICES AND METHODS FOR SECURING WORK PROPERLY, TRUE TO LINE AND LEVEL AND WITHIN RECOGNIZED INDUSTRY TOLERANCES IF NOT OTHERWISE INDICATED. ALLOW FOR EXPANSION, CONTRACTION AND OTHER NORMAL BUILDING MOVEMENTS, PROTECT AND MAINTAIN WORK TO ENSURE FREEDOM FROM DAMAGE OR DETERIORATION AT TIME OF COMPLETION. PERMANENTLY ISOLATE EACH UNIT OF WORK FROM NON -COMPATIBLE WORK TO PREVENT DETERIORATION, FIELD CHECK AND VERIFY AS -BUILT DIMENSIONS TO ASSURE PROPER FIT OF PREFABRICATED MATERIALS AND EQUIPMENT, INSTALL WORK DURING OPTIMUM WEATHER CONDITIONS OF TEMPERATURE, HUMIDITY, FORECASTED WEATHER, ETC„ TO ENSURE BEST POSSIBLE RESULTS, EXCEPT FOR REQUIRED LABELS AND OPERATING DATA, D❑ NOT PERMANENTLY ATTACH OR IMPRINT MANUFACTURER'S NAMEPLATES OR TRADEMARKS ON EXPOSED SURFACES OR PRODUCTS WHICH WILL BE EXPOSED TO VIEW IN OCCUPIED SPACES OR ON THE EXTERIOR. ADJUST ALL MOVING PARTS AND VARIABLES TO OPTIMUM SETTINGS, SUBSTITUTIONS SECTION 01630 SUBSTITUTIONS NO SUBSTITUTIONS FOR PRODUCTS WILL BE ALLOWED UNLESS SPECIFICALLY INDICATED BY THE ARCHITECT, SUBSTITUTION FOR PRODUCTS AND EQUIPMENT MAY BE CONSIDERED WHEN A PRODUCT BECOMES UNAVAILABLE THROUGH NO FAULT OF THE CONTRACTOR OR AS FOLLOWSt 1, AN 'OR OWNER APPROVED SUBSTITUTION' CLAUSE OR SIMILAR LANGUAGE IN THE CONTRACT DOCUMENTS, 2. WHEN THE PRODUCT CANNOT BE PROVIDED IN TIME TO KEEP THE PROJECT ON SCHEDULE, THROUGH NO FAULT OF THE CONTRACTOR. 3. WHEN THE PRODUCT DOES NOT MEET THE APPROVAL OF THE GOVERNING AUTHORITIES. 4, WHEN THE OWNER IS OFFERED SUBSTANTIAL ADVANTAGE IN TERMS OF COST, TIME OR QUALITY, WHENEVER A PRODUCT IS SPECIFIED BY USING A PROPRIETARY NAME OR THE NAME OF A PARTICULAR MANUFACTURER OR VENDOR, THE SPECIFIC ITEM MENTIONED SHALL BE UNDERSTOOD AS ESTABLISHING TYPE, FUNCTION, DIMENSION, APPEARANCE AND QUALITY DESIRED. REQUESTS FOR SUBSTITUTING OTHER MANUFACTURER'S PRODUCTS MAY BE ACCEPTED PROVIDED SUFFICIENT INFORMATION IS SUBMITTED TO ALLOW THE OWNER TO DETERMINE SUITABILITY OF THE PROPOSED SUBSTITUTION(S) AND AS FOLL❑WSJ 1, PRODUCT APPROVAL, IF A QUALIFIED BIDDER PROPOSES TO FURNISH MATERIALS, PRODUCTS OR EQUIPMENT NOT SPECIFIED, BIDDER MUST RECEIVE PRIOR WRITTEN APPROVAL THRU AN ADDENDUM ISSUED BY THE OWNER OR ARCHITECT AND SHALL SUBMIT MANUFACTURER'S NAME AND CATALOG INFORMATION NO LATER THAN SEVEN (7) WORKING DAYS PRIOR TO THE BIDDING OF THE PROJECT, UNLESS SPECIFICALLY OTHERWISE INDICATED BY THE CONSTRUCTION MANAGER, THE OWNER (UPON EXAMINATION OF DATA, SAMPLES, ETC,) WILL INSTRUCT THE ARCHITECT TO ISSUE AN ADDENDUM TO THE DRAWINGS AND SPECIFICATION. IF NO ADDENDUM IS ISSUED, IT IS UNDERSTOOD THAT THE BIDDER SHALL SUPPLY MATERIALS, PRODUCTS AND EQUIPMENT EXACTLY AS SPECIFIED, c E c , rn y 8 , N v N 0 04 o � U ' JLL o a o 14 00 CD C N Q 0 o a 0 JM M J 0 La U�a M o0 00 o 0 z o > $ N J oC Q Qi v vi c _1 n 1 J LL o� U O 0 0 0 N J Nt Q Mw 0 UJ J J z N Q=LL O E m J a �J= w U �Q� V' _ Q V LJJ oo L li N(0N Revisions: CD Z 060 U)Q FU o U_ ZU a. CD Project Number 07059 Date 02-28-08 Sheet Number G1.2 SECTION 01710 FINAL CLEANING EXECUTE FINAL CLEANING PRIOR TO FINAL INSPECTION. THOROUGHLY CLEAN THE PROJECT INCLUDING (BUT NOT NECESSARILY LIMITED T❑) THE FOLLOWING! A. REMOVE LABELS, WHICH ARE NOT REQUIRED AS PERMANENT LABELS. B. CLEAN TRANSPARENT MATERIALS, INCLUDING MIRRORS, WINDOW AND DOOR GLASS, TO A POLISHED CONDITION, REMOVING SUBSTANCES, WHICH ARE NOTICEABLE AS VISI❑N-OBSCURING MATERIALS, REPLACE BROKEN AND DAMAGED GLASS AND DAMAGED TRANSPARENT MATERIALS, C. CLEAN EXPOSED EXTERIOR AND INTERIOR HARD -SURFACED FINISHES, TO A DIRT -FREE CONDITION, FREE OF DUST, STAINS, FILMS AND SIMILAR NOTICEABLE DISTRACTING SUBSTANCES, EXCEPT OTHERWISE INDICATED, AVOID DISTURBANCE OF NATURAL WEATHERING OF EXTERIOR SURFACES, RESTORE REFLECTIVE SURFACES TO ORIGINAL REFLECTIVE CONDITION. D. WIPE SURFACES OR MECHANICAL AND ELECTRICAL EQUIPMENT CLEAN. REMOVE EXCESS LUBRICATION AND OTHER SUBSTANCES. E. REMOVE DEBRIS AND SURFACE DUST FROM LIMITED -ACCESS SPACES INCLUDING PLENUMS, SHAFTS, TRENCHES, MANHOLES, ATTICS AND SIMILAR SPACES. F. THOROUGHLY CLEAN CONCRETE FLOORS, G. VACUUM CLEAN CARPETED SURFACES AND SIMILAR SOFT SURFACES. H, CLEAN PLUMBING FIXTURES TO A SANITARY CONDITION, FREE OF STAINS INCLUDING THOSE RESULTING FROM WATER EXPOSURE, I. CLEAN FOOD SERVICE EQUIPMENT TO A CONDITION OF SANITATION READY AND ACCEPTABLE FOR INTENDED FOOD SERVICE USE, J. CLEAN LIGHT FIXTURES AND LAMPS/LIGHT BULBS, WHICH HAVE BURNED HALF THEIR RATED LIFE OR MORE, K. CLEAN PROJECT SITE (YARD AND GROUNDS), INCLUDING LANDSCAPE DEVELOPMENT AREAS, OF LITTER AND FOREIGN SUBSTANCES. SWEEP PAVED AREAS TO A BROOM -CLEAN CONDITION, REMOVE STAINS, PETROCHEMICAL SPILLS AND OTHER FOREIGN DEPOSITS, RAKE GROUNDS WHICH ARE NEITHER PLANTED NOR PAVED, TO A SMOOTH, EVEN -TEXTURED SURFACE, L. CLEAN FILTERS OF OPERATING EQUIPMENT, M. PROPERLY CLEAN AND SANITIZE FOOD CONTACT SURFACES BEFORE SERVICE USAGE, N. CLEAN DEBRIS FROM ROOF, GUTTERS, DOWNSPOUTS AND DRAINAGE SYSTEMS, 0, REMOVE WASTE AND SURPLUS MATERIAL, RUBBISH AND CONSTRUCTION FACILITIES FROM THE SITE, SECTION 01740 WARRANTY CONTRACTOR SHALL WARRANT ❑T THE OWNER THAT ON RECEIPT OF NOTICE FROM HIM, WITHIN A PERIOD OF ONE YEAR (OR SUCH OTHER PERIOD OF TIME AS MAY BE NOTED FOR SPECIFIC ITEMS) FOLLOWING DATE OF SUBSTANTIAL COMPLETION, THE CONTRACTOR SHALL, AT HIS COST, WARRANTY.ANY DEFECTS IN MATERIALS AND WORKMANSHIP THAT HAVE APPEARED IN THE WORK SO THAT THEY MEET THE CONDITIONS ORIGINALLY REQUIRED BY THE CONTRACT DOCUMENTS, PREPARE DUPLICATE NOTARIZED COPIES OF ALL WARRANTIES. EXECUTE AND ASSEMBLE DOCUMENTS FROM SUBCONTRACTORS, SUPPLIERS AND MANUFACTURERS, RETAIN ALL DOCUMENTS IN THE OPERATION AND MAINTENANCE INSTRUCTIONS MANUAL NOTED IN SECTION 01730 AT THE JOB SITE UPON COMPLETION OF THE WORK, SECTION 01760 CONTRACT CLOSEOUT 1,01 FINAL WORK AT COMPLETION OF THE WORK, LEAVE THE BUILDING COMPLETELY CLEAN AND IN CONDITION SATISFACTORY ❑T THE OWNER. CLEAN AND POLISH ALL GLASS AND MIRRORS, LEAVE FLOORS, HARDWARE, PLUMBING FIXTURES AND LIGHTING FIXTURES CLEAN AND DUST FREE, ETC,, THIS IS NOT AN ENUMERATION OF WORK TO BE DONE, BUT IS MERELY AN INDICATION OF WHAT WILL BE CONSIDERED 'SATISFACTORY' 1.02 BONDS, GUARANTEES AND WARRANTIES A. THROUGHOUT THE SPECIFICATIONS VARIOUS SURETY BONDS, GUARANTEES AND WARRANTIES ARE REQUIRED. THE CONTRACTOR SHALL SECURE AND PRESENT THESE BONDS AND GUARANTEES TO THE OWNER, B. THE CONTRACTOR SHALL PRESENT THE OWNER WITH ALL OPERATING MANUALS, MANUALS, PARTS LIST, ETC„ COVERING ALL MECHANICAL EQUIPMENT OR OTHER OPERATING DEVICES IN THE WORK. C. THE CONTRACTOR SHALL PRESENT THE OWNER WITH ALL SPECIAL TOOLS REQUIRED FOR ROUTINE MAINTENANCE OF EQUIPMENT, ETC, 1.03 RECORD DRAWINGS THE CONTRACTOR SHALL PRESENT THE OWNER WITH A COPY OF RECORD DRAWINGS, DIVISION 2 - SITE WORK (NOT USED) DIVISION 3 - CONCRETE (NOT USED) DIVISION 4- MASONRY (NOT USED) DIVISION 5 - METALS SECTION 05400 STEEL STUD FRAMING PART ONE - GENERAL 1,01 SCOPE FURNISH AND INSTALL STEEL STUDS, OTHER STEEL FRAMING MEMBERS, BRACING, FASTENERS AND OTHER RELATED ACCESSORIES IN LOCATIONS RELATED HERE IN AND SHOWN ON THE DRAWINGS, PART TWO - PRODUCTS 2.01 STEEL STUD FRAMING MATERIALS COLD FORMED STEEL FRAMING AS MANUFACTURED BY U.S,G. USING HOT DIPPED GALVANIZED STEEL WITH MINIMUM G-60 COATING WHICH CONFORMS TO ASTM SPECIFICATION A-446 AND A-525, LATEST EDITION, UNLESS NOTED OTHERWISE ON THE DRAWINGS, PRODUCT SHALL BE, 1. EQUAL TO U,S.G. SJ STEEL STUDS, 3 5/8, 25 GAUGE, SPACED 16' ON CENTERS. 2, RUNNER CHANNELS AT TOP AND BOTTOM OF STUDS SHALL BE OF SAME, SIZE AND GAUGE AS STUDS, B. MISCELLANEOUS COMPONENTS, PROVIDE ALL NECESSARY COMPONENT PARTS AND FASTENERS REQUIRED. FINISH TO HOT DIPPED GALVANIZED AS PECIFIED FOR STUDS OR STAINLESS STEEL, 2.02 ISOLATION JOINTS WHERE ALUMINUM OR OTHER DISSIMILAR MATERIALS COME IN CONTACT WITH STEEL FRAMING, FURNISH AND INSTALL PLASTIC ISOLATION BLOCKS (SHIMS) OR BUILDING FELT BETWEEN DISSIMILAR MATERIALS, PART THREE - EXECUTION 3.01 INSTALLATION INSTALL STEEL FRAMING TRUE TO LINE, LEVEL AND PLUMB, IN ACCORDANCE WITH THE DRAWINGS, AND APPROVED SHOP DRAWINGS AND THE MANUFACTURER'S WRITTEN INSTRUCTIONS. 3.02 FIELD PAINTING TOUCHUP GALVANIZED COATINGS DAMAGED DURING HANDLING AND INSTALLATION WITH GALVANIZING REPAIR PAINT, DIVISION 6 - CARPENTRY SECTION 06200 FINISH CARPENTRY PART ONE - GENERAL 1,01 SCOPE A. THIS SECTION INCLUDES FURNISHING AND INSTALLING ALL MISCELLANE❑US EXPOSED WOOD MEMBERS AND TRIM ITEMS AND SERVING COUNTER, AS DETAILED ON THE DRAWINGS, B. THIS SECTION INCLUDES INSTALLATION OF METAL FRAMES, WOOD DOORS, FINISH HARDWARE, AND MISCELLANEOUS METALS AND SPECIALTIES FURNISHED UNDER OTHER SECTIONS OF THESE SPECIFICATIONS, AND RELATED ITEMS NECESSARY FOR A COMPLETE AND PROPER INSTALLATION. PART TWO - MATERIALS 2.01 GENERAL REQUIREMENTS A. RECEIVE, STOCK AND STORE MATERIALS IN ACCORDANCE WITH GOOD PRACTICE, B. GRADING, EACH PIECE OF FINISH LUMBER SHALL BE GRADE - MARKED AND KILN -DRIED. BUNDLED STOCK SHALL HAVE GRADE MARKS APPLIED TO EACH BUNDLE. C. SIZES AND PATTERNSt WORK LUMBER TO PATTERN DETAILED. SHAPED MATERIAL SHALL CONFORM TO STANDARD PATTERNS INDICATED, D. M❑ISTURE CONTENTi MAXIMUM MOISTURE CONTENT OF TREATED OR UNTREATED FINISH LUMBER, TRIM AND MILLWORK SHALL BE 12 PERCENT AT TIME OF DELIVERY TO JOB SITE. 2.02 ROUGH HARDWARE THE GENERAL CONTRACTOR SHALL FURNISH ALL ROUGH HARDWARE, INCLUDING NAILS, SCREWS AND SIMILAR ANCHORS AND FITTINGS AND ALL OTHER HARDWARE EITHER MENTIONED IN THESE SPECIFICATIONS OR REQUIRED FOR THE PROPER COMPLETION OF THE WORK, 2.03 PLASTIC LAMINATE AS SCHEDULED ON THE DRAWINGS, COLORS AS SCHEDULED. 2.04 PLYWOOD VENEER CORE PLYWOOD OF THICKNESS SHOWN ON THE DRAWINGS, A. WHERE BOTH SIDES COVERED WITH PLASTIC LAMINATEi APA C-D INT, B. WHERE BOTH SIDES VISIBLEt APA B-B INT. C. WHERE BOTH SIDES VISIBLEi APA B-C OR B-D INT. D. COUNTERTOP AT SERVING COUNTERi APA B-B, EXPOSURE I. 2.05 FRP (FIBERGLASS REINFORCED POLYESTER) PANELS 3/32' THICK WITH PEBBLED TEXTURE FACE, COLOR NOTED ON THE DRAWINGS, BY MARLITE. INSTALL ON FACE OF GYPSUM BOARD OR PLYWOOD USING MARLITE CAULKING, C-375 ADHESIVE, AND MATCHING FP100 PVC MOLDINGS OF THE PROPER SHAPE AT EDGES, INTERIOR AND EXTERIOR CORNERS, BETWEEN PANELS, ALL IN STRICT ACCORDANCE WITH MARLITE COMPANY SPECIFICATIONS, 2.06 ADHESIVE FOR ADHERING PLASTIC LAMINATE TO PLYWOOD SUBSTRATE ON WALLS AND CABINETS, USE CONTACT ADHESIVE EQUAL TO WILSONART BRUSHABLE GRADE LW500 ON PLYWOOD AND PLASTIC LAMINATE SURFACES IN ACCORDANCE WITH ADHESIVE MANUFACTURER'S INSTRUCTIONS. FOR ADHERING SOLID SURFACING, BED THE SOLID SURFACE IN SILICONE SEALANT AS RECOMMENDED BY SOLID SURFACE MANUFACTURER ON THE WOOD/PLYWOOD FRAMING. PART THREE - EXECUTION 3,01 INSTALLATION A. INSTALL WORK OF THIS SECTION AS INDICATED ON THE DRAWINGS AND SPECIFIED HEREIN, IN ACCORDANCE WITH APPROVED SHOP DRAWINGS AND MANUFACTURER'S WRITTEN INSTRUCTIONS, B. INSTALL THE WORK PLUMB, TRUE AND STRAIGHT WITH NO DISTORTIONS. SHIM AS REQUIRED USING CONCEALED SHIMS, INSTALL TO A TOLERANCE OF 1/8' IN 8'-0' FOR PLUMB AND LEVEL (INCLUDING COUNTERTOPS) AND WITH 1/16' MAXIMUM OFFSET IN FLUSH ADJOINING SURFACES, 1/8' MAXIMUM OFFSETS IN REVEALED ADJOINING SURFACES, 3.02 FINISH HARDWARE RECEIVE, STORE AND INSTALL FINISH HARDWARE SPECIFIED ON THE DRAWINGS, AT COMPLETION OF THE JOB, CHECK AND LEAVE ALL HARDWARE IN OPTIMUM OPERATING CONDITION. TAG KEYS WITH HARD FIBER OR METAL EDGED CARDBOARD TAGS LABELED ACCORDING TO THE DOORS AS NUMBERED ON THE DRAWINGS, BOX KEYS NEATLY AND ORDERLY AND THEN TURN OVER TO THE OWNER, DIVISION 7 - M❑ISTURE PROTECTION SECTION 07200 BUILDING INSULATION PART ONE - GENERAL 1,01 SCOPE THE WORK OF THIS SECTION INCLUDES INSULATION AT EXTERIOR WALLS AND ELSEWHERE AS SHOWN ON THE DRAWINGS. PART TWO - MATERIALS 2.01 THERMAL INSULATION INORGANIC GLASS FIBER BLANKETS WITH VAPOR BARRIER, 6' THICK, R-19. PART THREE - EXECUTION 3,01 INSTALL THERMAL INSULATION ON TOP OF SUSPENDED CEILING TILES IN ATTIC SPACE AND IN WALL VOIDS OF EXTERIOR WALLS UNLESS NOTED OTHERWISE IN DRAWINGS. INSTALL ON OUTSIDE OF WATER PIPES IN EXTERIOR WALL, SECTION 07900 CAULKING AND SEALANTS PART ONE - GENERAL 1,01 SCOPE THE WORK OF THIS SECTION INCLUDES ALL SEALANTS AND CAULKING, BOTH INTERIOR AND EXTERIOR, PART TWO - MATERIALS 2.01 CAULKING POLYSULFIDE (THLOKAL) BASE CAULKING COMPOUND, SYNTHACAULK GC9 BY PECORA, OR APPROVED EQUAL. COLORS SHALL REASONABLY MATCH THAT OF ADJOINING WORK, PART THREE - EXECUTION 3.01 JOB CONDITIONS APPLY MATERIALS ONLY WHEN THE TEMPERATURE OF SPACES, MATERIALS, AND SURFACES IS ABOVE 40 DEGREES F, USE MATERIALS WITHIN THE MANUFACTURER'S RECOMMENDED SHELF -LIFE PRIORI REMOVE FROM THE JOB ANY MATERIALS WHOSE SHELF -LIFE PERIOD EXPIRES AFTER BEING BROUGHT TO THE JOB, AND REPLACE WITH FRESH MATERIAL, 3,02 APPLICATION A. APPLY CAULKING IN ACCORDANCE WITH MANUFACTURER'S WRITTEN INSTRUCTIONSi USING PRESSURE TYPE CAULK GUN, PRIME SIDES OF JOINTS BEFORE APPLYING CAULKING IF RECOMMENDED BY THE MANUFACTURER, WIDTH AND DEPTH OF SEALANT IN JOINTS SHALL BE MINIMUM 1/8', IN LARGE JOINTS, THE DEPTH OF SEALANT SHALL BE ONE HALF THE WIDTH OF THE JOINT, IF REQUIRED, PACK SPACES WITH COMPRESSIBLE MATERIALS, COMPATIBLE WITH THE CAULKING MATERIAL, TO WITHIN THE PROPER DISTANCE OF THE FINISHED JOINTi THEN FILL JOINT WITH CAULKING MATERIAL. PROTECT ADJACENT AREAS NOT TO RECEIVE SEALANTS AND CAULKING, REMOVE PROMPTLY IF CAULKING OR SEALANT DOES GET ON THESE SURFACESi CLEAN SATISFACTORILY OR REPLACE SURFACES WITH NEW MATERIALS. USE GUN NOZZLES TO FIT JOINTS, FINISH JOINTS NEATLY. REMOVE EXCESS MATERIAL, LEAVE JOINTS CLEAN. B. CAULK JOINTS BETWEEN DOOR AND WINDOW FRAMES AND ADJOINING WORK, AT ALL JOINTS BETWEEN DIFFERENT MATERIALS, AND ELSEWHERE AS SHOWN OR REQUIRED TO SEAL JOINTS WIND AND WATER TIGHT, EXERCISE CARE TO SEAL ALL OPENINGS IN EXTERIOR WALLS TO BE WIND, WATER AND INSECT TIGHT. C, USING SPECIFIED SEALANT, SEAL BETWEEN FOOD SERVICE EQUIPMENT AND ADJOINING WALL, BASES, ETC., AS REQUIRED TO SEAL CRACKS OR OTHER OPENINGS, AND AROUND PIPES, SO TO PREVENT ACCESS OF VERMIN AND ACCUMULATION OF CRUMBS, GREASE OR OTHER FOREIGN SUBSTANCES, DIVISIONS - DOORS AND WINDOWS SECTION 08100 STEEL DOORS AND FRAMES PART ONE - GENERAL 1.01 SCOPE THE WORK OF THIS SECTION INCLUDES FURNISHING OF ALL HOLLOW METAL DOORS AND STEEL FRAMES. INSTALLATION OF DOORS AND FRAMES IS INCLUDED UNDER SECTION 06200. 1,02 MARKING SHIP DOORS AND FRAMES TO JOB WITH EACH ITEM IDENTIFIED WITH ARCHITECT'S MARK 1.02 PROTECTION AND CLEANING PROTECT ALL DOOR FRAMES AND DOORS FROM DAMAGE DURING TRANSPORTATION AND AT THE JOB SITE] STORE AT THE SITE UNDER COVER ON WOOD BLOCKING OR ON SUITABLE FLOOR, AFTER INSTALLATION, PROTECT FROM DAMAGE DURING SUBSEQUENT CONSTRUCTION ACTIVITIES. DAMAGED WORK WILL BE REJECTED AND SHALL BE REPLACED WITH NEW WORK. PART TWO - MATERIALS 2,01 METAL FRAMES FLUSH DOUBLE RABBIT ARC-WEIDED FRAMES BY RDL SUPPLY, OF DEPTHS AND CONFIGURATIONS SHOWN ON THE DRAWINGS. PROVIDE WEATHER HOOD FULL WIDTH OF FRAME AT HEAD ON EXTERIOR SIDE OF EXTERIOR DOORS. PREPARE FRAME AT FACTORY FOR HARDWARE INSTALLATION, PROVIDE METAL ANCHORS OF SHAPES AND SIZES INDICATED ON JAMBS NEAR TOP AND BOTTOM OF EACH FRAME, AND AT INTERMEDIATE POINTS NOT OVER 24' ON CENTER. PR❑VIDE TEMPORARY STEEL SPREADERS FASTENED ACROSS BOTTOM OF FRAMES. WHERE CONSTRUCTION WILL PERMIT CONCEALMENT, LEAVE SPREADERS IN PLACE AFTER INSTALLATIONi OTHERWISE, REMOVE SPREADERS AFTER FRAMES ARE SET AND ANCHORED, 2.02 HOLLOW METAL DOORS METAL FRAMES BY RDL SUPPLY, WITH METAL FRAME VIEW PANEL AS SHOWN ON THE DRAWINGS. PREPARE FOR HARDWARE SPECIFIED IN SECTION 08700, PROVIDE TOP CAP FOR WEATHER PROTECTION, 2,03 SHOP PAINTING CLEAN AND CHEMICALLY TREAT (PHOSPHATES) METAL SURFACES TO ASSURE MAXIMUM PAINT ADHERENCE! FOLLOW WITH A DIP OR SPRAY COAT OR RUST -INHIBITIVE METALLIC OXIDE, ZINC CHROMATE, OR SYNTHETIC RESIN PRIMER ON ALL EXPOSED SURFACES, FINISH SURFACES SHALL BE SMOOTH AND FREE FROM IRREGULARITIES AND ROUGH SPOTS, EACH COAT OF PAINT SHALL BE SEPARATELY BAKED OR OVEN DRIED, SECTION 08250 FLUSH WOOD DOORS PART ONE - GENERAL 1,01 SCOPE OF WORK A. PR❑VIDE SOLID FLUSH DOORS, COMPLETE IN PLACE WITH FINISH HARDWARE INSTALLED, WHERE SHOWN ON THE DRAWINGS, AS SPECIFIED HEREIN, AND AS NEEDED FOR A COMPLETE AND PROPER INSTALLATION. 1,02 QUALITY ASSURANCE A, USE ADEQUATE NUMBERS OF SKILLED WORKMEN WHO ARE THOROUGHLY TRAINED AND EXPERIENCED IN THE NECESSARY CRAFTS AND WHO ARE COMPLETELY FAMILIAR WITH THE SPECIFIED REQUIREMENTS AND THE METHODS NEEDED FOR PROPER PERFORMANCE OF THE WORK OF THIS SECTION. B. IN ADDITION TO COMPLY WITH PERTINENT CODES AND REQUIREMENTS OF GOVERNMENTAL AGENCIES HAVING JURISDICTION, COMPLY WITHi 1. 'MANUAL OF MILLWORK' OF THE WOODWORK INSTITUTE OF CALIFORNIA, FOR THE GRADE OR GRADES SPECIFIED) OR 2. 'ARCHITECTURAL WOODWORK QUALITY STANDARDS' OF THE ARCHITECTURAL WOODWORK INSTITUTE FOR THE GRADE OR GRADES SPECIFIED, 3. CERTIFICATION AND STAMPS WILL NOT BE REQUIRED, 1,03 DELIVERY, STORAGE AND HANDLING A. DELIVERY, 1. DELIVER DOORS TO SITE AFTER BUILDING HAS REACHED AVERAGE PREVAILING HUMIDITY OF ITS LOCALITY, 2. DELIVER DOORS IN MANUFACTURER'S ORIGINAL CONTAINERS, CLEARLY MARKED WITH MANUFACTURER'S NAME, BRAND NAME, SIZE, THICKNESS, AND IDENTIFYING SYMBOL ON THE COVERING. 3. SEAL ALL FOUR EDGES OF THE UNFINISHED DOORS WHEN DELIVERED TO THE JOB SITE, B. STORAGEt 1. STACK DOOR FLAT ON 2 X 4 LUMBER, LAID 12' FROM ENDS AND ACROSS CENTER. 2. UNDER BOTTOM DOOR AND OVER TOP OF STACK, PROVIDE PLYWOOD OR CORRUGATED CARDBOARD TO PROTECT DOOR SURFACES, 3. STORE DOORS IN AREA WHERE THERE WILL BE NO GREAT VARIATIONS IN HEAT, DRYNESS, AND HUMIDITY, C. DO NOT DRAG DOORS ACROSS ONE ANOTHERi LIFT DOORS AND CARRY THEM INTO POSITION. PART TWO - PRODUCTS 2,01 GENERAL A. PROVIDE SOLID FLUSH WOOD DOORS OF THE TYPES, DESIGNS, AND THICKNESSES SHOWN ON THE DRAWINGS, LABELED OR NON - LABELED AS INDICATED AND REQUIRED, AND IN SOLID CORE OR HOLLOW CORE SHOWN ON THE DRAWINGS, B. GRADEi EXCEPT AS MAY BE SHOWN OTHERWISE ON THE DRAWINGS, FABRICATE THE WORK OF THIS SECTION TO 'CUSTOM GRADE' STANDARDS OF THE REFERENCED ORGANIZATIONS, C. FOR HOLLOW CORE DOORS, PROVIDE CARE CONSTRUCTION AS NEEDED TO ACCOMMODATE FINISH HARDWARE. D. SPECIESt 1. WHERE PAINT GRADE OR OPAQUE FINISH ARE CALLED FOR ON THE DRAWINGS, PROVIDE BIRCH OR BEECH FACES FOR OPAQUE FINISH. 2. FOR ALL OTHER FLUSH WOOD DOORS, PROVIDE RIFT CUT WHITE OAK FACES FOR TRANSPARENT FINISH, PART THREE - EXECUTION 3.01 SURFACE CONDITIONS A. EXAMINE THE AREAS AND CONDITIONS UNDER WHICH THE WORK OF THIS SECTION WILL BE PERFORMED, CORRECT CONDITIONS DETRIMENTAL TO TIMELY AND PROPER COMPLETION OF THE WORK, DO NOT PROCEED UNTIL SATISFACTORY CONDITIONS ARE CORRECTED. 3,02 INSTALLATION A. FITTING AND MATCHING, 1. UNLESS DOORS ARE COMPLETELY FITTED AND MACHINED AT THE MILL, FIT THEM FOR WIDTH BY PLANNING AND FIT THEM FOR HEIGHT BY SAWING, a. BOTTOM, 1/2' CLEARANCE MAXIMUM b, TOPt 1/8' CLEARANCE MINIMUM C. LOCK EDGE AND HINGE EDGE, BEVEL 1/8' IN 2' MAXIMUM 2. MACHINE DOORS FOR HARDWARE IN ACCORDANCE WITH RECOMMENDATIONS OF THE HARDWARE MANUFACTURERS, AS THOSE RECOMMENDATIONS HAVE BEEN APPROVED BY THE ARCHITECT, B, RECEIVE AND RETAIN CUSTODY OF FINISH HARDWARE FURNISHED FOR THE WORK OF THIS SECTION EXCEPT AS OTHERWISE DIRECTED BY THE ARCHITECT. INSTALL ALL SUCH FINISH HARDWARE IN STRICT ACCORDANCE WITH THE RECOMMENDATIONS OF ITS MANUFACTURER. C. REPLACE OR REHANG DOORS WHICH ARE HINGE BOUND AND DO NOT SWING OR OPERATE FREELY. SECTION 08400 ALUMINUM FRAMING (IF REQUIRED PER DRAWINGS) PART ONE - GENERAL 1,01 SCOPE THE WORK OF THIS SECTION INCLUDES ALUMINUM STOREFRONT MATERIAL AND WINDOW ASSEMBLIES. PART TWO - MATERIALS 2.01 WINDOW FRAMING DESIGN IS BASED ON USE OF KAWNEER TRIFAB NO, 451 SERIES FRAMING, AS INDICATED ON THE DRAWINGS, FINISH SHALL BE KAWNEER NO, 17 CLEAR ANODIZED, 2.02 ALUMINUM SPECIALTIES A. COLUMN COVERS AND AT SILLS OF WINDOWS, .040' ANODIZED ALUMINUM, FINISH TO MATCH FRAMING, B. DRIP STRIP AT WINDOW HEADS, .032' ANODIZED ALUMINUM, FINISH TO MATCH FRAMING, 2.03 CAULKING AS SPECIFIED IN SECTION 07900, AND AS RECOMMENDED BY ALUMINUM FRAMING MANUFACTURER. 2.04 FASTENERS USE ONLY HARD ALUMINUM ALLOY OR NON-MAGNETIC STAINLESS STEEL SCREWS AND BOLTS, PART THREE - EXECUTION 3.01 GENERAL CAREFULLY ERECT ALL WORK PLUM, TRUE, SQUARE IN OPENINGS AND SECURELY ANCHOR IN PLACE. PROTECT ALUMINUM SURFACES FROM CONTACT WITH STEEL OR MASONRY WITH TWO COATS OF ZINC CHROMATE PAINT. 3,02 FRAMING INSTALLATION INSTALL WINDOW FRAMING AS INDICATED ON THE DRAWINGS, SET ON P❑LYSULFIDE CAULKING BEAD, AND SECURELY ATTACH TO WOOD SUB - FRAME, SECTION 08700 FINISH HARDWARE PART ONE - GENERAL 1,01 WORK INCLUDED INSTALLATION OF FINISH HARDWARE IS COVERED UNDER SECTION 06200, FURNISH ALL FINISH HARDWARE AND RELATED ITEMS NECESSARY TO COMPLETE THE WORK, 1,02 PRODUCT HANDLING INDIVIDUALLY PACKAGE EACH UNIT OF FINISH HARDWARE COMPLETE WITH PROPER FASTENINGS AND APPURTENANCES, CLEARLY IDENTIFIED, 1.03 GUARANTEE ANY HARDWARE, WHICH PROVES TO BE DEFECTIVE OR FAULTY WITHIN A PERIOD OF ONE YEAR, SHALL BE REPLACED AT NO COST TO THE OWNER, PART TWO - PRODUCTS 2,01 GENERAL A. FURNISH HARDWARE IN ACCORDANCE WITH HARDWARE SCHEDULE. FURNISH EACH KIND OF HARDWARE FROM ONLY ONE MANUFACTURER, B. FINISHES OF ALL HARDWARE SHALL MATCH THE FINISH OF THE LOCKSETS, UNLESS OTHERWISE SCHEDULED, A. FURNISH NON -REMOVABLE PINS AT OUT SWINGING EXTERIOR DOORS. D. CLOSERS, SIZE THE CLOSERS IN ACCORDANCE WITH THE MANUFACTURER'S WRITTEN RECOMMENDATIONS. FURNISH SEX BOLTS FOR CLOSERS TO BE MOUNTED IN PARTICLEBOARD OF MINERAL CORE DOORS, E, DOOR SILENCERS, FURNISH THREE SILENCERS FOR EACH STEEL DOOR FRAME. F. HAND OF DOORi THE DRAWINGS SHOW THE SWING OF EACH DOOR LEAF, FURNISH EACH ITEM OF HARDWARE FOR PROPER INSTALLATION AND OPERATION OF THE DOOR SWING AS SHOWN, G. FASTENERSt FURNISH ALL NECESSARY SCREWS, BOLTS, AND OTHER FASTENERS OF SUITABLE SIZE AND TYPE ACCORDING TO THE MATERIAL TO WHICH THE HARDWARE IS TO BE APPLIED AND THE RECOMMENDATIONS OF THE HARDWARE MANUFACTURER, ALL FASTENINGS SHALL HARMONIZE WITH THE HARDWARE AS TO MATERIAL AND FINISH, 2.02 KEYING A. KEY LOCKS IN DOORS INDIVIDUALLY, FURNISH 2 KEYS PER LOCK, 2.03 HARDWARE SCHEDULE SEE DOOR SCHEDULE ON THE DRAWINGS, DIVISION 9 - FINISHES SECTION 09250 GYPSUM DRYWALL PART ONE - GENERAL 1.01 SCOPE THIS SECTION INCLUDES MATERIALS, INSTALLATION AND FINISHING OF JOINTS FOR GYPSUM DRYWALL WALLS AND CEILINGS, 1.02 MATERIAL HANDLING DELIVER ALL MATERIALS IN ORIGINAL UNOPENED PACKAGES AND STORE IN AN ENCLOSED SHELTER PROVIDING PROTECTION FROM DAMAGE AND EXPOSURE TO THE ELEMENTS, REMOVE DAMAGED OR DETERIORATED MATERIALS FROM THE PREMISES. 1.03 JOB CONDITIONS IN COLD WEATHER AND DURING GYPSUM PANEL APPLICATION AND JOINT FINISHING MAINTAIN TEMPERATURES WITHIN THE BUILDING WITHIN THE RANGE OF 50 F TO 70 F. PROVIDE ADEQUATE VENTILATION TO REMOVE EXCESS MOISTURE. 1.04 RELATED WORK WOOD FRAMING IS INCLUDED IN SECTION 06100. STEEL STUD FRAMING IS INCLUDED IN SECTION 05400, PART TWO - MATERIALS 2.01 GYPSUM BOARD TAPERED EDGE, THICKNESS AS INDICATED ON DRAWINGS, BY GOLD BOND OR EQUAL, USE REGULAR 5/8' FIRE SHIELD AND M❑ISTURE RESISTANT (MR) 5/8' BOARD SUBSTRATE FOR ALL CERAMIC WALL TILE FINISHES. 2.02 FASTENERS FOR ATTACHMENT OF GYPSUM BOARD PANELS TO WOOD FRAMING AND STEEL STUD FRAM F FRAMING, USE BUGLE HEAD DRYWALL SCREWS EQUAL T❑ GOLD BOND, SPACING ❑ S CI G PER MANUFACTURER'S RECOMMENDATIONS, 2,03 TRIM GOLD BOND CASING BEAD NO. 100 OR EQUAL, 2,04 CORNER BEAD GOLD BOND MULTI -FLEX TAPE BEAD OR EQUAL, 2.05 JOINT TREATMENT GOLD BOND REINFORCING TAPE AND J❑INT COMPOUND. PART THREE - EXECUTION 3,01 GYPSUM PANEL ERECTION APPLY GYPSUM PANELS WITH LONG DIMENSION PERPENDICULAR TO FRAMING. POSITION ALL END JOINTS OVER FRAMING MEMBERS, USE MAXIMUM PRACTICAL LENGTHS TO MINIMIZE END JOINTS, FIT END AND EDGES CLOSELY, BUT NOT FORCED TOGETHER, STAGGER JOINTS ON OPPOSITE SIDES OF PARTITION, 3.02 A. FINISH ALL FACE PANEL JOINTS AND INTERNAL ANGLES WITH JOINT TREATMENT INSTALLED ACCORDING TO MANUFACTURER'S DIRECTIONS, SPOT EXPOSED FASTENERS ON FACE LAYERS AND FINISH CORNER BEAD, CONTROL JOINTS AND TRIM AS REQUIRED, WITH AT LEAST THREE COATS OF J❑INT COMPOUND FEATHERED OUT ONTO PANEL FACES AND SANDED SMOOTH, B, REINFORCE ALL VERTICAL AND HORIZONTAL EXTERIOR CORNERS WITH CORNER BEAD FASTENED WITH 9/16' ROSIN COATED STAPLES 12' D.C. ON BOTH FLANGES ALONG ENTIRE LENGTH OF BEAD, C, WHERE ASSEMBLY TERMINATES AGAINST DISSIMILAR MATERIAL OR AT DISCONTINUOUS EDGES (EXCEPT BEHIND CERAMIC TILE), APPLY TRIM OVER PANEL EDGE AND FASTEN WITH SCREWS 12' O.C, D, POWER -DRIVE FASTENERS AT LEAST 3/8' FROM EDGE OR ENDS OF PANELS TO PROVIDE UNIFORM DIMPLE 1/32' DEEP, SECTION 09300 TILE PART ONE - GENERAL 1.01 SCOPE A. THIS SECTION INCLUDES MATERIALS AND INSTALLATION OF FLOOR AND WALL TILES, 1. CERAMIC TILE, AS SPECIFIED ON THE DRAWINGS, 2, QUARRY TILE, AS SPECIFIED ON THE DRAWINGS, 1.02 QUALITY ASSURANCE A, PROVIDE PRODUCTS OF THE FOLLOWING, B. TILE COUNCIL OF AMERICA STANDARD 137.1 IS THE BASIS FOR REQUIREMENTS. 1.03 PRODUCT HANDLING A, DELIVER PACKAGED MATERIALS AND STORE IN ORIGINAL CONTAINERS WITH SEALS UNBROKEN AND LABELS INTACT UNTIL TIME OF USE, 1.04 JOB CONDITIONS MAINTAIN ENVIRONMENTAL CONDITIONS AND PROTECT WORK DURING AND AFTER INSTALLATION IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS, PART TWO - PRODUCTS 2,01 TILE PRODUCTS AS SPECIFIED ON THE DRAWINGS, 2.02 GROUT AS SPECIFIED ON THE DRAWINGS. PART THREE - EXECUTION 3,01 TILE INSTALLATION STANDARDS A. COMPLY WITH APPLICABLE REQUIREMENTS OF THE FOLLOWING AMERICAN NATIONAL STANDARDS INSTITUTE STANDARDS. 1. A108,4 FOR TILE INSTALLED WITH ORGANIC ADHESIVE. 2. A108,5 FOR TILE INSTALLED WITH DRY -SET PORTLAND CEMENT MORTAR OR LATEX-PORTLAND CEMENT MORTAR, 3. A108.6 FOR TILE INSTALLED WITH EPDXY ADHESIVE, B, COMPLY WITH MANUFACTURER'S INSTRUCTIONS FOR MIXING AND INSTALLATION OF PROPRIETARY MATERIALS. 3,02 INSTALLATION A. EXTEND TILE WORK INTO RECESSES AND UNDER OR BEHIND EQUIPMENT AND FIXTURES, TO FORM A COMPLETE COVERING WITHOUT INTERRUPTIONS. B. ACCURATELY FORM INTERSECTIONS AND RETURNS, PERFORM CUTTING AND DRILLING OF TILE WITHOUT MARRING VISIBLE SURFACES, CAREFULLY GRIND CUT EDGES OF TILE ABUTTING TRIM, FINISH OR BUILT-IN ITEMS FOR STRAIGHT ALIGNED SURFACES, C. INSTALL TILE USING THE FOLL❑WING SETTING BEDS AS SHOWN OR SCHEDULED, 1. QUARRY TILE FLOORS, DRY -SET PORTLAND CEMENT MORTAR OR LATEX- PORTLAND CEMENT MORTAR OVER CONCRETE 2, GLAZED WALL TILE, ORGANIC ADHESIVE, 3. QUARRY TILE FLOORS IN COOLER/FREEZER, SET WITH EPDXY ADHESIVE. D, UNLESS OTHERWISE SHOWN, LAY TILE IN GRID PATTERN, ALIGN JOINTS WHEN ADJOINING TILES ON FLOOR, BASE, WALLS AND TRIM AREA SAME SIZE. LAYOUT TILE WORK AND CENTER TILE FIELDS IN BOTH DIRECTIONS IN EACH SPACE, ADJUST TO MINIMIZE TILE CUTTING. PROVIDE UNIFORM JOINT WIDTHS, UNLESS OTHERWISE SHOWN, E. INSTALL EXPANSION JOINTS MAXIMUM 16' - 0' D.C.., IN EACH DIRECTION, 3,03 CLEANING AND PROTECTION A. UPON COMPLETION OF PLACEMENT AND GROUTING, CLEAN ALL TILE SURFACES S❑ THEY ARE FREE OF FOREIGN MATTER. B. LEAVE FINISHED INSTALLATION CLEAN AND FREE OF CRACKED, CHIPPED, BROKEN, UN -BONDED, OR OTHERWISE DEFECTIVE TILE WORK. C. PROHIBIT FOOT AND WHEEL TRAFFIC FROM USING TILES FLOORS FOR AT LEAST THREE (3) DAYS AFTER GROUTING IS COMPLETED, D. COVER ALL TILE FLOORS WITH 'KRAFT PAPER' IN ALL AREAS AND D❑ NOT REMOVE THE PAPER UNTIL FINAL CLEAN UP AT COMPLETION OF CONSTRUCTION. �y c o :200 c oQ E U- o 47 N � c � � o 11 o a- o N /� 04 r C v O� a o M M J LL 0 Ua o O* O z rn C o CUa�i Q' U a t O C' C 2LO J C Q J O J N_ LL 06 U .y °c ti 0 N �ry It Cr) W W� J o N UC=LL O n.. -J m J �QQ! W 66 W N (0 N Revisions: U) Z 060 W Q FU p LL ZU W CL W Project Number 07059 Date 02-28-08 Sheet Number Gl .3 II I I 1 1 II 11 it SECTION 09500 LAY - IN CEILINGS PART ONE - GENERAL 1.01 SCOPE FURNISH LABOR, EQUIPMENT, AND MATERIALS TO COMPLETE THE INSTALLATION OF ALL LAY -IN CEILING MATERIALS AND SUSPENSION SYSTEMS, 1.01 SUBMITTALS COMPLY WITH SECTION 10750, SUBMIT SAMPLES FOR APPROVAL, 1.02 JOB CONDITIONS NO WORK IS TO BE STARTED UNTIL ALL EXTERIOR OPENINGS ARE CLOSED IN, ALL WET WORK SHALL BE COMPLETED AND DRIED BEFORE WORK IS STARTED, PART TWO - MATERIALS 2.01 CEILING PANELS COLOR, TYPE, PATTERN, SIZE, ETC., AS SCHEDULED AND SHOWN ON THE DRAWINGS, EXPOSED GRID SUSPENSION SYSTEM, CHICAGO METALLIC NO. 200 SERIES SNAP GRID SYSTEM WITH WALL ANGELS, NO, 1409, L❑-GLOSS WHITE BAKED ENAMEL PAINT FINISH. PART THREE - EXECUTION 3.01 INSTALLATION IN STRICT ACCORDANCE WITH MANUFACTURER'S PRINTED INSTRUCTION, SUSPEND MAIN TEES FROM STRUCTURE USING NO, 9 GAUGE WIRE HANGERS AT 48' CENTER. LOCK CROSS TEES IN PLACE AT EVERY INTERSECTION WITH MAIN RUNNERS, AND WALL ANGLES WITH ENDS OF TEES RESTING ON BOTTOM FLANGE, SECURE WALL ANGLES TO SUBSTRATE WITH SUITABLE FASTENERS AND ANCHORS, SUPPORT ALL LAY- IN UNITS ON ALL FOR SIDES, PROVIDE EXTRA HANGERS IF REQUIRED. SUSPEND SURFACE MOUNTED FIXTURES FROM BUILDING STRUCTURE AND PULL TIGHTLY AGAINST CEILING. COORDINATE WITH THE ELECTRICAL CONTRACTOR REGARDING SUSPENSION OF ELECTRICAL CEILING FIXTURES FROM THE CEILING SUSPENSION. 3.02 CLEAN-UP AT COMPLETION OF THE WORK, REMOVE ALL SCAFFOLDING, CONTAINERS AND OTHER RUBBISH FROM THIS PORTION OF THE WORK FROM THE SITE. LEAVE ALL TILE SUPPORTING MEMBERS FIRMLY AND SECURELY ANCHORED, FREE OF FINGER MARKS OR SMUDGES AND IN PERFECT CONDITION. DIVISION 10 SPECIALTIES SECTION 10260 CORNER GUARDS CIF REQUIRED PER DRAWINGS) PART ONE - GENERAL 1.01 GENERAL FURNISH LABOR, EQUIPMENT, AND MATERIALS TO COMPLETE THE INSTALLATION OF ALL RUBBER OR VINYL CORNER GUARDS, 1.01 SUBMITTALS COMPLY WITH SECTION 10750, SUBMIT SAMPLES FOR APPROVAL. PART TWO - MATERIALS 2.01 CORNER GUARDS A. APPROXIMATE SIZE SHALL BE 2' X 2' FULL HEIGHT. COLOR SHALL BE WHITE OR CLEAR TO MATCH ADJACENT WALL FINISHES. VERIFY COLOR WITH CONSTRUCTION MANAGER. B. PROVIDE RUBBER OR VINYL CORNER GUARDS BY ONE OF THE FOLLOWING MANUFACTURERS OR OWNER APPROVED SUBSTITUTIONS. 1. JOHNSONITE - MIDDLEFIELD, OHI❑ (216-543-8916) 2. ROPPE - FOSTORIA, ❑HIO (419-435-8546) 3. RC MUSSON RUBBER CO., - AKRON, OHI❑ (216-773-7651) 4. MERCER PRODUCTS COMPANY, INC., - ❑RLANDO, FLORIDA (407-578-2900) C. PROVIDE STAINLESS STEEL CORNER GUARDS CIF REQUIRED PER DRAWINGS) BY ONE MANUFACTURER'S ALIKE AND AS FOLLOWS, PROVIDE APPROXIMATELY 2' X 2' BY FULL WALL HEIGHT STAINLESS STEEL CORNER GUARDS AT L❑CATION S AS SHOWN ON THE DRAWINGS BY ONE OF THE FOLLOWING MANUFACTURERS OR OWNER APPROVED SUBSTITUTIONS, 1, K.J. MILLER CORPORATION, ELKHARD, IN (800-34-7584) 2. PAWLING CORPORATION, PAWLING, NY (914-855-1005) 3. AMERICAN FLOOR PRODUCTS CO., INC. ROCKVILLE, MD (800-342-0424) 4. MCKINNEY/PARKER DIVISION, SCRANTON, PA (717-348-7551) OR (415-282-7800) PART THREE - EXECUTION 3.01 GENERAL INSTALL CORNER GUARDS WHERE NOTED ON THE DRAWINGS AND PER MANUFACTURER'S WRITTEN INSTRUCTIONS. SECTION 10290 PEST CONTROL PART ONE - GENERAL 1.01 SCOPE FURNISH LABOR, EQUIPMENT AND MATERIALS TO COMPLETE THE APPLICATION OF INSECTICIDE. 1.02 SUBMITTALS COMPLY WITH SECTION 10750, SUBMIT SAMPLES FOR APPROVAL. PART TWO - MATERIALS 2.01 PEST CONTROL PRODUCT PERMA-DUST PT240 BORIC - ACID- BASED INSECTICIDE BY WHITMIRE RESEARCH LABORATORIES INC., ST. LOUIS, MO (314-225-5713), OR OWNER APPROVED SUBSTITUTION, PART THREE - EXECUTION 3.01 GENERAL APPLY AT THE RATE OF 150 SQUARE FEET PER 20 ❑Z., AEROSOL CAN TO FLAT SIDES OF STUDS OF PERIMETER WALLS, INSIDE OF PERIMETER WALL SHEATHING TOP SIDE OF GYPSUM BOARD CEILING MATERIAL AND ALL OTHER AREAS CIF ANY) INDICATED ON THE DRAWINGS. APPLY JUST PRIOR TO COVERING OR ENCLOSING. APPLY IN STRICT CONFORMANCE WITH MANUFACTURERS RECOMMENDATIONS. SECTION 10310 TILE BACKER BOARD PART ONE - GENERAL 1.01 SCOPE FURNISH LABOR, EQUIPMENT, AND MATERIALS TO COMPLETE THE INSTALLATION OF CEMENTI❑US TILE BACKER BOARD 1.02 SUBMITTALS COMPLY WITH SECTION 10750, SUBMIT SAMPLES FOR APPROVAL, PART TWO - MATERIALS 2.01 CEMENTIOUS TILE BACKER BOARD DUROCK CEMENT BOARD - 5/8' THICK - UNITED STATES GYPSUM COMPANY, P.O. BOX 806278, CHICAGO, IL 60680-4124. PART THREE - EXECUTION 3.01 GENERAL APPLY IN LOCATIONS AS DIRECTED IN SECTIONS AND DETAILS. USE POSITIVE ATTACHMENT OF BUGLE HEAD DRYWALL SCREWS, EXTERIOR SIGNAGE (IF REQUIRED PER DRAWINGS) SECTION 10430 EXTERIOR SIGNAGE PART ONE - GENERAL 1.01 SCOPE FURNISH LABOR, EQUIPMENT, AND MATERIALS TO COMPLETE THE INSTALLATION OF ALL EXTERIOR SIGNAGE. PART TWO - MATERIALS 2.01 EXTERIOR SIGNAGE A. OWNER SHALL SUPPLY ALL EXTERIOR SIGNAGE. CONTRACTOR SHALL INSTALL EXTERIOR SIGNAGE PER MANUFACTURER'S INSTALLATION INSTRUCTIONS. B. CONTRACTOR SHALL COORDINATE ELECTRICAL INSTALLATION AND FINAL ELECTRICAL CONNECTIONS FOR EXTERIOR SIGNAGE UNLESS OTHERWISE INDICATED. SECTION 10440 INTERIOR SIGNAGE CIF REQUIRED PER DRAWINGS) PART ONE - GENERAL 1.01 SCOPE FURNISH LABOR, EQUIPMENT, AND MATERIALS TO COMPLETE THE INSTALLATION OF ALL INTERIOR SIGNAGE, PART TWO - MATERIALS 2.01 INTERIOR SIGNAGE A. OWNER SHALL SUPPLY ALL INTERIOR SIGNAGE, CONTRACTOR SHALL INSTALL INTERIOR SIGNAGE PER MANUFACTURER'S INSTALLATION INSTRUCTIONS. B. CONTRACTOR SHALL SUPPLY AND INSTALL ALL REQUIRED BLOCKING IN WALLS AS REQUIRED. C. CONTRACTOR SHALL COORDINATE ELECTRICAL INSTALLATION AND FINAL ELECTRICAL CONNECTIONS FOR INTERIOR SIGNAGE UNLESS ❑THERWISE INDICATED. SECTION 10520 FIRE EXTINGUISHERS PART ONE - GENERAL 1.01 SCOPE FURNISH LABOR, EQUIPMENT, AND MATERIALS TO COMPLETE THE INSTALLATION OF ALL FIRE EXTINGUISHERS. PART TWO - MATERIALS 2.01 FIRE EXTINGUISHERS A. FIRE EXTINGUISHERS SHALL BE MULTIPURPOSE DRY CHEMICAL TYPE RATE 4-A, 60-BC, 10LB. NOMINAL CAPACITY] IN ENAMELED STEEL CONTAINER, FOR CLASS A, CLASS B AND CLASS C FIRES. PROVIDE MANUFACTURER'S STANDARD BRACKET FOR EXTINGUISHER UL AND FM LISTED UNIT AS MANUFACTURED BY ONE OF THE FOLLOWING, 1. J.L. INDUSTRIES 2. LARSEN'S MANUFACTURING COMPANY 3. MUCKLE MANUFACTURING DIVISION OF TECHNICO, INC. 4, PROFILE INTERNATIONAL, INC, 5, BADGER PART THREE - EXECUTION 3.01 GENERAL CONTRACTOR SHALL INSTALL FIRE EXTINGUISHERS AS INDICATED ON THE DRAWINGS OR IF NOT INDICATED ON THE DRAWINGS, AS DIRECTING BY THE LOCAL FIRE MARSHAL TO COMPLY WITH APPLICABLE GOVERNING REGULATIONS. SECTION 10800 TOILET ACCESSORIES PART ONE - GENERAL 1.01 SCOPE THE WORK IN THIS SECTION INCLUDES ACCESSORIES IN TOILETS. PART TWO - MATERIALS 2.01 ACCESSORIES PR❑VIDE TOILET ACCESSORIES TO MEET AMERICANS WITH DISABILITIES ACT ACCESSIBILITY GUIDELINES (ADAAG) AS SHOWN ON THE DRAWINGS AND OR OWNER APPROVED SUBSTITUTIONS. PART THREE - EXECUTION 3.01 INSTALLATION ERECT ITEMS IN A RIGID SUBSTANTIAL MANNER, IN CORRECT POSITIONS, AND LEVEL & PLUM. FULLY TRIM IN WHERE REQUIRED. INSTALL TOILET ACCESSORIES PER ADAAG GUIDELINES. DIVISION 11 - EQUIPMENT SECTION 11400 FOOD SERVICE EQUIPMENT PART ONE - GENERAL 1.01 SCOPE A. WHERE FIXED FOOD SERVICE EQUIPMENT ABUTS OTHER EQUIPMENT OR CONSTRUCTION, SEAL RESULTING JOINT TO MAKE IT SANITARY FOR CLEANING PURPOSES, PROVIDE BACKER ROD WHEN REQUIRED. USE ONLY RTV ADHESIVE/SEALANT APPROVED BY NSF 1. SILASTIC 732 DOW CORNING CORPORATION, MIDLAND, MI (517-496-6000) FOR USE IN FOOD ZONES, PRODUCTS MEETING THIS REQUIREMENT INCLUDE THE 2. SILITE DEVC❑N CORPORATION, DANVERS, MA (617-777-1100) FOLL❑WING, 3. RTV100-SERIES, GENERAL ELECTRIC COMPANY, WATERFORD, NY (518-266-2315) B. CLEAN AND PRIME OR SPOT PRIME SURFACES TO RECEIVE SEALANT AS REQUIRED. COLOR TO BE CLEAR OR TO MATCH ADJACENT SURFACES, C. ITEMS REQUIRING SEALANT INCLUDE, BUT ARE NOT LIMITED TO, THE FOLLOWING, 1. MOP SINK 2. THREE COMPARTMENT SINK 3. PREP SINK 4. HAND SINKS 5. INSIDE AND OUTSIDE WALK-IN COOLER 6. EXHAUST HOOD DIVISION 12 - FURNISHINGS (NOT USED) DIVISION 13 - SPECIAL CONSTRUCTION (NOT USED) DIVISION 14 - CONVEYING SYSTEMS (NOT USED) DIVISION 15 - MECHANICAL (SEE MECHANICAL DRAWINGS) DIVISION 16 - ELECTRICAL (SEE ELECTRICAL DRAWINGS) U8 N N 0 y o 00 J c �' JU. o � � o N t0 ♦ ^ N � CC C � o ¢ O r o_ 0 JM J LL rn 0 a� Ua > o O r Lo o z o c � a c N J C J O Q y o J ti L U C CC t` 0 0 N J�04 J > cci W W o .J N Q D LL, O a. m J �_-CLJ J = w U ="_ a U WOOw NCDN Revisions: W Z 060 Q � U LL O _ ZU W CL W Project Number 07059 Date 02-28-08 Sheet Number G1.4 1 I I 'I 1 9 ! I I_ I I 1 1 1IN41111 _ L 1 CONCRETE PLAN 4!:�-� S —1 SCALES 1/4' = 1'-0' D FUTURE SLAB ONE -HOUR TENANT SEPERATI❑N WALL (SEE DETAIL 3/A7.1) PR❑VIDE KEYED NOTCH IN EDGE OF CONC. TO RECEIVE FUTURE SLAB 77, d: ° Q 4' TFIIG�C,G❑NC SLAB • °. • d /' F�£fd+JF�RG`R�D'1�/ 'WWF ° 6X6-W �, 4 N 6 tYE 1 0 REIDIf F TTQhi , 2 INTERIOR SLAB EDGE SCAM 7 N INTERI❑R FINISH (SEE DETAIL i/A7.11 4' THICK C❑NC, SLAB REINF❑RCED W/ WWF 6X6-W1.4XW1.4 ON 6 MIL. VAPOR BARRIER AND TERMITE TREATED COMPACTED S❑IL EXISTING EXTERI❑R C.M.U. WALL C❑NSTRUCTI❑N EXISTING CONT. CONCRETE F❑❑TING 3 INTERIOR SLAB EDGE S-1 SCALES 1-1/2'ni'-0' E U- C N J �x O co U C Jl 0 _ a .. r_ N f` N � U O Q O L 0 Q JCn M J LL 0 w M O pGo zco O C Q > $ O J CU Vl J OZI � Q U C o ti J LJL U a '• O c 0 0 0 N 0 NNEMMMONd J CM W w J ZN < =) U_ O � M Zi (Y .J w F- (,� �. Q W W 000 N CD N Revisions: WA Project Number 07059 EDate 02-28-08 Sheet Number S-1 -I i i 1 - 111 _ 119 1 11 1 - 1 ! LL— REFERENCE CODES 44.25 8.85 " EXISTING BUILDINGi FLORIDA EXISTING BUILDING CODE M 2004 EDITION -- >, 34" ALSO IN COMPLIANCE WITH 2O06 REVISIDNS BUILDINGi FLORIDA BUILDING CODE 2004 EDITION �1 o Q PLUMBINGi FLORIDA PLUMBING CODE 2004 EDITION 4 MECHANICAL, FLORIDA MECHANICAL CODE 2004 EDITION ELECTRICALi NATIONAL ELECTRICAL CODE r 1 .0 E 2002 EDITION CN c ■ ACCESSIBILITYi FLORIDA ACCESSIBILITY CODE J 04 °� > I FOR BUILDING CONSTRUCTION M c > LL O FBC 2004 EDITION CDLIFE> EE ■ LIFE SAFETY NFPA 101 LIFE SAFETY C❑DE ■� N.0 � MEN COOLER 2000 EDITION iio DESIGN CRITERIA L I a O 00010 FO OCCUPANCYi ASSEMBLY GROUP A2 (SECTION 303) QE10 ■ o CONSTRUCTION TYPES F.B.C. TYPE IIIB, FULLY SPRINKLERED (SECTION 602) J M PIZZA i • CORR, / O ® PREP I N.F,P.A. TYPE III C0,0,0) co 103 ■ WORK CLASSIFICATIONS ALTERATION LEVEL 3 (SECTION 303)06 0 I:DCD BUILDING PROGRAM U .: El ■ . cn PREP, , KITCHEN I RESTAURANT O s In 105 I ' THE PROJECT CONSISTS OF AN INTERIOR BUILD OUT OF A COMPLETED SHELL o 00 I STRUCTURE INTO A RESTAURANT CCICI'S PIZZA) WHICH WILL INCLUDE THE c Z� n FOLLOWING SPACES/R❑OMSi ENTRY Ul > d ® I ■ a I co SERVING > o U t WOMEN X'� DINING Ll KITCHEN O E y c 1 99 ■ GAME R❑OM M J J REST ROOMS r u II I I ALTERATION AREA CALCULATIONS > L3 p ■ EXISTING BUILDING AREA = 6,795 S,F. GROSSMR BEV, PROPOSED ALTERATION AREA = 3,986 S.F, GROSS > STATION PATH OF TRAVEL TO DISPLAY I o EXIT 102'-11 1/2" KITCHEN ■ (NOT TO EXCEED 200') 102 LIFE SAFETY LEGEND GAME ROOM PRIMARY EXIT 108 SECONDARY EXIT ■ Ia PULL STATION ■ SERVING I O SMOKE DETECTOR 103 O HEAT DETECTOR IO� HORN WITH STROBE U J � N �, O ■ U-) STROBE ONLY Q M o QWJ_j ® ILLUMINATED EXIT SIGN, SINGLE FACE, 0 N U u ■ DIRECTION ARROW - DINING O Z N Q COMBO EXIT/EMERGENCY LIGHT O '� m 107 O J A0 _j FRCP FIRE ALARM CONTROL PANEL {,L J = O LU U Q O O ORDER FAA FIRE ALARM ANNUNCIATOR Q U = � _ —1 _01 I �' M � EMERGENCY LIGHT N CO N ■ I® FIRE EXTINGUISHER IN CABINET ■ FIRE HOSE STATION Ll I a I 44.25 = OCCUPANT LOAD ■ 8.8 5" = REQUIRED EGRESS WIDTH (2 PER PERSON) 34" = PROVIDED WIDTH I ■ I I ■ I Revisions: o 0 0 0 0 j ENTRY ■ 100 i I ♦ / WALL LEGEND NON —RATED PARTITION ONE HOUR FIRE WALL 1 LIFE SAFETY PLAN O/ A 1,1 SCALES 1/4' = 1'-0' a D 44,25 44,25 44,25 LO 8,85" 8,85" 8,85" 34N 34" 34" LU Z rQ a V/ _j N Q LU z L o J LIFE SAFETY CALCULATIONS ASSEMBLY AREA SQ, FT./ OCCUPANT EXIT OCCUPANCY (SO. FT,) OCCUPANT LOAD COMPONENTS RESTURAUNT 2,572 15 171 LEVEL COM, KITCHEN 1,202 200 6 LEVEL TOTAL, 3,777 1 1 177 1 EXIT WIDTH/ PERSON (IN.) 0.20 0.20 REQ'D, OCCUP. LOAD EXIT WIDTH (IN,) 34.2 11,2 35.4 PROVIDED CLEAR EXIT WIDTH (IN,) 68 1 68 1 136 PROVIDED EXIT CAPACITY 340 1 340 1 680 Project Number 07059 Date 02-28-0$ Sheet Number A1.1 PLAN KEY NOTES i. i 0 i (U In lBUFFET SERVING COUNTER - SEE SHEET A3.2 15 T.G.C. SHALL PROVIDE A 2' HIGH CONCRETE PAD FOR THE STORE SAFE INSTALLATION. BAR - SEE SHEET A3.2 QUAYSALAD QT 2OFHALL THESIDESL& TOP THE PAD. TUG.C. HALL ❑ BEVERAGE STATION -SEE SHEET A10 BOLT THE SAFE DOWN AND/OR OTHERWISE INSTALL PER THE MANUFACTURER'S 76'-8' PAD. COORDINATE 7'-1 NATE' 11* x ENT OFCONC. RECOMMENDATIONS. VERIFY EXACT LIGHT ABOVE WITH TENANT. LOCATION WITH TENANT AND SEE SHEET A5. BOOTH WALL -SEE DETAIL 4 A7.2 / 16 WALL CLOSURE - SEE DETAIL 7/A7.3 4 SIGNAGE MOUNTED AT 60' A.F.F.TOREFRONT . 17 NOTES: ❑DOOR 6 - EXISTING ALUM. AND GLASS STOREFRONT ❑ENTRY 6 WALL - SEE SHEET 5/A7.2 TO REMAIN U.N.O. PARTIALLY -COVERED TRAY WELL - 18 ALL INT. FIN. TO MEET MIN. CLASS 'C' RATING. 111 12 a SEE DETAIL 1 /A3.2 ORDER AREA COUNTER - SEE 2/A7.2 19 BOTTOM 12 " OF WALLS IN ANY WET AREA SHALL RECEIVE 5/8"DUR-ROCK SEE DETAIL q A B A 6/A7.3 SIM. SEE SHEET A5.1 FOR TOILET ACCESSORIES AND LOCATIONS. 20 PLYWD IN RESTROOM HALL BE A 4'x8'x5/8" FRT SHEET INSTALLED INCLUDING PAPER TOWEL AND SOAP HORIZONTALLY. BOTTOM EDGE SHALL DISPENCERS BE AT 30" A.F.F. 14 _ _ _ _ _ - - 16 10 INSTALL TENANT FURNISHED TV do TV T.G.C. SHALL PROVIDE A 36'X36'X4'H - - BRACKET. SEE MANUFACTURER'S 21 CONC PAD FOR WATER HEATER. 110 11 I • INSTALLATION INSTRUCTIONS. VERIFY EXACT LOCATION WITH TENANT PRIOR 22 T.G.C. SHALL BE RESP. TO INSTALL TENANT MEN N TO INSTALLATION. SEE DETAIL 9/A7.3 SHELVING. SHELVING FURNISHED USPENDED L------J I 110 I C❑RR. Ij '-' PROVIDE 6" STUDS ® ELEC PNLS. do FROM SEE SHEETSA%5 SUSPENDED FROM UNDERSIDE OF COUNTER 1- _ _ _ _ -i \ 14 �, I ^ E C❑❑� R ao �i 11 RESTROOM WET WALLS ❑ SEE SHEET A5.1 FOR RESTROOM COUNTER \ 19 C 111 j 0o I FD t� PROVIDE ALARM PANIC HARDWARE AT 23 PLAN, SECTION AND FOR WALL FINISHES. ALSO 20 104 FD '0� — 12 THIS DOOR. HEET 1 SE R�ALUMNNUMSH STRIM SE /❑rJ RT -2 �',M,gCIH,' I"'❑❑� I—N� KITCHEN EXHAUST HOOD - SEE MECH 24 ANGCHEDULE x AT TOP EDGE OF I 13 SHEETS. HOOD WT. = 550 LBS. - MOP SINK. CAULK TO WALL C RTU-3 SUPPORT WITH ALL -THREAD UNISTRUT. PAINT GAS PIPES WHITE PT-5. ®° I EWC I I 21 I FROM STRUCT. ABOVE 25 14 I I I I ® T.G.C. SHALL PROVIDE FIRE TREATED '^=rr f.'r;`` •�°^.^•-• '.•_• i'f vT-`A�`' E E a I 14 WOOD BLOCKING ® ALL WALL MOUNTED .r , - - - - - - I I 14 I cu ITEMS SUCH AS TOILET ACCESSORIES, 14 0 �. HC I 16 kw WALL SHELVING, PAPER TOWEL F Fa I EWC - I DISPENSERS, ETC. AS WELL AS BEHIND r-i 27'-1' I I 19'-0 1/2'T 8IF O FD - - - - -B - \ n I I ^ 1--7r'^ I I I I I I I I i i U L- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -- L - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - J L - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1 A2.1 ARCHITECTURAL FLOOR SCALEt 1/4' = V-0' PLAN D WALL LEGEND EXISTING PARTITION TO REMAIN NEW NON -RATED PARTITION NEW 11HR RATED PARTITION I SYMBOL LEGEND ROOM NAME ❑FFICE 123 ROOM NUMBER 1XX = SUITE 100 2XX = SUITE 101 ROOM INF❑RMATION SYMBOL iBWINDOW LETTER SEE DETAILS AND FRAME ELEVATIONS ON SHEET A-3 WINDOW SYMBOL WALL TYPE LETTER - SEE SHEET A-4 F WALL TYPE SYMBOL DETAIL 7NUMBER 6 A-3 SHEET ON WHICH DETAIL IS SHOWN INTERIOR ELEVATI❑N SYMBOL DOOR NUMBER - SEE DOOR AND FRAME SCHEDULE ON SHEET A-3 101 DOOR SYMBOL SHEET ON WHICH DETAIL IS SHOWN DETAIL NUMBER CIRCLE AROUND AREA TO BE DETAILED 1 A-4 1 DETAIL SYMBOL 0 LO 0 o Q 8 U� O cV Nvi ad N co J 03 0. 0 U LL ' J o c c o > 0_ O N N ` co U C u? c U o Q to s d o J M J LL 0 .n Ua >� 0= 0 z 0 o g a' > c O N J =Q U C J O J L U c 0 r` 0 0 N 0 J J IT o NJi M w U O 0m J Of w � () W J 2 a U CL�_ WOMow N co N mow Revisions: J Z W H' 0 4 z 0 U -, LL oc F;; Project Number 07059 Date 02-28-08 Sheet Number A2.1 _ _ I _ - I - -- - - - ---L 1 A3,1 EQUIPMENT FLOOR PLAN SCALEI 1/4' = 1'-0' --------------- aD L — — — — — — — — — — — — — — — — — — — — -J --------------- FURNITURE AND EQUIPMENT SCHEDULE #1 NO. DESCRIPTION MANUFACTURER MODEL NO. SIZE WXDXH FURN. INSTALL VOLT PH HP AMP CONN. DRAIN CW* HW* GAS BTU REMARKS NO. DESCRIPTION MANUFACTURER MODEL NO. SIZE WxDxH FURN. INSTALLVOLT PH HP AMP CONN. DRAIN CW* HW* GAS BTU REMARKS i WIRE SHELVING ISS SHELVING VARIES TENANT G.C. 44 ICE TEA MAKER BUNN T6 17XI7X29 TENANT G.0 120 1 14.87 PLUG 1/4' 2 DUNNAGE RACK ALUM SPECIALIST VARIES TENANT G.C. 3 PORTABLE RACK NEW AGE INDUST, 6301 20 1/2X27 1/2X69 TENANT G.C. 46 CARBONATOR GENERIC COKE COKE 120 1/2' 4 WIRE SHELF (CUT TABLE) ISS SHELVING (2) 18 X 48 TENANT G,C, 51 CONVEYER OVEN LINCOLN 1600 75 1/4X 58 3/4 TENANT G.C. 120 1 14 PLUG/ EACH DECK 3/4 110000 EA 5 PIZZA PAN WALL RACKS --- --- --- TENANT G.C, 52 DOUGH MIXER HOBART P-660 27 1/2'X39 1/4' TENANT G.C. 208 3 2.5 8.6 DIRECT 6 UNDERCTR, SUSP, WIRE SHELF ISS SHELVING --- 2048 TENANT G.C. 53 PASTA COOKER FRYMASTER BBC 1SX32 3/4X49 TENANT G.C. 208 1 39 PLUG 3/8' 3/8 7 SYRUP RACK ISS SHELVING --- 1BX48 TENANT G.C. 54 DOUGH PRESS PROPROCESS CORP. DP-1100 17XIBX25 TENANT G.C. 120 1 12.5 PLUG 14 30' HEATED SHELF HATCO GRSB-30-F 17x30 1/2 TENANT G.C. 120 1 4,2 PLUG 55 COOLER KOLPAK CICI 7'-9'X14'-5 1/2'X8'-4' TENANT G.C. 230 1 1 DIRECT 15 18' HEATED SHELF HATCO GRSB-18-F 17x19 1/2 TENANT G.C. 120 1 2.8 PLUG CONDENSING UNIT KOLPAK PCL 145M TENANT G.C. 208 3 1 I/l 10.7 DIRECT 16 ILIGHTED FOOD GUARD HATCO --- 18x100 2 SALAD BAR TENANT G.C. 120 1 4.0 DIRECT EVAPORATOR COIL KOLPAK HM-145 TENANT G.C. 120 1 4.2 DIRECT 1' COPPER DRAIN 17 LIGHTED FOOD GUARD HATCO --- 18x54 8 PASTA BAR TENANT G.C. 120 1 2.5 DIRECT 61 WATER HEATER STATE SBN75-120 NE 2SX75 G.C. G.C. 120 1 DIRECT POP OFF TO 1' 1' 3/4 120000 18 LIGHTED FOOD GUARD HATCO --- 18x128 E WARMERS TENANT G.C. 208 1 13.6 DIRECT PROVIDE SEPARATE NEUTRAL FOR LIGHTS 62 CO2 TANK VENDOR G.C. 19 LIGHTED FOOD GUARD HATCO --- 18x105 8 WARMERS TENANT G.C. 208 1 12,4 DIRECT PROVIDE SEPARATE NEUTRAL FOR LIGHTS 71 P.O.S. REGISTER TENANT G.C. 120 1 2.0 PLUG 20 HOT FOOD WELLS APW/WYOTT HFW-4 WELL 58-1/2x23-7/16x56-7/8 TENANT G.C. 208 6 23.1 E.C. TO FURN & INST CORD CAPS. COPPER DRAINS W/SHUTOFFS 72 SAFE ROLLAND #2015 20'Hx15'Wx15'D TENANT G.C. 21 8' WORK TABLE (PREP) TABCO AG SERIES 30X96 TENANT G.C. 73 81 TIME CLOCK AMANO 3500 SERIES 8 1/4X10 1/2X6 TENANT G.C. 120 1 0,3 PLUG 22 6' WORK TABLE (STRETCH) TABOO SG SERIES 30X72 TENANT G.C. TYPE II OVEN HOOD MASTER AIR INC, CICI-A 9'-0'X6'-0'X2'-6' TENANT G.C. 120 1 2 DIRECT 23 7' WORK TABLE (CUT) TABCO AG SERIES 30X84 TENANT G.C. EXHAUST FAN SEE MECH. DWGS, --- --- --- --- --- -- --- --- --- 24 PIZZA MAKE TABLE DELFIELD 186114PTB 31.5 X 114 TENANT G.C. 120 1 3/4 14,0 PLUG SUPPLY FAN SEE MECH. DWGS. --- --- --- --- --- -- --- --- --- 25 4' HEATED SHELF HATCO GRSB-48-F 19X49 1/2 TENANT G.C, 120 1 6,4 PLUG 82 SPLASH GUARDS ADVANCE TABCO VARIES (COORD. WITH ADJACENT SINK DIMS.) TENANT G.C. --- -- --- --- --- 27 6' HEATED SHELF HATCO GRSB-72-F 1703 1/2 TENANT G.C. 120 1 9.4 PLUG 83 PAPER TOWEL DISPENSER TENANT G.C. SEE SHEET A3 28 SALAD DISPLAY UNIT (ROLL -IN) McCALL 93 1/8x34x34 TENANT G.C. 120 1 1/2 16.0 PLUG 84 TAKE OUT PIZZA WARMER FWE TS-1633-36 25,25x37,25x69 TENANT G.C. 120 1 2 11.3 PLUG 91 GAME TENANT G.C. 30 4' UNDERCOUNTER WARMER HATCO GRSB-48 19 1/2x48 TENANT G.C. 120 1 9.3 PLUG 92 COIN CHANGER TENANT G.C. 31 DISHWASHER & TABLE ECOLAB T.B.D. TENANT G.C. 1 3/4 PLUG 2' INDIRECT 3/4 EXTE D LEGS TO FULL HT. 93 WALL HUNG TRINKET MACHINE TENANT G.C. 32 3-COMPARTMENT SINK w/ PRE -RINSE (BOWL SIZE = 20'x20'x14.1 DRAIN BOARD SIZE (INTEGRAL) = 36'x27') ADVANCE TABCO 9-23-60-24RL 115X27 TENANT G.C. 2' INDIRECT 1/2' 1/2' 95 TELEVISION GENERIC 36' TENANT G.C. 120 1 3.0 PLUG INCL SUSP'N BRKT 97 DINING TABLE (4 TOP) TENANT G.C. 33 HAND SINK ADVANCE 7-PS-50 17 3/4 TENANT G.C. 1 1/2' DIRECT 1/2' 1/2' 98 DINING TABLE (2 TOP) TENANT G.C. 34 MOP SINK FIAT MSB 2424 24X24 G.C. G.C. 3' DIRECT 1/2' 1/211 101 BOOTH TABLE (4 TOP) TENANT G.C. 35 PREP SINK ADVANCE TABCO T9-21-20 40X24 TENANT G.C. 2' INDIRECT 1/2' 1/2' 103 BOOTH SEATING (SINGLE) TENANT G.C. 41 42 ICE MACHINE w/ REMOTE CONDENSING UNIT ICE MACHINE - SELF CONTAINED SCOTSMAN SCOTSMAN CME 506 /HTB 55 CME 656 42X31.5 TENANT TENANT G.C. G.C. 120 208 1 1 19 19 PLUG PLUG 1/2'INDIRECT 1/2'INDIRECT 3/8' 3/8' 104 BOOTH SEATING (DOUBLE) TENANT G.C. 105 106 WALL GRAPHICS MENU BOARDS TENANT TENANT G.C. G.C. 43 DRINK DISPENSER COKE DURAFLEX 250 30X3OX39 COKE COKE 120 ■ ALL WATER CONNECTUINS FROM STOP VALVE M EQUIPMENT SHALL BE WOVEN STEEL MESH FLEXIBLE LINES, C M M O LO :2 O 10 N a JN ad C U LL J 0 _Co a a N N fin C14 :3 U/ U ti 04 C t� U O Q O L a o Cl) J Cl) J LL CA 7 06 L N d L) ■ U) pL 0 00 Z. rn o c CD Q O 4) J C Z U C Q J O J M J I*- LL � U C f0 O O O N J > cC i o NW�i z N Q= JOB o ELmzi a U _ WoMow N CID N Revisions: Z CW nG Q —J in . V W O O J =Q � Project Number 07059 Date 02-28-08 Sheet Number All 12"x12"x1/4" CERAMIC TILE (CT-5) W/ BLACK EPDXY GROUT W/ 1/8" MAX. TILE JOINTS ON 5/16" CEMENTITIOUS TILE BACKER BOARD GLUED AND SCREWED TO 3/4" PLYWD. 1 x2 3/a" OAK TRIM WITH 1/2" CHAMFER OFFSET 1/8" BELOW TILE. RUN A ROUND -OVER BIT SULLNOSE TILE OVER CHAMFER. FINISH WOOD 0 EDGE -- W/ ST-1 STAIN & CLEAR --------------- JLnI-LI\ �VI"\III� 7/A3.2 lV2" W.R. GYP. BD. ON ALL ABV. DUROCK 1'-6' EDGES"OFATRAY WK TRIM ELL -1) ® 0D 1/ M RPFRP -1) LAM. PANEL (PL-2) N 1/2" PLYWOOD DUTRIM TO 12 A.F.F. LAM. PANEL (PL-2) 1STA NOAK GRADE CONT. CAULK _ b r.I FLOOR & BASE AS SCHEDULED 1 COUNTER SECTION AT TRAY A3.2 SCALES 3/4' = 1'-0' $ INDICATES PLACEMENT OF HOT FOOD WELL CONTROL SEE ELEC. DWGS .2 A3,2 PASTA/SOUP CUTOUT PLAN SCALE, 1 1/2' = 1'-0' CERAMIC TILE CT-5 ON 5/16" CEMENTITIOUS TILE BACKER BOARD GLUED AND SCREWED TO 2 LAYERS 3/4" PLYWD. — STAINLESS STEEL TRIM FURN. BY TENANT, INST. BY G.C. 2x WD. BLOCKING 01 4 SECTION AT HOT WELL A 3 . 2 SCALE, 1 1/2' = 1'-0' 12"x12"x1/4" CERAMIC TILE (CT-5) W/ BLACK EPDXY GROUT W/ 1/8" MAX TII F JONTS 1 1 /2"0 STAINLI STEEL SUPPORT POST BEYOND. 015 SUPPORT AT COUNTER A3.2 SCALES 1 1/2' = V-0' KNEEWALL OF ORDER COUNTER - REF. 2/A7.2 CONT. CAULK----`\ 6" THK. x 1'-8" x 2'-6" CONC. PAD FLOOR &BASE AS SCHED <— 3 BAR CONT. --� tTYP #3 REBAR CONT. 0 18" 6 CONC. PAD ��. SCALES 3/4' = V-0' 12p x12p x1/4 CERAMIC TILE (CT-5) W/ BLACK EPDXY GROUT (JOINTS 1/8- MAX.) ON Ya" MASTIC, ON N6" TILE BACKER BOARD. BULLNOSE TILE 0 EDGE TO MATCH CERAMIC TILE (CT-5) W/ BLACK EPDXY GROUT (JOINTS 1/8" MAX.). ADHERE TO PLYWOOD WITH CONSTRUCTION ADHESIVE PL2000. ,/7�BULLNOSE DETAIL A3.2 SCALES 3' = F-0' 12"02"x1/4" CERAMIC TILE (CT-5) W/ BLACK FINISHES ON FACE OF EPDXY GROUT W/ 1/8" SALAD AREA. MAX. TILE JOINTS 3'-4' 5/16" CEMENTITIOUS PIZZA BUFFET COUNTS TILE BACKER BOARD 3'-0 1/2' GLUED AND SCREWED 3 1/2' CUT OUT TO 3/4" PLYWD. 3'-4' TO WALL 1x2 �'a" OAK TRIM WITH FOOD V-10 1/8' 1/2" CHAMFER OFFSET GUARD 1/8" BELOW TILE. RUN 10EYOND o 0 A ROUND -OVER BIT OVER CHAMFER. FINISH WOOD W/ ST-1 STAIN AND CLEAR SEALER 0 (SATIN) BULLNOSE TILE0 �® EDGE a O Z aD ( C 7 A3.2 QF ST-1 SIM. cn* LAM. PANEL 5�8" W.R. GYP. BD. A V. DUROCK a ¢ ? J� 0 O °N° (PL-2) MARLITE FRP 00 o mi 1 /2" PLYWOOD (FRP-1) 20, GA MTL l= m m V I O I ;� „ 5/8 DUROCK BOARD 3 5L8" x 24 �� oA ���/// c� TO 12" A.F.F. STUDDS 0 KNEEWALL FRMG 1 1 /2 0 STAINLESS O STEEL SUPPORT POST BEYOND. ' ST-1 `� CONT. CAULK ?o TILE FLOOR & NO SLOPE 0 SALAD 8 AR Ww BASE AS SCHED. JmN 31 A3.2 NOTE! PAINT UNDER SIDE OF ALL COUNTERS & UNDER COUNTER BLOCKING PT-5 SECTION THRU SALAD BAR SCALE, 1 1/2' = V-0' K'8-' SALAD BAR PLAN A 3 � 2 SCALES 1/2' = V-0' 3 HEATED SHELVES TO BE INSTALLED EDGE TO EDGE. TGC SHALL INSTALL SUPPORT I IAIf1CMAlC AT" AC nr*^'/1 "9 ENLARGED EQUIPMENT PLAN A3.2 SCALES 1/2' = F-0' E T UT o � N N a n ao J C U ' JL (- o N � N Cl)N � C U ` Q o O r a 0 � J J 0 O Ua ._ U) 0 C Z 0 0 c O N J t U C Q J O J � LJL 06 U C 0 0 0 Y ! > W LV co J LL N UQ=� o CLmJ -_ �cMC- LLJ NCDN Revisions: J_ Q 0 z cW G D a W Project Number 07059 Date 02-28-08 Sheet Number A3.2 A I I I I I I I I — i I I I I I I I I I I 1 A4.1 REELECTED CEILING PLAN SCALES 1/4' = 1'-0' 8 REFLECTED CEILING LEGEND ® NEW OR RELOCATED SINGLE FACE ILLUMINATED EXIT SIGN - SEE ELECTRICAL DRAWINGS t> NEW OR RELOCATED BATTERY PACK EMERGENCY LIGHT FIXTURE - SEE ELECTRICAL DRAWINGS NEW OR RELOCATED 2'X4' LAY -IN FLUORESCENT LIGHT FIXTURE - SEE ELECTRICAL DRAWINGS NEW 2'X2' SURFACE MOUNTED FLUORESCENT LIGHT FIXTURE - SEE ELECTRICAL DRAWINGS ,.tom { } YO NEW CLG. MOUNTED FIXTURE NEW OR RELOCATED FIRE SPRINKLER HEAD SEE FIRE SPRINKLER DRAWINGS ® NEW SUPPPLY DIFFUSER - SEE MECH, DWGS. ® NEW RETURN GRILLE - SEE MECH, DWGS. ® NEW EXHAUST FAN - SEE MECH, DWGS, c ' o M `W u7 i+ 53 N�o c Q E � N N c C co otf T X Cl U c "> o o C a o N N ` 00 h N U Q 0� r �a o Cl) M J LL O 7 0 H N d ■ � Cl) O 0 O Z 00 C O � O O C � C U J C Q J n LJL 06 U O O 0 N N 0 UJ�It J > W W M J o N Q tt_ O -J m J w L) }. Q a W00UJ N co N Revisions: z Q a Z W Q � Q W fUt U� W U_ UJ Project Number 07059 Date 02-28-08 Sheet Number A4.1 I I I I: I 11 I I I f III '1'I I l' p III III I 1 I I I I I I I 0�1 WOMENS T❑ILET ROOM ENLARGED PLAN A5.1J SCALE11/2'=1'-0' WOMENS TOILET ROOM ELEVATION SCAM 1/2'=1'-O' ABRASIVE SURFACES UNDER LAV, WOMENS HANDICAPPED STALL ELEVATION SCAM 1/2'=1'-0' 4V SHALL BE ALL PIPES UNDER LAV SHALL BE RP EDGES OR INSULATED. NO SHARP EDGES OR UNDER LAV, ABRASIVE SURFACES UNDER LAV. 1 oo I I I In (u N OF DOOR 4 A5.1 MENS TOILET ROOM ENLARGED PLAN SCAM 1/2'=1'-0' MENS TOILET ROOM ELEVATION SCAM 1/2'=1'-O' ABRASIVE SURFACES UNDER LAV. MENS HANDICAPPED STALL ELEVATION SCAM 1/2'=11-0' OF DOOR FIG. 31 (FROM ADA & TAS) FIG. 32 (FROM ADA & TAS) 8"x 8" OPENING FOR TRASH RECEPTACLE BELOW. CER. TILE CT-5 ON EDGES OF OPENING. 2" x 2" x 3 16" CON T. STEEL SUPPORT ANGLE - 4 SIDES CER. TILE CT-5 ON 2 LAYERS 3/4" MARINE GRADE PLYWOOD. T❑ILET ROOM COUNTER PLAN SCALEI 1/2'=11-0' ACCESSABILITY NOTES WHILE IT IS THE INTENT OF THE ARCHITECT, HIS EMPLOYEES, AND ASSIGNS TO ADHERE TO ALL ASPECTS AND REGULATIONS OF THE AMERICANS WITH DISABILITIES ACT (ADA) AND LOCAL ACCESSABILITY CODES, THE CONTRACTOR SHALL NOT BE RELIEVED OF SOLE RESP❑NCIBILITY TO VERIFY ALL REQUIRMENTS OF SAID ACTS AS PERTAINING TO CONTRACT DOCUMENTS CONTAINED HEREIN PRIOR TO COMMENCEMENT OF ANY WORK, HE SHALL ALSO BE RESPONCIBLE TO IMMEDIATLY NOTIFY DESIGNER OF POSSIBLE DISCREPANCIES. HE SHALL ALSO PAY SPECIAL ATTENTION TO ITEMS LISTED BELOW.I 1, THE BOTTOM 10' OF ALL DOORS SHALL HAVE A SMOOTH UNINTERUPTED SURFACE TO ALLOW FOR DOOR TO BE OPENED BY A WHEELCHAIR FOOTREST, 2. NO THRESHOLD SHALL EXCEED J' IN HEIGHT. 3. HAND -OPERATED DOOR ❑PENING HARDWARE SHALL NOT REQUIRE TIGHT GRASPING OR TWISTING OF THE WRIST IN ORDER TO OPERATE, AND SHALL BE MOUNTED NO HIGHER THAN 48' A.F.F. 4. MAXIMUM FORCE REQUIRED TO OPEN EXTERIOR OR INTERIOR DOORS SHALL NOT EXCEED 5 LBS, 5. IF A DOOR HAS A CLOSER, THEN THE SWEEP PERIOD OF THE CLOSER SHALL BE ADJUSTED SO THAT FROM AN OPEN POSSITION OF 70 DEGREES, THE DOOR WILL TAKE AT LEAST 3 SECONDS TO MOVE TO A POINT 5 INCHES FROM THE LATCH, MEASURED TO THE LEADING EDGE OF THE DOOR, 6. LAVATORIES SHALL HAVE A MINIMUM KNEE CLEARANCE OF 29' FROM THE FLOOR TO THE BOTTOM EDGE OF THE APRON WITH A MINIMUM KNEE CLEARANCE OF 8' IN DEPTH X 30' IN WIDTH. TOE LEARANCE SHALL BE NO LESS THAN 17' DEEP FROM THE FRONT EDGE OF THE LAVATORY. 7. INSULATE OR COVER ALL PLUMBING UNDER LAVAT❑RIES S❑ THAT THERE ARE NO SHARP OR ABRASIVE SURFACES, 8. FAUCET CONTROL AND OPERATING MECHANISMS SHALL BE OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE TIGHT GRASPING, PINCHING OR TWISTING OF THE WRIST. THE FORCE REQUIRED TO ACTIVATE CONTROLS SHALL BE NO GREATER THAN 5LBS, LEVER OPERATED, FLUSH TYPE AND ELECTR❑NICALLY OPERATED MECHANISMS ARE EXAMPLES OF ACCEPTABLE DESIGNS, IF SELF CLOSING VALVES ARE USED, THE FAUCET SHALL REMAIN OPEN FOR A MINIMUM OF 10 SECOND, 9. FLUSH CONTROLS AT WATER CLOSETS AND URINALS SHALL BE OPERABLE AS FAUCET CONTROLS ARE IN #8 ABOVE, AND SHALL BE MOUNTED NO GREATER THAN 44' A.F.F. 10, PROVIDE SIGNAGE WITH INTERNATI❑NAL SYMBOL OF ACCESSABILITY IN ACCORDANCE WITH ANSI A117.1 (LATEST EDITI❑N) AND ADA REQUIRMENTS. 11. RESTR❑OM SINAGE SHALL BE MOUNTED ON THE WALL ADJACENT TO THE LATCH SIDE OF THE RESPECTIVE RESTROOM DOOR 60' TO CENTER LINE - MAX 1'-0' OFF LATCH SIDE OF DOOR OFF WALL. CER. TILE WALL FINISH. 2'-0" CER. TILE CT-5 ON 2 LAYERS 3/4" MARINE GRADE PLYWOOD. WITH BULLNOSE ON FRONT LIP & TRASH CAN CUT-OUT 70VIDE 2"x2"x1 /4" STL 6" 6" CONTINUOUS SCREWED W. IN. INTO STUDS 0 WALLS o o I I PROVIDE �4" THK �' z_' iu Fr 1 1 2" P. TRAP MARINE GRADE PLYWD. iu o C.O. PLUG "FIN" SUPPORT AT OPEN END OF COUNTER. INSTALL BLACK PLAS LAMINATE ON iu ALL SIDES AND EDGES. 8 TOILET ROOM COUNTER A5.1 SCALE13/4'=1'-0' TOILET ROOM NOTES+ 1. UNLESS ❑THERWISE NOTED, ALL ITEMS SHALL BE FURNISHED AND INSTALLED BY THE T.G.C. LAVAT❑RIES SHALL HAVE A MINIMUM CLEARANCE OF 29' FROM THE FLOOR TO THE BOTTOM EDGE OF THE APRON WITH A MINIMUM KNEE CLEARANCE OF 8' IN DEPTH BY 30' IN WIDTH, 2. TOE CLEARANCE SHALL BE NO LESS THAN 17' DEEP FROM THE FRONT EDGE OF THE LAVATORY. 3. ALL PLUMBING UNDER LAVATORIES SHALL BE INSULATED OR COVERED S❑ THERE ARE NO SHARP OR ABRASIVE SURFACES PER ADA, 4. FAUCET CONTROL AND OPERATING MECHANISMS SHALL BE OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE TIGHT GRASPING, PINCHING, OR TWISTING OF THE WRIST. THE FORCE REQUIRED TO ACTIVATE CONTROLS SHALL BE NO GREATER THAN 5 LBS, LEVER OPERATED, FLUSH TYPE AND ELECTRONICALLY OPERATED MECHANISMS ARE EXAMPLES OF ACCEPTABLE DESIGNS. IF SELF-CL❑SING VALVES ARE USED, THE FAUCET SHALL REMAIN OPEN FOR A MINIMUM OF 10 SECONDS, 5. FLUSH CONTROLS AT WATER CLOSETS AND URINALS SHALL BE OPERABLE AS FAUCET CONTROLS ARE IN NOTE #4 ABOVE AND SHALL BE MOUNTED NO HIGHER THAN 44' A.F.F. FLUSH CONTROLS SHALL ALSO BE LOCATED TOWARD THE OPEN SIDE OF THE STALL. ONLY FLUSH VALVE WATER CLOSETS WILL BE ACCEPTABLE. 6, ADJUST TOILET PARTITION DOORS TO STAND OPEN 6' FROM PILASTER SUPPORTS WHEN COMPARTMENT IS UN❑CCUPIED, 7. GRAB BARS TO BE 1 1/2' IN DIAMETER AND INSTALLED NO MORE THAN 1 1/2' FROM WALLTO EDGE OF BAR. GRAB BARS MUST BE ABLE TO WITHSTAND A 250 LBS, FORCE AND HAVE NO SHARP OR ABRASIVE EDGES, 8. CLEAR FLOOR SPACE OF 30X48 SHALL BE MAINTAINED AT ALL CONTROL AND OPERATING MECHANISMS. (E.G., PAPER TOWEL DISPENSER). SEE ELEVS, OR ACCESSORY SCHED, FOR ACCESSIBLE MOUNTING HEIGHTS. ACCESSORY NOTESi 1. GRAB BARS SHALL BE PROVIDED PER FEDERAL ADA REQUIREMENTS AND FLORIDA BOARD OF BUILDING CODES AND STANDARDS ACCESSIBILITY REQUIREMENTS. GRAB BARS SHALL BE LOCATED 33' ABOVE FINISHED FLOOR, SHALL HAVE AN ❑UTSIDE DIAMETER OF 1 1/2', AND SHALL PROVIDE 1 1/2' OF CLEARANCE BETWEEN THE RAIL AND THE WALL, GRAB BARS SHALL BE SO DESIGNED AND SUPPORTED AS TO WITHSTAND A LOAD OF NOT LESS THAN 250 POUNDS APPLIED AT ANY POINT, DOWNWARD OR HORIZONTALLY. GRAB BAR BEHIND TOILET SHALL BE 36' LONG, GRAB BAR AT SIDE WALL SHALL BE 42' LONG, 12' FROM BACK WALL, 2. MEN'S ROOM DOOR SHALL HAVE MALE SYMBOL AND HANDICAPPED SYMBOL, WOMEN'S ROOM DOOR SHALL HAVE FEMALE SYMBOL AND HANDICAPPED SYMBOL. UNISEX ROOM DOOR SHALL HAVE UNISEX SYMBOL AND HANDICAPPED SYMBOL, GENERAL NOTESi 1, DIMENSIONS ARE TO CENTER OF STUD UNLESS OTHERWISE NOTED, 2. ACCESSORIES ARE BASED ON BOBRICK. 4. FOR PLUMBING FIXTURE SPECIFICATIONS AND NOTES, SEE PLUMBING DRAWINGS. 5, MIRRORS TO BE 1/4' QUALITY q2 CLEAR FLOAT GLASS WITH FULL SILVER, COPPER AND ORGANIC COATINGS. PROVIDE UNIFORMLY GROUND AND POLISHED EDGES, ACCESSORY SCHEDULE ITEM MODEL # MOUNTING O1 TISSUE DISPENSER B-2740 SURFACE @ 21' A.F.F. @ CNTR. SANITARY NAPKIN O DISPOSAL, SURFACE MOUNTED (WOMEN ONLY) 3A PAPER TOWEL DISPENSER & WASTE RECEPT- B-3944 RECESSED @ 40' A.F.F. @ ❑PN'G. ACLE, RECESSED MOUNTED PAPER TOWEL DISPENSER 3B & WASTE RECEPT- ACLE, SURFACE MOUNTED DISPENSER, OSOAP RECESSED MOUNTED B-306 SURFACE @ 40' A.F.F. @ VALVE O5 MIRROR SURFACE O DOUBLE HOOK SURFACE @ 62' A.F.F. @ CNTR. GRAB BARS - 36' LONG B-6206 SURFACE - SEE ACCESSORY NOTE #1. l� SERIES 7B GRAB BARS - 42' LONG B-6206 SURFACE - SEE ACCESSORY NOTE #1. SERIES O8 DOOR SIGNS - SEE NOTE #2 SURFACE - OUTSIDE OF DOOR UNISEX HEVVI 710.150ASK #8 BLACK MALE SYMBOL HEVVI 710.150.1SK #8 BLACK FEMALE SYMBOL HEVVI 710.150.2SK #8 BLACK HANDICAPPED SYMBOL HEVVI 710.150.3SK #8 BLACK O9 OVERHEAD BRACED TOILET COLOR MARLITE HIGH PRESSURE AND URINAL PARTITIONS #1595-60 FLOOR MOUNTED. E T UT CM C_ J" co o�j co U LL C J> m m 0 N N 3 � UI U ; C rcli o a 0 a 0 � J J LL 0 .o U! a� OL U .`�J W M O r Go o z Go c to > O N J C M C J O � J OJ L U .. O C ^5 > O 0 0 N � > W UJ co J o N Q?� 0 � � m J w W ow N(DN Revisions: G U) O (J 00 w F- Q = m (LJ U) J cw W z L.L. Z U) J J W a.0 z Project Number 07059 Date 02-28-08 Sheet Number A5.1 5/8' GYPSUM WALL BOARD ON 3-5/8' 20 GA METAL STUDS (TYPE 'X' AT 1-HOUR RATED WALLS) 3 5/8' 20 GA RUNNER CHANNEL (TURN UP @ STUDS) SEALANT, TYPICAL HOLLOW METAL FRAME 1 15/16' 2" 1 15/16' —4---5 7/8" 1 DOOR HEAD A61 SCALES 3'=1'-O' 5/8' GYPSUM WALL BOARD (TYPE 'X' AT 1-HOUR RATED WALLS) 3 5/8' 20 GA METAL STUDS 1 SEALANT, TYPICAL HOLLOW METAL FRAME (WITH STANDARD ANCHOR) Z DOOR JAMB A6.1 SCAM 31=1'-0' 2 •d d° Al-d d d V.C.T, OR RESILIENT SHEET FLOORING NOTES TRANSITIONS MUST MEET REQ, FOR MAXIMUM HEIGHT & SLOPE PER A.D.A. REQUIREMENTS VINYL TILE/SHEETING REDUCER CARPETING V,C.T. OR RESILIENT SHEET FLOORING VINYL EDGE TRIM MARBLE THRESHOLD CERAMIC TILE V.C.T., RESILIENT SHEET FLOORING OR CARPETING INTERIOR DOOR THRESHOLDS SCAM 6'-1'-0' 1/ 5/8' GYPSUM WALL BOARD ON 3-5/8' 20 GA METAL STUDS (TYPE 'X' AT 1-HOUR RATED WALLS) 3 5/8' 20 GA RUNNER CHANNEL (TURN UP @ STUDS) SEALANT, TYPICAL HOLLOW METAL FRAME 5 7/8' 4 DOOR HEAD A6,1 SCALEi T=1'-0' 5/8' GYPSUM.WALL BOARD (TYPE 'X' AT 1-HOUR RATED WALLS) 3 5/8' 20 GA METAL STUDS SEALANT, TYPICAL HOLLOW METAL FRAME <WITH STANDARD ANCHOR) K'5'* D00R JAMB A6,1 SCALES 3'=1'-0' GENERAL NOTES 1. INTERIOR HOLLOW METAL DOOR FRAMES SHALL BE 18 GA COLD ROLLED STEEL, KNOCK DOWN TYPE WITH RESILIENT BUMPERS. FRAME SHALL BE FACTORY PRIMED AND PAINTED BLACK COIL BASED AND SEMI -GLOSS.) PROVIDE MINIMUM 4 - 18 GA ANCHORS PER JAMB, WELD TO EACH FRAME, 2. DOOR AND HARDWARE SOURCEi RDL SUPPLY (214) 630-3965 3. ALL INTERIOR D❑O HARDWARE SHALL HAVE BRUSHED ALUMINUM FINISHES. 4. ALL LOCKSETS & LATCH SETS SHALL BE LEVER STYLE, TO MEET ADA REQUIREMENTS APPROVED & MEET ALL REQUIRMENTS OF THE FLORIDA ACCESSABILITY CODES, 5. BOTH SIDES OF ALL DOORS SHALL HAVE THE SAME ELEVATION WITH NO MORE THAN 1/2' DIFFERENCE ON EACH SIDE. 6. PROVIDE PANIC EXIST DEVISE & ASSOCIATED HARDWARE AS REQUIRED BY THE FLORIDA BUILDING CODE, 7. PANIC HARDWARE TO HAVE AUDIBLE ALARM, 8, PANIC ALARM HARDWARE SHALL BE DETEX #V40xEB WITH FULL WODTH CRASH BAR, PADDLE HARDWARE WILL NOT BE ACCEPTED, 9. PANIC HARDWARE FOR STOREFRONT SHALL BE DETEX VALUE SERIES V400lxHDx7ll - BLACK. (STOREFRONT DOORS WITH 2' STILES ALSO REQUIRE THE NARROW STYLE DOOR KIT # 101879-2.) DOOR AND FRAME SPECIFICATIONS AB. MATERIAL MANUFACTURER NOTES AG ALUMINUM & GLASS - HM HOLLOW METAL SC PC PARTICLE CORE DOOR HALEY ARCHITECTURAL DOORS. PARTICLE CORE CONSTR., BIRCH VENEER FACE COLOR = 'REGENCY' STL STEEL PC DA DOUBLE ACTING DOOR ELIASON LWP-3 DOOR & FRAME SPECIFICATIONS AG = ALUMINUM & GLASS HM = HOLLOW METAL SC = SOLID CORE WOOD PC = PARTICLE CORE WOOD WD = WOOD PH = PREHUNG WOOD STL = STEEL FINISHES FF = FACTORY FINISH P = PAINT ESP = ELECTR❑STATIC PAINT SV = STAIN/VARNISH GLASS Gl = 1/4' FLOAT G2 = 1/4' TEMPERED CLEAR G3 = FIRELITE GLAZING HARDWARE NOTES H1 EXISTING, RE -KEY ALIKE H2 MATCH EXISTING, RE -KEY ALIKE H3 1 1/2' PR BUTTS, DOOR STOP, KICK PLATE (PER LEAF) PROVIDE FLUSH BOLTS IN FIRST LEAF AND LOCKSET IN SECOND LEAF. VERIFY WITH OPERABLE TENANT, H4 1 1/2' PR BUTTS, LOCKSET, DOOR STOP, KICK PLATE H5 1 1/2' PR BUTTS, PUSH/PULL, DOOR CLOSER, DOOR STOP, KICK PLATE & SILENCERS H6 PANIC DEVICE WITH AUDIBLE ALARM, RE -KEY ALIKEI DOOR VIEWER DU SEVING OOR SCOPE LOCATE AT 4'-6' A.F. (CONTACTi DU SEUNG TRADING CO. @ 1-800-274-SCOPE), DOOR CLOSER H7 MANUFACTURER PACKAGES HS ALL HARDWARE TO BE LEVER HANDLED TO MEET REQUIREMENTS OF A.D.A. AND FLORIDA ACCESSIBILITY CODES, H9 BOTH SIDES OF ALL DOORS SHALL HAVE THE SAME ELEVATION WITH NO MORE THAN 1/2' DIFFERENCE ON EACH SIDE. HIO PROVIDE PANIC EXIT DEVICE & ASSOCIATED HARDWARE AS REQUIRED BY THE FLORIDA BUILDING CODE, Hll T,G.C. TO PROVIDE PANIC HARDWARE, H12 INSTALL CODE APPROVED HANDICAP SIGNAGE. H13 UNDERCUT DOOR 1' DOOR AND FRAME SCHEDULE NO SIZE DOOR GLASS RATING HARDWARE NOTES FRAME REMARKS TYPE MAT, FIN. TYPE MAT, FIN. 100A 3'-0' X 7'-0' - - - - - H1,Hll - - - EXISTING STOREFRONT ENTRANCE 100B 3'-0' X 7'-0' - - - - - H1,Hll - - - EXISTING STOREFRONT ENTRANCE 105 3'-0' X 7'-0' SP PC SV - - H7,H8,H9 B HM SV - 107 3'-0' X 7'-0' - - - - - H1,H8,I49,Hll - - - EXISTING STOREFRONT ENTRANCE 109 3'-0' X 7'-0' FL PC SV - - H5,H8,H9,H12,H13 A HM SV - 110 3'-0' X 7'-0' FL PC SV - - H5,HB,H9,H12,H13 A HM SV - ill 3'-0' X 7'-0' - - - - - Hl,H10,Hll - - - EXISTING DOOR TYPES SCALEt 1/4'=1'-0.1 O SPECIAL FLUSH WOOD W/ SP STAIN GRADE VENEER FL (DOOR FRAME TYPES SCALEi 1/4'=l'-O' 1 ri 0 M CD ( Q 0 0 a c E U- o y � N N C] C N CID x rn _ > JU_ o � n w 0 N ` 0N � U c o a O s a 0 M JM ..J LL 0 Ua O r_ LID oCD Z o > O N J C c C J O a J O J r- LJL 0 0 P_ 0 0 N 0 J 0 LO o N W JJ M U_ N UQ = L- O m J ry J = w H () �QQ! a W 00 W NWN Revisions: U) J_ Q LU 06 00 O W ❑ _j 0 ❑ W U Project Number 07059 Date 02-28-08 Sheet Number A6.1 5/8' VENEER GYPSUM WALL BOARD (BLUE BOARD) ON 7/8' METAL FURRING CHANNELS FINISHES - SEE SCHEDULE SUSPENDED ACOUTICAL CEILING 1/8' GYPSUM WALL BOARD MASONRY BATT INSUL. (R5.6) SEALANT 1 EXTERIOR WALL TYPE "A" A7,1 I SCALEt 3'=1'-0' Z EXTERIOR WALL 7.1 J SCALES 3'=1'-0' METAL RUNNER FINISHES - SEE SCHEDULE SUSPENDED ACOUTICAL CEILING 5/8' VENEER GYPSUM WALL BOARD (BLUE BOARD) ON 7/8' METAL FURRING CHANNELS 1/8' GYPSUM PLASTER VENEER MASONRY BATT INSUL, (R5.6) METAL RUNNER SEALANT TYPE "B" UNDERSIDE OF ROOF OR FLOOR DECK 1/4' CONT, SEALANT METAL RUNNER 3-5/8' METAL STUDS @ 24' O,C, MAX. SUSPENDED ACOUTICAL CEILING FINISHES - SEE SCHEDULE 5/8' TYPE 'X' GYPSUM WALL BOARD ON BOTH SIDES (COPE TOP TO DECK PROFILE) 3-1/2' SOUND ATTENUATION INSULATION METAL RUNNER SEALANT ONE HOUR PARTITION TYPE "C" SCALES 3'=1'-O' UNDERSIDE OF ROOF OR FLOOR DECK 1/4' CONT, SEALANT METAL RUNNER 3-5/8' METAL STUDS @ 24' ❑,C, MAX. SUSPENDED ACOUTICAL CEILING FINISHES - SEE SCHEDULE 5/8' TYPE 'X' GYPSUM WALL BOARD ON BOTH SIDES (COPE TOP TO DECK PR❑FILE) 3-1/2' SOUND ATTENUATION INSULATION METAL RUNNER SEALANT U.L. DESIGN U-465 ONE HOUR PARTITION TYPE "D" SCALEi 3'=1'-0' UNDERSIDE OF STRUCT, METAL RUNNER 3-5/8' METAL STUDS @ 24' ❑.C, MAX, FINISHES - SEE SCHEDULE SUSPENDED ACOUSTICAL CEILING 5/8' GYPSUM WALL BOARD ON BOTH SIDES (M.R, BOARD ON TOILET ROOM SIDE) 3-1/2' SOUND INSULATION WHERE SHOWN ON PLAN METAL RUNNER 1/4' CONT. SEALANT INTERIOR PARTITION TYPE "E" SCALES 3'=1'-O' UNDERSIDE OF STRUCT, METAL RUNNER 6' METAL STUDS @ 24' ❑,C. MAX. FINISHES - SEE SCHEDULE SUSPENDED ACOUSTICAL CEILING 5/8' GYPSUM WALL BOARD ON BOTH SIDES MR. BOARD ON TOILET ROOM SIDE) 5-1/2' SOUND INSULATION WHERE SHOWN ON PLAN METAL RUNNER 1/4' CONT. SEALANT INTERIOR PARTITION TYPE "F" SCALES 3'=1'-C' :R 3EE L STUDS @ WALL 1TH SIDES :R EALANT MATERIAL SCHEDULE MARK DESCRIPTION MANUFACTURER REFERENCE NO. SIZE COLOR REMARKS CT-2 CERAMIC TILE DAL -TILE PERMATONE SERIES #6547 2'X2' MATTE MUSTARD GROUTt LATICRETE WALL GROUT, #23 ANTIQUE WHITE, NON -SANDED CT-3 CERAMIC TILE REFIN #RN901 12'X12' CUT TO 6'X6' BLACK MATTE FINISH GROUTi BLACK EPDXY (1/8' JOINT MAX) - TILES FOR FACE OF BUFFET CT-4 CERAMIC TILE AMERICAN TILE #RN901 13'X13' SIERRA MADRE - CAFE GROUT, MAPLLE #47 CHARCOAL, SANDED BULLNOSE AMERICAN TILE #RN901 13'X13" SIERRA MADRE - CAFE CUT 3'X13' FOR CHAIR STOP, THRESHOLD AT GAME ROOM AND TILE CAP IN THE RESTROOM CT-5 CERAMIC TILE REFIN #RN901 12'X12' BLACK MATTE FINISH GROUT, BLACK EPDXY (1/8' JOINT MAX) - TILES FOR FACE OF BUFFET QT-1 QUARRY TILE DAL -TILE SURE TREAD 6'X6'Xl/2' 0076 GRAY GROUT, MAPEL #47 CHARCOAL SANDED M*x ALTERNATE METRO -TREAD 6'X6'Xl/2' MT 57T PURITAN GRAY - QB-1 QUARRY TILE BASE DAL -TILE SURE TREAD 6'X6' 0076 GRAY GROUTi MAPEL #47 CHARCOAL SANDED - TO MATCH QT-1 ABOVE COVE BASE VB VINYL COVE BASE _ = 4' OR 6' X 1/8' BLACK (REF, SECTIONS) ADHESIVE, S725 WALL BASE ACT-1 LAY -IN ACOUSTICAL TILE ARMSTRONG MINIBOARD CORTEGA 2'X2'X5/8' WHITE #770B PATTERNt RANDOM FISSURED wx* ALTERNATE CELOTEX NO, BETA 157 BAROQUE 2'X2'X5/8' WHITE - ACT-2 LAY -IN VINYL CLAD GYP. BOARD GOLD -BOND GRIDSTONE 2'x4'xl/2' WHITE - ww* ALTERNATE CELOTEX - FRP-1 FRP PANELS MARLITE FRP SERIES P-100 - WHITE, PEBBLEST❑NE PROVIDE 1-1/2' X 1-1/2' HEAVY DUTY CORNER GUARDS AT ALL OUTSIDE FRP CORNERS, WHITE P-1 PAINT SHERWIN WILLIAMS PROMAR 200 INTERIOR LATEX ENAMEL - #SW1165 SUBTLE SAGE EG-SHELL FUNUSH (BOTTOM OF FURR DOWNS) P-2 PAINT SHERWIN WILLIAMS PROMAR 200 INTERIOR LATEX ENAMEL - #SW6683, BEE, SEMI GLOSS - P-3 PAINT SHERWIN WILLIAMS INTERIOR ALKYD - #SW1007 BLACK, SEMI GLOSS COLOR FOR ALL INTERIOR DOOR FRAMES AND EXPOSED COLUMNS P-4 PAINT SHERWIN WILLIAMS INTERIOR LATEX ENAMEL - SW1166 OLIVE DRAB, SEMI GLOSS - P-5 PAINT SHERWIN WILLIAMS INTERIOR ALKYD - SW6385 DOVER WHITE, SEMI GLOSS - ST-1 STAIN MINWAX - - RED OAK STAIN W/ CLEA SATIN SHEEN - SC-1 PAINTED CONCRETE RUST-O-LEUM EPDXY SHIELD GARAGE FLOOR COATING 2 PART SOLVENT BASED EPDXY TAN - SEMI GLOSS APPLY EPDXY SHIELD CLEAR COATING SEALER PL-1 PLASTIC LAMINATE MELAMINE - - WHITE SC-1 PLASTIC LAMINATE WILSONART #4798-60 - BURNISHED EMBER, MATTE FINISH NOTE, VERIFY ALL FINISHES, COLORS AND PATTERNS WITH TENANT ROOM FINISH SCHEDULE RM # ROOM TYPES FLOOR BASE WALLS CEILINGS REMARKS MATL, COMMENT MATL, HGT, COMMENT 100 ENTRY CT-4 CT-4 PT-4 ABOVE PL, LAM. WAINSCOT ACT-1 10'-0' REFER TO FINISH NOTE #4 101 ORDER QT-1 QB-1 PT-4 ABOVE PL. LAM, WAINSCOT @ SIDE WALL PT-2 9'-0' - PT-4 @ REAR WALLL ABOVE TILE WAINSCOT PT-2 @ FURR DR FACE 102 DISPLAY KITCHEN QT-1 QB-1 CT-2 ON SERVING SIDE OF WALL PT-2 6'-11' ON FURR, DN ACT-1 10'-0' @ MAIN CLG, 103 SERVING CT-4 CT-4 PT-1 @ BOTTOM OF FURR DN, ACT-1 10'-0' REFER TO FINISH NOTE #4 CT-5 @ COUNTER 104 PIZZA PREP QT-i QB-1 FRP-i - ACT-2 9'-4' - PREP KITCHEN QT-1 QB-1 FRP-1 - ACT-2 9'-4' 105 COOLER QT-1 - - PRE-FAB COOLER WALLS ACT-2 9'-4' - 106 BEVERAGE STATION CT-4 CT-4 CT-5 ON WALL AND COUNTER ACT-1 10'-0' SEE 8/A73 107 DINING CT-4 CT-4 PT-2 ABOVE CHAIRAIL ACT-1 10'-0' - PT-4 BELOW CHAIRAIL 108 GAME ROOM SC-1 VB PT-4 - ACT-1 10'-0' REFER TO FINISH NOTE #4, 5, & 8 109 WOMEN CT-4 CT-4 PT-5 ABOVE CT-4 WAINSCOT ACT-2 9'-0' SEE SHEET A5.1 110 MEN CT-4 CT-4 PT-5 ABOVE CT-4 WAINSCOT ACT-2 9'-0' SEE SHEET A5,1 ill CORRIDOR CT-4 CT-4 PT-2 ABOVE CHAIRAIL ACT-2 9'-0' PT-4 BELOW CHAIRAIL MAXIMUM ALLOWABLE HEIGHT OF INTERIOR NON -BEARING METAL STUD WALLS BASED ON DIETRICH STEEL STUDS CRITERIAr LATERAL LOAD = 5 PSF MAXIMUM ALLOWABLE DEFLECTION = L/240 1 LAYER (MIN.) GYPSUM BD, EACH FACE FULL HEIGHT STUD MAXIMUM HEIGHT PER STUD SPACING SIZE STYLE GAUGE 12' 16' 24' 2 1/2 STN 25 11'-11' 11'-3' 10'-7' 2 1/2 STE 20 DW 13'-2' 12'-1' 101-9' 2 1/2 STX 20 STR 13'-11' 12'-10' 11'-7' 3 5/8 STN 25 15'-4' 14'-4' 13'-5' 3 5/8 STE 20 DW 17'-i' 15'-8' 14'-0' 3 5/8 STX 20 STR 17'-10' 16'-5' 14'-9' 4 STN 25 16'-5' 15'-4' 14'-2' 4 STE 20 DW 19'-0' 17'-6' 15'-7' 4 STX 20 STR 19'-11' 18'-4' 16'-5' 6 STN 25 22'-1' 19'-9' 16'-9' 6 STE 20 DW 25'-6' 23'-2' 20'-3' 6 STX 20 STR 26'-9' 24'-6' 21'-7' 20 DW GAUGE = 30 MILS, 20 STR GAUGE = 33 MILS FINISH NOTES FINISH NOTES 1. TAPE, BED, FLOAT & SAND GYP, BD. JOINTS. FINISH TO A LIGHT ROLLED TEXTURE AT ALL PAINTED AREAS (FINISH ON FURR DOWN WILL REMAIN SMOOTH FOR WALL GRAPHIC.) PAINT ONE COAT OF PRIMER AND TWO COATS OF COLOR. 2. CHANGES IN LEVEL UP TO 1/4' BETWEEN DIFFERENT FLOOR FINISHES CAN BE MADE VERTICAL AND WITHOUT EDGE TREATMENT, CHANGES IN LEVEL OF 1/4'-1/2' SHALL BE MADE WITH BEVELED TRANSITION OR OTHER MATERIAL WITH A SLOPE NO GREATER THAN 1i2, CHANGES IN LEVEL GREATER THAN SHALL BE ACCOMPLISHED BY MEANS OF A RAMP, 3. WHERE CERAMIC TILE BASE IS SHOWN, T.G,C, SHALL CUT TILES TO 6' HT. 4. REFER TO WALL SECTIONS AND DETAILS FOR FINISHES AT WAINSCOT, LOW WALLS AND SERVING COUNTER, 5. T,G.C. SHALL VERIFY WITH TENANT THE EXACT PLACEMENT OF WAINSCOTING AND WHERE ONLY PAINT IS REQUIRED FOR GAME ROOM WALLS. 6. REFERENCE 'CICI'S PIZZA' WHEN ORDERING ANY CROSSVILLE TILE PRODUCTS, 7. ALL OAK TRIM SHALL BE CAULKED TO ADJACENT MATERIALS. B. T.G.C, SHALL FURNISH AND INSTALL A RUBBER 'HALF SADDLE' REDUCE STRIP WHERE SEALED CONC, MEETS ANY TILE FLOORING MATERIAL. THIS SHALL BE SET IN A CONTINUOUS BED OF BUTYL RUBBER CEMENT (100% COVERAGE), WILSONART LAMINATE CONTACTi TERESA HUMPHREY (214) 634-2310 DAL -TILE CONTACT, PETER BOIDOCK (800) 486-5724 AMERICAN TILE CONTACTi SCOTT ROWE (972) 280-0175 REFIN CONTACTi SC❑TT ROWE (972) 280-0175 NOTEi T.G.C. SHALL INSTALL 1'Xl'Xb' CLEAR PLASTIC CORNER GUARDS ON ALL OUTSIDE CORNERS TO 7' A.F.F. WHERE PAINT IS THE FINISH (I.E. HALL AND GAME ROOM ENTRIES), CORNER GUARDS ARE TO BE ATTACHED W/ FINISH SCREWS (NO ADHESIVE / GLUE). N 5 M o LO J .a o N c� oa 0 8 U� rn 8 � N N C co 0 x CM V _ > J� � N a o m ti ai C a O= n o I-- J M U_ 06 a0 Ua ' o O U) o Z o0 0 L,Vi Q > o ci � tq J Op� Q U C J J 1- U. U C N 0 0 0 N O J LO C,) � Ww J o N Q=LL J p m Cl)O ,J LU () Z Q UJ CO N co UJ N Revisions: 0QH -J W O O UJ Z 06 W N 4 J o M QUJ Q z = Project Number 07059 Date 02-28-08 Sheet Number A7.1 II 1 11 II__1 1 ALL CEILING AREAS SHALL RECEIVE 6" UNFACED INSULATION BAT`TS - R-19. W�.S�Q 10'-0" A.F.F. 2x2 LAY -IN CEIL'G TILE do GRID 2 LAYERS 5/8" TYPE 'X' GYP. BO. (PAINT PT-4) SEAL TIGHT TO DECK do FIRE CAULK — FIRE -RATED DEMISING WALL ENTRY 101 2x2" OAK TRIM WITH 1/2" CHAMFER OFFSET ALIGN WITH COUNTER TRIM. FINISH WOOD W/ ST-1 STAIN do CLEAR SEALER (SATIN) 1x2 W OAK TRIM WITH - 1/2' CHAMFER OFFSET. FINISH WOOD W/ ST-1 STAIN do CLEAR SEALER (SATIN) COUNTER BEYOND LAM. PANEL (PL-2) CONT. CAULK TILE BASE - TILE FLOOR - AS SCHEDULED 1/4" MAX. j T.G.C. TO CAULK JOINT BETWEEN io WOOD TRIM AND TILE COUNTER .71 WITH 100% CLEAR SILICONE. 11 AAATru I wr - CArr nc 1x2 3/4 OAK TRIM WITH 1/2- CHAMFER OFFSET 1 /8" \ BELOW TILE. FINISH WOOD W/ ST-1 STAIN AND CLEAR SEALER (SATIN) N 3 1/ 3 /8" MTL STUDS 0 = KNEEIEWALL FRMG. --�- 5/8" W.R. GYP. BD. o ABOVE DUROCK j I MARLITE FRP(FRP-1)- C4 N 1/2- PLYWOOD -'-'- CERAMIC TILE (CT-5) CUT TO MAKE 6" x 6" TILES io BFLRIOO& ASE -`-- V-7 3/4" NOTE! PAINT UNDER SIDE OF ALL COUNTERS & UNDER COUNTER BLOCKING PT-5 5/16" CEMENTIMOUS TILE BACKER BOARD GLUED AND SCREWED TO 2 (TWO) LAYERS 3/4" PLYWD. .12"x12"x1 /4" CERAMIC TILE (CT-5) W/ BLACK EPDXY GROUT W/ 1/8" MAX. TILE JOINTS 1 1/2" x 1 1/2" x 3/16" CONT. MECHANICALLY SUPPORTANGLE ATTACHED TO POSTS BULLNOSE TILE 0 EDGE N PR VIDE 10" VALANCE (3 4" PLYWD) FOR 0 IN T'N OF PASTA WELL CONTROLS SEE ELEV. P-LAM (PL-2) -CHAMFER BOTT. EDGE OF VALANCE 1/8" DROP -IN HOT WALLS & CONTROLS FURN D BY TEN. INST'D BY --��5/8" DUROCTG.C. TO 12" A.F.F.K 1 1/2"0 STAINLESS STEEL I —I ON WET SIDE l\--SUPPORT POST - ANCHOR TO SLAB W/ EXPANSION BOLTS & PLATE - PROVIDE SEALANT AT ALL EDGES GANG DRAIN LINES TOGETHER TO ONE DROP HUB DRAIN HOLD ALL HORIZONTAL LINES AS TIGHT TO UNDERSIDE OF PANS AS POSSIBLE. 3 COUNTER SECTION A % 2 SCALD 3/4' = V-0' SEE FINISH SCHEDULE 2" 0 x 4'L. GALV. POSTS CORE DRILL 12" INTO SLAB & CEMENT INTO PLACE. SECURE STUDS TO / C-4�� POSTS FOR WALL SUPPORT. POSTS TO BE GALV. FENCE POSTS 0 4'-0" O/C CONT. BASE AS SCHED. 4'-0' 1 4'-0' 1 'EXIST. SLAB 6 PARTIAL LOW WALL ELEVATION A7.2 SCALEi 1/4' = V-0' 5 1/2' 1 x 6 OAK CAP ST-1 & CLEAR SEALER (SATIN) 1x 6 OAK CAP ST-1 & CLEAR SEALER (SATIN) BLOCKING AS REQ'D 1 WALL SECTION AT ENTRY 7 OAK CAP DETAIL A 7, 2 SCALES 3/4' = 1'-0' A 7 2 SCALE, 1 1/2' = 1'-0' VERTICAL FRMG TO STRUCT FRAMING AT PERIMETER OF SOFFIT SHALL BE iu 7/A7.2 NOTE: SEE DRAWING 4 A8 FOR SHALL BE 3 5/8" MTL STUDS ANCHORED TO STRUCTURE ABOVE 3 5/8" METAL STUDS AT 16" SUPPORT OF LOW WALL ---. 1x OAK W ST-1 AT 16" O.C. FRONT TO BACK O.C. - ATTACH TO STRUCT. ABV. „�� + CgATIN)SE SEALER WITH CROSS BRACING IN OPPOSING DIRECTIONS 0 48 O.C. HORIZ FRMG AT MIDSPAN ACROSS „ a PLAS. LAM. (PL-2) HORIZ FRMG SHALL BE TOP OF SOFFIT FRMG. - 3 5/8" x 20 GA MTL FRMG. SECURED TO STR CT. ABV. 1x OAK TRIM 3 5/8" x 20 GA MTL STUDS W/ 8 GA. HANGER WIRE AT 48 O.C. ST-1 CLEAR SEALER (SATIN) 0 16" O.C. %u N, 2x8 OAK ST-1 r. SEALER 2x2 LAY -IN CELL'G (SATIN)AR TILES & GRID 00 TH SIDE] ALL CEILING AREAS SHALL RECIEVE 6 N, PLASTIC LAMINATE UNFACED INSULATION (PL-2) ON 1 /2" BATTS - R-19. I PLYWD. 10'-0" Cu 3 5/8" MTL A.F.F. FRAMING 2x4 VINYL 1/2" GYP. BD. 1/2" PLYWOOD FACED LAY -IN (PAINT PT-2) CEILING TILES + + ' 9-0" TILE BASE / AS SCHED. I, liz FOORING .� A SCHED. ELEVATION SECTION 5/8" GYP. BD. CEILING (PAINT PT-1) PIZZA PREP 111 FRP-1 ON 5/8" GYP. BD. 1" X 2 1/2" OAK TRIM - STAIN ST-1-----�_ CERAMIC TILE (CT-2) ON 5/8" W.R. GYP. BOARD - QUARRY TILE FLOOR AND BASE 8'-2" (REF. CLG. PLAN) NOTE! IN ALL CASES, WALL BOARD INCL GYP BD, 48" DIA. SIGN - PROVIDED BY W.R. "GREEN BOARD", DUR ROCK, ETC. SHALL BE TENANT; INSTALLED BY T.G.C. HELD UP 3/8" OFF FLOOR. AT ALL KITCHEN SIDE 1'-O" FROM UNDERSIDE OF CEILING DEMISING WALLS, THIS GAP SHALL BE FILLED WITH NP-1 EXTERIOR TILT WALL JOINT FILLER. ORDER METAL STUD AREA ENTRY FRAMING 112 101 5/8" GYP. BD. (PAINT PT-4) �-� 12"x12"x1/4" CERAMIC TILE REF. ELEV. 1 A14 (CT-5) W/ BLACK EPDXY VA NS IN WALL FINISHE� GROUT W/ 1/8" MAX. TILE IFOR AT ORDER AREA JOINTS UNDERSIDE OF ALL COUNTER 1x� fit" OAK TRIM WITH 1!2 CHAMFER OFFSET TOPS, EDGES, AND CUTOUTS 1 /8" BELOW TILE. SHALL BE PAINT (PT-5) FINISH WOOD W/ ST-1 2'-6 3/4" STAIN ND CLEAR SEALER SATIN BULLNOSE TILE O EDGE ---- 4 1 2" 0 STAINLES S EL SUPPORTtKNEEWALL �POM c� POST -1) 5/8" W.R. GYP BD A V. DUROCK. BB PANEL (L-) v MARLITE FRP (FRP-1) /8" MTL S U S 0 24" ' o FR GTO 5/8" DUROCK 12" A.F.F." PLYW00 CONT. CAULK M TILE FLOOR 5/8" DUROCK TO 12' .F.F. FLOOR &BASE NOTE! ALL WOOD BLK'G & PLYWWD OR PLYWD BACKING IN ANY WALL VOID OR CLG NOTE! PAINT UNDER SIDE OF AREA SHALL BE FIRE ALL COUNTERS & UNDER RETARDANT TREATED (F.R.T.). COUNTER BLOCKING PT-5 ('2-'WALL SECTION AT ORDER AREA A7.2 SCALES 3/4' = 1'-0' EASE ALL EDGES ON OAK CAPS ON BOOTH WALL AND ENTRY WALL. Lka--290T CERAMIC TILE (4"X12" BULLNOSE �r0 MATCH CT-4 PARTIAL HEIGHT, WALL 4 AT BOOTH PARTITIONS A 7.2]SCALD 3/4' = V-0' 7/A7.2 NOTE: SEE DRAWING 4 A8 FOR —� N SUPPORT OF LOW WAL --� / 1 x OAK CAP ST-1 1 CLEAR SEALER (SATIN) v+ PLAS. LAM. (PL-2 2x OAK TRIM ST-1 CLEAR J,--,,l(PL-2) SEALER (SATIN) CM LASTIC LAMINATE ON 1 /2"LYWOOD N FRACINGM� m I a I I 1 x4 OAK TRIM ST-1 CLEAR SEALER F(SATIN) ID ASESCHEb.4L 19MV 3 • 5 WALL AT ENTRY A �.2 SCALES 3/4' = V-0' EASE ALL EDGES ON OAK CAPS ON BOOTH WALL AND ENTRY WALL. 2x2 LAY -IN ACOUE CEILNG TILE & GRID 10 A.F. . 5/8' W.R. GYP BD NOTE! ALL WOOD BLK'G & 2x4 VINYL FACED LAY -IN PLYWD OR PLYWD BACKING CEILING TILES IN ANY WALL VOID OR CLG AREA SHALL BE FIRE RETARDANT TREATED (F.R.T.). NOTE! PAINT UNDER SIDE OF ALL COUNTERS & UNDER COUNTER BLOCKING PT-5 NOTE! IN ALL CASES, WALL BOARD METAL STUD FRAMING INCL GYP BD, W.R. "GREEN BOARD", DUR ROCK, ETC. SHALL BE HELD UP FROM FLOOR 3/8". AT ALL KITCHEN & RESTROOM WALLS, FRP-1 ON 5/8" THIS GAP SHALL BE FILLED WITH NP-1 GYP BD EXTERIOR TILT WALL JOINT FILLER. NOTES 12"x12"x1/4" CERAMIC TILE SET IN 1. G.C. SHALL PROVIDE BLACK EPDXY BED W/ 76" TILE JOINTS CUTOUTS FOR OWNER FURN. EQUIP. (VERIFY SIZES W/ EQUIP. SUPPLIER) 5/16" CEMENTITIOUS TILE BACKER BOARD GLUED & SCREWED TO (2) 2. DRAIN LINES FROM LA. 3/4" PLYWD. -'-' COKE, TEA & WATER - COORD. W/ EQUIP. 7/A3.2 SLEEVEORSYRUP & DRN DRAIN LINES FR BULLNOSE TILE I COKE & ICE MACH. SEE I / O 2x6 LEDGER x (ST-1) W/FLAT FINISH 2x FRAMING & 3/4" PLYWD. DIVIDER SEALER PANELS AS REQ'D TO �r LAM. PANEL (PL-2)7 TO SUPPORT EQUIP. o N 1 x4 WOOD TRIM SEALER W/FLAT FINISH " 1/2- PLYWOOD / QUARRY TILE / ASE QUARRY TILE CHAMFER BOTT �• r , %: .': • "' • . " • -' ::''' FLOOR ZD EDGE OF DOOR • ; _ ..�� ' V TILE FLOOR & BASE / SCHED. CONT. CAULK „ AT TOP OF BASE. 6 HIGH POURED CON( P (CONY. UNDER CABINET) SEE DET. 6/A7.3 3 REBAR CONT. 0 18" O.C. FOR BASE CONDITION A. WAY. " 8 1 SECTION THRU BEVERAGE STATION A7.2 % SCALEL 3/4' = 1'-00 8 U� N ao J" 08 >, C U Jt _ C o f6 > o n N � U ° ¢` O a o JM M J LL 0 ;n U °- . � cn ' o 0 r 0 0 0 z o' 0 m Q ' $ J � � J O Q � N o tiLJL 06 U O 0 0 O N Q J LO W W M J LL N Q=LL. O �.. OJ.. m J LU U Q =qt_ rY a U W 00 NCDN W Revisions: J_ Q 0 0 a z _O w U) Project Number 07059 Date 02-28-08 Sheet Number A7.2 NOTE! IN ALL CASES, WALL BOARD INCL GYP BD, W.R. "GREEN BOARD", DUR ROCK, ETC. SHALL BE HELD UP FROM FLOOR 3/8". AT ALL KITCHEN AREA WALLS, THIS GAP SHALL BE FILLED WITH NP-1 EXTERIOR TILT WALL JOINT FILLER. 9' - 4" A.F.F. LAY -IN ACOUSTIC CEIL'G TILE AND GRID REF. SHT. A16 FOR INFORMATION ON PAINT FINISHES. ALSO REF. A4, FINISH SCHEDULE FOR ADDITIONAL ROOM FINISH NOTES T.G.C. SHALL PHOTOGRAPH ALL WALLS & SHALL SEND TO CICI'S CORPORATE OFFICE PRIOR TO BASE INST'N. EXTEND & SEAL TO BOTTOM OF ROOF DECK 0 NON - BEARING FIRE -RATED SEPARATION 0 DEMISING WALL ale' WR= 70 AT INT. PART. WALLS - EXTEND STUDS 6" ABOVE FINISHED CEILING & FACE W/ 5/8" GYP. BD. TAPE & BED ALL JOINTS. 1 x4 OAK CHAIR RAIL 5/16" SHOULDER CUT (STA ST-1) W/CLEAR SATIN FINIS FIN. ,,, 2' — 4" Y A.F.F. PAINTED GYP. BD. FINISH / PT-4 BELOW WALL TRIM C BASE AS SCHED. FLOORING AS SCHED. ALL CEILING AREAS SHALL RECEIVE 6" UNFACED INSULATION BATTS - R-19 TYP. WALL FINISH rl'N AT DINING AREA A 7.3 SCALEi 3/4' = i'-0' 9' — 4" A.F.F. (-2x4 VINYL FACED LAY -IN CEILING TILES (ACT-2) /8" GYP. BD. EXTEND SEAL TO BOTTOM OF ROOF DECK 0 NON - BEARING FIRE -RATED SEPARATION 0 DEMISING WALL AT INT. PART. WALLS - EXTEND STUDS 6" ABOVE FINISHED CEILING & FACE W/ 5/8" W.R. GYP. BD. TAPE & BED ALL JOINTS. 5(8" PLYWOOD BACKING AT 4-0" A.F.F. LAID HORIZONTAL WHERE SHOWN ON PLANS (NO PLYWOOD ALLOWED IN DEMISING WALLS). /8" GYP. BD. MARLITE FRP PANELS (FRP-1) SEE DET. 6/A7.3 FOR BASE CONDITION 5/8" DUROCK TO 12" A.F.F. BASE AS SCHEDULED FLOORCOVERING AS SCHEDULED TYP, WALL FINISH 2 AT KITCHEN AREAS A % � 3 SCAM 3/4' = 1'-0' ALL CEILING AREAS EXTEND PLYWOOD SHALL RECEIVE 6" 4" MIN. ABOVE CEIL'G (TYP.) UNFACED INSULATION BATTS - R-1l.--.,\ / I II VINYL CEI G TI LCLAE &AGF ' MTL. STUD FRAMING OIL 10'-O" ANCHORED TO STRUCTURE ABOVE A.F.F. PROVIDE ESCUTCHEON PLATE 0 THREADED ROD PENETRATIONS 9'-4" 5/8' GYP. BD. THRU CEIL G TILES A.F.F. 3 5�p" MTL STUD FRM'G SEE PLAN F R DIMENSION x4 VINYL FACED LAY -IN CEILING TILES 0 1 O.C. ANCHORED TO STRUCTURE ABOVE FRP-1 ON 5/8" GYP. BD. //2" CDX P YWOOD T.G.C. TO INSTALL TENANT FURNISHED � AINT PT-5) CT MIC TILE (CT-2) ON t? WALL MURAL ON FURR DOWN. " 5 8 W.R. GYP. BD. (NOTE: T.G.C. TO USE HEAVY DUTY PRE MIXED VINYL PASTE.") 1/2" THREADED ROD SEE PLAN FOR ANCHORED TO ,,STRUCTURE DIMENSION ABOVE 0 4'-0 O.C. 1 1 /2"x18 GA. UNISTRUT TO FACE OF DEMISING WALL SERVING CONT. CONT. ALUM. CORNER 6'-11" + GUARD W/ 2" LEGS - — W-10" OIL _ A.F.F. SCREW TO SUBSTRATE 0 4-0 O.C. 0 HORIZ. A.F.F. 2._7>> & VERT. LEGS MATCH LINE - FACE OF CERAMIC TILE (CT-2) ON FURR-DOWNI TO FACE OF COUNTER 5/8" GYP. $&NT PT-1) 5/8 W.R. GYP. BD. FRAMING BELOW 12"xl2"xl/4" CERAMIC TILE I DISPLAY KITCHEN NOTE! ALL WOOD BLK'G & (CT-5) W/ BLACK EPDXY GROUT PLYWD. OR PLYWD BACKING W/ 1/8" MAX. TILE JOINTS 3'-4" IN ANY WALL VOID OR CLG 5/16" CEMENTITIOUS TILE FOOD GUARD AREA SHALL BE FIRE RETARDANT TREATED (F.R.T.). BACKER BOARD GLUED AND SCREWED TO 3/4" PLYWD. HEATED SHELF UNIT BY lx2 �Y4" OAK TRIM WITH 1/2" OTHERS -VERIFY SIZE WITHMFR. CHAMFER OFFSET 1 /8" BELOW & EQUIP. PLAN PIZZA PREP TILE. FINISH WOOD W/ ST-1 STAIN AND CLEAR SEALER V-2., 7/A3.2 (SATIN) ------------ NOTE! IN ALL CASES, WALL BOARD 7w BULLNOSE TILE INCL GYP BD, W.R. "GREEN BOARD", 1 x4 OAKTRI 5 8" W.R. GYP. BD. 0 EDGE DUR ROCK, ETC. SHALL BE HELD UP FROM FLOOR 3/8". _ 1 1 2" " " ST-1 ABOVE DUROCK x 1 12x 3 16 / / AT ALL KITCHEN AREA WALLS, 3J" ARLIT FRP ANGEL STEEL HANICALOLY THIS GAP SHALL BE FILLED WITH NP-1 �PM_2jANEL FRP-1) ATTACHED TO POSTS EXTERIOR TILT WALL JOINT FILLER. 0 //" 24q, GA MT - 1 /2" PLYWOOD STUDS 0 N KNEEWALL FRMG 1 x4 OAK TRIM 1 1 /2"0 STAINLESS STEEL -"� ST-1 5`,�"ADUF DUROCK TO SUPPORT POST - ANCHOR LL TO SLAB W/ EXP. BOLTS & ONT. CAULK PLATE - PROVIDE SEALANT AT ALL EDGES BASEFAS SC T.G.C. SHALL VERIFY ORIENTATION NOTE! PAINT UNDER SIDE OF OF ALL FIXTURES, MILLWORK, EQUIPMENT, ALL COUNTERS & UNDER ETC WITH PLAN SHEETS F1 & Al COUNTER BLOCKING PT-5 WALL SECTI❑N AT 3 DISPLAY KITCHEN A 7 3 SCALD 3/4' = 1'-0' EXTEND GYP BD 6" MIN. ABOVE CEIL'G (TYP.) VINYL CLAD LAY -IN CEIL'G TILE & GRID 9' — 4„ 4. F. F. 111'-FRP HORIZ FRM'G SHALL BE 3 5/8" x 20 GA MTL STUDS 0 16" O.C. go —of) A.F.F. PAINT PT-1 3 5/8" MTL STUD FRM'G 0 166" O.C. ANCHORED TO STRUCTURE ABOVE CT-2 CERAMIC TIE (3"X12" BULLNOSE TO MATCH CT-4) INST'D ON TOP OF RAISED (7¢") GROUT BED. z 2E CD �j K'5's CHAIR STOP DETAIL A 7 � 3 SCALES 3' = V-0' NP-I = SIKA A.F.F. POLYEURETHETHANE VERTICAL CONC. SEALANT CT-2 w ;o H FRP- INSTALL NP-1 CAULK TO SEAL JOINT AT DUROCK AND CONCRETE FLOOR T.G.C. SHALL FLOAT FLOOR SLAB UP AT DISP. KIT., KITCHEN & PIZZA PREP AREAS (ALL QUARRY TILE AREAS) RETURN CT-2 INTO NICHE AND BACK TO SIDE WALL BEYOND. i ` QT BASE & FLR� AS SCHED. WALL SECTI❑N AT WARMER NICHE A 7 � 3 % SCALES 3/4' = 1'-0' 7'-6" VERIFY PARTITION TYPE W/ FLOOR PLAN - G.C. TO INSURE THAT PRE-FAB ST. STL. SCREWS ARE 6" BASE TILE COOLER INTO STUDS OR PANELS APPROPRIATE BLOCKING '173" PANELS X 3" X 10" GALVALUME SURE ANGE - VIDED BY TENANT. ALLED BY T.G.C. SANITARY SEALANT - CONT. ALL JOINTS COOLER WALL 7 CLOSURE DETAIL �► 7, 3 SCALES 3/4' = 1'-0' MARLITE FRP PANELS - ,INSTALL TO 5" A.F.F. ,5/8" DUROCK TO 12- A.F.F. (TYP. 0 ALL TILE BASES EXCEPT IN GAME ROOM) -CLEAR SILICONE SEALANT CONT. ABOVE TILE BASE QUARRY TILE BASE -QUARRY TILE FLOOR T.G.C. SHALL INSTALL WATER-PRDC MEMBRANE (LATICRETE #9235 0 APPROVED EQUAL. TO 1 " A.F.F. & EXTEND 12" FROM WALL (TYP 0 AL LOCATIONS RECEIVING SLOPED F C 2'-0' MIN. SLOPE 6 TILE BASE DETAIL A 7 3 SCALEi 1 1/2' = V-0' INSIDE SURFACES OF CABINET SHALL RECEIVE MELAMINE - WHITE. UNDER SIDE OF COUNTER SHALL RECEIVE PAINT PT-5. NO EXPOSED WOOD ALLOWED. SYRUPFOR L DRAINI 12"x12"x1 /4" CERAMIC I I I I LINES. TILE BLACK EPDXYGROUT W/ 1/8" MAX. TILE JOINTS 7 I (I II II II II M DASHED LINES OF II II II 2x WOOD FRAMING DIVIDER WALLS BELOW NOTE! BULLNOSE TILE 0 EDGE HOLE FOR DRAIN & SYRUP SEE DTL. 5/A6. LINES SHALL BE SLEEVED W/ PVC & SHALL BE BEDDED, g BEVERAGE STATION PLAN CAULKED & PAINTED. SLEEVE SHALL EXTEND 3/8" OUTSIDE A 7, 3 SCALE, 3/4' = 1'-0' OF FINISH MATERIALS. HOLE TO BE B HIND COKE MACH 43) TGC TO VERIFY LOCATION PRIOR TO FABRICATION OF BACK PANEL. CERAMIC TILE (CT-5) ON — WALL. CERAMIC TILE (CT-5) ON COUNTER OP BULLNOSE TILE 0 EDGE 1 x4" OAK TRIM < SEAL GAP 0 CONC BASE TO CABINET. BASE AS SCHED. - 7'-6" "O HOLE F YRUP & DRAIN J 0 (PLASTIC LAM. (PL-2) 3I 1 /Fa EQUAL 3 I1 /e EQUAL/ 10 BEVERAGE STATI❑N ELEVATI❑N A 7.3 JSCALEi 3/4' = 1'-0' N io NOTESI 1. LOAD BEARING MATERIALS SHALL BE PROPERLY SIZED TO SUPPORT WEIGHT OF TELEVISI❑N,, EXIST. 2. UNISTRUT MEMBERS SHALL BE SECURED AT PANEL P❑INTS OF BAR BAR JOISTS J❑ISTS & WELDED (OR BOLTED) IN PLACE FOR STEEL STRUCTURES, SECURE TO STRUCTURE WITH AT LEAST \\V 3-FASTENERS PER CHANNEL OR SUSPEND BETWEEN BAR J❑ISTS AS REQUIRED BY JOB -SITE C❑NDITI❑NS VIBRATION IS❑LAT❑RS STEEL ROD II II I ALL THREAD 3/8' II II I II I II II II II I ALLOW SPACE FOR II II FRONT ACCESS II II I I I I I I TELEVISION II it I CEILING SUSPENDED N����\ N, TELEVISI❑N SHALL BE N'- N, SUPPORTED BY HANGER AND 1 5/8' UNISTRUT ROD IS❑LATI❑N WITH A SUPP❑RTING CHANNELS NE❑PRENE-IN-SHEAR STEEL AT TOP AND BOTTOM H❑USING. ( M❑UNTINGS SHALL BE STATIC DEFLECTI❑N. NOTES VERIFY WITH SELECTED TELEVISI❑N. MOUNTING DETAIL FOR CEILING SUSPENDED TELEVISION TELEVISI❑N 9 M❑UNTING DETAIL A 7 3 SCALES 3/4' = 1'-0' 2'-6" ACCESS PANEL TYP. BOTH ENDS HEAVY DUTY CON PIANO HINGE. �I PROVIDE w o LATCH IN < rn N I W m MITRE TRIM TO ALLOW FPIR DOOR SWING. TYP. 11 BEVERAGE STATI❑N END A 7.3 JSCALE, 3/4' = 1'-0' qz °, � ' =© J Io Nt c 0 Q r� _ E U- � y O N JCD °° x w CD U J 0 c c o cc O N N ` -/ 00 S r L U c Q 0 O t �a o Cl) M J LL 0 a � a V/ ■ miiii cn > o O o LO OD Z. � 0 c coo a c d d J O a7 = N U J C QLO Cl) ] O J LL U c c� 0 0 0 N O JLO co o N LU UJLL LL, o 3 0 CO V J =(D� WoMoW N co N Revisions: Z O F- W 0 Q J F- 0 Project Number 07059 Date 02-28-08 Sheet Number A7.3 I - I __ " I 1 1 l 1_ 1 1' 1 11111 llpmll!l 11PIP11111 1 11 1 II 1' 1 11 1 1 1 1 1 H'1 II _8J11'! I CER. TILE COUNTI CLEAT CONT. SUF ANGLE INTO END BASE AS SCHED. FOOD WELL CONTROL (PAINT (PT-5)) FOOD PROTECTION DEVICE 1 SERVING LINE ELEVATION A 7, 4 SCALEI 1/4' = Y-0' T.G.C. TO START TILE LAYOUT (CT-2) AT THIS POINT. WORK OUT IN ALL DIRECTIONS FROM HERE. TILE MAY ONLY BE CUT AT THE LAST COURSE AT CEILING & LAST COURSE ABOVE WALL BASE. —,- DISPLAY (OPEN) KITCHEN 1O2 NOTE! IN ALL CASES, BULL NOSE TILE SHALL BE USED ON ALL OUTSIDE CORNERS. CER. TILE(CT-2) ON SERVING SIDE OF WALL & AT JAMB CONDITIONS ONLY TILE COUNTER QUARRY TILE BASE MENU BOARDS, SUPPLIED BY TENANT, INSTALLED BY T.G.C. (PAINT (PT-4) ) ENTRY ORDER 101 COUNTER CER TILE COUNTER 2x2" OAK TRIM W// ST-1 STAIN & CLEAR SEALER (SATIN) 1 x4 OAK TRIM LAM. PANEL (PL-2) BASE AS SCHEDULED--/ BASE AS SCHEDULED 013 DISPLAY KITCHEN ELEVATION A7.4 SCALEI 1/4' = V-0' LOCATION) r-6"* ORDER COUNTER ELEVATION ��, SCALD 1/4' = V-0' PAINT PT-1 `PAINT PT-2 BOTTOM SIDE PAINT PT-4 PAINT PT-1 BOTTOM SIDE TILE BASE % SIGN FURN Y TEN INST BY TG IN 1E BASE AS SCHED LAMINATE PANEL (PL-2) " 7 l ORDER COUNTER ELEVATION A7.4 % SCALEI 1/4' = 1'-0' PAINT PT-2 ff Na EXPOSED E[ CONDITIONS SEE 2 Al2 WALL FINISF OAK TRIM - STAIN ST-1 PAINT PT-4 T.G.C. TO INSTALL TENANT FURNISHED WALL MURAL ON FURR DOWN. (NOTE: T.G.C. TO USE "HEAVY DUTY PRE MIXED VINYL PASTE.") CUT TO 6"( xT6) BASE AS SCHED LAMINATE PANEL (PL-2) NOTE! "WALL MURAL" IS A CUSTOM VINYL WALL COVERING. IT IS NOT A "PEEL & SUCK" GRAPHIC. IT IS TO RUN THE FULL LENGTH OF FURR DN. TRIMING SHALL ONLY LY TAKE PLACE AT THE ENDS & TOP & BOT ONLY AS REVD. PAINT PT-2 I PAINT PT-1 BOTTOM SIDE PAINT PT-4 �AT WALL BEYOND x 2 SERVING LINE ELEVATION A 7, 4 SCALEI 1/4' = 1'-0' OTEACER. ENDOUETN WALL IN LINE WITH SOFFIT ABOVE BASE AS SCHED. 4 KITCHEN ENTRY ELEVATION A7.4 SCALEI 1/4' = V-0' PAINT (PT-4) CT-2 & BULL 48" DIA. SIGN OAK TRIM - STAIN ST-1— ENTRY SIDECOF21ALL ORDER AT JAMB CONDITIONS ONLY INSTALL (1) TILE COURSE PAST WALL OPNG. AND WRAP ONTO JAMBS OPENING FOR CARRY OUT WARMER 0 Cu za S ORDER ENTRY ELEVATION A7,4 JSCALD 1/4' = 1'-0' o O O J r- C Q U- E CO n rn CV C 0 O x O 75 JLL o > N � N O � N U O O Q L o. 0 JM J LL 001) 3 aD Ua . � in > 0 O LO Cz o > o O O) N J z U C LO Q J O n LL J U C O 0 N O J _I M � � wWoNQ = O CLm� LU () Q a U CL�_ W00LU N(0N Revisions: Project Number 07059 Date 02-28-08 Sheet Number A7.4 TO MAIN SAN. SEWER, l L EXIST 4' SAN, SEWER EXIST 4' SAN, SEWER EXIST 4' SAN, SEWER ----it--------------- ------------------------------------------ — — — — — -------------------------------- STUB FOR FUTURE TENANTS \ GAS 1 FROM METER .I. GAS C❑. CONNECT TO EXIST 2 1 � 4' STUB, PLUMB 3 3 3 3 _ 20 2 P=4 CONTRACTOR TO 52 VERIFY L❑CATI❑N MEN i COOLER 2' 110Li Li LU C55 104 I I P=4 L____' F WNMEN 109 EXIST 4' GREASE LINE GAME ROOM 108 _ 3' FLOOR 4' Cu Cu DRAIN N, 0 730 3/4' 1/2' Cw_ 1/2' CW _ 1/2' CW CW^ 0 1/2' HW , 1/2' HW 1 ' 3' 21 I EXIST 4' STUB I 3' JDRAI WH 3' DRAFLOIN 35 ' 83 5335 I ' • • r 3• 1' 3J DRAIN 3# (\ � DRAIN 1/2' CW FLOOR 24 CNRR, P-10 _ + 6 3G 3' DRAIN 46 PIZZA 111 I cu PREP, PREP 31 (UI ' 1 KITCHEN 7 3' HUB 41 F] 103 I 105 DR IN ICl .14 25 19 3 5 42 U �) DRAIN i 44 43 (i \ N 5 81 — — — — — 7-------�---------------L�— \ --�-- BEV. "' —� — -- T— { 30 ----- ---- -- - STATION • r r 1G6 I r 1• ' TO EXIST, 1500 EXIST 4' GREASE EXIST 4' GREASE CONNECT TO EXIST 4' GAL. GREASE TRAP LINE STUB LINE STUB GREASE LINE STUB. UNDER PAVEMENT PLUMB CONTRACTOR T❑DISPLAY VERIFY L❑CATION 27 KITCHEN F I 102 � - 1: - S ING �I 8 , I I DINING 107 1 3 1/2' HW I 33 I r_2 �O _ 3' P� 1/2' CW 17 4 3• I 3' 2 3 3' I FL DRAIN O 3' 0 FLOOR 1 4 S 28 DRAIN I� O0 I U 16 ORDER • � I 101 I —j — — co 72 71 71 TO EXIST. 3/4 I METER W/ BFPD, THEN TO CITY WATER I ENTRY 100 I I 1 PLUMBING FLOOR PLAN P -1 SCALES 1/4' = 1'-0' a D FURNITURE AND EQUIPMENT SCHEDULE #1 NO. DESCRIPTION MANUFACTURER MODEL NO. SIZE WxDxH FURN. INSTALL VOLT IPH HP JAMP lCONN. DRAIN CW* HW* GAS BTU REMARKS NO. DESCRIPTION MANUFACTURER MODEL NO. SIZE WXDXH FURN. INSTALL VOLT PH HP AMP CONN. DRAIN CW* HW* GAS BTU REMARKS I WIRE SHELVING ISS SHELVING VARIES TENANT G.C. 44 ICE TEA MAKER BUNN T6 17X17X29 TENANT G.0 120 1 14.87 1 PLUG 1/4' 2 DUNNAGE RACK ALUM SPECIALIST VARIES TENANT G.C. 3 PORTABLE RACK NEW AGE INDUST, 6301 20 1/2X27 1/2X69 TENANT G.C. 46 CARBONATOR GENERIC COKE COKE 120 1/2' 4 WIRE SHELF (CUT TABLE) ISS SHELVING (2) 18 X 48 TENANT G.C. 51 CONVEYER OVEN LINCOLN 1600 75 1/4X 58 3/4 TENANT G.C. 120 1 14 PLUG/ EACH DECK 3/4 110000 EA 5 PIZZA PAN WALL RACKS --- --- --- TENANT G.C. 52 DOUGH MIXER HOBART P-660 27 1/2'X39 1/4' TENANT G.C. 208 3 2.5 8.6 DIRECT 6 UNDERCTR. SUSP, WIRE SHELF ISS SHELVING --- 24X48 TENANT G.C. 53 PASTA COOKER FRYMASTER BBC 18X32 3/4X49 TENANT G.C. 208 1 39 PLUG 3/8' 3/8 7 SYRUP RACK ISS SHELVING --- IBX48 TENANT G.C. 54 DOUGH PRESS PROPROCESS CORP. DP-1100 17XI8X25 TENANT G.C. 120 1 12.5 PLUG 14 30' HEATED SHELF HATCO GRSB-30-F 1700 1/2 TENANT G.C. 120 1 4.2 PLUG 55 COOLER KOLPAK CICI 7'-9'X14'-5 1/2'XB'-4' TENANT G.C. 230 1 1 DIRECT 15 18' HEATED SHELF HATCO GRSB-I8-F 17xl9 1/2 TENANT G.C. 120 1 2.8 PLUG CONDENSING UNIT KOLPAK PCL 145M TENANT G.C. 208 3 1 1/2 10.7 DIRECT 16 LIGHTED FOOD GUARD HATCO --- 18400 2 SALAD BAR TENANT G.C. 120 1 4.0 DIRECT EVAPORATOR COIL KOLPAK HM-145 TENANT G.C. 120 1 4.2 DIRECT 1' COPPER DRAIN 17 LIGHTED FOOD GUARD HATCO --- 18x54 8 PASTA BAR TENANT G.C. 120 1 2.5 DIRECT 61 WATER HEATER STATE SBN75-120 NE 2SX75 G.C. G.C. 120 1 DIRECT POP OFF TO 1' 1' 3/4 120000 18 LIGHTED FOOD GUARD HATCO --- 18428 2 WARMERS TENANT G.C. 208 1 13.6 DIRECT PROVIDE SEPARATE NEUTRAL FOR LIGHTS 62 CO2 TANK VENDOR G.C. 19 LIGHTED FOOD GUARD HATCO --- 18405 @ WARMERS TENANT G.C. 208 1 12.4 DIRECT PROVIDE SEPARATE NEUTRAL FOR LIGHTS 71 P.O.S. REGISTER TENANT G.C. 120 1 2.0 PLUG 20 HOT FOOD WELLS APW/WYOTT HFW-4 WELL 58-1/2x23-7/16x56-7/8 TENANT G.C. 208 6 23.1 E.C. TO FURN & INST CORD CAPS. COPPER DRAINS W/SHUTOFFS 72 SAFE ROLLAND 82015 20'Hx15'Wx15'D TENANT G.C. 21 8' WORK TABLE (PREP) TABCO AG SERIES 30X96 TENANT G.C. 73 81 TIME CLOCK AMAND 3500 SERIES 8 1/4X10 1/2X6 TENANT G.C. 120 1 0.3 PLUG 22 6' WORK TABLE (STRETCH) TABCO SG SERIES 3OX72 TENANT G.C. TYPE II OVEN HOOD MASTER AIR INC, CICI-A 9'-O'X6'-O'X2'-6' TENANT G.C. 120 1 2 DIRECT 23 7' WORK TABLE (CUT) TABCO AG SERIES 30X84 TENANT G.C. EXHAUST FAN SEE MECH. DWGS. --- --- --- 24 PIZZA MAKE TABLE DELFIELD 186114PTB 31.5 X 114 TENANT G.C. 120 1 14.0 PLUG SUPPLY FAN SEE MECH. DWGS. --- --- --- --- --- - --- - 25 4' HEATED SHELF HATCO GRSB-48-F 19X49 1/2 TENANT G.C. 120 16.4 rI/2 PLUG 82 SPLASH GUARDS ADVANCE TABCO VARIES (COORD. WITH ADJACENT SINK DIMS.) TENANT G.C. --- -- --- --- --- 27 28 6' HEATED SHELF SALAD DISPLAY UNIT (ROLL -IN) HATCO McCALL GRSB-72-F 17x73 1/2 93 1/8x34x34 TENANT TENANT G.C. G.C. 120 120 19.4 1 16.0 PLUG PLUG 83 84 PAPER TOWEL DISPENSER TAKE OUT PIZZA WARMER FWE TS-1633-36 25.25x37.25x69 TENANT TENANT G.C. G.C. 120 1 2 11.3 PLUG SEE SHEET A3 30 31 4' UNDERCOUNTER WARMER DISHWASHER & TABLE HATCO ECOLAB GRSB-48 T.B.D. 19 1/2x48 TENANT TENANT G.C. G.C. 120 1 1 3/4 1 8.3 PLUG PLUG 2' INDIRECT 3/4 EXTE D LEGS TO FULL HT. 91 92 93 IGAME COIN CHANGER WALL HUNG TRINKET MACHINE TENANT TENANT TENANT G.C. G.C. G.C. 32 3-COMPARTMENT SINK w/ PRE -RINSE CBOWL SIZE = 20'x20'x14'N DRAIN BOARD SIZE (INTEGRAL) = 36'x27') ADVANCE TABCO 9-23-60-24RL 115X27 TENANT G.C. 2' INDIRECT 1/2' 1/2' 95 TELEVISION GENERIC 36' TENANT G.C. 120 1 3.0 PLUG INCL SUSP'N BRKT 97 DINING TABLE (4 TOP) TENANT G.C. 33 HAND SINK ADVANCE 7-PS-50 17 3/4 TENANT G.C. 1 1/2' DIRECT 1/2' 1/2' 98 DINING TABLE (2 TOP) TENANT G.C. 34 MOP SINK FIAT MSB 2424 24X24 G.C. G.C. 3' DIRECT 1/2' 1/2' 101 BOOTH TABLE (4 TOP) TENANT G.C. 35 PREP SINK ADVANCE TABCO T9-21-20 140X24 TENANT G.C. 2' INDIRECT 1/2' 1/2' 103 BOOTH SEATING (SINGLE) TENANT G.C. 41 ICE MACHINE w/ REMOTE CONDENSING UNIT SCOTSMAN CME 506 /HTB 550 42X31.5 TENANT G.C. 120 1 19 PLUG 1/2'INDIRECT 3/8' 104 BOOTH SEATING (DOUBLE) TENANT G.C. 105 WALL GRAPHICS TENANT G.C. 42 43 ICE MACHINE - SELF CONTAINED DRINK DISPENSER SCOTSMAN ICOKE _ CME 656 DURAFLEX 250 30X3OX39 TENANT COKE G.C. COKE 208 120 1 19 PLUG 1/2-INDIRECT 3/8' 106 MENU BOARDS TENANT G.C. c M O � 0 0 N oQ r d 8 E U� o CV N C co °, CM U ' JlL CD T 0 a ° N N C L Q oN a = d 0 JCY) J LL 0 e L) M 0 0 co ° z co o L I Q c ° N J / p� IC)t y J '6Q U J ° J LJL as U 0 O 3 N, 0 0 N Cl 04 'JQM w�LL O U- ill N UQ =ram o a _J Co Wow N CD N Revisions; f R Z in ;:. k=. N :2 J O O � Q �n a ^ LL J o LL 1i Project Number 07059 Date 02-28-08 Sheet Number P-1 r ALL WATER CONNECTIONS FROM STOP VALVE TO EWW ENT SHALL BE WOVEN STEEL MESH FLEXIBLE LINES. STUB FOR FUTURE TENANTS FROM PEOPLES AUTOMATIC GAS GAS SHUT-OFF FROM HOOD SYSTEM ❑UTSIDE BUILDING GAS METER VALVE HARD H❑ OR FLEX =2LB WITH 330, 66' DEV NFPI 2 Ll DRIP LEG 3 GAS RISER DIAGRAM P - 2 SCALEi N.T.S. P-1 I \ \ P- � \ P-4I" i I',- - \ Ile TO MAIN SAN. r 2' / �-� \ SEWER, J IN 21 `\ • i{VTR \ \ I \` 2' \ 3' q, P 1 3• \ \ P4 2' q• P-3 2' \ \ \ P 1 4' P 2 \\ 4' 4' 4' `\ g• S PLUMBING FIXTURE & CONNECTION SCHEDULE MARK DESCRIPTION W CW HW MTG, HEIGHT MANUF. FIXTURE # TRIM # WASTE NOTES � WATER CLOSET FLUSH TANK 4' 3/8' - FLOOR TO KOHLER 'WELLW❑RTH' 'LUSTRA' 4' WHITE SEAT & COVER SUPPLY AND WASTE HANDICAPPED RIM 16-1/2' K-3481 COVER SEAT W/ COVER STOP BOLT COVERS P- WATER CLOSET 4' 3/8' _ FLOOR TO KOHLER 'WELLWORTH' 'LUSTRA' K-4652 4' WHITE SEAT & COVER SUPPLY AND WASTE FLUSH TANK RIM 14-1/2' K-3432-UT SEAT W/ COVER STOP BOLT COVERS P 3 URINAL 2' 3/4' - FLOOR TO KOHLER 'BARD❑N' _ 2' _ RIM 17' K-4960-ET LAVATORY FLOOR TO 'GREENWICH' WRIST BLADES 1-1/2' WALL HANGER P-4 WALL HUNG 1-1/2' 1/2' 1/2' RIM 34' KOHLER K-2032 HANDLES FAUCET •P' TRAP OFFSET DRAIN HANDICAPPED 3/8' SUP, STOP INSULATE FOR H.C. P 5 LAVATORY 1-1/2' 1/2' 1/2' FLOOR TO KOHLER 'R❑NDELLE' WRIST BLADES HANDLES FAUCET 1-1/2' SUPPLIES WITH COUNTER MOUNTED RIM 34' K-2185 3/8' SUP. STOP •P• TRAP STOPS P-6 ELECTRIC WATER 1-1/2' 1/2' - FLOOR TO BUBLER SUNROC NWCA-8-BL - 1-1/2' SUPPLIES W/ STOPS COOLER 35-3/4' 'P' TRAP HANDICAP-CO❑LER --7 HAND SINK (NO, 33) 2 1/2 1/2 FLOOR MOUNTED ADVANCE 7-PS-50 AS SELECTED 2' P-TRAP - P-8 I MOP SINK (NO, 34) 2 1/2 1/2 FLOOR MOUNTED FIAT MSB 2424 AS SELECTED 2' P-TRAP - PREP SINK (NO, 35) 2 1/2 1/2 FLOOR ADVANCEMOUNTED TABCO T9-21-20 AS SELECTED 2' P-TRAP - P-10 DISHWASHER (NO, 31) 2 1/2 1/2 FLOOR MOUNTED ECOLAB AS SELECTED AS SELECTED 2' P-TRAP - P= 3-COMPARTMENT SINK 2 1/2 1/2 FLOOR ADVANCE 9-23-60-24RL AS SELECTED 2' P-TRAP - (NO. 32) 1 1 1 MOUNTED TABCO (� _iCONNECT TO EXIST PqN, 4' STUB, PLUMB CONTRACTOR TO `\ VERIFY LOCATI❑N \ / \ �2' \\ 2' 3' HUB 2' \ \ 2' I \ DRAIN ( \ / \ \ 3' \ \ / / 2'31 \\\ \\ /// VTR \ 2' \\ loll 2' \ 2' / CONNECT TO EXIST 4' \ r GREASE LINE STUB, ( / \ 2 PLUMB CONTRACTOR TO \ HF �� , C \ \ VERIFY LOCATION \ \ \ (ig RF \� 3• �FLOOR \ 3' \\ 3' DRAIN 11 DRAIN EXIST 4' STUB. ' \ \ \ \ \ 3' HUB 2' /� \ `\ 3 \ 3' g' \ F 3' FLOOR I P-9 P 5 . P-6 \ /� <IN� \ \ 3, DRAIN i /> I- ` 4• Sq \ 3 \ F { FLOOR i� 1j/ /��--�\\\ ��� DRAIN 3• I2, 2• /"1 \ 2 \ 3, 3' HUB { // S \ CONNECT TO EXIST 4 3, DRAIN � 3 / �\ T g• \ \ GREASE LINE STUB, 3' 3' (; \ PLUMB CONTRACTOR TO / / , RFgS VERIFY LOCATION / 2 \ F / 3' 3/ / P-10 I . 3� \ / 3 P-11 3' 1i�• FLOOR / DRAIN / THERMAL AN \ y�✓ / / / \ EXPA2' �► G� / PROT / 13/4'c3'11GRASSC AREA VAEAT, 3•DRAIN PROVEDOPS LVE( P-9 3' \`\ � IWH 1 3 ��\ G� C 20 GAL. R 1 V 31 � WATER HEAT E TO EXIST, 1500 I GAL, GREASE TRAP { \ ON FLOOR 3' a� P 7 UNDER PAVEMENT / \ - \ —77 FLC-- DRF \ TO EXIST. 3/4 METER W/ BFPD, THEN TO CITY WATER . C%w \ \ 1 WATER RISER DIAGRAM IP-2 SCALEe N.T.S. J r L_uum DRAIN 2 P-2 SANITARY RISER DIAGRAM SCALE, N.T.S. ` c E 41 N 00 J" ,s o M U. a o CV N °D WN U .4) ¢` 0 t ` a T 0 JM M J LL 0 Lo 2 Ua 0 o 00 z C o c m Q d d J 01 C O J 0 Q � N J 0 Lf)� J oa U 0 0 0 N J 'J Q � M 0O W J J U_ N Q = LL O a. -J m J LU W Nco W N Revisions: cD g z(D m J � CL W O Project Number 07059 Date 02-28-08 Sheet Number P-2 x (LJ 150�� 22X10 E-l' 150[��� 22X10 100 22X22 \ M—� / -- - - - - E-1 y �� 400 (TYP.) II 6 22X22 120 140 SD 140 — .e. 3 350 S-1 a 5 o0 S-1 100 350 ICE MACHINE N 200 x 001 1 00 12 80 S-1 � 75 (TYP.) 60 60 KITCHEN 12 600- 22X22 p - 9 -_ 100 — - -- — - Q(TY SERVING GAME R❑❑M S-1100S-1 R-1 2751100 100 27510�100 22X22 xP. 100 s 1 275 275 100 x 100 100 CD S-1 S-1 100 275 275 100 100 100 s-1 275 100 S-1 275 1 00 x 100 R-1 275 0 1 ,100 - --- 22X22 10 100 100100 100 1 140 RTU-2 1 00 L DINING v -1 4- S 140 M-2 x 275 - s-1 .2 10� I� • '6300 (TYP.) S-1 M-2 275 I 140 100 ?71� 1 nos . I S-1 - 27-5 1 100 00 S--1 100 S-1 300 100 MECHANICAL FLOOR PLAN N❑RTH SCALE: 1/4"=1'-0" HVAC CONSTRUCTION NOTES: O1 52X26 SUPPLY AIR DUCT DOWN FROM RTU-1 . O2 59X18 RETURN AIR DUCT UP TO RTU-1. S-1 O3 34X18 SUPPLY AIR DUCT DOWN FROM RTU-2. 350 100 100 O 34X18 RETURN AIR DUCT UP TO RTU-2, O5 34X18 SUPPLY AIR DUCT DOWN FROM RTU-3. 3 O 34X18 RETURN AIR DUCT UP TO RTU-3. 'RTU-3 M-2 v PIZZA PREP (TYP.) O 20X16 16 GAUGE GALVANIZED STEEL EXHAUST AIR DUCT CONTINUOUSLY WELDED LIQUID TIGHT, DUCT CONNECTION UP TO EF-1 . 9 9 9 9' O8 12X10 SUPPLY AIR DUCT DOWN FROM SF-1 S-1 200 80 O9 14X14 EXHAUST AIR DUCT UP TO EF-2. 8 7 10 24X15 16 GAUGE GALVANIZED STEEL EXHAUST AIR DUCT CONTINUOUSLY 20X12 I WELDED LIQUID TIGHT, ROUTED TO EF-1 DUCT CONNECTION. I 11 REFRIGERANT PIPE ROUTED FROM PENETRATION THROUGH ROOF. 10 12 CONDENSATE DRAIN ROUTED TO CLOSEST FLOOR DRAIN. ENTRY S-1 300 100 H-1 MECHANICAL PERMIT DOCUMENTS®2007 AIRCO MECHANICAL, INCORPORATED DESIGN. Certificate of Authorization No.: 27407 CONPTS ARE THE_ BUILD. THESE MECHANICAL DOCUMENTS, DESIGNS, NOTES, — RCO SOLEDETAILPRO ERTTYICAONS OF¶ARCO MDECHANIICCAL, INC, AND M E C H A N I C A L� SOLUTION._ SHALL NOT BE REPRODUCED, RE —USED OR COPIED FOR OTHER PROJECTS, WRITTEN CONSENTIOF JASONOLEOM HEFFELMREPATOUT PE CM C. 6334 118TH AVENUE N. P: 727-547-9700 ALL ARE RESERVED BY THE ENNEER RECORD NSACCORDANCE WITH U.S. COP�YRIGHTOAND LARGO, FLORIDA 33773 F: 727-547-9754 PATENT AND USE WILL BESD PROSECUT RIZED TO THE FULLUCTION EXTENT OF VVM.AIRCO-MECHANICAL.COM THE LAW. N N N \� \ 00 O CD \. CU 0 W t� N N J Jn 0 we LL a o ., g - (% _ 04 a cli co z N Q OC 0 \ L o_ 0 m a U_ a O N � L O O 0 z (0 >_ � U O Q on U O LO _J T J LJL ad 0 Ca 0 0 O 04 O It CM co OILL z o N N om Q C) 0 _J o o a- U_ U J M (� J LL U) J W N Revisions: J z U__J z � Q � 2p W 0 J V- Project Number 163 Date 11-16-07 Sheet Number M-1 I 1 11111 1 1 1 1 1 1 I 1 1 1 1 1 1 1' 1 1 1 11111101 1 5' Q U M 8' 1 � � 7 I IIT Ill 1 �1 3`10 ll I IV�>< II I II L3'-4" I 11 11 10'-5 RTU-2 1060 LBS. 1' - 5 2' I IL 1'-52" 10' 6 D2C1 M-2 5' ICE 7' MACHINE COOLER ClN, CON. 8„ 600 LBS, 8„ PIPE 16' PENETRATI❑N I GOOSENECK EF-2 55 LBS. 21' Q U Q 4 (TYP.) 8, 8 M-2 (TYP.) I� KT II I Ilia X �I 3 -10 IIL3'-4- L (TYP.) RTU-3 1060 LBS. 5D (TYP.) 5 M-2 (TYP 1 41'-4" MECHANICAL R❑❑E PLAN SCALE: 1/4"=1'-0" ME HVAC CONSTRUCTION NOTES: O1 REFRIGERATION RACK PROVIDED BY MECHANICAL CONTRACTOR. O2 CONDENSING UNITS PROVIDED BY KITCHEN EQUIPMENT MANUFACTURER AND INSTALLED BY MECHANICAL CONTRACTOR. O3 PENETRATION STEEL FRAME BY STRUCTUAL CONTRACTOR. 4O CONDENSATE DRAIN ROUTED TO ROOF GUTTER. MECHANICAL PERMIT DOCUMENTS©2007 A1RCO MECHANICAL, INCORPORATED DESIGN. Certificate of Authorization No.: 27407 THESE MECHANICAL DOCUMENTS, DESIGNS, NOTES, 0 _ BUILD. DETAILS, SPECIFICATIONS AND CONCEPTS ARE THE RC SOLUTION._ SOLE PROPERTY OF AIRCO MECHANICAL, INC. AND M E C H A N 1 C A L„ SHALL NOT BE REPRODUCED, RE —USED OR COPIED FOR OTHER CSENIYON°HERME WRRINONNTOFJA �FEREE CMC. 6334 118TH AVENUE N. P: 727-547-9700 ALL ARE RESERVED RECORD INS ACCORDANCE NHYU.SECOPYRIGHT THENGINEEROAND LARGO, FLORIDA 33773 F: 727-547-9754 PATENT LAWS. UNAUTHORIZED REPRODUCTION AND V"".AIRCO-MECHANICAL.COM USE WILL BE PROSECUTED TO THE FULL EXTENT OF THE LAW. N O) N �00 oCD cc LU a o y J 0 J U 0 M CIL > o-F, o cn ^ _ 04 C L oDQ r_ 0 o a J 0LL U° CL 0 oN CO C� .0 0 O0 o z a� 0 c Q N J 0� i0 C J O J pj J LL U O cc O 0 N Q N mot' LO M C" M O � z o �W co a. 0 UJ U Q _J w N o0 _� co J O J W N Revisions: Q Z UJ QLL =O w0 5� Project Number 163 Date 11-16-07 [:M-2 heet Number FAN TO BE SECURI TO CURB WITH PRE ENGINEERED HINGE' 18 GAUGE GALVAN STEEL CONTINUO( WELDED LIQUID 7 ROOF CORNERS ARE CLIPPED SUPPORT FD r-l"" STRUC_ PIPE HANG PIPE SADDLE I FLARED EDGES NOTCHED TO F PIPE HANGER. FLARED FLARED PIPE SADDLE END EDGES (TYP.) LENGTH=2X ALL INSULATION PASSES INSULATION O.D. THRU HANGER UNBROKEN NOTE: HANG ALL PIPE PER 2004 ASME BUILDING SERVICES PIPING STANDARDS. 9 PIPE HANGING DETAIL M-3 NOT TO SCALE BASE SECURED 1 2—#10 ETMETAL SCREWS THREE SIDES Z� SSE CONTAINE NFPA #96 ., ,L, , , ,, .,`ED STEEL CURB BASE CAP CONTINUOUSLY WELDED LIQUID TIGHT EXHAUST DUCT TO SUPPORT FAN IN CASE OF FIRE REFER TO ROOF CURE EQUIPMENT TIE DOWN DETAIL 7 THIS SHEET (TYP.; SHEETMETAL SCREWS ON FOUR SIDES 10 HOOD EXHAUST FAN AND SUPPLY FAN DETAIL M-3 NOT TO SCALE 1 /2"0 RODS WITH THREADED JOIST END FOR HOOD SUPPORTED FROM STRUCTURE. LOCATE ROD AT APPROX. 18 FROM END OF HOOD AND AT NO MORE THAN 6'-0" O.C. WITH ADDITIONAL SUPPORT SECURE HOOD TO POINTS AS REQUIRED. BACK OF WALL 6'-6" A.F.F. UNLESS NOTED OTHERWISE — H—# EXHAUST DUCT CONNECTION WALL 1 f7, /0 1 IN110TE71 IT FOR LENGTH & WIDTH REFER TO FLOOR PLANS 11 HOOD HANGING DETAIL M-3 NOT TO SCALE J V I I L I V V V I CONNECTION SEAL LOUVER OPENING TO PERIMETER USING BACKER ROD AND SEALANT OUTSIDE AIR LOUVER W/ BIRDSCREEN Z i0 1 .0" MIN. UNC ASTM 3OLT, MIN. 12" MAX. S, 1 —1 /2" MAX. FROM �S AT HEAD AND SILL /4" THICK ')TEEL MIN. ELIDED STEEL FRUCTURAL JPPORT FRAME 1 /4" THICK STEEL MIN. ANCHOR PLATE 1 " ANCHOR PLATE NOTE: INSTALL ANCHOR PLATES AT OPENING HEAD AND SILL USING SPECIFIED ANCHORS ON MAXIMUM 12" CENTER, 1.5" MAXIMUM FROM OPENING CORNERS. ANCHOR PLATES SHALL BE PRE —PUNCHED FOR HOLE LOCATIONS. FRONT EDGE OF PLATE SET BACK 1 " FROM FRONT EDGE OF LOUVER. (�7 LOUVER INSTALLATION DETAIL ROOF MOUNTED EQUIPMENT EQUIPMENT CURB WELD TO CURB AND STRUCTUAL STEEL NOT TO SCALE CHANNEL STRAP & SADDLE PP <M�N i SCR MAIN DUCT SUPPLY/RETURN/EXHAUST LOCKING SEAL WITH TAPE __ __ _ QUADRANT TO AT SEAM BE EXPOSED FLEXIBLE DUCT: CONNECT VOLUME DAMPER INNER DUCT WITH NYLON IN COLLAR DRAWBAND AND SEAL NECK I CONNECTION WITH TAPE I I <M�Ni RIGID PIPE: CONNECT WITH W S-1, SCREWS AND SEAL NECK CONNECTION WITH TAPE I I BRANCH DUCT I INSULATION —� ROUND TAB COLLAR 1 BRANCH DUCT TAKE —OFF DETAIL PP �M�N i „ SCR 5/16" SCREWS (TYP.) STRAP & BEND NOTE: HANG ALL DUCT PER 2005 SMACNA HVAC DUCT CONSTRUCTION STANDARDS METAL AND FLEXIBLE. #14 HEX SCREW THROUGH EQUPMENT 4 DUCT HANGING DETAIL RAIL AND CURB EVERY NOT TO SCALE 12" OF PERIMETER M-3 BUILT UP ROOF 8"X3" FLAT STEEL' ROOF DECK 3/16" FOUR PER SIDE STRUCTURAL STEEL BY OTHERS TYPICAL ROOF CURB EQUIPMENT TIE DOWN DETAIL NOT TO SCALE MOUNTING BRACKET SECURED TO EQUIPMENT BASE BOLTS AND WASHERS 1 /4" - DIAMETER SAE GRADE 5 ASTM—A449 FIELD SUPPLIED VENTED CAP—\ CLEAN OUT PVC PIPE ROUTE TO NEAREST OUTLET DESIGNER'S NOTE: RTU—# A DRAIN LINE SHALL BE AT LEAST THE SAME B SIZE AS THE NIPPLE ON THE UNIT DRAIN AHU TYPE A B DRAW THRU 2" + X X + 1" BLOW THRU 2" MIN. 2X WHERE X = STATIC PRESSURE IN DRAIN PAN 5 UNIT DRAIN TRAP DETAIL �M-3 NOT TO SCALE SECURE T( STRUCTUAL STEE EQUIPMENT STAND DETAIL NOT T❑ SCALE :K NOT TO SCALE S S , lRgp 0 M 11-ov l MAXIMUM SAG OF — 1 /2" PER FOOT OF SUPPORT SPACING NOTE: HANG ALL DUCT PER 2005 Co TO SMACNA HVAC DUCT CONSTRUCTION NtiFc�O STANDARDS METAL AND FLEXIBLE �IC N FLEXIBLE DUCT HANGING DETAIL NOT TO SCALE MIN 6" EXTENSION I I I CONNECT INNER DUCT ATTACHED TO DIFFUSER OR I WITH PANDUIT DRAWBAND SQUARE TO ROUND I I AND SEAL WITH I TAPE/MASTIC OUTERDUCT SQUARE TO I I AT NECK CONNECTION ROUND ADAPTER I I PROVIDE THERMAL (WHEN APPLICABLE) I I INSULATION BLANKET IF — INSTALLED IN UNCONDITIONED SPACE \--LOUVERED FACE CEILING DIFFUSER SUSPENDED LAY IN CEILING SYSTEM DIFFUSER CONNECTION DETAIL NOT TO SCALE MECHANICAL PERMIT DOCUMENTS02007 AIRCO MECHANICAL, INCORPORATED DESIGN. Certificate of Authorization No.: 27407 _ BUILD. THESE MECHANICAL DOCUMENTS, DESIGNS, NOTES, DETAILS, P SPECIFICATIONS OFAIRCO I nMECHANICAL, PTS ARE THE INRCO SOLEPROPERTY AL, INC. AND M E C H A N I C A L- SOLUTION._ SHALL NOT BE REPRODUCED, RE —USED OR COPIED FOR °wm"ITEN PROJECTS, OF"a ON M.M. OR HEFFE MITRE PETHCMC. 6334 118TH AVENUE N. P: 727-547-9700 ALL RIGHTS ARE RESERVED BY THE ENGINEER RECORD IN ACCORDANCE NTH U.S. COPYRIGHTOAND LARGO,, FLORIDA 33773 F: 727-547-9754 PATUSEENT WILL BESPROSECUTED UNAUTHORIZED THEREPRODUCTION ULLEXTENT VY Y V OUOENT OF /�Y V .AIRCO-M ECHAN ICAL.COM THE LAW. N N N r U � 2 co C_ 0 10 Cn I- �w a 8 U� 8 o J a N a U J 0 x ca LL a > e. o all 04 CID � L v Q O C 0 �t J" Cn a7 co LL 06 M Ua) a .� wi 0 O N C L r 0 c � U Q N OLl U J ILL L0 0 J J LL U 0 0 0 0 i N M 0 Z o N �a J o0 0 m M UJ O o a d. w U U 'J Q CD M CD J U_ (n J = W N Revisions: J Q UJ Q Q 2 ~ QC) W Project Number 163 Date 11-16-07 Sheet Number M-3 ROOF TOP PACKAGE UNIT SCHEDULE UNIT NO. (MARK) TOTAL SUPPLY (CFM) OUTSIDE AIR (CFM) EXT./TOT. S.P. (IN. W.G.) TOTAL CAPACITY (MBH) SENSIBLE CAPACITY (MBH) HEATING CAPACITY (MBH) ELEC. HEAT (KW/STEPS) E.A.T.(°F) L.A.T.(°F) INDOOR FAN MCA/MFS ELECTRICAL DATA (V/PH/HZ) EER DESIGN MANUF. MODEL NOTES D.B./W.B. D.B,/W.B. DRIVE HP RPM RTU-1 4,500 1,200 0.35/- 1 51 .0 87.1 92.2 27.0/2 80.8/70.0 58.0/57.2 BELT 3.0 778 108/1 1 0 208/3/60 9.8 TRANE TCD 1 51 D3 1 ,2,4 RTU-2 2,400 360 0.40/- 73.8 39.2 46.1 13.5/1 78.1 /66.5 58.0/56.6 BELT 1.0 909 53.1 /60 208/3/60 1 1 .2 TRANE TSC072E3 1 ,2,4 RTU-3 2,900 820 0.55/- 93.2 52.1 46.1 13.5/1 81 .7/70.8 58.0/57.1 BELT 2.0 856 54.8/60 208/3/60 1 1 .2 TRANE TSC092E3 1 ,2,3,4 NOTES: 1. PROVIDE 7 DAY PROGRAMMABLE THERMOSTATS LOCATION SHOWN ON PLAN. 2. PROVIDE 100% OUTSIDE AIR ECONOMIZER. 3. PROVIDE BAROMETRIC RELEIF DAMPER HOOD. 4. PROVIDE WITH MANUFACTURER'S ROOF CURB. AIR BALANCE SCHEDULE UNIT NO, (MARK) SUPPLY CFM RETURN CFM ❑UTSIDE CFM EXH, CFM TRANSFER CFM RELIEF CFM EXFIL, CFM RTU-1 4,500 3,300 1,200 0 1,000 0 200 RTU-2 2,400 2,040 360 0 300 0 60 RTU-3 2,900 2,400 820 0 500 320 0 EF-1 0 0 0 2,100 0 0 0 EF-2 0 0 0 1,000 0 0 0 EF-3 0 0 0 300 0 0 0 SF-1 0 0 1,600 0 0 0 0 VENTILATION RATE TABLE BASIS: ASHRAE STANDARD 62.1 -2004 RTU-1 DINNING ROOM: 1,804 SQ. FT. X 0.18 CFM/SQ. FT. = 324.7 CFM 116 PEOPLE X 7.5 CFM/PERSON = 870 CFM TOTAL OUTSIDE AIR REQUIRED: 1,194.7 CFM RTU-2 DINNING ROOM: 560 SO. FT. X 0.18 CFM/SQ. FT. = 100.8 CFM 35 PEOPLE X 7.5 CFM/PERSON = 260 CFM TOTAL OUTSIDE AIR REQUIRED: 360.8 CFM RTU-3 KITCHEN: 39 PEOPLE X 20 CFM/PERSON = 780 CFM DINNING ROOM: 95 SO. FT. X 0.18 CFM/SQ. FT. = 17.1 CFM 3 PEOPLE X 7.5 CFM/PERSON = 22.5 CFM TOTAL OUTSIDE AIR REQUIRED: 819.6 CFM EXHAUST FAN SCHEDULE UNIT NO. (MARK) CFM EXT. S.P. (IN H20) MOTOR RPM MAX. SONES DRIVE TYPE DESIGN MANUF. MODEL NOTES V/PH/HZ HP EF-3 1 3001 0.25 1 1 5/1 /60 1 /1 2 1,550 7.2 DIRECT INLINE GREENHECK SQ-80-D 1,2 1. PROVIDE WITH UNIT MOUNTED DISCONNECT AND GRAVITY BACKDRAFT DAMPER. 2. INTERLOCK FAN WITH RTU-1 . AIR DISTRIBUTION DEVICE SCHEDULE MARK SERVICE DESCRIPTION MATERIAL MANUF. MODEL NOTES S-1 SUPPLY SQUARE CONE DIFFUSERS ALUMINUM EH PRICE SCD 1 ,2,3 R-1 RETURN LOUVERED FACE RETURN ALUMINUM EH PRICE 630 1 ,2,3 E-1 EXHAUSTI LOUVERED FACE EXHAUST ALUMINUM EH PRICE 630 1 ,2,3 1, PROVIDE OPPOSED BLADE VOLUME DAMPER. 2. STANDARD BAKED -ON WHITE ENAMEL FINISH. 3. PROVIDE 24X24 CEILING MODULE AS REQUIRED 1 1 1 1 1 I 1 1 1 DESIGN CONDITIONS SUMMER WINTER DB('F) WB(`F) DB('F) OUTDOOR 91.4 77.5 36.6 INDOOR 75.0 62.6 68.0 1 1 1 1 1 1 1 1 1 1 1 1 i 1 1 1 1 KITCHEN HOOD SCHEDULE EXHAUST SUPPLY DESCRIPTION MARK VOLUME (CFM) SP (IN WC) DUCT COLLAR VELOCITY (FT/M) FILTER FACE VELOCITY (FT/M) VOLUME (CFM) SP (IN WC) DUCT COLLAR VELOCITY (FT/M) LENGTH WIDTH H-1 2,100 0.50 1,700 175 1,600 0.1 750 10'-0" 7'-0" FAN SCHEDULE UNIT NO. (MARK) CFM S.P. (IN H20) SF-1 1,600 0.40 EF-1 2,100 1 0.90 EF-2 11,000 1 0.40 1 i NOTE: KITCHEN HOOD SCHEDULE IS PROVIDED FOR REFERENCE ONLY. KITCHEN HOODS WILL 1 BE PROVIDED BY THE OWNER. REFER TO HOOD 1 MANUFACTURER'S DRAWINGS FOR COORDINATION. 1 1 1 HVAC LEGEND: GENERAL NOTES: SUPPLY, RETURN, AND EXHAUST DUCT 1. INSTALLATION SHALL COMPLY WITH ALL LOCAL, STATE AND FLORIDA ENERGY CODES. 2. CONTRACTOR SHALL INSTALL ALL EQUIPMENT, PIPING AND DUCTWORK SUCH THAT FLEXIBLE SUPPLY AND RETURN DUCT MANUFACTURERS' RECOMMENDED CLEARANCES ARE MET FOR ALL ACCESS PANELS, COILS, MOTORS, FANS, BELTS, FILTERS, AND AIR INTAKES. SUPPLY GRILLE 3. PROVIDE ACCESS PANELS IN ALL NON -ACCESSIBLE CONSTRUCTIONS (INCLUDING CEILING, WALLS, RETURN AND EXHAUST GRILLE ETC.) SIZED AND LOCATED AS REQUIRED TO PROVIDE PROPER SERVICE ACCESS IN ACCORDANCE WITH THE MANUFACTURERS RECOMMENDATION FOR ALL HVAC EQUIPMENT INCLUDING DAMPERS. COLLAR TAKE -OFF WITH DAMPER AIR DISTRIBUTION NOTES: OPPOSED BLADE VOLUME DAMPER 1. DUCTWORK SHALL BE FABRICATED, INSTALLED AND INSULATED PER "SMACNA" STANDARDS AND ALL LOCAL AND STATE CODES. UNDERCUT DOOR 3/40 2. DUCT SIZES ARE INSULATED SHEET METAL SIZES AND ARE "CLEAR" INSIDE DIMENSIONS. ALL DUCT 3/4" SHALL BE EXTERNALLY INSULATED WITH 2.2" THICK KNAUF DUCTWRAP WITH R=6.0 VALUE. TT THERMOSTAT 3. ROUND RUNOUTS TO GRILLES (AND BACKS OF GRILLES) TO BE WRAPPED WITH 2.2" THICK KNAUF DUCTWRAP WITH R=6.0 AND FSK JACKET (OR EQUAL). SD SMOKE DETECTOR 4. FLEXIBLE DUCTWORK TO BE ATCO RUBBER PRODUCTS (OR EQUAL) INSULATED FLEX DUCT WITH R=6.0 VALUE. X-1 DIFFUSER TAG X = S-SUPPLY CFM X = R-RETURN 5. CONTRACTOR SHALL VERIFY CLEARANCE SPACE AVAILABLE, OFFSETS REQUIRED, STRUCTURAL INK NK = NECK SIZE X = E-EXHAUST OPENINGS, AND WORK BY OTHER TRADES PRIOR TO FABRICATION OF DUCTWORK. COORDINATE WITH ROOF TRUSSES/STRUCTURE. PRESSURE TEST ALL DUCTWORK FOR LEAKS. RETURN DUCT X-# EQUIPMENT TAG SHALL BE TESTED UNDER NEGATIVE PRESSURE. X = EF - EXHAUST FAN X = H - KITCHEN HOOD EQUIPMENT NOTES: X = SF - SUPPLY FAN X = RTU - PACKAGE UNIT 1. PROVIDE FULL SIZE INSULATED CONDENSATE DRAINS FROM ALL UNITS TO NEAREST OUTLET. 2. PROVIDE A TRAP ON ALL CONDENSATE DRAIN OUTLETS. SLOPE ALL CONDENSATE DRAIN PIPING DETAIL NUMBER 1 /8" INCH PER FOOT. # 3. CONTRACTOR SHALL INSTALL ALL EQUIPMENT, PIPING AND DUCTWORK SUCH THAT MANUFACTURERS' RECOMMENDED CLEARANCES ARE MET FOR ALL ACCESS PANELS, COILS, MOTORS, FANS, BELTS, # FILTERS, AND AIR INTAKES. SHEET NUMBER WHERE SHOWN 4. ALL SMOKE DETECTION DEVICES SHALL BE INSTALLED PER LOCAL AND STATE CODES. MECHANICAL PERMIT DOCUMENTS©2007 AIRCO MECHANICAL, INCORPORATEDjl_� DESIGN. Certificate of Authorization No.: 27407 BUILD. N 0 RC THESE MECHANICAL DOCUMENTS, DESIGNS, NOTES, DETAILS, CONCEPTS ARE THE AIRCO - SOLUTION. PROPERTY OFME SOLE CHANICAL, INC. AND M E C H A N I c A L_ - SHALL NOT BE REPRODUCED, RE -USED OR COPIED FOR OR HERFE MR°tPETCMC. WRITTEN IOF`JASSON 6334 118TH AVENUE N. P: 727-547-9700 CONSENTS. M.M. BY THE ENGINEER RIGHTS ARE RESEREWITH LARGO, FLORIDA 33773 F: 727-547-9754 RECORD IN ACCORDANCEALL U.S. COPIRIGHTOAND PATUSEENT VVM.AIRCO-MECHANICAL.COM WILL BESPROSECUTEDITODTHEPRODUCTINULL EXTOENTND OF THE LAW. N 't r aj N V U °° C 0 co CU coo �w a � U04 JT N U J 0 00 C Lw a > .. o 2 C; co C s N 0 o�Q _ `C a J" 06LL E UL a 0 O N 0 0 0 0 _ c Q N J O� O J o _J J U 0 M 0 0 0 N Q N It M CM OLL z o Q N mp Q 0 CO 0 UJ o o � U Z] (� 00 (� J U_ J W N Revisions: W J � Z Cl W _ (D W W � J Q Q U_ Z U) Q W =0 W Z 2 Project Number 163 Date 11-16-07 Sheet Number M -4 HANGING Af 3' UNINSULATED STANDOFF , -1w vvv ----- , , 15,0000" P-9I1I1I1I1Iw 60,0000' - 30.0000' 30,0000' 30.0000' 15,0000' 10' 0,00" PLAN VIEW - 10' 0,00" LONG 693OND-PSP-E HOOD INFORMATION I // r Tri Tl Th ICI T A 1 1 r T% CN-r A Tk 11 r C� e" e" Tr ri rk IrN I r-1 e' 1 If'%r SECTION VIEW — MODEL 6930—ND with PSP Accessory HOOD NO. MODEL LENGTH MAX, COOKING TEMP, EXHAUST PLENUM SUPPLY PLENUM HOOD CONSTRUCTI❑N HOOD C❑NFIG, FILTER(S) LIGHT(S) FIRE SYSTEM PIPING HOOD HT TOTAL EXH, CFM RISER(S) TOTAL SUP. CFM RISER(S) END TO END ROW TYPE QTY, HEIGHT LENGTH QTY, TYPE WIDTH LENG, DIA, CFM S,P, WIDTH LENG, DIA, CFM S.P. 1 6930 ND-PSP-F 10' 0.00'Nom. 10 0,50 ❑D 450 Deg, 2100 10' 19" 2100 0,457' 1600 430 SS Exposed ALONE FRONT Alum Baffle w/ Handle 6 16' 20" 3 Incandescent Light NO 550 LBS, F I IWhere PERFORATED SUPPLY PLENUM(S) HOOD NO, POS, LENGTH WIDTH HEIGHT RISER(S) WIDTH LENG, DIA. CFM S.P. 1 Front 120,00' 12,00' 6,00' 10" 400 0,097" 10' 400 0,097' 10" 400 0,097' 10" 400 0,097" FOR QUESTIONS, CALL THE REG 45 ❑FFICE IN DALLAS 3402 DAK GROVE AVE,, STE 302, DALLAS, TX 75204 PHONE: (214) 220-3999, (800) 833-3786 FAX (214) 220-0099 HOOD OPTIONS HOOD OPTION NO. 1 BACK STANDOFF 3' Wide AO A JOB CICPs Proto Full Store Std T2 LOCATION ZEPHYRHILLS, FLORIDA DATE 6/4/07 JOB # DXC Jj M-5 PRA X-1V BY C J P - 4 5 REV 6,0 SCAYLE N T S PIZZA HOOD UNTEMPERED SUPPLY BAN MODULAR OUTDOOR DOWN DISCHARGE BLOWER WITH INTAKE HOOD DIM "D" 11 DIM OF" 20 IN HIGH EQUIPMENT CURB ,,,,,,-LIFTING LUG D I M " G "' �-� DIM "B" ALL DIMENSIONS ARE NOMINAL AND GIVEN IN INCHES. DIM "R" DIM "L" CURB - OUTER WAL DIM "C" DISCHARGE rlr-%r-A ITA Ir D I M "G" ----� DIM "E" SERVICE DISC❑NNFCT ROOF OPENING 2" SMALLER THEN CURB DIMENSION, UNIT DIMENSIONS DISCHARGE OPENING UNIT INFORMATION CFM RANGE MODEL WEIGHT A B C D E F G L M N R FILTER SIZE & QTY MIN MAX MAX, FILTER VELOCITY G10 250 LBS 32-1/8 27-3/8 29-3/4 26-1/16 44-3/8 3-3/4 21 13 1/4 11-1/2 3-7/8 1-3/4 16'x20'x2' (3) 0 3500 @3500 CFM = 667 FPM FAN INFORMA TION FAN UNIT FAN UNIT MODEL # SUPPLY FAN NO. BLOWER HOUSING TAG CFM S.P. RPM H.P. 0 VOLT FLA 2 Al-G10D G10D Al SF-1 1600 0.400' 781 0.500 1 115 6.8 PIZZA SUPPLY FAN FOR QUESTIONS, CALL THE REG 45 ❑FFICE IN DALLAS 3402 OAK GROVE AVE,, STE 302, DALLAS, TX 75204 PHONE: (214) 220-3999, (800) 833-3786 FAX: (214) 220-0099 PIZZA HOOD EXHAUST FAN DUHFA SERIES UPBLAST EXHAUST FANS (UL705) 2G FEATURES: - ROOF MOUNTED FANS - RESTAURANT MODEL - UL705 - VARIABLE SPEEDCONTROL - INTERNAL WIRING - WEATHERPROOF DISCONNECT - THERMAL OVERLOAD PROTECTI❑N (SINGLE PHASE) - HIGH HEAT OPERATION 300°F (149°C) - GREASE CLASSIFICATION TESTING NORMAL TEMPERATURE TEST EXHAUST FAN MUST OPERATE CONTINUOUSLY WHILE EXHAUSTING AIR AT 300°F (149°C) UNTIL ALL FAN PARTS HAVE REACHED THERMAL EQUILIBRIUM, AND WITHOUT ANY DETERIORATING EFFECTS TO THE FAN WHICH WOULD CAUSE UNSAFE ❑PERATION, ABNORMAL FLARE-UP TEST EXHAUST FAN MUST OPERATE CONTINUOUSLY WHILE EXHAUSTING BURNING GREASE VAPORS AT 600°F (316°C) FOR A PERIOD OF 15 MINUTES WITHOUT THE FAN BECOMING DAMAGED TO ANY EXTENT THAT COULD CAUSE AN UNSAFE C❑NDITI❑N, OPTIONS: HINGED FAN PITCHED CURB INSULATED CURB DUCTWORK BETWEEN EXHAUST RISER ON HOOD AND FAN (BY OTHERS) DUH DIRECT DRIVE CENTRIFUGAL UP -BLAST EXHAUST FANS DIMENSIONAL DATA FAN MODEL HT W B C F R R❑ ✓EIGHT LB DU85HFA 30 1/2 31 7/8 2 24 3/4 23 14 7/8 21 60 FAN INFORMA TION FAN UNIT FAN UNIT MODEL # EXHAUST FAN NO. MODEL TAG CFM S,P, RPM H,P, 0 VOLT FLA 1 DU85HFA DU85HFA EF-1 2100 -0,900" 1381 0,750 1 115 13.0 PIZZA EXHAUST FAN CURB ASSEMBLIES N❑, FAN ITEM SIZE 1 # 1 Curb 23,000'W x 23,000'L x 20,000'H Vented PITCHED CURBS ARE AVAIL4 FOR PITCHED ROOFS, SPECIFY PITCH; 12 EXAMPLES 7/12 PITCH = 30° SLOPE CURB DIMENSIONAL DATA FAN MODEL D E DU85HFA 23 20 AO % w AV m Aw L04400i I w -- �llU� 7 VENTED CURB ?0 GAUGE JEEL ;ONSTRUCTION / ROOF OPENING R❑ RD �� DIMENSIONS CICI's Proto Full Store Std T2 LOCATION ZEPHYRHILLS, FLORIDA RA_ 77E 6/4/07 Dfrc # M-6 REV 6,0 JOB # DRA ff/V BY C J P - 4 5 SCALE N T S PASTA/DISH EXHAUST FAN FEATURES: DUHFA SERIES UPBLAST EXHAUST FANS (UL705) Ro 26 - ROOF MOUNTED FANS - RESTAURANT MODEL - UL705 - VARIABLE SPEED CONTROL - INTERNAL WIRING - WEATHERPROOF DISCONNECT - THERMAL OVERLOAD PROTECTION (SINGLE PHASE) - HIGH HEAT OPERATION 300°F (149°C) - GREASE CLASSIFICATION TESTING NORMAL TEMPERATURE TEST EXHAUST FAN MUST OPERATE CONTINUOUSLY WHILE EXHAUSTING AIR AT 300°F (149°C) UNTIL ALL FAN PARTS HAVE REACHED THERMAL EQUILIBRIUM, AND WITHOUT ANY DETERIORATING EFFECTS TO THE FAN WHICH WOULD CAUSE UNSAFE OPERATION, ABNORMAL FLARE-UP TEST EXHAUST FAN MUST OPERATE CONTINUOUSLY WHILE EXHAUSTING BURNING GREASE VAPORS AT 600°F (316°C) FOR A PERIOD OF 15 MINUTES WITHOUT THE FAN BECOMING DAMAGED TO ANY EXTENT THAT COULD CAUSE AN UNSAFE CONDITION, OPTIONS: HINGED FAN PITCHED CURB INSULATED CURB DUCTWORK BETWEEN EXHAUST RISER ON HOOD AND FAN (BY OTHERS) DUH DIRECT DRIVE CENTRIFUGAL UP -BLAST EXHAUST FANS DIMENSIONAL DATA FAN MODEL HT W B C F R R❑ ✓EIGHT LB DU50HFA 27 1/4 28 7/8 2 21 21112 13 1/4 17 1/2 55 FAN INFORMATION FAN UNIT FAN UNIT MODEL # EXHAUST FAN NO, MODEL TAG CFM S.P. RPM H.P. 0 VOLT FLA 3 DU50HFA DU50HFA EF-2 1000 -0.500' 1102 0,500 1 115 6.3 DISH/PASTA EXHAUST FAN CURB ASSEMBLIES NO, ON FAN ITEM SIZE 3 # 3 Curb 19,500°W x 19,500"L x 20.000"H Vented PITCHED CURBS ARE AVAILF FOR PITCHED ROOFS, SPECIFY PITCH; 12 EXAMPLE: 7/12 PITCH = 30° SLOPE CURB DIMENSIONAL DATA FAN MODEL D E DU50HFA 19 1/2 20 wilial-fir 7 VENTED CURB '0 GAUGE JEEL 'ONSTRUCTION LnIVI�E / ROOF OPENING RO R❑ �� DIMENSIONS CICI's Proto Full Store Std T2 FOR QUESTIONS, CALF THE _ _ _ _ LOCATION ZEPHYRHILLS, FLORIDA A� REG 45 OFFICE IN DALLAS i / M/_PA TE 6/4/07 JOB 3402 OAK GRAVE AVE,, STE 302, DALLAS, TX 75204 PHONE: (214) 220-3999, (800) 833-3786 L04400I w DIFC # M-7 D1?,4XA1_ BYCJP-45 FAX: (214) 220-0099 REV (,0 SCALE N T S A-7,9,1 3/4' T a TH & ClU MEN TH & #10 110 _ D =1 B-30 RTU-2 IDa�l0 3 �13R O r - 1 o HALL III I WOMEN 109 I - -- ---- - - - =-- ---- li B-7 B-9 GAME ROOM B-4 108 B-13 31 B-17 a A-14 1 __�_ II \ 1 PREP, KITCHEN 105 B-15 J 1 GFI 2 52 21 34 B-23 3 ff 3R A-19,21,23 3, '5 RTU-3 O35 B-10 833/4' EMT W/3 1:82 #6 CU THWN & B-8 1 #10 GRND 0 33 73 B-21 B-19 ' 16 30 46 7 41 15 14 25 1 44 )(43) BEV. A-18 A-16 STATION 106 A-32,34 B-23 i �� -- — ---- P GFI B-281 N ROOF DINING 1 I Q� y A-24 107 A-1,3,5 RTU-1 3 3R 2' EMT W/3 #3/0 B CLG. I ����! CU THWN & 1 #6 GRND 3I-B R-3 a-B I-B U E3 71 0 L ELECTRICAL POWER PLAN SCALE, 1/4' = 1'-0' aD Ee 101 6 A-20,22 B-37 5 30 A-12 B-35 7 BJ33 SF-1 7 J ISPLAY 8 KITCHEN A-24,26 102 SERVING 1 33 A-28,30 20 17 B-29 23 22 54 � 5 I B-12 B-14 , I 5 I 5 ZA 24 I P B- 6 I 5 EF-1 81 , A-12 B-18 , 14 FF_ I B-22 I GFI 3 I 4 I B-20 I 4 84 I I 16 B-27 ORDER 101 B-25 72 71 71 I n 1 I ENTRY 100 GENERAL NOTES & SPECIFICATIONS DIVISION SIXTEEN - ELECTRICAL POWER, LIGHTING & TELECOMMUNICATIONS 1. THE CONTRACTOR SHALL FURNISH ALL MATERIAL, LABOR, TOOLS, EQUIPMENT AND WORK REQUIRED FOR INSTALLATI❑N OF A COMPLETE ELECTRICAL SYSTEM, INCLUDING LIGHTING AND POWER DISTRIBUTI❑N, AND TELEPHONE C❑NDUITS AS INDICATED ON THE DRAWINGS, ALL MATERIALS SHALL BE NEW AND BEAR UNDERWRITERS LAB❑RATORIES APPROVAL, ALL WORK MUST MEET APPROVAL OF THE N.E.C. AND ALL OTHER APPLICABLE CODES AND INSPECTING AUTH❑RITIES. 2. SWITCHES CONTROLLING PANELS, LOAD CENTERS, OR MOTORS SHALL BE HEAVY DUTY SQUARE D OR APPROVED EQUAL, MULTIPLE MAINS SHALL BE IDENTIFIED AS MAIN #11 MAIN #2, ETC. FUSES SHALL BE BUSSMAN CLASS RK-1 AND CLASS L OR APPROVED EQUALS, 3. MAIN SWITCHES AND MAIN PANEL BOARDS SHALL BE SUITABLE FOR SERVICE ENTRANCE EQUIPMENT WITH A SHORT CIRCUIT CURRENT DESIGN OF 65,000 A.I.C. C SYM,), WHICH WILL BE VERIFIED WITH LOCAL UTILITY. 4, PANELBOARDS TO BE Q.O. OR APPROVED EQUAL WITH LOCKING DOOR UNLESS OTHER SPECIFIED. INSTALL TYPEWRITTEN, TWO —COLUMN DIRECTORIES INSIDE EACH NEW AND RELOCATED PANELBOARD INDICATING WHAT EACH CIRCUIT SERVES, THE CONTRACTOR SHALL BALANCE THE LOADS IN THE WIRE GUTTER AND IN THE PANELB❑ARDS, 5. WORK SHALL BE DONE IN A NEAT W❑RKMANLIKE MANNER BY EXPERIENCED JOURNEYMEN ELECTRICIANS. 6. ANY MIN❑R WORK NECESSARY, ALTHOUGH NOT SHOWN, TO MAKE THIS A COMPLETE ELECTRICAL INSTALLATION SHALL BE C❑NSIDERED A PART OF THE CONTRACT, 7, ALL WIRE TO BE COPPER AND NO WIRE SMALLER THAN #12 AWG GAUGE SHALL BE USED ON THIS INSTALLATION, S. VOLTAGE CHARACTERISTICS ARE 120/208 V 9. THE CONTRACTOR SHALL VERIFY THE ELECTRICAL REQUIREMENTS OF ALL EQUIPMENT PRI❑R TO ROUGH -IN. IF THE ELECTRICAL CHARACTERISTICS OF THE EQUIPMENT VARIES FROM THAT SPECIFIED ON THE ELECTRICAL DRAWINGS, IT SHALL BE THE RESP❑NSIBILITY OF THE SUPPLIER TO N❑TIFY THE ARCHITECT OF ANY CHANGES TO THE ELECTRICAL SYSTEM, 10, ALL ELECTRICAL WORK SHALL CONFORM TO THE LATEST REVISI❑N OF THE N,E.C, AND LOCAL GOVERNING C❑DES, 11. ALL MATERIALS WHERE APPLICABLE SHALL BE U.L. LABELED. 12, CONTRACTOR SHALL VERIFY LOCATION AND ELECTRICAL REQUIREMENTS OF ALL EQUIPMENT FURNISHED BY OTHER TRADES PRIOR TO INSTALLING WIRE AND CONDUIT. SYMBOL LEGEND 2' X 4'3 LAMP LAY -IN FIXTURE, W/ELECTRONIC BALLAST, T-8 LAMPS, 120V 18 CELL PARABOLIC ❑0 2'X 2' LAY -IN FIXTURE 120V 9 CELL PARABOLIC B 2'X 4' LAY -IN FIXTURE 120V STANDARD 4 LAMP LAY -IN 8' 2 LAMP FIXTURE WITH LAMPS ELECTRONIC BALLAST T-8 LAMPS BATTERY PACK 2 HEAD EMERGENCY LIGHT BATTERY PACK C❑MBINATI❑N EXIT / 2 HEAD EMERGENCY LIGHT �0 SURFACE MOUNT WALL BRACKET FLOURESCENT FIXTURE B 175W METAL HALIDE WALL PACK FICTURE MULTI -TAP BALLAST 0 RECESSED INCANDESCENT DOWN LIGHT 75W 120V L7X W/ 602A TRACK LIGHTING ALUMINUM TRACK AND ALUMINUM FIXTURES RECESSED FLOURESCENT FIXTURE 52W LF62/26 DTT MV❑LTGEB10 DUPLEX RECEPTACLE, 20A 18' CL A.F.F. DUPLEX RECEPTACLE. 20A 46' CL A,F,F, QUAD OUTLET 2 DUPLEXES 20A 46' CL A.F.F. Q TELEPHONE/DATA OUTLET 18' CL A,F.F, OR AS NOTED PR❑VIDE BOX, P. RING, AND 3/4'C. TO ABOVE CEILING TELEPHONE/DATA OUTLET 46' CL A.F.F. OR AS NOTED PROVIDE BOX, P, RING, AND 3/4'C, TO ABOVE CEILING JQ JUNCTION BOX MI FLEXIBLE C❑NNECTION WP WEATHERPROOF GFI GROUND FAULT CIRCUIT INTERUPTER $ SINGLE POLE SWITCH. 20A 46' CL A.F.F. $3 3-WAY SWITCH 20A 46' C. A,F,F, SINGLE POLE DIMMER 60OW, 46' A,F,F. TELEVISION/SATALITE ® 220 V DISC. SWITCH FURNITURE AND EQUIPMENT SCHEDULE #1 NO. DESCRIPTION MANUFACTURER MODEL NO. SIZE WXDxH FURN. INSTALL VOLT PH HP AMP CONN, DRAIN CW* HW* GAS BTU REMARKS NO. DESCRIPTION MANUFACTURER MODEL NO. SIZE WXDXH FURN. INSTALL VOLT PH HP AMP CONN. DRAIN CW* HW* GAS BTU REMARKS I WIRE SHELVING ISS SHELVING VARIES TENANT G.C. 44 ICE TEA MAKER BUNN T6 17X17X29 TENANT G.0 120 1 114.87 PLUG 1 1/4' 2 DUNNAGE RACK ALUM SPECIALIST VARIES TENANT G.C. 3 PORTABLE RACK NEW AGE INDUST. 6301 20 1/2X27 1/2X69 TENANT G.C. 46 CARBONATOR GENERIC COKE COKE 120 1/2, 4 WIRE SHELF (CUT TABLE) ISS SHELVING (2) 18 X 48 TENANT G.C. 51 CONVEYER OVEN LINCOLN 1600 75 1/4X 58 3/4 TENANT G.C. 120 1 14 PLUG/ EACH DECK 3/4 110000 EA 5 PIZZA PAN WALL RACKS --- --- --- TENANT G.C. 52 DOUGH MIXER HOBART P-660 27 1/2'X39 1/4' TENANT G.C. 208 3 2.5 8.6 DIRECT 6 UNDERCTR, SUSP, WIRE SHELF ISS SHELVING --- 24X48 TENANT G.C. 53 PASTA COOKER FRYMASTER BBC 18X32 3/049 TENANT G.C. 208 1 39 PLUG 3/8' 3/8 7 SYRUP RACK ISS SHELVING --- 1SX48 TENANT G.C. 54 DOUGH PRESS PROPROCESS CORP. DP-1100 17XISX25 TENANT G.C, 120 1 12.5 PLUG 14 30' HEATED SHELF HATCO GRSB-30-F 17x30 1/2 TENANT G.C. 120 1 4.2 PLUG 55 COOLER KOLPAK CICI 7'-9'X34'-5 1/2'X8'-4' TENANT G.C. 230 1 1 DIRECT 15 18' HEATED SHELF HATCO GRSB-18-F 17x19 1/2 TENANT G.C. 120 1 2.8 PLUG CONDENSING UNIT KOLPAK PCL 145M TENANT G.C. 208 3 1 1/3 10.7 DIRECT 16 LIGHTED FOOD GUARD HATCO --- 18x100 E SALAD BAR TENANT G.C. 120 1 4.0 DIRECT EVAPORATOR COIL KOLPAK HM-145 TENANT G.C. 120 1 4.2 DIRECT 1' COPPER DRAIN 17 ILIGHTED FOOD GUARD HATCO --- 18x54 2 PASTA BAR TENANT G.C. 120 1 2.5 DIRECT 61 WATER HEATER STATE SBN75-120 NE 2SX75 G.C, G.C. 120 1 DIRECT POP OFF TO 1' 1' 3/4 120000 18 LIGHTED FOOD GUARD HATCO --- 18428 2 WARMERS TENANT G,C, 208 1 13.6 DIRECT PROVIDE SEPARATE NEUTRAL FOR LIGHTS 62 CO2 TANK VENDOR G,C, 19 LIGHTED FOOD GUARD HATCO --- 18x105 2 WARMERS TENANT G.C. 208 1 12.4 DIRECT PROVIDE SEPARATE NEUTRAL FOR LIGHTS 71 P.O.S. REGISTER TENANT G.C. 120 1 2.0 PLUG 20 HOT FOOD WELLS APW/WYOTT HFW-4 WELL 58-1/2x23-7/16x56-7/8 TENANT G.C. 208 6 23.1 E.C. TO FURN & INST CORD CAPS. COPPER DRAINS W/SHUTOFFS 72 SAFE ROLLAND #2015 20'Hx15'Wx15'D TENANT G.C. 21 8' WORK TABLE (PREP) TABCD AS SERIES 30X96 TENANT G.C. 73 81 TIME CLOCK AMANO 3500 SERIES 8 1/4X10 1/2X6 TENANT G.C. 120 1 0.3 PLUG 22 6' WORK TABLE (STRETCH) TABCD SG SERIES 30X72 TENANT G.C. TYPE II OVEN HOOD MASTER AIR INC. CICI-A 9'-0'X6'-0'X2'-6' TENANT G.C. 120 1 2 DIRECT 23 7' WORK TABLE (CUT) TABCD AS SERIES 30X84 TENANT G.C. EXHAUST FAN SEE MECH. DWGS. --- --- --- 24 PIZZA MAKE TABLE DELFIELD 186114PTB 31.5 X 114 TENANT G.C. 120 1 3/4 14.0 PLUG SUPPLY FAN SEE MECH. DWGS. --- --- --- --- --- 25 27 4' HEATED SHELF 6' HEATED SHELF HATCO HATCO GRSB-48-F GRSB-72-F 19X49 1/2 17x73 1/2 TENANT TENANT G.C. G.C. 120 120 1 1 6.4 9A PLUG PLUG 82 63 SPLASH GUARDS PAPER TOWEL DISPENSER ADVANCE TABCD VARIES (COORD. WITH ADJACENT SINK DIMS.) TENANT TENANT G.C. G.C, --- -- --- --- --- SEE SHEET A3 28 SALAD DISPLAY UNIT (ROLL -IN) McCALL 93 i/8x34x34 TENANT G.C. 120 1 1/2 1 16.0 PLUG 84 TAKE OUT PIZZA WARMER FWE TS-1633-36 25,25x37.25x69 TENANT G.C. 120 1 2 11.3 PLUG 91 GAME TENANT G.C. 30 4' UNDERCOUNTER WARMER HATCO GRSB-48 19 1/2x48 TENANT G.C. 120 1 8.3 PLUG 92 COIN CHANGER TENANT G.C. 31 DISHWASHER & TABLE EC❑LAB T.B.D. TENANT G.C. 1 3/4 PLUG 2' INDIRECT 3/4 EXT D LEGS TO FULL HT, 93 WALL HUNG TRINKET MACHINE TENANT G.C. 32 3-COMPARTMENT SINK w/ PRE -RINSE (BOWL SIZE = 20'x20'x14'j DRAIN BOARD SIZE (INTEGRAL) = 36'x271) ADVANCE TABCD 9-23-60-24RL 115X27 TENANT G.C. 2' INDIRECT 1/2' 1/2' 95 TELEVISION GENERIC 36' TENANT G.C. 120 1 3,0 PLUG INCL SUSP'N BRKT 97 DINING TABLE (4 TOP) TENANT G.C. 33 HAND SINK ADVANCE 7-PS-50 17 3/4 TENANT G.C. 1 1/2' DIRECT 1/2, 1/2, 98 DINING TABLE (2 TOP) TENANT G.C. 34 MOP SINK FIAT MSB 2424 24X24 G.C. G.C. 3' DIRECT 1/2' 1/2' 101 BOOTH TABLE (4 TOP) TENANT G.C, 35 PREP SINK ADVANCE TABCD T9-21-20 40X24 TENANT G.C. 2' INDIRECT 1/2' 1/2' 103 BOOTH SEATING (SINGLE) TENANT G.C. 41 ICE MACHINE w/ REMOTE CONDENSING UNIT SCOTSMAN CME 506 /HTB 550 42X31.5 TENANT G.C, 120 1 19 PLUG 1/2'INDIRECT 3/8' 104 BOOTH SEATING (DOUBLE) TENANT G.C. 105 WALL GRAPHICS TENANT G.C. 42 ICE MACHINE - SELF CONTAINED ISCOTSMAN lCME 656 TENANT G.C, 208 1 19 PLUG 1/2-INDIRECT 1 3/8' 106 IMENU BOARDS TENANT G.C, 43 DRINK DISPENSER COKE DUR FLEX 50 3 X30X 9 COKE COKE 120 ■ ALL WATER CMMCTUM FROM STOP VALVE M EQUIPMENT SHALL BE WOVEN STEEL MESH FLEXIBLE LINES. U) C M J _2 o -` o a 0 c E Vr o 0 cE N 0 JN ao °� °, U 11 C CDc o m c > n r` o O 04 ^ N � VJ/ U C :? 0 Q O z a � o J M Cl) J LL 0 L w r� a V a. > o 0= to 0 O w 0)z o coN ' CD Q > c N J m y J Z 0 N O P_ J LJ U .. O 0 0 0 N < LO o NwJJ > M z N < O 0- m J w U �Q� =CL a U �_ WooW N co N Revisions: w W O - 0- Q � - J N O _U a o U w J W Project Number 07059 Date 02-28-08 Sheet Number E-1 _ 1 ' 1 I '_L9 I I I _ _ I __ L I I I I I I I I I I I i i I L- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - J L - - - - - - --- - - - - - - - - - - - J L - - - - - - - - - - - - - - - - - - - B-26 ELECTRICAL LIGHTING PLAN SCALES 1/4' = 1'-0' a D A SQD _ TYPEISQD__ NEMAI SQD _ MTDI S ____ SPACESt42__ VOLTI 120/208 PHI 3 _ WIRESI_4__ GRN, BARI Y AMPS160D _MAIN LUG_______ FEEDER WIRES 2 SETS 3' CONDUIT W/ 4 350 MCM THWN & 1 #1 GRND CIR AMP P LOAD KW WIRE # CIR AMP P LOAD KW WIRE # 1 175 3 RTU-1 55.5 #2/0 2 20 3 WALK IN COMP 3,9 #12 3 4 5 6 7 50 3 RTU-2 15.6 #8 8 20 1 WALK IN COIL .5 9 10 20 1 WALK IN LIGHTING .2 it 12 20 1 EF-1 1,6 13 60 3 RTU-3 19.8 #6 14 20 1 EF-2 18 15 16 20 1 HEATED SHELF 5 17 18 20 1 HEATED SHELF .4 19 20 3 MIXER 3.1 #12 20 20 2 LTG FOOD GUARD 2.6 21 22 23 24 20 2 LTG FOOD GUARD 2.8 25 SPARE 26 27 SPARE 28 30 2 HOT FOOD WELLS 4.8 #10 29 SPARE 30 31 SPARE 32 30 2 ICE MACHINE 4.0 33 SPARE 34 SELF-CONTAINED 35 SPARE 36 30 1 ICE MACHINE 2.3 37 SPARE 38 150 3 PNL B 27.3 #1/0 39 SPARE 40 41 SPARE 42 145,700 / 360 = 405 AMPS PNF1. B SAD TYPEINQOD_ NEMAt1____ MTDIS ____ SPACESI 42__ VOLTI 120/208 PHI 3 _ WIRESt 4 _ GRN. BARI Y AMPS1200__MAIN LUG_______ FEEDER WIRES 2' CONDUIT W/ 4 1/0 CU THWN & 1 #6 GRND CIR AMP P LOAD KW WIRE # CIR AMP P LOAD KW WIRE # 1 20 1 BATH/GAME LTG 1 #12 2 20 1 DINING LTG .8 #12 3 20 1 KITCHEN LTG 1.6 14 20 1 SERVING LTG 1.5 5 20 1 DINING LTG .7 6 20 1 DINING LTG 1.5 7 20 1 GAME RM RECEPT 5 8 20 1 HW PILOT .1 9 20 1 GAME RM RECEPT .5 10 20 1 CONY, RECEPT .2 11 20 1 GAME RM RECEPT .5 12 20 1 DOUGH PRESS 1.5 13 20 1 GAME RM RECEPT 5 14 20 1 CONY, RECPT .8 15 20 1 CORR. RECEPT 18 16 20 1 PIZZA TABLE 1.7 17 20 1 DISHWASHER 1.6 18 20 1 CONVEYOR OVEN 1.7 19 20 1 CARBONATER .2 20 20 1 PIZZA WARMER 1.4 21 20 1 PREP RECEPT .2 22 20 1 CONY. RECEPT .2 23 20 1 CORR, RECEPT ,8 24 20 1 ROOF RECEPT .2 25 20 1 CASH REGISTER .6 26 20 1 SIGN CIRCUIT 1.2 27 20 1 LT FOOD GUARD .5 28 20 1 TELEVISI❑N .36 29 20 1 LT FOOD GUARD .3 30 20 1 EWC .36 31 20 1 SALAD DISPLAY 2.0 32 33 20 1 HEATED SHELF 1.2 34 35 20 1 UND, COUNT WARMER 1 36 37 20 1 HEATED SHELF 1.2 38 39 40 41 42 2 E-2 28,860 / 360 = 812 AMPS EXIST. PNL "A" EXIST, NEW O 600A ML PNL 'B' 120/208 V 1ML 0 ML 120/208V 600A E MAIN BREAKER 2' NIPPLE W/ 4 1/0 CU THWN & 1 #6 GRND. EXISTING 2 SETS 3" PVC W/ 4 350 MCM & 1 #1 EACH ELECTRICAL RISER DIAGRAM SCALES N.T.S. � M LO M cQ 0 a c E E U� � N yy C °° ces >°, c U ' JtM 0 (L o N W J/)�� c/ U, ~ Y c U N c O s a 0 JM J LL 0 .n d a M Or In O z 00 o a c J O N 0 E 4) J C J O ti J Lj_ U 0 t- 0 0 N Ln J O > cM W uj ZN Q=LL O -�mJ w () �Q� WccooW N c0 N Revisions: V _z in V J Z o. w J W Project Number 07059 Date 02-28-08 Sheet Number E-2 I II _ 1 1 "PI111 III oil 'I ' _.I_ I _ _ _ I 1 _ _A I I I I I I I I L — — — EXIST. SHELL f SPRINKL RISER HANGER DETAIL SCALES NTS 1 FIRE SPRINKLER PLAN S-11 SCALES 1/4' = 1'-0' 8 TO SPACES GENERAL NOTES & SPECIFICATIONS SCAPOE 13F W❑RKI 1. THIS IS AN EXISTING TENANT FIRE SPRINKER SYSTEM MODIFIED TO ACC❑M❑DATE THIS TENANT. 2, HANGERS = 3/8 T,B.C„ 3/8 ROD AND HANGER - SEE DETAIL. 3, LAYOUT BASED ON NFPA 13 ORDINARY HAZARD. 2002 EDITI❑N FIRE SPRINKLER LEGEND — — — — — EXISTING PIPING NEW 1' SCH, 40 PIPE EXISTING SHELL UPRIGHT TO BE RELOCATED 35 R O RELOCATED EXISTING UPRIGHT W/ NEW 155' GR PENDANT HL WHITE SEMI -RECESSED 5 A Q NEW 155. 1/2' OR PENDANT HL WHITE SEMI -RECESSED 1 ® DRY PENDANT HL 155. 1/2' OR 8 U� � y C' C CID o T C U M c _m m (L o_ 04 N ♦ ^ S v j SZ � m ti � Q 0o r a 0 J LL 0, 06 a Ua in M 0 p Z C O C (Op Q C O d J 0 U C Q LID _J O J P_ LJL U . tin C O I` O O N J > CV) � o � w w J QD - N O ( � CO E� w J = QQ� a U r CLtM� wcow NQ0N Revisions: z Q w J E Project Number 07059 Date 02-28-08 Sheet Number FS-1