Loading...
HomeMy WebLinkAbout7866 Gall Blvd (2)k 4 August 3, 2023 City of Zephyrhills 5335 &' Street Zephyrhills, Florida 33542 Re: AdventHealth Well 65+ - Zephyrhills PEI Job #22121 To Whom it May Concern, The following letter contains changes made to the above -referenced project: Mechanical Sheet Ml.l Revised diffuser/grille locations per shifts in Architectural Reflected Ceiling Plan. Relocated ductless split indoor unit per shifts in Architectural Floor Plan. Sheet E1.1 Revised drawing to add fire alarm specifications. Sheet E2.1 Revised drawing to reflect actual electrical service layout per updated shell plans. Sheet E31 Revised location of light fixtures per updated reflected ceiling plan from Architect. Revised location of receptacles per updated Architectural Plan. Added fire alarm devices throughout suite. Sheet E3.2 Revised drawing to show fire alarm devices for HVAC units on roof Revised notes accordingly. Sheet E4.1 Revised Panel Schedules. Sheet E5.1 Revised drawing to reflect actual electrical service riser per updated shell plans. Added fire alarm riser diagram. Sheet E5.2 Revised Light Fixture Schedule. EXCELLENCE IN ENGINEERING SINCE 1977 2016 ALDEN ROAD ■ ORLANDO, FLORIDA 32803 ■ VOICE 407.246.1688 ■ FAX 407.246.1664 ■ www.peifla.com 4W BUILDING INFORMATION APPLICABLE CODES ALL CONSTRUCTION SPECIFIED ON THESE DOCUMENTS SUBMITTED FOR BUILDING PERMIT SHALL COMPLY WITH ALL CODES AND ORDINANCES OF CITY OF ZEPHYRHILLS, FLORIDA. INCLUDING REVISIONS, AMENDMENTS AND APPENDICES TO THE FOLLOWING CODES: FLORIDA EXISTING BUILDING CODE 7TH EDITION (2020) FLOR�DA ACCESSIBLITY CODE 7TH EDITION (2020) FLOR DA MECHANICAL CODE 7TH EDITION (2020) FLORIDA PLUMBING CODE 7TH EDITION (2020) FLORIDA FIRE PREVENTION CODE 7TH EDITION (2020) FLORIDA ENERGY CONSERVATION CODE 7TH EDITION (2020) ADDITIONAL APPLICABLE CODES NFPA 101 LIFE SAFETY CODE FLORIDA EDITION NATIONAL ELECTRIC CODE 2017 EDITION FLORIDA EXISTING BUILDING CODE 7TH EDITION (2020) OCCUPANCY CLASSIFICATION FLORIDA BUILDING CODE, CHAPTER 3: SECTION 304: BUSINESS GROUP 8 BUSINESS GROUP B OCCUPANCY INCLUDES, AMONG OTHERS, THE USE OF A BUILDING OR STRUCTURE, OR A PORTION THEREOF, FOR OFFICE, PROFESSIONAL OR SERVICE -TYPE TRANSACTIONS, INCLUDING STORAGE OF RECORDS AND ACCOUNTS. CONSTRUCTION CLASSIFICATION FLOR�DA BUILDING CODE, CHAPTER 6: TYPE VB CONSTRUCTION - EXISTING CONSTRUCTION PERMITTED EXIST SHELL BUILDING INFO BUILDING HEIGHT: I STORY SPRINKLERED: YES -EXISTING UNDER SEPARATE PERMIT MEZZANINE: NO FIRE DISTRICT: NO INTERIOR FINISHES FLORIDA BUILDING CODE, CHAPTER 8: BUSINESS - GROUP B (SPRINKLERED) INTERIOR WALL AND CEILING FINISHES REQUIREMENTS - TABLE 803.5 EXIT ACCESS CORRIDORS / EXITWAYS: CLASS B ROOMS AND ENCLOSED SPACES: CLASS C BUILDING / UNIT INFORMATION TENANT S.F. COMMON AREA S.F. TOTAL FLOOR S.F. 1 ST FLOOR 6,706 S.F. N/A N/A ADDITIONAL PERMITS ANY APPLICABLE PERMITS OR APPROVAL REQUIRED BY ANY OTHER GOVERNMENT AGENCY (DEP, DOT, SWFWMD, COUNTY, ETC.) ARE THE RESPONSABILITY OF THE APPLICANT TO OBTAIN. 7L DD SCOPE OF WORK INTERIOR FIT -OUT OF AN EXISTING I -STORY SHELL BUILDING - 6,706 S.F. BUSINESS OCCUPANCY INCLUDING OFFICES, CONFERENCE ROOM AND BREAK ROOM. TENANT REQUIREMENTS EXIT REQUIREMENTS NUMBER AND ARRANGEMENT OF EXITS: REFERENCE DRAWING AO.6 FLOOR MIN NU BER TRAVEL DIS ANCE ARRANGEMENT OF EXITS I MEANS OF EGRESS REQUIRED SHOWN ALLOWABLIIHOWN REQUIRED SHOWN TBL.1021.1 ON PLAN TBL.1016.1 ON PLAN BETWEEN ON PLAN DOORS TENANT 300' 55'-9" CORRIDOR DEAD ENDS (SECTION 1017.3) COMMON PATH OF TRAVEL (SECTION 10 14.3) OCCUPANT LOAD AND EXIT WIDTH CALCULATED OCUPANT LOAD - EXISTING BUSINESS BUILDING = 6,706 SF BREAK ROOM: ASSEMBLY 394 SF / 15 NET = 27 PERSONS COMMUNITY: 394 SF / 15 NET = 27 PERSONS WAITING: 233 SF / 15 NET = 16 PERSONS COMM ROOM: 83 SF / 300 NET = I PERSON ELEC. ROOM/F. RISER: 74 SF 300 NET = 1 PERSON STORAGE 1: 36 SF / 300 NET 1 PERSON STORAGE 2:86 SF / 300 NET I PERSON BIO: 12 SF 300 NET I PERSON J.C.: 34 SF 300 NET I PERSON TOTAL OCCUPANCY = 112 PERSONS PLUMBING FIXTURE REQUIREMENTS I ST FLOOR MALE FEMALE BUSINESS REQUIRED PROVIDED REQUIRED PROVIDED 112 PERSONS TOILETS 2 4 2 4 LAVATORIES 2 4 2 4 SERVICE SINK I I DRINKING _T 1 1 FOU IN NTA NOTE: TOILETS EXISTING BUILDING PROVIDED NOT IN SCOPE OF WORK FIXTURES REQUIRED / (FIXTURES PROVIDED) LEGAL DESCRIPTION PARCEL ID#: 35-25-21-0130-00000-0040 ZEPHYR COMMONS PHASE 1 PB 65 PG 132 LOT 4 OR 9254 PG 1646 57 7 �qA C 0 1 o Po-sco COL."nlw Transfer S t Aa t ic" n; 0 1 d! S t, e rno,vatmni 11reo + r - r or r I Q Pasadena Hills iM7874 Gall Blvd, Rd Zephyrhills, FL 3354! ZERHYRHILLS COLONY C b kI PA N Y ID --,3 M e x'c o 1�0 a Iscosi r Zelphyrhills R e T B a r a n d G r I North 9 oft- %" U N h A� SITE LOCATION. C�_ ARCHITECTURE INTERIOR DESIGNER CAMPBELL + VAN DUSEN DESIGN STUDIO 255 SOUTH ORANGE AVENUE SUITE 1240 ORLANDO, FLORIDA 32801 407.930.6016 CONTACT: FRANK W. CAMPBELL CONTACT: GLORIA VAN DUSEN ELECTRICAL ENGINEER PENINSULA ENGINEERING, INC 2016 ALDEN ROAD ORLANDO, FLORIDA 32803 407.246.1688 CONTACT: BRYAN SPANGLER ADVENT HEALTH + WELL 65 ZEPHYRHILLS WITH PREVAILING ALL WORK SHALL COMPLY CODES FLORIDA BUILDING CODE, NATIONAL ELECTRIC CODE, AND THE CITY OF ZEPHYRHILLS ORDINANCES MECH & PLUMB ENGINEER PENINSULA ENGINEERING, INC. 2016 ALDEN ROAD ORLANDO, FLORIDA 32803 407.246.1688 CONTACT: BRYAN SPANGLER 7866 GALL BOULEVARD, ZEPHYRHILLS, FLORIDA 33541 qV DAT REVIE j �R_H I L S ZEPH OF G OFFICIAL BUILDIN BUILDING OWNERS ADVENTHEALTH 900 HOPE WAY ALTAMONTE SPRINGS, FLORIDA 32714 407.963.1014 CONTACT: DANIEL TOM F__ 0 El El L L L LA-7 4 ''_4 ,d JA -4. A' *'A- �'4 L oil 40 MINE AREA OF WORK, f CONTRACTOR TBID A 7 i ALL Wo&. 'N-�F� c ,( SHALL COMPLy W, O'DES AND S -rANI) I-rij ARDS FtLWWDATE .,A�l (M0FZEPHY4mILLS Fft MID LIFE SAFgTy gMWgR CAMPBELL +VAN DUSEN ARCHITECTURE INTERIOR DESIGN www.CVDstudio.com CAMPBELL + VAN DUSEN Design Sfudio, LLC. 255 Soufh Orange Avenue Suife #1240 Orlando, Florida 32801 Phone: 407.930.6016 FL. Lic. No. AR001 6053 A/ ARCHITECT OF RECORD FRANK W. CAMPBELL AIA FL LIC NO. AR001 6053 COPY OF THIS PLAN IS NOT VALID UNLESS SIGNED, SEALED AND DATED BY THE ARCHITECT OF RECORD + CD COPY OF THIS PLAN IS NOT VALID UNLESS SIGNED, SEALED AND DATED BY THE ENGINEER OF RECORD LL_ V� __j F— n b LLJ 0::� II___ U Lij LLJ n I + U -0 < LU LjLj (D 1�0 ,I- C) Lu CL- "o Lr) U_j 0c) cy) ISSUE FOR CONSTRUCTION DOCUMENTS ISSUE DATE 03.24.2023 REVISIONS PROJECT TEAM PFINCII'AL JN CHA�'G� F. CAMPBELL ...................... ...... PROJECT MANAGER M. TORRES ........... I ....... ......... .......... CLIENT NAME ADVENT HEALTH WELL 65+ ZEPHYRHILLS PROJECT NUMBER 22-0328-01 SHEET TITLE COVER SHEET A7_ SHEET NUMBER A0.0 32 min (a) Details 32 min (C) Sliding Door 32 min (d) Folding Door DOORS & MANEUVERING CLEARANCES 32MIN 815 (b) Hinged Door .E E 18 min. 24 prefe�ed 455 NOTE: x = 12 in (305 mm) if door has both a closer and latch. \Ij Front Approaches - Swinging Doors 54 min 32 min 815 x E ]E NOTE: x 36 in (915 mm) minimum if y 60 In NOTE: y 48in (1220 mm) minimum ifdoor has (e) (1525 mm): x = 42 in (1063 mm) minimum if y both a latch and closer� Mammum Doorway Depth 54 in (1370 mm) (b) Hinge Side Approaches - Swinging Doors Fig. 24 Clear Doorway Width and Depth x 24 min 610 24 min x 610 E E V NOTE: y 54 in (1370 mm) minimum if door has NOTE: y 48 in (1220 mm) minimum if door has closer. closer. (c) Latch Side Approaches - Swinging Dom 48 min 1220 'A min 1370 -c E E (d) Front Approach - Sliding Doors and Folding Doors (e) Slide Side Approach - -Sliding Doors and Folding Doors B Min 4 122D NOTE: All doors in alcoves x 24 min 610 shall comply with the clearances for front approaches E C� L— — — — — — — — — — — — — Latch Side Approach - Sliding Doors and Folding Doors Fig. 26 Fig. 25 Two Hinged Doors in Series Maneuveriing Clearances at Doors (Continued) 404 DOORS. DOORWAYS. AND GA ES 404.1 GENERAL, DOORS, DOORWAYS, AND GATES THAT ARE PART OF AN ACCESSIBLE ROUTE SHALL COMPLY WITH 404. 404.2.1 REVOLVING DOORS. GATES, AND TURNSTILES. REVOLVING DOORS, REVOLVING GATES, AND TURNSTILES SHALL NOT BE PART OF AN ACCESSIBLE ROUTE. 404.2.2 DOUBLE -LEAF DOORS AND GATES, AT LEAST ONE OF THE ACTIVE LEAVES OF DOORWAYS WITH TWO LEAVES SHALL COMPLY WITH 404.2.3 AND 404.2.4. 404.2.3 CLEAR WIDTH, DOOR OPENINGS SHALL PROVIDE A CLEAR WIDTH OF 32 INCHES (815 MM) MINIMUM. CLEAR OPENINGS OF DOORWAYS WITH SWINGING DOORS SHALL BE MEASURED BETWEEN THE FACE OF THE DOOR AND THE STOP, WITH THE DOOR OPEN 90 DEGREES. OPENINGS MORE THAN 24 INCHES (610 MM) DEEP SHALL PROVIDE A CLEAR OPENING OF 36 INCHES (915 MM) MINIMUM. THERE SHALL BE NO PROJECTIONS IN TO THE REQUIRED CLEAR OPENING WIDTH LOWER THAN 34 INCHES (865 MM) ABOVE THE FINISH FLOOR OR GROUND. PROJECTIONS INTO THE CLEAR OPENING WIDTH BETWEEN 34 INCHES (865 MM) AND 80 INCHES (2030 MM) ABOVE THE FINISH FLOOR OR GROUND SHALL NOT EXCEED 4 INCHES (100 MM). EXCEPTIONS: 1. IN ALTERATIONS, A PROJECTION OF 5/8 INCH (16 MM) MAXIMUM INTO THE REQUIRED CLEAR WIDTH SHALL BE PERMITTED FOR THE LATCH SIDE STOP. 2. DOOR CLOSERS AND DOOR STOPS SHALL BE PERMITTED TO BE 78 INCHES (1980 MM) MINIMUM ABOVE THE FINISH FLOOR OR GROUND. 404.2.4 MANEUVERING CLEARANCES, MINIMUM MANEUVERING CLEARANCES AT DOORS AND GATES SHALL COMPLY WITH 404.2.4. MANEUVERING CLEARANCES SHALL EXTEND THE FULL WIDTH OFTHE DOORWAY AND THE REQUIRED LATCH SIDE OR HINGE SIDE CLEARANCE. EXCEPTION: ENTRY DOORS TO HOSPITAL PATIENT ROOMS SHALL NOT BE REQUIRED TO PROVIDE THE CLEARANCE BEYOND THE LATCH SIDE OF THE DOOR. 404.2.4.1 SWINGING DOORS AND GATES, SWINGING DOORS AND GATES SHALL HAVE MANEUVERING CLEARANCES COMPLYING WITH TABLE 404.2.4. 1. 404.2.4.2 DOORWAYS WITHOUT DOORS OR GATES, SLIDING DOORS. AND FOLDING DOORS, DOORWAYS LESS THAN 36 INCHES (915 MM) WIDE WITHOUT DOORS OR GATES, SLIDING DOORS, OR FOLDING DOORS SHALL HAVE MANEUVERING CLEARANCES COMPLYING WITH TABLE 404.2.4.2. 404.2.4.3 RECESSED DOORS AND GATES, MANEUVERING CLEARANCES FOR FORWARD APPROACH SHALL BE PROVIDED WHEN ANY OBSTRUCTION WITHIN 18 INCHES (455 MM) OFTHE LATCH SIDE OF A DOORWAY PROJECTS MORETHAN 8 INCHES (205 MM) BEYOND THE FACE OF THE DOOR, MEASURED PERPENDICULAR TO THE FACE OF THE DOOR OR GATE. ADVISORY 404.2.4.3 RECESSED DOORS AND GATES. A DOOR CAN BE RECESSED DUE TO WALL THICKNESS OR BECAUSE OF THE PLACEMENT OF CASEWORK AND OTHER FIXED ELEMENTS ADJACENT TO THE DOORWAY. THIS PROVISION MUST BE APPLIED WHEREVER DOORS ARE RECESSED. 404.2.5 THRESHOLDS, THRESHOLDS, IF PROVIDED AT DOORWAYS, SHALL BE 1/2 INCH (13 MM) HIGH MAXIMUM. RAISED THRESHOLDS AND CHANGES IN LEVEL AT DOORWAYS SHALL COMPLY WITH 302 AND 303. EXCEPTION: EXISTING OR ALTERED THRESHOLDS 3/4 INCH (19 MM) HIGH MAXIMUM THAT HAVE A BEVELED EDGE ON EACH SIDE WITH A SLOPE NOT STEEPER THAN 1:2 SHALL NOT BE REQUIRED TO COMPLY WITH 404.2.5. 404.2.6 DOORS IN SERIES AND GATES IN SERIES, THE DISTANCE BETWEEN TWO HINGED OR PIVOTED DOORS IN SERIES AND GATES IN SERIES SHALL BE 48 INCHES (1220 MM) MINIMUM PLUS THE WIDTH OF DOORS OR GATES SWINGING INTO THE SPACE. 404.2.7 DOOR AND GATE HARDWARE, HANDLES, PULLS, LATCHES, LOCKS, AND OTHER OPERABLE PARTS ON DOORS AND GATES SHALL COMPLY WITH 309.4. OPERABLE PARTS OF SUCH HARDWARE SHALL BE 34 INCHES (865 MM) MINIMUM AND 48 INCHES (1220 MM) MAXIMUM ABOVE THE FINISH FLOOR OR GROUND. WHERE SLIDING DOORS ARE IN THE FULLY OPEN POSITION, OPERATING HARDWARE SHALL BE EXPOSED AND USABLE FROM BOTH SIDES. EXCEPTIONS: 1. EXISTING LOCKS SHALL BE PERMITTED IN ANY LOCATION AT EXISTING GLAZED DOORS WITHOUT STILES, EXISTING OVERHEAD ROLLING DOORS OR GRILLES, AND SIMILAR EXISTING DOORS OR GRILLES THAT ARE DESIGNED WITH LOCKS THAT ARE ACTIVATED ONLY AT THE TOP OR BOTTOM RAIL. 2. ACCESS GATES IN BARRIER WALLS AND FENCES PROTECTING POOLS, SPAS, AND HOT TUBS SHALL BE PERMITTED TO HAVE OPERABLE PARTS OF THE RELEASE OF LATCH ON SELF -LATCHING DEVICES AT 54 INCHES (1370 MM) MAXIMUM ABOVE THE FINISH FLOOR OR GROUND PROVIDED THE SELF -LATCHING DEVICES ARE NOT ALSO SELF-LOCKING DEVICES AND OPERATED BY MEANS OF A KEY, ELECTRONIC OPENER, OR INTEGRAL COMBINATION LOCK. ADVISORY 404.2.7. DOOR AND GATE HARDWARE. DOOR HARDWARE THAT CAN BE OPERATED WITH A CLOSED FIST OR A LOOSE GRIP ACCOMMODATES THE GREATEST RANGE OF USERS. HARDWARE THAT REQUIRES SIMULTANEOUS HAND AND FINGER MOVEMENTS REQUIRE GREATER DEXTERITY AND COORDINATION, AND IS NOT RECOMMENDED. 404.2.8 CLOSING SPEED, DOOR AND GATE CLOSING SPEED SHALL COMPLY WITH 404.2.8. 404.2.8.1 DOOR CLOSERS AND GATE CLOSERS, DOOR CLOSERS AND GATE CLOSERS SHALL BE ADJUSTED SO THAT FROM AN OPEN POSITION OF 90 DEGREES, THE TIME REQUIRED TO MOVE THE DOOR TO A POSITION OF 12 DEGREES FROM THE LATCH IS 5 SECONDS MINIMUM. 404.2.8.2 SPRING HINGES, DOOR AND GATE SPRING HINGES SHALL BE ADJUSTED SO THAT FROM THE OPEN POSITION OF 70 DEGREES, THE DOOR OR GATE SHALL MOVE TO THE CLOSED POSITION IN 1 .5 SECONDS MINIMUM. 404.2.9 DOOR AND GATE OPENING FORCE., FIRE DOORS SHALL HAVE A MINIMUM OPENING FORCE ALLOWABLE BY THE APPROPRIATE ADMINISTRATIVE AUTHORITY. THE FORCE FOR PUSHING OR PULLING OPEN A DOOR OR GATE OTHER THAN FIRE DOORS SHALL BE AS FOLLOWS: 1. INTERIOR HINGED DOORS AND GATES: 5 POUNDS (22.2 N) MAXIMUM. 2. SLIDING OR FOLDING DOORS: 5 POUNDS (22.2 N) MAXIMUM. 3. EXTERIOR HINGED DOORS SHALL BE DESIGNED SO THAT SUCH DOORS CAN BE PUSHED OR PULLED OPEN WITH A FORCE NOT EXCEEDING 8.5 POUNDS (37.8 N). THESE FORCES DO NOT APPLY TO THE FORCE REQUIRED TO RETRACT LATCH BOLTS OR DISENGAGE OTHER DEVICES THAT HOLD THE DOOR OR GATE IN A CLOSED POSITION. ADVISORY 404.2.9 DOOR AND GATE OPENING FORCE. THE MAXIMUM FORCE PERTAINS TO THE CONTINUOUS APPLICATION OF FORCE NECESSARY TO FULLY OPEN A DOOR, NOT THE INITIAL FORCE NEEDED TO OVERCOME THE INERTIA OF THE DOOR. IT DOES NOT APPLY TO THE FORCE REQUIRED TO RETRACT BOLTS OR TO DISENGAGE OTHER DEVICES USED TO KEEP THE DOOR IN A CLOSED POSITION. FLORIDA LAW, s.553.504(6),F.S., ESTABLISHES REQUIREMENTS FOR EXTERIOR DOOR OPENING FORCE. 404.2.8.2 SPRING HINGES. DOOR AND GATE SPRING HINGES SHALL BE ADJUSTED SO THAT FROM THE OPEN POSITION OF 70 DEGREES, THE DOOR OR GATE SHALL MOVE TO THE CLOSED POSITION IN 1 .5 SECONDS MINIMUM. 404.3 AUTOMATIC AND POWER -ASSISTED DOORS AND GATES, AUTOMATIC DOORS AND GATES SHALL COMPLY WITH 404.3. FULL -POWERED AUTOMATIC DOORS SHALL COMPLY WITH ANSI/BHMA A156.10 (INCORPORATED BY REFERENCE, SEE "REFERENCED STANDARDS" IN CHAPTER 1.) LOW -ENERGY AND POWER -ASSISTED DOORS SHALL COMPLY WITH ANSI/BHMA A 156.19 (1997 OR 2002 EDITION) (INCORPORATED BY REFERENCE, SEE "REFERENCED STANDARDS" IN CHAPTER I). 404.3.1 CLEAR WIDTH, DOORWAYS SHALL PROVIDE A CLEAR OPENING OF 32 INCHES (815 MM) MINIMUM IN POWER -ON AND POWER -OFF MODE.THE MINIMUM CLEAR WIDTH FOR AUTOMATIC DOOR SYSTEMS IN A DOORWAY SHALL BE BASED ON THE CLEAR OPENING PROVIDED BY ALL LEAVES IN THE OPEN POSITION. 404.3.2 MANEUVERING CLEARANCE, CLEARANCES AT POWER -ASSISTED DOORS AND GATES SHALL COMPLY WITH 404.2.4. CLEARANCES AT AUTOMATIC DOORS AND GATES WITHOUT STANDBY POWER AND SERVING AN ACCESSIBLE MEANS OF EGRESS SHALL COMPLY WITH 404.2.4. EXCEPTION: WHERE AUTOMATIC DOORS AND GATES REMAIN OPEN IN THE POWER -OFF CONDITION, COMPLIANCE WITH 404.2.4 SHALL NOT BE REQUIRED. 404.3.5 CONTROLS, MANUALLY OPERATED CONTROLS SHALL COMPLY WITH 309. THE CLEAR FLOOR SPACE ADJACENT TO THE CONTROL SHALL BE LOCATED BEYOND THE ARC OF THE DOOR SWING. CAMPBELL +VAN DUSEN ARCH ITECTU RE INTERIOR DESIGN www.CVDstudio.com CAMPBELL + VAN DUSEN Design Studio, LLC. 255 South Orange Avenue Suite # 1240 Orlando, Florida 32801 Phone: 407.930.6016 FL. Lic. No. AROO 16053 ARCHITECT OF RECORD FRANK W. CAMPBELL AIA FLLIC NO. AR0016053 COPY OF THIS PLAN IS NOT VALID UNLESS SIGNED, SEALED AND DATED BY THE ARCHITECT OF RECORD COPY OF THIS PLAN IS NOT VALID UNLESS SIGNED, SEALED AND DATED BY THE ENGINEER OF RECORD _j LL_ ry 0 F_ CL CL LU u < r) U0 > Uj Lij _j F— F— + L0 Q = 14C) < U-J LU > I I 0 0 LU NO It -,,o L6 0!:� CL LU r-4 00 (V) r-, (y) CONSTRUCTION DOCUMENTS 03.24.2023 DESCRIPTION PRINCIPAL IN CHARGE F. CAMPBELL ............................................................... .... PROJECTMANAGER M. TORRES ............................................................... .... ADVENT HEALTH WELL 65+ ZEPHYRHILLS 22-0328-01 NOTES A0e1 CONTRACTOR NOTES: 1 . SABBATH EXCLUSION: NO WORK SHALL BE UNDERTAKEN DURING THE SABBATH (FRIDAY AT SUNSET THRU SATURDAY). 2. OVERTIME: WORK PERFORMED DURING OVERTIME HOURS NOT INCLUDED IN THE CONTRACT FOR CONSTRUCTION SHALL BE APPROVED IN ADVANCE VIA CHANGE ORDER. 3. ALL WORK SHALL BE DONE IN A SAFE WORKMANLIKE MANNER AND IN STRICT ACCORDANCE WITH THE LOCAL AND/ OR STATE (IF APPLICABLE) BUILDING CODES. NATIONAL ELECTRIC CODE (NEC), ADA-ADAAGS (ADOPTED HANDICAPP ACCESSIBILTY REQUIRMENTS), OSHA AND ALL APPLICABLE CODES, REGULATIONS, ORDINANCES AND AUTHORITITES HAVEING JURISDICTION. 4. TO THE EXTENT REQUIRED BY LAW ALL WORK SHALL BE PERFORMED BY INDIVIDUALS DULY LICENSED AND AUTHORIZED BY LAW TO PERFORM SAID WORK. 5. CONTRACTOR MAY AT ITS DISCRETION ENGAGE SUBCONTRACTORS TO PERFORM WORK HEREUNDER, PROVIDED CONTRACTOR SHALL FULLY PAY SAID SUBCONTRACTOR AND IN ALL INSTANCES REMAIN RESPONSIBLE FOR THE PROPER COMPLETION OF THIS CONTRACT. 6. EACH SUBCONTRACTOR IS RESPONSIBLE FOR HAVING A THROUGH KNOWLEDGE OF ALL DRAWINGS AND SPECIFICATIONS IN THEIR RELATED FIELD. THE FAILURE TO ACQUAINT THEMSELVES WITH THIS KNOWLEDGE DOES NOT RELIEVE THEM OF ANY RESPONSIBLITY FOR PERFORMING THEIR WORK PROPERLY. NO ADDITIONAL COMPENSATION SHALL BE ALLOWED BECASUE OF CONDITIONS THAT OCCUR DUE TO FAILURE TO FAMILIARIZE WORKERS WITH THIS KNOWLEDGE. 7. THE CONTRACTOR SHALL MAINTAIN THE INTEGRITY OF THE EXISTING BUILDING SECURITY AT ALL TIMES. THIS INCLUDES KEEPING THE BUILDING SECURE FROM PERSONS, ENVIRONMENTAL ELEMENTS OR HAZARDS. THE CONTRACTOR SHALL BE RESPONSIBLE TO MAINTAIN THE INTEGRITY OF ALL EXISTING SECURITY SYSTEMS. 8. CONTRACTOR SHALL FURNISH OWNER APPROPRIATE RELEASES OR WAIVERS OF LIEN FOR ALL WORK PERFORMED OR MATERIALS PROVIDED AT THE TIME THE NEXT PERIODIC PAYMENT SHALL BE DUE. 9. CONTRACTOR SHALL PROVIDE ALL CHANGE ORDERS IN WRITING. CHANGE ORDER SHALL DESCRIBE ALL COST, TIME AND INCLUDE A DESCRIPTION OF THE WORK. NO WORK SHALL COMMENCE WITHOUT CHANGE ORDER BEING SIGNED AND APPROVED BY BOTH OWNER AND ARCHITECT. 10. CONTRACTOR WARRANTS IT IS ADEQUATELY INSURED FOR INJURY TO ITS EMPLOYEES AND OTHERS INCURRING LOSS OR INJURY AS A RESULT OF THE ACTS OF CONTRACTOR OR ITS EMPLOYEES AND SUBCONTRACTORS. 11. CONTRACTOR SHALL AT ITS OWN EXPENSE OBTAIN ALL PERMITS NECESSARY FOR THE WORK TO BE PERFORMED. 12. CONTRACTOR AGREES TO REMOVE ALL DEBRIS AND LEAVE THE PREMISES IN BROOM CLEAN CONDITION. 13. IN THE EVENT OWNER SHALL FAIL TO PAY ANY PERIODIC OR INSTALLMENT PAYMENT DUE HEREUNDER, CONTRACTOR MAY CEASE WORK WITHOUT BREACH PENDING PAYMENT OR RESOLUTION OF ANY DISPUTE. 14. CONTRACTOR SHALL NOT BE LIABLE FOR ANY DELAY DUE TO CIRCUMSTANCES BEYOND ITS CONTROL INCLUDING STRIKES, CASUALTY OR GENERAL UNAVAILABILITY OF MATERIALS. 15. THE CONTRACTOR SHALL COMPLY WITH ALL APPLICABLE OSHA RULES AND REGULATIONS. 16. ALL CONSTRUCTION CONDITIONS TO BE VERIFIED IN THE FIELD, ANY DISCREPANCIES, OMISSIONS AND ERRORS DISCOVERED BY THE CONTRACTOR SHALL BE BROUGHT TO THE ARCHITECT'S ATTENTION AT ONCE. THIS INCLUDES EXISTING AND NEW CONDITIONS AND DIMENSIONS. THE CONTRACTOR IS NOT TO PROCEED WITH OUT CONTACTING THE ARCHITECT, 17. THE CONTRACT DOCUMENTS ARE A GRAPHIC REPRESENTATION OF THE CONDITIONS AND THE WORK TO BE DONE. THESE DOCUMENTS SHOULD NOT BE SCALED. THE WRITTEN DIMENSIONS SHALL TAKE PRECEDENT OVER ANY AND ALL SCALED DIMENSIONS. THE MANUFACTURERS SPECIFICATIONS SUPERSEDE THE CONTRACT DOCUMENTS AS APPLICABLE. 18. ANY DEVIATION FROM THE CONTRACT DOCUMENTS MUST BE APPROVED BY THE ARCHITECT PRIOR TO CONSTRUCTION. ANY CHANGES THAT ARE NOT APPROVED SHALL BECOME THE RESPONSIBILITY OF THE CONTRACTOR 19. ALL MATERIALS, SYSTEMS, AND COMPONENTS SHALL BE AS SPECIFIED AND INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS AND SPECIFICATIONS. THE CONTRACTOR COORDINATES THE WORK OF ALL TRADES, IN ORDER TO ASSURE PROPER COORDINATION. 20. THE CONTRACTOR IS RESPONSIBLE FOR THE STORAGE AND SECURITY OF ALL BUILDING MATERIALS. THEY SHALL KEEP THE PREMISES AND WORK AREA IN A REASONABLY NEAT AND ORDERLY CONDITION. THE CLEANING OF THE AREAS ON A TIMELY BASIS IS NOT TO INTERFERE WITH ANY CONSTRUCTION CURRENTLY UNDER WAY. 21. THE CONTRACTOR SHALL KEEP WORK AREA CLEAN AND FREE OF DEBRIS AND is TO REMOVE ALL TRASH AND DEBRIS FROM THE CONSTRUCTION AREA DAILY. NO FLAMMABLE MATERIALS OR LIQUIDS MAY BE STORED IN THE EXISTING BUILDING OR ANY NEW ADDITION. 22. REMOVE ANY EXISTING ITEMS, SERVICES, FINISHES OR SURFACES AS REQUIRED FOR THE INSTALLATION OF NEW CONSTRUCTION. PROVIDE FURRING FOR CONDUITS AND PIPING, SHOWN OR NOT, AND FINISH OUT FURRING TO MATCH ADJACENT EXISTING FINISHES. COORDINATE INSTALLATION AND REMOVAL OF CONTRACTOR FURNISHED DUMPSTER WITH LANDLORD. 23. REPAIR, RE-ROUTE, AND EXTEND ALL SERVICES, PIPING, CONDUIT OF EXISTING ITEMS AND EQUIPMENT AS REQUIRED DURING THE CONSTRUCTION PROCESS FOR THE COMPLETE INSTALLATION AND OPERATIONS OF NEW EQUIPMENT. THIS INCLUDES ALL ITEMS SHOWN OR NOT SHOWN ON THE DRAWINGS. RESET EXISTING EQUIPMENT OR RELATED ITEMS AS REQUIRED FOR PROPER OPERATION. 24. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE TIMELY ORDERING OF MATERIALS TO PROHIBIT DELAYS OF THE CONSTRUCTION SCHEDULE OF THIS PROJECT. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO COORDINATE DELIVERY OF MATERIALS IN A TIMELY MANNER. 25. THE GENERAL CONTRACTOR SHALL RESPOND TO ALL REQUIREMENTS OF THE ENGINEER/ARCHITECT FOR VERIFICATIONS, RESPONSES AND SUBMISSIONS. 26. DURING ENTIRE CONSTRUCTION PERIOD, PROVIDE ONE U.L. LISTED 2A:20BC DRY CHEMICAL FIRE EXTINGUISHER, OR ONE STANDARD U.L. LISTED 2-1/2 GALLON WATER (E-1 0) AND ONE U.L. LISTED 1 OBC CARBON DIOXIDE FIRE EXTINGUISHER MOUNTED TOGETHER IN EACH 3000 SQ. FT. OF WORK AREA OR FRACTION THEREOF (MINIMUM OF TWO AVAILABLE IN ALL CONSTRUCTION AREAS AT ALL TIMES.) 27. IF MODIFICATION TO SPRINKLER SYSTEM (WHEN SPRINKLED) IS REQUIRED, GENERAL CONTRACTOR SHALL HIRE A LICENSED SPRINKLER CONTRACTOR. SPRINKLER CONTRACTOR TO SUBMIT SIGNED AND SEALED SPRINKLER DRAWINGS TO THE ARCHITECT FOR APPROVAL PRIOR TO ANY ALTERATION OF THE AUTOMATIC SPRINKLER SYSTEM. WORK TO BE DONE UNDER SEPARATE PERMIT. 28. CONTRACTOR IS RESPONSIBLE FOR PROTECTING ADJACENT PREMISES FROM MOISTURE, CONSTRUCTION NOISE, DUST AND DEBRIS. 29. ANY DAMAGE CAUSED BY THE CONTRACTOR TO EXISTING FACILITY TO REMAIN SHALL BE REPAIRED TO BEFORE DAMAGE CONDITIONS AT THE CONTRACTOR'S SOLE EXPENSE. 30. COORDINATE ALL WORK TO BE DONE WITH ALL THE CONTRACTORS INVOLVED PRIOR TO INSTALLATION. 31. FIELD VERIFY LOCATIONS OF PIPING, EQUIPMENT, STRUCTURAL COMPONENTS, ETC. PRIOR TO COMMENCING ANY WORK. SECTION 00 72 00 - GENERAL CONDITIONS OF THE CONTRACT FOR CONSTRUCTION "General Conditions of the Contract for Construction', AIA A201 is hereby made a part of these documents as if bound herein. Copies of the AIA A201 can 31. PROVIDE ADA COMPLIANT PRO WRAP DRAIN AND STOP INSULATION SYSTEM OR be obtained from Owners Representative. DRAINSHEILD ON ALL LAVATORIES. END OF SECTION 00 72 00 32. ALL SPECIFIED ELECTRICAL NOTES ARE REQUIRED, ALL EQUIPMENT AND OUTLETS ARE TO SECTION 01 20 00 - PRICE AND PAYMENT PROCEDURES BE PLACED BY GENERAL CONTRACTOR. PART 1 - GENERAL 33. FIRE EXTINGUISHERS, SMOKE AND FIRE DETECTION SYSTEMS TO BE INSTALLED BY GENERAL 1.1 CONTRACT MODIFICATION PROCEDURES CONTRACTOR PER LOCAL CODE. A. On Owner's approval of a proposal from Contractor on AIA Document G709, Architect will issue a Change Order on AIA Document G701, for all changes to the Contract Sum or the Contract Time. 34. ALL DIMENSIONS TO BE VERIFIED BY GENERAL CONTRACTOR ON SITE. B. When Owner and Contractor disagree on the terms of a proposal, Architect may issue a Construction Change Directive on AIA Document G714, instructing 35. GENERAL CONTRACTOR SHALL MAKE FINAL CONNECTIONS TO ALL OWNER FURNISHED Contractor to proceed with the change, for subsequent inclusion in a Change Order. Construction Change Directive will contain a description of the change and ITEMS. designate the method to be followed to determine changes to the Contract Sum or the Contract Time. 1.2 PAYMENT PROCEDURES 36. GENERAL CONTRACTOR IS RESPONSIBLE TO COORDINATE DELIVERY, RECEIVE, UNLOAD, A. Submit a Schedule of Values at least 1 0 days before the initial Application for Payment. Break down the Contract Sum into at least one line item for each STORE, PROTECT ITEMS CALLED FOR IN SCOPE OF WORK FROM THE DELIVERY TRUCK INTO STORAGE AND THROUGH THE COMPLETE INSTALLATION PROCESS, ANY ITEMS Specification Section in the Project Manual table of contents. Coordinate the Schedule of Values with Contractors Construction Schedule. DAMAGED AFTER RECEIVING BY CONTRACTOR SHALL BE REPLACED AS DETERMINED BY 1. Round amounts to nearest whole dollar; total shall equal the Contract Sum. THE OWNER, AT THE CONTRACTOR'S SOLE EXPENSE. 2. Provide separate line items in the Schedule of Values for initial cost of materials and for total installed value of that part of the Work. B. Submit 3 copies of each application for payment on AIA Document G702/703, according to the schedule established in Owner/Contractor Agreement. 37. ALL WOOD IN CONTACT WITH CONCRETE MUST BE PRESSURE TREATED MOISTURE RESISTANT. 1. With each Application for Payment, submit waivers of mechanic's liens from subcontractors, sub -subcontractors, and suppliers for construction period covered by the previous application. 38. REPAIR ROOF AT ALL ROOF PENETRATIONS AS REQUIRED TO MAINTAIN A WATERTIGHT / 2. Submit final Application for Payment after completion of Project closeout procedures with release of liens and supporting documentation. PRE- PENETRATED ROOF SYSTEM. a. Include consent of surety to final payment on AIA Document G707 and insurance certificates. b. Submit final meter readings for utilities, a record of stored fuel, and similar data as of the date of Substantial Completion. 39. RE -KEY ALL EXISTING LOCKSETS. PART 2 - PRODUCTS (Not Applicable) 40. PROVIDE SIGN ON EXTEROR DOORS STATING "DOOR TO REMAIN UNLOCKED WHILE PART 3 - EXECUTION (Not Applicable) BUILDING IS OCCUPIED", I" HIGH LETTERS. END OF SECTION 01 20 00 41. ALL DOOR HARDWARE TO MEET ADA GUIDELINES. SECTION 01 30 00 - ADMINISTRATIVE REQUIREMENTS PART 1 - GENERAL 42. PROVIDE SIGN STATING MAXIMUM OCCUPANT LOAD WHERE REQUIRED BY AUTHORITY 1. 1 PROJECT MANAGEMENT AND COORDINATION HAVING JURISDICTION. A. Coordinate construction to ensure efficient and orderly installation of each part of the Work. 43. PROVIDE FIRESTOPPING MATERIAL AT ALL PENETRATIONS OF ANY FIRE WALL. B. Schedule and conduct progress meetings at Project site at regular intervals. Notify Owner and Architect of meeting dates and times. Require attendance of each subcontractor or other entity concerned with current progress or involved with planning or coordination of future activities- 44. IF MODIFICATION TO FIRE ALARM SYSTEM (WHEN PRESENT) IS REQUIRED, GENERAL 1. Architect will record minutes and distribute to everyone concerned, including Owner and Architect. CONTRACTOR SHALL HIRE A LICENSED FIRE ALARM CONTRACTOR. FIRE ALARM 1.2 SUBMITTAL PROCEDURES CONTRACTOR TO SUBMIT SIGNED AND SEALED FIRE ALARM DRAWINGS TO THE ARCHITECT FOR APPROVAL PRIOR TO ANY ALTERATION OF THE FIRE ALARM SYSTEM. A. Coordinate each submittal with fabrication, purchasing, testing, delivery, other submittals, and related activities that require sequential activity. WORK TO BE DONE UNDER SEPARATE PERMIT. 1. No extension of the Contract Time will be authorized because of failure to transmit submittals enough in advance of the Work to permit processing, including resubmittals. 45. PROTECT EXISTING BUILDING STRUCTURAL SYSTEMS AND PROVIDE BRACING AT ALL 2. Submit three copies of each submittal. Architect will return one copy. EXISTING PARTITIONS COMPROMISED BY DEMOLITION ACTIVITIES IN ANY WAY. 3. Architect will discard submittals received from sources other than Contractor. 46. CONSTRUCTION SAFEGUARDS REQUIRED EXITS, EXISTING STRUCTURAL ELEMENTS, FIRE B. Place a permanent label or title block on each submittal for identification. Provide a space approximately 6 by 8 inches on label or beside title block to record PROTECTION DEVICES AND SANITARY SAFEGUARDS SHALL BE MAINTAINED AT ALL TIMES Contractor's review and approval markings and action taken by Architect. Include the following information on the label: DURING REMODELING, ALTERATIONS, REPAIRS OR ADDITIONS TO ANY BUILDING OR 1. Project name. STRUCTURE. EXCEPTIONS: 1. WHEN SUCH REQUIRED ELEMENTS OR DEVICES ARE BEING 2. Date. REMODELED, ALTERED OR REPAIRED, ADEQUATE SUBSTITUTE PROVISIONS SHALL BE MADE. 2. WHEN THE EXISTING BUILDING IS NOT OCCUPIED. FBC 3302.1 3. Name and address of Contractor. 4. Name and address of subcontractor or supplier. 5. Number and title of appropriate Specification Section. C. Identify deviations from the Contract Documents on submittals. ACCESSIBILITY N TES: D. Contractor's Construction Schedule Submittal Procedure: Submit two copies of schedule within 15 days after date established for Commencement ofthe Work. I . H.C. ACCESS TO THESE FACILITIES SHALL BE PROVIDED AT PRIMARY ENTRANCE PART 2 - PRODUCTS 2.1 ACTION SUBMITTALS 2. THE SLOPE OF PUBLIC WALKS SHALL NOT EXCEED MAX CROSS SLOPE 2% WALKING A. Product Data: Mark each copy to show applicable products and options. Include the following: SURFACE SLOPING GREATER THEN 2% SHALL BE SLIP RESISTANT 1. Manufacturer's written recommendations, product specifications, and installation instructions. 3. EVERY REQUIRED EXIT DOORWAY SHALL BE SIZED FOR A DOOR NOT LESS THEN 31-01 WIDE 2. Wiring diagrams showing factory -installed wiring. BY NOT LESS THEN 6-8" HIGH CAPABLE OF OPENING 9T DEGREES AND MOUNTED TO 3. Printed performance curves and operational range diagrams. THAT THE CLEAR WIDTH OF EXIT WAY IS 32'MIN. 4. Testing by recognized testing agency. 5. Compliance with specified standards and requirements. 4. THRESHOLD TO BE MAX 1/4'ABOVE ADJACENT FINISH FLOOR B. Shop Drawings: Prepare Project -specific information, drawn accurately to scale. Do not base Shop Drawings on reproductions of the Contract Documents or 5. MAXIMUM EFFORT TO OPERATE DOORS SHALL NOT EXCEED 5 LBS. standard printed data. Submit on sheets at least 8-1/2 by I I inches but no larger than 30 by 42 inches. Include the following: 1. Dimensions and identification of products. 6. THE BOTTOM I 9'OF ALL DOORS EXCEPT AUTOMATIC AND SLIDING SHALL HAVE A 2. Fabrication and installation drawings and roughing -in and setting diagrams. SMOOTH UNINTERRUPTED SURFACE. 3. Wiring diagrams showing field -installed wiring. 7. PROVIDE LEVER TYPE HARDWARE, PANIC BARS, PUSH-PULL ACTIVATING BARS, OR 4. Notation of coordination requirements. OTHER HARDWARE DESIGNED TO PROVIDE PASSAGE WITHOUT REQUIRING THE ABILITY 5. Notation of dimensions established by field measurement. TO GRASP THE OPENING HARDWARE (39- TO 44- AFF.) C. Samples: Submit Samples for review of kind, color, pattern, and texture and for a comparison of these characteristics between submittal and actual component as delivered and installed. Include name of manufacturer and product name on label. 1. If variation is inherent in material or product, submit at least three sets of paired units that show variations. 2.2 INFORMATION SUBMITTALS A. Qualification Data: Include lists of completed projects with project names and addresses, names and addresses of architects and owners, and other information specified. B. Product Certificates: Prepare written statements on manufacturer's letterhead certifying that product complies with requirements in the Contract Documents. 2.3 CONTRACTOR'S CONSTRUCTION SCHEDULE A. Gantt -Chart Schedule: Submit a comprehensive, fully developed, horizontal Ganft-chart-type schedule within 15 days of date established for commencement of the Work. B. Preparation: Indicate each significant construction activity separately. Identify first workday of each week with a continuous vertical line. PART 3 - EXECUTION 3.1 SUBMITTAL REVIEW A. Review each submittal and check for coordination with other Work of the Contract and for compliance with the Contract Documents. Note corrections and field dimensions. Mark with approval stamp before submitting to Architect. B. Architect will review each action submittal, make marks to indicate corrections or modifications required, stamp and mark as appropriate to indicate action taken, and return copies less those retained. 3.2 CONTRACTOR'S CONSTRUCTION SCHEDULE A. Distribute copies of approved schedule to Owner, Architect, subcontractors, testing and inspecting agencies, and parties identified by Contractorwith a need -to -know schedule responsibility. When revisions are made, distribute updated schedules to the same parties. B. Updating: At weekly intervals, update schedule to reflect actual construction progress and activities. Issue schedule one week before each regularly scheduled progress meeting. 1. As the Work progresses, indicate Actual Completion percentage for each activity. END OF SECTION 01 30 00 SECTION 01 42 00 - REFERENCES PART1- GENERAL 1.1 DEFINITIONS A. General: Basic Contract definitions are included in the Conditions of the Contract. B. "Approved": When used to convey Owner's action on Contractor's submittals, applications, and requests, "approved" is limited to Owner's duties and responsibilities as stated in the Conditions of the Contract. C. "Directed": A command or instruction by Owner. Other terms including "requested," "authorized," "selected," "approved," "required," and "permitted" have the same meaning as "directed." D. "Indicated": Requirements expressed by graphic representations or in written form on Drawings, in Specifications, and in other Contract Documents. Other terms including "shown," "noted," "scheduled," and "specified" have the same meaning as "indicated." E. "Regulations": Laws, ordinances, statutes, and lawful orders issued by authorities having jurisdiction, and rules, conventions, and agreements within the construction industry that control performance of the Work. F. "Furnish": Supply and deliver to Project site, ready for unloading, unpacking, assembly, installation, and similar operations. G. "Install": Operations at Project site including unloading, temporarily storing, unpacking, assembling, erecting, placing, anchoring, applying, working to dimension, finishing, curing, protecting, cleaning, and similar operations. H. "Provide": Furnish and install, complete and ready for the intended use. 1. "Project Site": Space available for performing construction activities. The extent of Project site is shown on Drawings and may or may not be identical with the description of the land on which Project is to be built. 1.2 INDUSTRY STANDARDS A. Applicability of Standards: Unless the Contract Documents include more stringent requirements, applicable construction industry standards have the same force and effect as if bound or copied directly into the Contract Documents to the extent referenced. Such standards are made a part of the Contract Documents by reference. B. Publication Dates: Comply with standards in effect as of date of the Contract Documents, unless otherwise indicated. C. Copies of Standards: Each entity engaged in construction on Project should be familiar with industry standards applicable to its construction activity. Copies of applicable standards are not bound with the Contract Documents. 1. Where copies of standards are needed to perform a required construction activity, obtain copies directly from publication source. 1.3 ABBREVIATIONS AND ACRONYMS A. Industry Organizations: Where abbreviations and acronyms are used in Specifications or other Contract Documents, they shall mean the recognized name of the entities indicated in Gale Research's "Encyclopedia of Associations" or in Columbia Books' "National Trade & Professional Associations ofthe U.S." PART 2 - PRODUCTS (Not Used) PART 3 - EXECUTION (Not Used) END OF SECTION 01 42 00 SECTION 01 50 00 - TEMPORARY FACILITIES AND CONTROLS PART 1 - GENERAL 1.1 SECTION REQUIREMENTS A. Use Charges: Cost or use charges for temporary facilities shall be included in the Contract Sum. B. Use water and electric power from Owner's existing system without metering and without payment of use charges. C. Electrical Service: Comply with NEMA, NECA, and UL standards and regulations for temporary electric service. Install service to comply with NFPA 70. PART 2 - PRODUCTS 2.1 EQUIPMENT A. Heating Equipment: Unless Owner authorizes use of permanent heating system, provide vented, self-contained heaters with thermostatic control. 1. Use of gasoline -burning space heaters, open -flame heaters, or salamander -type heating units is prohibited. 2. Heating Units: Listed and labeled, by a testing agency acceptable to authorities having jurisdiction, and marked for intended use. PART 3 - EXECUTION 3.1 TEMPORARY UTILITIES A. General: Arrange with utility company, Owner, and existing users for time when service can be interrupted, if necessary, to make connections for temporary services. B. Sanitary Facilities: Use of Owner's existing toilet facilities will be permitted, as long as facilities are cleaned and maintained in a condition acceptable to Owner. At Substantial Completion, restore these facilities to condition existing before initial use. C. Heating and Cooling: Provide temporary heating and cooling required for curing or drying of completed installations or for protecting installed construction from adverse effects of low temperatures or high humidity. Select equipment that will not have a harmful effect on completed installations or elements being installed. D. Provide temporary lighting with local switching that provides adequate illumination for construction operations, observations, inspections, and traffic conditions. 3.2 TEMPORARY SUPPORT FACILITIES A. Provide field offices, storage and fabrication sheds, and other support facilities as necessary for construction operations. B. Provide waste -collection containers in sizes adequate to handle waste from construction operations. Collect waste daily and, when containers are full, legally dispose of waste off -site. Comply with requirements of authorities having jurisdiction. C. Install project identification and other signs in locations approved by Owner and Architect to inform the public and persons seeking entrance to Project. 3.3 TEMPORARY SECURITY AND PROTECTION FACILITIES A. Provide temporary environmental protection, operate temporary facilities, and conduct construction in ways and by methods that comply with environmental regulations and that minimize possible air, waterway, and subsoil contamination or pollution or other undesirable effects. B. Provide temporary enclosures for protection of construction and workers from inclement weather and for containment of heat. C. Provide floor -to -ceiling dustproof partitions to limit dust and dirt migration and to separate areas occupied by Owner and tenants from fumes and noise. D. Comply with requirements of authorities having jurisdiction for erecting structurally adequate barricades, including warning signs and lighting. E. Remove and safely store existing window treatment during construction. 1. Clean and reinstall at time of Substantial Completion. E. Furnish and install site enclosure in a manner that will prevent easy entering except by entrance gates. F. Install and maintain temporary fire -protection facilities. Comply with NFPA 241. 3.4 TERMINATION AND REMOVAL A. Temporary Utilities: At earliest feasible time, when acceptable to Owner, change over from use of temporary service to use of permanent service. B. Remove temporary facilities and controls no later than Substantial Completion. Personnel remaining after Substantial Completion will be permitted to use permanent facilities, under conditions acceptable to Owner. END OF SECTION 01 50 00 SECTION 01 60 00 - PRODUCT REQUIREMENTS PART 1 - GENERAL 1.1 SECTION REQUIREMENTS A. The term "product" includes the terms "material," "equipment," "system," and terms of similar intent. C. Product Substitutions will only be considered when specified product is no longer available. D. Product Substitutions: Substitutions include changes in products, materials, equipment, and methods of construction from those required by the Contract Documents and proposed by Contractor after award of the Contract. 1. Submit three copies of each request for product substitution. 2. Submit requests within days after the Notice of Award. 3. Do not submit unapproved substitutions on Shop Drawings or other submittals. 4. Identify product to be replaced and show compliance with requirements for substitutions. Include a detailed comparison of significant qualities of proposed substitution with those of the Work specified, a list of changes needed to other parts of the Work required to accommodate proposed substitution, and any proposed changes in the Contract Sum or the Contract Time should the substitution be accepted. 5. Architect will review the proposed substitution and notify Contractor of its acceptance or rejection by Change Order. E. Deliver, store, and handle products using means and methods that will prevent damage, deterioration, and loss, including theft. Comply with manufacturers written instructions. 1. Schedule delivery to minimize long-term storage at Project site and to prevent overcrowding of construction spaces. 2. Deliver products to Project site in manufacturer's original sealed container or packaging, complete with labels and instructions for handling, storing, unpacking, protecting, and installing. 3. Inspect products on delivery to ensure compliance with the Contract Documents and to ensure that products are undamaged and properly protected. 4. Store materials in a manner that will not endanger Project structure. 5. Store products that are subject to damage by the elements, under cover in a weathertight enclosure above ground, with ventilation adequate to prevent condensation. F. Warranties specified in other Sections shall be in addition to, and run concurrent with, other warranties required by the Contract Documents. Manufacturers disclaimers and limitations on product warranties do not relieve Contractor of obligations under requirements of the Contract Documents. PART 2 - PRODUCTS 2.1 PRODUCT OPTIONS A. Product Selection Procedures: 1. Where Specifications name a single product or manufacturer, provide the item indicated that complies with requirements. 2. Where Specifications include a list of names of products or manufacturers, provide one of the items indicated that complies with requirements. B. Unless otherwise indicated, Architect will select color, pattern, and texture of each product from manufacturers full range of options that includes both standard and premium items. PART 3 - EXECUTION (Not Applicable) END OF SECTION 01 60 00 SECTION 01 70 00 - EXECUTION AND CLOSEOUT REQUIREMENTS PART1- GENERAL 1. 1 CLOSEOUT SUBMITTALS A. Record Drawings: Maintain a set of prints of the Contract Drawings as Record Drawings. Mark to show actual installation where installation varies from that shown originally. 1. Identify and date each Record Drawing; include the designation "PROJECT RECORD DRAWING" in a prominent location. PART 2 - PRODUCTS (Not Applicable) PART 3 - EXECUTION 3.1 EXAMINATION AND PREPARATION A. Examine substrates and conditions for compliance with manufacturer's written requirements including, but not limited to, surfaces that are sound, level, plumb, smooth, clean, and free of deleterious substances; substrates within installation tolerances; and application conditions within environmental limits. Proceed with installation only after unsatisfactory conditions have been corrected. B. Before proceeding to lay out the Work, verify layout information shown on Drawings, in relation to property survey and existing benchmarks. C. Take field measurements as required to fit the Work properly. Where fabricated products are to be fitted to other construction, verify dimensions by field measurement before fabrication and, when possible, allow for fitting and trimming during installation. 3.2 CUTTING AND PATCHING A. Do not cut structural members or operational elements without prior written approval of Architect. B. Where existing services/systems are required to be removed, relocated, or abandoned, bypass such services/systems before cutting to prevent interruption to occupied areas. C. Patch with durable seams that are as invisible as possible. Provide materials and comply with installation requirements specified in other Sections. 3.3 INSTALLATION A. Comply with manufacturer's written instructions for installation. Anchor each product securely in place, accurately located and aligned with other portions of the Work. Clean exposed surfaces and protect from damage. B. Clean Project site and work areas daily, including common areas. 3.4 FINAL CLEANING A. Complete the following cleaning operations before requesting inspection for certification of Substantial Completion: 1. Remove labels that are not permanent. 2. Clean transparent materials, including mirrors. Remove excess glazing compounds. Replace chipped or broken glass. 3. Clean exposed finishes to a dust -free condition, free of stains, films, and foreign substances. Sweep concrete floors broom clean. 4. Vacuum carpeted surfaces and wax resilient flooring. 5. Wipe surfaces of mechanical and electrical equipment. Remove excess lubrication. Clean plumbing fixtures. Clean light fixtures, lamps, globes, and reflectors. 6. Clean windows and window treatments. 7. Clean Project site, yard, and grounds, in areas disturbed by construction activities. 3.5 CLOSEOUT PROCEDURES A. Substantial Completion: Before requesting Substantial Completion inspection, complete the following: 1. Prepare a list of items to be completed and corrected (punch list), the value of items on the list, and reasons why the Work is not complete. 2. Advise Owner of pending insurance changeover requirements. 3. Submit specific warranties, maintenance service agreements, and similar documents. 4. Obtain and submit releases permitting Owner unrestricted use of the Work and access to services and utilities. Include occupancy permits, operating certificates, and similar releases. 5. Submit Record Drawings, operation and maintenance manuals, and similar final record information. 6. Deliver tools, spare parts, extra materials, and similar items. 7. Make final changeover of permanent locks and deliver keys to Owner. 8. Complete startup testing of systems. 9. Remove temporary facilities and controls. 1 0. Submit changeover information related to Owner's occupancy, use, operation, and maintenance. 1 1. Complete final cleaning requirements, including touchup painting. 12. Touch up and otherwise repair and restore marred exposed finishes to eliminate visual defects. B. Submit a written request for inspection for Substantial Completion. On receipt of request, Architect will proceed with inspection or advise Contractor of unfulfilled requirements. Architect will prepare the Certificate of Substantial Completion after inspection or will advise Contractor of items that must be completed or corrected before certificate will be issued. C. Request inspection for Final Completion, once the following are complete: 1. Submit a copy of Substantial Completion inspection list stating that each item has been completed or otherwise resolved for acceptance. 2. Instruct Owner's personnel in operation, adjustment, and maintenance of products, equipment, and systems. D. Request reinspection when the Work identified in previous inspections as incomplete is completed or corrected. E. Submit a written request for final inspection for acceptance. On receipt of request, Architect will proceed with inspection or advise Contractor of unfulfilled requirements. Architect will prepare final Certificate for Payment after inspection or will advise Contractor of items that must be completed or corrected before certificate will be issued. 3.6 DEMONSTRATION AND TRAINING A. Engage qualified instructors to instruct Owners personnel to adjust, operate, and maintain systems, subsystems, and equipment not part of a system. Include a detailed review of the following: 1. Include instruction for basis of system design and operational requirements, review of documentation, emergency procedures, operations, adjustments, troubleshooting, maintenance, and repairs. END OF SECTION 01 70 00 SECTION 01 73 29 - CUTTING AND PATCHING PART 1 - GENERAL 1.1 SUBMITTALS A. Cutting and Patching Proposal: Submit a proposal describing procedures at least I 0 days before the time cutting and patching will be performed requesting approval to proceed. Include the following information: 1. Extent: Describe cutting and patching, show how they will be performed, and indicate why they cannot be avoided. 2. Changes to In -Place Construction: Describe anticipated results. Include changes to structural elements and operating components as wel as changes in building's appearance and other significant visual elements. 3. Products: List products to be used and firms or entities that will perform the Work. 4. Dates: Indicate when cutting and patching will be performed. 5. Utility Services and Mechanical/Electrical Systems: List services/systems that cutting and patching procedures will disturb or affect. List services/systems that will be relocated and those that will be temporarily out of service. Indicate how long services/systems will be disrupted. 6. Structural Elements: Where cutting and patching involve adding reinforcement to structural elements, submit details and engineering calculations showing integration of reinforcement with original structure. 7. Architect's] Approval: Obtain approval of cutting and patching proposal before cutting and patching. Approval does not waive right to later require removal and replacement of unsatisfactory work. 1.2 QUALITY ASSURANCE A. Structural Elements: Do not cut and patch structural elements in a manner that could change their load -carrying capacity or load-defiection ratio. B. Operational Elements: Do not cut and patch operating elements and related components in a manner that results in reducing their capacity to perform as intended or that results in increased maintenance or decreased operational life or safety. C. List below is an example only. Revise to suit Project's operating systems. With advice of counsel, delete below if Architect's approval is not required. If list is deleted, delete option in paragraph above. D. Miscellaneous Elements: Do not cut and patch miscellaneous elements or related components in a manner that could change their load -carrying capacity, that results in reducing their capacity to perform as intended, or that results in increased maintenance or decreased operational life or safety. E. Visual Requirements: Do not cut and patch construction in a manner that results in visual evidence of cutting and patching. Do not cut and patch construction exposed on the exterior or in occupied spaces in a manner that would, in Architect's opinion, reduce the building's aesthetic qualities. Remove and replace construction that has been cut and patched in a visually unsatisfactory manner. 1.3 WARRANTY A. Existing Warranties: Remove, replace, patch, and repair materials and surfaces cut or damaged during cutting and patching operations, by methods and with materials so as not to void existing warranties. PART 2 - PRODUCTS 2.1 MATERIALS A. General: Comply with requirements specified in other Sections. 1. Close and patch holes and opening in existing floor, wall, and ceiling which exist or result from demolition or alteration Work, to match adjacent undisturbed surfaces. 2. Perform new Work, and restore and refinish existing Work, to comply with applicable requirements of Sections for new Work. B. In -Place Materials: Use materials identical to in -place materials. For exposed surfaces, use materials that visually match in -place adjacent surfaces to the fullest extent possible. 1. If identical materials are unavailable or cannot be used, use materials that, when installed, will match the visual and functional performance of in -place materials. PART 3 - EXECUTION 3.1 EXAMINATION A. Examine surfaces to be cut and patched and conditions under which cutting and patching are to be performed. 1. Compatibility: Before patching, verify compatibility with and suitability of substrates, including compatibility with in -place finishes or primers. 2. Proceed with installation only after unsafe or unsatisfactory conditions have been corrected. 3.2 PREPARATION A. Temporary Support: Provide temporary support of Work to be cut. B. Protection: Protect in -place construction during cutting and patching to prevent damage. Provide protection from adverse weather conditions for portions of Project that might be exposed during cutting and patching operations. C. Adjoining Areas: Avoid interference with use of adjoining areas or interruption of free passage to adjoining areas. D. Existing Utility Services and Mechanical/Electrical Systems: Where existing services/systems are required to be removed, relocated, or abandoned, bypass such services/systems before cutting to prevent interruption to occupied areas. 3.3 PERFORMANCE A. General: Employ skilled workers to perform cutting and patching. Proceed with cutting and patching at the earliest feasible time, and complete without delay. 1. Cut in -place construction to provide for installation of other components or performance of other construction, and subsequently patch as required to restore surfaces to their original condition. B. Patching: Patch construction by filling, repairing, refinishing, closing up, and similar operations following performance of other Work. Patch with durable seams that are as invisible as possible. Provide materials and comply with installation requirements specified in other Sections. 1. Inspection: Where feasible, test and inspect patched areas after completion to demonstrate integrity of installation. 2. Exposed Finishes: Restore exposed finishes of patched areas and extend finish restoration into retained adjoining construction in a manner that will eliminate evidence of patching and refinishing. 3. Floors and Walls: Where walls or partitions that are removed extend one finished area into another, patch and repair floor and wall surfaces in the new space. Provide an even surface of uniform finish, color, texture, and appearance. Remove in -place floor and wall coverings and replace with new materials, if necessary, to achieve uniform color and appearance. 4. Ceilings: Patch, repair, or rehang in -place ceilings as necessary to provide an even -plane surface of uniform appearance. 5. Exterior Building Enclosure: Patch components in a manner that restores enclosure to a weathertight condition. C. Cleaning: Clean areas and spaces where cutting and patching are performed. Completely remove paint, mortar, oils, putty, and similar materials. END OF SECTION 01 73 29 CAMPBELL +VAN DUSEN ARCHITECTURE INTERIOR DESIGN www.CVDstudio.com CAMPBELL + VAN DUSEN Design Studio, LLC. 255 South Orange Avenue Suite # 1 240 Orlando, Florida 32801 Phone: 407.930.6016 FL. Lic. No. AR001 6053 ARCHITECT OF RECORD FRANK W. CAMPBELL AIA FLLIC NO. AR0016053 COPY OF THIS PLAN IS NOT VALID UNLESS SIGNED, SEALED AND DATED BY THE ARCHITECT OF RECORD COPY OF THIS PLAN IS NOT VALID UNLESS SIGNED, SEALED AND DATED BY THE ENGINEER OF RECORD _J Li- , (/) _J _J E 2 0!� 0 >_ T: F- CL 0- = LU rV F-- r14 u I < I r) v:i L/') > LLJ LILJ I _J in = I C0 F- F- + L0 = _J __J (.) -,7 .,0 af < UJ LLJ I >-- () ) 0 >_ I = 0- � 1-0 lqq- ry C) < LU 3�: ILLJ 'O Lo 00 (y) 0- r_4 r__1 CY) CONSTRUCTION DOCUMENTS _ ; 03.24.2023 ��� DESCRIPTION IIIIIIIIIIIIIIIIIIIIIII ���� IIIIIIIIIIIIIIIIIIIIIII - M IIIIIIIIIIIIIIIIIIIIIII IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII IIIIIIIIIIIIIIIIIIIIIII ��� IIIIIIIIIIIIIIIIIIIIIII IIIIIIIIIII1IIIIIIII11IIIIIIIIIIII1IIII IIIIIIIIIIIIIIIIIIIIIII ��- IIIIIIIIIIIIIIIIIIIIIII IIIIIIIIIIIIIIIIIIIIIII IIIIIIIIIIIIIIIN PRINCIPAL IN CHARGE F. CAMPBELL .................................................................... PROJECT MANAGER M. TORRES .................................................................... NOTES A0.2 SECTION 01 7419 - CONSTRUCTION WASTE MANAGEMENT AND DISPOSAL PART 1 - GENERAL 1.1 PERFORMANCE REQUIREMENTS A. General: Develop waste management plan that results in end -of -Project rates for salvage/recycling of a minimum 50 percent by weight of total waste generated by the Work. 1.2 SUBMITTALS A. Waste Reduction Progress Reports: Concurrent with each Application for Payment, submit two copies of report. Include separate reports for demolition and construction waste. Include the following information: 1. Material category. 2. Generation point of waste. 3. Total quantity of waste in tons. 4. Quantity of waste salvaged, both estimated and actual in tons. 5. Quantity of waste recycled, both estimated and actual in tons. 6. Total quantity of waste recovered (salvaged plus recycled) in tons. 7. Total quantity of waste recovered (salvaged plus recycled) as a percentage of total waste. B. Records of Donations: Indicate receipt and acceptance of salvageable waste donated to individuals and organizations. Indicate whether organization is tax exempt. C. Recycling and Processing Facility Records: Indicate receipt and acceptance of recyclable waste by recycling and processing facilities licensed to accept them. Include manifests, weight tickets, receipts, and invoices. D. Landfill and Incinerator Disposal Records: Indicate receipt and acceptance of waste by landfills and incinerator facilities licensed to accept them. Include manifests, weight tickets, receipts, and invoices. 1.3 WASTE MANAGEMENT PLAN A. General: Develop plan consisting of waste identification, waste reduction work plan, and cost/revenue analysis. Indicate quantities by weight or volume, but use same units of measure throughout waste management plan. B. Waste Identification: Indicate anticipated types and quantities of demolition and construction waste generated by the Work. Include estimated quantities and assumptions for estimates. C. Waste Reduction Work Plan: List each type of waste and whether it will be salvaged, recycled, or disposed of in landfill or incinerator. Include points of waste generation, total quantity of each type of waste, quantity for each means of recovery, and handling and transportation procedures. 1. Salvaged Materials for Reuse: For materials that will be salvaged and reused in this Project, describe methods for preparing salvaged materials before incorporation into the Work. 2. Salvaged Materials for Donation: For materials that will be donated to individuals and organizations, include list of their names, addresses, and telephone numbers. 3. Recycled Materials: Include list of local receivers and processors and type of recycled materials each will accept. Include names, addresses, and telephone numbers. 4. Disposed Materials: Indicate how and where materials will be disposed of. Include name, address, and telephone number of each landfill and incinerator facility. 5. Handling and Transportation Procedures: Include method that will be used for separating recyclable waste including sizes of containers, container labeling, and designated location on Project site where materials separation will be located. PART 2 - PRODUCTS (Not Used) PART 3 - EXECUTION 3.1 PLAN IMPLEMENTATION A. General: Implement waste management plan. Provide handling, containers, storage, signage, transportation, and other items as required to implement waste management plan during the entire duration of the Contract. B. Training: Train workers, subcontractors, and suppliers on proper waste management procedures, as appropriate for the Work occurring at Project site. 1. Distribute waste management plan to everyone concerned within three days of submittal return. 2. Distribute waste management plan to entities when they first begin work on -site. Review plan procedures and locations established for salvage, recycling, and disposal. C. Site Access and Temporary Controls: Conduct waste management operations to ensure minimum interference with roads, streets, walks, walkways, and other adjacent occupied and used facilities. 3.2 RECYCLING DEMOLITION AND CONSTRUCTION WASTE, GENERAL A. General: Recycle paper and beverage containers used by on -site workers. B. Procedures: Separate recyclable waste from other waste materials, trash, and debris. Separate recyclable waste by type at Project site to the maximum extent practical. 1. Provide appropriately marked containers or bins for controlling recyclable waste until they are removed from Project site. Include list of acceptable and unacceptable materials at each container and bin. a. Inspect containers and bins for contamination and remove contaminated materials if found. 2. Stockpile processed materials on -site without intermixing with other materials. Place, grade, and shape stockpiles to drain surface water. Cover to prevent windblown dust. 3. Stockpile materials away from construction area. Do not store within drip line of remaining trees. 4. Store components off the ground and protect from the weather. 5. Remove recyclable waste off Owner's property and transport to recycling receiver or processor. 3.3 RECYCLING DEMOLITION WASTE A. Concrete: Remove reinforcement and other metals from concrete and sort with other metals. B. Wood Materials: Sort and stack members according to size, type, and length. Separate lumber, engineered wood products, panel products, and treated wood materials. C. Metals: Separate metals by type. 1. Structural Steel: Stack members according to size, type of member, and length. 2. Remove and dispose of bolts, nuts, washers, and other rough hardware. D. Gypsum Board: Stack large clean pieces on wood pallets and store in a dry location. Remove edge trim and sort with other metals. Remove and dispose of fasteners. E. Acoustical Ceiling Panels and Tile: Stack large clean pieces on wood pallets and store in a dry location. 1. Separate suspension system, trim, and other metals from panels and tile and sort with other metals. F. Carpet: Roll large pieces tightly after removing debris, trash, adhesive, and tack strips. 1. Store clean, dry carpet in a closed container or trailer provided by Carpet Reclamation Agency or carpet recycler. G. Equipment: Drain tanks, piping, and fixtures. Seal openings with caps or plugs. Protect equipment from exposure to weather. H. Plumbing Fixtures: Separate by type and size. 1. Piping: Reduce piping to straight lengths and store by type and size. Separate supports, hangers, valves, sprinklers, and other components by type and size J. Lighting Fixtures: Separate lamps by type and protect from breakage. K. Electrical Devices: Separate switches, receptacles, switchgear, transformers, meters, panelboards, circuit breakers, and other devices by type. L. Conduit: Reduce conduit to straight lengths and store by type and size. 3.4 RECYCLING CONSTRUCTION WASTE A. Packaging: 1. Cardboard and Boxes: Break down packaging into flat sheets. Bundle and store in a dry location. 2. Polystyrene Packaging: Separate and bag materials. 3. Pallets: As much as possible, require deliveries using pallets to remove pallets from Project site. For pallets that remain on -site, break down pallets into component wood pieces and comply with requirements for recycling wood. 4. Crates: Break down crates into component wood pieces and comply with requirements for recycling wood. B. Wood Materials: 1. Clean Cut -Offs of Lumber: Grind or chip into small pieces. 2. Clean Sawdust: Bag sawdust that does not contain painted or treated wood. C. Gypsum Board: Stack large clean pieces on wood pallets and store in a dry location. 3.5 DISPOSAL OF WASTE A. General: Except for items or materials to be salvaged, recycled, or otherwise reused, remove waste materials from Project site and legally dispose of them in a landfill or incinerator acceptable to authorities having jurisdiction. 1. Except as otherwise specified, do not allow waste materials that are to be disposed of accumulate on -site. 2. Remove and transport debris in a manner that will prevent spillage on adjacent surfaces and areas. B. Disposal: Transport waste materials off Owners property and legally dispose of them. END OF SECTION 01 74 19 SECTION 02 41 19 - SELECTIVE STRUCTURE DEMOLITION PART1- GENERAL 1.1 SECTION REQUIREMENTS A. Comply with EPA regulations and hauling and disposal regulations of authorities having jurisdiction. B. Owner will occupy portions of building immediately adjacent to selective demolition area. Conduct selective demolition so Owners operations will not be disrupted. C. It is not expected that hazardous materials will be encountered in the Work. If materials suspected of containing hazardous materials are encountered, do not disturb; immediately notify Architect and Owner. Owner will remove hazardous materials under a separate contract. PART 2 - PRODUCTS (Not Applicable) PART 3 - EXECUTION 3.1 DEMOLITION A. Maintain services/systems indicated to remain and protect them against damage during selective demolition operations. Before proceeding with demolition, provide temporary services/systems that bypass area of selective demolition and that maintain continuity of services/systems to other parts of the building. B. Locate, identify, shut off, disconnect, and cap off utility services and mechanical/electrical systems serving areas to be selectively demolished. C. Provide temporary barricades and other protection required to prevent injury to people and damage to adjacent buildings and facilities to remain. D. Provide and maintain shoring, bracing, and structural supports as required to preserve stability and prevent movement, settlement, or collapse of construction and finishes to remain or construction being demolished. E. Provide temporary weather protection to prevent water leakage and damage to structure and interior areas. F. Protect walls, ceilings, floors, and other existing finish work that are to remain. Erect and maintain dustproof partitions. Cover and protect furniture, furnishings, and equipment that have not been removed. G. Neatly cut openings and holes plumb, square, and true to dimensions required. Use cutting methods least likely to damage construction to remain or adjoining construction. H. Promptly remove demolished materials from Owners property and legally dispose of them. Do not bum demolished materials. END OF SECTION 02 41 19 06 50 00 - METAL FABRICATIONS PART� ENE AL 1.1 SE 10 !QUIREMENTS '_ A. Submittals: Sho wings showing details of fabrication and installation. op-Qra PART 2 - PRODUCTS 2.1 METALS A. Numinum Extrusions: ASTM Alloy 6063-T6. B. Numinum-Alloy Rolled Tread [at : M B 632/13 632M, Alloy 6061-T6. C. Aluminum Castings: ASTM B 6/ 26M, A 443.0-F. 2.2 GROUT A. Nonshrink, Nonmetallic Grout: ASTM C 1107; recom ded by manufacturer for exterior plications. 2.3 FABRICATION A. General: Shear and punch metals cleanly and accurately. Rem burrs and e exposed edges. Form bent -metal corners to smallest radius possible without impairing work. B. Welding: Weld comers and seams continuously. Use materials and tho hat minimize distortion and develop strength and corrosion resistance of base metals. At exposed connections, finish welds su ce smo ith contour of welded surface matching those adjacent. 2.4 STEEL AND IRON FINISHES A. Prepare uncoated ferrous metal surfaces to comply i SSPC-SP 3, "Power Tool Cleaning, d paint with a st-curing, lead- and chromate -free, universal modified -alkyd primer co ying with MPI#79. PART 3 - EXECUTION 3.1 INSTALLATION .. - A. Perform cutting, drilling, and fi - required for installing miscellaneous metal fabrications. Set metal fabrication a rately in location, alignment, and elevation; wi ges and surfaces level, plumb, true, and free of rack. B. Fit exposed conneci s accurately together to form hairline joints. C. Coat conceal rfaces of aluminum that will come into contact with grout, concrete, masonry, wood, or dissimilar metals with a coat of bituminous * t. END ECTION 05 50 00 SECTION 07 84 13 - PENETRATION FIRESTOPPING PART1- GENERAL 1.1 PERFORMANCE REQUIREMENTS A. General: For the following constructions, provide penetrating firestopping that are produced and installed to resist spread of fire according to requirements indicated, resist passage of smoke and other gases, and maintain original fire -resistance rating of assembly penetrated. 1. Fire -resistance -rated non -load -bearing walls, including partitions, with fire -protection -rated openings. 2. Comply with jurisdictional requirements for locations and firestopping systems. B. F-Rated Systems: Provide penetrating firestopping with F-ratings indicated, as determined per ASTM E 814, but not less than that equaling or exceeding fire -resistance rating of constructions penetrated. C. T-Rated Systems: For the following conditions, provide penetrating firestopping with T-ratings indicated, as well as F-ratings, as determined per ASTME 814, where systems protect penetrating items exposed to potential contact with adjacent materials in occupiable floor areas: 1. Penetrations located outside wall cavities. 2. Penetrations located in construction containing fire -protection -rated openings. 3. Penetrating items larger than 4-inch- diameter nominal pipe or 16 sq. in. in overall cross -sectional area. D. For penetrating firestopping exposed to view, traffic, moisture, and physical damage, provide products that after curing do not deteriorate when exposed to these conditions both duriong and after construction. 1. For piping penetrations for plumbing provide moisture -resistant penetrating firestopping. 2. For penetrations involving insulated piping, provide penetrating firestopping not requiring removal of insulation. E. For penetrating firestopping exposed to view, provide products with flame -spread ratings of less than 25 and smoke -developed ratings of less than 450, as determined per ASTM E 84. 1.2 SUBMITTALS A. Product Data: For each type of penetrating firestopping system product indicated. B. Shop Drawings: For each penetrating firestopping, show each kind of construction condition penetrated, relationships to adjoining construction, and kind of penetrating item. Include firestop design designation of testing and inspecting agency acceptable to authorities having jurisdiction that evidences compliance with requirements for each condition indicated. 1. Submit documentation, including illustrations, from a qualified testing and inspecting agency that is applicable to each penetrating firestopping configuration for construction and penetrating items. 2. Where Project conditions require modification of qualified testing and inspecting agency's illustration to suit a particular penetrating firestopping condition, submit illustration, with modifications marked, approved by penetrating firestopping manufacturers fire -protection engineer. C. Qualification Data: If requested by Architect, for firms and persons specified in "Quality Assurance" Article to demonstrate their capabilities and experience. Include lists of completed projects with project names and addresses, names and addresses of architects and owners, and other information specified. 1.3 QUALITY ASSURANCE A. Installer Qualifications: An experienced installer who specializes in the installation of firestop and has completed penetrating firestopping similar in material, design, and extent to that indicated for this Project and whose work has resulted in construction with a record of successful in-service performance. B. Source Limitations: Obtain penetrating firestopping, for each kind of penetration and construction condition indicated, from a single manufacturer. C. Fire -Test -Response Characteristics: Provide penetrating firestopping that comply with the following requirements and those specified in "Performance Requirements" Article: 1. Firestopping tests are performed by a qualified testing and inspecting agency. A qualified testing and inspecting agency is UL, or another agency performing testing and follow-up inspection services for firestop systems acceptable to authorities having jurisdiction. 2. Penetrating firestopping are identical to those tested per ASTM E 814. Provide rated systems complying with the following requirements: a. Penetrating firestopping products bear classification marking of qualified testing and inspecting agency. b. Penetrating firestopping correspond to those indicated by reference to penetrating firestopping system designations listed by the following: 1) UL in "Fire Resistance Directory." D. Do not cover up firestop system installations that will become concealed behind other construction until building inspector, if required by authorities having jurisdiction, have examined each installation. PART 2 - PRODUCTS 2.1 FIRESTOPPING, GENERAL A. Compatibility: Provide penetrating firestopping that are compatible with one another, with the substrates forming openings, and with the items, if any, penetrating penetrating firestopping, under conditions of service and application, as demonstrated by penetrating firestopping manufacturer based on testing and field experience. B. Accessories: Provide components for each firestop system that are needed to install fill materials and to comply with "Performance Requirements" Article. Use only components specified by firestop system manufacturer and approved by the qualified testing and inspecting agency for firestop systems indicated. Accessories include, but are not limited to, the following items: 1. Permanent forming/damming/backing materials, including the following: a. Slag4rock-wool-fiber insulation. b. Sealants used in combination with other forming/damming/backing materials to prevent leakage of fill materials in liquid state. c. Fire -rated form board. d. Fillers for sealants. 2. Temporary forming materials. 3. Substrate primers. 4. Collars. 5. Steel sleeves. 2.2 FILL MATERIALS A. General: Provide penetrating firestopping containing the types of fill materials indicated in the penetrating firestopping. Schedule at the end of Part 3 by reference to the types of materials described in this Article. Fill materials are those referred to in directories of the referenced testing and inspecting agencies as fill, void, or cavity materials. B. Latex Sealants: Single -component latex formulations that after cure do not re -emulsify during exposure to moisture. C. Firestop Devices: Factory -assembled collars formed from galvanized steel and lined with intumescent material sized to fit specific diameter of penetrant. D. Intumescent Composite Sheets: Rigid panels consisting of aluminum -foil -faced elastomeric sheet bonded to galvanized steel sheet. E. Intumescent Putties: Nonhardening dielectric, water-resistant putties containing no solvents, inorganic fibers, or silicone compounds. F. Intumescent Wrap Strips: Single -component inturnescent elastomeric sheets with aluminum foil on one side. G. Pillows/Bags: Reusable, heat -expanding pillows/bags consisting of glass -fiber cloth cases filled with a combination of mineral -fiber, water -insoluble expansion agents and fire -retardant additives. H. Silicone Foams: Multicomponent, silicone -based liquid elastomers that, when mixed, expand and cure in place to produce a flexible, nonshrinking foam. 1. Silicone Sealants: Moisture -curing, single -component, silicone -based, neutral -curing elastomeric sealants of grade indicated below: 1. Grade: Pourable (self -leveling) formulation for openings in floors and other horizontal surfaces and nonsag formulation for openings in vertical and other surfaces requiring a nonslumping, gunnable sealant, unless indicated firestop system limits use to nonsag grade for both opening conditions. PART 3 - EXECUTION 3.1 EXAMINATION A. Examine substrates and conditions, with Installer present, for compliance with requirements for opening configurations, penetrating items, substrates, and other conditions affecting performance. B. Proceed with installation only after unsatisfactory conditions have been corrected. 3.2 PREPARATION A. Surface Cleaning: Clean out openings immediately before installing penetrating firestopping to comply with written recommendations of firestop system manufacturer and the following requirements: 1. Remove from surfaces of opening substrates and from penetrating items foreign materials that could interfere with adhesion of penetrating firestopping. 2. Clean opening substrates and penetrating items to produce clean, sound surfaces capable of developing optimum bond with penetrating firestopping. Remove loose particles remaining from cleaning operation. B. Priming: Prime substrates where recommended in writing by penetrating firestopping manufacturer using that manufacturer's recommended products and methods. Confine primers to areas of bond; do not allow spillage and migration onto exposed surfaces. C. Masking Tape: Use masking tape to prevent penetrating firestopping from contacting adjoining surfaces that will remain exposed on completion of Work and that would otherwise be permanently stained or damaged by such contact or by cleaning methods used to remove smears from firestop system materials. Remove tape as soon as possible without disturbing firestop system's seal with substrates. 3.3 PENETRATING FIRESTOPPING INSTALLATION A. General: Install penetrating firestopping to comply with "Performance Requirements" Article and firestop system manufacturers written installation instructions and published drawings for products and applications indicated. B. Install forming/damming/backing materials and other accessories of types required to support fill materials during their application and in the position needed to produce cross -sectional shapes and depths required to achieve fire ratings indicated. C. Install fill materials for firestop systems by proven techniques to produce the following results: 1. Fill voids and cavities formed by openings, forming materials, accessories, and penetrating items as required to achieve fire -resistance ratings indicated. 2. Apply materials so they contact and adhere to substrates formed by openings and penetrating items. 3. For fill materials that will remain exposed after completing Work, finish 3.4 IDENTIFICATION A. Identify penetrating firestopping with pressure -sensitive, self-adhesive, preprinted vinyl labels. Attach labels permanently to surfaces of penetrated construction on both sides of each firestop system installation where labels will be visible to anyone seeking to remove penetrating items or firestop systems. Include the following information on labels: 1. The words: "Warning- Penetrating Firestopping --Do Not Disturb. Notify Building Owner of Any Damage." 2. Contractors name, address, and phone number. 3. Penetrating Firestopping designation of applicable testing and inspecting agency. 4. Date of installation. 5. Penetrabng Firestopping manufacturers name. 6. Installers name. 3.5 CLEANING AND PROTECTION A. Clean off excess fill materials adjacent to openings as Work progresses by methods and with cleaning materials that are approved in writing by Penetrating Firestopping manufacturers and that do not damage materials in which openings occur. B. Provide final protection and maintain conditions during and after installation that ensure penetrating firestopping are without damage or deterioration at time of Substantial Completion. If, despite such protection, damage or deterioration occurs, cut out and remove damaged or deteriorated penetrating firestopping immediately and install new materials to produce penetrating firestopping complying with specified requirements. END OF SECTION 07 84 13 SECTION 07 92 00 - JOINT SEALANTS PART1- GENERAL 1.1 SECTION REQUIREMENTS A. Submittals: Product Data and color Samples. B. Environmental Limitations: Do not proceed with installation of joint sealants when ambient and substrate temperature conditions are outside limits permitted by joint sealant manufacturer or are below 40 deg F. PART 2 - PRODUCTS 2.1 JOINT SEALANTS A. Compatibility: Provide joint sealants, joint fillers, and other related materials that are compatible with one another and with joint substrates under service and application conditions. C. Sealant for Use in Interior Joints in Ceramic Tile and Other Hard Surfaces in Toilet Rooms and Around Plumbing Fixtures: 1. Single -component, mildew -resistant silicone sealant, ASTM C 920, Type S; Grade NS; Class 25; Uses NT, G, A, and 0; formulated with fungicide. D. Sealant for Interior Use at Perimeters of Door and Window Frames: 1. Latex sealant, single -component, nonsag, mildew -resistant, paintable, acrylic -emulsion sealant complying with ASTMI C 834. E. Acoustical Sealant for Exposed Interior Joints: 1. Nonsag, paintable, nonstaining, latex sealant complying with ASTM C 834. F. Acoustical Sealant for Concealed Joints: 1. Nondrying, nonhardening, nonskinning, nonstaining, gunnable, synthetic -rubber sealant recommended for sealing interior concealed joints to reduce transmission of airborne sound. 2.2 JOINT -SEALANT BACKING A. General: Provide sealant backings of material and type that are nonstaining; are compatible with joint substrates, sealants, primers, and otherjoint fillers; and are approved for applications indicated by sealant manufacturer. B. Cylindrical Sealant Backings: ASTM C 1330, of size and density to control sealant depth and otherwise contribute to producing optimum sealant performance. C. Bond -Breaker Tape: Polyethylene tape or other plastic tape recommended by sealant manufacturer for preventing sealant from adhering to rigid, inflexible joint -filler materials or joint surfaces at back of joint. PART 3 - EXECUTION 3.1 INSTALLATION A. Comply with ASTM C 11 93. B. Install sealants using proven techniques that comply with the following: 1. Place sealants so they directly contact and fully wet joint surfaces. 2. Completely fill recesses in each joint configuration. 3. Produce uniform depths and shapes relative to joint width. C. Comply with ASTM C 919 for use of joint sealants in acoustical applications. D. Clean off excess sealant adjacent to joints as the Work progresses by methods and cleaning materials approved in writing by manufacturer of joint sealant and of product in which joints occur. END OF SECTION 07 92 00 SECTION 08 14 16 - FLUSH WOOD DOORS PART1- GENERAL 1.1 SECTION REQUIREMENTS A. Submittals: Samples for factory -finished doors. B. Quality Standard: WDMA I.S.1-A. C. Fire -Rated Wood Doors: Labeled by a testing and inspecting agency acceptable to authorities having jurisdiction based on testing per NFPA 252. 1. At stairs and exit passageways, provide doors that have a temperature rise rating of 450 deg F. PART 2 - PRODUCTS 2.1 DOOR CONSTRUCTION, GENERAL A. WDMA I.S.1-A Performance Grade: 1. Heavy Duty unless otherwise indicated. B. Core Doors: Provide partical board lumber cores for doors, containing no ureaformaldehyde. C. Fire -Protection -Rated Doors: Provide core specified or mineral core as needed to provide fire -protection rating indicated. Provide the following for mineral -core doors: 1. Composite blocking where required to eliminate through -bolting hardware. 2. Laminated -edge construction. 3. Formed -steel edges and astragals for pairs of doors. 2.2 FLUSH WOOD DOORS A. Doors for Transparent Finish: 1. Interior Solid -Core Doors: Custom grade, five or seven -ply, structural composite lumber cores. a. Faces: Grade A species as indicated. b. Veneer Matching: Slip match, end balanced. c. Pair matching and set matching. d. Continuous matching for doors with transoms. 2.3 FABRICATION AND FINISHING A. Factory fit doors to suit frame -opening sizes indicated and to comply with clearances specified. B. Factory machine doors for hardware that is not surface applied. Locate hardware to comply with DHI-WDHS-3. C. Factory finish doors indicated for transparent finish with stain and manufacturer's standard finish complying with WDMA System TR-4, conversion varnish for grade specified for doors. PART 3 - EXECUTION 3.1 INSTALLATION A. Install doors to comply with manufacturer's written instructions, WDMA I.S.1 -A and as indicated. 1. Install fire -rated doors to comply with NFPA 80. B. Align and fit doors in frames with uniform clearances and bevels. Machine doors for hardware. Seal cut surfaces after fitting and machining. C. Clearances: As follows, unless otherwise indicated: 1. 1/8 inch at heads, jambs, and between pairs of doors. 2. 1/8 inch from bottom of door to top of decorative floor finish or covering. 3. 1/4 inch from bottom of door to top of threshold. 4. Comply with NFPA 80 for fire -rated doors. D. Repair, refinish, or replace factory -finished doors damaged during installation, as directed by Architect. END OF SECTION 08 14 16 SECTION 08 71 00 - DOOR HARDWARE PART1- GENERAL 1.1 SECTION REQUIREMENTS A. Submittals: Hardware schedule and keying schedule. B. Deliver keys to Owner. C. Fire -Resistance -Rated Assemblies: Provide products that comply with NFPA 80 and are listed and labeled by a testing and inspecting agency acceptable to authorities having jurisdiction for applications indicated. On exit devices provide label indicating "Fire Exit Hardware." PART 2 - PRODUCTS A. Hinges: 1. Hinges with stainless -steel pins for exterior. 2. Nonremovable hinge pins for exterior and public interior exposure. 3. Ball -bearing hinges for doors with closers and entry doors. 4. 3 hinges for 1-3/4-inch- thick doors 90 inches or less in height; 4 hinges for doors more than 90 inches in height. B. Locksets and Latchsets: 1. BHMA Al 56.2, Series 4000, Grade 1 for bored locks and latches. 2. BHMA Al 56.3, Grade 1 for exit devices. 3. BHMA Al 56.5, Grade 1 for auxiliary locks. 4. BHMA Al 56.13, Series 1 000, Grade 1 for mortise locks and latches. 5. Lever handles on locksets and latchsets. 6. Provide trim on exit devices matching locksets. C. Key locks to Owner's new master -key system. 1. Cylinders with six -pin tumblers and removable cores. 2. Provide cylinders for overhead doors, storefront doors, and other locking doors that do not require other hardware. D. Closers: 1. Mount closers on interior side (room side) of door opening. Provide regular -arm, parallel -arm, or top -jamb -mounted closers as necessary. 2. Adjustable delayed opening (accessible to people with disabilities) feature on closers. E. Provide wall stops or floor stops for doors without closers. F. Provide hardware finishes as indicated. PART 3 - EXECUTION 3.1 INSTALLATION A. Mount hardware in locations recommended by the Door and Hardware Institute unless otherwise indicated. END OF SECTION 08 71 00 SECTION 08 80 00 - GLAZING PART 1 - GENERAL (Not Applicable) 1.1 SECTION REQUIREMENTS A. Glass Thickness: Comply with ASTM C1 036 for glass lites. 1. Deflection subject to rejection by Architect. PART 2 - PRODUCTS 2.1 GLASS A. Heat -Treated Float Glass: ASTM C 1048, Condition A (uncoated) or Condition C (coated), Type 1, Class 1 (clear) or Class 2 (tinted), Quality Q3, Kind FT (fully tempered) as indicated. PART 3 - EXECUTION 3.1 INSTALLATION A. Comply with combined recommendations of manufacturers of glass, sealants, gaskets, and other glazing materials, unless more stringent requirements are contained in GANA's "Glazing Manual." B. Set glass lites in each series with uniform pattern, draw, bow, and similar characteristics. C. Remove nonpermanent labels, and clean surfaces immediately after installation. END OF SECTION 08 80 00 SECTION 08 83 00 - MIRRORS PART 1 - GENERAL 1.1 SUBMITTALS A. Product Data: For mirror hardware. 1.2 QUALITY ASSURANCE A. Glazing Publications: Comply with GANA's "Glazing Manual" and GANA Mirror Division's "Mirrors, Handle with Extreme Care: Tips for the Professional on the Care and Handling of Mirrors" unless more stringent requirements are indicated PART 2 - PRODUCTS 2.1 SILVERED FLAT GLASS MIRROR MATERIALS A. Clear Glass Mirrors: ASTM C 1503, Mirror Glazing Quality. 2.2 MISCELLANEOUS MATERIALS A. Setting Blocks: Elastomeric material with a Type A Shore durometer hardness of 85, plus or minus 5. B. Edge Sealer: Coating compatible with glass coating and approved by mirror manufacturer for use in protecting against silver deterioration at mirrored glass edges. C. Mirror Mastic: An adhesive setting compound, produced specifically for setting mirrors and certified by both mirror manufacturer and mastic manufacturer as compatible with glass coating and substrates on which mirrors will be installed. 2.3 MIRROR HARDWARE A. Mirror Clips: As indicated. B. Mirror Standoff: As indicated. C. Fasteners: Fabricated of same basic metal and alloy as fastened metal and matching it in finished color and texture where fasteners are exposed. D. Anchors and Inserts: Provide devices as required for mirror hardware installation. Provide toothed or lead -shield expansion -bolt devices for drilled -in -place anchors. Provide galvanized anchors and inserts for applications on inside face of exterior walls and where indicated. 2.4 FABRICATION A. Mirror Sizes: To suit Project conditions, cut mirrors to final sizes and shapes. B. Cutouts: Fabricate cutouts for notches and holes in mirrors without marring visible surfaces. Locate and size cutouts so they fit closely around penetrations in mirrors. Cutouts to be approved by Architect. C. Mirror Edge Treatment: Rounded polished edge. 1. Seal edges of mirrors after edge treatment to prevent chemical or atmospheric penetration of glass coating. PART 3 - EXECUTION 3.1 INSTALLATION A. General: Install mirrors to comply with mirror manufacturer's written instructions and with referenced GANA publications. Mount mirrors accurately in place in a manner that avoids distorting reflected images. B. Provide a minimum air space of 1/8 inch (3 mm) between back of mirrors and mounting surface for air circulation between back of mirrors and face of mounting surface. C. For wall -mounted mirrors, install with mirror hardware. 1. Attach mirror hardware securely to mounting surfaces with mechanical fasteners installed with anchors or inserts as applicable. Install fasteners so heads do not impose point loads on backs of mirrors. D. Protect mirrors from breakage and contaminating substances resulting from construction operations. E. Do not permit edges of mirrors to be exposed to standing water. F. Maintain environmental conditions that will prevent mirrors from being exposed to moisture from condensation or other sources for continuous periods of time. END OF SECTION 08 83 00 SECTION 09 22 16 - NON-STRUCTURAL METAL FRAMING PARTI- GENERAL 1.1 SECTION REQUIREMENTS A. Submittals: Product Data. B. Fire -Resistance -Rated Assemblies: Provide materials and construction identical to those tested in assemblies per ASTM E 119 by an independent testing and inspecting agency acceptable to authorities having jurisdiction. PART 2 - PRODUCTS 2.1 METAL FRAMING AND SUPPORTS A. Steel Framing Members, General: ASTM C 754. 1. Steel Sheet Components: ASTM C 645. Thickness specified is minimum uncoated base -metal thickness. 2. Protective Coating: ASTM A 653/A 653M, G40, hot -dip galvanized zinc coating. B. Suspended Ceiling and Soffit Framing: 1. Tie Wire: ASTM A 641/A 641M, Class 1 zinc coating, soft temper, 0.0625-inch diameter, or double strand of 0.0475-inch- diameter wire. 2. Wire Hangers: ASTM A 641 /A 641 M, Class I zinc coating, soft temper, and 0. 1 62-inch diameter. 3. Carrying Channels: Cold -rolled steel, 0.0538 inch thick. C. Partition and Soffit Framing: 1. Studs and Runners: In depth and thickness as indicated. 2. Flat Strap and Backing: 0.0179 inch thick. 3. Rigid Hat -Shaped Furring Channels: In depth indicated and 0.0179 inch thick. 4. Resilient Furring Channels: 1/2 inch deep, with single- or double -leg configuration. 5. Cold -Rolled Furring Channels: 0.0538 inch thick, 3/4 inch deep. 6. Z-Furring: In depth required by insulation, 1-1/4-inch face flange, 7/8-inch wall -attachment flange, and 0.0179 inch thick. 2.2 ACCESSORIES A. General: Comply with referenced installation standards. 1. Fasteners for Metal Framing: Of type, material, size, corrosion resistance, holding power, and other properties required to fasten steel members to substrates. PART 3 - EXECUTION 3.1 INSTALLATION A. Install steel framing to comply with ASTM C 754 and with ASTM C 840 requirements that apply to framing installation and with United States Gypsum's "Gypsum Construction Handbook." B. Install supplementary framing, and blocking to support fixtures, equipment services, heavy trim, grab bars, toilet accessories, furnishings, or similar construction. C. Isolate steel framing from building structure, except at floor, to prevent transfer of loading imposed by structural movement. D. Fire -Resistance -Rated Assemblies: Comply with requirements of listed assemblies. END OF SECTION 09 22 16 SECTION 09 29 00 - GYPSUM BOARD PART 1 - GENERAL 1.1 SECTION REQUIREMENTS A. Submittals: Product Data. B. Fire -Resistance -Rated Assemblies: Provide materials and construction identical to those tested in assemblies per ASTM E 119 by an independent testing and inspecting agency acceptable to authorities having jurisdiction. C. STC-Rated Assemblies: Provide materials and construction identical to those tested in assemblies per ASTM E 90 and classified per ASTM E 413 b qualified independent testing and inspecting agency. PART 2 - PRODUCTS 2.1 PANEL PRODUCTS A. Provide in maximum lengths available to minimize end -to -end butt joints. B. Interior Gypsum Board: ASTM C 36/C 36M or ASTM C 1396/C 1396M, in thickness indicated, with manufacturers standard edges. Type X where indicated and Sag -resistant type for ceiling surfaces. 2.2 ACCESSORIES A. Trim Accessories: ASTMI C 1047, formed from galvanized or aluminum -coated steel sheet, rolled zinc, plastic, or paper -faced galvanized -steel sheei For exterior trim, use accessories formed from hot -dip galvanized -steel sheet, plastic, or rolled zinc. 1. Provide comerbead at outside comers unless otherwise indicated. 2. Provide LC -bead (J-bead) at exposed panel edges. : A o.r-roviueCO"LrOijoinLsvvi,eicinuL,CILU . B. Aluminum Accessories: Extruded -aluminum accessories indicated with Class 11, clear anodic finish; AA-C12C22A31. CAMPBELL + VAN DUSEN C. Joint -Treatment Materials: ASTM C 475/C 475M. ARCHITECTURE INTERIOR DESIGN 1. Joint Tape: Paper unless otherwise recommended by panel manufacturer. 2. Joint Compounds: Drying -type, ready -mixed, all-purpose compounds. 3. Skim Coat: For final coat of Level 5 finish, use high -build interior coating product designed for application by aidess sprayer and to be used instead of skim coat to produce Level 5 finish. D. Acoustical Sealant for Exposed and Concealed Joints: Nonsag, paintable, nons ining latex sealant complying with ASTM C 834. CAMPBELL + VAN DUSEN Design Studio, LLC. E. Sound -Attenuation Blankets: ASTM C 665, Type I (unfaced). 255 South Orange Avenue Suite # 1 240 PART 3 - EXECUTION 3.1 INSTALLATION Orlando, Florida 32801 A. Install gypsum board to comply with ASTM C 840. Phone: 407.930.6016 1. Isolate gypsum board assemblies from abutting structural and masonry work. Provide edge trim and acoustical sealant. FL. Lic. No. AROO 1 6053 22. z3ingle-Layer Fas ning Methods: Fasten gypsum panels supports with screws. 3. Multilayer Fastening Methods: Fasten base layers and face layer separately to supports with screws. B. Fire -Resistance -Rated Assemblies: Comply with requirements of listed assemblies. C. Finishing Gypsum Board: ASTM C 840. 1. At concealed areas, unless a higher level of finish is required for fire -resistance -rated assemblies, provide Level 1 finish: Embed tape at joints. 2. At substrates for tile, provide Level 2 finish: Embed tape and apply separate first coat of joint compound to tape, fasteners, and trim flanges. 3. Unless otherwise indicated, provide Level 4 finish: Embed tape and apply separate first, fill, and finish coats of joint compound to tape, fasteners, and trim flanges. 4. Where indicated, provide Level 5 finish: Embed tape and apply separate first, fill, and finish coats of joint compound to tape, fasteners, and trim flanges. Apply skim coat to entire surface. END OF SECTION 09 29 00 SECTION 09 30 00 - TILING PART1- GENERAL 1.1 SECTION REQUIREMENTS A. Submittals: Product Data for tile and installation materials and Samples for tile. B. Floor Tiles: Static coefficient of friction not less than 0.6 for level surfaces and 0.8 for ramps, per ASTM C 1028. PART 2 - PRODUCTS 2.1 TILE A. Tile that complies with Standard grade requirements in ANSI Al 37. 1, "Specifications for Ceramic Tile." 2.2 INSTALLATION MATERIALS A. VOC Limit for Adhesives and Fluid -Applied Waterproofing Membranes: 65 g/L when calculated according to 40 CFR 59, Subpart D (EPA Method 24). B. Crack -Suppression Membranes for Thin -Set Tile Installation: Manufacturers standard fabric -reinforced liquid latex product complying with ANSI Al 18.1 0. 1. Install for flooring tiles of 12 by 12 or larger. C. Setting and Grouting Materials: Comply with material standards in ANSI's "Specifications for the Installation of Ceramic Tile" that apply to materials and methods indicated wiht low voc content. 1. Thin -Set Mortar Type: Latex-portland cement. 2. Grout Type: Polymer modified unless otherwise indicated. 3. Grout Color: As indicated on Finish Schedule. D. Metal Edge Strips: Angle of L-Shap, height to match tile and setting -bed thickness, metal designed specifically for flooring application. E. Grout Sealer: Manufacturers standard product for sealing grout joints and that does not change color or appearance of grout. PART 3 - EXECUTION 3.1 INSTALLATION A. Comply with tile installation standards in ANSI's "Specifications for the Installation of Ceramic Tile" that apply to materials and methods indicated. 1. For installations indicated below, follow procedures in ANSI's "Specifications for the Installation of Ceramic Tile" for providing 95 percent mortar coverage. a. Tile floors composed of tiles 8 by 8 inches or larger. b. Tile floors composed of rib -backed tiles. B. Comply with TCA's "Handbook for Ceramic Tile Installation." C. Floor Tile Installation Method(s): 1. Over Concrete Subfloors: TCA F1 13 (thin -set mortar on concrete). 2. Over Concrete Subfloors for Floor Tile 12 by 12 Inches or Larger: TCA F122 thin -set mortar over crack suppression membrane on concrete. D. Wall Tile Installation Method(s): 1. Over Gypsum Board: TCA W242 (organic adhesive on gypsum board and metal studs). 2. Over Glass -Mat, Water -Resistant Backer Board: TCA W245 with thin -set mortar (thin -set mortar on glass -mat, water-resistant backer board). E. Install tiles on floors as selected by architect. F. Install tiles on walls as selected by architect. G. Lay tile in grid pattern, unless otherwise indicated. Align joints where adjoining tiles on floor, base, walls, and trim are the same size. H. Perform rutting and drilling of tile without marring visible surfaces. Carefully grind cut edges of tile abutting trim, finish, or built-in items for straight aligned joints. Fit tile closely to electrical outlets, piping, fixtures, and other penetrations so plates, collars, or covers overlap tile. END OF SECTION 09 30 00 SECTION 09 61 13 - ACOUSTICAL PANEL CEILINGS PART 1-GENERAL 1.1 SECTION REQUIREMENTS A. Submittals: Product Data and material Samples. B. Surface -Burning Characteristics of Panels: ASTM E 1264, Class A materials, tested per ASTM E 84. C. Fire -Resistance -Rated Assemblies: Provide materials and construction identical to those tested in assemblies per ASTM E 119 by an independent testing and inspecting agency acceptable to authorities having jurisdiction. D. Seismic Standard: Provide acoustical panel ceilings designed and installed to withstand the effects of earthquake motions according to the following: 1. CISCA's Recommendations for Acoustical Ceilings: Comply with CISCA's "Recommendations for Direct -Hung Acoustical Tile and Lay -in Panel Ceilings". PART 2 - PRODUCTS 2.1 ACOUSTICAL PANELS A. Provide acoustical panels and suspension system as indicated on Finish Schedule. B. Attachment Devices: Sized for 5 times the design load indicated in ASTM C 635, Table 1, Direct Hung, unless otherwise indicated. Comply with seismic design requirements. C. Wire Hangers, Braces, and Ties: Zinc -coated carbon -steel wire; ASTM A 641 /A 641 M, Class 1 zinc coating, soft temper. D. Seismic Struts: Manufacturers standard product designed to accommodate seismic forces. E. Seismic Clips: Manufacturer's standard seismic clips designed to secure panels in place. F. Roll -Formed, Sheet -Metal Edge Moldings and Trim: Type and profile indicated or, if not indicated, manufacturer's standard moldings for edges and penetratons that comply with seismic design requirements; formed from sheet metal of same material, finish, and color as that used for exposed flangesof suspension system runners. G. Extruded -Aluminum Edge Moldings and Trim: Where indicated, provide manufacturers extruded -aluminum edge moldings and trim of profile indicated or referenced by manufacturer's designations, including splice plates, corner pieces, and attachment and other clips, complying with seismic design requirements and the following: 1. Provide trim in full lengths to elevate joint. If joints are reequired, joints to be butted and tight gaps are not acceptable. PART 3 - EXECUTION 3.1 INSTALLATION A. Ceiling Suspension System Installation: Comply with ASTM C 636 and CISCA's "Ceiling Systems Handbook." 1. Fire -Rated Assembly: Install fire -rated ceiling systems according to tested fire -rated design. B. Install acoustical panels with undamaged edges and fit accurately into suspension system runners and edge moldings. Scribe and cut panels at borders and penetrations to provide a neat, precise fit. C. Arrange directionally patterned acoustical panels as indicated on Reflective Ceiling Plan. END OF SECTION 09 51 13 SECTION 09 65 13 - RESILIENT BASE AND ACCESSORIES PART1- GENERAL 1.1 SECTION REQUIREMENTS A. Submittals: Product Data and Samples. PART 2 - PRODUCTS 2.1 RESILIENT BASE AND ACCESSORIES A. Provide resilient rubber base transition strips and accessories as indicated on Finish Schedule. B. Provide manufacturers continuous rolls. 2.2 INSTALLATION ACCESSORIES A. Trowelable Leveling and Patching Compounds: Latex -modified, portland cement- or blended hydraulic cement -based formulation provided or approved by flooring manufacturer for applications indicated. B. Adhesives: Water-resistant type containing low voc recommended by manufacturer to suit products and substrate conditions. C. Stair -Tread -Nose Filler: Two-part epoxy compound recommended by resilient tread manufacturer to fill nosing substrates that do not conform to tread contours. D. Resilient Transition Strips: Rubber, in profile as indicated. PART 3 - EXECUTION 3.1 INSTALLATION A. Prepare concrete substrates according to ASTM F 71 0. Verify that substrates are dry and free of curing compounds, sealers, and hardeners. B. Adhesively install resilient wall base and accessories. C. Install wall base in maximum lengths possible. Apply to walls, columns, pilasters, casework, and other permanent fixtures in rooms or areas where base is required. D. Install stair -tread -nose filler to nosing substrates that do not conform to tread contours. E. Install reducer strips at edges of floor coverings that would otherwise be exposed. F. Transition strips: Butt to adjacent materials and tightly adhere to substrates throughout length of each piece. END OF SECTION 09 65 13 SECTION 09 65 19 - RESILIENT TILE FLOORING PART 1 - GENERAL 1.1 SECTION REQUIREMENTS A. Submittals: Product Data and Samples. B. Fire -Test Response: Resilient tile has critical radiant flux classification of Class 1, not less than 0.45 W/sq. cm per ASTM E 648. PART 2 - PRODUCTS 2.1 RESILIENT TILE FLOORING A. Provide resilient tile flooring as indicated on Finish Schedule. 2.2 INSTALLATION ACCESSORIES A. Trowelable Leveling and Patching Compounds: Latex -modified, portland cement- or blended hydraulic cement -based formulation provided or approved by flooring manufacturer for applications indicated. B. Adhesives: Low voc water-resistant type recommended by manufacturer to suit resilient products and substrate conditions indicated. C. Metal Edge Strips: Extruded aluminum in maximum available lengths to minimize joints. PART 3 - EXECUTION 3.1 INSTALLATION A. Prepare concrete substrates according to ASTM F 71 0. Verify that substrates are dry and free of curing compounds, sealers, and hardeners. 1. Moisture Testing: Perform tests recommended by manufacturer complying with ASTM F1 869 and ASTM F2170. 2. Proceed with installation only after substrates pass testing. B. Lay out tiles so tile widths at opposite edges of room are equal and are at least one-half of a tile. C. Match tiles for color and pattern by selecting tiles from cartons in same sequence as manufactured and packaged. Lay tiles in patterns indicated. END OF SECTION 09 65 19 :�� 0 l­__ QL Q:� (.) V) LU n �_ U LU ) 0 0!� IL www.CVDsfudio.com X"�,�,,,,, I � -1 ­7 , 111�A 7 ARCHITECT OF RECORD FRANK W. CAMPBELL AIA FLLIC NO. AR0016053 COPY OF THIS PLAN IS NOT VALID UNLESS SIGNED, SEALED AND DATED BY THE ARCHITECT OF RECORD COPY OF THIS PLAN IS NOT VALID UNLESS SIGNED, SEALED AND DATED BY THE ENGINEER OF RECORD so rw MR no = 0 RM Ogg 4 + LO 1-0 I I UJ C/) I I = 0.0-0 >_ = Cl- uj r1-_J _J Li- , V) __J _J _17 13:� >_ = 0- W F-4 � 0 > _J ca __J _J < 0 � 110 11q_ NO LO 00 (y) r_1 (y) CONSTRUCTION DOCUMENTS 03.24.2023 M-110MAII � DESCRIPTION IIIIIIIIIIIIIIIIIIIIIII IIIIIIIIIIIIIIIIIIIIIIII IIII1IIIIIIIIIIIIIIII1IIIIIIIIIIIIIIIII_ IIIIIIIIIIIIIIIIIIIIIII __ IIIIIIIIIIIIIIIIIIIIIII ��� IIIIIIIIIIIIIIIIIIIIIII IIIIIIIIIIIIIIIIIIIIIII ��� - - M IIIIIIIIIIIIIIIIIIIIIII �� IIIIIIIIIIIIIIIIIIIIIII ��� ______ IIIIIIIIIIIIIIIIIIIIIII ��� IIIIIIIIIIIIIIIIII IIIIIIIIIIIIIIIIIIIIIII IIIIIIIIIIIIII1IIIIIIII1IIIIIIIIIIIIII11 PRINCIPAL IN CHARGE F. CAMPBELL .. ................................................................. PROJECT MANAGER M. TORRES .... I ............................................................... ADVENT HEALTH WELL 65+ ZEPHYRHILLS 22-0328-01 NOTES A0.3 SECTION 06 40 23 - INTERIOR ARCHITECTURAL WOODWORK PART I - GENERAL 1.1 SECTION REQUIREMENTS A. Submittals: Product Data for materials and Shop Drawings. B. Quality Standard: Architectural Woodwork Institute's "Architectural Woodwork Quality Standards". C. Environmental Limitations: Do not deliver or install woodwork until building is enclosed, wet work is completed, and HVAC system is operating. D. Provide products having a percentage of post consumer and/or preconsumer recycled content. PART 2 - PRODUCTS 2.1 MATERIALS A. Hardboard: AHAA135.4. B. Medium -Density Fiberboard: ANSI A208.2, Grade 130, made with binder containing no urea formaldehyde. C. Softwood Plywood: DOC PS 1. D. Hardwood Plywood and Face Veneers: HPVA HP-1, made with adhesive containing no urea formaldehyde. E. Thermoset Decorative Panels: Comply with LMA SAT - 1. F. High -Pressure Decorative Laminate: NEMA LD 3. G. Solid -Surfacing Material: Homogeneous solid sheets of filled plastic resin complying with ISSFA-2. 2.2 CABINET HARDWARE AND ACCESSORY MATERIALS A. Provide hardware as indicated complying with BHMA All 56.9. B. Exposed Hardware Finishes: Comply with BHMA Al 56.18 for BHMA code number indicated. C. Furring, Blocking, Shims, and Hanging Strips: Fire -retardant -treated lumber, kiln dried to 1 5 percent moisture content. D. Adhesives: Provide adhesives containing low voc content and no ureaformaledhyde. E. Provide wood products complying with FSC-accredited certification body. 2.3 INTERIOR WOODWORK A. Complete fabrication to maximum extent possible before shipment to Project site. Disassemble components only as necessary for shipment and installation. Where necessary for fitting at site, provide ample allowance for scribing, trimming, and fitting. B. Backout or groove backs of flat trim members and kerf backs of other wide, flat members, except for members with ends exposed in finished work. C. Interior Standing and Running Trim for Transparent Finish: Custom grade, species as indicated. D. Interior Standing and Running Trim for Opaque Finish: Custom grade, made from any closed -grain hardwood. E. Interior Ornamental Work for Transparent Finish: Custom grade, made from species as indicated. F. Interior Ornamental Work for Opaque Finish: Custom grade, made from any closed -grain hardwood. G. Wood Cabinets for Transparent Finish: Custom grade. 1. AW Type of Cabinet Construction: Flush overlay. 2. Wood Species and Cut for Exposed Surfaces: As indicated, and directed by Architect. 3. Grain Direction: As directed by Architect. 4. Matching of Veneer Leaves: As directed by Architect. 5. Semiexposed Surfaces Other Than Drawer Bodies: Same species and cut indicated for exposed surfaces. 6. Drawer Sides and Barks: Solid -hardwood lumber, stained to match species indicated for exposed surfaces. 7. Drawer Bottoms: Thermoset decorative panels. H. Plastic -Laminate Cabinets: Custom grade, Greenguard certified laminate. 1. AW Type of Cabinet Construction: Flush overlay. 2. Drawer Sides and Backs: Solid hardwood. 3. Drawer Bottoms: Thermoset decorative panels. 1. Plastic -Laminate Countertops: Premium grade, Greenguard certified laminate. 1. Laminate Grade: HGS for flat countertops, HGP for post -formed countertops. 2. Edge Treatment: Same as laminate cladding on horizontal surfaces. J. Solid -Surfacing Material Countertops: Custom grade. 1. Solid -Surfacing Material Thickness: 3/4 inch. 2. Fabricate tops in one piece with shop -applied edges. 2.4 SHOP FINISHING OF INTERIOR ARCHITECTURAL WOODWORK A. Finishes: Same grades as items to be finished. B. Finish architectural woodwork at the fabrication shop; defer only final touch up until after installation. 1. Apply one coat of sealer or primer to concealed surfaces of woodwork. 2. Apply two coats to back of paneling and to end -grain surfaces. 3. Apply a vinyl wash coat to woodwork made from closed -grain wood before staining and finishing. 4. After staining, if any, apply paste wood filler to open -grain woods and wipe off excess. Tint filler to match stained wood. C. Transparent Finish: AW finish system conversion varnish. PART 3 - EXECUTION 3.1 INSTALLATION A. Before installation, condition woodwork to average prevailing humidity conditions in installation areas. B. Install woodwork to comply with referenced quality standard for grade specified. C. Install woodwork level, plumb, true, and straight. Shim as required with concealed shims. Install level and plumb (including tops) to a tolerance of 1/8 inch in 96 inches. D. Scribe and cut woodwork to fit adjoining work, refinish cut surfaces, and repair damaged finish at cuts. E. Anchor woodwork to anchors or blocking built in or directly attached to substrates. Fasten with countersunk concealed fasteners and blind nailing. Use fine finishing nails for exposed nailing, countersunk and filled flush with woodwork. F. Standing and Running Trim: Install with minimum number of joints possible, using full-length pieces (from maximum length of lumber available) to greatest extent possible. Do not use pieces less than 36 inches long, except where shorter single -length pieces are necessary. Scarf running joints and stagger in adjacent and related members. G. Anchor paneling to supports with concealed panel -hanger clips and by blind nailing on back-up strips, splined-connection strips, and similar associated trim and framing. H. Cabinets: Install so doors and drawers are accurately aligned. Adjust hardware to center doors and drawers in openings and to provide unencumbered operation. 1. Fasten wall cabinets through back, near top and bottom, at ends and not more than 16 inches o.c. with [No. 1 0 wafer -head sheet metal screws through metal backing or metal framing behind wall finish. 1. Anchor countertops securely to base units. Seal space between backsplash and wall. END OF SECTION 06 40 23 SECTION 072100 - BUILDING INSULATION PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1 . Insulation. 1.2 SUBMITTALS A. Product Data: Each type of insulation specified. B. Product Test Reports: From and based on tests performed by a qualified independent testing agency evidencing compliance of insulation products with specified requirements including those for thermal resistance, fire -test -response characteristics, water absorption, and other properties, based on comprehensive testing of current products. C. Research or Evaluation Reports: Reports of the model code organization acceptable to authorities having jurisdiction that evidence compliance of foam -plastic insulations with building code in effect for Project. 1.3 QUALITY ASSURANCE A. Single -Source Responsibility for Insulation Products: Obtain each type of building insulation from a single source with resources to provide products complying with requirements indicated without delaying the Work. B. Fire -Test -Response Characteristics: Provide insulation and related materials with the fire -test- response characteristics indicated on Drawings or specified elsewhere in this Section as determined by testing identical products per test method indicated below by UL or another testing and inspecting agency acceptable to authorities having jurisdiction. Identify materials with appropriate markings of applicable testing and inspecting agency. 1 . Surface-Buming Characteristics: ASTM E 84. 2. Fire -Resistance Ratings: ASTM E 1 1 9. 3. Combustion Characteristics: ASTM E 136. 1.4 DELIVERY, STORAGE, AND HANDLING A. Protect insulation materials from physical damage and from deterioration by moisture, soiling, and other sources. Store inside and in a dry location. Comply with manufacturer's written instructions for handling, storing, and protecting during installation. 2.1 MANUFACTURERS A. Manufacturers: Subject to compliance with requirements, provide insulation products by one of the following: 1 . Sound Batt Insulation: a. CertainTeed Corporation. b. JohnsManville C. Knauf Fiber Glass GmbH. d. Owens-Corning Fiberglas Corporation. e. Schuller International, Inc. 2.2 INSULATING MATERIALS A. General: Provide insulating materials that comply with requirements and with referenced standards. 2.3 SOUND BATT INSULATION A. Sound Batt Insulation: ASTM C 665, Type I (blankets without membrane facing), Class A, with maximum fiame-spread and smoke -developed indices of 10 and 1 0, respectively, produced by combining thermosetting resins with mineral fibers manufactured from @lsee, @'a@ weel��rock wool. (Provide rock wool only) 1 . Thickness: To match cavity space indicated; provide single thickness blanket. PART 3 - EXECUTION 3.1 EXAMINATION A. Examine substrates and conditions, with Installer present, for compliance with requirements of Sections in which substrates and related work are specified and to determine if other conditions affecting performance of insulation are satisfactory. Do not proceed with installation until unsatisfactory conditions have been corrected. 3.2 PREPARATION i A. Clean substrates of substances harmful to insulation. 3.3 INSTALLATION, GENERAL A. Comply with insulation manufacturers written instructions applicable to products and application indicated. B. Install insulation that is undamaged, dry, and unsoiled C. Extend insulation in thickness indicated to envelop entire area to be insulated. Cut and fit tightly around obstructions and fill voids with insulation. Remove projections that interfere with placement. D. Apply single layer of insulation to produce thickness indicated, unless multiple layers are otherwise shown or required to make up total thickness. i 3.4 INSTALLATION OF INSULATION A. General: Apply insulation types specified to substrates indicated, complying with manufacturer's written instructions and recommendations. B. Install blanket insulation in cavities formed by framing members according to the following requirements: 1. Use blanket widths and lengths that fill the cavities formed by framing members. If more than one length is required to fill cavity, provide lengths thatwill produce a snug fit between ends. 2. Place blankets in cavities formed by framing members to produce a friction fit between edges of insulation and adjoining framing members. 3. For metal -framed wall cavities where cavity heights exceed 96 inches, support unfaced blankets mechanically. 4. Do not force or compact insulation into stud cavity. 3.5 PROTECTION A. General: Protect installed insulation from damage due to harmful weather exposures, physical abuse, and other causes. Provide temporary coverings or enclosures where insulation is subject to abuse and cannot be concealed and protected by permanent construction immediately after installation. END OF SECTION 0721 00 SECTION 09 68 13 - TILE CARPETING PARTI- GENERAL 1.1 SECTION REQUIREMENTS A. Submittals: Product Data and Samples. PART 2 - PRODUCTS 2.1 CARPET TILE A. Provide carpet tile as indicated on Finish Schedule. D. Critical Radiant Flux Classification: Not less than 0.45 W/sq. cm per ASTM E 648. PART 3 - EXECUTION 3.1 INSTALLATION A. Comply with CRI 104. B. Prepare substrates according to ASTM F710. Verify that substrates are dry and free of curing compounds, sealers, and hardeners. C. Installation Method: Glue down; releasable, pressure -sensitive adhesive. D. Install borders parallel to walls. END OF SECTION 09 68 13 SECTION 09 91 20 - PAINTING (PROFESSIONAL LINE PRODUCTS) PART1- GENERAL 1.1 SUBMITTALS A. Product Data: For each paint system indicated. B. Samples: Provide 12 by 12 inch samples of each paint color and finish. Paint sample to be applied on same type of substrate as indicated. 1.2 QUALITY ASSURANCE A. Applicator Qualifications: A firm or individual experienced in applying paints and coatings similar in material, design, and extent to those indicated for this Project, whose work has resulted in applications with a record of successful in-service performance. B. Source Limitations: Obtain primers for each coating system from the same manufacturer as the finish coats. PART 2 - PRODUCTS 2.1 MANUFACTURERS A. Products: Subject to compliance with requirements, provide one of the products listed in other Part 2 articles. B. Manufacturers' Names: Shortened versions (shown in parentheses) of the following manufacturers' names are used in other Part 2 articles: 1. ICI Paints (ICI Paints). 2. Porter Paints (Porter). 3. PPG Industries, Inc. (Pittsburgh Paints). 4. Sherwin-Williams Co. (Sherwin-Williams). 5. Flame Control Coatings, Inc. (Flame Control Coatings) 2.2 INTERIOR PRIMERS A. Interior Gypsum Board Primer: Factory -formulated latex -based primer for interior application. 1 � ICI Paints; 1 000 Prep & Prime Hi -Hide Wall Interior Water -Based Primer Sealer: Applied at a dry film thickness of not less than 1.2 mils. 2. Porter; 867 ProMaster 2000 PVA Drywall Primer Sealer: Applied at a dry film thickness of not less than 1.1 mils. 3. Pittsburgh Paints; 6-2 SpeedHide Interior Quick -Drying Latex Sealer: Applied at a dry film thickness of not less than 1.0 mil. 4. Sherwin-Williams; PrepRite High Build Interior Latex Primer/Surfacer B28W601 Series: Applied at a dry film thickness of not less than 1.6 mils. B. Interior Wood Primer for Acrylic -Enamel and Semigloss Acrylic -Enamel Finishes: Factory -formulated acrylic -latex -based interior wood primer. 1. ICI Paints; 3210 Prep & Prime Gripper Multi -Purpose Interior/Exterior Water -Based Primer Sealer: Applied at a dry film thickness of not less than 1.8 mils. 2. Porter; 1 1 29 Blanket Acrylic Primer Sealer: Applied at a dry film thickness of not less than 1.5 mils. 3. Pittsburgh Paints; 6-855 SpeedHide Latex Enamel Undercoater: Applied at a dry film thickness of not less than 1.0 mil. 4. Sherwin-Williams; PrepRite Wall and Wood Primer B49W200 Series: Applied at a dry film thickness of not less than 1.6 mils. C. Interior Ferrous -Metal Primer: Factory -formulated quick -drying rust -inhibitive acrylic -based metal primer. 1. ICI Paints; 4160 Devguard Multi -Purpose Primer: Applied at a dry film thickness of not less than 2.2 mils. 2. Porter; 215 porter Guard DTM White Acrylic Metal Primer. Applied at a dry film thickness of not less than 2.0 mils. 3. Pittsburgh Paints; 90-712 Pitt -Tech Acrylic Primer: Applied at a dry film thickness of not less than 1.5 mils. 4. Sherwin-Williams; Kern Kromik Universal Metal Primer B66W1: Applied at a dry film thickness of not less than 3.0 mils. D. Interior Zinc -Coated Metal Primer: Factory -formulated galvanized metal primer. 1. ICI Paints; 4160 Devguard Multi -Purpose Primer: Applied at a dry film thickness of not less than 2.0 mils. 2. Porter; 215 Porter Guard DTM White Acrylic Metal Primer: Applied at a dry film thickness of not less than 3.0 mils. 3. Pittsburgh Paints; 90-712 Pitt -Tech Water Borne Acrylic DTM Primer: Applied at a dry film thickness of not less than 3.0 mils. 4. Sherwin-Williams; B66W1 Direct to Metal (DTM) Acrylic Primer: Applied at a dry film thickness of not less than 3.0 mils. 2.3 INTERIOR FINISH COATS A. Interior Flat Acrylic Enamel: Factory -formulated flat acrylic -latex interior enamel: 1. ICI Paints; 1200 Dulux Professional Velvet Matte Interior Flat Latex Wall & Trim Finish: Applied at a dry film thickness of not less than 1.4 mils. 2. Pittsburgh Paints; 6-70 Line SpeedHide Interior Wall Flat -Latex Paint: Applied at a dry film thickness of not less than 1.0 mil. 3. Sherwin-Williams; ProMar 200 Interior Latex Flat Wall Paint B30W200 Series: Applied at a dry film thickness of not less than 1.4 mils. 4. Porter Paints; Pro -Master 2000 Flat Interior Latex Wall Paint No. 6109: Applied at a dry film thickness of not less than 1.3 mils. B. Interior Low -Luster Acrylic Enamel: Factory -formulated eggshell acrylic -latex interior enamel. 1. ICI Paints; 1402 Dulux Professional Acrylic Eggshell Interior Wall & Trim Enamel: Applied at a dry film thickness of not less than 1.4 mils. 2. Porter; 6129 ProMaster 2000 Acrylic Latex Eggshell Enamel: Applied at a dry film thickness of not less than 1.4 mils. 3. Pittsburgh Paints; 6-400 Series SpeedHide Eggshell Acrylic Latex Enamel: Applied at a dry film thickness of not less than 1.25 mils. 4. Sherwin-Williams; ProMar 400 Interior Latex Egg -Shell Enamel B20-4400 Series: Applied at a dry film thickness of not less than 1.6 mils. C. Interior Semigloss Acrylic Enamel: Factory -formulated semigloss acrylic -latex enamel for interior application. 1. ICI Paints; 1406 Dulux Professional Acrylic Semi -Gloss Interior Wall & Trim Enamel: Applied at a dry film thickness of not less than 1.5 mils. 2. Porter; 6139 Promaster 2000 Acrylic Latex Semi -Gloss Enamel: Applied at a dry film thickness of less than 1.5 mils. 3. Pittsburgh Paints; 6-500 Series SpeedHide Interior Semi -Gloss Latex: Applied at a dry film thickness of not less than 1.0 mil. 4. Sherwin-Williams; ProMar 400 Interior Latex Semi -Gloss Enamel B31-4400 Series: Applied at a dry film thickness of not less than 1.3 mils. PART 3 - EXECUTION 3.1 EXAMINATION A. Examine substrates, areas, and conditions, with Applicator present, for compliance with requirements for paint application. Comply with procedures specified in PDCA P4. 1. Proceed with paint application only after unsatisfactory conditions have been corrected and surfaces receiving paint are thoroughly dry. B. Coordination of Work: Review other Sections in which primers are provided to ensure compatibility of the total system for various substrates. On request, furnish information on characteristics of finish materials to ensure use of compatible primers. Notify Architect about anticipated problems when using the materials specified over substrates primed by others. 3.2 PREPARATION A. General: Remove hardware and hardware accessories, plates, machined surfaces, lighting fixtures, and similar items already installed that are not to be painted. If removal is impractical or impossible because of size or weight of the item, provide surface -applied protection before surface preparation and painting. After completing painting operations in each space or area, reinstall items removed using workers skilled in the trades involved. B. Cleaning: Before applying paint or other surface treatments, clean substrates of substances that could impair bond of the various coatings. Remove oil and grease before cleaning. C. Surface Preparation: Clean and prepare surfaces to be painted according to manufacturers written instructions for each particular substrate condition and as specified. D. Material Preparation: Mix and prepare paint materials according to manufacturer's written instructions. E. Tinting: Tint each undercoat a lighter shade to simplify identification of each coat when multiple coats of same material are applied. Tint undercoats to match the color of the finish coat, but provide sufficient differences in shade of undercoats to distinguish each separate coat. 3.3 APPLICATION A. General: Apply paint according to manufacturer's written instructions. Use applicators and techniques best suited for substrate and type of material being applied. 1. Paint colors, surface treatments, and finishes are indicated in the paint schedules. 2. Do not paint over dirt, rust, scale, grease, moisture, scuffed surfaces, or conditions detrimental to formation of a durable paint film. 3. Provide finish coats that are compatible with primers used. 4. The term "exposed surfaces" includes areas visible when permanent or built-in fixtures, grilles, convector covers, covers for finned -tube radiation, and similar components are in place. Extend coatings in these areas, as required, to maintain system integrity and provide desired protection. 5. Paint surfaces behind movable equipment and furniture the same as similar exposed surfaces. Before final installation of equipment, paint surfaces behind permanently fixed equipment or furniture with prime coat only. 6. Paint interior surfaces of ducts with a flat, nonspecular black paint where visible through registers or grilles. 7. Paint back sides of access panels and removable or hinged covers to match exposed surfaces. 8. Finish exterior doors on tops, bottoms, and side edges the same as exterior faces. B. Scheduling Painting: Apply first coat to surfaces that have been cleaned, pretreated, or otherwise prepared for painting as soon as practicable after preparation and before subsequent surface deterioration. A minimum of one prime coat and two finish coats is required. 1. The number of coats and film thickness required are the same regardless of application method. Do not apply succeeding coats until previous coat has cured as recommended by manufacturer. If sanding is required to produce a smooth, even surface according to manufacturers written instructions, sand between applications. 2. Allow sufficient time between successive coats to permit proper drying. C. Application Procedures: Apply paints and coatings by brush, roller, spray, or other applicators according to manufacturer's written instructions. D. Minimum Coating Thickness: Apply paint materials no thinner than manufacturer's recommended spreading rate to achieve dry film thickness indicated. E. Completed Work: Match approved samples for color, texture, and coverage. Remove, refinish, or repaint work not complying with requirements. 3.4 CLEANING A. Cleanup: At the end of each workday, remove empty cans, rags, rubbish, and other discarded paint materials from Project site. 1. After completing painting, clean glass and paint -spattered surfaces. Remove spattered paint by washing and scraping without scratching or damaging adjacent finished surfaces. 3.5 PROTECTION A. Protect work of other trades, whether being painted or not, against damage from painting. Correct damage by cleaning, repairing or replacing, and repainting, as approved by Architect. END OF SECTION 09 91 20 SECTION 10 44 13 - FIRE EXTINGUISHER CABINETS PART1- GENERAL 1.1 SUBMITTALS A. Product Data: For each type of product indicated. Include construction details, material descriptions, dimensions of individual components and profiles, and finishes for fire protection cabinets. 1. Fire Protection Cabinets: Include roughing -in dimensions, details showing mounting methods, relationships of box and trim to surrounding construction, door hardware, cabinet type, trim style, and panel style. B. Shop Drawings: For fire protection cabinets. Include plans, elevations, sections, details, and attachments to other work. 1.2 QUALITY ASSURANCE A. Fire -Rated, Fire Protection Cabinets: Listed and labeled to comply with requirements in ASTM E 814 for fire -resistance rating of walls where they are installed. PART 2 - PRODUCTS 2.1 MATERIALS A. Cold -Rolled Steel Sheet: ASTM A 1008/A 1008M, Commercial Steel (CS), Type B. B. Stainless -Steel Sheet: ASTM A 666, Type 304. C. Tempered Float Glass: ASTM C 1048, Kind FT, Condition A, Type 1, Quality q3, 3 mm thick, Class 1 (clear). 2.2 FIRE PROTECTION CABINET A. Cabinet Construction: To match wall receiving cabinet. 1. Fire -Rated Cabinets: Construct fire -rated cabinets with double walls fabricated from 0.0428-inch- thick, cold -rolled steel sheet lined with minimum 5/8-inch- thick, fire -barrier material. Provide factory -drilled mounting holes. B. Cabinet Material: Stainless -steel sheet. C. Cabinet Trim Material: Same material and finish as door. D. Door Material: Stainless steel as indicated. E. Door Style: Center glass panel with frame. F. Door Glazing: Tempered float glass (clear). G. Door Hardware: Manufacturer's standard. H. Accessories: 1. Mounting Bracket: Manufacturer's standard steel, designed to secure fire extinguisher to fire protection cabinet, of sizes required for types and capacities of fire extinguishers indicated, with plated or baked -enamel finish. 2. Door Lock: Cam lock that allows door to be opened during emergency by pulling sharply on door handle. 3. Identification: Lettering complying with authorities having jurisdiction for letter style, size, spacing, and location. a. Identify fire extinguisher in fire protection cabinet with the words "FIRE EXTINGUISHER", black lettering, vertically. 4. Alarm: Manufacturer's standard alarm that actuates when fire protection cabinet door is opened and that is powered by low voltage, complete with transformer. J. Finishes: 1. Steel: Factory primed for field painting. 2. Stainless Steel: No. 4. 2.3 FABRICATION A. Fire Protection Cabinets: Provide manufacturers standard box (tub) with trim, frame, door, and hardware to suit cabinet type, trim style, and door style indicated. 1. Weld joints and grind smooth. 2. Provide factory -drilled mounting holes. 3. Prepare doors and frames to receive locks. 4. Install door locks at factory. B. Cabinet Doors: Fabricate doors according to manufacturer's standards, from materials indicated and coordinated with cabinet types and trim style selected. 1. Fabricate door frames with tubular stiles and rails and hollow -metal design, minimum 1/2 inch thick. 2. Miter and weld perimeter door frames. C. Cabinet Trim: Fabricate cabinet trim in one piece with corners mitered, welded, and ground smooth. 2.4 GENERAL FINISH REQUIREMENTS A. Comply with NAAMM's "Metal Finishes Manual for Architectural and Metal Products" for recommendations for applying and designating finishes. B. Protect mechanical finishes on exposed surfaces of fire protection cabinets from damage by applying a strippable, temporary protective covering before shipping. C. Finish fire protection cabinets after assembly. D. Appearance of Finished Work: Noticeable variations in same piece are not acceptable. Variations in appearance of adjoining components are acceptable if they are within the range of approved Samples and are assembled or installed to minimize contrast. PART 3 - EXECUTION 3.1 EXAMINATION A. Examine walls and partitions for suitable framing depth and blocking where recessed cabinets will be installed. B. Proceed with installation only after unsatisfactory conditions have been corrected. 3.2 INSTALLATION A. General: Install fire protection cabinets in locations and at mounting heights indicated or, if not indicated, at heights acceptable to authorities having jurisdiction. B. Fire Protection Cabinets: Fasten cabinets to structure, square and plumb. 1. Unless otherwise indicated, provide recessed fire protection cabinets. If wall thickness is not adequate for recessed cabinets, provide semirecessed fire protection cabinets. 2. Provide inside latch and lock for break -glass panels. 3. Fasten mounting brackets to inside surface of fire protection cabinets, square and plumb. C. Identification: Vertical lettering. 3.3 ADJUSTING AND CLEANING A. Remove temporary protective coverings and strippable films, if any, as fire protection cabinets are installed unless otherwise indicated in manufacturer's written installation instructions. B. Adjust fire protection cabinet doors to operate easily without binding. Verify that integral locking devices operate properly. C. Touch up marred finishes, or replace fire protection cabinets that cannot be restored to factory -finished appearance. Use only materials and procedures recommended or furnished by fire protection cabinet and mounting bracket manufacturers. D. Replace fire protection cabinets that have been damaged or have deteriorated beyond successful repair by finish touchup or similar minor repair procedures. END OF SECTION 10 44 13 SECTION 10 44 16 - FIRE EXTINGUISHERS PART1- GENERAL 1.1 SUBMITTALS A. Product Data: For each type of product indicated. Include rating and classification, material descriptions, dimensions of individual components and profiles, and finishes for fire extinguisher. 1.2 QUALITY ASSURANCE A. NFPA Compliance: Fabricate and label fire extinguishers to comply with NFPA 1 0, "Portable Fire Extinguishers." B. Fire Extinguishers: Listed and labeled for type, rating, and classification by an independent testing agency acceptable to authorities having jurisdiction. 1. Provide fire extinguishers approved, listed, and labeled by FMG. 1.3 WARRANTY A. Special Warranty: Manufacturer's standard form in which manufacturer agrees to repair or replace fire extinguishers that fail in materials or workmanship within specified warranty period. 1. Warranty Period: Six years from date of Substantial Completion. PART 2 - PRODUCTS 2.1 PORTABLE, HAND -CARRIED FIRE EXTINGUISHERS A. Fire Extinguishers: Type, size, and capacity for each fire protection cabinet indicated. 1. Valves: Manufacturer's standard. 2. Handles and Levers: Manufacturer's standard. 3. Instruction Labels: Include pictorial marking system complying with NFPA 1 0, Appendix B and bar coding for documenting fire extinguisher location, inspections, maintenance, and recharging. B. Multipurpose Dry -Chemical Type in Steel Container: UL-rated 4-A:60-B:C, 10-lb nominal capacity, with monoammonium phosphate -based dry chemical in enameled -steel container. 1. Verify locations with Architect and comply with requirement of local authorities having jurisdiction. PART 3 - EXECUTION 3.1 EXAMINATION A. Examine fire extinguishers for proper charging and tagging. 1. Remove and replace damaged, defective, or undercharged fire extinguishers. B. Proceed with installation only after unsatisfactory conditions have been corrected. 3.2 INSTALLATION A. General: Install fire extinguishers in locations indicated and in compliance with requirements of authorities having jurisdiction. END OF SECTION 10 44 16 SECTION 11 31 00 - RESIDENTIAL APPLIANCES PART1- GENERAL 1.1 SUBMITTALS A. Product Data: For each type of product indicated. Include operating characteristics, dimensions of individual appliances, and finishes for each appliance. B. Appliance Schedule: For appliances; use same designations indicated on Drawings. 1.2 QUALITY ASSURANCE A. Source Limitations: Obtain residential appliances through one source from a single manufacturer. B. Regulatory Requirements: Comply with provisions of the following product certifications: 1. NFPA: Provide electrical appliances listed and labeled as defined in NFPA 70, Article 1 00, by a testing agency acceptable to authorities having jurisdiction, and marked for intended use. 2. UL and NEMA: Provide electrical components required as part of residential appliances that are listed and labeled by UL and that comply with applicable NEMA standards. 3. ANSI: Provide gas-buming appliances that comply with ANSI Z21 Series standards. 4. NAECA: Provide residential appliances that comply with NAECA standards. C. Regulatory Requirements, Accessibility: Where residential appliances are indicated to comply with accessibility requirements, comply with the U.S. Architectural & Transportation Barriers Compliance Board's "Americans with Disabilities Act (ADA), Accessibility Guidelines for Buildings and Facilities (ADAAG)." D. Energy Ratings: Provide residential appliances that carry labels indicating energy -cost analysis (estimated annual operating costs) and efficiency information as required by the FTC Appliance Labeling Rule. 1. Provide appliances that qualify for the EPAIDOE ENERGY STAR product labeling program. PART 2 - PRODUCTS 2.1 PRODUCTS A. Products: Provide residential appliances as indicated on drawings schedule. 2.2 FINISHES, GENERAL A. Comply with NAAMM's "Metal Finishes Manual for Architectural and Metal Products" for recommendations for applying and designating finishes. B. Protect mechanical finishes on exposed surfaces from damage by applying a strippable, temporary protective covering before shipping. PART 3 - EXECUTION 3.1 EXAMINATION A. Examine conditions, with Installer present, for compliance with requirements for installation tolerances and other conditions affecting performance of work. B. Examine roughing -in for piping systems to verify actual locations of piping connections before equipment installation. C. Proceed with installation only after unsatisfactory conditions have been corrected. 3.2 INSTALLATION, GENERAL A. General: Comply with manufacturers written instructions. B. Built-in Equipment: Securely anchor units to supporting cabinets or countertops with concealed fasteners. Verify that clearances are adequate for proper functioning and rough openings are completely concealed. C. Freestanding Equipment: Place units in final locations after finishes have been completed in each area. Verify that clearances are adequate to properly operate equipment. 3.3 CLEANING AND PROTECTION A. Test each item of residential appliances to verify proper operation. Make necessary adjustments. B. Verify that accessories required have been furnished and installed. C. Remove packing material from residential appliances and leave units in clean condition, ready for operation. END OF SECTION 11 31 00 CAMPBELL +VAN DUSEN ARCHITECTURE INTERIOR DESIGN www.CVDstudio.com CAMPBELL + VAN DUSEN Design Studio, LLC. 255 South Orange Avenue Suite # 1 240 Orlando, Florida 32801 Phone: 407.930.6016 FL. Lic. No. AR001 6053 I . X� I ,/�// ,,--I _k I ,-� I ..� -1 t, ARCHITECT OF RECORD FRANK W. CAMPBELL AIA FL LIC NO. AR001 6053 COPY OF THIS PLAN IS NOT VALID UNLESS SIGNED, SEALED AND DATED BY THE ARCHITECT OF RECORD COPY OF THIS PLAN IS NOT VALID UNLESS SIGNED, SEALED AND DATED BY THE ENGINEER OF RECORD __1 LL_ Vi J _J M _:�; I W 0 >_ = l­_ 0L CL = LU Fif �- r_4 U I < I (-) V) (/') > LIJ LU I _J 0 = 1 ca �_ F_ + L0 = __J _J (-) = ,0 Cie < LIJ ) LU �> I I >_ = C) � 0 0 LU 0- 11-0 19t ,O Lo W CL < 3: LU 17-4 00 (y) r--, (y) CONSTRUCTION DOCUMENTS 03.24.2023 ��� DESCRIPTION IIIIIIIIIIIIIIIIIIIIIIII IIIIIIIIIIIIIIIIIIIIIII ______ __ ___ IIIIIIIIIIIIIIIIIIIIIIII IIIIIIIIIIIIIIIIIIIIIIIIIII IIIIIIIIIIIIIIIIIIIIIII IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII IIIIIIIIIIIIIIIIIIIIIIII IIIIIIIIIIIIIIIIIIIIIIII III1IIIIIIIIIIIII1IIIIII1IIIIIIIIIIIII IIIIIIIIIIIIIIIIIIIIIII IIIIIIIIIIIIIIIIIIIIIII IIIIIIIIIIIIIIIIIIIIIII IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII PRINCIPAL IN CHARGE F. CAMPBELL I . ................................................................. PROJECT MANAGER M. TORRES .................................................................... ADVENT HEALTH WELL 65+ ZEPHYRHILLS 22-0328-01 NOTES A0.4 8.0000 PROVIDE SEMI -RECESSED FIRE EXTINGUISHER CABINET. B.O.D. ULINE - MODEL H5800 DUPLEX RECEPTICAL SEMI -RECESSED STEEL PAINTED (WHITE ENAMEL) IN SIDE OF NICHE LOCATE FIRE EXTINGUISHER CABINETS IN ACCORDANCE W/LOCAL CODES & PROVIDE FRAME AS SCHEDULE ARCHITECT W/ DRAWING OF LOCATIONS FOR DOUBLE STUDS AT 9.0000 REVIEW/APPROVAL PRIOR TO FRAMING OF OPENING/ 54" A. F.F. WALLS. AVOID LOCATING IN FIRE RATED OF 1 .777— PARTITION (PROVIDE SECOND LAYER OF 5/8" Zo TYPE "X" G.W.B. AT BACK SIDE OF CABINET IF FASTEN TRACK TO NOTE: NO PHYSICAL OR NOTE: NO PHYSICAL OR BOTTOM OF EXISTING CONFIRM FINAL LOCATION AND QUANTITIES 0 MECHANICAL ATTACHMENT MECHANICAL ATTACHMENT SLAB OR TRUSS BOTTOM DEVICES WITH LOCAL FIRE OFFICIAL. TO GLAZING SYSTEM SHALL BE ALLOWED. TO MULLION SHALL BE ALLOWED. CHORD I I EXISTING WINDOW---,,,,... EXISTING WINDOW YL A A WALL WALL ELEVATION EXISTING MULLION ELEVATION OF DIAGNOSTIC BOARD NICHE EXISTING GLASS EXISTING GLASS DOUBLE GALV. CAMPBELL + VAN DUSEN TYPICAL INTERIOR DOOR JAMB DETAIL DOUBLE GALV. 3 5/8" STUDS ARCHITECTURE INTERIOR DESIGN 3 5/8" STUDS VERIFY W/ MFR. USE MTL. STUD AS BRACE 8'--0" O.C. www.CVDstudio.com TFASTEN EACH BRACE GORDON TRIM MULLION MATE GORDON TRIM MULLION MATE TO TRACK WITH ONE SIZE AS REQUIRED FOR SILL DEPTH SIZE AS REQUIRED FOR SILL DEPTH SHEET METAL SCREW 255 Souf h Orange Avenue Suif e # 1240 EACH SIDE OR FASTEN I F Orlando, Florida 32801 CEILING CHANNEL/ ANGLE STUD/BRACE TO SLAB Phone: 407.930.6016 FL. Lic. No. AR001 6053 GORDON TRIM SERIES 91 l-EC-375— __1 Lj SEMI - RECESSED FIRE GORDON TRIM SERIES 911 -EC-375 EXTINGUISHER CABINET FINALFORMSI FINALFORMS1 3 5/8" METAL STUD WALL CONTOUR GWB TO CONTOUR GWB TO 1/2" RIGID INSULATIOJN PLAN W/ 5/8" GYP. BD. EACH SIDE SILL BELOW AS 3 5/8" METAL STUD WALL SILL BELOW AS BEHIND GWB. REQUIRED. REQUIRED. W/ 5/9'GYP. BD. EACH SIDE INTERIOR PARTITION N DUPLEX RECEPTICAL INTERIOR PARTITIO1 LL j IN SIDE OF NICHE FULL CORNER BEAD AROUND AS SCHEDULED AS SCHEDULEC NICHE PLAN VIE W AT DIAGNOSTIC BOARD NICHE TYPICAL INTERIOR DOOR HEAD DETAIL PARTITION TO EXTERIOR GLAZING FLASE MULLION DETAIL TYPICAL PARTITION TO EXTERIOR STOREFRONT MULLION DETAIL TYPICAL WALL/SOFFIT BRACE TO B.O. SLAB DETAILS SECTION A -A DETAILS 2 311 = 1 1-011 ��-5 3" = 1 1-011 ARCHITECT OF RECORD FRANK W. CAMPBELL AIA UNDERSIDE OF DECK UNDERSIDE OF DECK BRACE TOP OF WALL TO STRUCTURE FL LIC NO. AR001 6053 ATM, W/MTL. STUD AT 8'-0" O.C. SEE DET 4/AO.5 COPY OF THIS PLAN IS NOT VALID UNLESS SIGNED, _11111 SEALED AND DATED BY THE ARCHITECT OF RECORD ACOUSTIC SEAL BOTH SIDES ACOUSTIC SEAL BOTH SIDES 20 GA. DRYWALL RUNNER DRYWALL WRAP AT TOP & BOTTOM -A\f 20 GA. DRYWALL RUNNER V_ W/WOOD CAP OR AT TOP & BOTTOM SECURE TRACK TO STRUCTURE: SOLID SURFACE USE POWER DRIVEN FASTENERS V__T_T_ AT 24" O.C. (MAX.) SOUND BATTS FULL HT. 2X4 WOOD TOP \PLATE 1/8" x 2 3/4" FLAT HEAD METAL CEILING SEE RCP SCREW @ 16" O.C. SEALANT AROUND -5/8 BLOCKING CEILING SEE RCP PERIMETER WITH BOTTOM OF C.O. 5/8" - F-: SEE RCP FOR CEILING CONDITION 0 1E - U_ EW 0 z U_ ONE LAYER 5/8" z GYP. BD. ON ALIGN ACOUSTICAL CEILING TILE BOTH SIDES M.R. RESISTANT WITH BOTTOM OF C.O. > z AT TOILETS 0 ONE LAYER U.L. APPROVED 5/8" GYP. U_ z STORFRONT SYSTEM B.O.D. KAWNEER TRIFAB 400 BID. (BOTH SIDES) ON 3 5/8"-20 GA. SCREW SPLINE SYSTEM/FACTORY FINISH BLACK 1+ METAL STUDS @ 24" o.c. MAX C12 w CENTER GLAZED w F 3-5/8'�- 20 GA. METAL STUDS SOUND BATTS FULL HT. ALL CONCEALED WOOD ?> COPY OF THIS PLAN IS NOT VALID UNLESS SIGNED, z 7n n SEALED AND DATED BY THE ENGINEER OF RECORD PROVIDE 3/8" CLEAR TEMPERED GLASS W/ APPLIED 3M FASARA w BLOCKING TO BE FIRE TREATED PER @ 16" o.c. MAX _j w (ALLOWABLE DEFLECTION L/240) w DECORATIVE FILM. INSTALLED GLAZING SYSTEM SHALL U_ FBC2020 603 _j w > U_ RESIST 5 PSF PER 1607.14 FBC WITH MAXIMUM DEFLECTION w A SECURE TRACK TO STRUCTURE: USE POWER \Z3 5/8" STUDS @ 16" 0. w w of PER FBC 2403.4 w DRIVEN FASTENERS AT 24!' O.C. (MAX.) W/TOP AND BOTTOM w cf) SOUND BATTS FULL HT. CHANNELS SECURE TRACK TO STRUCTURE: w w > U) _j 20 GA. DRYWALL RUNNERS @ TOP 3? USE POWER DRIVEN FASTENERS U_ IT! w & BOTTOM AT 16" O.C. (MAX.) w w PER FBC 2403.4 FOR INTERIOR GLAZED AREAS THE DIFFERENTIAL SCHEDULED BASE w SCHEDULED BASE NOTE: ALL WOOD STUDS AND cl) DEFLECTION OF TWO ADJACENT UNSUPPORTED EDGES SHALL CONCEALED WOOD 5/9'GYP BOARD EA SIDE CONCRETE FLOOR SLAB NOT BE GREATER THAN THE THICKNESS OF THE PANELS WHEN A '00(/ CONCRETE FLOOR SLAB BLOCKING TO BE FIRE FORCE OF 50 POUNDS PER LINEAR FT IS APPLIED HORIZONTALLY TREATED PER FBC2020 603 TO ONE PANEL AT ANY POINT UP TO 42 INCHES ABOVE THE 5/8"- /8" 5/8" WALKING SURFACE. 5/8"), 3 /8" 5/8" 4-7/8" 4 7/8" U_ V� TYPE A - STRUCTURE TO STRUCTURE ACOUSTIC NON -RATED TYPE B - STRUCTURE TO STRUCTURE ACOUSTIC NON -RATED TYPE C - TYPICAL OFFICE STRUCTURE TO 6" ABOVE CEILING NON -RATED TYPE D - DRYWALL -WRAPPED LOW WALL W/CAP STOREFRONT GLASS PARTITION 0 r UNDERSIDE OF DECK U_j 1-4 > ACOUSTIC SEAL BOTH SIDES LU Uj 20 GA. DRYWALL RUNNER + < AT TOP & BOTTOM LU LU SOUND BATTS (FULL HT) NO CONFIRM R-30 INSULATION EXISTING AT ROOF 0 C) LU Cl- '0 Lo BRACE TOP OF WALL TO STRUCTUR IF NOT PROVIDE PIN MOUNTED VINYL FACED W/MTL. STUD AT 8'-0" O.C. SEE DET 4/AO.5 Lj-j CO (V) BATT INSULATION AS REQUIRED TO ACHIEVE r-4 r_1 m R-30. (PRODUCT TO BE CLASS A FOR FIRE) CEILING CHANNEL/ ANGLE UNDERSIDE OF DECK CEILING AS SCHEDULES, SEE RCP ROOF STRUCTURE ABOVE CONSTRUCTION DOCUMENTS ACOUSTIC SEAL BOTH SIDES EXTERIOR MASONRY WALL I /&'x 2 3/4" FLAT HEAD METAL 20 GA. DRYWALL RUNNER SCREW @ 16" O.C. AT TOP & BOTTOM 03.24.2023 BLOCKING SECURE TRACK TO STRUCTURE: WITH BOTTOM OF C.O. USE POWER DRIVEN FASTENERS co AT 24" O.C. (MAX.) NO. DATE DESCRIPTION F� ALIGN ACOUSTICAL CEILING TILE CEILING SEE RCP 0 WITH BOTTOM OF C.O. U_ z CEILING SEE RCP C =_ILING SEE RCP a. CC 0 ONE LAYER U.L. APPROVED 5/8" GYP. U_ 0 Uj U_ ONE LAYER 5/9' z z BD. (ONE SIDE) ON 1 5/8"-20 GA. z GYP. BD. ON 5 5 1 1 1 a. METAL STUDS @ 16" o.c. MAX w BOTH SIDES M.R. RESISTANT iL AT TOILETS z z 0 ONE LAYER U.L. APPROVED 5/8" GYP. PRINCIPAL IN CHARGE w FU BD. (ONE SIDE) ON 3 5/8"-20 GA. w BID. (ONE SIDE) ON 1 5/8"-20 GA. U_ BLOCKING _j 0 0 F. CAMPBELL 0 _j ONE LAYER U.L. APPROVED 5/8" GYP. _j w WITH TOP OF C.O. METAL STUDS @ 24" o.c. MAX METAL STUDS @ 16" o.c. MAX .................................................................... PR MA w w a TORRES 0 SOUND BATTS FULL HT. .................................................................... ONE LAYER 5/8" GYP. BD. ON BOTH SIDES (TYP.) w R19 UNFACED FIBREGLASS INSULATION BETWEEN STUDS w w _T 6'�- 20 GA. METAL STUDS w w F- @ 16" o.c. MAX _j _j FULL HT TO STRUCTURE ABOVE. 0 U_ w (ALLOWABLE DEFLECTION L/240) w w _j >� V U_ SECURE TRACK TO STRUCTURE: USE POWER SECURE TRACK TO STRUCTURE: USE POWER SECURE TRACK TO STRUCTURE: USE POWER w w w DRIVEN FASTENERS AT 24" O.C. (MAX.) w SOUND BATTS FULL HT. w DRIVEN FASTENERS AT 24" O.C. (MAX.) w DRIVEN FASTENERS AT 24" O.C. (MAX.) ADVENT HEALTH w W Lu SECURE TRACK TO STRUCTURE: 20 GA. DRYWALL RUNNERS @ TOP WELL 65+ U) USE POWER DRIVEN FASTENERS 20 GA. DRYWALL RUNNERS @ TOP & BOTTOM & BOTTOM SCHEDULED BASE AT 16" O.C. (MAX.) ZEPHYRHILLS SCHEDULED BASE SCHEDULED BASE SCHEDULED BASE CONCRETE FLOOR SLAB A. 40// CONCRETE FLOOR SLAB CONCRETE FLOOR SLAB CONCRETE FLOOR SLAB 5/8"- + 22-0328-01 LEI" 5/8" 5/8"- /811 5/8"- 3 /8" 5/8" [(-5 35/8 5/8" 4-7/8" 4 7/8" TYPE G 7-1/4" 2 1/2" ,'TYPE G I PARTITION TYPES/DETAILS <9> TYPE E - STRUCTURE TO STRUCTURE ACOUSTIC NON -RATED <t> TYPE F - STRUCTURE TO STRUCTURE ACOUSTIC NON -RATED <�> TYPE G - TYPICAL STRUCTURE TO 6" ABOVE CEILING NON -RATED <�> TYPE H - TYPICAL EXTERIOR WALL STRUCTURE TO STRUCTURE R-1 9 STOREFRONT GLASS PARTITION SINGLE SIDED OVER 3 5/8" METAL STUDS NON RATED SINGLE SIDED DRYWALL TO 6" ABOVE CEILING SYSTEM <0 TYPE G1 - TYPICAL STRUCTURE TO 6" ABOVE CEILING NON -RATED ('3-) WALL TYPES A/B/C/D/E/F/G/H SINGLE SIDED OVER 2 1/2" METAL STUDS 31' = 1'-01' A0.5 ELEC. ROOM/ FIRE RISER = 74 S.F. @ 300 = I P PROPOSED BUSINESS OCCUPANCY TOTAL TENANT AREA SF = 6,706 SF BUSINESS AREA: 112 PERSONS 5,360 SF@ 150 GROSS = 36P BREAK: 394 SF @ 15 NET= 27P COMMUNITY: 394 SF @ 15 NET= 27P WAITING: 233 SF @ 15 NET= 16P COMM ROOM: 83 SF @ 300 NET= I I ELEC. ROOM/F. RISER: 74 SF @ 300 NET= I P STORAGE 1: 36 SF @ 300 NET= 1 P STORAGE 2: 86 SF @ 300 NET= I P BIO: 12 SF @ 300 NET= 1 P J.C.: 34 SF @ 300 NET= I P TOTAL OCCUPANCY= 11 2P EXIT CAPACITY PROVIDED= 850P OVERALL DIAGONAL= 1191-811 DISTANCE BETWEEN EXITS= 74-6" MAX TRAVEL DISTANCE= 55'-9" LIFE SAFETY LEGEND ALL DIMENSIONS ARE ON CENTER FROM FINISHED INTERIOR SYMBOL DESCRIPTION DIRECTION OF TRAVEL TRAVEL PATH DISTANCE BETWEEN EXITS DIAGONAL DISTANCE LIGHTED EXIT SIGN: TWO SIDED, FROM DUAL DIRECTION, W/ BATTERY BACKUP. LIGHTED EXIT SIGN: SINGLE SIDED, FROM SINGLE DIRECTION, W/ BATTERY BACKUP. LIGHTED EXIT SIGN & DUAL EXIT LIGHTING COMBO: SINGLE AND OR DUAL DIRECTION W/BATTERY BACKUP. FECR NEW WALL RECESSED FIRE EXTINGUISHER KEYNOTE SYMBOL FOR SYMBOLS AND REQUIREMENTS SEE ELECTRICAL SHEETS. GENERAL NOTES THE MINIMUM FLAME SPREAD CLASSIFICATION OF INTERIOR FINISHES SHALL BE: FOR EXITS AND EXIT ACCESS CLASS B FOR ALL OTHER AREAS CLASS C KEYED NOTES PROVIDE RECESSED FIRE EXTINGUISHER CABINET. F1 0A] B.O.D. LARSENS (OCCULT SERIES WITH BLACK LETTERING) FINISH SHALL #4 304 STAINLESS STEEL. LOCATE FIRE EXTINGUISHER CABINETS IN ACCORDANCE W/LOCAL CODES & PROVIDE ARCHITECT W/ DRAWING OF LOCATIONS FOR REVIEWAPPROVAL PRIOR TO FRAMING OF WALLS. AVOID LOCATING IN FIRE RATED PARTITION (PROVIDE SECOND LAYER OF 5/8" TYPE "X" G.W.B. AT BACK SIDE OF CABINET IF LOCATING IN A FIRE RATED PARTITION). CONFIRM FINAL LOCATION AND QUANTITIES OF DEVICES WITH LOCAL FIRE OFFICIAL. CAMPBELL +VAN DUSEN ARCHITECTURE INTERIOR DESIGN www.CVDstudio.com CAMPBELL + VAN DUSEN Design Studio, LLC. 255 South Orange Avenue Suite #1240 Orlando, Florida 32801 Phone: 407.930.6016 FL. Lic. No. AR001 6053 ARCHITECT OF RECORD FRANK W. CAMPBELL AIA FLLIC NO. AR0016053 COPY OF THIS PLAN IS NOT VALID UNLESS SIGNED, SEALED AND DATED BY THE ARCHITECT OF RECORD COPY OF THIS PLAN IS NOT VALID UNLESS SIGNED, SEALED AND DATED BY THE ENGINEER OF RECORD __j U- LU r14 U < ci (/-) > LU LU -j 0 F- Lr) + �F -j (-) -'0 < LIJ LU 0 110 '0 Lf) w ,2- LU r-4 00 M rl-, (y) CONSTRUCTION DOCUMENTS 03.24.2023 PRINCIPAL IN CHARGE F. CAMPBELL .. ........................................ I ........................ PROJECT MANAGER M. TORRES ................................................................ ADVENT HEALTH WELL 65+ ZEPHYRHILLS 22-0328-01 LIFE SAFETY PLAN rl'� LIFE SAFETY PLAN AO.6 1/4" = V-0 " A0.6 4 3 10 9 8 6 5 4 A 100' — 4" :4_ A' A4 A 4 A' A A 4-. 4 14 A- ' 1 4 __r A' 4L4 FD_ 1-91 1 Vff 1 1 1 DFl-91 FD 179 do 20'— 4" 109 101 20' — 4' do 19'— 8" oe 19'— 8" 19'— 7" 10 19'— 8" .4 19'— 8" e_ c� co ftz� L ------------- j L -------------- A A 4 '�A 14 '4 A 14 -: ' z: -.t .' .4 -,4 - . 4, 4 -4 i A I A . , - - I - I - ' - 4 A 4 4 4, _ -4. . - .4' . , . - - 4" z A 4 4 A 4d ' 2t 4 4 4 , �' '4-,, - . "' . . 4 - A 4, 4 4 4 4 '14 I : - j - , 4-" A '4 4 4 7 , - , 4 - , . - 'A % - I - -, I 1 .4 -4 -4 4 'A Z4 AM A Z . 4d 4 - 4 1 A_ A" A4 -A - - - - - - - -A� - - - - --- - - - �A '4 _z 7 - - - - - - AZ -i- - - 4, -4-: - - - - - - - I -A ' 4 �4 4­ A A A -A d 4 -.A 4 44 '4 .4 A: 4 4- 4 -4: .4 'A4 4 4' 4 4 A '4� 4 _A 4 4 1 4 4 4 4 44 . "-A- 4 A 4 4 ! : . 4' 4' ' 4 A A- 44 , 4 4 .4 b r_1 0 A --(:D ) E DEMOLITION GENERAL NOTES (BOXED NOTE NUMBERS ARE KEYED TO PLAN) DI PRIOR TO THE COMMENCEMENT OF DEMOLITION, THE CONTRACTOR SHALL ACQUIRE ALL NECESSARY DEMOLITION AND BUILDING PERMITS AS DESIGNATED BY LOCAL AND STATE AUTHORITIES. ALL DEMOLITION WORK SHALL BE PERFORMED IN ACCORDANCE WITH STATE AND LOCAL REGULATIONS. ARRANGE WITH OWNER AND/OR APPROPRIATE UTILITIES FOR SERVICE SHUT -OFFS BEFORE BEGINNING DEMOLITION OPERATIONS. D2 THE CONTRACTOR SHALL COORDINATE DEMOLITION REQUIREMENTS WITH NEW CONSTRUCTION WORK SO THAT THE EXACT BOUNDARIES OF SPECIFIC DEMOLITION MAY BE DETERMINED. D3 IT IS NOT THE INTENT TO SHOW EVERY PIECE OR ITEM TO BE REMOVED IN DEMOLITION WORK. THE CONTRACTOR SHALL PERFORM ALL DEMOLITION NECESSARY TO PRODUCE THE NEW WORK AS INDICATED IN THIS CONTRACT DOCUMENT. THE DEMOLITION NOTES AND DRAWINGS SHALL NOT LIMIT THE EXTENT OF DEMOLITION REQUIRED. THEY ARE PROVIDED HERE TO INDICATE THE MAJOR INTENT OF DEMOLITION AND NOT THE SPECIFIC REQUIREMENTS THEREOF. D4 CONTRACTOR SHALL VERIFY ALL STRUCTURAL BEARING POINTS ON WALLS OR HIDDEN COLUMNS BY FIELD OBSERVATION AND SHALL BE RESPONSIBLE FOR SAFETY ON JOB SITE. D5 MECHANICAL, PLUMBING, ELECTRICAL, AND OTHER WORK RELATED TO A WALL OR SCHEDULED FOR DEMOLITION AND REMOVAL SHALL BE PERFORMED AS NEEDED TO COMPLETE REQUIRED WORK, WHETHER SO NOTED ON PLANS OR NOT. CONTRACTOR(S) SHALL INVESTIGATE EXISTING CONDITIONS FOR HIDDEN UTILITIES AND BE RESPONSIBLE FOR SAFETY ON JOB SITE AND UNDISTURBED OPERATION OF FACILITY. D6 CONTRACTOR SHALL NOTIFY ARCHITECT IF AS -BUILT FIELD CONDITIONS VARY FROM DRAWINGS. D7 PATCH/REPAIR/REFINISH ALL SURFACES EXPOSED BY DEMOLITION WORK TO MATCH AND ALIGN WITH EXISTING, ADJACENT SURFACES SCHEDULED TO REMAIN. PREPARE TO RECEIVE NEW FINISHES SPECIFIED. D8 PORTIONS OF SURFACES THAT ARE NOTED TO BE REMOVED SHALL BE SAWCUT ON A STRAIGHT/EVEN LINE AS INDICATED ON DRAWINGS TO ALLOW FOR SMOOTH TRANSITION INTO NEW MATERIALSFINISHES AS REQUIRED BY OTHER TRADES. D9 WHERE DEMOLITION OCCURS TO FACILITATE NEW CONSTRUCTION AND SUCH DEMOLITION EXPOSES CONDITIONS THAT ARE UNACCEPTABLE, BELOW STANDARDS OF CONSTRUCTION, NOT IN COMPLIANCE WITH THE CODES, OR IN GENERAL NEED OF REPAIR AND INADEQUATE TO FACILITATE NEW CONTRUCTION, CONTRACTOR SHALL NOTIFY THE OWNER AND ARCHITECT SO THAT SUCH AREAS MAY BE MODIFIED AND/OR REPLACED TO CONFORM TO ACCEPTABLE STANDARDS. DIO CONTRACTOR SHALL CONTACT BUILDING OWNER TO ASCERTAIN OWNER'S SCHEDULING RESTRICTIONS AND AN ACCEPTABLE METHOD FOR REMOVAL OF CONSTRUCTION MATERIALS AND WASTE. D11 CONTRACTOR SHALL COORDINATE ANY TEMPORARY DISRUPTION OF UTILITIES WITH BUILDING OWNER AND/OR TENANTS THAT MAY BE AFFECTED BY DISRUPTION. D12 CONTRACTOR SHALL PROVIDE TEMPORARY VENTILATION OF SPACE DURING DEMOLITION AND SHALL NOT ALLOW CONSTRUCTION DUST TO INFILTRATE ADJACENT TENANT SPACE, COMMON AREAS, OR RETURN AIR DUCTS OR PLENUMS. SEE ICRA DRAWINGS. D13 CONTRACTOR SHALL VERIFY (BY INDEPENDENT TEST IF NECESSARY) THAT NO PREVIOUSLY INSTALLED HAZARDOUS MATERIALS ARE PRESENT AT THE WORK SITE. IF HAZARDOUS MATERIALS ARE FOUND, REMOVAL SHALL BE MADE BY A QUALIFIED HAZARDOUS MATERIAL REMOVAL CONTRACTOR BEFORE DEMOLITION CONTINUES. DEMOLITION GENERAL NOTES (BOXED NOTE NUMBERS ARE KEYED TO PLAN) D14 DASHED LINES INDICATE ITEMS TO BE REMOVED OR SELECTIVELY DEMOLISHED. D15 SELECTIVELY DEMOLISH WALLS OR WALL SEGMENTS SHOWN WITH DASHED LINES. D16 N/A D17 N/A D19 PROVIDE OPENING IN EXISTING WALL FOR NEW DOOR. VERIFY SIZE OF FRAME AND ANCHORING REQUIREMENTS. SEE DIMENSION PLAN FOR EXACT LOCATION AND DOOR SCHEDULE FOR SIZE. SEE DETAIL FOR JAMB REINFORCEMENT AND LINTEL. D20 SEE MECHANICAL ENGINEERING DRAWINGS FOR DEMOLITION OF PLUMBING, ELECTRICAL, AND HVAC. D21 N/A D22 N/A D23 N/A D24 N/A D25 N/A D27 N/A D28 N/A D N A D30 SEE ELECTRICAL PLAN— FOR THE REMOVAL OR RELOCATION OF ELECTRICAL LIGHTING. D36 N/A D37 N/A D38 N/A WALL LEGEND 1= 1 A REMOVE DOORS AND DOOR FRAMES EXISTING INTERIOR WALL TO BE DEMOLISHED EXISTING EXTERIOR WALL TO BE DEMOLISHED EXISTING INTERIOR WALL TO REMAIN EXISTING EXTERIOR WALL TO REMAIN CAMPBELL +VAN DUSEN ARCH ITECTU RE INTERIOR DESIGN www.CVDstudio.com CAMPBELL + VAN DUSEN Design Studio, LLC. 255 South Orange Avenue Suite # 1240 Orlando, Florida 32801 Phone: 407.930.6016 FL. Lic. No. AR001 6053 ARCHITECT OF RECORD FRANK W. CAMPBELL AIA I'LLIC NO. AR0016053 COPY OF THIS PLAN IS NOT VALID UNLESS SIGNED, SEALED AND DATED BY THE ARCHITECT OF RECORD COPY OF THIS PLAN IS NOT VALID UNLESS SIGNED, SEALED AND DATED BY THE ENGINEER OF RECORD I LL_ _j 0 CL UJI r-4 u < c) (/) > LU LLJ I 0 + ae < U_j LU 0 C) U-i cl- 110 11q_ '0 Lx) 0:� EL < LU r_4 00 (y) r1_1 (y) CONSTRUCTION DOCUMENTS 03.24.2023 7m PRINCIPAL IN CHARGE F. CAMPBELL ... I ................................................................ PROJECT MANAGER M. TORRES .................................................................... ADVENT HEALTH WELL 65+ ZEPHYRHILLS 22-0328-01 DEMOLITION PLAN u It - 11 mKik, DEMO PLAN 1/411 = 1 1-011 5/8 GYP BOARD SOUND BATT INSULATIO 3 5/8" 25 GA MTL STUDS @ 16" 0. C. NEW WALL FURRING OVE R-\ i �7 INTERIOR OF EXISTING C U WALL SYSTEMS. I A ,,METAL CORNER BEAD ................ ............... ------------- EXISTING EXTERIOR WALL SYSTEMS EXISTING STOREFRONT SYSTEMS (_D-_f� FRAMING DETAIL - AT EXT. WINDOW JAMB 5/8 GYP BOARD SOUND BATT INSULATION 3 5/8" 25 GA MTL STUDS @ 16" 0. C. MET METAL CORNER BEAD LOW WALL SUPPOR BRACKET 1/8" STEEL METAL STUDS @ 16" O.C. BOTTOM CHANNE NNEL CONNECT WALL BRACKET SUPPORT TO FLOOR, AT EACH END OF WALL, W/ (2) 1/4" EXPANSION BOLT LOW WALL SUPPORT BRACKET (D­_4__�WATER WATER HEATER - SEE MEP DRAWINGS FOR REQUIREMENTS. 3/4" PLYWOOD SHELF 2"x4" P.T. WD FRAMEING _\___2"x4" P.T. WD BRACE WALL NOTE: SHELF MOUNTING HT. SHALL BE DETERMINED ON SITE. BASED ON REQUIRED SPACE FOR EQUIPMENT BELOW HEATER SHELF DETAIL FLOOR PLAN SYMBOLS I—# ROOM NUMBER SECTION WINDOW TYPE* DETAIL DOOR SYMBOL- SEE DOOR SCHEDULE DOOR CONTACT FINISHED CLEARANCE CARD READER m 71� f MINIMUM DIMENSION MAY BE _0 Fc.o. CASED OPENING* - v f COMBINED VERIFY DIMENSION WALL TYPE - SEE WALL LEGEND & SHEET AO.5 RADIUS OF CLEARANCE -AL ALIGNMENT LINE ITEM ABOVE OR FURNITURE/EQUIPMENT N.I. ITEM BELOW METAL CORNER BEAD-//' CENTERLINE POB POINT OF BEGINNING FOR LAYOUT INTERIOR & CABINET ELEVATIONS *NOTE: SEE SHEET A2.3 FOR DOOR & WINDOW TYPES j EXISTING EXTERIOR WINDOW Z EXISTING WINDOW MULLION FRAMING DETAIL - AT EXT. WINDOW *NOTE: SEE SHEET A2.3 FOR DOOR & WINDOW TYPES K ALE 1,I.T.S. MULL. A L E: � j. T.". TYPICAL AT ENDS OF LOW WALLS SI'AI.E: N.'.S. 10 9 8 7 6 5 4 3 2 1 4 Z. -A A - 71-4V" A -4 A 4"'; 4v' 4.� C'tF15_F1 4 A -A F F-5-B] 77 H C H Fi-cl C C H > W\Hl C ELEC. ROOM/ H FIRE RISER F ELLNESS SUITE 15B Fi _5B] 11i -5-B] -5 7__Hj F H H 4 Fi BI F7 7H F77H WELLNESS SUITE W LLNESS SUITE WELLNESS SUITE WELLNESS SUITE A 148 SF 5 1 6 7 1 8 CONSULT Room I r- - - - I A 116 :] I I I I < A A 1<1x " A A5.0 B [El I- 15A 144 SF FTH-1 145 SF F7-H] I 145 SIF F7_Hj 145 SF F7_Hj 106 SF CARE Fic� -i-cl A F7_H I L COORDINATORS C F1 I I B 15A F J-61 15A F1 I B] 15A 15 - - - 113 c Di 115 C F7 7H 124 SIF F-5B] A _7­H_ I F7__H1 A F77H A A I *H WELLNESS SUITE I F71H­1 C 3 CORRIDOR F _j A 7 H H 145 SF 1 11310 1 1 1 1 PRACTICE 15 I I ill h ']� I I ADMINISTRATOR F7­H1 <�> GLASS WALL F7 H-1 F7 H-1 12 SF L 125 A _J A5.0 114 R-F H 15A F1 _IA] F, C_� 0 c < C 1 11A _7H L Fi-cl -��>F7_H_] -cl Ituc I F7_H1 Fil F11-B] Lv m I F7 H_� I __j L 7H <�> F71j] F7_H I A F F F15-B] <E _H1 c - - - MED ROOM F7 H] STORAGE 2 C A 7H WELLNESS SUITE lool 0 CORRIDOR =Dic 77H HUDDLE F7 clj:�] I L E CORRIDOR I PROVIDER W 2 Fj�T] C) 124 IF07CAM 1 86 Fi T�] 0 1 116 SF 111 cl ROOM H 145 SF 1 1 673 SIF nlf�] 1­11­1 0 1111 m 11 cb iB 5A 15 F A5.0 G lu-a] ------ L If DOWNTIME COMPUTER I 15 III 1c ­i_P_ I PRINTER H L 144 SF H- Loh 1111 0 1111 10 1 Fi C-1 17- - 1 ___T_ I <�>F7­kl I - j H L U Ulu I A 7H I T I I C I 15A F, 7C <qll> F7_H I L jAB __1 7H] JIC. _w F7_H� lj:�] 15A F A F77H 0 4 F7 H 119 15C 4 1 1 1 ck� Fififl C) A F7 7H K A5.1 I A2.2 LU ' OLL. cl 71-1 F1 :0:1 _7H - 98 SF H 341 SIF 0 T I Fi-5-B] C) L CD WELLNESS SUITE r*1 0 GLASS WALLI j [[: F7_`H1 F L 7H <�>F7H c F <�> F7--H] UER < E E 124 A _TO1 ILIET Comm OOM I I AUTOCLAVE F7_H_1 H 1 H LAYOUT BY [P-1 L% I I I H I H 145 SIF 115 !11A 0 0 GLASS 0- 1 1A WAL AH AIT 11 1 521 F A DEPARTMENT 83 SF L — — — 1 92 SF 11 C ic lic L < > F7­H] F THI I C] .......... Fi -7 <�>F7 7H MURAL WAL -7— 15A CORRIDOR A 1 A 1 F7­H­1 -1 5�� F7_H 7H] _J 7 Iq 2� <��7H [Rfl Filc� A 11 B 1 1 F7_H I r3 L - - - USULT1113 A STORAGE1 A2.2 A2.2 F7_H I F, C-1 �44 H 106 F7_H_1 Fi0_A1 FECR F7_H_1 <F> 7H IF * F7__H� A 5-5-El TH-1 <�> 115 SF F H -A H [jlO�4CB 36 104B B \77 H IC 15E r__77 c F7 H-1 F7H_1 BREAK ROOM 05' TOIL 7 A I I 394 SF E A 52 -4 F1 Cl 7H A 1J� LOBBY 101 1 ED 11 11 11 1 510 SF MMUNITY PANIC BUTTON I -4 1 H H 394 SIF NHI Fi -1d H H L-- 4- L H H.C. AUTO OPERATOR H Fic-1 Fi-c-1 15D I H L 07 L I L -------------- j 4 -IF -214. 14 A H.C. AUTO 1' *4 4 A, 4, A 1 1j A , -A 4d 4 4 4 'd 47 OPERATOR'A 4 _4 14 1 'A' :_ - A . 4 .4. ' - , - ',, '-4- 1 '1- -, 4 ­ " I - - . " # Id " - "' � 'A' '�A 4 4 _'4 A 4 4 A - 4 _A, "4 4 4 4 - A , A A - ". 1 2", :MODIFY STOREFRONT TO ADD -- A, A- 4 �k A :4, 2. 4 A 44 A '4 A .4 _4- A A , .% -- - 4 , , ' ' - . 1 A-, -,.ENTRY DOOR 4 ' - —A� — '4� . A , ­1 - ­ , - - A A" 4 A 4 4 — — — — --- — — - — — — '4 A 44, 4 :4" ' __—_ ' __' — '4 — 4 - 1 '�4 A,. A A A- 1 4 , . 'I 4 4 , '4 4 44 4 : 4 4 A A A I . , - - , . I '5�' ' _4 4 A 46 . , - _ 1 4 , . - -4 'A� A! 4 4' A 4 z" , A 'A 4 - 4 2 A _4, -4 CONSTRUCTION PLAN 1/411 = 1 1-011 )RK PLAN NOTES: (BOXED NOTE NUMBERS ARE KEYED TO PLAN) IT IS THE CONTRACTOR'S RESPONSIBILITY TO CHECK WITH THE BUILDING OWNER WITH REFERENCE TO ROOF WARRANTIES AND/OR THE PRESCRIBED REQUIREMENTS FOR NEW ROOF PENETRATIONS. IN NO CASE SHOULD CONTRACTOR DO ANYTHING TO VOID ROOF WARRANTIES. CONTRACTOR IS REQUIRED TO HAVE BUILDING OWNER'S ROOFING CONTRACTOR MAKE, SUPERVISE, OR APPROVE ALL NEW ROOF PENETRATION. I A THE GENERAL CONTRACTOR AND ALL SUBCONTRACTORS SHALL MAKE REDLINE AS -BUILT NOTES ON THE DRAWINGS OF ALL DEVIATIONS FROM THE PLANS MADE DURING THE COURSE OF CONSTRUCTION. CONTRACTOR SHALL SUBMIT REDLINE NOTES AND DRAWINGS TO THE ARCHITECT AT THE COMPLETION OF CONSTRUCTION. IF NO DEVIATIONS OR CHANGES HAVE BEEN MADE DURING CONSTRUCTION, THE CONTRACTOR SHALL SUBMIT A LETTER TO THE ARCHITECT STATING THAT NO CHANGES WERE MADE. I B SUBCONTRACTORS SHALL GIVE TO CONTRACTOR PRODUCT LITERATURE FOR INSTALLED EQUIPMENT AND PRODUCTS THAT REQUIRE MAINTENANCE OF ANY TYPE (INCLUDING RELAMP OF LIGHT FIXTURES) AND ANY MAINTENANCE INSTRUCTIONS OR WARRANTIES AND THE CONTRACTOR SHALL OBTAIN PHONE NUMBERS AND ADDRESSES OF CONTACTS FOR REPAIR/MAINTENANCE AND BIND ALL OF THIS INFORMATION IN AN 8 1/2 X 11 NOTEBOOK. THIS MANUAL SHALL ALSO INCLUDE A COMPLETE LISTING OF IDENTIFICATION FOR ALL FINISH MATERIALS INCLUDING CEILING TILE, FLOOR TILE AND CARPET, AND PLASTIC LAMINATE AND PAI . A MAINTENANCE MANUAL TO OWNER AT COMPLETION OF PROJECT. 1 C THIS IS EQUIPMENT OR FURNITURE, NOT CONSTRUCTION. SEE EQUIPMENT/MEP DRAWINGS FOR PREPARATION AND COORDINATION REQUIRED BY CONTRACTOR. ALL SUBCONTRACTORS SHALL CONTACT AND COORDINATE WITH EQUIPMENT SUPPLIER FOR LAYOUT TEMPLATES AND VERIFICATION/REVIEW OF ROUGH -INS. 5K GRAB BARS @ HANDICAP TOILETS: 1 1/2" DIA., 1 1/2" CLEAR FROM WALL. 33"-36" ABOVE FINISHED FLOOR ANCHORED TO SUPPORT 250 LBS. ONE 42" LONG AT SIDE OF TOILET. ONE 36" LONG BEHIND TOILET. (SEE TOILET ROOM DETAILS FOR PLACEMENT.) 6A INFILL EXISTING WINDOW OPENING WITH 3 5/8" 25 GA METAL STUDS 24" O.C. W/ 5/8" DRYWALL FINISH. 6C PROVIDE 4" REINFORCED CONCRETE WALK PAD FROM EXTERIOR TO BACK OF CURB IF 6D CHASE WALLS: SEE PARTITION TYPES FOR WALL CONSTRUCTION. 6F PROVIDE 3 1/2" WIDE 12 GA. MTL BLOCKING STRIPS @ MOUNTING LOCATIONS OF ALL RAILINGS, CURTAIN TRACKS, AND OTHER BUILT-IN OR SURFACE -MOUNTED ACCESSORIES. AT CABINETS, PROVIDE 1 X6 FIRE -RETARDANT -TREATED WOOD BACKING. VERIFY SIZE AND LOCATION OF THI I PRODUCT/EQUIPMENT/CABINET INSTALLATION RECOMMENDATIONS OR NEEDS. 6K ALL WOOD FRAMING SHALL BE KILN -DRIED AND HAVE A MINIMUM FIBER STRESS 6Q CEILING: SEE SECTIONS AND DETAILS ON REFLECTED CEILING PLAN. DIMENSIONS AND ELEVATIONS SHOWN ON THESE SHEETS ARE FINISHED. ALL CEILING FRAMING TO BE @ 24" O.C. W/GYPSUM BOARD FINISH. 6R ALL WOOD IN CONTACT WITH CONCRETE OR MASONRY SHALL BE PRESSURE -TREATED OR HAVE AN APPROVED SEPARATING MATERIAL. 6V THE INTENT OF DESIGN IS TO ALIGN NEW WALLS WITH FRAMING AND FINISH OF EXISTING WALLS 6X PROVIDE 5/8" THICK, 24" X 24" FIRE RETARDANT TREATED PLYWOOD BEHIND GYP. BOARD FOR WALL HUNG TVs. CENTER TVs ON PLYWOOD. 7A SEALANT: APPLY SEALANT AT JOINING OF ALL DISSIMILAR MATERIALS EXPOSED TO WEATHER AND AT GAPS EXPOSED TO VIEW. 7B SEALANT: PROVIDE A FULL BED OF SEALANT AT WINDOW AND DOOR FRAMES (INCLUDING THRESHOLD) AND A CONTINUOUS BEAD AT PERIMETER OF EXTERIOR AND INTERIOR WINDOWS AND DOORS. 7H SOUND BATT INSULATION IN INTERIOR WALLS AS INDICATED. SEE WALL LEGEND, I 8A ALL GLASS IN DOORS OR SIDELIGHTS SHALL BE TEMPERED AND SHALL COMPLY WITH THE FLORIDA BUILDING CODE 2017, SECTION 2406, SAFETY GLAZING. GLASS IN RATED DOORS SHALL COMPLY W/RATING OF DOOR. 8B ALL DOOR HARDWARE SHALL MEET CURRENT ADA AND FLORIDA ACCESSIBILITY CODES. 8C ALL WINDOW AND DOOR FRAMES SHALL BE SECURED TO SURROUNDING WALL PER MANUFACTURER RECOMMENDATION FOR WIND ZONE. 8D EXISTING DOOR TO REMAIN. DOOR TO BE LOCKED & HARDWARE TO BE REMOVED AND OPENINGS CAPPED. CONTINUOUSLY SEAL DOOR USING BASF MASTERSEAL NP 100, INSTALL PER MFG. RECOMMENDATIONS. COLOR TO MATCH DOOR AS CLOSE AS POSSIBLE. 8F PROVIDE WINDOW SILLS (MATCH EXISTING BUILDING STANDARD) @ INTERIOR OF EACH WINDOW UNIT NOTED. 9B 1/2" GYP BOARD MAY BE USED ON SIDES AND BOTTOM OF DROPPED SOFFITS UNLESS NOTED OTHERWISE. 9C AT ALL CHANGES IN FLOOR MATERIAL, PROVIDE APPROPRIATE ADA-COMPLIANT TRANSITION STRIP. IF AT DOOR, LOCATE DIRECTLY UNDER DOOR. 9E WHEN NOT INDICATED ON PLANS, VERIFY COLOR AND PATTERN SELECTIONS WITH OWNER. 9K FILL IN DRYWALL AT DEMOLISHED WALL LOCATIONS. TAPE AND FINISH NEW DRYWALL TO BE FLUSH WITH ADJACENT REMAINING WALL. 9Y LEAVE 1/2" GAP BETWEEN FINISH FLOOR AND BOTTOM EDGE OF GYPSUM BOARD. 9Z PREPARE ALL WALLS FOR PAINT, TO A GA 216 LEVEL 4 DRYWALL FINISH. 9N ALL TOILETS: USE 5/9'MOISTURE RESISTANT GYPSUM BOARD ON BATHROOM SIDE OF ALL WALLS BEHIND A TOILET AND/OR LAVATORY. 9Q ALL NEW CARPET & WALLPAPER SHALL BE ANTIMICROBIAL TREATED FROM THE 10A PROVIDE AND INSTALL TYPE 2A 10 BC FIRE EXTINGUISHER (S) WHERE SHOWN ON PLAN. THE TOP OF FIRE EXTINGUISHER SHALL NOT BE MORE THAN 5 FT. ABOVE THE FLOOR (3 1/2 FT. IF FIRE EXTINGUISHER'S GROSS WEIGHT IS MORE THAN 40 LBS) AND BOTTOM NOT LESS THAN 4 INCHES ABOVE THE FLOOR. 10B RAISED/BRAILLED CHARACTERS & PRACTICAL SYMBOL SIGNS LETTERS AND NUMERALS SHALL BE RAISED 1/32 IN, UPPER CASE, SANS SERIF OR SIMPLE SERIF TYPE, AND SHALL BE ACCOMPLISHED WITH GRADE 2 BRAILLE. RAISED CHARACTERS SHALL BE AT LEAST 5/8 IN (16 MM) HIGH, BUT NO HIGHER THAN 2 IN (50 MM). PICTOGRAMS SHALL BE ACCOMPLISHED BY THE EQUIVALENT VERBAL DESCRIPTION PLACED DIRECTLY BELOW THE PICTOGRAM. THE BORDER DIMENSION OF THE PICTOGRAM SHALL BE 6 IN (152 MM) MINIMUM IN HEIGHT. MOUNTING LOCATIONS AND HEIGHT SIGNS SHALL BE INSTALLED ON THE WALL ADJACENT TO THE LATCH SIDE OF THE TOILET RM DOORS. MOUNTING HEIGHT SHALL BE 60 IN. (1525 MM) ABOVE FINISH FLOOR TO THE CENTERLINE OF THE SIGN. (IF LATCHSIDE UNAVAILABLE USE NEAREST ADJACENT WALL FOR SIGN). OWNER TO PROVIDE. 10C CONTRACTOR TO INSTALL OWNER PROVIDED AED SEMI -RECESSED CABINET 11A CABINETS AND CASE WORK: SEE ALL DRAWINGS FOR CABINET SIZES, FINISHES, HARDWARE AND MATERIALS SPECIFICATIONS. THE CONTRACTOR SHALL SUBMIT SHOP DRAWINGS FOR APPROVAL PRIOR TO FABRICATION. 11B CABINETS AND CASE WORK PROVIDED BY OWNER, CONTRACTOR TO COORDINATE INSTALLATION W/ OWNER. 11C AT ALL WALLS RECEIVING CABINETS AND CASE WORK, PROVIDE 4'x8'xl /2" FIRE RESISTANT PLYWOOD BACKING ON ALL 4 WALLS. AS REQUIRED. 11D TELCOM CLOSET: PROVIDE AND MOUNT (1) SHEET OF 4'X 8'X 1/2" FIRE -RETARDANT TREATED BC PLYWOOD WITH TOP AT 8'-0" AFF. AT ALL WALLS. 12A PROVIDE NEW WINDOW TREATMENTS, ROLLER SHADE SYSTEM. SEE FINISH LEGEND. 12B PROVIDE CAP SHEET FILM SOLYX SXWF-WB WHITE BLACK OPAQUE AT EXISTING WINDOW INTERIOR 15A CONTRACTOR TO INSTALL OWNER PROVIDED SOAP DISPENSERS AT EACH SINK AND LAVATORY. 15B CONTRACTOR TO INSTALL OWNER PROVIDED DIAGNOSTIC BOARDS IN ALL WELLNESS SUITES. CONTRACTOR TO INSTALL DIAGNOSTIC WALL BOARD BRACKET. SEE DIET 2/AO.5 FOR DIAGNOSTIC BOARD NICHE. 15C CONTRACTOR TO INSTALL OWNER PROVIDED SHARP CONTAINERS IN ALL WELLNESS SUITES, LAB AND MED ROOM 15D CONTRACTOR TO INSTALL OWNER PROVIDED PAPER TOWEL DISPENSERS AT BREAK ROOM AND COMMUNITY ROOM 15E CONTRACTOR TO INSTALL OWNER PROVIDED REFRIGERATOR LINES FOR ICE MAKERS IN BREAK ROOM 15F CLOSE AND LOCK EXISTING EXTERIOR DOOR. REMOVE LEVER HARDWARE AND CAP. CAULK WITH EXTERIOR RATED BUTYL CAULK. PROVIDE CONTINIOUS BEAD ALL SIDES AND THRESHOLD INTERIOR AND EXTERIOR. CAMPBELL +VAN DUSEN ARCH ITECTU RE INTERIOR DESIGN www.CVDstudio.com CAMPBELL + VAN DUSEN Design Studio, LLC. 255 South Orange Avenue Suite # 1240 Orlando, Florida 32801 Phone: 407.930.6016 FL. Lic. No. AROO 16053 ARCHITECT OF RECORD FRANK W. CAMPBELL AIA FL LIC NO. AR001 6053 COPY OF THIS PLAN IS NOT VALID UNLESS SIGNED, SEALED AND DATED BY THE ARCHITECT OF RECORD COPY OF THIS PLAN IS NOT VALID UNLESS SIGNED, SEALED AND DATED BY THE ENGINEER OF RECORD _j LL_ c/i _j _j 0 F_ EL CL -T- LU 11-4 < ci V) (/I) > LU LLj _j + LO '0 < UJ ) LJLJ > 0 C) LLJ -'0 Lf) a- < 3�: r-4 00 co f-, Cy) CONSTRUCTION DOCUMENTS 03.24.2023 PRINCIPAL IN CHARGE F. CAMPBELL .................................................................... PROJECT MANAGER MJO.RRES ....................................................... 14 ADVENT HEALTH WELL 65+ ZEPHYRHILLS 22-0328-01 CONSTRUCTION PLAN A2.0 �1161661� 1 - 6"'MA .311M I"Ut ",U "L- � 6 1 d­A­1_ NOTE: ALL PLAN DIMENSIONS ARE TO FACE OF G.W.B. AS ELOOR PLAN SYMBOLS SHOWN BELOW, UNLESS SPECIFICALLY NOTED OTHERWISE. F_#__1 ROOM NUMBER SECTION WINDOW TYPE* ED DOOR SYMBOL- SEE DOOR SCHEDULE 5/8" GYP WALL BOARD 6 X 6 WELDED WIRE MESH IF MORE THAN 24'WIDE ISTI NG SLAB A MAN 14� WIDIIi DETAIL DOOR CONTACT FINISHED CLEARANCE —ACTUAL L 4 1/2" MAX (2) 3-5/8" METAL STUDS TIGHT TO ADJACENT WALL OR CORNER CHANNEL ANCHOR HOLLOW METAL FRAME TO STUD DOOR OPENING TO BEGIN A MAXIMUM OF 4 1/2" FROM ADJACENT STUD LINE DIMENSIONS ARE TO FACE OF G.W.B. U.N.O. GYP WALL BOARD-­�� METAL RUNNERS TOP & BOTT 5/8" MTL STUDS U.N.O. J_ 4" CONCRETE INFILL 'TEx -7 < `0 INSURE STABILITY AT SLAB CONNECTION VAPOR BARRIER —APPLY NEW TERMITE TREATMENT AT ALL AREAS THAT SOIL IS DISTURBED. COMPACTED SOIL CARD READER MINIMUM DIMENSION MAY BE Fc.o. CASED OPENING* VERIFY DIMENSION COMBINED WALL TYPE - SEE WALL LEGEND & SHEET AO.5 �R RADIUS OF CLEARANCE AL ALIGNMENT LINE ITEM ABOVE OR FURNITURE/EQUIPMENT N.I.0 ITEM BELOW F N C_ TERLINE POB POINT OF BEGINNING FOR LAYOUT INTERIOR & CABINET ELEVATIONS *NOTE: SEE SHEET A2.3 FOR DOOR & WINDOW TYPES (1) SIMPSON STRONG -TIE TITEN HD 1" X 4" (MIN.) 4 @ 16" O.C. 2" INTO EXISTING SLAB AND EXTEND 2" INTO NEW DOOR FRAMING DETAIL - TYPICAL 'D- LAYOUT DIMENSION DETAIL (D_4� SLAB INFILL DETAIL *NOTE: SEE SHEET A2.3 FOR DOOR & WINDOW TYPES HINGE SIDE (�d_) DOORS SHOWN SCALE: N.T.S. HORIZONTAL SEC TION SCALE- N.T.S. SIC: 3" - 1'-0" IN CORNER OF ROOM rl'� DIMENSION PLAN 1/411 = 1 1-011 PLAN NOTES: (BOXED NOTE NUMBERS ARE KEYED TO PLAN) IT IS THE CONTRACTOR'S RESPONSIBILITY TO CHECK WITH THE BUILDING OWNER WITH REFERENCE TO ROOF WARRANTIES AND/OR THE PRESCRIBED REQUIREMENTS FOR NEW ROOF PENETRATIONS. IN NO CASE SHOULD CONTRACTOR DO ANYTHING TO VOID ROOF WARRANTIES. CONTRACTOR IS REQUIRED TO HAVE BUILDING OWNER'S ROOFING CONTRACTOR MAKE, SUPERVISE, OR APPROVE ALL NEW ROOF PENETRATION. I A THE GENERAL CONTRACTOR AND ALL SUBCONTRACTORS SHALL MAKE REDLINE AS -BUILT NOTES ON THE DRAWINGS OF ALL DEVIATIONS FROM THE PLANS MADE DURING THE COURSE OF CONSTRUCTION. CONTRACTOR SHALL SUBMIT REDLINE NOTES AND DRAWINGS TO THE ARCHITECT AT THE COMPLETION OF CONSTRUCTION. IF NO DEVIATIONS OR CHANGES HAVE BEEN MADE DURING CONSTRUCTION, THE CONTRACTOR SHALL SUBMIT A LETTER TO THE ARCHITECT STATING THAT NO CHANGES WERE MADE. I B SUBCONTRACTORS SHALL GIVE TO CONTRACTOR PRODUCT LITERATURE FOR INSTALLED EQUIPMENT AND PRODUCTS THAT REQUIRE MAINTENANCE OF ANY TYPE (INCLUDING RELAMP OF LIGHT FIXTURES) AND ANY MAINTENANCE INSTRUCTIONS OR WARRANTIES AND THE CONTRACTOR SHALL OBTAIN PHONE NUMBERS AND ADDRESSES OF CONTACTS FOR REPAIR/MAINTENANCE AND BIND ALL OF THIS INFORMATION IN AN 8 1/2 X 11 NOTEBOOK. THIS MANUAL SHALL ALSO INCLUDE A COMPLETE LISTING OF IDENTIFICATION FOR ALL FINISH MATERIALS INCLUDING CEILING TILE, FLOOR TILE AND CARPET, AND PLASTIC LAMINATE AND PAINT. CONTRACTOR SHALL DELIVER THIS PROJECT MAINTENANCE MANUAL TO OWNER AT COMPLETION OF PROJECT. I C THIS IS EQUIPMENT OR FURNITURE, NOT CONSTRUCTION. SEE EQUIPMENT/MEP DRAWINGS FOR PREPARATION AND COORDINATION REQUIRED BY CONTRACTOR. ALL SUBCONTRACTORS SHALL CONTACT AND COORDINATE WITH EQUIPMENT SUPPLIER FOR LAYOUT TEMPLATES AND VERIFICATION/REVIEW OF ROUGH -INS. 5K GRAB BARS @ HANDICAP TOILETS: 1 1/2" DIA., 1 1/2" CLEAR FROM WALL. 33"-36" ABOVE FINISHED FLOOR ANCHORED TO SUPPORT 250 LBS. ONE 42" LONG AT SIDE OF TOILET. ONE 36" LONG BEHIND TOILET. (SEE TOILET ROOM DETAILS FOR PLACEMENT.) 6A INFILL EXISTING WINDOW OPENING WITH 3 5/9'25 GA METAL STUDS 24" O.C. W/ 5/8" DRYWALL FINISH. 6C PROVIDE 4" REINFORCED CONCRETE WALK PAD FROM EXTERIOR TO BACK OF CURB IF NOT ALREADY PROVIDED. 6D CHASE WALLS: SEE PARTITION TYPES FOR WALL CONSTRUCTION. 6F PROVIDE 3 1/2" WIDE 12 GA. MTL BLOCKING STRIPS @ MOUNTING LOCATIONS OF ALL RAILINGS, CURTAIN TRACKS, AND OTHER BUILT-IN OR SURFACE -MOUNTED ACCESSORIES. AT CABINETS, PROVIDE 1X6 FIRE-RETA RDA NT-TREATED WOOD BACKING. VERIFY SIZE AND LOCATION OF THIS BLOCKING WITH PROD U CT/EQU IPMENT/CA BIN ET INSTALLATION RECOMMENDATIONS OR NEEDS. 6K ALL WOOD FRAMING SHALL BE KILN -DRIED AND HAVE A MINIMUM FIBER STRESS OF 1200 PSI. 6Q CEILING: SEE SECTIONS AND DETAILS ON REFLECTED CEILING PLAN. DIMENSIONS AND ELEVATIONS SHOWN ON THESE SHEETS ARE FINISHED. ALL CEILING FRAMING TO BE @ 24" O.C. W/GYPSUM BOARD FINISH. 6R ALL WOOD IN CONTACT WITH CONCRETE OR MASONRY SHALL BE PRESSURE -TREATED OR HAVE AN APPROVED SEPARATING MATERIAL. 6V THE INTENT OF DESIGN IS TO ALIGN NEW WALLS WITH FRAMING AND FINISH OF EXISTING WALLS 6X PROVIDE 5/9'THICK, 24" X 24" FIRE RETARDANT TREATED PLYWOOD BEHIND GYP. BOARD FOR WALL HUNG TVs. CENTER TVs ON PLYWOOD. 7A SEALANT: APPLY SEALANT AT JOINING OF ALL DISSIMILAR MATERIALS EXPOSED TO WEATHER AND AT GAPS EXPOSED TO VIEW. 7B SEALANT: PROVIDE A FULL BED OF SEALANT AT WINDOW AND DOOR FRAMES (INCLUDING THRESHOLD) AND A CONTINUOUS BEAD AT PERIMETER OF EXTERIOR AND INTERIOR WINDOWS AND DOORS. 7H SOUND BATT INSULATION IN INTERIOR WALLS AS INDICATED. SEE WALL LEGEND, THIS SHEET, AND WALL TYPES, SHEET AO.4 AND AO.5 8A ALL GLASS IN DOORS OR SIDELIGHTS SHALL BE TEMPERED AND SHALL COMPLY WITH THE FLORIDA BUILDING CODE 2017, SECTION 2406, SAFETY GLAZING. GLASS IN RATED DOORS SHALL COMPLY W/RATING OF DOOR. 8B ALL DOOR HARDWARE SHALL MEET CURRENT ADA AND FLORIDA ACCESSIBILITY CODES. 8C ALL WINDOW AND DOOR FRAMES SHALL BE SECURED TO SURROUNDING WALL PER MANUFACTURER RECOMMENDATION FOR WIND ZONE. 8D EXISTING DOOR TO REMAIN. DOOR TO BE LOCKED & HARDWARE TO BE REMOVED AND OPENINGS CAPPED. CONTINUOUSLY SEAL DOOR USING BASF MASTERSEAL NP 100, INSTALL PER MFG. RECOMMENDATIONS. COLOR TO MATCH DOOR AS CLOSE AS POSSIBLE. 8F PROVIDE WINDOW SILLS (MATCH EXISTING BUILDING STANDARD) @ INTERIOR OF EACH WINDOW UNIT NOTED. 9B 1/2" GYP BOARD MAY BE USED ON SIDES AND BOTTOM OF DROPPED SOFFITS UNLESS NOTED OTHERWISE. 9C AT ALL CHANGES IN FLOOR MATERIAL, PROVIDE APPROPRIATE ADA-COMPLIANT TRANSITION STRIP. IF AT DOOR, LOCATE DIRECTLY UNDER DOOR. 9E WHEN NOT INDICATED ON PLANS, VERIFY COLOR AND PATTERN SELECTIONS WITH OWNER. 9K FILL IN DRYWALL AT DEMOLISHED WALL LOCATIONS. TAPE AND FINISH NEW DRYWALL TO BE FLUSH WITH ADJACENT REMAINING WALL. 9Y LEAVE 1/2" GAP BETWEEN FINISH FLOOR AND BOTTOM EDGE OF GYPSUM BOARD. 9z PREPARE ALL WALLS FOR PAINT, TO A GA 216 LEVEL 4 DRYWALL FINISH. 9N ALL TOILETS: USE 5/8" MOISTURE RESISTANT GYPSUM BOARD ON BATHROOM SIDE OF ALL WALLS BEHIND A TOILET AND/OR LAVATORY. 9Q ALL NEW CARPET & WALLPAPER SHALL BE ANTIMICROBIAL TREATED FROM THE FACTORY. I OA PROVIDE AND INSTALL TYPE 2A 10 BC FIRE EXTINGUISHER (S) WHERE SHOWN ON PLAN. THE TOP OF FIRE EXTINGUISHER SHALL NOT BE MORE THAN 5 FT. ABOVE THE FLOOR (3 1/2 FT. IF FIRE EXTINGUISHER's GROSS WEIGHT IS MORE THAN 40 LBS) AND BOTTOM NOT LESS THAN 4 INCHES ABOVE THE FLOOR. IOB RAISED/BRAILLED CHARACTERS & PRACTICAL SYMBOL SIGNS LETTERS AND NUMERALS SHALL BE RAISED 1/32 IN, UPPER CASE, SANS SERIF OR SIMPLE SERIF TYPE, AND SHALL BE ACCOMPLISHED WITH GRADE 2 BRAILLE. RAISED CHARACTERS SHALL BE AT LEAST 5/8 IN (16 MM) HIGH, BUT NO HIGHER THAN 2 IN (50 MM). PICTOGRAMS SHALL BE ACCOMPLISHED BY THE EQUIVALENT VERBAL DESCRIPTION PLACED DIRECTLY BELOW THE PICTOGRAM. THE BORDER DIMENSION OF THE PICTOGRAM SHALL BE 6 IN (152 MM) MINIMUM IN HEIGHT. MOUNTING LOCATIONS AND HEIGHT SIGNS SHALL BE INSTALLED ON THE WALL ADJACENT TO THE LATCH SIDE OF THE TOILET RM DOORS. MOUNTING HEIGHT SHALL BE 60 IN. (1525 MM) ABOVE FINISH FLOOR TO THE CENTERLINE OF THE SIGN. (IF LATCHSIDE UNAVAILABLE USE NEAREST ADJACENT WALL FOR SIGN). OWNER TO PROVIDE. 10C CONTRACTOR TO INSTALL OWNER PROVIDED AED SEMI -RECESSED CABINET 11A CABINETS AND CASE WORK: SEE ALL DRAWINGS FOR CABINET SIZES, FINISHES, HARDWARE AND MATERIALS SPECIFICATIONS. THE CONTRACTOR SHALL SUBMIT SHOP DRAWINGS FOR APPROVAL PRIOR TO FABRICATION. 11B CABINETS AND CASE WORK PROVIDED BY OWNER, CONTRACTOR TO COORDINATE INSTALLATION W/ OWNER. 1IC AT ALL WALLS RECEIVING CABINETS AND CASE WORK, PROVIDE 4'x8'xl /2" FIRE RESISTANT PLYWOOD BACKING ON ALL 4 WALLS. AS REQUIRED. 11D TELCOM CLOSET: PROVIDE AND MOUNT (1) SHEET OF WX 8'X 1/2" FIRE -RETARDANT TREATED BC PLYWOOD WITH TOP AT 8'-0" AFF. AT ALL WALLS. 12A PROVIDE NEW WINDOW TREATMENTS, ROLLER SHADE SYSTEM. SEE FINISH LEGEND. 12B PROVIDE CAP SHEET FILM SOLYX SXWF-WB WHITE BLACK OPAQUE AT EXISTING WINDOW INTERIOR 15A CONTRACTOR TO INSTALL OWNER PROVIDED SOAP DISPENSERS AT EACH SINK AND LAVATORY. 15B CONTRACTOR TO INSTALL OWNER PROVIDED DIAGNOSTIC BOARDS IN ALL WELLNESS SUITES. CONTRACTOR TO INSTALL DIAGNOSTIC WALL BOARD BRACKET. SEE DET 2/AO.5 FOR DIAGNOSTIC BOARD NICHE. 15C CONTRACTOR TO INSTALL OWNER PROVIDED SHARP CONTAINERS IN ALL WELLNESS SUITES, LAB AND MED ROOM 15D CONTRACTOR TO INSTALL OWNER PROVIDED PAPER TOWEL DISPENSERS AT BREAK ROOM AND COMMUNITY ROOM 15E CONTRACTOR TO INSTALL OWNER PROVIDED REFRIGERATOR LINES FOR ICE MAKERS IN BREAK ROOM 15F CLOSE AND LOCK EXISTING EXTERIOR DOOR. REMOVE LEVER HARDWARE AND CAP. CAULK WITH EXTERIOR RATED BUTYL CAULK. PROVIDE CONTINIOUS BEAD ALL SIDES AND THRESHOLD INTERIOR AND EXTERIOR. CAMPBELL + VAN DUSEN ARCHITECTURE INTERIOR DESIGN www.CVDstudio.com CAMPBELL + VAN DUSEN Design Studio, LLC. 255 South Orange Avenue Suite # 1240 Orlando, Florida 32801 Phone: 407.930.6016 FL. Lic. No. AR001 6053 A, ARCHITECT OF RECORD FRANK W. CAMPBELL AIA FLLIC NO. AR0016053 COPY OF THIS PLAN IS NOT VALID UNLESS SIGNED, SEALED AND DATED BY THE ARCHITECT OF RECORD COPY OF THIS PLAN IS NOT VALID UNLESS SIGNED, SEALED AND DATED BY THE ENGINEER OF RECORD _j LL_ CL LU c) r) Uj LLJ + LO LU LLj 0 n LU NO 'q- '0 Lo 0:� 0- LU r_4 00 (y) r1_1 (y) CONSTRUCTION DOCUMENTS 03.24.2023 DESCRIPTION PRINCIPAL IN CHARGE F. CAMPBELL .................................................................... PROJECT MANAGER M. TORRES .................................................................... ADVENT HEALTH WELL 65+ ZEPHYRHILLS 22-0328-01 DIMENSION PLAN A2.1 m a 0 a wu ig I rco 1 wom I 1/211 = 11-011 9'-0" A. F.F. ErDAVI FINISHED FLOORrk,, �4j TYP. ELEVATION 0 TOILET 112" = 11-011 TYP. SECTION @ TOILET (A-3 k \\��2.2 1/211 = 1 1-011 I TYP. ELEVATION @ TOILET 1/211 = 1 1-011 V-101" A. F.F. d) \-V FINISHED FLOORm \4--, (D TOILET SYMBOL LEGEND ALL R/R ACCESSORIES SHALL BE BY BOBRICK WASHROOM EQUIPMENT OR EQUAL, U.N.O., AND SHALL BE STAINLESS STEEL FINISH. MOUNT ALL FIXrURES PER ADAAG REQUIREMENTS. A. KOHLER K-3493-0 HIGHLINE CLASSIC COMFORT HEIGHT TWO-PIECE ELONGATED 1.6 GPF TOILET WHITE WITH KOHLER K-4731 -GC-0 STRONGHOLD QUIET CLOSE ELONGATED TOILET SEAT IN WHITE * FLUSH LEVER TO BE ON THE APPROACH SIDE B. KOHLER K-20000-0 CAXTON RECTANGLE UNDER -MOUNT SINK, WHITE C. AMERICAN STANDARD 7502.170.002 DOUBLE HANDLE CENTERSET GOOSENECK BATHROOM FAUCET D. BOBRICK B-6806.99 X 36 ADA 36" GRAB BAR WITH PEENED GRIPPING SURFACE E. BOBRICK B-6806.99 X 42 ADA 42" GRAB BAR WITH PEENED GRIPPING SURFACE F. BOBRICK B-2888 CLASSIC SERIES SURFACE -MOUNTED MULTI -ROLL TOILET TISSUE DISPENSER G. ECOLAB NEXA 9202-1188 CLASSIC TOUCH FREE SOAP DISPENSER - OWNER FURNISHED, CONTRACTOR INSTALLED. H. EBUN BDI 114 WALL MOUNT PAPER TOWEL DISPENSER, BAMBOO ORIGINAL 1. BOBRICK B-165 2436 CHANNEL FRAME MIRROR: 24"X36" J. BOBRICK B-682 SURFACE MOUNTED HAT AND COAT HOOK. MOUNT CENTERED ON DOOR INSIDE RESTROOM STALLS PER ADAAG REQUIREMENTS r, , - n­ Lq TOILET 105 1/211 = 1 1-011 TOILET 120 1/201 = 1 1-011 TOILET 103 1/211 = 1 1-011 92� A�m 3- 7" 1'- 3" V - 7" MIN. L _j L TOILET 130 1/2#1 = 1 1-011 I ,0 00 - I I CV) - L10 H.C.-ACCESSIBLE BATHROOM 60" X 56" CLEAR FLOOR SPACE FOR WATER CLOSET (SIDE APPROACH) 30" X 48" CLEAR FLOOR SPACE FOR LAVATORY 5--a'DIAMETER TURN -AROUND SPACE 30" X 48" ADA TOILET MANEUVERING CLEARANCE TYPICAL H.C. TOILET ELEVATIONS VIRROR 2 4 " X 3 6 VIRROR — NOT TILTED Q0 12 42" VIN 36" MIN 17" MIN MAX 10d, x 8" bAN I < MIN MIN A�' x < FLUSH Q0 0 PAPER 00 z :2 HANDLE 1 -t -m - CN COVER 1% 'SHALL BE OR ON OPEN INSULATE SIDE OF W.C. SIDE ELEVATION TANK (L V LAV SIDE ELUVATION FRONT ELIN TION SCALE'1/2'= F-G' SCALE: 1/2'= Y-a' SCALE: 1/2'= V-Y' GRAB BAR MOUNTING DETAIL GYPSUM WALL BOARD METAL STUDS GRAB BAR 1 1/2"0 1 1/2" CLEARANCE FROM WALL ANCHOR PLATE 12 GA. STEEL ALT: USE 2X6 WOOD BETWEEN STUDS 0 TYPICAL HCAILO EWC MOUNTING DETAIL CLEAR FLOOR 8 SPACE MIN. 2 op 48"X30" 48" WN CENTERED ON LOWER 00 (HANDICAP )I oc ACCESSIBLE) u z DRINKING FOUNTAIN 7-_ co 0 SPOUT HEIGHT ELEVATION CLEAR FLOOR SPACE KNEE CLEARANCE AND SPOUT HEIGHT ELEVATION (HC_j� HC. MOUNTING DETAIL SCALE: N.T-S. CAMPBELL + VAN DUSEN ARCHITECTURE INTERIOR DESIGN www.CVDstudio.com CAMPBELL + VAN DUSEN Design Studio, LLC. 255 South Orange Avenue Suite # 1240 Orlando, Florida 32801 Phone: 407.930.6016 FL. Lic. No. AR001 6053 ARCHITECT OF RECORD FRANK W. CAMPBELL AIA I'LLIC NO. AR0016053 COPY OF THIS PLAN IS NOT VALID UNLESS SIGNED, SEALED AND DATED BY THE ARCHITECT OF RECORD COPY OF THIS PLAN IS NOT VALID UNLESS SIGNED, SEALED AND DATED BY THE ENGINEER OF RECORD __j LL_ 0 CL LU < 0 V) > LU LLJ __j Q + ZZO < > 0 C) LU '0 -,0 Lo Q::� CL LU r_4 00 cy) 1`1_1 cy) CONSTRUCTION DOCUMENTS 03.24.2023 DESCRIPTION PRINCIPAL IN CHARGE F. CAMPBELL .................................................................... PROJECT MANAGER M. TORRES .................................................................... ADVENT HEALTH WELL 65+ ZEPHYRHILLS 22-0328-01 DETAILS A2.2 INTERIOR WOOD S.C. FLUSH LU LU ZD 0 Q LU LU U U) < **IN AS SCHEDUL�D EQ EQ �S SCHEDULE6 / AS SCHEDULED 0.1 -A-] F F 7C INTERIOR DOOR TYPES INTERIOR P.R. WOOD S.C. FLUSH INTERIOR WOOD P.C. BARN 1 /4" 1 1-011 EXTERIOR EXISTING EXTERIOR STOREFRONT DOORS TO REMAIN x LU EQ EQ .4 00, AS SCHEDULED EXTERIOR DOOR TYPES 1/411 11-011 EXTERIOR EXTERIOR NEW HOLLOW METAL EXTERIOR STOREFRONT FLUSH DOOR. MATCH DOOR TO MATCH EXISTING BASE BLDG DOOR TYPE XI FOR DOORS FOR MFG/STILE/GLAZING/ MFG/STILE/FINISH/HARD FINISH WARE LU __j LU 57< LU U V) V) < AS SCHEDULED AS SCHEDULED F­X2 FG 6'- 1" �O 00-1 3'- 3" 2'- 10" 0 DOORAS Co �)P' SCHED. WINDOW INTERIOR INTERIOR PR. B.O.D. KAWNEER STOREFRONT B.O.D. KAWNEER STOREFRONT INTERIOR ALUMINUM/GLASS INTERIOR ALUMINUM/GLASS DOOR SYSTEMS 5" STILES, 5" DOOR SYSTEMS 5" STILES, 5" TOP RAIL, 10" BOTTOM RAIL TOP RAIL, I (XBOTTOM RAIL 60" VERTICAL LADDER PULLS 60" VERTICAL LADDER PULLS BACK-TO-BACK BACK-TO-BACK U-1 LU z:) 0 I 1 0 / LU M C) C/) V) < EQ EQ "IN AS SCHEDUL�D AS SCHEDULED F D F-E 15- 0" 2'- 7" 2'- 7" 2'- 7" 6'- 2" 1.-6, ;01 WINDOW 24'- 0" 3- 8" 4'- 7" 3'- 2" 1'- 1" 3'- 6" 3'- 5" 3- 5" 70, 0" 4'- 5" 4'- 5" (�)WINDOW 29'- 0" 4'- 0" 3' - 2" 4'- 4" I.J. 4'- 5" 4'- 5" 0 DOORAS SCHED. WINDOW WINDOW ELEVATIONS 1 /411 1 1-011 H.M. FRAME 0 - 1 3' - 0" lei FOR DOOR TYPE A & G 1/411 1 1-011 H.M. FRAME Z) _V FOR DOOR TYPE B of 3- 11" of 3- 11" 3- 11" top Of MA I W6 a "07T WINDOW DOOR HARDWARE Door Hardware Set No. I Each pair to have: I Each DORMAKABA ED100 LOW ENERGY POWER OPERATOR 3 Each MS SEDCO 59 SERIES - HSS CLEARPATH RADIO CONTROL SWITCHES Note: E)dsfing Opening - Field inspect eAsting hardware. Door Hardware Set No. 2 Each door to have: 3 Each Hinges B 1331 4.5 x 4.5 626 Cal -Royal I Each Privacy SL20 626 Cal -Royal Each ADA Closer N900PBFDA x SPAS900 689 Cal -Royal Each KickPlate BKICK1034 630 Cal -Royal 3 Each Silencers DSM21 Rubber Cal -Royal Door Hardware Set No. 3 Each door to have: I System Barn Door - Medical Slide 628 Serenity I Each Lockset Office SM-203 Pull B213 24' 630 Serenity Note: Key/Lock side inside Broker Room Door Hardware Set No. 4 Each door to have: I System Bami Door - Medical Slide 628 Serenity I Each PassageSM-201 PuII82B2,f' 630 Serenity Door Hardware Set No. 5 Each pair to have: 6 Each Hinges BB31 4.5 x 4.5 NRP 626 Cal -Royal Pair Flushbolt MF6341 626 Cal -Royal Each Classroom SL03 626 Cal -Royal I Each Wall Stop WB26 689 Cal -Royal 2 Each Silencers DSM21 Rubber Cal -Royal Door Hardware Set No. 6 Each door to have: 3 Each Hinges BB31 4.5 x 4.5 626 Cal -Royal I Each Storage SL05 626 Cal -Royal I Each OH Stop HD664S 630 Cal -Royal 3 Each Silencers DSM21 Rubber Cal -Royal Door Hardware Set No. 7 Each door to have; 3 Each Hinges BB31 4.5 x 4.5 NRP 626 Cal -Royal I Each Classroom SL03 626 Cal -Royal I Each Wall Stop CONW342 630 Cal -Royal 3 Each Silencers DSM21 Rubber Cal -Royal Door Hardware Set No. 8 Each door to have: 3 Each Hinges BB31 4.5 x 4.5 626 Cal -Royal I Each gigital Lock CO200CY50KPRHO x IC 626 Sch Each LFIC Core Yale 626 Yale Each Wall Stop WB26 689 Cal -Royal 3 Each Silencers DSM21 Rubber Cal -Royal Door Hardware Set No. 9 Each door to have: 3 Each Hinges B B31 4.5 x 4.5 N RP 630 Cal -Royal I Each HC Panic AF770036 630 Cal -Royal I Each Trim ESC7705 626 Cal -Royal I Each Closer/Stop N900PBF x SPA900 689 Cal -Royal I Each Kick Plate BKICKI 034 630 Cal -Royal I Each Threshold "I P 628 Pemko Set 11 Seat C-8W Blk Cal -Royal Each Doors Sweep BWR-301 628 Cal -Royal I Each Rain Drip CR4462 628 Cal -Royal FBC/FPA: FI_41130.2 Door Hardware Set No. 10 Each door to have: 3 Each Hinges BB31 4.5 x 4.5 NRP 630 Cal -Royal I Each Elect. Hinge ELE4BB3I 4.5 x 4.5 630 Cal -Royal 1 Each HC Panic AF770036 &30 Cal -Royal I Each Elect. Trim FSE24HD 630 Cal -Royal I Each Closer/Stop N900PBF x SPA900 689 Cal -Royal I Each Kick Plate BKICK 1034 630 Cal -Royal I Fach Threshold 2DO I P 628 Pemko I Set Seals C-8w Blk Cal -Royal I Each Door Sweep BWR-301 628 Cal -Royal I Each Rain Drip CR4462 628 Cal -Royal I Each Power Supply CRPS202 600 Cal -Royal 1 Each Card Reader IPRW500 BLK SDC FBC/FPA: H_41130.2 Door Hardware Set No. I I Each door to have: 3 Each Hinges BB31 4.5 x 4.5 626 Cal -Royal I Each Push Plate PSPL4016 630 Cal -Royal 1 Each Pull Plate HPUL-850 619 Cal -Royal I Each Closer N900PBF 689 Cal -Royal I Each Kick Plate BKICK1 034 630 Cal -Royal I Each Wall Stop WB26 689 Cal -Royal I Each Kick Down SBDH4130O 626 Cal -Royal 3 Each Silencers DSM21 Rubber Cal -Royal Door Hardware Set No. 12 Each door to have: 3 Each Hinges BB31 4.5 x 4-5 NRP 626 Cal -Royal I Each C:assroorn SL03 626 Cal -Royal I Each C oser H der N900PBF x 901/902 689 Cal -Royal I Each mop Plafe, BKICK834 630 Cal -Royal 3 Each Silencers DSM21 Rubber Cal -Royal Door Hardware Set No. 13 Each door to have: 3 Each Hinges BB31 4.5 x 4.5 626 Cal -Royal I Each Passage SL30 626 Cal -Royal I Each Closer N90OPBF 689 Cal -Royal 1 Each Kick Plate BKICK 1034 630 Cal -Royal I Each Wall Stop WB26 689 Cal -Royal 1 Each Kick Down SBDH41300 626 Cal -Royal 3 Each Silencers DSM21 Rubber Cal -Royal Door Hardware Set No. 14 Each Door to have: 3 Each Hinges BB3l 4.5 x 4.5 626 Cal -Royal I Each Electric Strike 45-4SU 630 SDC I Each Storage SLO5 626 Cal -Royal I Each Closer N900PBF 689 Col -Royal I Each Wall Stop WB26 689 Cal -Royal 3 Each Silencers DSM21 Rubber Cal -Royal I Each Power Supply 602RF 600 SDC I Each Reader IPRW5W Blk SDC Door Hardware Set No. 15 Each door to have: 3 Each Hinges B B31 4.5 x 4.5 626 Cal-Royai I Each Passage SL30 626 Cal -Royal I Each Closer N900PBF 689 Cal -Royal I Each Wall Stop WB26 689 Cal -Royal 3 Each Silencers DSM21 Rubber Cal -Royal Door Hardware Set No. 16 Each door to have: 3 Each Hinges BB31 4.5 x 4.5 626 Cal -Royal I Each Office SLOO 626 Cal -Royal I Each Wall Stop WB26 689 Cal -Royal 3 Each Silencers DSM21 Rubber Cal -Royal Door Hardware Set No. ALI Each door to have: I Each Cont Hinge 050-821 628 Roton I Each MS 1950 628 AR I Each Cylinder AMORTCYL I 18MKD 626 Cal -Royal I Each ThumbtumTHMBMORTIOO 626 Cal -Royal 2 Each Cylinder Ring MCCRI814 626 Cal -Royal Sets 11 Pull DPA4000 1-1/4" Dia. 2,T'Length B213 630 Frasclo Each OH'Closer RTS27 BFI 628 Dorma I Each Floor Stop 535 630 Frascio I Set Seals Perimeter Blk Kawneer Door Hardware Set No. AL2 Each pair to have: I Each Cant Hinge 050-821 X EPT Prep 628 Kawneer I Each Cont Hinge 050-821 628 Kawneer I Each Electronic Power Transfer EPT 628 Kawneer I Each EL CVR E)dt 1686-MEL-Ext. Cyl 628 Kowneer I Each CVR Exit 1686 628 Kawneer 2 Each OH Offset Conc. Closers 628 Kawneer 2 Each Pulls DPA4000 1-1/4" Did. 24' Length &V Frascio I Each Cylinder AMORTCYL I 18MKD 626 CRP I Each Cylinder Ring MCCRI814 626 CRP I Set Seals Perimeter BLK Kawneer I Each Power Supply NP 1 600 Kowneer I Each Cord Reader IPRW500 BLK SDC I Each Wire Diagram xxx Kawneer TAG # TYPE GLAZING FL PRODUCT REQUIREMENTS FINISH APPROVAL # KAWNEER TRIFAB 400 SCREW SPLINE 3/8" CLEAR TEMPERED GLAZING W/ POLISHED EDGES TYP. - - PER MANUFACTURE NOTE: EXTERIOR WINDOWS SHALL MEET CURRENT KAWNEER TRIFAB 400 SCREW SPLINE 3/8" CLEAR TEMPERED GLAZING W/ POLISHED EDGES TYP. - - PER MANUFACTURE WIND ZONE REQUIREMENTS AND BE INSTALLED PER MFR KAWNEER TRIFAB 451 SCREW SPLINE 1" INSULATED GLAZING SYSTEM CLEAR. - - PER MANUFACTURE RECOMMENDATIONS. PAINTED FINISH TO MATCH ARCHITECT's APPROVED KAWNEER TRIFAB 451 SCREW SPLINE I" INSULATED GLAZING SYSTEM CLEAR. - - PER MANUFACTURE SAMPLE. KAWNEER TRIFAB 451 SCREW SPLINE I" INSULATED GLAZING SYSTEM CLEAR. - - PER MANUFACTURE KAWNEER TRIFAB 451 SCREW SPLINE I" INSULATED GLAZING SYSTEM CLEAR. - - PER MANUFACTURE Door Hardware Set No. AL3 Each door to have: I Each ContHingeOSM21 628 Raton 2 Each Pulls DPA4000 1-1 /4!'Dia. 2,('Length B26 630 Frascio I Each OH Closer 90 Deg. NHO 628 Kawneer I Each Floor Stop 535 630 Burns I Set Seals Perimeter Blk Kowneer Door Hardware Set No. AL4 Each pair to have: I Each Cont Hinge 050-821 X EPT Prep 628 Kowneer I Each Electronic Power Transfer EPT 628 Kowneer I Each EL CVR Exit 1686-MEL-Ext. Cyi 628 Kowneer I Each OH Offset Conc. Closers 628 Kowneer I Each Pulls DPA4000 1-1/4'Dia. 6CY'Length 630 Frascio E ch Cylinder AMORTCYLI 18MKD 626 CRP Each Cylinder Ring MCCR1814 626 CRP I Set Seals Perimeter BLK Kowneer I Each Power Supply NP 1 600 Kawneer I Each Card Reader IPRW500 BLK SDC I Each Wire Diagram xxx Kawneer FBC: FL 8786.1 DOOR SCHEDULE ROOM DOOR / OPENING FRAME ACCESS DOORNO NO. NAME SIZE TYPE MAT FIN MAT FIN FIRE RTNG. � HDWR. SET LOCATION CNTRL. NOTES 101A 101 LOBBY EXIST X1 EXIST EXIST EXIST EXIST N/A I EXTERIOR GC TO PROVIDE AUTO OPERATOR & PUSH BUTTONS 10113 101 LOBBY 3-0" X 7-0" E AL/GL AL/GL AL ALUM N/A ALI INTERIOR 101C 101 LOBBY 3-0" X 7-0" A WD STAIN H.M. PAINT N/A 2 INTERIOR 101D 101 LOBBY PR. 3-101" X 7'-G' D AL/GL AL/GL AL ALUM N/A AL4 INTERIOR CARD READER 102A 102 CONSULT/BROKER 3-6" X 7-0" C WD STAIN PER MFG. ALUM N/A 3 INTERIOR DOOR & FRAME FROM AD SYSTEM BARN DOOR 102B 102 CONSULT/BROKER 3-0" X 7-0" A WD STAIN H.M. PAINT N/A 4 INTERIOR 104A 104 COMMUNITY 3-0" X 7-0" A WD STAIN H.M. PAINT N/A 2 INTERIOR 104B 104 COMMUNITY PR. 2'-6" X 7-9' B WD STAIN H.M. PAINT N/A 5 INTERIOR 104C 104 COMMUNITY PR. 2'-6" X 7-9' B WD ISTAIN H.M. PAINT N/A 5 INTERIOR 104D 104 COMMUNITY 3-0" X EXIST X2 AL/GL MATCH EXIST AL MATCH EXIST N/A AL2 EXTERIOR NEW DOOR TO MATCH EXIST PROVIDE THRESHOLD & WEATHER SEAL & CLOSER 107 107 WELLNESS SUITE 1 3'-6" X 7-0" C WD STAIN PER MFG. ALUM N/A 4 INTERIOR DOOR & FRAME FROM AD SYSTEM BARN DOOR 108 108 WELLNESS SUITE 2 3-6' X 7-0" C WD STAIN PER MFG. ALUM N/A 4 INTERIOR DOOR & FRAME FROM AD SYSTEM BARN DOOR 109 109 WELLNESS SUITE 3 3-6" X 7-0" C WD STAIN PER MFG. ALUM N/A 4 INTERIOR DOOR & FRAME FROM AD SYSTEM BARN DOOR 110 110 WELLNESS SUITE 4 3-6' X 7-0" C WD STAIN PER MFG. ALUM N/A 4 INTERIOR DOOR & FRAME FROM AD SYSTEM BARN DOOR 111 BIO 3'-CY'X 7-0" A WD STAIN H.M. PAINT N/A 6 INTERIOR 112 112 WELLNESS SUITE 5 3-6' X 7-0" C WD STAIN PER MFG. ALUM N/A INTERIOR DOOR & FRAME FROM AD SYSTEM BARN DOOR 113 113 WELLNESS SUITE 6 3'-6" X 7-0" C WD STAIN PER MFG. ALUM -4 N/A 4 INTERIOR DOOR & FRAME FROM AD SYSTEM BARN DOOR 114 114 WELLNESS SUITE 7 3-6' X 7-0" C WD STAIN PER MFG. ALUM N/A 4 INTERIOR DOOR & FRAME FROM AD SYSTEM BARN DOOR 115 115 WELLNESS SUITE 8 3-6" X 7-0" C WD STAIN PER MFG. ALUM N/A 4 INTERIOR DOOR & FRAME FROM AD SYSTEM BARN DOOR 116 116 CONSULT ROOM 3'-6" X 7-0" C WD STAIN PER MFG. ALUM N/A 4 INTERIOR DOOR & FRAME FROM AD SYSTEM BARN DOOR 117 117 STORAGE 2 3-0" X 7-0" A WD STAIN H.M. PAINT N/A 7 INTERIOR 118 118 MED ROOM 3'-a'X 7-0" A WD STAIN H.M. PAINT N/A 8 INTERIOR 119 119 LAB 3'-6" X 7-0" C WD STAIN PER MFG. ALUM N/A 4 INTERIOR DOOR & FRAME FROM AD SYSTEM BARN DOOR 121 A 121 HUDDLE 3-0" X 7-0" E AL/GL AL/GL AL ALUM N/A AL3 INTERIOR PROVIDE FILM TBD 121 B 121 1HUDDLE 3'-a'X 7-10" E AL/GL JAL/GL AL ALUM N/A AL3 INTERIOR PROVIDE FILM TBD 122 122 CORRIDOR 3-0" X MATCH EXIST G H.M. PAINT H.M. PAINT N/A 9 EXTERIOR NEW EXTERIOR DOOR TO MATCH EXIST PROVIDE THRESHOLD & WEATHER STRIPPING & CLOSER 124 124 CORRIDOR 3-0" X 7-0" A WD STAIN PAINT N/A 2 INTERIOR 125 125 CORRIDOR 3'-(Y'X 7_011 A WD STAIN -H.M. H.M. PAINT N/A 11 INTERIOR 126A 126 CORRIDOR 3-0" X MATCH EXIST G H.M. PAINT H.M. PAINT N/A 10 EXTERIOR CARD READER NEW EXTERIOR DOOR TO MATCH EXIST PROVIDE THRESHOLD & WEATHER STRIPPING & CLOSER 126B 126 CORRIDOR 3-0" X 7-0" A WD STAIN H.M. PAINT N/A 12 INTERIOR 126C 126 CORRIDOR 3-0" X 7-0" A WD STAIN H.M. PAINT N/A 13 INTERIOR 126D 126 CORRIDOR 3-0" X 7-0" A WD STAIN H.M. PAINT N/A 2 INTERIOR 128 128 ICOMM ROOM 3' -0" X 7-10" A WD S TAIN H.M. PAINT N/A 14 INTERIOR CARD READER 131 131 AUTOCLAVE 3-10" X 7-0" A WD STAIN H.M. PAINT N/A 7 INTERIOR 132 132 PROVIDER WORK ROOM 3-0" X 7-0" A WD STAIN H.M. N/A 16 INTERIOR 133 133 PRACTICE ADMINISTRATOR 3-0" X 7-0" A WD STAIN H.M. -PAINT PAINT N/A 16 INTERIOR 134 134 CARE COORDINATORS 3'-G'X 7-0" A WD STAIN H.M. PAINT N/A 16 INTERIOR 135 135 ELEC. ROOM/ FIRE RISER 3'-G'X MATCH EXIST G H.M. PAINT H.M. PAINT N/A 9 EXTERIOR NEW EXTERIOR DOOR TO MATCH EXIST PROVIDE THRESHOLD & WEATHER STRIPPING & CLOSER NOTE 1: EXIT DOORS TACTILE SIGNAGE SHALL BE PROVIDED AT EACH NEW EXIT DOOR IN ACCORDANCE WITH SECTION 7.10.1.3, NFPA 101, 2015 EDITION NOTE 2: GENERAL CONTRACTOR TO PROVIDE ALL DOOR HARDWARE DOOR NOTES DOOR HARDWARE NOTES I . ALL FLUSH WOOD DOORS SHALL BE 1 3/4" THICK SOLID DOOR SPECIFICATIONS I . ALL DOOR HARDWARE TO BE LIGHT COMMERCIAL GRADE. CORE WOOD, STAIN GRADE, AND SHALL MATCH WOOD 2. CHOOSE ALL DOOR HARDWARE FROM ADA CODE -COMPLIANT PRODUCTS. SPECIES, CUT, AND STAIN OF EXISTING DOORS IN THIS SUITE. MANUFACTURER: OSHKOSH DOOR CO.; MARSHFIELD DOOR 3. ADJUST CLOSERS TO MEET HANDICAP CODE REQUIREMENTS: THE SWEEP 2. AT INTERIOR DOORS, PROVIDE 16 GA. HM FRAMES (FOR ALL SYSTEMS; OR EQUAL. PERIOD OF THE CLOSER SHALL BE ADJUSTED SO THAT FROM AN OPEN POSITION DOORS EXCEPT BIFOLD DOORS). AT ELEC. LOCKING STANDARDS: AWI SECTION 1300 PC5, WDMA IS-1 A, WI OF 70 DEGREES, THE DOOR WILL TAKE AT LEAST 3 SECONDS TO MOVE TO A DOORS- MECHANICAL LATCHES IN HEAD WITH ELECTRONIC SECTION 20 POINT 3 INCHES (75 MM) FROM THE LATCH (MEASURED TO THE LEADING EDGE STRIKES IN HEAD. CORE: SOLID CORE PARTICLE BOARD, ANSI A208.1 OF THE DOOR), PAUSE, AND THEN CLOSE. ALSO, THE FORCE REQUIRED TO 3. ALL EXTERIOR H.M. DOOR FRAMES SHALL BE GROUTED GRADE 1-LD-2 (32 LB) OPEN THE DOOR SHALL BE NO MORE THAN 5 LBS. SOLID. FACE SPECIES: NATURAL BIRCH 4. PROVIDE RATED CLOSERS ON RATED DOORS. 4. HOLD OPEN DEVICES/SELF-CLOSING DEVICE SHALL MEET FACE OUT: ROTARY 5. CLOSERS SHALL MATCH FINISH OF LATCH SET. THE FOLLOWING CRITERIA IN ACCORDANCE WITH NFPA VENEER GRADE: TYPICAL 6. KICK PLATES SHALL MATCH FINISH OF LATCH SET. 101, CHAPTER 7.2.1.8 (2015) VENEER MATCH: BOOK 7. VERIFY KEYING REQUIREMENTS WITH CLIENT. A. UPON RELEASE OF THE HOLD OPEN MECHANISM, THE VENEER ARRANGEMENT: RUNNING MATCH 8. EXCEPT AS SPECIFICALLY PERMITTED BY SECTION 1008.1.8, EGRESS DOORS LEAF BECOMES SELF -CLOSING. STILE: MATCHING VENEER SHALL BE READILY OPENABLE FROM THE EGRESS SIDE WITHOUT THE USE OF A B. THE RELEASE DEVICE IS DESIGNED SO THAT THE LEAF KEY OR SPECIAL KNOWLEDGE OR EFFORT. INSTANTLY RELEASES MANUALLY AND, UPON RELEASE, 9. SOLID GROUT HOLLOW METAL FRAMES LOCATED IN EXTERIOR WALLS. BECOMES SELF -CLOSING. 10. ALL STORAGE ROOMS TO BE LOCKED. C. THE AUTOMATIC RELEASING MECHANISM IS ACTIVATED 11. DOOR LEAVES SHALL BE ARRANGED TO BE OPENED READILY FROM THE EGRESS BY THE OPERATION OF APPROVED SMOKE DETECTORS. SIDE WHENEVER THE BUILDING IS OCCUPIED PER NFPA 101, SECTION 7.2.1.5. 1. D. UPON LOSS OF POWER TO THE HOLD OPEN DEVICE, THE MECHANISM IS RELEASED AND THE DOOR LEAF BECOMES SELF -CLOSING. E. THE RELEASE BY MEANS OF SMOKE DETECTION OF ONE DOOR LEAF IN A STAIR ENCLOSURE RESULTS IN CLOSING ALL THE DOOR LEAVES SERVING THAT STAIR, 5. ALL DOORS AND HARDWARE SHALL BE IN COMPLIANCE WITH NFPA 101 SECTION 8.3.3. ELECTROMAGNETIC SHEAR POWER SUPPLIES-\ REX­- REQUEST TO EXIST PIR OFFSET, CENTER HUNG-\ & INTERMEMATE PIVOTS \M tATCH RETRAC77ON CONTROLLER T__ L - MAGNETIC DOOR HOLDERS--\ - LOW ENERGYDOOR OPERATOR CONTROLS WALL SWITCHES DOOR ALARMS MOUNTED ELECTROMAGNETIC LOCKS PROVIDE 24V CONNECTION TO FIRE ALARM SYSTEM PANEL OR 120V IF THERE IS NO FIRE ALARM SYSTEM VIDE 120V CIRCUIT FOR ACCESS CONTROL IF NOTFED PRO AT 24V FROM ACCESS CONTROL PANEL MOUNTED ON ITB 7 CCESS C ROL 80x ACCESS CONTROL BOX KEY SWITCH ) CONCEALED CLOSERS CLOSERS PROX CARD READER & DIGITAL KEYPADS RPT,1 EP111 -CONTINUOUS HINGES Lj 0 ?OPS POWER TRANSFER S RIM, CVRSVR & MORRSE EXIT DEVICES ELECTRIFIED HINGES ELECTRIFIED P/VOT' _____REMOVABLE & CYLINDRICAL LOCKS & MORTISE LOCKS NON -REMOVABLE MULLIONS ELECTRIFIED TRIM -------- ij BUTTHINGES I --J--FLOOR CLOSERS WEATHER STRIPPING, SWEEPS, THRESHOLDS, FLUSH -BOLTS, DOOR ELECTRIC S STOPS, DOOR HOLDERS AND KICK PLATES DF-3)TYPICAL ACCESS CONTROL DETAIL A2.3 NOT TO SCALE ACCESS CONTROL DETAIL NOTES: ACCESS CONTROLLED EGRESS DOORS SHALL BE IN ACCORDANCE WITH NFPA 101, CHAPTER 7.2.1.6.2. (2012 EDITION). ACCESS CONTROLLED EGRESS DOORS COMPLYING WITH 7.2.1.6.2 SHALL BE PERMITTED (SECTION 38.2.2.2.6, NFPA 101, 2009 EDITION). ACCESS C01ffROL DEVICES SHALL BE UL 294 LISTED AND INSTALLATION SHALL INCLUDE.7 1. SENSOR SHALL BE PROVIDED ON EGRESS SIDE OF DOOR TO DETECT AN OCCUPANT APPROACHING THE DOOR& 2. DOORS SHALL UNLOCKAUTONATICALLY UPON LOSS OF POWER TO THE SENSOR. 3. PROVIDEPUSH TO EXJr MANUAL UNLOCKING DEVICE LOCATED 4ff'TO 4ir'VERTICALLYABOVE THE FLOORAND WITHIN 5'-IP'OF THE SECURE DOORS WITH WIRING AS REQUIRED. 7. THE EGRESS SIDE OF THE DOORS SHALL BE PROVIDED WITH EMERGENCY LIGHTING. & ACTIVATION OF THE BUILDING FIRE PROTECTIVE SIGNALING SYSTEM SHALL AUTOMATICALLY UNLOCK THE DOORS, AND DOORS SHALL REMAIN UNLOCKED UNTIL THE FIRE ALARM SYSTEM HAS BEEN RESET. 9. ACTIVATION OF MANUAL FIRE ALARM REQUIREMENTS SHALL AUTOMATICALLY UNLOCK THE DOORS, AND DOORS SHALL REMAIN UNLOCKED UNTIL THE FIRE ALARM SYSTEM HAS BEEN RESET 10. ACTIVATION OF THE BUILDING AUTOMATIC SPRINKLERS OR FIRE DETECTION SYSTEM SHALL AUTOMATICALLY UNLOCK THE DOORS, AND DOORS SHALL RENAINUNLOCKED UNTIL THEFIREALARM SYSTENHAS BEENRESET. 11. COORDINATE SPECIFICATION AND REQUIREMENTS FORACCESS CONTROL WITNARCHITECTS CONSTRUCTION DOCUMENTS AND OWNERITEN4NT CONTRACTED ACCESS CONTROL CONTRACTOR. NOTE. DETAIL SHOWS MULTIPLE POSSIBLE ACCESS CONTROL CONFIGURATIONS AND POSSIBLE ROUGH -IN. VERIFYACTUAL JOB SPECIFIC REQUIREMENTS FOR THIS PROJECT PRIOR TO ROUGH -IN. CAMPBELL +VAN DUSEN ARCHITECTURE INTERIOR DESIGN www.CVDstudio.com CAMPBELL + VAN DUSEN Design Studio, LLC. 255 South Orange Avenue Suite # 1240 Orlando, Florida 32801 Phone: 407.930.6016 FL. Lic. No. AROO 16053 -A ARCHITECT OF RECORD FRANK W. CAMPBELL AIA FL LIC NO. AR001 6053 COPY OF THIS PLAN Is NOT VALID UNLESS SIGNED, SEALED AND DATED BY THE ARCHITECT OF RECORD COPY OF THIS PLAN IS NOT VALID UNLESS SIGNED, SEALED AND DATED BY THE ENGINEER OF RECORD LL (j 0 CL t-4 < 0 > LU LjLj 0 + L 0 _j _j 0 "o < LU --- ) > 0 0 U_j -0 Lr) < Lu CO (y) r.-I M CONSTRUCTION DOCUMENTS 03.24.2023 PRINCIPAL IN CHARGE F. CAMPBELL . ... .. .. ...... P I R . OJECT . MA . NAGER .................................................. M. TORRES .................................................................... ADVENT HEALTH WELL 65+ ZEPHYRHILLS 22-0328-01 DOOR & WINDOW ELEVATIONS & SCHEDULE A2.3 LAY -IN PANEL -\ '�'AOOM. 2- CROSS TEE NOM. 4'CROSS TEE MAIN BEAM NOTE: MINSTALL PER ASTIVI 636 i MAXIMUM DEFLECTION OF HANGER WIRE IS 16:6. PROVIDE ADDITIONAL SUPPORTS AS REQUIRED. (CL-j� SUSPENDED CEILING DETAIL I � A3.0 ) I I 41 HANGER WIRE 12 GA MIN. 4'O.C. SECURE TO STRUCTURE W/ POWDER ACTUATED FASTENERS. HILTI X-CX ALH OR EQUAL � M, - I X" -11 TEGULAR EDGE WELLNESS SUITE REFLECTED CEILING PLAN 1/411 = 1 1-0" STRUCTURE ABOVE SECURE TRACK TO STRUCTURE: USE POWER DRIVEN FASTENERS AT 24" O.C. (MAX.) 3 5/8" GALV. METAL STUD F AM A STRUCTURE ABOVE ,mk 10'-O"A.F.F o o o ACOUSTICAL CEILIN 9'-0" A.F.F A111-1 5/8" DRYWALL (TYP.) x 5/8" DRYWALL (TYP.) `*—�-1AFF ,L-5 CEILING DETAIL il n SCALE: I" = 1'-0" 12 GA. HANGER WIRE WRAP WIRE MIN. 3 TIMES IN 3 INCHES 'T'BAR MAIN BEAM SCALE: N.T.S. EXISTING STRUCTURE POWER DRIVEN FASTENERS 12 GA. WIRE HANGERS MAX 6" FROM WALL 12 GA. WIRE HANGERS MAX 4'C.0 I 0'-a- A.F.Fgk �w ACOUSTICAL CEILING PERIMETER TRIMS WALL CEILING DETAIL SCALE: I" = I'-G' STRUCTURE ABOVE SECURE TRACK TO STRUCTURE.J USE POWER DRIVEN FASTENERS AT 24" O.C. (MAX.) 3 5/8" GALV. METAL STUD FRAMING AT 16'O.C. TO JBRACE TO STRUCTURE STRUCTURE ABOVE i 10'-0" A.F F 10'-O"A.F.F 'OUSTICAL CEILING REFER TO CEILING PLAN FOR HEIGHT 8'-Z'A.F.F. 5/8" GWB W/ HEADER UX 10--- CORNER BEAD* (C'L--3"� CEILING DETAIL � Al n ) SCALE: I" = Y-0" STRUCTURE ABOVE 3 5/8" GALV. METAL STUD FRAMING AT 16" O.C. TO STRUCTURE ABOVE PARTITION SEE PLAN o o o 10'-O"A.F.F U L ACOUSTICAL CEILING A Co S TIC A RE F T E 11 REFER TO CEILING PLAN ER 0 C IL R HE 1 G T FOR HEIGHT Fo H )7PLAN; CROWN MOLDING WHERE NOTED IN CROW N MOLC SEE DET. A/A3.0 YW LL 5/8" DRYWALL (TYP.) 9'-0" A.F.F 1" DRYWALL TYP. (TYP. Co RNER BEAD (TYP.) '�..`EILING DETAIL SCALE: I" = Y-0" 7 4 6 5 —T—i CEILING HEIGHT VARIES SEE REFLECTED CEILING ACOUSTICAL CLG. TILE CROWN MOLDING FYPON MLD453-16 TYP. CROWN MOLDING DETAIL SCALE: NTS CEILING & LIGHTING LEGEND NEW CEILING GRID WITH 2'x 2'x 5/8" ACOUSTICAL CEILING TILE - MANUFACTURED BY USG - OLYMPIC MICRO TEGULAR, COLOR: WHITE 2'X 2'LAY-IN LED LIGHT IN ACOUSTICAL TILE CEILING GYPSUM BOARD CEILING RECESSED DOWN LIGHT 0 (SEE ELECT. DWGS.) PENDANT MOUNTED FIXTURE (SEE ELECT. DWGS.) DECORATIVE PENDANT (SEE ELECT. DWGS.) 24X24 LOCKABLE ACCESS PANEL. PAINT TO MATCH CEILING SUPPLY DIFFUSER Fz-1 RETURN DIFFUSER EXHAUST FAN NEW SOFFIT / HEADER CEILING/SOFFIT HEIGHT 9'-0" A. F. F FIRE SPRINKLER. REFER TO PLUMBING SHEET FOR LOCATIONS. EXIT LIGHT, SINGLE FACE. LETTER INDICATES FIXTURE TYPE. BLACK QUADRANT INDICATES DIRECTION OF FACE, ARROW(S) INDICATE DIRECTION OF TRAVEL. SEE ELECTRICAL SHEETS. RECESSED DOWN LIGHT WALL WASHER (SEE ELECT. 13 DWGS.) WALL SCONCE. (SEE ELECT. DWGS.) CROWN MOLDING NOTE: VERIFY AND COORDINATE LIGHTS AND HVAC EQUIPMENT PLACEMENT WITH MECHANICAL AND ELECTRICAL DRAWINGS. REFLECTED CEILING PLAN CI LIGHTING PLACEMENT IS EXTREMELY IMPORTANT IN SOME ROOMS. IF CONTRACTOR BELIEVES THE CEILING GRID WILL NOT LAYOUT EXACTLY AS DRAWN, ARCHITECT IS TO BE NOTIFIED BEFORE BEGINNING WORK. C2 SOFFITS: GYP BOARD ON FRAMING @ 16" O.C. SUSP ENDED FROM STRUCTURE ABOVE OR WALL. VERIFY ALL SOFFIT DIMENSIONS WITH CABINET DWGS, INTERIOR ELEVATIONS OR SECTION DETAILS. C3 PROVIDE & INSTALL SOUND BATT INSULATION ABOVE ACOUSTICAL CEILINGS AT H.C. TOILETS, STAFF RM. & I.T. RM. C4 VERIFY CLIENT'S REQUIREMENTS FOR MUSIC, INTERCOM, VCR/TV LOCATIONS, AND CONNECTIONS TO BASE LOCATIONS. C5 SEE MECHANICAL AND ELECTRICAL PLANS FOR EQUIPMENT AND FIXTURES IN CEILING. IF CONTRACTOR BELIEVES THAT CEILING GRID WILL NOT LAY OUT EXACTLY AS DRAWN, HE SHALL CONTACT ARCHITECT BEFORE BEGINNING WORK. C6 ALL NEW ACOUSTICAL CEILING HT = 10'-0" AFF. U.N.O. C7 TOP OF EXISTING EXTERIOR WINDOWS & WALL 12'-0" ABBREVIATIONS: AFF ABOVE FINISH FLOOR CLG CEILING EQ EQUAL HDR HEADER POR POINT OF REFERENCE PT PREASSURE TREATED TYP TYPICAL N NEW ETR EXISTING TO REMAIN CEILING LAYOUT NOTES: NOTE: Xs IN ROOMS ARE FOR REFERENCE AND COORDINATION OF CEILING PLACEMENT WITH DRAWING. USE DIMENSIONS, WHERE PRESENT, IN ADDITION TO X. NOTE: VERIFY AND COORDINATE LIGHT SELECTIONS AND HVAC EQUIPMENT PLACEMENT WITH MECHANICAL AND ELECTRICAL. k,Amrt5r-LL -t- VAIN L)U3r-1N ARCHITECTURE INTERIOR DESIGN www.CVDstudio.com CAMPBELL + VAN DUSEN Design Studio, LLC. 255 South Orange Avenue Suite # 1240 Orlando, Florida 32801 Phone: 407.930.6016 FL. Lic. No. AR001 6053 ARCHITECT OF RECORD FRANK W. CAMPBELL AIA I'LLIC NO. AR0016053 COPY OF THIS PLAN IS NOT VALID UNLESS SIGNED, SEALED AND DATED BY THE ARCHITECT OF RECORD COPY OF THIS PLAN IS NOT VALID UNLESS SIGNED, SEALED AND DATED BY THE ENGINEER OF RECORD -j LL- 0 F— CL CL LU u < (/) > LU LU -j 0 F— + LO oe < LU LU '0 0 > '0 Lo LU w CL LU r-4 00 (y) r-, M CONSTRUCTION DOCUMENTS m 03.24.2023 DESCRIPTION PRINCIPAL IN CHARGE F. CAMPBELL .. ....................................... I ......................... PROJECT MANAGER M. TORRES ............................................................... ADVENT HEALTH WELL 65+ ZEPHYRHILLS 22-0328-01 REFLECTED CEILING PLAN A3.0 STRUCTURE ABOVE 3 5/8" GALV. METAL STUD FRAMING AT 16" O.C. TO STRUCTURE ABOVE EXTERIOR WALL OR PARTITION SEE PLAN 5/8" DRYWALL (TYP.) 1101FAM 19 J ACOUSTICAL CEILING REFER TO CEILING PLAN FOR HEIGHT CROWN MOLDING WHERE NOTED IN PLAN; SEE DET. A/A3.0 RECESSED CAN LIGHT - SEE ELEC DWGS CORNER BEAD (TYP.) WALL WIDTH VARIES SEE PLAN s, CEILING DETAIL SCALE: V V-0" STRUCTURE ABOVE 3 5/8" GALV. METAL STUD FRAMING AT 16" O.C. TO STRUCTURE ABOVE PARTITION SEE PLA 19-0" A.F.F ACOUSTICAL CEILING REFER TO CEILING PLAN FOR HEIGHT CROWN MOLDING; SEE DET. A/A3.0 5/8" DRYWALL (TYP.) CORNER BEAD (TYP.) 7'-Z'A.F.F 5/8" DRYWALL (TYP.) CEILING DETAIL SCALE: 1 V-0" STRUCTURE ABOVE 3 5/8" GALV. METAL STUD FRAMING AT 16'O.C. TO STRUCTURE ABOVE PARTITION SEE PLAN Ilk ACOUSTICAL CEILING REFER TO CEILING PLAN FOR HEIGHT 7-0" A.F.F CROWN MOLDING; SEE DET. A/A3.0 5/8" DRYWALL (TYP.) CORNER BEAD (TYP.) 7'4" A.F.F 5/8" DRYWALL (TYP.) 1-4" L �-86 CEILING DETAIL A1� 3.1 SCALE: V V-0" STRUCTURE ABOVE 3 5/8" GALV. METAL STUD FRAMING AT 16" O.C. TO STRUCTURE ABOVE PARTITION SEE PLAN 111z1ffw1m�j1hq J ACOUSTICAL CEILING REFER TO CEILING PLAN FOR HEIGHT _`5/8" DRYWALL (TYP.) 7'-2" A.F.F 5/8" DRYWALL (TYP. CORNER BEAD (TYP.) WALL DETAIL SCALE: 1" 1'-0" STRUCTURE ABOVE 3 5/8" GALV. METAL STUD FRAMING AT 16" O.C. TO STRUCTURE ABOVE PARTITION SEE PLAN 9'-g'A.F.F ACOUSTICAL CEILING REFER TO CEILING PLAN FOR HEIGHT 5/8" DRYWALL (TYP.) 7'-2" A.F.F ---CORNER BEAD (TYP.) DRYWALL (TYP. WALL �'NEILING DETAIL SCALE: I" V-0" STRUCTURE ABOVE 3 5/8" GALV. METAL STUD FRAMING AT 16" O.C. TO STRUCTURE ABOVE PARTITION SEE PLAN 10'-9'A.F.F ACOUSTICAL CEILING REFER TO CEILING PLAN FOR HEIGHT 5/8" DRYWALL (TYP.) 7-8" A.F.F DRYWALL (TYP.J�, 'CORNER BEAD (TYP.) WALL ..EILING DETAIL SCALE: I" V-0" STRUCTURE ABOVE 3 5/8" GALV. METAL STUD FRAMING AT 16" O.C. TO STRUCTURE ABOVE PARTITION SEE PLAN 111AIMAXW119, -A ACOUSTICAL CEILING REFER TO CEILING PLAN FOR HEIGHT 5/8" DRYWALL (TYP.) 7'-4" A.F.F DRYWALL (TYP- ---CORNER BEAD (TYP.) j� WALL NEILING DETAIL SCALE: I" V-0" STRUCTURE ABOVE 3 5/8" GALV. METAL STUD FRAMING AT 16'O.C. TO STRUCTURE ABOVE PARTITION SEE PLAN I O'Z' A.F.F ACOUSTICAL CEILING REFER TO CEILING PLAN FOR HEIGHT 5/8" DRYWALL (TYP.) 9'-0" A.F.F DRYWALL (TYP.y�, 'CORNER BEAD (TYP.) WALL '*.EILING DETAIL SCALE: I" = V-0" CAMPBELL +VAN DUSEN ARCHITECTURE INTERIOR DESIGN www.CVDsfudio.com CAMPBELL + VAN DUSEN Design Studio, LLC. 255 South Orange Avenue Suite # 1240 Orlando, Florida 32801 Phone: 407.930.6016 FL. Lic. No. AR001 6053 ARCHITECT OF RECORD FRANK W. CAMPBELL AIA FL LIC NO. AR001 6053 COPY OF THIS PLAN IS NOT VALID UNLESS SIGNED, SEALED AND DATED BY THE ARCHITECT OF RECORD COPY OF THIS PLAN IS NOT VALID UNLESS SIGNED, SEALED AND DATED BY THE ENGINEER OF RECORD LL_ 0 CL a- -T- LU ry < Q > U_j Uj _j n = + LO ,,0 fl:� < Uj I LU I = > 0 C) LU r) 110 ,0 LO Iry LU r-4 00 (y) tN-, CO CONSTRUCTION DOCUMENTS 03.24.2023 PRINCIPAL IN CHARGE F. CAMPBELL .................................................................... PROJECT MANAGER MJO.RRES ....................................................... ADVENT HEALTH WELL 65+ ZEPHYRHILLS 22-0328-01 SOFFIT DETAILS A3.1 CAMPBELL + VAN DUSEN ARCHITECTURE INTERIOR DESIGN www.CVDstudio.com CAMPBELL + VAN DUSEN Design Studio, LLC. 255 South Orange Avenue Suite # 1240 Orlando, Florida 32801 Phone: 407.930.6016 FL. Lic. No. AR0016053 ARCHITECT OF RECORD FRANK W. CAMPBELL AIA FL LIC NO. AR0016053 COPY OF THIS PLAN IS NOT VALID UNLESS SIGNED, SEALED AND DATED BY THE ARCHITECT OF RECORD COPY OF THIS PLAN IS NOT VALID UNLESS SIGNED, SEALED AND DATED BY THE ENGINEER OF RECORD J LL Z O = CL CL L1J U N w � C) Uz`r'�Q �,o W oww '0� OL Q >V I � M CONSTRUCTION DOCUMENTS 03.24.2023 NO. DATE DESCRIPTION PRINCIPAL IN CHARGE F. CAMPBELL .................................................................... PROJECT MANAGER M. TORRES ................................................................. ADVENT HEALTH WELL 65+ ZEPHYRHILLS 22-0328-01 FINISH PLAN 1 /A4.0 A4e0 FcE ILING WALL I BASE PLAN LEGEND: LLOR j CEILING FLOORING, WALL BASE AND TRANSITION STRIPS PAINT, WALLCOVERING AND WALL TILE SURFACES CEILING TYPE I FVCT21 VINYL COMPOSITION TILE 2 FWvq1 WALLCOVERING - 9 -1 QUARTZ SOLID SURFACE COUNTERTOP - 2 F572 ACOUSTICAL CEILING TILE AND GRID SYSTEM MANUFACTURER: ARMSTRONG FLOORING DISTRIBUTOR: NATIONAL SOLUTIONS MANUFACTURER: DALTILE MANUFACTURER: USG STYLE: STANDARD EXCELON IMPERIAL TEXTURE PATTERN: PAVE COLOR: SIMPLY WHITE NQ76 STYLE: OLYMPIC MICRO TEGULAR COLOR: BLUE/GRAY 51903 COLOR: BEVELED GLASS Y46285PV FINISH: POLISHED COLOR: WHITE TILES AND WHITE GRID SIZE: 12"X12" WIDTH: 54" THICKNESS: 3 CM SIZE: 2'X 2'X 5/9' INSTALL PATTERN: STRAIGHT LOCATION: AS INDICATED ON PLAN EDGE PROFILE: EASED EDGE r CL2 CEILING TYPE 2 LOCATION: AS INDICATED ON PLAN. NOTES: MICROPERFORATE WHEN INSTALLED ON EXTERIOR WALL. LOCATION: PROVIDER & HUDDLE COUNTERTOPS DRYWALL CEILINGS AND SOFFITS NOTES: INSTALL PER MANUFACTURER'S REQUIREMENTS. INSTALL A CONTACT ANN RANK AT (407)491-1752 OR ARANK@MDCWALL.COM NOTES: 2" CORNER FOR COUNTER TOPS FINISH: TRANSITION STRIP AT ALL FLOORING TRANSITIONS. CONTACT WILLIAM 1. WISE AT (803)728-7077 OR WIWISE@ARMSTRONGFLOORING.COM. F71-01 WALLCOVERING - 10 FSS3 SOLID SURFACE COUNTERTOP - 3 FLOORING, WALL BASE AND TRANSITION STRIPS VINYL WALL BASE - I DISTRIBUTOR: NATIONAL SOLUTIONS MANUFACTURER: CORIAN MANUFACTURER: ROPPE PATTERN: PAVE COLOR: SPARKLING WHITE r -L V-T- -1 LUXURY VINYL COMPOSITION TILE - I STYLE: SIMPLICITY BOLD PV4005 COLOR: CLAY MASK Y47322PV FINISH: POLISHED MANUFACTURER: SHAW CONTRACT COLOR: 194 BURNT UMBER WIDTH: 54" THICKNESS: 1/2" STYLE: COVER 4140V SIZE: 4-1/2" HIGH LOCATION: AS INDICATED ON PLAN EDGE PROFILE: EASED EDGE COLOR: PRESERVE 07067 LOCATION: THROUGHOUT AS INDICATED; ON MILLWORK BASE CABINETS NOTES: MICROPERFORATE WHEN INSTALLED ON EXTERIOR WALL. LOCATION: WELLNESS SUIT ROOMS COUNTEROPS SIZE: 7'X 59" AT FINISHED FLOOR CONTACT ANN RANK AT (407)491-1752 OR ARANK@MDCWALL.COM NOTES: 2" CORNER FOR COUNTER TOPS INSTALL PATTERN: STAGGER NOTES: PROVIDE PRE -FORMED CORNERS. PROVIDE IN 120'CONTINUOUS LOCATION: AS INDICATED ON PLAN. COILS. F-D WALL TILE I SOLID SURFACE COUNTERTOP 4 NOTES: INSTALL PER MANUFACTURER'S REQUIREMENTS. USE A SHAW TRANSITION STRIP - I DISTRIBUTOR: CERAMIC TECHNICS LTD - MANUFACTURED/APPROVED ADHESIVE. INSTALL A TRANSITION STRIP AT ALL MANUFACTURER: TBD STYLE: STUDIO MARMI METRO MANUFACTURER: CORIAN FLOORING TRANSITIONS. CONTACT VIRNA MITCHELL AT STYLE: COLOR: FLAVUS COLOR: WEATHERED CONCRETE VIRNA.MITCHELL@SHAWCONTRACT.COM OR (407)405-0422 SIZE: TO BE DETERMINED BY INSTALLER SIZE: 4"X 12" FINISH: POLISHED FNT2� LUXURY VINYL COMPOSITION TILE - 2 COLOR: LOCATION: AS NOTED ON PLAN - LVTI TO CPT GROUT: TBD GROUT JOINT WIDTH: TBD THICKNESS: 1/2" EDGE PROFILE: EASED EDGE MANUFACTURER: SHAW CONTRACT NOTES: CONFIRM PROFILE IS APPROPRIATE FOR APPLICATION & PER ADAAG. INSTALL PATTERN: TBD LOCATION: WORKSPACE COUNTEROPS STYLE: COVER 4140V LOCATION: AS INDICATED ON PLAN NOTES: 2" CORNER FOR COUNTER TOPS COLOR: SECURE 07068 SIZE: 7'X 59" PAINT, WALLCOVERING AND WALL TILE NOTES: TO ORDER CONTACT HOWIE HERSKOVITS AT (888)541-3840 EXT 165 INSTALL PATTERN: STAGGER OR HOWIE@TILEBAR.COM ALL WINDOW TREATMENT WILL BE MECHO 1-3 % OPACITY LOCATION: AS INDICATED ON PLAN. PAINT - I MANUAL ROLLER SHADE FINISH PATTERN KEY: NOTES: INSTALL PER MANUFACTURER'S REQUIREMENTS. USE A SHAW MANUFACTURED/APPROVED ADHESIVE. INSTALL A TRANSITION STRIP AT ALL MANUFACTURER: SHERWIN WILLIAMS COLOR: NATURAL CHOICE SW7011 F7T2 WALL TILE 2 FINISH PATTERN KEY: WT3 WALL TILE 3 - TOILET 104-138 FLOORING TRANSITIONS. CONTACT VIRNA MITCHELL AT SHEEN: EGGSHELL DISTRIBUTOR: SOHO STUDIO STYLE: ALCHIMIA TLCFALCMBLU3XI2 VIRNA.MITCHELL@SHAWCONTRACT.COM OR (407)405-0422 LOCATION: THROUGHOUT U.N.O. COLOR: ALCHIMIA BLUE LAY DIRECTION INDICATOR PAINT - I A SIZE: 3"X 12" GROUT: TBD LVT1 /2 LUXURY VINYL TILE I & 2 - STAGGER CARPET TILE - 1 MANUFACTURER: SHERWIN WILLIAMS MANUFACTURER: SHAW COLOR: NATURAL CHOICE SW7011 GROUT JOINT WIDTH: TBD 000 COLLECTION: COLLECTIVE SHEEN: SEMI -GLOSS INSTALL PATTERN: TBD I 000 DESIGN: SIDE BY SIDE 5T452 LOCATION: DOOR FRAMES THROUGHOUT LOCATION: FLOOR TO CEILING AS INDICATED ON PLAN 000 COLOR: TOGETHER 50210 NOTES: TO ORDER CONTACT HOWIE HERSKOVITS AT (888)541-3840 EXT 165 SIZE: I 9'X 36' OR HOWIE@TILEBAR.COM E_ INSTALL PATTERN: ASHLAR F _PT2 PAINT - 2 LOCATION: AS INDICATED ON PLAN. MANUFACTURER: SHERWIN WILLIAMS EW3] WALL TILE 3 1 NOTES: INSTALL PER MANUFACTURER'S REQUIREMENTS. USE SHAW COLOR: EXTRA WHITE SW7006 DISTRIBUTOR: WOW MANUFACTURED/APPROVED ADHESIVE. INSTALL A TRANSITION STRIP AT ALL SHEEN: EGGSHELL STYLE: TRAPEZIUM T_ FLOORING TRANSITIONS. LOCATION: TRIM COLOR: ICE WHITE MATT SIZE: 4"X9" T_ WT3&4 WALL TILE 3&4 - TOILET 103 ETPT3 PAINT - 3 GROUT: TBD EEfl CARPET TILE - 2 MANUFACTURER: SHERWIN WILLIAMS GROUT JOINT WIDTH: TBD LVT I LUXURY VINYL TILE 1 -HERRINGBONE MANUFACTURER: MILLIKEN COLOR: BIG CHILL SW 7648 INSTALL PATTERN: TBD -0- COLLECTION: EDGE KIT SHEEN: EGGSHELL LOCATION: FLOOR TO CEILING AS INDICATED ON PLAN 000 0 DESIGN: EDGE LIT LOCATION: AS INDICATED ON PLAN. NOTES: TO ORDER CONTACT HOWIE HERSKOVITS AT (888)541-3840 EXT 165 COLOR: MERCURY EDG 107-133 OR HOWIE@TILEBAR.COM SIZE: 9.85" X 39.4" ED PAINT - 4 INSTALL PATTERN: ASHLAR MANUFACTURER: SHERWIN WILLIAMS ETTF41 WALL TILE 4 LOCATION: AS INDICATED ON PLAN. COLOR: TARNISHED TRUMPET SW 9026 DISTRIBUTOR: WOW NOTES: 307. OF OVERALL PATTERN WHEN INSTALLED WITH CPT3. INSTALL PER SHEEN: EGGSHELL STYLE: HEXA MANUFACTURER'S REQUIREMENTS. USE A MILLIKEN LOCATION: ACCENT WHERE INDICATED COLOR: ASHY GREY MATT MANUFACTURED/APPROVED ADHESIVE. INSTALL A TRANSITION STRIP AT ALL SIZE: 9'X9" FLOORING TRANSITIONS. CONTACT ROSIE STERLING AT GROUT: TBD ROSIE.STERLING@MILLIKEN.COM OR (407)580-7909 Fw—v D WALLCOVERING - I GROUT JOINT WIDTH: TBD Fc -PT31 CARPET TILE - 3 DISTRIBUTOR: MDC INTERIOR SOLUTIONS INSTALL PATTERN: TBD LOCATION: AS INDICATED ON PLAN WT3 WALL TILE 3 - TOILET 107 MANUFACTURER: MILLIKEN COLLECTION: CANDICE OLSON COUTURE COLLECTION: EDGE LIT PATTERN: GLIMMER NOTES: TO ORDER CONTACT HOWIE HERSKOVITS AT (888)541-3840 EXT 165 CPT2-5 - CARPET TILE 2-5 - ASHLAR DESIGN: EDGE LIT COLOR: EBONY MCO 1708/4145 OR HOWIE@TILEBAR.COM COLOR: EDG259-120 ARGON WIDTH: 54�' CORNER GUARD I SIZE: 9.85" X 39.4" LOCATION: AS INDICATED ON PLAN MANUFACTURER: ACROVYN INSTALL PATTERN: ASHLAR NOTES: MICROPERFORATE WHEN INSTALLED ON EXTERIOR WALL. COLLECTION: SUEDE LOCATION: AS INDICATED ON PLAN. CONTACT ANN RANK AT (407)491-1752 OR ARANK@MDCWALL.COM WING AT 90 DEGREE CORNERS (VA-024N) NOTES: 70% OF OVERALL PATTERN WHEN INSTALLED WITH CPT2. INSTALL PER 1 -1 /Z'WING @ ANGLES OTHER THAN 90 DEGREES (VA-20OMN) MANUFACTURER'S REQUIREMENTS. USE A MILLIKEN Ew­V2� WALLCOVERING - 2 COLOR: EGGSHELL #100 MANUFACTURED/APPROVED ADHESIVE. INSTALL A TRANSITION STRIP AT ALL DISTRIBUTOR: MAGNOLIA HOME SIZE: 8'-U'LENGTHS FLOORING TRANSITIONS. CONTACT ROSIE STERLING AT PATTERN: FOUNDATIONS GEOMETRIC TRIAGLES SHADOW LOCATION: AS INDICATED ON PLAN ROSIE.STERLING@MILLIKEN.COM OR (407)580-7909 COLOR: MAGI 153 NOTES: PROVIDE NO TAPE VERSION AND INSTALL WITH ADHESIVE IN WIDTH: 54" THE FIELD CARPET TILE -4 LOCATION: AS INDICATED ON PLAN MANUFACTURER: MILLIKEN NOTES: MICROPERFORATE WHEN INSTALLED ON EXTERIOR WALL. EFRP GLASS FIBER REINFORCED PLASTIC PANELING FRP TO 48" AF L COLLECTION: COMFORTABLE CONCRETE CONTACT ANN RANK AT (407)491-1752 OR ARANK@MDCWALL.COM MANUFACTURER: CRANE COMPOSITES LOCATION: AS INDICATP ON rLAN DESIGN: URBAN SKETCH PRODUCT NAME: GLASBORD WALL PANELS WITH SURFASEAL FINISH NOTES: PROVIDE NO TAPE VERSION AND INSTALL WITH ADHESIVE IN COLOR: URS 180-153 OYSTER SHELL WALLCOVERING 3 COLOR: WHITE 85 ftj F RbOR TILE 1 1/3 OFFSET GENERAL PLAN NOTES: 0 SIZE: 19.7'X 19.7' Fw_V 3] - TEXTURE: SMOOTH TEXTURE FINISH INSTALL PATTERN: TBD DISTRIBUTOR: NATIONAL SOLUTIONS SIZE: 4'X 8' (0.0075" THICK) LOCATION: AS INDICATED ON PLAN. PATTERN: PAVE LOCATION: AS INDICATED ON PLAN NOTES: INSTALL PER MANUFACTURIER'S REQUIREMENTS. USE A MILLIKEN COLOR: METALLO Y46289PV NOTES: INSTALL WITH MATCHED PVC MOULDINGS.VERTICAL I . NOTIFY THE ARCHITECT REGARDING ANY DISCREPANCIES PRIOR TO PROCEEDING MANUFACTURED/APPROVED ADHESIVE. INSTALL A TRANSITION STRIP AT ALL WIDTH: 54" ORIENTATION- INSTALL TO 4'AFF WITH THE WORK. FLOORING TRANSITIONS. CONTACT ROSIE STERLING AT LOCATION: AS INDICATED ON PLAN ROSIE.STERLING@MILLIKEN.COM OR (407)580-7909 NOTES: MICROPERFORATE WHEN INSTALLED ON EXTERIOR WALL. 2. ALL INTERIOR WALL AND CEILING FINISHES SHALL BE NOT LESS THAN CLASS C CONTACT ANN RANK AT (407)491-1752 OR ARANK@MDCWALL.COM EWE1] WALL EDGE - 1 (0.22 WATTS/CM SQ.) FOR MINIMUM CRITICAL FLUX IN ACCORDANCE WITH FC CARPET TILE - 5 MANUFACTURER: SCHLUTER SYSTEMS NFPA 101 AND MEET FLAME SPREAD REQUIREMENTS AND SMOKE DEVELOPMENT IN P T75 MANUFACTURER: MILLIKEN FWV74 WALLCOVERING - 4 STYLE:TBS COLOR: ACCORDANCE WITH ASTM E-84 PER TABLE LISTED BELOW. PROVIDE PRODUCT COMFORTABLE CONCRETE DISTRIBUTOR: NATIONAL SOLUTIONS CERTIFICATIONS TO AUTHORITY HAVING JURISDICTION FOR PROOF OF ElCOLLECTION: DESIGN: URBAN VISTA PATTERN: PAVE SIZE: TO BE DETERMINED BY INSTALLER COMPLIANCE. COLOR: URV05-219-180 PARCHED SAND COLOR: BIRCH Y46288PV LOCATION: EXPOSED EDGE OF WALL TILE 5 SIZE: 19.7'X 19.7' WIDTH: 54" NOTES: TO ORDER CONTACT MATT LONG AT (407)795-0794 OR 3. CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR THE ACCURACY OF THE INSTALL PATTERN: ASHLAR LOCATION: AS INDICATED ON PLAN MLONG@SCHLUTER.COM VCT1 VINYL COMPOSITION TILE I STACKED CONTRACTOR'S MEASUREMENTS AND TOTAL YARDAGE REQUIREMENTS TO BE LOCATION: AS INDICATED ON PLAN. NOTES: MICROPERFORATE WHEN INSTALLED ON EXTERIOR WALL. FURNISHED. NO REQUESTS FOR MATERIALS OR INSTALLATION EXTRAS WILL BE NOTES: 107. OF OVERALL PATTERN WHEN USED WITH CPT6. INSTALL PER CONTACT ANN RANK AT (407)491-1752 OR ARANK@MDCWALL.COM GLASS FILM FOR HUDDLE ROOM ALLOWANCE $10,000 CONSIDERED DUE TO MEASUREMENT OR TAKEOFF ERRORS BY CONTRACTOR. kAA MHr-A(-THPFP"Z PPQHIPrhAENT�Z HSE A KAI' I IVEN MANUFACTURED/APPROVED ADHESIVE. INSTALL A TRANSITION STRIP AT ALL WALLCOVERING - 5 SURFACES FLOORING TRANSITIONS. CONTACT ROSIE STERLING AT FWV5] DISTRIBUTOR: NATIONAL SOLUTIONS ROSIE.STERLING@MILLIKEN.COM OR (407)580-7909 PATTERN: PAVE PLASTIC LAMINATE - I COLOR: MARSH ROOT Y46292PV MANUFACTURER: WILSONART Fc-p-T6] CARPET TILE - 6 WIDTH: 54" COLOR: VERANDA TEAK 8209K-28 MANUFACTURER: MILLIKEN LOCATION: AS INDICATED ON PLAN FINISH: GLOSS LINE FINISH WITH AEON ElCOLLECTION: COMFORTABLE CONCRETE NOTES: MICROPERFORATE WHEN INSTALLED ON EXTERIOR WALL. HANG ORIENTATION: HORIZONTAL DESIGN: URBAN SKETCH CONTACT ANN RANK AT (407)491-1752 OR ARANK@MDCWALL.COM LOCATION: COMMUNITY, BREAKROOM LOWER CABINETS COLOR: URS265-106 FADED ANCHOR NOTES: CONTACT MEGHAN RAWLINS ENGER AT (407)832-5388 SIZE: 19.7' X 19.7" OR RAWLINM@WILSONART.COM TT TT -Ij 4. ALL MISCELLANEOUS GRILLES, PLATES, OR OTHER DEVICES SHALL BE PAINTED TO MATCH THE WALL OR CEILING IN WHICH THEY ARE INSTALLED, U.N.O. 5. PROVIDE TRANSITION STRIPS AT ALL FLOORING MATERIAL CHANGES. TRANSITIONS IN DOOR THRESHOLDS SHALL BE CENTERED DIRECTLY UNDER DOOR. FURNISH COLOR SAMPLES FOR REVIEW PRIOR TO INSTALLATION. 6. PROVIDE TO CAMPBELL + VAN DUSEN DESIGN STUDIO COLOR SAMPLES OF ALL FINISHES AND MATERIALS FOR VERIFICATION AND REVIEW PRIOR TO INSTALLATION. INSTALL PATTERN: ASHLAR FwV6] WALLCOVERING - 6 FURNISH Al 11C 3100, OF 5/o OVERAGE Cjr fALL /ALL k—k-IVEM11141-7 1'%IIILJ rL%_AJK11N%.7 WT1 WALL TILE I COMMUNITY LOCATION: AS INDICATED ON PLAN. DISTRIBUTOR: NATIONAL SOLUTIONS FPL2 PLASTIC LAMINATE - 2 FINISHES, NOT LESS THAN 10 YARDS OF EACH TYPE OF CARPET AND NOT LESS THAN NOTES: 90% OF OVERALL PATTERN WHEN USED WITH CPT5. INSTALL PER PATTERN: PAVE MANUFACTURER: WILSONART 20 SQUARE FEET OF EACH TYPE OF RESILIENT FLOORING. MANUFACTURER'S REQUIREMENTS. USE A MILLIKEN COLOR: MILLION DOLLAR BEIGE Y46303PV COLOR: CRISP LINEN 4942-38 MANUFACTURED/APPROVED ADHESIVE. INSTALL A TRANSITION STRIP AT ALL WIDTH: 54" FINISH: FINE VELVET FINISH 8. FLOORING INSTALLATION SHALL BE COORDINATED WITH OWNER REPRESENTATIVE. FLOORING TRANSITIONS. CONTACT ROSIE STERLING AT LOCATION: AS INDICATED ON PLAN HANG ORIENTATION: HORIZONTAL PRIOR NOTICE OF ANY EXISTING FIELD CONDITIONS THAT MAY POSE A PROBLEM ROSIE.STERLING@MILLIKEN.COM OR (407)580-7909 NOTES: MICROPERFORATE WHEN INSTALLED ON EXTERIOR WALL. LOCATION: COMUNITY & BREAK ROOM UPPER CABINETS FOR INSTALLATION SHALL BE GIVEN IN A TIMELY MANNER. CONTACT ANN RANK AT (407)491-1752 OR ARANK@MDCWALL.COM NOTES: CONTACT MEGHAN RAWLINS ENGER AT (407)832-5388 OR RAWLINM@WILSONART.COM 11. PRE -PLAN CARPET SEAMING SO AS TO PROVIDE UNIFORM DIRECTION OF PATTERN FLOOR TILE - I DISTRIBUTOR: TRINITY TILE WALLCOVERING - 7 Efl AND LAY OF PILE. LOCATION OF SEAMS SHALL BE CENTERED UNDER DOORS AND SERIES: SOCIAL DISTRIBUTOR: NATIONAL SOLUTIONS PLASTIC LAMINATE - 3 WITHOUT SEAMS IN THE DIRECTION OF TRAVEL. SUBMIT SEAMING DIAGRAM FOR PATTERN: PAVE MANUFACTURER: WILSONART REVIEW PRIOR TO PLACEMENT OF ORDER. COLOR: GRAY LAKE SIZE: 12" X 24" COLOR: WHITE GRASS Y46294PV COLOR: PORTICO TEAK 821 OK-28 WIDTH: 547 FINISH: GLOSS LINE FINISH WITH AEON 12. TEST CONCRETE SUBSTRATES FOR IRH (INTERNAL RELATIVE HUMIDITY) ACCORDING GROUT: MAPEI 02 PEWTER LOCATION: AS INDICATED ON PLAN HANG ORIENTATION: HORIZONTAL TO ASTM F 2170. CONFIRM MOISTURE CONTENT SUITABLE FOR INSTALLATION OF GROUT JOINT WIDTH: 1/8" INSTALL PATTERN: 1/3 OFFSET NOTES: CONTACT ANN RANK AT (407)491-1752 OR ARANK@MDCWALL.COM LOCATION: PROVIDER & HUDDLE FLOORING PER MANUFACTURERS RECOMMENDATIONS. NOTES: CONTACT MEGHAN RAWLINS ENGER AT (407)832-5388 WT2 WALL TILE 2 BREAKROOM LOCATION: RESTROOM FLOOR TILE AS NOTED ON PLAN OR RAWLINM@WILSONART.COM 13. MATCH EXISTING STOREFRONT SYSTEM. NOTES: SEAL GROUT. INSTALL A TRANSITION STRIP AT ALL FLOOR WALLCOVERING - 8 Fw­V8] TRANSITIONS. TO ORDER CONTACT JENNIFER HORNING AT (321) 231-2181 DISTRIBUTOR: NATIONAL SOLUTIONS OR JHORNING@TRINrrYSURFACES.COM PATTERN: PAVE QUARTZ SOLID SURFACE COUNTERTOP - 1 14. BUILD UP CARPET TO BE FLUSH WITH LVT. COLOR: GREAT LAKE Y47320PV MANUFACTURER: DALTILE FET11 VINYL SHEET I WIDTH: 54" COLOR: GOLDEN GATE OQ37 INTERIOR WALL AND CEILING FINISH REQUIREMENTS MANUFACTURER: SHAW CONTRACT LOCATION: AS INDICATED ON PLAN FINISH: POLISHED STYLE: VITALITY SHEET NOTES: CONTACT ANN RANK AT (407)491-1752 OR ARANK@MDCWALL.COM THICKNESS: 3 CM COLOR: RESTORE 73518 EDGE PROFILE: EASED EDGE SIZE: 6.58'X 65.94' LOCATION: COMMUNITY AND BREAKROOM COUNTERTOPS GROUP EXIT ENCLOSURES & CORRIDORS ROOMS & ENCLOSED LOCATION: AS INDICATED ON PLAN. NOTES: 2" CORNER FOR COUNTER TOPS EXIT PASSAGEWAYS SPACES NOTES: INSTALL PER MANUFACTURER'S REQUIREMENTS. INSTALL A TRANSITION STRIP AT ALL FLOORING TRANSITIONS. CONTACT VIRNA f I I BUSINESS B C C MITCHELL AT VIRNA.MITCHELL@SHAWCONTRACT.COM OR (407)405-0422. . . . . . . (PER FBC 2020 803.11) I /A4.1 CAMPBELL + VAN DUSEN ARCHITECTURE INTERIOR DESIGN www.CVDstudio.com CAMPBELL + VAN DUSEN Design Studio, LLC. 255 South Orange Avenue Suite # 1240 Orlando, Florida 32801 Phone: 407.930.6016 FL. Lic. No. AROO 16053 ARCHITECT OF RECORD FRANK W. CAMPBELL AIA FL LIC NO. AROO 16053 COPY OF THIS PLAN IS NOT VALID UNLESS SIGNED, SEALED AND DATED BY THE ARCHITECT OF RECORD COPY OF THIS PLAN IS NOT VALID UNLESS SIGNED, SEALED AND DATED BY THE ENGINEER OF RECORD I ILL z _j 0 F_ CL LU LLJ < > C) U-1 _j F_ (-) F_ - + Lo LU 2' w < --I 0 LJJ > () 10 1- 10:� C) U_j -'o Lo CL < 3�: rL_U4 r02 'CV12) CONSTRUCTION DOCUMENTS 03.24.2023 PRINCIPAL IN CHARGE F. CAMPBELL .................................................................... PROJECT MANAGER .M..T.O.R.RES ......................................................... ADVENT HEALTH WELL 65+ ZEPHYRHILLS 22-0328-01 FINISH PLAN LEGEND A4* 1 �Al �A2 1 14 ,j �A3 /S-A4 Y�A�5 L %-0) %.-0) %-90) %.-0) CLG 7 CLG CLG CLG CLG CLG 3- 0" L01 3- 0" 6" L001 1' 6" Le 0" e_ PL3 AS SOFFIT SOFFIT SOFFIT SOFFIT SOFFIT SOFFIT b AS 0 PROVIDE REMOVABLE AS 10 AS 10 AS, 10 AS ;0 WATERLINE CONNECTION NJ PROVIDE RECESSED PANEL ABOVE FRIDGES C14 -FOR WATER & ICE 04 0 N 0 0 N 0 N 0 7- z z z N LU LU ED CAMPBELL + VAN DUSEN 0 I:s C) U U I L\i ___s E II_ Is 11 b V 0 V 0 0 V 0 ARCHITECTURE INTERIOR DESIGN b I— F- F- %N 0 V- 2" V- 2" 1'- 2" 1'- 2" L 01 CD 00, C) e 1� L Kt1­t3.)tL) RECESSED RECESSED A 10 A 10 10 00 1 10 *1 10 I - 04 b 2'- 1 CT 04 WT2 OUTLET OUTLET 0 TLET 2'- 1 CT b 2'- 1 CT a 2'- 1 CT - 0 2'- 1 CT www.CVDstudio.com 10 of 10 '0 — 10 L01 rT- 04 10 -1 10 CAMPBELL + VAN DUSEN Design Studio, LLC. Qz] 255 South Orange Avenue Suite # 1240 L__j �w_ DW DW PW DW DW ILl — Phone: 407.930.6016 DW FL. Lic. No. AR001 6053 0 i0i AS DW INSULATE ALL J 0 0 b DW EXPOSED PIPES AND RECESSED HOT SURFACES 04 �,I OUTLET c� b" DW L-1.1w 1, 1 ammmmi!F41 I I TS TS S TS 7 jfv 3 1 1 3- 0" 1'- 6" � Y[ 6" 2'- 6" Y - 6" J# 2'- 0 2'- 0" BC r% 2'- 9'BC4 T% r% 2'- 0" BC 2'- 0" BC 2'- 0" BC lei 101 I imm Omni ELEVATION a BREAKROOM (S_A_1� SECTION @ BREAKROOM (S_-j�� SECTION BREAKROOM � �-A3 SECTION @ BREAKROOM (S_-A_4� SECTION a BREAKROOM (S-Ajr� SECTION @ BREAKROOM 1/211 = 1 1-091 �A5.0) 1/2" = V-0" �A&0) 1/2" = V-0" � A5.0 ) 1/2" = V-01" �A&0) 1/2" = V-0" �A5.0) 1/2" = V-0" PAINTED RED DASHED 11/�S-Dl LINE WITH WORDING ARCHITECT OF RECORD THAT READS "DO NOT "111�0 FRANK W. CAMPBELL AIA CLG CLG CLG STACK ABOVE THIS LINE' FL LIC NO. AROO 16053 COPY OF THIS PLAN IS NOT VALID UNLESS SIGNED, CLG :z L SEALED AND DATED BY THE ARCHITECT OF RECORD 2'- 0" 2'- 0" 2'- 0" 2'- 0" 1,01 19 0, 1'- 2" 01-10, 3- 0" 3- 0" 3- 0" 1'- 3" 2" or LO - LOP oF Ile J# of L01 J-1 NJ %1 2'- 01, 10 SOFFIT SOFFIT SOFFIT J N %I AS AS 7CLG AS AS AS AS A I AS Z_ /_ms cz=� cN 04 00 OD PL3 0" 6- 0 b z 0 AS Uj AS U PL3 CABINET NOTES: Y- 2" b �0 (BOXED NOTE NUMBERS ARE KEYED TO PLAN) O� 2'- 0" 0 C� �4 c� c� c� 4 le 40 2'- 0" CT 2'- 0" CT 2'- 0" CT 04 r, mi CABINET SUBCONTRACTOR SHALL REVIEW A COMPLETE SET OF DRAWINGS. oo, — e_ I AS AS QZ2 QZ2 #4 - -0 �0 S 7% M2 CABINET SUBCONTRACTOR SHALL BE RESPONSIBLE TO COORDINATE HIS WORK M3 BEFORE PROCEEDING WITH FABRICATION OF MILLWORK REQUIRED TO BE FITTED c� 1� SUPPORT 10 10 10 TO OTHER CONSTRUCTION, CABINET CONTRACTOR SHALL VERIFY FIELD BRACE SUPPORT -1 -1 m m DIMENSIONS AND PREPARE SHOP DRAWINGS/DETAILS AS REQUIRED FOR BRACE CN ACCURATE FIT. M4 SUBMIT CABINET SHOP DRAWINGS FOR REVIEW BY ARCHITECT AND COPY OF THIS PLAN IS NOT VALID UNLESS SIGNED, r% r% r% CONTRACTOR. VERIFY DRAWER DEPTH, CABINET DEPTH, SHELF SPACING, SINK SEALED AND DATED BY THE ENGINEER OF RECORD LOCATION, AND DOOR SIZES WITH ARCHITECT IF UNCLEAR. CAB MFR SHALL ELEVATION @ CARE ELEVATION @ CARE SECTION @ CARE OBTAIN CONTRACTOR OR CLIENT REVIEW OF CABINET DRAWINGS BEFORE COORDINATORS rc_"� COORDINATORS COORDINATORS ELEVATION BIO ECTION BIO FABRICATION OF CABINETRY BEGINS. 1/211 1 1-011 1/211 1 '-Oil 1/211 1 '-Oil �.O 1/211 1 1-011 /211 if -Oil M5 ALL CORNERS OF PLASTIC LAMINATE TOPS, DOORS, AND DRAWERS SHALL BE FILED SLIGHTLY TO ELIMINATE ALL SHARP CORNERS. rS - Ek2- rS-Et"'16, rS--'E4 A� M7 PROVIDE WIRE WAY HOLES WITH 2" GROMMETS AT FRONT DESK AND WORK AREAS THAT HAVE OPEN SPACE BELOW COUNTER TOP. LOCATE ON SITE AS PER CLG CLG CLG CLG CLIENT'S REQUIREMENTS. M8 ASSEMBLE CABINETS SO THAT THERE ARE NO GAPS ANYWHERE THAT THE TOEKICK, CABINET, AND WALL MEET ONE ANOTHER. THIS INCLUDES GAP OFTEN 2'- 0" 4'- 0" 2'- a' FOUND IN UNDERSIDE OF BASE CABINET WHERE THE CABINET MEETS THE WALL. U_ _1p %J %J M9 ADJUST DOORS AND DRAWERS TO EQUALIZE GAPS. MAX GAP 3/32". M10 NO GAPS VER 3 'ANYWHER IN INSTALLED CABINET W RK. AULK ALL S046 SOFFIT SOFFIT SOFFIT GAPS OF ABIN A -M A . Os :�o 10 10 10 M12 DEPTH OF UPPER CABINETS VARIES. SEE ALL CABINET SECTION DETAILS FOR -1 -1 -1 0 0 CN REQUIRED CLEAR DIMENSIONS FOR UPPER CABINETS. 0- i CL Uj U-1 UJI M13 SET BACK SPLASH IN BED OF SEALANT. r-4 0 CABINET ABBREVIATIONS: T— L CIS —Az I Li b 0 0 V b 0 1'- 2" z M14 SET BASE IN SEALANT. V) < (11) > 40 op Of AS ADJUSTABLE SHELVES LIJ Lj_j _j b b 2'- 1" CT BC BASE CABINET M15 THE FLORIDA ACCESSIBILITY CODE REQUIRES MANEUVERABILITY SPACE 0 01 2'- 1" CT ;0 01 2'- 1 CT 10 c� OF BD BAFFLE DIVIDER 04 7 ADJACENT TO LATCH SIDE OF DOORS. IF CABINETS ARE LOCATED ADJACENT -- + T _j I Lr) CT COUNTER TOP U < BS BACK SPLASH TO DOORS, A CLEAR MIN. SPACE OF 18" AT PULL SIDE AND 1Z'AT PUSH SIDE (OF QZI DOOR) SHALL BE MAINTAINED IF THE ADJACENT DOOR HAS A LATCH - L DW DRAWER Uj Ljj �w- FD DRAWER FOR HANGING FILES QUESTIONS. PW C) Uj 0 FS FIXED SHELVES ID INSIDE DIMENSION Iry LU 00 cy) KS KNEE SPACE M16 ALL EXPOSED SURFACES AND EDGES OF PLYWOOD AND MDF SHALL BE < 3: r__4 r_1 cy) INSULATE ALL COVERED WITH THE SPECIFIED PLASTIC LAMINATE. EXPOSED PIPES AND OS OPEN SHELF 04 HOT SURFACES PG PLASTIC GROMMET FOR WIRE ACCESS M19 SINK BASE CABINETS: SINK BASE CABINETS SHALL BE SELF CONTAINED CABINETS. L121 p 11 PW PULL-OUT WASTE (NOT OPEN TO ADJACENT CABINETS.) ==7 SH SHELF/SHELVES CONSTRUCTION DOCUMENTS TS 'S TS SP SINK PANEL ID 0 M20 EXPOSED CORNERS OF COUNTER TOPS SHALL HAVE A MIN. 2" RADIUS. 2'- 0" 2'- 6" 1' - 6" 2'- 0" 2'- 0" BC 2'- 0" BC 2'- 0" TS TOE SPACE 4" TYP. UC UPPER CABINET 4 7 01 101 4 M21 CABINET SUBCONTRACTOR SHALL VERIFY SINK SIZE AND LOCATION AND 03.24.2023 COORDINATE CABINETS. NOTIFY ARCHITECT IF QUESTIONS. ELEVATION COMMUNITY (S---E-2'� SECTION @ COMMUNITY (S_-­E'3� SECTION @ COMMUNITY /6-_E_4� SECTION @ COMMUNITY M23 THERE SHALL BE NO STILES OR DIVIDERS BEHIND OPENING EDGES OF ANY PAIR 1/211 1 1-011 1/2" 1 1-011 1/2" 1 1-01f A5.0 1/2" V-101" OF DOORS. NO. DATE DESCRIPTION M25 ALL EXPOSED ENDS OF 4" BACKSPLASHES ARE TO HAVE 2" RADIUS. M29 PROVIDE MIN. 5 1/2" X 1/2" FIRE -RETARDANT -TREATED WOOD BLOCKING @ �O DASHED PAINTED RED DASHED MOUNTING LOCATIONS OF ALL CABINETS AND CABINET BRACES. VERIFY SIZE PA NTED RED AND LOCATION OF THIS BLOCKING WITH CABINET INSTALLATION LINE WITH WORDING LINE WITH WORDING THAT READS "DO NOT THAT READS "DO NOT RECOMMENDATIONS OR NEEDS. COUNTERS WITHOUT BASE CABINETS THAT ARE CLG STACK ABOVE THIS LINE' STACK ABOVE THIS LINE' SUPPORTED BY A BRACE SHALL SUPPORT A MINIMUM OF 250 LBS. M30 NO PORTION OF COUNTERTOP OR SINK SHALL BE HIGHER THAN 34" PER CLG 0 2� CLG '0 2� FA C2020 203.9, 227., 106.5, 902.3. CABINETS: MATERIAL AND HARDWARE: PRINCIPAL IN CHARGE SOFFIT ---- - — — — - — — — — — — — — — — — — — — — — — — - — — — — — — — — - — — — — — — — — — — — TOPS 3/4'ABX PLYWOOD F. CAMPBELL . ..... .. ...... 2'- 0" c� c� OF 2'- 011 DOORS 3/4" ABX PLYWOOD P . R . OJECT . MA . NAGER ..... ...................... ......... ........... do ;m_ - DRAWER FRONTS 3/4" ABX PLYWOOD M. TORRES AS AS AS BACK SPLASH 5/8" ABX PLYWOOD .... I ............................................................... VN ------ BASE A L 2 1 -01, z 4- 2'- 0" SHELVES 3/4" ABX PLYWOOD Z Of- oo, =2 ;i OTHER 3/4" ABX PLYWOOD LLI U 2'- 0" CT AS AS z z AS ADVENT HEALTH c� __j --I A 0 [U [_U PLASTIC LAMINATE: b WELL 65+ 2'- 0" U U 2' -01, ALL EXPOSED SURFACES AND EDGES OF PLYWOOD AND MDF SHALL BE COVERED 0 0 0# z WITH PLASTIC LAMINATE. GRADE: PREMIUM. COLOR: SELECTED BY CLIENT. ZEPHYRHILLS Z'DIA c� b AS GROMMET �0 bo AS AS c� c� QZ2 PLASTIC LAMINATE FOR HORIZONTAL SURFACES: 0.050" THICK, GENERAL PURPOSE 11 z TYPE D (HIGH-PRESSURE). 2'- 0 2'- 0" �0 bv- ;_0 10 22-0328-01 As AS AS (HIGH-PRESSURE). 2 2'- 0" 01, `t SUPPORT — 1- _. I oo, CABINET HARDWARE: BRACE Mis I Jo - - J# DRAWER GUIDES FULL EXTENSION - HEAVY DUTY AS AS AS KNEE DRAWERS K & V #1428 MILLWORK 0 UTILITY DRAWERS K & V # 1429 ; , FILE DRAWERS K & V #1460 LL %, � � _% -,1 .1% - HINGES CONCEALED STANLEY # 1588 OR BLUM # 95 % N N N M5580 ADJUSTABLE SHELVES I" INCREMENT HOLES ELEVATION @ PROVIDER SECTION @ PROVIDER WORK PULLS 4' WIRE PULLS (NICKEL FINISH) U.N.C. WORKROOM �S­- �Fl R 0 0 M �'�G ELEVATION @ STORAGE 2 H � ELEVATION @ STORAGE 2 1/2" = 1 1-011 A5.0 1/211 = 11-011 k\��o 1/211 = 1 '-Oil k\,� �-o 1/21' = 11-011 A5.0 A I N NJ CLG 01 7- 6" SOFFIT 10 01 01 01 k 10 17 V� SZ 2' - 0" CT 0 6' - 0" 6' - 0" 2' - 0" CT ZD QZ2 QZ2 c:) zo PRINTER/COPIER SUPPORT OPEN KNEE F-1 F__1 SHRED BIN OPEN KNEE SUPPORT A SPACE OC3 0=2 SPACE BRACE 0=1 0= ELEVATION 0— HUDDLE ROOM 1/211 = 11-011 CLG -1 Eli If 2'- 0" CT 01 - QZ2 UPPORT BRACE L S 6 OPEN KNEE SPACE c� b /6'- 0" SOFFIT 2' - CY' CT QZ2 b b Ifl ffl'�OPEN KNEE SPACE SUPPORT BRACE r% F% ELEVATION 0 HUDDLE ROOM 1/211 = 1 1-011 18" 'ri -rl I (B - �2 BRACE DETAILS SCALE: I" - 1'-0'! 20" 10 .or of CABINET ABBREVIATIONS: AS ADJUSTABLE SHELVES BC BASE CABINET BD BAFFLE DIVIDER BS BACK SPLASH CT COUNTER TOP DW DRAWER FD DRAWER FOR HANGING FILES FS FIXED SHELVES ID INSIDE DIMENSION KS KNEE SPACE OS OPEN SHELF PG PLASTIC GROMMET FOR WIRE ACCESS PW PULL-OUT WASTE SH SHELF/SHELVES SP SINK PANEL TS TOE SPACE 4" TYP. UC UPPER CABINET SECTION 1/2" = 1 1-011 CLG SOFFIT PRINTER/COPIER HUDDLE AS C14 0 Uj C) 0 b ELEVATION @ HUDDLE ROOM 1/211 = 1 1-011 I CLG Lo (y) SOFFIT 2'- 0" CT 9'- 6" 01 9'- 6" 2'- 0" CT QZ2 10 - (14 QZ2 SUPPORT BRACE A F2 OPEN KNEN Ifl SPACE - OPEN KNFFEl Ifl SPACE E OPEN KNEE SPACE OPEN KNEE SPACE - SUPPORT BRACE ry J_ E I j Iml Im E F% r% r% ELEVATION @ HUDDLE ROOM 1/211 = 1 #-Oil SECTION 1/211 = 11-011 HUDDLE CAMPBELL +VAN DUSEN ARCHITECTURE INTERIOR DESIGN www.CVDstudio.com CAMPBELL + VAN DUSEN Design Studio, LLC. 255 South Orange Avenue Suite # 1240 Orlando, Florida 32801 Phone: 407.930.6016 ARCHITECT OF RECORD FRANK W. CAMPBELL AIA FL LIC NO. AR001 6053 COPY OF THIS PLAN IS NOT VALID UNLESS SIGNED, SEALED AND DATED BY THE ARCHITECT OF RECORD COPY OF THIS PLAN IS NOT VALID UNLESS SIGNED, SEALED AND DATED BY THE ENGINEER OF RECORD __j U_ 0 F— 0— q= = LLJ Qe II`_ r_4 < V) > U-i L.0 _j + Lx-) __j :Z 14C) < LU LLj > 0 C) LIJ 0_ 1-0 11q_ '0 Lr) LLJ -4 00 (y) (y) CONSTRUCTION DOCUMENTS 03.24.2023 DESCRIPTION PRINCIPAL IN CHARGE F. CAMPBELL ........... ........................................................ PROJECT MANAGER M. TORRES .................................................................... ADVENT HEALTH WELL 65+ ZEPHYRHILLS 22-0328-01 MILLWORK A5.1 MECHANICAL GENERAL NOTES FURNISH ALL LABOR, MATERIALS, SERVICES, EQUIPMENT AND APPLIANCES REQUIRED XISTING MECHANICAL SYSTEMS INCLUDING HEATING, VENTILATION, AIR CONDITIONING, AND MISCELLANEOUS SYSTEMS AS INDICATED ON THE DESIGN DRAWINGS AND AS OUTLINED IN THE SPECIFICATIONS. THE ENTIRE SYSTEM AND ALL COMPONENTS SHALL HEREIN MEET ALL STATE, COUNTY, DINANCES IN EVERY RESPECT. MECHANICAL CONTRACTOR SHALL OBTAIN ALL PERMITS AND PAY ALL FEES REQUIRED FOR HIS PORTION OF THE WORK. REFER TO DRAWINGS FOR NEW AND REUSED EXISTING EQUIPMENT. ALL NEW EQUIPMENT, ETC. SHALL BE OF THE BEST QUALITY, FREE OF DEFECTS, AS SHOWN ON THE DRAWINGS, AND AS INDICATED IN THE SPECIFICATIONS. ALL SYSTEMS SHALL BE FABRICATED AND INSTALLED IN A NEAT AND PROFESSIONAL MANNER WITH THE COORDINATION OF ALL INVOLVED TRADES TO AVOID INTERFERENCE OF COORDINATION. NO ALLOWANCES WILL BE MADE FOR REWORK DUE TO COORDINATION DIFFICULTIES OR INTERFERENCE BETWEEN INVOLVED TRADES. EXISTING SYSTEMS SHOWN ON THIS PLAN ARE BASED ON FIELD OBSERVATIONS AND AVAILABLE RECORD DRAWINGS. THIS INFORMATION IS PARTIALLY UNVERIFIED. CONTRACTOR ACCEPTS RESPONSIBILITY FOR FIELD VERIFICATION AND INVESTIGATION PRIOR TO SUBMITTING BID. DO NOT SCALE THESE PLANS. MECHANICAL CONTRACTOR SHALL INCLUDE IN HIS BASE BID THE COST OF PREPARING A FINAL TEST AND BALANCE REPORT. TEST AND BALANCE SHALL BE BY T&B COMPANY CERTIFIED BY AABC OR NEBB ONLY. EXISTING AIR QUANTITY SHALL BE REBALANCED TO AIR QUANTITY NOTED ON PLAN. TEST & BALANCE CONTRACTOR MAY NOT SHUT OFF OTHER PORTIONS OF THE FLOOR IN ORDER TO OBTAIN SUFFICIENT STATIC PRESSURE TO COMPLETE THEIR BALANCE FOR THIS SPACE. THIS SPACE MUST BE SYMBIOTIC WITH THE BALANCE OF THE REST OF THE FLOOR IN A FULLY OCCUPIED MANNER. LOW PRESSURE DUCTWORK SHALL BE GALVANIZED STEEL OF GAUGES CONFORMING TO LATEST EDITION OF SMACNA STANDARDS BASED ON 2* W.G. PRESSURE UNLESS SPECIFICALLY NOTED OTHERWISE ON THE DRAWINGS. THE GALVANIZED DUCT COATING IS TO BE G-90. JOHNS MANVILLE SUPERDUCT IS ACCEPTABLE FOR LOW PRESSURE T ONLY. ALTERNATE PRICING: PROVIDE AN ALTERNATE PRICE TO USE JOHNS MANVILLE FR-800 (SUPERDUCT) IN LIEU OF SHEET METAL DUCT TWORK. THE R-VALUE OF THE INSULATION SHALL MATCH INSULATION VALUES LISTED BELOW FOR SHEET METAL DUCT INSULATION. ALL JOINTS SHALL BE SEALED WITH GLASS FABRIC AND MASTIC. FLEXIBLE DUCTWORK SHALL BE ACOUSTICAL LOW PRESSURE TYPE WITH INTERIOR LINER, METAL HELIX, 1" FIBERGLASS INSULATION, AND COPOLYMER SEAMLESS OUTSIDE SLEEVE. THE ENTIRE FLEXIBLE DUCT ASSEMBLY SHALL BE LISTED IN ACCORDANCE WITH UL-181 CLASS 1 AIR DUCT MATERIAL THE MAXIMUM LENGTH OF ANY FLEX DUCT SHALL BE 8'-Om. THIS APPLIES TO NEW FLEXIBLE DUCTWORK ONLY. EXISTING FLEXIBLE DUCTWORK EXCEEDING EIGHT FEET IN LENGTH MAY REMAIN (AT BUILDING OWNER'S DISCRETION) PROVIDED IT IS PROPERLY HUNG AND SUPPORTED PER ASHRAE RECOMMENDATIONS AND ALLOWS FOR UNRESTRICTED AIRFLOW. EXCESSIVE NOISE OR INSUFFICIENT AIRFLOW SHALL BE CAUSE FOR REPLACEMENT OF FLEXIBLE DUCTWORK TO COMPLY WITH THE ABOVE MENTIONED LENGTH RESTRICTIONS. REPLACE EXISTING FLEX DUCT WHICH EXCEEDS 8'-Om IN LENGTH WITH ROUND SHEET METAL DUCT. "DAISY CHAIN" OF MORE THAN ONE 8'-O" SECTION OF FLEX WITH RIGID DUCT IN BETWEEN IS NOT ACCEPTABLE. ALL DIMENSIONS ARE INSIDE NET FREE AREA. NEW THERMOSTATS SHALL BE INSTALLED 48" ABOVE FINISHED FLOOR. MASTER THERMOSTATS FOR EACH AHU AND VAV SHALL BE LOCATED IN REMOTE LOCATION DICTATED BY TENANT. CONFIRM LOCATION. EACH THERMOSTAT SHOWN ON PLAN IS TO BE A SENSOR THAT REPORTS TO THE CONTROL SYSTEM. DIFFUSER, REGISTER AND GRILLE INSTALLATIONS SHALL BE COORDINATED WITH OTHER TRADES. EXISTING DUCTWORK SHOWN IS FOR REFERENCE ONLY. VERIFY EXISTING LOCATIONS SIZE OF DUCT RUNOUT, FLEX AND SPIN -IN TAP SHALL EQUAL DIFFUSER NECK SIZE. ALL DUCT INSULATION SHALL COMPLY WITH FLORIDA MODEL ENERGY EFFICIENCY CODE. SHEETMETAL DUCT WILL INCLUDE 1-1/2- DUCT WRAP. DUCTBOARD SHALL BE JOHNS MANVILLE FR-800, l-, R-4.2 SUPERDUCT MINIMUM. THIS APPLIES TO NEW DUCTWORK ONLY, EXISTING UNINSULATED SHALL REMAIN AS IS UNLESS OTHERWISE REQUIRED BY THE AUTHORITY HAVING JURISDICTION. ALL EXHAUST AND OUTSIDE AIR DUCTWORK SHALL BE SHEETMETAL THERE ARE NO FIRE RATED CEILINGS. ALL DUCTBOARD DUCT AND DUCT INSULATION SHALL BE SEALED WITH GLASS FABRIC AND MASTIC. SEE PLANS FOR ROUTING OF CONDENSATE. NO CONDENSATE SHALL BE ROUTED TO HARD SURFACES. PIPE TO STORM DRAIN, DRYWELL OR GRASSY AREA AS INDICATED ON PLANS, OR ALLOWED BY LOCAL AUTHORITY. MENDED SERVICE CLEARANCE FOR ALL EQUIPMENT SHALL BE MAINTAINED. ALL DUCTWORK SHALL BE SUPPORTED IN STRICT COMPLIANCE WITH SMACNA OR FLORIDA MODEL ENERGY EFFICIENCY CODES WHICHEVER IS STRICTER. PRIOR TO COMMENCEMENT OF DEMOLITION, CONTRACTOR SHALL INSPECT ALL SYSTEMS AND EQUIPMENT WITHIN THE AREA OF WORK TO DETERMINE FITNESS FOR OPERATION. CONTRACTOR SHALL PROVIDE A FULLY OPERATIONAL FINISHED SYSTEM AS DESCRIBED. PATCH AND MAKE GOOD ALL LEAKS IN EXISTING DUCT. SEAL LEAKS WITH MASTIC. REPAIR AS REQUIRED TO RESTORE VAPOR BARRIER AND INSULATION SYSTEM. CONTRACTOR SHALL INSPECT MECHANICAL EQUIPMENT INCLUDING, BUT NOT LIMITED TO, FAN POWERED BOXES, VAVS, FANS, SUPPLEMENT HVAC EQUIPMENT AND RELATED BEING REUSED IN THE RENOVATION OF THE SPACE. MECHANICAL CONTRACTOR SHALL LIST IN WRITING TO THE BUILDING OWNER ALL ITEMS FOUND TO BE INOPERABLE, DAMAGED, OR BEYOND REPAIR AND PROVIDE LINE ITEM LACEMENT. CONTRACTOR SHALL NOT PROCEED WITH REPAIRS/REPLACEMENT UNTIL RECEIVING WRITTEN DIRECTION FROM THE BUILDING OWNER. EXHAUST FAN SHALL BE PROVIDED WITH BACKDRAFT DAMPER AND BLADE SEAL. CLEAN EVAPORATOR COIL(S) AND DRAIN PAN(S), LUBRICATE MOTOR(S) AND PROVIDE NEW SET OF FARR FILTERS FOR EACH UNIT. CONFIRM OPERATION OF EXISTING SMOKE DETECTORS AND THAT ALL SMOKE ATH ASSOCIATED AHU. DETECTORS ARE INTERCONNECTED V MECHANICAL CONTRACTOR SHALL EXAMINE ARCHITECTURAL, STRUCTURAL, ELECTRICAL, PLUMBING AND FIRE PROTECTION DRAWINGS FOR ESTIMATING AND CONSTRUC11ON OF THIS PROJECT. SUBMISSION OF A PROPOSAL SHALL BE CONSTRUED AS EVIDENCE THAT SUCH EXAMINATION HAS BEEN MADE AND LATER CLAIMS FOR LABOR, EQUIPMENT OR MATERIALS REQUIRED FOR ANY CORREC11ONS REQUIRED DUE TO CONFLICTS WITH OTHER TRADES WILL NOT BE RECOGNIZED. ALL DUCTWORK AND PIPING NOT OPERATIONAL DURING CONSTRUCTION SHALL BE CAPPED UNTIL FINAL CONNECTIONS ARE MADE. ALL RETURN GRILLES ON ALL HVAC SYSTEMS BEING OPERATED DURING CONSTRUCTION SHALL HAVE FILTER MEDIA COVERING RETURN AIR OPENINGS TO PRE-FiLTER AIR. FILTER MEDIA TO BE REMOVED AT THE COMPLE11ON OF CONSTRUCTION. INSULATION USED WITHIN THIS PROJECT DESIGN MEETS THE CRITERIA AS PRESCRIBED IN 2020 FMC SECTIONS 604.1 THROUGH 604.13. 1 MECHANICAL CONTRACTOR SHALL PROVIDE ALL CONTROLS REQUIRED TO OPERATE THE MECHANICAL SYSTEM INSTALLED. CONTROLS SHALL MATCH BASE BUILDING STANDARDS AND SHALL BE INSTALLED IN ACCORDANCE WITH THE GENERAL PRACTICES OF THE BUILDING. ALL CONTROLS SHALL BE COORDINATED WITH AND AGREED TO BY THE BUILDING ENGINEER PRIOR TO PURCHASE AND INSTALLATION. NEW EQUIPMENT SHALL BE CONNECTED TO EXISTING BUILDING MANAGEMENT SYSTEM NTH UPGRADES APHICS. BUILDING OYMER'S SPECIFICATIONS AND CRITERIA FOR MATERIALS AND PROCEDURES SHALL GOVERN MEN IN CONFLICT VATH MEMANICAL SPECFICATIONS AND NOTES. IT IS THE CON17RACTOR'S RESPONSOLITY TO OBTAIN A COPY OF THE OWNEWS SPECIFICATIONS PRIOR TO SUBMITTING BID. MECHANICAL DRAWING INDEX SHEE7 If SHFJ=7 1)r=SCFdFTM MO.1 MECHANICAL SPECIFICATIONS M1.0 MECHANICAL RENOVATION PLAN M2.1 MECHANICAL RENOVA11ON PLAN - ROOF I M4.0 MECHANICAL DETAILS I M5.0 I MECHANICAL SCHEDULES I MECHANICAL SPECIFICATIONS GENERAL MECHANICAL REQUIREMENTS DIVISION 23 SCOPE OF WORK WORK SHALL INCLUDE BUT NOT BE LIMITED TO THE FOLLOWING: PROVIDE ALL LABOR, MATERIALS, SERVICES, EQUIPMENT AND APPLIANCES REQUIRED FOR THE FABRICATION, INSTALLATION, AND/CIR RENOVATION OF MECHANICAL SYSTEMS INCLUDING HEATING, VENTILATING, AIR COND1110NING AND MISCELLANEOUS SYSTEMS AS INDICATED ON THE DESIGN DRAWINGS AND AS OUTLINED IN THESE SPECIFICATIONS. RELATED WORK SPECIFI REFER TO ELECTRICAL SPECIFICATION (DIV. 26) FOR ELECTRICAL WORK TO BE DONE IN CONJUNCTION WITH THE MECHANICAL WORK. THIS CONTRACTOR IS RESPONSIBLE FOR ALL CONDUIT, WRING, JUNCTION BOXES, ETC., REQUIRED FOR HVAC CONTROLS. INSTALL DUCT SMOKE DETECTOR FURNISHED BY DIVISION 26 IN SUPPLY AIR DUCTS OF AIR HANDLING UNITS EXCEEDING 2000 CFM AND MERE INDICATED ON DRAWINGS. DETECTOR TO SHUT UNIT DOWN WHEN ACTIVATED. EQUIPMENT AND DESIGN OF SYSTEMS INDICATED ON THE DESIGN DRAWINGS AND WITHIN THESE SPECIFICATIONS SHALL BE CONSIDERED AS SPECIFIED STANDARD OF QUALITY. NO SUBSTITUTIONS SHALL BE MADE WITHOUT PRIOR WRITTEN APPROVAL OF THE ENGINEER. ANY DEVIATION FROM SPECIFIED EQUIPMENT THAT AFFECTS THE ELECTRICAL REQUIREMENTS SHALL BE COORDINATED BY THE MECHANICAL CONTRACTOR AND EQUIPMENT VENDOR WITH THE ELECTRICAL CONTRACTOR PRIOR TO SUBMITTING BIDS. FAILURE OF MECHANICAL CONTRACTOR AND VENDOR TO DO SO WILL NOT BE CAUSE FOR CHANGE OF BID AT A LATER TIME. IT WILL NOT BE THE RESPONSIBILITY OF THE ELECTRICIAN TO COORDINATE REVISED ELECTRICAL REQUIREMENTS DUE TO EQUIPMENT CHANGES INITIATED BY THE MECHANICAL CONTRACTOR AND VENDOR. IN ADDITION, THE MECHANICAL CONTRACTOR SHALL BE FINANCIALLY RESPONSIBLE FOR ANY AND ALL CHANGES TO ENGINEERING PLANS REQUIRED BY AUTHORITY HAVING JURISDICTION. - 2020 FLORIDA BUILDING CODE (SEVENTH EDITION) - MECHANICAL - 2020 FLORIDA BUILDING CODE (SEVENTH EDITION) - EXISTING BUILDING - 2020 FLORIDA BUILDING CODE (SEVENTH EDITION) - ENERGY CONSERVATION - NFPA 90A, 2018 EDITION - NFPA 72, 2016 EDITION (TO COVER THE AIR DUCT DETECTOR) - FLORIDA FIRE PREVENTION CODE (FFPC), SEVENTH EDITION THE CONTRACTOR SHALL OBTAIN ALL REQUIRED PERMITS, INSPECTIONS AND PAY ALL FEES. =61 llll"� REFER TO PLANS FOR NEW AND REUSED EXISTING EQUIPMENT. ALL NEW EQUIPMENT, ETC., SHALL BE AS SPECIFIED, FREE OF DEFECTS, AS SHOWN ON THE DRAWINGS, AND AS INDICATED IN THESE SPECIFICATIONS. ALL ELECTRICALLY POWERED EQUIPMENT SHALL BE U.L OR E.T.L. LISTED. WORKMANSHIP ALL MATERIALS SHALL BE FABRICATED AND INSTALLED IN A NEAT AND WORKMANLIKE MANNER WITH THE COORDINATION OF ALL INVOLVED TRADES TO AVOID INTERFERENCES OF COORDINATION. NO ALLOWANCES WILL BE MADE FOR ATION DIFFICULTIES OR INTERFERENCES BETWEEN INVOLVED TRADES. MECHANICAL CONTRACTOR SHALL DAILY REMOVE REFUSE AND DEBRIS ACCUMULATING STRUC11ON AND PRIOR TO ACCEPTANCE OF THIS WORK. LEAVE THE PREMISES BROOM CLEAN INSOFAR AS AFFECTED BY MECHANICAL WORK. ALL DUCTWORK AND PIPING NOT OPERATIONAL DURING CONSTRUCTION SHALL BE CAPPED UNTIL FINAL CONNECTIONS ARE MADE. ALL RETURN GRILLES ON ALL HVAC SYSTEMS BEING OPERATED DURING CONSTRUCTION SHALL HAVE FILTER MEDIA COVERING RETURN AIR OPENINGS TO PRE -FILTER AIR. FILTER MEDIA TO BE REMOVED AT THE COMPLETION OF CONSTRUCTION. SHOP DRAWINGS AND SUBMITTALS SUBMIT FOR ENGINEER'S APPROVAL, A MINIMUM OF 2 PRINTED COPIES OF SHOP DRAWINGS AND MANUFACTURER'S DATA FOR ALL NEW EQUIPMENT AND ACCESSORIES PRIOR TO PURCHASE AND/OR FABRICATION. SHOP DRAWINGS FOR EQUIPMENT REQUIRING ELECTRIC POWER OR CONTROL WRING CONNECTIONS SHALL INCLUDE COMPLETE WRING DIAGRAMS. SUBMITTAL PACKAGE FOR HVAC EQUIPMENT SHALL INCLUDE A COPY OF THE CERTIFICATION OF PROPOSED TEST AND BALANCE SUBCONTRACTOR. THE TEST AND HALL BE CERTIFIED BY ASSOCIATED AIR BALANCE COUNCIL (AABC) OR NATIONAL ENVIRONMENTAL BALANCING BUREAU (NEBB). HVAC SUBMITTALS WILL NOT BE REVIEWED WITHOUT TEST AND BALANCE CERTIFICATION DOCUMENTATION. QUALIFICATIONS OF MULTIPLE TEST AND BALANCE CONTRACTORS ARE ACCEPTABLE (TO ACCOMPLISH COMPETITIVE BIDDING OF WORK). CONTRACTOR SHALL SUBMIT FOR APPROVAL THE PROPOSED TEST AND BALANCE CONTRACTOR AT THE TIME OF BID. WHEN PROVIDED, THE DUCTWORK SHOP DRAWINGS WILL ONLY BE REVIEWED FOR COMPLIANCE WITH THE DRAWINGS AND SPECIFICATIONS. THE DUCTWORK SHOP DRAWINGS WILL NOT BE CHECKED FOR COORDINATION WITH OTHER TRADES OR BUILDINGS STRUCTURE. IT IS THE RESPONSIBILITY OF THE CONTRACTORS TO COORDINATE AND VERIFY ROUTING AND EXACT LOCATION OF SYSTEM COMPONENTS. �V:cfllivlmlml MIN& VIDE THE ENGINEER TWO (2) SETS OF COMPLETE HVAC RECORD DRAWINGS AT THE TIME OF SUBSTANTIAL COMPLETION. RECORD DRAWINGS IN PDF FORMAT, AUTOCAD [RELEASE 2016 OR NEWER] OR AUTODESK REMT [RELEASE 2014 OR NEWER] SHALL BE PROVIDED ON A CD. RECORD DRAWINGS SHALL CONSIST OF AN ACCURATE AS -BUILT RECORD OF THE INSTALLED WORK. PROJECT WILL NOT BE COMPLETE UNTIL ACCURATE RECORD DRAWINGS ARE DELIVERED. EXECUTION COORDINATE AND SCHEDULE THE WORK WITH THE OWNER TO MINIMIZE DISRUPTIONS TO THE NORMAL OPERATIONS AT THE BUILDING. ALL LOCATIONS OF EQUIPMENT, DUCTWORK, PIPING, ETC., INDICATED ON THE DRAWINGS IS DIAGRAMMATIC AND SHALL BE FOLLOWED AS CLOSELY AS POSSIBLE TO THE PLANS SUBJECT TO BUILDING CONSTRUCTION AND INTERFERENCES WITH OTHER TRADES. ALL WORK SHALL BE INSTALLED TO ENSURE MAXIMUM HEADROOM, BALANCED OPERATION AND SUITABLE AESTHETIC APPEARANCE. CONTRACTOR IS RESPONSIBLE FOR MY FIELD MEASUREMENTS REQUIRED TO PROVIDE AN APPROVED AND FUNCTIONAL INSTALLATION. COORDINATE WITH OTHER TRADES AND FIELD -VERIFY EXISTING CONDITIONS FOR EXACT TI OF SYSTEMS. PROVIDE OFFSETS, TRANSITIONS AND ADAPTORS AS REQUIRED. QUIRED FOR A COMPLETE INSTALLATION ARE SHOWN ON THESE DRAWINGS. REFER TO EQUIPMENT INSTALLATION INSTRUCTION, SCHEDULES AND APPLICABLE CODES FOR ADDITIONAL INFORMATION, INCLUDING REQUIRED CONNECTION LOCATIONS, TYPES AND SIZES. PERFORM ALL WORK NECESSARY TO PREPARE THE STRUCTURE FOR THE INSTALLATION OF THE WORK. ALL HOLES, OPENINGS AND DAMAGED MATERIALS CREATED DURING CONSTRUCTION SHALL BE REPAIRED AND FINISHED BY EXPERIENCED WORKMEN. PROVIDE ALL PENETRATIONS REQUIRED TO COMPLETE INSTALLATION AND REMOVAL OF WORK (MAINTAIN FIRE RATING OF EXISTING STRUCTURE). ALL PENETRATIONS SHALL BE PATCHED AND FINISHED TO MATCH SURROUNDING SURFACES AND FINISHES. ALL PENETRATIONS SHALL BE SLEEVED AND SEALED SO AS TO BE WATER AND AIR TIGHT. CLEANING, TESTING AND ADJUSTING: THE MECHANICAL CONTRACTOR, AT HIS EXPENSE, SHALL CLEAN, REPAIR, ADJUST, CHECK, BALANCE, AND PLACE IN SERVICE THE VARIOUS SYSTEMS HEREIN SPECIFIED WITH THOR RESPECTIVE EQUIPMENT, ACCESSORIES AND PIPING. HE SHALL FURNISH ALL LABOR, MATERIALS, EQUIPMENT, AND TOOLS REQUIRED FOR PERFORMANCE TESTS REQUIRED BY THESE SPECIFICATIONS AND BY THE GOVERNING AUTHORITIES. NO WORK SHALL BE COVERED OR CONCEALED UN11L PROPERLY INSPECTED AND TESTED. EXCAVATION AND BACKFILL: PROVIDE ALL EXCAVATION AND TRENCHING TO THE CORRECT ELEVATIONS, FOR THE INSTALLATION OF ALL PIPING, VALVE, VALVE PITS AND FOUNDATIONS INCLUDED UNDER THIS DIVISION OF THE WORK. PROVIDE ALL BACKFILL AND COMPACTION IN STRICT ACCORDANCE WITH THE EXCAVATION AND BACKFILL SECTION OF DIVISION 1 SPECIFICATIONS. TESTING: RILY PLUGGING ALL OUTLETS AND FILLING THE SYSTEM NTH WATER TO THE LEVEL OF THE HIGHEST VENT STACK. THE SYSTEM MUST BE INSPECTED AND ALL LEAKS REPAIRED AND THE TEST REPEATED UNTIL THE WATER LEVEL DOES NOT DECREASE FOR A PERIOD OF 24 HOURS. ADJUST THE AIR CONDIT10NING SYSTEMS, VENTILATING SYSTEMS, FANS, ETC., TO DELIVER NOT LESS THAN THE REQUIRED AIR QUANTITY WITH QUAN11TIES IN EXCESS TO BE SUBJECT TO THE APPROVAL OF THE ENGINEER IF FOUND TO NOT HAVE OBJECTIONABLE EFFECTS SUCH AS NOISE, DRAFTS, OR MOTOR OVERLOAD. PRIOR APPROVAL BY THE ENGINEER OF TESTING AND BALANCING CONTRACTOR IS REQUIRED. REFER TO SHOP DRAWINGS AND SUBMITTAL SECTION. TEST AND BALANCE REPORTS BY NON -APPROVED CONTRACTORS WILL BE REJECTED. THIS CONTRACTOR SHALL PROVIDE A MINIMUM OF THREE (3) COPIES OF A TEST AND BALANCE REPORT TO THE ENGINEER AT TIME OF SUBSTANTIAL COMPLETION INSPECTION. THE TEST AND BALANCE REPORT SHALL BE PREPARED BY A CONTRACTOR CERTIFIED BY ASSOCIATED AIR BALANCE COUNCIL OR NATIONAL ENVIRONMENTAL BALANCING BUREAU EPORT SHALL BE TYPEWRITTEN AND CONTAIN THE FOLLOWING DATA: 1. DATE, TIME, WEATHER, MEN TEST TAKEN. 2. VOWMETRIC AIR FLOW RATES AT EACH UNIT/FAN, INCLUDING SUPPLY, RETURN, EXHAUST AND OUTSIDE AIR AS APPLICABLE. 3. STATIC PRESSURE THROUGH UNITS AND UNIT COMPONENTS. 4. MOTOR OPERATING VOLTAGE AND AMPERAGE. 5. DRIVE TYPES, SIZES AND SPEED RANGE. 6. AIR FLOW PROPERTIES BEFORE AND AFTER UNIT INCLUDING: DRY BULB, WET BULB AND DEW POINT FOR SUPPLY, RETURN, EXHAUST AND OUTSIDE AIR AS APPLICABLE. 7. AIR FLOW PROPERTIES BEFORE AND AFTER ALL HEAT EXCHANGE DEVICE (COILS, FANS, ENERGY RECOVERY DEVICES, ETC.) INCLUDING: DRY BULB, WET BULB AND DEW POINT. 7. FLUID FLOW PROPERTIES BEFORE AND AFTER ALL HEAT EXCHANGE DEVICE (COILS, ETC.) INCLUDING: ENTERING WATER TEMPERATURE, LEAVING WATER TEMPERATURE, FLOW RATE AND FLUID PRESSURE DROP THROUGH COMPONENT. 9. IDENTIFICATION OF ALL VARIABLE AIR VOLUME DEVICES WTH DESIGN AIRFLOW, MINIMUM AIRFLOW, ENTERING AIR TEMPERATURE AND LEAVING AIR TEMPERATURE. 10. PLAN IDENTIFYING ALL AIR TERMINAL DEVICES WITH DESIGN CFM AND ACTUAL CFM. MAINTENANCE MANUALS PROVIDE COMPLETE MAINTENANCE MANUALS (3 REQUIRED) ON ALL NEW EQUIPMENT. ORGANIZE OPERATING AND MAINTENANCE DATA INTO SUITABLE SETS OF MANAGEABLE SIZE. BIND PROPERLY INDEXED DATA IN INDIVIDUAL, HEAVY-DUTY, 2-INCH, 3-RING VINYL -COVERED BINDERS NTH POCKET FOLDERS FOR FOLDED SHEET INFORMATION. MARK APPROPRIATE IDENTIFICATION ON FRONT AND SPINE OF EACH BINDER. INCLUDE THE FOLLOWING TYPES OF INFORMATION. THE INFORMATION WILL BE TURNED OVER TO THE OWNER AT TIME OF SUBSTANTIAL COMPLETION: :OPERATING AND MAINTENANCE INSTRUCTIONS SPARE PARTS LIST 0 0 WRING DIAGRAMS 0 INSPECTION REPORTS & APPROVALS * SHOP DRAWINGS AND PRODUCT DATA 0 TEST AND BALANCE INFORMATION TRAINING SERVICES THOROUGHLY INSTRUCT THE OWNER'S REPRESENTATIVE IN THE OPERATION OF ALL EQUIPMENT FURNISHED AND LOCATION OF ALL VALVES AND CONTROL DEVICES. TRAIN BUILDING OWNER'S PERSONNEL DURING NORMAL WORKING HOURS ON START-UP ES, TROUBLESHOOTING PROCEDURES, SERVICING AND PREVENTATIVE MAINTENANCE SCHEDULE AND PROCEDURES. REVIEW WITH THE OWNER'S PERSONNEL, THE DATA CONTAINED IN THE OPERATING AND MAINTENANCE MANUALS. SCHEDULE TRAINING WITH OMER, PROVIDE AT LEAST 7-DAYS PRIOR NOTICE TO ARCHITECT/ENGINEER. SYSTEM IDENTIFICATION EQUIPMENT TAGS ON DESIGN DRAVANGS DO NOT NECESSARILY REFLECT BUILI)ING EQUIPMENT TAGS. DRAVANG TAGS ARE FOR INS PROJECT ONLY AND AM 70 BE USED ONLY FOR REFERENCE COORDINATE SPECIFIC EQUIPMENT TAG INDICATIONS WTH BUILDING ENGINEER AND MY BUILDING AUTOMA11ON SOFTWARE FOR CORRECT AND ACCURATE REFERENCE TAGS. PROVIDE IDENTIFICA11ON LABELS ON OR NEAR EACH PIECE OF MAJOR EQUIPMENT AND EACH OPERATIONAL DEVICE AND DISCONNECT. THE LABELS SHALL BE CONSTRUCTED OF ENGRAVED PLAS11C LAMINATE SIGN OR PLAS11C EQUIPMENT MARKER PERMANENTLY SECURED TO EQUIPMENT. THE LETTERING SHALL BE A MINIMUM OF r INCH HIGH FOR EQUIPMENT NAME AND W FOR EQUIPMENT INFORMATION. MECHANICAL CONTRACTOR SHALL MAKE AN EFFORT TO PRESERVE AND MAINTAIN READABILITY OF THE MANUFACTURER'S EQUIPMENT TAG INFORMATION AND SHALL CLEARLY INDICATE ADJACENT TO THE TAG THE KW OF THE HEATER INSTALLED IN UNIT. mr�izIe�;ga.*N-Ik�ibs�icallizt&0 PROVIDE ALL NECESSARY DUCTWORK AND PIPE SUPPORTS, HANGERS, RODS, CLAMPS AND ATTACHMENTS TO PROPERLY INSTALL AND SUPPORT DUCTWORK, PIPING AND EQUIPMENT FROM THE BUILDING STRUCTURE. PROVIDE ANY ANGLE IRON OR UNISTRUT AND SUSPENSION RODS REQUIRED TO INSTALL EQUIPMENT, PIPING AND DUCTWORK. ALL SUPPORTS EXPOSED TO OUTDOORS SHALL BE CLEANED, PRIMED AND PAINTED TO PREVENT RUSTING. FINISH COLOR AS SELECTED BY OWNER. THE USE OF BALING WIRE, NATURAL OR SYNTHETIC FABRIC STRAPS, OR PERFORATED METAL STRAPPING IS NOT ACCEPTABLE FOR SUPPORTS. WARRANTY/GUARANTEE: THE CONTRACTOR SHALL WARRANTY/GUARANTEE AND MAINTAIN THE STABILITY OF WORK AND MATERIALS AND KEEP SAME IN PERFECT REPAIR AND CONDITION OF THE PERIOD OF ONE (1) YEAR. DEFECTS OF ANY KIND DUE TO FAULTY WORK OR MATERIALS APPEARING DURING THE ABOVE MENTIONED PERIOD MUST BE IMMEDIATELY TRACTOR AT HIS OWN EXPENSE TO THE ENTIRE SATISFACT10N M TECT AND ENGINEER. SUCH RECONSTRUCTION AND REPAIRS SHALL INCLUDE ALL DAMAGE TO THE FINISH OR FURNISHING OF THE BUILDING RESULTING FROM THE ORIGINAL DEFECT OR REPAIRS THERETO. HEA11NIGZVEN11LA11NIGZAIR COND11IONING SPECIFICATIONS FURNISH AND INSTALL COMPLETE AIR CONDITIONING SYSTEMS AS INDICATED ON THE DESIGN DRAWINGS AND AS OUTLINED WITHIN THESE SPECIFICATIONS. WORK SHALL INCLUDE BUT NOT BE LIMITED TO THE FABRICATION AND/IOR INSTALLATION OF THE SCHEDULED AIR CONDITIONING UNITS, EXHAUST FANS, VARIABLE VOLUME BOXES, AIR DISTRIBUTION AND DUCTWORK. EQUIPMENT-. AIR CONDITIONING UNITS: UNITS SHALL BE SINGLE PACKAGE AIR-TO-AIR ELECTRIC AIR CONDITIONING SYSTEMS AS SCHEDULED ON THE DESIGN DRAWINGS. UNITS NTH INTEGRAL ELECTRIC RESISTANCE HEATERS SHALL HAVE A SINGLE -POINT ELECTRIC CONNECTION. TOTAL COOLING CAPACITY OF THE UNITS SHALL BE AS SCHEDULED ON DRAWNGS. UNIT CABINET SHALL BE CONSTRUCTED OF GALVANIZED STEEL, ZINC COATED AND COATED NTH BAKED ENAMEL CABINET INSULATION SHALL COMPLY WITH FLORIDA ENERGY CONSERVATION CODE REQUIREMENTS. REFRIGERATION SYSTEM - THE UNITS SHALL CONTAIN HERMETIC COMPRESSORS WITH SERVICE VALVES AND VIBRATION ISOLATION. UNITS SHALL HAVE DUAL COMPRESSORS AND DUAL REFRIGERATION CIRCUITS OR CAPACITY REDUCTION STEPS WHERE INDICATED ON EQUIPMENT SCHEDULE. FANS AND MOTORS - THE INDOOR AIR FANS SHALL BE OF THE FORWARD -CURVED CENTRIFUGAL CLASS 1 TYPE OR DIRECT DIRECT PLENUM STYLE. THE OUTDOOR AIR FANS SHALL BE OF THE PROPELLER TYPE, EACH DIRECTLY DRIVEN BY AN INHERENTLY PROTECTED MOTOR. MOTOR AND DRIVE TO PROVIDE HIGHER FAN OUTPUT WHEN JOB REQUIREMENTS EXCEED STANDARD FAN CAPACITY SHALL BE PROVIDED. SAFETY CONTROLS - COOLING SYSTEM SHALL BE PROTECTED BY. LOSS OF CHARGE PROTECTION, HIGH AND LOW PRESSURESTAT, COMPRESSOR MOTOR OVERLOADS, AND A TIMING DEVICE WHICH WILL PROHIBIT THE COMPRESSOR MOTOR FROM BEING SUBJECTED TO A STARTING CURRENT MORE THAN ONCE EVERY FIVE MINUTES. CONTROLS - PROVIDE PROGRAMMABLE, WALL MOUNTED, HEAT/COOL ON -OFF -AUTO THERMOSTAT FOR EACH UNIT. UNITS RECEIVING OUTSIDE AIR FOR THE PURPOSE OF VENTILATION SHALL BE PROVIDED WI SITION, OUTSIDE AIR INTAKE DAMPER WITH HOOD PROVIDE A ONE (1) YEAR WARRANTY ON THE COMPLETE SYSTEM AND AN ADDITIONAL FOUR (4) YEAR FACTORY WARRANTY ON ALL COMPRESSORS. LOSS OF REFRIGERANT WILL BE REPLACED AT NO COST TO OWNER FOR A PERIOD OF ONE (1) YEAR. CONDENSATE DRAINS: SCHEDULE 40 PVC ROUTED AS INDICATED ON PLANS. INSULATE WITH 1/2- ELASTOMERIC FOAM INSULATION RATED FOR PLENUM APPLICATION. INSTALL PER 'S RECOMMENDATIONS. COPPER PIPING THAT PENETRATES MASONRY WALLS SHALL BE PROPERLY SLEEVED AND SEALED WEATHERTIGHT AT EACH MASONRY PENETRATION. CONDENSATE PIPING INSULATION EXPOSED TO OUTDOORS SHALL BE INSULATED WITH 1/2- FOAMGLASS CLOSED -CELL INSULATION AND PROTECTED MTH 0.032- EMBOSSED ALUMINUM JACKET SECURED NTH BANDS (NOT SCREWS). JACKET SHALL BE INSTALLED WITH THE SEAM ON THE BOTTOM TO PREVENT WATER ACCUMULATION MEN EXPOSED TO THE OUTDOORS. REFRIGERATION PIPING: ALL WORK DESCRIBED IN THIS SEC11ON SHALL BE PERFORMED ONLY BY SKILLED REFRIGERATION MECHANICS. REFRIGERATION PIPING SHALL BE FIELD FABRICATED. WORKMANSHIP ON THESE SYSTEMS MUST BE GOOD, AND CLEANUNESS OF THE PIPING SYSTEMS IS MANDATORY. WORK THAT DOES NOT MEET THESE CRITERIA SHALL BE REMOVED AND REPLACED AT NO COST TO THE OWNER. THE ENGINEER SHALL DETERMINE METHER THE WORK MEETS THESE CRITERIA. PIPING SHALL BE ASTM B280 MUELLER STREAMLINE ACR OR READING TYPE ACR FACTORY SEALED NITROGEN CHARGED SPECIAL REFRIGERATION DUTY COPPER TUBING. FITTINGS SHALL BE MUELLER OR NIBCO WROUGHT COPPER LONG RADIUS REFRIGERATION TYPE. REFRIGERANT PIPING BELOW GRADE SHALL BE ROUTED IN MINIMUM 4 IN. DIAMETER PVC PIPE SLEEVES TO EACH CONDENSING UNIT. ALL UNDERGROUND REFRIGERANT PIPING SHALL BE CONTINUOUS SOFT -DRAWN TUBING WITH NO UNDERGROUND JOINTS ALLOWED. REFRIGERANT PIPE SIZES SHALL BE SIZED PER A/C EQUIPMENT MANUFACTURER-S ON LENGTH OF RUN BETWEEN CONDENSING UNITS AND AHU'S. SOLDER SHALL BE 4% SILVER/96% TIN WITH MELTING POINT OF 430-F WITH TENSILE STRENGTH OF 14,000 PSI AND SHEAR STRENGTH OF 10,600 PSI, BRIGHT SILVER NON -OXIDIZING COLOR. 95-5 SOLDER WILL NOT BE PERMITTED. DO NOT BRAZE. J.W. HARRIS STAY-BRITE AND ENGELHARD BRAZE -IT 430 ARE ACCEPTABLE. FILL PIPING WITH OIL PUMPED DRY NITROGEN DURING ALL SOLDERING OPERATIONS. BUILD UP 20 PSIG IN SYSTEM NTH R-410A AND THEN INCREASE PRESSURE TO 150 PSIG IN SYSTEM WITH R-410A AND THEN INCREASE PRESSURE TO 150 PSIG IN SUCTION PIPING WITH 350 PSIG IN HIGH SIDE PIPING WITH DRY NITROGEN. TAP ALL FITTINGS WITH RUBBER MALLET. LEAK TEST WITH HALIDE TORCH. REPAIR ANY LEAKS DISCOVERED BY COMPLETELY REMAKING THE LEAKING JOINTS. REPEAT PROCEDURE UNTIL SYSTEM IS PROVEN TIGHT FOR A 24 HOUR PERIOD. U EVACUATE SYSTEM TO 0.1' HG ABSOLUTE, MEASURING SAME WITH ZIMMERLI VACUUM GAUGE OR MANOMETER. BREAK VACUUM BY INJECTING R-410A INTO SYSTEM AT FARTHEST POINT IN PIPING FROM COMPRESSOR. RE -EVACUATE TO 0.1" HG ABSOLUTE. SYSTEM MUST HOLD THIS VACUUM FOR 15 MINUTES. REPAIR LEAKS AS REQUIRED UNTIL IT DOES. CHARGE SYSTEM WITH PROPER QUANTITY OF REFRIGERANT. ING (INDOORS AND OUTDOORS), FITTINGS, VALVES, ETC., VES, HANGERS, ETC., WITH 3/4- ELASTOMERIC INSULATION (ARMACELL MODEL# AP-ARMAFLEX). INSTALLATION SHALL BE CONDENSATION -FREE, AND INSTALLED ACCORDING TO MANUFACTURER'S RECOMMENDATIONS. PROTECT ALL INSULATION EXPOSED TO OUTDOORS WITH 0.032" EMBOSSED ALUMINUM JACKET SECURED WITH BANDS (NOT SCREWS). JACKET SHALL BE INSTALLED WITH THE SEAM ON THE BOTTOM TO PREVENT WATER ACCUMULATION WHEN EXPOSED TO THE OUTDOORS. PIPE HANGERS, WHERE NEEDED, SHALL BE ANVIL/GRINNELL #260 CLEMS TYPE, 5 FEET ON CENTER, SECURELY ATTACHED TO BUILDING CONSTRUCTION. COPPER PIPING THAT PENETRATES MASONRY WALLS SHALL BE PROPERLY SLEEVED AND SEALED WEATHERTIGHT AT EACH MASONRY PENETRATION. NES SECURELY ALONG PAD/FLOOR/EQUIPMENT/STRUCTURE TO PREVENT MOVEMENT. SUPPORT IN A MANNER THAT LINES THAT DO NOT HANG FROM EVAPORATOR CONNECTIONS OR BLOCK ACCESS TO FILTERS, CONTROLS, ETC. TRAP OIL IN SUCTION LINE AT EVAPORATOR COIL NO OTHER COIL TRAPS PERMITTED. PROVIDE SUCTION RISERS, CHECK VALVES, SOLENOID VALVES, OR OTHER DEVICES REQUIRED IN PIPING SYSTEM BY MANUFACTURERS INSTALLATION INSTRUCTIONS. FURNISH ALL LABOR AND MATERIALS TO REPLACE REFRIGERANT LOST DURING THE ONE YEAR WARRANTY PERIOD. CONTROLS FACTORY MOUNTED CONTROL SHALL BE PROVIDED TO ACCOMPLISH THE SEQUENCE OF OPERATION. ALL INTERIOR CONTROLS SHALL BE FACTORY FURNISHED AND INSTALLED. HVAC LEGEND 11 SUPPLY AIR DIFFUSER 0 RETURN AIR GRILLE 11 EXHAUST AIR GRILLE rl_ = .4 rr ��;Al rr = __41 if ),/ I EXISTING SUPPLY AIR DIFFUSER 11 ' 11 EXISTING RETURN AIR GRILLE 11 11 EXISTING EXHAUST AIR GRILLE a L�__ A L�m 94, DEMOLISHED SUPPLY AIR DIFFUSER 0, GRILLE to, DEMOLISHED EXHAUST AIR GRILLE TAG DIFFUSER DESIGNATION *_____4 NEW DUCTWORK (SINGLE LINE) ?______z CFM .*�� NEW FLEX DUCT 4=1- SPIN -IN COLLAR WITH DUCTWORK TO BE REMOVED VOLUME DAMPER VDF_ VOLUME DAMPER FD_�_, EXISTING DUCTWORK & POINT OF CONNECTION 2-- WITH EXITING FIRE DAMPER (1) THERMOSTAT T F/SD _4, X 2-- _, E isTING DUCTWORK NTH @ SMOKE DETECTOR :Ak�s WITH NEW FIRE DAMPER . / I EXISTING FIRE/SMOKE DAMPER ' EXISTING DUCTWORK I TAG ft NEW DUCTWORK WITH WITH NEW FIRE/SMOKE DAMPER I CFM I EQUIPMENT TAG ll�� . NEW FIRE DAMPER F/ NEW DUCTWORK WITH NEW FIRE/SMOKE DAMPER AIR DISTRIBUTION EQUIPMENT: GRILLES AND RETURN AIR REGISTERS AS SCHEDULED ON THE DESIGN DRAWINGS. TITUS, PRICE AND METALAIRE MAY BE SUBSTITUTED AS AN EQUAL. GRILLES, REGISTERS, AND CEILING DIFFUSERS SHALL BE FURNISHED AS SCHEDULED ON THE DESIGN DRAWINGS AND SHALL BE ALL METAL CONSTRUCTION. AIR DISTRIBUTION SHALL NOT EXCEED NC-30 NOISE CRITERIA AS DEFINED IN THE LATEST ASHRAE GUIDE. DUCTWORK: CONSTRUCTED TO CONFORM TO LATEST EDITION OF SMACNA STANDARDS BASED ON THE FOLLOWNG CRITERIA. 1. SUPPLY AIR: 2 IN. W.G. POSITIVE PRESSURE (CLASS C) 2. RETURN AIR: 1 IN. W.G. NEGATIVE PRESSURE (CLASS C) 3. OUTSIDE AIR: 2 IN. W.G. PosiTivE/NEGATIVE PRESSURE (CLASS C) 4. EXHAUST AIR: 1 IN. W.G. POSITIVE/NEGATIVE PRESSURE (CLASS C) K: 0 GALVANIZED STEEL OF GAUGES CONFORMING TO LATEST EDITION OF SMACNA RITERIA ABOVE. THE GALVANIZED DUCT COATING SHALL BE G-90. (APPLICABLE FOR SUPPLY, RETURN AND EXHAUST) FLEXIBLE DUCTWORK SHALL BE ACOUS11CAL LOW PRESSURE TYPE WITH INTERIOR LINER, METAL HELIX, 1- FIBERGLASS INSULATION, AND COPOLYMER SEAMLESS OUTSIDE SLEEVE. THE ENTIRE FLEXIBLE DUCT ASSEMBLY SHALL BE LISTED IN ACCORDANCE WITH UL-181 CLASS 1 AIR DUCT MATERIAL THE MAXIMUM LENGTH OF ANY FLEX DUCT SHALL BE 8'-O". THIS APPLIES TO NEW FLEXIBLE DUCTWORK ONLY. EXISTING FLEXIBLE DUCTWORK EXCEEDING EIGHT FEET IN LENGTH MAY REMAIN (AT BUILDING OWNER'S DISCRETION) PROVIDED IT IS PROPERLY HUNG AND SUPPORTED PER ASHRAE ALLOWS FOR UNRESTRICTED AIRFLOW. EXCESSIVE NOISE OR INSUFFICIENT AIRFLOW SHALL BE CAUSE FOR REPLACEMENT OF FLEXIBLE DUCTWORK TO COMPLY WITH THE ABOVE MENTIONED LENGTH RESTRICTIONS. REPLACE EXISTING FLEX DUCT WHICH EXCEEDS 8'-Om IN LENGTH WITH ROUND SHEET METAL DUCT. "DAISY CHAIN" OF MORE THAN ONE 8'-Om SECTION OF FLEX WITH RIGID DUCT IN BETWEEN IS NOT ACCEPTABLE. FLEXIBLE DUCTWORK SHALL BEAR MANUFACTURER APPLIED LABELING INDICATING DUCT DIAMETER ON OUTER FACE (8' MAXIMUM SPACING). ALL DIMENSIONS ARE INSIDE NET FREE AREA. ADJUSTABLE SPUTTERS AND DAMPERS SHALL BE INSTALLED IN EVERY SPLIT AND BRANCH DUCT AND SHALL BE PROVIDED WITH LOCKING QUADRANTS ON EXPOSED OR IN ACCESSIBLE AREAS OF THE DUCT FOR EASE OF OPERATION. ELBOWS OR CHANGES IN DUCT DIRECTION GREATER THAN 45 DEGREES SHALL BE FITTED WITH AIR TURNS CONSISTING OF CURVED AIRFOIL BLADES OR VANES MICH WILL PERMIT THE AIR TO MAKE ABRUPT TURNS WITHOUT APPRECIABLE TURBULENCE. FIRE SAFETY CONTROLS: AS A MINIMUM REQUIREMENT, INSTALL DUCT SMOKE DETECTOR FURNISHED AND WRED BY DIVISION 26 IN SUPPLY AIR DUCTS OF UNITS EXCEEDING 2,000 CFM AND IN THE RETURN AIR DUCTS OF UNITS EXCEEDING 15,000 CFM. DETECTOR TO SHUT UNIT OFF MEN ACTIVATED. VIBRATION ISOLATION: ALL BLOWER UNITS AND VIBRATING TYPE EQUIPMENT SHALL BE PROPERLY FITTED WITH MASON INDUSTRIES VIBRATION ISOLATION EQUIPMENT SIZED IN ACCORDANCE WITH EQUIPMENT WEIGHT AND DUTY. VI ECTORS AT ALL SUPPLY AND TO AIR HANDLING EQUIPMENT CONSISTING OF HEAVY CANVAS OR NEOPRENE FABRIC WITH AIR -TIGHT SEAMS AND CONNECTIONS TO THE EQUIPMENT. AIR FILTERS: FILTERS SHALL BE 20% EFFICIENT lm PLEATED MEDIA, DISPOSABLE TYPE IN A RIGID FRAME WITH A SUPPORTING MAZE ACROSS BOTH ENTERING AND LEAVING SURFACES. SUPPLY ONE COMPLETE SET OF EXTRA FILTERS AFTER OWNER'S FINAL ACCEPTANCE. FARR 20/20 OR EQUAL INSULATION: RED BY CERTAINTEED, OWENS-CORNING, JOHNS MANVILLE, PITTSBURGH CORNING, ARMSTRONG, OR APPROVED EQUAL INSULATION SUNDRIES AND ADHESIVES SHALL BE AS MANUFACTURED BY BENJAMIN FOSTER, CHILDERS, \AMASCO, INSULA11ON SHALL BE SUITABLE FOR INSTALLATION IN A RETURN AIR PLENUM. INSULATE ALL SHEETMETAL DUCTWORK EXCEPT EXHAUST DUCTWORK EXTERNALLY WITH MANVILLE MICROUTE FSK INSULATION (TYPE 75 OR 100) OR APPROVED EQUAL INSULA11ON TO HAVE FSK FACING AND UL FIRE HAZARD CLASSIFICATION OF- FLAME SPREAD 25, SMOKE DEVELOPED 50, FUEL CONTRIBUTED 50. INSTALL INSULATION PER SMACNA, FLORIDA MODEL ENERGY EFFICIENCY CODE AND MANUFACTURER'S RECOMMENDATIONS. ALL INSULATION JOINTS SHALL BE SEALED NTH GLASS FABRIC AND MASTIC. MINIMUM INSULATION VALUES (THICKNESSES) ARE AS FOLLOWS: 0 R IN UNCONDITIONED SPACE: R-4.2 MIN. (1.5-) 0 OUTSIDE AIR: R-6.0 MIN. (2") ABOVE REQUIREMENTS ARE BASED ON THE 2020 FLORIDA BUILDING CODE, 7TH EDITION, ENERGY CONSERVATION. CONTRACTOR SHALL MATCH EXISTING INSULATION CONDITIONS WHERE THEY EXCEED THE ABOVE TABLE. PIPING INSULATION EXPOSED TO OUTDOORS SHALL BE INSULATED NTH CLOSED -CELL FOAMGLAS INSULATION WITH AN INSULATING VALUE IN COMPLIANCE WITH FLORIDA ENERGY CODE TABLE C403.2.10 BASED ON FLUID TEMPERATURES. PIPING SHALL BE PROTECTED WITH 0.032' EMBOSSED ALUMINUM JACKET SECURED WITH BANDS (NOT SCREWS). JACKET SHALL BE INSTALLED WITH THE SEAM ON THE BOTTOM TO PREVENT WATER ACCUMULATION WHEN EXPOSED TO THE OUTDOORS. SPONSIBLE FOR FURNISHING AND INSTALLING ADEQUATE AND PROPER INSULATION AND MOISTURE -SEAL IN A MANNER THAT WILL PERMANENTLY PREVENT THE ACCUMULATION OF MY OBJECTIONABLE MOISTURE ON THE EXTERIOR OF AIR CONDITIONING UNITS, REFRIGERANT PIPING, CONDENSATE DRAIN PIPING, AIR DUCTS YSTEM. CONTRACTOR SHALL CORRECT THE CAUSE OF MY CONDENSATION AND FULLY REPAIR, WITHOUT COST TO THE OWNER, MY DAMAGES TO BUILDING SURFACES, FURNISHINGS OR EQUIPMENT CAUSED BY CONDENSATION FROM THIS SYSTEM, FOR THE FULL PERIOD OF THE GUARANTEE. MEP CONSULTING ENGINEERS SINCE 1977 FL REG NO. 3089 2016 ALDEN RD. ORLANDO, FL 32803 (407) 246-1688 WWW.PEIFLA.COM PEI PROJECT A 22121 1W L A A I -_ - - � CAMPBELL + VAN DUSEN IA RCH ITE CT U RE IN-ERIOR DE.31,aN www.CVDstudio.com CAMPBELL + VAN DUSEN Design Studio, LLC 255 South Orange Avenue Suite # 1 240 Orlando, Florida 32801 Phone: 407.930.6016 FL. Lic. No. AA26003339 ARCHITECT OF RECORD FRANK W. CAMPBELL AIA FL LIC NO. AROO 1 6053 COPY OF THIS PLAN IS NOT VALID UNLESS SIGNED, SEALED AND DATED BY THE ARCHITECT OF RECORD ,\,\ . � oft JA // � �� _-k'� . . . ......... � � ///,- "", , �� ':� A��;" i� I c R ***"-%. <ON .." Z'� . 0� � ..' Z�- * / NO lk -::� = : . .1 .- .0 : - - 1 90018 U) . - - ;a '. * I = =: 0 I .. S7A : *:z .- % �' ..6 .% 7"e OF '� �_ ' I .� . A�, J.. .,., 0. -, Z ,4 _� 4p, \ of? I N -`4'.k_, !:�,� " 0,.,. D ­0 "'., �­' ;e Z, ...... ' '_l ////- % "', Vt% ��' G N � Fit �\\'� * ... ", ///////IIIIl0\ q'.z.s-�,2 I, --- FL Reg. No. 90018 Taylor J. Lewis, PE, COPY OF THIS PLAN IS NOT VALID UNLESS SIGNED, SEALED AND DATED BY THE ENGINEER OF RECORD -_ - _j U_ vi j _j = :z Q� 0 >_ = �-_ 2= = CL LLJ cle �-- r�4 U 1 < 6 L.') LU LU (/) I > I 0 = I _= ca I- I--- + LO _j _j U----*w 0 W < LLJ ___) LU I >- () 0 > Il = cl- - NO llq ck� CL C) Lu 3: PL-U4 -_0 LO or-?. ccyo) < CONSTRUCTION DOCUMENTS 03.24.2023 PRINCIPAL IN CHARGE F. CAMPBELL .................................................................... PROJECT MANAGER M. TORRES ......................................................... I .......... - ADVENT HEALTH WELL 65+ ZEPHYRHILLS 22-0328-01 MECHANICAL SPECIFICATIONS MO* I 10 9 8 6 5 3 2 1 A- A A. 4 4 - A BIO A z -A 4, f A-- < 4 4­ It 1� — — — — — — — — — — — — — — — — — — A. I Z ., ' ' I - . 4-;' - — — — — — — — — A , - . '�A' , A �4 R -1 R -1 RG- IF-711 R I R cno CD C) X L:__�j 8X W CD 00 1 OA 4 00 �? —11 �2 ITE 11 RG-1 RG-1 1311 VV rZ L L N MS %'-*) %S E. 12X12 WF_LtNF=5b bU 8 4 CD-2 WELLNESS SUITE 6 7 m__Z I 2 11 5 1 113 175 W LN S S UITE L i0xio 2- 200 200 00 PONL Mi 200 12X12 ONSULT ROO�_ 10 00 1 C 0-- OT TT�-2 — T_ T 116 CD-2 RG- 200 80 74:r CORRIDOR C::I� IWO 14X1 4 12X1 2 RG-1 i 80 PA I T 80 80 CD-1 CD-1 COORDINATOR T T _j 0 81 80\---g 70 = I]- CD-1 75 CORRIDOR 75 1 El 75 A 100 100 i0xi R -1 ESS SUITAL-11 CD 3 C14 EF-4 4 FM I-c" - F- EW) 24X14 ?25 rr_�� j 10X10 CORRIDOR X 1OX10 RG-1 U:� W_oF CD A RTU-2 L 0 law! 0 o 60 2 , b� 14XI 4 RG-1 TU-1 I 4X16 X p .4- 00 MED ROOM X 00 1 118 X 6 L -00 CORRIDOR CD-1 CD-1 NA RG-1 12X1 2 P, i0xio T WELLNESS SUITE 80 80 100 125 VN 2 00 X X FI-08-1 80 I f__ STOF;b C3 P OVI R WORK , CD-1 0 RG-1 1 R OM 8X8 100 1 7- 5 1 80 r- 100 HUDDLE 132 11 80 ----- - 0- CD-1 0 0 75 —Tr- - RG-1 CD-2 RG-1 (13D 200 ?25 RG-1 j 10X10 F L 80 0 LL 0 Unj 2 r4 L - . - — - _.. d — - - - - - — - — L6� rL �r 16X1 4 0 Y 1 1 80 60 127 0 I CD-1 W 80 CD-1 CD-1 100 80 75 100 VN 100 Lnsi C) I 1 r<2) 11 80 80 CD-1 cilli -La L TOILET 100 1 ELL 4ESS SUITE EF 2 EF-1 RG-1 4 4 X 175 --- 75 CFM 0 00 8X8 (NEW) (NEW) 80 100 107 RG-1 60 Comm I zoom Er-3 3 J CD-3 3 12 0 r-7 0 Rg 75 C3FMD (NEW) DSS 1 A UTOGLAVE 150 2�zz �2 7 225 X 1 TON j 10X10 — — — — — — — — - (NEW) 60 UnjCORRIDOR I CD-1 CONSULT/BROKER ----1 75 F 102 F ct CD-1 EF-6 RG-1 CD-1 C> 100 3 100 R -1 00 75 CFM 60 1 RTU-5 (NEW) CD-3 TOILET 80 --o-1 25 F 3 24X16 3 EF-7 22X16 16X1 4 16XT4- IL 2 16 75 CFM v_ -N EF-5 (NEW) RTU-3 FF F G-1 BREAK ROOM 3 TOILET I RTU-3 14X14.__ff STORAGE1 80 CD-1 . ..... 200 C) >< I CD CD-1 CD-1 X C14 CD-1 CD-1 kn 60 1 150 0 200 200 00 80 M CD-3 LOBBY 2 60 5 100 >c 80 T [LET C�o 101 10 100 14XI 2 .4-41- Fl 0 80 80 COMMUNITY 25 12X1 2 18X1 4 12X12U fn 4 1 1 I 11 1 1 100 1)0 80 00 o RG-1 RG-1 CD-1 CD-1 100 - 200 200 200 C RG-1 C14 C14 16X1 4 CD-1 150 150 _41 — — — — — — — — — — — — — — — — — % A 4 A _'A - I A _' ­- " - . . W , , - - , *_%, - , ;A A A Al. lk A' 4 `�.,d z A A A ­ 'A 4 4 '4 .4 A, A - A- z 4;A 4 r , 4� #d A .4 A' ' - : -- # i . A 4 '.A " . 'd- A -A* d A 4 .4. 4., ..4 A A _j, _ `4� . : , " 4 4�­ A 4 '? �-, . A 4 A A A :& -. I I 4. 4'. :4 4' -A A " -, 4­4 .. __ 4 "i : . -1, A - A ;. d' -,r , :4 'd .1 . 'A . '% - -AV 4- 4 -4 4 4 " 4. L Al -LA-. ; — -7- .% t�— _1�4 7T W7- =4' A A Ik "'A A 4 4 '1. _ , _ - % . -A,. I - I . . — �:, 1: - ­� A 4 A' e A - 4' 4, .4 A (d 4' 4 A, A -A a 41 ,4 . - - ;, , A - . - , . '-A A' I . 1, 4 A A .:d,t 4% c 'A , A, . 4 A-4 A -A . tl -A A — 'd- — . . ­ A A 4 -­ - - - —1 NORTH SCALE: 1/4" = V-10" AD B ,c) D 3E 3F ,G) I'll, I NOTES TO PLAN REVIEWER I THIS PROJECT HAS BEEN DESIGNED MECHANICALLY TO COMPLY WITH THE 2020 FLORIDA BUILDING CODE (SEVENTH EDITION) - MECHANICAL AS WELL AS THE 2020 FLORIDA BUILDING CODE (SEVENTH EDITION) - EXISTING BUILDING. THE FOLLOWING SECTIONS ARE INDICATED FOR REFERENCE. ;m1mkoal . 1, . i Gli SECTION 408 MECHANICAL 408.1 GENERAL. EXISTING MECHANICAL SYSTEMS UNDERGOING REPAIR SHALL NOT MAKE THE BUILDING LESS CONFORMING THAN IT WAS BEFORE THE REPAIR WAS UNDERTAKEN. SECTION 301 GENERAL 301.14 REPAIR. DEFECTIVE MATERIAL OR PARTS SHALL BE REPLACED OR REPAIRED IN SUCH A MANNER SO AS TO PRESERVE THE ORIGINAL APPROVAL OR LISTING. IT IS THE INTENT OF PENINSULA ENGINEERING, INC. TO BRING NEW AND/OR RENOVATED MECHANICAL SYSTEMS TO COMPLIANCE WITH CURRENT CODE REQUIREMENTS. EXISTING MECHANICAL SYSTEMS NOT BEING RENOVATED, REPAIRED, OR ALTERED SHALL BE LEFT IN AS -IS CONDITION WITH THE UNDERSTANDING THAT SUCH CONDITIONS MET CODE REQUIREMENTS AT THE TIME OF INSTALLATION AND, THEREFORE, DO NOT REQUIRE ALTERATIONS FOR THE PURPOSE OF THE SCOPE OF THIS PROJECT. KEY NOTES NEW SUPPLY AND RETURN DUCTWORK UP TO NEW ROOFTOP PACKAGE UNIT ABOVE. EXHAUST DUCT UP THROUGH ROOF TO GOOSENECK. Q CEILING MOUNTED CABINET EXHAUST FAN. PROVIDE WITH INTEGRAL mo-nON SENSOR. CEILING MOUNTED CABINET EXHAUST FAN. FAN SHALL RUN CONTINUOUSLY, INTERLOCK WITH ASSOCIATED AIR HANDLING UNIT. ALL THERMOSTATS SHOWN ARE TEMPERATURE SENSORS ONLY. SENSORS SHALL REPORT BACK TO MAIN TEMPERATURE CONTROL PANEL LOCATED IN MANAGER'S OFFICE. MAIN TEMPERATURE CONTROL PANEL PANEL SHALL BE CAPABLE OF ILLUSTRATING THE TEMPERATURE AT EACH SENSOR AS WELL AS SETTING THE TEMPERATURE AT EACH SENSOR. DUCTLESS SPLIT AC UNIT HIGH ON WALL. PROVIDE CONDENSING UNIT ON ROOF AND ROUTE CONDENSATE TO NEAREST CONDENSATE REMOVAL LOCAT10N (STORM WATER SYSTEM). CAMPBELL + VAN D 1A R C H I T E C T U R E IrA_ERI0F DIE-3115�N vvww.CVDstudio.com CAMPBELL + VAN DUSEN Design Studio, LLC. 255 South Orange Avenue Suite # 1240 Orlando, Florida 32801 Phone: 407.930.6016 FL. Lic. No. AA26003339 ARCHITECT OF RECORD FRANK W. CAMPBELL AIA FL LIC NO. AROO 16053 COPY OF THIS PLAN IS NOT VAUD UNLESS SIGNED, SEALED AND DATED BY THE ARCHITECT OF RECORD m 0 ................... < <,, No. 90018 TE OF 41 -zz- R I'D # Tay1or J. Lewis, PE, FL Reg. No. 90018 COPY OF THIS PLAN IS NOT VALID UNLESS SIGNED, SEALED AND DATED BY THE ENGINEER OF RECORD _j Li- 0 < ci LU LU > _j 0 F— + Lr) (-) ,0 < LU ) LU > I (D 0 -0 It NO LO tie LU co cy) a_ P._4 Ill CO CONSTRUCTION DOCUMENTS 03.24.2023 DESCRIPTION PRINCIPAL IN CHARGE F. CAMPBELL .. ................................................................. PROJECT MANAGER M. TORRES .................................................................... ADVENT HEALTH WELL 65+ ZEPHYRHILLS 22-0328-01 MEP CONSULTING MECHANICAL ENGINEERS SINCE 1977 RENOVATION PLANS FL REG NO. 3089 2016 ALDEN RD. ORLANDO, FL 32803 (407) 246-1688 WWW.PEIFLA.COM m I I PEI PROJECT it 22121 4 4< 4 A F _1 F_ EXIS11NG PARAPET WALL 0 '0 cii4 RTU-4 1 RTU-2 CD 4 TONS 4 TONS (NEW) (NEW) ZEXISTING ROOF C) CU-1 3 1 TON (NEW) CD 0 C5 RTU-3 5 TONS (NEW) a RTU-5 al/ 5 TONS (NEW) EXISTING PARAPET WALL 4 4 4 .4 -4- < 4 < < '4 4 < 4 4 < 4 4 .. <4 4 < < Id * ' ' < ' . . . .. <4 ' 4' 4 < < 4' .4. 4 A 4 (> 1 /M2.1 NORTH SCALE: 1/4" = 1'-0" GENERAL RENOVA110N NOTES 1. CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS PRIOR TO SUBMIT71NG BID. 2. CONTRACTOR SHALL MAINTAIN CODE REQUIRED 10'-0' CLEARANCE BETWEEN THE EXHAUST DISCHARGE AND RTU INTAKE. RENOVA110N PLAN NOTES PROVIDE NEW ROOFTOP PACKAGE UNIT ON ROOFTOP CURB. REFER TO ROOFTOP UNIT AND CURB DETAIL. ROUTE r PVC CONDENSATE TO NEAREST ROOF DRAIN. CONDENSATE MUST BE ROUTED TO STORM WATER SYSTEM. �D PROVIDE GOOSENECK AT ROOFTOP EXHAUST DISCHARGE. PROVIDE CONDENSING UNIT FOR DUCTLESS SPLIT CONDENSER UNIT ON PRE -MANUFACTURER NOA RATED STAND. FASTEN TO STRUCTURE PER STAND MANUFACTURER'S REQUIREMENTS AND ASSOCIATED DETAILS. ADDITIONAL RTU CURB FOR FUTURE.- CAPPE6 F-W LATER CAMPBELL + VAN DUSEN IARCH ITECTU RE Itj_ERI4DF DE,31GN www.CVDstudio.com CAMPBELL + VAN DUSEN Design Studio, LLC. 255 South Orange Avenue Suite # 1240 Orlando, Florida 32801 Phone: 407.930.6016 FL. Lic. No. AA26003339 ARCHITECT OF RECORD FRANK W. CAMPBELL AIA FL LIC NO. AR001 6053 COPY OF THIS PLAN IS NOT VALID UNLESS SIGNED, SEALED AND DATED BY THE ARCHITECT OF RECORD .............. . W084 I- N s 18 No. 900 s-T TE OF 0 R ... . ........... . 10 N A%- Toylor J. Lewis, PE, FL Reg. No. 90018 COPY OF THIS PLAN IS NOT VALID UNLESS SIGNED, SEALED AND DATED BY THE ENGINEER OF RECORD _j U_ V� _17 0 _T_ CL U < V) LU LIJ > __j 0 co + Lr) _j _j U -'0 < LLj LU > 0 r-) Lu o Lr) cx < 3;-. or-01 CL rL_U4 ('Yf)) CONSTRUCTION DOCUMENTS 03.24.2023 DESCRIPTION PRINCIPAL IN CHARGE F. CAMPBELL .... I ............................................................... PROJECT MANAGER M. TORRES .................. I ................................................. ADVENT HEALTH WELL 65+ ZEPHYRHILLS 22-0328-01 MEP CONSULTING MECHANICAL 04ONMS SINCE 1977 RENOVATION PLAN FL REG NO. 3089 ROOF 2016 ALDEN RD. ORLANDO, FL 32803 (407) 246-1688 WWW.PBFLA.COM M2*1 PEI PROJECT it 22121 FILL VOID WITH BATT INSULATION. PROVIDE 2 LAYERS 5/8" GYP. BOARD AS VERTICAL SOUND WALL I I BETWEEN ROOF DECK AND RTU. COMPRESSOR 2X6 P.T. WOOD CURB FRAMING ALL SECTION Su E m CT' 10 N J" AROUND BASE OF CURB BOLTED THROUGH CURB r W ROOF DECK AND STRUCTURE BELOW 14"MIN. .0 DO NOT REMOVE ROOF DECK IN ANY AREAS OTHER THAN WHERE DUCTS PENETRATE ROOF. ROOF DECK MUST N'_ REMAIN UNDER COMPRESSOR SECTION. SUPPLY DUCT. SIZE �) _j AS SHOWN ON PLANS INSTALL ALL TRUNK DUCTS TIGHT TO BASE OF BAR JOISTS WELL CLEAR OF ALL LIGHTS PLUMBING AND DOFTOP UNITAS SPECIFIED OUTSIDE AIR HOOD WITH DAMPER ROOF CURB WITH P.T. WOOD NAILER WELDED 18 Ga. GALVANIZED SHELL 1 1/2"THK. 3 LB. RIGID INSULATION REFER TO TYPICAL CURB FLASHING DETAIL FOR ADDITIONAL REQUIREMENTS INSULATION AND METAL DECKING AS SPECIFIED BY ARCH. ROOF SURFACE AS SPECIFIED BY ARCH. BAR JOISTS ---TRANSITION RETURN DUCT. SIZE AS SHOWN ON PLANS CEILING SPECIFIED Ile BY ARCH. . NOTE: ELEC. CONFLICTS. SUPPORT ALL DUCTS FROM BAR JOISTS OR STRUCTURAL BEAMS ABOVE. REFER TO CURBS TO BE CONSTRUCTED TO MATCH SLOPE OF ROOF AND PROVIDE LEVEL TOP SURFACE. MINIMUM HEIGHT (MEASURED SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS. FROM SHORTEST DIMENSION) SHALL BE 14' ABOVE ROOF INSULATION. CURBS TO BE INSTALLED I.A.W. MANUFACTURERS INSTRUCTIONS. CURB SIZES TO BE COORDINATED BY CURB MANUFACTURER, GENERAL CONTRACTOR AND MECHANICAL PROVIDE DUCT MOUNTED SMOKE DETECTOR IN THE CONTRACTOR. CURB LOCATIONS ARE TO BE AS SHOWN ON PLANS. COORDINATE ROOF OPENINGS WITH DUCTWORK AND SUPPLY AIR DUCTWORK OF ALL UNITS IN EXCESS OF ROOFTOP UNIT ORIENTATION. MECHANICAL CONTRACTOR TO PROVIDE ROOFTOP UNIT, ROOF CURB, AND ALL DUCTING. 2000 CFM. ROOFING CONTRACTOR TO INSTALL FLASHING AND COUNTERFLASHING FOR ROOFING. ROOFTOP UNIT AND CURB DETAIL SCALE: NTS ROOF MOUNTED CONDENSING UNIT -EXISTING STEEL BEAM SUPPORT (TYPICAL) "EXISTING WELDS (TYPICAL) #10 SELF -TAPPING SCREW 2 PER CORNER (TOTAL OF 8) 2"x2mxl 6 GAUGE ANGLE IRON MIN. 3/8p BOLT, NUT AND WASHERS 2 PER CORNER (TOTAL OF 8) EXISTING PIPE COLUMN SUPPORT /-EXISTING ROOF NOTE: IT IS THE INTENT OF THIS DETAIL THAT THE CONTRACTOR PROPERLY INSTALL THE CONDENSER TO COMPLY WITH 140 MPH WIND LOADING PER 2017 FLORIDA BUILDING AND MECHANICAL CODES. ROOF MOUNTED CONDENSING UNIT DETAIL WIDTH OF MECHANICALUNIT- MINIMUM CLEARANCE ABOVE ROOF SURFACES < 24" 24" 14" < 36" 36" 18" < 48"48" 24" < 60"> 30" 60" 48" PROVIDE MOUNTING BRACKET AND BLOCKING AS REQUIRED FOR SUPPORT OF UNIT AIR FLOW I LCIVULIL I FIELD VERIFY CONTINUATION OF CONDENSATE PIPING RETURN DUCTWORK 1/2"CONDENSATE LINE WITH INSULATION DOWN IN WALL AND THRU FLOOR CONDENSATE LINE THRU WALL PROVIDE P-TRAP FOR CONDENSATE REMOVAL. REFER TO DETAIL. MIN[ -CONDENSATE PUMP IANT OR APPROVED EQUAL FILL WITH FOAM AND URETHANE AFTER PIPE INSTALLATION PIPING PENTHOUSE DETAIL DUCTLESS SPLIT SYSTEM AHU DETAIL bL;ALt: NlZ5 Lt�YVUL I ZjL;ALt: NIb SEE BEAM CLAMP DETAIL SEE BEAM CLAMP DETAIL SEE BEAM CLAMP DETAIL SEE BEAM CLAMP DETAIL SPIN -IN COLLAR DUCT 1-1/2"MIN. SEAL ALL JOINTS. #8 WIRE OR 1-1/2" STRAP HANGER MIN. STRAP FLEX DUCT HANGER SPIN -IN COLLAR SEAL ALL JOINTS. 2"x7x4" 13Y 22GA. ---------------- DUCT--,, -------- ANGLE AT BOTTOM CORNERS MINIMUM OF THREE FASTENERS, NO. 10, 3/4" SCREWS WITH TWO INSTALLED CHANNEL MAY BE USED IN LIEU ON SIDES AND ONE ON BOTTOM FLEX DUCT RIGID RECTANGULAR DUCT OF SHEETMETAL ANGLES FASTENING STRAP NO FASTENERS PERMITTED IN DUCT FIBROUS RECTANGULAR DUCT FASTENING STRAP SEE BEAM CLAMP DETAIL SEE BEAM CLAMP DETAIL SE E 2" MIN. SUPPORT STRAP 2" MI 11 1-1/2" MIN. SUPPORT OT To FLEXIBLE DUCT SHALL NOT TO 18"MA 18"MAX. FROM DEVICE T STRAP 18"MAX. FROM AX EXCEED 1/2" PER FOOT MAX M AND 5'-0" ON CENTER AND 51 DEVICE. DE MAXIMUM ALLOWABLE LENGTH OF FLEX DUCT 6 1 9 "11�61�0" " FLEX DUCT DUCT MAINTAIN RADIUS OF BEND TO NOT LESS THAN ONE DUCT DIAMETER FLEX DUCT DUCTWORK SUPPORT DETAILS SCALE: NTS WHERE W/H 4 R/H 1 UH 1.5 RETANGULAR DUCT WITH 4-900 SMOOTH RADIUS ELLS TO AVOID OBSTRUCTION VELOCITY FPM 800 1200 1600 2000 2400 (M/S) (4) (6) (8) (10) (12) C 0.18. 0.22 1 0.24 0.25 0.26 W"l< L B WHERE W/H 1.0 TO 3.0 B = 12" TO 24" RETANGULAR DUCT WITH 4-900 MITERED ELL TO AVOID OBSTRUCTION COEFFICIENT C UH RATIO 0.5 1.0 1.5 2 SINGLE BLADE TURNING VANES - 0.86 0.83 0.77 DOUBLE BLADE TURNING VANES - 1.85 2.84 2.91 "S" TYPE SPUTTER VANES 0.61 0.65 - - NO VANES - UP TO 1200 FPM M/S 0.88 5.26 6.92 7.56 NO VANES - OVER 1200 FPM M/S) 1.26 6.22 8.82 9.24 TYPICAL DUCTWORK OFFSETS FOR OBSTRUCTIONS SCALE: NTS FASTENERS NOT PERMITTED TO PENETRATE EXHAUST OR DRYER VENT DUCTS. RETANGULAR DUCT, DEPRESSED TO AVOID AN OBSTRUCTION COEFFICIENT C W/H UH 0.121%1 0.15 0.25 0.30 1 1.0 0.26 0.30 0.33 035 0.10, 0.14 0.22 0.30 PAINT INTERIOR OF DUCT BLACK. USE NON -TOXIC PAINT N EQUAL TO NECK SIZE T-BAR 'N--ACOUSTICAL RETURN/EXHALIST AIR CEILING TILE DEVICE (SEE SCHEDULE) RETURN GRILLE DETAIL SCALE: NTS 16 OZ. COPPER OR 24 GA. ST. STEEL OR 040 ALUMINUM GOOSENECK SEAL ALL EDGES AFTER PIPE INSTALLATION ALL JOINTS TO BE SOLDERED OR HELIARCH WELDED FSEE SPECS. FOR TYPE OF ROOF CEILING CABINET EXHAUST FAN INTEGRAL BACKDRAFT DAMPER WIRE SUPPORTS TYPICAL OF 4. CEILING SEE PLAN FOR DUCT SIZE. CEILING CABINET EXHAUST FAN DETAIL La)voutl SCALE: NTS I Lavbutl Lid FLEXIBLE DUCT SAG NOT TO SEAL AIRTIGHT WITH GLASS EXCEED 1/2" PER 10 FEET MAX. FAB AND MASTIC (TYPICAL) CONICAL TYPE SPIN -IN FITTING WITH HANGER (TYP.) INSULATION VOLUME DAMPER SUPPORT STRAP FLEX DUCT DUCT AXIMUM ALLOWABLE M LENGTH OF FLEX. DUCT 61-0" SEAL AIRTIGHT ONTRACTOR SHALL PROVIDE A CEILING DIFFUSER STAND-OFF SPIN -IN SO THE INSULATE BACK AS BALANCING DAMPER HANDLE IS EASILY ACCESSIBLE FROM THE PER SPECIFICATIONS EXTERIOR OF THE INSULATION. CEILING LAY -IN CEILING T-BAR FRAME THROAT TO BE DIFFUSER AND HANGER A MINIMUM OF NOTE: 1 x DIAMETER PROVIDE TAPERED RECTANGULAR TO ROUND SIDE TAKEOFF FITTINGS WHERE DUCT DIMENSION DOES NOT PERMIT CONICAL FITTING. LAY -IN CEILING DIFFUSER DETAIL La)voutl SCALE: NTS Lavouti SEAL AIRTIGHT WITH GLASS FAB AND MASTIC CONICAL TYPE SPIN -IN FITTING WITH VOLUME DAMPER DRAWBAND CLAMP INSULATED FLEX DUCT CLASS1 TO AIR DEVICE 'j- MAIN BRANCH SEAL DUCT INSULATION TO INSULATED FLEX DUCT WITH GLASS FAB AND MASTIC CONTRACTOR SHALL PROVIDE A STAND-OFF SPIN -IN SO ACCESSIBLE FROM THE EXTERIOR OF THE INSULATION. THE BALANCING DAMPER HANDLE IS EASILY SPIN -IN COLLAR FITTING DETAIL W/ STAND-OFF T-La)voUtl SCALE: NTS BRANCH DUCT x PIVOT DAMPER (VD) 10- Uj (0 W BEARING QUADRANT LOCKING LEVER TRUNK DUCT ANGULAR TAP COLLAR EAIR FLOW (SUPPLY) AIR�FLOW (RETURN/EXHAUST) 0 A DUCTWORK BRANCH DETAIL SCALE: NTS M4 I Lavbutl MEP CONSULTING ENGINEERS SINCE 1977 FL REG NO. 3W9 2016 ALDEN RD. ORLANDO, FL 32803 (407) 2M-16M WWW.PEIFLA.COM PEI PROJECT f 22121 CAMPBELL + VAN DUSEN A R C. H I I F (7 Y 1, 1 � F 1',JT=Plr.R r)Fc,l_r4N www.CVDstudio.com CAMPBELL + VAN DUSEN Design Studio, LLC. 255 South Orange Avenue Suite # 1240 Orlando, Florida 32801 Phone: 407.930.6016 FL. Lic. No. AA26003339 ARCHITECT OF RECORD FRANK W. CAMPBELL AIA FL LIC NO. AR001 6053 COPY OF THIS PLAN IS NOT VALID UNLESS SIGNED, SEALED AND DATED BY THE ARCHITECT OF RECORD Ile . ..... ........ 0 E N 8��� No. 900" -k TATE OF 1% s vb�%. V, / .......... N �%NA\- \\N Taylor J. Lewis, PE, FL Reg. No. 9W18 COPY OF THIS PLAN IS NOT VALID UNLESS SIGNED, SEALED AND DATED BY THE ENGINEER OF RECORD LL_ I V) Z >_ 0 0- Uj C) < 0 C.") LjLj L.0 > __j + Lr) -'0 cle < LU LU I 0 > I LU "o No LO 13e CL < LU or-01 (C'2) r14 CONSTRUCTION DOCUMENTS 03.24.2023 PRINCIPAL IN CHARGE F... CAM . P.BE.L.L ................................................... . ...... . .. . PROJECT MANAGER M. TORRES ADVENT HEALTH WELL 65+ ZEPHYRHILLS 22-0328-01 MECHANICAL DETAILS M490 DIFFUSERS, REGOMRS AND GRIII I S SCHEDULE DUCTLESS SPLIT SYSTEM SINGLE PACKAGED A/C UNIT SCHEDULE MARK TYPE MAX. NC MAX. PD SIZE INCHES MATERIAL FINISH MANUFACTURER REMARKS PLAN MARK RTU-1 RTU-2 RTU-3 RTU-4 RTU-5 LEVEL (IN. ING.) (Face/Neck) MODEL NUMBER SCHEDULE CD-1 LOUVERED FACE SUPPLY DIFFUSER 14 0.05 24"x2e/8"0 ALUMINUM WHITE METALAIRE 5700 - PLAN MARK DSS-1/DCU-1 SYSTEM TYPE CURB NOT USED PACKAGE DX PACKAGE DX PACKAGE DX PACKAGE DX NOMINAL TONS 4 5 4 5 CD-2 LOUVERED FACE SUPPLY DIFFUSER 14 0.05 24-X24-/10-0 ALUMINUM WHITE METALAIRE 5700 - SYSTEM TYPE DX AREA SERVED - - - - CD-3 LOUVERED FACE SUPPLY DIFFUSER 15 0.04 12mxl2m/6"O ALUMINUM WHITE METALAJRE 5700 - NOMINAL TONS 1 TON SUPPLY AIR FLOW (CFM) 1600 2000 1600 2000 AREA SERVED Comm OUTSIDE AIR FLOW (CFM) 240 300 240 300 RG-1 RETURN/EXHAUST/TRANSFER GRILLE 25 0.073 2ex2e/22'x22* ALUMINUM WHITE METALAIRE CC5 - SUPPLY AIR FLOW (CFM) 400 CFMI COIL. F OUTSIDE AIR FLOW (CFM) 0 CFM ENT. AIR TEMP. (DB/WB) 95/80 95/80 95/80 95/80 lAff.- INDOOR UNIT LVG. AIR TEMP. (DB/WB) 60.1/57.5 59.3/57.7 60.1/57.5 59.3/57.7 1. ALL REGISTERS, GRILLES AND DIFFUSERS SHALL BE SECURELY SUPPORTED FROM THE STRUCTURAL MEMBERS AND NOT FROM THE ACOUSTICAL TILE CEILING. TOTAL CAPACITY (MBH) 48.4 59.25 48.4 59.25 2. ALL SUPPLY AIR DIFFUSERS ARE TO BE FOUR WAY THROW UNLESS OTHERWISE INDICATED ON THE FLOOR PLAN. COIL_ SENSIBLE CAPACITY (MBHI) 34.2 48.4 34.2 48.4 ENT. AIR TEMP (DB/WB) 75/60 FACE AREA 5.7 5.7 5.7 5.7 LVG. AIR TEMP (DB/WB) 55/55 ROWS/FP1 3/17 4/17 3/17 4/17 EXHAUST FAN SCHEDULE TOTAL GROSS CAP. (MBH) 12.0 EVAP. FAN: TAG TYPE AREA SERVED DRIVE CFM ESP. RPM MOTOR MANUFACTURER / MODEL WEIGHT NOTES EVAP. FAN: DRIVE TYPE DIRECT BELT DIRECT BELT CAMPBELL + VAN DUSEN W V/PH DRIVE TYPE DIRECT STATIC PRESS. (EXT./TOTAL) 0.50/- 0.50/- 0.50/- 0.50/- IIARCH IT ECTLI RE IN-ERIOR DIE315NI EF-1 CABINET JANITOR DIRECT 75 0.2 900 16 115/1 GREENHECK SP-A90 12 1,3,4 EXTERNAL/TOTAL S.P. MOTOR (HP/RPM) 3.0/2072 3.0/2241 3.0/2072 3.0/2241 EF-2 CABINET LAB DIRECT 175 0.25 660 68 115/1 MEENHECK SP-A200 17 1,3,4 HEATER: V~.CVDstudio.com EF-3 CABINET TOiLET DIRECT 1 75 0.2 900 1 16 115/1 GREENHECK SP-A9O 12 1-3 MOTOR (W/RPM) 30/- STAGES 1 1 1 1 CAMPBELL + VAN DUSEN Design Studio, LLC. EF-4 CABINET BIO DIRECT 75 0.2 900 16 1 115/1 GREENHECK SP-A90 12 1,3,4 VOLTS/0 208/1 KW 6.5 7.9 6.5 7.9 255 South Orange Avenue Suite # 1240 EF-5 CABINET TOILET DIRECT 75 0.2 900 16 115/1 GREENHECK SP-A90 12 1-3 MANUFACTURER CARRIER COMPRESSOR: Orlando, Florida 32801 EF-6 CABINET TOILET DIRECT 75 0.2 900 16 115/1 GREENHECK SP-A90 12 1-3 MODEL NUMBER DHMPHAQ12XA3 STAGES 1 1 1 1 Phone: 407.930.6016 1 1 1 OUTDOOR UNIT COMPRESSORS (NO./RLA/LRA) 1/13.7/83 1/16/110 1/13.7/83 1/16/110 FL. Lic. No. AA26003339 EF-7 ICABINET1 TOILET DIRECT 1 75 0.2 1 900 16 115/1 GREENHECK SP-A90 12 1-3 COMPRESSOR: UNIT POWER REQUIREMENTS: NOTES: STAGES VARIABLE 1. CONTRACTOR SHALL INSTALL EQUIPMENT TO COMPLY WITH REQUIRED ELECTRICAL CLEARANCES FOR THIS OR SURROUNDING EQUIPMENT. FIELD VOLTS/0 208/3 208/3 208/3 208/3 COORDINATE PRIOR TO INSTALLATION. COMPRESSORS (No./RLA/*LRA) 1/7/12.0 MCA 32 39 32 39 2. PROVIDE NTH INTEGRAL M07ION SENSOR. INTERLOCK NTH TIME -DELAY SET TO 10 MINUTES. COORDINATE WITH ELECTRICAL CONTRACTOR. 3. PROVIDE SOLID STATE FAN SPEED CONTROLLER FOR BALANCING, MOUNTED FAN CABINET. VOLTS/0 208/1 MFS 35 45 35 45 4. FAN SHALL RUN CONTINUOUSLY. INTERLOCK FAN WITH ASSOCIATED RTU. CONDENSER FAN: SEER/EER/IPLV 14/-/- 14/-/- 14/-/- 14/-/- FANS (No./FLA) 1/0.35 MANUFACTURER CARRIER CARRIER CARRIER CARRIER MODEL NUMBER 50FC-BO5J2M5 50FC-NO6J2M5 50FC-BO5J2M5 50FC-N06J2M5 VOLTS/0 208/1 OPERATING WEIGHT (LBS.) 732 719 732 719 ASHPAE 62.1 CONFORMANCE UNIT POWER REQUIREMENTS: NOTES: MCA 11 1. PROVIDE ALL UNITS NTH FACTORY THERMOSTAT, SINGLE POINT ELECTRICAL CONNECTION AND VENTILATION REQUIRED O.A. TOTAL O.A. FIRESTAT. UNIT ZONE AREA CLASSIFICATION RATE VENTILATION SUPPLIED MFS 15 2. PROVIDE ALL RTUS NTH 2 STAGE COOLING AND DEHUMIDIFICATION, NUMBERS OCCUR (SQ.FT.) CFM6Nj CFM/ (TOTAL CFM) (TOTAL CFM) EER/HSPF/SEER 12.0/-/20.8 3. PROVIDE 5 MINUTE AN11-CYCLE TIMER. (PEOPLE) PERS SQ.FT. 4. FILTERS SHALL BE MERV 8 PLEATED MEDIA (EXCEPT FOR RTU-12 MICH SHALL BE MERV 13), ARCHITECT OF RECORD RTU-2 20 f 1549 OFFICE 5 0.06 192 240 MANUFACTURER CARRIER DISPOSABLE TYPE IN A RIGID FRAME NTH A SU POR NG MAZ ACRO S BOTH ENTERING AND FRANK W. CAMPBELL AIA MODEL NUMBER 38MVRAQ12AA3 I EAVING SURFACES. SUPPLY ONE COMPLETE SET OF EXTRA FILTERS AFTER OWNER'S FINAL RTU-3 25 1586 OFFICE/1RECEPTION/CONFERENCE 5 0.06 220 300 ACCEPTANCE. FL LIC NO. AR001 6053 RTU-4 20 1840 OFFICE/CONFERENCE 5 0.06 210 240 MAX. LINE LENGTH (FT) 165 5. INSTALL DUCT SMOKE DETECTOR FURNISHED BY ELECTRICAL IN SUPPLY AIR DUCTS OF AIR HANDLING COPY OF THIS PLAN IS NOT VALID UNLESS SiGNED, __r 300 UNITS AS INDICATED ON DRAWINGS. DETECTOR TO SHUT DOWN UNIT MEN ACTIVATED. SEALED AND DATED BY THE ARCHITECT OF RECORD RTU-5 25 1570 OFFICE/CONFERENCE 5 0.06 220 MAX. PIPE ELEVATION (FT) 100 6. PROVIDE FLOAT SWITCH IN DRAIN PAN TO SHUT DOWN UNIT UPON DETECTION OF HIGH CONDENSATE OPERATING WEIGHT - INDOOR UNIT 29 LEVEL TO PROTECT FROM OVERFLOW. 7. PROVIDE ROOF CURB ADAPTER IF NECESSARY AND PROVIDE OUTSIDE AIR INTAKE HOOD WITH 1. ALL DUCTWORK SHALL BE KEPT SEALED TO PREVENT CONTAMINATION BY DUST OR OTHER DEBRIS DURING OPERATING WEIGHT - OUTDOOR UNIT 92 MOTORIZED 2-POS111ON DAMPER. CONSTRUCTION. SEAL THE END OF DUCTWORK NTH PLASTIC SHEETING AND DUCT TAPE. PROTECT ALL 8. CONTRACTOR SHALL INSTALL EQUIPMENT TO COMPLY WITH REQUIRED ELECTRICAL CLEARANCES FOR DUCTWORK STORED ON -SITE PRIOR TO FABRICATION AND INSTALLATION IN A SIMILAR FASHION. NOTES: THIS OR SURROUNDING EQUIPMENT. FIELD COORDINATE PRIOR TO INSTALLATION. 2. ALL EQUIPMENT SHALL BE SUPPLIED AND INSTALLED WITH PROVISIONS FOR IN -PLACE CLEANING AND 1. PROVIDE UNIT NTH FACTORY THERMOSTAT. 9. MECHANICAL CONTRACTOR TO PROVIDE STARTERS FOR UNITS NOT PROVIDED WITH BUILT-IN STARTERS OR CONTACTORS. MAINTENANCE TASKS IN ACCORDANCE NTH THE REQUIREMENTS OF ASHRAE STANDARD 62-89R. 2. PROVIDE 5 MINUTE ANTI -CYCLE TIMER. 10. MECHANICAL CONTRACTOR TO PROVIDE FUSED DISCONNECT SWITCHES NTH GROUND LUG FOR HVAC 3. PROVIDE REMOTE CONTROL & MONITORING WALL BOX EQUIPMENT. pMES4 3. CHANGE IN SPACE USE, CONTAMINANTS, OR OPERATION MAY REQUIRE A RE-EVAWATION OF THE DESIGN NTH STANDARD ALARMS & THE FOLLOWING OPTIONAL 6� . ................ 11. SINGLE POINT OF CONNECTION ON UNITS SHALL BE FACTORY PROVIDED WITH PROPER FUSES OR NS' AND IMPLEMENTATION OF NEEDED CHANGES. ALARMS: FILTER ALARM, WATER DETECTED ALARM. 4. VENDOR SHALL PROVIDE ADEQUATELY SIZED CIRCUIT BREAKERS TO PROTECT INDIVIDUAL DOWNSTREAM COMPONENTS SUCH AS HEATERS AND FAN MOTORS, AND WRING FROM SINGLE POINT OF CONNECTION TERMINAL BLOCK TO ALL DOWNSTREAM gooiB 4. THIS TABLE IS INTENDED TO PROVIDE VENTILATION CALCULATIONS IN COMPLIANCE WITH ASHRAE CONDENSATE PUMP WITH CHECK VALVE. HEATERS AND FAN MOTORS. 62.1-2013. THESE CALCULATIONS ARE IN LIEU OF THE REQUIREMENTS LISTED IN THE FLORIDA 5. PRIMARY SYSTEM ELECTRICAL POWER IS THROUGH 12. MEN COMPONENTS ARE SHIPPED SEPARATELY FOR FIELD INSTALLATION, CONTRACTOR SHALL INCLUDE MECHANICAL CODE TABLE 403.3. THIS ALTERNATIVE IS IN ACCORDANCE WITH THE FLORIDA MECHANICAL CONDENSING UNIT THEN TO INDOOR UNIT. ALL COST RELATED TO WIRING AND OVERCURRENT PROTECTION REQUIREMENTS. STATEOF -AF. CODE SECTION 403.2. 6. CONTRACTOR SHALL INSTALL EQUIPMENT TO COMPLY 13. PROVIDE UNITS NTH ECONOMIZERS. :"_ -Z� ­" L OR\ .0 WITH REQUIRED ELECTRICAL CLEARANCES FOR THIS OR . ........ OCCUPANCY FOR THESE ZONES HAS BEEN CORRECTED DUE TO INTERMITTENT SPACE USAGE. BASED ON SURROUNDING EQUIPMENT. FIELD COORDINATE PRIOR TO //j; %910NAA, NORMAL OCCUPANCY, PEAK OCCUPANCY AND THE VOLUME OF THE SPACE, THE ZONE POPULATION HAS INSTALLATION. BEEN AVERAGED OVER A TIME PERIOD DETERMINED IN ACCORDANCE WITH ASHRAE STANDARD 62.1-2013, SECTION 6.2.6.2. Taylor J. Lewis, PE, FL Reg. No. 90018 COPY OF THIS PLAN IS NOT VALID UNLESS SIGNED, SEALED AND DATED BY THE ENGINEER OF RECORD LL_ 0 r LIJ CL _T_ ry 0 U C/) > Uj LU _j 0 CQ + -F _j I-- L0 j U *_0 Cie < LU LU >_ 0 > -T- 0 C) LU C1_ rL-U4 or-',) (Iyyl) CONSTRUCTION DOCUMENTS 03.24.2023 NO. DATE DESCRIPTION PRINCIPAL IN CHARGE F. CAMPBELL .................................................................... PROJECT MANAGER M. TORRES .................................................................... ADVENT HEALTH WELL 65+ ZEPHYRHILLS 22-0328-01 MEP CONSULTIING MECHANICAL ENGINEERS SINCE 1977 SCHEDULES FIL REG NO. 3089 2016 ALDEN RD. ORLANDO, FL 32803 (407) 246-1688 WWW.PEIFLA.COM M500 PEI PROECT f. 221211 4 PAMENT CARE AREA SYMBOL LEGEND 4�> GENERAL CARE - CATEGORY 2 NOTES: 1. THERE ARE NO CRITICAL OR WET PATIENT AREAS IN THE SCOPE OF WORK. 2. GENERAL PATIENT CARE AREAS REQUIRE A WRING METHOD WTH A REDUNDANT GROUND AS PER ARTICLE 517.13 OF THE NEC. GROUNDING 0 FALL RECEPTACLES, LIGHTING AND FIXED EQUIPMENT IN PATIENT CARE AREAS SHALL COMPLY WTH NEC ARTICLE 517.13 (A) AND (B) TESTING, INSPECTIONS - AND CERTIFICATIONS: A. EQUIPOTENTIAL GROUNDING TEST FOR PATIENT CARE AREAS NFPA 99, 2018 EDITION, SECTION 6.3.3 REQUIRES TESTING OF NEW CONSTRUCTION AND EXISTING CONSTRUCTION AND REPEATED WIEN MAJOR RENOVATIONS OCCUR. MOST EXISTING FACIU11ES HAVE NO RECORDS OF EXISTING CONDITIONS, HOWEVER, LOGS SHOULD BE CHECKED ANNUALLY BY AHCA. THEREFORE, ALL PATIENT AREAS WTHIN ANY SCOPE OF WORK WLL NEED TO BE TESTED BY THE CONTRACTOR. (ALSO SEE NEC 517-13, 14 & 16). B. WHAT NEEDS TO BE TESTED? ONLY METAL CONDUCTIVE SURFACES LIKELY TO BECOME ENERGIZED WTHIN THE PATIENT VICINITY. PATIENT VICINITY IS DEFINED AS: 1. AN AREA MERE PATIENTS ARE NORMALLY CARED FOR. 2. THE SPACE NTH SURFACES LIKELY TO BE CONTACTED BY PATIENT OR ATTENDANT TOUCHING THE PATIENT. (BEDS, HEADWALLS, A/C UNITS, SINK, TRIM, ETC.) 3. IN A PATIENT ROOM BASICALLY THE ENTIRE ROOM INCLUDING TOILET/SHOWER ROOM. PATIENTS SHOULD BE IN WHEELCHAIRS OR SITTING IN CHAIRS. C. 1. 2. D. 2. a. b. C. d. e. f. 3. 4. E. b. C. F. 1. 2. G. 1. 2. 3. 4. 60-0w 69-Ow PATIENT BED 31-6" 6'-On 7'-6- VERTICALLT ABOVE FLOOR I TYPICAL PATIENT ROOM PATIENT VICINITY DISTANCES GROUND TEST DOES NOT INCLUDE: SMALL WALL MOUNTED CONDUCTIVE SURFACES, TOWEL AND SOAP DISPENSERS, MIRRORS, BED PANS, ETC. LARGE METAL SURFACES NOT LIKELY TO BECOME ENERGIZED, WNDOW FRAMES, DOOR FRAMES, FLOOR DRAINS AND MOVABLE CABINETS. TEST METHOD: BOTH VOLTAGE AND IMPEDANCE MEASUREMENTS MUST BE MADE. ALL MEASUREMENTS MUST BE TAKEN TO A REFERENCE POINT OR IN NEAR AREA BEING TESTED. GROUND BAR IN A PANEL SERVING AN AREA. GROUND JACK IF ONE EXISTING. ESTABLISHED GROUND BUS. AN ALL METAL COLD WATER PIPE. BE CAREFUL OF WASTE PIPE OR SPRINKLER PIPE BECAUSE OF NO -HUB AND VITAULIC FITTINGS. GROUNDING CONTACT OR A RECEPTACLE THAT IS POWERED FROM A DIFFERENT CIRCUIT FROM THE RECEPTACLE UNDER TEST. VOLTAGE MEASUREMENTS ARE TO BE MADE BETWEEN REFERENCE POINT AND APPROPRIATE CONDUCTIVE SURFACES INCLUDING RECEPTACLE GROUND CONTACTS. IMPEDANCE MEASUREMENTS ARE TO BE MADE ONLY BETWEEN REFERENCE POINT AND RECEPTACLE GROUND CONTACTS. REQUIRED RESULTS: NEW/EXISTING CONSTRUCTION VOLTAGE - MAXIMUM 20MV +/-20% (24 TO 20MV) IMPEDANCE - MAXIMUM 0.1 OHM +/-20% (0.12 TO 0.1 OHM) IMPEDANCE (ISOLATED GROUND) - MAXIMUM 0.2 OHM +/- 20% (0.28 TO 0.12 OHM) GENERAL COMMENTS: THE IMPEDANCE MEASUREMENTS FOR NEW AND EXISTING CONSTRUCTION SHALL BE THE RATIO OF 60HZ VOLTAGE DEVELOPED BETWEEN A POINT UNDER TEST AND A REFERENCE POINT TO 60HZ CURRENT APPLIED TO THE POINT UNDER TEST. IF EXISTING CONSTRUCTION 60HZ OR DC MAY BE USED, AND THE TEST MUST NOT ENDANGER PATIENT. ALSO, TESTS MUST INCLUDE CORRECT POLARITY OF HOT AND NEUTRAL AND GROUNDING BLADE RETENTION FORCE (40Z. MIN.) JEST EQUIPMENT: USE A MILLIVOLT METER DESIGNED FOR THIS PURPOSE NTH 1 K OHM INPUT RESISTANCE (+/-10%) AT FREQUENCIES OF 1000HZ OR LESS. USE A HIGH Z MV METER WTH EXTERNAL FREQUENCY SHAPING NETWORK. RECEPTACLE POLARITY TESTER. RETEN11ON FORCE TESTER OR MANUFACTURER'S DATA VERIFYING COMPLIANCE THROUGH U.L, NEMA OR OTHER TESTS. ELECTRICAL SPECIFICA11ONS GENERAL PROVISIONS A. PROVIDE ALL LABOR, MATERIALS AND EQUIPMENT FOR A COMPLETE AND PROPERLY OPERATING ELECTRICAL SYSTEM. INCLUDE NECESSARY FEES AND PERMITS WITHIN BASE BID. ARCHITECTURAL, MECHANICAL, PLUMBING AND FIRE PROTECTION DRAWNGS ARE CONSIDERED PART OF THESE CONSTRUCTION DOCUMENTS FOR COORDINATION, EQUIPMENT CONNECTION, HEIGHTS AND LOCATIONS. B. CODES AND STANDARDS: ALL ELECTRICAL WORK SHALL BE IN STRICT COMPLIANCE WTH THE PROVISIONS OF THE LOCAL GOVERNMENT AUTHORITY, THE NATIONAL ELECTRIC CODE 2017 EDITION; SEVENTH ED11ION (2020) FLORIDA BUILDING CODE, THE FLORIDA FIRE PREVENTION CODE 2020 EDITION, NATIONAL FIRE ALARM CODE NFPA 72 2016 EDITION AND THE CODES AND STANDARDS REFERENCED THEREIN. ALL MATERIALS SHALL BE NEW AND FREE FROM DEFECTS, AND SHALL BEAR THE UNDERWRITER'S LABEL. C. CONTRACTOR SHALL THOROUGHLY INVESTIGATE SITE BEFORE BIDDING. NO CHANGES WLL BE ALLOWED IN CONTRACT PRICE FOR WORK REQUIRED TO COMPLY WTH EXISTING CONDITIONS. D. ALL ELECTRICAL WORK SHALL BE DONE IN A NEAT AND WORKMANLIKE MANNER. E. CONTRACTOR SHALL SCHEDULE AH DOWN -TIME NTH THE OWNER PRIOR TO BEGINNING THE WORK. PREMIUM /OVERTIME RATES MAY BE REQUIRED AND MUST BE INCLUDED IN BASE BID. F. CONTRACTOR SHALL THOROUGHLY REVIEW CONSTRUCTION DOCUMENTS AND WALK SITE. MEN CONFLICTS ARISE WTHIN CONSTRUCTION DOCUMENTS, CONTRACTOR SHALL NOTIFY ENGINEER PRIOR TO SUBMITTING A BID. SUBMISSION OF A BID SHALL INDICATE THAT CONTRACTOR THOROUGHLY REVIEWED CONSTRUCTION DOCUMENTS AND WALKED THE SITE PRIOR TO BID SUBMISSION. MEN ENGINEER IS NOT AVAILABLE, OR TIME DOES NOT PERMI TCON TRACTOR SHALL INCLUDE THE MOST STRINGENT (COSTLY) REQUIREMENTS WTHIN BASE BID. G. CONTRACTOR SHALL COORDINATE WTH UTILITY COMPANY AND TELECOMMUNICATION COMPANY FOR LOCATIONS, REQUIREMENTS AND CONDUITS ROUTING PRIOR TO COMMENCEMENT OF WORK OR ROUGH -IN. H. ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING MANUFACTURERS, SUB- CONTRACTORS, VENDORS AND SUPPLIERS, WTH A COMPLETE SET OF THESE DOCUMENTS PRIOR TO SUBMITTING A BID. 1. GUARANTEE ALL ELECTRICAL SYSTEM MATERIALS AND WORKMANSHIP TO BE FREE FROM DEFECTS FOR A PERIOD OF ONE (1) YEAR FROM THE DATE OF FINAL ACCEPTANCE AND PROPERLY CORRECT LATENT DEFECTS ARISING WTHIN THIS PERIOD UPON NOTIFICATION BY THE OWNER'S REPRESENTATIVE WTHOUT ADD11IONAL COMPENSATION. J. DAILY REMOVE REFUSE AND DEBRIS ACCUMULATING FROM ELECTRICAL CONSTRUCTION AND PRIOR TO ACCEPTANCE OF THIS WORK, LEAVE THE PREMISES "BROOM CLEAN" INSOFAR AS AFFECTED BY ELECTRICAL WORK. K. ELECTRICAL CONTRACTOR SHALL EXAMINE ARCHITECTURAL, MECHANICAL, PLUMBING AND FIRE PROTECTION DRAWNGS FOR ES11MATING AND CONSTRUCTION OF THIS PROJECT. SUBMISSION OF A PROPOSAL SHALL BE CONSTRUED AS EVIDENCE THAT SUCH EXAMINATION HAS BEEN MADE AND LATER CLAIMS FOR LABOR, EQUIPMENT OR MATERIALS REQUIRED FOR CONNECTING AND ENERGIZING EQUIPMENT SHOWN ON THOSE DRAWNGS WLL NOT BE RECOGNIZED. ELECTRICAL CONTRACTOR SHALL COMMUNICATE DISCREPANCIES TO ENGINEER PRIOR SUBMITTING A BID. L. EQUIPMENT AND DESIGN OF SYSTEMS INDICATED ON THE DESIGN DRAWNGS AND WTHIN THESE SPECIFICATIONS SHALL BE CONSIDERED AS "SPECIFIED STANDARD" OF QUALITY. NO SUBSTITUTIONS SHALL BE MADE WTHOUT WRITTEN APPROVAL OF THE ENGINEER AT LEAST 10 DAYS PRIOR TO BID DATE. ANY DEVIATION FROM SPECIFIED EQUIPMENT THAT AFFECT THE INSTALLATION, OPERATION, PERFORMANCE, QUALITY OR LONGEVITY OF THE ELECTRICAL SYSTEMS AS DEFINED HEREIN, SHALL BE REPLACED BY THE ELECTRICAL CONTRACTOR NTH NO ADDITIONAL COST TO THE CLIENT, IN ADDITION, ELECTRICAL CONTRACTOR SHALL PROVIDE THE ENGINEERING WTH PHOTOMETRIC FLOOR PLANS FOR ANY LIGHTING FIXTURES CHANGES FOR APPROVAL AT LEAST 10 DAYS PRIOR TO BID DATE. BASIC MATERIALS AND METHODS A. RACEWAYS AND FITTINGS: ALL RACEWAYS AND FITTINGS SHALL BE GALVANIZED RIGID STEEL OR INTERMEDIATE METAL CONDUIT WTH LOCKNUTS AND BUSHINGS, NTH THE EXCEPTION THAT WERE SPECIFICALLY ALLOWED BY THE NATIONAL ELECTRICAL CODE AND APPLICABLE LOCAL CODES. ELECTRICAL METALLIC TUBING (E.M.T) MAY BE USED FOR ALL INTERIOR EXPOSED AND CONCEALED WORK WHERE IT IS NOT SUBJECT TO PHYSICAL DAMAGE OR CORROSION. FITTINGS SHALL BE STEEL SET SCREW TYPE. PVC SCHEDULE 40 WTH TAR COATED GALVANIZED RIGID STEEL ELBOWS SHALL BE USED FOR BELOW GRADE INSTALLATIONS. MC CABLE SHALL BE ALLOWED MEN APPROVED BY TENANT AND LANDLORD AND IT SHALL BE INSTALLED AS PER ARTICLE 330 OF THE NEC, NO BX CABLE ALLOWED. INSTALL EXPANSION FITTINGS IN RACEWAYS EVERY 200' LINEAR RUN OR WHEREVER STRUCTURAL EXPANSION JOINTS ARE CROSSED. FOR MEDICAL, DENTAL AND SIMILAR OFFICES AS DEFINED BY NEC ARTICLE 517, NO NON-METALIC RACEWAYS SHALL BE USED ANYWHERE AND ONLY MC CABLE LISTED FOR HEALTHCARE USE MAY BE USED FOR RECEPTACLE CIRCUITS, FIXED EQUIPMENT CIRCUITS, SWTCH LEGS AND LIGHT FIXTURE MIPS. B. PROVIDE PULL STRING IN ALL EMPTY CONDUITS. C. FINAL CONNECTIONS TO MOTORS OR EQUIPMENT SUBJECT TO VIBRATION SHALL BE MADE UP WTH GREENFIELD IN DRY LOCATIONS AND WTH JACKETED, LIQUID -TIGHT, FLEXIBLE, GALVANIZED STEEL CONDUIT IN WET OR DAMP LOCATIONS. D. CONDUCTORS: FEEDER AND BRANCH CIRCUIT CONDUCTORS SHALL BE THWN-2 COPPER (MINIMUM SIZE #12 UNLESS OTHERWSE NOTED). PER NEC 110.14 (c)(1)(a)Ab) CONDUCTOR AMPACITY BASED ON 60*C COLUMN FOR CIRCUITS RATED 100 AMPS OR LESS, OR #1 AWG OR LESS CONDUCTORS AND 75*C COLUMN FOR CIRCUITS RATED OVER 100 AMPS, OR LARGER THAN #1 AWG CONDUCTORS PER TABLE NEC 310.15(B)(16). NO ALUMINUM SHALL BE PERMITTED UNLESS SPECIFICALLY NOTED OTHERNSE. INSTALL ALL WRING IN CONDUIT OR APPROVED RACEWAYS UNLESS OTHERWSE INDICATED. PROVIDE #10 AWG FOR BRANCH CIRCUITS OVER 100 FEET IN LENGTH TO ACCOUNT FOR VOLTAGE DROP. PROVIDE #10 GROUND TO CORRESPOND. ALL BRANCH CIRCUITS SHALL CARRY AN EQUIPMENT GROUNDING CONDUCTOR, AND BE WIRED WTH COLOR -CODED WIRE WTH SAME COLOR USED FOR A PHASE THROUGHOUT. COLOR -CODE SHALL BE AS FOH OWS: 120/208 VOLT - PHASE A - BLACK PHASE 8 - RED PHASE C - BLUE NEUTRAL - WHITE GROUND - GREEN. PUSH -IN WIRE CONNECTORS ARE NOT PERMITTED. E. LOCATE ALL DEVICES AND EQUIPMENT MERE SHOYM ON DRAWNGS. ALL DIMENSIONS SHOINN ON THE DRAWNGS ARE FROM FINISHED FLOOR TO THE CENTER OF THE DEVICE UNLESS OTHERWSE INDICATED. STANDARD MOUNTING HEIGHTS ARE AS FOLLOWS: DEVICES HEIGHT AFF AT DEVICE CENTER ELECTRICAL OUTLETS 18, ELECTRICAL OUTLETS ABOVE COUNTER 42" TELEPHONE 18w WALL TELEPHONE 46" LIGHT SWTCHES 42" FIRE ALARM DEVICES 80" TO BOTTOM OF GLASS EXIT SIGNS AS NECESSARY SPECIAL DEVICES AS NECESSARY NOTE: ELECTRICAL CONTRACTOR SHALL FIELD VERIFY AND COORDINATE WTH PROJECT SUPERINTENDENT FOR OVER COUNTER OUTLETS MOUNTING HEIGHT AND DIREC11ON (VERTICAL OR HORIZONTAL) PRIOR TO ROUGH -IN. F. DISCONNECT SWTCHES: HEAVY DUTY, FUSED OR NON -FUSED AS CALLED FOR ON DRAWNGS. PROVIDE SOLID NEUTRAL CONNEC11ON MERE REQUIRED. USE NEMA-1 INDOORS AND NEMA-3R OUTDOORS. ALL DISCONNECT SWTCHES SHALL BE PROVIDED NTH GROUND KIT. G. PROVIDE PANELBOARDS OF THE DEAD FRONT TYPE, NO LESS THAN 20 INCHES WDE AND 5 3/4 INCHES DEEP WTH QUANTITY OF BRANCH CIRCUITS/CIRCUIT BREAKERS AS INDICATED ON THE PANELBOARD SCHEDULE NTH THE VOLTAGE, PHASE AND AMPERE RATING AS REQUIRED. ALL PANELBOARDS SHALL HAVE PHASE SEQUENCE CIRCUITS AND BOLT -ON CIRCUIT BREAKERS. MAIN BREAKERS SHALL BE MOLDED CASE. CIRCUIT BREAKERS FEEDING HVAC LOADS SHALL BE HACR TYPE THAT SERVE AS DISCONNECTING MEANS FOR EQUIPMENT SHALL BE PROVIDED WTH PERMANENTLY INSTALLED LOCK -OFF KIT. TYPEWRITTEN PANEL DIRECTORIES SHALL BE PROVIDED AT COMPLETION OF THE PROJECT. H. ELECTRICAL CONTRACTOR SHALL REVIEW ONE LINE POWER RISER DIAGRAM IN CONJUNCTION NTH SWTCHGEAR MANUFACTURER REPRESENTATIVE TO CROSS REFERENCE POWER RISER WTH PANEL SCHEDULES AND VERIFY VOLTAGES, AMPS, LUGS SIZES/NUMBER AND CABINETS DIMENSIONS PRIOR TO SUBMITTING A BID. 1. EXERCISE CARE IN CONNECTING THE VARIOUS ELECTRICAL LOADS TO THE PANELS IN ORDER TO ARRIVE AT A REASONABLE BALANCE BETWEEN LOADS IN EACH PHASE AT EACH PANEL MAKE TESTS AND ADJUST LOADS AT EACH PANEL TO RESULT IN REASONABLY BALANCED LOAD CONDITION. SATISFACTORY TO THE U11LITY COMPANY. ENGINEER, OYMER AND INSPECTION AGENCIES. DOCUMENT ALL SAID LOAD ADJUSTMENTS. J. MANUFACTURERS: BASE OF DESIGN IS SQUARE D, EQUAL PRODUCTS BY GENERAL ELECTRIC, SIEMENS OR CUTLER HAMMER WLL BE CONSIDERED. K. MATERIALS SHALL BE NEW AND UNUSED AND THE CATALOGUED PRODUCTS OF MANUFACTURERS REGULARLY ENGAGED IN THE PRODUCTION OF SUCH MATERIALS. THE MATERIALS SHALL BE OF THE MANUFACTURER'S LATEST STANDARD DESIGN THAT COMPLIES WTH THE SPECIFICATION REQUIREMENTS. ALL MATERIALS SHALL BE PROVIDED WTH UL LABELS. M. LIGHTING M.1. LIGHTING FIXTURES SHALL BE AS SHOYM ON THE DRAWNG AND SHALL BE FURNISHED WTH LAMPS INSTALIfD. M.2. ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING CEILING TYPES PRIOR TO ORDERING LIGHT FIXTURES. M.3. LIGHT FIXTURES SHALL BE SUPPORTED NTH #12 GAUGE WRE FROM BUILDING STRUCTURE AND NOT FROM CEILING GRID. SECURE TWO OPPOSITE CORNERS TO STRUCTURE. M.4. LUMINAIRES MUST NOT BE INSTALLED LESS THAN 1 2/2 INCHES BELOW METAL ROOF DECKING. N. ALL GROUNDING SHALL CONFORM TO ARTICLE 250 OF THE NEC REQUIREMENTS. IN ADDITION THERETO AS IMPOSED BY THE DRAWNGS AND THE LOCAL CODE ENFORCEMENT AUTHORITIES HAVING JURISDICTION. 0. SUBMITTALS: SUBMIT ELECTRONIC SUBMITTALS VIA E-MAIL FORMATTED AS PDF FILE. P. CONDUIT PENETRATIONS THROUGH FIRE RATED PARTITIONS SHALL BE SEALED USING AN UL APPROVED SYSTEM. REFER TO ARCHITECTURAL FLOOR PLAN FOR LOCA11ON OF FIRE RATED PARTITIONS. PROVIDE ACOUSTICAL FOAM SEALANT AT ALL DEVICES ON DEMISING PARTITIONS. IF PARTITION IS FIRE RATED, PROVIDE FIREPROOF COMPOUND ON BACK AND SIDES OF THE BOX. MERE TELEPHONE AND ELECTRICAL OUTLETS APPEAR ON PLANS AS BACK TO BACK, OUTLETS SHALL BE STAGGERED TO REDUCE NOISE TRANSMISSION. WERE WALLS AND PARTITIONS ARE REQUIRED TO HAVE A MINIMUM OF 1-HOUR FIRE -RESISTANCE RATING, BOXES SHALL BE SEPARATED BY A MINIMUM HORIZONTAL DISTANCE OF 24 INCHES OR PROTECTED WTH UL LISTED PUTTY PADS. Q. ELECTRICAL CONTRACTOR SHALL REVIEW THE ARCHITECTURAL DRAWNGS FOR DEVICES EXACT LOCATIONS, MOUNTING HEIGHTS AND QUANTITIES PRIOR TO BID AND PRIOR TO ROUGH -IN. NOTIFY THE ENGINEER IMMEDIATELY IF ANY DISCREPANCIES ARE FOUND. R. REVIEW AND COORDINATE WTH MECHANICAL CONTRACTOR DRAWNGS FOR EQUIPMENT, CONDUIT, DEVICES, ETC. REQUIRED FOR A COMPLETE AND OPERATING HVAC SYSTEM. LOW VOLTAGE CONTROL WRING FURNISHED AND INSTALLED BY DIVISION 15. CHECK ALL MOTORS AND ROTATING EQUIPMENT FOR PROPER ROTATION. S. FINAL QUANTITY OF EXIT AND EMERGENCY LIGHTS TO BE DETERMINED BY FIRE MARSHALL INCLUDE CONTINGENCY FOR 6 ADDITIONAL EXIT LIGHTS AND 6 ADDITIONAL EMERGENCY LIGHTS IN BASE BID. T. PROVIDE BACK BOXES AND RACEWAY FOR DOOR ACCESS CARD READERS AND ELECTRIC STRIKES AS PER SECURITY CONTRACTOR DIRECTIONS. PROVIDE 120VAC TO EACH ELECTRIC STRIKE DOOR LOCATION AND TO ACCESS CONTROL SYSTEM PANEL ACCESS CONTROL SYSTEM MUST DEACTIVATE OR OPEN ANY DOOR LOCKING MECHANISM AND REMAIN IN FAIL SAFE POSITION WHENEVER FIRE ALARM SYSTEM IS ACTIVATED OR BUILDING POWER FAILS. PROVIDE "PUSH-TO-EXIr PUSHBUTTON AND MOTION DETECTOR AT EACH ACCESS DOOR LOCATION. INTERLOCK NTH FIRE ALARM SYSTEM. ANY CARD READERS PREVENTING FREE EGRESS SHALL BE IN ACCORDANCE NTH SECTION 1010.1.9.9 OF CHAPTER 10 OF THE FLORIDA BUILDING CODE. U. ELECTRICAL CONTRACTOR MAY COMBINE CIRCUITS IN A COMMON RACEWAY AS LONG AS CONDUCTORS ARE DERATED AS PER NEC TABLE 310-15. SHARED NEUTRAL SHALL NOT BE ALLOWED UNLESS OTHERNSE INDICATED. CIRCUITS SHARING A COMMON NEUTRAL MUST HAVE COMMON TRIP CIRCUIT BREAKERS TO ALLOW ALL TO BE TURNED OFF SIMULTANEOUSLY, AS PER NEC 210.4(B). V. ELECTRICAL CONTRACTOR SHALL INCLUDE CORE DRILLING, CUTTING AND PATCHING FOR THE INSTALLATION OF HIS/HER WORK WTHIN BASE BID. W. CLEAN ALL NEW AND EXISTING LIGHT FIXTURES, LAMPS AND LENSES AND PANELBOARD INTERIORS PRIOR TO FINAL ACCEPTANCE. X. PROVIDE DISK FILE ON CAD 2015 OR NEWER RELEASE WTH ACCURATE ELECTRICAL RECORD DRAWNGS AT THE COMPLETION OF THE PROJECT. Y. CONTRACTOR REPRESENTS THAT HIS BID IS BASED UPON THE MANUFACTURER'S MATERIALS AND EQUIPMENT DESCRIBED IN THE CONTRACT DOCUMENTS. Z. ELECTRICAL CONTRACTOR SHALL FILL UTILITY SERVICE INFORMATION LOAD FORMS AND BUILDING DEPARTMENT ELECTRICAL PERMIT FORMS. AA. ELECTRICAL CONTRACTOR SHALL INSTRUCT OWNER REPRESENTATIVE REGARDING EQUIPMENT OPERA11ON AND MAINTENANCE AT COMPLETION OF WORK. PROVIDE OWNER NTH ALL MANUALS PERTAINING TO THE PROJECT. AB. LOW VOLTAGE CABLES FOR SECURITY SYSTEM, AV SYSTEM, TELEPHONE SYSTEM AND DATA SYSTEM ARE NOT PART OF THIS ENGINEER'S SCOPE OF WORK. ELECTRICAL CONTRACTOR SHALL COORDINATE NTH LOW VOLTAGE VENDOR(S) FOR BOXES AND RACEWAYS LOCATIONS, SIZES AND ROUTING PRIOR TO ROUGH -IN. AC. MINIMUM EMERGENCY ILLUMINATION SHALL BE PROVIDED FOR A PERIOD OF 1 1/2 HOURS IN THE EVENT OF FAILURE OR NORMAL LIGHTING, WTHIN THE WORK AREAS. EMERGENCY LIGHTING FACIU11ES SHALL BE ARRANGED TO PROVIDE INITIAL ILLUMINATION THAT IS AT LEAST AN AVERAGE OF 1 FOOTCANDLE (10 LUX) AND A MINIMUM AT ANY POINT OF 0.1 FOOTCANDLE (1 LUX) MEASURED ALONG THE PATH OF EGRESS AT FLOOR LEVEL 'Elm, ENERGY CONSERVAT'ION CODE COMPLIANCE 1. THIS DESIGN COMPLIES WTH F.B.C. ENERGY CONSERVATION SEVENTH EDITION (2020) CHAPTER 4, SECTION C405 FOR ELECTRICAL POWER AND LIGHTING SYSTEMS. 2. THIS DESIGN COMPLIES WTH 7TH EDITION (2020) OF F.B.C. ENERGY CONSERVATION CHAPTER 4 ARTICLE C405.5.3 FOR FEEDER AND BRANCH CIRCUIT VOLTAGE DROP. 3. WTHIN 30 DAYS AFTER THE DATE OF SYSTEM ACCEPTANCE, RECORD DRAWINGS OF THE ACTUAL INSTALLATION SHALL BE PROVIDED TO THE BUILDING OWNER, INCLUDING: a. A SINGLE DIAGRAM OF THE BUILDING ELECTRICAL DISTRIBUTION SYSTEM AND b. FLOOR PLANS INDICATING LOCATION AND AREA SERVED FOR ALL DISTRIBUTION. (REF. FBC-EC C405.5.4.1 - 7TH EDITION). 4. AN OPERATING MANUAL AND MAINTENANCE MANUAL BE PROVIDED TO THE BUILDING OWNER. THE MANUALS SHALL INCLUDE� AT A MINIMUM, THE FOLLOWNG. a. SUBMITTAL DATA STATING EQUIPMENT RATING AND SELECTED OPTIONS FOR EACH PIECE OF EQUIPMENT REQUIRING MAINTENANCE. b. OPERATION MANUALS AND MAINTENANCE MANUALS FOR EACH PIECE OF EQUIPMENT REQUIRING MAINTENANCE. REQUIRED ROUTINE MAINTENANCE ACTIONS SHALL BE CLEARLY IDENTIFIED. c. NAMES AND ADDRESSES OF AT LEAST ONE QUALIFIED SERVICE AGENCY. (REF: FBC-EC 405.5.4.2 - 7TH EDITION). LIGHTING COMMISSIONING LIGHTING SYSTEM FUNCTIONAL TESTING CONTROLS FOR AUTOMATIC UGFITING SYSTEMS SHALL COMPLY WTH SECTION C408.3. FUNCTIONAL TESTING TESTING SHALL ENSURE THAT CONTROL HARDWARE AND SOFTWARE ARE CALIBRATED, ADJUSTED, PROGRAMMED AND IN PROPER WORKING CONDIT10N IN ACCORDANCE WTH THE CONSTRUCTION DOCUMENTS AND MANUFACTURER'S INSTALLATION INSTRUCTIONS. FUNCTIONAL TESTING SHALL BE PERFORMED BY CONTRACTOR AND MANUFACTURER'S REPRESENTATIVE IN THE PRESENCE OF THE CLIENT REPRESENTATIVE AT THE COMPLETION OF THE PROJECT. SCHEDULE A SECOND TESTING WTH ONSIER REPRESENTATIVE AFTER FACILITY HAS BEEN IN OPERATION FOR TWO OR THREE MONTHS. MERE REQUIRED BY THE CODE OFFICIAL, AN APPROVED PARTY INDEPENDENT FROM THE DESIGN OR CONSTRUCTION OF THE PROJECT SHALL BE RESPONSIBLE FOR THE FUNCTIONAL TESTING AND SHALL PROVIDE DOCUMENTATION TO THE CODE OFFICIAL CERTIFYING THAT THE INSTALLED LIGHTING CONTROLS MET THE PROVISIONS OF SECTION C405. FOR OCCUPANT SENSORS, TIME SWTCHES, PROGRAMMABLE SCHEDULE CONTROL PHOTOSENSORS OR DAY LIGHTING CONTROLS THE FOLLOWNG PROCEDURES SHALL BE PERFORMED. 1. CONFIRM THAT THE PLACEMENT, SENSITIVITY AND TIME-OUT ADJUSTMENTS FOR OCCUPANT SENSORS YIELD ACCEPTABLE PERFORMANCE. 2. CONFIRM THAT THE TIME SWTCHES AND PROGRAMMABLE SCHEDULE CONTROLS ARE PROGRAMMED TO TURN THE LIGHTS OFF. 3. CONFIRM THAT THE PLACEMENT AND SENSITIVITY ADJUSTMENTS FOR PHOTOSENSOR CONTROLS REDUCE ELECTRIC LIGHT BASED ON THE AMOUNT OF USABLE DAYLIGHT IN THE SPACE AS SPECIFIED. EXISTING CONDITIONS GENERAL NOTES 1. VISIT AND CAREFULLY EXAMINE THOSE PORTIONS OF THE BUILDING AND SITE AFFECTED BY THIS WORK BEFORE SUBMITTING PROPOSALS, SO AS TO BECOME FAMILIAR WTH EXISTING CONDITIONS AND DIFFICULTIES THAT WLL AFFECT EXECUTION OF THE WORK. SUBMISSION OF A PROPOSAL WILL BE CONSTRUED AS EVIDENCE THAT SUCH EXAMINATION HAS BEEN MADE AND LATER CLAIMS FOR LABOR, EQUIPMENT OR MATERIALS REQUIRED BECAUSE OF DIFFICULTIES ENCOUNTERED WLL NOT BE RECOGNIZED. 2. ELECTRICAL CONTRACTOR SHALL TRACE LIGHTING AND POWER BRANCH CIRCUITS TO IDENTIFY CIRCUITS SERVING AREA WTHIN SCOPE OF WORK. PROVIDE UPDATED TYPEWRITTEN PANEL SCHEDULES AT COMPLETION OF WORK. 3. DISCONNECT ELECTRICAL SYSTEMS IN WALLS, FLOORS AND CEILINGS TO BE REMOVED. REMOVE EXISTING POWER, LIGHTING, SYSTEMS, MATERIAL AND EQUIPMENT WHICH ARE MADE OBSOLETE OR MICH INTERFERE WTH THE CONSTRUCTION OF THE PROJECT. 3.o. REINSTALL ANY SUCH POWER, LIGHTING, SYSTEMS, MATERIALS AND EQUIPMENT MICH ARE REQUIRED TO REMAIN ACTIVE FOR THE FACILITY TO BE FULLY FUNCTIONAL 4. EXISTING OUTLET BOXES AND CONDUIT MICH ARE LOCATED PROPERLY FOR NEW WORK MAY BE REUSED FOR NEW DEVICES AND WRE. 5. ALL CONDUIT AND WIRE REMOVED SHALL BE TAKEN BACK TO THE SOURCE OF SUPPLY. 6. ALL UNUSED RACEWAYS WTHIN ACCESSIBLE SPACES SHALL BE COMPLETELY REMOVED. REMOVE ALSO ASSOCIATED CONDUCTORS, JUNCTION BOXES, FASTENERS AND SUPPORTS. 7. REMOVE CONDUCTORS FROM EXISTING FLOOR BOXES BEING DEMOLISHED TO SOURCE OF SUPPLY. PATCH SURFACES AS DIRECTED BY GENERAL CONTRACTOR. 8. WHERE EXISTING EQUIPMENT OR MATERIALS ARE REMOVED OR CHANGED, ALL BRANCH CONDUITS, MICH NO LONGER ARE IN SERVICE, SHALL BE REMOVED AS DIRECTED BY THE ARCHITECT. IF, IN THE COURSE OF THE WORK, OUTLETS ARE COVERED UP OR OTHERWSE RENDERED INACCESSIBLE, ALL WRING TO SAME SHALL BE REMOVED TO THE SOURCE. IF A CIRCUIT THAT MUST REMAIN IN SERVICE IS INTERRUPTED THEREBY, IT SHALL BE RECONNECTED BY THE MOST INCONSPICUOUS MEANS SO AS TO REMAIN OPERATIONAL, NTH SAME CAPACITY AS BEFORE. ALL BUILDING SURFACES DAMAGED, AND OPENINGS LEFT BY REMOVAL OF BOXES, PIPING OR OTHER EQUIPMENT SHALL BE REPAIRED BY THE CONTRACTOR. ALL HOLES LEFT IN JUNCTION BOXES, SWTCHES, PANELS, ETC. SHALL BE CLOSED. 9. MERE NEW OPENINGS ARE CUT AND CONCEALED CONDUITS, ETC., ARE ENCOUNTERED, THEY SHALL BE REMOVED OR RELOCATED AS REQUIRED. MERE CONDUIT TO BE REMOVED STUBS THROUGH FLOORS, WALLS, AND CEILINGS, SUCH CONDUIT SHALL BE REMOVED TO THE POINT MERE THE FINISH SURFACES CAN BE PATCHED ADEQUATELY SO THAT NO EVIDENCE OF THE FORMER INSTALLATION REMAINS. 10. ALL REUSABLE DEVICES, FIXTURES AND EQUIPMENT SHALL BECOME THE PROPERTY OF THE OWNER. ALL OTHER SALVAGE AND DEBRIS SHALL BE REMOVED FROM THE PREMISES DAILY. 11. ABANDONED LOW VOLTAGE CABLES WTHIN CEILING SPACES SHALL BE REMOVED AS PER ARTICLE 725.25 OF THE NFPA-70. ELECTRICAL OUTLETS AND BOXES NOTES 1. AN OUTLET BOX OF THE APPROPRIATE SIZE AND TYPE SHALL BE PROVIDED FOR ALL LIGHTING FIXTURES, SWTCHES, RECEPTACLES, ETC. 2. ALL SWITCHES AND RECEPTACLES SHALL BE SPECIFICATION GRADE 20A MINIMUM UNLESS OTHERWSE NOTED. COORDINATE COLOR WTH ARCHITECT PRIOR TO ORDERING. 3. ALL RECEPTACLES LOCATED OUTDOOR SHALL BE WEATHER RESISTANT. COVERS SHALL BE "MILE -IN -USE" TYPE. COVER SHALL BE IDENTIFIED AND LISTED AS "EXTRA-DUT'r. 4. PROVIDE 4 11/16"x 4 11/16"x 2 1/8' SQUARE BOX AND 1" CONDUIT STUB -UP TO ACCESSIBLE CEILING FOR TELEPHONE AND DATA OUTLETS. TERMINATE CONDUITS 6" ABOVE CEILING IN ACCESSIBLE SPACE WTH 90* BEND INSULATED BUSHINGS AND PULL STRING. COORDINATE WTH TENANTS DATA/TELEPHONE CONTRACTOR FOR FURTHER ELECTRICAL AND RACEWAYS REQUIREMENTS PRIOR TO ROUGH -IN. CABLING BY OTHERS. 5. ALL JUNCTION BOX COVERS SHALL BE MARKED NTH PANEL, CIRCUIT NUMBER AND VOLTAGE WTH PERMANENT BLACK MARKER. 6. JUNCTION BOXES SHALL NOT BE MOUNTED TO THE PARTITION TOP PLATE. 7. PROVIDE ACOUSTICAL FOAM AND SEALANT AT ALL DEVICES ON DEMISING PARTITIONS. IF PARTITION IS FIRE RATED, PROVIDE FIREPROOF COMPOUND ON BACK AND SIDES OF THE BOX. 8. MERE TELEPHONE AND ELECTRICAL OUTLETS APPEAR ON PLANS AS BACK TO BACK, OUTLETS SHALL BE STAGGERED TO REDUCE NOISE TRANSMISSION. WERE WALLS AND PARTITIONS ARE REQUIRED TO HAVE A MINIMUM OF 1-HOUR FIRE -RESISTANCE RATING, BOXES SHALL BE SEPARATED BY A MINIMUM HORIZONTAL DISTANCE OF 24" INCHES OR PROTECTED NTH UL LISTED PUTTY PADS. 9. GROUNDING OF RECEPTACLES AND FIXED EQUIPMENT IN PATIENT CARE AREAS SHALL COMPLY WTH NEC ARTICLE 517,13 (A) AND (B). 10. GFC1 RECEPTACLES FOR ALL APPLIANCES MUST BE READILY ACCESSIBLE. IF RECEPTACLE CANNOT BE MADE ACCESSIBLE, PROVIDE GFCl CIRCUIT BREAKER. WIRE SIZE REOUIRED FOR BRANCH CIRCUITS AT LESS THAN 3% VOLTAGE DROP I FT TO 50 FT 51 FT m 75 FT 76 FT TO 100 FT 101 FT 70 125 FT 12SEFT TO I FT 151 FT 70 200 FT 120V 20A #12 #10 #8 #13 #6 #6 30A 110 #B #6 #6 #6 #4 40A #B #6 #6 #4 #4 #3 F50A #8 0 0 0 0 9 208V 10 20A f12 #12 #12 #10 #10 #8 30A #10 #10 #10 #8 #8 #6 40A #8 #B #B #8 #6 #6 50A #B #8 #B #6 #6 #4 60A #6 #6 #6 #6 #4 #4 70A 14 #4 #4 14 #4 #3 80A #3 #3 #3 #3 #2 #1 90A #2 #2 #2 #2 #2 #1 100A #1 #1 #1 #1 NO NO 208V 30 I 20A #12 #12 #12 #10 #10 #8 30A #10 #10 #10 #8 #8 #6 40A #8 #8 #8 #8 #6 #6 50A #8 #8 #8 #6 #6 #4 60A #6 #6 #6 #6 #6 #4 70A #4 14 14 J4 f4 #4 80A #3 #3 #3 #3 #2 #1 90A #2 #2 #2 J2 #2 #1 100A #1 0 #1 #1 #170-1 #1/01 CALCULATED USING COPPER WIRE AT 750 C. TABLE ABOVE FOR REFERENCE ASSUMING FULLY RATED CIRCUIT AT 80% OF AMPACITY. NO MORE THAN 2% VOLTAGE DROP MAXIMUM FOR FEEDERS. AS PER FBC ENERGY CONSERVATION, CHAPTER 4 ARTICLE C405.7.3.1. NO MORE THAN 3% VOLTAGE DROP MAXIMUM FOR BRANCH FEEDERS. AS PER FBC ENERGY CONSERVATION, CHAPTER 4 ARTICLE C405.7.3.2. WERE UNGROUNDED CONDUCTORS ARE INCREASED IN SIZE, EQUIPMENT GROUNDING CONDUCTORS SHALL BE INCREASED IN SIZE PROPORTIONATELY ACCORDING TO THE CIRCULAR MILL AREA OF THE UNGROUNDED CONDUCTORS. ELECTRICAL SYMBOL LEGEND (NOT ALL SYMBOLS USED ON THIS PROJECT) RECESSED LUMINAIRE EMERGENCY RECESSED LUMINAIRE. CONNECT AS 24-HOUR NIGHTLIGHT UNLESS OTHERWSE NOTED. 0 rX) LED, INCANDESCENT, COMPACT FLUORESCENT FIXTURE - CEILING MOUNTED, WALL MOUNTED I& 4P EXIT SIGN FIXTURE, SHADED QUADRANT INDICATES FACE, WTH ARROWS AS SHOWN ON PLAN - CEILING MOUNTED, WALL MOUNTED $ $2 $3 $4 H sm smp sw w 9 19 (000 IG GW ($G oc El [A RN fm we--% 121010 =P cm mmj 1-POLE, 2-POLE, 3-WAY, 4-WAY SWTCH DIMMER SWTCH, LUTRON, VERIFY LAMP TYPE (LED/INCANDESCENT/FLUORESCENT) PRIOR TO ORDER MANUAL MOTOR STARTER TOGGLE SWTCH AS NOTED; *P" INDICATES PILOT LIGHT; -WP- INDICATES WEATHERPROOF OCCUPANCY SENSORS POWER PACK DUPLEX RECEPTACLE AT 18-, ABOVE COUNTER AT 42% ISOLATED GROUND TYPE GROUND FAULT AT 42" TYPE SELF TESTING DUPLEX RECEPTACLE CEILING MOUNTED DUPLEX RECEPTACLE (2) DUPLEX RECEPTACLES IN SINGLE OUTLET BOX WTH SINGLE COVER PLATE AT 18% ABOVE COUNTER AT 42- TELEPHONE/DATA OUTLET, PROMDE 4 11/16"x 4 11/16"x 2 1/8" SQUARE BOX AND 1" CONDUIT TO ACCESSIBLE CEILING. CONFIRM WTH VENDOR PRIOR TO ROUGH -IN SPECIAL RECEPTACLE, PUSHBUTTON AS NOTED, TELEPOWER POLE FLOOR MOUNTED DUPLEX RECEPTACLE, FLOOR MOUNTED TELEPHONE/DATA OUTLET FINAL CONNECTION TO EQUIPMENT JUNCT10N BOXES, MOTOR CONNEC11ON DISCONNECT SWTCH, STARTER OR CONTACTOR, COMBINATION STARTER/DISCONNECT 120/208V PANELBOARD 277/480V PANELBOARD TELEPHONE TERMINAL BOARD ELECTRIC DOOR STRIKE/CARD READER TV OUTLET, PROVIDE 4 11/16*x 4 11/16"x 2 1/8" SQUARE BOX AND 1* CONDUIT TO ACCESSIBLE CEILING. COORDINATE MOUNTING HEIGHT PRIOR TO ROUGH -IN. BRANCH CIRCUIT CONDUIT CONCEALED ABOVE CEILING OR IN WALL, SLASH MARKS INDICATE NUMBER OF CONDUCTORS, LONGER SLASH IS NEUTRAL, (GROUND WIRE NOT SHOWN); 2 #12 - 1 #12 GROUND MINIMUM (UNLESS OTHERWSE NOTED OR MARKED); LONGER SLASH WTH HATCH MARK INDICATES ISOLATED GROUND. ISOLATED GROUND CONDUCTOR SHALL BE GREEN WTH A YELLOW STRIPE. QUANTITY OF ARROWS INDICATE QUANTITY OF HOMERUNS TO PANELBOARD. PROVIDE EQUIPMENT GROUNDING CONDUCTOR IN ALL BRANCH CIRCUITS. CIRCUITS SHARING A COMMON NEUTRAL MUST HAVE A COMMON TIE HANDLE ON THE CIRCUIT BREAKERS TO ALLOW ALL TO BE TURNED OFF SIMULTANEOUSLY. BRANCH CIRCUIT CONDUIT CONCEALED BELOW SLAB OR UNDERGROUND. CIRCUITS SHARING A COMMON NEUTRAL MUST HAVE A COMMON TIE HANDLE ON THE CIRCUIT BREAKERS TO ALLOW ALL TO BE TURNED OFF SIMULTANEOUSLY. SUBSCRIPT LEGEND E EXISTING DEVICE/UGHT AND ASSOCIATED CIRCUIT WRING TO REMAIN. PROVIDE ALL NECESSARY EXTENSION OF CONDUIT AND WRING AS REQUIRED, IN ORDER TO MAINTAIN CIRCUIT CONTINUITY TO EXISTING EQUIPMENT TO REMAIN. ERL EXISTING DEVICE/LIGHT TO BE RELOCATED. JUNCTION AND EXTEND EXISTING CONDUIT AND WRING TO NEW LOCATION AS REQUIRED. RL NEW LOCATION OF EXISTING DEVICEAIGHT. PROVIDE EXTENSION OF EXISTING CONDUIT AND WRING AS REQUIRED. (PROVIDE NEW SWTCHING AS INDICATED) R EXISTING DEVICE/LICNT TO BE REMOVED. MERE EXISTING EQUIPMENT TO REMAIN IS FED VIA EXISTING EQUIPMENT TO BE REMOVED, PROVIDE ALL NECESSARY EXTENSION OF CONDUIT AND WRING AS REQUIRED IN ORDER TO MAINTAIN CIRCUIT CONTINUITY TO EXISTING EQUIPMENT. N DEVICE/UGHT TO MATCH EXISTING BUILDING STANDARDS. f9REF9GHTERS RADIO NOTE BASE BID: CONTRACTOR SHALL PROCURE THE SERVICES OF A THIRD PARTY VENDOR TO TEST THE PUBLIC SAFETY RF RADIO COVERAGE, WTHIN THE PROJECT SCOPE OF WORK, AND DETERMINE WHETHER A NEW DAS SYSTEM IS REQUIRED PER FLORIDA FIRE PREVENTION CODE 7TH EDITION CHAPTER 11 SECTION 11.10.1 AND NFPA 72 2016 EDITION CHAPTER 24 SECTION 24.9. CONTRACTOR SHALL SUBMIT TEST REPORTS AND RECOMMENDATIONS TO THE FIRE MARSHALL AS REQUESTED BY BUILDING PERMIT COMMENTS. BID ALIERNAIE: CONTRACTOR TO PROVIDE PRICING FOR A COMPLETE IN-BULDING RF RADIO COVERAGE SYSTEM FOR THE PUBLIC SAFETY RADIO AS SET FORTH IN FLORIDA FIRE PREVENTION CODE 7TH EDITION CHAPTER 11 SECTION 11.10.1 AND NFPA 72 2016 ED11ION CHAPTER 24 SECTION 24.9 AND SHALL BE VERIFIED AS COMPLIANT PER THE CODES ABOVE AND THE AHJ. THE SYSTEM SHALL BE INSTALLED BY A TURN -KEY FIRM SPECIALIZING IN THE TRADE, TO INCLUDE NECESSARY SHOP DRAWNGS, FREQUENCY ENHANCING EQUIPMENT, INSTALLATION, TESTING, AND MONITORING TO SATISFY CODE AND AHJ REQUIREMENTS. CHANGE ORDERS FOR ADDITIONAL EQUIPMENT SHALL NOT BE PERMITTED. CONTRACTOR PROVIDING THIS PRICING SHALL BE INDEPENDENT OF THE THIRD PARTY VENDOR THAT PERFORMED THE PUBLIC SAFETY RADIO TEST AS PART OF BASE BID. MEP CONSULTING ENGINEERS SINCE 1977 FL REG NO. 3089 2016 ALDEN RD. ORLANDO, FL 32803 (407) 246-1688 WWW.PEIFLA.COM PEI PROIECT it 22121 CAMPBELL + VAN DUSEN IIARCH IT ECTU RE IIN_E�IQF DE31ro-N www.CVDstudio.com CAMPBELL + VAN DUSEN Design Studio, LLC. 255 South Orange Avenue Suite # 1240 Orlando, Florida 32801 Phone: 407.930.6016 FL. Lic. No. AA26003339 ARCHITECT OF RECORD FRANK W. CAMPBELL AIA FL LIC NO. AROO 16053 COPY OF THIS PLAN IS NOT VALID UNLESS SIGNED, SEALED AND DATED BY THE ARCHITECT OF RECORD I I 111111,f �PA)V C, S N S 4,., % op 4Z- \V z C, a 140. SAIlro-w % CC sTxTS OF 'P % PL ovkO.*6 C2 %% Bryan G. Spangler, PE, FL Reg. No. 64601 COPY OF THIS PLAN IS NOT VALID UNLESS SIGNED, SEALED AND DATED BY THE ENGINEER OF RECORD -1 LL_ (/i _j CL LLJ U < C/) LU LLJ > _j 0 CIO + L0 -'0 0e < LU LU 0 > -0 1- C) Lu '0 Lo w < 3: or-11) lcyt)l CL rL_U_4 CONSTRUCTION DOCUMENTS 03.24.2023 00 PRINCIPAL IN CHARGE F. CAMPBELL . .................................................................. PROJECT MANAGER M. TORRES .................................................................... ADVENT HEALTH WELL 65+ ZEPHYRHILLS 22-0328-01 ELECTRICAL SPECIFICATIONS El I :1::::� EXISTING ELECTRICAL PLAN E2.1 % 1 /8° = V-0° GENERAL NOTES 1. UNLESS OTHERWISE NOTED, ALL DEVICES SHOWN ON THIS PLAN SHALL BE REMOVED. 2. DEVICE QUANTITIES AND LOCATIONS SHOWN ARE APPROXIMATE. REMOVE ALL DEVICES IN WALLS BEING REMOVED AND ALL DEVICES THAT INTERFERE WITH NEW CONSTRUCTION. FIELD VERIFY. 3. REFER TO EXISTING CONDITIONS GENERAL NOTES. 4. SALVAGE CIRCUITS FOR REUSE IN RENOVATION WHEREVER PRACTICABLE. LABEL CIRCUITS THAT ARE NOT REUSED AS "SPARE". KEYED NOTES (DCONDUIT AND WIRE FOR EXISTING PARKING LOT SITE LIGHTS, BUILDING LIGHTS AND SIGNAGE HAS BEEN INSTALLED FROM LIGHTS TO NEW ELECTRIC ROOM. REFER TO RENOVATION PLAN FOR MORE INFORMATION. O2 CONDUIT WILL NEED TO BE EXTENDED TO NEW COMM ROOM. REFER TO RENOVATION PLAN FOR MORE INFORMATION. O3 CONDUIT EXISTING FUTURE SIGNAGE. CONNECT TO CIRCUIT 81-24 VIA TIMECLOCK/PHOTOCELL. REFER TO EXTERIOR LIGHTING/SIGNAGE WIRING DIAGRAM FOR MORE INFORMATION. CONNECTS TO (2) OPARKING LOT SITE LIGHTS CONNECTS TO (4)O PARKING LOT SITE LIGHTS I 4T LA CAMPBELL + VAN DUSEN 1A R,CHITECTURE IN-ER10F DEaIr3N www.CVDstudio.com CAMPBELL + VAN DUSEN Design Studio, LLC. 255 South Orange Avenue Suite # 1240 Orlando, Florida 32801 Phone: 407.930.6016 FL. Lic. No. AA26003339 ARCHITECT OF RECORD FRANK W. CAMPBELL AIA FL LIC NO. AR0016053 COPY OF THIS PLAN IS NOT VALID UNLESS SIGNED, SEALED AND DATED BY THE ARCHITECT OF RECORD ``1tillltfffj11' G SPAN 4#0 No. 64601 -a STATE OF �O F[OR1pP:' /� .. Bryan G. Spangler, PE, FL Reg. No. 64601 COPY OF THIS PLAN IS NOT VALID UNLESS SIGNED, SEALED AND DATED BY THE ENGINEER OF RECORD J U- J J Z � OLU _ a" = IV U Q LIJ w t/) J m F— � = J ILLJ � w J ,,< V 0 0U-,�'0� C. Q > 1V or12) ( CONSTRUCTION DOCUMENTS 03.24.2023 PRINCIPAL IN CHARGE F. CAMPBELL .................................................................... PROJECT MANAGER M. TORRES .................................................................... ADVENT HEALTH WELL 65+ ZEPHYRHILLS 22-0328-01 ELECTRICAL SITE 1 E3.1 LIGHTING RENOVATION PLAN 1/8" = V-0. GENERAL LIGHTNG NOTES 1. PULL UNSWITCHED HOT CONDUCTOR FROM LOCAL LIGHTING CIRCUIT TO EMERGENCY EGRESS LIGHTS. RUN 3 #12 - 1 #12 GND - 3/4-C TO INCLUDE UNSWITCHED CONDUCTOR. 2. PULL UNSWITCHED HOT CONDUCTOR FROM LOCAL LIGHTING CIRCUIT TO EXIT SIGNS. RUN 2 #12 - 1 #12 GND - 3/4-C. 3. LIGHT FIXTURES BEING REUSED SHALL BE REPAIRED, CLEANED AND RELAMPED. 4. SWITCHES SHALL BE GANGED WHEN THEY APPEAR ADJACENT TO ONE ANOTHER ON PLANS WHEREVER PRACTICABLE. PROVIDE MULTI -GANG JUNCTION BOX AND COVER PLATE AS REQUIRED. 5. DASHED ARCS INDICATE CONTINUATION OF BRANCH CIRCUIT BUT NOT SWITCH CONTROL. 6. UNLESS OTHERWISE NOTED, ALL FIXTURES AND DEVICES SHOWN ON THIS PLAN ARE NEW. ALL NEW FIXTURES AND SWITCHES SHALL MATCH EXISTING BUILDING STANDARD. 7. VERIFY THAT DIMMER MATCHES LAMP TYPE PRIOR TO ORDER. 8. ELECTRICAL CONTRACTOR SHALL PROVIDE A LUMINAIRE DISCONNECT CONNECTOR FOR ALL FLUORESCENT FIXTURES, AS REQUIRED BY N.E.C. 410.130(g)3 2011. UL LISTED CONNECTORS ARE MANUFACTURER BY IDEAL, THOMAS AND BETTS AND WAGO, ANY UL LISTED CONNECTOR WILL BE ACCEPTABLE. INSTALL PER MANUFACTURERS SPECIFICATIONS. LIGHTING PLAN NOTES FEED FIXTURES FROM EXISTING, LOCAL LIGHTING CIRCUIT. FIELD VERIFY EXACT CIRCUIT NUMBER. TYPICAL ALL EXIT SIGNS. RUN 2#12 1#12 GND - 3/4- C. PROVIDE A NEW EXTERIOR GRADE BUILDING WALL MOUNTED LED LIGHT FIXTURE - MATCH EXISTING. CONNECT ALL BUILDING MOUNTED LIGHTS TO PANEL VIA TIME CLOCK WITH PHOTOCELL. REFER TO EXTERIOR LIGHTING/SIGNAGE WIRING DIAGRAM. ---- Do �-OF rio 2 E3.1 POWER RENOVATION PLAN 1/811 = i I -oil GENERAL POWER NOTES 1. INDICATED CIRCUIT NUMBERS ARE SUGGESTED FROM EXISTING SPARE BREAKERS AND SPACES IN EXISTING PANELS. CONTRACTOR MAY USE DIFFERENT CIRCUIT NUMBERS TO MATCH FIELD CONDITIONS. 2. ELECTRICAL CONTRACTOR SHALL COORDINATE WITH INTERIOR DESIGN PACKAGE FOR ALL MILLWORK AND WALL DESIGNS PRIOR TO 3. COMMENCING WORK. EXISTING BRANCH CIRCUITS HAVE BEEN TAKEN FROM FIELD INVESTIGATION AND /OR ORIGINAL DOCUMENTS AND SHOWN FOR THE CONVENIENCE OF THE ELECTRICAL CONTRACTOR AND SHALL NOT BE CONSIDERED "AS -BUILT" CONDITION. 4. BEFORE CONSTRUCTION BEGINS, ELECTRICAL CONTRACTOR SHALL FIELD VERIFY ALL BRANCH CIRCUITS. PROVIDE TYPED, UPDATED PANEL SCHEDULES UPON COMPLETION OF WORK. 54' BACK BOX CONFIGURATION A - DIAGNOSTIC UNIT LOCATION POWER PLAN NOTES CONNECT ELECTRIC WATER HEATER. PROVIDE 30A, 3P, 240V, N-1, NON -FUSED DISCONNECT SWITCH. COORDINATE WITH PLUMBING CONTRACTOR. RUN 3#10, 1#10 GND - 3/4" C. PROVIDE FLUSH MOUNTED FLOOR BOX WITH 120V QUAD RECEPTACLE AND TELE/DATA OUTLETS, WALKER OMNIBOX SERIES (#880S2-TWO GANG) OR APPROVED EQUAL. SAWCUT FLOOR AS REQUIRED. RUN 2#12, 1#12 FOR 120V POWER. RUN 1-1/4- CONDUIT WITH PULLSTRING FOR LOW VOLTAGE CABLING. PROVIDE ALL ACCESSORIES REQUIRED FOR A COMPLETE SYSTEM. COORDINATE EXACT LOCATION, FINISHES, COVERPLATES AND TYPE OF LOW VOLTAGE OUTLETS WITH OWNER. NEW CARD READER AND ELECTRIC STRIKE. PROVIDE 3/4- RACEWAY TO ACCESSIBLE CEILING FOR LOW VOLTAGE POWER. COORDINATE WITH CARD READER VENDOR. TENANT SECURITY SYSTEM SHALL BE CONNECTED TO BUILDING FIRE ALARM SYSTEM TO RELEASE ALL LOCKS UPON ACTIVATION. PROVIDE ALL CONNEC11ONS AND ACCESSORIES REQUIRED FOR A FULLY OPERATIONAL SYSTEM. ANY CARD READERS INSTALLED IN SUCH A WAY THAT THEY PREVENT FREE EGRESS SHALL BE IN COMPLIANCE NTH SECTION 7.2.1.6.2 FOR ACCESS CONTROLLED EGRESS DOOR ASSEMBLIES (NFPA 101) PROVIDE RECESSED 2-GANG BOX AT HEIGHT SHOWN ON WELLNESS SUITE J-BOX LOCAT10N DETAIL FOR A/V CABLING. TYPICAL FOR ALL ALL WELLNESS SUITES, BROKER ROOMS AND STAFF LOUNGE. ARLINGTON MODEL #TVBS810. PROVIDE JUNC11ON BOXES AND 120V CIRCUIT FOR DOOR OPENER. COORDINATE EXACT REQUIREMENTS WITH VENDOR. PROVIDE 8'H X 4'W X 3/4-D PLYWOOD BACK BOARD ON WALL FOR TELECOMMUNICATION EQUIPMENT. PAINT NTH GRAY FIRE RETARDENT PAINT. INSTALL DOUBLE DUPLEX RECEPTACLE MOUNTED 0 42" AFF. RUN 2" E.C. TO EXISTING MAIN TELEPHONE TERMINAL BOARD. PROVIDE #6 GROUND NTH BUS BAR CONNECTED TO BUILDING GROUND LUG. --- Do CONNECT 120V POWER TO NEW EXHAUST FAN. PROVIDE MOTOR -RATED SWITCH. COORDINATE WITH MECHANICAL CONTRACTOR. FAN HAS M01ION SENSOR CONTROL. CONNECT SPLIT SYSTEM. PROVIDE 30A, 2P, 240V, N-3R FUSED DISCONNECT SWITCH ON ROOF. FUSE PER MANUFACTURER'S NAMEPLATE. COORDINATE WITH MECHANICAL CONTRACTOR. ELECTRICAL POWER IS THROUGH CONDENSING UNIT THEN TO INDOOR UNIT. RUN 2 #10 - 1 #10 GND - 3/4-C TO CONDENSING UNIT AND 2 #10 - 1 #10 GND - 3/4-C TO INDOOR UNIT. PROVIDE 30A, 2P, 240V, N-1, FUSED DISCONNECT SWITCH AT INDOOR UNI FU AS MANUFACTURER'S NAMEPLATE. '7 PROVIDE A 120V STAND ALONE DUCT MOUNTED SMOKE DETECTOR IN SUPPLY SIDE DUCTWORK OF EXISTING UNIT. PROVIDE RELAY, CONTROL MODULE, AND REMOTE TEST STATION NTH AUDIBLE AND VISUAL NOTIFICATION. CONNECTION TO EXISTING UNIT TO SHUT -DOWN UPON ACTIVATION. COORDINATE WITH MECHANICAL CONTRACTOR. PROVIDE RECESSED, FLANGELESS BOX WITH DUPLEX RECEPTACLE AT HEIGHT SHOWN ON WELLNESS SUITE J-BOX LOCATION DETAIL. ARLINGTON MODEL #TVBS810. CONNECT 120V POWER TO NEW EXHAUST FAN. PROVIDE MOTOR -RATED SWITCH. COORDINATE N CARE MEA SYMBOL LEGEND 0\,ADer,WERPOKP,CMEARAISAtE@6RyNffC IN DNT Or NEW PANELS. :ONDUIT (2)4"C. TO NEW COMM E ARE NO CRITICAL OR WET PATIENT AREAS IN THE 'E OF WORK. 2. GENERAL PATIENT CARE AREAS REQUIRE A WIRING METHOD WITH A REDUNDANT GROUND AS PER ARTICLE 517.13 OF THE NEC. GROUNDING 0 FALL RECEPTACLES, LIGHTING AND FIXED EQUIPMENT IN PATIENT CARE AREAS SHALL COMPLY WITH IV CAMPBELL + VAN DUSEN 1ARCH17ECTU RE lr�_ERIDF DE.311Z�t4 www.CVDstudio.com CAMPBELL + VAN DUSEN Design Studio, LLC. 255 South Orange Avenue Suite # 1240 Orlando, Florida 32801 Phone: 407.930.6016 FL. Lic. No. AA26003339 ARCHITECT OF RECORD FRANK W. CAMPBELL AIA FLLIC NO. AR0016053 COPY OF THIS PLAN IS NOT VALID UNLESS SIGNED, SEALED AND DATED BY THE ARCHITECT OF RECORD S PA IV, Sp No. 6460 Z STATE OF cr oe 0 %."ZORIO'?" .......... IONAt-e\ ""11111111%00 Bryan G. Spangler, PE, FL Reg. No. 64601 COPY OF THIS PLAN IS NOT VALID UNLESS SIGNED, SEALED AND DATED BY THE ENGINEER OF RECORD _j H V� ry 0 11-- LIJ r_4 C) < 0 C/') U_j LLJ > _j + Lr) _j U 7' 0.o� < LU LLj 0 > -0 It 0 LU '0 Lo Oe < 3�: Iro-0-- CL rL-U4 (1y"') CONSTRUCTION DOCUMENTS 03.24.2023 PRINCIPAL IN CHARGE F . CAMPBELL .................................................................... PROJECT MANAGER M. TORRES .......... ... I ...................................................... ADVENT HEALTH WELL 65+ ZEPHYRHILLS 22-0328-01 9. EXISTING BRANCH CIRCUITS HAVE BEEN TAKEN FROM FIELD INVESTIGATION AND/OR ORIGINAL DOCUMENTS AND SHOWN FOR THE CONVENIENCE OF THE ELECTRICAL CONTRACTOR AND SHALL NOT BE 34"' C; OF OUITLE7 BOX CONSULTING ELECTRICAL CONSIDERED "AS -BUILT" CONDITION. BEFORE F ENGINEERS CONSTRUCTION BEGINS, ELECTRICAL CONTRACTOR SINCE 1977 RENOVATION PLANS SHALL FIELD VERIFY ALL BRANCH CIRCUITS. CONFIGURATION 11 FL REG NO. 308 91 10. CONTRACTOR SHALL INCLUDE COMMISSIONING OF LCD BOX LOCATION LIGHTING CONTROL SYSTEM BY MANUFACTURER IN 2016 ALDEN RD. BASE BID. ORLANDO, FL 32803 11. VERIFY CEILING TYPES BEFORE ORDERING LIGHT WEU.W=88 StM J—WX LOCARM (407) 246-1688 FIXTURES. SCALF-- WW WWW.PEIFLA.COM Ell NOTE: 'A' PEI PROJECT t. CONFIGURATION REFERS TO Kl��D NOTE 22121 CONFIGURA11ON 'B' REFERS TO K&D NOTE CAMPBELL + VAN DUSEN ARCH IT ECTU RE IN-ERIOR DIE,31C�N www.CVDstudio.com CAMPBELL + VAN DUSEN Design Studio, LLC. 255 South Orange Avenue Suite # 1240 Orlando, Florida 32801 Phone: 407.930.6016 FL. Lic. No. AA26003339 ARCHITECT OF RECORD FRANK W. CAMPBELL AIA FL LIC NO. AR001 6053 COPY OF THIS PLAN IS NOT VALID UNLESS SIGNED, SEALED AND DATED BY THE ARCHITECT OF RECORD % SP XA G EN % *. No. 64601 S TATE OF j, 1.6 4OR10' ,ftz/ONAL S%N %% Bryan G. Spangler, PE, FL Reg. No. 64601 COPY OF THIS PLAN IS NOT VALID UNLESS SIGNED, SEALED AND DATED BY THE ENGINEER OF RECORD _j LL_ (lei 0 CL LU ci Uj UJI > __j + U LU ELECTRICAL RENOVATION PLAN ROOF "o < LU o > 1-011 1/8" w a- C) LU 3: '0 Lo or. 01� < ru--4j GENERAL NOTES: 1 . REFER TO RISER DIAGRAM, ELECTRICAL DETAILS AND PANEL SCHEDULES FOR MORE INFORMATION. 2. PROVIDE NEW NAME ENGRAVED COVER PLATES INDICATING SUPPLY PANEL AND CIRCUIT NUMBER(S) FOR ALL ELECTRICAL DEVICES IN THIS PROJECT. ENGRAVING SHALL BE RED FOR CRITICAL AND BLACK FOR NORMAL CIRCUITS. 3. PROVIDE NEW UPDATED TYPED PANEL SCHEDULES FOR ALL PANELS USED IN THIS PROJECT. VERIFY EXACT PANEL IDENTIFICATION NTH OWNER. PROVIDE NEW NAME ENGRAVED PLATES FOR ALL PANELS NOT IDENTIFIED PROPERLY. VERIFY PRIOR TO ORDERING. 4. PROVIDE PHENOLIC NAMEPLATES ON ALL PANELBOARDS, SWITCHBOARDS, DISCONNECTS, TRANSFORMERS, ETC, INDICATING DESIGNATION, CIRCUIT NUMBER(S), VOLTAGE AND WHERE UNIT IS FED FROM. SECURE NAMEPLATES WITH AT LEAST TWO SCREWS OR RIVErS. CEMENTING AND ADHESIVE INSTALLATION WILL NOT BE ACCEPTABLE. NAMEPLATES SHALL BE COLORED AS PER SPECIFICATIONS. 5. SCREENED DEVICES ARE EXISTING TO REMAIN DEVICES AND ARE SHOWN FOR REFERENCE ONLY. 6. EXISTING BRANCH CIRCUITS HAVE BEEN TAKEN FROM FIELD INVES71GATION AND /OR ORIGINAL DOCUMENTS AND SHOWN FOR THE CONVENIENCE OF THE ELECTRICAL CONTRACTOR AND SHALL NOT BE CONSIDERED *AS-BUIL'r CONDITION. BEFORE CONSTRUCTION BEGINS, ELECTRICAL CONTRACTOR SHALL FIELD VERIFY ALL BRANCH CIRCUITS. RENOVA110N PLAN NOTES PROVIDE A NEW 60A, N-311 ENCLOSURE, 24OV, 30 HEAVY DUTY FUSED DISCONNECT SWITCH. PROVIDE THREE (3) NEW RK5 FUSES SIZED PER MANUFACTURERS NAMEPLATE. INFORMATION SHOWN WAS PROVIDED AT TIME OF DESIGN BY DIVISION 15, MCA 39AMPS, MFS 45AMP. COORDINATE WITH DIVISION 15 DRAWINGS, DETAILS, EQUIPMENT LIST AND SPECIFICATIONS PRIOR TO ORDERING. 344,146G. - 1-1/4-C. PROVIDE ANEW WEATHER -RESISTANT LISTED GFCI RECEPTACLE. PROVIDE A WEATHERPROOF IN -USE COVER. CONNECT PER MANUFACTURERS SPECIFICATIONS. PROVIDE A NEW 30A, N-3R ENCLOSURE, 24OV, 30 HEAVY DUTY FUSED DISCONNECT SWITCH. PROVIDE THREE (3) NEW FUSES SIZED PER MANUFACTURERS NAMEPLATE. INFORMATION SHOWN WAS PROVIDED AT TIME OF DESIGN BY DIVISION 23, MCA 18AMPS, MFS 30AMPS. COORDINATE WITH DIVISION 23 DRAWINGS, DETAILS, EQUIPMENT LIST AND SPECIFICATIONS PRIOR TO ORDERING. 3410, 141OGND. - 3/4"C. PROVIDE A 120V STAND ALONE DUCT MOUNTED SMOKE DETECTOR IN SUPPLY SIDE DUCTWORK OF EXISTING UNIT. PROVIDE RELAY, CONTROL MODULE, AND REMOTE TEST STATION WITH AUDIBLE AND VISUAL NOTIFICATION. CONNECTION TO EXISTING UNIT TO SHUT -DOWN UPON ACTIVATION. COORDINATE WITH MECHANICAL CONTRACTOR. CONSTRUCTION DOCUMENTS 03.24.2023 PRINCIPAL IN CHARGE F. CAMPBELL .................................................................... PROJECT MANAGER M. TORRES .................................................................... ADVENT HEALTH WELL 65+ ZEPHYRHILLS 22-0328-01 MEP CONSULTING ELECTRICAL ENGINEERS SINCE 1977 DEMOLITION PLAN - FIL REG NO. 3089 ROOF 2016 ALDEN RD. ORLANDO, FL 1 32803 (407) 246-1688 WWW.PEIFLA.COM E392 PEI PROJECT f 22121 NEW PANEL I PANELBOARD SCHEDULE: MDP BOLT -ON 0 NEW 0 SINGLE PANEL 0 NORMAL N PLUG-IN 0 EXISTING 0 DOUBLE PANEL 0 CRITICAL 0 VOLTS: 120/208 3 0 4 WIRE PANEL RATED 0 800 AMPS: M.C.B: 0 INDOOR N SURFACE N LIFE SAFETY 0 TYPE: SQ-D HCM NEMA 1 kAIC 65 PANEL OVERLOAD 800 AMPS: PROTEC11ON M.LO: 0 OUTDOOR 0 RECESSED 0 EQUIPMENT 0 FED FROM: UTILITY MAIN DISC. LOCATION: AS SHOWN N 9 E LOAD (AMPS IDEN11FICATION ) AO BO Co C. B. AMP w _1 0 a_ CKT. NO. CKT. NO. w_j ao C.B. LOA AMP AO IDEN71FICATION N F PANEL Al 82 200 3 1 2 3 200 73.6 PANEL 81 7 - - 3 4 - - 75, 5 6 SPACE 7 8 2 30 13 CU-1 9 10 - - 13 ----- 11 1 12 20 -- ----- RTU-2 32 35 3 13 14 1 20 ----- ----- 32 - 15 16 1 20 ----- 32 - - 17 18 1 20 -- ----- RTU-3 45 3 19 1 20 1 20 ----- 9 - - 21 122 1 ----- 39 - - 23 24 1 -- ----- RTU-4 35 3 25 26 1 1 20 ----- 2 - - 27 28 1 20 - - 1 29 30 1 20 -- ----- RTU-5 39 45 3 31 32 1 20 ----- - - 33 341 1 20 ----- ---- 39 - - 35 36 1 _20 -- ----- 1 SPD 37 38 1 20 ----- 39 41 .42 40 1 1 20 ----- 20 - ----- ------ -- SUBTOTAL AMPS 122412141 211 86. 88.7 62.5 SUBTOTAL AMPS TOTAL AMPS "A" PHASE: 310.6 MAXIMUM CONNECTION PHASE AMPS: 310.6 TOTAL AMPS "B" PHASE: 302.7 TOTAL CONNECTED kVA: 111.8 TOTAL AMPS "C" PHASE: 273.5 TOTAL DEMAND kVA/AMPS: 111.8/310.6 NOTES: 1. PROVIDE A NEW SPD - PQ PROTECTION #PQCF-160-120/208-3Y. CONNECT PER MANUFACTURERS SPECIFICATIONS. 2. 3. 4. PROVIDE A NEW UPDATED TYPED PANEL SCHEDULE. NEW PANEL I PANEII )ARD SCHEDULE: Al BOLT -ON M NEW E SINGLE PANEL N NORMAL 0 1 PLUG-IN 0 EXISTING 0 DOUBLE PANEL 0 CRITICAL 0 VOLTS: 120/208 3 0 4 WIRE PANEL RATED 0 225 AMPS: M.C.B: 0 INDOOR 0 SURFACE 0 LIFE SAFETY 0 TYPE: SQ-D NQOD NEMA 1 kAIC 42 PANEL OVERLOAD 200 AMPS: PROTECTION M-LO: 0 OUTDOOR 0 RECESSED 0 EQUIPMENT 0 FED FROM: MDP LOCATION: AS SHOWN N ? E LOAD (AMPS) IDEN71FICATION AO Co C.B. AMP w_j COL CKT. NO. CKT. NO. I w_j 0 I CL C.B. LOA AMP AO I IDENTIFICATION N 0 T E RECEPTS. - WELLNESS SUITE 4 9 20 1 1 2 1 20 6 RECEPTS. - CONSULT/BROKER/TLT RECEPTS. - WELLNESS SUITE 3 20 1 3 4 1 1 20 RECEPTS. - BREAKROOM FRIDGE RECEPTS. - WELLNESS SUITE 2 9 20 1 5 6 1 20 RECEPTS. - BREAKROOM FRIDGE IRECEPTS. - WELLNESS SUITE 1 9 20 1 1 7 8 1 1 20 8 RECEPTS. - BREAKROOM MICRO RECEPTS. - COMMUNITY 20 1 9 10 1 20 3 RECEPTS. - BREAKROOM COUNTER RECEPTS. - COMMUNITY COUI 20 1 11 12 1 1 20 RECEPTS. - BREAKROOM COUNTER RECEPTS. - EWC, TOILETS 103,105 1 4.5 20 1 13 14 1 20 7.5 RECEPTS. - BREAKROOM, TLT IRECEPTS. - LOBBY RECEPTIOI 20 1 1 15 16 1 20 3 RECEPTS. - AUTOCLAVE AUTO -DOOR - LOBBY 20 1 17 18 1 20 3 RECEPTS. - AUTOCLAVE RECEPTS. - LOBBY 1 6 20 1 19 20 1 1 20 3 RECEPT. - COMM ROOM J RECEPTS. - HUDDLE 20 1 21 22 1 20 3 RECEPT. - COMM ROOM IRECEPTS. - HUDDLE 20 1 1 23 24 1 20 RECEPT. - COMM ROOM RECEPTS. - HUDDLE 9 20 1 25 26 1 20 3 RECEPT. - COMMROOM RECEPTS. - HUDDLE 9 20 1 27 28 1 1 20 RECEPT. - COMM ROOM RECEPTS. - HUDDLE 20 1 29 30 1 20 RECEPT. - COMM ROOM 20 RECEPT. - MED ROOM FRIDGE IIRECEPTS. - MED ROOM/STRGE 9 20 1 31 32 1 RECEPTS. - LAB - FRIDGE 8 20 1 33 1 34 1 20 RECEPT. - MED ROOM FRIDGE RECEPTS. - LAB 9 20 1 35 36 1 20 -- ----- 20 1 37 38 1 20 ---- 20 1 39 40 20 1 41 42 ----- SUBTOTAL AMPS 146.51 44 1 49 .5 28 20 1 SU13TOTAL AMPS TOTAL AMPS "A" PHASE: 82 MAXIMUM CONNECTION PHASE AMPS: 82 TOTAL AMPS "B" PHASE: 72 TOTAL CONNECTED kVA: 29.5 TOTAL AMPS "C" PHASE: 69 TOTAL DEMAND kVA/AMPS: 29.5/82 NOTES: 1. 2. 3. 4. PROVIDE A NEW UPDATED TYPED PANEL SCHEDULE. NEW PANEL I BOLT -ON E NEW E SINGLE PANEL 0 NORMALE PANELBOARD SCHEDULE: BI PLUG-IN 0 EXISTING 0 DOUBLE PANEL 0 CRITICAL 0 VOLTS: 1208/208 3 0 4 WIRE PANEL RATED 0 225 AMPS: M.C.B: 0 INDOOR E SURFACE 0 LIFE SAFETY 0 TYPE: SQ-D NQOD NEMAl kAIC 42 PANELOVERLOAD 200 AMPS: PROTECTION M.LO: 0 OUTDOOR 0 RECESSED 0 EQUIPMENT 0 FED FROM:- MDP LOCATION: AS SHOWN N ? LOA IDENTIFICATION C.B. AO AMP W-1 0 a_ CKT. NO. CKT. NO. W_j 00 C.B. LOA IDENTIFICATION AMP AO :N ? 4.5KW WATER HEATER 221.6 30 2 1 2 1 20 12.5 LTG.-CONSULT/WELLNESS SUITES 1-48 - - 3 4 1 20 7.8 LTG.-LOBBYTLTS.,COMMUNITY RECIRC PUMP 3 20 1 5 6 1 20 LTG.-CONSIJLTCOMM,J.C.,STRGE, MFQRM HUDDI F RECEPT. - WORK ROOM 6 20 1 7 8 1 20 7.5 LTG.-BREAK,TLT.,AUTOCLAVE,WORKRM., PRACTICE, r.ARF_ CORRIDOR 126 IRECEPT. - PRACTICE/ADMIN 7.5 20 1 9 10 1 20 9. LTG. - CORRIDORS 122, 123 RECEPT. - CARE COORD. 9 20 1 11 12 1 20 LTG. - CORRIDORS 124, 125 RECEPT. - CONSULT/ELEC. 6 20 1 13 14 1 20 1 EF-2,3,6,7 RECEPTS. - WELLNESS SUITE 8 9 20 1 15 16 1 20 1 EF-1,4,5 IRECEPTS. - WELLNESS SUITE 7 9 20 1 17 18 1 20 7.5 ROOFTOP RECEPTACLES RECEPTS. - WELLNESS SUITE 6 9 20 1 1 19 20 1 20 4 TIMECLOCK/EXTERIOR BUILDING LIGHTS RECEPTS. - WELLNESS SUITE 5 9 20 t 1 21 1 22 1 1 20 4 SITE LIGHTS RECEPTS. - CORRIDOR 125 20 1 23 24 1 20 3 SIGNAGE IRECEPTS. - CORRIDOR 124 6 20 1 25 26 1 20 ----- RECEPTS. - HUDDLE PRINTER 6 20 1 27 28 1 20 RECEPTS. - HUDDLE PRINTER 6 20 1 29 30 1 20 -- ----- 20 1 31 32 1 20 20 1 33 34 1 20 20 1 135 20 1 1,371,38 1 120 -- ----- 20 1 39 40 1 20 ------ 20 1 41 42 20 -- ----- SUBTOTAL AMPS 148.6153.11 25 122.6129.5 SUBTOTAL AMPS TOTAL AMPS "A" PHASE: 73.6 MAXIMUM CONNECTION PHASE AMPS: 75.7 TOTAL AMPS "B" PHASE: 75.7 TOTAL CONNECTED kVA: 27.2 TOTAL AMPS "C" PHASE: 62.5 TOTAL DEMAND kVA/AMPS: 27.2/75.7 NOTES: 1. 2. 3. 4. PROVIDE A NEW UPDATED TYPED PANEL SCHEDULE. CAMPBELL + VAN DUSEN IARCH IT ECTU RE It-4-ERIOR DE-3113N www.CVDstudio.com CAMPBELL + VAN DUSEN Design Studio, LLC. 255 South Orange Avenue Suite # 1240 Orlando, Florida 32801 Phone: 407.930.6016 FL. Lic. No. AA26003339 ARCHITECT OF RECORD FRANK W. CAMPBELL AIA FLLIC NO. AR0016053 COPY OF THIS PLAN IS NOT VALID UNLESS SIGNED, SEALED AND DATED BY THE ARCHITECT OF RECORD ,,,-* %%%% %%I I I I i I j I,lf/ /-' GL SPA k Jl# 4�pE % . No. 601 64 STATE OF X Z .141 0 % -4`�ZORIO�' 'c� �T/ON At. VNI %% I11111111101,0% f I Bryan G. Spangler, PE, FL Reg. No. 64601 COPY OF THIS PLAN IS NOT VALID UNLESS SIGNED, SEALED AND DATED BY THE ENGINEER OF RECORD 0 CL _T_ IL LLJ w U < 0 C/) LU LU > _j 7- co Lr) �'o Cie < LU L.0 >-0 0 0 Uj CL- It '0 L-0 w a- < 3: PL-U4 or-0, ((Yy)) CONSTRUCTION DOCUMENTS 03.24.2023 PRINCIPAL IN CHARGE F. CAMPBELL .................................................................... PROJECT MANAGER M. TORRES .................................................................... ADVENT HEALTH WELL 65+ ZEPHYRHILLS 22-0328-01 MEP CONSULTING PANEL MGINEERS SINCE 1977 SCHEDULES FL REG NO. 3089 2016 ALDEN RD. ORLANDO, FL 32803 (407) 246-1688 WWW.PE)FLA.COM E4e I PEI PROJECT it 22121 GRADE 2 SETS OF 44600MCM CU IN 4* CONDUIT EACH SET — F— — — — — — — — — - 7, -11 EXISTING CT CABINET EXISTING UTILITY METER L UTILITY ITRANSFORMERI I 1201208V, 30,4W I 1 SECONDARY 1 L-------------- V ----------- i 2 SETS OF 44600MCM CU IN 41 CONDUIT EACH SET EXISTING MAIN 1 OF I 800A 11201208V,30,4W AIG-42KA L -i 143/0 CU GROUND F- 0 to- o o o EXISTING GROUND BAR I _�EV� CM PIPING STRUCTURALSTEEL 1 F- 7 TWO 10'LONG 5/8'0 CU. CLAD GROUND RODS EXISTlNG POWER RISER DIAGMM SCALE: NONE NOTE: RISER IS SHOWN FOR REFERENCE ONLY. ALL DEVICES ARE EXISTING TO REMAIN NEW MDP 2 SETS OF 44600MCM CU, 14310 CU GND IN 4' CONDUIT EACH SET UTILIZE EXISTING CONDUIT AND EXTEND TO NEW PANEL GENERAL NOTES: 1 REFER TO PANEL SCHEDULES, EQUIPMENT SCHEDULES/DETAILS/PARTIAL RISER DIAGRAM FOR MORE INFORMATION. 2. RISER DIAGRAM IS DIAGRAMMATIC AND INTENDS TO SHOW THE REQUIRED CONNECTIONS. FIELD COORDINATE EXACT CONDUIT ROUTING AND EQUIPMENT LAYOUT PRIOR TO ROUGH IN. ALL NEW WORK IN THIS PROJECT MAY NOT BE SHOWN ON THIS SHEET. REFER TO RENOVATION PLANS FOR ADDITIONAL WORK. 3. COORDINATE ALL DEVICE LOCATIONS WITH MECHANICAL DRAWINGS AND DIAGRAMS PRIOR TO ROUGH IN. NEW PANEL Al (200A) NEW PANEL B1 (200A) 4. PROVIDE NEW NAME ENGRAVED COVER PLATES INDICATING SUPPLY PANEL AND CIRCUIT NUMBER(S) FOR ALL ELECTRICAL DEVICES IN THIS PROJECT. ENGRAVING SHALL BE RED FOR CRITICAL AND BLACK FOR NORMAL CIRCUITS. 443/0, 1 -#4GND. - 2-1/2-C. 5. PROVIDE NEW UPDATED TYPED PANEL SCHEDULES FOR ALL PANELS USED IN THIS PROJECT. VERIFY EXACT PANEL IDENTIFICATION WITH OWNER. PROVIDE NEW NAME ENGRAVED PLATES FOR ALL PANELS NOT IDENTIFIED PROPERLY. VERIFY PRIOR TO ORDERING. 6. PROVIDE PHENOLIC NAMEPLATES ON ALL PANELBOARDS, SWITCHBOARDS, DISCONNECTS, TRANSFORMERS, ELECTRIC DOORS, ETC, INDICATING DESIGNATION, CIRCUIT NUMBER(S), VOLTAGE AND WHERE UNIT IS FED FROM. SECURE NAMEPLATES WITH AT LEAST TWO SCREWS/RIVETS OR APPROVED CEMENTIADHESIVE. NAMEPLATES SHALL BE COLORED AS PER SPECIFICATIONS. 7. PROVIDE CABLE REDUCERS AS REQUIRED TO COORDINATE OVERSIZED PHASEINEUTRAUGROUND CONDUCTORS NTH TERMINATION LUG SIZE OR PROVIDE TERMINATION LUGS SIZED FOR FEEDERS. 8. NO SERIES RATING FAULT CURRENT ALLOWED. 9. ALL WIRE/CONDUCTORS SHOWN ON RISER ARE COPPER CONDUCTORS UNLESS NOTED OTHERWISE. KEYED NOTES: 0 REFER TO PANEL SCHEDULES FOR MORE INFORMATION. CAMPBELL + VAN DUSEN 14 RC H 11 FC TH ? F I'-%17=Rlr.R T)F:d1vN1 www.CVDstudio.com CAMPBELL + VAN DUSEN Design Studio, LLC. 255 South Orange Avenue Suite # 1240 Orlando, Florida 32801 Phone: 407.930.6016 FL. Lic. No. AA26003339 ARCHITECT OF RECORD FRANK W. CAMPBELL AIA FL LIC NO. AROO 16053 COPY OF THIS PLAN IS NOT VALID UNLESS SIGNED, SEALED AND DATED BY THE ARCHITECT OF RECORD SPAeV 0 .�\cIENs'- 4$' % -P 64601 STATE OF L9 /ONAL Bryan G. Spangler, PE, FL Reg. No. 64601 COPY OF THIS PLAN IS NOT VALID UNLESS SIGNED, SEALED AND DATED BY THE ENGINEER OF RECORD __j LL- 0 2= r) LU UC/) LU LU > __j C) -T— 11-- F— + LO U -7 < LU LU > T- (.) 0 0 LU CL- -0 'o L'r) w < 3�: or-01 a- rL1-U4 (1yr)) CONSTRUCTION DOCUMENTS 03.24.2023 *0 PRINCIPAL IN CHARGE F. CAMPBELL . .............................................. I ................... PROJECT MANAGER M. TORRES .................................................................... ADVENT HEALTH WELL 65+ ZEPHYRHILLS 22-0328-01 DIAGRAM '01M kL CAMPBELL +VAN DU EN xRCHI1F4- T€I s F i,-JT::R1C'R DF_ l.';h www.CVDstudio.com CAMPBELL + VAN DUSEN Design Studio, LLC. 255 South Orange Avenue Suite # 1240 Orlando, Florida 32801 Phone: 407.930.6016 FL. Lic. No. AA26003339 ARCHITECT OF RECORD FRANK W. CAMPBELL AIA FL LIC NO. AR0016053 COPY OF THIS PLAN IS NOT VALID UNLESS SIGNED. SEALED AND DATED BY THE ARCHITECT OF RECORD \G PV • No. C-4601 STATE OF L v/ Bryan G. Spangler, P , FL Reg. No. 64601 COPY OF THIS PLAN IS NOT VALID UNLESS SIGNED, SEALED AND DATED BY THE ENGINEER OF RECORD J U- J J Z � O _ r = LU Iry �- IV U J Q > v> Lc I LL1 J J Q = J m F- F- L = J �10_ ry Q Lij LU � O 'O cr p w Q > orll�) IZ N c`7 CONSTRUCTION DOCUMENTS 03.24.2023 PRINCIPAL IN CHARGE F. CAMPBELL .................................................................... PROJECT MANAGER M. TORRES .................................................................... ADVENT HEALTH WELL 65+ ZEPHYRHILLS 22-0328-01 MEP CONSULTING SCHEDULES ENGINEERS SINCE 1977 AND DETAILS 1 REG NO. 3089 2016 ALDEN RD. ORLANDO, FL 32803 (407) 246-1688 WWW.PEIFLA.COM E5o2 PEI PROJECT 22121 SHUT-OFF BALL VALVES (TYP.)- UNION (TYP.) PIPE TEMPERATURE AND PRESSURE RELIEF VALVE TO MOP SINK �L --- L TEMPERATURE GAUGE EWH-1 (365 LBS.) HOT WATER SUPPLY BALL VALVE (TYP.) /-CHECK VALVE (TYP.) COLD WATER SUPPLY WATTS DET-12 POTABLE WATER THERMAL EXPANSION TANK W/ WATTS SERVICE CHECK VALVE - 3/4- WATER HEATER STRAPS ANCHORED TO WALL FRAMING (TYPICAL OF 2) - DRAIN VALVE 24 GAUGE GALVANIZED STEEL OR 60 MIL HIGH IMPACT PLASTIC DRAIN PAN. WALL SHELF TO SUPPORT WATER HEATER WEIGHT. (PROVIDED AND INSTALLED BY PLUMBING CONTRACTOR) TERMINATE 3/4* TEMP. & PRESS. AND 1* DRAIN PAN PIPING ABOVE MOP SINK MOP SINK FLOOR LINE WATER HEATER SPECIFICATI WATER HEATER SHALL BE RHEEM MODEL NO. EGSP30 WITH 30 GALLON STORAGE CAPACITY, RATED FOR 4.5 KIN, 208 VOLTS, 1 PHASE (10). WATER HEATER OPERATING WEIGHT = 365 LBS WATER HEATER SHELF SHALL BE PROVIDED AND INSTALLED BY PLUMBING CONTRACTOR. ELECTRIC WATER HEATER DETAIL (EVM-1) SCALE: N.T.S. UNIVERSAL TOP/BOTTOM BEAM CLAMP EQUAL TO B-LINE TYPE 19-SP69 3/8-0 MIN. HANGER ROD COUPLING ADJUSTABLE CLEVIS HANGER EQUAL TO B-LINE TYPE 10-SP-69 NW Nultb: 1. SIZE HANGER AND CLAMP TO ADEQUATELY SUPPORT LOAD (REFER TO B-LINE HANGER CATALOG). 2. FOR COPPER TUBING USE COPPER PLATED OR PAINTED B317OCT, FELT LINED B3170F, OR PLASTIC COATED HANGERS. PIPE SUPPORT DETAIL NOT TO SCALE Hk`m r%^r% HEAVY 0 CLEVIS h VAPOR BAR INSULA11ON 16 GA. G METAL Sj MIN. 12" 'KING 'PORT NUT CLEVIS HANGER DETAIL NOT TO SCALE ICE MAKER WALL BOX GUY GRAY No. BIM875 WATER HAMMER ARRESTOR, SIOUX CHIEF, MA -A, TYP7- PROVIDE MINIMUM 6FT. COILED TUBING FOR CONNECTION TO (OTHER PROVIDED) REFRIGERATOR ICE -MAKER, SHUT-OFF VALVE (TYPICAL) �,A WHITE ENAMEL, STEEL SUPPLY 48m TO 60" AND DRAIN BOX WITH TO FLOOR SHUT-OFF VALVES AND WATER HAMMER ARRESTORS 1/2"CW AT CONTRACTOR'S OPTION TOP SUPPLY MODEL ACCEPTABLE, WATER HAMMER ARRESTORS TO BE INSTALLED IN VERTICAL POSITION WHENEVER POSSIBLE BUT IN NO CASE LESS THAN 90' SUPPLY TUBING MAY BE COPPER OR FOOD GRADE PLASTIC TUBING. ICE MAKER SUPPLY BO -1) DETAIL NOT TO SCALE SIMILAR TO ZURN MODEL#Z-1400-KC TEMPERATURE GAUGE PRESSURE GAUGE (TYP.) IN -LINE CIRCULATING PUMP AQUASTAT WIRED BY DIV. 16 FULL PORT BALL VALVE (TYP.) HOT WATER RETURN FULL SIZE BY-PASS LOOP HOT WATER RETURN CIRCULATING PUMP GRUNDFOS MODEL ALPHA2 15-55SF NTH 3 SETTINGS AND LED DISPLAY. PHASE: 1 VOLTS: 115 POWER INPUT. 5-45 W HZ: 60 PSI: 145.04 LIQUID TEMP RANGE: 35.6-230T SELECTED LIQUID TEMP: 1407 FLOW. 2 GPM LIGHT DUTY TOP COVER (GAS & WATERTIGHT) FINISHED FLOOR 7 "-'��INSIDE CAULK `*�FITTING OR EXTENSION TO SOIL OR WASTE AS REQUIRED FLOOR CLEANOUT (FCO) DETAIL NOT TO SCALE CLE PLU SOIL 0 WASTE ROUND SECURED ALUMINUM COVER SIMILAR TO ZURN MODEL # Z-1469 WALL WALL CLEANOUIT (WCO) DETAIL NOT TO SCALE PLUMBING FIXTURE SCHEDULE PLAN DESCRIPTION MANUF. / MODEL No. MARK SINK: (SINGLE COMPARTMENT)(UNDERMOUNT)(ADA COMPLIANT) 1. 18 GAUGE STAINLESS STEEL 25mx22*x6" SINGLE BOWL, ELKAY REAR CENTER DRAIN, UNDERMOUNT FINISH: POLISHED SATIN ECTSRAD25226TBG 2. FITTING: 5-1/4m RIGID/SWING GOOSENECK SPOUT, DECK MOUNTED CHICAGO FAUCET FAUCET WITH B-CENTER, 1.5 GPM, 4-WRISTBLADE NTH 786-GN2AFCE1ABCP COLOR -CODED INDEX, FINISH: CHROME 3. TRAP: CAST BODY ADJUSTABLE "P* TRAP WITH CLEANOUT. McGUIRE 4. SUPPLY. 1/2- THREEWAY ANGLE BALL STOP, 1/4 TURN, NTH ANNEALED VERTICAL TUBE AND ESCUTCHEON. McGUIRE S-2 SINK: (SINGLE COMPARTMENT)(UNDERMOUNT)(ADA COMPLIANT) 1. 18 GAUGE STAINLESS STEEL 16-1/2*x20-1/2*x5-3/8* ELKAY SINGLE BOWL, REAR CENTER DRAIN, UNDERMOUNT, FINISH: EWHAD141855PD LUSTROUS SATIN 2. FITTING: 5-1/4- RIGID/SWING GOOSENECK SPOUT, DECK MOUNTED CHICAGO FAUCET FAUCET WITH B-CENTER, 1.5 GPM, 4-WRISTBLADE NTH 786-GN2AFCE1 ABCP COLOR -CODED INDEX, FINISH: CHROME 3. TRAP: CAST BODY ADJUSTABLE *P" TRAP NTH CLEANOUT. McGUIRE 4. SUPPLY: 1/2- THREEWAY ANGLE BALL STOP, 1/4 TURN, WITH McGUIRE ANNEALED VERTICAL TUBE AND ESCUTCHEON. S-3 SINK: (BUILT IN) 1. SINK IS BUILT-IN TO COUNTERTOP PROVIDED BY MIDMARK 2. FITTING: 4* CENTERSET FAUCET, WRIST BLADE HANDLES, 360* MAINUNE SWIVEL SPOUT, 1.0 GPM, WATER SAVING AERATOR XD645EG-CP TRAP: CAST BODY ADJUSTABLE *P" TRAP WITH CLEANOUT. McGUIRE 4. SUPPLY. 3/8m ANGLE SUPPLY WITH PLASTIC VERTICAL TUBE, McGUIRE WHEEL HANDLE STOPS AND ESCUTCHEON. S-4 SINK: 1. SINK AND FAUCET ARE PROMDED BY MIDMARK 2. TRAP: CAST BODY ADJUSTABLE "P" TRAP WITH CLEANOUT. McGUIRE 3. SUPPLY. 3/8- ANGLE SUPPLY WITH PLASTIC VERTICAL TUBE, McGUIRE I NAEL HANDLE STOPS AND ESCUTCHEON. WC-1 WATER CLOSET: (ADA COMPLIANT) 1. ELONGATED BOWL, VITREOUS CHINA, 1.6 GPF: FINISH WHITE KOHLER K-3493-0 ICONTRACTOR SHALL COORDINATE TANK WITH LEVER RIGHT/LEFT LOCATION PER APPROACH PER RESTROOM LAYOUT 2. SEAT: STRONGHOLD ELONGATED OPEN -FRONT TOILET SEAT WITH KOHLER QUIET CLOSE, INTEGRATED HANDLE AND CHECK HINGE K-4731-GC-0 FINISH: WAITE 3. SUPPLY. 3/8" ANGLE BALL STOP, 1/4 TURN, WITH ANNEALED McGUIRE VERTICAL TUBE AND ESCUTCHEON. L-1 LAVATORY. (UNDERMOUNT)(ADA COMPLAINT) 1. 20-1/2" RECTANGULAR UNDERMOUNT SINK, FINISH:WHITE KOHLER K-20000 2. FITTING: TWO HANDLE WIDESPREAD RIGID/SWIVEL GOOSENECK AMERICAN STANDARD SPOUT WITH r REACH, 0.5 GPM, FINISH: CHROME 6540.277 3. TRAP: CAST BODY ADJUSTABLE "P' TRAP WITH CLEANOUT McGUIRE AND WHEELCHAIR DRAIN OFFSET. INSULATE OFFSET, DRAIN AND HOT WATER SUPPLY. 4. SUPPLY: 3/8" ANGLE SUPPLY NTH ANNEALED VERTICAL TUBE, McGUIRE WHEEL HANDLE STOPS AND ESCUTCHEON. MS-1 MOP SINK: 1. 24*x24" MOP SERVICE BASIN NTH INTEGRAL MOLDED DRAIN, PROFLO 10" DEEP PFMB2424 2. FITTING: TWO HANDLE WALL MOUNTED SERVICE SINK FAUCET. PROFLO PF1119 - 24"x24" WALL GUARD, 24"x12" STAINLESS STEEL PANELS PROFLO PRMB2424 EWC-1 ELECTRIC WATER COOLER: (BI-LEVEL)(BOTTLE FILLER)(ADA COMPLIANT) 1. WALL MOUNTED ELECTRIC WATER COOLER, EZH20 BOTTLE ELKAY FILLING STATION AND VERSATILE BI-LEVEL ADA COOLER, HIGH LZSTLG2WSSK EFFICIENCY FILTERED REFRIGERATED STAINLESS. HANDS FREE, VISUAL FILTER MONITOR AND ANTIMICROBIAL 8.0 GPH FINISH: STAINLESS STEEL 2. TRAP: CAST BODY ADJUSTABLE "P" TRAP WITH CLEANOUT. McGUIRE 3. SUPPLY- 3/8" ANGLE BALL STOP, 1/4 TURN, WITH ANNEALED McGUIRE VERTICAL TUBE AND ESCUTCHEON. 4. ELECTRICAL- MOTOR COMPRESSOR HERMETICALLY SEALED RECIPROCATING TYPE, 115 VOLT, 6 AMP 5. CARRIER: RECTANGULAR STEEL UPRIGHTS. ZURN Z-1200 SERIES FD-1 FLOOR DRAIN (AUTOMATIC TRAP PRIMER): 1. DRAIN: CAST IRON BODY WITH BOTTOM OUTLET ZURN COMBINATION INVERTIBLE MEMBRANE CLAMP AND DEEP ZN-415-P SEAL TRAP ADJUSTABLE TYPE NICKEL CAST BRONZE STRAINER, TRAP PRIMER CONNECTION. 2. SANI-GUARD AUTOMATIC TRAP PRIMER, ALL BRONZE BODY ZURN NTH INTEGRAL VACUUM BREAKER, NON -LIMING INTERNAL Z-1022 OPERATING ASSEMBLY NTH GASKETED BRONZE COVER. CONTRACTOR SHALL COORDINATE AND VERIFY WITH OWNER AND ARCHITECT PRIOR TO PURCHASING PLUMBING FIXTURES. PLUMBING FIXTURES ARE SELECTED BY OWNER AND ARCHITECT ON THIS PROJECT. MZIM; DEEP SE P-TRAP LAVATORY CONTRACTOR TO INSULATE ALL PIPING BELOW LAV.- TRAP PRIMER ASSEMBLY EQUAL TO ZURN Z-1021- FLOOR DRAIN NTH AM U 1^�Anl AILI�M ESCUTCHEON PLATE (TYP.) �_SLEEVE & SEAL THRU SLAB 1/2-0 SCH. 40 PVC PIPING FROM PRIMER TO AUXILIARY INLET FITTING ON FLOOR DRAIN. SLOPE HORIZONTAL PIPING AT 1/4- PER FT. MINIMUM \_ TRAP PRIMER CONNECTION TRAP PRIMER DETAIL NOT TO SCALE PLUMBING GENERAL NOTES 1. ALL PLUMBING INSTALLATIONS AND MATERIALS SHALL BE IN STRICT ACCORDANCE WITH ALL LOCAL, STATE AND FEDERAL CODES, LAWS, ORDINANCES AND REGULATIONS OF ALL AUTHORITIES HAVING JURISDICTION OVER THIS PROJECT. 2. PIPE ROUTING SHOWN ON THESE DRAWINGS IS SCHEMATIC AND IS NOT INTENDED TO INDICATE EXACT ROUTING. PLUMBING CONTRACTOR SHALL PROVIDE ANY ADDITIONAL OFFSETS AND FITTINGS REQUIRED FOR PROPER INSTALLATION AND TO MAINTAIN PROPER CLEARANCES. 3. COORDINATE ALL PIPE ROUTING WITH ALL OTHER TRADES PRIOR TO INSTALLATION. ROUTE ALL PIPING TO AVOID DUCTWORK, PIPING AND BUILDING STRUCTURE. 4. SEE ARCHITECTURAL DRAWINGS FOR EXACT PLUMBING FIXTURE LOCATIONS AND MOUNTING HEIGHTS FOR COMPLIANCE NTH FLORIDA BUILDING CODE ACCESSIBILITY REQUIREMENTS. SINKS REQUIRED TO BE ACCESSIBLE SHALL BE MOUNTED WITH COUNTER RIM NO HIGHER THAN 34 INC3AES ABOVE FINISH FLOOR. CONTROLS FOR FLUSH VALVES SHALL BE MOUNTED ON THE WIDE SIDE OF THE TOILET AREAS NO MORE THAN 44 INCHES ABOVE THE FLOOR. FOR ALL OTHER FIXTURE MOUNTING HEIGHTS SEE PLUMBING FIXTURE SCHEDULE. 5. ROUTE ALL PIPING CONCEALED ABOVE CEILING, WITHIN CHASES OR ABOVE NON -ACCESSIBLE CEILINGS, REFER TO ARCHITECTURAL DRAWINGS FOR CEILING TYPES. 6. ALL VALVES, WATER HAMMER ARRESTORS, CONTROLS AND CLEANOUTS CONCEALED WITHIN CHASES OR ABOVE NON -ACCESSIBLE CEILINGS SHALL HAVE 24 in. X 24 in. METAL ACCESS PANELS UNLESS INDICATED OTHERWISE ON DRAWINGS. PROVIDE UL 1 1/2 HOUR LABEL ACCESS PANELS IN 1 AND 2 HOUR CONSTRUCTION. 7. INSTALL SHUTOF VALVES ON ALL WATER LINES IN THE FOLLOWING LOCA11ONS: ALL MAJOR BRANCH RUNS SUCH AS BRANCHES SERVING A FLOOR, WING, OR A MAJOR SECTION OF BUILDING. ALL EQUIPMENT CONNECTIONS. OTHER LOCATIONS AS MAY BE INDICATED ON DRAWINGS. 8. INSTALL BALANCING VALVES AS INDICATED ON THE DRAWINGS AND AS REQUIRED FOR PROPER BALANCING OF THE VARIOUS SYSTEM. 9. PLUMBING CONTRACTOR SHALL SUPPLY AND INSTALL A MEANS OF BACKFLOW PROTECTION OF THE POTABLE WATER SYSTEM AS INDICATED ON DRAWINGS AND AS REQUIRED PER 2020 FLORIDA BUILDING CODE (7th EDITION) - PLUMBING: SECTION 608. 10. AT ALL PUBLIC HAND WASHING FACILITIES PLUMBING CONTRACTOR SHALL SUPPLY AND INSTALL A APPROVED WATER TEMPERATURE LIMITING DEVICE. EITHER A THERMOSTATIC OR MECHANICAL MIXING VALVE THAT CONFORMS TO ASSE 1070 OR CSA B125.3. REFER TO 2020 FLORIDA BUILDING CODE (7th EDITION) - PLUMBING: SECTION 416(5). 11. PLUMBING CONTRACTOR SHALL PROVIDE VALVE DIRECTORY NTH A TAG SCHEDULE SHOWING LOCATION OF EACH VALVE, TYPE, NUMBER, MANUFACTURER, FUNCTION AND ALL OPERATING POSITIONS. 12. PLUMBING CONTRACTOR SHALL PROVIDE SLEEVES FOR ALL PIPES PASSING THROUGH FLOORS, WALLS AND CEILINGS. EXTEND SLEEVES 2" ABOVE FLOORS. MAKE ALL SLEEVES FLUSH WITH WALLS AND CEILINGS. CONTRACTOR SHALL FIRE STOP ALL PENETRATIONS OF RATED WALLS, CEILINGS, ETC., INCLUDING ROOF. FLASH AND COUNTER FLASH ALL ROOF PENETRATIONS. 13. PLUMBING CONTRACTOR SHALL PROVIDE CHROME PLATED HINGED ESCUTCHEON WITH SET SCREWS AT EACH EXPOSED PIPE PASSING THROUGH A WALL, FLOOR OR CEILING IN FINISHED PORTIONS OF THE BUILDINGS. 14. PLUMBING CONTRACTOR SHALL PROVIDE BELLOW TYPE WATER HAMMER ARRESTORS ON ALL HOT AND COLD WATER LINES. INSTALL IN UPRIGHT POSITION AT ALL QUICK CLOSING VALVES, SOLENOIDS, ISOLATED PLUMBING FIXTURES AND SUPPLY HEADERS AT PLUMBING FIXTURE GROUPS. LOCATE AND SIZE AS SPECIFIED OR AS SHOWN ON THE DRAWINGS AND WERE NOT SHOWN, LOCATE IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS AND COMPLY NTH THE PLUMBING AND DRAINAGE INSTITUTE STANDARDS 0 201. 15. AT ADA FIXTURES WERE SHOWN ON THE DRAWINGS, OR WHERE REQUIRED BY GOVERNMENTAL AGENCIES HAVING JURISDICTIONS, PROVIDE PREMANUFACTURED INSULATION KITS ON THE SUPPLIES, TRAP AND DRAIN AT LAVATORIES AND SINKS FOR HANDICAPPED PERSONS. -0-) FROM 16. ALL VENTS THROUGH ROOF SHALL BE A MINIMUM OF TEN FEET (10' ANY AIR INTAKE. 17. PLUMBING CONTRACTOR SHALL INSTALL DIELECTRIC UNIONS AT ALL CONNECTIONS OF DISSIMILAR METALS. 18. ALL HOT WATER AND HOT WATER RETURN LINES SHALL BE INSULATED WITH 1* WALL THICKNESS, PRE -SLIT, FLEXIBLE UNICELLULAR POLYOLEFIN FOAM PLENUM RATED ARMAFLEX INSULATION. 19. PLUMBING CONTRACTOR SHALL THOROUGHLY INVESTIGATE THE SITE, CAREFULLY STUDY THE ARCHITECTURAL, MECHANICAL, ELEC'MICAL, CABINET AND PLUMBING DRAWINGS, AND BECOME THOROUGHLY FAMILIAR WITH THE EXISTING CONDITIONS AND NEW WORK BEFORE BIDDING. NO CHANGES WILL BE ALLOWED IN CONTRACT PRICE FOR EXTRA WORK CLAIMS BECAUSE CONTRACTOR FAILED TO FOLLOW THESE DIRECTIONS. 20. EXISTING CONDITIONS AS SHOWN ON THESE DRAWINGS ARE TAKEN FROM ORIGINAL AND AS-BUILTS DRAWINGS OF THE BUILDING. THESE DRAWINGS, IN PART, ARE UNVERIFIED AND FIELD CONDITIONS SHALL GOVERN. FIELD VERIFY EXIS71NG INSTALLA11ONS OF ALL DESCRIPTION AND MODIFY EXISTING PLUMBING SYSTEMS MICH ARE TO REMAIN ACTIVE, TO FACILITATE RECONNECTION AND EXTENSION UNDER NEW WORK. PROVIDE SHUT -OF VALVES ON AU PIPES AT THE POINT OF TIE-IN TO EXISTING SYSTEM. 21. INTERRUPTION OF EXISTING SERVICES SHALL BE MINIMAL AND SHALL BE FULLY COORDINATED WITH OMER IN ADVANCE. PLUMBING CONTRACTOR SHALL SUBMIT TIME THAT SERVICE WILL BE DOWN, AREA OF PIPING AND ANY EQUIPMENT THAT WILL BE AFFECTED. SCHEDULE ANY INTERRUPTION DURING NON -CRITICAL HOURS OR NOTIFY OMER AT LEAST TWENTY-FOUR (24) HOURS PRIOR TO INTERRUPTION. PUT INTERRUPTED SERVICES BACK INTO OPERATION AS SOON AS IS PRACTICAL. NO SHUT DOWN CAN BE DONE WITHOUT THE OWNER'S APPROVAL. 22. DURING THE PROGRESS OF WORK THE PLUMBING CONTRACTOR SHALL MAINTAIN AN ACCURATE RECORD OF ALL CHANGES MADE TO THE PLUMBING SYSTEM. THE RECORD DRAWINGS SHALL SHOW, CHANGES, DIMENSIONS AND LOCATIONS OF ALL PIPING. CHANGES SHALL BE DONE IN AUMCAD RELEASE 2007 OR ABOVE AND SUBMITTED TO THE OWNER AND GENERAL CONTRACTOR AT FINAL COMPLETION. PLUMBING LEGEND SYMBOL ABBRV. DESCRIPTION SAN SAN SANITARY WASTE CW COLD WATER HIN HOT WATER HWR HOT WATER RETURN V VENT LINE BALL VALVE (FULL PORT) WATER HAMMER ARRESTOR 40 WCO WALL CLEAN OUT D13--- FCO FLOOR CLEAN OUT PLUMBING SPECIFICATIONS GENERAL CODES AND STANDARDS: ALL PLUMBING WORK SHALL BE IN STRICT COMPLIANCE WITH THE 2020 (7TH EDITION) FLORIDA BUILDING CODE AND 2020 FLORIDA ACCESSIBILITY CODE (7TH EDITION) FOR BUILDING CONSTRUCTION CHAPTER 11. THE CONTRACTOR SHALL OBTAIN ALL REQUIRED PERMITS, INSPECTIONS AND PAY ALL FEES. WATER SUPPLY SYSTEM: EXTEND WATER SERVICE AS INDICATED ON DESIGN DRAWINGS. PROVIDE SHOCK ABSORBERS AND VACUUM BREAKERS WHERE REQUIRED. PIPE AND FITTINGS ABOVE GROUND - TYPE L HARD COPPER AND WROUGHT COPPER FITTINGS, WITH SOLDERED JOINTS (USE ONLY -LEAD FREE- SOLDER). CPVC PIPING IS ACCEPTABLE FOR THIS APPLICATION AS WELL VALVES (3 INCH AND LARGER) - GATES VALVES - LEAD FREE, ALL BRONZE, RISING STEM, DOUBLE WEDGE TAPER SEAT, 125 PSI STEAM PRESSURE. VALVES (2-1/2 INCH AND SMALLER) TWO PIECE 400 PSI WSP FULL PORT BRONZE BODY BALL VALVE, LEAD FREE* WITH THREADED ENDS, LOCKABLE LEVER HANDLE AND REPLACEABLE TEFLON OR TFE SEATS CHLORINATION - BEFORE BEING PLACED IN SERVICE ALL WATER DISTRIBUTION SYSTEMS SHALL BE STERILIZED WITH CHLORINE IN ACCORDANCE WITH PLUMBING CODE AND AWWA C-651 OR C-652 STANDARD PROCEDURE FOR DISINFECTING WATER MAINS. *LEAD FREE REFERS TO THE WETTED SURFACE OF PIPE, FITTINGS, AND FIXTURES IN POTABLE WATER SYSTEMS THAT HAVE A WEIGHTED AVERAGE LEAD CONTENT LESS THAN 0.25% PER THE SAFE DRINKING WATER ACT AND OTHER EQUIVALENT STATE REGULATIONS. CONNECTIONS TO MISCELLANEOUS EQUIPMENT - ROUGH -IN AND CONNECT WATER, WASTE, AND VENT TO COMPLETE THE INSTALLATION OF EQUIPMENT LISTED ON THE DRAWINGS. PLUMBING FIXTURES SHALL BE PROVIDED COMPLETE AS SHOWN ON THE DRAWINGS NTH ALL REQUIRED SUPPLY, WASTE, SOIL, AND VENT CONNECTIONS, TOGETHER WITH ALL FITTINGS, SUPPORTS, FASTENING DEVICES, COCKS, VALVES, AND TRAPS. ALL FIXTURES SHALL HAVE STOP VALVES ON ALL WATER CONNECTIONS. ALL EXPOSED METAL TRIM ON ALL FIXTURES SHALL BE POLISHED CHROMIUM PLATED. ALL EXPOSED PIPES EXTENDING FROM WALL SHALL HAVE CHROMIUM PLATED BRASS ESCUTCHEON MOUNTED AGAINST WALL. EXPOSED PVC PIPING AND P-TRAPS ARE UNACCEPTABLE. THE PLUMBING FIXTURES SHALL BE ROUGHED -IN ACCORDANCE WITH MANUFACTURER'S *ROUGH -IN INFORMATION'. PROVISIONS FOR MOUNTING WALL FIXTURES SHALL BE MADE MILE THE WALL IS BEING BUILT. PROVIDE ADDITIONAL BLOCKING, HANGERS, AND SUPPORTS AS REQUIRED. DRAINAGE SYSTEM: EXTEND PIPING FROM NEW FIXTURES AND EQUIPMENT AND CONNECT TO SYSTEMS AS INDICATED ON THE DRAWINGS. PIPE SLOPE: 2-1/2 INCH DIAMETER AND LESS SHALL BE INSTALLED WITH A FALL OF NOT LESS THAN 1/4 INCH PER FOOT. 3 INCH DIAMETER OR LARGER SHALL BE INSTALLED WITH A FALL NOT LESS THAN 1/8 INCH PER FOOT. PIPE AND FITTINGS: ABOVE GRADE: SCHEDULE 40 PVC, DWV COPPER, OR SERVICE WEIGHT CAST IRON ALL CAST IRON SOIL PIPE AND FITTINGS SHALL BE MARKED WITH THE COLLECTIVE TRADEMARK OF THE CAST IRON SOIL PIPE INSTITUTE (CISPI) AND BE LISTED BY NSF INTERNATIONAL SERVICE -WEIGHT CAST IRON WITH NO/HLIB OR BELL AND SPIGOT FITTINGS. NO/HUB COUPLING SHALL CONFORM TO CISPI STANDARD 310 (LATEST EDITION) AND SHALL BE LISTED BY NSF INTERNATIONAL. DRAIN, WASTE AND VENT PIPING LOCATED IN FIRE RATED WALL ASSEMBLIES AND RETURN AIR PLENUMS SHALL BE SERVICE -WEIGHT CAST IRON WITH SPIGOT FITTINGS OR HUBLESS SOIL PIPE COUPLINGS AS MANUFACTURED BY MISSION (HW), HUSKEY OR CLAMPALL (125# OF TORQUE). BELOW GRADE: SCHEDULE 40 PVC OR SERVICE WEIGHT CAST IRON WITH HUB AND SPIGOT FITTINGS OR HUBLESS SOIL PIPE COUPLINGS AS MANUFACTURED BY MISSION (HW), HUSKEY OR CLAMPALL (125# OF TORQUE). ALL CAST IRON SOIL PIPE AND FITTINGS SHALL BE MARKED WITH THE COLLECTIVE TRADEMARK OF THE CAST IRON SOIL PIPE INSTITUTE (CISPI) AND BE LISTED BY NSF INTERNATIONAL. PROVIDE CLEANOUTS EVERY 75 FEET, AT CHANGES IN DIRECTION, AT BASE OF DOWNSPOUTS AND AT BASE OF SOIL AND WASTE STACKS. SHOCK ARRESTOR: MIFAB, SIOUX CHIEF OR EQUAL WALL CLEANOUT: MIFAB, ZURN, JONESPEC, JOSAM OR EQUAL FLOOR CLEANOUT. MIFAB, ZURN, JONESPEC, JOSAM OR EQUAL VENTS SHALL BE EXTENDED TO EXTERIOR OF BUILDING. AJR ADMITTANCE VALVES ARE ACCEPTABLE. BUILDING OWNER'S SPECIFICATIONS AND CRITERIA FOR MATERIALS AND PROCEDURES SHALL GOVERN MEN IN CONFLICT WITH MECHANICAL SPECIFICATIONS AND NOTES. IT IS THE CONTRACMR'S RESPONSIBILITY TO OBTAIN A COPY OF THE OWNER'S SPECIFICATIONS PRIOR TO SUBMITTING BID. um. PLUMBING CONTRACTOR SHALL FIELD VERIFY, USING SUCH METHODS AS A SEWER CAMERA, LOW FREQUENCY GPR (GROUND PENETRATING RADAR) OR EM (ELECTROMAGNETIC) UTILITY LOCATING METHODS DURING DEMOLITION PHASE OF PROJECT TO DETERMINE THE EXACT CONDITION OF PIPE, LOCATION, SIZE, INVERT AND DIRECTION OF FLOW OF ALL EXISTING SANITARY/GREASE WASTE LINES WITHIN SCOPE OF PROJECT. DISCREPANCIES AND UNFORESEEN CONDITIONS ARE TO BE BROUGHT TO THE ATTENTION OF THE OWNER, ARCHITECT AND PROJECT ENGINEER PRIOR TO PROCEEDING NTH DEMOLITION IN THE AREA OF CONCERN. ------ CAMPBELL + VAN DUESEN A kC.H I I FCTI-I ? F 1',JT=Rlr.R DF':.I'�4NI www.CVDstudio.com CAMPBELL + VAN DUSEN Design Studio, LLC. 255 South Orange Avenue Suite # 1240 Orlando, Florida 32801 Phone: 407.930.6016 FL. Lic. No. AA26003339 ARCHITECT OF RECORD FRANK W. CAMPBELL AIA FL LIC NO. AROO 16053 COPY OF THIS PLAN IS NOT VALID UNLESS SIGNED, SEALED AND DATED BY THE ARCHITECT OF RECORD , � N0 .............. S� " XG E 1Y oe (p No. 90018 -0 *P STATE OF 0 ::� * 0 R 1`0 "'40Z ................. .. C-j N 10 101VAL Taylor J. Lewis, PE, FL Reg. No. 90018 COPY OF THIS PLAN IS NOT VALID UNLESS SIGNED, SEALED AND DATED BY THE ENGINEER OF RECORD U_ >_ 0 CL Uj W < LLI LL1 > __j ca I-- F- + Ljr) _T_ I _j () 2: ".0 rk, < LLI LLJ 0 ) 0 > m LU W < 3: Lr__U4 cr-01 cl- (12) CONSTRUCTION DOCUMENTS 03.24.2023 DATE PRINCIPAL IN CHARGE F. CAMPBELL . ..... .. ...... P . ROJECT . MA . NAGER ...... ................... ....................... M.. T.O. R.R E.S ...................................................... ADVENT HEALTH WELL 65+ ZEPHYRHILLS 22-0328-01 PLUMBING SPECIFICATIONS p 1 0 1 rio 9 8 7 6 5 4 3 2 1 T T T T T- - T31 BIO ELEC. ROOM/ 1WCO FIRE RISER S-3 I" WELLNESS SUITE 4 �ELLNESS WELLNESS SUITE SUITE WELLNESS SUITE WELLNESS SUITE L 5 1 6 7 8 CONSUI 3"SAN S-3 S-3 T W03--2 T Wc- T CORRIDOR \FCO,.., 1 126 CARE - -3"SAN 3 'SA� FCO COORDINATORS K3*SAN X3*SAh K 3"SAN SAN— I SAN CORRIDOR -T -i WELLNESS SUITE 3 PRACTICE f4co ADMINISTRATOR 3"SAN S-3 MED ROOM STORAGE2 CORRIDOR HUDDLE CORRIDOR 3*SAN E 5=-4 < cn 3"SAN- WELLNESS SUITE PROVIDER WORK 2 ROOM 108 3D S-3 — - — - — - — - — - — - - — - — - — - 5=4 - — - — - — - — - — EJ I LAB HD-1 i.c.1 —�o 3mSAN SAN 3"SAN TOILET 120 COMMI-01.1 AUTOCLAVE 3"SAN WELLNESS SUITE FD-1 L= 11 1 5=4 U) - - - - - - - - - U7 3"SAN 0 ? 3"SAN CORRIDOR I 3"SAN 1 el 0 I 9 SAN FD-1 WC-1 FCO 3*SAN STORAGE1 3 .IAN 3"SAN �SAN 3"SAN 3"SAN CONSULT/BROKER 3 TOILET 130 F C C EWC-1 3"SAN COMMUNITY FCO 1co r/-4*SAN FD-1 FD-1 TOILET L=1 TOILET LOBBY S-1 3*SAN WC WCO --LSAN LJ(: 0 BREAK ROOM - — - — - — - — - — - — - — - — - - — - — - — - - — - — - — - — - - — - — - — M--------------- A - — - — - — - — - — - --------------- j I - — - — - — - - — - — - - - - - - - - - - - - - - - - ------- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - --- _7 - - - - - - PRESUMED LOCATION OF EXISTING 4"SANITARY WASTE LINE L- - - - - - - - - - - - - - - - - - - - - -1 L - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - j L - - - - - - - - - - - - - - - - - - - - SANITARY WASTE RENOVATION PLAN P2.1) 1/411 = 11-011 FOA B C C --- Do [0E OF G) GENERAL NOTES: 1. CONTRACTOR SHALL VISIT THE SITE PRIOR TO BIDDING AND CONSTRUCTION TO SURVEY EXISTING CONDITIONS. 2. CONTRACTOR SHALL INSTALL APPLIANCES PER KEY NOTES: (DCONTRACTOR SHALL TIE NEW 3- SANITARY WASTE LINE INTO NEAREST EXISTING SANITARY LINE OF ADEQUATE SIZE. FIXTURES PIPE SIZE FIXTURE SAN SIZE VENT SIZE WATER CLOSET 3m 2" LAV / SINK 3" 1-1/2- 30 1-1/2' FLOOR DRAIN 30 2- _j NOTE. PLUMBING CONTRACTOR SHALL FIELD VERIFY, USING SUCH METHODS AS A SEWER CAMERA, LOW FREQUENCY GPR (GROUND PENETRATING RADAR) OR EM (ELECTROMAGNETIC) UTILITY LOCATING METHODS DURING DEMOLITION PHASE OF PROJECT TO DETERMINE THE EXACT CONDITION OF PIPE, LOCATION, SIZE, INVERT AND DIRECTION OF FLOW OF ALL EXISTING SANITARY/GREASE WASTE LINES WITHIN SCOPE OF PROJECT. DISCREPANCIES AND UNFORESEEN CONDITIONS ARE TO BE BROUGHT TO THE ATTENTION OF THE OWNER, ARCHITECT AND PROJECT ENGINEER PRIOR TO PROCEEDING WITH DEMOLITION IN THE AREA OF CONCERN. CAMPBELL + VAN DUSEN A kC H I'T F(7 T11 ? F 1,JT=Rlr.R DFnIr4N www.CVDstudio.com CAMPBELL + VAN DUSEN Design Studio, LLC. 255 South Orange Avenue Suite # 1240 Orlando, Florida 32801 Phone: 407.930.6016 FL. Lic. No. AA26003339 ARCHITECT OF RECORD FRANK W. CAMPBELL AIA FLLIC NO. AR0016053 COPY OF THIS PLAN IS NOT VALID UNLESS SIGNED, SEALED AND DATED BY THE ARCHITECT OF RECORD z SP-MES4 . .............. zz� 9()0j 8 OF Uj -0 STP'TE /14- %, "t.L 0 ?0)-� N A\- Ta�or J. Lewis, PE, FL Reg. No. 90018 COPY OF THIS PLAN IS NOT VALID UNLESS SIGNED, SEALED AND DATED BY THE ENGINEER OF RECORD -j LL- 0 L:k= Uj t-4 U < Q V� LLJ > —j Q L0 U :2-7 LU LLJ > 0 C) LU .10 'IT '0 Lf) W CL < 3�: rL-U4 ot-01 1c'V11)) CONSTRUCTION DOCUMENTS 03.24.2023 PRINCIPAL IN CHARGE F. CAMPBELL .. ................................................................. PROJECT MANAGER M. TORRES .................................................................... ADVENT HEALTH WELL 65+ ZEPHYRHILLS 22-0328-01 MEP CONSULTING SANITARY WASTE ENGINEERS SINCE 1977 RENOVATION PLAN L REG NO. 3089 2016 ALDEN RD. ORLANDO, FL 32803 (407) 246-1688 WWW.PEIRACOM P2*1 PEI PROJECT # 22121 L di III! m��. =0011�211111119 IN, n MR 1111441 rio3 2 9 8 7 6 4 - - - - -- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Tf CIRCUIT& SOLVER ELEC. ROOM/ ... jr r WELLNESS SUITE WELILNESS SUITE 5 6 FIRE RISER WELLNESS SUITE 4 WELLNESS SUITE CONSULTI-01.1 7 WELLNESS SUITE 8 .—CW--- HW--- ----HWR---- 5=13 1/2-CW,HW,HWR JL rc T rff=% 5 1/2-CW,HW,HWR UN Le BALL VALVE (TYP) L.L L., 1/2"C WHW LR. J6 1/2*CWHW CORRIDOR CARE COORDINATORS ---CW ;El/eCWHW 4�71/2-'CAHW CORRIDOR WELLNESS SUITE CIRCUIT 3 SOLVER PRACTICE ADMINISTRATOR 5t3 MED ROOM BIO 118 L CORRIDOR HUDDLE 121 CORRIDOR 1/2"CW,HW —CW 1/2"CWHW 5=4 STORAGE 2 3/4-CWNHW WELLNESS SUITE 2 CIRCUIT SOLVER rid N1 94— LAB LLJ PROVIDER WORK ROOM r — - — - — - — - — - — - 119 -1/ C W - — - — - — - — - — L I 1/2-CW DOWN 1:11W HWR 4 ECIR PU P L TO MS-1 - cm 1 1/2-CWHWHWR /2-CW, TOILET WC-1 Comm I 10C HWH 1/2nCWHWHWR AUTOCLAVE CW--j WELLNESS SUITE CIRCUIT SOLVER HW /--\CIRCUIT F7 ... HWR /2��SOLVER 5=4 L S-3 3/ecvtHWHWR rI-- CORRIDOR 3/4-CW HWJ 1/2"CWHWHVR .,(DCIRCUIT SOLVER 1"CW 1/2 CW 3/4-HW CIRCUIT 5 4 - 1/2"CWHWHWR cw�—. - — . . .. . .. . .. - - — - - — - 3/4" HWR-� ^W—. --HW— - - SOLVER 1/20CWHWHWR H W WC-1 TOILET 130 STORAGE1 ... . ... 1/2*CWHWHWR . ... . .... ... . ... CONSULT/BROKER HWR— CW 1/2-CW IM-1 EK F9 Id J 0 I I WC-1 WC-1 TOIL IM-1 FLOODSTOP 1/2"CWHW CIRCUIJ&/5=2 SOLVE TOILET F 103 C-) LL� LOBBY cm t 0 BREAK ROOM L111 /2"CWHW COMMUNITY �DCIRCUI SOLVER (TYP) 7: — - — - — - — - — - — - — - — - — -- 1/2"CWHW - — - — - — - — - - — - — - — - — - — - — --- - — -- — - — - — -- r — - — - — - - -- ------ t — - — - — - — - — - — - — - — - — - — - — - — - DOMESTIC WATER RENOVATION PLAN 1/411 = 1 1-011 FOA - —OD OE OF G GENERAL NOTES: 1. CONTRACTOR SHALL VISIT THE SITE PRIOR TO BIDDING AND CONSTRUCTION TO SURVEY EXISTING CONDITIONS. 2. CONTRACTOR SHALL INSTALL RECIR. PUMP IN A EASY ACCESSIBLE LOCATION. 3. CONTRACTOR SHALL INSTALL VALVES FOR PIPING IN EASY ACCESSIBLE LOCATIONS AND WITHIN A CERTAIN DISTANCE TO MEET CODE. IF AN ACCESS DOOR IS NEEDED ONE SHALL BE INSTALLED. 4. CONTRACTOR SHALL INSTALL APPLIANCES PER MANUFACTURER'S PLUMBING REQUIREMENTS. KEY NOTES: (D CONTRACTOR SHALL PROVIDE 1/2" COLD WATER LINE WITH LEAD FREE DUAL CHECK BACKFLOW PREVENTER TO NEW ICE MACHINEACE MAKER. BACKFLOW PREVENTER SHALL BE WATTS LF007 OR APPROVED EQUAL CONTRACTOR SHALL PROVIDE LEAK/FLOOD DETECTION PROTECTION WITH "FLOODSTOP" DEVICE. COORDINATE WITH BUILDING OMER ON SPECIFIC LOCATIONS AND MODEL NUMBERS PER PLUMBING RENOVATIONANSTALLATION. CONTRACTOR SHALL INSTALL AND CONNECT NEW ELECTRIC WATER HEATER (EWH-1). SEE SHEET P1.1 FOR MORE INFORMATION. CONTRACTOR SHALL INSTALL NEW RECIRCULATING PUMP. SEE ELECTRIC WATER HEATER DETAIL FOR MORE INFORMATION ON SHEET P1.1. CIRCUIT SOLVER THERMOSTATIC BALANCING VALVE NTH INTEGRATED UNION, LEAD FREE BALL VALVE AND CHECK VALVE INSERT. MODEL NO. CSUA-1/2-120-CV1-03 (OR APPROVEDEQUAL). CONTRACTOR SHALL TIE NEW 1-1/4- COLD WATER LINE INTO NEAREST EXIS11NG COLD WATER LINE OF ADEQUATE SIZE. CONTRACTOR SHALL PROVIDE 1/2" COLD WATER LINE WITH LEAD FREE DUAL CHECK BACKFLOW PREVENTER TO NEW COFFEE MACHINE/COFFEE MAKER. BACKFLOW PREVENTER SHALL BE WATTS SD-3 OR APPROVED EQUAL COORDINATE FINAL LOCATION WITH ARCHITECT. FIXTURES' SUPPLY PIPE SIZE FIXTURE CW HW HWR� WATER CLOSET 1/2" ELECT WATER COOLER 1/210 -- -- LAV / SINK 1/2- 1/2- 1/2- MOP SINK 1/2" 1 1/2" CAMPBELL + VAN DUSEN ARCH ITECTLI RE IN-EiIDR DE3113N www.CVDstudio.com CAMPBELL + VAN DUSEN Design Studio, LLC. 255 South Orange Avenue Suite # 1240 Orlando, Florida 32801 Phone: 407.930.6016 FL. Lic. No. AA26003339 ARCHITECT OF RECORD FRANK W. CAMPBELL AIA FL LIC NO. AR001 6053 COPY OF THIS PLAN IS NOT VALID UNLESS SIGNED, SEALED AND DATED BY THE ARCHITECT OF RECORD �\\w �\X p. 3 A M 0 ............. tCE No. 90018 4LO STATE OF " :Z: 4V Ak- 4 0 R I ID .................. ZON L /////I ImO Taylor J. Lewis, PER FL Reg. No. 90018 COPY OF THIS PLAN IS NOT VALID UNLESS SIGNED, SEALED AND DATED BY THE ENGINEER OF RECORD __j LL- c/i -j 0 CL Lij F— < C/) LU LU LU LU 0 > C) U-1 0 Lx) W CL < 3-- LU r-4 co (y) r--, Cy) CONSTRUCTION DOCUMENTS 03.24.2023 PRINCIPAL IN CHARGE F. CAMPBELL ........................ I ........................................... PROJECT MANAGER M. TORRES ................ ................................................. ADVENT HEALTH WELL 65+ ZEPHYRHILLS 22-0328-01 MEP CONSULING DOMESTIC WATER EN61NEERS SINCE 1977 RENOVATION PLAN FL REG NO. 30811 2016 ALDEN RD. ORLANDO, FL 32803 (407) 246-1688 WWW.PEIFLA.COM P2e2 PEI PROJECT 22121 'IV-' PC V"" '-3_.,',lAN ZAN SANITARY WASTE RISER DIAGRAM P3.1 ) NTS jj� OV ,V, �ON tA�� OP WA�� UNZ lco GENERAL NOTES: 1. CONTRACTOR SHALL VISIT THE SITE PRIOR TO BIDDING AND CONSTRUCTION TO SURVEY EXISTING CONDITIONS. 2. CONTRACTOR SHALL INSTALL APPLIANCES PER MANUFACTURER'S PLUMBING REQUIREMENTS. KEY NOTES: (DCONTRACTOR SHALL TIE NEW 3- SANITARY WASTE LINE INTO NEAREST EXISTING SANITARY LINE OF ADEQUATE SIZE. FIXTURES PIPE SIZE FIXTURE SAN SIZE VENT SIZE WATER CLOSET 3m 2" LAV / SINK 318 1-1/2* ELECT WATER COOLER 3" 1-1/2" FLOOR DRAIN 30 2" NOTE P N L M PE E - U N LOC 7 M E A TH B 0 TR _n I D N N S G A ri PLUMBING CONTRACTOR SHALL FIELD VERIFY, USING SUCH METHODS AS A SEWER CAMERA, LOW FREQUENCY GPR (GROUND PENETRATING RADAR) OR EM (ELECTROMAGNETIC) UTILITY I LOCATING METHODS DURING DEMOLITION PHASE OF PROJECT TO D MI ETERMINE THE EXACT COND171ON OF PIPE, LOCATION, SIZE, T INVERT AND DIRECTION OF FLOW OF ALL EXIS71NG T S S IT Y ANITARY/GREASE WASTE LINES WITHIN SCOPE OF PROJECT. SC P DISCREPANCIES AND UNFORESEEN CONDITIONS ARE TO BE I OU T BROUGHT TO THE ATTENTION OF THE OWNER, ARCHITECT AND P OJ PROJECT ENGINEER PRIOR TO PROCEEDING WTH DEMOLITION IN CT rTHEAREA OF CONCERN. I CAMPBELL + VAN DUSEN ARCH ITECTLI RE It-l-ERIDR DIE.31GYN www.CVDstudio.com CAMPBELL + VAN DUSEN Design Studio, LLC. 255 South Orange Avenue Suite # 1240 Orlando, Florida 32801 Phone: 407.930.6016 FL. Lic. No. AA26003339 ARCHITECT OF RECORD FRANK W. CAMPBELL AIA FL LIC NO. AR001 6053 COPY OF THIS PLAN IS NOT VALID UNLESS SIGNED, SEALED AND DATED BY THE ARCHITECT OF RECORD \0 I I I I I ///,, �,N\o . .......... E IV'"" No. 90018 STATEi OF 0% 0 RVD�_ ........... N 10 N A L Taylor J. Lewis, PE, FL Reg. No. 90018 COPY OF THIS PLAN IS NOT VALID UNLESS SIGNED, SEALED AND DATED BY THE ENGINEER OF RECORD _j U_ Vi _j _j 0 F— r) Uj U < 0 L,e) > LU LIJ _j 0 Q0 + L0 ,0 cle < LU Lij c) 0 >-0 lc;r m LU 'o Lr) W < 3:: ((yy)) CL ru--4j ro-01 CONSTRUCTION DOCUMENTS 03.24.2023 DESCRIPTION PRINCIPAL IN CHARGE F. CAMPBELL .................................................................... PROJECT MANAGER M. TORRES ......... I .......................................................... ADVENT HEALTH WELL 65+ ZEPHYRHILLS 22-0328-01 MEP CONSULTING SANITARY WASTE ENGINEERS SINCE 1977 RISER DIAGRAM FL REG NO. 3089 2016 ALDEN RD. ORLANDO, FL 32803 (407) 246-1688 WWW.PEIRACOM P3e I PEI PROXCT t 22121 .. >0000 0, ,00�, --..-0, 000, 0, ..>000" 100 '00AZ,�� WAIN HsZ4 Ab 10 -00, 00' 4% 4" k_q *ATN HA44PA NLL 00 ,OWN H.A0001 AO 40AL) 1�/,' " ka cw HW .x "O"o, 1/z,cw HVI 6 "50 0e, ;,O� I f �11 c 0 . -N1. I'll , 000� > .--000� DOMESTIC WATER RISER DIAGRAM 1/4', = V-0. , I t��4 j GENERAL NOTES: 1. CONTRACTOR SHALL VISIT THE SITE PRIOR TO BIDDING AND CONSTRUCTION TO SURVEY EXISTING CONDITIONS. 2. CONTRACTOR SHALL INSTALL RECIR. PUMP IN A EASY ACCESSIBLE LOCATION. 3. CONTRACTOR SHALL INSTALL VALVES FOR PIPING IN EASY ACCESSIBLE LOCATIONS AND WITHIN A CERTAIN DISTANCE TO MEET CODE. IF AN ACCESS DOOR IS NEEDED ONE SHALL BE INSTALLED. 4. CONTRACTOR SHALL INSTALL APPLIANCES PER MANUFACTURER'S PLUMBING REQUIREMENTS. KEY NOTES: CD CONTRACTOR SHALL PROVIDE 1/2* COLD WATER LINE NTH LEAD FREE DUAL CHECK BACKFLOW PREVENTER TO NEW ICE MACHINE/ACE MAKER. BACKFLOW PREVENTER SHALL BE WATTS LF007 OR APPROVED EQUAL CONTRACTOR SHALL PROVIDE LEAK/FLOOD DETECTION PROTECTION NTH "FLOODSTOP" DEVICE. COORDINATE NTH BUILDING OWNER ON SPECIFIC LOCATIONS AND MODEL NUMBERS PER PLUMBING RENOVATIONANSTALLATION. CONTRACTOR SHALL INSTALL AND CONNECT NEW ELECTRIC WATER HEATER (EWH-1). SEE SHEET P1.1 FOR MORE INFORMATION. CONTRACTOR SHALL INSTALL NEW RECIRCULATING PUMP. SEE ELECTRIC WATER HEATER DETAIL FOR MORE INFORMATION ON SHEET P1.1. CIRCUIT SOLVER THERMOSTATIC BALANCING VALVE NTH INTEGRATED UNION, LEAD FREE BALL VALVE AND CHECK VALVE INSERT. MODEL NO. CSUA-1/2-120-CV1-03 (OR APPROVED EQUAL). CONTRACTOR SHALL TIE NEW 1-1/4" COLD WATER LINE INTO NEAREST EXISTING COLD WATER LINE OF ADEQUATE SIZE. (DCONTRACTOR SHALL PROVIDE 1/2- COLD WATER LINE WITH LEAD FREE DUAL CHECK BACKFLOW PREVENTER TO NEW COFFEE MACHINE/COFFEE MAKER. BACKFILOW PREVENTER SHALL BE WATTS SD-3 OR APPROVED EQUAL. COORDINATE FINAL LOCATION WITH ARCHITECT. FIXTURES' SUPPLY PIPE SIZE FIXTURE CW HW HWR WATER CLOSET 1/2" ELECT WATER COOLER 1/2* -- -- LAV / SINK 1/230 1/20 1/20 MOP SINK 1/2" 1 1/21p -- —j CAMPBELL + VAN DUSEN A k C, H IT F (7 T 1.1 Z F 1'%1T=RIC.R r�F`-,,I�,4N www.CVDstudio.com CAMPBELL + VAN DUSEN Design Studio, LLC. 255 South Orange Avenue Suite # 1240 Orlando, Florida 32801 Phone: 407.930.6016 FL. Lic. No. AA26003339 ARCHITECT OF RECORD FRANK W. CAMPBELL AIA FL LIC NO. AROO 16053 COPY OF THIS PLAN IS NOT VALID UNLESS SIGNED, SEALED AND DATED BY THE ARCHITECT OF RECORD ................ fc. N STPTF- 01, 0i-- PLO F,\,o 0*"� !Z:� zz... . ........ //j; �910NIA%- "\\V Taylor J. LeVis, PE, FL Reg. No. 90018 COPY OF THIS PLAN IS NOT VALID UNLESS SIGNED, SEALED AND DATED BY THE ENGINEER OF RECORD __j Lj- c/i -j 0 r CL CL LU r-4 U < C/) LU L.LJ > -i c) = co + LO -j -j U -7, "o cle < LU LU > 0 C) LU --0 1qT 0 Lr) w < 3:: or-?, CL tu-J4 ((YY)) CONSTRUCTION DOCUMENTS 03.24.2023 PRINCIPAL IN CHARGE F. CAMPBELL ........... ......... I .............................................. PROJECT MANAGER M. TORRES .................................................................... ADVENT HEALTH WELL 65+ ZEPHYRHILLS 22-0328-01 MEP CONSULTING DOMESTIC WATER ENGINEERS SINCE 1977 RISER DIAGRAM FIL REG NO. 3089 2016 ALDEN RD. ORLANDO, FL 32803 (407) 246-1688 WWW.PBFLA.COM P12 PEI PROECT 22121 FIRE PROTECTION SPECIFICATIONS GENERAL DRAWINGS AND GENERAL PROVISIONS OF CONTRACT, INCLUDING GENERAL AND SUPPLEMENTAL CONDITIONS AND DIVISION I SPECIFICATIONS, APPLY TO WORK SPECIFIED IN THIS SECTION. SCOPE OF WORK: WORK REQUIRED UNDER THIS SECTION INCLUDES PROVIDING ALL LABOR, MATERIALS, EQUIPMENT, FEES AND SERVICES FOR, AND REASONABLY INCIDENTAL TO, PROPER COMPLE11ON OF ALL FIRE PROTECTION WORK HEREIN SPECIFIED, EXCEPTING ONLY WORK OR MATERIALS SPECIFIED OR NOTED AS BEING FURNISHED AND/OR INSTALLED BY OTHERS. 1. ALL WORK SHALL BE PERFORMED BY COMPETENT WORKMEN SKILLED AND LICENSED IN THIS PARTICULAR TRADE. 2. PROVIDE SPRINKLER SYSTEM TO NFPA 13 SPECIFIC HAZARD OCCUPANCY REQUIREMENTS. ANY DEVIATIONS THEREFROM MAY BE MADE AS REQUIRED BY INSPECTION AGENCIES, INSURING AGENCIES OR AS REQUIRED DUE TO INTERFERENCE WITH OTHER EQUIPMENT, STRUCTURAL MEMBERS, DUCTS, ETC. PROVIDE ADDITIONAL HEADS AS MAY BE REQUIRED FOR AN APPROVED SYSTEM. 3. RESPONSIBILITY FOR ELEVATIONS OF PIPING: A. CAREFULLY FIELD CHECK THE ELEVATIONS OF EXISTING GRADES AND BURIED SERVICE LINES AND MAKE A CAREFUL LAYOUT OF THE PROPOSED NEW SERVICES BEFORE STARTING WITH THE WORK, MAKING EVERY ATTEMPT TO AVOID INTERFERENCES. B. ATTENTION IS CALLED TO DUCTWORK, HEATING AND COOLING PIPING, WATER AND DRAJN PIPING, AND TO THE ELECTRICAL INSTALLATION, WHICH WILL BE INSTALLED BY OTHERS. C. ANY DISCREPANCIES OR CONFLICTS DISCOVERED SHOULD BE REPORTED TO THE ARCHITECT/IENGINEER, AND WORK SHALL NOT PROCEED UNTIL A SATISFACTORY RESOLUTION IS FOUND. NO ADDITIONAL COMPENSATION WILL SUBSEQUENTLY BE MADE TO THE CONTRACTOR BY THE OWNER TO COVER THE COST OF ANY SUCH INTERFERENCES, WHETHER DUE TO NEGLIGENCE, ERROR, OVERSIGHT OR OTHER CAUSE IN NOT HAVING PROPERLY ESTABLISHED THE ELEVATIONS OF ALL NEW OR EXISTING PIPING, ETC. 5. PIPING SHALL BE CONCEALED IN AREAS WITH CEILINGS AND EXPOSED IN AREAS WITHOUT CEILINGS. 6. PIPING SHALL BE INSTALLED AND SUPPORTED PER NFPA 13. 7. SLOPE PIPING IN ACCORDANCE WITH NFPA REQUIREMENTS. 8. WALL PENETRA11ONS THROUGH FIRE RATED PARTITIONS SHALL BE SEALED WITH PRO -SET 'FIRE STOP COUPLING" SYSTEM OR WITH GEDNEY TYPE CFS1 FIRE SEAL OR EQUAL SPACE BETWEEN SLEEVE AND WALL TO BE COMPLETELY SEALED WITH CAULKING. VOID BETWEEN SLEEVE PLUGS TO BE FILLED WITH INSULATION. CODES AND STANDARDS: ALL WORK SHALL COMPLY WITH NFPA REQUIREMENTS, 2020 FLORIDA BUILDING CODE, FLORIDA FIRE PREVENTION CODE (7TH EDITION), LIFE SAFETY CODE - NFPA 101 (2018 EDITION), NFPA 1 (2018 EDITION), AUTOMATIC SPRINKLER SYSTEMS - NFPA 13 (2016 EDITION) AND THE NATIONAL FIRE ALARM CODE - NFPA 72 (2016 EDITION), NFPA 99 (2018 EDITION). THE EN11RE SYSTEM AND ALL COMPONENTS LISTED HERON SHALL MEET ALL STATE, COUNTY, AND LOCAL CODES AND ORDINANCES IN EVERY RESPECT. THE CONTRACTOR SHALL OBTAIN ALL REQUIRED PERMITS, INSPEC11ONS AND PAY ALL FEES. SYSTEM DESCRIPTION: CONTRACTOR SHALL REVISE EXISTING SPRINKLER SYSTEM AS REQUIRED FOR THE NEW LAYOUT INCLUDING NEW PIPING FOR NEW OR RELOCATED SPRINKLER HEADS TO PROVIDE FOR PROPER COVERAGE. ALL HEADS ARE TO BE CENTERED IN THE CEILING TILES. DRAWINGS FOR APPROVALS: BEFORE PROCEEDING NTH WORK, THE CONTRACTOR IS TO PERFORM SYSTEM HYDRAULIC CALCULATION, SYSTEM LAYOUTS, PROVIDE AND SUBMIT SIGNED AND SEALED SHOP DRAWINGS FIRST TO THE AUTHORITY HAVING JURISDICTION, AND THEN TO THE ARCHITECT/ENGINEER FOR REVIEW. SUBMITTALS SHALL SHOW LOCATIONS OF PIPING, SPRINKLER HEADS, ETC., AND SHALL INCLUDE INFORMATION ON VALVES, SPRINKLER HEADS, ALARM VALVES, ETC. AT LEAST TWO (2) SETS OF THE SHOP DRAWINGS SHALL BEAR THE APPROVAL STAMP OF THE LOCAL FIRE MARSHALL. EQUIPMENT AND MATERIALS. ALL DEVICES, EQUIPMENT AND MATERIALS SHALL BE NEW, SHALL BE IN ACCORDANCE WITH NFPA REQUIREMENTS AND SHALL BEAR FACTORY MUTUAL AND THE UNDERWRITER'S LABEL OF APPROVAL ABOVE GROUND PIPE AND FITTINGS: PIPE ABOVE GROUND AND "THIN THE BUILDING SHALL BE STANDARD WEIGHT, SCHEDULE 40 BLACK STEEL PIPE OR APPROVED SEAMLESS THIN WALL BLACK STEEL PIPE CONFORMING TO ASTM A53. PIPE FITTINGS SHALL BE OF A TYPE APPROVED FOR SPRINKLER SYSTEMS AND DESIGNED FOR 175 PSI WORKING PRESSURE. MALLEABLE [RON STANDARD WEIGHT FITTINGS WILL BE ACCEPTABLE IN SIZES UP TO 6'. MECHANICAL PIPE COUPLINGS (ROLLED OR CUT GROOVED) MAY BE USED WHERE ALLOWED BY AUTHORITY HAVING JURISDICTION. SPRINKLER HEADS: FOR ALL EXPOSED UNFINISHED AREAS SPRINKLER HEAD SHALL BE A VIKING MICROFAST MODEL M QUICK RESPONSE UPRIGHT, 1/2' ORIFICE, BRASS FINISH. CONCEALED SPRINKLER HEADS SHALL BE VIKING, 5.6K, 1/2- ORIFICE, COLOR BY ARCHITECT. PROVIDE CONCEALED HEAD WITH PLATE. FIRE PROTECTION GENERAL NOTES ALL PIPING TO BE TESTED AT 200 PSI FOR A MINIMUM OF 2 HOURS. HYDRAUUC CALCULATIONS DESIGN CRITERIA: OFFICES / HALLWAYS: A. UGHTHAZARD OCCUPANCY B. SYSTEM TYPE: WETSYSTEM C. DENSITY. 0.10 GPM/SQ. FT. FOR 1500 SQ. FT. D. COVERAGE PER SPRINKLER: 225 SQ. FT. MAXIMUM E. TEMPERATURE RATING: ORDINARY TEMPERATURE F. MAXIMUM SPRINKLER SPACING: 15'-0* SPRINKLER INSTALLATIONS SHALL BE IN STRICT ACCORDANCE NTH THE NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) 13 SPRINKLER SYSTEMS, FIRE MARSHAL'S OFFICE, OWNER'S INSURANCE CARRIER, ALL LOCAL, STATE, FEDERAL CODES AND REGULATIONS AND ANY OTHER AUTHORITIES HAVING JURISDICTION OVER THIS PROJECT. ALL PERMITS REQUIRED IN CONNECTION NTH THIS SPRINKLER SYSTEM SHALL BE OBTAINED AND PAID FOR BY THE SPRINKLER CONTRACTOR. COORDINATE ALL PIPE ROUTING WITH ALL OTHER TRADES TO AVOID DUCTWORK, LIGHTING, PIPING AND ANY BUILDING STRUCTURE. ROUTE ALL PIPING CONCEALED ABOVE CEILING, WITHIN CHASES OR CONCEALED WITHIN WALLS. FIRE PROTECTION CONTRACTOR SHALL THOROUGHLY INVESTIGATE THE SITE BEFORE BIDDING. NO CHANGES SHALL BE ALLOWED IN CONTRACT PRICE FOR WORK REQUIRED TO COMPLY NTH EXISTING CONDITIONS. ALL EQUIPMENT SHALL BE UL AND FM LISTED AND LABELED. MANUFACTURER SHALL BE EQUAL TO GRINNEL, VIKING. BRANCH LINES PIPING TO BE SCHEDULE 40 BLACK STEEL PIPE JOINED WITH THREADED OUTLET FITTINGS. ALL SPRINKLER DROPS TO BE 1" SCHEDULE 40 NTH 1- X 1/2- THREADED REDUCER. HANGERS TO BE SIZED AND SPACED IN ACCORDANCE NTH NFPA 13. PROJECT SPECIFICATIONS TAKE PRECEDENCE OVER PLANS. APPROVAL FROM OWNER'S INSURANCE CARRIER IS CONTRACTOR'S RESPONSIBILITY. CONTRACTOR TO BASE ALL CALCULATIONS UPON CURRENT FLOW TEST SUPPLIED BY FIRE SPRINKLER CONTRACTOR. ALL SPRINKLER HEADS SHALL MATCH EXISTING SPRINKLER HEAD TYPES FOR LIGHT HAZARD OCCUPANCIES, INSTALLED IN FULL ACCORDANCE NTH MANUFACTURER'S GUIDELINES (REFER TO FIRE SPRINKLER LEGEND). THESE PLANS ARE CONCEPTUAL IN NATURE PER FLORIDA STATUTE 61 G1 5-30. CAMPBELL + VAN DUSEN IIARCH ITECTU RE IN-ER10F D1E31r3N www.CVDstudio.com CAMPBELL + VAN DUSEN Design Studio, LLC. 255 South Orange Avenue Suite # 1240 Orlando, Florida 32801 Phone: 407.930.6016 FL. Lic. No. AA26003339 ARCHITECT OF RECORD FRANK W. CAMPBELL AIA FL LIC NO. AR001 6053 COPY OF THIS PLAN IS NOT VALID UNLESS SIGNED, SEALED AND DATED BY THE ARCHITECT OF RECORD N x 0111111//// I �, S .. m E e-% . . ...... .......... ENS N 0.90018 STPTE OF f 0 PLO R\Q N ................. at lip; 0 N A\. \\\ /001111110 -L Taylor J. Lewis, PE, FL Reg. No. 90018 COPY OF THIS PLAN IS NOT VALID UNLESS SIGNED, SEALED AND DATED BY THE ENGINEER OF RECORD PROVIDE BUILDING MANAGEMENT WITH EXTRA STOCK OF NEW SPRINKLER HEADS AS REQUIRED BY NFPA 13 (2016 ED.). RELIABLE AND TYCO ARE EQUAL Lj_ PAINTING AND STENCILING: PROVIDE PAINTING AND STENCILING OF ALL EXPOSED PIPING, EQUIPMENT, ETC. INSTALLED AS PART OF THIS CONTRACT. TEST OF COMPLETED SYSTEM: 0 n ABOVE GROUND PIPING: PERFORM A HYDROSTATIC TEST OF THE PIPING SYSTEM IN LU ACCORDANCE WITH THE REQUIREMENTS OF NFPA 13 (2016 ED.). NOTIFY THE ARDilTECT/ENGINEER/OVMER/AJNDERWRITER PRIOR TO PERFORMING c < > THE TEST WHO, AT THEIR OPTION, MAY DESIRE TO WITNESS THE TEST. TEST Le) U_j LU I SHALL BE SATISFACTORY TO THE ARCHITECT, ENGINEER, OWNER, UNDERWRITER OR 0 co AUTHORITIES HAVING JURISDICTION. + IF TEST PROVES UNSATISFACTORY, LEAKS SHALL BE REPAIRED AND A NEW TEST Cie < SHALL BE PERFORMED. NO BACK FILLING SHALL BE DONE OVER BURIED JOINTS LLj LJLJ 0 UNTIL PIPE HAS BEEN PROVEN WATER TIGHT. SECURE PIPING IN PLACE PRIOR TO > TESTING. 0 m LU cl- _0 'o Lo AFTER TESTING HAS BEEN COMPLETED, ALL VALVES SHALL BE LEFT IN THEIR W cl- < 3:: rL-U4 or-2 ((y`13 RESPECTIVE NORMAL POSITIONS, AND THE OWNER AND HIS DULY APPOINTED REPRESENTATIVE SHALL BE INSTRUCTED IN THE CARE, OPERATION AND MAINTENANCE OF THE ENTIRE SYSTEM. MATERIAL AND TEST CERTIFICATE SHALL BE COMPLETED AND TURNED OVER TO THE OWNER'S REPRESENTATIVE UPON COMPLETING THE TEST. WATER SUPPLY TREATMENT - WATER SUPPLIES AND ENVIRONMENTAL CONDITIONS SHALL BE EVALUATED BY OMER FOR THE EXISTENCE OF MICROBES AND CONDITIONS THAT CONTRIBUTE TO MICROBIOLOGICALLY INFLUENCED CORROSION (MIC). WHERE CONDITIONS ARE FOUND THAT CONTRIBUTE TO MIC, THE OWNER SHALL NOTIFY THE SPRINKLER CONTRACTOR AND A PLAN SHALL BE DEVELOPED TO TREAT THE SYSTEM USING ONE OF THE METHODS AS ESTABLISHED UNDER NFPA 13 (2016 ED.). CONSTRUCTION DOCUMENTS 03.24.2023 PTION PRINCIPAL IN CHARGE F. CAMPBELL .................................................................... PROJECT MANAGER M. TORRES .................................................................... ADVENT HEALTH WELL 65+ ZEPHYRHILLS 22-0328-01 MEP CONSULTING FIRE PROTECTION ENGINEERS SINCE 1977 SPECIFICATIONS FL REG NO. 3089 2016 ALDEN RD. ORLANDO FL ,3280i (407) 246-1688 WWW.PBFLA.COM FP1 PEI PROJECT lk *1 22121 rio 3 2 7 5 4 9 6 7 1; 4� A 4,- 4 A 4 - - - - - - - - - - - - - - - - -- - - - "77; 0 M:mr-wm W11111111 M Mi m m! m m M Wo ml i��m Wo 0:1WIIIIIII 0 0 0!0 M 0 WWO 0 1111111 10:0 m!W1111111 oil =I 'MIM! *imimim WWI 0!0 m m 0 W1 ................... F ............................. .. 7 . ..... . ...... . . ....... F—:— .......... . ..... .. ..... ..... . F-7 7 7 —1 ...... ............... ELEC. ROOM/ .. ......... ..... ................... FIRE RISER ......... ..... .. .. ............................... ........ ....... ............ m ......... ........ ......................... ... ... ...... . m . ....... ...... .................... ..... m m .............. ........... .............. WELLNESS S:U TE W�LLNESS'SUI E WELLNESS'SUI�E '':''WELLNESSSUItE, ....... ....... 5 6 7 8: CONSULT ROOM ................... WELLNESS: SUITE . ..................... .. ........... ...... ................. . ................... .......... .. ............. ........... ... ....... ............... 4... ....................... .............. ... ... ....... ....... ...... ................... ........ ..... ....... ...... ........... CARE ......... . L: --- — — — — — — — — — -i L — — — — — — --- — — - J L� . ............... ...... COORDINATORS . ............... ...... ............................. .............. ......................... ............................................................. CORRIDOR F- --VYEtL-NM'.SLjtT-E 7 r ....... ................ ........ 3 ...... :'CORRIDOR ... .. ................... ......................... ................ ............. ...... �j 1.25 .. ......... ......... ....... ...... ............... ... q ....... ........... . ....... .............. ................... PRACTICE :AD MINISTRATOR ........ ...................................... ................ .................. ....... .......... .................. .................. .......... ....... .......... .......... ................... 133 ............. .................. ............................ ............. ......... 1110 .... WELLNESS SUITE ... I' ............. ............ 2 ..... .......... ... .............................. . . . ............ . . ..................... .... ........ -L.: — — — — — — --- — — -- ........... ......... ... ........ .. ..... ................ ................... STORAGE T ...... -S 17� ............................ . ..................... .................. ......... ..................................................... .......... ............................................................................ ...... . ................ .......... BREAK ROOM .......................................... ............ ................. ........................................ A., KV- ......... ... a. ......... ......... ....... ................. ............... ........................ ............ . LET TOILET I I : ....... : ... : ............... . ....... ........... TOI ............ ........... ........ .......... ....... ....... ............... ....... . ....... ....... . ........ . ............. LOBBY ........... ........................................... ........ .. . ................ ...... ....... ............... ............... F 01 L ............... . — — — — — — — — - ............ 5-12 SF ....... ....... . .................... COMMUNITY ............ . ................ ....... . ....... ....... .............. ................. ...... ..... ....................... ...... ............ ......... ...... ..................... ................... ............. ........ ... .......... ........ ................... .................... ................ . a ............. ......... ....... ....... 396 SF ..... . ....... . ....... . ....... ...... ....... —7 . ....... .......... . ....... . ............... . ....... ....... . ........ ............ . ............. ...... ........ ....... .............. . .............................................................. ............. ........ ........ — .................. ........... — — — — — — — — — — -- — — — — — — — — -- — — — -- — — — — -- 71 1— 1 W H --- — --- --- — A :A- 4. r %4� 4 . . — I A t A 4 A A 4- 4'A r A: V A -A A' -:A .4- L A �A —J -:J 7 1z A A z A -A A All 'A 4- % '4 A A A' A A W' .4A FIRE PROTECTION RENOVATION PLAN 1/411 = 1 1-011 B C C - -- Do OE OF bG HYDRAULIC CALCULATlONS DESIGN CRITERIA: OFFICES / HALLWAYS: A. LIGHT HAZARD OCCUPANCY B. SYSTEM TYPE: WET SYSTEM C. DENSITY- 0.10 GPM/SQ. FT. FOR 1500 SQ. FT. D. COVERAGE PER SPRINKLER: 225 SQ. FT. MAXIMUM E. TEMPERATURE RATING: ORDINARY TEMPERATURE F. MAXIMUM SPRINKLER SPACING: 15'-0" E VIEW EATE CITY OF ZEPHAY LiU-S FIRE AND LIFE WM ALL WORK SHALL COMPLY WITH NFFA CODES AND STANDARDS CAMPBELL + VAN DUSEN ARCH ITECTU RE It-A—ERIOF DIE31riN www.CVDstudio.com CAMPBELL + VAN DUSEN Design Studio, LLC. 255 South Orange Avenue Suite # 1240 Orlando, Florida 32801 Phone: 407.930.6016 FL. Lic. No. AA26003339 ARCHITECT OF RECORD FRANK W. CAMPBELL AIA FL LIC NO. AR001 6053 COPY OF THIS PLAN IS NOT VALID UNLESS SIGNED, SEALED AND DATED BY THE ARCHITECT OF RECORD ON11111111/j/ .................. C E jyg, No. 90018 STATE OF Ar ZZ 4 �oe ... ..... C4 z �04'/; 01VAL `7t _j Taylor J. Lewis, PE, FL Reg. No. 90018 COPY OF THIS PLAN IS NOT VALID UNLESS SIGNED, SEALED AND DATED BY THE ENGINEER OF RECORD __j U- Vi __j __j 0 LU < Q C/) LU U-1 > I c) co + LO --.0 < LU LU 0 > 0- 0 Uj -,o Lo W < 3:: P2 CL PU-j4 Cvt), CONSTRUCTION DOCUMENTS 03.24.2023 I DI Wto] U I a I Lei I PRINCIPAL IN CHARGE F. CAMPBELL .. ................................................................. PROJECT MANAGER M. TORRES .................................................................... ADVENT HEALTH WELL 65+ ZEPHYRHILLS 22-0328-01 MEP CONSULTING FIRE PROTECTION ENGINEERS SINCE 1977 RENOVATION PLAN FL REG NO. 3089 2016 ALDEN RD. ORLANDO, FL 32803 (407) 246-1688 WWW.PEIFLA.COM FP291 PEI PROJECT it 22121