Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
7331 Gall Blvd (2)
INTERIOR • / 7 REVIEW DATEFOR • CITY OF ZEPHY ILLS FIRE AND LIFE SAFETY EXAMINER_ ALL WORK SHALL COMPLY WITH NFFA CODES AND STANDARDS /331 GALL BOULt ARD REVIEW DATE: ZEP11YFJULS, nOFMA 33541 - CITY OF ZEPHYRHILLS BUILDING OFFICIAL ALL WORK SHALL COMPLY WITH PREVAILING CODES FLORIDA BUILDING CODE, NATIONAL ELECTRIC CODE, AND THE CITY OF ZEPHYRHILLS ORDINANCES GENERAL NOTE5 PROJECT TEAM DRAWING INDEX BUILDING CODE INFORMATION BUILDING CODE INFORMATION CCONT.) A. ALL WORK SHALL CONFORM TO THE LATEST ADOPTED EDITION Of THE NATIONAL FIRE CODE 'FLORDA BUILDING GOD[.* 'FLORIDA PLUMBNG GODS.' TLORIDA MECHANICAL CODE.' 'NATIONAL ELECTRICAL CODE.' AND ALL OTHER APPLICABLE LOCAL. STATE. AND FEDERAL CODES AND ORDINANCES. AND ALL AUTHORITIES HAVING LOCAL JURISDICTION. B. THE GENERAL CONTRACTOR SHALL PERFORM ALL WORK N AGGORDANGE WITH THE CURRENT EDITION OF THE 'GENERAL CONDITIONS Of THE CONTRACT FOR CONSTRUGTION' AlA DOCUMENT A201. ARCiI'IITEGT PAVALIS ARGHII7EKTON 417 SOUTH PINELLAS AVENUE TARPON SPRINGS. FLORIDA 34G89 andrew•pavab.com ELEGTRIGAL GULF COAST ELECTRICAL DESIGN 2111 SUNNYDALE BLVD. SUITE D GLEARWATER. FLORIDA 33765 727-330-4937 N � un N w �r a o o '- o > O w O o 0 N 0 > O w O o 0 n 0 > O w O O o Nt 0 a � a o GENERAL PRf i,iEGT INFORMATION PROJECT NAME: BREAKFAST STATION PROJECT ADDRESS: 7331 GALL BLVD,, ZEPHYRHILLS, FLORIDA PROPOSED USE: RESTUARANT a CODE ENFORCEMENT JURISDICTION: CITY OF ZEPHYRHILLS OCCUPANT LOAD FBC - BUILDING, CHAPTER 10 (TABLE 1004.1,2) WAITING 70 SF 15 GROSS 5 PERSONS DINING 1,468 SF # OF SEATS 85 PERSONS KITCHEN 1,540 SF 200 GROSS 8 PERSONS TOILETS --- 1 PER TOILET 3 PERSONS SHEET # SHEET TITLE Architect ra T101 Title Sheet & Code Information • LS101 Life Safety Plan • APPLICABLE BUILDING GLIDES FLORIDA BUILDING CODE, 7TH EDITION......................................................2020 FLORIDAACCESSIBILITY CODE, 7TH EDITION ...........................................2020 FLORIDA PLUMBING CODE, 7TH EDITION..................................................2020 FLORIDA MECHANICAL CODE, 7TH EDITION..............................2020 FLORIDA EXISTING BUILDING CODE, 7TH EDITI❑N....................................2020 FLORIDA FIRE PREVENTION CODE, 7TH EDITION...................................2020 NFPA 70, NATIONAL ELECTRICAL CODE................................................I......2017 G. THE CONTRACTOR SHALL. UPON DISCOVERY. GIVE WRITTEN NOTICE TO THE ARCHITECT OF ANY MATERIALS. EQUIPMENT. OR DESIGN FEATURES WHICH HE BELIEVES TO BE INADEQUATE OR UN5UITABLE. N VIOLATION Of LAWS. ORDINANCES. OR RULES AND REGULATIONS OF THE AUTHORITIES HAVING JURISDICTION OVER THE WORK, AND OF ANY NECESSARY ITEMS OR WORK OMITTED FROM THE DRAWINGS. D. ALL 5UBGONTRAGTOR5 SHALL USE ONLY SKILLED GRAFT5MEK EXPERIENCED IN THE WORK OF THEIR TRADE, TO ENSURE FIRST GLASS WORKMANSHIP. ANY WORK NOT EQUAL TO BEST TRADE STANDARDS SHALL BE REMOVED AND REPLACED AT NO ADDITIONAL COST. SHOULD ANY 5UBGONTRAGTOR REFUSE TO REMOVE AND REPLACE UN505FAGTORY WORK. THE CONTRACTOR MAY REMOVE AND REPLACE IT. AND CHARGE THE G05T TO THE SUBCONTRACTOR. MECHANICAL STEPANEK LEWI5 + ASSOCIATES 2257 TWELVE OAKS WAY WESLEY CHAPEL, FLORIDA 33544 813-991-1248 PLUMBING STEPANEK LEWI5 + ASSOCIATES 2257 TWELVE OAKS WAY WESLEY CHAPEL. FLORIDA 33544 813-991-1248 TOTAL: 101 PERSONS EXIT EGRE55 EGRESS WIDTH PER OCCUPANT - TABLE 1005.3.2 101 x 0.2 = 20.2" ALLOW, PROVIDED MIN. CLEAR DOOR OPENING - 1010.1.1 32' 2 32' AD101 Demo Floor Plan • A101 Proposed Floor Plan • A601 Reflected Ceiling Plan • A801 Furniture Floor Finish Plan • FS101 Food Service Equipment • P001 Plumbing Specifications • E. IT 15 THE GENERAL GONTRAGTOR'5 SOLE RE5PONSIBILITY TO DETERMINE EREGTION PROCEDURE AND SEQUENCE TO ENSURE THE SAFETY OF PEOPLE AND OF THE BUILDING AND ITS COMPONENT PARTS DURING GON5TRUGTION. THI5 NGLUDE5. BUT 15 NOT LIMITED TO. THE ADDITION OF WHATEVER TEMPORARY BRACING OR TIE DOWNS THAT MAY BE NEGE55ARY. 5UGH MATERIAL SHALL BE REMOVED AND SHALL REMAIN THE PROPERTY OF THE CONTRACTOR AFTER COMPLETION OF THE PROJECT. (EXCEPT ARTICLE 80) MIN, CLEAR STAIR WIDTH - 1011.2 N/A N/A COMMON PATH OF TRAVEL - 1006.2.1 75 FT <75 FT EXIT ACCESS TRAVEL DIST, - TABLE 1017,2 250 FT <250 FT MIN. CORRIDOR WIDTH - 1020.2 36' > 36' DEAD END CORRIDOR - 1020.4 20 FT NONE MIN, NUMBER OF EXITS - 1006.3.1 2 4 P002 Plumbing Schedules & Details • P100 Demo Floor Plan • OGGUPANGY CLA551FIGATION m EX15TING FBC - BUILDING, CHAPTER 3 • SECTION 304: ASSEMBLY OCCUPANCY - GROUP (A-2) (SPRINKLERED) P1 01 Plumbing Floor Plan • M001 Mechanical Specifications • M002 Mechanical Schedules • F. ALL PRODUCTS AND PARTS SHALL FIT TOGETHER NEATLY, WITHOUT DAMAGE OR DISFIGUREMENT. EXIECPT FOR NUMBER AND SIZE OF EXITS REQUIRED PROVIDED SPECIFIED CURVED SURFACES, ALL PRODUCTS AND PARTS SHALL BE CONSTRUCTED/ FABRICATED AND INSTALLED TRUE. N LINE. AND PLUMB. ALL NON CONFORMING WORK SHALL BE REJEGTED AND RE-AGGOMPL15HED BY THE GENERAL CONTRACTOR AT NO ADDITIONAL COSTS TO THE OWNER. G.ALL WORK SHOWN ON THE DRAWINGS SHALL BE CONSTRUCTED Of NEW COMPONENTS. MIN, NUMBER OF EXITS 2 4 SINGLE ENTRANCE/EXIT DOOR 34 X 3 = 102' DOUBLE ENTRANCE/EXIT DOOR 68 X 1 = 68' TACTILE SIGNAGE M003 Mechanical Details • GLA551FlGATION OF WORK FEBC - EXISTING BUILDING, SECTION 502 • ALTERATION LEVEL 3 MD04 Mechanical Details Kitchen Exhaust • M005 Mechanical Details Kitchen Exhaust • M006 Mechanical Details Kitchen Exhaust • M 100 Demo Floor Plan • H. ALL PRICING SHALL BE PREPARED FROM A COMPLETE SET OF CONSTRUCTION DOCUMENTS. COMPLETE SETS Of DOCUMENTS SHALL NOT BE BROKEN UP FOR BID PURPOSES, SUCH ACTION MAY RESULT IN A LACK OF INFORMATION N REFERENCE TO THE SCOPE OF WORK TO BE PERFORMED. I IT SHALL BE THE GENERAL GONTRAGTOR'5 RESPONSIBILITY TO PER50NALLY FIELD INSPECT THE PROJECT 51TE PRIOR TO THE PREPARATION AND SUBMITTAL Of HI5 BID. THIS INSPECTION 15 REQUIRED 50 THAT THE GONTRACTOR SHALL BE TOTALLY FAMILIAR WITH THE EXISTING CONDITIONS AND THEIR INTERFACE WITH THE NEW CONSTRUCTION AS DEFINED N THESE CONSTRUCTION DOCUMENT5. TACTILE SIGNAGE SHALL BE PROVIDED PER LSC101 CH 7,10,13. TACTILE SIGNAGE SHALL BE LOCATED AT EACH EXIT DOOR REQUIRING AN EXIT SIGN. TACTILE SIGNAGE SHALL READ AS FOLLOWS: EXIT TACTILE SIGNAGE SHALL COMPLY WITH ICC/ANSI A117.1 GON5TRUCTION NOTE5 M101 Mechanical Ceiling Plan • G05TRUGTION TYPE 6 EXISTING BUILDING TYPE V-B EO.0 Symbols Legend, Details, Notes & Abbrev. • 1. INTERIOR FINISH MATERIALS APPLIED TO WALL AND CEILING SHALL BE IN ACCORDANCE WITH A5TM E84. E1.0 Power Plan • PROJECT 5COPE E2.0 Lighting Plan • E3.0 Power Riser Diagram & Panel Schedule • 2. ALL EXIT DOORS SHALL BE OPERABLE FROM THE EGRESS SIDE WITHOUT THE USE OF A KEY, TOOL. J. UNLESS OTHERWISE SPECIFIED, THE G.G. SHALL FURNISH A WRITTEN GUARANTEE FOR ALL WORK (EQUIPMENT. MATERIALS. AND LABOR). AGAINST ANY DEFECTS IN SAID WORK FOR A PERIOD OF ONE (1) YEAR FROM THE DATE OF SUBSTANTIAL COMPLETION. WITH ALL APPROPRIATE REPAIRS OR REPLACEMENTS AT NO ADDITIONAL G05T TO THE OWNER. SPECIAL KNOWLEDGE OR EFFORT. MANUALLY OPERATED FLUSH BOLTS OR SURFACE BOLTS SHALL NOT BE USED. 3. ALL GLAZING WITHIN A 24 INCH ARC OF DOORS WH05E BOTTOM EDGE 15 LE55 THAN GO INCHES ABOVE THE FLOOR AND GLA55 BELOW 18' A.F.F. AND ALL GLAZING N DOORS SHALL BE SAFETY GLASS. MINIMUM PLUMBING FACILITES (FPC CHAPTER 4) ASSEMBLY, 101 PERSONS - PER FLOOR (TABLE 403.1) PLUMBING FIXTURE REQUIRED PROPOSED E4.0 Cut Sheets • RESTAURANT INTERIOR RENOVATION OF APPROX. 3.142 SF ON GROUND FLOOR OF EXISTING 1-STORY BUILDING. 5GOPE OF WORK TO INGLUDE FULL ARCHITECTURAL. MINOR ELECTRICAL. MECHANICAL AND PLUMBING WORK. K. IT SHALL BE THE RESPONSIBILITY Of THE G.G. AND/OR CONTRACTORS TO COMPLY WITH ALL THE REQUIREMENTS Of THE OCCUPATIONAL SAFETY AND HEALTH ACT OF 197D BY THE U.5. DEPARTMENT Of LABOR. AND REQUIRE ALL ITS 5UBGONTRAGTOR5 AND EMPLOYEES TO COMPLY WITH THI5 LAW. AND ANY RELATED STATE OR LOCAL LAWS. TEMPERED GLA55 OR ACRYLIC PLASTIC SHEET. PER 550C 2405.2.1 4. OBJECTS PROTRUDING FROM WALLS WITH THEIR LEADING EDGES BETWEEN 27' AND 80' ABOVE THE FINISHED FLOOR SHALL PROTRUDE NO MORE THAN 4' INTO WALKS. HALLS. GORRIDOR5. PASSAGEWAYS. OR AISLES. OBJECTS MOUNTED AT OR BELOW 27' ABOVE FINISHED FLOOR MAY NOT PROTRUDE ANY WATER CLOSETS 2 3 LAVATORIES 1 3 DRINKING FOUNTAINS 0 O(SERVES WATER) SERVICE SINK 1 1 AERIAL MAP L. THE DATA GIVEN HEREIN AND ON THE DRAWINGS 15 AS EXACT AS GOULD BE 5EGURED. THEIR ABSOLUTE ACCURAGY AMOUNT. FREE STANDING OBJECTS MOUNTED ON P05T OR PYLONS MAY OVERHANG 12'. PROTRUDING 15 NOT GUARANTEED. AND THE G.G. SMALL OBTAIN EXACT LOCATIONS. MEASUREMENTS. LEVELS. ETC. AT THE SITE AND SHALL SATISFACTORILY ADAPT HI5 WORK TO THE AGTUAL CONDITIONS Of THE BUILDNG. DO NOT OBJEGT5 SHALL NOT REDUCE THE CLEAR WIDTH OF AN AGGE59BLE ROUTE OR MANEUVERING SPACE. INTERIOR FINI5HE51 SCALE PRINT5. VERIFY ALL DIMEN51ONS WITH THE ARCHITECT PRIOR TO COMMENCING WORK. 5. PROVIDE DEADWOOD BLOCKING WITHIN WALL CAVITIES AT LOCATIONS INCLUDING, BUT NOT LIMITED TO. WALL MOUNTED GABNETRY. FIRE EXTINGUISHER CABINETS. TOILET ACCESSORIES, GRAB BARS. FBC, - BUILDING. CHAPTER 8 BUSINESS - GROUP A-2 (5PRINKLERED) M. THESE DOCUMENTS AND THE INFORMATION CONTAINED HERFL1 5HALL NOT BE ALTERED IN ANYWAY BY THE CONTRACTOR OR THE OWNER. ALTERATIONS SHALL BE MADE ONLY BY THE ARCHITECT OF RECORD. N. THE CONTRACTOR SHALL INSPECT THE 51TE AND BUILDING, PRIOR TO SUBMITTING HIS BID, AND SHALL BRING TO THE WALL STOPS. ETC.. 18GA. GALV. FLAT METAL MAY BE USED N LOCATIONS APPROVED BY ARCHITECT. G. ALL RATED PARTITIONS SHALL EXTEND FROM THE TOP OF THE FLOOR TO THE GEILNG AND BE SECURELY ATTACHED THERETO. WHERE SAID CEILING 15 NOT PART OF AN A55EM13LY HAVING A FIRE RESISTANCE INTERIOR WALL AND CEILING FIN15H REQUIREMENTS - TABLE 803.11 VERTICAL EXITS AND EXIT PA55AGEWAY5, GLASS B EXIT ACCESS CORRIDORS / EXITWAYS, GLA55 B ROOMS AND ENCLOSED SPACES, GLASS G ARGHffEGT'5 ATTENTION ANY EXISTING CONDITION WHICH MAY VARY FROM WHAT 15 SHOWN IN THESE DOGUMENT5. RATING AT LEAST EQUAL 10 THAT REQUIRED FOR THE PARTITION, THE PARTITION SHALL BE CONSTRUCTED TIGHT AGAINST THE FLOOR OR THE ROOF DECK ABOVE. INTERIOR WALL AND CEILING FINISHES SHALL BE CLASSIFIED IN ACCORDANCE WITH ASTM E 84. ,LN 7. PENETRATION OF FIRE RATED WALL A55EMBLE5 FOR ELEGTRIGAL. SUSPENDED ACOUSTICAL CEILING SYSTEMS SMALL BE INSTALLED IN ACCORDANCE TELEPHONE. PLUMBING. H.VA.G. DUGT5. COMMUNICATION SYSTEMS OR 51MILAR fAGILITE5 5HALL BE WITH THE PROVISIONS OF ASTM G CD35 AND ASTM G G3G. PERMITTED BY NON-GOM13U5TIBLE PRE OR CONDUIT WHEN ALL OPENINGS AROUND THE PRE OR CONDUIT ARE FIRE5TOPPED WITH APPROVED NON-GOMBU5TIBLE MATERIALS OR WHEN THE PENETRATION 15 PROTECTED WITH A SYSTEM WHICH HAS AN T' RATING EQUAL TO OR GREATER THAN THE A55EMBLY IN WHICH THE PENETRATION OCCURS. MATERIAL. OTHER THAN FOAM PLASTIC USED AS INTERIOR TRIM SHALL HAVE A MINIMUM CLA55 G FLAME SPREAD AND SMOKE -DEVELOPED INDEX WHEN TESTED IN ACCORDANCE WITH A5TM E 84. µ^'"°^.itoo16 O AGGE551BILITY NOTE 8.WALL A55EMBLIES NOTED AS U.L.. GA. OR OTHER APPROVED TESTING AGENCIES ARE CON51DERED PROPRIETARY. PROPRIETARY ASSEMBLIES MUST BE BUILT UTILIZING THE COMPONENTS, MEANS, AND METHODS SPECIFIED BY THE TESTING AGENCY. 9. PROVIDE AND INSTALL PORTABLE FIRE EXTNGL15HERS AS SHOWN N THESE DOCUMENTS PROJECT " ' "'� PER CHAPTER 2 OF THE FBC-A THE FOLLOWING IMPROVEMENTS FOR ADA OR AS OTHERWISE DIRECTED BY THE LOCAL FIRE MARSHAL. AGGES5I13ILITY ARE PART OF THI5 PROJECT SCOPE OF WORK: 10.9GNAGE SHALL BE PROVIDED AS REQUIRED AND AS STATED N THE 202D FLORIDA ACCESSIBILITY GODS FOR BUILDING GON5TRUGTION AND SHALL COMPLY WITH CHAPTER 7 SECTION 703 SIGNS. 1. EXISTING EXITS HAVE BEEN VERIFIED TO MEET ADA REQUIREMENTS 3. PROVIDE (3)ADA TOILET ROOMS w1l , '+P® © a U !1 O� (1 `) LULU I..L ll N C] c) a - co c9 ONE" �. �E �a a LLl. Q LLc0 � Ln A . d o a 39 t q) LO ��_ ` Q l0 L ' 6 E m � IL - 7F a�T- U Z r-+ O O 0 Q �--- Q Z < > 6 6,1I_ J. z Ll < � Q 0 . co J CL OIL` W E N H t~ ti,�al •> OF F1,o Z. pq�4;4 CO, y� N9 AR96063 A. �,n��3��r .ssitm:fttt Datc: 1. 25. 22 Ch,, Lrd LN: AZP 14awii: N1_A11 'I'd): -' I -0 1:' ti 1„ � i T101 I i170l[34' 170 34- LIFE 5AFETY PLAN 5CALEI 1/4' - 1.—O' L !, J LI 1 I __ 1 I ATTIC O ACCESS ® 105 \ 104 TRAVEL D15TANGE = 45"-3- KITCHEN 10G 91 / / DISH WASHNG 109 108 1, N T_ 110 SERVNG /GASOM 103 ! 1 I I III J I __. _ fill I I 1 '1' 1' I'll _ I I I 1_ _ It, I _ —_ _.11 L' If I . _ 1 11 ■ 1 _ ' IPI "I ,"I ' III _P; _ I I _ TRAVEL 015TANCE = 50'-1' TRAVEL D15TANGE = G7'—B' n HALL 112 EXISTING r� BUSS STATII T= 111 n DMG 101 E 4' 170 1 __ t _ I. 1 11 1 1 11111 _L_ I I I I I I I 1-11 11-1 11 1011111m 5YMBOL LEGEND r F- WALL MOUNTED FIRE EXTINGUISHER ® EXIT SIGN EXIT OAPAGITY CAPACITY OF EXIT �: XXX X CLEAR WIDTH TRAVEL DISTANGE TRAVEL DISTANCE CTD) fl)IRECTION OF TRAVEL ALL EMERGENCY LIGHTS ARE EXISTING TO REMAIN. �iuuu co �9 r� z pC Vj O a ~ L � � - Lj > `i'£ .1u Kb fir/ 1 J .11 O p Z aL Q t� W Q Q D O Z IS 0 o— °� Q Q L_ LL_ ire W Q Mw,�r_ 40 I.�IL W W L— � N ��J q W � Date: 4. 25. 22 Checked by: AZP Drawn: MAU Job: 21-042 Sheet LS1 01 J jul_ . :.. _ .2 i I i I _ 1 :Ili. . t _ _ I , i i — 11 :I __i __ :. LI_1_.ILI-II I lw:e-IWIF1:IM—MM-111` L, 11_1 L I I , IIV V Li 1 r I_ i I i I I I III 1 11 "1 _ i 11__ If"11L�'1 1 i DEMO FLOOR PLAN SCALE, 1/4' = 1'-0' DEMO — KEYED NOTES lO EXISTING COLUMN - TO REMAIN 2O EXISTING ELECTRICAL PANEL/EQUIPMENT (D EXISTING DOOR TO BE REMOVED - SALVAGE FOR RE-U5E. O4 EX15TING WALL TO BE DEMOLISHED. OREMOVE PORTION OF EXISTING 1-HOUR RATED WALL FROM FLOOR TO +S'-O' A.F.F. OEXISTING PLUMBING FIXTURE TO BE REMOVE - PIPES TO BE CAPPED. 7O EXISTING MILLWORK TO BE DEMOLISHED. O8 EXISTING KITCHEN EQUIPMENT TO BE DEMOLISHED. OEXISTING STAINLESS STEEL SERVING SHELF/COUNTER. 10 EXISTING WINDOW TO BE DEMOLISHED - OPENING TO BE INFILLED. EX15TING/DEMOLITION WALL LEGEND JEXISTING DOOR SYSTEM EXISTING WINDOW SYSTEM EXISTING WALL PARTITION T II �� \ =J l� 6 = EX15TING DOOR SYSTEM TO BE REMOVED EXISTING WALL PARTITION TO TO BE REMOVED rF-- = = Eg) EXISTING WINDOW SYSTEM TO BE REMOVED DEMOLITION GENERAL NOTE 5 1. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR THE SAFE AND LAWFUL DISPOSAL OF ALL MATERIALS DEMOLISHED. HOWEVER, THE OWNER SHALL BE GIVEN THE OPPORTUNITY TO SALVAGE ANY EQUIPMENT. FIXTURES OR MATERIAL. 2. ALL EXISTING CONSTRUCTION TO REMAIN, SHALL BE PATCHED AND REPAIRED AT AREAS WHERE DEMOLITION WORK HA5 OCCURRED TO A CONDITION THAT MATCHES THE EXISTING ADJACENT CONSTRUCTION. EXISTING WALLS THAT CONTAIN PLUMBING. ELECTRICAL OR OTHER SERVICES REQUIRING MODIFICATION SHALL BE CUT BACK TO THE NEAREST STUD TO ALLOW REQUIRED WORK. AFTER COMPLETION. RECONSTRUCT TO A CONDITION THAT MATCHES NEW CONSTRUCTION. FLUSH WITH ADJACENT SURFACES. EXISTING FLOORS WHERE CONSTRUCTION HAS BEEN REMOVED SHALL BE PATCHED AND LEVELED TO MATCH EXISTING. 3. ALL EXISTING FURNISHES SHALL REMAIN. UNLESS SCHEDULED FOR NEW. CONTINUE EX15T FINISHES TO REMAIN. INTO NEW EXTENDED AREAS THAT ARE ADJACENT. PATCH AND REPAIR EXISTING TO MATCH NEW. PREPARE SUB57RATE5 TO RECEIVE NEW FINISHES WHERE SCHEDULED. FINISH ALL PATCHED OR EXTENDED WALLS TO THE NEAREST CHANGE OF DIRECTION. WALL TERMINATION. OR INTERSECTION. PREPARATION OF SUBSTRATES TO RECEIVE NEW FINISHES SHALL INCLUDE. BUT NOT LIMITED TO THE FOLLOWINGi • PATCHING AN/OR LEVELING OF FLOOR SLAB. • SKIMCOATING OF GYPSUM WALLBOARD SURFACES. • SANDING OF METAL FRAMES. ETC. 4. GENERAL CONTRACTOR SHALL NOTIFY ARCHITECT WITH ANY DISCREPANCIES IN WRITING UPON DISCOVERY. 5. CONTRACTOR TO MAINTAIN INTEGRITY OF ALL EXISTING STRUCTURAL ELEMENTS DURING CONSTRUCTION AND NOTIFY ARCHITECT WITH ANY ISSUES THAT MIGHT APPEAR DURING DEMOLITION UPON DISCOVERY. G. PATCH + REPAIR ALL EXISTING WALLS AND PREPARE TO RECEIVE NEW FINI5HE 5. 7. EXISTING FLOOR FINISHES TO BE REMOVED WHERE NEW FINISHES ARE SHOWN ON FLOOR FINISH PLAN. B. EXISTING CEILING + LIGHTS TO BE DEMOLISHED �mun Ir co 0 z00 c� O ►° N E O � W oago Ag �_ Q A A b E 10 1�1. 4-11 M N l lit O to H ,4, Z Ln o�0� 0 U 13 D O Z 0 darn L_ LL— i 4—) W c Z C01 w 0 � N w Seal cn p, AR '4 State of Floc leense 196063 Date: 4. 25. 22 Checked by: AZP Drawn: MAH J ob: 21-042 Sheet AD1 01 'L �L 1! I _L" !! 1 nslll�, •••*. ,1.1 �!! 1._S_ !4 I I!I IYII!.!_1 _ I ! I I I 1 1 I I' 111 If '._L I 111 I I II Ifj n 1 5 OACCESSORY PLAN 101 TOILET ELEVATION 4 TOILET ELEVATION SCALE, 3/8' = 1'-0' SCALE, 3/8' = 1'-O' O SCALE, 3/5' 1'-0' 51GNAGE TO MEET ADA AND FLORIDA ACCESSIBILITY GOD FOR BUILDING CONSTRUCTION — MOUNT ROOM SIGN ADJACENT TO LATC 51DE OF DOOR — 101 H.C. LE,NSIGN MOUNTING DETAIL 3'-4' 2 PROP05ED FLOOR PLAN SCALE, 1/4' = 1'-0' L( 1/4' x 2' LAG BOLTS 50LID BLOCK BETWEEN ME1 STUDS AS RI AS PER WALL TYPE COVER PLATE ESCUTCHEON 1 1/2' DIAMETER 5.5. GRAB BAR 1/2 1/2 DIA. NOTE, ALL GRAB BARS INCLUDING THOSE MOUNTED AT TUBS. SHOWERS. AND TOILETS AND TOILET MOUNTED GRAB BARS SHALL BE DESIGNED AND SUPPORTED AS TO WITHSTAND A LOAD OF NOT LE55 THAN 250 POUNDS APPLIED AT ANY POINT DOWNWARD OR HORIZONTALLY AS REQUIRED BY THE FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION. CPROVIDE SUFFICIENT BLOCKING BEHIND EACH GRAB BAR INSTALLATION) GRAB BAR ACHORING DETAIL SCALE, 3' = 1'-0' O O DISH WASMG 109 r ACCCCEESS 10 / �` IOG O,- 104 112 KEYED NOTES �1 WALL MOUNTED LAVATORY - SEE PLUMBING 0 EXISTING H.G. WATER CLOSET CTO REMAIN) 0 WALL MOUNTED SOAP DISPENSER 44 SURFACE MOUNTED PAPER TOWEL DISPENSER SURFACE MOUNTED TOILET TISSUE DISPENSER El DWALL MOUNTED CHANNEL FRAMED MIRROR 7D PIPE INSULATION KIT D30' x 48' CLEAR FLOOR SPACE DGO' x GO' CLEAR FLOOR SPACE 10 3G' GRAB BAR s 11 42' GRAB BAR 12 HC SIGN G HIGHEST OPERABLE OF WALL PART OF ACCE55ORY TOILET ACCESSORIES A�CCES�OFiY SPEGN�GATION SURFACE MOUNTED TOILET TISSUE DISPENSER BOBRICK B-G85 SURFACE MOUNTED PAPER BOBRICK B-2G2 TOWEL DISPENSER 3G' GRAB BAR BOBRICK B-G8OG X 3G SATIN FINISH WITH SNAP FLANGE 42' GRAB BAR BOBRICK B-G8OG X 42 SATIN FINISH WITH SNAP FLANGE WALL MOUNTED SOAP BOBRICK B-155 DISPENSER WALL MOUNTED MIRROR BOBRICK B-1G5 1830 GENERAL NOTES 1. FOR TYPICAL H.G. SIGN MOUNTING DETAIL, SEE DETAIL 'A' THI5 SHEET 2. FOR TYPICAL GRAB BAR ANCHORING DETAIL, SEE DETAIL 'B' THIS SHEET 3. FOR TYPICAL TOILET ACCESSORIES MOUNTING HEIGHTS. SEE DETAIL 'G' THIS SHEET 4. FOR CEILING HEIGHTS, SEE REFLECTED CEILING PLAN 5. USE WATER RE515TANT G.W.B. IN ALL OF TOILET ROOM WALLS PER 1210 FBG-B G. ALL PAINT IN TOILET ROOMS TO BE WATER-RE515TANT PAINT RShMI. al ) I FLOOR I ' I FLOOR WALL HUNG 5W PAPER TOWEL DISPENSER H.G. WAITER CLOSET I H.G. WATER CLOSET NOTE, 1. TYPICAL MOUNTING HEIGHTS UNLE55 OTHERWISE NOTED 2. THE FLUSH VALVE MUST BE LOCATED ON THE APPROACH SIDE OF ANY ACCESSIBLE WATER CL05ET TYPICAL MOUNTING HIEGHT5 SCALE, 1/2' = 1'-0' i9 I N t9 — 1 It L � N EXISTING BUSS STATII DMG low 23'-O' DDG 101 1 :4 I O N NOTE, X = 3G' MIN. IF Yl = GO' X = 42' MIN. IF Y1 54' PULL SIDE — -- �MANEUVERING CLEARANCE F-," NOTE, 22' Y1 - 48' MIN. MIN. 58• Yl = 54' MIN. IF THE DOOR HAS MINA CLOSER L - — J PULL 51DE PUSH SIDE --- --- --- - +, 1 NOTE, MANEUVERING Y2 = 42' MIN. a 24' I CLEARANCE Y2 = 45' MIN. IF THE DOOR HAS �� 1 MIN, BOTH A CLOSER AND A LATCH ! 24' N I MIN. PULL 51DE ' +-, j PUSH 51DE NOTE, Y2 = 42' MIN. 18' Y2 = 48' MIN. IF THE DOOR HAS MIN. A CL05ER MANEUVERING t- L t -■- CLEARANCE PUSH 51DE NOTE, X = 12' MIN. IF THE DOOR HAS BOTH A CLOSER AND A LATCH DDJ 77. MIANUNERNG CLEARANCES AT DOORWAYS SCALE, 3/1G' = 1'-0' MANEUVERING GLEARANGE ---�, 1 ! I I E �ITYP. MRLMEMIG 5 WNW DOOR SCALE, 3/1G' = 1'-0' 20 GA. STEEL CHANNEL FASTEN TO STRUCTURE. ABOVE 3 5/5' 25 GA- GALV. STEEL / 5"(UD5 AT 6'-O' O.G. FIRE BLOCKING AS PER FBG 717 LAY --IN ACOUSTICAL OR GYPSUM BOARD CEILING. 1/2' x 4B' WIDE G.W.B. APPLIED HORIZONTALLY OR VERTICALLY, CORNER JOINTS OVER 5T11D5, STAGGER 1G' O.G. OPPOSITE SIDES- ATTACH TO STUDS AND RUNNERS WITH 1' I-ONG TYPE '5' SCREWS AT THE JOINTS -- RUNNER CHANNELS 1/2' TO 3/4' FROM EDGES OF G.W.B. SCREWS SHALL BE SPACED 8' O.G. ALONG EDGES OF BOARD AND 12' O.G. IN THE FIELD. GOVE:R JOINTS WITH TAPE AND JOINT COMPOUND PER GA - WP -- 1200. INCREASE METAL STUD THICKNESS AS REQUIRED FOR PLUMBING AND ELECTRICAL. FIRE BLOCKING AS PER F13C 717 3 5/B' OR G' CSEE FLOOR PLAN) GALV. STEEL STUDS AT 1G' O.C, 20 GA.5TUD5 AT WALL MOUNTED EQUIPMENT 25 GA. GALV. STEEL CHANNEL FASTEN TO 5LA13 AT 24' O.G. FLOOR 51-AB DTYPICAL NON RATED PARTITION D� SCALE, 1 1/2' = l'-O' Al J SAME AS PARTITION TYPE 'A' EXCEPT NO BLANKET INSULATION. D SAME AS PARTITION TYPE 'A' EXCEPT WALL IS ONLY 4'-0' HIGH WITH AN 8' WIDE PLASTIC LAMINATE GAP. AA SAME AS PARTITION TYPE 'Al' EXCEPT USE G' METAL STUD. WALL LEGEND 4' TYP ! DOOR SYSTEM - REFER TO DOOR SCHEDULE 0 WINDOW SYSTEM - REFER TO WINDOW SCHEDULE METAL STUD PARTITION - REFER TO WALL TYPES - }-� SEE SHEET A101 FOR WALL TYPE DETAILS ! KEYED NOTES r(D MBING FIXTURE - SEE PLUMBING DRAWINGS FOR MORE INFO. L MOUNTED FIRE EXTINGUISHER MILLWORK OCATED DOOR FLOOR PLAN GENERAL NOTES 1. DIMENSIONS ARE FROM CENTER LINE OF WALL STUD FRAMING. 2. GENERAL CONTRACTOR TO NOTIFY ARCHITECT AFTER LAYOUT 15 DONE AND WALL TRACK 15 IN PLACE PRIOR TO FRAMING ANY WALLS 3. GENERAL CONTRACTOR TO NOTIFY ARCHITECT OF ANY DISCREPANCIES PRIOR TO COMMENCING WITH ANY WORK 4. GENERAL CONTRACTOR TO PROVIDE WOOD BLOCKING IN WALLS A5 REQUIRED FOR NEW CABINETRY. ACCESSORIES. ETC. 5. PATCH AND REPAIR EXISTING CONCRETE SLAB. PROVIDE SKIM COAT OR FLOAT IF REQUIRED. PREPARE TO RECEIVE NEW FLOOR FINISHES. PATCH AND REPAIR EXISTING REMAINING WALLS DAMAGED DURING DEMOLITION. G. CONTRACTOR TO COORDINATE ALL PLUMBING. ELECTRICAL AND MECHANICAL REQUIREMENTS FOR ALL EQUIPMENT WITH EQUIPMENT SUPPLIER. 7. EXISTING LAY IN CEILING TILES, GRID. LIGHTS + DIFFUSERS TO REMAIN. ADJUST CEILING AS NEEDED PER NEW LAYOUT. oil I I III Z LO (3 Q 4- Q Z O J Q 0 O l� ED l� i �<� J UJI 0 -p ODIC a_ E- �W w A r~ a Seal �E OF Fto P. g'�PO�E.W Z. AR96063 State of eatie'96063 Date: 4. 25. 22 Checked by: AZP Drawn: 1MIAH Job: 21-042 Sheet Al 01 0 TYPICAL RTU CURB TO SUPPORT ANGLE FRAME DETAIL TYPICAL RTU CURB TO SUPPORT ANGLE FRAME DETAIL TYPICAL RTU UNIT FASTEN NEW RTU UNIT MAX WEIGHT = 700LBS TO NEW CURB w1 IX14 x 6` HWH SELF -GRILLING SCREW WITH A 03 DRILL MAX HEIGHT = V-0" POINT AND ZINC COATED SPACED AT 17 O.C. MAX (ALL 4 SIDES) (BUiLDEX OR EQUAL P.T- 2x4 (SYP#2) It CONT. ATTACH CURB TO STEEL WOOD SUPPORT ATTACH CURB TO STEEL ANGLES WITH 14" x 2.5 RL OCIONG TYPICAL ANGLES WITH 114" x 2.5' HILTI SELF DRILLING HILTI SELF DRILLING SCREWS ® 1r OIC NEW PRE-ENG I PRE-FAB SCREWS a 12" O/C AROUND PERIMETER. 20 GA (MIN.) ROOF CURB. AROUND PERIMETER- FAS1 LNt;KS MUST SIAN 1 CONTRACTOR TO FIELD FASTENERS MUST START WITH 2" OF THE ENDS OF VERIFY THICKENSS AND WITH 2" OF THE. ENDS OF ALL SIDE OF THE CURB. NOTIFY E.O.R. IF FIELD ALL SIDE OF THE CURB_ + —CONDITIONS DIFFER. PROVIDE JOIST REINF. AT CONCENTRATED LOAD 'TYPICAL G.C. MUST PROVIDE 2x BLOCKING UNDER DECK LOCATIONS PER JOIST REINFORCING AT AT LOCATION OF CURB, CONCENTRATED LOAD DETAIL" WHERE APPLICABLE CURB ATTACHMENT PARALLEL TO DECK SPAN. NOTES T CONTRACTOR IS TO PROVIDE FRAME UNDER ALL RTUs. 2 G.C. MUST CONTACT STRUCTURAL ENGINEER OF RECORD IF UNIT EXCEEDS MAXIMUM HEIGHT ANWOR WEIGHT. TYPICAL RTU UNIT FASTEN NEW RTU UNIT MAX WEIGHT = 700LBS TO NEW CURB W1 114.14 x 6" HWH SELF -DRILLING SCREW WITH A #3 DRILL MAX HEIGHT = V-0" POINT AND ZINC COATED SPACED AT 12" O.C. MAX (ALL 4 SIDES) (BUILDEX OR EQUAL) P.T. 2x4 (SYPIII2) x CONT. WOOD SUPPORT PR OCKING. TYPICAL... NEW PRE-ENG I PRE-FAB 2D GA (MIN.) ROOF CURB. CONTRACTOR TO FIELD VERIFY THICKENISS AND NOTIFY E.O.R. IF FIELD +—CONDITIONS DIFFER. STEEL ANGLE FRAME, SEE TYPICAL DETAIL. REQUIRED AT ALL RTU LOCATIONS. DECK MUST BE WELDED TO ANGLE FRAME 36-7 (EACH FLUTE TO ANGLE) CURB ATTACHMENT PERPINDICULAR TO DECK SPAN. NOTES: 1. CONTRACTOR IS TO PROVIDE FRAME UNDER ALL RTUs. 2 G.C. MUST CONTACT STRUCTURAL ENGINEER OF RECORD IF UNIT EXCEEDS MAXIMUM HEIGHT ANWOR WEIGHT. TYPICAL ROOF OPENING DETAIL NOTES- T ANGLES ALL SIDES UNLESS BEAMS SHOWN ON PLAN: L 2" x 2" x 318' FOR "W" `_ 2'-0' L 3" x 3" x 31W FOR "W" `_ 4'-0" L 4" x 4" x 318' FOR "W" ` 6'-0" 2. FOR 'Vr > B'-0", CONTACT STRUCTURAL ENGINEER OF RECORD FOR FRAMING REQUIREMENTS. t—NOTE #1 OR JOIST T / PROVIDE FRAMES FOR OPENING OPENINGS 8" OR MORE (LARGER DIMENSION OR DIAMETER), INCLUDING ROOF DRAINS AND SUMPS. 'W FRAME PLAN NOT TO SCALE SEAT SAME SIZE AS SUPPORT FRAME—� 11a^ SHOP SEAT DETAIL NOT TO SCALE TYPICAL RTU ROOF OPENING DETAIL NOTES: 1. PROVIDE AT PERIMETER OF ALL ROOFTOP MECHANICAL UNITS AND OPENINGS AS REQUIRED. 2, SEE MECHANICAL DRAWINGS FOR OPENING SIZE AND LOCATION, 3. PROVIDE L 3x3x5116" AT ROOF SUMPS. METAL ROOF DECK SEE PLAN SEE MECHANICAL DRAWINGS FOR OPENING DIMENSIONS —L 6x4x8116" (LLV), TYPICAL 4 SIDES L 6x4x318" CUP (4 REQUIRED) STEEL JOIST 5LL FLAN FOR BALANCE OF INFO TYPICAL ROOF OPENING DETAIL NOT TO SCALE TYP FRAMES TO JOIST, TYP. CEILING LEGEND EXPOSED CEILING GYPSUM DRYWALL CEILING/SOFFIT NEW 2' x 4' SUSPENDED CEILING GRID SYSTEM WITH LAY -IN ACOUSTICAL CEILING TILES NEW 2' x 4' SUSPENDED CEILING GRID SYSTEM WITH 51GRUB15ABLE LAY -IN ACOUSTICAL CEILING TILES CEILING MOUNTED FAN 2x4 LIGHT FIXTURE. 2'x2' LIGHT FIXTURE HANGING/PENDANT/CHANDELIER LIGHT FIXTURE O RECE55ED CAN DOWN LIGHT FIXTURE - SEE ELECTRICAL FOR MORE INFORMATION ® MECHANICAL SUPPLY REGISTER - SEE MECHANICAL ROOF CURB/OPENING DETAILS FOR MORE INFORMATION Di SGALEs N.T.S. MECHANICAL RETURN REGISTER - SEE MECHANICAL FOR MORE INFORMATION it EQUAL Id. 5'-5' 5`-5' EQUAL 2'-11' 5'-5' 5'-5' 5'-5' G'-G3/4' ® MECHANICAL TRANSFER GRILLE - SEE MECHANICAL FOR MORE INFORMATION D REFLECTED CEILING PLAN SCALE 3/1G' - 1'-0' ® EXHAUST FAN - SEE MECHANICAL FOR MORE INFORMATION METAL STUD FASTENING NOTES 1. ALL METAL FRAMING FOR GYPSUM WALLBOARD CEILING SMALL BE 25 GAUGE TYPICAL CU.N.O.) 2. 1MTL. STUDS SHALL BE CONNECTED TO STRUCTURAL STL. w/ C3) 0.145' RAMSET POWDER DRIVEN FASTENERS 3. MTL. 5TUD5/CLIP ANGLE SMALL BE CONNECTED TO MTL. STUDS w/ MIN C431 #12-14 TEK SCREWS. 4. CONTINUOUS TRACK SMALL BE CONNECTED TO STRUCTURAL 5TL. w/ C23 0.145' RAM5ET POWDER DRIVEN FA5TENER5 AT 1G' O.G. 5. CONTINUOUS TRACK/STUDS/CLIP ANGLES SHALL BE CONNECTED TO GONG./CMU w/ C2) 1/4' x 1 1/4' TAPGON FASTENERS AT 24' O.G. G. CONNECT MTL. 5TUD5/CLIP ANGLES TO WOOD TRUSSES w/ C4) 1/4' WOOD SCREWS. 7. CONNECT SHEATHING TO MTL. STUDS w/ #12-14 TEK SCREWS AT G' O.0 B. CONTINUOUS TRACK SHALL BE CONNECTED TO ROOF DECK w/ C2) #10 TEK SCREWS AT 24' O.G. 9. AS REQUIRED. THE CONTRACTOR SHALL PROVIDE GLIP ANGLES FOR ALL METAL 5TUD5 50 PROPER ALIGNMENT CAN BE ATTAINED. CLIP ANGLES SHALL MATCH OR EXCEED THE STUD GAGE. 11111111 �umu T a0 W p I.- N MEMOo s L .m <a (� ,j) X203 So a g. L ell t E '`ti a— h c +, 1i ZI z T--1 It if i IL Q 4- _o Q Q Z O LL-I Q °- vu oHmo 0 IU ~ (1 >-- W d N 1� w A F+ a+ Seal �l cjf, F t 0 CO .V �S Andl Is Stale of Florida Lieense '96OW Date: 4. 25. 22 Checked by: A%P Drawn: MAII Job: 21-042 Sheet A601 1' _II' i 1 10 2 SERVING/GA5HIER SCALE, 3/B' = 1'-O' SECTION ABBREVIATION5= • CPT, CARPET • FLl FLAT LATEX • LVTl LUXURY VINYL TILE • 5Gs 5EMI-GLO55 • VB- VINYL BA5E • LF, LIQUID FLOOR CPOLYUREA/POLYA5PARTIG EPDXY 5Y5TEM) \ / �3)I SERVING/CAShtIER SCALE, 3/8' = 1'-O' ROOM FINISH SCHEDULE ROOM NO. ROOM NAME FLOOR BASE WALLS REMARKS NORTH EAST SOUTH WEST 101 DINING CPT VB FL FL FL FL - 102 DINING CPT VB FL FL FL FL - 103 5ERVING/CA5HIER LVT VB FL FL FL FL - 104 OFFICE CPT VB FL FL FL FL - 105 ATTIC AGGE55 - - - - - - - lOG KITCHEN LF VB SG SG 5G 5G - 107 TOILET LF VB SG SG 5G 5G 108 KITCHEN LF VB 5G 5G 5G SG lO9 1 D15H WASHING LF VB 5G SG 5G SG - 110 TOILET LVT VB 5G 5G 5G SG - 111 TOILET LVT VB 5G SG 5G 5G - 112 HALL LVT VB FL FL FL FL - MILLWORK ELEVATION - KEYNOTES 10 COUNTER TOP - MATERIAL SELECTED BY OWNER 0 4' HIGH BACK5PLA5H OADJUSTABLE SHELVES OGYPSUM BOARD SOFFIT OBASE - SEE ROOM FINISH SCHEDULE EXISTING PA55-THRU WITH STAINLESS STEEL SERVING COUNTER CTO REMAIN) FLOOR FINISH LEGEND MATERIAL LIST LVT: INTERFACE. LEVEL SET. A00204 BEECH CONTACT. SHANE STEED 813-313-0329 f I I I EXI5TING FLOORING TO REMAIN CARPET: INTERFACE. RECLAIM 12753OAK00. AGED BROWN 104149 CONTACT. SHANE STEED 813-313-0329 BASE: MANNINGTON, BARK 9O4 CONTACT. ALI AKERS 941-932-3245 PAINT: TOP. BENJAMIN MOORE. HC-172 REVERE PEWTER BOTTOM: BENJAMIN MOORE. HC-87 ASHLEY GRAY TRIM: BENJAMIN MOORE. HC-85 FAIRVIEW TAUPE LAMINATE: COUNTER SURFACE, WIL5ONART. POTTERS CLAY 5011K-22 CABINETS: WILSONART. 5TICKLEY OAK. 17003K-57 CONTACT. TERESA FINCH 813-293-0588 LIGHTING: ELK GROUP. THOMAS. BLAKESLEY 1 LIGHT PENDANT IN OIL RUBBED BRONZE WITH FROSTED GLA55, 8". CN200151 CONTACT: KRI5TIN CONROY 813-777-1304 VINYL OPTIONS: ARC COM CONTACT, COURTNEY DAVID50N 727-510-402G MAHARAM CONTACT, ALY50N BAKER 813-4G3-G428 1--�....................... .............. ......I...1.......1.........,........,................,.................................................................................................................................. ATTIC:":':":":":".":":':":":":":":':":':':':':'::':':':':':'::::: ::::::::::....... I -: ..................................................... I .........................................................:.................................................... . :................................. d:: ................ ... ......A-...........-.j) .'-I......-..*-.......11-..'-....I . 1.".......I. 1 ...1..I.T-III.... L.....* CCESS ..'.'.'.'.'.-.'.'.'."."....'.'.'.'.".'.".'.'.'.'..'.'.'..'.'.'.'.'.".'.".'.'.'.'.'.."..".'.".".'.".".".".'.".".".".'.".'.'.'.'.".'.'.'.".'.'.'.'..'.".'.'.'.'.'.'.'.'.'.'.'.".'.'.".".".'.'.'.'.'.'.'.'.'.'.'.'.'.'.'.".'.'.'.".'.'.'.'.'.'.".'.'.'.'...............................................................'.'.. ........I........................... ..I..................I...............................................I.................... 105.'.'.'.".'.'.'.".'.'.'.'.'.".'.'.'.'.'.'.'.'.'.'..'.'.'.'.'.'.'.'.".'..'.'.".'.'.'.'.'.'.'.'.'.'.'.'.".'.'.'.'.'.'.'.'.'.".'.'.'.'.'.'.'.'.'.'.'.'.'.'.'.'.'.'.'."..'.'.'.'.'..'.'.'.'.'.'.'.'.'.'.'.'.'.'.'.'.'.'.'.'.'.'.'.'.'.'.'.'.' . . '• '. ".'.'.'. ".'.'.'.'.'. '.'.'.".'. .".'.'.'.'.'.'.'.'.".'. ".'.'.".'. .'. ".'.'.'.'. ".'.'.'.'."..".'.".'.".'.".'.'.".".".'.".'.".'....•.•...•...'...•...... ... ..•.•........ .....,.-.•.•.•.•.-.•.•... •.•.'.•.•.•..., ..•........ .......•.....•.-...•.•...•.,...'.•.......'...'.,.'...•...•...•...•...................•.•.'.•.'...'...•.'...•...'...'.'.•.•.'.'.'.•.....-. b4.'.".'.'.'.'.'.'.'.'.'.".".".'. .'..".'.".'.'.'.'.'.'.'.".'.'.'.".".'.".'.".'.'.'.".'.'.'."..'.'.'.".'.'.'.".".'.".'.".'.'.'.".'.".".".".'.'.".'.".".".'.'.".'.".'.'.'.'.".....'.'.....'.'.".....'.'.'.".'....".'.....'."."......".".....'.'.....'.'.'.....".".....'.'.".....'.".....".'.'.....".'.....'.'.'.....'.'....."."."......".'.....' 1 ............................ ............................................................................................................................................................................................................... ::":':':':':':':":':":':':":":":":':":":":":':":':':':":':":':":".":":":":"...'.:":':':":':":':":':':":' :' :':":. ..:...........:.......:...:.:.:.........:.........:.:.:...:.................:.....:...:...:............ ............................ .............. . . . .........................................................ow...................- ..-............................................ ....................................................................102.................................................I......I................ MI . L 1 .... .. .. ... .. 105 . ..... ... .':"...:":'.':":':".':':".':":":":":":".':":':".":':":':":':':':':':'.'.':'.':":'.":'.':':":'.".":".'.':':':'.':'.":":".".":':':":':':':":":' ........................:':':':':':".':':':":".':":':':':':' :' :':".'..':':':' ................................................................................................................................................... ................................................................ ................................................................................................................................................... OO.................................................................................................................................................. .'.'.".'..'."..'.'.'.'.".".'.'.'.'.'.'.'.'.".'.".'.'.'.'.'.'.'.".'.'.'.'.'.'.'.'.'.'.'.'.'.'.'.'.'.'.'.'.".'.".'.':::.:.:.......Cs ' :::::: _ :::::: _ :: .................................................. ,p.................................................................... .101 .'..'._'..............................................................................................................................................' OLET TOLET :.:.:.:.:.:.:.:.:.:.:.:.:.:.:. o.'.'.'.'.'.'..'..'..'.'.....'....'... ' ' ''.....'I .'..'..'....'.......'.. I'.'.'..'.'.'..'.'.'.'..'.'....'.'..'..'....'. � ..'.'.'.'.'.'.'.'.'• ..'.'.'.'...........'.'. ........................ � ..'..'..'I ...'. . ......................................................-...............'..'.'..'..'..'.'..'...........................................'................... ................................................................................................................................................ ................................................................................................................................................. ............................................................................................................................................... ............ .. ................................................................................................................................ .......................................................................................................................—. .................... ............ .. ................................................................................................................................ .............................................................................................................................................. ........... .. ................................................................................................................................ .............................................................................................................................................. ............ .. ................................................................................................................................ 112 .'.'..'.".'.".'..".'.'.'.'.'.'.'.'.'.'.'.'.'.'.'.'.'.'.'.'.'.'..'.'.'.'.'.'.'.'.'..'.'.'.'.".'.'.'.'.'.".'.'.'.'.'.'.'.'.'.'.'.'.'.'.'.'.'.'.'.'.'.'.'.'.'.'.'.'.'.'..'.'.'.'.'.'.'.'.'.'.'.'.'.'.'.'.'.'.'.'.'.-.-.'.".'.'.'.".'.'.'.'.'. ..'.'. .............................................................................................................................................. ............ .. ................................................................................................................................ .............I................................................................................................................................ '.'. EXISTING... :.:.:.:.:.:.:.:.:.:.:.: Bijs8'IzfiA' '. ... ... ....... .. .. ... .. ... CPT+ CARPET PT, PORCELAIN TILE LVTv LUXURY VINYL TILE �1111111 1 a' to 0 1 (A z v if € Wj -d) 1 9 L A V = -1-5 < LLI = > o a R PR? �a � L � _g -L 2 2 r i >Q aI - 10 9 = a a u II x $? CL G Iis t 4-) k-�- _ R I 1 4 Iq o � it r � " ? T�� � Ie Z ,--I � z Q - O plan --- w- n di 4- ~ Q d > O - I— U _.I < M 2 T 93 kn =) Q QL C > O 1— 9 a N V,JII_ o A- <alf- "j L- O LL. -e 0 J — W L N <(0Im `-4 r 9 4-) LLJ (() >-- H c OLr-,r- Z m (LW LO =) u- E.-I C-) N _2 'W R w o x y A F a, Seat f, OF R4 �P W Z. ' �� y �,oRpq, :O Q v •? • ° N� . — * . -p�. AR96063 ,t °^ .s , , `�� RE GN An is State of f'lorfda Lice�ice °9(i1163 Date: 4. 25.22 Checked by: AZY Drawn: MAH Job: 21-042 Sheet A801 i FURNITURE/FLOOR FINISH PLAN SCALE, 1/4' = 1-0' F 0 0 D S E R U I C E E Q U I P M E N T S C H E D U L E MK. QTY DESCRIPTION ELECTRICAL WATER WASTE GAS REMARKS Q IJi Y = J � Q �.. w� 0 � � OU � � w cc, w � g z O 18 17 1 3 3 4 �� �d III � I II 7 5 g 11 IS � �11 gl I I 0 6 12 o�w 13 E 10 o Q I J � C� 0 0 I g 1g I I ( I i u 36 35 34 40 I 0 0 J ITS DTI w II II O Li ° � LL� ,r N o 1- II o01 II EXISTING BUSS STATI NOTES: 1. VERIFY LEGEND WITH EXISTING EQUIPMENT. 2. VERIFY LEGEND WITH NEW CUT SHEETS.. z FOOD SERVICE — EQUIPMENT PLAN SCALES 11 1771, 0 100 Zi 41ED U 50LO 0 El 11 �IIIIIII Q z l z Q(� CIL oQJ< a vu o�m0 v°CQQ0-5 L- LL y c� Nd0 ('�� Go O L H � N V w Cl A r. '0 i� Date: 4. 25. 22 Checked by: AZP Drawn: MAH Job: 21-042 Sheet FS1 01 It PLUMBING SPECIFICATIONS SCOPE: THE CONTRACTOR SHALL VISIT THE SITE AND EXAMINE THE DRAWINGS AND SPECIFICATIONS BEFORE SUBMITTING A PROPOSAL. ALL WORK SHALL BE IN ACCORDANCE WITH THE FLORIDA BUILDING CODES SEVENTH EDITION (2020), WITH AMENDMENTS, AND LOCAL CODES AND ORDINANCES. INSTALLATION SHALL COMPLY WITH THE CODE REFERENCED STANDARDS SET BY NFPA, ASHRAE, ASPE, SMACNA, NEC AND UL. THE SYSTEMS, EQUIPMENT, DEVICES AND ACCESSORIES SHALL BE INSTALLED, FINISHED, TESTED AND ADJUSTED FOR CONTINUOUS AND PROPER OPERATION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR HIS WORK FITTING IN PLACE AND SHALL COORDINATE WITH OTHER TRADES TO AVOID INTERFERENCE WITH THEIR WORK. THE INFORMATION GIVEN HEREIN AND ON THE DRAWINGS IS AS EXACT AS COULD BE SECURED, BUT ITS EXTREME ACCURACY IS NOT GUARANTEED. THE DRAWINGS ARE DIAGRAMMATIC, INTENDED TO SHOW GENERAL ARRANGEMENT, CAPACITY AND LOCATION OF VARIOUS COMPONENTS, EQUIPMENTS, AND DEVICES. IF WORK IS REQUIRED IN A MANNER TO MAKE IT IMPOSSIBLE TO PRODUCE FIRST CLASS WORK, OR SHOULD DISCREPANCIES APPEAR AMOUNG THE CONTRACT DOCUMENTS, OR BETWEEN THE CONTRACT DOCUMENTS AND THE MANUFACTURER'S RECOMMENDATIONS,THE CONTRACTOR SHALL REQUEST INTERPRETATION BEFORE PROCEDING WITH WORK. CONTRACTOR SHALL FURNISH AND INSTALL ALL MINOR ITEMS WHICH ARE OBVIOUSLY AND REASONABLY NECESSARY TO COMPLETE THE INSTALLATION WHETHER OR NOT SPECIFIED IN THE DOCUMENTS. REQUIRED COORDINATION: ALL WORK SHALL BE COORDINATED WITH ALL TRADES INVOLVED. OFFSETS IN DUCTS AND PIPING (INCLUDING DIVIDED DUCTS) AND TRANSITIONS AROUND OBSTRUCTIONS SHALL BE PROVIDED AT NO ADDITIONAL COST TO THE OWNER. CONSTRUCTION PLANS: IN GENERAL, PLANS AND DIAGRAMS ARE SCHEMATIC ONLY AND SHOULD NOT BE SCALED. REQUIRED ACCESS: CONTRACTOR SHALL ENSURE THAT ALL EQUIPMENT AND DEVICES THAT REQUIRE REPLACEMENT, SERVICING, ADJUSTING OR MAINTENANCE SHALL BE LOCATED TO ALLOW EASY ACCESS AND SPACE FOR REMOVAL OF INTERNAL ASSMBLIES, IF REQUIRED. CONTRACTOR SHALL PROVIDE ACCESS PANELS WHERE REQUIRED TO ALLOW ACCESS, EVEN IF NOT INDICATED ON THE DRAWINGS AT NO ADDITIONAL COST TO OWNER. WIND RESISTANCE: ALL EQUIPMENT, APPLIANCE AND SUPPORTS LOCATED EXTERIOR OF THE FACILITY SHALL BE INSTALLED TO RESIST WIND LOADS AS DETAILED IN THE BUILDING CODE. CUTTING AND PATCHING: ALL OPENINGS AROUND DUCT OR PIPE PENETRATIONS THROUGH SMOKE OR FIRE RATED FLOORS, CEILINGS OR WALLS SHALL BE SEALED AIRTIGHT WITH MATERIALS HAVING A RATING EQUAL TO THE MATERIAL OF THE WALL, CEILING OR FLOOR PENETRATED. ALL EQUIPMENT WILL HAVE A PERMANENTLY FIXED TAG CORRESPONDING TO THE EQUIPMENT TAG ON THE ENGINEER'S DRAWINGS. FIRESTOPPING: UL APPROVED MATERIALS AND METHODS SHALL PROTECT THE PENETRATIONS OF FIRE AND/OR SMOKE RATED WALLS, CEILINGS OR FLOORS. THE RATING OF THE FIRESTOPPING SHALL EQUAL THE RATING OF THE RATED ASSEMBLY. ALL INSULATION SHALL HAVE COMPOSITE FIRE AND SMOKE HAZARD RATINGS AS TESTED BY PROCEDURE ASTM E-84, NFPA-225, UL-723 NOT EXCEEDING: FLAME SPREAD 25 SMOKE DEVELOPED 50 FUEL DISTRIBUTED 50 ACCESSORIES SUCH AS ADHESIVE, MASTIC, CEMENTS AND TAPES SHALL HAVE THE SAME COMPONENT RATING AS LISTED ABOVE. SERVICE AND PERMITS: CONTRACTOR SHALL MAKE ALL ARRANGEMENTS WITH UTILITY COMPANIES FOR SERVICE AND CONNECTIONS AND SHALL PAY FOR PERMITS. SHOP DRAWINGS: EACH TRADE SHALL PREPARE AND SUBMIT SHOP DRAWINGS IN ACCORDANCE WITH PROCEDURES OUTLINED IN DIVISION 1. RESPONSIBILITY FOR ERRORS OR OMISSIONS IN THE SUBMITTALS SHALL NOT BE RELIEVED BY THE ARCHITECT'S OR ENGINEER'S REVIEW. ENGINEER'S PROCESSING WILL NOT CONSTITUTE A COMPLETE CHECK BUT WILL INDICATE ONLY THAT A GENERAL METHOD OF CONSTRUCTION AND DETAILING IS SATISFACTORY. AT A MINIMUM SUBMITTALS SHALL INCLUDE FIXTURES, VALVES, PIPING, INSULATION AND ACCESSORIES. START-UP: CONTRACTOR SHALL STARTUP ALL EQUIPMENT AND FOLLOW THE MANUFACTURER'S START-UP PROCEDURES. OPERATING AND MAINTENANCE DATA: SUBMIT THREE COPIES OF MANUFACTURER'S OPERATING AND MAINTENANCE INSTRUCTIONS AND SPARE PARTS LIST FOR EACH PIECE OF EQUIPMENT. SUPPLEMENTARY SUPPORTS: CONTRACTOR SHALL PROVIDE ALL SUPPLEMENTARY STEEL REQUIRED TO SUSPEND MECHANICAL EQUIPMENT AND MATERIALS, IN ORDER TO PROVIDE A "VIBRATION -FREE" RIGID INSTALLATION. DIELECTRIC UNIONS: PROVIDE DIELECTRIC UNIONS OR FLANGES AT CONNECTIONS OR CONTACT BETWEEN PIPES OF DISSIMILAR METALS. WATER PIPING: WATER PIPING SHALL BE CPVC TUBING. TUBING, FITTINGS AND CEMENT SHALL MEET ASTM D-2846, 100 PSI ® 1807 CONTINUOUS RATING. CPVC TUBING AND FITTINGS SHALL MEET 25/50 FLAME SPREAD/SMOKE DEVELOPED REQUIREMENTS FOR PLENUMS. CONTRACTOR SHALL INSTALL CPVC IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. CONTRACTOR SHALL PROVIDE FOR EXPANSION AND CONTRACTION OF TUBING. TUBING SHALL BE SLEEVED AT PENETRATION OF CONCRETE SLABS OR WALLS. CPVC TUBING SHALL BE BFGOODRICH FLOWGUARD GOLD OR APPROVED EQUAL. INSTALL PIPE SUPPORTS AT 3-FOOT INTERVALS FOR SIZES 1" OR SMALLER; INSTALL PIPE SUPPORTS AT 4-FOOT INTERVALS FOR 1-1/4" AND LARGER. WATER HAMMER ARRESTORS: INSTALL WATER HAMMER ARRESTERS AT EACH HOT AND COLD FIXTURE SUPPLY. EXPOSED PIPING: EXPOSED PIPING SHALL BE POLISHED CHROMIUM ON EITHER BRASS OR BRONZE. PROVIDE ADA INSULATED WATER AND WASTE LINE COVERINGS FOR WALL HUNG SINKS AND LAVATORIES. VALVES: ALL VALVES SHALL HAVE A MINIMUM OF 125 PSIG WORKING PRESSURE. VALVES AND COCKS MAY NOT BE INDICATED IN EVERY INSTANCE ON THE DRAWINGS, BUT WHETHER OR NOT SHOWN, ALL VALVES, COCKS AND CHECK VALVES NECESSARY FOR THE PROPER OPERATION OF THE SYSTEM SHALL BE FURNISHED AND INSTALLED. INSTALL ISOLATION/SHUT-OFF VALVES AT ALL MAIN RISERS, AND MAIN BRANCH TAKEOFFS. INSTALL ISOLATION/SHUT-OFF VALVES ON EACH INLET AND OUTLET OF EACH PIECE OF EQUIPMENT. PROVIDE A FLANGE OR UNION BETWEEN THE VALVE AND THE EQUIPMENT TO PERMIT DISCONNECTION, REMOVAL AND SERVICE. STERILIZATION OF DOMESTIC WATER SYSTEM: THE ENTIRE DOMESTIC WATER DISTRIBUTION SYSTEM SHALL BE THOROUGHLY STERILIZED AS REQUIRED BY THE HEALTH AUTHORITY OR WATER PURVEYOR HAVING JURISDICTION, OR IN THE ABSENCE OF A PRESCRIBED METHOD, THE PROCEDURE DESCRIBED IN EITHER AWWA C651 OR AWWA C652, OR AS DESCRIBED IN SECTION 610 FBC-P. NATURAL GAS SYSTEM: A SERVICE LINE, METER AND PRESSURE REDUCING VALVE HAS BEEN FURNISHED BY THE LOCAL GAS UTILITY COMPANY. THE COMPLETE GAS PIPING SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH SEVENTH EDITION FBC (2020) - FUEL GAS CODE. ABOVE GROUND GAS TO BE SCHEDULE 40 BLACK STEEL PIPING, ASTM A53. BELOW GROUND TO BE POLYETHYLENE GAS PIPING WITH CODE REQUIRED TRACER WIRE (FBC-FG, SECTION 404.17.3), ASTM D 2513. GAS PIPING INSTALLED UNDER SLAB SHALL BE RUN IN STEEL CONDUIT AND SEALED IN ACCORDANCE WITH FBC-FG, SECTION 404.14. PROVIDE UNION AND GAS SHUT-OFF VALVE TO EACH PIECE OF GAS FIRED EQUIPMENT OR APPLIANCE. PIPE INSTALLATION MUST BE TESTED IN ACCORDANCE WITH FCB-FC, SECTION 406. VENTING: THE STACKS SHALL BE EXTENDED THROUGH ROOF OF BUILDING TO POINTS NOT LESS THAN 12" ABOVE ROOF. VENTS SHALL BE OFFSET AS REQUIRED TO PENETRATE ROOFS AT LEAST 3 FEET FROM THE RIDGE OR EDGE OF BUILDING AND 10 FEET FROM ANY FRESH AIR INTAKE OR OPERABLE WINDOW OR DOOR, SANITARY, WASTE. AND VENT PIPING: ALL BURIED AND UNBURIED PIPING AND FITTINGS SHALL BE SCHEDULE 40 PVC-DWV. (SOLID CORE) SLOPE OF SANITARY OR DRAINAGE PIPING 2-1 /2" AND SMALLER SHALL BE A MINIMUM OF 1 /4" PER FOOT; PIPING 3" AND LARGER SHALL BE SLOPED A MINIMUM OF 1 /8" PER FOOT. CLEANOUTS WILL BE LOCATED NOT MORE THAN 100 FEET APART AND AT EACH CHANGE OF DIRECTION GREATER THAN 45' ALONG THE HORIZONTAL DRAIN. CLEANOUTS SHALL BE INSTALLED AT BASE OF EACH STACK. CONCEALED CLEANOUTS SHALL HAVE CAST BRASS CHROMIUM PLATED FLAT ACCESS COVER PLATE. FLOOR DRAINS/SINKS: FLOOR DRAINS SHALL BE CAST IRON AND ADJUSTABLE TO ACCOMMODATE THE FINISHED FLOOR. FLOOR SINKS SHALL HAVE AN ACID -RESISTANT ENAMELED INTERIOR. STRAINERS SHALL BE PROVIDED WITH BARRIER -TYPE TRAP SEAL PROTECTION (ASSE 1072) AND FLASHING FLANGE OR CLAMP, UNLESS OTHERWISE INDICATED. PLUMBING FIXTURES AND TRIM: PLUMBING FIXTURES SHALL BE FURNISHED AND INSTALLED IN A NEAT AND WORKMANLIKE MANNER WITH PROPER CONNECTIONS TO SUPPLY AND DRAINAGE PIPING. ALL FIXTURES SHALL BE FREE OF FLAWS AND DEFECTS OF ANY SORT IN MATERIAL AND WORKMANSHIP AND SHALL OPERATE PERFECTLY WHEN INSTALLED IN ACCORDANCE WITH MANUFACTURER'S DIRECTIONS. CONTRACTOR SHALL PROVIDE ROUGH -IN, AND SHALL CONNECT ALL FIXTURES TO THE PLUMBING SYSTEMS. ALL FIXTURES TO BE PROVIDED WITH CHROME -PLATED SUPPLIES AND STOPS. PROVIDE 17 GAUGE CHROME -PLATED BRASS TRAPS FOR ALL FIXTURES WITHOUT INTEGRAL TRAPS. PROVIDE CONCEALED ARM CARRIERS AND SUPPORTS FOR ALL FIXTURES REQUIRING SAME. PIPE INSULATION: INSTALL INSULATION PRODUCTS IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS AND IN ACCORDANCE WITH RECOGNIZED INDUSTRY PRACTICES. SEAL ALL JOINTS, BREAKS, TEARS AND PENETRATIONS WITH FIRE RETARDENT, VAPOR BARRIER MASTIC. COVER VALVES, FITTINGS AND SIMILAR ITEMS IN EACH PIPING SYSTEMS. INSULATE ALL DOMESTIC HOT WATER PIPE WITH 1" THICK FIBERGLASS SECTIONAL PIPE COVERING WITH CANVAS JACKET OR ARMAFLEX AP (ASTM E-84). TESTING: TEST ALL WASTE AND VENT PIPING FOR A PERIOD OF NOT LESS THAN 8 HOURS BY CAPPING OR PLUGGING. ALL JOINTS TO A LEVEL OF THE HIGHEST FIXTURE OR FITTINGS. FILLING THE SYSTEM WITH WATER, AND OBSERVING FOR LEAKS. TEST WATER PIPING AT 100 PSIG FOR A PERIOD OF 8 HOURS, OBSERVING FOR ANY VISIBLE LEAKS. TEST PIPING AGAIN WITH FIXTURES INSTALLED. REPAIR ANY LEAKS FOUND BY REMAKING JOINT. DO NOT USE CAULKING OR SIMILAR METHODS TO CORRECT LEAKS. UPON REPAIRING ANY LEAKS FOUND. AGAIN TEST THAT PORTION OF THE SYSTEM AS DESCRIBED ABOVE. EQUIPMENT FURNISHED BY OTHERS: WHERE SHOWN ON THE DRAWINGS, THE CONTRACTOR SHALL MAKE ALL PIPING CONNECTIONS TO EQUIPMENT FURNISHED BY OTHERS. THIS WORK SHALL INCLUDE FURNISHING AND INSTALLATION OF ALL WATER AND DRAIN PIPING. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH RECOMMENDATIONS OF EQUIPMENT MANUFACTURER. GUARANTEE: THE ONE-YEAR GUARANTEE PERIOD SHALL NOT START UNTIL THE PROJECT IS FULLY COMPLETED AND THE CONTRACTOR HAS RECEIVED THE FINAL PAYMENT AND CERTIFICATION OF COMPLETION. ALL EQUIPMENT AND ALL WORK SHALL BE FULLY GUARANTEED, PARTS AND LABOR, FOR ONE YEAR FROM THE DATE OF THE CERTIFICATE OF COMPLETION. REPAIRS MADE DURING THIS PEROID MUST BE FULLY GUARANTEED FOR AN ADDITIONAL ONE YEAR PERIOD FROM THE DATE OF REPAIRS. IN ADDITION, THE CONTRACTOR SHALL ASSUME FULL RESPONSIBILITY FOR ANY DAMAGE TO THE BUILDING, AND ITS CONTENTS OR OTHER EQUIPMENT, CAUSED BY DEFECTS OR IMPROPER INSTALLATION OF EQUIPMENT OR MATERIAL INSTALLED. SUBSTITUTIONS: CONTRACTOR 'SHALL PAY FOR ANY AND ALL ADDED COSTS ASSOCIATED WITH ANY SUBSTITUTION, INCLUDING SUBSTITUTIONS THAT REQUIRE CHANGES TO THE OTHER BUILDING COMPONENTS, SUCH AS ELECTRICAL, STRUCTURAL REINFORCING, CEILINGS, WALLS, ROOFS, ETC. THIS WILL INCLUDE ANY ENGINEERING/ARCHITECTURAL RE -DESIGN COSTS AS A RESULT OF SAID SUBSTITUTION. THESE COSTS SHALL NOT BE BORNE BY THE OWNER, ARCHITECT, NOR ENGINEER, REGARDLESS OF ACCEPTABILITY OF SUBSTITUTION. ENGINEER RESERVES THE RIGHT TO ACCEPT OR DENY ANY SUBSTITUTION THAT HE DOES NOT DEEM TO BE EQUIVALENT, AND CONTRACTOR SHALL PROVIDE SPECIFIED OR EQUIVALENT MATERIALS/EQUIPMENT AT NO ADDITIONAL COST TO OWNER, SHOULD A SUBSTITUTION BE DENIED. PLUMBING LEGEND DESCRIPTION ABBREV. SYMBOL SANITARY PIPING SAN GREASE PIPING GR GR VENT PIPING V DOMESTIC COLD WATER CW --------- DOMESTIC HOT WATER HW ---------- GAS PIPING GAS --w---�—�- BALL/ISOLATION VALVE BV -----lei--- DUAL-CHECK BACKFLOW PREVENTER GRADE CLEAN OUT COTG COTG WALL CLEAN OUT WCO WCO I FLOOR CLEAN OUT FCO FCO PIPE TURNING UP 0------- PIPE TURNING DOWN ------ CAPPED PIPING TYPICALITEM TYP CONNECTION BETWEEN NEW & EXISTING EXISTING (E) NEW (N) BALANCE VALVE BV NOTE ON EXISTING UTILITIES: CONTRACTOR SHALL FIELD VERIFY LOCATIONS & INVERTS OF ALL EXISTING UTILITY MAINS INSIDE BUILDING (I.E. SEWER, GAS, DOMESTIC WATER, ETC.) PRIOR TO ANY DEMOLITION OR CONSTRUCTION. ADVISE ENGINEER OF ANY DISCREPANCIES BEFORE PROCEEDING ANY FURTHER. ** CCTV VIDEO CAMERA INVESTIGATION REQUIRED BY PLUMBER (PRIOR TO ANY WORK) TO VERIFY INVERT ADEQUATE AT MOST REMOTE AREA OF NEW SANITARY UNDERGROUND CONNECTION. NOTIFY ENGINEER OF RESULTS OF CAMERA WORK. NOTE TO CONTRACTOR ON EXISTING CONDITIONS: 1 CONTRACTOR SHALL VISIT THE SITE PRIOR TO BID AND SURVEY ALL EXISTING CONDITIONS AND EQUIPMENT PRIOR TO SUBMITTING BID FOR WORK REQUIRED BY THESE DOCUMENTS. THIS INCLUDES ABOVE THE CEILING AND ON TOP OF THE ROOF. 2. CONTRACTOR SHALL REFER TO AND READ THROUGH ALL OF THE "CONTRACTOR'S SCOPE OF WORK" AS DEFINED IN THE BID SPECIFICATIONS AND DOCUMENTS AS PART OF THE BID PROCESS. 3. IF AT ANY TIME, THERE IS DISCREPANCY BETWEEN THE PLANS & SPECS. OR CONFUSION/CONCERN OVER REQUIRED WORK, CONTRACTOR SHALL IMMEDIATELY NOTIFY ARCHITECT. ENGINEER, &/OR OWNER AND GET DIRECTION BEFORE PROCEEDING WITH WORK IN I#l1j*v `•l.e 4. FOR ALL NEW ROOF PENETRATIONS, CONTRACTOR SHALL INCLUDE IN HIS BID THE COST TO HIRE THE ROOFING FIRM HOLDING THE WARRANTY TO PROVIDE ROOF PENETRATIONS. 5. FOR ALL EXISTING EQUIPMENT TO BE RE -LOCATED &/OR RE -USED, CONTRACTOR SHALL BE RESPONSIBLE FOR DISCONNECTION, SAFE STORAGE, & RE -CONNECTION OF SAID EQUIPMENT COMPLETELY. 6. FOR ALL EXISTING EQUIPMENT TO BE DEMOLISHED (I.E. DEMO) CONTRACTOR SHALL BE RESPONSIBLE FOR DISCONNECTION, REMOVAL, & DISPOSAL OFF -SITE PER CODE, OF SAID EQUIPMENT COMPLETELY. CIYIIII /� M 0) V 0 � � ao I 0 F_ t N Q V) U O 3 M w Y V) Yd o V) J W i� Z< Wa�� M aVi CL Q W U M /uj w Z � J � y J w Q u- �9 a� o L r j A a a a R >> R E Vl 4 r y +' O N O O (4-- 0z (� Q tl) z W < a (a a (.) o O v Q < to O � Z -p Lo (� a_ LIA N e� � W ti O q r~ Al Nu 56189 °. MATE OF s' TONAL Date: 4. 25.22 Checked by: mil Drawn: TJ/KB .lob: 21-042 Sheet POO 1 FIXTURE & CONNECTION SCHEDULE BRANCH SIZE FIXTURE TAG MANUFACTURER/MODEL REMARKS DRAINAGE WATER WASTE VENT COLD HOT LAVATORY LAV-1 2" 2" 1/2" 1 /2" AMERICAN STANDARD LUCERNE #0355.012 LAVATORY: 20"x18", VITREOUS CHINA, WITH FAUCET LEDGE AND INTEGRAL (ADA) DELTA SINGLE LEVER FAUCET #523LF—HGMHDF OVERFLOW. PROVIDE ARM CHAIR FLOOR CARRIER. SINGLE LEVER FAUCET MIXING VALVE: LAWLER # TMM-1070 WITH 4" CENTERS, 0.5—GPM AERATOR, &GRID DRAIN ASSEMBLY. PROVIDE ASSE 1070 LISTED MIXING VALVE SET TO 109'F, TAILPIECE, P—TRAP, SUPPLY CARRIER: ZURN Z1231 # & STOPS. INSULATE EXPOSED PIPING WITH TRUEBRO LAV GUARD KIT. TANKLESS TWH-1 -- -- 1/2" 1/2" EEMAX # EMT1 MINI —TANK WATER HEATER, 1.6—GALLONS, UL—LISTED, ELECTRONIC, WATER HEATER WATTS # LFMMV WALL MOUNT, 1.44—KW ® 120—VOLT. PROVIDE ASSE 1017 & 1070 MIXING VALVE SET TO 1097. ICE BOX IB-1 -- -- 1 /2" -- GUY GRAY # BIM875 ICE MAKER BOX: GALVANIZED STEEL BOX, 20 GA., 18 GA. FACEPLATE, (# BIM876 FOR CPVC) 1/4—TURN STOP, COMBINATION MIP OR SWEAT CONNECTION. PROVIDE ADDITIONAL CHECK VALVE & WATER HAMMER ARRESTOR. FLOOR DRAIN FD-1 3" 2" -- -- ZURN # Z415B DURA—COATED CAST IRON BODY, 6" DIAMETER BRONZE ADJUSTABLE STRAINER. ZURN # Z1072 PROVIDE 4" DEEP TRAP AND BARRIER —TYPE TRAP PROTECTION (ASSE 1072). FLOOR SINK FS-1 3" 2" -- -- ZURN # Z-1900-3 SANI—FLOOR RECEPTOR 12"x12%6" DEEP CAST IRON BODY AND SECURED 3/4—GRATE WITH WHITE WITH GRATE 3 4 / ACID RESISTING PORCELAIN ENAMEL INTERIOR AND TOP. COMPLETE WITH ALUMINUM ANTI —SPLASH INTERIOR BOTTOM DOME STRAINER. THERMAL MIXING TMX-1 -- -- 3/8" 3/8" WATTS # LFUSG—B MIXING VALVE: PROVIDE AT EACH HAND SINK AN IN —LINE MIXING VALVE, VALVE ASSE 1070 APPROVED, SET AT 109-F IN THE HW SUPPLY TO FIXTURE. FLOOR CLEANOUT FCO SEE -- -- -- ZURN # Z1400—BZ "LEVEL—TROL" ADJUSTABLE FLOOR CLEANOUT, DURA—COATED PLAN CAST—IRON, POLISHED BRONZE TOP, ADJUSTABLE TO FLOOR FINISH. WALL CLEANOUT WCO SEE -- -- -- ZURN # Z1468 WALL CLEANOUT — ROUND STAINLESS STEEL WALL ACCESS COVER PLAN WITH SECURING SCREW AND BRONZE RAISED HEX HEAD PLUG. GOTG " GREASE TRAP SIZING RESTAURANTS SEATS = 85 DINING SEATS GALLONS OF WASTE PER SEAT = 25 GALLONS (10—SINGLE SERVICE; 25—DISHMACHINE/CHINA) HOUR OF OPERATION = 8 HOURS / 12 LOADING FACTOR = 1.0 OTHER HIGHWAY 85 X 25 X 8/12 X 1.0 = 1,417—GALLONS (1) 1,500—GALLON GREASE INTERCEPTOR EXISTING SIZING BASED ON FL.ADMIN.CODE RULE#64E-6, PER FBC—PLBG, 1003.3.4, EXCEPTION, USING AN OUTDOOR GREASE INTERCEPTOR. TOTAL DRAINAGE FIXTURE UNITS PER FBC—P TABLE 709.1 — 10.0 DFU � ► !r.vwm Lziej n (E)1 —1 /2"GAS I EXISTING GAS TANKLESS WATER HEATER (199—MBH) FCD �1 EXISTING GAS F'p, METER TO REMAIN RANGE 1 88—MBH I t� I `/EXISTING GAS COCK / & ANSUL VALVE 1 "GAS <op'/ (E)1 —1 /2"GASH.' \® MANIFOLD 36" GRIDDLE 120—MBH 60" GRIDDLE 120—MBH I � FRYER r 10s—MBH FRYER (E)DIRT LEG 105—MBH GAS PIPING SIZED BASED ON 804—MBH ® 1/2—PSI DELIVERY AND TOTAL EQUIVALENT PIPING LENGTH OF 50—FT MAX. (SEVENTH ED. FLORIDA FUEL GAS CODE TABLE 402.4(2)) -i�®1�� �-4 1 p CONNECT TO J (E)3/4"CW ABOVE RESTROOM _ r'� �(E)3/4"HW TO /2e (E)KITCHEN 1 C� EQUIPMENT 1, EXISTING GAS TANKLESS WATER HEATER (199—MBH) TO REMAIN i SEE FIXTURE SCHEDULE FOR BRANCH SIZES TO FIXTURES TOTAL WATER FIXTURE UNITS PER FBC—P TABLE E103.3(2) — 12.9 WFU �_(E)3/4"CW WATER ISOMETRIC RISER avG LLB NONC WALL —SEE FLOOR PLANS SUPPLY PIPE —SEE PLUMB BLOCKING BETWEEN STUDS PIPE TO EQUIP. FIXTURE SILICON CAULK—FSE AREAS QUARTER —TURN ANGLE STOP (TYP) CHROME TRIM ELBOW W/ANCHOR FLANGE FIXTURE SHUT- OFF VALVE NOT TO SCALE MAY EXTEND AS A WASTE OR VENT. REFER TO PLANS. —\ CHROME WALLCOVER & SCREW .......... .. a..t BALANCE OF PIPING SAME AS CLEANOUT TO GRADE - WALL PLUGGED TEE W/CLEANOUT FLOOR LINE GRADE OR PAVING CLEANOUT ASSEMBLY SAME SIZE AS SEWER UP TO 8" DIA. SEWER MATERIAL AND SIZE AS SPECIFIED COVER FOR DUTY REQUIRED a > 6" THICK CONCRETE BEND OR COMBINATION LONG SWEEP 1/4 "Y" AND 1 /8 BEND 2- WAY GRADE CLEANOUT DEV& (COTG) SCALE: NONE CLEANOUT & ACCESS COVER TO BE FLUSH W/TOP OF FLOOR FLOOR LINE c q BALANCE OF PIPING SAME AS CLEANOUT TO GRADE - FLOOR CLEANOUT (F.C.O.) 1 /8" BEND NOT TO SCALE C.O. NOT TO BE LOCATED IN CARPETED AREA, WALL CLEANOUT NOT TO SCALE CAST B/ TILE, 1 / SLOPE N LATICRE' WATERPf MEMBRA 119fiffl(1 DRAIN A COLLAR FLOOR FLOOR DRAIN WITH TRAP GUARD DETAIL SCALE: NONE TILE, SLOPE 1 /4"/FT. - WATERPROOF MEMBRANE CAST IRON 3/4 GRATE DOME STRAINER CLAMP RING CONC. FOR SINK SIZE AND TYPE, SEE PLUMBING FIXTURE SCHEDULE AND SPEC. FLOOR SAC DETAIL SCALE: NONE TDAD 011ADn INSERT ;ERTIFIED) M00 0) N cn o - LAJ N N J < J Y V Li W (f) o I o a ZQ w-,;;M0 a Q Q W U M.41 vi Lij Z��N J cNv3a� � w 10 0 L Q N C�_o Q � N m 12 C 0 10 k c �- 3 � N Q @ E a _ d n. 4-% a¢ d Q AO — R/ C� Z Q O W —► < Ca t0 0 cv_ 0 (-- � << J lti L O L 0z Z -i- pCo- i- ao W N t4 I" f'-W u D �GF NS lLi'. Nc 5ta1}3y * * G. IATf 0 Date: 4. 25. 22 Checked by: NIL Drawn: T.1/KB Job: 21-012 Sbccl P002 IL EXISTING WATER - CLOSET TO REMAIN EXISTING LAV TO BE — DEMOLISHED AND CAP ALL PIPING BELOW SLAB OR ABOVE CEILING r-� EXISTING GAS METER TO REMAIN L_J I I r I I I I EXISTING GAS TANKLESS WATER HEATER TO REMAIN EXISTING DRINKING FOUNTAIN TO BE DEMOLISHED AND CAP r -- -- ALL PIPING BELOW SLAB OR ABOVE CEILING I I EXISTING SINK TO EXISTING GAS EQUIPMENT TO BE BE DEMOLISHED ANDD CAP A r - ALL PIPING IN WALL DEMOLISHED. GAS MANIFOLD TO REMAIN. CAP ALL OTHER PLUMBING i PIPING BELOW SLAB OR IN WALL d - J EXISTING PLUMBING FIXTURES IN THIS AREA TO REMAIN DEMO FLOOR PLAN BL.i S i; TABLE I? ire wjzwi .gyp. I I BUJ I 1 LLBcool Ef ':. r .... t I i EXISTING RESTROOMS L..........._ .- TO REMAIN lj. '-- EXISTING PLUMBING TO BE DEMOLISHED AND CAP ALL PIPING BELOW SLAB OR ABOVE CEILING EXISTING BUSS S I,A ill _ . _. ... _. _. .. _ .. r. T ..._. _....... _ .. Mi it Id it U) o Z N O v r_n w t� z V I V / M n O � co LIJlal N (D � H I._L j Q In (n � U J _j p Q M 3 00 � Y V) N Z Q warn a } W Z � W � U W V 0 N3aw w 6 l9 � g l0 is � a � O e M O N n c n 8 ti Q ,n N =, �F r r�+ cv— Q ? -) V / O li c)O 1J < v O N BC f� 4 L!-I Q � N w "` ;L� x\ LENS No 56169 STATE { SOH 11111 tile Date: 4. 25. 22 Checked by: ML Drawn: J 11l: 21-042 p 10 0 c (E)1500—GALLON GREASE INTERCEPTOR (FIELD VERIFY SIZE) (E)COTG COTG GR 0 (E)4"GIR � 0 PLUMBING SANITARY PLAN I � I ; I GR TOILET LAV- 1 wco D15H WASHING ATTIC 1(),- OFFICE I i KITCHEN GR GR \0 10 54 FS-1 � FCO FD 1 G,)p FS-1 IF S - I .4 SERVING + KITCHEN 7_ ....... .. ........ ..... [A! J, u ,,41:11 J TOILET TOILET HALL 112 . .... ..... . .. ....... .... ........ .. it 0 DMG < 102 T. .. .... . A, ...... .... ........ ... ....... . .... . .. .... ....... ........... . .. . ....... . .. .. .. . . ....... . ...... .. j DINING 101 N 'j . ... .. ......... . . ATTIC ACCESS _J, a L----- — OFFICE .. ... . ..... . .... ..... ------ Lj ////—EXISTING 3/4"CW FROM METER m CD I KITCHEN < Ln C-1 TOILET FMX 1 10 14 FLA V TWH I EXISTING GAS GAS GAS GAS GAS — GAS GAS 4 CONNECT NEW GAS TO METER TO REMAIN T_ -A EXISTING 1-1-2"MANIFOLD Ll ----- ----- CONNECT TO CW AT OLD DEMISING WALL EXISTING GAS AND RE—ROUTE TO WALL & UP IN WALL OVER CEILING, THEN DOWN TO TANKLESS WATER 590 HEATER (199--MBH) ALT. ROUTE BELOW PASS THRU IF TO REMAIN CONCEALED BEHIND FIXTURES. KITCHEN bi T_ LLJ :r SERVING T_ 0� T_ _j j ft� W OD LU M /CAUiIER "o m ck� ch Ll- LL- 10 Ln U) CD 0 I J`J 2 2 co 4_7 EXISTING 1-1/2"GAS, GAS COCK, ANSUL IL t VALVE,1-1-2"MANIFOLD TO REMAIN Of c T 59 OILET TOILETff PLUMBING WATE 10 AND GAS PLAN HALL F @ @ a 9 r1j, R w 11 c F E 9 DLSCHIPTION I IAND '-,INI<, WITI 1 ',11 A'd 11 S m F N T Y GAS c N E 9 MK. QTY I WATER WAS IE REMARKS c� i 0 0 U Li CL 1112" j 112" 1-1/2' SEE HOOD DRAWING 10 11 1 PREP IABLL WIIIH ;INK 112" 2 1 EXHAUST HOOD FIRE SUPPRESSION SYSTEM--- RANGE, M[_F)IUM DUTY GAS3 14 1 4 T 155 15 1 SEE HOOD DRAWINC 21 1 HOT FOOD TABLE, GAS 30 1 EXHAUST HOOD —FIRE SUPPRESSION SYSTEM 33 1 35 1 FRYER, DEEP FA I', GAS—FIRL.D FRYER, DEEP FAI, GAS-- FIRED V81. 3/4" 3/4" 1019 105 36 ,E9 1 1 GRIDDLE 60, GAS COUNTERTOP 3/4" 3/4" 120 120 40 54 1 1 GRIDDLE 36", GAS COUNTERTOP WATER FROM FILIER ICE BIN 3/4" 55 1 1 C I - CU 13 E R 8' 55 A 1 WATER TREATMENT UNIT - 59 1 I 1 k REFRIGERATOR, U/COUNTER' 2—'_1�()1 ( 1 TFA BREWER I PFF`JANDINGJCF BIN W/SODA TOWS RL LL(,[N[) WITH EXISTING EQUIPMENT. 1_EG'FNF) WITH NEW CUT SHEEI-S., 112" 61L NOTES: 1. VERIFY 2. VERIFY r DINING .... . ........... k .... . ....... ... . .... . T.. . ..... ... . . ...... .. �i ... .... ... ..... .. _4 .... ...... . .... ... . .. .. ......... DINING F U) 0 U) Lu LL L) - U) V) 00 LO �? 1-? cy) co uj 'cj (�s Lo Ld < V) 7i >__to < 3 00 __j LL_ W U- IN 11 T cp w 0 _I La — rn 00 a < < > (r) _j X: LA --A < _j V) Lo U) CIO LJ W N 3'L w LLJ IT I co LL_ rn E L and' .0 > aim gar => > < io 19 E E (L x D 0 < - > < Z < VI J cv cQ cv- Q,) 0 < LL_ z: (V ca t'%;J1 111141, 1 \A ....... No 56189 7-n E (0) 0 `tf, /CON 11,11, I)ate: 4.25.22 Checked by: N1 1, I)rawn: 'lot): 2 1 _0 12 sheet P101 IL 0 MECHANICAL SPECIFICATIONS SCOPE: THE CONTRACTOR SHALL VISIT THE SITE AND EXAMINE THE DRAWINGS AND SPECIFICATIONS BEFORE SUBMITTING A PROPOSAL. ALL WORK SHALL BE IN ACCORDANCE WITH THE FLORIDA BUILDING CODES SEVENTH EDITION (2020), WITH ALL AMENDMENTS, AND LOCAL CODES AND ORDINANCES. INSTALLATION SHALL COMPLY WITH THE CODE REFERENCED STANDARDS SET BY NFPA, ASHRAE, ASPE, SMACNA, NEC AND UL. THE SYSTEMS, EQUIPMENT, DEVICES AND ACCESSORIES SHALL BE INSTALLED, FINISHED, TESTED AND ADJUSTED FOR CONTINUOUS AND PROPER OPERATION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR HIS WORK FITTING IN PLACE AND SHALL COORDINATE WITH OTHER TRADES TO AVOID INTERFERENCE WITH THEIR WORK. THE INFORMATION GIVEN HEREIN AND ON THE DRAWINGS IS AS EXACT AS COULD BE SECURED, BUT ITS EXTREME ACCURACY IS NOT GUARANTEED. THE DRAWINGS ARE DIAGRAMMATIC, INTENDED TO SHOW GENERAL ARRANGEMENT, CAPACITY AND LOCATION OF VARIOUS COMPONENTS, EQUIPMENTS, AND DEVICES. IF WORK IS REQUIRED IN A MANNER TO MAKE IT IMPOSSIBLE TO PRODUCE FIRST CLASS WORK, OR SHOULD DISCREPANCIES APPEAR AMONG THE CONTRACT DOCUMENTS, OR BETWEEN THE CONTRACT DOCUMENTS AND THE MANUFACTURER'S RECOMMENDATIONS,THE CONTRACTOR SHALL REQUEST INTERPRETATION BEFORE PROCEEDING WITH WORK. CONTRACTOR SHALL FURNISH AND INSTALL ALL MINOR ITEMS WHICH ARE OBVIOUSLY AND REASONABLY NECESSARY TO COMPLETE THE INSTALLATION WHETHER OR NOT SPECIFIED IN THE DOCUMENTS. REQUIRED COORDINATION: ALL WORK SHALL BE COORDINATED WITH ALL TRADES INVOLVED. OFFSETS IN DUCTS AND PIPING (INCLUDING DIVIDED DUCTS) AND TRANSITIONS AROUND OBSTRUCTIONS SHALL BE PROVIDED AT NO ADDITIONAL COST TO THE OWNER. CONSTRUCTION PLANS: IN GENERAL, PLANS AND DIAGRAMS ARE SCHEMATIC ONLY AND SHOULD NOT BE SCALED. REQUIRED ACCESS: CONTRACTOR SHALL ENSURE THAT ALL EQUIPMENT AND DEVICES THAT REQUIRE REPLACEMENT, SERVICING, ADJUSTING OR MAINTENANCE SHALL BE LOCATED TO ALLOW EASY ACCESS AND SPACE FOR REMOVAL OF INTERNAL ASSEMBLIES, IF REQUIRED. CONTRACTOR SHALL PROVIDE ACCESS PANELS WHERE REQUIRED TO ALLOW ACCESS, EVEN IF NOT INDICATED ON 'THE DRAWINGS AT NO ADDITIONAL COST TO OWNER. WIND RESISTANCE: ALL EQUIPMENT, APPLIANCE AND SUPPORTS LOCATED EXTERIOR OF THE FACILITY SHALL BE INSTALLED TO RESIST WIND LOADS AS DETAILED IN THE BUILDING CODE. CUTTING AND PATCHING: ALL OPENINGS AROUND DUCT OR PIPE PENETRATIONS THROUGH SMOKE OR FIRE RATED FLOORS, CEILINGS OR WALLS SHALL BE SEALED AIRTIGHT WITH MATERIALS HAVING A RATING EQUAL TO THE MATERIAL OF THE WALL, CEILING OR FLOOR PENETRATED. EQUIPMENT TAGS: ALL EQUIPMENT WILL HAVE A PERMANENTLY FIXED ENGRAVED PHENOLIC LABEL CORRESPONDING TO THE EQUIPMENT TAG ON THE ENGINEER'S DRAWINGS. FIRESTOPPING: UL APPROVED MATERIALS AND METHODS SHALL PROTECT THE PENETRATIONS OF FIRE AND/OR SMOKE RATED WALLS, CEILINGS OR FLOORS. THE RATING OF THE FIRESTOPPING SHALL EQUAL THE RATING OF THE RATED ASSEMBLY. ALL INSULATION SHALL HAVE COMPOSITE FIRE AND SMOKE HAZARD RATINGS AS TESTED BY PROCEDURE ASTM E-84, NFPA-225, UL-723 NOT EXCEEDING: FLAME SPREAD 25 SMOKE DEVELOPED 50 FUEL DISTRIBUTED 50 ACCESSORIES SUCH AS ADHESIVE, MASTIC, CEMENTS AND TAPES SHALL HAVE THE SAME COMPONENT RATING AS LISTED ABOVE. START-UP: CONTRACTOR SHALL STARTUP ALL EQUIPMENT AND FOLLOW THE MANUFACTURER'S START-UP PROCEDURES. OPERATING AND MAINTENANCE DATA: SUBMIT THREE COPIES OF MANUFACTURER'S OPERATING AND MAINTENANCE INSTRUCTIONS AND SPARE PARTS LIST FOR EACH PIECE OF EQUIPMENT. CONDENSATE DRAIN PIPING: CONDENSATE DRAIN PIPING SHALL BE PVC TYPE DWV. DRAINS SHALL BE PITCHED NOT LESS THAN 1 PERCENT. RUNS SHALL BE AS SHORT AS POSSIBLE WITHOUT ANY DIPS TO TRAP WATER AND INTERFERE WITH PROPER DRAINAGE. PROVIDE TRAPS AND CLEANOUTS AT DRAIN PAN CONNECTIONS. RUN CONDENSATE DRAIN PER PLANS. INSULATE CONDENSATE LINE INSIDE BUILDINGS WITH 1" ARMAFLEX (ASTM E-84). DIMENSIONAL DATA: ALL DUCTWORK DIMENSIONS SHOWN ON DRAWINGS ARE CLEAR INSIDE DIMENSIONS. SUPPLEMENTARY SUPPORTS: CONTRACTOR SHALL PROVIDE ALL SUPPLEMENTARY STEEL REQUIRED TO SUSPEND MECHANICAL EQUIPMENT AND MATERIALS, IN ORDER TO PROVIDE A "VIBRATION -FREE" RIGID INSTALLATION. DUCTWORK - GENERAL: FABRICATE AND INSTALL ALL DUCTWORK AND DUCT ACCESSORIES IN ACCORDANCE WITH THE LATEST EDITION OF APPLICABLE SMACNA STANDARDS, THE LATEST NFPA STANDARDS, AND THIS SPECIFICATION. THE MOST STRINGENT OF THESE SHALL BE THE MINIMUM STANDARD. MINIMUM OF 1" PRESSURE CLASS RATING FOR ALL DUCTWORK. ALL RECTANGULAR SUPPLY AND RETURN DUCTWORK TO BE R-6.0 RIGID FIBERGLASS DUCTSOARD (UL-181 AND 181A) WITH CLEANABLE AIRSIDE SURFACE AND EPA -APPROVED BIOCIDE (ANTI -MICROBIAL AGENT) IMPREGNATED IN MATTED AIR -SIDE SURFACE. KITCHEN HOOD GREASE EXHAUST DUCTWORK SHALL BE PREFABRICAGTED DOUBLE -WALL ROUND STAINLESS STEEL DUCTWORK. OPTION FOR KITCHEN GREASE DUCT IS 16-GAUGE BLACK STEEL, WELDED LIQUIDTIGHT PER NFPA-96, AND INSULATED WITH 2-HOUR LISTED FIRE BARRIER TO MAINTAIN ZERO CLEARANCES TO COMBUSTIBLES AND LIMITED COMBUSTIBLES. ALL RESTROOM EXHAUST DUCTWORK SHALL BE GALVANIZED SHEET METAL STEEL OF LOCKFORMING GRADE CONFORMING TO ASTM A653 AND ASTM A924. DUCTWORK INSTALLATION: ALL INTERIOR DUCTWORK SHALL BE SEALED TO SMACNA CLASS (B) REQUIREMENTS WITH UL-181 MASTIC. PROVIDE DOUBLE THICKNESS TURNING VANES IN ALL NINETY (90) DEGREE SQUARE ELBOWS. CONTRACTOR SHALL FURNISH AND INSTALL ALL DUCT OFFSETS AS REQUIRED TO CLEAR INTERFERENCES WITH EXISTING BUILDING STRUCTURE, PIPES AND ELECTRICAL CONDUITS. FURNISH AND INSTALL ALL MISCELLANEOUS STEEL SUPPORTS REQUIRED FOR HANGING AND SUPPORTING DUCTWORK UNLESS OTHERWISE NOTED. VOLUME DAMPERS: DAMPERS SHALL BE PROVIDED IN THE BRANCHES OF THE DUCT SYSTEMS WHERE SHOWN ON DRAWINGS AND AS REQUIRED TO PROPERLY REGULATE THE VOLUME OF AIR DELIVERED TO OR WITHDRAWN FROM THE OUTLETS. FLEXIBLE DUCTWORK: FLEXIBLE DUCTWORK MAY BE USED FOR THE FINAL RUNOUTS TO AIR OUTLETS, AND SHALL BE SIZED TO MATCH AIR OUTLET NECK. FLEXIBLE DUCTS SHALL NOT EXCEED 8-FEET LENGTHS. NO FLEXIBLE DUCTS SHALL PENETRATE FIRE -RATED WALLS OR CEILINGS. FLEXIBLE DUCTS SHALL COMPLY WITH THE PROVISIONS OF UL-181 CLASS 1 AIR DUCT MATERIAL. DUCTS SHALL BE FACTORY MADE AND COMPOSED OF: AN INNER FIBERGLASS WOVEN LINER, ENCAPSULATED HELIX COIL, A FIBERGLASS INSULATING BLANKET AND OUTER VAPOR BARRIER OF FIBERGLAS REINFORCED METALIZED FILM LAMINATE. PROVIDE THERMAFLEX MK-C FLEXIBLE DUCT OR APPROVED EQUAL (MIN. OF R-6.0). CARE IS TO BE TAKEN THAT ALL RUNOUTS OF FLEXIBLE DUCTS ARE INSTALLED AS STRAIGHT AS PRACTICAL AND FASTENED SO AS TO ELIMINATE AIR LEAKAGE. THE INSTALLATION SHALL CONFORM TO THE TECHNIQUES SHOWN IN THE UL APPROVED AND FACTORY -SUPPLIED INSTRUCTIONS. INSULATION: ASSURE ALL DUCTWORK IS SEALED PRIOR TO INSTALLING INSULATION. ALL METAL SUPPLY, RETURN, AND FRESH AIR (OUTSIDE AIR) DUCTWORK SHALL BE WRAPPED WITH 2" THICK FIBERGLASS BLANKET INSULATION WITH FSK (ASJ) FACING, MINIMUM INSTALLED R VALUE OF 6.0, AND FLAME SPREAD/SMOKE DEVELOPED RATINGS OF 25/50 BY ASTM E-84. INSTALL INSULATION ON DUCTWORK USING ADHESIVE AND/OR WELD PINS WITH WASHERS. SEAL ALL INSULATION JOINTS, SEAMS AND FASTENER PIN PENETRATIONS WITH VAPOR RETARDING PRESSURE SENSITIVE TAPE OR WITH GLASS FABRIC AND MASTIC. INSTALL TAPERED INSULATION TO THE TOP OF ALL EXTERIOR HORIZONTAL RECTANGULAR DUCTS WIDER THAN 24" BEFORE APPLYING THE FINISH INSULATION TO CAUSE A 1 /2" PER FOOT SLOPE OF FINISH INSULATION TO SHED WATER. BRANCH DUCT RUNOUTS: SHALL BE GALVANIZED ROUND (SNAPLOCK) SEAM LOCKED DUCTWORK WITH EXTERNAL FIBERGLASS WRAP INSULATION (R-6.0). NOTE: BRANCH DUCT RUNOUTS & FLEXIBLE DUCTS SHALL BE THE SAME SIZE DUCT AS THE DIFFUSER NECK CONNECTED TO, AS LISTED ON THE FLOOR PLAN. GRILLES AND DIFFUSERS: ALL GRILLES AND DIFFUSERS SHALL BE INSTALLED WITH AN INSULATED BOOT OR BLANKET. PROVIDED A METHOD OF VOLUME CONTROL BY DEVICE ADJUSTABLE AT DIFFUSER FACE OR MANUAL VOLUME DAMPERS AT TAKEOFF BRANCHES. COORDINATE DIFFUSER AND GRILLE LOCATIONS WITH ELECTRICAL LIGHTING LAYOUT AND ARCHITECTURAL REFLECTED CEILING PLAN. DUCT SMOKE DETECTORS: INSTALL SMOKE DETECTORS AS RECOMMENDED BY MANUFACTURER TO ACQUIRE PROPER READINGS. LOCATION OF DUCT MOUNTED SMOKE DETECTORS ARE FOR REFERENCE LOCATION ONLY. FINAL PLACEMENT SHALL MEET ALL REQUIREMENTS IN THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. PROVIDE 12"X12" ACCESS DOOR FOR INSPECTION AND SERVICE. SMOKE DETECTORS SHALL BE FURNISHED & WIRED BY FIRE ALARM INSTALLER AND INSTALLED BY HVAC CONTRACTOR. SMOKE DETECTORS SHALL BE WIRED TO SHUTOFF UNIT WITH THE DETECTION OF SMOKE. CONTROLS: PROVIDE CONTROLS COMPLETE TO SUIT THE EQUIPMENT PROVIDED AND TO ACCOMPLISH THE SEQUENCE OF OPERATION AS REQUIRED BY PLANS AND SYSTEMS. LOCATE THERMOSTATS 48" ABOVE FINISHED FLOOR, UNLESS OTHERWISE NOTED. THERMOSTATIC CONTROLS SHALL BE PROGRAMMABLE TO INCLUDE ALL ITEMS REQUIRED BY FBC-ENERGY CODE SIXTH EDITION AND SHALL HAVE LOCKOUT FUNCTION WITH PASSWORD. MINIMUM FUNCTIONALITY SHALL INCLUDE: 7-DAY A WEEK PROGRAMMABLE CONTROLLER WITH SETBACKS UP TO 85-F AND DOWN TO 55-F, 10-HOUR BATTERY BACKUP, MANUAL OVERRIDE FOR 2-HOURS, AND AUTOMATIC STARTING (OPTIMUM START) ADJUSTABLE DAILY START TIMES. TESTING AND BALANCING: THE CONTRACTOR SHALL ENSURE THAT ALL DEVICES AND SYSTEMS ARE COMPLETE, TESTED AND BALANCED, AND READY FOR OPERATION WHEN THE FACILITY IS HANDED OVER THE OWNER. THE AIR CONDITIONING SYSTEM SHALL BE TESTED IN ACCORDANCE WITH CURRENT AABC OR NEBB OR NBC PROCEDURES. A CERTIFIED, WRITTEN REPORT SHALL BE SUBMITTED TO MECHANICAL ENGINEER FOR APPROVAL. THE CONTRACTOR SHALL RECTIFY DISCREPANCIES BETWEEN THE ACTUAL INSTALLATION AND CONTRACT DOCUMENTS WHEN IN THE OPINION OF THE T&B AGENCY OR THE ENGINEER, THAT THE DISCREPANCIES WILL AFFECT SYSTEM BALANCE AND PERFORMANCE. SUBMITTALS REQUIRED: SUBMIT SHOP DRAWINGS FOR ALL MATERIALS, EQUIPMENT, AND SYSTEMS REQUIRED BY THESE DOCUMENTS (SEE ARCH. PLANS/SPECS FOR SPECIFIC FORMATTING), INCLUDING: ROOFTOP UNIT TEST/BALANCE REPORT EXHAUST FANS DIFFUSERS AND GRILLES DUCTWORK, INSULATION AND ACCESSORIES (CONNECTIONS, MASTICS, ETC.) THERMOSTATS & CONTROLS SUBSTITUT10i4S: -CONTRACTOR SHALL PAY FOR ANY AND ALL ADDED COSTS ASSOCIATED WITH ANY SUBSTITUTION, INCLUDING SUBSTITUTIONS THAT REQUIRE CHANGES TO THE OTHER BUILDING COMPONENTS, SUCH AS ELECTRICAL, STRUCTURAL REINFORCING, CEILINGS, WALLS, ROOFS, ETC. THIS WILL INCLUDE ANY ENGINEERING/ARCHITECTURAL RE -DESIGN COSTS AS A RESULT OF SAID SUBSTITUTION. THESE COSTS SHALL NOT BE BORNE BY THE OWNER, ARCHITECT, NOR ENGINEER, REGARDLESS OF ACCEPTABILITY OF SUBSTITUTION. ENGINEER RESERVES THE RIGHT TO ACCEPT OR DENY ANY SUBSTITUTION THAT HE DOES NOT DEEM TO BE EQUIVALENT, AND CONTRACTOR SHALL PROVIDE SPECIFIED OR EQUIVALENT MATERIALS/EQUIPMENT AT NO ADDITION COST TO OWNER, SHOULD A SUBSTITUTION BE DENIED. GUARANTEE: THE ONE-YEAR GUARANTEE PERIOD SHALL NOT START UNTIL THE PROJECT IS FULLY COMPLETED AND THE CONTRACTOR HAS RECEIVED THE FINAL PAYMENT AND CERTIFICATION OF OCCUPANCY. ALL EQUIPMENT AND ALL WORK SHALL BE FULLY GUARANTEED, PARTS AND LABOR, FOR ONE YEAR FROM THE DATE OF THE CERTIFICATE OF COMPLETION. REPAIRS MADE DURING THIS PEROID MUST BE FULLY GUARANTEED FOR AN ADDITIONAL ONE YEAR PERIOD FROM THE DATE OF REPAIRS. IN ADDITION, THE �- CONTRACTOR SHALL ASSUME FULL RESPONSIBILITY FOR ANY DAMAGE TO THE BUILDING, AND ITS CONTENTS OR OTHER EQUIPMENT, CAUSED BY DEFECTS OR IMPROPER INSTALLATION OF EQUIPMENT OR MATERIAL INSTALLED. A 5-YEAR WARRANTY IS REQUIRED FOR COMPRESSORS. HVAC LEGEND ® SUPPLY AIR DIFFUSER OR GRILLE ® ® RETURN/EXH. AIR REGISTER OR GRILLE NEW DUCTWORK, WITH SIZE LISTED FLEXIBLE DUCT DUCT SMOKE DETECTOR --- FIRE DAMPER --� SMOKE/FIRE DAMPER CD CONDENSATE DRAIN RFT REFRIGERANT LINE SET QT THERMOSTAT BASE H@ HUMIDITY SENSOR FT REMOTE TEMPERATURE SENSOR CARBON DIOXIDE SENSOR C® CARBON MONOXIDE SENSOR GNITROGEN DIOXIDE SENSOR 9 HYDROGEN SENSOR 4+ AIRFLOW DIRECTION 'ld 1" DOOR UNDERCUT 0 1 ROUND, DIAMETER AFF I ABOVE FINISHED FLOOR CFM CUBIC FEET PER MINUTE TYP TYPICAL - ITEM OR METHOD BD BAROMETRIC DAMPER —p GRAVITY BACK -DRAFT DAMPER VD / l� MANUAL VOLUME DAMPER (W/HANDLE) MD @G) MOTORIZED DAMPER DOUBLE THICK VANES SUPPLY DUCT TAKE -OFF WITH VD SUPPLY DUCT TAKE -OFF WITH SCOOP SIDE DIFFUSER WITH VD (N) NEW (E) EXISTING ® SWITCH CONNECT NEW TO EXISTING ® WAVE GUIDE — CONDENSATE LINE ON ROOF SUPPORTS DIFFUSER TAG EQUIPMENT TAG /; AIRFLOW EQUIPMENT 400 CFM TYPE RTU-1 CQ-12 0 :EQUIPMENT MARK-/ -NECK NUMBER SIZE NOTE TO CONTRACTOR ON EXISTING CONDITIONS: 1. CONTRACTOR SHALL VISIT THE SITE PRIOR TO BID AND SURVEY ALL EXISTING CONDITIONS AND EQUIPMENT PRIOR TO SUBMITTING BID FOR WORK REQUIRED BY THESE DOCUMENTS. THIS INCLUDES ABOVE THE CEILING AND ON TOP OF THE ROOF. 2. CONTRACTOR SHALL REFER TO AND READ THROUGH ALL OF THE "CONTRACTOR'S SCOPE OF WORK" AS DEFINED IN THE BID SPECIFICATIONS AND DOCUMENTS AS PART OF THE BID PROCESS. I IF AT ANY TIME. THERE IS DISCREPANCY BETWEEN THE PLANS & SPECS. OR CONFUSION/CONCERN OVER REQUIRED WORK. CONTRACTOR SHALL IMMEDIATELY NOTIFY ARCHITECT. ENGINEER. &/OR OWNER AND GET DIRECTION BEFORE PROCEEDING WITH WORK IN QUESTION, 4. FOR ALL NEW ROOF PENETRATIONS, CONTRACTOR SHALL INCLUDE IN HIS BID THE COST TO HIRE THE ROOFING FIRM HOLDING THE WARRANTY TO PROVIDE ROOF PENETRATIONS. 5. FOR ALL EXISTING EQUIPMENT TO BE RE -LOCATED &/OR RE -USED, CONTRACTOR SHALL BE RESPONSIBLE FOR DISCONNECTION, SAFE STORAGE, & RE -CONNECTION OF SAID EQUIPMENT COMPLETELY. 6. FOR ALL EXISTING EQUIPMENT TO BE DEMOLISHED (I.E. DEMO) CONTRACTOR SHALL BE RESPONSIBLE FOR DISCONNECTION, REMOVAL, & DISPOSAL OFF -SITE PER CODE, OF SAID EQUIPMENT COMPLETELY. RTU CABINET BALANCING HOT GAS DAMPER REHEAT ELECTRIC MERV-7 (30%) COOLING COIL IF SUPPLY HEATING FILTER COIL SPECIFIED FAN COIL OUTSIDE AIR SEOUBCE OF O iAT10N 6100FfOP LINTS) A: SUPPLY FANS, THE EVAPORATOR FAN WILL RUN CONTINUOUSLY DURING OCCUPIED HOURS AND/OR IF KEF-2 IS RUNNING AND CYCLE ON/OFF WITH COOLING / HEATING /VENTILATION IN UN -OCCUPIED MODE AS PROGRAMMED AND SUBJECTED TO FIRE ALARM (DUCT SMOKE DETECTOR) SHUTDOWN. B: OUTSIDE AIR DAMPER, THE MOTORIZED DAMPER CLOSES WHEN THE UNIT IS OFF. DAMPER SHALL OPEN FULLY WHEN SUPPLY FAN STARTS. C: COOLING COIL, THE DX REFRIGERANT COIL AND COMPRESSORS SHALL ENERGIZE IN STAGES (IF APPLICABLE) TO MAINTAIN SPACE COOLING SETPOINT. (75-F OCCUPIED/ 80-F UNOCCUPIED) D: HEATING COIL (IF APPLICABLE), THE ELECTRIC HEAT WILL ENERGIZE IN STAGES TO MAINTAIN HEATING SETPOINT. (68-F OCCUPIED/60'1` UNOCCUPIED). E: HUMIDITY CONTROL, WHEN THE COOLING TEMPERATURE SETPOINT IS SATISFIED BUT THE HUMIDITY SETPOINT IS UNSATISFIED, THE UNIT SHALL GO INTO DEHUMIDIFICATION MODE, BY CLOSING THE FRESH AIR DAMPER AND ACTIVATING THE COMPRESSORS AND THE REHEAT COIL IN STAGES TO PREVENT OVERCOOLING UNTIL HUMIDITY SETPOINT IS SATISFIED. (50% OCCUPIED/60% UNOCCUPIED). F: EXHAUST FANS, RESTROOM FANS WILL START AND RUN FULL SPEED WHEN RESTROOM IS OCCUPIED AS DETERMINED BY THE INTERLOCKED LIGHT SWITCHES. THE BREAKROOM FAN SHALL START AND RUN FULL SPEED WHEN SWITCH IS ENGAGED AND RUN ON 10 MINUTE TIMER. DUCT SMOKE DETECTOR SD SUPPLY RETURN AIR AIR MANUAL BALANCE DAMPERS ADJUSTABLE SPACE SPACE MOUNT HUMIDITY SENSOR THERMOSTAT FM-# CONSTANT VOLUME CONTROL SCHEMATIC NO SCALE �1111111 MCO M V) V) LO ao ., o r- cp w Q Y ((n N � (/) w W o-1'�� a ZQ W�� CL. p w 0 LijZ nevi J in ••Z5 Q w Q a- ao 119 L Q � LL c E �j E a L V o. o > o.o " a Q �a E I .l a (L Q 0 Q >O � 0 6 WLL- � CL a/Q< J L o J I n C� col I � � N W ti AH a ,%ti"1 U 11111"I, �% �v_Vd D. ��i No 56189 �. STATE OF 0,< . • k Date: 4. 25. 22 Checked by: MI, Drawn: TJ/K13 Job: 21-042 Sheet moor ti LIl 55 D PACKAGED ROOF TOP UNIT SCHEDULE FOR EXISTING UNITS COOLING COOLING CAP HEATING CAP POWER MARK CFM 0/A CFM ESP IN. WG. POWER NOMINAL TONS ARI EFFICIENCY EER-SEER ENT AIR TOTAL SENS. SENS. kW COMPRESSOR MFS/MCB AMPS AMBIENT TEMP. MFG. MODEL REMARKS DB WB kBtu/h kBtu/h kBtu/h QTY. RLA (E)RTU-1 1,600 270 0.8 208/60/3 4 -- 77.8 65.0 48 38 - - 1 - 15 95'F CARRIER 50KC-AO5 1 (E)RTU-2 3000 AS IS 0.8 208/60/3 7.5 -- 77.8 65.0 90 78 - - 1 - 25 95'F LENNOX KCA09034 1 2 (E)RTU-3 2,000 AS IS 0.8 208/60/3 5 -- 77.8 65.0 60 49 - - 1 - 25 95'F LENNOX ZCA060 1 NOTES: EXISTING UNITS, NOT ALL DATA IS AVAILABLE. R SERVICE UNITS ACCORDING TO SERVICE NOTES AND BALANCE APPROPRIATELY. NEW PACKAGED ROOF TOP UNIT SCHEDULE (ALTERNATE MFG. INCLUDE LENNOX OR TRANE.) BLOWER COOLING COOLING CAP HEATING CAP (ELEC.HEAT) POWER MARK CFM 0/A CFM ESP IN. WG. POWER V/phase NOMINAL TONS ARI EFFICIENCY MOTOR HP ENT AIR TOTAL kBtu/h SENS. kBtu/h KW AT 208/30 HEAT CAP. kBtu/h CONDENSER FAN COMPRESSOR MCA AMPS MOCP AMPS AMBIENT DB/WB FILTER TYPE WT LBS MFG. MODEL REMARKS EER IEER SEER DB WB QTY. FLA QTY. RLA LRA RTU-4 2,000 200 0.8 208/30 5 16.0 1.4 79.0 66.5 71.9 49.7 7.9 27.0 1 1.5 1 16.2 110 39 45 95'F 2"/30% 604 CARRIER 50GC*MO6 1 2 03 4 5 6 7 $ 09 NOTES: 1 PROVIDE WITH 7-DAY PROGRAMMABLE THERMOSTAT (HONEYWELL OR EQUAL). DUCT MOUNTED SMOKE DETECTOR, FURNISHED BY FIRE ALARM CONTRACTOR AND INSTALLED BY MECHANICAL CONTRACTOR. O3 PROVIDE WITH A MANUFACTURER'S STANDARD INSULATED 14- ROOF CURB. MUST INCLUDE SHIM KIT TO INSTALL UNIT DEAD-LEVELH NO EXCEPTIONSII ® PROVIDE WITH A 25% OUTDOOR AIR HOOD WITH 2-POSITION MOTORIZED BALANCING DAMPER, MESH FILTER AND BIRDSCREEN. ELECTRICAL CONTRACTOR SHALL PROVIDE ALL SERVICE DISCONNECTS & FUSING. © ELECTRIC HEAT TO BE SINGLE POINT CONNECTION. © PROVIDE LOW AMBIENT ACCESSORY KIT. ® PROVIDE WITH HUMIDIMIZER OPTION. 09 PROVIDE WITH 2 STAGE COOLING. ® PROVIDE MANUFACTURERS OVERFLOW PAN DRAIN SWITCH. 01 PROVIDE WITH MANUFACTURER'S UPGRADE CONDENSER COIL COATING. © CONNECT TO KEF-2. RTU TO RUN WHEN KEF-2 IS RUNNING. NEW FAN SCHEDULE (ALTERNATE MFG. INCLUDE GREENHECK AND PENBARRY.) GENERAL CONSTRUCTION MARK CFM SONES ESP (IN-WG) ELEC. MOTOR DRIVE TYPE FAN MANUF. MODEL WEIGHT (Ibs) NOTES EF-1 70 2.0 0.375 120/1-0H 41 WATTS DIRECT CEILING COOK GC-148 15 01 02 03 NOTES: 01 PROVIDE FAN WITH BACKDRAFT DAMPER, GEMINI ISOLATOR KIT. 02 DISCONNECT BY ELECTRICIAN. INTERLOCK WITH LIGHTS IN RESPECTIVE ROOM BY ELECTRICIAN. 03 PROVIDE WITH ROOF MOUNTED EXHAUST CAP TO SERVE ALL FANS (SEE DETAIL). VENTILATION AIR SCHEDULE (E)RTU-1 SPACE FUNCTION AREA (SQFT) REQUIRED 0 OUTSIDE AIR REQUIRED 01 NUMBER PEOPLE (Pz) ZONE 01 AIR DISTRIB. EFFECTIVE. SYSTEM(]) VENT.(Ev) EFFICIENCY REQUIRED@ OUTSIDE (Vbz) AIR (CFM) REQUIRED 1 EXHAUST AIR (CFM) PROVIDED EXHAUST AJR (CFM) DINING 350 7.5 LfM + 0.18M PERSON SQFT 12.6 (70-PERSONS) 1,000-SQFT 1.0 0.7 127 -- -- HALLWAYS 420 0.06 SSQ -- 1.0 1.0 85 -- -- SYSTEM POPULATION, Ps: 24 TOTAL ZONE POPULATION, I Pz 24.5 REQU. OUTSIDE AIR INTAKE,(Vot) (=Vou / MAX Ev) (CFM) 268 OUTSIDE AIR INTAKE UNCORRECTED,(Vou) (=DxFRpPz+FRaAz) 268 PROVIDED OUTSIDE AIR INTAKE (CFM) 270 -7 OCCUPANT DIVERSITY, D (=Ps/ E Pz) 0.98 TOTAL PRESSURE = PROVIDED INT.- PROVIDED EXH. (CFM) 270 NOTES: 01 REQUIREMENTS IN ACCORDANCE WITH TABLE' 403.3.1.1, IN THE 2020 FLORIDA BUILDING CODE - MECHANICAL. VENTILATION AIR (E)RTU-2 AND (E)RTU-3 LEAVE AS IS, NO CHANGE IN THIS AREA. NEW AIR DEVICE SCHEDULELTERNATE MFG. INCLUDE METALAIRE AND PRICE.) GENERAL CONSTRUCTION MARK TYPE FUNCTION FRAME SIZE PATTERN MATERIAL FINISH MFG. MODEL NOTES CD CEILING DIFFUSER SUPPLY 24x24 LOUVERED FACE ALUMINUM WHITE PRICE AMD O CD2 CEILING DIFFUSER SUPPLY 12X12 LOUVERED FACE ALUMINUM WHITE PRICE AMD O RGC RETURN GRILLE RETURN SEE PLANS BLADES ALUMINUM WHITE PRICE 630DAL 01 NOTES: 01 PROVIDE WITH OPPOSED BLADE DAMPER. VENTILATION AIR SCHEDULE RTU-4 FUNCTION REQUIRED 0 REQUIRED 10 ZONE 01 SYSTEM 01 REQUIRED Q REQUIRED 1 PROVIDED SPACE AREA OUTSIDE AIR NUMBER AIR DISTRIB. VENT.(Ev) OUTSIDE (Vbz) EXHAUST EXHAUST (SOFT) PEOPLE (Pz) EFFECTIVE. EFFICIENCY AIR (CFM) AIR (CFM) AIR (CFM) OFFICES 100 5 f" + 0.06� 0.5 (5-PERSONS) 1.0 1.0 8•5 PERSON SOFT 1,000-SQFT KITCHEN 160 20 CFM + 0.12 M + 0.7 SAY XH. 0.8 ( 5-PERSONS) 1.0 1.0 112 -- 1300 PERSON SQFT SQ� 1,000-SQFT PREP 143 5 911 + 0.06 CFM 0.7 ( 5-PERSONS) 1.0 1.0 12.2 -- -- PERSON SQFT 1,000-SQFT HALLWAYS 240 0.06 SOFT -- 1.0 1.0 14.4 -- -- RESTROOMS 0 70 TT IEM 1-TOILET -- -- -- 70 70 SYSTEM POPULATION, Ps: 2 TOTAL ZONE POPULATION, E Pz 2 REQU. OUTSIDE AIR INTAKE,(Vot) (=Vou / MAX Ev) (CFM) 147 OUTSIDE AIR INTAKE UNCORRECTED,(Vou) (=DXERpPz+FRaAz) 147 PROVIDED OUTSIDE AIR INTAKE INCL. MUA-2 (CFM) 1300 OCCUPANT DIVERSITY, D (=Ps/ E Pz) 1.0 TOTAL PRESSURE = PROVIDED INT.- PROVIDED EXH. (CFM) -70 NOTES: 10 REQUIREMENTS IN ACCORDANCE WITH TABLE, 403.3.1.1, IN THE 2020 FLORIDA BUILDING CODE - MECHANICAL. NEW AREA AIR BALANCE SCHEDULE EF-I 70 CFM KEF-2 1500 GFM (E)RTU-1 270 GFM RTU-4 200 GFM MUA-2 1100 GFM FRESH + 1570 CFM EXHAUST - 1370 CFM TOTAL EXHAUST 1370 TOTAL FRESH 1570 CFM TOTAL BLDG. PRESSURE + 200 CFM NOTE THE EV=1.0 AND EZ=1.0 PER FBG-M, 405 01111111 0 000 V) 0 � co H N uo O L� Y in V) w W c -�. i � a: W M vi uj0; 0 0�a o N3a..K 3 w a a- 00 0 L fQ £_ E o L o > IS Q � E � o 0 z L O p 4- OC Q (� t!i Q J n 0� 011 O l� 00 C) OL J O--I co ry C) LI � � N W ti AH a F No 56189 it - ©'. STATE 0 0 r i /Of\ Date: 4. 25. 22 Checked by: ML Drawn: TJ/KB Job: 21-042 Sheet M002 ROOFTOP UNIT CASING --.a, GASKET/SEALING MATERIAL TREATED WOOD NAILER INSTALLATION SHALL BE IN ACCORDANCE WI STATE BUILDING CODE WIND LOADING REQUIREMENTS FOR THIS LOCATION RTU MFG'S SHEET METAL CURB SECUREMENT TO DECK (REFER TO STRUCTURAL ENGINEER'S PLANS & DETAILS) FIBER CANT ROOFING INSULATION ROOF DECK CURB SUPPORT STEEL FRAME MEMBER (REFER TO STRUCTURAL ENGINEER'S PLANS) ATTACHMENT OF ROOFTOP CURBS SCALE: NONE U O3 1-1/2" HANGER STRAPS; MAX. 10' SPACING O4 ROUND SNAPLOCK DUCT WITH WRAP INSULATION TAKE -OFF OR SPIN -IN FITTING W/ VOLUME DAMPER. 55 . (DON'T USE VOLUME DAMPER ABOVE GYP CEILINGS) OPROVIDE PLASTIC ELBOW STRAIGHTENER TO ELIMINATE KINKS AT ELBOWS FLEXIBLE DUCT - PROVIDE FLEXFLOW, OR EQUAL. O7 METAL COLLAR WITH BAND CLAMP, SCREWED (3) PLACES AND TAPED TYPICAL BOTH ENDS OF FLEX DUCT. O8 INSULATED FLEXIBLE DUCT, MAXIMUM 6' LENGTH. INSTALL FLEX -DUCT AS STRAIGHT AS POSSIBLE. NO BEND OVER 90% NO CRUSHING OF FLEX -DUCT. O2" WRAP INSULATION OVER BACK OF DIFFUSER SUPPLY DUCT AND DIFFUSER RUN -OUT DETAIL SCALE: NONE MAXIMUM SAG 1 /2" PER FOOT OF SUPPORT SPACING 1-1 /2" x 22 GA. SADDLE 1-1/2"x22 GA. WIDE BAND CLAMP Zi-1/2"x22 GA. WIDE BAND CLAMP OR OUTDOOR AIR INTAKE. O O2 UNIT IDENTIFICATION PLATE SCREWED TO UNIT. O3 DISCONNECT SWITCH. DO NOT MOUNT HIGHER THAN UNIT. O4 INSULATED PREFAB CURB WITH FIBER CANT. OPATE PIPING PLUG FOR CONTROL, DO NOT RUN IN POWER CONDUIT. DO NOT USE "PATE" PIPING PLUGS AS NOTED WHERE UNIT MANUFACTURER HAS PROVIDED OPENINGS INSIDE PERIMETER CURB. OCUT HOLE IN ROOF ONLY LARGE ENOUGH FOR DUCT & PROVIDE STRUCTURAL SUPPORT FOR DECKING. O7 CONDENSATE TRAP (REFER TO DETAIL). ROUTE CONDENSATE AS INDICATED ON DRAWINGS. OFLEXIBLE CONNECTION. OSMOKE DETECTOR IF REQUIRED ACCORDING TO PLAN. 10 12"X12" INSULATED ACCESS PANEL. 11 1200 CFM (OPEN RETURN WITH 1"X1" GALVANIZED WIRE SCREEN COVER ON DROP DOWN) ROOFTOP UNIT DETAIL SCALE: NONE 12-GAUGE HANGER WIRE (TYPICAL) 17 Z-10, E� TOIhL MMIltiM EXTENSION = 3" MAXIMUM HANGER SPACING 8-FT UNISTRUT OR 3"X2" CHANNEL 3„ (TYPICAL) HANGER AND SUPPORT FOR RECTANGULAR DUCTS NO SCALE 1-1 /2" x 22 GA. SADDLE HANGER AND SUPPORT FOR ROUND AND FLEXIBLE DUCTS NO SCALE FAN BASE OVERHANG TIE -DOWN BY GC PER STRUCTURAL PLANS INSULATION FAN MFG'S ROOF CURB FLASHING FIBER CANT FINISHED ROOF TIE -DOWN BY GC PER STRUCTURAL PLANS ROOF DECK — ANGLE IRON SUPPORT WALL CAP WITH BIRD SCREEN (PAINT TO MATCH WALL) EXTERIOR WALL 1 /4X20 TPI ALL THREAD" SUPPLIED BY MC. —� CEILING EXHAUST FAN BACKDRAFT DAMPER EXHAUST DUCT SEE PLANS FOR SIZE AND ROUTE GEMINI ISOLATOR KIT. CE JQ FAN DETAL SCALE: NONE GALV. STRAP PIPING SCREW END OF STRAP TO PIPE SUPPORT 12" WIDE UNISTRUT TOP ON TOP OF SUPPORT PROVIDE ROOFING MATERIAL UNDER SUPPORT (GLUE TO ROOF & SUPPORT) ROOF MIRO INDUSTRIES, MODEL# 2.5, PIPE SUPPORT RIGID POLYCARBONATE RESIN (PROVIDE EVERY 4'-0") ROOF PIPE SUPPORT DETAIL SCALES NONE GASKETING WOOD NAILER FAN ROOF CURB MOUNTING DETAIL NOT TO SCALE FINISHED GRADE -\ MIN. y SCH. 40 PVC CONDENSATE DRAIN PIPING 24"0 PVC PIPE W/ END CAP of DRYWELL DETAIL NO SCALE COARSE ROCK �1111111 amm� Q- �9 L � � 8 O o> CL o > Q s s 4) L O N r` Z Ln ° 0z o Q 0z J O O mLi— O Q OL < <C Z 4-J >_ Q = r v m w � v IJ W D���''� ENS--•.�G��� No .56189 M*. �'. STATE OF rriri Date: 4. 25. 22 Checked by: M1. Drawn: TJ/KB Job: 21-042 Sheet M003 Nnnn TN'FnRiVATTnAT — .inR S.gSi'4R9 MAX EXHAUST PLENUM TOTAL HOOD C❑NFIG RISER(S) END T❑ HOOD TAG MODEL MANUFACTURER LENGTH COOKING TYPE APPLIANCE DESIGN TOTAL SUPPLY HOOD WIDTH LENG HEIGHT DIA CFM VEL SP NO TEMP DUTY CFM/FT EXH CFM CFM CONSTRUCTION END ROW 5424 600 430 SS 1 CAPTIVEAIRE 5' 6' DEG I HEAVY 236 1300 4' 12' 1300 1655 -0,922' 1100 ALONE ALONE ND-2-PSP-F WHERE EXPOSED, unnn TNFn141UATTnAT FILTER(S) LIGHT(S) UTILITY CABINET(S) HOOD TAG EFFICIENCY @ 7 WIRE FIRE SYSTEM ELECTRICAL SWITCHES FIRE SYSTEM HOOD HANGING TYPE SIZE MODEL # QUANTITY NO TYPE QTY HEIGHT LENGTH MICR❑NS QTY TYPE GUARD LOCATION SIZE PIPING WEIGHT 1 CAPTRATE SOLD FILTER 4 16' 16' 85% SEE FILTER SPEC 3 SCREW IN HALOGEN NO LEFT 12'x54'x24' TANK FS 4.0 SC-311110MA 1 LIGHT YES 705 1 FAN LBS Nnnn n➢TTn1V.lz? HOOD TAG ❑PTION NO FIELD WRAPPER 20,00' HIGH FRONT, LEFT, RIGHT, RISER SENSOR INSTALL 6IN PLEN, RIGHT VERTICAL END PANEL 27' TOP WIDTH, 21' BOTTOM WIDTH, 80' HIGH INSULATED 430 1 SS, LEFT VERTICAL END PANEL 27' TOP WIDTH, 21' BOTTOM WIDTH, 80' HIGH INSULATED 430 SS. PF. RFnRQ TFn .S'TTP➢T.Y PT.F. ATTTAf(.';� ) RISER(S) HOOD N❑ TAG P❑S LENGTH WIDTH HEIGHT TYPE WIDTH LENG DIA CFM SP MUA 10, 28' 550 0.141' 1 Front 78' 16' 6' MUA 1 10' 1 28' 550 0,141' EXHAUST RI HANGING At 16' CAPTRATE FILTER WITH i 3' INTERNAL STAN] IT IS THE RESP❑NSIB] OF THE ARCHITECT/OWNE ENSURE THAT THE HOOD CLEAR FROM LIMITED -COMBUST AND COMBUSTIBLE MATEF IS IN COMPLIANCE LOCAL CODE REQUIREMI 42 TO 48 INCHES ABOVE FLOOR LEVEL TO CENTER OF PUSH STATION 1 GREASE I WITH REMOVABLE SECTION VIEW - MODEL 5424ND-2-PSP-F HOOD - # 1 SCREW IN HALOGEN BULB, L55 SERIES E26 CANOPY LIGHT FIXTURE - HIGH TEMP ASSEMBLY, R THERMAL AND SHOCK RESISTANT DEEP HANDY/JB❑X REQUIRED FOR FIRE SUPPRESSION MANUAL ACTIVATI❑N DEVICE MANUAL ACTIVATI❑N DEVICE SHOULD BE LOCATED 10-20' AWAY FROM HOOD IN PATH OF EGRESS. REFER TO LIFE SAFETY PLAN FOR FINAL LOCATION /RAPPER 20.00' HIGH IOD ❑PTIONS TABLE). rTACHING PLATES. 23.5% OPEN STAINLESS STEEL PERFORATED PANEL, ROOM TEMPERATURE SENSOR Provides room override based on temperature differential between the room and duct. Installed by electrician on a wall, 5'-6' off the finished floor, in the space but not directly under the hood or close to an appliance (including the electrical control box) so the reading Is accurate for space, HOOD CONTROL INTERFACE a o The LCD Interface provides user control and hood status. The faceplate Is connected to the hood control panel through CAT-5 cable. A faceplate has 2 RJ-45 connectors. One connects to port J4 or J5 In the hood control panel and the other will typically be occupied by a RJ-45 end -of -line terminator, REVISIONS HOOD CORNER SUPPLY PLENUM DESCRIPTION 1/2' - 13 TPI HANGING ANGLE 1/2' - 13 TPI HANGING ANGLE GRADE 5 (MINIMUM) (HARDWARE BY INSTALLER) GRADE 5 (MINIMUM) (HARDWARE BY INSTALLER) STEEL HEX NUTS, STEEL HEX NUTS. 1 1/2' GRADE 5 /2' GRADE 5 (MINIMUM) STEEL (MINIMUM) STEEL FLAT WASHER. FLAT WASHER, 0 1/2' - 13 TPI 1/2' - 13 TPI GRADE 5 (MINIMUM) GRADE 5 (MINIMUM) STEEL ALL -THREAD. STEEL ALL -THREAD. 1/2' - 13 TPI GRADE 5 (MINIMUM) 1/2' - 13 TPI STEEL HEX NUT, GRADE 5 (MINIMUM) STEEL HEX NUT, SUPPLY PLENUM 1/2'HANGING GRADE 5 HOOD CORNER ANGLE E (MINIMUM) (MINIMUM) STEEL HANGING ANGLE 1/2' GRADE 5 W EIGHT BEARING FLAT WASHER. (WEIGHT BEARING 8 ANCHOR POINT FLATWASHER.FOR SUPPLYT FOR HOOD). PLENUM). L r_ 8 LM 1/2' GRADE 5 (MINIMUM) STEEL (MINIMUM)GRADE STEEL FLAT WASHER. W FLAT WASHER, 1/2' - 13 TPI 1/2' - 13 TPI GRADE 5 (MINIMUM) STEEL HEX NUT. STEEL HEX NUTS. ASSEMBLY INSTRUCTIONS ASSEMBLY INSTRUCTIONS HANGING ANGLE MUST BE SUPPORTED WITH 1/2' - 13 TPI HANGING ANGLE MUST BE SUPPORTED WITH 1/2' - 13 TPI GRADE 5 (MINIMUM) ALL -THREAD. SANDWICH HANGING GRADE 5 (MINIMUM) ALL -THREAD, SANDWICH HANGING ANGLES AND CEILING ANCHOR P❑INTS WITH 1/2' GRADE 5 ANGLES AND CEILING ANCHOR POINTS WITH 1/2' GRADE 5 (MINIMUM) STEEL FLAT WASHERS AND 1/2' - 13 TPI (MINIMUM) STEEL FLAT WASHERS AND 1/2' - 13 TPI GRADE 5 (MINIMUM) HEX NUTS AS SHOWN, MUST USE GRADE 5 (MINIMUM) HEX NUTS AS SHOWN, MUST USE DOUBLED HEX NUT CONFIGURATI❑N BENEATH HOOD HANGING DOUBLED HEX NUT C❑NFIGURATI❑N ABOVE CEILING ANGLES AND ABOVE CEILING ANCHORS, MAINTAIN 1/4' OF ANCHORS, SINGLE HEX NUT BENEATH HANGING ANGLE IS EXPOSED THREADS BENEATH BOTTOM HEX NUT, TORQUE ACCEPTABLE FOR PSP HANGING ANGLES, MAINTAIN 1/4' OF ALL HEX NUTS TO 57 FT-LBS, EXPOSED THREADS BENEATH BOTTOM HEX NUT, TORQUE ALL HEX NUTS TO 57 FT-LBS, 0 ( C� i C rILITY 4BINET, VERIFY CEILING HEIGHT HEIGHT REQUIRED TO VERIFY THAT HOOD FITS SPACE AND TO SIZE THE ENCLOSURE PANELS 8 pC U a� co rn _i Q W (V rn rn 00 M M M M oo W Z 0 a �o (M M J 1L a H CD LO (n 0 0c a) 0 0 rn LO It i L� I � FIELD INSTALLED T-STAT r IRE HERMISTOR � S U.L. LISTED SCREW IN HALOGEN BULB, S � (L Ln N M I M 0O > d > � S d M n M 0) r-� I-- N PLAN VIEW - HOOD #1 5' 6.00' LONG 5424ND-2-PSP-F FOR REFERENCE ONLY !!I ALL WORK TO CONFORM TO FL. BLDG. CODE - 7TH EDITION 2020 MECHANICAL and 7th Edition Fire Code (NFPA96) latest adopted version DATE: 4/25/2022 DWG.#: 5366481 DRAWN Y: celso.saenz SCALE: 3/4" = 1'-0" MASTER DRAWING SHEET NO. 1 01111111 rn V) N c 900 (0 La ? F—Cq LO W N W Q y� w Y NSA (/1 ^ w W oW-M a Z 0.OW 00 CL p UMqh N W Z cc w //� n"I 1 y J V I C4W Q ri N3dQ W Q U_ co (19 1O L C1 Ji 0) E .L Q gg $S U di o > �o �x L N >_ 2 p �n a pEj to N €�g s s o t` lTi Q W Z r-1 <> O Z " W_ o 1--- � `j �C � J (� c) 0 Q N I L� Q d Q ks) J C) J 0 cUQnOC z 1, LL J n }- C)colW � � N w t��ti�nurrrrr 1� �Q,•.•��G E•N SF:•. �Lr,�., No 56189 Q'. :STATE OF �.' A, irON A�- '+++unrrs� ' Date: 4. 25. 22 Cbeeked by: ML Drawn: TJ/KB Job: 21-042 Sheet M004 F'XFTATI"ST FAN TNFnR/LfATTnAi — .inR_S.`3i3l74Rl FAN UNIT TAG QTY FAN UNIT MODEL # MANUFACTURER CFM ESP RPM MOTOR HP BHP PHASE VOLT FLA DISCHARGE WEIGHT S❑NES NO ENCL VELOCITY (LBS) 1 KEF-2 1 DU85HFA CAPTIVEAIRE 1300 1,500 1422 ❑DP 0,750 0.5190 3 208 2,6 411 FPM 99 13.6 30 TOP VIEW I I 1 I 1 I 1 I 1 I 1 22 1/2 1 I I 1 24 y�/4 —� 31 7/8 24 3/4 CAPTIVE-AIRE HOODS ARE BUILT IN COMPLIANCE WITH BUILT a IN ACCORDANCE WITH NFPA No. 96 %D�ISTCD Intertek NEPA #90 UL 710 8( ULC710 STANDARDS E.TIL, LISTED 3054804-001 FEATURES: - DIRECT DRIVE CONSTRUCTI❑N (N❑ BELTS/PULLEYS). - ROOF MOUNTED FANS. - RESTAURANT MODEL, - UL705 AND UL762 AND ULC-S645 - VARIABLE SPEED CONTROL. - INTERNAL WIRING. - THERMAL OVERLOAD PR❑TECTION (SINGLE PHASE), - HIGH HEAT ❑PERATI❑N 300°F (149'C). - GREASE CLASSIFICATION TESTING, - NEMA 3R SAFETY DISCONNECT SWITCH, NORMAL TEMPERATURE TEST EXHAUST FAN MUST OPERATE CONTINU❑USLY WHILE EXHAUSTING AIR AT 300"F (149'0 UNTIL ALL FAN PARTS HAVE REACHED THERMAL EQUILIBRIUM, AND WITHOUT ANY DETERIORATING EFFECTS TO THE FAN WHICH WOULD CAUSE UNSAFE ❑PERATI❑N. ABNORMAL FLARE-UP TEST EXHAUST FAN MUST OPERATE C❑NTINU❑USLY WHILE EXHAUSTING BURNING GREASE VAPORS AT 600'F (316"0 FOR A PERIOD OF 15 MINUTES WITH❑UT THE FAN BECOMING DAMAGED TO ANY EXTENT THAT COULD CAUSE AN UNSAFE CONDITION. OPTIONS GREASE BOX, MIAMI DADE CERTIFICATION - N❑A-1 ALUMINUM UPBLAST, DUCTWORK BETWEEN FAN BASE CERAMIC SEAL - INSTALLED AT EXHAUST RISER ON HOOD PLANT - FOR GREASE DUCTS, AND FAN (BY OTHERS), 2 YEAR PARTS WARRANTY. F VENTED CURB. 6 GAUGE ,TEEL :ONSTRUCTION, _ ROOF ❑PENING 22 1/2 DIMENSIONS, 22 1/2 PITCHED CURBS ARE AVAILABLE 00 FOR PITCHED ROOFS. 0° SPECIFY PITCH: 12' EXAMPLE: 7/12 PITCH = 30° SLOPE, f. TTR R A .S'.SF. ILfRT.TF..S No FAN TAG WEIGHT ITEM SIZE 1 # 1 70 LBS CURB 23,000'W X 23.000'L X 26,000'H ALONG LENGTH, RIGHT VENTED HINGED 16 GAUGE, 2 # 2 MUA-2 29 LBS CURB 21.000'W X 21.000'L X 20,000'H ALONG WIDTH, RIGHT INSULATED, MIAMI-DADE NOA1 ALUMINUM UP -BLAST FANS GENERAL NOTES: L THIS APPROVAL IS FOR THE STRUCIIRAL CAPACITY AND DPACT RATING OF THE EXTERDR HWSDIG ONLY) IT DOS NOT DUN ANY ITERDR NEDMISH OR ELECTRICAL PART. 2 THESE FANS HAVE MR BEETH WIND TESTED FOR WIND DRIVEN RAIN TEST PER FLORIDA REM CODE, TASM W-%. i TESTED IN ACCORDANCE TO FLMM RUN CODE TEST PROTOCOL TASM TAS202, TAM 4 TESTED FOR AREAS INCLUDING HIGH VELOCITY HIDNRICAIE ZONES. I TESTED UNDER KAKI DADE MINTY NOTIFICATION WOOER ATI OBD33 INSTALLATION INSTRUICTION& L SECURE LID TO FAN USK (8) 1/4'-14 X I' ZINC PLATED STEEL SELF DRILLING SHEET METAL SCREWS WITH EDGE DISTANCE RUBBER WASHER SPACED EVENLY AROUND LID. 2. SECURE FAN BASE TO CURB USING 1/4'-14 X 2' GALVANIZED SELF DRILLING ELDED CURB CORNERS PREEPUNCHEDD HOLESINF E. IVE 20' HEIGHT). (SEE TABLE BELOW FOR QTY). I SECURE CURB TO ROOF ON WALL BY DRDI.INL 1/4' DIA PILOT HOLES IN THE CURB FLANGE AT UOCATOINS SHOWN IN THE DIAGRAK SEE TABLE BELOW FOR FASTENER TYPE, USE TABLE BELOW FOR FASTENER QTY. CURB MATERIAL,DESIGN 2r HIGH 6 LESS = 20 GA. STEEL PRESSURE: +150A / -150,0 PSF. ABOVE 20' THRU 42' = 16 GA STEEL. LARGE HOSSO.E IN PACT RESISTANT. INSTALLATION FASTENER TYPES WOOD (8G 0.42 CONCRETE (2500 PSI FAN TO CURB MIN) STEEL (12 GAUGE MIN.) MIN. CRACKED CONCRETE) 5/16'-18 X 2' SELF 3/8' DIA ZINC 1l4"-14 DRIL-FLEX SELF 3/8" DIA. SS HILTI FASTENER DRILLING SCREW (ELCO PLATED LAG BOLT DRILLING SCREW KWIK BOLT TZ DRIL-FLEX OR BETTER) EXPANSION ANCHOR MINIMUM THREAD N/A 2-112' 12 GAUGE 2" PENETRATION MINIMUM EDGE N/A 1-1/2" 3/8' 3' DISTANCE MINIMUM END N/A 2-5/8" 3/8" 3" DISTANCE MINIMUM SPACING N/A 1-1/2" 3/4' 5-112" INSTALLATION FASTENER QTY CURB TO AN (ROOF) CURB TO AN (WALL) WOOD (ROOF) WOOD (WALL] STEEL (ROOF) STEEL (WAIL) CONCRETE (ROOF) CONCRETE (WALL) FAN MODEL PER SIDE TOTAL PER SIDE TOTAL PER SIDE TOTAL PER SIDE TOTAL PER SIDE TOTAL PER SIDE TOTAL PER SIDE TOTAL PER SIDE TOTAL DU180 3 12 3 12 5 20 5 20 6 24 6 24 5 20 1 5 1 20 SCREW DOWN THROUGH FAN BASE INTO CURB TOP FLANGE END DISTANCE. f7 DA n MIAMI-DADE NOA2 SUPPLY FANS GENERAL NOTES, L THIS APPROVAL IS FOR THE STRUCTURAL CAPACITY AND IMPACT RATING OF THE EXTERIOR HOUSING ONLYj IT DIES NOT INCLUDE ANY INTERIOR NECIWDSH OR ELECTRICAL. PART, Z THESE FANS HAVE NOT BEEN WIND TESTED FOR WIND DRIVEN RAIN TEST PER FLORIM BUILDING CODE, TAS100 W-95, 3, TESTED IN ACCORDANCE TO FLORIDA BUILDING CODE TEST PROTOCOL TA201, TAS202, TAS20I 4. TESTED FOR AREAS INCLUDING HIGH VELOCITY HURRICANE ZONES. I TESTED UNDER NIAMI-DADE COUNTY NOTIFICATION NUMBER ATI-08034, INSTALLATION INSTRUCTIONS, I. SECURE FAN BASE TO TOP OF CURB USING 1/4-14 X Y ZINC PLATED STEEL SELF DRILLING SCREWS (A307 OR BETTER) THROUGH FAN BASE. SEE TABLE BELOW FOR QTY. 2. SECURE CURB TO ROOF FRAMING MEMBERS BY FANDRILLING 1/4' DIA PILOT HOLES IN CURB AT LOCATION SHOWN IN BOTTOM LEFT DIAGRAM. SEE TABLE BELOW FOR FASTENER TYPE AND QTY. DESIGN PRESSURE, +30A / -130A PSF. LARGE MISSILE (PACT RESISTANT, INSTALLATION FASTENER TYPES WOOD (8G 0.42 CONCRETE (2500 PSI FAN TO CURB MIN.) STEEL (12 GAUGE MIN.) MIN. CRACKED CONCRETE) 1/4"-14 X 1" SELF 3/8" DIA. ZINC 1/4"-14 DRIL-FLEX SELF 3/8" DIA. SS HILTI FASTENER DRILLING SCREW (A307 PLATED LAG BOLT DRILLING SCREW KWIK BOLT TZ OR BETTER) EXPANSION ANCHOR MINIMUM THREAD WA 2" 12 GAUGE 2-5/16" PENETRATION MINIMUM EDGE N/A 1-1/2' 3/8" 3" DISTANCE MINIMUM END N/A 2-5/8" 3/8" 4' DISTANCE MINIMUM SPACING N/A 1-1/2' 3/4" 7" INSTALLATION FASTENER QTY CURB TO FAN WOOD STEEL CONCRETE FAN MODEL TANG SHORT TOTAL LONG SNORT TOTAL LONG FlR STD! TOTAL LONG SNORT TOTAL BIDE SIDE SIDE SIDE SIDE FIDE SIDE MODULAR 3 2 10 5 4 18 4 3 14 4 3 14 2 MIAMI-DADE COUNTY - CURB ROOF INSTALLATION GUIDE CURB. 22 GMSTT� NNK - 0.42 N MI/ CURB. - --Y FW"ORR SEIZIELES 331r TV, vllou u �,42 NDL STEED 12 GAIA BIN, SUBSTRATE, FOR REFERENCE ONLY !!! nn L n REVISIONS u d LD Ln m m L1 DATE: 4/25/2022 DWG.#: 5366481 Cp U a� co rn 22) w 04 LJ7 rn xCF) Q w 00 M LO v M 00 l.Ll Z O a chi M fM J lL o. F- LO a) U) v 0 EC O rn O 0) 0 O) LOT_ DRABY celso,saenz SCALE: 3/4" = 1'-0" MASTER DRAWING SHEET NO. 2 a ��/ L ,�//•V/ �� M 0) GLLJ CO ai V 0 H t W �+ U .J Q rn t I 0 3M J w Y u) c'I LLJ N w Zd 0CWL a Q ` WW. c SS Q W V M S CL Z —' H EN•4 w < m Q- CID Q9 d' C� {{ L IL N E O g � > o m L L c 6*Q RN; N > Q (Q N E a q N= H EL L o a O N X Lo w L_ OQ(r) (O Q (f i J t6 O m Q Q 1<1' V Q.)1. Z -1--) ' n W F+ q 1� AH a L1LULLrurrr W D �� • �C•E.Ng .•Gj,,'i No 56189 =p STATE OF 'r,0-. Al OHlO lS/ANAL �rrTLLnIUL Date: 4. 25. 22 Checked by: ML Drawn: TJ/KB Job: 21-042 Sheet M005 MUA FAN INFORMATION - JOB,#536648 9 FAN UNIT TAG QTY FAN UNIT MODEL # BLOWER H❑USING MIN DESIGN ESP RPM MOTOR HP BHP PHASE VOLT FLA MCA MOCP WEIGHT SONES NO CFM CFM ENCL (LBS) 2 MUA-2 1 EA-Al-15D 15MF-1-MOD Al - 1100 0,500 1299 ❑DP 0,750 0,3280 3 208 2.5 3,2A 15A 265 13.4 FAN #2 EA-Al-15D - SUPPLY FAN (KSF-1) 1, UNTEMPERED SUPPLY UNIT WITH 15' MIXED FLOW DIRECT DRIVE FAN IN SIZE #1 HOUSING, 2. INTAKE HOOD WITH EZ FILTERS. 3. DOWN DISCHARGE - AIR FLOW RIGHT -> LEFT. 4. DOWN DISCHARGE CONSTRUCTION FOR SIZE 1 UNTEMPERED DIRECT DRIVE AHUS, 5. GRAVITY BACK DRAFT DAMPER, 16' WIDE X 18' HIGH, STANDARD GALVANIZED CONSTRUCTION, 1 1/4' REAR FLANGE, FOR SIZE 1 UNTEMPERED FAN HOUSING (5181). 6. MIAMI DADE IMPACT AND WIND LOAD CERTIFICATION +30 / -130 PSF - MIAMI DADE COUNTY PRODUCT CONTROL APPROVED, FLORIDA BUILDING CODE APPROVAL, ROOF MOUNT EXHAUST CURBS UP TO 20' HIGH MUST BE 16 GAUGE ALUMINIZED. 7. HINGED DOUBLE WALL INSULATED DOOR ASSEMBLY (BURNER/BLOWER SECTI❑N). 8.2 YEAR PARTS WARRANTY wN❑TEt SUPPLY DUCT MUST BE INSTALLED TO MEET SMACNA STANDARDS, A MINIMUM STRAIGHT DUCT LENGTH MUST BE MAINTAINED DOWNSTREAM OF UNIT DISCHARGE AS ❑UTLINED IN AMCA PUBLICATI❑N 201. WHEN USING RECTANGULAR DUCTWORK, ELBOWS MUST BE RADIUS THROAT, RADIUS BACK WITH TURNING VANES. FLEXIBLE DUCTWORK AND SQUARE THROAT/SQUARE BACK ELBOWS SHOULD NOT BE USED. ANY TRANSITION AND/OR TURNS IN THE DUCTWORK WILL CAUSE SYSTEM EFFECT, SYSTEM EFFECT WILL DRASTICALLY INCREASE STATIC PRESSURE AND REDUCE AIRFLOW, D❑ NOT RELY ON UNIT TO SUPPORT DUCT IN ANY WAY, FAILURE TO PROPERLY SIZE DUCTWORK MAY CAUSE SYSTEM EFFECTS AND REDUCE PERFORMANCE OF THE EQUIPMENT• SUGGESTED STRAIGHT DUCT SIZE IS 14' x 14', LIFTING LUG, 3 20' EQUIPMENT CURB. 2 1' ROOF OPENING 2' SMALLER THAN CURB DIMENSION• 7 L 13 6 3/8' DI M% /rn T1 T C1 rli IAf9rr FOR FIELD WIRING. 32 1/8' AIRFLOW, SERVICE DISCONNECT 29 3/4' SWITC BLOWER/MOTOR ACCESS DOOR 24' SERVICE CLEARANCE REQ. MINIMUM STRAIGHT DUCT PER AMCAA �~ 29'- I 1 I 1 MIN, 14' 76 1/2' AIRFL❑W, FOR REFERENCE ONLY !ll ELECTRICIAN NOTES All Hood/Fan/EMS/UDS/PCU electrical connections and interconnections to be provided and installed by Electrician, Electrician to provide, install, and land wiring between hood Lights, hood temp sensors, remote Ansul system microswitches, and any other component requiring an electrical connection to the Captive -Aire electrical package, Failure by the Electrician to make ALL required electrical connections and interconnections will result in the electrical controls not working properly. Any loss or failed test as a result of electrical controls not working properly is the responsibility of the Electrician, Light bulbs for kitchen hoods to be provided and installed by electrician, GENERAL NOTES : 1. ELECTRICAL HOOK-UP TO CAS MOTOR CONTROLS (MOTOR STARTERS, FAN SWITCHES, FAN DISC❑NNECTS, RELAYS, ETC. ) BY OTHERS, 2. FIRE CHASE BY OTHERS, IF REQUIRED, 3. ALL PHASES OF INSTALLATION SHALL COMPLY WITH NFPA 96. 4. WRITTEN MEASUREMENTS HAVE PRECEDENCE OVER SCALE. 5. PROVIDE CLEAN❑UTS IN EXHAUST AIR DUCTS AS INDICATED TO ALLOW CLEANING AT ALL BENDS AND HORIZ❑NTAL RUNS, 6. UNLISTED EXHAUST DUCT TO BE 16 GA. GAV STEEL ALL SEAMS AND J❑INTS TO HAVE A LIQUID TIGHT CONTINU❑US EXTERNAL WELD, 7. FAN TO HAVE A MINIMUM OF 10 FT, OF CLEARANCE FROM THE OUTLET TO ADJACENT BUILDINGS, PROPERTY LINES, AIR INTAKES OR 3 FT, VERTICAL CLEARANCE PER NFPA96 8. H❑RIZONTAL EXHAUST DUCT TO SLOPE NOT LESS THAN 1/4' PER FOOT TOWARD HOOD FOR DUCT LESS THAN 75' LONG. 1' PER FOOT SLOPE FOR DUCT LONGER THAN 75' 9. HOOD TO OVERHANG COKING EQUIPMENT 6' ON ALL OPEN SIDES, 10,EXHAUST DUCT TO BE PROTECTED FROM COMBUSTIBLES PER NFPA96 AND LOCAL CODE, 11,BUILDING PRESSURE SHALL NOT EXCEED 0.02' WATER COLUMN AT EXTERI❑R DOORS. 12.KITCHEN SHALL BE BALANCED TO BE NEGATIVE WITH RESPECT TO THE DINING ROOM, N 0 I 0 REVISIONS E 8 .� c to ill W 0 00 cM 6 M 00 Uj z' O s a' ACD M M U_ cd a E ca 0 Uj CO OI x 2LO Ui S S` Q W Ln f`J I M � O > C S V) L (:5 >1 4- S <Z5 M C CU M Q� N ) DATE: 4/25/2022 DWG.#: 5366481 DRAWN Y: celso,saenz SCALE: 3/4" = 1 '-0" MASTER DRAWING SHEET NO. 3 11111111 MCO 0) W V) 4 LLJ (14 Co N 4k Lj U ' 0 3 M -J lL Y n W Lt1 o Z pUM�, � Z / � J V Q a=W 3 W Q a - Go v � L _o Jj C1 Q a $ $ ld c > � c � gos 1� x Z W L Q cl `o~Qco 0 o�wQ 4-) In J � o�m0 O Q V�1WJ\ ts)f Q Q V 0 � 0 Q) C� ❑L 0 l�l LU E-:� N W ti A E•� i1+ No 56189 ►1 • STATE OF o P tS��NA'. Date: 4. 25. 22 Checked by: MI. Drawn: '1'J/KB Job: 21-042 Sheet M006 KEY NOTES ON PLANS: O1 NEW PACKAGED ROOFTOP A/C UNIT - COORDINATE FINAL LOCATION WITH G.C. �2 NEW ROOF MOUNTED EXHAUST FAN (SEE ECON AIR SHEETS). O3 EXISTING ROOFTOP UNIT. INSPECT AND SERVICE UNIT COMPLETELY. �4 COORDINATE THERMOSTAT/HUMIDITY SENSOR LOCATION WITH FURNITURE LAYOUT AND OWNER'S REP PRIOR TO ROUGH -IN OF BACKBOX AND WIRE. O ROUTE CONDENSATE PIPING ON PIPE SUPORTS AT 4-FT INTERVALS AND SPILL IN NEW DRYWELL. O6 INSTALL DUCT SMOKE DETECTOR IN SUPPLY DUCT DROP. O7 DUCTWORK OF THIS UNIT STAYS AS IS. ® EXISTING DUCTSMOKE DETECTOR, INSTALL NEW ONE IF NOT THERE OR NOT WORKING PROPERLY. O9 NEW DRYWELL FOR CONDENSATE DRAINS. 10 EXISTING EXHAUST FAN. 11 EXISTING FRESH AIR MAKE UP FAN. 12 NEW FRESH AIR MAKE UP FAN. (SEE ECON AIR SHEETS) 13 VOLUME DAMPER IN EACH BRANCH SUPPLY & RETURN DUCT (TYPICAL THROUGHOUT). LOCATE ABOVE LAY -IN CEILING ONLY. DAMPER TO BE ACCESSIBLE AFTER CONSTRUCTION IS COMPLETED. 14 CONNECT NEW FAN TO EXISTING WALL CAP. O3 E)RTU-3 iia , itxRIUIJLES i ODEMO FLOOR PLAN (,ALE; 1/4' = 1 NO WORK LEAVE RTU-'S. DEMO ALL DUCT FROM RTU-1 BACK TO TRUNK LINE. DEMO RESTROOM EXHAUST FAN AND DUCT. E)RTU-2 0 LEAVE ALL DUCTWORK,RTU'S AND FANS. ONLY DIFFUSERS TO BE CHANGED OUT. 9 (E)RTU-1 L: U) 'a O U) w 0 7 M coCT) O Ln CID O Ld Q V U � p 3 M 00 W Laa Cn 00 Z _ r p� V LA d a cqw ui u N 3 a w lil f— Q 6 d' N N � d if rnE - O L � Z C Q n r, E a- E l3 x _i I� O l�l < (�00 Z o (V d <1 J) I N Q 0- Q � N w 0 No 56189 srarE o /"I, Dale: 4. 25. 22 Checked bti : Ni 1, Drawn: T.I/hli J oh: 2+1-0<I,2 sheet. m 10 0 I,(j ' l I I (NEW) RTU-4 V IN (NEW) LOCATE FANS A MIN. OF 10-FT 0 SD © MUA-2 FROM FRESH AIR INTAKES (TYP) 1"CD 09 DRY -- -- -- _-_ - - --- --- - --- - - --------__ - --- ------ �------- -- ----- -- ----- - --- _-_ - T- WELL I I (NEW) KEF-2 03 E)RTU-3 E)RTU-2 O (`J I MEGHANICAL I,00F PLAN I/4' _ 1 320 CFM CD-8" 0 ATTIC ACCE55 107 ) 0 OFFICE jr)1 130 CFM CD-8" 0 10X10 13 400 CFM CD-10"0 320 CFM CD-8"0 09 DRY 50 CFM WELL TOILET CD2-6n0 (E)WALL 14 CAPR� 12" 0 6"0 EF-1 KEF-1 NOTE: FIELD COORD PRIOR TO FABRICATE OR INSTALL GREASE DUCT. CHEN (E)KEF-2 DISH WASHING n MECHANICAL CEILING PLAN 11 O (E)MUA- 130 CFM RGC-14x 14 22X18 20X10 20X10 © SD 400 CFM CD-10" 0 10X14 rT14X TOILET 835 CFM RGC-22X22 (TYP-2) 380 CFM CD-10"0 MUA-2 KITCHEN �D ® E)RTU-3 HALL _......____, _.. _ _ .. _ ._. .._ .... _ .. _....... .�.. 175 C CD-8' 5ER\ ....� /CASHIER I 0 EXISTING ROOF EXHAUST FAN I I Lx 1'� 0 (E)RTU-1 665 CFM RGC-18x 18 -2) KEY NOTES ON PLANS: 1O NEW PACKAGED ROOFTOP A/C UNIT — COORDINATE FINAL LOCATION WITH G.C. 02 NEW ROOF MOUNTED EXHAUST FAN (SEE ECON AIR SHEETS). 03 EXISTING ROOFTOP UNIT. INSPECT AND SERVICE UNIT COMPLETELY. 04 COORDINATE THERMOSTAT/HUMIDITY SENSOR LOCATION WITH FURNITURE LAYOUT AND OWNER'S REP PRIOR TO ROUGH —IN OF BACKBOX AND WIRE. 05 ROUTE CONDENSATE PIPING ON PIPE SUPORTS Al' 4—FT INTERVALS AND SPILL IN NEW DRYWELL. ® INSTALL DUCT SMOKE DETECTOR IN SUPPLY DUCT DROP. 70 DUCTWORK OF THIS UNIT STAYS AS IS. ® EXISTING DUCTSMOKE DETECTOR, INSTALL NEW ONE IF NOT THERE OR NOT WORKING PROPERLY. 9O NEW DRYWELL FOR CONDENSATE DRAINS. 10 EXISTING EXHAUST FAN. 11 EXISTING FRESH AIR MAKE UP FAN. 12 NEW FRESH AIR MAKE UP FAN. (SEE ECON AIR SHEETS) 13 VOLUME DAMPER IN EACH BRANCH SUPPLY & RETURN DUCT (TYPICAL THROUGHOUT). LOCATE ABOVE LAY —IN CEILING ONLY. DAMPER TO BE ACCESSIBLE AFTER CONSTRUCTION IS COMPLETED. 14 CONNECT NEW FAN TO EXISTING WALL CAP. O ci Z v O L7 U) w is 0 00 v) v) 9 O _ LLJ N Ln Q (n �' _ � U J O 3 00 Y � � Z OW M d �( 41a�co cn I..1._I w U 0 - w m L N io �c E� t_ Q;a N �ms o ter: � 3a Z .-1 �) 0u�� CAL cq Q t�l Q Q IL « 00 J cll In 'Y Q Q � O v O Q Cl) (]z cv v co L> _1 W U f� - O a `,�S 11li/Af lIII VV DEN No 56189 k O. STATE O 0 H 1(� Hate: 4. 25.22 Checked by: 11 I Drawn: i',►/hli ,lob: 21-04.2 tilu I.1 m 1 01 GENERAL NOTES 1. ALL WORK IS TO COMPLY WITH THE 2017 NATIONAL ELECTRIC CODE AND THE 7TH EDITION, 2020 FLORIDA BUILDING CODE, AND ALL LOCAL CODES OR REGULATIONS THAT MAY APPLY TO THE PROJECT. 2. THE ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR MAKING A SITE VISIT IN ORDER TO IDENTIFY EXISTING CONDITIONS. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THAT ANY ELECTRICAL SYSTEMS TO REMAIN ARE CODE COMPLIANT. 3. THE ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR PROVIDING TEMPORARY POWER AND TEMPORARY LIGHTING AS REQUIRED FOR THE DURATION OF THE PROJECT. 4. THE ELECTRICAL CONTRACTOR IS REQUIRED TO PROVIDE A WORKMANSHIP WARRANTY OVER THE PERIOD OF ONE YEAR AFTER PROJECT COMPLETION THAT IS SUFFICIENT TO COMPLY WITH THE PROJECT CONTRACT. 5. THE ELECTRICAL CONTRACTOR IS TO PROVIDE A COMPLETE SET OF MARKED UP ELECTRICAL "AS BUILT" DRAWINGS TO THE GENERAL CONTRACTOR UPON COMPLETION OF THE PROJECT. 6. THE ELECTRICAL CONTRACTOR IS TO PROVIDE AN OPERATION AND MAINTENANCE MANUAL FOR ALL EQUIPMENT REQUIRING MAINTENANCE ASSOCIATED WITH THE PROJECT. 7. THE ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR COORDINATING ALL WORK WITH OTHER TRADES IN ORDER TO NOT INTERFERE WITH THE OVERALL PROJECT SCHEDULE. 8. IF A DISCREPANCY IS FOUND BETWEEN THE ELECTRICAL PLANS AND THE SPECIFICATIONS, THE MOST STRINGENT REQUIREMENT SHALL GOVERN UNLESS WRITTEN APPROVAL IS GRANTED FROM THE ARCHITECT OR ENGINEER. 9. ALL BREAKER, DISCONNECT AND WIRE SIZING MUST BE CONFIRMED BY THE ELECTRICAL CONTRACTOR PRIOR TO ROUGHIN. SUBMITTALS AND SHOP DRAWINGS 1. PRIOR TO PROCUREMENT, THE CONTRACTOR IS REQUIRED TO PROVIDE SUBMITTALS AND SHOP DRAWINGS TO THE GENERAL CONTRACTOR, ENGINEER, AND ARCHITECT FOR APPROVALS. 2. IT IS THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR TO ENSURE THE SUBMITTED PRODUCTS WILL FORM A COMPLETE, FUNCTIONAL, AND CODE COMPLIANT ELECTRICAL SYSTEM. WIRING AND RACEWAYS 1. NO WIRING IS TO BE SMALLER THAN #12 AWG UNLESS OTHERWISE NOTED. 2. EACH CIRCUIT IS TO BE INSTALLED WITH A DEDICATED NEUTRAL UNLESS OTHERWISE NOTED. 3. THE CONDUCTORS FOR FEEDERS AND BRANCH CIRCUITS COMBINED SHALL BE SIZED FOR A MAXIMUM AT 5% VOLTAGE DROP TOTAL PER FBC C405.5.3. 4. TYPE MC CABLING IS ACCEPTABLE UNLESS PROHIBITED BY THE SPECIFICATIONS OF THE PROJECT, OR THE NATIONAL ELECTRIC CODE DUE TO THE OCCUPANCY TYPE OF THE PROJECT. 5. NONMETALLIC CABLING (ROMEX) SHALL NOT BE USED. 6. ALL WIRING IS TO BE SIZED ACCORDING TO THE NEC. 7. IT IS THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR TO UPSIZE ALL CONDUIT AND WIRING WHEN REQUIRED DUE TO VOLTAGE DROP POSED BY ONSITE CONDITIONS. 8. PROVIDE COMPLETE RACEWAYS FOR ALL SYSTEMS AS REQUIRED BY THE NEC AND LOCAL CODES. TYPE PVC, EMT, AND RMC ARE PERMITTED AS REQUIRED BY THE LOCAL CODE. 9. A GROUND CONDUCTOR IS TO BE SUPPLIED IN ALL RACEWAYS. SIZE THE GROUND CONDUCTOR PER THE NEC, OR AS SHOWN ON THE PLAN, WHICHEVER IS LARGER. 10. RACEWAYS ARE TO BE CONCEALED AND EQUIPMENT IS TO BE FLUSH MOUNTED, UNLESS OTHERWISE NOTED, OR WHEN ONSITE CONDITIONS MAKE CONCEALING OR FLUSH MOUNTING IMPOSSIBLE. 11. WHEN A RACEWAY PENETRATES A FIRE WALL OR FLOOR, THE RACEWAY IS TO BE SEALED IN A MANNER WHICH WILL MAINTAIN THE RATING OF THE WALL OR FLOOR. 12. MINIMUM CONDUIT SIZE IS TO BE 3/4 INCH, UNLESS OTHERWISE NOTED. 13. FLEXIBLE CONDUIT IS ALLOWABLE IN LENGTHS OF G OR LESS, WHEN IT IS MORE PRACTICAL TO MAKE CONNECTIONS TO EQUIPMENT. 14. SEALTITE FLEXIBLE CONDUIT IS TO BE USED IN OUTDOOR APPLICATIONS. 15. THE RACEWAY SYSTEM AS A WHOLE IS REQUIRED TO COMPLY WITH ALL NEC AND LOCAL CODE REQUIREMENTS. GROUNDING 1. THE ELECTRICAL SYSTEM IS TO BE GROUNDED IN ITS ENTIRETY PER THE NEC. 2. THE TELEPHONE / NETWORK BOARD IS TO HAVE NO.6 AWG GROUND WIRE TO THE MAIN SERVICE GROUND. 3. ALL METALLIC EQUIPMENT INCLUDING RACEWAYS, PANELBOARDS, DISCONNECTS, BOXES, ARE TO BE CONNECTED TO THE GROUNDING SYSTEM PER NEC REQUIREMENTS. 4. THE SERVICE GROUND IS TO BE SIZED ACCORDING TO NEC REQUIREMENTS AND IS TO BE CONNECTED TO BUILDING STEEL, COLD WATER PIPING, CONCRETE ENCASED STEEL, AND GAS PIPING IF REQUIRED. DEVICES 1. LIGHT SWITCHES ARE TO BE MOUNTED 48 INCHES ABOVE FINISHED FLOOR TO THE TOP OF THE DEVICE, UNLESS OTHERWISE NOTED. 2. RECEPTACLES ARE TO BE MOUNTED 18 INCHES ABOVE FINISHED FLOOR TO THE CENTERLINE OF THE DEVICE, UNLESS OTHERWISE NOTED. 3. THE COLOR AND STYLE OF OUTLETS AND SWITCHES ARE TO BE DETERMINED BY THE CLIENT. 4. RECEPTACLES ARE TO BE GFCI TYPE WHERE NOTED. 5. RECEPTACLES ARE TO BE SWITCHED TO COMPLY WITH FLORIDA BUILDING CODE ENERGY REGULATIONS WHERE REQUIRED. 6. RECEPTACLES AND SWITCHES ARE TO BE FLUSH MOUNTED UNLESS OTHERWISE NOTED. 7. IT IS THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR TO ENSURE COMPATIBILITY OF SPECIAL RECEPTACLES WITH THE EQUIPMENT THEY ARE INTENDED TO SERVE. 8. ALL EXTERIOR RECEPTACLES AND RECEPTACLES SUBJECT TO MOISTURE MUST BE OF GFCI TYPE REGARDLESS OF THE TYPE SHOWN ON THE ELECTRICAL PLANS. 9. ALL EXTERIOR RECEPTACLES AND SWITCHES ARE REQUIRED TO BE INSTALLED WITH WEATHERPROOF "IN USE" TYPE COVERS. 10. DEVICES ARE SHOWN ON THE ELECTRICAL PLANS FOR A REFERENCE LOCATION ONLY. COORDINATE EXACT LOCATION WITH ARCHITECTURAL PLANS AND OTHER TRADES. NOTE ANY CHANGES ON THE "AS BUILT" SET OF ELECTRICAL PLANS. SWITCHGEAR 1. PANELBOARDS AND LOAD CENTERS ARE TO BE SQUARE D OR APPROVED EQUAL. 2. PANELBOARDS AND LOAD CENTERS ARE TO BE PROVIDED WITH TRANSIENT VOLTAGE SURGE SUPPRESSION AS DESCRIBED IN THE ELECTRICAL PLANS. 3. DISCONNECTS ARE TO BE HEAVY DUTY TYPE AND ARE TO BE FUSED WHERE THE EQUIPMENT IS NOT SUPPLIED BY THE APPROPRIATE BREAKER. 4. ALL NEW BREAKERS ADDED TO EXISTING PANELS ARE TO MATCH THE EXISTING PANEL MANUFACTURER AND AIC RATING OF THE EXISTING BREAKERS. 5. THE LOCATIONS OF ALL SWITCHGEAR, PANELS, DISCONNECTS, MCC'S, ETC. IS APPROXIMATE. CONSULT OWNER PRIOR TO ROUGH IN OF EQUIPMENT. 6. PROVIDE TYPED PANEL SCHEDULES/DIRECTORIES FOR ALL PANELS UPON COMPLETION OF THE PROJECT. ENSURE THAT THE SCHEDULES PROVIDED REFLECT THE "AS BUILT" CONDITION AND ARE NOT SIMPLY COPIES OF THE PANEL SCHEDULES FROM THESE PLANS. IF AN EXISTING PANEL IS MODIFIED, IT IS ACCEPTABLE TO ADD THE MODIFICATION TO THE EXISTING SCHEDULE IN THE MANNER THE EXISTING SCHEDULE WAS ORIGINALLY CREATED. 7. PROVIDE ENGRAVED PLASTIC LAMINATE NAME TAGS ON THE FRONT OF ALL PANELS, DISCONNECTS, TRANSFORMERS AND OTHER SWITCHGEAR. LABEL THE EQUIPMENT TO MATCH THE AS BUILT DRAWINGS TO ENSURE MAINTENANCE PERSONNEL ARE PROVIDED THE INFORMATION THEY NEED TO QUICKLY IDENTIFY THE ELECTRICAL SYSTEM. 8. PROVIDE ALL OTHER IDENTIFICATION AS REQUIRED PER ANSI, NEC, AND ANY OTHER APPLICABLE STANDARDS / SPECIFICATIONS. 9. IT IS THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR TO VERIFY ALL NEC CLEARANCE REQUIREMENTS ARE MET BEFORE THE ROUGH -IN OF ANY EQUIPMENT. THE LAYOUT OF SWITCHGEAR AND OTHER EQUIPMENT ON THE PLANS IS DIAGRAMMATTCAL ONLY. LIGHTING 1. CONNECT ALL EXIT SIGNS, EGRESS FIXTURES, AND NIGHT LIGHTS ON THE UNSWITCHED LEG OF A LOCAL LIGHTING CIRCUIT. 2. MINIMUM EMERGENCY ILLUMINATION OF 1 FOOTCANDLE AT FLOOR LEVEL ALONG THE PATH OF EGRESS FOR 90 MINUTES IS REQUIRED. EMERGENCY LIGHTING FIXTURES SHALL BE ARRANGED BY THE CONTRACTOR TO ACCOMPLISH THIS REQUIREMENT. 3. REFER TO THE ARCHITECTURAL CEILING PLAN FOR EXACT FIXTURE LOCATIONS. 4. MULTIPLE FIXTURES MAY HAVE OPTIONS FOR MOUNTING IN GRID, OR DRYWALL CEILINGS. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO ENSURE THE PROPER MOUNTING HARDWARE AND TRIM PIECES ARE ORDERED BASED ON THE CEILING TYPES SHOWN IN THE ARCHITECTURAL PLANS. 5. ALL FIXTURES AND CONTROLS ARE FURNISHED AND INSTALLED BY THE ELECTRICAL CONTRACTOR, UNLESS OTHERWISE NOTED. PROFESSIONAL STATEMENT TO THE BEST OF THE ENGINEER'S KNOWLEDGE, THE PLANS AND SPECIFICATIONS COMPLY WITH THE APPLICABLE MINIMUM BUILDING CODES AND THE APPLICABLE FIRE SAFETY STANDARDS AS DETERMINED BY THE LOCAL AUTHORITY IN ACCORDANCE WITH FLORIDA STATUTES. ABBREVIATIONS AFC - AVAILABLE FAULT CURRENT AFF - ABOVE FINISHED FLOOR AHU - AIR HANDLING UNIT BFG - BELOW FINISHED GRADE C - CONDUIT CW - COOL WHITE CU - CONDENSING UNIT CKT - CIRCUIT DACP - DOOR ALARM CONTROL PANEL DN -DOWN EF - EXHAUST FAN EG - EQUIPMENT GROUND ENCL -ENCLOSURE EWC - ELECTRIC WATER COOLER EWH - ELECTRIC WATER HEATER ETR - EXISTING TO REMAIN PNL - PANEL EOP - EDGE OF PAVEMENT EXP - EXPLOSION PROOF FCU - FAN COIL UNIT FHP - FRACTIONAL HORSE POWER FLA - FULL LOAD AMPERES G -GROUND GFCI - GROUND FAULT CIRCUIT INTERRUPTER HID - HIGH INTENSITY DISCHARGE HORIZ - HORIZONTAL IG - ISOLATED GROUND LW - LIGHT WHITE HP - HORSEPOWER / HEAT PUMP HVAC - HEATING, VENTILATING, AIR CONDITIONING JB - JUNCTION BOX LRA - LOCKED ROTOR AMPERES MCB - MAIN CIRCUIT BREAKER MLO - MAIN LUGS ONLY N -NEUTRAL NL - NIGHT LIGHT OB - OUTLET BOX PB - PULL BOX, PUSHBUTTON PS - PAY STATION RECEPT -RECEPTACLE SF - SUPPLY FAN SPEC - SPECIFICATIONS SPD - SURGE PROTECTION DEVICE SWECS - SMOKE WARNING EMERGENCY CALL SYSTEM TL - TWISTLOCK TTB - TELEPHONE TERMINAL BOARD TVTB - TELEVISION TERMINAL BOARD VERT - VERTICAL WM - WATT MISER WP - WEATHERPROOF WW - WARM WHITE XFMR - TRANSFORMER LEGEND SYMBOL DESCRIPTION PANELBOARD. 120/208V OR 120/MV DISCONNECT SWITCH 1�c DUPLEX RECEPTACLE. 125V, 15A COUNTER HEIGHT DUPLEX RECEPTACLE. 125V,15A ® SPECIAL PURPOSE RECEPTACLE ® EXIT FIXTURE EMERGENCY EXIT COMBINATION FIXTURE EMERGENCY FIXTURE p REMOTE EMERGENCY HEAD PENDENT FIXTURE O 6" DOWNLIGHT (RECESSED) Q2x4 LAY -IN FIXTURE $ SINGLE -POLE SWITCH $A DMAER SWITCH $W LOW VOLTAGE SWITCH OCCUPANCY SENSOR SWITCH qp POWERPACK ® OCCUPANCY SENSOR Q LOW VOLTAGE DUPLEX RECEPTACLE . LOW VOLTAGE DUPLEX RECEPTACLE (COUNTER HEIGHT) 0 EXHAUSTFAN G3 RECIRCULATING PUMP GFCI GFCl/WP ETR HS SW F GROUND FAULT CIRCUIT INTERRUPTER WEATHER PROOF / GROUND FAULT EXISTING TO REMAIN HALF SWITCH RECEPTACLE SWITCHED RECEPTACLE FLUSH W/ FLOOR RECEPTACLE O©� REFERS TO LIKE NUMBER KEY NOTES UL SYSTEM No. WL1001 (FORMERLY SYSTEM No. 147) 7' RATING -1, 2, 3, AND 4 HR. (SEE ITEM 2 AND 3) 'T' RATING - 0, 1, 2, 3, AND 4 HR. (SEE ITEM 3) SECTION A -A 1. WALL ASSEMBLY- THE 1, 2, 3, OR 4 HOUR FIRE -RATED GYPSUM WALLBOARD/STUD WALL ASSEMBLY SHALL BE CONSTRUCTED OF THE MATERIALS AND IN THE MANNER DESCRIBED IN THE INDIVIDUAL U300 OR U400 SERIES WALL OR PARTITION DESIGN IN THE UL FIRE RESISTANCE DIRECTORY AND SHALL INCLUDE THE FOLLOWING CONSTRUCTION FEATURES. a. STUDS - WALL FRAMING MAY CONSIST OF EITHER WOOD STUDS OR STEEL CHANNEL STUDS. WOOD STUDS CONSIST OF NOMINAL 2" x 4" LUMBER SPACED 16 INCHES O.C. WITH NOMINAL 2" x 4" LUMBER END PLATES AND CROSS BRACES. STEEL STUDS TO BE MIN. 3-50 WIDE BY 1-3/8" DEEP CHANNELS SPACED MAX. 24" O.C. b. WALLBOARD GYPSUM -X' OR X' THICK, 4 FT WIDE WITH SQUARE OR TAPERED EDGES. THE GYPSUM WALLBOARD TYPE, THICKNESS, NUMBER OF LAYERS, FASTENER TYPE AND SHEET ORIENTATION SHALL BE AS SPECIFIED IN THE INDIVIDUAL U300 OR U400 SERIES DESIGN IN THE UL FIRE RESISTANCE DIRECTORY. MAX DIAMETER OF OPENING IS 13)P. 2. PIPE OR CONDUIT - NOMINAL 12" DIA (OR SMALLER) SCHEDULE 10 (OR HEAVIER) STEEL CONDUIT; NOM. 4" DIAMETER (OR SMALLER) STEEL ELECTRICAL CONDUIT MECHANICAL ORTYPE L (OR HEAVIER) COPPER TUBING OR NOM. V DIA (OR SMALLER) FLEXIBLE STEEL CONDUIT. 3. FILL, VOID OR CAVITY MATERIALS - CAULK - CAULK FILL MATERIAL INSTALLED TO COMPLETELY FILL ANNULAR SPACE BETWEEN PIPE OR CONDUIT AND GYPSUM WALLBOARD AND W/ A MIN. y" DIA. BEAD OF CAULK APPLIED TO PERIMETER OF PIPE OR CONDUIT AT ITS EGRESS FROM THE WALL. CAULK INSTALLED SYMMETRICALLY ON BOTH SIDES OF WALL ASSEMBLY. THE HOURLY "F" RATING OF THE FIRESTOP SYSTEM IS DEPENDENT UPON THE HOURLY FIRE RATING OF THE WALL ASSEMBLY IN WHICH IT IS INSTALLED AS SHOWN IN THE FOLLOWING TABLE. THE HOURLY "T' RATING OF THE FIRESTOP SYSTEM IS DEPENDENT UPON THE TYPE OR SIZE OF THE PIPE OR CONDUIT AND THE HOURLY FIRE RATING OF THE WALL ASSEMBLY IN WHICH IT IS INSTALLED AS TABULATED BELOW: MAX PIPE OR CONDUIT (DIA IN.) ANNULAR SPACE "F" RATING ,r RATING 1 IN. 0 TO % IN. 1 OR 2 0+, 1 OR 2 41N. 1/4TO1/2 30R4 30R4 4 IN. 0 TO 1/4 1 OR 2 0 4 IN. 1/4 TO 1/2 3 OR 4 0 4 IN. 3/16 TO 3/8 1 OR 2 0 + WHEN COPPER IS USED, "T" RATING IS 0 H. MINNESOTA MINING & MFG. CO. - TYPES CP-25 S/L, CP-25 N/S, CP-25 WB, CP-25 WB+ " BEARING THE UL CLASSIFICATION MARKING �1� 1.2• 3.4 HOUR FIRE RATED GYP. / STUD WALL ASSEMBLY SCALE = NONE UL SYSTEM No. CAJ1012 (FORMERLY SYSTEM No. 129) "F" RATING -1 HR. 'T' RATING - 0 HR. "L" RATING AT AMBIENT - LESS THEN 1 CFM/SQ. FT. (SEE ITEM 4) "L" RATING AT 400 F - LESS THEN 1 CFM/SQ. FT. (SEE ITEM 4) SECTION A -A SECTION A -A 1. FLOOR OR WALL ASSEMBLY - MIN. 5" THICK REINFORCED NORMAL WEIGHT (100-150 pof) CONCRETE. WALL MAY ALSO BE CONSTRUCTED OF ANY UL CLASSIFIED CONCRETE BLOCKS". MAX. DIAMETER OF OPENING IS 6 INCHES. SEE CONCRETE BLOCKS (CAZT) CATEGORY IN THE FIRE RESISTANCE DIRECTORY FOR NAMES OF MANUFACTURERS. 2. THROUGH - PENETRANTS - ONE METALLIC PIPE OR CONDUIT TO BE CENTERED WITHIN FIRESTOP SYSTEM. A NOM ANNULAR SPACE OF 3/4" IS REQUIRED WITHIN THE FIRESTOP SYSTEM, PIPE OR CONDUIT TO BE RIGIDLY SUPPORTED ON BOTH SIDES OF THE FLOOR OR WALL ASSEMBLY. THE FOLLOWING TYPES AND SIZES OF METALLIC PIPES OR CONDUITS MAY BE USED: a. STEEL PIPE - NOM 4" DIA (OR SMALLER) SCHEDULE 6 (OR HEAVIER) STEEL PIPE. b. CONDUIT - NOM 4" DIA (OR SMALLER) STEEL ELECTRICAL METALLIC TUBING OR STEEL CONDUIT. 3. PACKING MATERIAL - MIN 3" THICKNESS OF MIN 4 PCF MINERAL WOOL BATT INSULATION FIRMLY PACKED INTO OPENING AS A PERMANENT FORM. PACKING MATERIAL TO BE RECESSED FROM TOP SURFACE OF FLOOR AS REQUIRED TO ACCOMMODATE THE REQUIRED THICKNESS FILL MATERIAL. PACKING MATERIAL TO BE CENTERED IN WALLS MID -DEPTH AND RECESSED TO ALLOW FOR INSULATION OF FILL MATERIAL. 4. FILL, VOID OR CAVITY MATERIAL' - SEALANT OR FOAM - MIN 1/2" THCKNESS OF FILL MATERIAL APPLIED WITHIN ANNULUS, FLUSH WITH TOP SURFACE OF FLOOR. IN WALLS, FILL MATERIAL TO BE APPLIED ON EACH SIDE OF PACKING MATERIAL. FOAMED SILICONE TO BE INSTALLED AS DESCRIBED IN THE MANUFACTURER'S APPLICATION INSTRUCTIONS AT A DENSITY OF 14 pa MIN TO 21 pcf MAX. THE THICKNESS OF FILL MATERIAL IS DEPENDANT UPON THE TYPE OF FILL MATERIAL AS SHOWN IN THE TABLE BELOW: FILL MATERIAL IDENTIFICATION MIN. THK OF FILL MATERIAL, in. TYPE F8-2001 1 TYPE FB-2000 OR FB-2003 1/2 MINNESOTA MINING & MFG Co. - TYPES FB-2000, FB-2000+, FB-2001, FB-2003 (FLOORS ONLY). (NOTE: L RATINGS APPLY ONLY WHEN FB-2000+ IS USED.) BEARING THE UL CLASSIFICATION MARKING _T')i 1 HOUR FIRE RATED MASONRY FLOOR / WALL F.n n j SCALE = NONE ALIGN HORN ONLY DEVICE WITH TOP OF DOOR FRAME, STOBE OR HORN/STROBE DEVICE 80" AFF TO BOTTOM OF STROBE LENS FIRE ALARM HORN ONLY, 1 STROBE OR HORN/STROBE, PAINT TO MATCH WALL I 2" ABOVE BACKSPLASH ALIGN WHEN ON SAME WALL � W 4" ABOVE COUNTER `A' A FIRE ALARM PULL STATION W/O BACKSPLASH L iooi o m ® Q 0 0 30 0 CABINET rQy 7 (TYP.) ��o P 0010 FINISHED FLOOR NOTES: 1. MOUNTING HEIGHTS SHOWN ARE FROM FINISHED FLOOR (A.F.F.), UNLESS OTHERWISE NOTED. 2. LOCATIONS OF OUTLETS SHOWN ON ARCHITECTURAL ELEVATIONS SHALL TAKE PRECEDENCE OVER THESE MOUNTING HEIGHTS. FIELD LOCATE OUTLETS WITH ARCHITECT DURING ROUGH -IN. 3. INSTALL OUTLETS THAT ARE IN CLOSE PROXIMITY ON THE SAME CENTERLINE, OUTLETS THAT ARE WITHIN 2'-0" HORIZONTALLY AND WITHIN 1'40" VERTICALLY SHALL BE INSTALLED ON THE SAME HORIZONTAL CENTERLINE LOCATED HALF WAY BETWEEN THE HEIGHTS SHOWN. OUTLETS THAT ARE MORE THAN V-0" APART VERTICALLY SHALL BE INSTALLED ON THE SAME VERTICAL CENTERLINE. 4. VERIFY MOUNTING HEIGHT WITH LOCAL AUTHORITY. 5. ADA REQUIREMENTS SHALL SUPERCEDE STANDARD MOUNTING HEIGHTS WHEN THERE IS A CONFLICT. STANDARD MOUNTING HEIGHTS DETAIL Cam] 1 (PNL) CKT:B-33 St TIMECLOCK MODEL: INTERMATIC T101 INTERNAL NT T OVERRIDE INTERIOR LI SCALE = NONE (PNL) CKT:B-33 (PNL) CKT:B-33 (PNL) CKT:B-35 (PNL) CKT:B-39 SPARE SPARE SPARE SPARE \ j SINGLE POLE SWITCH FOR MANUAL OVERRIDE. LOCATED ADJACENT TO TIMECLOCK AND CONTACTOR. CONTACTOR: SQUARE D 89036 120V CONTROL COIL. ELECTRICALLY HELD. SELECT APPROPRIATE NUMBER OF POLES WHEN ORDERING. L DIAGRAM ° PNL-A- ° 208Y/120V 30 4W -C FED FROM MDP _ikE: 111179 AFC o DINING LAY -INS DINING CANS KITCHEN LAY -INS DINING PENDANTS SPARE SPARE SPARE SPARE -EQUIPMENT NAME AS SPECIFIED ON PLANS -SYSTEM VOLTAGE -UPSTREAM EQUIPMENT SUPPLYING POWER AVAILABLE FAULT CURRENT AT EQUIPMENT -DATE OF FAULT CURRENT CALCULATION 'ALL LABEL AT TOP OF ENCLOSURE 1ALL DISTRIBUTION EQUIPMENT SUCH AS PANELBOARDS, SWITCHBOARDS, DISCONNECTS, TRANSFORMERS, ETC. SHALL BE PROVIDED WITH AN EQUIPMENT LABEL PER THE REQUIREMENTS OF THIS DETAIL. 2. LABELS SHALL BE 2-PLY ENGRAVED PLASTIC LAMINATE WITH BLACK TYPEFACE LETTERS., LABEL BACKGROUND SHALL FOLLOW THE BELOW COLOR SCHEME: a. NORMAL POWER - WHITE b. UPS POWER - BLUE a LIFE SAFETY POWER - YELLOW 3. LABEL MATERIAL SHALL BE DURABLE, UV STABLE, RATED FOR OUTDOOR USE, AND ABRASION RESISTANT. WHERE ATTACHED TO NEMA 4X EQUIPMENT, LABELS SHALL IN ADDITION BE CHEMICAL RESISTANT. 4. LABELS SHALL BE PERMANENTLY ATTACHED TO ENCLOSURE COVER WITH RIVETS UNLESS DOING SO COMPROMISES ITS NEMA / IP RATING. LABELS FOR ENCLOSURES WITH WELDED SEAMS AND GASKETED DOORS SUCH AS THOSE RATED NEMA 12 OR NEMA 4 SHALL BE INSTALLED USING PERMANENT WEATHER-, UV-, AND TEMPERATURE -RESISTANT DOUBLE -SIDED MOUNTING TAPE ONLY. 5. A SUBMITTAL WITH A COMPLETE UST OF EQUIPMENT LABELS SHALL BE PROVIDED FOR ENGINEER APPROVAL PRIOR TO ORDERING. 6. LABELS SHALL INDICATE NO LESS THAN THE FOLLOWING: a. EQUIPMENT NAME. b. THE NOMINAL SYSTEM VOLTAGE WHICH SAID EQUIPMENT IS CONNECTED TO. a THE EQUIPMENT NAME SUPPLYING POWER TO SAID EQUIPMENT. d. THE AVAILABLE FAULT CURRENT AT SAID EQUIPMENT. PANEL LABEL DETAIL GULF COAST ELECTRICAL DESIGN 2111 Sunnydale Blvd. Suite D Clearwater, FL 33765 (727) 330-4937 1 www.GCElectdcaiDesign.com Florida Board of Professional Engineers #33905 A. ,� 0� ••••••••"7s �I 0 80 7 :9% AEOF "Its in R%1110 GIIIIIII z L- 0 b- j� C E w A CL CL .rib a K%�ga 14 r-I Z ,n Tj � 5 00 J lL_ < d C� IL W h N 9 A E � Seal Andrew Z. Pavalis State of Florida License 096063 Date: 2.9. 22 Checked by: AZP Drawn: MAH Job: 21-042 Sheet EO*O 0 (ON ROOF) ICED-2 (CN ROOF) IE� MA-2- XN ROOF) en Al WA4 CKT:B-30 A O _ II III I III I � II III III I c�t:6-� I I Ill III I CKT.B-31 I I III III I I CKT:B-22 I CKT:6-24 7 CH �KT.B-29 ELECTRICAL ROUGH -IN SCHEDULE ITEM NO QTY. DESCRIPTION p c> O > a ELECTRICAL REMARKS 1 1 INSECT CONTROL FAN DIRECT 120 1 4.3 - 1/2 4 1 REFRIGERATOR, REACH -IN CORD & PLUG 120 1 5.5 - 1/4 7 1 SLICER CORD & PLUG 120 1 5.2 - 1/3 18 1 COFFEE WARMER CORD & PLUG 120 1 8.6 1.8 - 20 2 WAFFLE MAKER CORD & PLUG 120 1 15.0 - - 22 1 REFRIGERATOR, SALAD / SANDWICH CORD & PLUG 120 1 7.0 - 1/4 24 1 CONVEYOR TOASTER CORD & PLUG 120 1 15.5 2.6 - 26 1 MICROWAVE OVEN CORD & PLUG 120 1 20.0 1.8 - 33 1 FIRE SUPPRESSION SYSTEM DIRECT 120 1 1 6.0 1 - - 38 1 GRIDDLE 60", GAS COUNTERTOP CORD & PLUG 120 1 - - - 40 1 GRIDDLE 36", GAS COUNTERTOP CORD & PLUG 120 1 - - - 41 1 FREEZER, REACH -IN CORD & PLUG 120 1 10.5 - 3/4 49 1 DISHWASHER, DOOR -TYPE CORD & PLUG 120 1 12.0 - 3/4 55 1 ICE CUBER DIRECT 209 1 17.1 - - WATER FROM FILTER 56 1 REFRIGERATOR, U/COUNTER 2-SECTION DIRECT 120 1 2.0 1.0 - 57 1 SOUP KETTLE WARMER CORD & PLUG 120 1 4.0 - - 59 1 TEA BREWER CORD & PLUG 120 1 15.0 1.8 - 60 1 REFRIGERATOR, MERCHANDISER CORD & PLUG 120 1 9.6 - 1/2 61 1 FREESTANDING ICE BIN W/SODA TOWER CORD & PLUG 120 1 2.0 - - CORD & PLUG 120 1 6.0 - - 62 1 ICARBONATER CORD & PLUG 120 1 7.0 - 1/3 63 1 1 CASH REGISTER TERMINAL CORD & PLUG 120 1 4.0 - - NOTES: 1. ELECTRICAL CONTRACTOR IS TO REFER TO ARCHITECTURAL AND FOOD SERVICE DRAWINGS FOR REQUIRED ELEVATIONS OF DEVICES AND JUNCTION BOXES. 2. ELECTRICAL CONTRACTOR IS TO CONFIRM VOLTAGE, AMPERAGE AND CONNECTION REQUIREMENTS WITH FOOD SERVICE DRAWINGS PRIOR TO ELECTRICAL ROUGH -IN. I III � � III III II �' I I III I III I I III II ca I III III III II I ( III I I III I I III I II � II III ( III I III I � II �I � II III III III II II-'- -�-' EXISTING BUSS STATII CKT:B-31 KEY AREA NOT IN SCOPE GCFI 00 t o STAINLESS STEEL PLATE DIST. A.F.F. FOOD SERVICE RECEPTACLE MOUNT RECEPTACLES HORIZONTALLY IN FOOD SERVICE AREAS DEMO NOTE: ELECTRICAL CONTRACTOR SHALL SAFE -OFF ANY ELECTRICAL WIRING WHEN DEVICE OR KITCHEN EQUIPMENT HAS BEEN RELOCATED, NOTES: 1. ELECTRICAL CONTRACTOR SHALL MAKE ALL FINAL CONNECTIONS TO KITCHEN EQUIPMENT. 2. ALL HARDWIRED CONNECTIONS TO BE MADE WITH SEAL -TIGHT FLEXIBLE METAL CONDUIT AND WITH PHASE AND NEUTRAL CONDUCTORS. GROUND WIRE TO BE BONDED AT BOTH ENDS. 3. ELECTRICAL CONTRACTOR SHALL VERIFY ALL EQUIPMENT REQUIREMENTS (INCLUDING THOSE SCHEDULED) WITH SUPPLIER PRIOR TO ROUGH -IN. 4. ALL (15A) AND (20A), 120V RECEPTACLES IN KITCHEN SHALL BE GFCI PROTECTED. SYMBOL KEY RECEPTACLE PROTECTED BY GFCI CIRCUIT BREAKER TYP. IN KITCHENBAR AREAS) EE PANEL SCHEDULE O POWER KEYED NOTES: 1. NEW 120/208V, 3-PHASE, 200A, MLO, 60CKT PANEL "B". 2. EXISTING 120/208V, 3-PHASE, PANEL "A", TO REMAIN. CIRCUITING EXAMPLE KEY CKT:,4 a DENOTES LIGHTING SWITCH LEG DENOTES PANEL NAME (BY ROOM). LIGHTING PLAN ONLY DENOTES CIRCUIT NUMBER DISCONNECT EXAMPLE KEY 0� 3 NUMBER OF POLES NEMA WEATHER RATING DISCONNECT RATING FUSE SIZE ("NF" DENOTES NON -FUSED) GULF COAST ELECTRICAL DESIGN 2111 Sunnydale Blvd. Suite D Clearwater, FL 33765 (727) 330-4937 1 www.GCElectdcaiDesign.com Florida Board of Professional Engineers #33905 o....•• (.�••���4 .••�C E N S :rS • 80 7 !, . , ap. • It. pi AT OF �i��;60- 4.O R 1 ID N % OOZ4' ONA1. rE 111 GORY A GLASS P.E. #80467 r_F' POWER PLAN O 2' 4' 8' qL-01)SCALE: 1/4" = 1'-0" scale: 1/4" - I' -a' Cr W Z :0 0 ONO" O �- w o r L . a 10 � 3 a V4-1 a s a 1I1� LLllll!!!� p N d' r-1 z I't o �� ~ Q o+-COO J Q In r-I Q OL (0 m w O N CL v W ti Seal Andrew Z. Pavalis State of Florida Licenae •96069 Date: 2.9. 22 Checked by: AZP Drawn: MAH Job: 21-042 Sheet El 90 i 4 ER ) ER LIGHTING CONTROL SCHEDULE DESIGNATION DESCRIPTION MANUFACTURER CATALOG # VOLTAGE NOTES WALL MOUNT LINE VOLTAGE VACANCY SENSOR ACUITY WSX PDT SA WH 120 --- LIGHT FIXTURE SCHEDULE DESIGNATION DESCRIPTION MANUFACTURER CATALOG # VOLTAGE WATTS TEMPERATURE DIMMING FINISH LAMPS LENS NOTES A EPANEL LED 2x4 LITHONIA EPANL 2X4 4000LM 80CRI 35K MIN10 MVOLT 120 38 4000K 0-10V WHITE LED -- --- B LED PENDANT LITHONIA EML17 ST 49LED 350MA 4K GCF R3 MVOLT DDB)D 120 59 4000K --- DARK BRONZE LED --- -- C 6" DOWNLIGHT (RECESSED) LITHONIA LDN6 40/10 L06AR LSS MVOLT EZ10 120 11 4000K 0-10V --- LED --- --- D CEILING FAN --- --- 120 150 --- --- -- LED --- OWNER PROVIDED EMEX 90 MIN. EMERGENCY/EXIT COMBO LITHONIA LHQM LED R 120 4.3 -- NONE WHITE (RED LETTERS) LED --- --- EM 90 MIN. EMERGENCY LITHONIA ELM41, 120 3.15 -- NONE WHITE LED --- --- ER REMOTE HEAD LITHONIA AFO W MVOLT N SD 120 1.5 -- NONE --- LED --- WEATHERPROOF 0 LIGHTING KEYED NOTES: 1. CONNECT TO NEAREST "CONSTANT HOT" POWER SOURCE. USE LIGHTING CIRCUIT ONLY. 2. EXHAUST FAN CONTROLLED ON/OFF WITH LIGHTS IN RESTROOM VIA OCCUPANCY SENSOR. 3. REPLACE -IN -PLACE EXISTING FLUORESCENT FIXTURE WITH NEW LED FLAT PANEL FIXTURE. MAKE: LITHONIA MODEL: EPANL 2X4 4000LM 80CRI 35K MIN10 MVOLT. USE EXISTING LIGHTING CIRCUITS. PANEL LOAD SHALL REDUCE WHEN USING LED FIXTURES. CIRCUITING EXAMPLE KEY DENOTES LIGHTING SWITCH LEG DENOTES PANEL NAME (BY ROOM). LIGHTING PLAN ONLY DENOTES CIRCUIT NUMBER TYPICAL LIGHTING CIRCUIT AND SWITCHLEG KEY Fixt ue CAPITOL LETTER DENOTES FIXTURE TYPE CIRCUIT (Constant hot provided to power pack) PANEL NAME Pow k CKT B 3 LOWERCASE LETTER DENOTES SWITCHLEG GULF COAST ELECTRICAL DESIGN 2111 Sunnydale Blvd. Suite D Clearwater, FL 33765 (727) 330-4937 I www.GCElectHcolDesign.com Florida Board of Professional Engineers #33905 ,,����I11/11111 �`•`,p4;; • A. G44 go w • � A E O k,S,/0IVA� CORY A GLASS P.E. #80467 1 LIGHTING PLAN o 21 41 81 Ei2 0 SCALE: 1/4" = P-0" Scale: 114" = V-U ONIIIII Kr c9 W Z o cE w o UaI # cr A a� o� h lilt z � o<J< 0 O O Q d 4-)IL DZ L0 W N 0 Seal Andrew Z. Pavalis State of Florida License 096063 Date: 2.9. 22 Checked by: AZP Drawn: MAH Job: 21-042 Sheet E 2. 0 4 i Ll PANEL B EXISTING FLUSH MOvrn'm 120/208 VOLT 3 PHASE 4 WIRE WITH GROUND 200A MLO NEMA 1 NOTES CKT. DESCRIPTION BREAKER A B C BREAKER DESCRIPTION CKT. NOTES NO. TRIP POLE VOLT VOLT POLE TRIP NO. 5 1 [11 INSECT CONTROL FAN 1 20 1 120 516 1 180 120 1 20 38 60" GAS GRIDDLE 1 2 7 7 31 141REACH-IN FRIDGE 1 20 1 120 660 1 180 120 1 20 1 L40136" GAS CPMDLE 1 4 7 7 5 171 SLICER 1 20 1 1 120 624 1 1260 120 1 20 1 1411REACH-IN FREEZER 1 6 7 7 7 [181 COFFEEWARMER 1 20 1 1 120 1032 1440 120 1 20 1 [491 DISHWASHER 1 8 7 7 9 1201 WAFFLE MAKER 1 20 1 120 1800 1 1779 208 2 20 1 [551 ICECUBER 1 10 7 7 11 [221 SALAD FRIDGE 1 20 1 120 840 1 1779 208 2 20 12 7 7 131 [241 CONVEYOR TOASTER 1 20 1 120 1860 240 120 1 20 56 U / C FRIDGE 1 14 7 7 15 [261 MICROWAVE 1 20 1 120 2400 480 120 1 20 L571 SOUP KETTLE WARMER 1 16 7 7 17 L331 FIRE SUPRSN SYSTEM 1 20 1 120 720 1 1800 120 1 20 1591 TEA BREWER 1 18 7 3 19 RTU-4 45 3 208 1 4680 1 1152 120 1 20 60 FRIDGE, MERCHANDISER 1 20 7 3 21 45 3 208 4680 240 120 1 20 61 ICE BIN 1 22 7 3 23 45 3 208 4680 1 720 120 1 20 [611 SODA TOWER(1) 241 7 2 25 RECEP - OFFICE 20 1 120 720 1 840 120 1 20 [621 CARBONATOR 1 261 7 2 27 RECEP - BOH 20 1 120 540 480 1M 1 20 [631 REGISTER/COUNTER 1 281 7 2 29 RDCEP - BOH 20 1 120 1080 1 100 120 1 20 RECIR PUMP -i 301 5 2 311 RECEP - FOH 20 1 120 360 1 3120 208 2 30 WATER HEATER 32 5 1 33 LTG- FOH 20 1 120 408 3120 208 2 30 34 5 1 35 LTG-BOH 20 1 120 383 1 312 208 3 15 KEF-2 36 6 2 37 RECEP - OFFICE 20 1 120 540 1 312 208 3 15 38 6 1 39 LTG- FOH PENDANTS 20 1 120 1239 312 208 3 15 401 6 1 41 CEILING FANS 20 1 120 900 1 384 208 3 15 MUA-2 42 6 1 43 HOOD LIGHTS 20 1 120 360 1 384 208 3 15 44 6 45 384 208 3 15 46 6 47 48 49 50 51 1 52 53 54 55 208 3 30 SPD 56 57 208 3 30 58 591 208 3 30 60 CONNECTED VA SYSTEM VOLTS PHASE AMPS 17736 187021 15582 120✓208V, 3 PHASE I NOTES ( ) 148 156 130 CONNECTED NEC DEMAND DEMAND LOAD (1) PROVmE G Fa BREAKEIL 3290 1.25 4112.5 VA 3240 1 3240 VA 14040 1 14040 VA 0 0 0 VA 6856 1 6856 VA 2088 1.25 2610 VA 22506 0.65 14628.9 VA TOTAL 45487 VA 120/2WV, 3 PHASE 126 AMP NOTES LOAD TYPE IS LARGER 1 LIC HTING 2 RECEPTACLES 3 AIR CONDITIONING 4 HEATING 5 MISC. NON -CONTINUOUS 6 CONTINUOUS 7 KITCHEN THIS PANEL B IS TO REPLACE AN EXISTING PANEL THAT IS OF SAME AMPACITY (200 AMPS) BUT DOES NOT HAVE THE REQUIRED NUMBER OF CIRCUITS. THE AIC RATING OF THIS NEW PANEL B IS TO MATCH OR EXCEED THE RATING OF THE EXISTING PANEL THAT IT IS TO REPLACE. KITCHEN EQUIPMENT CIRCUIT EXAMPLE KEY [ 1 ] CHECK PRINTER K(2) EQUIPMENT NAME ANEL SCHEDULE NOTE TIKITCHEN EQUIPMENT ITEM NUMBER ANSUL SHUTDOWN DETAIL: MAIN HOOD (KEF-1, KEF-2, MUA-1) TURN OFF: • RECEPTACLES UNDER HOOD : B-38, B40 • MUA-2 • LIGHTS CKT:B-38 CKT:B-40 HOOD CONTROLLER TERMINAL HOOD CONTROLLER TERMINAL NEW CONTACTOR ELECTRICAL CONTRACTOR RESP. HOOD NOTES: 1. RUN WIRING TO GAS SOLENOID FROM CONTROL PANEL AS SHOWN "ECON-AIR" SHOP DRAWING SHEET 6. PANEL TO SHUT GAS VALVE ON FIRE CONDITION. 2. RUN WIRING TO (MUA-1) SHUNT BREAKER (A-23,25,27) FROM TERMINAL "ST" TO BREAKER AND BACK TO "N1" NEUTRAL TERMINAL IN HOOD CONTROLLER. 3. PROVIDE AND INSTALL NEW CONTACTOR TO SHUNT POWER TO RECEPTACLES UNDER HOOD IN FIRE CONDITION. SEE DETAIL BELOW. 4. RUN WIRING FROM CONTROL PANEL TO HOOD LIGHTS. SEE ECON-AIR, SHEET 6 (E500). 5. RUN WIRING TO BOTH RISER DUCT SENSORS. SEE ECON-AIR, SHEET 6 (E500). 6. ALL OTHER "ELECTRICIAN" RESPONSIBILITIES SHOWN ON ECON-AIR SHOP DRAWINGS. EMERO NORMAL NORMALLY NORMALLY OPEN CLOSED 0 INTAKE FAN COMMON HOT--I---O/ 0-- FAN SWITCH EXHAUST FAN NEUTRAL TYPICAL HOOD INTAKE AND EXHAUST INTERLOCK DIAGRAM 1 POWER RISER DIAGRAM SCALE: NONE O POWER RISER KEYED NOTES: 1. NOT IN SCOPE. 2. EXISTING TO REMAIN METER & 120/208V, 3-PHASE, 200A / 200AF NEMA3R DISCONNECT. 3. NEW 120/208V, 3-PHASE, 200A, MLO, 60 CKT, PANEL "B". 4. EXISTING TO REMAIN 200A FEEDER. 5. NEW SURGE PROTECTION DEVICE ADDED TO PANEL 'B". GULF COAST ELECTRICAL DESIGN 2111 Sunnydale Blvd. Suite D Clearwater, FL 33765 (727) 330-4937 1 www.GCElectdcolDesign.com Florida Board of Professional Engineers #33905 CORY A GLASS P.E. #80467 OMIINI z 4— Q J Q Q) A Q Q In O � i 0 J N < pIL �- m w IL N w Seal Andrew Z. Pavalis State of Florida License 096063 Date: 2.9. 22 Checked by: AZP Drawn: MAH Job: 21-042 Sheet E3.0 a" v `4 IA L/THO/V/A L/AGHT//Ya - NrAfAI wwrATION Nam OrdedDtI!!i nUohLPle SensoriwmtchlOT PLOIOIDtCk!Performance DAN Plat" FEATURES & SPECIFICATIONS A NMNOEO ME - The EPANLeeks SLED EdWLh Rat Panel provMn a fully haminc us appa7aa arms the Gar alto lent. This pm toes a salt glare -free solution tot Isvbually Comfat*e within thespau. SwtawformwyAph%gawkaumsbdd m Kho*oAlmarMothmMMMWWspam, .Cl ref Pao cam EPANL LED ty2MSTRIK110N-Bhsl%IAstwNhaakmhNwm haaefa stralgtlt ad dtxaMBty, toseornlemfame plane gMledblecornesThelatAllNgMglMepbteaedkara7bbyeMowkgarMtrasmNaAgM Vx4,YXYand 2* wedsuWwAcKy.ThesOnwWkmpwft"celkmsheAtopandhollykok mappoe m. FPAIR'slox`PraFledetlgnRmvldesYlaewdMsuMMlmAeld6ityespetgRylnrestLkadPksKmspaoK. ,�„�,�„r The bad 00 hdudes longed Tow dial; for Imtallow Moo 1StW K IVIf T-0 cW gs. R ich re m,ybesecesse4wnpended,suAouhamoaatadamlwmedb,oM•cexblpsee,uaxorkssectbn brmaebMrutbn. FhStaem,ytxmKnatdandwkedlncasthllwusrows. 1 , NabgratN S"w boUl t Wbed Ilst%seNmgq This saNpr Is night -amebic, munbg it has the &Wty to communicate am se A* network. When wheel, a" CAT-S ta", with other I Might -tabled semen, power parks, or WAMPods, an relight central am Is Dea%d. Ora Mad to a Gateway, directly or vb a Imldpe, the Uwt becomes capable of nmow suds a*" and contra WaSenwrVkwWtwm. .. _. bNlMWSmM%m OUgltAWVA I Pktfon*TbeRES7mentorbnL4htMRen4led, mare" It has the awty to CommmkAk over the Wheless; m4fit tanrrtl pbt/am. It b avabae with an automatic dbmning phaaall, and either a dgNd PM a a mkrophonks (PDT) dual tedirwlopy occupancysensa.hparstootherlimdnNlbsand waNswNchathrougRowmadka�CIAIARIwhkh ntltiHlr ® � diem for simple sensor wotmem Ia VUW IYkdem senate (aNgN reees aatrdk Seem Switch VERTEX NOT or )OTVTXIS kmdmke-embeddedtanp,ngandamMentlight s"w&mthe lmdnalretopower tDwhenthe ® �• j or *mhwwoplederwhmenougliambkm4MbemKklpthespaa.SeepW7fam mdobon C us 1 tobHegratedwhammsaw. UNTMM-long-WeLEDs, coupled with ahigh-eR cles"Owes, prwvMevvuwRkmmNatbnfor eaterded service ads. See page 3for deaMIuweneWntenencer Isdanmdm.0-10VOwdngddtet dims ton%or10%ant! contaimnon•hoM%ddom"leads. Embed it lght controls today. Prepare for tomorrow. ►MTINBS - CSA (mind to meet US and Canadian standards. Tested to meat ULWA Intended for mdoorweeny.product: brust lobe soWinundmm mtm§WsWmDKlpn Wocomatlum• Now Tomorrow MWPw*mgaRRedprodwadDLC*oMMFueled. Not all veshersdthbpradKtmaybe OLC '-- ft"*WddwDL(quV*&Pkmdtdtt*DLCOvWWh%UuListatwwwdtWnidts.org/` 8 UI 61•ndlyirimll Scd4WIty �L%codamlmWhMlvemdasaregtaMed.Oslmpbntlonlred. Krated. NKXrmd.laganrmmda%re, mAgaabbpredmtbnadforNSFM1I Rpdafd2-UOMTktmfaSpWzomw4NonFtod2°m. Rnhm•d•u4noywrngt O sp*c.C. +puration Tested It aomrdeme with ISO 14644-1; sWUW for ISO Clem 5-9 poYAwand fagpda limm" Men mm.Sunablefile AmbkenttempemwnIom32iE0Y)to77K(2S-C). C.&eompilana M11 Futumready WARRANTY -$-year limited weary, ills Itthemlywananty proWdedand mcuie statemats bthis apKMatbnshorthateanywarranty aamMuddAll other express and I mpodwerrentles am dbclaWW. Cmtpkte wamgwmm bath er terms -all -conditions Nob:Ac%dpuWnwanWditasarmftaend-userarvham MuWappkauon. AM aluenamdes ipsortypkdwlves,meatued mkrbboratayanditbnsst25IC. Wkidmsvi*d%dw WwMownotice. O&WOM iN4 212 he Lenpd 47.72" 23.70' 47.7r Width 11.85' 23.70' 23.70' Depth 2.W 2.W lir Wright 13.911s 1A6s 15.1lbs ' Base anAguratklm; aptbm mayaMwdght 1-i' Capable Luminaire This Rem is a A+capable hNoliwke, Mdddh has been designed and Tested to provide mruistmt cola appeawna and out -of -the -boat &W ompoNky MM SknpkwnNrlksbnMg, • ARcofdigLNadormdlMslumindrerrmettlleAltdryBrands'Sped6catbnM CMDLMDCalmbtency This Ion udre Is part of in A+UdW Solution for nL W control networks when adered with delvers marked by a diiiiiiiiIiiiiiiiiiiiiiallift This hlmlrtake IS part elan A+Cft W solution for W* control networks, providling advarxedl coubrol functionally at it* huninshe level, when selection hldudes delver and caraol options madredd by a To hill more "A A+, vWt www.acufands.com/aplus, *See orderhlg tan for details COMMERCIAL INDOOR EPANL IA L/TH40/V/A L/a mnivdrs ' FEATURES & SPECIFICATIONS am NATW O BSE - MOt for appBatlom ngemp both eel Mp all mN agdpmaM Atlacuw, r all, duw&M dtepn IN g o for a1Nw4 e-dow appk0m and dpM Aar OpMW hgA•aRpa W*A weds range bmps art Mal to tlm%tgemy aptm AgMkmg caeoM aslarw amwdm.b E M E X army da*M hnbgaty ehayk Aamdhr r•UaeYtNAa C/IIMTRBCTION - EnynaeAnp prAM Namopladc am* it bl(la•mbant agwb+aMam all %urots moodlim-proe. mw4 Amw mdng W shun Ram wins discabra , Rom nmwa ad nn•mde ff Q6G�4IY71!' tbmgpd anbedy ablmkq snap topaa with ro,dlWW teatenes Fanpbte and eat aver are has demamble an hou llg, Paton maul tabs held fad 0 sKwiry, yet at any -of'* %I hm0 a? c iig� 1hs11NOpIdtlC Eldls baapaamtaaesW*nrd,tAattloNsldwwaainatsateaAyRMNWKAteimead Y'y .. IhMaalgrapdaNhNMnstmwMaeshadowsahartpastatanat6'hgAwM3N"wroke,wM100R . NawMgsNarana Iatimg bmMupon IA.921ararWard. �• •....,..,~,�' -. A.; ,:... LEUsaaardmpmamwydrtukaamlFagvrWadm,Lela-engy/UDMmphdpnapaaKknanW (L H QM L E D(ACl pet) all mwp gi(DC asps) nwdn Low-prdle, Integrated Rat wvkch/pft light Easily Mewed M * W stew Indicator Wegm�araganmtP�kAanNadlnttlandlapodalmmmamCUMrasal�amt 2. mmundriq patwm. Tod•Na aamm kr mhRnana. Ca """ poaWm onby of wAL Bel, heat Nor $A*,791 MMAM- 0.142,iN 5,71117An: D/n,Xn; 540,251; D4 $=, LED Jy e•j wrsAn;sAn,lal;sA46,m. Nidlel-Gdmlum OPTICS -Twin LED bmphadsassets inamMwy (DC Near) modewish 12u1%s• &Wwhite LEDs badlhut PRvldmiaasrMaMNgMwaasUamNemnagemyOpMNgperbmmnae.lhetygalWed MONO the go LED WR it 10 years, aKTOKAL - Dwl•wil" Ypm apt6Nay (1204M. Edge amain on ph W draft bond waves bq•temduRhMty, Cmmm**M dwprraemhn bowy Nit died ahkems mmrgy mmwnplm. hoWdes low apaaung ma SlavdroMtpnobactbn-MM-ldngdiaprdemkypMMWIMWdrm boWfromkm ThornW mnpemmem +gods Braga oulpat % INtwMe aptbmm dwp reap NWn % ambler RpdaWdwgewa+geaaWdmaaUmtArgeWbgedRraMlRrgealawtmhpesPraanaa, 6 C= f� - WlOhdwg"""-tmbKm &WAlst mopoft a MB., American A1eMdar9mMPutnllYrldymdraegevakeger4Plerdmmndsaapmy'Nit. =� At/LV0 ram Am bear!' annettum before AC pow IN; applied and pmaas batty dotage hoar deg disc arye• dim p lad w odo FOOM Xd w�tle� WROW for � cob). ITeNC a 0 OS besides daMaN & .All all ap�pNRMle rot TO 47, putt IS Solso rt I SdFdlagadlckdlr'9fa30seaMsevay30dps30mMNNl:N110dMMyenaLard90aNwmsamaay. NgWm a Dlpnaocsolution dLED NpMwunaAC-%DChamkLdlarybgaMbe" random III AAIEWAN- Import well the OMpuoait wnaWinthe 0%admwsthe lyAmerce(n) Battery: Sealed, nmbRnana-tea ddra-aaalro be"deNwn 9Mlinsite upadq to wiergal 9 P mowmmunder fill OFAASand WL Raw raw% wwwAcuit&an&.com I+a)m•no-staRamf%rwcurremdragemathN%sbe" NAN and nWAitlnlly' richarps share y ma:amNdanfaManonWkdarnMm. oldtrge.law-vdtaliedlic— poem nmmNeM*dmpditdrel9fgrm%n dM *tMbm- WARRANTY -S-ywM*Wwxmq.(Son4prormed).Thbbthe any mtmgprm'Idedand no IeyOptknahlRMmmpmbatWy%pamerboMladamdoptlaWLEDnfmwOelonp dmmaneaery. moraa%nMam%MNapeLtlallmdRdda%aywaranyaaryalndANmhaapmaadMpNed RMMLLm-Ur"wmaa%gomfatbpaaWmwjntwaatowwbrdrpkbm". tvummmdxww.cwomvmmmyamtbaada Lb%%gapstomMwlthpaMw4Kkhgtfbe.UnrbdappMaamMW"tomW w b* mraMm xft Wadmua,CwA'kmgLerodmrdkrllrb"=WWL OapMmrrmbaaf" No* Actual Witham may Own a resat ofend•useremkamamemWppNtdlon. AAv*mmdtdportypkdvalets,wtasedw4uM ormganft mat25Y. SpedlkNmw*atod pwNoutuua. tEast Slips Catlldbthe (AThis 20Ao norRAdflDmmbme. umm in Y:R7..���Y�•' (-�3�.tjt) ..:,:. f .... •, l'aa3.���1Ji�'�3%"11Mfi7`��a•W'Yi1TL"!uwb»i'Ai?. >�+R'R''�`:,rlRa�'{��� LUNiM ]Stmdixe,drgk ® Two . WMte Red NO Nigh-mtputNl-ud" mom MMUMexkN$tuw s' fxepMbBbd 6 Green NO No No -output NOMSAUDA SdMaSlplagelnon-UU' emafoapm white LED SD SaFdMgnosNa BAA WryAmteko(x1AaComplMbt Waaqueous RMRWI RAW I* EN SOT mAn dadNObeft 7 SwspdmmO -Tali. eager WofUlOMLrobOmWiPW-104'FC2r4VO. a seespKdaisElA:MemhNs I AaAabbakOkddwNLLtaronkfKwryNraplbas 9 Swspa AatfBLWNm�SOTRm usofdm%bx" 3 hyMmbinmkN0lAmrldid Rnpadwe mepof Lrob %a'-MY00'4040• 4 %ImyaNgd" Willi ddlaparwa*Ucwdw(oc Hos) 10 Ngmkbbwbsko*twpaMleWONOWNOAAGPNLWal S wMHDDwHglMwNkSDaPNatSwspcdm FIESOTIaaomsMFdl%bmaLamiarwmewvo(Uod 6 EO�dWyV� NOam%RDe"ka usumd btrMwpbw "-' w61'-101'F QO'•40`G. SKR1KdmdEUMWaOMAI:.La bkrmwaiWaDMNWOP• Tema Sn MpapZfapWoaampL moappaar6atltlqup MWTorOW TRum n its(lRbamA nmupaNmwgnpad1110M labamMdm 6r•104S DOL0'G. EMERGENCY LHOMAED EPANL LED Flat Panel 0 Exid" ,, EPANL2X44000LMEOCRI35KWNiMVOLTEiOWCPNLTMR2MO WSW iiiiii�'lli,iii-imai.ill SfMaMdLIMM1>; E►ANL LED Flat Fiend IN4 11114' 1SOOLM 1SOOLumms 15WMNE 150CLumem FIRM MCW 30K MIT MW10 No to1016t 3000W 30001uman 3000LMNE 300DLumern 3,gpp( MINI Dims to t% 40001M 4MLwdm 4000LMHE 4000Lwmm 40K 4o00K 480KM 4100Lmmms 4100LAINE 411100l.wro m SOK 50001( 6000 6000LVMM 60M MNE 60 Urmens 212 2w, 2"" mum m IO teal MLuman 111101.011 340oLumms 3400LAMIE 3 IAmems 4011101.011 41MIAmms 40DOLMiM 4111elmmm 4a001A1 4OLumen ± 4$DKMHE 4000Lumm iml Ind' WOOLM 3A00Laams 30ORMHE 30001mmns ® 40DDlunmmis 40001MHE 4000Lmmm 1800LM 4000 Lumens 4BOOLMME 48011Lumms mmm SWLumea 540"K Mussel 60DOLM 6WDLumms 60OKAINE 60MLmRns 6BODlA4 6000Lmma 6800lMHE 6BOOLumens rA" I'M m ens 72UMME 72M Lumem 2T weokoiwow" MVOLT 120.2m (Bb* Now E10WCP EMSeN-04lm*bnayped410WComUMPmK,CffdWktCATLHe2pK4Mt V dwof*twgAv 120 120V SLD Sees LOW Mal GM GearamrhamshrDeaat DMI 111111001111111.1 2" 277V ENIG form with NL1GHTorNLTANt2mgelsKotasupplyEMpower t �jj 347 1l347Vt IFcarted beat Ceateel blkllwl Cet lrN OIWAAked; ddLwkdt JOT Wb*umwamrolwM am nllgMelwbled,racantamhmmmalmgensmt (bank) Rom" worwTouch'P+Wngt )O MI5 Wkebsseaupancysmwvo 'latoneToud"pakbg t BLIgbtl6�kss; . Mtlil�t et�gNtYAll6aAeMMat12t1RA1Nta Np p1�Rf+11Uaa16AM,�: N9C7 AUpBBdB1nM6FVN f+RbMtFBITIAI(Iiapp taaasraM i 1 .. ._ � T�.y'� %;.P'.''„ ' .'at{-- 1.,.= y �; . 9N ... .rte-�i -. r�?:l•.- :`1'• 0 Fam-bewhillmet PWSUWV 6'pre-wow,3/rOWmw llgnp ldm*wAow"kWwost 6W Sbw-blo ions CP Cldagopl— PWS1t36 6 pw-w4m, 3/0" &Mft, l/ page, I" IRT Werra FSM MI$46 fpit w6w3A"&TAM,IsPVK2" 0DP FKUryMwhedBMamWsammmectPhlg PWSIB46PNfKV TwouOits:ON6'pre•wke,3R•dla esial1111pKspe,2dxft Ml_ IIE w-mMykimmis et whiclaWWI .0 annewlegnpet NOTE:* Indicate option vOmbnom W" nNk h s. Mom mfmmto Optlm WhwOf&" RKUCWns chat mum ran page. Opow an sorted aowm wrkdy. IA L/T2 aywA Alaw iva- COMMERCIAL INDOOR: One LmhadaWay Conyers, GA 10012 Phone1-8*705-SERV(7378) www.Kunykands.corn IA L/TH40/V/A L/GHT/mv- FEATURES & SPECIFICATIONS INMNREO Bog - kvWn a MNMmm of 90 minutes Mmdnaem for the Mad %MW upon Ias of Al POW to mW*M O MMcode NOW NNW44MW4 Mora forappl Q*m RgWf4 MOW a unit dpliem wn*okwdo=mW1NIpwMWpetanami famotmI h"obem7S'to30.CMAb abMnreaftfeabrmesosdb*AAIM' plgrdaeyllcas17arpattyarbeaeb. CONSipCTION-ilteharrNp isafteiMadwMMe DlhdtaptNNwD Mmmp1%ticwMh a aapaf ad low• W�-daAlt dii�alewtlam0mmnaroR�laMrgMRRb�lpw•pitRle,klagraaA all bWklast wastm With a m aAyMibleaNdd-cdaLED suns Indionclk bad-Owmg*o a universal pbatam" pmentiokditskmwdYaUltleeonawide ""Of)-mmand dwlent homing allows, W04o bomm(oruwamohwame. %a" Me&hmamigmuo"""NMI~ Wf &Mm"OfarKnaof OPTICS -The RKitch"oweMgN W*waraLEDs ratedat33wailsperharphad alldeAvas a ud d w kmms h a spot plmm 15P64K)• The OAK kaxasam jipmknnrmaeLEDs randa53watts WIsepleadand dealer%aWAa1,100 Naas b a spat Patter (5P1100U. Thetypkd Nkdan LED IN 10 Vanilla LED aide saunas typically new Nestle be mplaad tedenoma CaMNbmfanmmW OAppNadofs CCT: Sm rAiCTMtAI-Odaahla b mbMgkN kages (weada'kKnorfar spmlAcvaogm ) Cun-4 k"dagamrdmMesbatteryAbendmWffAzaMamwwfttoEmovkklawWaf corn.Smdbg"dwpisr,-0-'btoCATAkmAppb=EaWMDat m. Short-circuitP-Mnem4knNMpdfM9orelmWypekctsPNasdrSmdtba�dhassham ReghW Wagesedge mobWma sWk dwpvNNape terrawWo mmpdbm w kopL PreremseverhedtMmrgMgOW dwrtembattery isle armed mrWma upadty Ilkest tkamge loud nunlhYees dmgt wMage Itpple amd amt%eds baary bit. 0AITEAM Sealed w(btaaaladRe mdda-udstsa (BAMI ady) a INANm bbn PllbglWty bammyc Opt sal RO-0dAaa 4 ��*and No DOW tlmu ��),LIP batdy"onl6FNoWdesswWew"of -cipAvow* 24•1hoiN novel ohm a 90•Mkmde dbitamgt. UmKWdeakMdedpmpw dualmataMMgMawhavetlNONpamtlkcredits,disdwgepabd BmewradplsaatlaWsmmalogstWtlR'to-P Mm**-YpOy�altpeaombal°trap m* mm* M pram eamhai d iA 220. 277 a 347.Odw MW vdmp may wry. ACAXDmwtalasbarmy," nNI bdoreACpow°ba*WmdPsemwbmm&-pfrom dapdm)W Sr!If•Dlagnoala: Caltlaady aalNbn AC fnmNUomaMy.Tut wWMi AM meaatetester AOIAT ooteswry) PovMe mead ottivatloml d 30-Kassel dbgnatic as%p for on-ImnanO viwa NmpKlbn. StaMRd OmapmmRm wadtedg will kL%Wd kwmk W haey, cAagarbNara all displays 9Rm AadMng kWksW Ngl't what In ammgmgr made. Sbgk matl•drawtic LED kmdka%r % sNspky two -state SWAWN@MmdRt 1 TgTPMaWAaR"dm* ACbOCtrambtbmRrydsrgYgasdandMasdadwpfoaemasARMnatic isseR amypaspastbragM hamsbya dm"MwAdteamorelornewdmmnawtearmwa mmy)• ABAcp"tSTM(Sf$AtOgAd ma WAgatlmmyodetramndtsmRnNyallamoralhamremeltstest dtpmeatlUYl-[inmlaautmmatedmea, I RgdRowmNs For morebbmmdmseat AadINIrmahsomSM NaTALU11011-WaitoMcd%mmmmstad.MMd-rase, m I, c mm%magWAWaumallsorb nwimNa mds 7/r esarano, poM m of pdsWtbrgKAud l/r bmaatewy leoi4 mmrmW deem toter Nam Gdc-pate fa ax a hstaluo0 RM mmdN%nma. UgM-ULdmp' ta-1 MWda I mWwetWAftkWwhmmdwkhuRWPVS LKeSAtegade),NNRR70DIBCLNOMNOMObmMamhushma),whimut(aWaatDm calm TWO 20Woo 16053 (111f)(4), RaTNk47, Pat 15, Subpart B adOSNA List and bbekd%a mpywith Canada StaMmds Cn1 Nor 141-10. B WArti WO-hodimtwNAtheBAA"mbm mMWbtheUSAadmamatheBuykwkaln)gmvem- mmRpounmo mgaranems tanderFAR DFARSad DOT. Pkwsetefer% - faradditlmalbkmatlm. WARRANTY- Slow bMadwamme t)lThbbdwmymarramypaddedallnocraw$WmwbbMe spetlAnmamAmamaeywam gofarymaMother mpmesarWWOW wnRntlesereOKWMI& Campkkwarranty win bawdatwwtw.acuitrbrafds.coMwmarttwamntvt mmand-andebm NOT®:Addpmkmwaegd Wuam*dmtf wmmvNmwWmandappikalon. MwkmaRkdpi atypld rakes, nRwM se/erlabaamryartditlent at2s'L *diabimoaks%&mpwid nonce. t Small Batty Chagas Cerdkd bk/�th�e-_G Title 20 Appbamma URf emy Dawbae. O❑�-- t M c@n m„y®icnn EMERGENCY NNAN New ly"! EM EPANL 0 2017 2022 Acuity Brands Lighting, Inc. All rights rmerved. Rw. 02/17/22 star Aftew.-. y CstNNNrdal LED � ELM4L 640 Lumens b ELM6L 1100 Lumens LITHIUM IRON PHOSPHATE NIMEL CADMIUM LEI) MOUNTING AA.madam aR W km taalkmawl Links edlawke klawtd. SA6) O O S.9lliSA6) i 13J7 G3.%! 3.7019J1 *dko- 3.7019J91 lmrgdx 133/8(33.95) 13J7 G3S31 Dto:34SM(9.39) Lklpht s 1sn611s.06) yM t"43b(1.4hg) • wagmt ELMK 3 b 11.41B1 591I1SA6) • O WaphtElMKHO3SBNl1S9kgl WkWEIAAKEHOUSb!(1JIg) 1116121aW ELM4L_ELM6L Pg 1 d5 Speclfications EPA: 0.96fe Haight: 17' Disrnarter. 17' Weight 601bs EML17 Munich Pendant Eurotique Family A. 17- — 143.ikni) r�° Ilan{ r r" B Introduction The Munich is a European -styled pendant luminaire suitable for use with a variety of Eurotique decorative arms and poles. Intended for use in pedestrian areas such as retail environments, public parks, city centers and commercial areas or other spaces with decorative requirements and a contemporary theme. •ue+yR��• - EXAMPLE: EML17 ST 63LED 350MA 4K GCF R3120 DDBXD [EMVTj Srr Smooth iSIMA� s,000Nsnmm 3K Spill [rr� Owdewibt R2 Type �MVK_T � Superaurabledarkhroax Ahlged 49LFDS25MA 6,700iumens ® 4000K GM Gbwckarsag ® Type 12D DBLXD Super durable Mad FIT Robed 63LEDISOMA 6,000lmem SK SOOOK R4 Type4 208 DNAXD SupadunblenaturaalumNwm 63l®S2SMA 8,20o1wram RS Types 240 Dii SupedwablewhiU 277 ANM AetlQW blatk 347 ANDR Amgwdadbonb 40 ANDG Amgwdark green AM AMquevedtipem '.L/TNON/A Cede l.Wh is Wry • Conyers, Georgia 30012 • Phone: 1-800-705•SERV (7378) _ L/G//77NG 02013-2021 Acuity m Li y Araghting, Inc. AN right. —read. COMMERCAL OUTDOOR Base Milo Performance Package Data Is ccnvdefKl Keurm w of ft rwaaon data shown In dw highest opw.tin g twp.rmun wailwe. Antique Str•.t tamps nerves the right to rnodlfy.peceadmw without nod.. EML17 One Lbhonla Ws Rw 1t/11 . L/T//ON/A Y • Co nYen• Gaorgla 30D12 • Phone: l•a00.705-SERV (7378) Pag.1 of 4 _ L/GNA7NG o 20112021 Acuity III Lighting, Inc. All ,lihts r«ennd COMMERCIAL OUTDOOR ELM4L-ELM6L Quantum" LED Contemporary Commercial Emergency Light NICKEL CADMIUM BATTERY MODELS li lather%dladthes,moflpurepoductwkmAeMMeattkles ExamplA: ELM4L �`:.`. ;.. -., ,tA�': -s •. � �,n t ii'sk. �'s ti - .. �3,3': . ... L ,r%p.n l.. Y"35 gLAllls 6401smais, OMW SP6401.640 010* White (black) 12D•mVAr_SQAN b (Abdo) NkM WaNk) None Oalw none WMw SkWA4Lp6 B Wank MT 1V-WVAC5Wft WPVS p,Qwmvmrda twos BAA say, Ammica(n)Act CbmpNat Ill pmd mMown' New t OoanatwppamNnmaloa4 2 WntboadaNwMnmkgkrtwtWAON&Wk$tW&WPVSW*OutarWmlpsnwmetyaoWoWwM mahh ha: W1VS LAG 4 haaws ddwxed kmern p a 20%. Sre spa short }ypy) for mar Mklmalkn. 3 P opnmwaMdudeal2•bnp 3A-16UNCtluxdedWand aardwan.NNaraBaMe wNAKy LITHIUM IRON PHOSPHATE BATTERY MODELS (I ladKrintladtNmmmMMnepmoONtashwNWlerxUaaa EnalaDle: EMU UVOLTLTPSDRT EPANL mowmms, RWAW MW640kmen, ON* White VWT 120-347M LiP Uddlembon (AmN none' UN LmmMmphemb, ad)wUbleoptls twtwowm lem Spot Pon, B thick SOl6dk ph0° Stillyd4pnostkt NO Lbph•omPnbatury mnwttw ENO Exba Nth -output RMK 11001uimm, NWAO SMIOOLI1MkMKk AELR Nommated battery WNA"Wdo ttwoWnKp SpdPaerrl REssarah WPVS Warm praatlre w Idah dmWd' SAA 81ryAmerkaWrlict Corrlp ent PM PendenteouM' WPVSLRGW Wet protecuvemuladOWd, white bulstbeused for wet location spouldons) WPVSLAG B Wtt ro dive MdddeKW(mwtbeusxdfawetbcabnaWkaHow ELAWGi Wit pairt131WHx15TWINxrD(wepecsheetELA-WGl. RTKR Ram* test MtbptoWsway (NrNdesgogples, Law and battery) EUA4L-ELA16l mounted ksMe to WPVS Mew 1 fawdadim•raarNaatapamybstaMad.NenflMMand EIMAWaykraaiowsaecapatakwMbahSORfand real-SDAT odorant kw page q. 2 OMyarO"wMUW. 7 SORTpdaopWrN.AfLRraaoaamManmmAR•aMaunuW taw numsanddktpmesdalaamatlw hr+danimd NP•iflp nqukaatems.OdyaradaNewmhliP bbewytypa, MKwamaMawNA EAAaplbu. t RMQwM lUlOa WpAawdaaavdlYlewM50m. ElM6lwM LLNaNyawlaMewM Sat. S Munlies edwhmWgfawetkWmWkmim WPVSkabodandthlpaWWM*NWOWwMm*ch Mc WPVS UMN, hoasaiddNmNkmMsupw2p%. Srespm dmNYyPOlorumrekfamaNw. s PaWau ewmoptlw wakrdWratY lap 3It 161NICtkwOe/Waadkmdwme. NotwWMewith ayaaerk pths IA L/1)'1I0/V/A L/ONf JVO EMERGENCY: One Llthonk Way,(Omen,GA30012 Pfane1-8W705.5ERV(7378) teshsl4gortemageory0acalykandLcan w Jlthbda.can ELM4L_ELM6L D20102022 Acuity Brands Loring, Inc All rights reserved. RK.03/02R2 P%2ofS Select Your options From w 3naekw, m medaw Notate____..___.__ Mutt wIm ST, PIT, or FLT style. Select Your Choke From Mdljrr.HeM IN%f7lIM KrAjtallM IMe)1Mw �_ mew!!DM aNeanlw l aramsfmaa Select Your options From x steat -- a .. } x -- - -- won - __1 EML17 Rw. 11/11/21 Page 2014 IA L/THa mA L/GHT/511 FEATURES & SPECIFICATIONS NM IkTrIA VS1-Mod for Applications requiring low-pgMe,athatNaemergewlghtNgwith 7M mmAy-oNornwnmb-mwNhOWKSm".PmWesimk*nmdgon'meofMmmM&ft ER both Indoors and outdaaspal bmdAC Tower. Cwtab okbom ammhmabcrdiadmbN tMYmopill ofwylkmd*poynmioNob. mddteaurddWpwhhdktartMmbunnhouft AFFINITY® FblblesmetextalKdpowdeaatparforwMwalldarkbmn.TenttwhdallkdmWNgM Ole Cas<AtdltaCtYYaIFah arebod located on done booms dthehasbg Mr unit and rmmoreaM btasNy aotemble all visbk fcarndefloa. tiv&Wn LEL%MmklnEnwpdL70d60000hdunsDeNrenI275NemntbNomWOn AF0 bpKallen and 350keRns b Eflmrgentyaperatbn Wide Nmowdistleutlom0atdoawMetMowdistrbuuomm:3G p' Del' degrem)ata 7.5' momHnq he1pMw1th 1 FCAwmI s,000KcareMtedbobrtmpmstureftCi). � . RKTRICAL-NIVOLT (120 Uuu 27N, 5001U).Onat-NmNbg tAAryemAxMslm b "Bkand sA mWmlusemocawmpum%provMe IowoperaBp cam. Slmal BAtteryourposcer" in use CAT62DA"NameEfflckn *IbM. or, RegubtMcorgerolUgemabndmastaMcchxgevolnpeavaawNkrageaWkrolUges. pp1 d71 PrinwosowsrndenhArgingNutsharrlsbattery life and reWascapacity. FWeredcharsprinput t t" m Wm m torryvoBage dppk &adatendsbattery life. Photoali fwm standard for n rmay on roducttoftwmrtMw aftdwklgWo6wonpmblw4Mitpmem. BATTERY: Staled, makrtma"free nkket-cadmium. p? SEIi•BIAONOSTICSWOPTION}AuaaatkN-hburredageaftaA90-ndnuadhchage. � # �1'. Adranad ekchkal desire providasconstant NgMoatputthrougAart dmeMkedbdarye period. BrownmH protKtbn is w%inaduMy swNdRd % enmrgemy mode when supply voMagedrop below - WpabuMyMpmW non" d120V. AC/LVDre-setallows battery connection base AC power b aWiW and Prermwa bd" &-p lrom dap disdwroe• kitWagma ftQMBwo*MMN-ACPomtbnaBy.Standmdderage—retailer" will kidWk MKwmemd buttery, dwguf*m AM dkp * green Amhbp kWbwBgMwhite b amrpeecymodc Shaille mol-carewrtLED bdkxortd°hpl"tw°'UUdAl%test adwtkm MOUNTING alit' Selldbgnmtkkstlimp30stanOsevery30dAysand90mMuus+mwUy.DMpiwsdcerduAtbna AAdmvd mxekmhes(dhMmdm). Ianps,MwDCtrar6etbaKydur"mal mdltbnofmkropraessa. 44bs(2gq) MAmultmllg TemswMdhprpvMesnanuaactkadmd3o-seand/30-mMnme/90 minutedbgras Clis opum:4bbsu.lhol rut tes" for m-demAM Waal kmpKuoe. !INSTALLATION -Wall mount: typically nual7.5'to If mgmdq height from pound or floor. Pow wpplkdbyOft mounting d"to&4"sguarea4"ocMpnl-boli(wall mmm)and LaegU:61/2(i6,51) 101/2" accptsngteaAaaeduR Date: 3 3/4 (9.53) Iky1d:101/2 (26.6n 314' LLSi1Nif-UlwmloMimlbtedstuWWat32.122"FIO-SM)•UWtwkbCW(cddweadw)Nsted wwa for•22•F%122'F0VtoSM).Mwuoreun&all&WkabkrephmeMforUL924,NFPA101 SyAmdadPsatoayapdm;41pMI1.9Np) WwmtLlkSdMcc&),NFPA70(NECLCdNomkWWCwd"IW nTWe2Cmctbml6o53(WNA, CWtNmyo don:4,41k(2.0kj) FCCTIde 47, Pa 1S, Su*rt BsndOSKA. MtruChy of 0kap Code. WARRANTY - 5-yearlinited warranty (&fiery Is pre -mired). Thus N theonlyweary provided all eb odesbtemmm M Miss spKNlcatbn sheet Dense any warranty dap kbM. M athK expmsast MOW waanum are dhd fumed. Complete warranty term batedat Neu:A%emAyMKaammMommngNAb. Mrnmade* ortypcdwluesmmwWunder Wormy amNuonsat2SC ® (a (a ® x t Speclfiaums wblect to f ding! wMw noft LIM tSealBKRryOhagmsCeubdbdwCARde20AWmceEl &wD"m. SELP•POWEREO MDELS ' Fortbeshr mkadgradwAlopodowbgboMWgusm Exaspir,AFODSIll NSDCW 1 .; i _ j, ..F. L �" .�,W, [WAFFNIITYoval Wi� Whhetexturm [AWOLi] 120-277,50/60k (] NWO ®Sep ieprostlm CW CaMWeaher00.50C) o• Dad6rometextunst EMERGENCY AFT) EMERGENCY LIGHT I� Lmv,ajv/A L/GHT/wo- FEATURES & SPECIFICATIONS tNTa1a au- opal appluaeam Mack tadem,lrkhlos, anhrmoe want all pnvKe elRas. ramMlAaeTMM — 6900 W seed "KR*4VKW Axmk pahaund lad Portion an with aKrom-himped stow awrsaadW"Wkbm.kbtto McNRmedbYWOM pkVL Vwdc* *MiWmwm"katbmwNhommwWbKhenpmpmi e3-Y4•KKladpm"K two rmrabmbn W-IW and kw W aKd arts for ma1pM-throvph coMWt rem capably: 114 in, 4 out), No. 12 AWG tandutwn, raW fa90'C. AcmnaMnm lr•2r Pam Rsamq• PamhetoalnpthmnW manapeamat kr25Y mMad; hlgk analam (40Y) •Pmm awlMble. upM mgNm and drNds all Ktaabk hem aaaw a below tvMrg. MKa1NnglhMnea t•t/r. OtW—LMare turned wa3•tapSDCM;60CMrkrmote.9bCMoptimal. 1ID 1qm sewn tauead wed a/ W ip aptl[d Iem. GaaaN WwmMahm Xpmklp w4tll t95lMNandR•aweAKswnaandaoarotmapa. LN-Mpad KmaW NAectm m IWWO, xerhspealoh Or mm clew Ukku, AM mg" In wane and block pakrel NANKs RKWM — MWWmk (1I0-27TV, SOAmh) 0-IN dkudnp Given moemed to hmmmom bw 10% or t16 mW won dbwdagNwl arawble. G16YdlouakipANwenpWmtwold adahuW Nw•wMapwsmw6rpWkd. To% knrm mwmmnrta x w.Da bar. USI —Cw MN K US and Canadian sally starAwds. VAN location sumawd leaned or", MSS Nord. EIMAGY STAI nOWpNdat. Wit' Aaal AN — deduct with the 1AA "in A KwRaa d IN tore USA and meNs the Buy Anwekdiil l o eram•m prouuemamrwiserm mbwderfAR, OFAASall DDT. Pleaw ra1KwwwwarwtrMared,.csM6ur amerkan foraddM" IaMAMtY—Sryw Nmmkwaranry. ThhhlManbtwrramYPrN'MadaMmathasuwrnsxnlnthbs"cMotlan Omtmawam"n"rfan Mod. AN ohmnpmdineI pled waremlesreaac4MW.cKnpkkremarry worm humel wow.+[ultrbnnds.e.miwnaon/w+rrantr[tamaaM-mndlaam MdakbWlmrkrmara aareNhrKanwhaad-KwaMmrmmntKdpgkanan. AN rakms are d W pl a typical rWas, mwauae uMa bballory taKNbm d 25 Y. Spd6tatbin subPact a charge wMad wtla. r $Not Naas TIP C LDN6 LAM w 6- Opse atoned WaNWash LED NeMC Nor fontrudi" Ost1LNNgM AOLN wain" Fad*m*Ovarydepend!NMCI MWK6N.Q"whhyarsdeSrrANOW, hialispIC UW63S115L06ARLSSMV0LTEZi0 LDNO a. 1 . -. , �, ,`£i fa • S�,i<'. .. _ Z: :�; i. 54WOtt; 6"round 27/ 2700K 05 500wm 25 2SMlumens jo-nw n Clear nSembspecub, MVOLT MWtl-welt 3W 3000K 07 1SOhmem 30 "Millumens LW6 Wallw(ds warWhite l6 Maeom 120 12N BOOK l0 1000Iumam 40 4000Nmem 11111 Blarh LS SpKa° 277 277V 40! 4000K lHoumens 50 Mlanm 347' 347V SOOOIf 20 200ohemm rs•; .)�„ , ) ter F.. r •t a'f';a 7 �, 4st"� ^" r" , 0v- 4- a. _.-f ..+.:,:3� w•r.r-. , .1x �e' .':v� "s..r; ,*.1 J!'�n :.1 T'h...Ti.s, )t' ",+!!'t'!',.r'd .fed, 'a.,.... i, 00 0.1011drkerdbmal0% SF' Sbglehne NM' nLgM'LumenCompmutba 0 0-1011drimrdbms%196 TRW' WMtepakurdAmge or Wbdeum nmwwkh"lmtoneicKh.p*" 010 MbMRmdi=,TO% MR' Warkpabadinge I IBISBNir 4�M4Bmq 1MgEMttpM!pk 111VajF1�9NFMp QO drverfaaewithlOT EL' EmnergemybnteyWdwithime(pdwtswitd.lOWConstant Power, Not *$la �ltw � pact tAgddll�dAw11�A1>tpDi 01 MMbwmdhmmbg1% CM bCAThk MAEDBS an drlrerFauwwdt112(111T ELRe 6neroentyGtterypadwithnmobetest Iwo. I WCoatmmpower,Not MWCpu ChicaglA6haA6lnC0gN0it pill 11AM ' E NMleeddmbybemyl200padwNhseN-dMOnosOctlme� uhHs 1t&I0Vf RRL- RRELDC'oroRAdykanindrecmnertaamabbasN0AMconsistent ComtAKPawrow NdGrdfmdNCATK1emMAEDBS fxtMlmpfkdopWnmomalAKWo* mbr&Ws.Av4NAbkoay /IwA ELRSD' 6lmrgeKppKt wTithwIFMlAplosNcsmllaeastswNd.tOWColatAm inMOA, MU, WKAE,AndWR(12S.All toRLsame shoutonwww. /owetNotCeroRedINCATItk20 AEDSS WA"W".comforthelMp dKt*edRcnWm 10 $WdMBLa4ft Elmo. batKrypAdl,tOWComtAMPowerwNAMmgratKtwvNd. 1 NLTMRP MgM•Air abbd �MU11He20MAEM NLTANNR2s" nLgM'AMDNmmbgPad Windlass Canrds.CamraNRxmresm EIOWCPR' baeypafblOWCamuntPowerwathremoottestimm. mmergtaydroat%tawNaNewMhhatrerypadoptbm kNA NP►160' MC�qqte•dMymmmwmkTNk2AMAE08 NLTAMRsP 9WAMkw4Pad WWMCmh9k.U1926Emerp"Opers- lOAO ekkLEODALI50lDANE N110,GZi). P �bPP wNhOIOVdkamkgfanoneldoLEDOrhkrs 0 ylessiwersetKnlptkwft.AwAftMthotterypadopoons. dim%darkMAlyAmaica(n)A tCo pNwt NPPifA� (MG210 aj �arwioro RxtwesmemKgellcyd fanal•adafDMvers 9" Hk311Cm"+) GZt New _ 1 Dwr4N MlgMvablkxWaMrwnpKkAq:rMerwdhnanfbaWdMt 9 Ndmi"wohcp NPS10E;N/snm NPP16DW OMNNw 2 M aul"wrd%Wft 10WLTTAIIMNL1AlAMMd NLTAMEM2rMmWnmded%nwWaYMp PS1055CP FAIC power $"t%batmrypack, rA complM t 3 xotwawblowtmemryamrpmam• k#auad m, Reed lmulble, 10wconstant power 4 MKtsp o"bpel2wwll7V. 11 Fhmueh lb6rforallhumpacksp swIth A0. S AwNbMewmhdrar DUOtaMctaody. II Wit vd fotJOODkeardabow.5000mwkh mark -spring EACISSM375CmhpKthlUrmptibieemergemyACpow system 6 tIS"dpN umdkp<kdtgAcawnga4dfalNterypadaNmwaw. 24Lx24Wx14H.Not wbkblowkhemarparcybmd Nackcon. FAC ISSM.i25 Compact MtemgMMtomergM AC power" am 7 SpedfywhApe.fRfarKewNhpnabtawppyFM powa.WWngWnaa 13 MmspaNyaOaDl dolor.NabraNaMewbAnlpMaDNdn.NdawN- 6RA6mS oveNakd trim dp with r outshie diameter a =bh%qrA w% tkwI Must akkwM CK NNnew mendadfamNN taMrglosldWlan.Natlauw SCA6 SkpWLMq AdApW.Degw ofdWmwtb@wMW NPSea2ER. %dywaYiblewMEZIOwW I&I"mMmwsroE2a wMemapearybadwppewKmvaadMrthwbxMrypsdm ISD lOD iSD,IOD,25D 30D)AxSCASIW DOWNLIGHTING LDN6 GULF COAST ELECTRICAL DESIGN 2111 Sunnydale Blvd. Suite D Clearwater, FL 33766 (727) 330-4937 1 www.GCElectdca[Design.com Florida Board of Professional Engineers #33905 p U) z� 0MIEW 0 C L V Ld a 10 a F01 - is • � L Ajj Mg u Q am to n Seal Andrew Z. Pavalis State of Florida License *%063 Date: 2.9. 22 Checked by: AZP Drawn: MAH Job: 21-042 Sheet E4*0