Loading...
HomeMy WebLinkAbout37827 Eiland Blvd (2)3.W A-R III - DI ELBOW FIRE PROTECTION GENERAL SYSTEM NOTES WELDED OUTLET OR MECHANICAL TEE RING TYPE PIPE HANGER SPRINKLER SRANCHLINE ` I� NEW CEILING 1" STEEL PIPE ,-. yr THREADED REDUCER RECESSED SPRINKLER HEAD ESCUTCHEON RECESSED PENDENT SPRINKLER HEAD - SCALE: NO SCALE WELDED OUTLET, MECHANICAL TEE OR THREADED FITTING ,•• INLET NIPPLE ewuaaa elu+e..ne /-FLEXIIBLE BLIC RAIDED FLEX STEEL 4 / 1" NOMINAL DIAMETER ,/ NUT BRACKET CEILING GRID----'* t�•.I *4 NEW CEILING ESCUTCHEON PENDENT SPRINKLER HEAD l - VICTAULICFLEXIBLE BRAIDED HOSE -- SCALE: NO SCALE SPRINKLER BRANCHLINE UPRIGHT SPRINKLER HEAD - SCALENO SCALE SWING -JOINT BEAM CLAMP - 11- - .. i ,I -BAR JOIST r: INNI'M FJW HANGER 1 BRANCH LINE HANGER DETAIL - - SCALE: NO SCALE I Flexible Drop- _ (Typical) Main Wer- -Pendant Sprinkler (Typicol) Hall F Storage Shared Document Area 1 Work Room Cross Section 1/8" Scale Ceiling Heights Are 9'-0" U.N.O. Al Rise -- - ---- - - - - - Clean U81ty - - - -7-- --� - - -- ----- -- ,i MEP - - -y -- -- Stor cal General Nurse CMO I 1 Recgivi - _ Work Room ; Gonflrence Room n0! - - �= Extended Team Area 1 - I I ' Wc s - �� 1 - • • s s ! • a , I II I I , I _ • tr•o tr• r i e•t ne ' - a ` r t f7Sto. Me uip 9e 1� {� ------ - - a-• -- lam! i I LL I ' d Eq , � Malty @ lI , _ i gall E Main 4 10' A.=.F. i I - .- - - � Hal E ,K IA p 1% • 1% 1% 1% 114 - • ,% - Q• ,% , 0 ,% �� • II q -- , ra ra tr-4 . ,xo ue ua n 1° - t1y sxe""---�` r-o ts� �'- - Shared Miedicbl Apts. 2 • 1 J_` 4Branch Lines (& 1C'-)" A.F.F. ,>_- _ - -- - -- - I _ _ --- - - -- - - -- -- - 1 lTypicd) -- - - Med(cation, " ---- - Consutt 3 I r - -- - ( j . _ I Audio - --- - ' _ ..--- - - - Comm.--- --- - - - _ Si 1% 1K -+- - 1% 1K 1 1K I - - - - ra z r t _ _ V.2 ---- v • • Exam 7 � • . , �s•t0- - - _- t � • - � ; • -- t - f ua • r.t i r I rt - isa- I WW r 1 - - -- e - - - - - -- , W omen s Health - - - - - L T le-Heatih 1 �-----�:•, IExarnB ` -�.-- - ---- - t E %, -'s�� -- I -- -_I - -- - - Lob /Blood t Exam 6 �� 4 �' t _� - - , ! r - - - -- ♦ - r% r --- - - - Hall t- n ra r • r -5 =fie+- i lit � b - _Arz net 619-mT ZJ We 7 lcal - --- -- a- -- - - Tele-Health '` - - ---- - r -.-. ornult _ I I, Exam 9 - •p - --- _ 1% consult 2 1 1% Urine -a rB t a 8 rB r ,rod ��'r:v a-„ r•n • Shared DocumentA ea _ • - Shared Document Area 2 Exam $ Exam 3-- --- -- - , _ ~ t Hall D I -- I _ -- - % -- • t`r - i - _ _ T -- -- -- - - -- rwilt 4 - --- xam 10 • -- - - - -� f �1 • �� - �. _- T ,. T Exam 4 ':•... I - COnsi1 , - - - - .� r•10 Ta. Jan. - - }J t We 6 OP t - - mr� _.� rc s-2 I atl r4 a ra r8 rB ra ra , We 8 ° _ Cy 'Work Rm/ Storage Hydraulic Information OCCUPANCY CLASSIFICATION i-DENSITY (gpm Light Hazard 0.10 for 1500ftl (Actual 959ft2) QUICK RESPONSE REDUCTION 9'-0 Ceiling (40.0%) 900ft2 TOTAL HOSE STREAMS 100.00 TOTAL HEADS FLOWING 8 K-FACTOR 5.6 TOTAL WATER REQUIRED 257.14 TOTAL PRESSURE REQUIRED 56.242 BASE of RISER (gpm) 257.14 BASE of RISER (psi) 56.242 SAFETY MARGIN (psi) +8.112 (12.6%) Light Hazard■0.10aom/ft2 for 959ft2 • lWC I y We 2 ,'G _T - -_ - Exom 2 a�-i -� s , I �?�'o Chec In Q _ • , - HOI':�1%--------------------f--f--- - - -- - - 1.$ Rise' Mn I l I F.M. L --- r n1h4 Storage 3 • , b 'Storage 4 t1i �; tr ra 7-11 1,zB nB e r Help Desk K ,K 1% 1 1K 1'iS , • • r� r.+ ,r•n rs a ,r-tB ra -+,� 3 I • i I � b •0• !,Storage -_'' - - - - - - - ra Waiting Room 1 . 20'-3,. per NFPA 13 201E Section 11.2.3.2.3.1: There is a 40.0% decrease in Mn2 1::FDM. design area for quick response sprinklers 9'-0" ceilings - �! PT 11500 Sri It x 0.60 = 900 Sri .ft. Ha11 G Mh$ I --AL AL AL A r� r Shared Medical Group Therapy Rm. I n A X Air Vent I , Mh3 Mh6 tz•to • ua tz-,B I ra A e r• 1X 1% • 4 I _ I- qr Sprinkler Legend Symbol I SIN Model Quantity K-Factor Type Size Response Finish Temperature Note 1414I F1 FR56 145 5.6 Pendent % Quick White 155OF RELIABLE 15 G5-56 1 5.6 Pendent % Quick White 155°F REUABLE RA1425 F1FR56 91 5.6 Upright 1h Quick Brass 2001F RELIABLE Total =155 - -Floor Plan 1/8" Scale 11i 1% IV. 1% VA 1X , 4'•N 17.4 1ri na 1 7'10 t 7•2 1.5" Rise ', V-4 1 Armory `R 11% ly IV. bill • V4' I ra rs - 9 r1 %O I Vestibule I�7 i- L V� d security it -_4 - -- i -- -C^ - - i---_-- Storage 1 ( r4 1 Holding Rm. - l SPARE PARTS INVENTORY QTY. SCOPE OF WORK REVISIONS SIN, K-FACTOR, SSU/SSP/SSS, TEMP # PROVIDED, INSTALLED, OR PERFORMED BY: BEACH LAKE OTHERS REV# DATE DESCRIPTION EXCAVATING AND OR BACKFILLING X REV# MM-DD-YYYY SHORT DESCRIPTION CUTTING - PATCHING X FIRE STOPPING X PAINTING OF PIPE - EQUIPMENT X ALARM WIRING X ALARM SUPERVISORY I X AIR COMPRESSOR WIRING X HEAD WRENCH: # FIRE EXTINGUISHERS I X I NOTES: NOTES: NOTES: Hydraulic Information OCCUPANCY CLASSIFICATION Light Hazard DENSITY (gpm/ft2) 0.10 for 1500ft2 (Actual 1523li TOTAL HOSE STREAMS 100.00 TOTAL HEADS FLOWING 13 K-FACTOR 5.6 _ TOTAL WATER REQUIRED 363.32 TOTAL PRESSURE REQUIRED 54.497 BASE of RISER (gpm) 353.32 BASE of RISER (psi) - -- 54.497 SAFETY MARGIN (psi) - +9.340 (14.6%) Light Hazard■0.10gpm/ft2 for 1523ft2 1. PROJECT DESCRIPTION AND APPLICABLE CODES. NFPA 13 2016 2. SCOPE OF WORK: INSTALL NEW WETABOVEGROUND FIRE SPRINKLER SYSTEM. 3. WATER FLOW DATA FLOW TEST: DATE: 3-16-2021 BY: ZEPHYRHILLS UTILITIES DEPARTMENT STATIC: 65 PSI RESIDUAL: 55 PSI FLOW: 1,130 GPM 3. FIRE PUMP INFORMATION: NO PUMP. 4. SPECIAL NOTE(S): NONE. 5. HANGERS AND SPACING PER NFPA-13 2016 EDITION STANDARDS. 7. FIRE SPRINKLER SYSTEM(S) TO BE TESTED PER NFPA-13 2016 EDITION STANDARDS. 8. ALL FIRE SPRINKLER PIPING 1-1/4" OR LARGER TO BE UL LISTED LIGHT WALL BLACK STEEL PIPING WITH GROOVED FITTINGS. ALL FIRE SPRINKLER PIPING SMALLER THAN 1-1/4" TO BE UL LISTED SCHEDULE 40 BLACK STEEL PIPING WITH THREADED FITTINGS. 9. LOW POINT DRAINS WILL BE ADDED WHEN REQUIRED. 10. BEACH LAKE SPRINKLER IS NOT RESPONSIBLE FOR THE FOLLOWING: - 24 HR SYSTEM SUPERVISION. - ANY CHANGES TO WATER SUPPLY OR WATER CONDITIONS. -ANY ALARM SYSTEM AND/OR DETECTION SYSTEM WORK. -ANY ELECTRICAL POWER AND/OR POWER WIRING. 11, PROPERTY OWNER OR DESIGNATED REPRESENTATIVE SHALL ENSURE THAT WATER -FILLED PIPING IS MAINTAINED ATA MINIMUM TEMPERATURE OF +40 DEGREES FAHRENHEIT (+4 DEGREES CELSIUS) TO PROTECT FROM FREEZING. 12. PROPERTY OWNER OR DESIGNATED REPRESENTATIVE IS RESPONSIBLE FOR MAINTAINING FIRE SPRINKLER SYSTEM PER NFPA-25 STANDARDS. Spare Head Box 6" Electric Bell ijV11Ired By Others) 3" Water Flow Detector (Wired By Others) 3" Riser Check Valve (With Gauges) (� 3" FDC Line 3" Control Valve 4" To Yard FDC (See Site Plan) /+ ALL. WORK SHALL COMPLY WITH NFFA CODES AND STANDARDS REVIEW DATE / CITY OF ZEPHYR FIRE ANO LIFE SMETY EXWINE Gl.. -Riser Detail 1/8" Scale E N VA Clinic BY 37827 Eiland Blvd. ## YMSt10TASTAMP Zephyrhills, FL 33542 W E NICET -- -- --- - -- - - FIRE PROTECTION PLAN - S DRAWN: NK DATE: 5-4-2021 SHEET No. F 1 REVISION: JOB #: DRAWING SCALE , (UNLESS NOTED OTHERWISE) Beach Lake Sprinkler 2 1 0 4 8 BEACH LAKE Fire Protection Services S P R I N K L E R 19094 Treverton Ill 04 Y FIRE PROTECTION SERVICES Brooksville, FL Phone:352-799-292990 SCALE 118"=V-0" www.boachlakospdnkler.com -Z�� 3 Z js'� C 3" Rise To System 1" Inspector's Test With Relief 1.5" Main Drain Dr. Michael D. Wilburn, P.E. LICENSE #76067 LOCAL ENGINEERING, INC. 8427 E. ROSKO CT. FLORAL CITY, FL 34436 Michael Digitally signed by Michael Wilburn Wilburn Date: 2021.05.11 18:37:33-04'00' 0 ON .� CEN,3,k- �G V. _ No. 76061 2 _ 0 STATE OF < ORIO P- �N /ONAL //0111100\\ 6 16' i • • • • • • • • • • • • • • • New 8" Wet Tap With Sleeve (By Others) • • 8 • 4'-9.9 • i :• Flow Test: Conducted by: Zephyrhills Utilities Department Date: 3-16-2021 •: Static: 65 PSI Residual: 55 PSI L Flow: 1,130 GPM O • I Existing Hydrant #8151 10 \� : Sprinkler Legend Symbol SIN Modell Quantity K-Factor Type_ Size Response Finish Temperature Note �1414 F1FR5C 145 5.6 Pendent % Quick White 155°F iRELIABLE 3415 G5-561 1 5.6 Pendent 1/2 Quick White 155'F RELIABLE 1425 F1FR56 9 5.6 Upright 1/2 Quick Brass 20011F RELIABLE Total a 155 Hydraulic Information OCCUNNCr CLASSTICATpN L"NS1A1! D6MUTr IIInV6'1 O. tO lw I WqY IAclwl S6Bn WICh NSP'011fil R91—TiON S-4C `I nO1-6M1 S0011' TOTA..I .—I ,NN IOTA, N & FLO— S —Al TOIt 6.5 - TOTA'_WATINIQW.D �71T.1!- TOTAL. MI6/L6t! NW61!D 14467 SA37 d Welt lOpnl �' ]n 1. BA6f d AISEA Ip.11 lS.IAI AAPE rY S1AItOM Ip.II .Atl]117 SKI [a0p IDYpmllt' IS6Sro 11 a NInA1]]61SlacllOn ll.]3.7,3. t. TMIP ,YAMYY OSclu3. in <IOYIYn a�w IOr qulgY i.3{gnAS YgInYNIIT-0" I tS00 nq N .O S0. SOD .q.N.l C-nnp Parking Lot Eiland Blvd Site Plan — 1/20" Scale 4 15'-0 New Yard FDIC Per AHJ Requirements (By Others) New 4" FDC Line (By Others) Parking Lot 133'-0 New 6" Fire Line - (By Others) New Hydrant (By Others) New 8" Water Main �\ (By Others) New 6" DDCVA Per AHJ Requirements (By Others) • 8 r-0 New 6" Fire line (By Others) New 8" Water Main (By Others) GENERAL UNDERGROUND NOTE: ( _ Underground Main, Hydrants and Valves are Shown For Calculation - Purposes Only. See Utility Plan For Entire Underground Installation. - Underground Installation Is Assumed To Be installed, Flushed and --a- — 1 . Test Per NFPA 24, And Approved By the AHJ. Hydraulic Information OCCIMWVC WICATION LISM haaar! 01101 TI _tM.NM�WIt� - TOTX. NO66 In SAMS -- ---. 10 . T. TOTA, ADS W N-PAT.TdI 6A TOTAL VMTe11 ft WIND 30.32- TOTAL MSS6. SSOUNO - M.3lI YM of MSeNI ) .. S0142 --- — aN101111NA1 II MS1T - SAIltt MAaDS1 pI) -... N.SS6ItI S%r — SPARE PARTS INVENTORY QTY. SIN, K-FACTOR, SSU/SSP/SSS, TEMP # HEAD WRENCH: # NOTES' SCOPE OF WORK REVISIONS DESCRIPTION PROVIDED, INSTALLED, OR PERFORMED BY: BEACH LAKE OTHERS REV# DATE EXCAVATING AND OR BACKFILLING X REV# MM-DD-YYYY SHORT DESCRIPTION CUTTING - PATCHING X FIRE STOPPING X PAINTING OF PIPE - EQUIPMENT X ALARM WIRING X ALARM SUPERVISORY X AIR COMPRESSOR WIRING X FIRE EXTINGUISHERS X NOTES: NOTES: Parking Lot New 8" Water Main (By Others) FDIC Per AHJ Requirements (By Others) 6" OSBY Gate Valve With Tamper Switch (Wired By Others) 6" Flanged 90 1 6" DI Stut 6" To Building 90 Elbow 4" Check Valve — V�n rrl C r1r+ r1o+ m i 1 No Scale 6" Wilkins 350DA Or Equivalent (By Others) 6" OSBY Gate Valve With Tamper Switch (Wired By Others) Flanged 90 Elbow N Stub Up 6" From Municipal —Backflow Preventer Detail No Scale R ENGINEERING, INC. N VA Clinic BY 37827 Eiland Blvd. THISIS NOT A STAMP Zephyrhills, FL 33542 NICET W x.-. E - FIRE PROTECTION PLAN - S DRAWN: NK [DATE: 542021 SHEET No- FP 2 REVISION: JOB 0: DRAWING SCALE ! (UNLESS NOTED OTHERWISE) Beach Lake Sprinkler 2 1 0 4 8 BEACH LAKE Fire Protection Services S P R I N K L E R 19094 Treverton Ln. (61 Brooksville, FL 34604 FIRE PROTECTION SERVICES Phone: 352-799-2990 SCALE 118"=V-0" www.boachlakespdnkler.com Dr. Michael D. Wilburn, P.E. LICENSE #76067 LOCAL ENGINEERING, INC. 8427 E. ROSKO CT. FLORAL CITY, FL 34436 Michael Digitally signed by Michael Wilburn Wilburn Date: 2021.05.11 18:37:13-04'00' \�\\111111/// .� DON �. ocENsF . �4 No. 76061 2 STATE OF /ONAL �� \ /////1111111\\�