HomeMy WebLinkAbout6951 Gall Blvd (2)0.
A
is' all
REVISED FLOOR PLAN 1/4" 11011
EXISTING ROOF
0
1/2" 2' X 4' DROP IN CEILING TILE
AND METAL GRID SYSTEM.
3 5/5" 25 GA, METAL STUDS WITH 1/2" GYPSUM WALL
BOARD EACH SIDE, SECURE STUD WALL AT BOTTOM
0 THROUGH STEEL TRACK WITH MASONRY ANCHORS
THAT PENETRATE CONCRETE MINIMUM I" SPACED
24" CC, AND AT TOP WITH ZIP PEAL STRIP SCREWED
TO METAL CEILING TILE GRID SYSTEM
0
101
TYPICAL INTERIOR METAL STUD WALL DETAIL
REVISED BUILDING DATA:
OCCUPANCY
CLASSIFICATION: BUSINESS GROUP B ( NO CHANGE
CONSTRUCTION TYPE: Ill
FIRE PROTECTION: NON SPRINKLED
OCCUPANCY CAPACITY: 1505 5Q, FT, / 100 - lro PEOPLE
PLUMBING FIXTURE REQUIREMENTS PER TABLE 403.1
WATER CLOSET: I RESTROOM PER 25 FOR THE FIRST
50 PEOPLE
LAVATORY.- I PER 40 FOR THE FIRST 80 PEOPLE
NOT TO SCALE
A5 5UILT f=LOOR PLAN 1/4 11011
SUBMITTED PLAN(S) HAVE BE&N REV WBO,
2y ZEPEPffYRHILLS FIRE
Date:
wer
Please be advised this review of plans submitted is a
Cursory review to assist the contractor in compliance with
applicable fire safety codes. This review is not intended
o to be a final approval of the submitted plans, it is the
o contractor's sole responsibility to ensure that the plans are in
complete cOmPli, ace with all applicable NFPA codes and
local ordinances, ;;I the event that further examination or
site inspection rev.als areas of non-cornpliance, it shall be
the contractor's sore responsibility, at hWr sole expense to
bring those areas in compliance, ThO City assumes no
responsibility for the contractor's failure to be in compliance
with all applicable NFPA Codes and local ordinances.
33
ko /1"
4REVIEW DATE
CITY 14 11 1 �q
OF ZEPHYRHILLS
6A_fj4WfLANS EXAMINER��
ALL WORK SHALL COMPLY WITH ALL
PREVAILING CODES, FLORIDA BUILDING
CODE, NATIONAL ELECTRIC CODE AND
CITY OF zEHyRIHLLS ORDINANCES
AS BUILT BUILDING DATA:
OCCUPANCY
CLASSIFICATION: BUSINESS GROUP 5
CONSTRUCTION TYPE: Ill
FIRE PROTECTION: NON SPRINKLED
OCCUPANCY CAPACITY: 1515 50, FT, 100 = 1& PEOPLE
PLUMBING FIXTURE REQUIREMENTS PER TABLE 403,1
WATER CLOSET: I RESTROOM PER 25 FOR THE FIRST
50 PEOPLE
11
ELECTRICAL LEGEND
SERVICE LIGHT
PANEL
exit LIGHT SWITCH
EXIT SIGN
ExR 220 OUTLET
EMERGENCY LIGHT
EXIT SIGN COMBO
110 OUTLET
Q=D GFi
EMERGENCY LIGHTING 110 GFI OUTLET
BATH EXHAUST FAN
PP7
DOUBLE 40LUATT
DOUBLE 40WATT FLUORESCENT
FLUORESCENT HARD WIRE NITE LIGHT
ELECTRICAL WORK TO BE PREFORMED ON SITE
MUST BE DONE BY LICENSED CONTRACTOR IN
THERE RESPECTED FIELD. THEY WILL BE
RESPONSIBLE FOR VERIFYING ALL WORK MEETS
LOCAL AND STATE OF FLORIDA BUILDING CODES
REVISED LIGHTING 4 CEILING PLAN 1/4" _ Poll
RELOCATED EXISTING LIGHTS AS SHOWN
~~w