Loading...
HomeMy WebLinkAbout6901 Gall Blvd (2)GreenberUFarrow 1430 West Peachtree Street Atlanta, GA 30309 t: 404 6014000 f. 404 6013980 COPYMORT NOTICE This drawing is the property of the above referenced Professional and is not to be used for any purpose other than the specific project and site named herein, and cannot be reproduced in any manner without the express written permission from the Professional ISSUE/REVISION RECORD DATE DESCRIPTION 12/5/07 ISSUED FOR PERMIT �cw1 c oA- * L�lLOaTSSkj PROFESSIOUAL STEAL PROFESSIONAL IN CHARGE JUSTIN HARDY, P.E. 67084 PROJECT MANAGER STEVE ALLEN QUALITY CONTROL AMY HADLOW P.E. DRAWN BY STEVE ALLEN PROJECT NAME NAPA AUTO PARTS ZEPHYRHILLS FLORIDA 6901 GALL BOULEVARD 4 NDAPA s�— PROJECT NUMBER 20070208 SHEET TITLE MECHANICAL PLAN SHEET NUMBER M1.0 1 M2.0 ►•'FAU lli HVAC DETAIL SCALE: NOT TO SCALE l'� 1A X 1A ISM MOMP Ni uwi .=. b WD 1 RTU DETAIL M 2.0 / SCALE: NOT TO SCALE or tr �Wll DINATE DUCT ROUTING JGH OPEN WEB JOISTS. PROVIDE CHASE I1� H.V.A.C. DUCT TO ELECTRICAL ROOM. FLOOR FRAMING OFFICE AND ROOFTOP OHEAT PUMP M P UNIT SCHEO LE UNIT DESCRPTTON ST R c NG CAPACITY HEATING CAPACITY POWER TRANE MODEL REMARKS SUPPLY OA MIN TOTAL SENSIBLE KW OUTPUT MTR HP VOLTAGE MCA/MCOP RTU-1 PACKAGED ROOFTOP UNIT W/ HEAT PUMP 4000 CFM 550 CFM 0.5 IN 121.0 MBH 94.8 MBH 9.59 108 MBH 2 HP 208-3-60 50.4/60 WSC120A3 1, 2, 3, 4, 5 RTU-2 PACKAGED ROOFTOP UNIT W/ HEAT PUMP 4000 CFM 550 CFM 0.5 IN 121.0 MBH 94.8 MBH 9.59 108 MBH 2 HP 208-3-60 50.4/60 WSC120A3 1, 2, 3, 4, 5 REMARKS: 1. PROVIDE UNIT WITH ROOF CURB, DISCONNECT, 115V GFI SERVICE OUTLET, AND LOW AMBIENT COOLING CONTROL. 2. RTU'S FAN SHALL BE SET TO RUN IN CONTINUOUS MODE. 3. COOLING/HEATING RATED AT 80/67 T AND AMBIENT 95 'F. 4. PROVIDE RTU UNIT WITH ELECTRONIC PROGRAMMABLE THERMOSTAT. 5. REFER TO SPECIFICATION FOR ADDITINAL INFORMATION. EXHAUST FAN SCHEDULE ELECTRICAL OPER MARK LOCATION MFR MODEL CFM S.P. WT REMARKS H.P. VOLT/PH/HZ IN W.G. LBS EF-1 WOMENS RESTROOM LOREN COOK GC-164 100 0.625 145 WATTS 120 1 60 15 1,2,3,4 EF-2 MEN'S RESTROOM LOREN COOK GC-164 100 1 0.625 1 145 WATTS 120 1 60 15 1,2,3,4 REMARKS: 1. PROVIDE FACTORY INSTALLED DISCONNECT SWITCH AND BACKDRAFT DAMPER. 2. CONNECT THE EXHAUST FAN TO THE LIGHT SWITCH 3. PROVIDE GEMINI MODEL ROOF CAP. 4. FAN SHALL BE INTERLOCKED WITH LIGHT SWITCH DIFFUSERS REGISTERS GRILLES & LOUVERS UNIT SIZE THROW MODEL OUTLET DAMPER FINISH FRAME REMARKS INCHES (1) CONNECTION (4) SA -A 12X12 4 WAY SMD 1 4A/B12/SR3 10" YES WHITE SM 1,2,3,4 SA-B 10x10 2 WAY SMD/1 /4A/B1 2/SR3 10" YES WHITE SM 1,2,3,4 REMARKS: 1. E.H. PRICE. 2. PROVIDE SQUARE TO ROUND NECK ADAPTER WITH DAMPER. EH PRICE MODEL SR3. 3. INDEPENDENTLY SUPPORT ALL DIFFUSERS, REGISTERS, AND GRILLES FROM STRUCTURE. DO NOT REPLY ON CEILING TILE OR GRID. 4. TB=LAY-IN TEE BAR OR SM=CUT-IN SURFACE MOUNTED W/FLANGE AS REQUIRED. FIELD VERIFY. GENERAL NOTES: 1. THESE DRAWINGS ARE SCHEMATIC IN NATURE AND ARE NOT INTENDED TO SHOW ALL POSSIBLE CONDITIONS. IT IS INTENDED THAT A COMPLETE HVAC SYSTEM BE PROVIDED WITH ALL NECESSARY EQUIPMENT, APPURTENANCES AND CONTROLS COMPLETELY COORDINATED WITH ALL DISCIPLINES. ALL MECHANICAL EQUIPMENT AND INSTALLATIONS SHALL CONFORM WITH THE REQUIREMENTS OF ALL STATE BUILDING CODES, THE NFPA 90A, 101 AND ALL LOCAL AUTHORITIES AND THESE CONTRACT DOCUMENTS. THESE ITEMS SHALL BE FURNISHED WITHOUT INCURRING ANY ADDITIONAL COST TO THE OWNER. THE WORD "PROVIDE" SHALL MEAN FURNISH AND INSTALL. CAREFULLY REVIEW ALL CONTRACT DOCUMENTS AND THE DESIGN OF OTHER TRADES BEFORE PREPARING SHOP DRAWINGS. 2. PRIOR TO PURCHASING ANY MATERIALS OR STARTING ANY WORK, CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS, DUCTWORK SIZES AND LOCATIONS, EQUIPMENT, ETC. SHOWN ON THE DRAWINGS OR AFFECTING THIS WORK AND SHALL REPORT ANY DEVIATIONS TO THE ARCHITECT. 3. CONTRACTOR SHALL COORDINATE ELECTRICAL CHARACTERISTICS AND REQUIREMENTS OF ALL MECHANICAL EQUIPMENT WITH ELECTRICAL DRAWINGS PRIOR TO ORDERING EQUIPMENT OR SUBMITTING SHOP DRAWINGS, AND SHALL FURNISH EQUIPMENT WIRED FOR THE VOLTAGES SHOWN THEREIN. 4. ALL MECHANICAL EQUIPMENT REQUIRING ELECTRICAL POWER SHALL BE INSTALLED WITH DISCONNECT SWITCHES AT EACH PIECE OF EQUIPMENT. COORDINATE SWITCH TYPE (FUSED OR NON -FUSED) WITH EQUIPMENT CHARACTERISTICS, MANUFACTURER'S RECOMMENDATIONS AND ELECTRICAL DRAWINGS. 5. ALL REQUIRED CONTROL WIRING NOT SHOWN ON THE ELECTRICAL DRAWINGS SHALL BE INCLUDED AS PART OF THE MECHANICAL WORK. 6. UNLESS NOTED OTHERWISE, STARTERS, SMOKE DETECTORS, TRANSFORMERS, CONTROLS AND CONTROL WIRING REQUIRED FOR ALL MECHANICAL SYSTEMS SHALL BE FURNISHED AND INSTALLED BY THE MECHANICAL CONTRACTOR. 7. ALL FANS SUPPLYING MORE THAN 2000 CFM OF AIR TO ANY SPACE AND ALL RECIRCULATING FAN SYSTEMS SERVING AREAS OF EGRESS SHALL BE INSTALLED WITH A SMOKE DETECTOR IN THE SUPPLY DUCTWORK. THE SMOKE DETECTOR SHALL BE WIRED TO STOP THE FAN UPON DETECTION OF SMOKE, AND SIGNAL THE BUILDING FIRE ALARM CONTROL PANEL (IF BUILDING IS SO EQUIPPED). IF THE BUILDING IS NOT PROVIDED WITH A FIRE ALARM SYSTEM, THE SMOKE DETECTOR SHALL CAUSE A VISIBLE AND AUDIBLE ALARM SIGNAL IN A NORMALLY OCCUPIED AREA. SMOKE DETECTOR TROUBLE CONDITIONS SHALL BE INDICATED VISUALLY OR AUDIBLY IN A NORMALLY OCCUPIED AREA AND SHALL BE IDENTIFIED AS AIR DUCT DETECTOR TROUBLE. IF A BUILDING FIRE ALARM SYSTEM IS INSTALLED, THE SMOKE DETECTOR SHALL BE FURNISHED BY THE FIRE ALARM SYSTEM CONTRACTOR, MOUNTED IN THE DUCT BY THE MECHANICAL CONTRACTOR, AND WIRED BY THE ELECTRICAL CONTRACTOR. IF A BUILDING FIRE ALARM SYSTEM IS NOT INSTALLED, THE SMOKE DETECTOR AND AUDIBLE/VISIBLE ALARM SHALL BE FURNISHED AND INSTALLED BY THE MECHANICAL CONTRACTOR. 8. INSTALL FIRE DAMPERS IN ALL RATED THROUGH WALLS, FLOOR AND CEILING PENETRATIONS. REFER TO THE ARCHITECTURAL DRAWINGS FOR LOCATIONS OR RATED AREAS. PROVIDE ACCESS DOORS IN DUCTWORK AT EACH FIRE DAMPER LOCATION. INSTALL SMOKE DAMPERS IN ALL DUCT PENETRATIONS THROUGH SMOKE RATED WALLS. WHERE DUCTS PENETRATE WALLS THAT CARRY BOTH FIRE AND SMOKE RATINGS, THE DAMPERS INSTALLED SHALL BE COMBINATION FIRE AND SMOKE DAMPERS. ALL DAMPERS SHALL BE U.L. LABELED. 9. ALL MECHANICAL EQUIPMENT SHALL BE INSTALLED ACCORDING TO MANUFACTURER'S RECOMMENDATIONS. 10. ALL MECHANICAL EQUIPMENT AND SYSTEMS SHALL BE GUARANTEED FOR A PERIOD OF ONE YEAR AFTER CERTIFICATE OF OCCUPANCY. 11. EXHAUST DUCTWORK SHALL BE SHEET METAL AND SHALL NOT BE INSULATED UNLESS NOTED OTHERWISE. 12. ALL DUCTWORK SHALL BE SUPPORTED BY THE BUILDING STRUCTURE AND SHALL NOT REST ON CEILING TILES OR CEILING STRUCTURE. DUCT SUPPORTS AND ATTACHMENT TO STRUCTURE SHALL BE AS PER SMACNA STANDARDS. 13. FLEXIBLE DUCTWORK SHALL BE SIZED TO MATCH DEVICE NECK, PROVIDE ROUND GALVANIZED STEEL DUCT RUNOUTS TO MAINTAIN MAXIMUM FLEXIBLE DUCT OF 5'-0" LONG. FLEXIBLE DUCTWORK SHALL BE INSTALLED AS STRAIGHT AS POSSIBLE, AND SHALL BE ROUTED AND SUPPORTED WITHOUT FORMING CRIMPS OR OTHER AIR FLOW RESTRICTIONS. PROVIDE SQUARE TO ROUND ADAPTERS OR BOOTS TO CONNECT TO AIR DEVICE NECK WHEN REQUIRED. 14. ROUND AND FLEXIBLE DUCTWORK SHALL BE CONNECTED TO MAIN DUCTS WITH SPIN -IN FITTINGS WITH AIR EXTRACTORS AND BALANCING DAMPERS. 15. PORTIONS OF DUCTWORK VISIBLE THROUGH AIR DISTRIBUTION DEVICES IN FINISHED AREAS SHALL BE PAINTED FLAT BLACK. 16. DUCTWORK DIMENSIONS SHOWN ON THE DRAWINGS ARE INSIDE CLEAR DIMENSIONS. CONTRACTOR SHALL ADJUST DUCT DIMENSIONS WHERE DUCT LINER IS USED M MAINTAIN INSIDE CLEAR DIMENSIONS SHOWN ON DRAWINGS. 17. THE CONDENSATE SHALL DRAIN TO A SANITARY SEWER DRAIN TROUGH AN INDIRECT WASTE, STORM SEWER DRAIN OR AN APPROVED FRENCH DRAIN. THE APPROVED CORROSION -RESISTANT DISCHARGE PIPING SHALL NOT BE SMALLER THAN THE DRAIN PAN CONNECTION ON THE APPROVED EQUIPMENT AND SHALL MAINTAIN A MINIMUM HORIZONTAL SLOPE IN THE DIRECTION OF DISCHARGE OF NOT LESS THAN 1/8 UNIT VERTICAL IN 12 UNITS HORIZONTAL (17.). 18. AFTER CONSTRUCTION, THE ENTIRE HVAC SYSTEM SHALL BE TESTED, ADJUSTED, AND BALANCED TO DELIVER THE AIR QUANTITIES SHOWN ON THE DRAWINGS. SUBMIT CERTIFIED TEST AND BALANCE REPORT TO ARCHITECT FOR APPROVAL. 19. MANUAL OVER -RIDE CONTROL (EMERGENCY SHUT -DOWN) SWITCHES FOR ALL HVAC UNITS SHALL BE LOCATED IN LOCKING COVER ADJACENT TO FIRE ALARM ANNUNCIATOR PANEL OR OTHER LOCATION APPROVED BY LOCAL AUTHORITY HAVING JURISDICTION. 20. ALL WORK SHALL BE COORDINATED AND PERFORMED WITH PRIOR APPROVAL FROM THE OWNER TO SUIT HIS OPERATING CONDITIONS. 21. ANY WALL, FLOOR, OR CEILING SURFACE THAT IS DISTURBED DURING THE COURSE OF THE HVAC WORK SHALL BE REPAIRED TO MATCH NEW AND/OR EXISTING. 22. CONTRACTOR SHALL COORDINATE THE INSTALLATION OF ALL MECHANICAL EQUIPMENT, DUCTWORK, ETC. TO FIT WITHIN THE SPACE ALLOWED BY THE ARCHITECTURAL AND STRUCTURAL CONDITIONS. CUTTING OR OTHERWISE ALTERING ANY STRUCTURAL MEMBERS SHALL NOT BE PERMITTED WITHOUT WRITTEN PERMISSION FROM THE ARCHITECT. 23. MOUNT THERMOSTATS 48" AFF UNLESS NOTED OTHERWISE. PROVIDE CLEAR LOCKING COVER ASSEMBLIES FOR ALL THERMOSTATS. 24. LOCATIONS OF GRILLES, REGISTERS, & DIFFUSERS SHOWN ON THE DRAWINGS ARE APPROXIMATE. COORDINATE EXACT LOCATIONS WITH LIGHTS, CEILING GRID, SPRINKLER HEADS ETC. 25. SLOPE ALL HORIZONTAL GAS FLUE PIPING MINIMUM 1/4" PER FOOT. 26. GAS FLUE PIPING SHALL BE TYPE "B" DOUBLE WALL FLUE, U.L. LISTED, EXCEPT FOR INDUCED OR FORCED DRAFT EQUIPMENT, WHICH SHALL BE TYPE PS, METALBESTOS OR EQUAL. 27. TERMINATE ALL GAS FLUE PIPING THRU ROOF WITH TALL CONE FLASHING, STORM COLLAR, AND WEATHER CAP. 28. PROVIDE ACCESS PANELS IN NON -ACCESSIBLE CEILINGS AND IN WALL STRUCTURE TO ALLOW ADEQUATE ROOM FOR MAINTENANCE OF EQUIPMENT AND BALANCING OF SYSTEM. Greenberghrrow 1430 West Peachtree Street Atlanta, GA 30309 t: 404 6014000 f. 404 (601 3980 COPYRIGHT NOTICE This drawing is the property of the above referenced Professional and is not to be used for any purpose other than the specific project and site named herein, and cannot be reproduced in any manner without the express written permission from the Professional ISSUE/REVISION RECORD DATE DESCRIPTION 12/5/07 ISSUED FOR PERMIT T i%rv, c-oA 4- t6007== PROFESSIONAL SEAL PROFESSIONAL IN CHARGE JUSTIN HARDY, P.E. 67084 PROJECT MANAGER STEVE ALLEN QUALITY CONTROL AMY HADLOW P.E. DRAWN BY STEVE ALLEN PROJECT NAME NAPA AUTO PARTS ZEPHYRHILLS FLORIDA 6901 GALL BOULEVARD 41APA r- PROJECT NUMBER 20070208 SHEET TITLE MECHANICAL DETAILS AND SCHEDULES SHEET NUMBER M2mO `' AtA