HomeMy WebLinkAbout7866 Gall BlvdBUILDING INFORMATION APPLICABLE CODES ALL CONSTRUCTION SPECIFIED ON THESE DOCUMENTS SUBMITTED FOR BUILDING PERMIT SHALL COMPLY WITH ALL CODES AND ORDINANCES OF CITY OF ZEPHYRHILLS, FLORIDA. INCLUDING REVISIONS, AMENDMENTS AND APPENDICES TO THE FOLLOWING CODES: FLORIDA EXISTING BUILDING CODE 7TH EDITION (2020) FLORIDA ACCESSIBLITY CODE 7TH EDITION (2020) FLORIDA MECHANICAL CODE 7TH EDITION (2020) FLORIDA PLUMBING CODE 7TH EDITION (2020) FLORIDA FIRE PREVENTION CODE 7TH EDITION (2020) FLORIDA ENERGY CONSERVATION CODE 7TH EDITION (2020) ADDITIONAL APPLICABLE CODE NFPA 101 LIFE SAFETY CODE FLORIDA EDITION NATIONAL ELECTRIC CODE 2017 EDITION FLORIDA EXISTING BUILDING CODE 7TH EDITION (2020) OCCUPANCY CLASSIFICATION FLORIDA BUILDING CODE, CHAPTER 3: SECTION 304,1: BUSINESS GROUP B CLINIC, OUTPATIENT BUSINESS GROUP B OCCUPANCY INCLUDES, AMONG OTHERS, THE USE OF A BUILDING OR STRUCTURE, OR A PORTION THEREOF, FOR OFFICE, PROFESSIONAL OR SERVICE -TYPE TRANSACTIONS, INCLUDING STORAGE OF RECORDS AND ACCOUNTS. OCCUPANT USE- CLINIC, OUTPATIENT Buildings or portions thereof used to provide medical care on less than a 24-hour basis to persons who are not rendered incapable of self- preservation by the services provided FBC 202. CONSTRUCTION CLASSIFICATION FLORIDA BUILDING CODE, CHAPTER 6: TYPE II-B CONSTRUCTION - EXISTING CONSTRUCTION PERMITTED EXIST SHELL BUILDING INFO BUILDING HEIGHT: 1 STORY SPRINKLERED: NO MEZZANINE: NO FIRE DISTRICT: NO e. INTERIOR FINISHES FLORIDA BUILDING CODE, CHAPTER 8: BUSINESS - GROUP B (NON-SPRINKLERED) INTERIOR WALL AND CEILING FINISHES REQUIREMENTS - TABLE 803.5 EXIT ACCESS CORRIDORS / EXITWAYS: CLASS B ROOMS AND ENCLOSED SPACES: CLASS C BUILDING / UNIT INFORMATION TENANT S F. COMMON AREA S.F. TOTAL FLOOR S.F. 1ST FLOOR = 6,706 S.F. N/A N/A ADDITIONAL PERMITS ANY APPLICABLE PERMITS OR APPROVAL REQUIRED BY ANY OTHER GOVERNMENT AGENCY (DEP, DOT, SWFWMD, COUNTY, ETC.) ARE THE RESPONSABILITY OF THE APPLICANT TO OBTAIN. SCOPE OF WORK INTERIOR FIT -OUT OF NEW 1-STORY SHELL BUILDING (CONSTRUCTED UNDER SEPARATE PERMIT) - 6,706 S.F. Occupancy use is for Clinic, outpatient used to provide medical care on less than a 24-hour basis to persons who are not rendered incapable of self preservation by the services provided per FBC 202. Spaces include exam rooms, waiting areas, physician offices, staff break room, toilets, janitors closet, storage rooms. TENANT REQUIREMENTS EXIT REQUIREMENTS NUMBER AND ARRANGEMENT OF EXITS: REFERENCE DRAWING A0.6 FLOOR MIN NUMBER TRAVEL DISTANCE ARRANGEMENT OF EXITS I MEANS OF EGRESS REQUIRED SHOWN ALLOWABLE SHOWN REQUIRED SHOWN TBL.1021.1 ON PLAN TBL.1016.1 ON PLAN BETWEEN ON PLAN DOORS TENANT 300' 55'-7" CORRIDOR DEAD ENDS (SECTION 1017.3) COMMON PATH OF TRAVEL (SECTION I014.3) OCCUPANT LOAD ANnEIDTH CALCULATED OCUPANT LOAD - EXISTiNG BUSINESS BUILDING = 6,706 SF BREAK ROOM: ASSEMBLY 358 SF / 15 NET=COMMUNITY: 394 SF / 15 NET = 27 PERSONWAITING: 179 SF / 15 NET= 12 PERSONS COMM ROOM: 61 SF / 300 NET = 1 PERSOELEC. ROOM/F. RISER: 101 SF / 300 NET= 1 STORAGE 1: 33 SF / 300 NET= 1 PERSON STORAGE 2: 86 SF / 300 NET = 1 PERSON BIO: 12 SF / 300 NET = 1 PERSON J.C.: 34 SF ( 300 NET = 1 PERSON TOTAL OCCUPANCY = 106 PERSONS PLUMBING FIXTURE REQUIREMENTS OOR MALE FEMALE BUSINESS REQUIRED PROVIDED REQUIRED PROVIDED 106 PE ONS TOILETS 2 4 2 4 LAVATORIES 2 4 2 4 SERVICE SINK 1 1 DRINKING 1 1 FOUNTAIN NOTE: TOILETS EXISTING BUILDING PROVIDED NOT IN SCOPE OF WORK FIXTURES REQUIRED / (FIXTURES PROVIDED) LEGAL DESCRIPTION PARCEL ID#: 35-25-21-0130-00000-0040 ZEPHYR COMMONS PHASE 1 PB 65 PG 132 LOT 4 OR 9254 PG 1646 SITE LOCATION ARCHITECTURE / INTERIOR DESIGNER CAMPBELL + VAN DUSEN DESIGN STUDIO 255 SOUTH ORANGE AVENUE SUITE 1240 ORLANDO, FLORIDA 32801 407.930.6016 CONTACT: FRANK W. CAMPBELL CONTACT: GLORIA VAN DUSEN ELECTRICAL ENGINEER PENINSULA ENGINEERING, INC. 2016 ALDEN ROAD ORLANDO, FLORIDA 32803 407.246.1688 CONTACT: BRYAN SPANGLER ADVENT HEALTH WELL 65+ ZEPHYRHILLS MECH & PLUMB ENGINEER PENINSULA ENGINEERING, INC. 2016 ALDEN ROAD ORLANDO, FLORIDA 32803 407.246.1688 CONTACT: BRYAN SPANGLER 7866 GALL BOULEVARD, ZEPHYRHILLS, FLORIDA 33541 BUILDING OWNERS CONTRACTOR ADVENTHEALTH TBD 900 HOPE WAY ALTAMONTE SPRINGS, FLORIDA 32714 407.963.1014 CONTACT: DANIEL TOM E1 , v iv, , `� l 1&f l }� 16 CAMPBELL + VAN DUSEN Design Studio, LLC. 255 South Orange Avenue Suite # 1240 Orlando, Florida 32801 Phone: 407.930.6016 FL. Lic. No, AR0016053 ARCHITECT OF RECORD FRANK W. CAMPBELL AIA FL LIC NO. AR0016053 COPY OF THIS PLAN IS NOT VALID UNLESS SIGNED, SEALED AND DATED BY THE ARCHITECT OF RECORD COPY OF THIS PLAN IS NOT VALID UNLESS SIGNED, SEALED AND DATED BY THE ENGINEER OF RECORD �I LU .J Lr) z LL! _ LL Q � LJ__f N J H J rill LU N n r J� IW Q 00 (") i� ('7 CONSTRUCTION DOCUMENTS 03.24.2023 PRINCIPAL IN CHARGE F. CAMPBELL PROJECT MANAGER M. TORRES ADVENT HEALTH WELL 65+ ZEPHYRHILLS 22-0328-01 COVER SHEET ELEC. ROOM/ FIRE RISER = 101 S.F. @300=1P PROPOSED BUSINESS OCCUPANCY TOTAL TENANT AREA SF = 6,706 SF BUSINESS AREA: 106 PERSONS 5,448 SF@ 150 GROSS = 37P BREAK: 358 SFA @ 15 NET A 24P COIWMU NITY: 374 SF-@ 15-NET= 27P WAITING: 179 SF @ 15 NET= 12P COMM ROOM: 61 SF @ 300 NET= 1 I ELEC. ROOM/F. RISER: 101 SF @ 300 NET= 1 P STORAGE 1: 33 SF @ 300 NET= 1 P STORAGE 2: 86 SF @ 300 NET= 1 P B I O: 12 SF @ 300 NET= 1 P J. C .: 34 SF @ 300 NET= 1 P TOTAL OCCUPANCY= 1,06P OVERALL DIAGONAL= 1 19'-8" DISTANCE BETWEEN EXITS= 74'-6" MAX TRAVEL DISTANCE= 55'-9" LIFE SAFETY LEGEND ALL DIMENSIONS ARE ON CENTER FROM FINISHED INTERIOR SYMBOL DESCRIPTION DIRECTION OF TRAVEL TRAVEL PATH DISTANCE BETWEEN EXITS DIAGONAL DISTANCE e LIGHTED EXIT SIGN: TWO SIDED, FROM DUAL I l DIRECTION, W/ BATTERY BACKUP. CoLIGHTED EXIT SIGN: SINGLE SIDED, FROM SINGLE CQ DIRECTION, W/ BATTERY BACKUP. ® LIGHTED EXIT SIGN & DUAL EXIT LIGHTING COMBO: SINGLE AND OR DUAL DIRECTION .-- W/BATTERY BACKUP. FECR 'E? NEW WALL RECESSED FIRE EXTINGUISHER �I KEYNOTE SYMBOL * FOR SYMBOLS AND REQUIREMENTS SEE ELECTRICAL SHEETS. GENERAL NOTES THE MINIMUM FLAME SPREAD CLASSIFICATION OF INTERIOR FINISHES SHALL BE: FOR EXITS AND EXIT ACCESS CLASS B FOR ALL OTHER AREAS CLASS C KEYED NOTES PROVIDE RECESSED FIRE EXTINGUISHER CABINET. l0A B.O.D. LARSENS (OCCULT SERIES WITH BLACK LETTERING) FINISH SHALL #4 304 STAINLESS STEEL. LOCATE FIRE EXTINGUISHER CABINETS IN ACCORDANCE W/LOCAL CODES & PROVIDE ARCHITECT W/ DRAWING OF LOCATIONS FOR REVIEW/APPROVAL PRIOR TO FRAMING OF WALLS. AVOID LOCATING IN FIRE RATED PARTITION (PROVIDE SECOND LAYER OF 5/8" TYPE "X" G.W.B. AT BACK SIDE OF CABINET IF LOCATING IN A FIRE RATED PARTITION). CONFIRM FINAL LOCATION AND QUANTITIES OF DEVICES WITH LOCAL FIRE OFFICIAL. CAMPBELL VAN DUSEN ARCHITECTUREINTERIOR D SI` I CAMPBELL + VAN DUSEN Design Studio, LLC. 255 South Orange Avenue Suite #1240 Orlando, Florida 32301 Phone: 407.930.6016 FL, Lic, No. AR0016053 COPY OF THIS PLAN IS NOT VALID UNLESS SIGNED, SEALED AND DATED BY THE ENGINEER OF RECORD Lj- ry W F=- IV J > w w _ � m _ + — U Z O af Q O 0 w cl— LL <C S LU N 00 c") 1 � CONSTRUCTION DOCUMENTS 03.24.2023 NO. DATE I DESCRIPTION 1 08/04/2023 IREVISION 1 2 108/25/2023 IREVISION 2 PRINCIPAL IN CHARGE F. CAMPBELL --------------- .O M. TORRES f I 011"i a Joe r ADVENT HEALTH WELL 65+ ZEPHYRHILLS 22-0328-01 LIFE SAFETY PLAN LIFE SAFETY PLAN 1 /4" = 1 I-0" —7-t i—TIT-, 1Tc --i--1 -- A0.6 5/8 GYP BOARD SOUND BATT INSULATIO WATER HEATER - SEE MEP FLOOR PLAN SYMBOLS ° DRAWINGS FOR REQUIREMENTS. ® ROOM NUMBER SECTION 3 5/8" 25 GA MTL — STUDS @16" O.C. NEW WALL FURRING OVE INTERIOR OF EXISTING CMU WALL SYSTEMS 5/8 GYP BOARD SOUND BATT INSULATION 3 5/8" 25 GA MTL STUDS @16" O.C. METAL CORNER BEAD LOW WALL SUPPORT BRACKET 1 /8" STEEL METAL STUDS @ 16" O.C. 0 ® 3/4" PLYWOOD SHELF 2"x4" P.T. WD FRAMEING O WINDOW TYPE* DETAIL HE)DOOR SYMBOL- SEE DOOR SCHEDULE * �•� DOOR CONTACT _ FINISHED CLEARANCE C.R. CARD READER MINIMUM DIMENSION MAY BE METAL CORNER ®� = C.o. CASED OPENING* VERIFY DIMENSION COMBINED BEAD I ° ° N WALL TYPE - SEE WALL LEGEND & SHEET AO.5 R i -� RADIUS OF CLEARANCE _ AL _ _ ALIGNMENT LINE ITEM ABOVE OR FURNITURE/EQUIPMENT N.I.0 CENTERLINE o x METAL CORNER BEA ° BOTTOM CHANNEL e 2"x4" P.T. WD BRACE ITEM BELOW — — POB POINT OF BEGINNING FOR LAYOUT INTERIOR &CABINET ELEVATIONS *NOTE: SEE SHEET A2.3 FOR DOOR & WINDOW TYPES ® WALL EXISTING EXTERIOR WALL SYSTEMS EXISTING STOREFRONT SYSTEMS CONNECT WALL BRACKET 0 SUPPORT TO FLOOR, AT EACH END OF WALL, W/ (2) �7f2r� 1 /4" EXPANSION BOLT NOTE: SHELF MOUNTING HT. SHALL BE DETERMINED ON SITE. BASED ON REQUIRED SPACE FOR EQUIPMENT BELOW EXISTING EXTERIOR WINDOW EXISTING WINDOW MULLION D-1 FRAMING DETAIL - AT EXT. WINDOW JAMB D-2 FRAMING DETAIL - AT EXT. WINDOW D-3 LOW WALL SUPPORT BRACKET p-4 WATER HEATER SHELF DETAIL *NOTE: SEE SHEET A2.3 FOR DOOR & WINDOW TYPES AZ.O sc ALE: N.T.s. AZMULL. sc�LE: u.r_s. SCALE: N.I.S.N..s. AZ.O TYPICAL AT ENDS OF LOW WALLSZ.O PROVIDER WORK ROOM 132 119 SF 1 CONSTRUCTION PLAN A2.0 1 /4" = 1'-0" PLAN NOTES: (BOXED NOTE NUMBERS ARE KEYED TO PLAN) IT IS THE CONTRACTOR'S RESPONSIBILITY TO CHECK WITH THE BUILDING OWNER WITH REFERENCE TO ROOF WARRANTIES AND/OR THE PRESCRIBED REQUIREMENTS FOR NEW ROOF PENETRATIONS. IN NO CASE SHOULD CONTRACTOR DO ANYTHING TO VOID ROOF WARRANTIES. CONTRACTOR IS REQUIRED TO HAVE BUILDING OWNER'S ROOFING CONTRACTOR MAKE, SUPERVISE, OR APPROVE ALL NEW ROOF PENETRATION. lA THE GENERAL CONTRACTOR AND ALL SUBCONTRACTORS SHALL MAKE REDLINE AS -BUILT NOTES ON THE DRAWINGS OF ALL DEVIATIONS FROM THE PLANS MADE DURING THE COURSE OF CONSTRUCTION. CONTRACTOR SHALL SUBMIT REDLINE NOTES AND DRAWINGS TO THE ARCHITECT AT THE COMPLETION OF CONSTRUCTION. IF NO DEVIATIONS OR CHANGES HAVE BEEN MADE DURING CONSTRUCTION, THE CONTRACTOR SHALL SUBMIT A LETTER TO THE ARCHITECT STATING THAT NO CHANGES WERE MADE. 1 B SUBCONTRACTORS SHALL GIVE TO CONTRACTOR PRODUCT LITERATURE FOR INSTALLED EQUIPMENT AND PRODUCTS THAT REQUIRE MAINTENANCE OF ANY TYPE (INCLUDING RELAMP OF LIGHT FIXTURES) AND ANY MAINTENANCE INSTRUCTIONS OR WARRANTIES AND THE CONTRACTOR SHALL OBTAIN PHONE NUMBERS AND ADDRESSES OF CONTACTS FOR REPAIR/MAINTENANCE AND BIND ALL OF THIS INFORMATION IN AN 8 1 /2 X i 1 NOTEBOOK. THIS MANUAL SHALL ALSO INCLUDE A COMPLETE LISTING OF IDENTIFICATION FOR ALL FINISH MATERIALS INCLUDING CEILING TILE, FLOOR TILE AND CARPET, AND PLASTIC LAMINATE AND PAINT. CONTRACTOR SHALL DELIVER THIS PROJECT MAINTENANCE MANUAL TO OWNER AT COMPLETION OF PROJECT. I THIS IS EQUIPMENT OR FURNITURE, NOT CONSTRUCTION. SEE EQUIPMENT/MEP DRAWINGS FOR PREPARATION AND COORDINATION REQUIRED BY CONTRACTOR. ALL SUBCONTRACTORS SHALL CONTACT AND COORDINATE WITH EQUIPMENT SUPPLIER FOR LAYOUT TEMPLATES AND VERIFICATION/REVIEW OF ROUGH -INS. 5K GRAB BARS @ HANDICAP TOILETS: 1 1 /2" DIA., 1 1 /2" CLEAR FROM WALL. 33"-36" ABOVE FINISHED FLOOR ANCHORED TO SUPPORT 250 LBS. ONE 42" LONG AT SIDE OF TOILET. ONE 36" LONG BEHIND TOILET. (SEE TOILET ROOM DETAILS FOR PLACEMENT.) 6A INFILL EXISTING WINDOW OPENING WITH 3 5/8" 25 GA METAL STUDS 24" O.C. W/ 5/8" DRYWALL FINISH. 6C SEE DRAWING Al.1 SLAB PLAN FOR NEW WALK EXTENSIONS. 6D CHASE WALLS: SEE PARTITION TYPES FOR WALL CONSTRUCTION. 6F PROVIDE 3 1 /2" WIDE 12 GA. MTL BLOCKING STRIPS @ MOUNTING LOCATIONS OF ALL RAILINGS, CURTAIN TRACKS, AND OTHER BUILT-IN OR SURFACE -MOUNTED ACCESSORIES. AT CABINETS, PROVIDE 1 X6 FIRE -RETARDANT -TREATED WOOD BACKING. VERIFY SIZE AND LOCATION OF THIS BLOCKING WITH PRODUCT/EQUIPMENT/CABINET INSTALLATION RECOMMENDATIONS OR NEEDS. 6K ALL WOOD FRAMING SHALL BE KILN -DRIED AND HAVE A MINIMUM FIBER STRESS OF 1200 PSI. 6Q CEILING: SEE SECTIONS AND DETAILS ON REFLECTED CEILING PLAN. DIMENSIONS AND ELEVATIONS SHOWN ON THESE SHEETS ARE FINISHED. ALL CEILING FRAMING TO BE @ 24" O.C. W/GYPSUM BOARD FINISH. 6R ALL WOOD IN CONTACT WITH CONCRETE OR MASONRY SHALL BE PRESSURE -TREATED OR HAVE AN APPROVED SEPARATING MATERIAL. 6V THE INTENT OF DESIGN IS TO ALIGN NEW WALLS WITH FRAMING AND FINISH OF EXISTING WALLS 6X PROVIDE 5/8" THICK, 24" X 24" FIRE RETARDANT TREATED PLYWOOD BEHIND GYP. BOARD FOR WALL HUNG TVs. CENTER TVs ON PLYWOOD. 7A SEALANT: APPLY SEALANT AT JOINING OF ALL DISSIMILAR MATERIALS EXPOSED TO WEATHER AND AT GAPS EXPOSED TO VIEW. 7B SEALANT: PROVIDE A FULL BED OF SEALANT AT WINDOW AND DOOR FRAMES (INCLUDING THRESHOLD) AND A CONTINUOUS BEAD AT PERIMETER OF EXTERIOR AND INTERIOR WINDOWS AND DOORS. 7H SOUND BATT INSULATION IN INTERIOR WALLS AS INDICATED. SEE WALL LEGEND, THIS SHEET, AND WALL TYPES, SHEET AO.4 AND AO.5 8A ALL GLASS IN DOORS OR SIDELIGHTS SHALL BE TEMPERED AND SHALL COMPLY WITH THE FLORIDA BUILDING CODE 2017, SECTION 2406, SAFETY GLAZING. GLASS IN RATED DOORS SHALL COMPLY W/RATING OF DOOR. 8B ALL DOOR HARDWARE SHALL MEET CURRENT ADA AND FLORIDA ACCESSIBILITY CODES. 8C ALL WINDOW AND DOOR FRAMES SHALL BE SECURED TO SURROUNDING WALL PER MANUFACTURER RECOMMENDATION FOR WIND ZONE. 8D EXISTING DOOR TO REMAIN. DOOR TO BE LOCKED & HARDWARE TO BE REMOVED AND OPENINGS CAPPED. CONTINUOUSLY SEAL DOOR USING BASF MASTERSEAL NP 100, INSTALL PER MFG. RECOMMENDATIONS. COLOR TO MATCH DOOR AS CLOSE AS POSSIBLE. 8F EXIST ROOF LADDER AND ACCESS HATCH. 9B 1 /2" GYP BOARD MAY BE USED ON SIDES AND BOTTOM OF DROPPED SOFFITS UNLESS NOTED OTHERWISE. 9C AT ALL CHANGES IN FLOOR MATERIAL, PROVIDE APPROPRIATE ADA-COMPLIANT TRANSITION STRIP. IF AT DOOR, LOCATE DIRECTLY UNDER DOOR. 9E WHEN NOT INDICATED ON PLANS, VERIFY COLOR AND PATTERN SELECTIONS WITH OWNER. 9K FILL IN DRYWALL AT DEMOLISHED WALL LOCATIONS. TAPE AND FINISH NEW DRYWALL TO BE FLUSH WITH ADJACENT REMAINING WALL. 9Y LEAVE 1/2" GAP BETWEEN FINISH FLOOR AND BOTTOM EDGE OF GYPSUM BOARD. 9Z PREPARE ALL WALLS FOR PAINT, TO A GA 216 LEVEL 4 DRYWALL FINISH. 9N ALL TOILETS: USE 5/8" MOISTURE RESISTANT GYPSUM BOARD ON BATHROOM SIDE OF ALL WALLS BEHIND A TOILET AND/OR LAVATORY. 9Q ALL NEW CARPET & WALLPAPER SHALL BE ANTIMICROBIAL TREATED FROM THE FACTORY. IOA PROVIDE AND INSTALL TYPE 2A10 BC FIRE EXTINGUISHER (S) WHERE SHOWN ON PLAN. THE TOP OF FIRE EXTINGUISHER SHALL NOT BE MORE THAN 5 FT. ABOVE THE FLOOR (3 1 /2 FT. IF FIRE EXTINGUISHER'S GROSS WEIGHT IS MORE THAN 40 LBS) AND BOTTOM NOT LESS THAN 4 INCHES ABOVE THE FLOOR. 1 OB RAISED/BRAILLED CHARACTERS & PRACTICAL SYMBOL SIGNS LETTERS AND NUMERALS SHALL BE RAISED 1 /32 IN, UPPER CASE, SANS SERIF OR SIMPLE SERIF TYPE, AND SHALL BE ACCOMPLISHED WITH GRADE 2 BRAILLE. RAISED CHARACTERS SHALL BE AT LEAST 5/8 IN (16 MM) HIGH, BUT NO HIGHER THAN 2 IN (50 MM). PICTOGRAMS SHALL BE ACCOMPLISHED BY THE EQUIVALENT VERBAL DESCRIPTION PLACED DIRECTLY BELOW THE PICTOGRAM. THE BORDER DIMENSION OF THE PICTOGRAM SHALL BE 6 IN (152 MM) MINIMUM IN HEIGHT. MOUNTING LOCATIONS AND HEIGHT SIGNS SHALL BE INSTALLED ON THE WALL ADJACENT TO THE LATCH SIDE OF THE TOILET RM DOORS. MOUNTING HEIGHT SHALL BE 60 IN. (1525 MM) ABOVE FINISH FLOOR TO THE CENTERLINE OF THE SIGN. (IF LATCHSIDE UNAVAILABLE USE NEAREST ADJACENT WALL FOR SIGN). OWNER TO PROVIDE. IOC CONTRACTOR TO INSTALL OWNER PROVIDED AED SEMI -RECESSED CABINET 11 A CABINETS AND CASE WORK: SEE ALL DRAWINGS FOR CABINET SIZES, FINISHES, HARDWARE AND MATERIALS SPECIFICATIONS. THE CONTRACTOR SHALL SUBMIT SHOP DRAWINGS FOR APPROVAL PRIOR TO FABRICATION. 1 1 B CABINETS AND CASE WORK PROVIDED BY OWNER, CONTRACTOR TO COORDINATE INSTALLATION W/ OWNER. IIC AT ALL WALLS RECEIVING CABINETS AND CASE WORK, PROVIDE 4'x8'xl /2" FIRE RESISTANT PLYWOOD BACKING ON ALL 4 WALLS. AS REQUIRED. 1 1 D TELCOM CLOSET: PROVIDE AND MOUNT (1) SHEET OF 4' X 8' X 1 /2" FIRE -RETARDANT TREATED BC PLYWOOD WITH TOP AT 8'-0" AFF. AT ALL WALLS. 12A N/A, 12B PROVIDE CAP SHEET FILM TO GLAZING (SOLYX SXWF-WB WHITE BLACK OPAQUE) AT ALL SPANDREL CONDITIONS WHERE INTERIOR WALLS COVER EXTERIOR STOREFRONTS. 15A CONTRACTOR TO INSTALL OWNER PROVIDED SOAP DISPENSERS AT EACH SINK AND LAVATORY. 15B CONTRACTOR TO INSTALL OWNER PROVIDED DIAGNOSTIC BOARDS IN ALL WELLNESS SUITES. CONTRACTOR TO INSTALL DIAGNOSTIC WALL BOARD BRACKET. SEE DET 2/AO.5 FOR DIAGNOSTIC BOARD NICHE. 15C CONTRACTOR TO INSTALL OWNER PROVIDED SHARP CONTAINERS IN ALL WELLNESS SUITES, LAB AND MED ROOM 15D CONTRACTOR TO INSTALL OWNER PROVIDED PAPER TOWEL DISPENSERS AT BREAK ROOM AND COMMUNITY ROOM 15E CONTRACTOR TO INSTALL OWNER PROVIDED REFRIGERATOR LINES FOR ICE MAKERS IN BREAK ROOM 15F CLOSE AND LOCK EXISTING EXTERIOR DOOR. REMOVE LEVER HARDWARE AND CAP. CAULK WITH EXTERIOR RATED BUTYL CAULK. PROVIDE CONTNNIOUS BEAD ALL SIDES AND THRESHOLD INTERIOR AND EXTERIOR. 15G PROVIDE RECESSED SPECIMEN PASS -THROUGH CABINET - BOBRICK B-505 CAMPBELL + ARCHITECTURE INTERIOR DESIGN www.CVDstudio.com CAMPBELL + VAN DUSEN Design Studio, LLC, 255 South Orange Avenue Suite # 1240 Orlando, Florida 32801 Phone: 407.930.6016 FL. LEC. No. AR0016053 COPY OF THIS PLAN IS NOT VALID UNLESS SIGNED, SEALED AND DATED BY THE ENGINEER OF RECORD J J J rV a-- n = W F_ IV J J LI_1 W m + J Zo Q UJ LZLJ�— i Q LLj Cl— O �00 co PRINCIPAL IN CHARGE F. CAMPBELL ........................... PROJECT MANAGER M. TORRES ......................................... I.......................... ADVENT HEALTH WELL 65+ ZEPHYRHILLS 22-0328-01 CONSTRUCTION PLAN A290 Fgq-&Ejlmll M-10-FN "ma.1, SEMI NOTE: ALL PLAN DIMENSIONS ARE TO FACE OF G.W.B. AS FLOOR PLAN SYMBOLS SHOWN BELOW, UNLESS SPECIFICALLY NOTED OTHERWISE. ® ROOM NUMBER SECTION aO WINDOW TYPE* HIDDOOR SYMBOL- SEE DOOR SCHEDULE * 5/8" GYP WALL BOARD 6 X 6 WELDED WIRE MESH IF MORE THAN 24" WiDE EXISTING SLAB DETAIL D•C DOOR CONTACTS FINISHED CLEARANCE {2j 3-5/8" METAL STUDS TIGHT TO ADJACENT WALL OR CORNER CHANNEL ANCHOR HOLLOW METAL FRAME TO STUD DOOR OPENING TO BEGIN A MAXIMUM OF 4 1 /2" FROM ADJACENT 4 1 /2" MAX STUD LINE 417 DIMENSIONS ARE TO FACE OF G.W.B. U.N.O. GYP WALL BOARD METAL RUNNERS TOP & BOTT 3 5/8" MTL STUDS U.N.O. 4" CONCRETE INFILL a VAPOR BARRIER a 61 APPLY NEW TERMITE TREATMENT 7"a Q AT ALL AREAS THAT ZZACTUAL — SOIL IS DISTURBED. _ T=f I i I=1 f I=1 h(I I I I I —III= TO INSURE STABILITY AT SLAB CONNECTION COMPACTED SOIL C.R. CARD READERS MINIMUM DIMENSION MAY BE C.O. CASED OPENING*— VERIFY DIMENSION COMBINED / WALL TYPE - SEE WALL LEGEND & SHEET AO.5 —L =R—.� RADIUS OF CLEARANCE AL ALIGNMENT LINE ITEM ABOVE OR FURNITURE/EQUIPMENT N.I.0 ITEM BELOW — — — CENTERLINE POB POINT OF BEGINNING FOR LAYOUT — - INTERIOR &CABINET ELEVATIONS *NOTE: SEE SHEET A2.3 FOR DOOR & WINDOW TYPES (1) SIMPSON STRONG -TIE TITEN HD 4' X 4" (MIN.) @ 16" O.C. 2" INTO EXISTING SLAB AND EXTEND 2" INTO NEW D-1 DOOR FRAMING DETAIL - TYPICAL D-2 LAYOUT DIMENSION DETAIL(_D-3__ SLAB INFILL DETAIL *NOTE: SEE SHEET A2.3 FOR DOOR &WINDOW TYPES A2.1 HINGE SIDS_ c DOORS s�owN SCALE N.T.s. A2.1 HCR zoNTa� SEC T�GN sc�LE. N-T.s � � Sc 3., _ 1'-0° IN CORNER OF ROOM C - ---(:D) 1 DIMENSION PLAN A2.1 1 /4" = 11-011 PLAN NOTES: (BOXED NOTE NUMBERS ARE KEYED TO PLAN) IT IS THE CONTRACTOR'S RESPONSIBILITY TO CHECK WITH THE BUILDING OWNER WITH REFERENCE TO ROOF WARRANTIES AND/OR THE PRESCRIBED REQUIREMENTS FOR NEW ROOF PENETRATIONS. IN NO CASE SHOULD CONTRACTOR DO ANYTHING TO VOID ROOF WARRANTIES. CONTRACTOR IS REQUIRED TO HAVE BUILDING OWNER'S ROOFING CONTRACTOR MAKE, SUPERVISE, OR APPROVE ALL NEW ROOF PENETRATION. 1 A THE GENERAL CONTRACTOR AND ALL SUBCONTRACTORS SHALL MAKE REDLINE AS -BUILT NOTES ON THE DRAWINGS OF ALL DEVIATIONS FROM THE PLANS MADE DURING THE COURSE OF CONSTRUCTION. CONTRACTOR SHALL SUBMIT REDLINE NOTES AND DRAWINGS TO THE ARCHITECT AT THE COMPLETION OF CONSTRUCTION. IF NO DEVIATIONS OR CHANGES HAVE BEEN MADE DURING CONSTRUCTION, THE CONTRACTOR SHALL SUBMIT A LETTER TO THE ARCHITECT STATING THAT NO CHANGES WERE MADE. 1 B SUBCONTRACTORS SHALL GIVE TO CONTRACTOR PRODUCT LITERATURE FOR INSTALLED EQUIPMENT AND PRODUCTS THAT REQUIRE MAINTENANCE OF ANY TYPE (INCLUDING RELAMP OF LIGHT FIXTURES) AND ANY MAINTENANCE INSTRUCTIONS OR WARRANTIES AND THE CONTRACTOR SHALL OBTAIN PHONE NUMBERS AND ADDRESSES OF CONTACTS FOR REPAIR/MAINTENANCE AND BIND ALL OF THIS INFORMATION IN AN 8 1 /2 X I 1 NOTEBOOK. THIS MANUAL SHALL ALSO INCLUDE A COMPLETE LISTING OF IDENTIFICATION FOR ALL FINISH MATERIALS INCLUDING CEILING TILE, FLOOR TILE AND CARPET, AND PLASTIC LAMINATE AND PAINT. CONTRACTOR SHALL DELIVER THIS PROJECT MAINTENANCE MANUAL TO OWNER AT COMPLETION OF PROJECT. l C THIS IS EQUIPMENT OR FURNITURE, NOT CONSTRUCTION. SEE EQUIPMENT/MEP DRAWINGS FOR PREPARATION AND COORDINATION REQUIRED BY CONTRACTOR. ALL SUBCONTRACTORS SHALL CONTACT AND COORDINATE WITH EQUIPMENT SUPPLIER FOR LAYOUT TEMPLATES AND VERIFICATION/REVIEW OF ROUGH -INS. 5K GRAB BARS @ HANDICAP TOILETS: 1 1 /2" DIA., 1 1 /2" CLEAR FROM WALL. 33"-36" ABOVE FINISHED FLOOR ANCHORED TO SUPPORT 250 LBS. ONE 42" LONG AT SIDE OF TOILET. ONE 36" LONG BEHIND TOILET. (SEE TOILET ROOM DETAILS FOR PLACEMENT.) 6A INFILL EXISTING WINDOW OPENING WITH 3 5/8" 25 GA METAL STUDS 24" O.C. W/ 5/8" DRYWALL FINISH. 6C SEE DRAWING A1.1 SLAB PLAN FOR NEW WALK EXTENSIONS. 6D CHASE WALLS: SEE PARTITION TYPES FOR WALL CONSTRUCTION. 6F PROVIDE 3 1 /2" WIDE 12 GA. MTL BLOCKING STRIPS @ MOUNTING LOCATIONS OF ALL RAILINGS, CURTAIN TRACKS, AND OTHER BUILT-IN OR SURFACE -MOUNTED ACCESSORIES. AT CABINETS, PROVIDE 1X6 FIRE -RETARDANT -TREATED WOOD BACKING. VERIFY SIZE AND LOCATION OF THIS BLOCKING WITH PRODUCT/EQUIPMENT/CABINET INSTALLATION RECOMMENDATIONS OR NEEDS. 6K ALL WOOD FRAMING SHALL BE KILN -DRIED AND HAVE A MINIMUM FIBER STRESS OF 1200 PSI. 6Q CEILING: SEE SECTIONS AND DETAILS ON REFLECTED CEILING PLAN. DIMENSIONS AND ELEVATIONS SHOWN ON THESE SHEETS ARE FINISHED. ALL CEILING FRAMING TO BE @ 24" O.C. W/GYPSUM BOARD FINISH. 6R ALL WOOD IN CONTACT WITH CONCRETE OR MASONRY SHALL BE PRESSURE -TREATED OR HAVE AN APPROVED SEPARATING MATERIAL. 6V THE INTENT OF DESIGN 1S TO ALIGN NEW WALLS WITH FRAMING AND FINISH OF EXISTING WALLS 6X PROVIDE 5/8" THICK, 24" X 24" FIRE RETARDANT TREATED PLYWOOD BEHIND GYP. BOARD FOR WALL HUNG TVs. CENTER TVs ON PLYWOOD. 7A SEALANT: APPLY SEALANT AT JOINING OF ALL DISSIMILAR MATERIALS EXPOSED TO WEATHER AND AT GAPS EXPOSED TO VIEW. 7B SEALANT: PROVIDE A FULL BED OF SEALANT AT WINDOW AND DOOR FRAMES (INCLUDING THRESHOLD) AND A CONTINUOUS BEAD AT PERIMETER OF EXTERIOR AND INTERIOR WINDOWS AND DOORS. 7H SOUND BATT INSULATION IN INTERIOR WALLS AS INDICATED. SEE WALL LEGEND, THIS SHEET, AND WALL TYPES, SHEET AO.4 AND AO.5 8A ALL GLASS IN DOORS OR SIDELIGHTS SHALL BE TEMPERED AND SHALL COMPLY WITH THE FLORIDA BUILDING CODE 2017, SECTION 2406, SAFETY GLAZING. GLASS IN RATED DOORS SHALL COMPLY W/RATING OF DOOR. 8B ALL DOOR HARDWARE SHALL MEET CURRENT ADA AND FLORIDA ACCESSIBILITY CODES. 8C ALL WINDOW AND DOOR FRAMES SHALL BE SECURED TO SURROUNDING WALL PER MANUFACTURER RECOMMENDATION FOR WIND ZONE. 8D EXISTING DOOR TO REMAIN. DOOR TO BE LOCKED & HARDWARE TO BE REMOVED AND OPENINGS CAPPED. CONTINUOUSLY SEAL DOOR USING BASF MASTERSEAL NP 100, INSTALL PER MFG. RECOMMENDATIONS. COLOR TO MATCH DOOR AS CLOSE AS POSSIBLE. 8F EXIST ROOF LADDER AND ACCESS HATCH. 913 1 /2" GYP BOARD MAY BE USED ON SIDES AND BOTTOM OF DROPPED SOFFITS UNLESS NOTED OTHERWISE. 9C AT ALL CHANGES IN FLOOR MATERIAL, PROVIDE APPROPRIATE ADA-COMPLIANT TRANSITION STRIP. IF AT DOOR, LOCATE DIRECTLY UNDER DOOR. 9E WHEN NOT INDICATED ON PLANS, VERIFY COLOR AND PATTERN SELECTIONS WITH OWNER. 9K FILL IN DRYWALL AT DEMOLISHED WALL LOCATIONS. TAPE AND FINISH NEW DRYWALL TO BE FLUSH WITH ADJACENT REMAINING WALL. 9Y LEAVE 1 /2" GAP BETWEEN FINISH FLOOR AND BOTTOM EDGE OF GYPSUM BOARD. 9Z PREPARE ALL WALLS FOR PAINT, TO A GA 216 LEVEL 4 DRYWALL FINISH. 9N ALL TOILETS: USE 5/8" MOISTURE RESISTANT GYPSUM BOARD ON BATHROOM SIDE OF ALL WALLS BEHIND A TOILET AND/OR LAVATORY. 9Q ALL NEW CARPET & WALLPAPER SHALL BE ANTIMICROBIAL TREATED FROM THE FACTORY. ICA PROVIDE AND INSTALL TYPE 2A10 BC FIRE EXTINGUISHER (S) WHERE SHOWN ON PLAN. THE TOP OF FIRE EXTINGUISHER SHALL NOT BE MORE THAN 5 FT. ABOVE THE FLOOR (3 1 /2 FT. IF FIRE EXTINGUISHER'S GROSS WEIGHT IS MORE THAN 40 LBS) AND BOTTOM NOT LESS THAN 4 INCHES ABOVE THE FLOOR. IOB RAISED/BRAILLED CHARACTERS & PRACTICAL SYMBOL SIGNS LETTERS AND NUMERALS SHALL BE RAISED 1/32 IN, UPPER CASE, SANS SERIF OR SIMPLE SERIF TYPE, AND SHALL BE ACCOMPLISHED WITH GRADE 2 BRAILLE. RAISED CHARACTERS SHALL BE AT LEAST 5/8 IN (16 MM) HIGH, BUT NO HIGHER THAN 2 IN (50 MM). PICTOGRAMS SHALL BE ACCOMPLISHED BY THE EQUIVALENT VERBAL DESCRIPTION PLACED DIRECTLY BELOW THE PICTOGRAM. THE BORDER DIMENSION OF THE PICTOGRAM SHALL BE 6 IN (152 MM) MINIMUM IN HEIGHT. MOUNTING LOCATIONS AND HEIGHT SIGNS SHALL BE INSTALLED ON THE WALL ADJACENT TO THE LATCH SIDE OF THE TOILET RM DOORS. MOUNTING HEIGHT SHALL BE 60 IN. (1525 MM) ABOVE FINISH FLOOR TO THE CENTERLINE OF THE SIGN. (IF LATCHSIDE UNAVAILABLE USE NEAREST ADJACENT WALL FOR SIGN). OWNER TO PROVIDE. IOC CONTRACTOR TO INSTALL OWNER PROVIDED AED SEMI -RECESSED CABINET 1 lA CABINETS AND CASE WORK: SEE ALL DRAWINGS FOR CABINET SIZES, FINISHES, HARDWARE AND MATERIALS SPECIFICATIONS. THE CONTRACTOR SHALL SUBMIT SHOP DRAWINGS FOR APPROVAL PRIOR TO FABRICATION. 1 1 B CABINETS AND CASE WORK PROVIDED BY OWNER, CONTRACTOR TO COORDINATE INSTALLATION W/ OWNER. 1 1 C AT ALL WALLS RECEIVING CABINETS AND CASE WORK, PROVIDE 4'x8'xl /2" FIRE RESISTANT PLYWOOD BACKING ON ALL 4 WALLS. AS REQUIRED. 1 1 D TELCOM CLOSET: PROVIDE AND MOUNT (1) SHEET OF 4' X 8' X 1 /2" FIRE -RETARDANT TREATED BC PLYWOOD WITH TOP AT 8'-0" AFF. AT ALL WALLS. 12A N/A. 12B PROVIDE CAP SHEET FILM TO GLAZING (SOLYX SXWF-WB WHITE BLACK OPAQUE) AT ALL SPANDREL CONDITIONS WHERE INTERIOR WALLS COVER EXTERIOR STOREFRONTS. 15A CONTRACTOR TO INSTALL OWNER PROVIDED SOAP DISPENSERS AT EACH SINK AND LAVATORY. 15B CONTRACTOR TO INSTALL OWNER PROVIDED DIAGNOSTIC BOARDS IN ALL WELLNESS SUITES. CONTRACTOR TO INSTALL DIAGNOSTIC WALL BOARD BRACKET. SEE DET 2/AO.5 FOR DIAGNOSTIC BOARD NICHE. 15C CONTRACTOR TO INSTALL OWNER PROVIDED SHARP CONTAINERS IN ALL WELLNESS SUITES, LAB AND MED ROOM 15D CONTRACTOR TO INSTALL OWNER PROVIDED PAPER TOWEL DISPENSERS AT BREAK ROOM AND COMMUNITY ROOM 15E CONTRACTOR TO INSTALL OWNER PROVIDED REFRIGERATOR LINES FOR ICE MAKERS IN BREAK ROOM 15F CLOSE AND LOCK EXISTING EXTERIOR DOOR. REMOVE LEVER HARDWARE AND CAP. CAULK WITH EXTERIOR RATED BUTYL CAULK. PROVIDE CONTINUOUS BEAD ALL SIDES AND THRESHOLD INTERIOR AND EXTERIOR. 15G PROVIDE RECESSED SPECIMEN PASS -THROUGH CABINET - BOBRICK B-505 CAMPBELL + VAN DUSEN ARCHITECTURE INTERIOR DESIGN www.CVDstudio.com CAMPBELL + VAN DUSEN Design Studio, LLC. 255 South Orange Avenue Suite # 1240 Orlando, Florida 32301 Phone: 407.930.6016 FL. Lic. No. AR0016053 COPY OF THIS PLAN IS NOT VALID UNLESS SIGNED, SEALED AND DATED BY THE ENGINEER OF RECORD J H V) J_ ry CL W E- IV _J J I LJJ LIJ = J m + J U Z •o ry Q W_ L Lj Q > W tV 00 C'7 I", C'r3 CONSTRUCTION DOCUMENTS 03.24.2023 NO, DATE DESCRIPTION 1 08/04/2023 REVISION 1 2 08/25/2023 REVISION 2 A 05/01/2023 ADDENDUM A B 05/03/2023 ADDENDUM B PRINCIPAL IN CHARGE F. CAMPBELL PROJECT MANAGER M.TORRES DIMENSION PLAN TYP. PLAN @ TOILET a2.2 1 /2" = 1'-0" 9'-0" A.F.F. IV — FINISHED FLOOR TYP. ELEVATION @ TOILET 1 /2" = 1'-0" AD SYSTEMS DETAILS N.T.S. I. TYP. ELEVATION @ TOILET 1/2" = 1'-0" �E�e aE��PPaa,wE� i' RE oi�OU llFi io CV I S z aR PP1-1 o� 14" A-3 TYP. SECTION @ TOILET A2.2 1 /2" = 1'-0" 9'-0" A.F.F. FINISHED FLOOR O TOILET SYMBOL LEGEND ALL R/R ACCESSORIES SHALL BE BY BOBRICK WASHROOM EQUIPMENT OR EQUAL, U.N.O., AND SHALL BE STAINLESS STEEL FINISH. MOUNT ALL FIXTURES PER ADAAG REQUIREMENTS. A. KOHLER K-3493-0 HIGHLINE CLASSIC COMFORT HEIGHT TWO-PIECE ELONGATED 1.6 GPF TOILET WHITE WITH KOHLER K-4731-GC-0 STRONGHOLD QUIET CLOSE ELONGATED TOILET SEAT IN WHITE * FLUSH LEVER TO BE ON THE APPROACH SIDE B. KOHLER K-20000-0 CAXTON RECTANGLE UNDER -MOUNT SINK, WHITE C. AMERICAN STANDARD 7502.170.002 DOUBLE HANDLE CENTERSET GOOSENECK BATHROOM FAUCET D. BOBRICK B-6806.99 X 36 ADA 36" GRAB BAR WITH PEENED GRIPPING SURFACE E. BOBRICK B-6806.99 X 42 ADA 42" GRAB BAR WITH PEENED GRIPPING SURFACE F. BOBRICK B-2888 CLASSIC SERIES SURFACE -MOUNTED MULTI -ROLL TOILET TISSUE DISPENSER G. ECOLAB NEXA 9202-1 188 CLASSIC TOUCH FREE SOAP DISPENSER - OWNER FURNISHED, CONTRACTOR INSTALLED. H. EBUN BD11 14 WALL MOUNT PAPER TOWEL DISPENSER, BAMBOO ORIGINAL I. BOBRICK B-165 2436 CHANNEL FRAME MIRROR: 24" X36" J. BOBRICK B-682 SURFACE MOUNTED HAT AND COAT HOOK. MOUNT CENTERED ON DOOR INSIDE RESTROOM STALLS PER ADAAG REQUIREMENTS 5s _ n„ TOILET 105 1/2" = 1'-0" TOILET 120 1/2" = 1'-0" TOILET 103 1 /2" = 1'-0" A. - 171 TOILET 130 1/2" = 1'-0" 7' - 9" H.C.-ACCESSIBLE BATHROOM 60" X 56' CLEAR FLOOR SPACE FOR WATER CLOSET (SIDE APPROACH) 30" X 48" CLEAR FLOOR SPACE FOR LAVATORY 5-0" DIAMETER TURN -AROUND SPACE 30" X 48" ADA TOILET MANEUVERING CLEARANCE TYPICAL H.C. TOILET ELEVATIONS \/I FR P 0 R 24' X 36" ;vIiRROR — NOT rLTE n� rr; 12" 42" MIN 36" MIN 17" MIN MAX 40 GRAB No x 8„ 8 AN 1 m a a < _ MIN E x cD z z < FU S z HANDLE 0PAPER N COVER z_ SHALL BE ; _ OR - ON OPEN INSULATE SIDE of E p GE 0-) — W.C. SIDE ELEVATION TANK (LAV LAV SIDE ELEVATION FRONT ELNXTION SCALE: 1/2" = 1'-0" SCALE: 1/2" = 1'-0" SCALE: 1/2" = 1'-0" GRAB BAR MOUNTING DETAIL GYPSUM WALL BOARD METAL STUDS GRAB BAR 1 1 /2"O 1 1/2" CLEARANCE FROM WALL ANCHOR PLATE 12 GA. STEEL ALT: USE 2X6 WOOD BETWEEN STUDS co co OO F\ TYPICAL HC.HILO EWC MOUNTING DETAIL CLEAR FLOOR 8 1 >> SPACE MIN. z 48"x30" 48" M I N y CENTERED ON I LOWER 1 00 (HANDICAP ACCESSIBLE) z DRINKING I z = �, d �I � FOUNTAIN c r CN ^q N r� SPOUT HEIGHT ELEVATION CLEAR FLOOR SPACE KNEE CLEARANCE AND SPOUT HEIGHT ELEVATION HC-1 HC. MOUNTING DETAIL A.� SCALE N.T.S. CAMPBELL + VAN DUSEN ARCHITECTURE INTERIOR DE5;IQN w.CVDstudio.com CAMPBELL + VAN DUSEN Design Studio, LLC. 255 South Orange Avenue Suite # 1240 Orlando, Florida 32301 Phone: 407.930.6016 FL. Lic. No. AR0016053 ARCHITECT OF RECORD FRANK W. CAMPBELL AIA FL LIC NO. AR0016053 COPY OF THIS PLAN IS NOT VALID UNLESS SIGNED, SEALED AND DATED BY THE ARCHITECT OF RECORD COPY OF THIS PLAN IS NOT VALID UNLESS SIGNED, SEALED AND DATED BY THE ENGINEER OF RECORD J L.L t/) J J OIL = O. Uj F— IV _I J Uj LLJ + J U Z .o Q J = .— O C) LJ__f C1! OL- Q >> > LJJ tV 00 (y) I_- ('7 PRINCIPAL IN CHARGE F. CAMPBELL PROJECT MANAGER M. TORRES .................................. ......... I........................ ADVENT HEALTH WELL 65+ ZEPHYRHILLS 22-0328-01 DETAILS A2.2 LAY -IN PANEL NOM. N CROSS TEE 2' CROS i TEE HANGER WIRE 12 GA MIN. 4' O.C. SECURE TO STRUCTURE W/ POWDER ACTUATED FASTENERS. HILTI X-CX ALH OR EQUAL MAIN BEAM NOTE: MINSTALL PER ASTM 636 MAXIMUM DEFLECTION OF HANGER WIRE IS 1:6. PROVIDE ADDITIONAL SUPPORTS AS REQUIRED. TEGULAR EDGE SUSPENDED CEILING DETAIL STORAGE 1 106 10 n 8 Y 12 GA. HANGER WIRE WRAP WIRE MIN. 3 TIMES IN 3 INCHES 'T' BAR MAIN BEAM SCALE: N.T.S. EXISTING STRUCTURE POWER DRIVEN FASTENERS 12 GA. WIRE HANGERS MAX 6" FROM WALL 12 GA. WIRE HANGERS MAX 4' O.0 10'-0 r ACOUSTICAL CEILING PERIMETER TRIMS WALL CEILING DETAIL SCALE: I" = Y-0" STRUCTURE ABOVE SECURE TRACK TO STRUCTURE - USE POWER DRIVEN FASTENERS AT 24" O.C. (MAX.) 3 5/8" GALV. METAL STUD FRAMING AT 16" O.C. TO STRUCTURE ABOVE 10'-0" A.F.F OIL 1-7 8'-2" A.F.F. HEADER BRACE TO STRUCTURE 10'-0" A.F.F OIL ACOUSTICAL CEILING REFER TO CEILING PLAN FOR HEIGHT x 5/8" GWB W/ CORNER BEAD CEILING DETAIL SCALE: 1 " = 1'-0" 4 Q Q STRUCTURE ABOVE 3 5/8" GALV. METAL STUD FRAMING AT 16" O.C. TO STRUCTURE ABOVE PARTITION SEE PLAN ° 10'-0" A.F.F ACOUSTICAL CEILING REFER TO CEILING PLAN FOR HEIGHT CROWN MOLDING WHERE NOTED IN PLAN; SEE DET. A/A3.0 5/8" DRYWALL (TYP.) 9'-0" A.F.F DRYWALL (TYP. CORNER BEAD (TYP.) WALL :EILING DETAIL SCALE: 1" = 1'-0" T 11 x x STRUCTURE ABOVE SECURE TRACK TO STRUCTURE: USE POWER DRIVEN FASTENERS AT 24" O.C. (MAX.) 3 5/8" GALV. METAL STUD FRAMING AT 16" O.C. TO STRUCTURE ABOVE 10'-0" A.F.F ACOUSTICAL CEILIN 9'-0" A.F.F 77- 5/8" DRYWALL (TYP.) Hx' 5/8" DRYWALL (TYP.) ±9' -2"AFF (CL_5_ CEILING DETAIL A3.0 SCALE: 1" = Y-0" mew OWL LLEC. ROOM/ FIRE RISER INN 104 loom I IN I IN IN I MEN I FAMI Jim, Owl loom 10, N' I ■ rm Norm, L11111 lm7rl 01 Ma p�9'_ 0"A.F.F 11001 4- 115.d F& INEEMENE, 0 FAM"isom !I 'E' ­10 ION FS ERAft ,gs !;a �NLMMWM a Jwr or NMI IWd jr%Aj MEN 'A ims 1 9'- 0"A.F.F BE MIN Elm 0 11 -10 lam Mai INN MEMNON - 'E" pia"Evarm 0 INN I- F=7 bf ho, 111101111 ME 0 0 0 7NI a FM7 1_7 INA WE ormi Wil LM, Fig, M M E 0 M MMMMMMMM MOO" 1006"MMA E'_ uFmourm NNE ONE NONE MENEEMEN 11EMrm a, mno m 10'-O"A.F.F. -OLMOMM _wjU rm-sn'NEEL '1111111walkEENEW MENEEMEMENER.AME MEN 1 REFLECTED CEILING PLAN A3.0 1 /4'1 = 1'-011 B C ACOUSTICAL CLG. TILE CROWN MOLDING FYPON MLD453-16 TYP. CROWN MOLDING DETAIL SCALE: NTS CEILING & LIGHTING LEGEND NEW CEILING GRID WITH 2' x 2' x 5/8" ACOUSTICAL CEILING TILE - MANUFACTURED BY USG - OLYMPIC MICRO TEGULAR, COLOR: WHITE 2' X 2' LAY -IN LED LIGHT IN ACOUSTICAL TILE CEILING GYPSUM BOARD CEILING RECESSED DOWN LIGHT (SEE ELECT. DWGS.) PENDANT MOUNTED FIXTURE (SEE ELECT. DWGS.) Oo DECORATIVE PENDANT (SEE ELECT. DWGS.) 24X24 LOCKABLE ACCESS PANEL. PAINT TO MATCH CEILING SUPPLY DIFFUSER 0 RETURN DIFFUSER r EXHAUST FAN �s NEW SOFFIT / HEADER L• � � J CEILING/SOFFIT HEIGHT FIRE SPRINKLER. REFER TO PLUMBING SHEET FOR LOCATIONS. • EXIT LIGHT, SINGLE FACE. LETTER INDICATES FIXTURE TYPE. BLACK QUADRANT INDICATES DIRECTION OF FACE, ARROW (S) INDICATE DIRECTION OF TRAVEL. SEE ELECTRICAL SHEETS. RECESSED DOWN LIGHT WALL WASHER (SEE ELECT. DWGS.) WALL SCONCE. (SEE ELECT. DWGS.) CROWN MOLDING NOTE: VERIFY AND COORDINATE LIGHTS AND HVAC EQUIPMENT PLACEMENT WITH MECHANICAL AND ELECTRICAL DRAWINGS. REFLECTED CEILING PLAN C1 LIGHTING PLACEMENT IS EXTREMELY IMPORTANT IN SOME ROOMS. IF CONTRACTOR BELIEVES THE CEILING GRID WILL NOT LAYOUT EXACTLY AS DRAWN, ARCHITECT IS TO BE NOTIFIED BEFORE BEGINNING WORK. C2 SOFFITS: GYP BOARD ON FRAMING @ 16" O.C. SUSPENDED FROM STRUCTURE ABOVE OR WALL. VERIFY ALL SOFFIT DIMENSIONS WITH CABINET DWGS, INTERIOR ELEVATIONS OR SECTION DETAILS. C3 PROVIDE & INSTALL SOUND BATT INSULATION ABOVE ACOUSTICAL CEILINGS AT H.C. TOILETS, STAFF RM. & I.T. RM. C4 VERIFY CLIENT'S REQUIREMENTS FOR MUSIC, INTERCOM, VCR/TV LOCATIONS, AND CONNECTIONS TO BASE LOCATIONS. C5 SEE MECHANICAL AND ELECTRICAL PLANS FOR EQUIPMENT AND FIXTURES IN CEILING. IF CONTRACTOR BELIEVES THAT CEILING GRID WILL NOT LAY OUT EXACTLY AS DRAWN, HE SHALL CONTACT ARCHITECT BEFORE BEGINNING WORK. C6 ALL NEW ACOUSTICAL CEILING HT = 10'-0" AFF. U.N.O. C7 TOP OF EXISTING EXTERIOR WINDOWS & WALL = 12'-0" ABBREVIATIONS: AFF ABOVE FINISH FLOOR CLG CEILING EQ EQUAL HDR HEADER POR POINT OF REFERENCE PT PREASSURETREATED TYP TYPICAL N NEW ETR EXISTING TO REMAIN CEILING LAYOUT NOTES: i NOTE: Xs IN ROOMS ARE FOR REFERENCE AND COORDINATION OF CEILING PLACEMENT WITH DRAWING. USE DIMENSIONS, WHERE PRESENT, IN ADDITION TO X. NOTE: VERIFY AND COORDINATE LIGHT SELECTIONS AND HVAC EQUIPMENT PLACEMENT WITH MECHANICAL AND ELECTRICAL. lr ARCHITECTURE INTERIOR DISIGI www.CVDstudio.com CAMPBELL + VAN DUSEN Design Studio, LLC. 255 South Orange Avenue Suite # 1240 Orlando, Florida 32801 Phone: 407.930.6016 FL. Lic. No. AR0016053 •2. 4 ARCHITECT OF RECORD FRANK W. CAMPBELL AIA FL LIC NO. AR0016053 COPY OF THIS PLAN IS NOT VALID UNLESS SIGNED, SEALED AND DATED BY THE ARCHITECT OF RECORD COPY OF THIS PLAN IS NOT VALID UNLESS SIGNED, SEALED AND DATED BY THE ENGINEER OF RECORD J J z O � n = Uj ry F— IV J W W Q = J m U Z -'0 Q W i L Lj _ _ O p w W NO � �O� CONSTRUCTION DOCUMENTS 03.24.2023 NO. DATE DESCRIPTION 1 08/04/2023 REVISION 1 2 08/25/2023 REVISION 2 B OS/03/2023 ADDENDUM B 22-0328-01 REFLECTED CEILING PLAN A3.0 I /A4.0 www.CVDstudio.com CAMPBELL + VAN DUSEN Design Studio, LLC. 255 South Orange Avenue Suite # 1240 Orlando, Florida 32801 Phone: 407.930.6016 FL. Lic. No. AROO 16053 OC7' ARCHITECT OF RECORD FRANK W. CAMPBELL AIA FL LIC NO. AR001 6053 COPY OF THIS PLAN IS NOT VALID UNLESS SIGNED, SEALED AND DATED BY THE ARCHITECT OF RECORD COPY OF THIS PLAN IS NOT VALID UNLESS SIGNED, SEALED AND DATED BY THE ENGINEER OF RECORD H 0 ry F— n n ry LU V) LU < > n u-i JU -j F— z + Lr) -'0 < 0 L-U > = O� ry C) LU 'o Lo 0- < 3> rL-L4, rc 01 1(yy')) CONSTRUCTION DOCUMENTS 03.24.2023 NO. DATE DESCRIPTION 08.04.2023 REVISION 1 08.25.2023 REVISION 2 PRINCIPAL IN CHARGE F. CAMPBELL ................. I ............. .......... ................. PROJECT MANAGER M,TPRRES ......................................................... ADVENT HEALTH WELL 65+ ZEPHYRHILLS 22-0328-01 FINISH PLAN A4.0 PLAN LEGEND: CEILING FLOORING, WALL BASE AND TRANSITION STRIPS PAINT, WALLCOVERING AND WALL TILE SURFACES CL1 CEILING TYPE I BVl VINYL WALL BASE - I WV9 WALLCOVERING QZ2] QUARTZ U RFACE COUNTERTOP - 2 OUR ACOUSTICAL CEILING TILE AND GRID SYS CEILING MANUFACTURER: ROPPE DISTRIBUTOR: NATIONAL SOLUTIONS RLID MMANUFA DA TILE MANUFACTURER: USG r WALL I BASE STYLE: SIMPLICITY BOLD PV4005 PATTERN: PAVE COLOR: SIMPLY WHITE NQ76 STYLE: OLYMPIC MICRO TEGULAR COLOR: 194 BURNT UMBER COLOR: BEVELED GLASS Y46285PV FINISH: POLISHED COLOR: WHITE TILES AND WHITE GRID LFLOORI SIZE: 4-1/2" HIGH WIDTH: 54" THICKNESS: 3 CM SIZE: 2' X 2' X 5/8" LOCATION: AS INDICATED; ON MILLWORK BASE CABINETS LOCATION: AS INDICATED ON PLAN EDGE PROFILE: EASED EDGE CEILING TYPE 2 AT FINISHED FLOOR NOTES: MICROPERFORATE WHEN INSTALLED ON EXTERIOR WALL. LOCATION: PROVIDER & HUDDLE COUNTERTOPS CL2 DRYWALL CEILINGS AND SOFFITS NOTES: PROVIDE PRE -FORMED CORNERS. PROVIDE IN 120' CONTINUOUS CONTACT KATIE HANNIGAN T (407)446-5043 OR NOTES: 2" CORNER FOR COUNTER TOPS. CONTACT LORI FINISH: PT1 COILS. KATIE.HANNIGAN@NATIONALSOLUTIONS.COM SCHWARTZ AT (407)716-6447 OR LORI.SCHWARTZ@DALTILE.COM BV2 VINYL WALL BASE - 2 MANUFACTURER: JOHNSONITE WV16 WALLCOVERING - 10 DISTRIBUTOR: NATIONAL SOLUTIONS SS3 SOLID SURFACE COUNTERTOP - 3 FLOORING, WALL BASE AND TRANSITION STRIPS MANUFACTURER: CORIAN STYLE: TRADITIONAL WALL BASE PATTERN: PAVE COLOR: SPARKLING WHITE LVTI LUXURY VINYL COMPOSITION TILE - 1 COLOR: TBS SIZE: 4" HIGH, 1 /8" THICK COLOR: CLAY MASK Y47322PV FINISH: POLISHED MANUFACTURER: SHAW CONTRACT WIDTH: 54" THICKNESS: 1/2" COVER 4 LOCATION; AS INDICATED LOCATION: AS INDICATED ON PLAN E:STYLE: EDGE PROFILE: EASED EDGE ❑ COLOR: PRESERVVEE 07067 NOTES: PROVIDE IN 120' CONTINUOUS COILS. PROVIDE PRE -FORMED NOTES: MICROPERFORATE WHEN INSTALLED ON EXTERIOR WALL. LOCATION: PROVIDED BY MIDMARK- WELLNESS SUITE COUNTEROPS SIZE: 7" X 59" CORNERS. TO ORDER CONTACT KELLI RUSSELL AT (407)280-9531 OR CONTACT KATIE HANNIGAN AT (407)446-5043 OR NOTES: 2" CORNER FOR COUNTER TOPS INSTALL PATTERN: STAGGER KELLI.RUSSELL@TARKETT.COM KATIE. HANNIGAN@NATIONALSOLUTIONS.COM LOCATION: AS INDICATED ON PLAN. WALL TILE 1 NOTES: INSTALL PER MANUFACTURER'S REQUIREMENTS. USE A SHAW WT1 DISTRIBUTOR: CERAMIC TECHNICS LTD SS4 SOLID SURFACE COUNTERTOP - 4 MANUFACTURED/APPROVED ADHESIVE. INSTALL A TRANSITION STRIP AT ALL STYLE: STUDIO MARMI METRO MANUFACTURER: CORIAN FLOORING TRANSITIONS. CONTACT VIRNA MITCHELL AT TRANSITION STRIP - 1 COLOR: FLAVUS COLOR: WEATHERED CONCRETE VIRNA.MITCHELL@SHAWCONTRACT.COM OR (407)405-0422 TS1 MANUFACTURER: SCHLUTER SYSTEMS SIZE: 4"X12" FINISH: POLISHED THICKNESS: 1 LUXURY VINYL COMPOSITION TILE - 2 SIZE: TO BE DETERMINED BY INSTALLER GROUT: LATICRETE 89 SMOKE E: EDGE PROFILE: EASED EDGE LVT2 MANUFACTURER: SHAW CONTRACT COLOR: LOCATION: AS NOTED ON PLAN - LVT TO FT GROUT JOINT WIDTH: 1/8" INSTALL PATTERN: HORIZONTAL BRICK LOCATION: AS INDICATED ON PLAN STYLE: COVER 4140V COLOR: SECURE 07068 NOTES: CONFIRM PROFILE IS APPROPRIATE FOR APPLICATION &PER ADAAG. LOCATION: AS INDICATED ON PLAN NOTES: 2" CORNER FOR COUNTER TOPS SIZE: 7" X 59" TS2 TRANSITION STRIP - 2 NOTES: TO ORDER CONTACT JACQUI ANTLEY AT (407)312-5597 OR JANTLEY@CERAMICTECHNICS.COM INSTALL PATTERN: STAGGER MANUFACTURER: LOCATION: AS INDICATED ON PLAN. SIZE: TO BE DETERMINED BY INSTALLER NOTES: INSTALL PER MANUFACTURER'S REQUIREMENTS. USE A SHAW COLOR: WT2 WALL TILE 2 MANUFACTURED/APPROVED ADHESIVE. INSTALL A TRANSITION STRIP AT ALL LOCATION: AS NOTED ON PLAN - LVT TO VCT DISTRIBUTOR: TILEBAR FLOORING TRANSITIONS. CONTACT VIRNA MITCHELL AT NOTES: CONFIRM PROFILE IS APPROPRIATE FOR APPLICATION & PER ADAAG. MANUFACTURER: SOHO STUDIO VIRNA.MITCHELL@SHAWCONTRACT.COM OR (407)405-0422 TRANSITION STRIP - 3 STYLE: ALCHIMIA TLCFALCMBLU3X12 TS3 MANUFACTURER: COLOR: ALCHIMIA BLUE ALL WINDOW TREATMENT WILL BE MECHO 1-3 %OPACITY MANUAL ROLLER SHADE FINISH PATTERN KEY: SIZE: TO BE DETERMINED BY INSTALLER COLOR: SIZE: 3"X12" GROUT: LATICRETE 35 MOCHA CPT1 CARPET TILE - 1 GROUT JOINT WIDTH: 1/8" ❑ CI CICOLLECTION: MANUFACTURER: SHAW COLLECTIVE LOCATION: AS NOTED ON PLAN - LVT TO CPT NOTES: CONFIRM PROFILE IS APPROPRIATE FOR APPLICATION &PER ADAAG. INSTALL PATTERN: HORIZONTAL BRICK I LOCATION: AS INDICATED ON PLAN FINISH PATTERN KEY:WT3 WALL TILE 3 -TOILET 105 & 130-FLOOR TO CEILING 0 o a DESIGN: SIDE BY SIDE 5T452 NOTES: TO ORDER CONTACT DIANE ARNN AT (689)216-2468 LAY DIRECTION INDICATOR COLOR: TOGETHER 50210 OR DARNN@TILEBAR.COM SIZE: 18"X 36" WALL TILE 3 INSTALL PATTERN: ASHLAR WT3 I LVTI /2 LUXURY VINYL TILE 1 & 2 - STAGGER LOCATION: AS INDICATED ON PLAN. DISTRIBUTOR: TILEBAR NOTES: INSTALL PER MANUFACTURER'S REQUIREMENTS. USE SHAW MANUFACTURER: WOW PAINT, WALLCOVERING AND WALL TILE MANUFACTURED/APPROVED ADHESIVE. INSTALL A TRANSITION STRIP AT ALL STYLE: TRAPEZIUM FLOORING TRANSITIONS. ICE WHITE MATT PAINT- 1 SIZE:4"X9" PT1 MANUFACTURER: SHERWIN WILLIAMS GROUT: LATICRETE 44 BRIGHT WHITE; LATICRETE SMOKE 89 (WHEN MIXED CARPET TILE - 2 COLOR: NATURAL CHOICE SW7011 WITH WT4) CPT2 MANUFACTURER: MILLIKEN SHEEN: EGGSHELL GROUT JOINT WIDTH: 1/8" 0 COLLECTION: EDGE KIT LOCATION: THROUGHOUT U.N.O. INSTALL PATTERN: SEE FINISH PATTERN KEY 00o DESIGN: EDGE LIT LOCATION: FLOOR TO CEILING AS INDICATED ON PLAN 0 RCU COLOR: MERCURY EDG107-133 PTl A PAINT - 1 A MANUFACTURER: SHERWIN WILLIAMS NOTES: TO ORDER CONTACT DIANE ARNN AT (689)216-2468 OR DARNN@TILEBAR.COM WT3&4 WALL TILE 3&4 - TOILET 103- FLOOR TO CEILING SIZE: 9.X INSTALL PATTERN: ASHLAR COLOR: NATURAL CHOICE SW7011 WT4 WALL TILE 4 CPT2-5 - CARPET TILE 2-5 - ASHLAR LOCATION: AS INDICATED ON PLAN. SHEEN: SEMI -GLOSS DISTRIBUTOR: TILEBAR NOTES: 30% OF OVERALL PATTERN WHEN INSTALLED WITH CPT3. INSTALL PER LOCATION: DOOR FRAMES THROUGHOUT PAINT 2 MANUFACTURER: WOW MANUFACTURER'S REQUIREMENTS. USE A MILLIKEN PT2 - MANUFACTURER: SHERWIN WILLIAMS STYLE: H COLOR: ASHY GREY MATT MANUFACTURED/APPROVED ADHESIVE. INSTALL A TRANSITION STRIP AT ALL COLOR: EXTRA WHITE SW7006 SIZE: FLOORING TRANSITIONS, CONTACT ROSIE STERLING AT SHEEN: EGGSHELL T: L T: L GROUT: SMOKE 89 ROSIE.STERLING@MILLIKEN.COM OR (407)580-7909 LOCATION: TRIM GROUT JOINT WIDTH: 1/8" CPT3 CARPET TILE - 3 PAINT 3 INSTALL PATTERN: SEE FINISH PATTERN KEY MANUFACTURER: MILLIKEN PT3 - COLLECTION: EDGE LIT MANUFACTURER: SHERWIN WILLIAMS LOCATION: AS INDICATED ON PLAN X,� o°o o DESIGN: EDGE LIT COLOR: BIG CHILL SW 7648 NOTES: TO ORDER CONTACT DIANE ARNN AT (689)216-2468 00o COLOR: EDG259-120 ARGON SHEEN: EGGSHELL OR DARNN@TILEBAR.COM SIZE: 9.85" X 39.4" LOCATION: AS INDICATED ON PLAN. CG1 CORNER GUARD 1 INSTALL PATTERN: ASHLAR PT4 PAINT - 4 MANUFACTUER: CONSTRUCTION SPECIALTIES WT3 WALL TILE 3 - TOILET 120- FLOOR TO CEILING LOCATION: AS INDICATED ON PLAN. MANUFACTURER: SHERWIN WILLIAMS PRODUCT NAME: ACROVYN NOTES: 70% OF OVERALL PATTERN WHEN INSTALLED WITH CPT2. INSTALL PER COLOR: TARNISHED TRUMPET SW 9026 COLLECTION: SUEDE MANUFACTURER'S REQUIREMENTS. USE A MILLIKEN SHEEN: EGGSHELL WING AT 90 DEGREE CORNERS (VA-024N) MANUFACTURED/APPROVED ADHESIVE. INSTALL A TRANSITION STRIP AT ALL LOCATION: ACCENT WHERE INDICATED 1-1/2" WING @ ANGLES OTHER THAN 90 DEGREES (VA-200MN) FTI FLOOR TILE 1 - 1 /3 OFFSET ZX FLOORING TRANSITIONS. CONTACT ROSIE STERLING AT WALLCOVERING - 1 COLOR: EGGSHELL # 100 ROSIE.STERLING@MILLIKEN.COM OR (407)580-7909 WV1 MANUFACTURER: COMMAND SIZE: 8'-0" LENGTHS CPT4 CARPET TILE - 4 2 COLLECTION: DENSHO PATTERN: CM139-2708 LOCATION: AS INDICATED ON PLAN NOTES: PROVIDE NO TAPE VERSION AND INSTALL WITH ADHESIVE IN MANUFACTURER: MILLIKEN COLLECTION: COMFORTABLE CONCRETE COLOR: OATMEAL THE FIELD. CONTACT KELSEY TRACY AT (813)831-3344 OR 17 DESIGN: URBAN SKETCH WIDTH: 52" KTRACY@CAS-CORP.COM COLOR: URS 180-153 OYSTER SHELL LOCATION: AS INDICATED ON PLAN NOTES: MICROPERFORATE WHEN INSTALLED EXTERIOR WALL. FRP ENGINEERED PVC FREE RIGID SHEET SIZE: 19.7" X 19.7 MANUFACTURER: CONSTRUCTION SPECIALTIES INSTALL PATTERN: TBD HANNIGAN CONTACT KATIE HANNIGAN AT 3 OR 3 PRODUCT NAME: CS ACROVYN 4000 SHEET LOCATION: AS INDICATED ON PLAN. LUTIONS.0 KATIE.HANNIGAN@NATIONA LSOLUTIONS.COM COLOR: EGGSHELL # 100 NOTES: INSTALL PER MANUFACTURER'S REQUIREMENTS. USE A MILLIKEN WV2 MANUFACTURERERING: - 2 MANUFACTURER: COMMAND TEXTURE: STANDARD SUEDE TEXTURE MANUFACTURED/APPROVED ADHESIVE. INSTALL A TRANSITION STRIP AT ALL COLLECTION: DENSHO SIZE: 4' X 8' (0.040" THICK) FLOORING TRANSITIONS. CONTACT ROSIE STERLING AT ROSIE.STERLING@MILLIKEN.COM OR (407)580-7909 z PATTERN: CM139-2715 LOCATION: AS INDICATED ON PLAN GENERAL PLAN NOTES: O COLOR: LOCAMOTIVE NOTES: INSTALL WITH MATCHED VINYL TRIM MOULDINGS VCT2 VINYL COMPOSITION TILE 2 - STACKED CPTS CARPET TILE 5 MANUFACTURER: MILLIKEN WIDTH: 52" VERTICAL ORIENTATION. INSTALL WITH ADHESIVE IN THE FIELD. LOCATION: AS INDICATED ON PLAN INSTALL TO 4' AFF CONTACT KELSEY TRACY AT (813)831-3344 MCOLLECTION: COMFORTABLE CONCRETE NOTES: MICROPERFORATE WHEN INSTALLED ON EXTERIOR WALL. DESIGN: URBAN VISTA CONTACT KATIE HANNIGAN AT (407)446-5043 OR OR KTRACY@CAS-CORP.COM COLOR: URV05-219-180 PARCHED SAND KATIE.HANNIGAN@NATIONALSOLUTIONS.COM WEl WALL EDGE - 1 SIZE: 19.7" X 19.7" MANUFACTURER: SCHLUTER SYSTEMS INSTALL PATTERN: ASHLAR WV3 WALLCOVERING - 3 STYLE: JOLLY LOCATION: AS INDICATED ON PLAN. DISTRIBUTOR: NATIONAL SOLUTIONS COLOR: STAINLESS STEEL BRUSHED 304 NOTES: 10% OF OVERALL PATTERN WHEN USED WITH CPT6. INSTALL PER PATTERN: PAVE SIZE: TO BE DETERMINED BY INSTALLER MANUFACTURER'S REQUIREMENTS. USE A MILLIKEN COLOR: METALLO Y46289PV LOCATION: EXPOSED EDGE OF WALL TILES 1 & 2 MANUFACTURED/APPROVED ADHESIVE. INSTALL A TRANSITION STRIP AT ALL WIDTH: 54" NOTES: TO ORDER CONTACT MATT LONG AT (407)795-0794 OR FLOORING TRANSITIONS. CONTACT ROSIE STERLING AT LOCATION: AS INDICATED ON PLAN MLONG@SCHLUTER.COM ROSIE.STERLING@MILLIKEN.COM OR (407)580-7909 NOTES: MICROPERFORATE WHEN INSTALLED ON EXTERIOR WALL. GLASS FILM FOR HUDDLE ROOM ALLOWANCE $10 000 1. NOTIFY THE ARCHITECT REGARDING ANY DISCREPANCIES PRIOR TO PROCEEDING WITH THE WORK. 2. ALL INTERIOR WALL AND CEILING FINISHES SHALL BE NOT LESS THAN CLASS C (0.22 WATTS/CM SQ.) FOR MINIMUM CRITICAL FLUX IN ACCORDANCE WITH NFPA 101 AND MEET FLAME SPREAD REQUIREMENTS AND SMOKE DEVELOPMENT IN ACCORDANCE WITH ASTM E-84 PER TABLE LISTED BELOW. PROVIDE PRODUCT CERTIFICATIONS TO AUTHORITY HAVING JURISDICTION FOR PROOF OF COMPLIANCE. CONTACT KATIE HANNIGAN AT (407)4465043 OR GF 3. CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR THE ACCURACY OF THE CPT6 - CARPET TILE - 6 CONTRACTOR'S MEASUREMENTS AND TOTAL YARDAGE REQUIREMENTS TO BE MANUFACTURER: MILLIKEN KATIE.HANNIGAN@NATIONALSOLUTIONS.COM WTI WALL TILE 1 - COMMUNITY -HORIZONTAL BRICK FURNISHED. NO REQUESTS FOR MATERIALS OR INSTALLATION EXTRAS WILL BE COLLECTION: COMFORTABLE CONCRETE WV4 WALLCOVERING - 4 CONSIDERED DUE TO MEASUREMENT OR TAKEOFF ERRORS BY CONTRACTOR. DESIGN: URBAN SKETCH DISTRIBUTOR: NATIONAL SOLUTIONS COLOR: URS265-106 FADED ANCHOR PATTERN: PAVE 4. ALL MISCELLANEOUS GRILLES, PLATES, OR OTHER DEVICES SHALL BE PAINTED TO SIZE: 19.7" X 19.7" COLOR: BIRCH Y46288PV MATCH THE WALL OR CEILING IN WHICH THEY ARE INSTALLED, U.N.O. INSTALL PATTERN: ASHLAR WIDTH: 54" LOCATION: AS INDICATED ON PLAN. LOCATION: AS INDICATED ON PLAN 5. PROVIDE TRANSITION STRIPS AT ALL FLOORING MATERIAL CHANGES. TRANSITIONS NOTES: 907 OF OVERALL PATTERN WHEN USED WITH CPT5. INSTALL PER NOTES: MICROPERFORATE WHEN INSTALLED ON EXTERIOR WALL. SURFACES IN DOOR THRESHOLDS SHALL BE CENTERED DIRECTLY UNDER DOOR. FURNISH MANUFACTURER'S REQUIREMENTS. USE A MILLIKEN CONTACT KATIE HANNIGAN AT (407)446-5043 OR COLOR SAMPLES FOR REVIEW PRIOR TO INSTALLATION. MANUFACTURED/APPROVED ADHESIVE. INSTALL A TRANSITION STRIP AT ALL KATIE. HANNIGAN@NATIONALSOLUTIONS.COM PL1 PLASTIC LAMINATE - 1 FLOORING TRANSITIONS. CONTACT ROSIE STERLING AT MANUFACTURER: WILSONART 6. PROVIDE TO CAMPBELL + VAN DUSEN DESIGN STUDIO COLOR SAMPLES OF ALL ER ROSIE.STERLING@MILLIKEN.COM OR (407)580-7909 WV5COV WA DISTRIBUTOR: NG - 5 COLOR: VERANDA TEAK 8209K-28 NATIONAL SOLUTIONS FINISH: GLOSS LINE FINISH WITH AEON DISTRRIBUTOFINISHES AND MATERIALS FOR VERIFICATION AND REVIEW PRIOR TO INSTALLATION. FT1 FLOOR TILE - 1 PATTERN: PAVE HANG ORIENTATION: HORIZONTAL 7. FURNISH ATTIC STOCK OF 5% OVERAGE OF ALL WALL COVERING AND FLOORING DISTRIBUTOR: TRINITY TILE COLOR: MARSH ROOT Y46292PV LOCATION: COMMUNITY, BREAKROOM LOWER CABINETS FINISHES, NOT LESS THAN 10 YARDS OF EACH TYPE OF CARPET AND NOT LESS THAN SERIES: SOCIAL WIDTH: 54" NOTES: CONTACT MEGHAN RAWLINS ENGER AT (407)832-5388 20 SQUARE FEET OF EACH TYPE OF RESILIENT FLOORING. COLOR: GRAY LAKE LOCATION: AS INDICATED ON PLAN OR RAWLINM@WILSONART.COM WT2 WALL TILE 2 - BREAKROOM- HORIZONTAL BRICK SIZE: 12" X 24" NOTES: MICROPERFORATE WHEN INSTALLED ON EXTERIOR WALL. 8. FLOORING INSTALLATION SHALL BE COORDINATED WITH OWNER REPRESENTATIVE. GROUT: MAPEI 02 PEWTER CONTACT KATIE HANNIGAN AT (407)446-5043 OR pL2 PLASTIC LAMINATE - 2 PRIOR NOTICE OF ANY EXISTING FIELD CONDITIONS THAT MAY POSE A PROBLEM GROUT JOINT WIDTH: 1/8" KATIE.HANNIGAN@NATIONALSOLUTIONS.COM MANUFACTURER: WILSONART FOR INSTALLATION SHALL BE GIVEN IN A TIMELY MANNER. INSTALL PATTERN: 1 /3 OFFSET COLOR: CRISP LINEN 4942-38 LOCATION: RESTROOM FLOOR TILE AS NOTED ON PLAN WV6 WALLCOVERING - b FINISH: FINE VELVET FINISH NOTES: SEAL GROUT. INSTALL A TRANSITION STRIP AT ALL FLOOR DISTRIBUTOR: NATIONAL SOLUTIONS HANG ORIENTATION: HORIZONTAL 11. PRE -PLAN CARPET SEAMING SO AS TO PROVIDE UNIFORM DIRECTION OF PATTERN TRANSITIONS. TO ORDER CONTACT JENNIFER HORNING AT (321) 231-2181 LOCATION: COMUNITY &BREAK ROOM UPPER CABINETS PATTERN: PAVE AND LAY OF PILE. LOCATION OF SEAMS SHALL BE CENTERED UNDER DOORS AND COLOR: MILLION DOLLAR BEIGE Y46303PV WITHOUT SEAMS IN THE DIRECTION OF TRAVEL. SUBMIT SEAMING DIAGRAM FOR OR JHORNING@TRINITYSURFACES.COM WIDTH: 54" NOTES: CONTACT MEGHAN RAWLINS ENGER AT (407)832-5388 REVIEW PRIOR TO PLACEMENT OF ORDER. VCT1 VINYL SHEET 1 LOCATION: AS INDICATED ON PLAN OR RAWLINM@WILSONART.COM MANUFACTURER: SHAW CONTRACT NOTES: MICROPERFORATE WHEN INSTALLED ON EXTERIOR WALL. 12. TEST CONCRETE SUBSTRATES FOR IRH (INTERNAL RELATIVE HUMIDITY) ACCORDING LASTYLE: VITALITY SHEET CONTACT KATIE HANNIGAN AT (407)446-5043 OR PL3 PLASTIC LAMINATE - 3 TO ASTM F 2170. CONFIRM MOISTURE CONTENT SUITABLE FOR INSTALLATION OF COLOR: RESTORE 73518 KATIE.HANNIGAN@NATIONALSOLUTIONS.COM MANUFACTURER: WILSONART SIZE: 6.58' X 65.94' COLOR: PORTICO TEAK 821 OK-28 LOCATION: AS INDICATED ON PLAN. WV7 WALLCOVERING - 7 FLOORING PER MANUFACTURERS RECOMMENDATIONS. FINISH: GLOSS LINE FINISH WITH AEON NOTES: INSTALL PER MANUFACTURER'S REQUIREMENTS. INSTALL A DISTRIBUTOR: NATIONAL SOLUTIONS HANG ORIENTATION: HORIZONTAL 13. MATCH EXISTING STOREFRONT SYSTEM. TRANSITION STRIP AT ALL FLOORING TRANSITIONS. CONTACT VIRNA PATTERN: PAVE LOCATION: PROVIDER & HUDDLE MITCHELL AT VIRNA.MITCHELL@SHAWCONTRACT.COM OR (407)405-0422. COLOR: WHITE GRASS Y46294PV NOTES: CONTACT MEGHAN RAWLINS ENGER AT (407)832-5388 WIDTH: 54" OR RAWLINM@WILSONART.COM 14. BUILD UP CARPET TO BE FLUSH WITH LVT. VCT2 VINYL COMPOSITION TILE 2 LOCATION: AS INDICATED ON PLAN MANUFACTURER: ARMSTRONG FLOORING NOTES: CONTACT KATIE HANNIGAN AT (407)446-5043 OR STYLE: STANDARD EXCELON IMPERIAL TEXTURE KATIE.HANNIGAN@NATIONALSOLUTIONS.COM QZ1 QUARTZ SOLID RDALA TI COUNTERTOP - 1 INTERIOR WALL AND CEILING FINISH REQUIREMENTS RAO COLOR: BLUE/GRAY 51903 MANUFACTURER: ELE WV8 WALLCOVERING - 8 COLOR: GOLDEN GATE OQ37 SIZE: 12"X12" DISTRIBUTOR: NATIONAL SOLUTIONS FINISH: POLISHED GROUP EXIT ENCLOSURES & CORRIDORS ROOMS & ENCLOSED INSTALL PATTERN: STRAIGHT PATTERN: PAVE THICKNESS: 3 CM EXIT PASSAGEWAYS SPACES LOCATION: AS INDICATED ON PLAN. COLOR: GREAT LAKE Y47320PV EDGE PROFILE: EASED EDGE NOTES: INSTALL PER MANUFACTURER'S REQUIREMENTS. PROVIDE WIDTH: 54" LOCATION: COMMUNITY AND BREAKROOM COUNTERTOPS BUSINESS B C C APPROPRIATE FLOOR SEALER. INSTALL A TRANSITION STRIP AT ALL FLOORING LOCATION: AS INDICATED ON PLAN 2" CORNER FOR COUNTER TOPS. CONTACT LORI TRANSITIONS. CONTACT WILLIAM I. WISE AT (803)728-7077 OR NOTES: CONTACT KATIE HANNIGAN AT (407)446-5043 OR SCHWARTZ AT (407)716-6447 OR LORI.SCHWARTZ@DALTILE.COM (PER FBC 2020 803.11) WIWISE@ARMSTRONGFLOORING.COM. KATIE.HANNIGAN@NATIONALSOLUTIONS.COM 1 /A4.1 T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T TIT T T T T T www.CVDstudio.com CAMPBELL + VAN DUSEN Design Studio, LLC. 255 South Orange Avenue Suite # 1240 Orlando, Florida 32801 Phone: 407.930.6016 FL. Lic. No. AR0016053 ARCHITECT OF RECORD FRANK W. CAMPBELL AIA FL LIC NO. AR0016053 COPY OF THIS PLAN IS NOT VALID UNLESS SIGNED, SEALED AND DATED BY THE ARCHITECT OF RECORD COPY OF THIS PLAN IS NOT VALID UNLESS SIGNED, SEALED AND DATED BY THE ENGINEER OF RECORD J Z J O = ry F n (� = W U IV U Q � U _! _t CD ULLj I--- Q LLJ J 0 0 L U 'O Lo <C 3: U N � Cr) CONSTRUCTION DOCUMENTS 03.24.2023 NO. DATE DESCRIPTION 08.04.2023 REVISION 1 08.25.2023 REVISION 2 PRINCIPAL IN CHARGE F. CAMPBELL PROJECT MANAGER M, TQRRES........................................................ . ADVENT HEALTH WELL 65+ ZEPHYRHILLS 22-0328-01 FINISH PLAN LEGEND A4.1 I ELEVATION 1 /2t1 = 11-011 HUDDLE ROOM CLG 2'-0"CT 00, Qz2 HIDDEN SUPPORT BRACKET 6'-0" OPEN KNEE SPACE / / 10 O ' O / /6'-0" SOFFIT 2'-0"CT \ / , \ ` / / / / / Qz2 1 N O SPACE EE SUPPORT / 1=1 1=\/AT1r)K1 fnl I -II innl I` Rf1t1N1 1 /2" = 11-011 SECTION_(( 1 /2" = 11-011 CLG SOFFIT PRINTER/COPIER HUDDLE ELEVATION @ HUDDLE ROOM 1 /211 = 1 1-011 CABINET ABBREVIATIONS: AS ADJUSTABLE SHELVES BC BASE CABINET BD BAFFLE DIVIDER BS BACK SPLASH CT COUNTER TOP DW DRAWER FD DRAWER FOR HANGING FILES FS FIXED SHELVES ID INSIDEDIMENSION KS KNEE SPACE OS OPEN SHELF PG PLASTIC GROMMET FOR WIRE ACCESS PW PULL-OUT WASTE SH SHELF/SHELVES SP SINK PANEL TS TOE SPACE 4" TYP. UC UPPER CABINET I NI tO a zo I CLG 0 i0 SOFFIT 2' - 0" CT 9' - 6" / 9' - 6" 2' - 0" CT / / , ' ` / / / / 00 o N Qz2 Qz2 � � � a HIDDEN SUPPORT BRACKET OPEN KNEE SPACE OPEN KNEE SPACE OPEN KNEE SPACE OPEN KNEE SPACE HIDDEN SUPPORT BRACKET / ELEVATION @ HUDDLE ROOM 1 /211= 11-011 SECTION @ HUDDLE 1 /2" = 11-011 CAMPBELL + VAN DUSEN Design Studio, LLC. 255 South Orange Avenue Suite # 1240 Orlando, Florida 32801 Phone: 407.930.6016 FL, Lic. No. AR0016053 v ARCHITECT OF RECORD FRANK W. CAMPBELL AIA FL LIC NO. AR0016053 COPY OF THIS PLAN IS NOT VALID UNLESS SIGNED, SEALED AND DATED BY THE ARCHITECT OF RECORD COPY OF THIS PLAN IS NOT VALID UNLESS SIGNED, SEALED AND DATED BY THE ENGINEER OF RECORD I Ll- cn J J_ CY = W E— IV J � LLI LLI J = J m _ + J Z Q De Q i O (-) W 0— C)zW L3._ Q r-4 p( i--1 (r) PRINCIPAL IN CHARGE F. CAMPBELL ..................................................................... PROJECT MANAGER M. TORRES .................................................................... ADVENT HEALTH WELL 65+ ZEPHYRHILLS 22-0328-0 l MILLWORK A5.1 VC V �Vvl /B\ SANITARY WASTE RISER DIAGRAM NTS UNZ off PICO GENERAL NOTES: 1. CONTRACTOR SHALL VISIT THE SITE PRIOR TO BIDDING AND CONSTRUCTION TO SURVEY EXISTING CONDITIONS. 2. CONTRACTOR SHALL INSTALL APPLIANCES PER MANUFACTURER'S PLUMBING REQUIREMENTS. 3. CONTRACTOR SHALL COORDINATE THE SANITARY VENTING WITH THE EXISTING VTR'S ((1) 3- & (1) 2-) PROVIDED IN THE SHELL PACKAGE. IF THE EXISTING VTR'S ARE WITHIN 10'-0" OF THE RTU OUTSIDE AIR INTAKES THE CONTRACTOR SHALL COORDINATE NEW LOCATIONS. KEY NOTES: CONTRACTOR SHALL TIE NEW 3- SANITARY WASTE LINE INTO NEAREST EXISTING SANITARY LINE OF ADEQUATE SIZE. PROVIDE 3" VENT THRU ROOF. CONTRACTOR SHALL COORDINATE EXACT LOCATION WITH ROOFTOP AIR HANDLING UNITS TO MAINTAIN A MINIMUM OF 10'-0" CLEARANCE BETWEEN THE VENT AND THE ROOFTOP UNIT'S OUTSIDE AIR INTAKE. FIXTURES PIPE SIZE FIXTURE SAN SIZE VENT SIZE WATER CLOSET 3" 2 LAV / SINK 3" 1-1/2- ELECT WATER COOLER 3" 1-1/2- FLOOR DRAIN 3" 2" NOTE: PLUMBING CONTRACTOR SHALL FIELD VERIFY, USING SUCH METHODS AS A SEWER CAMERA, LOW FREQUENCY GPR (GROUND PENETRATING RADAR) OR EM (ELECTROMAGNETIC) UTILITY LOCATING METHODS DURING DEMOLITION PHASE OF PROJECT TO DETERMINE THE EXACT CONDITION OF PIPE, LOCATION, SIZE, INVERT AND DIREC11ON OF FLOW OF ALL EXISTING SANITARY/GREASE WASTE LINES WITHIN SCOPE OF PROJECT. DISCREPANCIES AND UNFORESEEN CONDITIONS ARE TO BE BROUGHT TO THE ATTENTION OF THE OWNER, ARCHITECT AND PROJECT ENGINEER PRIOR TO PROCEEDING WITH DEMOLITION IN THE AREA OF CONCERN. CAMPBELL + VAN DUSEN ARCHITECTURE INTERIOR DESIGN www.CVDstudio.com CAMPBELL + VAN DUSEN Design Studio, LLC. 255 South Orange Avenue Suite # 1240 Orlando, Florida 32801 Phone: 407.930.6016 FL. Lic. No. AA26003339 ARCHITECT OF RECORD FRANK W. CAMPBELL AIA FL LIC NO. AROO 16053 COPY OF THIS PLAN 15 NOT VALID UNLESS SIGNED, SEALED AND DATED BY THE ARCHITECT OF RECORD \px11II11j/// \,qR JAp 0. is CO OP A. 01?/DA 0- Taylor J. Lewis, PE, FL Reg. No. 90018 COPY OF THIS PLAN IS NOT VALID UNLESS SIGNED, SEALED AND DATED BY THE ENGINEER OF RECORD I Lj- 0 r'-4 ry I U < 0 L/) L.Lj L1J > I co I-- F— + Lr) T (-) = ---0 rl.*, < LU LLJ 0 -10 1- L11 �-o L0 0!!� < 3�: or-0, X ru--4j (1yo) CONSTRUCTION DOCUMENTS 03.24.2023 PRINCIPAL IN CHARGE F. CAMPBELL ..................... ......... ........... .......... ........ PROJECT MANAGER M. TORRES ............... I ....................... ........... ........ ADVENT HEALTH WELL 65+ ZEPHYRHILLS 22-0328-01 MEP CONSULTING SANITARY WASTE ENGINEERS SINCE 1977 RISER DIAGRAM FL REG NO. 3089 2016 ALDEN RD. ORLANDO, FL 32803 (407) 246-1688 WWW.PEIRACOM P3* I PEI PROXCT 22121 rio (9 LIGHTING RENOVATION PLAN 1/811 � 1 1-011 GENERAL LIGHTING NOTES 1 . PULL UNSWITCHED HOT CONDUCTOR FROM LOCAL LIGHTING CIRCUIT TO EMERGENCY EGRESS LIGHTS. RUN 3 #12 - 1 #12 GND - 3/4"C TO INCLUDE UNSWITCHED CONDUCTOR. 2. PULL UNSWITCHED HOT CONDUCTOR FROM LOCAL LIGHTING CIRCUIT TO EXIT SIGNS. RUN 2 # 12 - I # 12 GND - 3/4"C. 3. LIGHT FIXTURES BEING REUSED SHALL BE REPAIRED, CLEANED AND RELAMPED. 4. SWITCHES SHALL BE GANGED WHEN THEY APPEAR ADJACENT TO ONE ANOTHER ON PLANS WHEREVER PRACTICABLE. PROVIDE MULTI -GANG JUNCTION BOX AND COVER PLATE AS REQUIRED. 5. DASHED ARCS INDICATE CONTINUATION OF BRANCH CIRCUIT BUT NOT SWITCH CONTROL. 6. UNLESS OTHERWISE NOTED, ALL FIXTURES AND DEVICES SHOWN ON THIS PLAN ARE NEW. ALL NEW FIXTURES AND SWITCHES SHALL MATCH WELL 65 IN WINTERPARK. 7. VERIFY THAT DIMMER MATCHES LAMP TYPE PRIOR TO ORDER. & ELECTRICAL CONTRACTOR SHALL PROVIDE A LUMINAIRE DISCONNECT CONNECTOR FOR ALL FLUORESCENT FIXTURES, AS REQUIRED BY N.E.C, 410.130(g)3 2011. UL LISTED CONNECTORS ARE MANUFACTURER BY IDEAL, THOMAS AND BETTS AND WAGO, ANY UL LISTED CONNECTOR WILL BE ACCEPTABLE. INSTALL PER MANUFACTURERS SPECIFICATIONS. 9. EXISTING BRANCH CIRCUITS HAVE BEEN TAKEN FROM FIELD INVESTIGATION AND/OR ORIGINAL DOCUMENTS AND SHOWN FOR THE CONVENIENCE OF THE ELECTRICAL CONTRACTOR AND SHALL NOT BE CONSIDERED "AS -BUILT" CONDITION. BEFORE CONSTRUCTION BEGINS, ELECTRICAL CONTRACTOR SHALL FIELD VERIFY ALL BRANCH CIRCUITS. 10. CONTRACTOR SHALL INCLUDE COMMISSIONING OF LIGHTING CONTROL SYSTEM BY MANUFACTURER IN BASE BID, 11. VERIFY CEILING TYPES BEFORE ORDERING LIGHT FIXTURES. LIGHTING PLAN NOTES FEED FIXTURES FROM EXISTING, LOCAL LIGHTING CIRCUIT. FIELD VERIFY EXACT CIRCUIT NUMBER. TYPICAL ALL EXIT SIGNS. RUN AB 2#12 1 #12 GND - 3/4" C. PROVIDE A NEW EXTERIOR GRADE BUILDING WALL MOUNTED LED LIGHT FIXTURE (ANPLIGHTING TYPE ORB220-FR-MOl 6LDD-W-35K-RTCW) COORDINATE MOUNTING SOURCE, CORD STYLE AND FINISHES WITH ARCHiTECT/OWNER PRIOR TO ORDERING. CONNECT ALL BUILDING MOUNTED LIGHTS TO PANEL VIA TIME CLOCK WITH PHOTOCELL. REFER TO EXTERIOR LIGHTING/SIGNAGE WIRING DIAGRAM. "N ROVIDER WORK ROOM F-132--1 - ---� Do � _J —OF ONE -- row q < V 1-21541, V 1-19 1 7 BI- 5 WELLNESS SUITE 5 WELLN�SS SUITE WELLNESS SUITE I Ili's WELLNESS SUIT 8 1 6 F 7 I L -------- I?% f I OL 9 .02F HUDDLE Al-31 E;= I W limmmoppo-P 51111 L, i pffa 924 1, 1. d i wd .......... ............................ .. a El I AUTOCLAVE Al-18 Ik Wo Ali-16 .0111-111�.Al &A =A INC� --_� 2 POWER RENOVATION PLAN E3.1) 1/8" = V-0" GENERAL POWER NOTES 1 . INDICATED CIRCUIT NUMBERS ARE SUGGESTED FROM EXISTING SPARE BREAKERS AND SPACES IN EXISTING PANELS. CONTRACTOR MAY USE DIFFERENT CIRCUIT NUMBERS TO MATCH FIELD CONDITIONS. 2. ELECTRICAL CONTRACTOR SHALL COORDINATE WITH INTERIOR DESIGN PACKAGE FOR ALL MILLWORK AND WALL DESIGNS PRIOR TO COMMENCING WORK. 3. EXISTING BRANCH CIRCUITS HAVE BEEN TAKEN FROM FIELD INVESTIGATION AND /OR ORIGINAL DOCUMENTS AND SHOWN FOR THE CONVENIENCE OF THE ELECTRICAL CONTRACTOR AND SHALL NOT BE CONSIDERED "AS -BUILT" CONDITION. BEFORE CONSTRUCTION BEGINS, ELECTRICAL CONTRACTOR SHALL FIELD VERIFY ALL BRANCH CIRCUITS. 4. PROVIDE TYPED, UPDATED PANEL SCHEDULES UPON COMPLETION OF WORK. 5. PROVDE SHOW WINDOW RECEPTACLES ABOVE ALL WINDOWS PER CODE LISTED IN THIS NOTE: • Definition per Article 100 of NEC for Show Window - Any window, including windows above doors, used or designed to be used for the display of goods or advertising material, whether it is fully or partly enclosed or entirely open at the rear and whether or not it has a platform raised higher than the street floor level. • Article 210.62 of NEC Show Windows - provide at least (1) receptacle within 18in of top of show window for each 12 feet or major faction thereof (6' or more) of show window measured horizontally. • Article 210.14(G) and 220.43(A) regarding load calculations - 210.14(G) allows calculations for unit load per receptacle (180VA). We will use this method. 220.43(A) is for show window linear lighting which does not apply. 6. REFER TO FIRE ALARM NOTES, RISER AND SPKIFICATIONS FOR MORE INFORMATION. nr: �q" Of OUTLET BOX CONFIGURATION 13' LCD WDAX LOCATION POWER PLAN NOTES 0 CONNECT ELECTRIC WATER HEATER. PROVIDE 30A, 3P, 240V, CONNECT 120V POWER TO NEW EXHAUST FAN. PROVIDE N-1, NON -FUSED DISCONNECT SWITCH. COORDINATE WITH MOTOR -RATED SWITCH. COORDINATE WITH MECHANICAL PLUMBING CONTRACTOR. RUN 3#10, 1 #10 GND - 3/4" C. CONTRACTOR. FAN HAS MOTION SENSOR CONTROL. PROVIDE FLUSH MOUNTED FLOOR BOX WITH 120V QUAD CONNECT SPLIT SYSTEM. PROVIDE 30A, 2P, 240V, N-3R FUSED RECEPTACLE AND TELE/DATA OUTLETS, WALKER OMNIBOX DISCONNECT SWITCH ON ROOF, FUSE PER MANUFACTURER'S SERIES (#88OS2-TWO GANG) OR APPROVED EQUAL. SAWCUT NAMEPLATE. COORDINATE WITH MECHANICAL CONTRACTOR. FLOOR AS REQUIRED. RUN 2#12, 1 #12 FOR 120V POWER. ELECTRICAL POWER IS THROUGH CONDENSING UNIT THEN TO RUN 1-1/4" CONDUIT WITH PULLSTRING FOR LOW VOLTAGE INDOOR UNIT. CABLING. PROVIDE ALL ACCESSORIES REQUIRED FOR A RUN 2 #10 - 1 #10 GND - 3/4"C TO CONDENSING UNIT AND 2 COMPLETE SYSTEM. COORDINATE EXACT LOCATION, FINISHES, #10 - 1 #10 GND - 3/4"C TO INDOOR UNIT. COVERPLATES AND TYPE OF LOW VOLTAGE OUTLETS WITH PROVIDE 30A, 2P, 240V, N-1, FUSED DISCONNECT SWITCH AT OWNER. INDOOR UNIT, FUSE AS MANUFACTURER'S NAMEPLATE. (D NEW CARD READER AND ELECTRIC STRIKE. PROVIDE 3/4" (D EXTEND CONDUIT (2)4"C. TO NEW COMM ROOM. RACEWAY TO ACCESSIBLE CEILING FOR LOW VOLTAGE POWER. COORDINATE WITH CARD READER VENDOR. TENANT SECURITY PROVIDE RECESSED, FLANGELESS BOX WITH DUPLEX SYSTEM SHALL BE CONNECTED TO BUILDING FIRE ALARM RECEPTACLE AT HEIGHT SHOWN DRAWING 2/E3.1. ARLINGTON SYSTEM TO RELEASE ALL LOCKS UPON ACTIVATION. PROVIDE MODEL #TVBS81 0. ALL CONNECTIONS AND ACCESSORIES REQUIRED FOR A FULLY OPERATIONAL SYSTEM. ANY CARD READERS INSTALLED IN CONNECT 120V POWER TO NEW EXHAUST FAN. PROVIDE SUCH A WAY THAT THEY PREVENT FREE EGRESS SHALL BE IN MOTOR -RATED SWITCH. COORDINATE WITH MECHANICAL COMPLIANCE WITH SECTION 7.2.1.6.2 FOR ACCESS CONTRACTOR. FAN SHALL RUN CONTINUOUSLY. CONTROLLED EGRESS DOOR ASSEMBLIES (NFPA 101) PROVIDE 36" PROPER CLEARANCE PER NEC IN FRONT OF NEW PROVIDE RECESSED 2-GANG BOX AT 42" A.F.F FOR AV PANELS. CABLING. TYPICAL FOR ALL ALL WELLNESS SUITES. ARLINGTON MODEL #TVBS81 0, PROVIDE NEW FLOW AND TAMPER SWITCHES ON EXISTING BACKFLOW PREVENTER. CONNECT PER MANUFATURERS PROVIDE JUNCTION BOXES AND 120V CIRCUIT FOR DOOR SPECIFICATIONS. OPENER. COORDINATE EXACT REQUIREMENTS WITH VENDOR. REFER TO ARCHITECT'S DRAWING 2/AO.5 FOR RECESSED PROVIDE 8'H X 4W X 3/4"D PLYWOOD BACK BOARD ON WALL DRYWALL NICHE. LOCATE DUPLEX RECEPTACLE IN SIDE WALL OF (D FOR TELECOMMUNICATION EQUIPMENT. PAINT WITH GRAY FIRE NICHE AS SHOWN. RETARDENT PAINT. INSTALL DOUBLE DUPLEX RECEPTACLE MOUNTED @ 42" AFF. RUN 2" E.C. TO EXISTING MAIN TELEPHONE TERMINAL BOARD. PROVIDE #6 GROUND WITH BUS BAR CONNECTED TO BUILDING GROUND LUG. PA'nENT CARE AREA SYMBOL LEGEND <0> GENERAL CARE - CATEGORY 2 NOTES: 1. THERE ARE NO CRITICAL OR WET PATIENT AREAS IN THE SCOPE OF WORK. 2, GENERAL PATIENT CARE AREAS REQUIRE A WIRING METHOD WITH A REDUNDANT GROUND AS PER ARTICLE 517.13 OF THE NEC. GROUNDING 0 FALL RECEPTACLES, LIGHTING AND FIXED EQUIPMENT IN PATIENT CARE AREAS SHALL COMPLY WITH NEC ARTICLE 517.13 (A) AND (B) Al www.CVDstudio.com CAMPBELL + VAN DUSEN Design Studio, LLC. 255 South Orange Avenue Suite # 1240 Orlando, Florida 32801 Phone: 407.930.6016 FL. Lic. No. AA26003339 ARCHITECT OF RECORD FRANK W. CAMPBELL AIA FLLIC NO. AR0016053 COPY OF THIS PLAN IS NOT VALID UNLESS SIGNED, SEALED AND DATED BY THE ARCHITECT OF RECORD G. S PA 4,, r E N 4Z- % No. 6460' 3 -a STATE OF ell Bryan G. Spangler, PE, FL Reg. No. 64601 COPY OF THIS PLAN IS NOT VALID UNLESS SIGNED, SEALED AND DATED BY THE ENGINEER OF RECORD I LJ_ V� ry 0 F— q LU F— U I < Q 00 U_1 LU > I 0 = F_ F— + LO U = Cie < LU LLJ 0 -0 ,1- �10 U-) CL_ U-1 n-I < 3: or-01 CL ru-_41 CI*Yl)l CONSTRUCTION DOCUMENTS 03.24.2023 PRINCIPAL IN CHARGE F, CAMPBELL .................................................................... PROJECT MANAGER M. TORRES ................................................... ...... ......... ADVENT HEALTH WELL 65+ ZEPHYRHILLS 22-0328-01 ELECTRICAL RENOVATION PLANS NOTE: CONFIGURATION'A REFERS TO KEYED NOTE CONFIGURATION 'B' REFERS TO KEYED NOTE (D 11�flll III �i. � I _Tli I lif - I E3. I SANITARY WASTE RENOVATION PLAN P2. 1) 1/411 = 1 1-011 /—OA - - —OD OE OF GENERAL NOTES: 1. CONTRACTOR SHALL VISIT THE SITE PRIOR TO BIDDING AND CONSTRUCTION TO SURVEY EXISTING CONDITIONS. 2. CONTRACTOR SHALL INSTALL APPLIANCES PER MANUFACTURER'S PLUMBING REQUIREMENTS. KEY NOTES: (D CONTRACTOR SHALL TiE NEW 3' SANITARY WASTE LINE INTO //B\ NEAREST EXISTING SANITARY LINE OF ADEQUATE SIZE. CONTRACTOR SHALL COORDINATE CENTERING THE WALL CLEANOUT IN THE SPACE WERE THE ROLL —OUT CABINETRY RESIDES. REFER TO ARCHITECTURAL PLANS FOR CABINETRY DETAILS. EXISTING STORM DRAIN AND OVERFLOW PIPING. CONTRACTOR SHAH COORDINATE ALL DISCIPLINES. FIXTURES PIPE SIZE FIXTURE SAN SIZE VENT SIZE WATER CLOSET 3" 2" LAV / SINK 3* 1-1/2" WATER COOLER 3' 1-1/2- -ELECT FLOOR DRAIN 3m 2" NOTE: PLUMBING CONTRACTOR SHALL FIELD VERIFY, USING SUCH METHODS AS A SEWER CAMERA, LOW FREQUENCY GPR (GROUND PENETRATING RADAR) OR EM (ELECTROMAGNETIC) UTILITY LOCATING METHODS DURING DEMOLITION PHASE OF PROJECT TO DETERMINE THE EXACT CONDITION OF PIPE, LOCATION, SIZE, INVERT AND DIRECTION OF FLOW OF ALL EXISTING SANITARY/GREASE WASTE LINES WITHIN SCOPE OF PROJECT. DISCREPANCIES AND UNFORESEEN CONDITIONS ARE TO BE BROUGHT TO THE ATTEN11ON OF THE OWNER, ARCHITECT AND PROJECT ENGINEER PRIOR TO PROCEEDING WITH DEMOLITION IN THE AREA OF CONCERN. www.CVDstudio.com CAMPBELL + VAN DUSEN Design Studio, LLC, 255 South Orange Avenue Suite # 1240 Orlando, Florida 32801 Phone: 407.930.6016 FL. Lic. No. AA26003339 ARCHITECT OF RECORD FRANK W. CAMPBELL AIA FL LIC NO. AR001 6053 COPY OF THIS PLAN IS NOT VALID UNLESS SIGNED, SEALED AND DATED BY THE ARCHITECT OF RECORD \0\1111 I////// NN \pkmSS4 & . ............. cews \kp S-T P'-f E OF .......... ............ . N Ili; SfONA\� Taylor J. Lewis, PE, FL Reg. No. 90018 COPY OF THIS PLAN IS NOT VALID UNLESS SIGNED, SEALED AND DATED BY THE ENGINEER OF RECORD I Lj_ ry 0 LU r,v F— P-4 U I < (/) U_j L.LJ > _j F— F— + Lr-) U-17 __1.0 r1o" LU LL] 0 >'IT C) Lu '0 L(.) 0!:� < 3: or-2 0- rL�L_l (1y"') CONSTRUCTION DOCUMENTS 03.24.2023 DESCRIPTION PRINCIPAL IN CHARGE F. CAMPBELL ­­ ... I .... I ................................................ PROJECT MANAGER M. TORRES ............ I � ...... I ........ I ............ I ........ ­ .............. ADVENT HEALTH WELL 65+ ZEPHYRHILLS 22-0328-01 SANITARY WASTE RENOVATION __ - __ - ____ T7__F_ T _'__ 7­ -T __F_ I I �. I, . 1—, 11, � i I I , i - 7�7 � I- _]I --I T_T___.1 111 jj , hA i, I j I I I I I - ------ I- -H I F_ - __ - __ ___T_ , F (1,0 9 T- � n rin --- H --H I I I Lu Lj L U DOMESTIC WATER RENOVATION PLAN 1/4" = V-0. r-OA -- Do [CE OF --\-6G GENERAL NOTES: 1. CONTRACTOR SHALL VISIT THE SITE PRIOR TO BIDDING AND CONSTRUCTION TO SURVEY EXISTING CONDITIONS. 2. CONTRACTOR SHAH INSTALL RECIR. PUMP IN A EASY ACCESSIBLE LOCATION. 3. CONTRACTOR SHALL INSTALL VALVES FOR PIPING IN EASY ACCESSIBLE LOCATIONS AND WITHIN A CERTAIN DISTANCE TO MEET CODE. IF AN ACCESS DOOR IS NEEDED ONE SHALL BE INSTALLED. 4. CONTRACTOR SHALL INSTALL APPLIANCES PER MANUFACTURER'S PLUMBING REQUIREMENTS. KEY NOTES: CONTRACTOR SHALL PROVIDE 1/2" COLD WATER LINE WITH LEAD FREE DUAL CHECK BACKFI-OW PREVENTER TO NEW ICE MACHINE/ICE MAKER. BACKFLOW PREVENTER SHALL BE WATTS LF007 OR APPROVED EQUAL. CONTRACTOR SHALL PROVIDE LEAK/FLOOD DETECTION PROTEC11ON WITH "FLOODSTOP" DEVICE. COORDINATE NTH BUILDING OWNER ON SPECIFIC LOCA11ONS AND MODEL NUMBERS PER PLUMBING RENOVATION/INSTALLATION. CONTRACTOR SHALL INSTALL AND CONNECT NEW ELECTRIC WATER HEATER (EWH-1). SEE SHEET P1.1 FOR MORE INFORMATION. CONTRACTOR SHALL INSTALL NEW RECIRCULATINGPUMP. SEE ELECTRIC WATER HEATER DETAIL FOR MORE INFORMATION ON SHEET P1.1. �D CIRCUIT SOLVER THERMOSTATIC BALANCING VALVE WITH INTEGRATED UNION, LEAD FREE BALL VALVE AND CHECK VALVE INSERT. MODEL NO. CSUA-1/2-120—CV1-03 (OR APPROVED EQUAL). CONTRACTOR SHALL TIE NEW 2- COLD WATER LINE INTO NEAREST EXISTING 2" COLD WATER LINE. CONTRACTOR SHALL PROVIDE 112n COLD WATER LINE WITH LEAD FREE DUAL CHECK BACKFLOW PREVENTER TO NEW COFFEE MACHINE/COFFEE MAKER. BACKFLOW PREVENTER SHALL BE WATTS SD-3 OR APPROVED EQUAL COORDINATE FINAL LOCA11ON NTH ARCHITECT. FIXTURES' SUPPLY PIPE SIZE FIXTURE CW HW HWR WATER CLOSET 1/2" ELECT WATER COOLER 1/2" -- LAV / SINK 112n 1/2" 1/21f MOP SINK T 1/y 1/2', 1 -- WWI 9,111111112111 www.CVDstudio.com CAMPBELL + VAN DUSEN Design Studio, LLC. 255 South Orange Avenue Suite # 1240 Orlando, Florida 32801 Phone: 407.930.6016 FL. Lic. No. AA26003339 ARCHITECT OF RECORD FRANK W. CAMPBELL AIA FL LIC NO. AR001 6053 A\ COPY OF THIS PLAN IS NOT VALID UNLESS SIGNED, SEALED AND DATED BY THE ARCHITECT OF RECORD ....................... No. goo 18 S7-ATE OF 40 N V117; 0jVA L \N , i�-� 3-31-;L,� Tb�or J. Lewis, PE, FL Reg. No. 90018 COPY OF THIS PLAN IS NOT VALID UNLESS SIGNED, SEALED AND DATED BY THE ENGINEER OF RECORD __j U- V5 ry 0 LU U < ci C.") LU > I co + U LU )>�10 LU 0 LjLj 114- Lr) or-?, ru--4j (12) CONSTRUCTION DOCUMENTS 03.24.2023 PRINCIPAL IN CHARGE F. CAMPBELL ................... I ................... I ............... ...... PROJECT MANAGER M. TORRES .......................................... I .............. .......... ADVENT HEALTH WELL 65+ ZEPHYRHILLS 22-0328-01 DOMESTIC WATER RENOVATION P2.2 VV P�o 55 50ITi5 VVO"�00� 10 3 5AN .^A AN SAN //B\ I -�' V, " " ' *' " N �' " " " " " " �' '� '� '� '� '� �' " j00W'4%00W"'%t4h, N SANITARY WASTE RISER DIAGRAM N T3 4- WASIt I-INZ pco GENERAL NOTES: 1. CONTRACTOR SHALL VISIT THE SITE PRIOR TO BIDDING AND CONSTRUCTION TO SURVEY EXISTING CONDITIONS. 2. CONTRACTOR SHALL INSTALL APPLIANCES PER MANUFACTURER'S PLUMBING REQUIREMENTS. 3. CONTRACTOR SHALL COORDINATE THE SANITARY VENTING NTH THE EXISTING VTR'S ((1) 3- & (1) 2-) PROVIDED IN THE SHELL PACKAGE. IF THE EXISTING VTR'S ARE WITHIN 10'-0" OF THE RTU OUTSIDE AIR INTAKES THE CONTRACTOR SHALL COORDINATE NEW LOCATIONS. KEY NOTES: CONTRACTOR SHALL TIE NEW 3- SANITARY WASTE LINE INTO NEAREST EXISTING SANITARY LINE OF ADEQUATE SIZE. zk PROVIDE 3" VENT THRU ROOF. CONTRACTOR SHALL COORDINATE EXACT LOCATION NTH ROOFTOP AIR HANDLING UNITS TO MAINTAIN A MINIMUM OF 10'-0" CLEARANCE BETWEEN THE VENT AND THE ROOFTOP UNIT'S OUTSIDE AIR INTAKE. FIXTURES PIPE SIZE FIXTURE SAN SIZE VENT SIZE WATER CLOSET 3" 2" LAV / SINK 3" 1-1/2' ELECT WATER COOLER 30 1-1/2- FLOOR DRAIN 3- 2- NOTE: PLUMBING CONTRACTOR SHALL FIELD VERIFY, USING SUCH METHODS AS A SEWER CAMERA, LOW FREQUENCY GPR (GROUND PENETRATING RADAR) OR EM (ELECTROMAGNETIC) UTILITY LOCATING METHODS DURING DEMOLITION PHASE OF PROJECT TO DETERMINE THE EXACT CONDITION OF PIPE, LOCATION, SIZE, INVERT AND DIRECTION OF FLOW OF ALL EXISTING SANITARY/GREASE WASTE LINES WITHIN SCOPE OF PROJECT. DISCREPANCIES AND UNFORESEEN CONDITIONS ARE TO BE BROUGHT TO THE ATTENTION OF THE OWNER, ARCHITECT AND PROJECT ENGINEER PRIOR TO PROCEEDING WITH DEMOL111ON IN THEAREA OFCONCERN. CAMPBELL + VAN DUSEN ARCHITECTURE INTERIOR DESIGN www.CVDstudio.com CAMPBELL + VAN DUSEN Design Studio, LLC. 255 South Orange Avenue Suite # 1240 Orlando, Florida 32801 Phone: 407.930.6016 FL. Lic. No. AA26003339 ARCHITECT OF RECORD FRANK W. CAMPBELL AIA I'LLIC NO. AR0016053 COPY OF THIS PLAN IS NOT VALID UNLESS SIGNED, SEALED AND DATED BY THE ARCHITECT OF RECORD N �p Z! No. 'goo 18 -A STATE OF 0, ////�9 ON A L Tay1or J. Lewis, PE, FL Reg. No. 90018 COPY OF THIS PLAN IS NOT VALID UNLESS SIGNED, SEALED AND DATED BY THE ENGINEER OF RECORD I LL- ry 0 F— CL ri LU ry r,4 U < L") LU LU > I CID + LO U = -'0 Lij Ljj 0 > 110 f:� LU 10 LJO OL < 3�: rL-U4 00 CO r-4., Cy") CONSTRUCTION DOCUMENTS 03.24.2023 NO. DATE DESCRIPTION 5/03/2023 DDENDUM B 7/28/2023 E LTA 1 2 25/2023 IREVISION 2 PRINCIPAL IN CHARGE F. CAMPBELL ...................... ....................................... PROJECT MANAGER M. TORRES ............... I .................................................... ADVENT HEALTH WELL 65+ ZEPHYRHILLS 22-0328-01 MEP CONSULTING SANITARY WASTE ENGINEERS SINCE 1977 RISER DIAGRAM FL REG NO. 3089 2016 ALDEN RD. ORLANDO, FL. 32603 (407) 246-1688 WWPOFLA.COM P3. 1 PEI PROECT 22121